1 NRR-PMDAPEm Resource From:
Harrison Albon <awharrison@STPEGS.COM>
Sent:
Wednesday, September 14, 2016 10:04 AM To:
Regner, Lisa; Klos, John
Subject:
[External_Sender] DRAFT Response to SSIB Follow up to RAI 37 Attachments:
RAI-37 Supplement SBLOCA Thickness.pdf Lisa, John, Please see attached supplemental response for Steve Smith and SSIB for todays public call.
Wayne STP Licensing (979) 292-6413
Hearing Identifier:
NRR_PMDA Email Number:
3060 Mail Envelope Properties (fda824daef404514a71e7bbaef91f6e8)
Subject:
[External_Sender] DRAFT Response to SSIB Follow up to RAI 37 Sent Date:
9/14/2016 10:03:34 AM Received Date:
9/14/2016 10:04:01 AM From:
Harrison Albon Created By:
awharrison@STPEGS.COM Recipients:
"Regner, Lisa" <Lisa.Regner@nrc.gov>
Tracking Status: None "Klos, John" <John.Klos@nrc.gov>
Tracking Status: None Post Office:
CMBXEXCH03.CORP.STPEGS.NET Files Size Date & Time MESSAGE 152 9/14/2016 10:04:01 AM RAI-37 Supplement SBLOCA Thickness.pdf 1515148 Options Priority:
Standard Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
Recipients Received:
DRAFT Supplement to Follow up SSIB RAI 37 This write-up is provided to supplement the Follow-up to RAI-37 response with additional insights about transported fiber and maximum expected bed thickness. The sole intent of the original response to RAI-37 provided in the August 2015 submittal was to say that NPSH margin and head loss are bounded by LBLOCA analysis; meaning LBLOCAs represent the worst cases for STP resulting in smaller calculated NPSH margin and higher head losses. The table below (Table 1) provides the transported fibrous debris amounts for all small breaks (<2) in containment for two train scenarios as well as the associated transported volumes and max theoretical bed thicknesses. All two train SBLOCA cases
(<2) result in a max debris bed thickness smaller than 1/16; note that pipe sizes with an inner diameter smaller than 2-inches were analyzed with a DEGB spherical ZOI, while those pipes with an inner diameter larger than 2-inches were analyzed with a hemispherical break in the direction of max fibrous debris generation. The max transported SBLOCA debris volumes and bed thickness support the assertion that head loss for these scenarios is very small and that NPSH margin and calculated head loss are bounded by evaluation of LBLOCA scenarios. This assertion is also supported for one train cases.
Evaluation of one train scenarios yields ~1/16 debris beds for all cases (See Table 2). Note that the last two columns of Table 1 and Table 2 are different from each other because of differing number operable trains for the scenarios; Table 1 represent 2-trains in operation with debris split between two strainers and Table 2 represents 1-train in operation with debris all accumulating on a single strainer.
Table 1: SBLOCA Max Transported Fiber Mass, Volume, and Expected Bed Thickness for Two Train Cases Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 2-Train (ft^3 per strainer)
Bed Thickness 2-Train (in) 0.75-CV-1122-BB1-1 0.614 0.05 28.50 28.55 5.95 0.036 0.75-CV-1122-BB1-2 0.614 0.05 28.50 28.55 5.95 0.036 0.75-CV-1124-BB1-1 0.614 0.00 28.50 28.50 5.94 0.036 0.75-CV-1124-BB1-2 0.614 0.00 28.50 28.50 5.94 0.036 0.75-CV-1126-BB1-1 0.614 0.00 28.50 28.50 5.94 0.036 0.75-CV-1126-BB1-2 0.614 0.18 28.50 28.68 5.98 0.037 0.75-CV-1128-BB1-1 0.614 0.00 28.50 28.50 5.94 0.036 0.75-CV-1128-BB1-2 0.614 0.00 28.50 28.50 5.94 0.036 0.75-RC-1001-BB1-1 0.614 0.24 28.50 28.74 5.99 0.037 0.75-RC-1002-BB2-1 0.614 0.29 28.50 28.79 6.00 0.037 0.75-RC-1112-BB1-1 0.614 0.29 28.50 28.79 6.00 0.037 0.75-RC-1114-BB1-1 0.614 0.44 28.50 28.94 6.03 0.037 0.75-RC-1125-BB1-1 0.614 0.28 28.50 28.78 6.00 0.037 0.75-RC-1125-BB1-2 0.614 0.37 28.50 28.87 6.02 0.037
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 2-Train (ft^3 per strainer)
Bed Thickness 2-Train (in) 0.75-RC-1126-BB1-1 0.614 0.35 28.50 28.85 6.01 0.037 0.75-RC-1212-BB1-1 0.614 0.34 28.50 28.84 6.01 0.037 0.75-RC-1214-BB1-1 0.614 0.38 28.50 28.88 6.02 0.037 0.75-RC-1221-BB1-1 0.614 0.29 28.50 28.79 6.00 0.037 0.75-RC-1221-BB1-2 0.614 0.29 28.50 28.79 6.00 0.037 0.75-RC-1312-BB1-1 0.614 0.33 28.50 28.83 6.01 0.037 0.75-RC-1324-BB1-1 0.614 0.43 28.50 28.93 6.03 0.037 0.75-RC-1423-BB1-1 0.614 0.53 28.50 29.03 6.05 0.037 0.75-SI-1130-BB2-1 0.614 0.25 28.50 28.75 5.99 0.037 0.75-SI-1132-BB1-1 0.614 0.15 28.50 28.65 5.97 0.036 0.75-SI-1218-BB1-1 0.614 0.18 28.50 28.68 5.97 0.037 0.75-SI-1223-BB2-1 0.614 0.24 28.50 28.74 5.99 0.037 0.75-SI-1315-BB1-1 0.614 0.38 28.50 28.88 6.02 0.037 0.75-SI-1323-BB1-1 0.614 0.17 28.50 28.67 5.97 0.037 0.75-SI-1327-BB1-1 0.614 0.21 28.50 28.71 5.98 0.037 0.75-SI-1327-BB1-2 0.614 0.20 28.50 28.70 5.98 0.037 0.75-SI-1327-BB1-3 0.614 0.19 28.50 28.69 5.98 0.037 0.75-SI-1328-BB2-1 0.614 0.24 28.50 28.74 5.99 0.037 1-RC-1003-BB1-1 0.815 0.78 28.50 29.28 6.10 0.037 1-RC-1123-BB1-1 0.815 0.36 28.50 28.86 6.01 0.037 1-RC-1422-BB1-1 0.815 0.66 28.50 29.16 6.08 0.037 1.5-RC-1412-NSS-1 1.338 1.86 28.50 30.36 6.32 0.039 2(1.5)-CV-1122-BB1-1 1.338 0.08 28.50 28.58 5.95 0.036 2(1.5)-CV-1122-BB1-2 1.338 0.25 28.50 28.75 5.99 0.037
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 2-Train (ft^3 per strainer)
Bed Thickness 2-Train (in) 2(1.5)-CV-1124-BB1-1 1.338 0.07 28.50 28.57 5.95 0.036 2(1.5)-CV-1124-BB1-2 1.338 0.37 28.50 28.87 6.01 0.037 2(1.5)-CV-1126-BB1-1 1.338 0.58 28.50 29.08 6.06 0.037 2(1.5)-CV-1126-BB1-2 1.338 0.57 28.50 29.07 6.06 0.037 2(1.5)-CV-1128-BB1-1 1.338 0.25 28.50 28.75 5.99 0.037 2(1.5)-CV-1128-BB1-2 1.338 0.52 28.50 29.02 6.05 0.037 2-CV-1121-BB1-1 1.689 0.26 28.50 28.76 5.99 0.037 2-CV-1121-BB1-2 1.689 0.53 28.50 29.03 6.05 0.037 2-CV-1121-BB1-3 1.689 0.77 28.50 29.27 6.10 0.037 2-CV-1122-BB1-1 1.689 0.92 28.50 29.42 6.13 0.037 2-CV-1122-BB1-2 1.689 0.85 28.50 29.35 6.12 0.037 2-CV-1122-BB1-3 1.689 0.78 28.50 29.28 6.10 0.037 2-CV-1122-BB1-4 1.689 0.75 28.50 29.25 6.09 0.037 2-CV-1122-BB1-5 1.689 0.82 28.50 29.32 6.11 0.037 2-CV-1122-BB1-6 1.689 0.45 28.50 28.95 6.03 0.037 2-CV-1124-BB1-1 1.689 0.76 28.50 29.26 6.10 0.037 2-CV-1124-BB1-2 1.689 0.79 28.50 29.29 6.10 0.037 2-CV-1124-BB1-3 1.689 0.79 28.50 29.29 6.10 0.037 2-CV-1124-BB1-4 1.689 0.91 28.50 29.41 6.13 0.037 2-CV-1124-BB1-5 1.689 1.00 28.50 29.50 6.15 0.038 2-CV-1124-BB1-6 1.689 0.95 28.50 29.45 6.14 0.038 2-CV-1124-BB1-7 1.689 0.79 28.50 29.29 6.10 0.037 2-CV-1124-BB1-8 1.689 0.78 28.50 29.28 6.10 0.037 2-CV-1124-BB1-9 1.689 0.84 28.50 29.34 6.11 0.037
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 2-Train (ft^3 per strainer)
Bed Thickness 2-Train (in) 2-CV-1124-BB1-10 1.689 0.88 28.50 29.38 6.12 0.037 2-CV-1124-BB1-11 1.689 0.84 28.50 29.34 6.11 0.037 2-CV-1124-BB1-12 1.689 0.36 28.50 28.86 6.01 0.037 2-CV-1124-BB1-13 1.689 0.39 28.50 28.89 6.02 0.037 2-CV-1126-BB1-1 1.689 0.24 28.50 28.74 5.99 0.037 2-CV-1126-BB1-2 1.689 0.29 28.50 28.79 6.00 0.037 2-CV-1126-BB1-3 1.689 0.34 28.50 28.84 6.01 0.037 2-CV-1126-BB1-4 1.689 0.38 28.50 28.88 6.02 0.037 2-CV-1126-BB1-5 1.689 0.37 28.50 28.87 6.01 0.037 2-CV-1126-BB1-6 1.689 0.40 28.50 28.90 6.02 0.037 2-CV-1126-BB1-7 1.689 0.50 28.50 29.00 6.04 0.037 2-CV-1126-BB1-8 1.689 1.49 28.50 29.99 6.25 0.038 2-CV-1126-BB1-9 1.689 1.60 28.50 30.10 6.27 0.038 2-CV-1126-BB1-10 1.689 0.93 28.50 29.43 6.13 0.037 2-CV-1126-BB1-11 1.689 0.86 28.50 29.36 6.12 0.037 2-CV-1128-BB1-1 1.689 0.01 28.50 28.51 5.94 0.036 2-CV-1128-BB1-2 1.689 0.17 28.50 28.67 5.97 0.037 2-CV-1128-BB1-3 1.689 0.27 28.50 28.77 5.99 0.037 2-CV-1128-BB1-3A 1.689 0.32 28.50 28.82 6.01 0.037 2-CV-1128-BB1-3B 1.689 0.37 28.50 28.87 6.01 0.037 2-CV-1128-BB1-4 1.689 0.36 28.50 28.86 6.01 0.037 2-CV-1128-BB1-5 1.689 0.37 28.50 28.87 6.01 0.037 2-CV-1128-BB1-6 1.689 0.35 28.50 28.85 6.01 0.037 2-CV-1128-BB1-7 1.689 0.46 28.50 28.96 6.03 0.037
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 2-Train (ft^3 per strainer)
Bed Thickness 2-Train (in) 2-CV-1141-BB1-1 1.689 0.56 28.50 29.06 6.05 0.037 2-CV-1141-BB1-2 1.689 0.36 28.50 28.86 6.01 0.037 2-RC-1003-BB1-1 1.689 0.77 28.50 29.27 6.10 0.037 2-RC-1003-BB1-2 1.689 1.22 28.50 29.72 6.19 0.038 2-RC-1120-BB1-1 1.689 1.43 28.50 29.93 6.24 0.038 2-RC-1120-BB1-2 1.689 1.12 28.50 29.62 6.17 0.038 2-RC-1121-BB1-1 1.689 1.89 28.50 30.39 6.33 0.039 2-RC-1121-BB1-2 1.689 0.61 28.50 29.11 6.07 0.037 2-RC-1121-BB1-3 1.689 0.64 28.50 29.14 6.07 0.037 2-RC-1121-BB1-3A 1.689 0.62 28.50 29.12 6.07 0.037 2-RC-1121-BB1-3B 1.689 0.53 28.50 29.03 6.05 0.037 2-RC-1121-BB1-4 1.689 0.46 28.50 28.96 6.03 0.037 2-RC-1219-BB1-1 1.689 1.38 28.50 29.88 6.23 0.038 2-RC-1219-BB1-2 1.689 1.24 28.50 29.74 6.20 0.038 2-RC-1220-BB1-1 1.689 1.78 28.50 30.28 6.31 0.039 2-RC-1220-BB1-2 1.689 0.55 28.50 29.05 6.05 0.037 2-RC-1220-BB1-3 1.689 0.51 28.50 29.01 6.04 0.037 2-RC-1220-BB1-4 1.689 0.42 28.50 28.92 6.03 0.037 2-RC-1319-BB1-1 1.689 1.58 28.50 30.08 6.27 0.038 2-RC-1319-BB1-2 1.689 1.14 28.50 29.64 6.17 0.038 2-RC-1321-BB1-1 1.689 1.26 28.50 29.76 6.20 0.038 2-RC-1321-BB1-4 1.689 1.19 28.50 29.69 6.19 0.038 2-RC-1321-BB1-5 1.689 1.32 28.50 29.82 6.21 0.038 2-RC-1321-BB1-6 1.689 1.28 28.50 29.78 6.20 0.038
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 2-Train (ft^3 per strainer)
