Revision to Technical Requirements Manual
ML16298A386
Person / Time
Site: Susquehanna Talen Energy icon.png
Issue date: 10/18/2016
From:
Susquehanna
To: Gerlach R
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML16298A386 (40)


Text

Oct. 18, 2016 MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2016-35234 USER INFORMATION:

GERLACH*ROSEY M Address: NUCSA2 Phone#:

542-3194 EMPL#: 028401 CA#:

0363 TRANSMITTAL INFORMATION:

TO:

GERLACH*ROSEY M 10/18/2016 LOCATION:

USNRC FROM:

NUCLEAR RECORDS DOCUMENT CONTROL CENTER (NUCSA-2)

Page 1

THE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU.

HARDCOPY USERS MUST ENSURE THE DOCUMENTS PROVIDED MATCH THE INFORMATION ON THIS TRANSMITTAL.

WHEN REPLACING THIS MATERIAL IN YOUR HARDCOPY MANUAL, ENSURE THE UPDATE DOCUMENT ID IS THE SAME DOCUMENT ID YOU'RE REMOVING FROM YOUR MANUAL.

TOOLS FROM THE HUMAN PERFORMANCE TOOL BAG SHOULD BE UTILIZED TO ELIMINATE THE CHANCE OF ERRORS.

ATTENTION: "REPLACE" directions do not affect the Table of Contents, Therefore no TOC will be issued with the updated material.

TRMl -

TECHNICAL REQUIREMENTS MANUAL UNIT 1 REMOVE MANUAL TABLE OF CONTENTS DATE: 09/12/2016 ADD MANUAL TABLE OF CONTENTS DATE: 10/17/2016 CATEGORY: DOCUMENTS TYPE: TRMl of 2

Oct. 18, 2016 ID:

TEXT 3.11.2.6 REMOVE:

REV: 6 ADD:

REV: 7 CATEGORY: DOCUMENTS TYPE: TRMl ID:

TEXT 3.3.4 ADD:

REV: 10 REMOVE:

REV: 9 CATEGORY: DOCUMENTS TYPE: TRMl ID:

TEXT LOES REMOVE:

REV: 87 ADD:

REV: 88 Page 2

ANY DISCREPANCIES WITH THE MATERIAL PROVIDED, CONTACT DCS @ X3107 OR X3136 FOR ASSISTANCE.

UPDATES FOR HARDCOPY MANUALS WILL BE DISTRIBUTED WITHIN 3 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.

PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON COMPLETION OF UPDATES.

FOR ELECTRONIC MANUAL USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.

of 2

SSES MANUAL Manual Name:

TRMl Manual Title : TECHNICAL REQUIREMENTS MANUAL UNIT 1 Table Of Contents Issue Date:

10/17 / 2016 Procedure Name Rev I ssue Date Change ID Change Nulllber TEXT LOES 88 10/17 / 2016 Title : LI ST OF EFFECTIVE SECTIONS TEXT TOC 25 04 / 28 / 2015

Title:

TABLE OF CONTENTS TEXT 1.1 1

01/31 / 2014

Title:

USE AND APPLICATION DEFINITIONS TEXT 2.1 2

04 / 28 / 2015

Title:

PLANT PROGRAMS AND SETPOINTS PLANT PROGRAMS TEXT 2. 2 10 01/31 / 2014 Title : PLANT PROGRAMS AND SETPOINTS INSTRUMENT TRIP SETPOINT TABLE TEXT 3. 0 5

03 / 05 / 2015

Title:

TECHNICAL REQUIREMENT FOR OPERATION (TRO) APPLICABILITY & SURVEILLANCE (TRS)

APPLICABILITY TEXT 3. 1.1 1

11 / 09/2007 Title : REACTIVITY CONTROL SYSTEMS ANTICIPATED TRANSIENT WITHOUT SCRAM ALTERNATE ROD INJECTION (ATWS-ARI) INSTRUMENTATION TEXT 3.1. 2 0

11/1 8/2002

Title:

REACTIVITY CONTROL SYSTEMS CONTROL ROD DRIVE (CRD) HOUSING SUPPORT TEXT 3.1. 3 5

04 / 16 / 2009 Title : REACTIVITY CONTROL SYSTEMS CONTROL ROD BLOCK INSTRUMENTATION TEXT 3. 1. 4 0

11 / 18/2002

Title:

REACTIVITY CONTROL SYSTEMS CONTROL ROD SCRAM ACCUMULATORS INSTRUMENTATION &

CHECK VALVE TEXT 3.2. 1 17 03 /31/ 2016 Title : CORE OPERATING LIMITS REPORT (COLR)

Page.l of li Report Date: 10 / 17 / 16

SSES MANUAL Manual Name:

TRMl Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.3.1 0

11/18/2002

Title:

INSTRUMENTATION RADIATION MONITORING INSTRUMENTATION TEXT 3.3.2 3

03/31/2011

Title:

INSTRUMENTATION SEISMIC MONITORING INSTRUMENTATION TEXT 3.3.3 2

11/09/2007

Title:

INSTRUMENTATION METEOROLOGICAL MONITORING INSTRUMENTATION TEXT 3.3. 4 10 10/17 /2016

Title:

INSTRUMENTATION TRM POST-ACCIDENT MONITORING INSTRUMENTATION TEXT 3.3. 5 0

11/18/2002 Titl e : INSTRUMENTATION THIS PAGE I NTENTIONALLY LEFT BLANK

~"~~~~

TEXT 3. 3. 6 4

04/29/2014 Title : INSTRUMENTATION TRM ISOLATION ACTUATION INSTRUMENTATION TEXT 3.3.7 2

11/10/2015 Title : INSTRUMENTATION MAIN TURBINE OVERSPEED PROTECTION SYSTEM TEXT 3.3.8 1

10/22/2003 Tit le: INSTRUMENTATION TRM RPS INSTRUMENTATION TEXT 3. 3.9 3

04/17/2008 Title : OPRM INSTRUMENTATION CONFIGURATION TEXT 3.3.10 1

12/14/2004 Title : INSTRUMENTATION REACTOR RECIRCULATION PUMP MG SET STOPS TEXT 3.3.11 1

10/22/2003 Title : INSTRUMENTATION MVP ISOLATION INSTRUMENTATION TEXT 3.3.12 1

03/05/2015

_,?~..;

Title:

WATER MONITORING INSTRUMENTATION Page 2.

of 16 Report Date: 10/17/16

SSES MANUAL Manual Name:

TRMl Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.4.1 1

04/26/2006

Title:

REACTOR COOLANT SYSTEM REACTOR COOLANT SYSTEM CHEMISTRY TEXT 3.4.2 1

04/16/2009

Title:

REACTOR COOLANT SYSTEM STRUCTURAL INTEGRITY TEXT 3.4.3 1

11/09/2007

Title:

REACTOR COOLANT SYSTEM HIGH/LOW PRESSURE INTERFACE LEAKAGE MONITORS TEXT 3.4.4 2

04/17/2008

Title:

REACTOR COOLANT SYSTEM REACTOR RECIRCULATION FLOW AND ROD LINE LIMIT TEXT 3.4.5 1

04/26/2006

Title:

REACTOR COOLANT SYSTEM REACTOR VESSEL MATERIALS TEXT 3.4.6 2

04/25/2013

Title:

REACTOR RECIRCULATION SINGLE LOOP OPERATION SLO FLOW RATE RESTRICTION TEXT 3.5.1 1

02/04/2005

Title:

EMERGENCY CORE COOLING AND RCIC ADS MANUAL INHIBIT TEXT 3.5.2 1

11/09/2007

Title:

EMERGENCY CORE COOLING AND RCIC ECCS AND RCIC SYSTEM MONITORING INSTRUMENTATION TEXT 3.5.3 0

11/18/2002

Title:

EMERGENCY CORE COOLING AND RCIC LONG TERM NITROGEN SUPPLY TO ADS TEXT 3.6.1 0

11/18/2002

Title:

CONTAINMENT VENTING OR PURGING TEXT 3.6.2 2

04/29/2014

Title:

SUPPRESSION CHAMBER TO DRYWELL VACUUM BREAKER POSITION INDICATION TEXT 3.6.3 0

11/18/2002

Title:

CONTAINMENT SUPPRESSION POOL ALARM INSTRUMENTATION Page.l of.l.Q.

