COLR Dresden 2 Revision 16 Core Operating Limits Report For Dresden Unit 2 Cycle 25 Revision 1 Page 1of57

COLR Dresden 2 Revision 16 Table of Contents Page Record of Dresden 2 Cycle 25 COLR Revisions................................................................. 3

1. Terms and Definitions.................................................................................................................. 6
2. General Information..................................................................................................................... 7
3. Average Planar Linear Heat Generation Rate............................................................................. 8
4. Operating Limit Minimum Critical Power Ratio.......................................................................... 37 4.1. Manual Flow Control MCPR Limits.................................................................................... 37 4.1.1. Power-Dependent MCPR............................................................................................ 37 4.1.2. Flow-Dependent MCPR.............................................................................................. 37 4.2. Scram Time......................................................................................................................... 38 4.3. Recirculation Pump ASD Settings...................................................................................... 38
5. Linear Heat Generation Rate..................................................................................................... 44
6. Control Rod Block Setpoints...................................................................................................... 51
7. Stability Protection Setpoints..................................................................................................... 52
8. Modes of Operation................................................................................................................... 53
9. Methodology.............................................................................................................................. 56
10. References.............................................................................................................................. 57 Page 2 of 57

COLR Dresden 2 Revision 16 Record of Dresden 2 Cycle 25 COLR Revisions Revision 0

1 Description Initial issuance for D2C25 Update Section 5, Section 8 Note 1, and associated references for transition to POWERPLEX-XD on-line core monitoring system and revise the Table 5-13 LHGRFAC(P) values at 80% for PLUOOS and TCV Slow Closure to be no greater than the Base Case limits.

Page 3 of 57

COLR Dresden 2 Revision 16 List of Tables Page Table 3-1: MAPLHGR for Lattices 81 and 89................................................................... 8 Table 3-2: MAPLHGR for Lattice 113..........................................................................

8 Table 3-3: MAPLHGR for Lattice 114........................................................................... 9 Table 3-4: MAPLHGR for Lattice 115........................................................................... 9 Table 3-5: MAPLHGR for Lattice 116........................................................................... 10 Table 3-6: MAPLHGR for Lattice 117.......................................................................... 10 Table 3-7: MAPLHGR for Lattice 118........................................................................... 11 Table 3-8: MAPLHGR for Lattice 119........................................................................... 11 Table 3-9: MAPLHGR for Lattice 120.......................................................................... 12 Table 3-10: MAPLHGR for Lattice 121........................................................................ 12 Table 3-11: MAPLHGR for Lattice 122........................................................................ 13 Table 3-12: MAPLHGR for Lattice 123........................................................................ 13 Table 3-13: MAPLHGR for Lattice 124........................................................................ 14 Table 3-14: MAPLHGR for Lattice 125........................................................................ 14 Table 3-15: MAPLHGR for Lattice 126........................................................................ 15 Table 3-16: MAPLHGR for Lattice 127........................................................................ 15 Table 3-17: MAPLHGR for Lattice 128........................................................................ 16 Table 3-18: MAPLHGR for Lattice 129........................................................................ 16 Table 3-19: MAPLHGR for Lattice 130........................................................................ 17 Table 3-20: MAPLHGR for Lattice 131........................................................................ 17 Table 3-21: MAPLHGR for Lattice 132........................................................................ 18 Table 3-22: MAPLHGR for Lattice 133........................................................................ 18 Table 3-23: MAPLHGR for Lattice 134........................................................................ 19 Table 3-24: MAPLHGR for Lattice 135........................................................................ 19 Table 3-25: MAPLHGR for Lattice 136........................................................................ 20 Table 3-26: MAPLHGR for Lattice 137........................................................................ 20 Table 3-27: MAPLHGR for Lattice 138........................................................................ 21 Table 3-28: MAPLHGR for Lattice 139........................................................................ 21 Table 3-29: MAPLHGR for Lattice 140........................................................................ 22 Table 3-30: MAPLHGR for Lattice 141.......................................................................... 22 Table 3-31: MAPLHGR for Lattice 142........................................................................ 23 Table 3-32: MAPLHGR for Lattice 143........................................................................ 23 Table 3-33: MAPLHGR for Lattice 144........................................................................ 24 Table 3-34: MAPLHGR for Lattice 145........................................................................ 24 Table 3-35: MAPLHGR for Lattice 146........................................................................ 25 Table 3-36: MAPLHGR for Lattice 147........................................................................ 25 Table 3-37: MAPLHGR for Lattice 148........................................................................ 26 Table 3-38: MAPLHGR for Lattice 149........................................................................ 26 Table 3-39: MAPLHGR for Lattice 150........................................................................ 27 Table 3-40: MAPLHGR for Lattice 151........................................................................ 27 Table 3-41: MAPLHGR for Lattice 152........................................................................ 28 Table 3-42: MAPLHGR for Lattice 153........................................................................ 28 Table 3-43: MAPLHGR for Lattice 154........................................................................ 29 Table 3-44: MAPLHGR for Lattice 155........................................................................ 29 Table 3-45: MAPLHGR for Lattice 156........................................................................ 30 Table 3-46: MAPLHGR for Lattice 157........................................................................ 30 Table 3-47: MAPLHGR for Lattice 158........................................................................ 31 Table 3-48: MAPLHGR for Lattice 159........................................................................ 31 Table 3-49: MAPLHGR for Lattice 160........................................................................ 32 Table 3-50: MAPLHGR for Lattice 161........................................................................ 32 Table 3-51: MAPLHGR for Lattice 162........................................................................ 33 Table 3-52: MAPLHGR for Lattice 163........................................................................ 33 Page 4 of 57

COLR Dresden 2 Revision 16 Page Table 3-53: MAPLHGR for Lattice 164........................................................................ 34 Table 3-54: MAPLHGR for Lattice 165........................................................................ 34 Table 3-55: MAPLHGR for Lattice 166......................................................................... 35 Table 3-56: MAPLHGR for Lattice 167........................................................................ 35 Table 3-57: MAPLHGR SLO Multiplier....................................................................... 36 Table 4-1: Scram Times............................................................................................ 38 Table 4-2: MCPR TSSS Based Operating Limits - NFWT................................................ 39 Table 4-3: MCPR TSSS Based Operating Limits - RFWT............................................... 39 Table 4-4: MCPR ISS Based Operating Limits - NFWT.................................................. 40 Table 4-5: MCPR ISS Based Operating Limits - RFWT...................................................40 Table 4-6: MCPR NSS Based Operating Limits-NFWT................................................. 41 Table 4-7: MCPR NSS Based Operating Limits-RFWT................................................. 41 Table 4-8: MCPR(P) - NFWT..................................................................................... 42 Table 4-9: MCPR(P) - RFWT......................................................................................43 Table 4-10: MCPR(F)...............................................................................................43 Table5-1: LHGR Limit for Lattices 113, 114, 115, 118, 122............................................. 44 Table 5-2: LHGR Limit for Lattice 116............................................................................45 Table 5-3: LHGR Limit for Lattices 117, 123, 124.............................................................45 Table 5-4: LHGR Limit for Lattices 119, 120, 121............................................................. 46 Table 5-5: LHGR Limit for Lattices 125*, 126*, 127*, 128*, 129*, 130*, 137, 138, 139, 143, 144, 145, 146, 147, 148, 156, 157, 158, 159, 163, 164, 165, 166, 167................ 46 Table 5-6: LHGR Limit for Lattices 135, 141...................................................................46 Table 5-7: LHGR Limit for Lattices 131, 132, 133, 136, 140, 142........................................47 Table 5-8: LHGR Limit for Lattice 134............................................................................47 Table 5-9: LHGR Limit for Lattices 154, 161...................................................................47 Table 5-10: LHGR Limit for Lattices 150, 151, 152, 155, 160, 162.......................................48 Table 5-11: LHGR Limit for Lattices 149, 153........................... **.*....................................48 Table 5-12: LHGR Limit for Lattices 81 and 89............................................................... 48 Table 5-13: LHGRFAC(P) Multipliers............................................................................49 Table 5-14: LHGRFAC(F) Multipliers............................................................................ 50 Table 6-1: Rod Block Monitor Upscale Instrumentation Setpoints...................................... 51 Table 7-1: OPRM PBDA Trip Settings......................................................................... 52 Table 8-1: Modes of Operation.................................................................................. 53 Table 8-2: Core Thermal Power Restriction for OOS Conditions........................................ 55 Page 5 of 57

COLR Dresden 2 Revision 16

1. Terms and Definitions 2TBVOOS APLHGR ASD CPR DLO EFPH EOC EOFPL EOOS FWT FWTR GWd/MTU ICF ISS LHGR LHGRFAC(F)

LHGRFAC(P)

LPRM MAPLHGR MCFL MCPR MCPR(F)

MCPR(P)

MELLLA MSIV MWd/MTU NFWT NRC NSS OLMCPR oos OPRM PBDA PLUOOS PCOOS RFWT RWE SER SLMCPR SLO TBVOOS TBV TCV TIP TMOL TSSS TSV Turbine bypass valve #8 and a second turbine bypass valve out of service Average planar linear heat generation rate Adjustable speed drive Critical power ratio Dual loop operation Effective full power hour End of cycle End of full power life Equipment out of service Feedwater temperature Feedwater temperature reduction Gigawatt days per metric ton Uranium Increased core flow Intermediate scram speed Linear heat generation rate Flow dependent linear heat generation rate multiplier Power dependent linear heat generation rate multiplier Local power range monitor Maximum average planar linear heat generation rate Max combined flow limiter Minimum critical power ratio Flow dependent minimum critical power ratio Power dependent minimum critical power ratio Maximum extended load line limit analysis Main steam isolation valve Megawatt days per metric ton Uranium Nominal feedwater temperature Nuclear Regulatory Commission Nominal scram speed Operating limit minimum critical power ratio Out of service Oscillation power range monitor Period based detection algorithm Power load unbalance out of service Pressure controller out of service Reduced feedwater temperature Rod withdrawal error Safety evaluation report Safety limit minimum critical power ratio Single loop operation Turbine bypass valves out of service Turbine bypass valve Turbine control valve Traversing in-core probe Thermal mechanical operating limit Technical Specification scram speed Turbine stop valve Page 6 of 57

COLR Dresden 2 Revision 16

2. General Information Power and flow dependent limits are listed for various power and flow levels. Linear interpolation is to be used to find intermediate values.