Bed Thickness 2-Train (in) 2-RC-1417-BB1-1 1.689 1.37 28.50 29.87 6.22 0.038 2-RC-1417-BB1-2 1.689 1.30 28.50 29.80 6.21 0.038 2-RC-1418-BB1-1 1.689 1.79 28.50 30.29 6.31 0.039 2-RC-1418-BB1-2 1.689 1.21 28.50 29.71 6.19 0.038 2-RC-1418-BB1-3 1.689 1.13 28.50 29.63 6.17 0.038 2-RC-1418-BB1-4 1.689 1.07 28.50 29.57 6.16 0.038 2-RC-1418-BB1-5 1.689 0.91 28.50 29.41 6.13 0.037 2-RC-1418-BB1-6 1.689 0.73 28.50 29.23 6.09 0.037 2-RC-1419-BB1-1 1.689 1.06 28.50 29.56 6.16 0.038 2-RC-1419-BB1-2 1.689 0.83 28.50 29.33 6.11 0.037 2-RC-1419-BB1-3 1.689 0.86 28.50 29.36 6.12 0.037 2-RC-1419-BB1-4 1.689 0.57 28.50 29.07 6.06 0.037 2.5-RC-1003-BB1-1 2.000 1.10 28.50 29.60 6.17 0.038 2.5-RC-1003-BB1-2 2.000 1.03 28.50 29.53 6.15 0.038 2.5-RC-1003-BB1-3 2.000 1.60 28.50 30.10 6.27 0.038 2.5-RC-1003-BB1-4 2.000 1.64 28.50 30.14 6.28 0.038 2.5-RC-1003-BB1-5 2.000 1.50 28.50 30.00 6.25 0.038 2.5-RC-1003-BB1-6 2.000 1.45 28.50 29.95 6.24 0.038 3-RC-1003-BB1-1 2.000 1.56 28.50 30.06 6.26 0.038 3-RC-1003-BB1-2 2.000 1.29 28.50 29.79 6.21 0.038 3-RC-1015-NSS-1 2.000 1.19 28.50 29.69 6.19 0.038 3-RC-1015-NSS-2 2.000 1.44 28.50 29.94 6.24 0.038 3-RC-1015-NSS-3 2.000 0.95 28.50 29.45 6.14 0.038 3-RC-1015-NSS-4 2.000 0.37 28.50 28.87 6.01 0.037
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 2-Train (ft^3 per strainer)
Bed Thickness 2-Train (in) 3-RC-1015-NSS-5 2.000 0.08 28.50 28.58 5.95 0.036 3-RC-1015-NSS-6 2.000 0.00 28.50 28.50 5.94 0.036 3-RC-1015-NSS-7 2.000 0.00 28.50 28.50 5.94 0.036 3-RC-1015-NSS-8 2.000 0.00 28.50 28.50 5.94 0.036 3-RC-1015-NSS-9 2.000 1.31 28.50 29.81 6.21 0.038 3-RC-1015-NSS-10 2.000 1.60 28.50 30.10 6.27 0.038 3-RC-1015-NSS-11 2.000 1.12 28.50 29.62 6.17 0.038 3-RC-1015-NSS-12 2.000 0.49 28.50 28.99 6.04 0.037 3-RC-1015-NSS-13 2.000 0.10 28.50 28.60 5.96 0.036 3-RC-1015-NSS-14 2.000 0.00 28.50 28.50 5.94 0.036 3-RC-1015-NSS-15 2.000 0.00 28.50 28.50 5.94 0.036 3-RC-1015-NSS-16 2.000 0.06 28.50 28.56 5.95 0.036 3-RC-1106-BB1-25 2.000 1.08 28.50 29.58 6.16 0.038 3-RC-1206-BB1-28 2.000 1.14 28.50 29.64 6.18 0.038 3-RC-1306-BB1-28 2.000 1.08 28.50 29.58 6.16 0.038 3-RC-1406-BB1-25 2.000 1.14 28.50 29.64 6.17 0.038 4-CV-1001-BB1-1 2.000 0.77 28.50 29.27 6.10 0.037 4-CV-1001-BB1-2 2.000 0.61 28.50 29.11 6.07 0.037 4-CV-1118-BB1-1 2.000 0.45 28.50 28.95 6.03 0.037 4-CV-1118-BB1-2 2.000 0.74 28.50 29.24 6.09 0.037 4-CV-1120-BB1-1 2.000 0.87 28.50 29.37 6.12 0.037 4-CV-1120-BB1-2 2.000 0.60 28.50 29.10 6.06 0.037 4-RC-1000-BB1-1 2.000 1.65 28.50 30.15 6.28 0.038 4-RC-1000-BB1-2 2.000 1.80 28.50 30.30 6.31 0.039
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 2-Train (ft^3 per strainer)
Bed Thickness 2-Train (in) 4-RC-1000-BB1-3 2.000 1.90 28.50 30.40 6.33 0.039 4-RC-1000-BB1-4 2.000 0.93 28.50 29.43 6.13 0.037 4-RC-1000-BB1-5 2.000 0.93 28.50 29.43 6.13 0.037 4-RC-1000-BB1-6 2.000 1.00 28.50 29.50 6.14 0.038 4-RC-1000-BB1-7 2.000 0.98 28.50 29.48 6.14 0.038 4-RC-1000-BB1-8 2.000 0.82 28.50 29.32 6.11 0.037 4-RC-1003-BB1-1 2.000 1.23 28.50 29.73 6.19 0.038 4-RC-1003-BB1-2 2.000 1.14 28.50 29.64 6.18 0.038 4-RC-1003-BB1-3 2.000 1.29 28.50 29.79 6.21 0.038 4-RC-1003-BB1-4 2.000 1.11 28.50 29.61 6.17 0.038 4-RC-1123-BB1-1 2.000 1.41 28.50 29.91 6.23 0.038 4-RC-1123-BB1-2 2.000 0.63 28.50 29.13 6.07 0.037 4-RC-1123-BB1-3 2.000 0.74 28.50 29.24 6.09 0.037 4-RC-1123-BB1-4 2.000 0.76 28.50 29.26 6.10 0.037 4-RC-1123-BB1-5 2.000 0.66 28.50 29.16 6.07 0.037 4-RC-1123-BB1-6 2.000 0.66 28.50 29.16 6.07 0.037 4-RC-1123-BB1-7 2.000 0.63 28.50 29.13 6.07 0.037 4-RC-1123-BB1-8 2.000 0.66 28.50 29.16 6.08 0.037 4-RC-1123-BB1-9 2.000 0.44 28.50 28.94 6.03 0.037 4-RC-1123-BB1-10 2.000 0.69 28.50 29.19 6.08 0.037 4-RC-1123-BB1-11 2.000 0.71 28.50 29.21 6.09 0.037 4-RC-1123-BB1-12 2.000 0.79 28.50 29.29 6.10 0.037 4-RC-1123-BB1-13 2.000 0.78 28.50 29.28 6.10 0.037 4-RC-1123-BB1-14 2.000 0.63 28.50 29.13 6.07 0.037
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 2-Train (ft^3 per strainer)
Bed Thickness 2-Train (in) 4-RC-1123-BB1-15 2.000 0.57 28.50 29.07 6.06 0.037 4-RC-1123-BB1-16 2.000 0.84 28.50 29.34 6.11 0.037 4-RC-1123-BB1-17 2.000 0.83 28.50 29.33 6.11 0.037 4-RC-1123-BB1-18 2.000 1.51 28.50 30.01 6.25 0.038 4-RC-1123-BB1-19 2.000 1.55 28.50 30.05 6.26 0.038 4-RC-1123-BB1-20 2.000 1.47 28.50 29.97 6.24 0.038 4-RC-1126-BB1-1 2.000 0.91 28.50 29.41 6.13 0.037 4-RC-1126-BB1-2 2.000 0.87 28.50 29.37 6.12 0.037 4-RC-1126-BB1-3 2.000 1.22 28.50 29.72 6.19 0.038 4-RC-1126-BB1-4 2.000 1.23 28.50 29.73 6.19 0.038 4-RC-1126-BB1-5 2.000 1.08 28.50 29.58 6.16 0.038 4-RC-1126-BB1-6 2.000 1.47 28.50 29.97 6.24 0.038 4-RC-1320-BB1-1 2.000 1.65 28.50 30.15 6.28 0.038 4-RC-1320-BB1-2 2.000 1.51 28.50 30.01 6.25 0.038 4-RC-1320-BB1-3 2.000 1.84 28.50 30.34 6.32 0.039 4-RC-1320-BB1-4 2.000 1.17 28.50 29.67 6.18 0.038 4-RC-1320-BB1-5 2.000 0.99 28.50 29.49 6.14 0.038 4-RC-1320-BB1-6 2.000 1.00 28.50 29.50 6.15 0.038 4-RC-1320-BB1-7 2.000 1.11 28.50 29.61 6.17 0.038 4-RC-1320-BB1-8 2.000 1.15 28.50 29.65 6.18 0.038 4-RC-1320-BB1-9 2.000 1.17 28.50 29.67 6.18 0.038 4-RC-1320-BB1-10 2.000 1.21 28.50 29.71 6.19 0.038 4-RC-1320-BB1-11 2.000 1.48 28.50 29.98 6.25 0.038 4-RC-1320-BB1-12 2.000 1.16 28.50 29.66 6.18 0.038
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 2-Train (ft^3 per strainer)
Bed Thickness 2-Train (in) 4-RC-1323-BB1-1 2.000 0.88 28.50 29.38 6.12 0.037 4-RC-1323-BB1-2 2.000 0.66 28.50 29.16 6.08 0.037 4-RC-1323-BB1-3 2.000 0.80 28.50 29.30 6.10 0.037 4-RC-1323-BB1-4 2.000 1.19 28.50 29.69 6.18 0.038 4-RC-1420-BB1-1 2.000 1.65 28.50 30.15 6.28 0.038 4-RC-1422-BB1-1 2.000 1.76 28.50 30.26 6.30 0.039 4-RC-1422-BB1-2 2.000 1.55 28.50 30.05 6.26 0.038 4-RC-1422-BB1-3 2.000 1.70 28.50 30.20 6.29 0.038 4-RC-1422-BB1-4 2.000 1.74 28.50 30.24 6.30 0.039 4-RC-1422-BB1-5 2.000 1.39 28.50 29.89 6.23 0.038 4-RC-1422-BB1-6 2.000 0.99 28.50 29.49 6.14 0.038 4-RC-1422-BB1-7 2.000 1.01 28.50 29.51 6.15 0.038 4-RC-1422-BB1-8 2.000 1.01 28.50 29.51 6.15 0.038 4-RC-1422-BB1-9 2.000 0.99 28.50 29.49 6.14 0.038 4-RC-1422-BB1-10 2.000 0.65 28.50 29.15 6.07 0.037 4-RC-1422-BB1-11 2.000 0.63 28.50 29.13 6.07 0.037 4-RC-1422-BB1-12 2.000 0.43 28.50 28.93 6.03 0.037 4-RC-1422-BB1-13 2.000 0.85 28.50 29.35 6.11 0.037 4-RC-1422-BB1-14 2.000 0.79 28.50 29.29 6.10 0.037 4-RC-1422-BB1-15 2.000 0.61 28.50 29.11 6.06 0.037 4-RC-1422-BB1-16 2.000 0.63 28.50 29.13 6.07 0.037 4-RC-1422-BB1-17 2.000 0.75 28.50 29.25 6.09 0.037 4-RC-1422-BB1-18 2.000 0.67 28.50 29.17 6.08 0.037 4-RC-1422-BB1-19 2.000 0.52 28.50 29.02 6.05 0.037
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 2-Train (ft^3 per strainer)
Bed Thickness 2-Train (in) 4-RC-1422-BB1-20 2.000 0.54 28.50 29.04 6.05 0.037 4-RC-1422-BB1-21 2.000 1.62 28.50 30.12 6.28 0.038 4-RC-1422-BB1-22 2.000 1.73 28.50 30.23 6.30 0.038 4-RC-1422-BB1-23 2.000 1.36 28.50 29.86 6.22 0.038 6-RC-1003-BB1-1 2.000 1.00 28.50 29.50 6.15 0.038 6-RC-1003-BB1-2 2.000 0.86 28.50 29.36 6.12 0.037 6-RC-1003-BB1-3 2.000 0.93 28.50 29.43 6.13 0.037 6-RC-1003-BB1-4 2.000 1.15 28.50 29.65 6.18 0.038 6-RC-1003-BB1-5 2.000 1.26 28.50 29.76 6.20 0.038 6-RC-1003-BB1-6 2.000 1.43 28.50 29.93 6.24 0.038 6-RC-1003-BB1-7 2.000 1.32 28.50 29.82 6.21 0.038 6-RC-1003-BB1-8 2.000 1.80 28.50 30.30 6.31 0.039 6-RC-1003-BB1-9 2.000 2.21 28.50 30.71 6.40 0.039 6-RC-1003-BB1-9A 2.000 1.80 28.50 30.30 6.31 0.039 6-RC-1003-BB1-9B 2.000 1.75 28.50 30.25 6.30 0.039 6-RC-1003-BB1-10 2.000 1.15 28.50 29.65 6.18 0.038 6-RC-1003-BB1-11 2.000 1.00 28.50 29.50 6.15 0.038 6-RC-1003-BB1-11A 2.000 1.28 28.50 29.78 6.20 0.038 6-RC-1003-BB1-11B 2.000 1.41 28.50 29.91 6.23 0.038 6-RC-1003-BB1-12 2.000 1.39 28.50 29.89 6.23 0.038 6-RC-1003-BB1-13 2.000 1.92 28.50 30.42 6.34 0.039 6-RC-1003-BB1-13A 2.000 2.24 28.50 30.74 6.40 0.039 6-RC-1003-BB1-14 2.000 2.53 28.50 31.03 6.46 0.040 6-RC-1003-BB1-PRZ-1-N2-SE 2.000 2.52 28.50 31.02 6.46 0.040
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 2-Train (ft^3 per strainer)
Bed Thickness 2-Train (in) 6-RC-1004-NSS-1 2.000 3.20 28.50 31.70 6.60 0.040 6-RC-1004-NSS-2 2.000 3.47 28.50 31.97 6.66 0.041 6-RC-1004-NSS-3 2.000 2.64 28.50 31.14 6.49 0.040 6-RC-1004-NSS-4 2.000 2.71 28.50 31.21 6.50 0.040 6-RC-1004-NSS-5 2.000 3.02 28.50 31.52 6.57 0.040 6-RC-1004-NSS-6 2.000 2.86 28.50 31.36 6.53 0.040 6-RC-1004-NSS-7 2.000 2.25 28.50 30.75 6.41 0.039 6-RC-1004-NSS-PRZ-1-N3-SE 2.000 3.11 28.50 31.61 6.58 0.040 6-RC-1009-NSS-1 2.000 2.93 28.50 31.43 6.55 0.040 6-RC-1009-NSS-2 2.000 3.36 28.50 31.86 6.64 0.041 6-RC-1009-NSS-3 2.000 2.09 28.50 30.59 6.37 0.039 6-RC-1009-NSS-4 2.000 2.36 28.50 30.86 6.43 0.039 6-RC-1009-NSS-5 2.000 2.97 28.50 31.47 6.56 0.040 6-RC-1009-NSS-6 2.000 3.42 28.50 31.92 6.65 0.041 6-RC-1009-NSS-7 2.000 3.08 28.50 31.58 6.58 0.040 6-RC-1009-NSS-8 2.000 2.83 28.50 31.33 6.53 0.040 6-RC-1009-NSS-9 2.000 2.01 28.50 30.51 6.36 0.039 6-RC-1009-NSS-PRZ-1-N4C-SE 2.000 2.95 28.50 31.45 6.55 0.040 6-RC-1012-NSS-1 2.000 2.99 28.50 31.49 6.56 0.040 6-RC-1012-NSS-2 2.000 3.35 28.50 31.85 6.64 0.041 6-RC-1012-NSS-3 2.000 3.08 28.50 31.58 6.58 0.040 6-RC-1012-NSS-4 2.000 2.79 28.50 31.29 6.52 0.040 6-RC-1012-NSS-5 2.000 3.56 28.50 32.06 6.68 0.041 6-RC-1012-NSS-6 2.000 3.59 28.50 32.09 6.68 0.041
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 2-Train (ft^3 per strainer)