Report Date: 10/17/16

SSES MANUAL Manual Name:

TRMl Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.6.4 0

11/18/2002

Title:

CONTAINMENT PRIMARY CONTAINMENT CLOSED SYSTEM BOUNDARIES TEXT 3.7.1 0

11/18/2002

Title:

PLANT SYSTEMS EMERGENCY SERVICE WATER SYSTEM (ESW) SHUTDOWN TEXT 3.7.2 0

11/18/2002

Title:

PLANT SYSTEMS ULTIMATE HEAT SINK (illIS) AND GROUND WATER LEVEL TEXT 3.7.3.l 3

09/08/2016

Title:

PLANT SYSTEMS FIRE SUPPRESSION WATER SUPPLY SYSTEM TEXT 3.7.3.2 3

04/16/2009

Title:

PLANT SYSTEMS SPRAY AND SPRINKLER SYSTEMS TEXT 3.7.3.3 4

05/16/2016

Title:

PLANT SYSTEMS C02 SYSTEMS TEXT 3.7.3.4 2

04/16/2009

Title:

PLANT SYSTEMS HALON SYSTEMS TEXT 3.7.3.5 2

04/16/2009

Title:

PLANT SYSTEMS FIRE HOSE STATIONS TEXT 3.7.3.6 2

04/16/2009

Title:

PLANT SYSTEMS YARD FIRE HYDRANTS AND HYDRANT HOSE HOUSES TEXT 3.7.3.7 1

04/26/2006

Title:

PLANT SYSTEMS FIRE RATED ASSEMBLIES TEXT 3.7.3.8 10 09/27/2012

Title:

PLANT SYSTEMS FIRE DETECTION INSTRUMENTATION TEXT 3.7.4 1

04/26/2006

Title:

PLANT SYSTEMS SOLID RADWASTE SYSTEM Page 1-of li Report Date: 10/17/16

SSES MANUAL Manual Name:

TRMl Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.7.5.1 1

03/05/2015

Title:

PLANT SYSTEMS MAIN CONDENSER OFFGAS HYDROGEN MONITOR TEXT 3.7.5.2 0

11/18/2002

Title:

PLANT SYSTEMS MAIN CONDENSER OFFGAS EXPLOSIVE GAS MIXTURE TEXT 3.7.5.3 1

04/26/2006

Title:

PLANT SYSTEMS LIQUID HOLDUP TANKS TEXT 3.7.6 3

06/04/2012

Title:

PLANT SYSTEMS ESSW PUMPHOUSE VENTILATION TEXT 3.7.7 2

09/05/2008

Title:

PLANT SYSTEMS MAIN CONDENSER OFFGAS PRETREATMENT LOGARITHMIC RADIATION MONITORING TEXT 3.7.8 5

03/05/2015

Title:

PLANT SYSTEMS SNUBBERS TEXT 3.7.9 2

01/31/2014

Title:

PLANT SYSTEMS CONTROL STRUCTURE HVAC TEXT 3.7.10 1

12/14/2004

Title:

PLANT SYSTEMS SPENT FUEL STORAGE POOLS (SFSPS)

TEXT 3.7.11 0

04/16/2009

Title:

STRUCTURAL INTEGRITY TEXT 3.8.1 2

04/05/2010

Title:

ELECTRICAL POWER PRIMARY CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES TEXT 3.8.2.1 2

11/09/2007

Title:

ELECTRICAL POWER MOTOR OPERATED VALVES (MOV) THERMAL OVERLOAD PROTECTION -

CONTINUOUS TEXT 3.8:2.2

+

Title:

ELECTRICAL AUTOMATIC Page.5.

of li 2

12/14/2004 POWER MOTOR OPERATED VALVES (MOV) THERMAL OVERLOAD PROTECTION -

Report Date: 10/17/16

SSES MANUAL Manual Name:

TRMl Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.8.3 2

03/05/2015

Title:

ELECTRICAL POWER DIESEL GENERATOR (DG) MAINTENANCE ACTIVITIES TEXT 3.8.4 0

11/18/2002

Title:

ELECTRICAL POWER 24 VDC ELECTRICAL POWER SUBSYSTEM TEXT 3.8.5 1

11/14/2013

Title:

ELECTRICAL POWER DEGRADED VOLTAGE PROTECTION TEXT 3.8.6 1

12/08/2011

Title:

ELECTRICAL POWER EMERGENCY SWITCHGEAR ROOM COOLING TEXT 3.8.7 1

06/15/2009

Title:

BATTERY MAINTENANCE AND MONITORING PROGRAM TEXT 3.9.1 0

11/18/2002

Title:

REFUELING OPERATIONS DECAY TIME TEXT 3.9.2 0

11/18/2002

Title:

REFUELING OPERATIONS COMMUNICATIONS TEXT 3.9.3 0

11/18/2002

Title:

REFUELING OPERATIONS REFUELING PLATFORM TEXT 3.10.l 1

04/26/2006

Title:

MISCELLANEOUS SEAL SOURCE CONTAMINATION TEXT 3.10.2 2

08/08/2006 Titleg MISCELLANEOUS SHUTDOWN MARGIN TEST RPS INSTRUMENTATION TEXT 3.10.3 2

06/15/2010

Title:

MISCELLANEOUS INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI)

TEXT 3.10.4 2

04/17 /2008

Title:

MISCELLANEOUS LEADING EDGE FLOW METER (LEFM)

Page.Q of li Report Date: 10/17/16

SSES MANUAL Manual Name:

TRMl Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.11.1.1 1

04/26/2006

Title:

RADIOACTIVE EFFLUENTS LIQUID EFFLUENTS CONCENTRATION TEXT 3.11.1.2 1

04/26/2006

Title:

RADIOACTIVE EFFLUENTS LIQUID EFFLUENTS DOSE TEXT 3.11.1.3 1

04/26/2006

Title:

RADIOACTIVE EFFLUENTS LIQUID WASTE TREATMENT SYSTEM TEXT 3.11.1.4 2

10/09/2012

Title:

RADIOACTIVE EFFLUENTS LIQUID RADWASTE EFFLUENT MONITORING INSTRUMENTATION TEXT 3. 11. 1. 5 3

03/05/2015

Title:

RADIOACTIVE EFFLUENTS RADIOACTIVE LIQUID PROCESS MONITORING INSTRUMENTATION TEXT 3.11.2.1 3

04/26/2006

Title:

RADIOACTIVE EFFLUENTS DOSE RATE TEXT 3.11.2.2 1

04/26/2006

Title:

RADIOACTIVE EFFLUENTS DOSE -

NOBLE GASES TEXT 3.11.2.3 1

04/26/2006

Title:

RADIOACTIVE EFFLUENTS DOSE -

IODINE, TRITIUM, AND RADIONUCLIDES IN PARTICULATE FORM TEXT 3.11.2.4 0

11/18/2002

Title:

RADIOACTIVE EFFLUENTS GASEOUS RADWASTE TREATMENT SYSTEM TEXT 3.11.2.5 4

07/03/2013

Title:

RADIOACTIVE EFFLUENTS VENTILATION EXHAUST TREATMENT SYSTEM TEXT 3.11.2.6 7

10/17/2016

Title:

RADIOACTIVE EFFLUENTS RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION TEXT 3.11.3 1

04/26/2006

Title:

RADIOACTIVE EFFLUENTS TOTAL DOSE Page 1 of 1.Q.

Report Date: 10/17/16

SSES MANUAL Manual Name:

TID11 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 3.11.4.1 5

03/05/2015

Title:

RADIOACTIVE EFFLUENTS MONITORING PROGRAM TEXT 3.11.4.2 2

04/26/2006

Title:

RADIOACTIVE EFFLUENTS LAND USE CENSUS TEXT 3.11.4.3 1

04/26/2006

Title:

RADIOACTIVE EFFLUENTS INTERLABORATORY COMPARISON PROGRAM TEXT 3.12.1 0

11/19/2002

Title:

LOADS CONTROL PROGRAM CRANE TRAVEL-SPENT FUEL POOL STORAGE POOL TEXT 3.12.2 4

04/17/2008

Title:

LOADS CONTROL PROGRAM HEAVY LOADS REQUIREMENTS TEXT 3.12.3 0

11/19/2002

Title:

LOADS CONTROL PROGRAM LIGHT LOADS REQUIREMENT TEXT 4.1 0

08/31/1998

Title:

ADMINISTRATIVE CONTROLS ORGANIZATION TEXT 4.2 0

08/31/1998

Title:

ADMINISTRATIVE CONTROLS REPORTABLE EVENT ACTION TEXT 4.3 0

08/31/1998

Title:

ADMINISTRATIVE CONTROLS SAFETY LIMIT VIOLATION TEXT 4.4 1

12/18/2008

Title:

ADMINISTRATIVE CONTROLS PROCEDURES & PROGRAMS TEXT 4.5 0

08/31/1998

Title:

