8 to Updated Final Safety Analysis Report, Section 4.4, Figure 4.4-1 to Figure 4.4-21
ML16207A676
Person / Time
Site: South Texas  STP Nuclear Operating Company icon.png
Issue date: 04/28/2016
From:
South Texas
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16207A547 List: ... further results
References
NOC-AE-16003371
Download: ML16207A676 (19)


Text

UFSAR Section 4.4

"' 1-LL.

I a:

I 1.2

J 1-1.1 IIl -

X 1.0

...1 LL. 0.9 1-<

w 0.8 I

_J

<( 0.7

(.)

E a: 0.6

(.)

Cl 0.5 w

a: 0.4 en

<( 0.3 w

2 en 0.2

<(

w

~ 0.1 co 0.,...

0

........ u..

J:

(.)

~

0 0.1

+

+

~

,. 95% OF DATA WILL FALL ABOVE THIS LINE WITH 95% CONFJDENCE.

0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 (q"CHf/10 6

) PREDICTED CRITICAL HEAT FLUX (BTU/HR-FT2)

SOUTH TEXAS PROJECT UNITS 1 & 2 COMPARISON OF "RH GRID DATA FOR TYPICAL CELL (Reference (42])

Figure 4.4-1 Revision a

0 CX)

Cl.J Q)

II)

II) ra ra 0

~.c 0

0.. 0..

I r-*

N 0

~ ~

0 z

z:

Q --

z:

u u

&..I

~ -c c,:,

~ a..

0

&..I

"' en

~

OOQ)

~

10 10 NN 00 0

'2l 0

~

~ -

~

U'l I

0 --

0

~~j_

o6>

oo CD Q)

Q::

0 0

~

~

0 N

0 I

I I

I I

0 N

0 CCI

~

t" N

0 0

0 0

0 0

c:i 0

0 0

0 OOl SOUTH TEXAS PROJECT UNITS 1 &2 TDC VERSUS REYNOLDS NUMBER FOR 26" GRID SPACING Figure 4.4-4 Revision 0

I I

I.014-q_ -- 1.ooo-~~

--~

I I

-~-

--I""

KEY:

~ ~.. b.h/6h-'r--

G/G

~~:~ ~~DDDDD I

~~:~: ~C!J~DDDD

~.d96 ~~~.085 §-136. DO

.999 ~~

.999

.999

'"--+:-'

.--I:-+~~-~... ~II::~ Ill:: Ill:~~ II :

~6 1 D

.._1 :... ~-~--@D II:~~ Ill:~~ Ill::~ Ill:~~ I

.821 1.002

...__-+1---1

~

801

~659 1.002 1.002.

Definitions:

~h = Enthalpy Rise

~h = Average Enthalpy Rise G = Mass Flow Rate IG = Average Mass Flow Rate FOR RADIAL POWER DISTRIBUTION HEAR BEGINNING OF LIFE, HOT FULL POWER, EQUILIBRIUM XENON CALCULATED F~H = I.37 SOUTH TEXAS PROJECT UNITS 1 & 2 NORMALIZED RADIAL FLOW AND ENTHALPY DISTRIBUTION AT ELEVATION OF 1/3 OF CORE HEIGHT Unit 1 (Sheet 1 of 2}

Figure 4.4-5 Revision 0

I I

1.095

-r-0.999 __ _

KEY:

-f-ll.h/Ah ~r-G/G

--~

I I

FOR RADIAL POWER DISTRIBUTION NEAR BEGINNING OF LIFE, HOT FULL POWER, EQUILIBRIUM XENON CALCULATED F6H= 1.344 Definitions:

Ah = Enthalpy Rise b.h = Average Enthalpy Rise G = Mass Flow Rate G = Average Mass Flow Rate SOUTH TEXAS PROJECT UNITS 1 & 2 NORMALIZED RADIAL FLOW AND ENTHALPY DISTRIBUTION AT ELEVATION OF 1/3 OF CORE HEIGHT Unit 2 (Sheef2 of 2)

Figure 4.4-5 Revision 0

q_

I I

r.