Bed Thickness 2-Train (in) 6-RC-1012-NSS-7 2.000 3.36 28.50 31.86 6.64 0.041 6-RC-1012-NSS-8 2.000 3.53 28.50 32.03 6.67 0.041 6-RC-1012-NSS-9 2.000 4.15 28.50 32.65 6.80 0.042 6-RC-1012-NSS-10 2.000 3.69 28.50 32.19 6.71 0.041 6-RC-1012-NSS-11 2.000 3.46 28.50 31.96 6.66 0.041 6-RC-1012-NSS-PRZ-1-N4B-SE 2.000 2.99 28.50 31.49 6.56 0.040 6-RC-1015-NSS-1 2.000 3.49 28.50 31.99 6.66 0.041 6-RC-1015-NSS-2 2.000 3.71 28.50 32.21 6.71 0.041 6-RC-1015-NSS-3 2.000 3.90 28.50 32.40 6.75 0.041 6-RC-1015-NSS-4 2.000 3.98 28.50 32.48 6.77 0.041 6-RC-1015-NSS-5 2.000 3.91 28.50 32.41 6.75 0.041 6-RC-1015-NSS-6 2.000 3.56 28.50 32.06 6.68 0.041 6-RC-1015-NSS-7 2.000 3.20 28.50 31.70 6.60 0.040 6-RC-1015-NSS-8 2.000 3.19 28.50 31.69 6.60 0.040 6-RC-1015-NSS-9 2.000 2.78 28.50 31.28 6.52 0.040 6-RC-1015-NSS-10 2.000 2.34 28.50 30.84 6.42 0.039 6-RC-1015-NSS-11 2.000 1.45 28.50 29.95 6.24 0.038 6-RC-1015-NSS-12 2.000 1.49 28.50 29.99 6.25 0.038 6-RC-1015-NSS-13 2.000 1.43 28.50 29.93 6.23 0.038 6-RC-1015-NSS-14 2.000 1.57 28.50 30.07 6.26 0.038 6-RC-1015-NSS-15 2.000 1.50 28.50 30.00 6.25 0.038 6-SI-1108-BB1-1 2.000 0.32 28.50 28.82 6.00 0.037 6-SI-1108-BB1-2 2.000 0.36 28.50 28.86 6.01 0.037 6-SI-1108-BB1-3 2.000 0.38 28.50 28.88 6.02 0.037 6-SI-1108-BB1-4 2.000 1.13 28.50 29.63 6.17 0.038 6-SI-1111-BB1-1 2.000 0.66 28.50 29.16 6.07 0.037 6-SI-1111-BB1-2 2.000 0.74 28.50 29.24 6.09 0.037
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 2-Train (ft^3 per strainer)
Bed Thickness 2-Train (in) 6-SI-1208-BB1-1 2.000 0.31 28.50 28.81 6.00 0.037 6-SI-1208-BB1-2 2.000 0.34 28.50 28.84 6.01 0.037 6-SI-1208-BB1-3 2.000 0.38 28.50 28.88 6.02 0.037 6-SI-1208-BB1-4 2.000 0.52 28.50 29.02 6.05 0.037 6-SI-1211-BB1-1 2.000 0.46 28.50 28.96 6.03 0.037 6-SI-1211-BB1-2 2.000 0.56 28.50 29.06 6.05 0.037 6-SI-1308-BB1-1 2.000 0.68 28.50 29.18 6.08 0.037 6-SI-1308-BB1-2 2.000 0.68 28.50 29.18 6.08 0.037 6-SI-1308-BB1-3 2.000 0.64 28.50 29.14 6.07 0.037 6-SI-1308-BB1-4 2.000 0.79 28.50 29.29 6.10 0.037 6-SI-1327-BB1-1 2.000 0.60 28.50 29.10 6.06 0.037 6-SI-1327-BB1-2 2.000 0.93 28.50 29.43 6.13 0.037 6-SI-1327-BB1-3 2.000 1.00 28.50 29.50 6.15 0.038 6-SI-1327-BB1-4 2.000 0.81 28.50 29.31 6.11 0.037 6-SI-1327-BB1-5 2.000 1.05 28.50 29.55 6.16 0.038 6-SI-1327-BB1-6 2.000 1.04 28.50 29.54 6.15 0.038 6-SI-1327-BB1-7 2.000 1.26 28.50 29.76 6.20 0.038 8-RC-1114-BB1-1 2.000 0.99 28.50 29.49 6.14 0.038 8-RC-1114-BB1-2 2.000 1.19 28.50 29.69 6.19 0.038 8-RC-1114-BB1-3 2.000 1.32 28.50 29.82 6.21 0.038 8-RC-1114-BB1-4 2.000 1.38 28.50 29.88 6.22 0.038 8-RC-1114-BB1-5 2.000 1.66 28.50 30.16 6.28 0.038 8-RC-1114-BB1-6 2.000 2.07 28.50 30.57 6.37 0.039 8-RC-1214-BB1-1 2.000 1.21 28.50 29.71 6.19 0.038 8-RC-1214-BB1-2 2.000 1.24 28.50 29.74 6.20 0.038 8-RC-1214-BB1-3 2.000 1.33 28.50 29.83 6.21 0.038 8-RC-1214-BB1-4 2.000 1.25 28.50 29.75 6.20 0.038 8-RC-1214-BB1-5 2.000 1.68 28.50 30.18 6.29 0.038 8-RC-1214-BB1-6 2.000 2.11 28.50 30.61 6.38 0.039 8-RC-1324-BB1-1 2.000 1.20 28.50 29.70 6.19 0.038 8-RC-1324-BB1-2 2.000 1.35 28.50 29.85 6.22 0.038 8-RC-1324-BB1-3 2.000 1.47 28.50 29.97 6.24 0.038
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 2-Train (ft^3 per strainer)
Bed Thickness 2-Train (in) 8-RC-1324-BB1-4 2.000 1.41 28.50 29.91 6.23 0.038 8-RC-1324-BB1-5 2.000 1.63 28.50 30.13 6.28 0.038 8-RC-1324-BB1-6 2.000 1.96 28.50 30.46 6.35 0.039 8-RH-1108-BB1-1 2.000 0.31 28.50 28.81 6.00 0.037 8-RH-1108-BB1-2 2.000 0.62 28.50 29.12 6.07 0.037 8-RH-1112-BB1-1 2.000 0.35 28.50 28.85 6.01 0.037 8-RH-1112-BB1-1A 2.000 0.92 28.50 29.42 6.13 0.037 8-RH-1112-BB1-2 2.000 1.26 28.50 29.76 6.20 0.038 8-RH-1208-BB1-1 2.000 0.27 28.50 28.77 5.99 0.037 8-RH-1208-BB1-2 2.000 0.43 28.50 28.93 6.03 0.037 8-RH-1212-BB1-1 2.000 0.52 28.50 29.02 6.05 0.037 8-RH-1212-BB1-2 2.000 0.84 28.50 29.34 6.11 0.037 8-RH-1308-BB1-1 2.000 0.47 28.50 28.97 6.04 0.037 8-RH-1308-BB1-2 2.000 0.74 28.50 29.24 6.09 0.037 8-RH-1315-BB1-1 2.000 1.19 28.50 29.69 6.19 0.038 8-SI-1108-BB1-1 2.000 1.13 28.50 29.63 6.17 0.038 8-SI-1108-BB1-2 2.000 1.49 28.50 29.99 6.25 0.038 8-SI-1108-BB1-3 2.000 1.52 28.50 30.02 6.25 0.038 8-SI-1108-BB1-4 2.000 0.39 28.50 28.89 6.02 0.037 8-SI-1108-BB1-5 2.000 0.51 28.50 29.01 6.04 0.037 8-SI-1208-BB1-1 2.000 0.52 28.50 29.02 6.05 0.037 8-SI-1208-BB1-2 2.000 0.70 28.50 29.20 6.08 0.037 8-SI-1208-BB1-3 2.000 0.90 28.50 29.40 6.12 0.037 8-SI-1208-BB1-3A 2.000 0.60 28.50 29.10 6.06 0.037 8-SI-1208-BB1-4 2.000 0.92 28.50 29.42 6.13 0.037 8-SI-1327-BB1-1 2.000 1.38 28.50 29.88 6.23 0.038 8-SI-1327-BB1-2 2.000 1.38 28.50 29.88 6.23 0.038 8-SI-1327-BB1-3 2.000 1.36 28.50 29.86 6.22 0.038 8-SI-1327-BB1-4 2.000 1.04 28.50 29.54 6.15 0.038 8-SI-1327-BB1-5 2.000 0.84 28.50 29.34 6.11 0.037 8-SI-1327-BB1-6 2.000 0.85 28.50 29.35 6.12 0.037
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 2-Train (ft^3 per strainer)
Bed Thickness 2-Train (in) 8-SI-1327-BB1-7 2.000 0.78 28.50 29.28 6.10 0.037 8-SI-1327-BB1-8 2.000 0.77 28.50 29.27 6.10 0.037 8-SI-1327-BB1-9 2.000 0.66 28.50 29.16 6.07 0.037 8-SI-1327-BB1-10 2.000 0.77 28.50 29.27 6.10 0.037 8-SI-1327-BB1-11 2.000 0.64 28.50 29.14 6.07 0.037 10-RH-1108-BB1-1 2.000 0.62 28.50 29.12 6.07 0.037 10-RH-1108-BB1-1A 2.000 0.80 28.50 29.30 6.10 0.037 10-RH-1108-BB1-2 2.000 0.83 28.50 29.33 6.11 0.037 10-RH-1108-BB1-3 2.000 0.71 28.50 29.21 6.09 0.037 10-RH-1108-BB1-4 2.000 0.64 28.50 29.14 6.07 0.037 10-RH-1108-BB1-5 2.000 0.73 28.50 29.23 6.09 0.037 10-RH-1108-BB1-6 2.000 0.73 28.50 29.23 6.09 0.037 10-RH-1108-BB1-7 2.000 0.69 28.50 29.19 6.08 0.037 10-RH-1108-BB1-8 2.000 0.77 28.50 29.27 6.10 0.037 10-RH-1108-BB1-9 2.000 0.82 28.50 29.32 6.11 0.037 10-RH-1108-BB1-10 2.000 0.85 28.50 29.35 6.12 0.037 10-RH-1208-BB1-1 2.000 0.43 28.50 28.93 6.03 0.037 10-RH-1208-BB1-2 2.000 0.53 28.50 29.03 6.05 0.037 10-RH-1208-BB1-3 2.000 0.53 28.50 29.03 6.05 0.037 10-RH-1208-BB1-4 2.000 0.64 28.50 29.14 6.07 0.037 10-RH-1208-BB1-5 2.000 0.73 28.50 29.23 6.09 0.037 10-RH-1208-BB1-6 2.000 0.73 28.50 29.23 6.09 0.037 10-RH-1208-BB1-7 2.000 0.66 28.50 29.16 6.08 0.037 10-RH-1208-BB1-8 2.000 0.60 28.50 29.10 6.06 0.037 10-RH-1208-BB1-9 2.000 0.68 28.50 29.18 6.08 0.037
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 2-Train (ft^3 per strainer)
Bed Thickness 2-Train (in) 10-RH-1208-BB1-10 2.000 0.72 28.50 29.22 6.09 0.037 10-RH-1208-BB1-11 2.000 0.81 28.50 29.31 6.11 0.037 10-RH-1308-BB1-1 2.000 0.73 28.50 29.23 6.09 0.037 10-RH-1308-BB1-2 2.000 0.71 28.50 29.21 6.09 0.037 10-RH-1308-BB1-3 2.000 0.72 28.50 29.22 6.09 0.037 10-RH-1308-BB1-4 2.000 0.66 28.50 29.16 6.08 0.037 10-RH-1308-BB1-5 2.000 0.63 28.50 29.13 6.07 0.037 10-RH-1308-BB1-6 2.000 0.63 28.50 29.13 6.07 0.037 10-RH-1308-BB1-7 2.000 0.61 28.50 29.11 6.07 0.037 10-RH-1308-BB1-8 2.000 0.72 28.50 29.22 6.09 0.037 12-RC-1112-BB1-1 2.000 2.44 28.50 30.94 6.45 0.039 12-RC-1112-BB1-2 2.000 1.86 28.50 30.36 6.32 0.039 12-RC-1112-BB1-3 2.000 1.53 28.50 30.03 6.26 0.038 12-RC-1112-BB1-4 2.000 1.73 28.50 30.23 6.30 0.038 12-RC-1112-BB1-5 2.000 1.79 28.50 30.29 6.31 0.039 12-RC-1112-BB1-6 2.000 1.77 28.50 30.27 6.31 0.039 12-RC-1112-BB1-7 2.000 1.75 28.50 30.25 6.30 0.039 12-RC-1112-BB1-8 2.000 1.83 28.50 30.33 6.32 0.039 12-RC-1112-BB1-9 2.000 2.07 28.50 30.57 6.37 0.039 12-RC-1112-BB1-10 2.000 1.83 28.50 30.33 6.32 0.039 12-RC-1112-BB1-11 2.000 1.60 28.50 30.10 6.27 0.038 12-RC-1125-BB1-1 2.000 1.93 28.50 30.43 6.34 0.039 12-RC-1125-BB1-2 2.000 2.49 28.50 30.99 6.46 0.039 12-RC-1125-BB1-3 2.000 2.18 28.50 30.68 6.39 0.039
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 2-Train (ft^3 per strainer)
Bed Thickness 2-Train (in) 12-RC-1125-BB1-4 2.000 1.41 28.50 29.91 6.23 0.038 12-RC-1125-BB1-5 2.000 1.54 28.50 30.04 6.26 0.038 12-RC-1125-BB1-6 2.000 1.75 28.50 30.25 6.30 0.039 12-RC-1125-BB1-7 2.000 1.90 28.50 30.40 6.33 0.039 12-RC-1125-BB1-8 2.000 1.05 28.50 29.55 6.16 0.038 12-RC-1125-BB1-9 2.000 1.57 28.50 30.07 6.26 0.038 12-RC-1125-BB1-10 2.000 1.89 28.50 30.39 6.33 0.039 12-RC-1125-BB1-11 2.000 1.42 28.50 29.92 6.23 0.038 12-RC-1125-BB1-12 2.000 1.37 28.50 29.87 6.22 0.038 12-RC-1125-BB1-13 2.000 2.04 28.50 30.54 6.36 0.039 12-RC-1212-BB1-1 2.000 2.30 28.50 30.80 6.42 0.039 12-RC-1212-BB1-2 2.000 1.99 28.50 30.49 6.35 0.039 12-RC-1212-BB1-3 2.000 1.70 28.50 30.20 6.29 0.038 12-RC-1212-BB1-4 2.000 1.78 28.50 30.28 6.31 0.039 12-RC-1212-BB1-5 2.000 1.80 28.50 30.30 6.31 0.039 12-RC-1212-BB1-6 2.000 1.71 28.50 30.21 6.29 0.038 12-RC-1212-BB1-7 2.000 1.70 28.50 30.20 6.29 0.038 12-RC-1212-BB1-8 2.000 1.83 28.50 30.33 6.32 0.039 12-RC-1221-BB1-1 2.000 1.62 28.50 30.12 6.27 0.038 12-RC-1221-BB1-2 2.000 1.88 28.50 30.38 6.33 0.039 12-RC-1221-BB1-3 2.000 1.61 28.50 30.11 6.27 0.038 12-RC-1221-BB1-4 2.000 1.87 28.50 30.37 6.33 0.039 12-RC-1221-BB1-5 2.000 1.85 28.50 30.35 6.32 0.039 12-RC-1221-BB1-6 2.000 1.75 28.50 30.25 6.30 0.039
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 2-Train (ft^3 per strainer)