ADMINISTRATIVE CONTROLS REPORTING REQUIREMENTS TEXT 4.6 0

08/31/1998

Title:

ADMINISTRATIVE CONTROLS RADIATION PROTECTION PROGRAM Page Ji of.1Q Report Date: 10/17/16

SSES MANUAL Manual Name:

TRMl Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT 4. 7 0

08/31/1998

Title:

ADMINISTRATIVE CONTROLS TRAINING TEXT B3.0 5

03/05/2015

Title:

APPLICABILITY BASES TECHNICAL REQUIREMENT FOR OPERATION (TRO) APPLICABILITY TEXT B3.1.1 2

04/29/2014

Title:

REACTIVITY CONTROL SYSTEMS BASES ANTICIPATED TRANSIENT WITHOUT SCRAM ALTERNATE ROD INJECTION (ATWS-ARI) INSTRUMENTATION TEXT B3.l.2 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEMS BASES CONTROL ROD DRIVE (CRD) HOUSING SUPPORT TEXT B3.l.3 3

03/31/2006

Title:

REACTIVITY CONTROL SYSTEMS BASES CONTROL ROD BLOCK INSTRUMENTATION TEXT B3.l.4 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEMS BASES CONTROL ROD SCRAM ACCUMULATORS INSTRUMENTATION AND CHECK VALVE TEXT B3.2.1 0

11/19/2002

Title:

CORE OPERATING LIMITS BASES CORE OPERATING LIMITS REPORT (COLR)

TEXT B3.3.l 1

01/31/2014

Title:

INSTRUMENTATION BASES RADIATION MONITORING INSTRUMENTATION TEXT B3.3.2 2

03/31/2011

Title:

INSTRUMENTATION BASES SEISMIC MONITORING INSTRUMENTATION TEXT B3.3.3 3

12/18/2008

Title:

INSTRUMENTATION BASES METEOROLOGICAL MONITORING INSTRUMENTATION TEXT B3.3.4 6

09/08/2016

Title:

INSTRUMENTATION BASES TRM POST ACCIDENT MONITORING (PAM) INSTRUMENTATION TEXT B3.3.5 2

11/09/2007

Title:

INSTRUMENTATION BASES THIS PAGE INTENTIONALLY LEFT BLANK Page -2_

of li Report Date: 10/17/16

SSES MANUAL Manual Name:

TRMl Manual Title~ TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.3.6 5

01/31/2014

Title:

INSTRUMENTATION BASES TRM ISOLATION ACTUATION INSTRUMENTATION TEXT B3.3.7 2

11/10/2015

Title:

INSTRUMENTATION BASES MAIN TURBINE OVERSPEED PROTECTION SYSTEM TEXT B3.3.8 1

10/22/2003

Title:

INSTRUMENTATION BASES TRM REACTOR PROTECTION SYSTEM (RPS) INSTRUMENTATION TEXT B3.3.9 3

04/17/2008

Title:

OPRM INSTRUMENTATION TEXT B3.3.10 3

08/09/2010

Title:

INSTRUMENTATION BASES REACTOR RECIRCULATION PUMP MG SET STOPS TEXT B3.3.11 1

10/22/2003

Title:

INSTRUMENTATION BASES MVP ISOLATION INSTRUMENTATION TEXT B3.3.12 0

04/16/2009

Title:

WATER MONITORING INSTRUMENTATION TEXT B3.4.1 0

11/19/2002

Title:

REACTOR COOLANT SYSTEM BASES REACTOR COOLANT SYSTEM CHEMISTRY TEXT B3.4.2 1

04/16/2009

Title:

REACTOR COOLANT SYSTEM BASES STRUCTURAL INTEGRITY TEXT B3.4.3 1

11/09/2007

Title:

REACTOR COOLANT SYSTEM BASES HIGH/LOW PRESSURE INTERFACE LEAKAGE MONITOR TEXT B3.4.4 0

11/19/2002

Title:

REACTOR COOLANT SYSTEM BASES REACTOR RECIRCULATION FLOW AND ROD LINE LIMIT TEXT B3.4.5 0

11/19/2002

Title:

REACTOR COOLANT SYSTEM BASES REACTOR VESSEL MATERIALS Page 10 of 1..Q.

Report Date: 10/17/16

SSES MANUAL Manual Name:

TRMl Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.4.6 2

04/25/2013

Title:

REACTOR RECIRCULATION SINGLE LOOP OPERATION SLO FLOW RATE RESTRICTION TEXT B3.5.l 0

11/19/2002

Title:

ECCS AND RCIC BASES ADS MANUAL INHIBIT TEXT B3.5.2 1

11/09/2007

Title:

ECCS AND RCIC BASES ECCS AND RCIC SYSTEM MONITORING INSTRUMENTATION TEXT B3.5.3 1

11/09/2007

Title:

ECCS AND RCIC BASES LONG TERM NITROGEN SUPPLY TO ADS TEXT B3.6.l 0

11/19/2002

Title:

CONTAINMENT BASES VENTING OR PURGING TEXT B3.6.2 0

11/19/2002

Title:

CONTAINMENT BASES SUPPRESSION CHAMBER-TO-DRYWELL VACUUM BREAKER POSITION INDICATION TEXT B3.6.3 2

04/17/2008

Title:

CONTAINMENT BASES SUPPRESSION POOL ALARM INSTRUMENTATION TEXT B3.6.4 1

12/14/2004

Title:

CONTAINMENT BASES PRIMARY CONTAINMENT CLOSED SYSTEM BOUNDARIES TEXT B3.7.l 0

11/19/2002

Title:

PLANT SYSTEMS BASES EMERGENCY SERVICE WATER SYSTEM (SHUTDOWN)

TEXT B3.7.2 0

11/19/2002

Title:

PLANT SYSTEMS BASES ULTIMATE HEAT SINK (UHS) GROUND WATER LEVEL TEXT B3.7.3.1 3

06/15/2010

Title:

PLANT SYSTEMS BASES FIRE SUPPRESSION WATER SUPPLY SYSTEM TEXT B3.7.3.2 2

04/26/2006

Title:

PLANT SYSTEMS BASES SPRAY AND SPRINKLER SYSTEMS Page 11 of li Report Date: 10/17/16

SSES MANUAL Manual Name:

TRMl Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.7.3.3 0

11/19/2002

Title:

PLANT SYSTEMS BASES C02 SYSTEMS TEXT B3.7.3.4 3

04/29/2014

Title:

PLANT SYSTEMS-BASES HALON SYSTEMS TEXT B3.7.3.5 1

04/26/2006

Title:

PLANT SYSTEMS BASES FIRE HOSE STATIONS TEXT B3.7.3.6 1

04/26/2006

Title:

PLANT SYSTEMS BASES YARD FIRE HYDRANTS AND HYDRANT HOSE HOUSES TEXT B3.7.3.7 0

11/19/2002

Title:

PLANT SYSTEMS BASES FIRE RATED ASSEMBLIES TEXT B3.7.3.8 3

09/27/2012

Title:

PLANT SYSTEMS BASES FIRE DETECTION INSTRUMENTATION TEXT B3.7.4 0

11/19/2002

Title:

PLANT SYSTEMS BASES SOLID RADWASTE SYSTEM TEXT B3.7.5.1 0

11/19/2002

Title:

PLANT SYSTEMS BASES MAIN CONDENSER OFFGAS HYDROGEN MONITOR TEXT B3.7.5.2 0

11/19/2002

Title:

PLANT SYSTEMS BASES MAIN CONDENSER OFFGAS EXPLOSIVE GAS MIXTURE TEXT B3.7.5.3 0

11/19/2002

Title:

PLANT SYSTEMS BASES LIQUID HOLDUP TANKS TEXT B3.7.6 4

06/04/2013

Title:

PLANT SYSTEMS BASES ESSW PUMPHOUSE VENTILATION TEXT B3.7.7 2

01/31/2008

Title:

PLANT SYSTEMS BASES MAIN CONDENSER OFF GAS PRETREATMENT LOGARITHMIC. RADIATION MONITORING INSTRUMENTATION Page ll of 16 Report Date: 10/17/16

SSES MANUAL Manual Na:me :

TRMl Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.7.8 4

01/31/2014

Title:

PLANT SYSTEMS BASES SNUBBERS TEXT B3.7.9 2

12/08/2011

Title:

PLANT SYSTEMS BASES CONTROL STRUCTURE HVAC TEXT B3.7.10 1

12/14/2004

Title:

PLANT SYSTEMS BASES SPENT FUEL STORAGE POOLS TEXT B3.7.11 1

04/14/2010

Title:

STRUCTURAL INTEGRITY TEXT B3.8.l 2

03/10/2010

Title:

ELECTRICAL POWER BASES PRIMARY CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES TEXT B3.8.2.1 0

11/19/2002

Title:

ELE~TRICAL POWER BASES MOTOR OPERATED VALVES (MOV) THERMAL OVERLOAD PROTECTION -

CONTINUOUS TEXT B3.8.2.2 1

09/17/2004

Title:

ELECTRICAL POWER BASES MOTOR OPERATED VALVES (MOV) THERMAL OVERLOAD PROTECTION -

AUTOMATIC TEXT B3.8.3 0

11/19/2002

Title:

ELECTRICAL POWER BASES DIESEL GENERATOR (DG) MAINTENANCE ACTIVITIES TEXT B3.8.4 0

11/19/2002

Title:

ELECTRICAL POWER BASES 24 VDC ELECTRICAL POWER SUBSYSTEM TEXT B3.8.5 1

11/14/2013

Title:

ELECTRICAL POWER BASES DEGRADED VOLTAGE PROTECTION TEXT B3.8.6 2

12/08/2011

Title:

ELECTRICAL POWER BASES EMERGENCY SWITCHGEAR ROOM COOLING TEXT B3.8.7 2

06/04/2013

Title:

BATTERY MAINTENANCE AND MONITORING PROGRAM Page 13 of 16 Report Date: 10/17/16

SSES MANUAL Manual Name:

TRMl Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.9.1 0

11/19/2002 Title.: REFUELING OPERATIONS BASES DECAY TIME TEXT B3.9.2 0

11/19/2002

Title:

REFUELING OPERATIONS BASES COiv'.IMUNICATIONS TEXT B3.9.3 0

11/19/2002

Title:

REFUELING OPERATIONS BASES REFUELING PLATFORM TEXT B3.10.1 0

11/19/2002

Title:

MISCELLANEOUS BASES SEALED SOURCE CONTAMINATION TEXT B3.10.2 1

03/31/2006

Title:

MISCELLANEOUS BASES SHUTDOWN MARGIN TEST RPS INSTRUMENTATION TEXT B3.10.3 0

11/19/2002

Title:

MISCELLANEOUS BASES INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI)

TEXT B3.10.4 1

04/17/2008

Title:

MISCELLANEOUS BASES LEADING EDGE FLOW METER (LEFM)

TEXT B3.11.1.1 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES LIQUID EFFLUENTS CONCENTRATION TEXT B3.11.1.2 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES LIQUID EFFLUENTS DOSE TEXT B3.11.1.3 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES LIQUID WASTE TREATMENT SYSTEM TEXT B3.11.1.4 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES LIQUID RADWASTE EFFLUENT MONITORING INSTRUMENTATION TEXT B3.11.1.5 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES RADIOACTIVE LIQUID PROCESS MONITORING INSTRUMENTATION Page 14 of 16 Report Date: 10/17/16

SSES MANUAL Manual Name:

TRMl Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.11.2.1 1

12/14/2004

Title:

RADIOACTIVE EFFLUENTS BASES DOSE RATE TEXT B3.11.2.2 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES DOSE -

NOBLE GASES TEXT B3.11. 2. 3 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES DOSE -

IODINE, TRITIUM, AND RADIONUCLIDES IN PARTICULATES FORM TEXT B3.11.2.4 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES GASEOUS RADWASTE TREATMENT SYSTEM TEXT B3.11. 2. 5 5

07/03/2013

Title:

RADIOACTIVE EFFLUENTS BASES VENTILATION EXHAUST TREATMENT SYSTEM TEXT B3.11. 2. 6 2

09/08/2016

Title:

RADIOACTIVE EFFLUENTS BASES RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION TEXT B3.11. 3 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES TOTAL DOSE TEXT B3. 11. 4. 1 5

03/05/2015

Title:

RADIOACTIVE EFFLUENTS BASES MONITORING PROGRAM TEXT B3.11.4.2 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES LAND USE CENSUS TEXT B3.11.4.3 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES INTERLABORATORY COMPARISON PROGRAM TEXT B3.12.1 1

10/04/2007

Title:

LOADS CONTROL PROGRAM BASES CRANE TRAVEL-SPENT FUEL STORAGE POOL TEXT B3.12.2 1

12/03/2010

Title:

LOADS CONTROL PROGRAM BASES HEAVY LOADS REQUIREMENTS Page 15 of li Report Date: 10/17/16

SSES MANUAL Manual Name:

TRMl

  • ~;-~, Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 1 TEXT B3.12.3 0

11/19/2002

Title:

LOADS CONTROL PROGRAM BASES LIGHT LOADS REQUIREMENTS Page 16 of

.lQ_

Report Date: 10/17/16

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 88 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date TOC TABLE OF CONTENTS 04/23/2015 1.0 USE AND APPLICATION Page TRM I 1.0-1 10/04/2002 Page TRM I 1.0-2 01/21/2014 Page TRM I 1.0-3 10/04/2002 2.0 PLANT PROGRAMS Page TRM I 2.0-1 04/23/2015 Pages TRM I 2.0-2 and TRM I 2.0-3 01/28/2005 Page TRM I 2.0-4 06/25/2002 Page TRM I 2.0-5 01/21/2014 Page TRM I 2.0-6 03/27/2008 Page TRM I 2.0-7 05/15/2008 Pages TRM I 2.0-8 and TRM I 2.0-9 01/07/2011 Page TRM I 2.0-1 0 02/02/2010 Page TRM I 2.0-11 11/15/2004 Page TRM I 2.0-12 03/27/2008 Pages TRM I 2.0-13 and TRM I 2.0-14 11/15/2004 Page TRM I 2.0-15 11/15/2005 3.0 APPLICABILITY Pages TRM I 3.0-1 and TRM I 3.0-2 02/19/2015 Page TRM I 3.0-3 03/15/2002 Page TRM I 3.0-4 02/19/2015 3.1 REACTIVITY CONTROL SYSTEMS Page TRM I 3.1 -1 10/31/2007 Pages TRM I 3.1-2 and TRM I 3.1-3 08/31/1998 Pages 3.1-4 and 3.1-5 08/31/1998 Page TRM I 3.1-6 03/22/2006 Page TRM I 3.1-7 04/07/2009 Page TRM I 3.1-8 03/27/2008 Pages TRM I 3.1-9 and TRM I 3.1 -9a 02/18/1999 Page TRM I 3.1-10 02/18/1999 3.2 CORE OPERATING LIMITS REPORT Page TRM I 3.2-1 07/07/1999 Pages TRM I 3.2-2 through TRM I 3.2-63 03/24/2016 3.3 INSTRUMENTATION Pages TRM I 3.3-1 through TRM I 3.3-3 07/16/1999 Page TRM I 3.3-4 and TRM I 3.3-5 10/31/2007 Page TRM I 3.3-6 03/10/2011 SUSQUEHANNA - UNIT 1 TRM I LOES-1 EFFECTIVE DATE 10/06/2016

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 88 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date Page TRM I 3.3-7 10/31/2007 Page TRM / 3.3-8 08/31/1998 Page TRM / 3.3-9 10/07/2015 Page TRM / 3.3-9a 06/30/2010 Page TRM / 3.3-10 10/31/2007 Page TRM / 3.3-11 10/07/2015 Page TRM / 3.3-11a 10/06/2016 Page TRM / 3.3-12 03/30/2001 Page TRM / 3.3-13 01/07/2011 Page TRM / 3.3-14 12/14/1998 Page TRM / 3.3-15 04/11/2014 Page TRM I 3.3-16 01/07/2011 Page TRM I 3.3-17 11/04/2015 Page TRM I 3.3-17a 11/04/2015 Page TRM I 3.3-18 10/31/2007 Pages TRM I 3.3-19 through TRM / 3.3-21 10/22/2003 Page TRM / 3.3-22 03/27/2008 Page TRM / 3.3-22a 11/15/2004 Pages TRM I 3.3-22b through TRM I 3.3-22d 03/22/2006 Page TRM / 3.3-23 12/03/2004 Pages TRM I 3.3-24 and TRM I 3.3-25 05/16/2003 Page TRM I 3.3-26 10/22/2003 Page TRM / 3.3-27 02/19/2015 Page TRM/ 3.3-28 04/07/2009 3.4 REACTOR COOLANT SYSTEM Page TRM I 3.4-1 03/31/2006 Pages TRM I 3.4-2 through TRM I 3.4-5 10/23/1998 Pages TRM I 3.4-6 through TRM I 3.4-8 04/01/2009 Page TRM I 3.4-9 08/31/1998 Page TRM / 3.4-10 10/31/2007 Page TRM I 3.4-11 08/31/1998 Page TRM / 3.4-12 03/27/2008 Page TRM / 3.4-13 03/31/2006 Pages TRM / 3.4-14 and TRM / 3.4-15 04/25/2013 3.5 EMERGENCY CORE COOLING AND RCIC Page TRM / 3.5-1 01/28/2005 Pages TRM / 3.5-2 and TRM I 3.5-3 08/31/1998 Pages TRM I 3.5-4 and TRM / 3.5-5 10/31/2007 Pages 3.5-6 and 3.5-7 08/31/1998 SUSQUEHANNA - UNIT 1 TRM I LOES-2 EFFECTIVE DATE 10/06/2016

