1 NRR-PMDAPEm Resource From:

Richards, Drew <amrichards@STPEGS.COM>

Sent:

Tuesday, August 23, 2016 3:07 PM To:

Regner, Lisa Cc:

Harrison Albon

Subject:

[External_Sender] FW: PRA model information for NRC Attachments:

STP_REV81 CDF contributions.pdf; STP_REV81 LERF contributions.pdf Attached is the information regarding Level 1 and Level 2 Initiating Event contributions for the current PRA model (STP_REV81). And, here is the current CDF and LERF values:

CDF 7.86E-06 LERF 4.73E-07 Please forward to the Staff (C.J. and company) and contact us if you have any questions.

drew

Hearing Identifier:

NRR_PMDA Email Number:

3015 Mail Envelope Properties (a048ce89ea7345419788117ed2c39a45)

Subject:

[External_Sender] FW: PRA model information for NRC Sent Date:

8/23/2016 3:06:59 PM Received Date:

8/23/2016 3:07:05 PM From:

Richards, Drew Created By:

amrichards@STPEGS.COM Recipients:

"Harrison Albon" <awharrison@STPEGS.COM>

Tracking Status: None "Regner, Lisa" <Lisa.Regner@nrc.gov>

Tracking Status: None Post Office:

CMBXEXCH01.CORP.STPEGS.NET Files Size Date & Time MESSAGE 314 8/23/2016 3:07:05 PM STP_REV81 CDF contributions.pdf 27427 STP_REV81 LERF contributions.pdf 48535 Options Priority:

Standard Return Notification:

No Reply Requested:

Yes Sensitivity:

Normal Expiration Date:

Recipients Received:

Model: STP_RV81 STPEGS Probabilistic Risk Assessment Revision 8.1 Level 1 Quantification PRA-NB-41 Level 1 Results Rev 8.1.docx.1 14 Table 2 Initiating Event Contribution to CDF STP_RV81 INITIATOR IE_Freq CDF

%CDF CCDP External Events HWIND Tornado Induced Failure of Switchyard and ECP 1.22E-06 1.08E-06 13.72 8.84E-01 FR18 Control Room Fire Scenario 18 2.12E-06 8.30E-08 1.06 3.92E-02 Z047X Fire Zone 047 Scenario X 1.46E-05 3.58E-07 4.55 2.45E-02 FLECW ECW Failure Due to Breach of MCR 3.20E-07 2.83E-07 3.60 8.84E-01 Z071X Fire Zone 071 Scenario X 2.34E-07 2.07E-07 2.63 8.84E-01 Z047B Fire Zone 047 Scenario B 2.72E-03 1.60E-07 2.04 5.89E-05 Z47BC Fire Zone 047 Scenario BC 3.18E-06 6.24E-08 0.79 1.96E-02 SEIS3 Seismic Event, 0.4g Acceleration 7.74E-07 3.93E-08 0.50 5.08E-02 FR23 Control Room Fire Scenario 23 1.61E-06 2.29E-08 0.29 1.42E-02 SEIS4 Seismic Event, 0.6g Acceleration 6.14E-08 2.02E-08 0.26 3.29E-01 Z147O Fire Zone 147 Scenario O 1.08E-03 7.03E-09 0.09 6.51E-06 FL26 External Flooding Scenarios 2 Through 6 1.05E-08 9.23E-09 0.12 8.78E-01 SEIS2 Seismic Event, 0.2g Acceleration 2.89E-06 9.15E-09 0.12 3.17E-03 SEIS1 Seismic Event, 0.1g Acceleration 3.02E-05 1.74E-09 0.02 5.76E-05 FR10 Control Room Fire Scenario 10 3.43E-06 1.02E-09 0.01 2.98E-04 FL1 Flood Induced LOOP - Scenario 1 3.20E-06 9.93E-10 0.01 3.10E-04 Group Subtotal 3.87E-03 2.34E-06 29.81 Loss of Coolant Accidents ELOCA Excessive LOCA 3.54E-07 3.13E-07 3.97 8.83E-01 RCPL RCP Seal LOCA 2.36E-03 1.82E-07 2.32 7.72E-05 MLOCA Medium LOCA 4.90E-04 1.11E-07 1.41 2.26E-04 ILOCA Isolable Small LOCA 9.13E-04 4.26E-08 0.54 4.67E-05 SLOCA Non-Isolable Small LOCA 3.59E-04 2.09E-08 0.27 5.83E-05 LLOCA Large LOCA 1.34E-06 2.40E-08 0.31 1.80E-02 RCR2 2 or More RCS SRVs Open 1.02E-06 4.27E-11 0.00 4.20E-05 RCRV One RCS SRV Opens 1.45E-06 3.56E-11 0.00 2.46E-05 VSEQ Interfacing Systems LOCA 6.91E-12 4.91E-12 0.00 7.10E-01 Group Subtotal 4.13E-03 6.93E-07 8.81 Loss of Offsite Power Events LOOPG Loss of Offsite Power Grid Related 4.80E-03 6.36E-07 8.09 1.33E-04 LOOPP Loss of Offsite Power Plant Centered 8.57E-02 5.32E-08 0.68 6.21E-07