Bed Thickness 2-Train (in) 12-RC-1221-BB1-7 2.000 1.68 28.50 30.18 6.29 0.038 12-RC-1221-BB1-8 2.000 1.16 28.50 29.66 6.18 0.038 12-RC-1221-BB1-9 2.000 1.75 28.50 30.25 6.30 0.039 12-RC-1221-BB1-10 2.000 1.90 28.50 30.40 6.33 0.039 12-RC-1221-BB1-11 2.000 1.74 28.50 30.24 6.30 0.039 12-RC-1221-BB1-12 2.000 1.40 28.50 29.90 6.23 0.038 12-RC-1221-BB1-13 2.000 1.39 28.50 29.89 6.23 0.038 12-RC-1221-BB1-14 2.000 2.02 28.50 30.52 6.36 0.039 12-RC-1312-BB1-1 2.000 2.23 28.50 30.73 6.40 0.039 12-RC-1312-BB1-2 2.000 1.99 28.50 30.49 6.35 0.039 12-RC-1312-BB1-3 2.000 1.69 28.50 30.19 6.29 0.038 12-RC-1312-BB1-4 2.000 1.79 28.50 30.29 6.31 0.039 12-RC-1312-BB1-5 2.000 1.89 28.50 30.39 6.33 0.039 12-RC-1312-BB1-6 2.000 1.62 28.50 30.12 6.27 0.038 12-RC-1312-BB1-7 2.000 1.68 28.50 30.18 6.29 0.038 12-RC-1312-BB1-8 2.000 1.35 28.50 29.85 6.22 0.038 12-RC-1312-BB1-9 2.000 2.13 28.50 30.63 6.38 0.039 12-RC-1312-BB1-10 2.000 2.23 28.50 30.73 6.40 0.039 12-RC-1312-BB1-11 2.000 1.55 28.50 30.05 6.26 0.038 12-RC-1322-BB1-1 2.000 1.75 28.50 30.25 6.30 0.039 12-RC-1322-BB1-1A 2.000 1.08 28.50 29.58 6.16 0.038 12-RC-1322-BB1-2 2.000 1.35 28.50 29.85 6.22 0.038 12-RC-1322-BB1-3 2.000 1.34 28.50 29.84 6.22 0.038 12-RC-1322-BB1-4 2.000 1.95 28.50 30.45 6.34 0.039
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 2-Train (ft^3 per strainer)
Bed Thickness 2-Train (in) 12-RH-1101-BB1-1 2.000 1.34 28.50 29.84 6.22 0.038 12-RH-1101-BB1-2 2.000 0.68 28.50 29.18 6.08 0.037 12-RH-1101-BB1-3 2.000 0.70 28.50 29.20 6.08 0.037 12-RH-1101-BB1-3A 2.000 0.81 28.50 29.31 6.11 0.037 12-RH-1101-BB1-4 2.000 0.50 28.50 29.00 6.04 0.037 12-RH-1101-BB1-5 2.000 0.69 28.50 29.19 6.08 0.037 12-RH-1101-BB1-6 2.000 0.70 28.50 29.20 6.08 0.037 12-RH-1101-BB1-7 2.000 1.13 28.50 29.63 6.17 0.038 12-RH-1101-BB1-8 2.000 0.78 28.50 29.28 6.10 0.037 12-RH-1101-BB1-9 2.000 0.52 28.50 29.02 6.05 0.037 12-RH-1101-BB1-10 2.000 1.46 28.50 29.96 6.24 0.038 12-RH-1101-BB1-11 2.000 1.16 28.50 29.66 6.18 0.038 12-RH-1101-BB1-12 2.000 1.11 28.50 29.61 6.17 0.038 12-RH-1101-BB1-13 2.000 0.90 28.50 29.40 6.13 0.037 12-RH-1101-BB1-14 2.000 0.98 28.50 29.48 6.14 0.038 12-RH-1101-BB1-15 2.000 1.10 28.50 29.60 6.17 0.038 12-RH-1101-BB1-16 2.000 0.96 28.50 29.46 6.14 0.038 12-RH-1201-BB1-1 2.000 1.06 28.50 29.56 6.16 0.038 12-RH-1201-BB1-2 2.000 1.01 28.50 29.51 6.15 0.038 12-RH-1201-BB1-3 2.000 1.11 28.50 29.61 6.17 0.038 12-RH-1201-BB1-4 2.000 1.44 28.50 29.94 6.24 0.038 12-RH-1201-BB1-5 2.000 1.38 28.50 29.88 6.22 0.038 12-RH-1201-BB1-6 2.000 1.19 28.50 29.69 6.18 0.038 12-RH-1201-BB1-7 2.000 1.13 28.50 29.63 6.17 0.038
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 2-Train (ft^3 per strainer)
Bed Thickness 2-Train (in) 12-RH-1201-BB1-8 2.000 1.15 28.50 29.65 6.18 0.038 12-RH-1201-BB1-9 2.000 1.35 28.50 29.85 6.22 0.038 12-RH-1201-BB1-10 2.000 0.86 28.50 29.36 6.12 0.037 12-RH-1201-BB1-11 2.000 0.68 28.50 29.18 6.08 0.037 12-RH-1201-BB1-12 2.000 1.05 28.50 29.55 6.16 0.038 12-RH-1201-BB1-13 2.000 0.96 28.50 29.46 6.14 0.038 12-RH-1201-BB1-14 2.000 0.72 28.50 29.22 6.09 0.037 12-RH-1201-BB1-15 2.000 0.74 28.50 29.24 6.09 0.037 12-RH-1201-BB1-16 2.000 0.71 28.50 29.21 6.09 0.037 12-RH-1201-BB1-17 2.000 0.68 28.50 29.18 6.08 0.037 12-RH-1301-BB1-1 2.000 1.09 28.50 29.59 6.17 0.038 12-RH-1301-BB1-2 2.000 0.87 28.50 29.37 6.12 0.037 12-RH-1301-BB1-3 2.000 0.86 28.50 29.36 6.12 0.037 12-RH-1301-BB1-4 2.000 1.22 28.50 29.72 6.19 0.038 12-RH-1301-BB1-5 2.000 0.94 28.50 29.44 6.13 0.037 12-RH-1301-BB1-5A 2.000 0.73 28.50 29.23 6.09 0.037 12-RH-1301-BB1-6 2.000 0.84 28.50 29.34 6.11 0.037 12-RH-1301-BB1-7 2.000 0.81 28.50 29.31 6.11 0.037 12-RH-1301-BB1-8 2.000 0.72 28.50 29.22 6.09 0.037 12-RH-1301-BB1-9 2.000 0.71 28.50 29.21 6.09 0.037 12-RH-1301-BB1-10 2.000 0.67 28.50 29.17 6.08 0.037 12-SI-1125-BB1-1 2.000 0.65 28.50 29.15 6.07 0.037 12-SI-1125-BB1-2 2.000 0.89 28.50 29.39 6.12 0.037 12-SI-1125-BB1-3 2.000 1.09 28.50 29.59 6.17 0.038
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 2-Train (ft^3 per strainer)
Bed Thickness 2-Train (in) 12-SI-1125-BB1-4 2.000 1.18 28.50 29.68 6.18 0.038 12-SI-1218-BB1-1 2.000 0.68 28.50 29.18 6.08 0.037 12-SI-1218-BB1-2 2.000 0.97 28.50 29.47 6.14 0.038 12-SI-1218-BB1-3 2.000 0.98 28.50 29.48 6.14 0.038 12-SI-1218-BB1-4 2.000 0.98 28.50 29.48 6.14 0.038 12-SI-1315-BB1-1 2.000 0.41 28.50 28.91 6.02 0.037 12-SI-1315-BB1-2 2.000 0.76 28.50 29.26 6.10 0.037 12-SI-1315-BB1-3 2.000 0.92 28.50 29.42 6.13 0.037 12-SI-1315-BB1-4 2.000 0.97 28.50 29.47 6.14 0.038 12-SI-1315-BB1-5 2.000 0.93 28.50 29.43 6.13 0.037 12-SI-1315-BB1-6 2.000 0.49 28.50 28.99 6.04 0.037 12-SI-1315-BB1-7 2.000 0.56 28.50 29.06 6.05 0.037 12-SI-1315-BB1-8 2.000 1.50 28.50 30.00 6.25 0.038 12-SI-1315-BB1-9 2.000 1.83 28.50 30.33 6.32 0.039 12-SI-1315-BB1-10 2.000 2.18 28.50 30.68 6.39 0.039 16-RC-1412-NSS-1 2.000 1.13 28.50 29.63 6.17 0.038 16-RC-1412-NSS-3 2.000 2.16 28.50 30.66 6.39 0.039 16-RC-1412-NSS-4 2.000 2.19 28.50 30.69 6.39 0.039 16-RC-1412-NSS-5 2.000 1.77 28.50 30.27 6.31 0.039 16-RC-1412-NSS-6 2.000 2.29 28.50 30.79 6.41 0.039 16-RC-1412-NSS-7 2.000 2.61 28.50 31.11 6.48 0.040 16-RC-1412-NSS-8 2.000 1.98 28.50 30.48 6.35 0.039 16-RC-1412-NSS-9 2.000 2.90 28.50 31.40 6.54 0.040 16-RC-1412-NSS-PRZ-1-N1-SE 2.000 1.18 28.50 29.68 6.18 0.038
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 2-Train (ft^3 per strainer)
Bed Thickness 2-Train (in) 27.5-RC-1103-NSS-1 2.000 2.06 28.50 30.56 6.37 0.039 27.5-RC-1103-NSS-3 2.000 1.66 28.50 30.16 6.28 0.038 27.5-RC-1103-NSS-4 2.000 2.19 28.50 30.69 6.39 0.039 27.5-RC-1103-NSS-5 2.000 1.64 28.50 30.14 6.28 0.038 27.5-RC-1103-NSS-6 2.000 1.71 28.50 30.21 6.29 0.038 27.5-RC-1103-NSS-7 2.000 1.50 28.50 30.00 6.25 0.038 27.5-RC-1103-NSS-RPV1-N2ASE 2.000 1.03 28.50 29.53 6.15 0.038 27.5-RC-1203-NSS-1 2.000 1.79 28.50 30.29 6.31 0.039 27.5-RC-1203-NSS-3 2.000 2.58 28.50 31.08 6.47 0.040 27.5-RC-1203-NSS-4 2.000 1.70 28.50 30.20 6.29 0.038 27.5-RC-1203-NSS-5 2.000 1.09 28.50 29.59 6.17 0.038 27.5-RC-1203-NSS-RPV1-N2BSE 2.000 1.03 28.50 29.53 6.15 0.038 27.5-RC-1303-NSS-1 2.000 1.79 28.50 30.29 6.31 0.039 27.5-RC-1303-NSS-3 2.000 2.49 28.50 30.99 6.46 0.039 27.5-RC-1303-NSS-4 2.000 1.51 28.50 30.01 6.25 0.038 27.5-RC-1303-NSS-5 2.000 1.71 28.50 30.21 6.29 0.038 27.5-RC-1303-NSS-6 2.000 1.13 28.50 29.63 6.17 0.038 27.5-RC-1303-NSS-RPV1-N2CSE 2.000 1.03 28.50 29.53 6.15 0.038 27.5-RC-1403-NSS-1 2.000 1.90 28.50 30.40 6.33 0.039 27.5-RC-1403-NSS-3 2.000 1.98 28.50 30.48 6.35 0.039 27.5-RC-1403-NSS-4 2.000 1.84 28.50 30.34 6.32 0.039 27.5-RC-1403-NSS-5 2.000 1.71 28.50 30.21 6.29 0.038 27.5-RC-1403-NSS-6 2.000 1.08 28.50 29.58 6.16 0.038
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 2-Train (ft^3 per strainer)
Bed Thickness 2-Train (in) 27.5-RC-1403-NSS-RPV1-N2DSE 2.000 1.02 28.50 29.52 6.15 0.038 29-RC-1101-NSS-1 2.000 1.24 28.50 29.74 6.20 0.038 29-RC-1101-NSS-2 2.000 2.51 28.50 31.01 6.46 0.039 29-RC-1101-NSS-3 2.000 2.74 28.50 31.24 6.51 0.040 29-RC-1101-NSS-4 2.000 2.13 28.50 30.63 6.38 0.039 29-RC-1101-NSS-5.1 2.000 2.18 28.50 30.68 6.39 0.039 29-RC-1101-NSS-RPV1-N1ASE 2.000 0.98 28.50 29.48 6.14 0.038 29-RC-1101-NSS-RSG-1A-IN-SE 2.000 2.20 28.50 30.70 6.40 0.039 29-RC-1201-NSS-1 2.000 1.24 28.50 29.74 6.20 0.038 29-RC-1201-NSS-2 2.000 2.57 28.50 31.07 6.47 0.040 29-RC-1201-NSS-3 2.000 2.74 28.50 31.24 6.51 0.040 29-RC-1201-NSS-4 2.000 2.13 28.50 30.63 6.38 0.039 29-RC-1201-NSS-5.1 2.000 2.17 28.50 30.67 6.39 0.039 29-RC-1201-RPV1-N1BSE 2.000 0.98 28.50 29.48 6.14 0.038 29-RC-1201-RSG-1B-IN-SE 2.000 2.16 28.50 30.66 6.39 0.039 29-RC-1301-NSS-1 2.000 1.24 28.50 29.74 6.20 0.038 29-RC-1301-NSS-2 2.000 2.45 28.50 30.95 6.45 0.039 29-RC-1301-NSS-3 2.000 2.75 28.50 31.25 6.51 0.040 29-RC-1301-NSS-4 2.000 2.13 28.50 30.63 6.38 0.039 29-RC-1301-NSS-5.1 2.000 2.24 28.50 30.74 6.40 0.039 29-RC-1301-RPV1-N1CSE 2.000 0.98 28.50 29.48 6.14 0.038 29-RC-1301-RSG-1C-IN-SE 2.000 2.24 28.50 30.74 6.40 0.039 29-RC-1401-NSS-1 2.000 1.24 28.50 29.74 6.20 0.038
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 2-Train (ft^3 per strainer)
Bed Thickness 2-Train (in) 29-RC-1401-NSS-2 2.000 3.01 28.50 31.51 6.57 0.040 29-RC-1401-NSS-3 2.000 2.50 28.50 31.00 6.46 0.039 29-RC-1401-NSS-4.1 2.000 2.14 28.50 30.64 6.38 0.039 29-RC-1401-NSS-RPV1-N1DSE 2.000 0.98 28.50 29.48 6.14 0.038 29-RC-1401-NSS-RSG-1D-IN-SE 2.000 2.16 28.50 30.66 6.39 0.039 31-RC-1102-NSS-1.1 2.000 1.97 28.50 30.47 6.35 0.039 31-RC-1102-NSS-2 2.000 1.93 28.50 30.43 6.34 0.039 31-RC-1102-NSS-3 2.000 1.89 28.50 30.39 6.33 0.039 31-RC-1102-NSS-4 2.000 1.81 28.50 30.31 6.32 0.039 31-RC-1102-NSS-5 1.689 1.64 28.50 30.14 6.28 0.038 31-RC-1102-NSS-6 1.689 2.02 28.50 30.52 6.36 0.039 31-RC-1102-NSS-7 2.000 1.32 28.50 29.82 6.21 0.038 31-RC-1102-NSS-8 2.000 1.86 28.50 30.36 6.32 0.039 31-RC-1102-NSS-9 2.000 1.82 28.50 30.32 6.32 0.039 31-RC-1102-NSS-RSG-1A-ON-SE 2.000 1.97 28.50 30.47 6.35 0.039 31-RC-1202-NSS-1.1 2.000 2.00 28.50 30.50 6.35 0.039 31-RC-1202-NSS-2 2.000 1.93 28.50 30.43 6.34 0.039 31-RC-1202-NSS-3 2.000 1.89 28.50 30.39 6.33 0.039 31-RC-1202-NSS-4 2.000 1.82 28.50 30.32 6.32 0.039 31-RC-1202-NSS-5 1.689 1.65 28.50 30.15 6.28 0.038 31-RC-1202-NSS-6 2.000 1.35 28.50 29.85 6.22 0.038 31-RC-1202-NSS-7 1.689 1.97 28.50 30.47 6.35 0.039 31-RC-1202-NSS-8 2.000 1.85 28.50 30.35 6.32 0.039
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 2-Train (ft^3 per strainer)