I e I

I I

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 88 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title 3.6 3.7 CONTAINMENT Page 3.6-1 Pages TRM I 3.6-2 and TRM I 3.6-2a Page 3.6-3 Page TRM I 3.6-4 Page 3.6-5 Pages TRM I 3.6-6 through TRM I 3.6-8 PLANT SYSTEMS Pages 3.7~1 through 3.7-3 Page TRM I 3. 7-4 Pages TRM I 3.7-5 through TRM I 3.7-7 Page TRM I 3. 7-8 Pages TRM I 3.7-9 and TRM I 3.7-10 Page TRM I 3.7-11 Page TRM I 3.7-12 Page TRM I 3.7.13 Page TRM I 3.7-14 Pages TRM I 3.7-15 and TRM I 3.7-16 Page TRM I 3.7-17 Page TRM / 3.7-18 Page TRM / 3.7-19 Pages TRM / 3.7-20 through TRM / 3.7-22 Page TRM I 3. 7-23.

Page TRM / 3.7-24 Page TRM I 3. 7-25 Page TRM / 3. 7-26 Page TRM / 3.7-27 Pages TRM / 3.7-28 through TRM / 3.7-34a Page TRM I 3. 7-35 Pages TRM / 3.7-36 and TRM / 3.7-37 Page TRM / 3.7-38 Page TRM I 3. 7-39 Page TRM / 3.7-40 Page TRM / 3.7-41 Pages TRM / 3.7-41a through TRM / 3.7-41c Page TRM / 3.7-42 Page TRM I 3. 7-43 Page TRM / 3.7-44 Pages TRM / 3.7-45 and TRM / 3.7-46 Page TRM / 3. 7-47 SUSQUEHANNA - UNIT 1 TRM I LOES-3 Effective Date 08/31/1998 04/16/2014 08/31/1998 01/07/2002 08/31/1998 12/31/2002 08/31/1998 03/31/2006 08/18/2016 08/02/1999 04/07/2009 12/29/1999 08/02/1999 05/09/2016 08/09/2005 08/02/1999 04/07/2009 08/02/1999 04/07/2009 08/02/1999 04/07/2009 03/31/2006 08/02/1999 09/25/2012 11/24/2011 09/25/2012 03/31/2006 02/01/1999 02/19/2015 08/31/1998 03/31/2006 05/24/2012 05/24/2012 09/04/2008 08/31/1998 02/19/2015 10/05/2006 06/07/2007 EFFECTIVE DATE 10/06/2016

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 88 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date Page TRM I 3.7-48 10/05/2006 Page TRM I 3. 7-49 06/07/2007 Page TRM I 3. 7-50 01/21/2014 Page TRM I 3.7-51 08/16/2006 Page TRM I 3.7-52 12/03/2004 Page TRM I 3. 7-53 04/15/2003 Page TRM I 3. 7-54 07/29/1999 Pages TRM I 3.7-55 through TRM I 3.7-57 0:4/01/2009 3.8 ELECTRICAL POWER Page TRM I 3.8-1 0410212002 Page TRM I 3.8-2 01/28/2005 Pages TRM I 3.8-3 and TRM /3.8-4 03/25/2010 Pages TRM I 3.8-5 and TRM I 3.8-6 0410212002 Page TRM I 3.8-7 10/31/2007 Pages TRM I 3.8-8 through TRM I 3.8-10 12/03/2004 Page TRM I 3.8-11 09/03/2004 Page TRM I 3.8-12 12/03/2004 Page TRM I 3.8-13 02/19/2015 Page TRM I 3.8-14 08/31/1998 Pages TRM I 3.8-15 through TRM I 3.8-17 0410212002 Page 3.8-18 08/31/1998 Page TRM I 3.8-*19 0410212002 Page 3.8-20 08/31/1998 Pages TRM I 3.8-21 and TRM I 3.8-22 06/06/1999 Page TRM I 3.8-23 11/07/2013 Pages TRM I 3.8-24 and TRM I 3.8-25 11/30/2011 Page TRM I 3. 8-26 05/28/2009 Page TRM I 3.8-27 11/29/2006 Pages TRM I 3.8-28 and TRM I 3.8-29 05/28/2009 3.9 REFUELING OPERATIONS Pages 3.9-1 through 3.9-3 08/31/1998 3.10 MISCELLANEOUS Page TRM I 3.10-1 03/31/2006 Pages TRM I 3.10-2 and TRM I 3.10-3 08/31/1998 Page TRM I 3.10-4 08/01/2006 Pages TRM I 3.10-5 and TRM I 3.10-6 03/22/2006 Page TRM I 3.10-7 06/10/2010 Page TRM I 3.10-8 03/27/2008 SUSQUEHANNA - UNIT 1 TRM I LOES-4 EFFECTIVE DATE 10/06/2016

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 88 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date 3.11 RADIOACTIVE EFFLUENTS Page TRM / 3.11-1 03/31/2006 Pages TRM / 3.11-2 and TRM / 3.11-3 08/31/1998 Page TRM / 3.11-4 03/31/2006 Page TRM / 3.11-5 08/31/1998 Page TRM / 3.11-6 03/31/2006 Pages TRM / 3.11-7 and TRM / 3.11-8 08/31/1998 Pages TRM / 3.11-9 and TRM / 3.11-10 10/09/2012 Pages TRM / 3.11-1 'I and TRM / 3.11-12 08/31/1998 Page TRM / 3.11-13 02/19/2015 Page TRM / 3.~ 1-14 12/03/2004 "Pages 3.11-15 and 3.11-16 09/01/1998 Page TRM / 3.11-17 03/31/2006 Page 3.11-18 08/3V1998 Page TRM / 3.11-19 08/15/2005 Pages TRM / 3.11-20 and TRM / 3.11-21 03/31/2006 Page TRM / 3.11-22 0410212002 Page TRM / 3.11-23 11/14/2006 Page TRM / 3.11-24 06/18/2013 Page TRM / 3.11-25 04/12/2007 Page TRM I 3.11-26 01/21/2004 Page TRM / 3.11-27 08/11/2016 Page TRM / 3.11-28 10/06/2016 Page TRM / 3.11-29 12/03/2004 Page TRM I 3.11.30 01/21/2004 Page TRM / 3.11.31 08/11/2016 Page TRM I 3.11.32 10/06/2016

,J Page TRM / 3.11-33 03/31/2006 Page TRM I 3.11-34 08/31/1998 Page TRM I 3.11-35 03/31/2006 Pages TRM I 3.11-36 through TRM I 3.11-39 11/30/2005 Page TRM / 3.11-40 02/19/2015 Pages TRM I 3.11-41 through TRM I 3.11-43 08/31/1998 Page TRM / 3.11-44 08/01/2006 Page TRM / 3.11-45 03/31/2006 Page 3.11-46 08/31/1998 Page TRM/ 3.11-47 03/31/2006 3.12 LOADS CONTROL PROGRAM Pages TRM / 3.12-1 through TRM I 3.12-3 02/05/1999 Page TRM / 3.12-4 03/14/2008

  • Page TRM / 3.12-5 02/05/1999 4.0 ADMINISTRATIVE CONTROLS Pages 4.0-1 through 4.0-3 08/31/1998 Page TRM I 4.0-4 12/11/2008 Pages 4.0-5 through 4.0-8 08/31/1998

--~-:.:::~-:.