I. 003

'l. --1.001 ---

J

--~

~

KEY:

fl.h/Ah---

G/G 1

-+~-:.... ~1~::~ 11~:~~ 11~:~~ IDD 1.1.36 EJL!]*228 ~9ijij ~882 EJ.OOI D
  • 995

. 958 I. 002 I. 007 I. 00 I

....._-+:--'

---.8+---.

1 73 ~~9()ij ~.083 ~912 ~621 I. 005 I. 00~

. 999 I. 00~

I. 0 I ~

I

.8 1

10 ~

~790 ~651 I. 008 I. 008 I. 0 13


+'--'

I FOR RADIAL POWER DISTRIBUTION NEAR BEGINNING OF LIFE, HOT FULL POWER, EQUILIBRIUM XENON CALCULATED F~H = 1.37 SOUTH TEXAS PROJECT UNITS 1 & 2 NORMALIZED RADIAL FLOW AND ENTHALPY DISTRIBUTION AT ELEVATION OF 213 OF CORE HEIGHT Unit 1 (Sheet 1 of 2)

Figure 4.4.. 6 Revision 0

I I

-~ 1.095 -!--

0.995 I

I t-KEY:

~~h/~h ~

G/G FOR RADIAL POWER DISTRIBUTION NEAR BEGINNING OF LIFE, HOT FULL POWER, EQUILIBRIUM XENON CALCULATED F Ll H= 1.344 1-Definitions:

~h = Enthalpy Rise

~h = Average Enthalpy Rise G = Mass Flow Rate G = Average Mass Flow Rate SOUTH TEXAS PROJECT UNITS 1 & 2 NORMALIZED RADIAL FLOW AND ENTHALPY DISTRIBUTION AT ELEVATION OF 213 OF CORE HEIGHT Unit 2 {Sheet 2 of 2)

Figure 4.4*6 Revision 0

I 1.002 q_

-~

1.000 I -

-~- -

KEY:

-r-6h/6h---

G/G 1.1.35 ~

~.228 ~94-5 ~803 ~998 D

.992

.986 1.003 1.013 1.001

...__..... !~

-+~-~- ~II:: II':~:~ Ill:~ I k~~ I

.80s ~

@!D789 ~651 I. 0 13 I. 0 I ~

I. 023 r

FOR RADIAL POWER D I STR I BUTI ON NEAR BEGINNING OF LIFE, HOT FULL POWER, EQUILIBRIUM XENON CALCULATED F~H = 1.37 SOUTH TEXAS PROJECT UNITS 1 & 2 NORMALIZED RADIAL FLOW AND ENTHALPY DISTRIBUTION AT CORE EXIT ELEVATION Unit 1 (Sheet 1 of 2)

Figure 4.4-7 Revision 0

I I

1.097

-- 0.993 f.-f.-

I I

r-KEY:

~h/~h-

~

GIG FOR RADIAL POWER DISTRIBUTION NEAR BEGINNING OF LIFE, HOT FULL POWER, EQUILIBRIUM XENON CALCULATED F~H= 1.344

-f--

Definitions:

~h = Enthalpy Rise

~h = Average Enthalpy Rise G = Mass Flow Rate G = Average Mass Flow Rate SOUTH TEXAS PROJECT UNITS 1 & 2 NORMALIZED RADIAL FLOW AND ENTHALPY DISTRIBUTION AT CORE EXIT ELEVAT10N unit 2 (Sheet 2 of 2)

Figure 4.4*7 Revision 0

lU01VH3dH31 MOIU'}JOUS S1'Y003 3~01Y~3dH31 Oln011 Ad1YH1M3 NO llY~OlTS S1V003 Ad1VH.1.M3 ll108 NOil~Y~,:j OIOA c.::l

~ =

0 CD

~

1 CD c.:l z _,

0 a:a _,

<C c.,)

0 _,

0

~ =

Q

Jt

~ - >-

(,j,_

0 -

.....J 01:: ~

CL.

z 0 -

~

~-

u z

01::

Q Cl..