Bed Thickness 2-Train (in) 31-RC-1202-NSS-9 2.000 1.83 28.50 30.33 6.32 0.039 31-RC-1202-NSS-RSG-1B-ON-SE 2.000 2.00 28.50 30.50 6.35 0.039 31-RC-1302-NSS-1.1 2.000 1.97 28.50 30.47 6.35 0.039 31-RC-1302-NSS-2 2.000 1.93 28.50 30.43 6.34 0.039 31-RC-1302-NSS-3 2.000 1.90 28.50 30.40 6.33 0.039 31-RC-1302-NSS-4 2.000 1.82 28.50 30.32 6.32 0.039 31-RC-1302-NSS-5 1.689 1.68 28.50 30.18 6.29 0.038 31-RC-1302-NSS-6 2.000 1.29 28.50 29.79 6.21 0.038 31-RC-1302-NSS-7 2.000 1.73 28.50 30.23 6.30 0.039 31-RC-1302-NSS-8 2.000 1.92 28.50 30.42 6.34 0.039 31-RC-1302-NSS-9 2.000 1.82 28.50 30.32 6.32 0.039 31-RC-1302-NSS-RSG-1C-ON-SE 2.000 2.06 28.50 30.56 6.37 0.039 31-RC-1402-NSS-1.1 2.000 1.96 28.50 30.46 6.34 0.039 31-RC-1402-NSS-2 2.000 1.93 28.50 30.43 6.34 0.039 31-RC-1402-NSS-3 2.000 1.89 28.50 30.39 6.33 0.039 31-RC-1402-NSS-4 2.000 1.82 28.50 30.32 6.32 0.039 31-RC-1402-NSS-5 1.689 1.64 28.50 30.14 6.28 0.038 31-RC-1402-NSS-6 2.000 1.37 28.50 29.87 6.22 0.038 31-RC-1402-NSS-7 1.689 1.94 28.50 30.44 6.34 0.039 31-RC-1402-NSS-8 2.000 1.86 28.50 30.36 6.32 0.039 31-RC-1402-NSS-9 2.000 1.88 28.50 30.38 6.33 0.039 31-RC-1402-NSS-RSG-1D-ON-SE 2.000 1.96 28.50 30.46 6.35 0.039
DRAFT Supplement to Follow up SSIB RAI 37 Table 2: SBLOCA Max Transported Fiber Mass, Volume, and Expected Bed Thickness for One Train Cases Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 1-Train (ft^3 per strainer)
Bed Thickness 1-Train (in) 0.75-CV-1122-BB1-1 0.614 0.05 28.50 28.55 11.89 0.073 0.75-CV-1122-BB1-2 0.614 0.05 28.50 28.55 11.89 0.073 0.75-CV-1124-BB1-1 0.614 0.00 28.50 28.50 11.88 0.073 0.75-CV-1124-BB1-2 0.614 0.00 28.50 28.50 11.88 0.073 0.75-CV-1126-BB1-1 0.614 0.00 28.50 28.50 11.88 0.073 0.75-CV-1126-BB1-2 0.614 0.18 28.50 28.68 11.95 0.073 0.75-CV-1128-BB1-1 0.614 0.00 28.50 28.50 11.88 0.073 0.75-CV-1128-BB1-2 0.614 0.00 28.50 28.50 11.88 0.073 0.75-RC-1001-BB1-1 0.614 0.24 28.50 28.74 11.97 0.073 0.75-RC-1002-BB2-1 0.614 0.29 28.50 28.79 11.99 0.073 0.75-RC-1112-BB1-1 0.614 0.29 28.50 28.79 11.99 0.073 0.75-RC-1114-BB1-1 0.614 0.44 28.50 28.94 12.06 0.074 0.75-RC-1125-BB1-1 0.614 0.28 28.50 28.78 11.99 0.073 0.75-RC-1125-BB1-2 0.614 0.37 28.50 28.87 12.03 0.074 0.75-RC-1126-BB1-1 0.614 0.35 28.50 28.85 12.02 0.073 0.75-RC-1212-BB1-1 0.614 0.34 28.50 28.84 12.02 0.073 0.75-RC-1214-BB1-1 0.614 0.38 28.50 28.88 12.03 0.074 0.75-RC-1221-BB1-1 0.614 0.29 28.50 28.79 11.99 0.073 0.75-RC-1221-BB1-2 0.614 0.29 28.50 28.79 12.00 0.073 0.75-RC-1312-BB1-1 0.614 0.33 28.50 28.83 12.01 0.073 0.75-RC-1324-BB1-1 0.614 0.43 28.50 28.93 12.05 0.074 0.75-RC-1423-BB1-1 0.614 0.53 28.50 29.03 12.10 0.074
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 1-Train (ft^3 per strainer)
Bed Thickness 1-Train (in) 0.75-SI-1130-BB2-1 0.614 0.25 28.50 28.75 11.98 0.073 0.75-SI-1132-BB1-1 0.614 0.15 28.50 28.65 11.94 0.073 0.75-SI-1218-BB1-1 0.614 0.18 28.50 28.68 11.95 0.073 0.75-SI-1223-BB2-1 0.614 0.24 28.50 28.74 11.97 0.073 0.75-SI-1315-BB1-1 0.614 0.38 28.50 28.88 12.03 0.074 0.75-SI-1323-BB1-1 0.614 0.17 28.50 28.67 11.95 0.073 0.75-SI-1327-BB1-1 0.614 0.21 28.50 28.71 11.96 0.073 0.75-SI-1327-BB1-2 0.614 0.20 28.50 28.70 11.96 0.073 0.75-SI-1327-BB1-3 0.614 0.19 28.50 28.69 11.95 0.073 0.75-SI-1328-BB2-1 0.614 0.24 28.50 28.74 11.97 0.073 1-RC-1003-BB1-1 0.815 0.78 28.50 29.28 12.20 0.075 1-RC-1123-BB1-1 0.815 0.36 28.50 28.86 12.02 0.074 1-RC-1422-BB1-1 0.815 0.66 28.50 29.16 12.15 0.074 1.5-RC-1412-NSS-1 1.338 1.86 28.50 30.36 12.65 0.077 2(1.5)-CV-1122-BB1-1 1.338 0.08 28.50 28.58 11.91 0.073 2(1.5)-CV-1122-BB1-2 1.338 0.25 28.50 28.75 11.98 0.073 2(1.5)-CV-1124-BB1-1 1.338 0.07 28.50 28.57 11.91 0.073 2(1.5)-CV-1124-BB1-2 1.338 0.37 28.50 28.87 12.03 0.074 2(1.5)-CV-1126-BB1-1 1.338 0.58 28.50 29.08 12.12 0.074 2(1.5)-CV-1126-BB1-2 1.338 0.57 28.50 29.07 12.11 0.074 2(1.5)-CV-1128-BB1-1 1.338 0.25 28.50 28.75 11.98 0.073 2(1.5)-CV-1128-BB1-2 1.338 0.52 28.50 29.02 12.09 0.074 2-CV-1121-BB1-1 1.689 0.26 28.50 28.76 11.98 0.073 2-CV-1121-BB1-2 1.689 0.53 28.50 29.03 12.10 0.074
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 1-Train (ft^3 per strainer)
Bed Thickness 1-Train (in) 2-CV-1121-BB1-3 1.689 0.77 28.50 29.27 12.19 0.075 2-CV-1122-BB1-1 1.689 0.92 28.50 29.42 12.26 0.075 2-CV-1122-BB1-2 1.689 0.85 28.50 29.35 12.23 0.075 2-CV-1122-BB1-3 1.689 0.78 28.50 29.28 12.20 0.075 2-CV-1122-BB1-4 1.689 0.75 28.50 29.25 12.19 0.075 2-CV-1122-BB1-5 1.689 0.82 28.50 29.32 12.22 0.075 2-CV-1122-BB1-6 1.689 0.45 28.50 28.95 12.06 0.074 2-CV-1124-BB1-1 1.689 0.76 28.50 29.26 12.19 0.075 2-CV-1124-BB1-2 1.689 0.79 28.50 29.29 12.20 0.075 2-CV-1124-BB1-3 1.689 0.79 28.50 29.29 12.20 0.075 2-CV-1124-BB1-4 1.689 0.91 28.50 29.41 12.25 0.075 2-CV-1124-BB1-5 1.689 1.00 28.50 29.50 12.29 0.075 2-CV-1124-BB1-6 1.689 0.95 28.50 29.45 12.27 0.075 2-CV-1124-BB1-7 1.689 0.79 28.50 29.29 12.21 0.075 2-CV-1124-BB1-8 1.689 0.78 28.50 29.28 12.20 0.075 2-CV-1124-BB1-9 1.689 0.84 28.50 29.34 12.22 0.075 2-CV-1124-BB1-10 1.689 0.88 28.50 29.38 12.24 0.075 2-CV-1124-BB1-11 1.689 0.84 28.50 29.34 12.22 0.075 2-CV-1124-BB1-12 1.689 0.36 28.50 28.86 12.03 0.074 2-CV-1124-BB1-13 1.689 0.39 28.50 28.89 12.04 0.074 2-CV-1126-BB1-1 1.689 0.24 28.50 28.74 11.97 0.073 2-CV-1126-BB1-2 1.689 0.29 28.50 28.79 12.00 0.073 2-CV-1126-BB1-3 1.689 0.34 28.50 28.84 12.02 0.073 2-CV-1126-BB1-4 1.689 0.38 28.50 28.88 12.03 0.074
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 1-Train (ft^3 per strainer)
Bed Thickness 1-Train (in) 2-CV-1126-BB1-5 1.689 0.37 28.50 28.87 12.03 0.074 2-CV-1126-BB1-6 1.689 0.40 28.50 28.90 12.04 0.074 2-CV-1126-BB1-7 1.689 0.50 28.50 29.00 12.08 0.074 2-CV-1126-BB1-8 1.689 1.49 28.50 29.99 12.50 0.076 2-CV-1126-BB1-9 1.689 1.60 28.50 30.10 12.54 0.077 2-CV-1126-BB1-10 1.689 0.93 28.50 29.43 12.26 0.075 2-CV-1126-BB1-11 1.689 0.86 28.50 29.36 12.23 0.075 2-CV-1128-BB1-1 1.689 0.01 28.50 28.51 11.88 0.073 2-CV-1128-BB1-2 1.689 0.17 28.50 28.67 11.95 0.073 2-CV-1128-BB1-3 1.689 0.27 28.50 28.77 11.99 0.073 2-CV-1128-BB1-3A 1.689 0.32 28.50 28.82 12.01 0.073 2-CV-1128-BB1-3B 1.689 0.37 28.50 28.87 12.03 0.074 2-CV-1128-BB1-4 1.689 0.36 28.50 28.86 12.03 0.074 2-CV-1128-BB1-5 1.689 0.37 28.50 28.87 12.03 0.074 2-CV-1128-BB1-6 1.689 0.35 28.50 28.85 12.02 0.073 2-CV-1128-BB1-7 1.689 0.46 28.50 28.96 12.07 0.074 2-CV-1141-BB1-1 1.689 0.56 28.50 29.06 12.11 0.074 2-CV-1141-BB1-2 1.689 0.36 28.50 28.86 12.03 0.074 2-RC-1003-BB1-1 1.689 0.77 28.50 29.27 12.19 0.075 2-RC-1003-BB1-2 1.689 1.22 28.50 29.72 12.38 0.076 2-RC-1120-BB1-1 1.689 1.43 28.50 29.93 12.47 0.076 2-RC-1120-BB1-2 1.689 1.12 28.50 29.62 12.34 0.075 2-RC-1121-BB1-1 1.689 1.89 28.50 30.39 12.66 0.077 2-RC-1121-BB1-2 1.689 0.61 28.50 29.11 12.13 0.074
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 1-Train (ft^3 per strainer)
Bed Thickness 1-Train (in) 2-RC-1121-BB1-3 1.689 0.64 28.50 29.14 12.14 0.074 2-RC-1121-BB1-3A 1.689 0.62 28.50 29.12 12.13 0.074 2-RC-1121-BB1-3B 1.689 0.53 28.50 29.03 12.10 0.074 2-RC-1121-BB1-4 1.689 0.46 28.50 28.96 12.07 0.074 2-RC-1219-BB1-1 1.689 1.38 28.50 29.88 12.45 0.076 2-RC-1219-BB1-2 1.689 1.24 28.50 29.74 12.39 0.076 2-RC-1220-BB1-1 1.689 1.78 28.50 30.28 12.62 0.077 2-RC-1220-BB1-2 1.689 0.55 28.50 29.05 12.10 0.074 2-RC-1220-BB1-3 1.689 0.51 28.50 29.01 12.09 0.074 2-RC-1220-BB1-4 1.689 0.42 28.50 28.92 12.05 0.074 2-RC-1319-BB1-1 1.689 1.58 28.50 30.08 12.53 0.077 2-RC-1319-BB1-2 1.689 1.14 28.50 29.64 12.35 0.075 2-RC-1321-BB1-1 1.689 1.26 28.50 29.76 12.40 0.076 2-RC-1321-BB1-4 1.689 1.19 28.50 29.69 12.37 0.076 2-RC-1321-BB1-5 1.689 1.32 28.50 29.82 12.42 0.076 2-RC-1321-BB1-6 1.689 1.28 28.50 29.78 12.41 0.076 2-RC-1417-BB1-1 1.689 1.37 28.50 29.87 12.45 0.076 2-RC-1417-BB1-2 1.689 1.30 28.50 29.80 12.41 0.076 2-RC-1418-BB1-1 1.689 1.79 28.50 30.29 12.62 0.077 2-RC-1418-BB1-2 1.689 1.21 28.50 29.71 12.38 0.076 2-RC-1418-BB1-3 1.689 1.13 28.50 29.63 12.34 0.075 2-RC-1418-BB1-4 1.689 1.07 28.50 29.57 12.32 0.075 2-RC-1418-BB1-5 1.689 0.91 28.50 29.41 12.26 0.075 2-RC-1418-BB1-6 1.689 0.73 28.50 29.23 12.18 0.074
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 1-Train (ft^3 per strainer)
Bed Thickness 1-Train (in) 2-RC-1419-BB1-1 1.689 1.06 28.50 29.56 12.31 0.075 2-RC-1419-BB1-2 1.689 0.83 28.50 29.33 12.22 0.075 2-RC-1419-BB1-3 1.689 0.86 28.50 29.36 12.23 0.075 2-RC-1419-BB1-4 1.689 0.57 28.50 29.07 12.11 0.074 2.5-RC-1003-BB1-1 2.000 1.10 28.50 29.60 12.33 0.075 2.5-RC-1003-BB1-2 2.000 1.03 28.50 29.53 12.30 0.075 2.5-RC-1003-BB1-3 2.000 1.60 28.50 30.10 12.54 0.077 2.5-RC-1003-BB1-4 2.000 1.64 28.50 30.14 12.56 0.077 2.5-RC-1003-BB1-5 2.000 1.50 28.50 30.00 12.50 0.076 2.5-RC-1003-BB1-6 2.000 1.45 28.50 29.95 12.48 0.076 3-RC-1003-BB1-1 2.000 1.56 28.50 30.06 12.53 0.077 3-RC-1003-BB1-2 2.000 1.29 28.50 29.79 12.41 0.076 3-RC-1015-NSS-1 2.000 1.19 28.50 29.69 12.37 0.076 3-RC-1015-NSS-2 2.000 1.44 28.50 29.94 12.47 0.076 3-RC-1015-NSS-3 2.000 0.95 28.50 29.45 12.27 0.075 3-RC-1015-NSS-4 2.000 0.37 28.50 28.87 12.03 0.074 3-RC-1015-NSS-5 2.000 0.08 28.50 28.58 11.91 0.073 3-RC-1015-NSS-6 2.000 0.00 28.50 28.50 11.88 0.073 3-RC-1015-NSS-7 2.000 0.00 28.50 28.50 11.88 0.073 3-RC-1015-NSS-8 2.000 0.00 28.50 28.50 11.88 0.073 3-RC-1015-NSS-9 2.000 1.31 28.50 29.81 12.42 0.076 3-RC-1015-NSS-10 2.000 1.60 28.50 30.10 12.54 0.077 3-RC-1015-NSS-11 2.000 1.12 28.50 29.62 12.34 0.075 3-RC-1015-NSS-12 2.000 0.49 28.50 28.99 12.08 0.074 3-RC-1015-NSS-13 2.000 0.10 28.50 28.60 11.92 0.073 3-RC-1015-NSS-14 2.000 0.00 28.50 28.50 11.88 0.073 3-RC-1015-NSS-15 2.000 0.00 28.50 28.50 11.88 0.073 3-RC-1015-NSS-16 2.000 0.06 28.50 28.56 11.90 0.073