SUSQUEHANNA - UNIT 1 TRM I LOES-5 EFFECTIVE DATE 10/06/2016

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 88 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title B 3.0 B 3.1 B 3.2 B 3.3 APPLICABILITY BASES Pages TRM I B 3.0-1 through TRM I B 3.0-3 Page TRM I B 3.0-4 Page TRM I B 3.0-4a and TRM I B 3.0-4b Page TRM I B 3.0-5 Page TRM I B 3.0-6 Page TRM I B 3.0-7 Pages TRM I B 3.0-8 and TRM I B 3.0-9 Pages TRM I B 3.0-10 and TRM I B 3.0-11 Page TRM I B 3.0-12 Pages TRM I B 3.0-13 through TRM I B 3.0-15 REACTIVITY CONTROL SYSTEMS BASES Page TRM I B 3.1-1 Page TRM I B 3.1-2 Page TRM I B 3.1-3 Page B 3.1-4 Page TRM I B 3.1-5 Pages TRM I B 3.1-6 and TRM I B 3.1-7 Page TRM I B 3.1-8 CORE OPERATING LIMITS BASES Page B 3.2-1 INSTRUMENTATION BASES Page TRM I B 3.3-1 Page TRM I B 3.3-2 Page TRM I B 3.3-2a Page TRM I B 3.3-3 Page TRM I B 3.3-3a Page TRM I B 3.3-4 Pages TRM I B 3.3-5 and TRM I B 3.3-5a Page TRM I B 3.3-6 Page TRM I B 3.3-7 Page TRM I B. 3.3-8 Page TRM I B 3.3-9 Pages TRM I B 3.3-10 through TRM I B 3.3-12 Page TRM I B 3.3-13 Page TRM I B 3.3-14 Page TRM I B 3.3-14a Page TRM I B 3.3-14b Page TRM I B 3.3-14c Pages TRM I B 3.3-15 and TRM I B 3.3-16 Page TRM I B 3.3-17 Pages TRM I B 3.3-17a through TRM I B 3.3-17c Page TRM I B 3.3-17d SUSQUEHANNA - UNIT 1 TRM I LOES-6 Effective Date 08/31/1998 02/19/2015 02/19/2015 02/19/2015 08/31/1998 04/12/2007 08/31/1998 03/15/2002 11/30/2005 02/19/2015 07/13/1999 04/16/2014 10/31/2007 08/31/1998 11/15/2005 03/22/2006 02/18/1999 08/31/1998 01/21/2014 03/10/2011 10/31/2007 12/11/2008 10/31/2007 06/30/2010 08/11/2016 06/30/2010 10/07/2015

.06/30/2010 10/31/2007 01/07/2011 01/21/2014 06/25/2002 11/04/2015 11/04/2015 11/04/2015 10/22/2003 03/22/2006 03/22/2006 03/27/2008 EFFECTIVE DATE 10/06/2016

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 88 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date Pages TRM I B 3.3-17e and TRM I B 3.3-17f 03/22/2006 Pages TRM I B 3.3-18 and TRM I B 3.3-19 08/03/2010 Page TRM I B 3.3-20 10/22/2003 Page TRM I B 3.3-21 05/16/2003 Pages TRM I B 3.3-22 and TRM I B 3.3-23 04/07/2009 B 3.4 REACTOR COOLANT SYSTEM BASES Page B 3.4-1 08/31/1998 Pages TRM I B 3.4-2 and TRM I B 3.4-3 04/01/2009 Pages TRM I B 3.4-4 and TRM I B 3.4-4a 10/31/2007 Page TRM I B 3.4-5 10/15/1999 Page B 3.4-6 08/31/1998 Pages TRM I B 3.4-7 and TRM I B 3.4-8 04/25/2013 B 3.5 ECCS AND RCIC BASES Pages B 3.5-1 and B 3.5-2 08/31/1998 Pages TRM I B 3.5-3 through TRM I B 3.5-5 10/31/2007 B 3.6 CONTAINMENT BASES Page TRM I B 3.6-1 07/26/2001 Page TRM I B 3.6-2 02/01/1999 Page B 3.6-3 08/31/1998 Page TRM I B 3.6-4 03/27/2008 Page TRM *1 B 3.6-5 04/04/2007 Page TRM I B 3.6-6 12/03/2004 Pages TRM I B.3.6-7 through TRM I B 3.6-11 12/31/2002 B 3.7 PLANT SYSTEMS BASES Pages B 3.7-1 and B 3.7-2 08/31/1998 Page TRM I B 3.7-3 06/10/2010 Page TRM I B 3.7-3a 12/27/2007 Page TRM I B 3.7-4 03/31/2006 Page TRM I B 3.7-5 08/02/1999 Page TRM I B 3.7-6 03/31/2006 Pages TRM I B 3.7-7 and TRM I B 3.7-7a 08/02/1999 Page TRM I B 3.7-8 05/29/2013 Page TRM I B 3.7-9 04/11/2014 Page TRM I B 3.7-10 08/02/1999 Page TRM I B 3.7-10a 03/31/2006 Page TRM I B 3.. 7-11 08/02/1999 Page TRM I B 3.7-11a 03/31/2006 Pages TRM I B 3.7-12 and TRM I B 3.7-13 08/02/1999 Pages TRM I B 3.7-14 and TRM I B 3.7-14a 09/25/2012 SUSQUEHANNA - UNIT 1 TRM I LOES-7 EFFECTIVE DATE 10/06/2016

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 88 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date Page TRM I B 3.7-14b 11/24/2011 Pages TRM I B 3.7-15 and TRM I B 3.7-16 02/01/1999 Pages B 3.7-17 through B 3.7-20 08/31/1998 Page TRM I B 3.7-21 05/29/2013 P~ges TRM I B 3.7-21a through TRM I B 3.7-21d 05/24/2012 Pages TRM I B 3.7-21e through TRM I B 3.7-21g 05/29/2013 Page TRM I B 3.7-22 and.TRM I B 3.7-23 01/30/2008 Page TRM I B 3.7-24 10/05/2006 Page TRM I B 3.7-25 01/21/2014 Pages TRM I B 3.7-26 through TRM I B 3.7-28 10/05/2006 Pages TRM I B 3.7-29 and TRM I B 3.7-30 06/07/2007 Page TRM I B 3.7-30a 10/05/2006 Page TRM I B 3.7-30b 01/21/2014 Page TRM I B 3.7-31 11/30/2011 Page TRM I B 3.7-32 03/09/2001 Page TRM I B 3.7-33 04/15/2003 Page TRM I B 3.7-34 12/03/2004 Page TRM I B 3.7-35 0710512000 Pages TRM I B 3. 7-36 through TRM I B 3. 7-39 04/01/2009 Page TRM I B 3.7-40 04/08/2010 B 3.8 ELECTRICAL POWER BASES Page TRM I B 3.8-1 04/02/2002 Page TRM I B 3.8-2 01/28/2005 Page TRM I B 3.8-2a 03/01/2010 Page TRM I B 3.8-3 0410212002 Page TRM I B 3.8-3a 04/02/2002 Page TRM I B 3.8-4 09/03/2004 Page TRM I B 3.8-4a 0410212002 Page B 3.8-5 08/31/1998 Pages TRM I B 3.8-6 through TRM I B 3.8-15 0410212002 Page TRM I B 3.8-16 11/07/2013 Page TRM I B 3.8-17 11/30/2011 Pages TRM I B 3.8-17a and TRM I B 3.8-17b 11/30/2011 Pages TRM I B 3.8-18 through TRM I B 3.8-20 05/29/2013 Pages TRM* / B 3.8-21 and TRM I B 3.8-22 05/28/2009

. Page TRM I B 3.8-23 05/29/2013 Page TRM I B 3.8-24 05/28/2009 B.3.9 REFUELING OPERATIONS BASES Pages B 3.9-1 through B 3.9-7 08/31/1998 SUSQUEHANNA - UNIT 1 TRM I LOES-8 EFFECTIVE DATE 10/06/2016

SUSQUEHANNA STEAM ELECTRIC STATION Rev. 88 LIST OF EFFECTIVE SECTIONS (TECHNICAL REQUIREMENTS MANUAL)

