ML16341E951
| ML16341E951 | |
| Person / Time | |
|---|---|
| Site: | Diablo Canyon |
| Issue date: | 12/28/1988 |
| From: | Yuhas G NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V) |
| To: | Shiffer J PACIFIC GAS & ELECTRIC CO. |
| Shared Package | |
| ML16341E952 | List: |
| References | |
| NUDOCS 8901180208 | |
| Download: ML16341E951 (6) | |
See also: IR 05000275/1988033
Text
REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
'CESSION NBR:8901180208
DOC.DATE: 88/12/28
NOTARIZED: NO
DOCKET
FACIL:50-275 Diablo Canyon Nuclear Power Plant, Unit 1, Pacific
Ga
05000275
50-323 Diablo Canyon Nuclear Power Plant, Unit 2, Pacific
Ga
05000323
AUTH.NAME
AUTHOR AFFILIATION
YUHAS,G.P.
Region 5, Ofc of the Director
RECIP. NAME
RECIPIENT AFFILIATION
SHIFFER,J.D.
Pacific Gas
& Electric Co.
SUBJECT:
Forwards Insp Repts
50-275/88-33
& 50-323/88-31
on
I
881219-20.No violations noted.
DISTRIBUTION CODE:
IEOSD
COPIES
RECEIVED:LTR
l
ENCL j
SIZE: 2. +
TITLE: Environ
& Radiological
(50 DKT)-Insp Rept/Notice of Violate.on
R spons
S
NOTES
RECIPIENT
ID CODE/NAME
PD5
LA
ROOD, H
INTERNAL: ACRS
NMSS/LLOB
5E4
NRR/DLPQ/PEB 11
NRR/DREP/EPB
10
NRR/PMAS/ILRB12
'GC/HDS2
RGN2/DRSS/EPRPB
EXTERNAL: LPDR
COPIES
LTTR ENCL
1
0
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
RECIPIENT
ID CODE/NAME
PD5
AEOD/DSP
NMSS/SGOB
4E4
NRR/DOEA/EAB 11
NRR/DREP/RPB
10
NUDOCS-ABSTRACT
5
FILE
01
RGN4 MURRAY,B
NRC PDR
RESL MARTIN,D
COPIES
LTTR ENCL
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1
S
NOXK 'ZO ALL RIDS"
RECZPIEtGS'IEASE
HELP US 'IO REDUCE HASTE!
QXKhCZ '%HE DOCGMEÃZ CON'ZROL DESKI
RXM Pl-37 (EXT'0079) I XXZMZNhTH RX3R MWE HEN DXBXSZHUTZGN
LTSTS MR DOCUMEWZS YOU DC@ST MKDl
TOTAL NUMBER OF COPIES
REQUIRED:
LTTR
25
ENCL
24
7
Docket Nos.
50-275,
50-323
Pacific Gas
and Electric Company
77 Beale Street
Suite
1451
.. San Francisco,
California 94106
Attention:
Mr. J.
D. Shiffer, Vice President
Nuclear
Power Generation
Gentlemen:
SUBJECT:
NRC
INSPECTION
OF DIABLO CANYON POWER
PLANT, UNITS 1 AND 2
This letter refers to the routine in-office inspection
conducted
by Mr.
W.
TenBrook of this office on December
19-20,
1988, of activities authorized
by
NRC License
Nos.
DPR-80 and
DPR-82 and to the discussion
of our findings held
by Mr. TenBrook with Mr.
D. Unger-at the conclusion of the inspection.
Areas
examined during this inspection are described
in the enclosed
inspection
report.
Within these
areas,
the inspection consisted of selective
examinations
of procedures
and representative
records,
interviews wi.th
personnel,
and observations
by the inspector.
No items of noncompliance with NRC requirements
were identified within the
scope of this inspection.
In accordance
with 10
CFR 2.790(a),
a copy of this letter and the enclosure
wi 11
be placed in the
NRC Public Document
Room.
Should you have any questions
concerning this inspection,
we will be glad to
discuss
them with you.
Sincerely,
O( ()(()Q.l 5i)ll6~
Gregory
P.
Yuhas, Chief
Emergency
Preparedness
and
Radiological Protection
Branch
Enclosure:
Inspection
Report Nos. 50-275/88-33,
50-323/88-31
cc w/enclosure:
S.
M. Skidmore,
PSkE
J.
D. Townsend,
Plant Manager,
PG8E
Richard
F.
Locke, Esq.,
POTE
D. Taggart,
Supervisor,
gA
News Services
T.
L. Grebel,
Regulatory Compliance Supervisor
State of California
890ii80208 88i228
ADOCK OS00027S
Q
bcc w/copy of enclosure:
, Docket File
Resident
Inspector
Project Inspector
G.
Cook
B. Faulkenberry
J. Martin
T. Foley,
S. Silver (report only)
bcc w/o enclosure:
M. Smith
LFMB
REGION V/jg
WKTenbrook
HSNorth
Ix/c7/I
i>>7/ff
GPYuhas
tK< /4
C"
R
UEST
COPY ] RE
UEST
COPY ]
COPY ]
/
NO
/
NO
YES /
NO
TO
YES /
NO