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 1-Train (ft^3 per strainer)
Bed Thickness 1-Train (in) 3-RC-1106-BB1-25 2.000 1.08 28.50 29.58 12.33 0.075 3-RC-1206-BB1-28 2.000 1.14 28.50 29.64 12.35 0.076 3-RC-1306-BB1-28 2.000 1.08 28.50 29.58 12.33 0.075 3-RC-1406-BB1-25 2.000 1.14 28.50 29.64 12.35 0.075 4-CV-1001-BB1-1 2.000 0.77 28.50 29.27 12.19 0.075 4-CV-1001-BB1-2 2.000 0.61 28.50 29.11 12.13 0.074 4-CV-1118-BB1-1 2.000 0.45 28.50 28.95 12.06 0.074 4-CV-1118-BB1-2 2.000 0.74 28.50 29.24 12.18 0.074 4-CV-1120-BB1-1 2.000 0.87 28.50 29.37 12.24 0.075 4-CV-1120-BB1-2 2.000 0.60 28.50 29.10 12.12 0.074 4-RC-1000-BB1-1 2.000 1.65 28.50 30.15 12.56 0.077 4-RC-1000-BB1-2 2.000 1.80 28.50 30.30 12.63 0.077 4-RC-1000-BB1-3 2.000 1.90 28.50 30.40 12.67 0.077 4-RC-1000-BB1-4 2.000 0.93 28.50 29.43 12.26 0.075 4-RC-1000-BB1-5 2.000 0.93 28.50 29.43 12.26 0.075 4-RC-1000-BB1-6 2.000 1.00 28.50 29.50 12.29 0.075 4-RC-1000-BB1-7 2.000 0.98 28.50 29.48 12.28 0.075 4-RC-1000-BB1-8 2.000 0.82 28.50 29.32 12.22 0.075 4-RC-1003-BB1-1 2.000 1.23 28.50 29.73 12.39 0.076 4-RC-1003-BB1-2 2.000 1.14 28.50 29.64 12.35 0.076 4-RC-1003-BB1-3 2.000 1.29 28.50 29.79 12.41 0.076 4-RC-1003-BB1-4 2.000 1.11 28.50 29.61 12.34 0.075 4-RC-1123-BB1-1 2.000 1.41 28.50 29.91 12.46 0.076 4-RC-1123-BB1-2 2.000 0.63 28.50 29.13 12.14 0.074
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 1-Train (ft^3 per strainer)
Bed Thickness 1-Train (in) 4-RC-1123-BB1-3 2.000 0.74 28.50 29.24 12.18 0.074 4-RC-1123-BB1-4 2.000 0.76 28.50 29.26 12.19 0.075 4-RC-1123-BB1-5 2.000 0.66 28.50 29.16 12.15 0.074 4-RC-1123-BB1-6 2.000 0.66 28.50 29.16 12.15 0.074 4-RC-1123-BB1-7 2.000 0.63 28.50 29.13 12.14 0.074 4-RC-1123-BB1-8 2.000 0.66 28.50 29.16 12.15 0.074 4-RC-1123-BB1-9 2.000 0.44 28.50 28.94 12.06 0.074 4-RC-1123-BB1-10 2.000 0.69 28.50 29.19 12.16 0.074 4-RC-1123-BB1-11 2.000 0.71 28.50 29.21 12.17 0.074 4-RC-1123-BB1-12 2.000 0.79 28.50 29.29 12.20 0.075 4-RC-1123-BB1-13 2.000 0.78 28.50 29.28 12.20 0.075 4-RC-1123-BB1-14 2.000 0.63 28.50 29.13 12.14 0.074 4-RC-1123-BB1-15 2.000 0.57 28.50 29.07 12.11 0.074 4-RC-1123-BB1-16 2.000 0.84 28.50 29.34 12.23 0.075 4-RC-1123-BB1-17 2.000 0.83 28.50 29.33 12.22 0.075 4-RC-1123-BB1-18 2.000 1.51 28.50 30.01 12.50 0.076 4-RC-1123-BB1-19 2.000 1.55 28.50 30.05 12.52 0.077 4-RC-1123-BB1-20 2.000 1.47 28.50 29.97 12.49 0.076 4-RC-1126-BB1-1 2.000 0.91 28.50 29.41 12.25 0.075 4-RC-1126-BB1-2 2.000 0.87 28.50 29.37 12.24 0.075 4-RC-1126-BB1-3 2.000 1.22 28.50 29.72 12.38 0.076 4-RC-1126-BB1-4 2.000 1.23 28.50 29.73 12.39 0.076 4-RC-1126-BB1-5 2.000 1.08 28.50 29.58 12.33 0.075 4-RC-1126-BB1-6 2.000 1.47 28.50 29.97 12.49 0.076
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 1-Train (ft^3 per strainer)
Bed Thickness 1-Train (in) 4-RC-1320-BB1-1 2.000 1.65 28.50 30.15 12.56 0.077 4-RC-1320-BB1-2 2.000 1.51 28.50 30.01 12.50 0.076 4-RC-1320-BB1-3 2.000 1.84 28.50 30.34 12.64 0.077 4-RC-1320-BB1-4 2.000 1.17 28.50 29.67 12.36 0.076 4-RC-1320-BB1-5 2.000 0.99 28.50 29.49 12.29 0.075 4-RC-1320-BB1-6 2.000 1.00 28.50 29.50 12.29 0.075 4-RC-1320-BB1-7 2.000 1.11 28.50 29.61 12.34 0.075 4-RC-1320-BB1-8 2.000 1.15 28.50 29.65 12.35 0.076 4-RC-1320-BB1-9 2.000 1.17 28.50 29.67 12.36 0.076 4-RC-1320-BB1-10 2.000 1.21 28.50 29.71 12.38 0.076 4-RC-1320-BB1-11 2.000 1.48 28.50 29.98 12.49 0.076 4-RC-1320-BB1-12 2.000 1.16 28.50 29.66 12.36 0.076 4-RC-1323-BB1-1 2.000 0.88 28.50 29.38 12.24 0.075 4-RC-1323-BB1-2 2.000 0.66 28.50 29.16 12.15 0.074 4-RC-1323-BB1-3 2.000 0.80 28.50 29.30 12.21 0.075 4-RC-1323-BB1-4 2.000 1.19 28.50 29.69 12.37 0.076 4-RC-1420-BB1-1 2.000 1.65 28.50 30.15 12.56 0.077 4-RC-1422-BB1-1 2.000 1.76 28.50 30.26 12.61 0.077 4-RC-1422-BB1-2 2.000 1.55 28.50 30.05 12.52 0.077 4-RC-1422-BB1-3 2.000 1.70 28.50 30.20 12.58 0.077 4-RC-1422-BB1-4 2.000 1.74 28.50 30.24 12.60 0.077 4-RC-1422-BB1-5 2.000 1.39 28.50 29.89 12.45 0.076 4-RC-1422-BB1-6 2.000 0.99 28.50 29.49 12.29 0.075 4-RC-1422-BB1-7 2.000 1.01 28.50 29.51 12.30 0.075
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 1-Train (ft^3 per strainer)
Bed Thickness 1-Train (in) 4-RC-1422-BB1-8 2.000 1.01 28.50 29.51 12.30 0.075 4-RC-1422-BB1-9 2.000 0.99 28.50 29.49 12.29 0.075 4-RC-1422-BB1-10 2.000 0.65 28.50 29.15 12.15 0.074 4-RC-1422-BB1-11 2.000 0.63 28.50 29.13 12.14 0.074 4-RC-1422-BB1-12 2.000 0.43 28.50 28.93 12.05 0.074 4-RC-1422-BB1-13 2.000 0.85 28.50 29.35 12.23 0.075 4-RC-1422-BB1-14 2.000 0.79 28.50 29.29 12.20 0.075 4-RC-1422-BB1-15 2.000 0.61 28.50 29.11 12.13 0.074 4-RC-1422-BB1-16 2.000 0.63 28.50 29.13 12.14 0.074 4-RC-1422-BB1-17 2.000 0.75 28.50 29.25 12.19 0.075 4-RC-1422-BB1-18 2.000 0.67 28.50 29.17 12.15 0.074 4-RC-1422-BB1-19 2.000 0.52 28.50 29.02 12.09 0.074 4-RC-1422-BB1-20 2.000 0.54 28.50 29.04 12.10 0.074 4-RC-1422-BB1-21 2.000 1.62 28.50 30.12 12.55 0.077 4-RC-1422-BB1-22 2.000 1.73 28.50 30.23 12.59 0.077 4-RC-1422-BB1-23 2.000 1.36 28.50 29.86 12.44 0.076 6-RC-1003-BB1-1 2.000 1.00 28.50 29.50 12.29 0.075 6-RC-1003-BB1-2 2.000 0.86 28.50 29.36 12.23 0.075 6-RC-1003-BB1-3 2.000 0.93 28.50 29.43 12.26 0.075 6-RC-1003-BB1-4 2.000 1.15 28.50 29.65 12.35 0.076 6-RC-1003-BB1-5 2.000 1.26 28.50 29.76 12.40 0.076 6-RC-1003-BB1-6 2.000 1.43 28.50 29.93 12.47 0.076 6-RC-1003-BB1-7 2.000 1.32 28.50 29.82 12.43 0.076 6-RC-1003-BB1-8 2.000 1.80 28.50 30.30 12.62 0.077
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 1-Train (ft^3 per strainer)
Bed Thickness 1-Train (in) 6-RC-1003-BB1-9 2.000 2.21 28.50 30.71 12.79 0.078 6-RC-1003-BB1-9A 2.000 1.80 28.50 30.30 12.62 0.077 6-RC-1003-BB1-9B 2.000 1.75 28.50 30.25 12.60 0.077 6-RC-1003-BB1-10 2.000 1.15 28.50 29.65 12.36 0.076 6-RC-1003-BB1-11 2.000 1.00 28.50 29.50 12.29 0.075 6-RC-1003-BB1-11A 2.000 1.28 28.50 29.78 12.41 0.076 6-RC-1003-BB1-11B 2.000 1.41 28.50 29.91 12.46 0.076 6-RC-1003-BB1-12 2.000 1.39 28.50 29.89 12.45 0.076 6-RC-1003-BB1-13 2.000 1.92 28.50 30.42 12.67 0.077 6-RC-1003-BB1-13A 2.000 2.24 28.50 30.74 12.81 0.078 6-RC-1003-BB1-14 2.000 2.53 28.50 31.03 12.93 0.079 6-RC-1003-BB1-PRZ-1-N2-SE 2.000 2.52 28.50 31.02 12.92 0.079 6-RC-1004-NSS-1 2.000 3.20 28.50 31.70 13.21 0.081 6-RC-1004-NSS-2 2.000 3.47 28.50 31.97 13.32 0.081 6-RC-1004-NSS-3 2.000 2.64 28.50 31.14 12.98 0.079 6-RC-1004-NSS-4 2.000 2.71 28.50 31.21 13.01 0.080 6-RC-1004-NSS-5 2.000 3.02 28.50 31.52 13.13 0.080 6-RC-1004-NSS-6 2.000 2.86 28.50 31.36 13.07 0.080 6-RC-1004-NSS-7 2.000 2.25 28.50 30.75 12.81 0.078 6-RC-1004-NSS-PRZ-1-N3-SE 2.000 3.11 28.50 31.61 13.17 0.081 6-RC-1009-NSS-1 2.000 2.93 28.50 31.43 13.10 0.080 6-RC-1009-NSS-2 2.000 3.36 28.50 31.86 13.27 0.081 6-RC-1009-NSS-3 2.000 2.09 28.50 30.59 12.75 0.078 6-RC-1009-NSS-4 2.000 2.36 28.50 30.86 12.86 0.079 6-RC-1009-NSS-5 2.000 2.97 28.50 31.47 13.11 0.080 6-RC-1009-NSS-6 2.000 3.42 28.50 31.92 13.30 0.081 6-RC-1009-NSS-7 2.000 3.08 28.50 31.58 13.16 0.080 6-RC-1009-NSS-8 2.000 2.83 28.50 31.33 13.06 0.080 6-RC-1009-NSS-9 2.000 2.01 28.50 30.51 12.71 0.078 6-RC-1009-NSS-PRZ-1-N4C-SE 2.000 2.95 28.50 31.45 13.10 0.080 6-RC-1012-NSS-1 2.000 2.99 28.50 31.49 13.12 0.080 6-RC-1012-NSS-2 2.000 3.35 28.50 31.85 13.27 0.081 6-RC-1012-NSS-3 2.000 3.08 28.50 31.58 13.16 0.080
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 1-Train (ft^3 per strainer)
Bed Thickness 1-Train (in) 6-RC-1012-NSS-4 2.000 2.79 28.50 31.29 13.04 0.080 6-RC-1012-NSS-5 2.000 3.56 28.50 32.06 13.36 0.082 6-RC-1012-NSS-6 2.000 3.59 28.50 32.09 13.37 0.082 6-RC-1012-NSS-7 2.000 3.36 28.50 31.86 13.28 0.081 6-RC-1012-NSS-8 2.000 3.53 28.50 32.03 13.35 0.082 6-RC-1012-NSS-9 2.000 4.15 28.50 32.65 13.60 0.083 6-RC-1012-NSS-10 2.000 3.69 28.50 32.19 13.41 0.082 6-RC-1012-NSS-11 2.000 3.46 28.50 31.96 13.32 0.081 6-RC-1012-NSS-PRZ-1-N4B-SE 2.000 2.99 28.50 31.49 13.12 0.080 6-RC-1015-NSS-1 2.000 3.49 28.50 31.99 13.33 0.081 6-RC-1015-NSS-2 2.000 3.71 28.50 32.21 13.42 0.082 6-RC-1015-NSS-3 2.000 3.90 28.50 32.40 13.50 0.083 6-RC-1015-NSS-4 2.000 3.98 28.50 32.48 13.53 0.083 6-RC-1015-NSS-5 2.000 3.91 28.50 32.41 13.51 0.083 6-RC-1015-NSS-6 2.000 3.56 28.50 32.06 13.36 0.082 6-RC-1015-NSS-7 2.000 3.20 28.50 31.70 13.21 0.081 6-RC-1015-NSS-8 2.000 3.19 28.50 31.69 13.21 0.081 6-RC-1015-NSS-9 2.000 2.78 28.50 31.28 13.03 0.080 6-RC-1015-NSS-10 2.000 2.34 28.50 30.84 12.85 0.079 6-RC-1015-NSS-11 2.000 1.45 28.50 29.95 12.48 0.076 6-RC-1015-NSS-12 2.000 1.49 28.50 29.99 12.49 0.076 6-RC-1015-NSS-13 2.000 1.43 28.50 29.93 12.47 0.076 6-RC-1015-NSS-14 2.000 1.57 28.50 30.07 12.53 0.077 6-RC-1015-NSS-15 2.000 1.50 28.50 30.00 12.50 0.076 6-SI-1108-BB1-1 2.000 0.32 28.50 28.82 12.01 0.073 6-SI-1108-BB1-2 2.000 0.36 28.50 28.86 12.02 0.073 6-SI-1108-BB1-3 2.000 0.38 28.50 28.88 12.03 0.074 6-SI-1108-BB1-4 2.000 1.13 28.50 29.63 12.35 0.075 6-SI-1111-BB1-1 2.000 0.66 28.50 29.16 12.15 0.074 6-SI-1111-BB1-2 2.000 0.74 28.50 29.24 12.18 0.074 6-SI-1208-BB1-1 2.000 0.31 28.50 28.81 12.00 0.073 6-SI-1208-BB1-2 2.000 0.34 28.50 28.84 12.02 0.073 6-SI-1208-BB1-3 2.000 0.38 28.50 28.88 12.03 0.074 6-SI-1208-BB1-4 2.000 0.52 28.50 29.02 12.09 0.074 6-SI-1211-BB1-1 2.000 0.46 28.50 28.96 12.07 0.074 6-SI-1211-BB1-2 2.000 0.56 28.50 29.06 12.11 0.074 6-SI-1308-BB1-1 2.000 0.68 28.50 29.18 12.16 0.074 6-SI-1308-BB1-2 2.000 0.68 28.50 29.18 12.16 0.074