Section Title Effective Date B 3.10 MISCELLANEOUS BASES Page B 3.10-1 08/31/1998 Pages TRM I B 3.10-2 and TRM I B 3.10-3 03/22/2006 Pages TRM I B 3.10-4 and TRM I B 3.10-5 08/23/1999 Page TRM I B 3.10-6 03/27/2008 B 3.11 RADIOACTIVE EFFLUENTS BAS.ES Pages B 3.11-1throughB3.11-9 08/30/1998 Page TRM I B 3.11-10 02/01/1999 Pages TRM/B 3.11-11 and TRM/B 3.11-11a 0410712000 Pages TRM/B 3.11-12 and TRM/B 3.11-13 02/01/1999 Page TRM I B 3.11-14 12/03/2004 Page TRM I B 3.11-15 02/01/1999 PagesB 3.11-16 through B 3.11-19 08/30/1998 Page TRM I B 3.11-20 04/02/2002 Page TRM I B 3.11-20a 04/02/2002 Page TRM I B 3.11-21 05/13/2005 Pages TRM I B 3.11-22 and TRM I B 3.11-23 11/14/2006 Pages TRM I B 3.11-23a and TRM I B 3.11-23b 06/18/2013 Pages TRM I B 3.11-24 and TRM I B 3.11-24a 08/11/2016 Page TRM I B 3.11-25 01/21/2004 Pages B 3.11-26 and B 3.11-27 08/30/1998 Page TRM I B 3.11-28 11/30/2005 Page TRM I B 3.11-29 02/19/2015 Pages TRM I B 3.11-30 and TRM I B 3.11-31 05/29/2013 Page TRM I B 3.11-32 08/30/1998 Page TRM I B 3.11-33 06/30/2010 Pages B 3.11-34 and B 3.11-35 08/30/1998 Page TRM I B 3.11-36 02/12/1999 B.3.12 LOADS CONTROL PROGRAM BASES Page TRM I B 3.12-1 09/19/2007 Page TRM I B 3.12-2 11/29/2010 Page TRM I B 3.1.2-3 02/05/1999 SUSQUEHANNA - UNIT 1 TRM I LOES-9 EFFECTIVE DATE 10/06/2016

Rev. 10 TRM Post Accident Monitoring Instrumentation.

3.3.4 3.3 Instrumentation 3.3.4 TRM Post-Accident Monitoring Instrumentation TRO 3.3.4 The TRM post-accident monitoring instrumentation channels shown in Table 3.3.4-1 shall be OPERABLE.

APPLICABILITY:

According to Table 3.3.4-1 ACTIONS


N 0 TES-------------------------------------------------------------

1. Separate condition entry is allowed for each Function.
2. The provisions of TRO 3.0.6 are not applicable.

CONDITION REQUIRED ACTION COMPLETION TIME A.

One or more required A.1 Enter the Condition referenced Immediately channel inoperable.

in Table 3.3.4-1 for the channel.

B.

As required by Required B.1 Initiate the preplanned 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> Action A.1 and referenced alternate method of monitoring in Table 3.3.4-1.

the appropriate parameter(s).

AND B.2 Restore the required channel 7 days I 30 days (c) to OPERABLE status.

C.

As required by Required C.1 Restore the required 30 days

  • Action A.1 and referenced channel(s) to OPERABLE in Table 3.3.4-1
  • status.

D. As required by Required D.1 Verify a minimum 14 of the Immediately Action A.1 and referenced in associated acoustic monitor Table 3.3.4-1 channels and 5 of the ADS AND SRV acoustic monitor channels are operable.

Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter (cJ COMPLETION TIME for REQUIRED ACTION B.2 is extended from 7 to 30 days during construction activities associated with the replacement of SPING equipment with VERMS equipment.

SUSQUEHANNA - UNIT 1 TRM I 3.3-9 EFFECTIVE DATE 10/07/2015

Rev. 10 ACTIONS (continued)

CONDITION SUSQUEHANNA - UNIT 1 OR D.2 OR D.3 AND D.4 TRM Post Accident Monitoring Instrumentation 3.3.4 REQUIRED ACTION Verify SRV tailpipe temperature indication and alarm are available for the tailpipe associated with the inoperable acoustic monitor.

Verify that the following alternate monitoring methods in TS Table 3.3.3.1-1 are OPERABLE:

a Function 1 Function 2

~

Function 3 a

Function 10 Restore the required channel(s) to OPERABLE status.

COMPLETION TIME Immediately AND Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter Immediately AND Once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter 30 days At next outage with containment entry, not to exceed the next refueling outage for in-accessible containment components.

TRM I 3.3-9a EFFECTIVE DATE 06/30/2010

Rev. 10 TRM Post Accident Monitoring Instrumentation 3.3.4 TECHNICAL REQUIREMENT SURVEILLANCE


NOTES ---------------------------------------------------------

1.

Refer to Table 3.3.4-1 to determine which TRSs apply for each Post Accident Monitoring Function.

2.

When a channel is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed for up to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> provided an alternate means of monitoring the parameter or an associated function is available.

SURVEILLANCE FREQUENCY TRS 3.3.4.1 Perform CHANNEL CHECK 31 days TRS 3.3.4.2 Perform CHANNEL FUNCTIONAL TEST 92 days TRS 3.3.4.3 Perform a CHANNEL CALIBRATION. The Trip 24 months Setpoint shall be less than or equal to 0.25 of the full open noise level.

TRS 3.3.4.4 Perform CHANNEL CALIBRATION 24 months TRS 3.3.4.5.

Perform CHANNEL CALIBRATION of the 92 days Primary Containment H2 and 0 2 Analyzers.

SUSQUEHANNA - UNIT 1 TRM I 3.3-10 EFFECTIVE DATE 10/31/2007

1.
2.
3.
4.
5.

Rev. 10 TRM Post Accident Monitoring Instrumentation 3.3.4 TABLE 3.3.4-1 TRM POST-ACCIDENT MONITORING INSTRUMENTATION APPLICABLE CONDITIONS MODES OR OTHER REFERENCED SPECIFIED REQUIRED FROM REQUIRED REQUIRED FUNCTION CONDITIONS CHANNELS ACTION A.1 SURVEILLANCE Suppression Chamber Air 1,2 2

c TRS 3.3.4.1 Temperature TRS 3.3.4.4 Main Steam Safety/Relief Valve 1,2 1/valve D

TRS 3.3.4.1 Position Indicator (Acoustic TRS 3.3.4.2 Monitor)

TRS 3.3.4.3 Reactor Building Vent Noble Gas Monitor

a. Mid RangeCbl 1,2, (a)

B TRS 3.3.4.1 TRS 3.3.4.4

b. High RangeCbl 1,2, (a)

B TRS 3.3.4.1 TRS 3.3.4.4 Standby Gas Treatment System Vent Noble Gas Monitor

a. Mid RangeCbl 1,2, (a)

B TRS 3.3.4.1 TRS 3.3.4.4

b. High Range(bl 1,2, (a)

B TRS 3.3.4.1 TRS 3.3.4.4 Turbine Building Vent Noble Gas Monitor

a. Mid Range(b) 1,2 1

B TRS 3.3.4.1 TRS 3.3.4.4

b. High Range(b) 1,2 1

B TRS 3.3.4.1 TRS 3.3.4.4 (continued)

SUSQUEHANNA - UNIT 1 TRM I 3.3-11 EFFECTIVE DATE 10/07/2015

Rev. 10 TRM Post Accident Monitoring Instrumentation 3.3.4 TABLE 3.3.4-1 (continued)

TRM POST-ACCIDENT MONITORING INSTRUMENTATION APPLICABLE CONDITIONS MODES OR OTHER REFERENCED SPECIFIED REQUIRED FROM REQUIRED REQUIRED FUNCTION CONDITIONS CHANNELS ACTION A.1 SURVEILLANCE

6.

Standby Gas Treatment System Vent Stack Sampling System Flow

a.

Effluent System flow rate monitor(b) 1,2, (a) c TRS 3.3.4.1 TRS 3.3.4.4

b.

Sample flow rate monitor(b) 1,2, (a) c TRS 3.3.4.1 (Mid/High Range & Bypass)

TRS 3.3.4.4

7.

Turbine Building Vent Stack Sampling System Flow

a.

Effluent System flow rate monitor(b) 1,2 c

TRS 3.3.4.1 TRS 3.3.4.4

b.

Sample flow rate monitor(b)

TRS 3.3.4.1 (Mid/High Range & Bypass) 1,2 1

c TRS 3.3.4.4

8.

Containment H2 and 0 2 Analyzer(bJ 1,2 2

c TRS 3.3.4.1 TRS 3.3.4.5 (a)

When moving irradiated fuel in the secondary containment.

(b)

TRO 3.0.4.c is applicable.

SUSQUEHANNA - UNIT 1 TRM / 3.3-11a EFFECTIVE DATE 10/06/2016

Rev. 7 Radioactive Gaseous Effluent Monitoring Instrumentation 3.11.2.6 3.11 Radioactive Effluents 3.11.2 Gaseous Effluents 3.11.2.6 Radioactive Gaseous Effluent Monitoring Instrumentation TRO 3.11.2.6 The radioactive gaseous effluent monitoring instrumentation channels shown in Table 3.11.2.6-1 shall be OPERABLE with their setpoints established in accordance with the ODCM to ensure that the limits of Requirement 3.11.2.1 are not exceeded.