Licensed rated thermal power is 2957 MWth. Rated core flow is 98 Mlb/hr. Operation up to 108%

rated flow (ICF) is fully evaluated for this cycle; however, flow cannot exceed 103.4% rated flow due to unit specific limitations. For allowed operating regions, see applicable power/flow map.

The licensing analysis supports full power operation to EOFPL + 25 days (16182 MWD/MTU) and coastdown to a power of 70% given all burnup limits are satisfied (Reference 22).

Coastdown is defined as any cycle exposure beyond the full power, licensed increased core flow, and all rods out condition with the plant power gradually reducing as available core reactivity diminishes.

MCPR(P) and MCPR(F) values are independent of scram speed. MCPR(F) is independent of FWT.

LHGRFAC(P) and LHGRFAC(F) values are independent of scram speed and FWT.

All thermal limits are analyzed to NSS, ISS, and TSSS, except for the special case 2TBVOOS, which is only analyzed for NSS and NFWT (Reference 22). Only MCPR operating limits vary with scram speed.

For thermal limit monitoring above 100% rated power or 108% rated core flow, the 100% rated power or the 108% core flow thermal limit values, respectively, can be used unless otherwise indicated in the applicable table.

Page 7 of 57

COLR Dresden 2 Revision 16

3. Average Planar Linear Heat Generation Rate Technical Specifications Sections 3.2.1 and 3.4.1 For natural uranium lattices, DLO and SLO MAPLHGR values are provided in Table 3-1. For all other lattices, lattice-specific MAPLHGR values for DLO are provided in Tables 3-2 through 3-56.

During SLO, these limits are multiplied by the SLO multiplier listed in Table 3-57.

Table 3-1: MAPLHGR for Lattices 81 and 89 (Reference 9, 15, 16 and 17\\

All Bundles Lattice 81: Opt2-B0.71 89: Opt2-T0.71 Average Planar Exposure DLO and SLO MAPLHGR (MWd/MTU)

(kW/ft) 0 7.50 75000 7.50 Table 3-2: MAPLHGR for Lattice 113 (References 9, 10, and 11)

Bundle Opt2-4.05-18GZ8.00-14GZ5. 50 Lattice 113: Opt2-B4.45-18G8.00 Average Planar Exposure DLOMAPLHGR CMWd/MTU)

(kW/ft) 0 8.67 2500 8.86 5000 8.97 7500 9.04 10000 9.07 12000 9.11 15000 9.26 17000 9.38 20000 9.54 22000 9.69 24000 9.75 30000 9.68 36000 9.64 42000 9.62 50000 9.67 60000 9.66 72000 9.88 Page 8 of 57

COLR Dresden 2 Revision 16 Table 3-3: MAPLHGR for Lattice 114 (References 9 10 and 11 l Bundle Opt2-4.05-18GZ8.00-14GZ5.50 Lattice 114: 0pt2-BE4.54-18G8.00 Average Planar Exposure DLO MAPLHGR (MWd/MTU}

(kW/ft}

0 8.70 2500 8.88 5000 9.02 7500 9.08 10000 9.13 12000 9.18 15000 9.35 17000 9.47 20000 9.65 22000 9.80 24000 9.83 30000 9.76 36000 9.72 42000 9.70 50000 9.70 60000 9.70 72000 9.92 Table 3-4: MAPLHGR Lattice 115 (References 9, 10, and 11)

Bundle Opt2-4.05-18GZ8.00-14GZ5.50 Lattice 115: Opt2-M4.54-18G8.00 Average Planar Exposure DLO MAPLHGR (MWd/MTU)

(kW/ft) 0 8.68 2500 8.85 5000 9.01 7500 9.10 10000 9.14 12000 9.21 15000 9.36 17000 9.49 20000 9.66 22000 9.82 24000 9.83 30000 9.76 36000 9.71 42000 9.70 50000 9.68 60000 9.68 72000 9.93 Page 9 of 57

COLR Dresden 2 Revision 16 Table 3-5: MAPLHGR for Lattice 116

!References 9, 1 O and 11)

Bundle Opt2-4.05-18GZ8.00-14GZ5.50 Lattice 116: Opt2-ME4.50-18G8.00 Average Planar Exposure DLOMAPLHGR (MWd/MTU)

(kW/ft) 0 8.81 2500 9.00 5000 9.14 7500 9.25 10000 9.28 12000 9.36 15000 9.53 17000 9.68 20000 9.99 22000 10.03 24000 10.01 30000 9.97 36000 9.91 42000 9.90 50000 9.82 60000 9.85 72000 10.19 Table 3-6: MAPLHGR for Lattice 117 (References 9, 1 O, and 11)

Bundle Opt2-4.05-18GZ8.00-14GZ5.50 Lattice 117: Opt2-T4.50-18G8.00 Average Planar Exposure DLOMAPLHGR (MWd/MTU)

(kW/ft) 0 8.85 2500 9.03 5000 9.17 7500 9.22 10000 9.22 12000 9.28 15000 9.46 17000 9.64 20000 10.00 22000 10.00 24000 10.00 30000 9.95 36000 9.89 42000 9.87 50000 9.79 60000 9.82 72000 10.19 Page 10 of 57

COLR Dresden 2 Revision 16 Table 3-7: MAPLHGR for Lattice 118 (References9 10, and 11)

Bundle Opt2-4.05-18GZ8.00-14GZ5.50 Lattice 118: Opt2-T4.52-14G5.50 Average Planar Exposure DLOMAPLHGR (MWd/MTU)

(kW/ft) 0 9.66 2500 9.77 5000 9.79 7500 9.71 10000 9.64 12000 9.66 15000 9.95 17000 10.15 20000 10.17 22000 10.16 24000 10.14 30000 10.07 36000 10.01 42000 9.95 50000 9.85 60000 9.90 72000 10.26 Table 3-8: MAPLHGR for Lattice 119 (References 9, 10, and 11)

Bundle Opt2-4.05-16GZ8.00-14_GZ5.50 Lattice 119: Opt2-B4.46-16G8.00 II Average Planar Exposure DLO MAPLHGR (MWd/MTU)

(kW/ft) 0 8.96 2500 9.11 5000 9.19 7500 9.21 10000 9.21 12000 9.23 15000 9.33 17000 9.41 20000 9.54 22000 9.67 24000 9.77 30000 9.72 36000 9.68 42000 9.66 50000 9.67 60000 9.65 72000 9.88 Page 11 of 57

COLR Dresden 2 Revision 16 Table 3-9: MAPLHGR for Lattice 120 (References 9 1 o and 11)

Bundle Opt2-4.05-16GZ8.00-14GZ5.50 Lattice 120: Opt2-BE4.55-16G8.00 Average Planar Exposure DLO MAPLHGR (MWd/MTU)

(kW/ft) 0 9.00 2500 9.15 5000 9.25 7500 9.28 10000 9.28 12000 9.30 15000 9.41 17000 9.50 20000 9.64 22000 9.78 24000 9.86 30000 9.81 36000 9.76 42000 9.75 50000 9.69 60000 9.69 72000 9.93 Table 3-10: MAPLHGR for Lattice 121 (References 9, 10, and 11)

Bundle Opt2-4.05-16GZ8.00-14GZ5.50 Lattice 121: Opt2-M4.55-16G8.00 Average Planar Exposure DLO MAPLHGR (MWd/MTU)

(kW/ft) 0 8.99 2500 9.12 5000 9.24 7500 9.29 10000 9.28 12000 9.32 15000 9.42 17000 9.52 20000 9.65 22000 9.79 24000 9.85 30000 9.80 36000 9.76 42000 9.75 50000 9.67 60000 9.67 72000 9.93 Page 12 of 57

COLR Dresden 2 Revision 16 Table 3-11: MAPLHGR for Lattice 122 (References 9, 10, and 11)

Bundle Opt2-4.05-16GZ8.00-14GZ5.50 Lattice 122: Opt2-ME4.51-16G8.00 Average Planar Exposure DLO MAPLHGR (MWd/MTU)

(kW/ft) 0 9.14 2500 9.30 5000 9.40 7500 9.46 10000 9.44 12000 9.48 15000 9.60 17000 9.71 20000 9.96 22000 10.05 24000 10.05 30000 10.01 36000 9.96 42000 9.89 50000 9.80 60000 9.84 72000 10.19 Table 3-12: MAPLHGR for Lattice 123

<References 9, 10, and 11 l Bundle Opt2-4.05-16GZ8.00-14GZ5.50 Lattice 123: Opt2-T4.51-16G8.00 Average Planar Exposure DLO MAPLHGR (MWd/MTU)

(kW/ft) 0 9.18 2500 9.33 5000 9.42 7500 9.43 10000 9.39 12000 9.42 15000 9.54 17000 9.67 20000 9.97 22000 10.03 24000 10.03 30000 10.00 36000 9.94 42000 9.85 50000 9.77 60000 9.81 72000 10.20 Page 13 of 57

COLR Dresden 2 Revision 16 Table 3-13: MAPLHGR for Lattice 124 (References 9, 10, and 11)