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 1-Train (ft^3 per strainer)
Bed Thickness 1-Train (in) 6-SI-1308-BB1-3 2.000 0.64 28.50 29.14 12.14 0.074 6-SI-1308-BB1-4 2.000 0.79 28.50 29.29 12.20 0.075 6-SI-1327-BB1-1 2.000 0.60 28.50 29.10 12.12 0.074 6-SI-1327-BB1-2 2.000 0.93 28.50 29.43 12.26 0.075 6-SI-1327-BB1-3 2.000 1.00 28.50 29.50 12.29 0.075 6-SI-1327-BB1-4 2.000 0.81 28.50 29.31 12.21 0.075 6-SI-1327-BB1-5 2.000 1.05 28.50 29.55 12.31 0.075 6-SI-1327-BB1-6 2.000 1.04 28.50 29.54 12.31 0.075 6-SI-1327-BB1-7 2.000 1.26 28.50 29.76 12.40 0.076 8-RC-1114-BB1-1 2.000 0.99 28.50 29.49 12.29 0.075 8-RC-1114-BB1-2 2.000 1.19 28.50 29.69 12.37 0.076 8-RC-1114-BB1-3 2.000 1.32 28.50 29.82 12.43 0.076 8-RC-1114-BB1-4 2.000 1.38 28.50 29.88 12.45 0.076 8-RC-1114-BB1-5 2.000 1.66 28.50 30.16 12.57 0.077 8-RC-1114-BB1-6 2.000 2.07 28.50 30.57 12.74 0.078 8-RC-1214-BB1-1 2.000 1.21 28.50 29.71 12.38 0.076 8-RC-1214-BB1-2 2.000 1.24 28.50 29.74 12.39 0.076 8-RC-1214-BB1-3 2.000 1.33 28.50 29.83 12.43 0.076 8-RC-1214-BB1-4 2.000 1.25 28.50 29.75 12.40 0.076 8-RC-1214-BB1-5 2.000 1.68 28.50 30.18 12.57 0.077 8-RC-1214-BB1-6 2.000 2.11 28.50 30.61 12.75 0.078 8-RC-1324-BB1-1 2.000 1.20 28.50 29.70 12.38 0.076 8-RC-1324-BB1-2 2.000 1.35 28.50 29.85 12.44 0.076 8-RC-1324-BB1-3 2.000 1.47 28.50 29.97 12.49 0.076 8-RC-1324-BB1-4 2.000 1.41 28.50 29.91 12.46 0.076 8-RC-1324-BB1-5 2.000 1.63 28.50 30.13 12.56 0.077 8-RC-1324-BB1-6 2.000 1.96 28.50 30.46 12.69 0.078 8-RH-1108-BB1-1 2.000 0.31 28.50 28.81 12.00 0.073
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 1-Train (ft^3 per strainer)
Bed Thickness 1-Train (in) 8-RH-1108-BB1-2 2.000 0.62 28.50 29.12 12.13 0.074 8-RH-1112-BB1-1 2.000 0.35 28.50 28.85 12.02 0.073 8-RH-1112-BB1-1A 2.000 0.92 28.50 29.42 12.26 0.075 8-RH-1112-BB1-2 2.000 1.26 28.50 29.76 12.40 0.076 8-RH-1208-BB1-1 2.000 0.27 28.50 28.77 11.99 0.073 8-RH-1208-BB1-2 2.000 0.43 28.50 28.93 12.05 0.074 8-RH-1212-BB1-1 2.000 0.52 28.50 29.02 12.09 0.074 8-RH-1212-BB1-2 2.000 0.84 28.50 29.34 12.23 0.075 8-RH-1308-BB1-1 2.000 0.47 28.50 28.97 12.07 0.074 8-RH-1308-BB1-2 2.000 0.74 28.50 29.24 12.18 0.074 8-RH-1315-BB1-1 2.000 1.19 28.50 29.69 12.37 0.076 8-SI-1108-BB1-1 2.000 1.13 28.50 29.63 12.35 0.075 8-SI-1108-BB1-2 2.000 1.49 28.50 29.99 12.49 0.076 8-SI-1108-BB1-3 2.000 1.52 28.50 30.02 12.51 0.076 8-SI-1108-BB1-4 2.000 0.39 28.50 28.89 12.04 0.074 8-SI-1108-BB1-5 2.000 0.51 28.50 29.01 12.09 0.074 8-SI-1208-BB1-1 2.000 0.52 28.50 29.02 12.09 0.074 8-SI-1208-BB1-2 2.000 0.70 28.50 29.20 12.17 0.074 8-SI-1208-BB1-3 2.000 0.90 28.50 29.40 12.25 0.075 8-SI-1208-BB1-3A 2.000 0.60 28.50 29.10 12.12 0.074 8-SI-1208-BB1-4 2.000 0.92 28.50 29.42 12.26 0.075 8-SI-1327-BB1-1 2.000 1.38 28.50 29.88 12.45 0.076 8-SI-1327-BB1-2 2.000 1.38 28.50 29.88 12.45 0.076 8-SI-1327-BB1-3 2.000 1.36 28.50 29.86 12.44 0.076 8-SI-1327-BB1-4 2.000 1.04 28.50 29.54 12.31 0.075 8-SI-1327-BB1-5 2.000 0.84 28.50 29.34 12.22 0.075 8-SI-1327-BB1-6 2.000 0.85 28.50 29.35 12.23 0.075 8-SI-1327-BB1-7 2.000 0.78 28.50 29.28 12.20 0.075 8-SI-1327-BB1-8 2.000 0.77 28.50 29.27 12.20 0.075 8-SI-1327-BB1-9 2.000 0.66 28.50 29.16 12.15 0.074 8-SI-1327-BB1-10 2.000 0.77 28.50 29.27 12.19 0.075 8-SI-1327-BB1-11 2.000 0.64 28.50 29.14 12.14 0.074
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 1-Train (ft^3 per strainer)
Bed Thickness 1-Train (in) 10-RH-1108-BB1-1 2.000 0.62 28.50 29.12 12.13 0.074 10-RH-1108-BB1-1A 2.000 0.80 28.50 29.30 12.21 0.075 10-RH-1108-BB1-2 2.000 0.83 28.50 29.33 12.22 0.075 10-RH-1108-BB1-3 2.000 0.71 28.50 29.21 12.17 0.074 10-RH-1108-BB1-4 2.000 0.64 28.50 29.14 12.14 0.074 10-RH-1108-BB1-5 2.000 0.73 28.50 29.23 12.18 0.074 10-RH-1108-BB1-6 2.000 0.73 28.50 29.23 12.18 0.074 10-RH-1108-BB1-7 2.000 0.69 28.50 29.19 12.16 0.074 10-RH-1108-BB1-8 2.000 0.77 28.50 29.27 12.20 0.075 10-RH-1108-BB1-9 2.000 0.82 28.50 29.32 12.22 0.075 10-RH-1108-BB1-10 2.000 0.85 28.50 29.35 12.23 0.075 10-RH-1208-BB1-1 2.000 0.43 28.50 28.93 12.05 0.074 10-RH-1208-BB1-2 2.000 0.53 28.50 29.03 12.10 0.074 10-RH-1208-BB1-3 2.000 0.53 28.50 29.03 12.09 0.074 10-RH-1208-BB1-4 2.000 0.64 28.50 29.14 12.14 0.074 10-RH-1208-BB1-5 2.000 0.73 28.50 29.23 12.18 0.074 10-RH-1208-BB1-6 2.000 0.73 28.50 29.23 12.18 0.074 10-RH-1208-BB1-7 2.000 0.66 28.50 29.16 12.15 0.074 10-RH-1208-BB1-8 2.000 0.60 28.50 29.10 12.13 0.074 10-RH-1208-BB1-9 2.000 0.68 28.50 29.18 12.16 0.074 10-RH-1208-BB1-10 2.000 0.72 28.50 29.22 12.18 0.074 10-RH-1208-BB1-11 2.000 0.81 28.50 29.31 12.21 0.075 10-RH-1308-BB1-1 2.000 0.73 28.50 29.23 12.18 0.074 10-RH-1308-BB1-2 2.000 0.71 28.50 29.21 12.17 0.074
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 1-Train (ft^3 per strainer)
Bed Thickness 1-Train (in) 10-RH-1308-BB1-3 2.000 0.72 28.50 29.22 12.18 0.074 10-RH-1308-BB1-4 2.000 0.66 28.50 29.16 12.15 0.074 10-RH-1308-BB1-5 2.000 0.63 28.50 29.13 12.14 0.074 10-RH-1308-BB1-6 2.000 0.63 28.50 29.13 12.14 0.074 10-RH-1308-BB1-7 2.000 0.61 28.50 29.11 12.13 0.074 10-RH-1308-BB1-8 2.000 0.72 28.50 29.22 12.17 0.074 12-RC-1112-BB1-1 2.000 2.44 28.50 30.94 12.89 0.079 12-RC-1112-BB1-2 2.000 1.86 28.50 30.36 12.65 0.077 12-RC-1112-BB1-3 2.000 1.53 28.50 30.03 12.51 0.077 12-RC-1112-BB1-4 2.000 1.73 28.50 30.23 12.59 0.077 12-RC-1112-BB1-5 2.000 1.79 28.50 30.29 12.62 0.077 12-RC-1112-BB1-6 2.000 1.77 28.50 30.27 12.61 0.077 12-RC-1112-BB1-7 2.000 1.75 28.50 30.25 12.61 0.077 12-RC-1112-BB1-8 2.000 1.83 28.50 30.33 12.64 0.077 12-RC-1112-BB1-9 2.000 2.07 28.50 30.57 12.74 0.078 12-RC-1112-BB1-10 2.000 1.83 28.50 30.33 12.64 0.077 12-RC-1112-BB1-11 2.000 1.60 28.50 30.10 12.54 0.077 12-RC-1125-BB1-1 2.000 1.93 28.50 30.43 12.68 0.078 12-RC-1125-BB1-2 2.000 2.49 28.50 30.99 12.91 0.079 12-RC-1125-BB1-3 2.000 2.18 28.50 30.68 12.79 0.078 12-RC-1125-BB1-4 2.000 1.41 28.50 29.91 12.46 0.076 12-RC-1125-BB1-5 2.000 1.54 28.50 30.04 12.52 0.077 12-RC-1125-BB1-6 2.000 1.75 28.50 30.25 12.61 0.077 12-RC-1125-BB1-7 2.000 1.90 28.50 30.40 12.66 0.077
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 1-Train (ft^3 per strainer)
Bed Thickness 1-Train (in) 12-RC-1125-BB1-8 2.000 1.05 28.50 29.55 12.31 0.075 12-RC-1125-BB1-9 2.000 1.57 28.50 30.07 12.53 0.077 12-RC-1125-BB1-10 2.000 1.89 28.50 30.39 12.66 0.077 12-RC-1125-BB1-11 2.000 1.42 28.50 29.92 12.47 0.076 12-RC-1125-BB1-12 2.000 1.37 28.50 29.87 12.45 0.076 12-RC-1125-BB1-13 2.000 2.04 28.50 30.54 12.73 0.078 12-RC-1212-BB1-1 2.000 2.30 28.50 30.80 12.83 0.078 12-RC-1212-BB1-2 2.000 1.99 28.50 30.49 12.70 0.078 12-RC-1212-BB1-3 2.000 1.70 28.50 30.20 12.58 0.077 12-RC-1212-BB1-4 2.000 1.78 28.50 30.28 12.62 0.077 12-RC-1212-BB1-5 2.000 1.80 28.50 30.30 12.63 0.077 12-RC-1212-BB1-6 2.000 1.71 28.50 30.21 12.59 0.077 12-RC-1212-BB1-7 2.000 1.70 28.50 30.20 12.58 0.077 12-RC-1212-BB1-8 2.000 1.83 28.50 30.33 12.64 0.077 12-RC-1221-BB1-1 2.000 1.62 28.50 30.12 12.55 0.077 12-RC-1221-BB1-2 2.000 1.88 28.50 30.38 12.66 0.077 12-RC-1221-BB1-3 2.000 1.61 28.50 30.11 12.55 0.077 12-RC-1221-BB1-4 2.000 1.87 28.50 30.37 12.65 0.077 12-RC-1221-BB1-5 2.000 1.85 28.50 30.35 12.64 0.077 12-RC-1221-BB1-6 2.000 1.75 28.50 30.25 12.60 0.077 12-RC-1221-BB1-7 2.000 1.68 28.50 30.18 12.58 0.077 12-RC-1221-BB1-8 2.000 1.16 28.50 29.66 12.36 0.076 12-RC-1221-BB1-9 2.000 1.75 28.50 30.25 12.60 0.077 12-RC-1221-BB1-10 2.000 1.90 28.50 30.40 12.67 0.077
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 1-Train (ft^3 per strainer)
Bed Thickness 1-Train (in) 12-RC-1221-BB1-11 2.000 1.74 28.50 30.24 12.60 0.077 12-RC-1221-BB1-12 2.000 1.40 28.50 29.90 12.46 0.076 12-RC-1221-BB1-13 2.000 1.39 28.50 29.89 12.45 0.076 12-RC-1221-BB1-14 2.000 2.02 28.50 30.52 12.72 0.078 12-RC-1312-BB1-1 2.000 2.23 28.50 30.73 12.80 0.078 12-RC-1312-BB1-2 2.000 1.99 28.50 30.49 12.70 0.078 12-RC-1312-BB1-3 2.000 1.69 28.50 30.19 12.58 0.077 12-RC-1312-BB1-4 2.000 1.79 28.50 30.29 12.62 0.077 12-RC-1312-BB1-5 2.000 1.89 28.50 30.39 12.66 0.077 12-RC-1312-BB1-6 2.000 1.62 28.50 30.12 12.55 0.077 12-RC-1312-BB1-7 2.000 1.68 28.50 30.18 12.58 0.077 12-RC-1312-BB1-8 2.000 1.35 28.50 29.85 12.44 0.076 12-RC-1312-BB1-9 2.000 2.13 28.50 30.63 12.76 0.078 12-RC-1312-BB1-10 2.000 2.23 28.50 30.73 12.80 0.078 12-RC-1312-BB1-11 2.000 1.55 28.50 30.05 12.52 0.077 12-RC-1322-BB1-1 2.000 1.75 28.50 30.25 12.60 0.077 12-RC-1322-BB1-1A 2.000 1.08 28.50 29.58 12.33 0.075 12-RC-1322-BB1-2 2.000 1.35 28.50 29.85 12.44 0.076 12-RC-1322-BB1-3 2.000 1.34 28.50 29.84 12.43 0.076 12-RC-1322-BB1-4 2.000 1.95 28.50 30.45 12.69 0.078 12-RH-1101-BB1-1 2.000 1.34 28.50 29.84 12.43 0.076 12-RH-1101-BB1-2 2.000 0.68 28.50 29.18 12.16 0.074 12-RH-1101-BB1-3 2.000 0.70 28.50 29.20 12.16 0.074 12-RH-1101-BB1-3A 2.000 0.81 28.50 29.31 12.21 0.075
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 1-Train (ft^3 per strainer)
