UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Mr. Benjamin C. Waldrep Site Vice President Shearon Harris Nuclear Power Plant 5413 Shearon Harris Road M/C HNP01 New Hill, NC 27562-0165 August 23, 2016
SUBJECT:
SHEARON HARRIS NUCLEAR POWER PLANT, UNIT 1 - CORRECTION LETTER FOR AMENDMENTS 25 AND 120 TO THE RENEWED FACILITY OPERATING LICENSE
Dear Mr. Waldrep:
This letter corrects technical specification (TS) pages from two previously issued amendments.
On March 26, 1991, the U.S. Nuclear Regulatory Commission (NRC) issued Amendment No. 25 to Renewed Facility Operating License No. NPF-63 for the Shearon Harris Nuclear Power Plant, Unit 1 (Harris) (Agencywide Documents Access and Management System (ADAMS) Accession No. ML020580181 ). The amendment relocated certain numerical values for several cycle-specific core operating limits and restrictions from the Harris TSs to the existing Harris Core Operating Limits Report. The amendment number was included on pages 3/4 6-16 and 3/4 8-40, but the amendment number was inadvertently crossed out. This letter corrects Amendment 25 to clearly identify the amendment number on these pages.
On March 8, 2006, the NRC issued Amendment No. 120 to Facility Operating License No. NPF-63 for Harris (ADAMS Accession No. ML060580147). The amendment revised the footnotes in Tables 3.4-2 and 4.4-3 of TS 3/4.4.7 by increasing the temperature limit above which (1) reactor coolant sampling and analysis for dissolved oxygen is required, and (2) when limit for dissolved oxygen, specified in TS 4.4.7, applies. The amendment number was inadvertently left off of the TS amendment pages 3/4 4-27 and 3/4 4-28. This letter corrects Amendment 120 to include the amendment number on these pages.
The NRC staff concludes that the errors were introduced during the preparation of the license amendments and are entirely editorial in nature. The corrections do not change any of the conclusions in the safety evaluations associated with the amendments referenced above and do not affect the associated notices to the public. Enclosed, please find the corrected replacement pages.
If you have any questions regarding this matter, please call me at (301) 415-2760.
Docket No. 50-400
Enclosure:
Corrected Pages to Amendment No. 25 and Amendment No. 120 to NPF-63 cc w/encl: Distribution via Listserv Sincerely, Martha Barillas, Project Manager Plant Licensing Branch 11-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation
ENCLOSURE SHEARON HARRIS NUCLEAR POWER PLANT, UNIT 1 DOCKET NO. 50-400 CORRECTED PAGES TO LICENSE AMENDMENT NOS. 25 AND 120 RENEWED FACILITY OPERATING LICENSE NO. NPF-63
TABLE 3.4-2 REACTOR COOLANT SYSTEM CHEMISTRY LIMITS STEADY-STATE TRANSIENT PARAMETER LIMIT LIMIT Dissolved Oxygen.
- 0.10 ppm
- 1. 00 ppm Chloride
- 0.15 ppm
- 1.50 ppm Fluoride
- 0.15 ppm
- 1. 50 ppm
'Limit not applicable with Tavg less than or equal to 250°F.
SHEARON HARRIS - UNIT 1 3/4 4-27 Amendment No. 120
TABLE 4.4-3 REACTOR COOLANT SYSTEM CHEMISTRY LIMITS SURVEILLANCE REQUIREMENTS PARAMETER Dissolved Oxygen*
Chloride Fluoride SAMPLE AND ANALYSIS FREQUENCY At least once per 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> At least once per 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> At least once per 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />
'Not required with Tavg less than or equal to 250°F SHEARON HARRIS - UNIT 1 3/4 4-28 Amendment No. 120
TABLE 3.6-1 CONTAINMENT ISOLATION VALVES This table is deleted from Technical Specifications.
The information in this table is controlled by the Technical Specification Equipment List Program, plant procedure PLP-106.
PAGES 3/4 6-17 THROUGH 3/4 6-29 HAVE BEEN DELETED.
SHEARON HARRIS - UNIT 1 3/4 6-16 Amendment No. H, 25
TABLE 3.8-2 MOTOR-OPERATED VALVES THERMAL OVERLOAD PROTECTION This table is deleted from Technical Specifications.
The information in this table is controlled by the Technical Specification Equipment List Program, plant procedure PLP-106.
PAGES 3/4 8-41 THROUGH 3/4 8-43 HAVE BEEN DELETED.
SHEARON HARRIS - UNIT l 3/4 8-40 Amendment No.
l~, 25