... 0 -

c

.....J Q

ex U)

0

..... z

  • n
c I

0'

c --

V)

c I
c II I-z l.o.J 0

z l.o.J X ::

0

_, u a:a ""'

1-c.::l a:a *-

,_J l.o.J

1 w Q;

a:a Q

~

~.

c-u

~

z:

0 i 0:::

w l.o.J z

z::

1-CID X

z a:a ::z:

0

1

(,j a:a ""

c.::l 0

Q; z

Q SOUTH TEXAS PROJECT UNITS 1 & 2 VOID FRACTION VERSUS THERMODYNAMIC QUALITY H-HsAr/H9-HsAT Figure 4.4*8 Revision 0

0.07 I LFGENO:

PERCENT PERCENT

~

THEORETICAL THEORETICAL 0.06 1--

DENSITY OEN Sl TY 0 GYllANOER 96.4 0

HOWARD & GUlVIN 96.0 ASAHOfO 95.0 lUCKS A. OHM 96.5 0

Ui' 0

c..,

c:

tD J:

~

-m

-t

~.... g~

c:::J:

U;,

J:-t)>

Z-1 m)>,....

0 nn -m

~oo -t><

-i::oz en,_

~::oc me r-~g

~en om Ao"'O mo<

z.... -

1\\)~

~0~

-iiDo

0

~~.,.,

c..

tD

~c m

0 0

~:

IV 0

u 0.05 ~ -'e 0 GODFREY 93.4

() DANIEl ET AL.

96.5 0

fl. ~TORA 92.2 e,FEITH 97.9 E

u A. D.

BUSH 911.4 0

VOGT ET AL.

97.o 3

~

ASAHOTO 91.0 fj. ~ISHIJIHA 95.0

'J KRUGER 93.7 Y liHE£LER & AINSCOUGH 97.0 t--

~

It SEE REfERENCES FOR THE~Al-HYDRAULtC SECTION 0.~

+J *;

~*

+-'

u :s

~*o* *... *

-o 0.03 c

0 u

""1r~m*

10 0.02 L E

a""v o

QJ

~

A 0.01 0

400

. 800 I 200 1600 2000 TEMPERATURE (T). °C 2400 2800 3200

-1

~

0

.-----------------------------------------------~0 U1 +

...J 0 w U1 I

tn

+

...J 0

CD tn l

0 0

0 0

0 6

a 0

w 0

z t-4 ooo0 1o~

en 0

o o;;rt;co

(.)

J-U1 z

U1 w

u a:

w a..

~0 OJ-

-w IUl lL ll...

0 o';o

_J

<(

a:oo t-4 X

<(

0 N I

OilV~ 9NO ~n~INI~

SOUTH TEXAS PROJECT UNITS 1 & 2 100% POWER SHAPES EVALUATED AT CONDITIONS REPRESENTATIVE OF LOSS OF FLOW ALL SHAPES EVALUATEO WITH F~H = 1.52 Figure 4.4-10 Revision 0

u...

0.

...J co w

Cl)

Cl) 1-

<1 C/)

0 "V

c

~

-4

~

xJ c::t z

)>

~

Z-1 c

-m

~

~xI r-C/))>

Q

..a. en

xJ n c Ao"U r-

)>

0

-4

~0 0 z c..

xJ m

II)

~-

m 0

Vl lA

-i a*

-1

J 0

30 25 I 0

20 15 0.6 0.7 THINC II lEAST SQUARES fiT THINC I LEAST SQUARES FIT CLOSED CHlHHEL CONSTANT GIN 0.8 0

0.9 0

0 LEGEND:

0 MEASURED ASSEMBLY EXIT TEMPERATURE 1.0 1.1

  • ASSBMBLY POWER, BTU/HR X I0-6 1.2

Q

.. ***~

IZ 0

0'1

\\,6.1

a

'3 N

0 a..

z:

~

(,:,

~

0 0 0<30 [>

I I

I I

I 0

I N

t I

~

I 0

~

0:::

00

. z: --

~

-0 1.0 0

SOUTH TEXAS PROJECT UNITS 1 & 2 COMPARISON OF A REPRESENTATIVE W 2*LOOP REACTOR INCORE THERMOCOUPLE MEASUREMENTS WITH THINC*IV PREDICTIONS Figure 4.4*12 Revision 0

~I -

Q)

~......