APPLICABILITY:

According to Table 3.11.2.6-1 ACTIONS


NOTE --------------------------------------------------------

1. Separate condition entry is allowed for each channel.
2. The provisions of TRO 3.0.6 are not applicable.

CONDITION REQUIRED ACTION COMPLETION TIME A.

Radioactive gaseous A.1 Suspend the release of Immediately effluent monitoring radioactive gaseous effluents instrumentation channel

  • monitored by the affected alarm/trip setpoint less channel conservative than required to ensure that the limits of OR Requirement 3.11.2.1 are not exceeded A.2 Declare the channel Immediately inoperable (continued)'

SUSQUEHANNA - UNIT 1 TRM I 3.11-25 EFFECTIVE DATE 04/12/2007

Rev. 7 ACTIONS (continued)

CONDITION B.

Reactor Building Ventilation System Noble Gas Activity Monitor low range channel inoperable C.

Deleted D.

Reactor Building Ventilation Monitoring System Effluent System Flow Rate Monitor or Sampler Flow Rate Monitor inoperable SUSQUEHANNA - UNIT 1 Radioactive Gaseous Effluent Monitoring Instrumentation 3.11.2.6 REQUIRED ACTION COMPLETION TIME B.1 Take grab samples Once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> while release is in progress.

AND B.2 Analyze grab samples for Within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> isotopic activity to the required of grab sample LLDs for principal noble gas gamma emitters (Table 3.11.2.1-1)

AND B.3 Restore monitoring 30 days instrumentation D.1 Estimate flow rate Once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> while release is in progress AND D.2 Restore monitoring 30 days instrumentation (continued)

TRM I 3.11-26 EFFECTIVE DATE 01/21/2004

Rev. 7 ACTIONS (continued)

CONDITION E.

Turbine Building Ventilation System Noble Gas Activity Monitor low range channel inoperable F.

Deleted G.

Turbine Building Ventilation Monitoring System:

Effluent Flow Rate Monitor or Sample (Bypass or Low Range) Flow Rate Monitor inoperable SUSQUEHANNA - UNIT 1 Radioactive Gaseous Effluent Monitoring Instrumentation 3.11.2.6 REQUIRED ACTION COMPLETION TIME E.1 Verify mechanical vacuum Immediately pump is not in operation AND E.2 Take grab samples Once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> while release is in progress AND E.3 Analyze grab samples for Within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after isotopic activity to the sample required LLDs for the principal noble gas gamma emitters (Table 3.11.2.1-1)_

AND E.4 Restore monitoring instrumentation 30 days G. 1 Estimate flow rate Once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> while release is in progress.

AND G.2 Restore monitoring 30 days instrumentation (continued)

TRM I 3.11-27 EFFECTIVE DATE 08/11/2016

r Rev. 7 ACTIONS (continued)

CONDITION H.

Standby Gas Treatment System Noble Gas Activity Monitor low range channel inoperable I.

Deleted J.

SGTS Ventilation Monitoring System:.

Effluent flow rate monitor or sample (Bypass or Low Range) flow rate monitor inoperable SUSQUEHANNA - UNIT 1 Radioactive Gaseous Effluent Monitoring Instrumentation 3.11.2.6 REQUIRED ACTION COMPLETION TIME H.1 Take grab samples Once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> during operation of SGTS AND H.2 Analyze grab samples for Within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> isotopic activity to the required of grab sample LLDs for principal noble gas being taken gamma emitters (Table 3.11.2.1-1)

AND H.3 Restore monitoring 30 days instrumentation J.1 Estimate flow rate Once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> during operation of SGTS AND J.2 Restore monitoring 30 days instrumentation (continued)

TRM I 3.11-28 EFFECTIVE DATE 10/06/2016

Rev. 7 Radioactive Gaseous Effluent Monitoring Instrumentation 3.11.2.6 ACTIONS (continued)

CONDITION I<.

Required Actions and Completion Times not met for Conditions B through J REQUIRED ACTION K.1 Explain why this inoperability was not corrected in a timely manner TECHNICAL REQUIREMENT SURVEILLANCE COMPLETION TIME In the next Radioactive Effluent Release Report per TS Section 5.6


NOTE --------------------------------------------------------

Refer to Table 3.11.2.6-1 to determine which TRSs apply for each Monitoring Function.

SURVEILLANCE FREQUENCY TRS 3.11.2.6.1 Perform CHANNEL CHECK 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> TRS 3.11.2.6.2 Deleted TRS 3.11.2.6.3 Perform Source Check 31 days TRS 3.11.2.6.4 Perform CHANNEL FUNCTIONAL TEST 92 days TRS 3.11.2.6.5 Perform CHANNEL CALIBRATION 24 months SUSQUEHANNA - UNIT 1 TRM I 3.11-29 EFFECTIVE DA TE 12/03/2004

Rev. 7 Radioactive Gaseous Effluent Monitoring Instrumentation 3.11.2.6 TABLE 3.11.2.6-1 (Page 1 of 3)

RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION FUNCTION APPLICABILITY REQUIRED CHANNELS SURVEILLANCE REQUIREMENTS

1.

REACTOR BUILDING VENTILATION MONITORING SYSTEM

a.

Noble Gas Activity Monitor At all Times 1

TRS 3.11.2.6.1 (Low Range)

TRS 3.11.2.6.3 TRS 3.11.2.6.4 TRS 3.11.2.6.5

b.

Deleted C.

Deleted

d.

Effluent System Flow Rate At all Times TRS 3.11.2.6.1 Monitor TRS 3.11.2.6.4 TRS 3.11.2.6.5

e.

Sampler Flow Rate Monitor At all Times 1

TRS 3.11.2.6.1 TRS 3.11.2.6.4 TRS 3.11.2.6.5 (continued)

SUSQUEHANNA - UNIT 1 TRM I 3.11-30 EFFECTIVE DATE 01/21/2004

Rev. 7 Radioactive Gaseous Effluent Monitoring Instrumentation 3.11.2.6 TABLE 3.11.2.6-1 (Page 2 of 3)

RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION FUNCTION APPLICABILITY REQUIRED CHANNELS SURVEILLANCE REQUIREMENTS

2.

TURBINE BUILDING VENTILATION MONITORING SYSTEM

a.

Noble Gas Activity Monitor (Low Range)

b.

Deleted

c.

Deleted

d.

Effluent System Flow Rate Monitor

e.

Sample Flow Rate Monitor (Bypass)

f.

Sample Flow Rate Monitor (Low Range)

SUSQUEHANNA - UNIT 1 At all Times At all Times At all Times At all Times TRM I 3.11-31 1

1 TRS 3.11.2.6.1 TRS 3.11.2.6.3 TRS 3.11.2.6.4 TRS 3.11.2.6.5 TRS 3.11.2.6.1 TRS 3.11.2.6.4 TRS 3.11.2.6.5 TRS 3.11.2.6.1 TRS 3.11.2.6.4 TRS 3.11.2.6.5 TRS 3.11.2.6.1 TRS 3.11.2.6.4 TRS 3.11.2.6.5 (continued)

EFFECTIVE DATE 08/11/2016

Rev. 7 Radioactive Gaseous Effluent Monitoring Instrumentation 3.11.2.6 TABLE 3.11.2.6-1(Page3 of 3)

RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION FUNCTION APPLICABILITY

3.

STANDBY GAS TREATMENT SYSTEM (STGS) MONITOR

a.

Noble Gas Activity Monitor (Low Range)

b.

Deleted

c.

Deleted

d.

Effluent System Flow Rate Monitor

e.

Sample Flow Rate Monitor (Bypass)

f. Sample Flow Rate Monitor (Low Range)

(a)

TRO 3.0.4.c is applicable.

SUSQUEHANNA - UNIT 1 During operation of SGTS(a)

During operation of SGTS(a)

During operation of SGTS(a)

During operation of SGTS(a)

TRM I 3.11-32 REQUIRED CHANNELS SURVEILLANCE REQUIREMENTS TRS 3.11.2.6.1 TRS 3.11.2.6.3 TRS 3.11.2.6.4 TRS 3.11.2.6.5 TRS 3.11.2.6.1 TRS 3.11.2.6.4 TRS 3.11.2.6.5 TRS 3.11.2.6.1 TRS 3.11.2.6.4 TRS 3.11.2.6.5 TRS 3.11.2.6.1 TRS 3.11.2.6.4 TRS 3.11.2.6.5 EFFECTIVE DATE 10/06/2016