INDIANA AND MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revision: 24.0 Table:
4.1-12 Page:
1 of 2 UNIT 1 AND UNIT 2 - REACTOR COOLANT SYSTEM CODES1 Component Code UNIT 1 Addenda and Code Cases Reactor Vessel ASME III 2 Class A 1965 Edition through 1966 Winter Addenda, Code Cases 1332-2, 1358, 1339-2, 1335, 1359-1, 1338-3, 1336 Reactor Vessel Closure Head (RVCH)
Class 1 (RVCH) 1995 Edition through 1996 Addenda (RVCH)
Full Length Control Rod Drive Mechanisms ASME III 2 Class 1 1965 Edition through 1966 Winter Addenda 1995 Edition through 1996 Addenda (RVCH)
Steam Generators (OSG Model 51 Steam Dome Shell)
ASME III 2 Class A 1965 Edition through 1966 Winter Addenda Code Cases 1401 and 1498 Steam Generators (RSG Model 51R)
ASME III 2 Class 1 1989 Edition (No Addenda), Code Cases N-20-3, N-71-15, N-411-1, N-474-1, 2142-1, 2143-1, N-401-1, and N-416-1 Reactor Coolant Pump Casings No Code (Designed with ASME III 2 Article 4 as a Guide) 1968 Edition Pressurizer ASME III 2 Class A 1965 Edition through Winter 1966 Addenda, Code Cases 1401, 1459 Pressurizer Safety Valves ASME III 2 1968 Edition Power Operated Relief Valves B-16.5 Main Reactor Coolant System Piping B31.1 1 1967 Edition Reactor Coolant System Valves B-16.5 or MSS-SP-66, and ASME III 1968 Edition 2 1 Repairs and replacement for pressure retaining components within the code boundary, and their supports, are conducted in accordance with ASME Section XI.
2 ASME Boiler and Pressure Vessel Code, Section III-Nuclear Vessels
INDIANA AND MICHIGAN POWER D. C. COOK NUCLEAR PLANT UPDATED FINAL SAFETY ANALYSIS REPORT Revision: 24.0 Table:
4.1-12 Page:
2 of 2 UNIT 1 AND UNIT 2 - REACTOR COOLANT SYSTEM CODES Component Code UNIT 2 Addenda and Code Cases Reactor Vessel ASME III 2 Class A ASME III, Class 1 (RVCH) 1968 Edition (1968 Summer Addenda),
Code Cases 1335-4 and N-60-5 1995 Edition through 1996 Addenda Full Length Control Rod Drive Mechanisms ASME 2 Class 1 1995 Edition through 1996 Addenda Steam Generators ASME III 2 Class A 1968 Edition through Winter 1968 Addenda, Code Cases 1401, 1498 for upper assemblies and 1983 Edition through Summer 1984 for replacement lower assemblies Reactor Coolant Pump Casings No Code (Designed with ASME III 2 Article 4 as a Guide) 1968 Edition through Summer 1969 Addenda Pressurizer ASME III 2 Class A 1965 Edition through Winter 1966 Addenda Pressurizer Safety Valves ASME III 2 1968 Edition Power Operated Relief Valves B16.5 Main Reactor Coolant System Piping B31.1 1 1967 Edition Reactor Coolant System Valve B-16.5 or MSS-SP-66, and ASME III, 1968 Edition 2