Model: STP_RV81 STPEGS Probabilistic Risk Assessment Revision 8.1 Level 1 Quantification PRA-NB-41 Level 1 Results Rev 8.1.docx.1 15 STP_RV81 INITIATOR IE_Freq CDF

%CDF CCDP LOOPS Loss of Offsite Power Switchyard Related 1.11E-02 1.39E-06 17.73 1.26E-04 LOOPW Loss of Offsite Power Weather Related 4.05E-03 6.39E-07 8.12 1.58E-04 Group Subtotal 1.06E-01 2.72E-06 34.62 Steam Generator Tube Rupture SGTR Steam Generator Tube Rupture 6.49E-03 5.51E-07 7.00 8.49E-05 Group Subtotal 6.49E-03 5.51E-07 7.00 Loss of Support Systems L1DCB Loss of DC Bus E1B11 8.29E-03 7.86E-08 1.00 9.48E-06 L1DCA Loss of DC Bus E1A11 8.29E-03 8.14E-08 1.04 9.82E-06 LOEAB3/6/9 Loss of EAB HVAC, BC/AB/ACRUN, All Support 2.74E-06 5.36E-08 0.68 1.96E-02 2.74E-06 2.79E-08 0.35 1.02E-02 2.74E-06 2.79E-08 0.35 1.02E-02 LOEAB2/5/8 Loss of EAB HVAC, BC/AB/ACRUN, HVAC A/C/B=F 4.07E-05 1.01E-08 0.13 2.47E-04 4.07E-05 1.01E-08 0.13 2.47E-04 4.07E-05 1.01E-08 0.13 2.47E-04 LOECW2/5/8 Loss of ECW, BC/AB/ACRUN, ECW A/C/B=F 6.10E-04 2.36E-08 0.30 3.87E-05 6.10E-04 2.36E-08 0.30 3.87E-05 6.10E-04 2.36E-08 0.30 3.87E-05 LOECW3/6/9 Loss of ECW, BC/AB/ACRUN, All Support 3.94E-06 2.83E-09 0.04 7.18E-04 3.94E-06 2.50E-09 0.03 6.34E-04 3.94E-06 2.50E-09 0.03 6.34E-04 LOCR3/6/9 Loss of CRE HVAC, BC/AB/ACRUN, All Support 1.38E-05 8.30E-09 0.11 6.04E-04 1.38E-05 8.04E-09 0.10 5.85E-04 1.38E-05 8.04E-09 0.10 5.85E-04 LOCR2/5/8 Loss of CRE HVAC, BC/AB/ACRUN, HVAC A/C/B=F 1.09E-04 1.54E-09 0.02 1.42E-05 1.09E-04 1.54E-09 0.02 1.42E-05 1.09E-04 1.54E-09 0.02 1.42E-05 LOCCW2/5/8 Loss of CCW, BC/AB/ACRUN, CCW A/C/B=F 1.84E-03 1.55E-10 0.00 8.39E-08 1.84E-03 1.91E-10 0.00 1.03E-07 1.84E-03 1.38E-10 0.00 7.51E-08 LOCCW3/6/9 Loss of CCW, BC/AB/ACRUN, All Support 5.50E-04 7.22E-10 0.01 1.31E-06 5.50E-04 5.67E-10 0.01 1.03E-06 5.50E-04 5.67E-10 0.01 1.03E-06 Group Subtotal 2.61E-02 4.10E-07 5.21