Bundle Opt2-4.05-16GZ8.00-14GZ5.50 Lattice 124: Opt2-T4.52-14G5.50 Average Planar Exposure DLOMAPLHGR (MWd/MTU}

(kW/ft}

0 9.66 2500 9.77 5000 9.79 7500 9.71 10000 9.64 12000 9.66 15000 9.95 17000 10.15 20000 10.17 22000 10.16 24000 10.14 30000 10.07 36000 10.01 42000 9.95 50000 9.85 60000 9.90 72000 10.26 Table 3-14: MAPLHGR for Lattice 125 (References9, 10, and 11)

Bundle Opt2-4.10-14GZ5.50-2GZ5.50 Lattice 125: Opt2-B4.50-16G5.50 Average Planar Exposure DLO MAPLHGR (MWd/MTU)

(kW/ft) 0 8.91 2500 9.07 5000 9.20 7500

.9.26 10000 9.28 12000 9.31 15000 9.47 17000 9.65 20000 9.82 22000 9.87 24000 9.86 30000 9.79 36000 9.73 42000 9.71 50000 9.75 60000 9.73 72000 9.93 Page 14 of 57

COLR Dresden 2 Revision 16 Table 3-15: MAPLHGR for Lattice 126 (References 9, 1 O and 11)

Bundle Opt2-4.10-14GZ5.50-2GZ5.50 Lattice 126: Opt2-BE4.60-16G5.50 Average Planar Exposure DLO MAPLHGR (MWd/MTU)

(kW/ft) 0 8.95 2500 9.11 5000 9.26 7500 9.32 10000 9.34 12000 9.39 15000 9.57 17000 9.76 20000 9.93 22000 9.97 24000 9.95 30000 9.88 36000 9.83 42000 9.80 50000 9.79 60000 9.77 72000 9.98 Table 3-16: MAPLHGR for Lattice 127 (References 9, 10, and 11)

Bundle Opt2-4.10-14GZ5.50-2GZ5.50 Lattice 127: Opt2-M4.60-16G5.50 Average Planar Exposure DLO MAPLHGR (MWd/MTU)

(kW/ft) 0 8.94 2500 9.10 5000 9.25 7500 9.33 10000 9.36 12000 9.40 15000 9.58 17000 9.77 20000 9.95 22000 9.97 24000 9.95 30000 9.88 36000 9.82 42000 9.79 50000 9.77 60000 9.75 72000 9.98 Page 15 of 57

COLR Dresden 2 Revision 16 Table 3-17: MAPLHGR for Lattice 128 (References 9, 10, and 11)

Bundle Opt2-4.10-14GZ5.50-2GZ5.50 Lattice 128: Opt2-ME4.56-16G5.50 Average Planar Exposure DLO MAPLHGR (MWd/MTU)

(kW/ft) 0 9.10 2500 9.26 5000 9.42 7500 9.52 10000 9.52 12000 9.60 15000 9.87 17000 10.10 20000 10.20 22000 10.19 24000 10.17 30000 10.09 36000 10.03 42000 10.01 50000 9.92 60000 9.93 72000 10.25 Table 3-18: MAPLHGR for Lattice 129 (References 9, 10, and 11)

Bundle Opt2-4.10-14GZ5.50-2GZ5.50 Lattice 129: Opt2-T4.56-16G5.50 Average Planar Exposure DLO MAPLHGR (MWd/MTU)

(kW/ft) 0 9.14 2500 9.31 5000 9.44 7500 9.46 10000 9.46 12000 9.53 15000 9.88 17000 10.11 20000 10.19 22000 10.17 24000 10.15 30000 10.08 36000 10.01 42000 9.99 50000 9.88 60000 9.91 72000 10.25 Page 16 of 57

COLR Dresden 2 Revision 16 Table 3-19: MAPLHGR for Lattice 130

!References 9, 10, and 11)

Bundle Opt2-4.10-14GZ5.50-2GZ5.50 Lattice 130: Opt2-T4.57-14G5.50 Average Planar Exposure DLO MAPLHGR

{MWd/MTU)

{kW/ft) 0 9.50 2500 9.63 5000 9.71 7500 9.68 10000 9.61 12000 9.62 15000 9.88 17000 10.09 20000 10.21 22000 10.19 24000 10.18 30000 10.10 36000 10.04 42000 9.98 50000 9.87 60000 9.90 72000 10.25 Table 3-20: MAPLHGR for Lattice 131 (References 3 and 15)

Bundle Opt2-4.04-18GZ7.50-14GZ5.50 Lattice 131: Opt2-B4.44-18G7.50 Average Planar Exposure DLO MAPLHGR

{MWd/MTU)

(kW/ft) 0 9.21 2500 9.53 5000 9.45 7500 9.38 10000 9.49 12000 9.50 15000 9.55 17000 9.61 20000 9.80 22000 9.89 24000 9.83 30000 9.77 36000 9.71 42000 9.67 50000 9.70 60000 9.81 72000 10.07 75000 10.07 Page 17 of 57

COLR Dresden 2 Revision 16 Table 3-21: MAPLHGR for Lattice 132 (References 3 and 15)

Bundle Opt2-4.04-18GZ7.50-14GZ5.50 Lattice 132: Opt2-BE4.54-18G7.50 Average Planar Exposure DLO MAPLHGR CMWd/MTU)

(kW/ft) 0 9.34 2500 9.62 5000 9.51 7500 9.43 10000 9.55 12000 9.57 15000 9.64 17000 9.73 20000 9.89 22000 10.02 24000 9.94 30000 9.86 36000 9.81 42000 9.74 50000 9.77 60000 9.80 72000 10.10 75000 10.10 Table 3-22: MAPLHGR for Lattice 133 (References 3 and 15)

Bundle Opt2-4.04-18GZ7.50-14GZ5.50 Lattice 133: 0pt2-M4.54-18G7.50 Average Planar Exposure DLO MAPLHGR (MWd/MTU)

(kW/ft) 0 9.33 2500 9.62 5000 9.57 7500 9.43 10000 9.56 12000 9.62 15000 9.67 17000 9.75 20000 9.98 22000 9.99 24000 9.93 30000 9.85 36000 9.81 42000 9.74 50000 9.75 60000 9.78 72000 9.90 75000 9.90 Page 18 of 57

)

COLR Dresden 2 Revision 16 Table 3-23: MAPLHGR for Lattice 134 (References 3 and 15)

Bundle Opt2-4.04-18GZ7.50-14GZ5.50 Lattice 134: Opt2-ME4.50-18G7.50 Average Planar Exposure DLO MAPLHGR (MWd/MTU)

(kW/ft) 0 9.46 2500 9.77 5000 9.62 7500 9.52 10000 9.72 12000 9.73 15000 9.83 17000 9.93 20000 10.19 22000 10.19 24000 10.11 30000 10.04 36000 9.97 42000 9.92 50000 9.85 60000 9.88 72000 10.39 75000 10.39 Table 3-24: MAPLHGR for Lattice 135 (References 3 and 15)

Bundle Opt2-4.04-18GZ7.50-14GZ5.50 Lattice 135: Opt2-T4.50-18G7.50 Average Planar Exposure DLO MAPLHGR (MWd/MTU}

(kW/ft) 0 9.48 2500 9.76 5000 9.56 7500 9.45 10000 9.55 12000 9.72 15000 9.78 17000 9.94 20000 10.19 22000 10.16 24000 10.11 30000 10.05 36000 9.97 42000 9.93 50000 9.81 60000 9.84 72000 10.25 75000 10.25 Page 19 of 57

COLR Dresden 2 Revision 16 Table 3-25: MAPLHGR for Lattice 136 (References 3 and 15)

Bundle Opt2-4.04-18GZ7.50-14GZ5.50 Lattice 136: 0pt2-T4.52-14G5.50 Average Planar Exposure DLOMAPLHGR CMWd/MTUl (kW/ft) 0 10.21 2500 10.47 5000 10.28 7500 10.05 10000 10.09 12000 10.11 15000 10.22 17000 10.27 20000 10.26 22000 10.29 24000 10.22 30000 10.16 36000 10.09 42000 10.00 50000 9.87 60000 9.90 72000 10.26 75000 10.26 Table 3-26: MAPLHGR for Lattice 137 (References 3 and 15)

Bundle Opt2-4.01-16GZ7.50-14GZ5.50 Lattice 137: Opt2-B4.41-16G7.50 Average Planar Exposure DLO MAPLHGR (MWd/MTU)

(kW/ft) 0 9.47 2500 9.76 5000 9.66 7500 9.57 10000 9.64 12000 9.54 15000 9.57 17000 9.60 20000 9.76 22000 9.90 24000 9.84 30000 9.79 36000 9.75 42000 9.70 50000 9.70 60000 9.79 72000 10.07 75000 10.07 Page 20 of 57

COLR Dresden 2 Revision 16 Table 3-27: MAPLHGR for Lattice 138 (References 3 and 15)

Bundle Opt2-4.01-16GZ7.50-14GZ5.50 Lattice 138: Opt2-BE4.51-16G7.50 Average Planar Exposure DLO MAPLHGR

{MWd/MTU)

{kW/ft) 0 9.63 2500 9.85 5000 9.81 7500 9.63 10000 9.70 12000 9.70 15000 9.70 17000 9.75 20000 9.89 22000 10.00 24000 9.95 30000 9.89 36000 9.85 42000 9.77 50000 9.70 60000 9.69 72000 10.02 75000 10.02 Table 3-28: MAPLHGR for Lattice 139 (References 3 and 15)

Bundle Opt2-4.01-16GZ7.50-14GZ5.50 Lattice 139: Opt2-M4.51-16G7.50 Average Planar Exposure DLOMAPLHGR (MWd/MTU)

