UFSAR Section 1 0.2

STEAM fROM BOllER

  • TKROITl£ VAlVE

\\

\\

GOVERlflKG *

  • VALVE t * *
  • ~
  • ~**.:. '

SPEED TRA~iS*

DUCtR 1---J_j_l_ -~~

t1

~ *,

REHEAT STOP t

F

'\\

~*

I P r. lP

  • .:,*_.. -:. ~---~

.. \\*.*..

~


~. -:*

Westinghouse ElECTRO* HYDRAULIC C0:1TROl SYSTEM fer Large Steam Turbine Generators

'\\ '

~ : * *

~**: 1..

" * * ~..

~....

~ -~.

.. *. \\

..... l.

~. _.,....~

lUBE Oil SUPPlY

... ~ ~I

.. ~.

11:0

~

J SOUTH TEXAS PROJECT UNITS 1 & 2 ELECTRO-HYDRAULIC CONTROL SYSTEM Figure 10.2-1 Revision 0

. ~

D EM 0 D U LA TOR

~4-~--*--------------------.

SERVO...

SERVO VALVE

- V AMPLIFIER s{f)~

DUMP VALVE ACTUATOR LVDT

.. ;. *.. :. *":~......

DR A Ill l.. :

~;.. :**.:,':<_;*~-: t ~t'i1~~i~i~~:ERNOR TRIP 1',

SOUTH TEXAS PROJECT UNITS 1 & 2 THROTTLE AND GOVERNOR VALVE ACTUATOR ASSEMBLY Figure 10.2-2 Revision 0

'"T1 c

m

<D G>i:

Om

-"" <::o 0

me>

. :um r\\) Z2 I

.a:a. on

u-<

-t>

U2
c cnl>

<c

~~

mr-

1:1

~:;

CD <

0

~*

c;*

2 0

EMERGENCY TRIP DEVICES MANUAL AND MECHANICAL OVERSPEED TRIP LJ OVERSPEED TRIP VALVE HP __._ _______

LUI. OIL rl en OVERSPEED 0

PROTECTION c

CONTROLLER

-1 c::t Z-t

-m

~><

en :a>

_.en RO, N:JJ 0

c.. m 0

~

PRESSURE SWITCH LJ LJ EMERGENCY TRIP VALVE EMERGENCY TRIP TO THROTTLE AND REHEAT STOP VALVES AUX. GOVERNOR TRIP TO GOVERNOR AND INTERCEPTOR VALVES

-n aa*

c: ; -

0 N

  • Ul en 0 c:

-1 c:::J:

Z-1

-m

-1><

en,..

~en Ao"'U N:U 0

~

m 0

-1 IRAISEIIL<r;tERI ~

I HOLol 11 I I I 11 OPERATOR'S REFERENCE CONTROLS SETTER COUNTER DISPLAY lOPER' CONTROL MODES 1[911 [gJJj II I I [] I ACCEL LOt~DJr\\G REFERENCE COUNTER DISPLAY RPM/MIN

.c-k/~1~

CONTINUOUS RAISE courrriNG AT LOWER S~LECTEO RATE UP I COUNT PER CLOSURE DOWN UP DIGITAL REFERENCE SYSTEM EVENT SETTER REF.

~UNTER COU~TER t~:~~~o--~~EN.BKR.CLOSURE "/o LOAD 0/o LOAD GEN.B:<R.OFENING 3600 RP~;;1 3500 R?r.t AliTOSTO? TRIP 0

0 REFERENCE RESETS

~.. REFERENCE COUNTER 1 $

  • READOUT-BCD

~

15 BITS

~f SPE~F LOAD REFERENCE

~

TURSINE SPEED...,__ __

~- L:*

I ~SPEED I Ofc ~----o-J

~-~-v~ ERROR -

o REGULATION TO TURBINE CuNTROLLER

YES YES TIME DELAY

.3-1.0 SEC.

TIME DELAY 1*10SEC.

TIME DELAY 10SEC NO YES NO YES YES PURCH. CIV INHIBJT CCO FAST VALVING DEMANDED ceo FOR FAST REOPEN-ING OF IV OIV XDUCER FAILURE INHIBIT RESET CIV FROM CIV LOGIC OIV RESET CIV FROM OPC LOGIC LEGEND:

OPC =- OVERSPEEO PROTECTION CONTROLLER CCI = CONTACT CLOSURE INPUT CCO = CONTACT CLOSURE OUTPUT CIV CIV YES OPC OPC CCO FAST VALVING EXECUTED ENERGIZE I. V.

SOL. VALVES

(

HYDR. CLOSE )

INTER. VALVES ENERGIZE OPC SOL.

(

HVDR. CLOSE)

GOV. & INTER.

VALVES SOUTH TEXAS PROJECT UNITS 1 & 2 OVERSPEED PROTECTION CONTROLLER Figure 10.2-6 Revision 0

STPEGS UFSAR UFSAR FIGURE 10.2-7 Reference Drawing(s) 7Tll9F20010#1 7Tll9F20010#2 Revision 5

STPEGS UFSAR UFSAR FIGURE 10.2-S Reference Drawing(s) 7T089FlOOOl#l 7T089Fl000l#2 Revision 5