Model: STP_RV81 STPEGS Probabilistic Risk Assessment Revision 8.1 Level 1 Quantification PRA-NB-41 Level 1 Results Rev 8.1.docx.1 16 STP_RV81 INITIATOR IE_Freq CDF

%CDF CCDP General Transients SLBD Steam Line Break Outside Containment 8.58E-03 1.74E-07 2.21 2.03E-05 TTRIP Turbine Trip 4.24E-01 2.61E-07 3.31 6.14E-07 PLMFW Partial Loss of Main Feedwater 4.00E-01 2.46E-07 3.12 6.14E-07 RTRIP Reactor Trip 4.64E-01 2.81E-07 3.58 6.07E-07 LOPF Loss of Primary Flow 1.28E-01 7.81E-08 0.99 6.11E-07 SLBI Steam Line Break Inside Containment 9.31E-04 1.72E-08 0.22 1.85E-05 EXMFW Excessive Feedwater Flow 4.31E-02 2.59E-08 0.33 6.01E-07 IMSIV Closure of One MSIV 1.11E-02 6.55E-09 0.08 5.90E-07 TLMFW Total Loss of Main Feedwater 3.23E-02 1.94E-08 0.25 5.99E-07 LCV Loss of Condenser Vacuum 2.46E-02 1.47E-08 0.19 5.97E-07 SI Inadvertent Safety Injection 9.40E-03 5.75E-09 0.07 6.12E-07 AMSIV Closure of All MSIV's 1.02E-02 6.00E-09 0.08 5.88E-07 LOIA Loss of Instrument Air 5.47E-03 4.06E-09 0.05 7.42E-07 FLBO Feed Line Break in the IVC 3.26E-03 2.21E-09 0.03 6.79E-07 MSV MS Relief or Safety Valve Opening 3.85E-03 2.18E-09 0.03 5.67E-07 Group Subtotal 1.57E+00 1.14E-06 14.54 Total Reported Frequencies of the Group:

1.72E+00 7.86E-06 100.00

Model: STP_RV81 STPEGS Probabilistic Risk Assessment Revision 8.1 Level 2 Results PRA-NB-43 Level 2 Results Rev 8.1.docx 22 : Initiating Event Contributions to LERF Table Attachment 1: Initiating Event Contributions to LERF Initiator IE_Frequency Contribution CLERP HWIND2