(kW/ft) 0 9.62 2500 9.87 5000 9.91 7500 9.63 10000 9.72 12000 9.74 15000 9.73 17000 9.77 20000 9.91 22000 10.00 24000 9.95 30000 9.88 36000 9.85 42000 9.77 50000 9.68 60000 9.68 72000 10.06 75000 10.06 Page 21 of 57

COLR Dresden 2 Revision 16 Table 3-29: MAPLHGR for Lattice 140 (References 3 and 15)

Bundle Opt2-4.01-16GZ7.50-14GZ5.50 Lattice 140: Opt2-ME4.46-16G7.50 Average Planar Exposure DLOMAPLHGR (MWd/MTU)

(kW/ft) 0 9.78 2500 10.04 5000 9.96 7500 9.80 10000 9.89 12000 9.89 15000 9.89 17000 9.94 20000 10.17 22000 10.19 24000 10.14 30000 10.08 36000 10.01 42000 9.92 50000 9.80 60000 9.84 72000 10.25 75000 10.25 Table 3-30: MAPLHGR for Lattice 141 (References 3 and 15)

Bundle Opt2-4.01-16GZ7.50-14GZ5.50 Lattice 141: Opt2-T4.46-16G7.50 Average Planar Exposure DLOMAPLHGR (MWd/MTU)

(kW/ft) 0 9.80 2500 10.02 5000 9.87 7500 9.76 10000 9.84 12000 9.84 15000 9.83 17000 9.95 20000 10.16 22000 10.15 24000 10.13 30000 10.08 36000 10.00 42000 9.88 50000 9.77 60000 9.71 72000 9.91 75000 9.91 Page 22 of 57

COLR Dresden 2 Revision 16 Table 3-31: MAPLHGR for Lattice 142 References 3 and 15 Bundle Opt2-4.01-16GZ7.50-14GZ5.50 Lattice 142: Opt2-T4.47-14G5.50 Average Planar Exposure DLO MAPLHGR MWd/MTU kW/ft) 0 1Q~

2500 10.45 5000 10.32 7500 10.07 10000 10.01 12000 10.11 15000 10.23 17000 10.25 20000 10.23 22000 10.23 24000 10.19 30000 10.14 36000 10.07 42000 9.96 50000 9.84 60000 9.87 72000 10.26 75000 10.26 Table 3-32: MAPLHGR for Lattice 143 References 3 and 15 Bundle Opt2-4.04-14G5.50-2GZ5.50 Lattice 143: Opt2-B4.44-16G5.50 Average Planar Exposure DLO MAPLHGR (MWd/MTU)

(kW/ft) 0 9.48 2500 9.78 5000 9.79 7500 9.59 10000 9.69 12000 9.63 15000 9.75 17000 9.83 20000 10.01 22000 9.95 24000 9.90 30000 9.84 36000 9.79 42000 9.74 50000 9.72 60000 9.77 72000 9.85 75000 9.79 Page 23 of 57

COLR Dresden 2 Revision 16 Table 3-33: MAPLHGR for Lattice 144 (References 3 and 15)

Bundle Opt2-4.04-14G5.50-2GZ5.50 Lattice 144: Opt2-BE4.54-16G5.50 Average Planar Exposure DLOMAPLHGR (MWd/MTU)

(kW/ft) 0 9.55 2500 9.87 5000 10.02 7500 9.74 10000 9.78 12000 9.76 15000 9.89 17000 10.00 20000 10.15 22000 10.07 24000 10.02 30000 9.94 36000

'9.91 42000 9.87 50000 9.84 60000 9.94 72000 10.19 75000 10.19 Table 3-34: MAPLHGR for Lattice 145 (References 3 and 15)

Bundle Opt2-4.04-14G5.50-2GZ5.50 Lattice 145:0pt2-M4.54-16G5.50 Average Planar Exposure DLOMAPLHGR (MWd/MTU)

(kW/ft) 0 9.54 2500 9.87 5000 10.06 7500 9.85 10000 9.80 12000 9.80 15000 9.91 17000 10.04 20000 10.13 22000 10.07 24000 10.02 30000 9.94 36000 9.91 42000 9.87 50000 9.82 60000 9.94 72000 10.19 75000 10.19 Page 24 of 57

COLR Dresden 2 Revision 16 Table 3-35: MAPLHGR for Lattice 146 (References 3 and 15\\

Bundle Opt2-4.04-14G5.50-2GZ5.50 Lattice 146: Opt2-ME4.50-16G5.50 Average Planar Exposure DLO MAPLHGR

{MWd/MTU)

{kW/ft) 0 9.70 2500 10.04 5000 10.15 7500 9.87 10000 9.96 12000 9.96 15000 10.18 17000 10.32 20000 10.34 22000 10.26 24000 10.23 30000 10.15 36000 10.09 42000 10.04 50000 9.88 60000 9.88 72000 10.30 75000 10.30 Table 3-36: MAPLHGR for Lattice 147 (References 3 and 15)

Bundle Opt2-4.04-14G5.50-2GZ5.50 Lattice 147: Opt2-T4.50-16G5.50

.anar Exposure DLO MAPLHGR

{MWd/MTU)

{kW/ft) 0 9.74 2500 10.06 5000 10.08 7500 9.84 10000 9.92 12000 9.93 15000 10.14 17000 10.31 20000 10.25 22000 10.24 24000 10.20 30000 10.14 36000 10.07 42000 10.00 50000 9.85 60000 9.87 72000 10.25 75000 10.25 Page 25 of 57

COLR Dresden 2 Revision 16 Table 3-37: MAPLHGR for Lattice 148 (References 3 and 15)

Bundle Opt2-4.04-14G5.50-2GZ5.50 Lattice 148: Opt2-T4.51-14G5.50 Average Planar Exposure DLO MAPLHGR (MWd/MTU)

CkW/ftl 0

10.14 2500 10.42 5000 10.48 7500 10.06 10000 10.08 12000 10.07 15000 10.15 17000 10.27 20000 10.26 22000 10.30 24000 10.23 30000 10.17 36000 10.10 42000 9.98 50000 9.84 60000 9.77 72000 10.39 75000 10.39 Table 3-38: MAPLHGR for Lattice 149 (References 16 and 17)

Bundle Opt2-4.02-18GZ7.50-14GZ5.50 Lattice 149: Opt2-B4.31-18G7.50 Average Planar Exposure DLO MAPLHGR (MWd/MTU)

(kW/ft) 0 9.51 2500 9.85 5000 9.92 7500 9.84 10000 10.09 12000 10.18 15000 10.32 17000 10.37 20000 10.43 22000 10.39 24000 10.41 30000 10.24 36000 10.12 42000 9.99 50000 9.89 75000 9.89 Page 26 of 57

COLR Dresden 2 Revision 16 Table 3-39: MAPLHGR for Lattice 150 (References 16 and 17)

Bundle Opt2-4.02-18GZ7.50-14GZ5.50 Lattice 150: Opt2-B4.44-18G7.50 Average Planar Exposure DLO MAPLHGR (MWd/MTU)

(kW/ft) 0 9.42 2500 9.75 5000 9.65 7500 9.57 10000 9.69 12000 9.72 15000 9.77 17000 9.84 20000 10.04 22000 10.14 24000 10.08 30000 10.02 36000 9.97 42000 9.93 50000 9.97 75000 9.97 Table 3-40: MAPLHGR for Lattice 151 (References 16 and 17)

Bundle Opt2-4.02-18GZ7.50-14GZ5.50 Lattice 151: Opt2-BE4.54-18G7.50 Average Planar Exposure DLO MAPLHGR

{MWd/MTU)

{kW/ft) 0 9.55 2500 9.83 5000 9.72 7500 9.62 10000 9.75 12000 9.78 15000 9.87 17000 9.96 20000 10.12 22000 10.26 24000 10.19 30000 10.11 36000 10.07 42000 10.01 50000 10.04 75000 10.04 Page 27 of 57

COLR Dresden 2 Revision 16 Table 3-41: MAPLHGR for Lattice 152 (References 16 and 17)

Bundle Opt2-4.02-18GZ7.50-14GZ5.50 Lattice 152: Opt2-M4.54-18G7.50 Average Planar Exposure DLO MAPLHGR CMWd/MTU)

(kW/ft) 0 9.54 2500 9.84 5000 9.79 7500 9.62 10000 9.75 12000 9.82 15000 9.90 17000 9.98 20000 10.20 22000 10.24 24000 10.17 30000 10.10 36000 10.06 42000 10.00 50000 10.02 75000 10.02 Table 3-42: MAPLHGR for Lattice 153 (References 16 and 17)

Bundle Opt2-4.02-18GZ7.50-14GZ5.50 Lattice 153: Opt2-ME4.50-18G7.50 Average Planar Exposure DLO MAPLHGR

{MWd/MTU)

(kW/ft) 0 9.67 2500 10.00 5000 9.83 7500 9.72 10000 9.92 12000 9.94 15000 10.05 17000 10.16 20000 10.45 22000 10.43 24000 10.36 30000 10.30 36000 10.23 42000 10.19 50000 10.13 75000 10.13 Page 28 of 57

COLR Dresden 2 Revision 16 Table 3-43: MAPLHGR for Lattice 154 (References 16 and 17)

Bundle Opt2-4.02-18GZ7.50-14GZ5.50 Lattice 154: Opt2-T4.50-18G7.50 Average Planar Exposure DLOMAPLHGR (MWd/MTU)

(kW/ft) 0 9.70 2500 9.98 5000 9.77 7500 9.64 10000 9.75 12000 9.93 15000 10.00 17000 10.16 20000 10.43 22000 10.40 24000 10.35 30000 10.30 36000 10.23 42000 10.19 50000 10.09 75000 10.09 Table 3-44: MAPLHGR for Lattice 155 (References 16 and 17)