Bed Thickness 1-Train (in) 12-RH-1101-BB1-4 2.000 0.50 28.50 29.00 12.08 0.074 12-RH-1101-BB1-5 2.000 0.69 28.50 29.19 12.16 0.074 12-RH-1101-BB1-6 2.000 0.70 28.50 29.20 12.17 0.074 12-RH-1101-BB1-7 2.000 1.13 28.50 29.63 12.35 0.075 12-RH-1101-BB1-8 2.000 0.78 28.50 29.28 12.20 0.075 12-RH-1101-BB1-9 2.000 0.52 28.50 29.02 12.09 0.074 12-RH-1101-BB1-10 2.000 1.46 28.50 29.96 12.48 0.076 12-RH-1101-BB1-11 2.000 1.16 28.50 29.66 12.36 0.076 12-RH-1101-BB1-12 2.000 1.11 28.50 29.61 12.34 0.075 12-RH-1101-BB1-13 2.000 0.90 28.50 29.40 12.25 0.075 12-RH-1101-BB1-14 2.000 0.98 28.50 29.48 12.28 0.075 12-RH-1101-BB1-15 2.000 1.10 28.50 29.60 12.33 0.075 12-RH-1101-BB1-16 2.000 0.96 28.50 29.46 12.28 0.075 12-RH-1201-BB1-1 2.000 1.06 28.50 29.56 12.32 0.075 12-RH-1201-BB1-2 2.000 1.01 28.50 29.51 12.30 0.075 12-RH-1201-BB1-3 2.000 1.11 28.50 29.61 12.34 0.075 12-RH-1201-BB1-4 2.000 1.44 28.50 29.94 12.47 0.076 12-RH-1201-BB1-5 2.000 1.38 28.50 29.88 12.45 0.076 12-RH-1201-BB1-6 2.000 1.19 28.50 29.69 12.37 0.076 12-RH-1201-BB1-7 2.000 1.13 28.50 29.63 12.34 0.075 12-RH-1201-BB1-8 2.000 1.15 28.50 29.65 12.35 0.076 12-RH-1201-BB1-9 2.000 1.35 28.50 29.85 12.44 0.076 12-RH-1201-BB1-10 2.000 0.86 28.50 29.36 12.24 0.075 12-RH-1201-BB1-11 2.000 0.68 28.50 29.18 12.16 0.074
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 1-Train (ft^3 per strainer)
Bed Thickness 1-Train (in) 12-RH-1201-BB1-12 2.000 1.05 28.50 29.55 12.31 0.075 12-RH-1201-BB1-13 2.000 0.96 28.50 29.46 12.27 0.075 12-RH-1201-BB1-14 2.000 0.72 28.50 29.22 12.17 0.074 12-RH-1201-BB1-15 2.000 0.74 28.50 29.24 12.18 0.074 12-RH-1201-BB1-16 2.000 0.71 28.50 29.21 12.17 0.074 12-RH-1201-BB1-17 2.000 0.68 28.50 29.18 12.16 0.074 12-RH-1301-BB1-1 2.000 1.09 28.50 29.59 12.33 0.075 12-RH-1301-BB1-2 2.000 0.87 28.50 29.37 12.24 0.075 12-RH-1301-BB1-3 2.000 0.86 28.50 29.36 12.23 0.075 12-RH-1301-BB1-4 2.000 1.22 28.50 29.72 12.38 0.076 12-RH-1301-BB1-5 2.000 0.94 28.50 29.44 12.27 0.075 12-RH-1301-BB1-5A 2.000 0.73 28.50 29.23 12.18 0.074 12-RH-1301-BB1-6 2.000 0.84 28.50 29.34 12.23 0.075 12-RH-1301-BB1-7 2.000 0.81 28.50 29.31 12.21 0.075 12-RH-1301-BB1-8 2.000 0.72 28.50 29.22 12.17 0.074 12-RH-1301-BB1-9 2.000 0.71 28.50 29.21 12.17 0.074 12-RH-1301-BB1-10 2.000 0.67 28.50 29.17 12.15 0.074 12-SI-1125-BB1-1 2.000 0.65 28.50 29.15 12.15 0.074 12-SI-1125-BB1-2 2.000 0.89 28.50 29.39 12.25 0.075 12-SI-1125-BB1-3 2.000 1.09 28.50 29.59 12.33 0.075 12-SI-1125-BB1-4 2.000 1.18 28.50 29.68 12.37 0.076 12-SI-1218-BB1-1 2.000 0.68 28.50 29.18 12.16 0.074 12-SI-1218-BB1-2 2.000 0.97 28.50 29.47 12.28 0.075 12-SI-1218-BB1-3 2.000 0.98 28.50 29.48 12.28 0.075
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 1-Train (ft^3 per strainer)
Bed Thickness 1-Train (in) 12-SI-1218-BB1-4 2.000 0.98 28.50 29.48 12.28 0.075 12-SI-1315-BB1-1 2.000 0.41 28.50 28.91 12.04 0.074 12-SI-1315-BB1-2 2.000 0.76 28.50 29.26 12.19 0.075 12-SI-1315-BB1-3 2.000 0.92 28.50 29.42 12.26 0.075 12-SI-1315-BB1-4 2.000 0.97 28.50 29.47 12.28 0.075 12-SI-1315-BB1-5 2.000 0.93 28.50 29.43 12.26 0.075 12-SI-1315-BB1-6 2.000 0.49 28.50 28.99 12.08 0.074 12-SI-1315-BB1-7 2.000 0.56 28.50 29.06 12.11 0.074 12-SI-1315-BB1-8 2.000 1.50 28.50 30.00 12.50 0.076 12-SI-1315-BB1-9 2.000 1.83 28.50 30.33 12.64 0.077 12-SI-1315-BB1-10 2.000 2.18 28.50 30.68 12.78 0.078 16-RC-1412-NSS-1 2.000 1.13 28.50 29.63 12.35 0.075 16-RC-1412-NSS-3 2.000 2.16 28.50 30.66 12.78 0.078 16-RC-1412-NSS-4 2.000 2.19 28.50 30.69 12.79 0.078 16-RC-1412-NSS-5 2.000 1.77 28.50 30.27 12.61 0.077 16-RC-1412-NSS-6 2.000 2.29 28.50 30.79 12.83 0.078 16-RC-1412-NSS-7 2.000 2.61 28.50 31.11 12.96 0.079 16-RC-1412-NSS-8 2.000 1.98 28.50 30.48 12.70 0.078 16-RC-1412-NSS-9 2.000 2.90 28.50 31.40 13.08 0.080 16-RC-1412-NSS-PRZ-1-N1-SE 2.000 1.18 28.50 29.68 12.36 0.076 27.5-RC-1103-NSS-1 2.000 2.06 28.50 30.56 12.73 0.078 27.5-RC-1103-NSS-3 2.000 1.66 28.50 30.16 12.56 0.077 27.5-RC-1103-NSS-4 2.000 2.19 28.50 30.69 12.79 0.078 27.5-RC-1103-NSS-5 2.000 1.64 28.50 30.14 12.56 0.077
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 1-Train (ft^3 per strainer)
Bed Thickness 1-Train (in) 27.5-RC-1103-NSS-6 2.000 1.71 28.50 30.21 12.59 0.077 27.5-RC-1103-NSS-7 2.000 1.50 28.50 30.00 12.50 0.076 27.5-RC-1103-NSS-RPV1-N2ASE 2.000 1.03 28.50 29.53 12.30 0.075 27.5-RC-1203-NSS-1 2.000 1.79 28.50 30.29 12.62 0.077 27.5-RC-1203-NSS-3 2.000 2.58 28.50 31.08 12.95 0.079 27.5-RC-1203-NSS-4 2.000 1.70 28.50 30.20 12.59 0.077 27.5-RC-1203-NSS-5 2.000 1.09 28.50 29.59 12.33 0.075 27.5-RC-1203-NSS-RPV1-N2BSE 2.000 1.03 28.50 29.53 12.30 0.075 27.5-RC-1303-NSS-1 2.000 1.79 28.50 30.29 12.62 0.077 27.5-RC-1303-NSS-3 2.000 2.49 28.50 30.99 12.91 0.079 27.5-RC-1303-NSS-4 2.000 1.51 28.50 30.01 12.50 0.076 27.5-RC-1303-NSS-5 2.000 1.71 28.50 30.21 12.59 0.077 27.5-RC-1303-NSS-6 2.000 1.13 28.50 29.63 12.35 0.075 27.5-RC-1303-NSS-RPV1-N2CSE 2.000 1.03 28.50 29.53 12.30 0.075 27.5-RC-1403-NSS-1 2.000 1.90 28.50 30.40 12.67 0.077 27.5-RC-1403-NSS-3 2.000 1.98 28.50 30.48 12.70 0.078 27.5-RC-1403-NSS-4 2.000 1.84 28.50 30.34 12.64 0.077 27.5-RC-1403-NSS-5 2.000 1.71 28.50 30.21 12.59 0.077 27.5-RC-1403-NSS-6 2.000 1.08 28.50 29.58 12.32 0.075 27.5-RC-1403-NSS-RPV1-N2DSE 2.000 1.02 28.50 29.52 12.30 0.075 29-RC-1101-NSS-1 2.000 1.24 28.50 29.74 12.39 0.076 29-RC-1101-NSS-2 2.000 2.51 28.50 31.01 12.92 0.079
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 1-Train (ft^3 per strainer)
Bed Thickness 1-Train (in) 29-RC-1101-NSS-3 2.000 2.74 28.50 31.24 13.02 0.080 29-RC-1101-NSS-4 2.000 2.13 28.50 30.63 12.76 0.078 29-RC-1101-NSS-5.1 2.000 2.18 28.50 30.68 12.78 0.078 29-RC-1101-NSS-RPV1-N1ASE 2.000 0.98 28.50 29.48 12.28 0.075 29-RC-1101-NSS-RSG-1A-IN-SE 2.000 2.20 28.50 30.70 12.79 0.078 29-RC-1201-NSS-1 2.000 1.24 28.50 29.74 12.39 0.076 29-RC-1201-NSS-2 2.000 2.57 28.50 31.07 12.95 0.079 29-RC-1201-NSS-3 2.000 2.74 28.50 31.24 13.02 0.080 29-RC-1201-NSS-4 2.000 2.13 28.50 30.63 12.76 0.078 29-RC-1201-NSS-5.1 2.000 2.17 28.50 30.67 12.78 0.078 29-RC-1201-RPV1-N1BSE 2.000 0.98 28.50 29.48 12.28 0.075 29-RC-1201-RSG-1B-IN-SE 2.000 2.16 28.50 30.66 12.77 0.078 29-RC-1301-NSS-1 2.000 1.24 28.50 29.74 12.39 0.076 29-RC-1301-NSS-2 2.000 2.45 28.50 30.95 12.89 0.079 29-RC-1301-NSS-3 2.000 2.75 28.50 31.25 13.02 0.080 29-RC-1301-NSS-4 2.000 2.13 28.50 30.63 12.76 0.078 29-RC-1301-NSS-5.1 2.000 2.24 28.50 30.74 12.81 0.078 29-RC-1301-RPV1-N1CSE 2.000 0.98 28.50 29.48 12.28 0.075 29-RC-1301-RSG-1C-IN-SE 2.000 2.24 28.50 30.74 12.81 0.078 29-RC-1401-NSS-1 2.000 1.24 28.50 29.74 12.39 0.076 29-RC-1401-NSS-2 2.000 3.01 28.50 31.51 13.13 0.080 29-RC-1401-NSS-3 2.000 2.50 28.50 31.00 12.92 0.079 29-RC-1401-NSS-4.1 2.000 2.14 28.50 30.64 12.77 0.078 29-RC-1401-NSS-RPV1-N1DSE 2.000 0.98 28.50 29.48 12.28 0.075
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 1-Train (ft^3 per strainer)
Bed Thickness 1-Train (in) 29-RC-1401-NSS-RSG-1D-IN-SE 2.000 2.16 28.50 30.66 12.77 0.078 31-RC-1102-NSS-1.1 2.000 1.97 28.50 30.47 12.70 0.078 31-RC-1102-NSS-2 2.000 1.93 28.50 30.43 12.68 0.077 31-RC-1102-NSS-3 2.000 1.89 28.50 30.39 12.66 0.077 31-RC-1102-NSS-4 2.000 1.81 28.50 30.31 12.63 0.077 31-RC-1102-NSS-5 1.689 1.64 28.50 30.14 12.56 0.077 31-RC-1102-NSS-6 1.689 2.02 28.50 30.52 12.72 0.078 31-RC-1102-NSS-7 2.000 1.32 28.50 29.82 12.43 0.076 31-RC-1102-NSS-8 2.000 1.86 28.50 30.36 12.65 0.077 31-RC-1102-NSS-9 2.000 1.82 28.50 30.32 12.64 0.077 31-RC-1102-NSS-RSG-1A-ON-SE 2.000 1.97 28.50 30.47 12.70 0.078 31-RC-1202-NSS-1.1 2.000 2.00 28.50 30.50 12.71 0.078 31-RC-1202-NSS-2 2.000 1.93 28.50 30.43 12.68 0.077 31-RC-1202-NSS-3 2.000 1.89 28.50 30.39 12.66 0.077 31-RC-1202-NSS-4 2.000 1.82 28.50 30.32 12.63 0.077 31-RC-1202-NSS-5 1.689 1.65 28.50 30.15 12.56 0.077 31-RC-1202-NSS-6 2.000 1.35 28.50 29.85 12.44 0.076 31-RC-1202-NSS-7 1.689 1.97 28.50 30.47 12.70 0.078 31-RC-1202-NSS-8 2.000 1.85 28.50 30.35 12.65 0.077 31-RC-1202-NSS-9 2.000 1.83 28.50 30.33 12.64 0.077 31-RC-1202-NSS-RSG-1B-ON-SE 2.000 2.00 28.50 30.50 12.71 0.078 31-RC-1302-NSS-1.1 2.000 1.97 28.50 30.47 12.69 0.078 31-RC-1302-NSS-2 2.000 1.93 28.50 30.43 12.68 0.078 31-RC-1302-NSS-3 2.000 1.90 28.50 30.40 12.66 0.077
DRAFT Supplement to Follow up SSIB RAI 37 Location Break Size (in)
Max ZOI Fiber Trans (LBM)
Latent Fiber Trans (LBM)
Max Fiber Trans (LBM)
Transported Fiber Volume 1-Train (ft^3 per strainer)
Bed Thickness 1-Train (in) 31-RC-1302-NSS-4 2.000 1.82 28.50 30.32 12.64 0.077 31-RC-1302-NSS-5 1.689 1.68 28.50 30.18 12.57 0.077 31-RC-1302-NSS-6 2.000 1.29 28.50 29.79 12.41 0.076 31-RC-1302-NSS-7 2.000 1.73 28.50 30.23 12.60 0.077 31-RC-1302-NSS-8 2.000 1.92 28.50 30.42 12.67 0.077 31-RC-1302-NSS-9 2.000 1.82 28.50 30.32 12.63 0.077 31-RC-1302-NSS-RSG-1C-ON-SE 2.000 2.06 28.50 30.56 12.73 0.078 31-RC-1402-NSS-1.1 2.000 1.96 28.50 30.46 12.69 0.078 31-RC-1402-NSS-2 2.000 1.93 28.50 30.43 12.68 0.077 31-RC-1402-NSS-3 2.000 1.89 28.50 30.39 12.66 0.077 31-RC-1402-NSS-4 2.000 1.82 28.50 30.32 12.63 0.077 31-RC-1402-NSS-5 1.689 1.64 28.50 30.14 12.56 0.077 31-RC-1402-NSS-6 2.000 1.37 28.50 29.87 12.44 0.076 31-RC-1402-NSS-7 1.689 1.94 28.50 30.44 12.68 0.078 31-RC-1402-NSS-8 2.000 1.86 28.50 30.36 12.65 0.077 31-RC-1402-NSS-9 2.000 1.88 28.50 30.38 12.66 0.077 31-RC-1402-NSS-RSG-1D-ON-SE 2.000 1.96 28.50 30.46 12.69 0.078