~

a Q

M

~ CXI Q -

o..

ao ao ao

~ ~

zl ID.....

CXI en 0

~ C'f N

N N

C:i z:

~ OO<l Ot>

t:J

~

0 t><J 0

0

[J 0

<le 0

0 1-0 L.U N

....J

~~

a::

0 z:

a::

L.U

~

O')Q..

0~

cc

t L.U en en c:[

~~

o;::

c:[

....J L.U a=:

Q L.U

,....~

  • en 04:1 L.U U')

~------~------~------~~ 0 CD

~

N 0

Jo '(H'Jl.. d'Jl)

N I

03HnSV3W 'SA 3Hn!VH3dW3l 1IX3 A1SW3SSV 031JI03Hd SOUTH TEXAS PROJECT UNITS 1 & 2 COMPARISON OFA REPRESENTATIVE W 3-LOOP REACTOR I NCORE THERMOCOUPLE MEASUREMENTS WITH THINC-IV PREDICTIONS Figure 4.4*13 Revision 0

90 80 -

~

0 LU Cl')

a;:

£l.

e LU

~

~

0

I 0

cc:

LU D.

C1,. m RUN 143 70

~

LEGEND:

0 Q MEASURED

~THINC-IV 60 I

I 0

10 20 30 SUBCHAHi*t-L POWER DEHS I TY.

106 BTU/HR-FT3 SOUTH TEXAS PROJECT UNITS 1 & 2 HANFOROSUBCHANNELTEMPERATURE DATA COMPARJSON WITH THINC*IV Figure 4.4*14 Revision 0

~

u::a c.,

~

ol:ao

~ -

U\\

0 tD <

v;* a*

J 0

(/J o:z:

0

)>~

c:

~0

-1 n::o C:%

00 3:V'I z -1 zC:

m

"'Q c:u

_J

)>f'\\

o C!

en :a>

--i V'l-

~~

~ (/J

~ ~

Ao,

-im

-3:

..... ~

r"'Q IV' 0
i~

c...

z)>

m 0~

0

<~

-1 11&0 --------------------.....,

L4..

0 UJ (I) 120 a:: I 00 UJ o:=:

~

c(

a:::

UJ G..

~

...._ 80 fa a:::

~

(/)

c(

UJ

E 60 1&0 ij0

,' 6' 60 80 100 120 PREDICTED TEMPERATURE RISE, °F 11&0 PRESSURE 2014 PSIA HASS FLOW 0.5-2.2x 106LB /FT 2-HR ROO DIAMETER 0.422 INCHES ROO PITCH 0.555 INCHES HEATED LENGTH 84 INCHES HEAT FLUX DISTRIBUTION INNER ROD: OUTER ROO I. 204: 1.0 TC - THERMOCOUPLE LOCATION

0 T 0

TO T 0 T 0 T T

T 0

0 0

0 0 TO T

T 0 T T

T 0

0 0

0 TO TO T 0 T 0 T T

T 0 T

0 0

0 0

TO TO TO TO T 0 T 0 TO 0 T

0 0

0 0

T T

TO TO T

T 0 T

T 0

0 0

0 0

T T 0 T TO T

0 T 0

0 0

0 TO T

TO T 0 T 0 T 0

TO T = THERMOCOUPLE (50) 0 = MOVABLE INCORE DETECTOR (58 LOCATIONS)

SOUTH TEXAS PROJECT UNITS1&2 OISTRIBUT~ON OF INCORE INSTRUMENT AT ION Figure 4.4-20 Revision 0

630 620 610 600 G:

w 590 a:::

a:::

w 580 ll...

~

w t-570 560 550 540 0

20 592.6* F 560.3* F T COLD 40 60 80 100 PERCENT POWER SOUTH TEXAS PROJECT UNITS 1 & 2 REACTOR COOLANT SYSTEM TEMPERATURE PERCENT POWER MAP FIGURE 4. 4-21 REVISION 11 L1100.111