Bundle Opt2-4.02-18GZ7.50-14GZ5.50 Lattice 155: Opt2-T4.52-14G5.50 Average Planar Exposure DLO MAPLHGR (MWd/MTU)

(kW/ft) 0 10.40 2500 10.71 5000 10.55 7500 10.25 10000 10.30 12000 10.32 15000 10.45 17000 10.52 20000 10.51 22000 10.52 24000 10.47 30000 10.41 36000 10.35 42000 10.27 50000 10.16 75000 10.16 Page 29 of 57

COLR Dresden 2 Revision 16 Table 3-45: MAPLHGR for Lattice 156 (References 16 and 17)

Bundle Opt2-3.98-16GZ7.50-14GZ5.50 Lattice 156: Opt2-B4.27-16G7.50 Average Planar Exposure DLO MAPLHGR

{MWd/MTU)

{kW/ft) 0 9.78 2500 10.09 5000 10.14 7500 10.04 10000 10.20 12000 10.25 15000 10.34 17000 10.38 20000 10.41 22000 10.44 24000 10.45 30000 10.19 36000 10.07 42000 9.94 50000 9.84 75000 9.84 Table 3-46: MAPLHGR for Lattice 157 (References 16 and 17)

Bundle Opt2-3.98-16GZ7.50-14GZ5.50 Lattice 157: Opt2-B4.41-16G7.50 Average Planar Exposure DLO MAPLHGR (MWd/MTU)

(kW/ft) 0 9.69 2500 9.99 5000 9.88 7500 9.76 10000 9.83 12000 9.76 15000 9.79 17000 9.83 20000 10.00 22000 10.13 24000 10.09 30000 10.04 36000 10.00 42000 9.95 50000 9.95 75000 9.95 Page 30 of 57

COLR Dresden 2 Revision 16 Table 3-47: MAPLHGR for Lattice 158 (References 16 and 17\\

Bundle Opt2-3.98-16GZ7.50-14GZ5.50 Lattice 158: Opt2-BE4.51-16G7.50 Average Planar Exposure DLO MAPLHGR (MWd/MTU)

{kW/ft) 0 9.84 2500 10.08 5000 10.02 7500 9.82 10000 9.90 12000 9.92 15000 9.92 17000 9.98 20000 10.13 22000 10.24 24000 10.20 30000 10.14 36000 10.10 42000 10.04 50000 9.71 75000 9.71 Table 3-48: MAPLHGR for Lattice 159 (References 16 and 17)

Bundle Opt2-3.98-16GZ7.50-14GZ5.50 Lattice 159: Opt2-M4.51-16G7.50 Average Planar Exposure DLO MAPLHGR (MWd/MTU)

(kW/ft) 0 9.84 2500 10.09 5000 10.12 7500 9.83 10000 9.91 12000 9.96 15000 9.95 17000 10.00 20000 10.14 22000 10.24 24000 10.19 30000 10.13 36000 10.10 42000 10.03 50000 9.93 75000 9.93 Page 31 of 57

COLR Dresden 2 Revision 16 Table 3-49: MAPLHGR for Lattice 160 (References 16 and 17)

Bundle Opt2-3.98-16GZ7.50-14GZ5.50 Lattice 160: Opt2-ME4.46-16G7.50 Average Planar Exposure DLO MAPLHGR (MWd/MTU)

(kW/ft) 0 10.01 2500 10.27 5000 10.19 7500 10.00 10000 10.10 12000 10.11 15000 10.11 17000 10.17 20000 10.42 22000 10.42 24000 10.39 30000 10.33 36000 10.27 42000 10.19 50000 10.08 75000 10.08 Table 3-50: MAPLHGR for Lattice 161 (References 16 and 17)

Bundle Opt2-3.98-16GZ7.50-14GZ5.50 Lattice 161: Opt2-T4.46-16G7.50 Average Planar Exposure DLO MAPLHGR (MWd/MTU)

(kW/ft) 0 10.03 2500 10.26 5000 10.09 7500 9.97 10000 10.04 12000 10.05 15000 10.06 17000 10.18 20000 10.40 22000 10.40 24000 10.37 30000 10.33 36000 10.26 42000 10.15 50000 10.00 75000 10.00 Page 32 of 57

COLR Dresden 2 Revision 16 Table 3-51: MAPLHGR for Lattice 162 (References 16 and 17)

Bundle Opt2-3.98-16GZ7.50-14GZ5.50 Lattice 162: Opt2-T4.47-14G5.50 Average Planar Exposure DLOMAPLHGR (MWd/MTU}

(kW/ft}

0 10.41 2500 10.69 5000 10.54 7500 10.28 10000 10.20 12000 10.32 15000 10.46 17000 10.49 20000 10.48 22000 10.47 24000 10.44 30000 10.39 36000 10.33 42000 10.22 50000 10.12 75000 10.12 Table 3-52: MAPLHGR for Lattice 163 (References 16 and 17)

Bundle Opt2-4.10-14G5.50-2GZ5.50 Lattice 163: 0pt2-B4.50-16G5.50 Average Planar Exposure DLOMAPLHGR (MWd/MTU)

(kW/ft) 0 9.47 2500 9.81 5000 9.71 7500 9.58 10000 9.68 12000 9.73 15000 9.89 17000 10.00 20000 10.18 22000 10.21 24000 10.18 30000 10.12 36000 10.07 42000 10.00 50000 10.02 75000 10.02 Page 33 of 57

COLR Dresden 2 Revision 16 Table 3-53: MAPLHGR for Lattice 164 (References 16 and 17)

Bundle Opt2-4.10-14G5.50-2GZ5.50 Lattice 164: Opt2-BE4.60-16G5.50 Average Planar Exposure DLO MAPLHGR (MWd/MTUl (kW/ft) 0 9.53 2500 9.89 5000 9.85 7500 9.83 10000 9.76 12000 9.82 15000 10.01 17000 10.16 20000 10.33 22000 10.34 24000 10.31 30000 10.23 36000 10.18 42000 10.14 50000 10.09 75000 10.09 Table 3-54: MAPLHGR for Lattice 165 (References 16 and 17)

Bundle Opt2-4.10-14G5.50-2GZ5.50 Lattice 165: 0pt2-M4.60-16G5.50 Average Planar Exposure DLO MAPLHGR (MWd/MTU)

(kW/ft) 0 9.51 2500 9.91 5000 9.89 7500 9.85 10000 9.78 12000 9.85 15000 10.02 17000 10.18 20000 10.36 22000 10.36 24000 10.31 30000 10.23 36000 10.18 42000 10.14 50000 10.09 75000 10.09 Page 34 of 57

COLR Dresden 2 Revision 16 Table 3-55: MAPLHGR for Lattice 166 (References 16 and 17)

Bundle Opt2-4.10-14G5.50-2GZ5.50 Lattice 166: Opt2-ME4.57-16G5.50 Average Planar Exposure DLO MAPLHGR (MWd/MTU)

(kW/ft) 0 9.68 2500 10.09 5000 10.04 7500 9.93 10000 9.95 12000 10.03 15000 10.31 17000 10.47 20000 10.62 22000 10.56 24000 10.51 30000 10.44 36000 10.37 42000 10.28 50000 10.22 75000 10.22 Table 3-56: MAPLHGR for Lattice 167 (References 16 and 17)

Bundle Opt2-4.10-14G5.50-2GZ5.50 Lattice 167: Opt2-T4.58-14G5.50 Average Planar Exposure DLO MAPLHGR (MWd/MTU)

(kW/ft) 0 10.13 2500 10.45 5000 10.44 7500 10.17 10000 10.08 12000 10.10 15000 10.29 17000 10.44 20000 10.56 22000 10.56 24000 10.52 30000 10.46 36000 10.39 42000 10.31 50000 10.17 75000 10.17 Page 35 of 57

COLR Dresden 2 Revision 16 Table 3-57: MAPLHGR SLO Multiplier (References 3, 11, and 16)

EOOS Condition Multiplier SLO 0.86 Page 36 of 57

COLR Dresden 2 Revision 16

4. Operating Limit Minimum Critical Power Ratio Technical Specification Sections 3.2.2. 3.4.1. and 3.7.7 The OLMCPRs for D2C25 were established to protect the SLMCPR for abnormal operational occurrences. The SLMCPR values for DLO and SLO for D2C25 were determined to be 1.12 and
1. 14 (Reference 22), respectively, which are unchanged from the NRG-approved values for the previous operating cycle (D2C24).

4.1. Manual Flow Control MCPR Limits The OLMCPR is determined for a given power and flow condition by evaluating the power-dependent MCPR and the flow-dependent MCPR and selecting the greater of the two.

4.1.1. Power-Dependent M.CPR For operation at less than or equal to 38.5% core thermal power, the power dependent OLMCPR is shown in Tables 4-8 and 4-9. For operation at greater than 38.5% core thermal power, the power dependent OLM CPR is determined by multiplying the applicable rated condition OLMCPR limit shown in Tables 4-2 through 4-7 by the applicable OLMCPR multiplier given in Tables 4-8 and 4-9.

4.1.2. Flow-Dependent MCPR Table 4-10 gives the MCPR(F) limit as a function of the flow based on the applicable plant condition. The flow-dependent OLMCPR values are applicable to all base case and EOOS combinations.

Page 37 of 57

COLR Dresden 2 Revision 16 4.2. Scram Time TSSS, ISS, and NSS refer to scram speeds. The scram time values associated with these speeds are shown in Table 4-1. The TSSS scram times shown in Table 4-1 are the same as those specified in the Technical Specifications (Reference 5). Reference 22 indicates that the TSSS control rod insertion times that were actually used in the transient analysis are conseNative with respect to the scram times specified in the Technical Specifications.