1.22E06 1.16E07 9.52E02 LOOPS2

1.11E02 8.92E08 8.06E06 LOOPW2

4.05E03 4.09E08 1.01E05 LOOPG2

4.80E03 4.09E08 8.53E06 FLECW2

3.20E07 3.03E08 9.48E02 RTRIP2

1.46E05 1.82E08 1.25E03 Z047X2

8.58E03 1.76E08 2.05E06 TTRIP2

4.64E01 1.68E08 3.62E08 SLBDL2

4.24E01 1.53E08 3.61E08 PLMFW2

4.00E01 1.44E08 3.61E08 SGTRL2

6.49E03 8.66E09 1.33E06 Z047B2

2.36E03 7.59E09 3.21E06 RCPLL2

2.72E03 5.48E09 2.01E06 LOPFL2

2.12E06 4.91E09 2.32E03 FR18L2

1.28E01 4.52E09 3.53E08 Z071X2

2.34E07 4.34E09 1.85E02 LOOPP2

8.57E02 3.18E09 3.71E08 Z47BC2

3.18E06 3.06E09 9.61E04 L1DCA2

8.29E03 2.41E09 2.91E07 L1DCB2

2.74E06 2.25E09 8.22E04 LEB3L2

8.29E03 2.22E09 2.68E07 SEIS32

7.74E07 2.02E09 2.61E03 LEB6L2

2.74E06 1.92E09 7.01E04 LEB9L2

2.74E06 1.92E09 7.01E04 LEW5L2

6.10E04 1.55E09 2.53E06 LEW2L2

6.10E04 1.54E09 2.53E06 LEW8L2

6.10E04 1.54E09 2.53E06 EXMFW2

9.13E04 1.50E09 1.64E06 ILOCA2

4.31E02 1.47E09 3.40E08 TLMFW2

3.23E02 1.08E09 3.36E08 SLBIL2

9.31E04 1.02E09 1.10E06 LCVL2

1.05E08 9.69E10 9.22E02 FL26L2

6.14E08 8.81E10 1.44E02 SEIS42

2.46E02 8.11E10 3.29E08 LEB2L2

4.07E05 6.83E10 1.68E05 LEB5L2

4.07E05 6.83E10 1.68E05

Model: STP_RV81 STPEGS Probabilistic Risk Assessment Revision 8.1 Level 2 Results PRA-NB-43 Level 2 Results Rev 8.1.docx 23 LEB8L2

4.07E05 6.83E10 1.68E05 SIL2

9.40E03 5.06E10 5.38E08 SLOCA2

3.59E04 5.05E10 1.41E06 IMSIV2

1.11E02 3.50E10 3.15E08 AMSIV2

1.02E02 3.21E10 3.15E08 SEIS22

2.89E06 3.02E10 1.04E04 ELOCA2

3.54E07 2.84E10 8.03E04 FR23L2

1.61E06 2.79E10 1.73E04 LOIAL2

5.47E03 1.81E10 3.32E08 LEW3L2

1.38E05 1.67E10 1.21E05 LEW6L2

1.38E05 1.63E10 1.18E05 LEW9L2

1.38E05 1.63E10 1.18E05 LCR3L2

3.94E06 1.51E10 3.83E05 LCR6L2

3.94E06 1.48E10 3.76E05 LCR9L2

3.94E06 1.48E10 3.76E05 MSVL2

3.85E03 9.89E11 2.57E08 FLBOL2

3.20E06 6.66E11 2.08E05 FL1L2

3.26E03 5.88E11 1.81E08 Z147O2

1.09E04 3.02E11 2.78E07 LCR2L2

1.09E04 3.02E11 2.78E07 LCR5L2

1.09E04 3.02E11 2.78E07 LCR8L2

1.08E03 2.50E11 2.31E08 SEIS12

3.02E05 1.29E11 4.28E07 LLOCA2

1.34E06 1.20E11 9.00E06 FR10L2

3.43E06 1.15E11 3.35E06 LCC9L2

6.91E12 4.91E12 7.10E01 LCC3L2

5.50E04 4.25E12 7.72E09 LCC6L2

5.50E04 4.24E12 7.72E09 VSEQL2

5.50E04 4.24E12 7.71E09 LCC5L2

1.84E03 1.52E12 8.25E10 LCC2L2

1.84E03 0.00E+00 0.00E+00 LCC8L2

1.84E03 0.00E+00 0.00E+00 RCRVL2

1.45E06 0.00E+00 0.00E+00 MLOCA2

4.90E04 0.00E+00 0.00E+00 RCR2L2

1.02E06 0.00E+00 0.00E+00