To utilize the OLMCPR limits for NSS in Tables 4-6 and 4-7, the average control rod insertion time at each control rod insertion fraction must be equal to or less than the NSS time shown in Table 4-1 below.

To utilize the OLMCPR limits for ISS in Tables 4-4 and 4-5, the average control rod insertion time at each control rod insertion fraction must be equal to or less than the ISS time shown in Table 4-1 below.

To utilize the OLMCPR limits for TSSS in Tables 4-2 and 4-3, the average control rod insertion time at each control rod insertion fraction must be equal to or less than the TSSS time shown in Table 4-1 below.

The "Average Control Rod Insertion Time" is defined as the sum of the control rod insertion times of all operable control rods divided by the number of operable control rods. The time for inoperable drives fully inserted (notch 00) can be conseNatively included for calculation of core average scram speed. (Reference 22)

Control Rod Insertion Fraction

(%)

5 20 50 90 Table 4-1: Scram Times (References 5 and 22)

TSSS (seconds)

ISS (seconds) 0.48 0.360 0.89 0.720 1.98 1.580 3.44 2.740 4.3. Recirculation Pump ASD Settings Technical Requirements Manual 2.1.a.1 NSS (seconds) 0.324 0.700 1.510 2.635 Cycle 25 was analyzed with a maximum core flow runout of 110%; therefore the recirculation pump ASD must be set to maintain core flow less than 110% (107.8 Mlb/hr) for all runout events (Reference 13). This value is consistent with the analyses in Reference 22.

Page 38 of 57

COLR Dresden 2 Revision 16 Table 4-2: MCPR TSSS Based Operating Limits - NFWT (Reference 22)

Cycle Exposure s 14500

> 14500 EOOS Combination MWd/MTU MWd/MTU Base 1.64 1.71 Base SLO 1.67 1.75 PLUOOS 1.70 1.76 PLUOOS SLO 1.74 1.80 TBVOOS 1.77 1.80 TBVOOS SLO 1.81 1.84 TCV Slow Closure 1.74 1.80 TCV Slow Closure SLO 1.78 1.84 TCV Stuck Closed 1.64 1.71 TCV Stuck Closed SLO 1.67 1.75 Table 4-3: MCPR TSSS Based Operating Limits - RFWT (Reference 22)

Cycle Exposure s 14500

> 14500 EOOS Combination MWd/MTU MWd/MTU Base 1.64 1.71 Base SLO 1.67 1.75 PLUOOS 1.70 1.76 PLUOOS SLO 1.74 1.80 TBVOOS 1.79 1.82 TBVOOS SLO 1.83 1.86 TCV Slow Closure 1.74 1.80 TCV Slow Closure SLO 1.78 1.84 TCV Stuck Closed 1.64 1.71 TCV Stuck Closed SLO 1.67 1.75 Page 39 of 57

COLR Dresden 2 Revision 16 Table 4-4: MCPR ISS Based Operating Limits - NFWT (Reference 22)

Cycle Exposure

s; 14500

> 14500 EOOS Combination MWd/MTU MWd/MTU Base 1.46 1.48 Base SLO 1.49 1.51 PLUOOS 1.50 1.55 PLUOOS SLO 1.53 1.58 TBVOOS 1.55 1.60 TBVOOS SLO 1.58 1.63 TCV Slow Closure 1.52 1.57 TCV Slow Closure SLO 1.55 1.60 TCV Stuck Closed 1.46 1.48 TCV Stuck Closed SLO 1.49 1.51 Table 4-5: MCPR ISS Based Operating Limits - RFWT (Reference 22)

Cycle Exposure

s; 14500

> 14500 EOOS Combination MWd/MTU MWd/MTU Base 1.50 1.51 Base SLO 1.53 1.54 PLUOOS 1.50 1.55 PLUOOS SLO 1.53 1.58 TBVOOS 1.59 1.63 TBVOOS SLO 1.62 1.66 TCV Slow Closure 1.52 1.57 TCV Slow Closure SLO 1.55 1.60 TCV Stuck Closed 1.50 1.51 TCV Stuck Closed SLO 1.53 1.54 Page 40 of 57

COLR Dresden 2 Revision 16 Table 4-6: MCPR NSS Based Operating Limits - NFWT (Reference 22)

Cycle Exposure

14500

> 14500 EOOS Combination MWd/MTU MWd/MTU Base 1.46 1.46 Base SLO 1.49 1.49 2TBVOOS*

1.46 1.47 2TBVOOS SLO*

1.49 1.50 PLUOOS 1.49 1.53 PLUOOS SLO 1.52 1.56 TBVOOS 1.54 1.58 TBVOOS SLO 1.57 1.61 TCV Slow Closure 1.50 1.55 TCV Slow Closure SLO 1.53 1.58 TCV Stuck Closed 1.46 1.46 TCV Stuck Closed SLO 1.49 1.49

  • The 2TBVOOS EOOS option for DLO and SLO is only available for NSS at NFWT.

Table 4-7: MCPR NSS Based Operating Limits - RFWT (Reference 22)

Cycle Exposure s 14500

> 14500 EOOS Combination MWd/MTU MWd/MTU Base 1.50 1.51 Base SLO 1.53 1.54 PLUOOS 1.50 1.53 PLUOOS SLO 1.53 1.56 TBVOOS 1.58 1.61 TBVOOS SLO 1.61 1.64 TCV Slow Closure 1.50 1.55 TCV Slow Closure SLO 1.53 1.58 TCV Stuck Closed 1.50 1.51 TCV Stuck Closed SLO 1.53 1.54 Page 41 of 57

Core EOOS Combination Flow

(%of rated)

.:':_60 Base

> 60 Base SLO

.:':_60

> 60 2TBVOOS*

.:':_60

> 60 2TBVOOS SLO*

.:':_60

> 60 PLUOOS

.:':_60

>60

.:':_60 PLUOOS SLO

> 60

.:':_60 TBVOOS

> 60

.:':_60 TBVOOS SLO

>60

.:':_60 TCV Slow Closure

> 60 TCV Slow Closure SLO

.:':_60

> 60

.:':_60 TCV Stuck Closed

> 60

.:':_60 TCV Stuck Closed SLO

> 60 COLR Dresden 2 Revision 16 Table 4-8: MCPR(P) - NFWT (Reference 22)

Core Thermal Power (% of rated) 0 I 25

~38.5 >38.5 50 60 80 100 Operating Limit MCPR Operating Limit MCPR l\\!lultiplier 3.02 2.46 2.16 3.21 2.71 2.44 1.35 1.21 1.14 1.06 1.00 3.08 2.51 2.20 3.27 2.76 2.49 3.02 2.46 2.22 3.21 2.71 2.44 1.35 1.21 1.14 1.06 1.00 3.08 2.51 2.26 3.27 2.76 2.49 3.02 2.46 2.16 3.21 2.71 2.44 1.60 1.48 1.28 1.06 1.00 3.08 2.51 2.20 3.27 2.76 2.49 4.47 3.19 2.50 4.47 3.35 2.88 1.35 1.21 1.14 1.06 1.00 4.55 3.25 2.55 4.55 3.41 2.94 3.02 2.46 2.16 3.21 2.71 2.44 1.60 1.48 1.28 1.06 1.00 3.08 2.51 2.20 3.27 2.76 2.49 3.02 2.46 2.16 3.21 2.71 2.44 1.35 1.21 1.14 1.06 1.00 3.08 2.51 2.20 3.27 2.76 2.49

  • The 2TBVOOS EOOS option for DLO and SLO is only available for NSS at NFWT.

Page 42 of 57

EOOS Combination Base Base SLO PLUOOS PLUOOS SLO TBVOOS TBVOOS SLO TCV Slow Closure TCV Slow Closure SLO TCV Stuck Closed TCV Stuck Closed SLO Core Flow

(%of COLR Dresden 2 Revision 16 Table 4-9: MCPR(P) - RFWT (Reference 22)

Core Thermal Power (% of rated) 0 I 25

~38.5 >38.5 50 60 80 100 rated)

Operating Limit MCPR Operating Limit MCPR Multiplier

_60 3.02 2.46 2.16

>60 3.21 2.71 2.44

_60 3.08 2.51 2.20

>60 3.27 2.76 2.49

_60 3.02 2.46 2.16

> 60 3.21 2.71 2.44

_60 3.08 2.51 2.20

>60 3.27 2.76 2.49

_60 4.78 3.37 2.61

>60 4.78 3.37 2.95

_60 4.87 3.44 2.66

>60 4.87 3.44 3.01

_60 3.02 2.46 2.16

>60 3.21 2.71 2.44

_60 3.08 2.51 2.20

>60 3.27 2.76 2.49

_60 3.02 2.46 2.16

>60 3.21 2.71 2.44

_60 3.08 2.51 2.20

>60 3.27 2.76 2.49 Table 4-10: MCPR(F)

(Reference 22)

Flow(% of98 DLO Mlb/hr) 0 1.98 100 1.38 108 1.38 Page 43 of 57 1.40 1.24 1.16 1.06 1.00 1.60 1.48 1.28 1.06 1.00 1.40 1.24 1.16 1.06 1.00 1.60 1.48 1.28 1.06 1.00 1.40 1.24 1.16 1.06 1.00 SLO 2.02 1.41 1.41

COLR Dresden 2 Revision 16

5. Linear Heat Generation Rate Technical Specification Sections 3.2.3 and 3.4.1 The TMOL at rated conditions is established in terms of the maximum LHGR as a function of rod nodal exposure. The limits in Table 5-5 apply to bundle lattices that do not require Gadolinia set down penalties. The limits in Table 5-12 apply to the natural Uranium blankets at the top and bottom of all fuel types. The limits in all other tables apply to bundle lattices that require Gadolinia set down penalties.

The LHGR limit is the product of the exposure dependent LHGR limit from Table 5-1 through Table 5-12 as appropriate and the minimum of the power dependent LHGR Factor, LHGRFAC(P), and the flow dependent LHGR Factor, LHGRFAC(F). The LHGRFAC(P) is determined from Table 5-13. The LHGRFAC(F) is determined from Table 5-14, and is applicable for DLO, SLO, and all Base Case and EOOS conditions.

Table 5-1: LHGR Limit for Lattices 113, 114, 115, 118, 122 (References 9 and 22)

Rod Nodal Exposure LHGR Limit (GWd/MTU)

(kW/ft) 0.000 13.72 14.000 13.11 14.001 12.72 23.000 11.85 46.000 9.66 46.001 9.95 57.000 8.87 62.000 8.38 75.000 3.43 Page 44 of 57

COLR Dresden 2 Revision 16 Table 5-2: LHGR Limit for Lattice 116 (References 9 and 22)

Rod Nodal Exposure LHGR Limit (GWd/MTU)

(kW/ft) 0.000 13.72 14.000 13.11 14.001 12.65 23.000 11.79 35.000 10.65 35.001 11.04 57.000 8.87 62.000 8.38 75.000 3.43 Table 5-3: LHGR Limit for Lattices 117, 123, 124 (References 9 and 22)

Rod Nodal Exposure LHGR Limit (GWd/MTU)

(kW/ft) 0.000 13.72 14.000 13.11 18.000 12.71 18.001 12.46 23.000 11.98 46.000 9.75 46.001 9.95 57.000 8.87 62.000 8.38 75.000 3.43 Page 45 of 57

COLR Dresden 2 Revision 16 Table 5-4: LHGR Limit for Lattices 119, 120, 121 (References 9 and 22)

Rod Nodal Exposure LHGRLimit (GWd/MTU)

(kW/ft) 0.000 13.72 14.000 13.11 22.000 12.32 22.001 12.20 23.000 12.10 26.000 11.81 26.001 I

11.92 57.000 8.87 62.000 8.38 75.000 3.43 Table 5-5: LHGR Limit for Lattices 125*, 126*, 127*, 128*, 129*, 130*, 137, 138, 139, 143, 144, 145,146,147,148,156,157,158,159,163,164,165,166,167 (References 9, 15, 17, 20, 21, and 22)

Rod Nodal Exposure LHGRLimit (GWd/MTU)

(kW/ft) 0.000 13.72 14.000 13.11 23.000 12.22 57.000 8.87 62.000 8.38 75.000 3.43

  • Limits for Lattice 125, 126, 127, 128, 129, and 130 from Reference 22.

Table 5-6: LHGR Limit for Lattices 135, 141 (References 15 and 20)

Rod Nodal Exposure LHGRLimit (GWd/MTU)

(kW/ft) 0.000 13.72 14.000 13.11 22.000 12.32 22.001 12.20 23.000 12.10 35.000 10.93 35.001 11.04 57.000 8.87 62.000 8.38 75.000 3.43 Page 46 of 57

COLR Dresden 2 Revision 16 Table 5-7: LHGR Limit for Lattices 131, 132, 133, 136, 140, 142 (References 15 and 20)

Rod Nodal Exposure LHGR Limit (GWd/MTU)

(kW/ft) 0.000 13.72 14.000 13.11 14.001 12.85 23.000 11.98 46.000 9.75 46.001 9.95 57.000 8.87 62.000 8.38 75.000 3.43 Table 5-8: LHGR Limit for Lattice 134 (References 15 and 20)

Rod Nodal Exposure LHGR Limit (GWd/MTU)

(kW/ft) 0.000 13.72 14.000 13.11 14.001 12.72 23.000 11.85 35.000 10.71 35.001 11.04 57.000 8.87 62.000 8.38 75.000 3.43 Table 5-9: LHGR Limit for Lattices 154, 161 (References 17 and 21)

Rod Nodal Exposure LHGR Limit (GWd/MTU)

(kW/ft) 0.000 13.72 14.000 13.11 23.000 12.22 23.001 12.10 33.000 11.12 33.001 11.23 57.000 8.87 62.000 8.38 75.000 3.43 Page 47 of 57

COLR Dresden 2 Revision 16 Table 5-10: LHGR Limit for Lattices 150, 151, 152, 155, 160, 162 (References 17 and 21)

Rod Nodal Exposure LHGR Limit (GWd/MTU)

(kW/ft) 0.000 13.72 14.000 13.11 14.001 12.85 23.000 11.98 46.000 9.75 46.001 9.95 57.000 8.87 62.000 8.38 75.000 3.43 Table 5-11: LHGR Limit for Lattices 149, 153 (References 17 and 21)

Rod Nodal Exposure LHGR Limit (GWd/MTU)

(kW/ft) 0.000 13.72 14.000 13.11 15.000 13.01 15.001 12.62 23.000 11.85 33.000 10.90 33.001 11.23 57.000 8.87 62.000 8.38 75.000 3.43 Table 5-12: LHGR Limit for Lattices 81, 89 (Reference 22)

Rod Nodal Exposure LHGR Limit (GWd/MTU)

(kW/ft) 0.000 11.96 14.000 11.43 23.000 10.66 57.000 8.87 62.000 8.38 75.000 3.43 Page 48 of 57

COLR Dresden 2 Revision 16 Table 5-13: LHGRFAC(P) Multipliers (Reference 22)

Core Thermal Power (% of rated)

EOOS Combination 0

25

~38.5 > 38.5 50 60 80 Base 0.54 0.64 0.69 0.73 0.80 0.84 0.90 Base SLO 2TBVOOS*

0.54 0.64 0.69 0.73 0.80 0.84 0.90 2TBVOOS SLO*

PLUOOS 0.54 0.64 0.69 0.69 0.73 0.82 0.90 PLUOOS SLO TBVOOS 0.33 0.46 0.53 0.69 0.75 0.78 0.84 TBVOOS SLO TCV Slow Closure 0.54 0.64 0.69 0.69 0.73 0.82 0.90 TCV Slow Closure SLO TCV Stuck Closed 0.54 0.64 0.69 0.73 0.80 0.84 0.90 TCV Stuck Closed SLO 100 1.00 1.00 1.00 1.00 1.00 1.00

  • The 2TBVOOS EOOS Option for DLO and SLO are only available for NSS at NFWT.

Page 49 of 57

COLR Dresden 2 Revision 16 Table 5-14: LHGRFAC(F) Multipliers (Reference 22)

EOOS Condition Flow (% of 98 Mlb/hr) 0 20 40 60 80 Base Case and all EOOS Conditions 0.27 0.43 0.60 0.80 1.00 Page 50 of 57 100 108 1.00 1.00

COLR Dresden 2 Revision 16

6. Control Rod Block Setpoints Technical Specification Sections 3.3.2.1 and 3.4.1 The Rod Block Monitor Upscale Instrumentation Setpoints are determined from the relationships shown below:

Table 6-1: Rod Block Monitor Upscale Instrumentation Setpoints (Reference 6)

Rod Block Monitor Upscale Trip Function Two Recirculation Loop Operation Single Recirculation Loop Operation Allowable Val o.65 wd + 55%

o.65 wd + 51%

Wd - percent of recirculation loop drive flow required to produce a rated core flow of 98.0 Mlb/hr.

The setpoint may be lower/higher and will still comply with the RWE analysis because RWE is analyzed unblocked (Reference 22).

Page 51of57

COLR Dresden 2 Revision 16

7. Stability Protection Setpoints Technical Specification Section 3.3.1.3 The OPRM PBDA Trip Settings are provided in Table 7-1.

Table 7-1: OPRM PBDA Trip Settings (Reference 22)

Corresponding Maximum PBDA Trip Amplitude Setpoint (Sp)

Confirmation Count Setpoint (Np) 1.15 16 The PBDA is the only OPRM setting credited in the safety analysis as documented in the licensing basis for the OPRM system (Methodology 2).

The OPRM PBDA trip settings are based, in part, on the cycle specific OLM CPR and the power/flow dependent MCPR limits. Any change to the OLM CPR values and/or the power/flow dependent MCPR limits should be evaluated for potential impact on the OPRM PBDA trip settings.

The OPRM PBDA trip settings are applicable when the OPRM system is declared operable and the associated Technical Specifications are implemented.

Page 52 of 57

COLR Dresden 2 Revision 16

8. Modes of Operation The allowed modes of operation with combinations of EOOS are as described below:

Table 8-1: Modes of Operation (Reference 22)

EOOS Options Thermal Limit Sets Base Base (DLO or SLO)

TBV #8 and any one additional TBV OOS with 2TBVOOS (DLO or SLO)

NSS and NFWT Only TBV #8 and any one additional TBV OOS in a TBVOOS (DLO or SLO) condition other than NSS and NFWT PLUOOS PLUOOS (DLO or SLO)

TBVOOS TBVOOS (DLO or SLO)

TCV Slow Closure TCV Slow Closure (DLO or SLO)

TCV Stuck Closed* **

Base Case (DLO or SLO)

)>

See Table 8-2 for power restrictions PCOOS PLUOOS (DLO or SLO)

PCOOS and PLUOOS PLUOOS (DLO or SLO)

PCOOS and TCV Slow Closure TCV Slow Closure (DLO or SLO)

PCOOS and one TCV Stuck Closed*

PLUOOS (DLO or SLO)

)>

See Table 8-2 for power restrictions PLUOOS and one TCV Stuck Closed*

PLUOOS (DLO or SLO)

)>

See Table 8-2 for power restrictions

  • Also applicable to one TSV Closed and the combination of one TCV and one TSV stuck closed in the same line.
    • EOOS condition has identical thermal limits as the Base Case. Therefore, this condition will use the Base Case thermal limit set.

Page 53 of 57

COLR Dresden 2 Revision 16 Common Notes -Applicable to both Base Case and all EOOS Combinations for DLO/SLO:

1. All modes are allowed for operation at MELLLA, ICF (up to 108% rated core flow but subject to the restrictions in Section 2), and coastdown (subject to restrictions in Table 8-2). Either EOC must be reached or coastdown must begin prior to reaching 16182 MWd/MTU. The licensing analysis remains valid down to a coastdown power level of 70% given all burnup limits are satisfied per Methodology 6. Each OOS Option may be combined with each of the following conditions:
a.

Up to 16 TIP channel traces and 2 common channel traces may be substituted using,the SUBTIP methodology (Reference 12) provided the requirements for utilizing SUBTIP methodology are met as clarified in Reference 18.

b.

Up to 50% of the LPRMs OOS (Reference 12)

c.

An LPRM calibration frequency of up to 2500 EFPH (2000 EFPH + 25%)

(Reference 12)

2.

Nominal FWT results are valid for application within a +10°F/-30°F temperature band around the nominal FWT curve and operating steam dome pressure region bounded by the maximum value of 1020 psia and the minimum pressure curve (Reference 8). The FWTR results are valid for the minimum FWT curve (Reference 22). For operation outside of NFWT, a FWTR of between 30°F and 120°F is supported for Base Case and all EOOS DLO/SLO conditions, except for 2TBVOOS, for cycle operation through EOC subject to the restriction in Reference 4 for feedwater temperature reductions of greater than 100°F. The restriction requires that, for a FWT reduction greater than 100°F, operation needs to be restricted to less than the 100% load line.

3.

All analyses support the fastest Turbine Bypass Valve (assumed to be #1) OOS, with the remaining 8 TBVs meeting the assumed opening profile in Reference 7. The analyses also support Turbine Bypass flow of 3.456 Mlb/hr of vessel rated steam flow, equivalent to one TBV OOS (or partially closed TBVs equivalent to one closed TBV), if the assumed opening profile (Reference 7) for the remaining TBVs is met. If the opening profile is NOT met, or if the TBV system cannot pass an equivalent of 3.456 Mlb/hr of vessel rated steam flow and the 2TBVOOS EOOS option is not being used, utilize the TBVOOS condition (Reference 22).

4. The 2TBVOOS with NSS and NFWT analysis supports Turbine Bypass Valve #8 and any one additional Turbine Bypass Valve OOS, with the remaining 7 TBV meeting the assumed opening profile in Reference 7. If operating with more than one TBV OOS with RFWT, ISS, or TSSS, utilize the TBVOOS condition (Reference 22).
5.

If any TBVs are OOS in the pressure control mode, the maximum steam flow removal capacity for pressure control needs to be evaluated to ensure that at least the equivalent of two TBVs are capable of being opened for pressure control within the limits of the MCFL (Reference 22).

6. A single MSIV may be taken OOS (shut) under all OOS Options, as long as core thermal power is maintained :::: 75% of 2957 MWth (Reference 22).

Page 54 of 57

COLR Dresden 2 Revision 16 Table 8-2: Core Thermal Power Restriction for OOS Conditions (Reference 22)

EOOS Condition Core Thermal Power (% of Rated Power)

One TCV Stuck Closed

  • PCOOS and One TCV Stuck Closed*

.'.':. 75**

PLUOOS and One TCV Stuck Closed*

  • Also applicable to one TSV Closed and the combination of one TCV and one TSV stuck closed in the same line. (Reference 22).
    • Operation above 75% rated power is included as part of the reload analysis. However, operation above 75% power may require raising the MCFL setpoint to increase the available total reactor vessel steam flow capability. Information regarding the steam flow capability necessary to satisfy the reload analysis for operation above 75% power is reported in Reference 22.

Page 55 of 57

COLR Dresden 2 Revision 16

9. Methodology The analytical methods used to determine the core operating limits shall be those previously reviewed and approved by the NRC, specifically those described in the following documents:
1.

GE Topical Report NEDE-24011-P-A, Revision 15, "General Electric Standard Application for Reactor Fuel (GESTAR)," September 2005.

2.

GE Topical Report NED0-32465-A, Revision 0, "Reactor Stability Detect and Suppress Solutions Licensing Basis Methodology for Reload Applications," August 1996.

3.

Westinghouse Report WCAP-15682-P-A, Revision 0, "Westinghouse BWR ECCS Evaluation Model: Supplement 2 to Code Description, Qualification and Application," April 2003.

4.

Westinghouse Report WCAP-16078-P-A, Revision 0, "Westinghouse BWR ECCS Evaluation Model: Supplement 3 to Code Description, Qualification and Application to SVEA-96 Optima2 Fuel," November 2004.

5.

Westinghouse Report WCAP-16081-P-A, Revision 0, "10x10 SVEA Fuel Critical Power Experiments and CPR Correlation: SVEA-96 Optima2," March 2005.

6. Westinghouse Topical Report CENPD-300-P-A, Revision 0, "Reference Safety Report for Boiling Water Reactor Reload Fuel," July 1996.
7.

Westinghouse Topical Report CENPD-390-P-A, Revision 0, "The Advanced PHOENIX and POLCA Codes for Nuclear Design of Boiling Water Reactors," December 2000.

8.

Westinghouse Topical Report WCAP-15836-P-A, Revision 0, "Fuel Rod Design Methods for Boiling Water Reactors - Supplement 1," April 2006.

9.

Westinghouse Topical Report WCAP-15942-P-A, Revision 0, "Fuel Assembly Mechanical Design Methodology for Boiling Water Reactors, Supplement 1 to CENPD-287," March 2006.

10. Westinghouse Report WCAP-16865-P-A, Revision 1, "Westinghouse BWR ECCS Evaluation Model Updates: Supplement 4 to Code Description, Qualification and Application," October 2011.

Page 56 of 57

COLR Dresden 2 Revision 16

10. References
1.

Exelon Generation Company, LLC, Docket No. 50-237, Dresden Nuclear Power Station, Unit 2 Renewed Facility Operating License, License No. DPR-19.

2.

Removed.

3.

Westinghouse Document NF-BEX-13-111-NP, Revision 0, "Dresden Nuclear Power Station Unit 2 Cycle 24 MAPLHGR Report," September 2013.

4.

Exelon Letter, NF-MW:02-0081, "Approval of GE Evaluation of Dresden and Quad Cities Extended Final Feedwater Temperature Reduction," Carlos de la Hoz to Doug Wise and Alex Misak, August 27, 2002.

5.

Exelon Technical Specifications for Dresden 2 and 3, Table 3.1.4-1, "Control Rod Scram Times."

6.

GE ORF C51-00217-01, "Instrument Setpoint Calculation Nuclear Instrumentation, Rod Block Monitor, Commonwealth Edison Company, Dresden 2 & 3," December 15, 1999.

7.

Exelon TOOi OPS Ltr: 15-13, Revision 0, "OPL-W Parameters for Dresden Unit 2 Cycle 25 Transient Analysis," March 9, 2015.

8.

Exelon TOOi ES1500006, Revision O, "Licensing Generic Inputs Report (LGIR)," March 10, 2015.

9.

Westinghouse Document NF-BEX-11-58, Revision 0, "Bundle Design Report for Dresden 2 Cycle 23," April 19, 2011.

10.

Westinghouse Document NF-BEX-11-101-NP, Revision 0, "Dresden Nuclear Power Station Unit 2 Cycle 23 MAPLHGR Report," August 2011.

11.

Westinghouse Document NF-BEX-11-101-NP, Revision 1, "Dresden Nuclear Power Station Unit 2 Cycle 23 MAPLHGR Report," September 2015.

12.

Exelon Engineering Evaluation, EC 357691-000, "EVALUATION OF APPROPRIATE UNCERTAINTIES FOR USE BY WESTINGHOUSE IN SAFETY LIMIT MCPR ANALYSES,"

November 28, 2005.

13.

Westinghouse Document NF-BEX-15-98, Revision 0, "Dresden Nuclear Power Station Unit 2 Cycle 25 Reload Engineering Report," September 2015.

14.

Westinghouse Document NF-BEX-15-88, Revision 0, "Safety Limit MCPR for Dresden Unit 2 Cycle 25," June 2, 2015.

15.

Westinghouse Document NF-BEX-13-66, Revision 0, "Bundle Design Report for Dresden 2 Cycle 24," May 3, 2013.

16.

Westinghouse Document NF-BEX-15-101-NP, Revision 0, "Dresden Nuclear Power Station Unit 2 Cycle 25 MAPLHGR Report," September 2015.

17.

Westinghouse Document NF-BEX-15-72, Revision 0, "Bundle Design Report for Dresden 2 Cycle 25," April 17, 2015.

18.

FANP Letter, NJC:04:031/FAB04-496, "Startup with TIP Equipment Out of Service," April 20, 2004. (Exelon EC 348897-000)

19.

Westinghouse Document BTD 09-0311, Revision 1, "Westinghouse CMS - Operation guidelines for Dresden and Quad Cities plants," July 20, 2009.

20.

Westinghouse Letter NF-BEX-15-12, "Linear Heat Generation Rate Limits for Fresh and Once-Burned Fuel Loaded in Dresden Unit 2 Cycle 24," January 14, 2015.

21.

Westinghouse Letter NF-BEX-15-157, "Linear Heat Generation Rate Limits for Fresh Fuel Loaded in Dresden Unit 2 Cycle 25," October 28, 28, 2015.

22.

Westinghouse Document NF-BEX-15-105, Revision 1, "Dresden Nuclear Power Station Unit 2 Cycle 25 Reload Licensing Report," August 2016.

Page 57 of 57