Final Action Report/Improvement Plan, Exercise Date - May 17, 2016, Radiological Emergency Preparedness (REP) Program
ML16183A044
Person / Time
Site: Salem, Hope Creek  
Issue date: 06/28/2016
From: Tierney M
US Dept of Homeland Security, Federal Emergency Management Agency
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML16183A044 (107)


Text

JUN !Jj 2016 Nuclear Regulatory Commission Headquarters Office of Nuclear Security and Incident Response Document Control Desk U.S. Nuclear Regulatory Commission Washington, District of Columbia 20555-0001 To Whom It May Concern:

U.S. Department of Homeland Security Region III One Independence Mall, 6th Floor 615 Chestnut Street Philadelphia, PA 19106-4404 FEMA Enclosed is the final After Action Report/Improvement Plan for the Salem and Hope Creek Nuclear Generating Stations (SHCNGS) Plume Exercise held* on May 17, 2016.

There were no Level 1 Findings, Level 2 Findings, or Planning Issues identified during the drill.

Also, there were no outstanding Performance or Planning Issues from previous exercises.

Based on the results of the exercise and a review of the offsite radiological emergency response plans and procedures submitted, FEMA Region III has determined they are adequate (meet the planning and preparedness standards ofNUREG-0654/FEMA-REP-1, Revision 1, November 1980, as referenced in 44 CFR 350.5) and there is reasonable assurance they can be implemented, as demonstrated during this exercise.

If you have any questions, please contact Thomas Scardino at (215) 931-5 546.

Enclosure Mary Ann Tierney Regional Administrator www.fema.gov

Salem and. Hope Creek Nuclear Generating Station

. After Action Report/

Improvement Plan Exercise Date - May 17, 2016 Radiological Emergency Preparedness (REP) Program FE Published June 21, 2016

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station This page is intentionally blank.

2

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

  • Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Salem and Hope Creek Nuclec:tr Generating Station After Action Report/Improvement Plan Published June 21, 2016 EXECUTIVE

SUMMARY

.......................................................................................................... 5 SECTION 1: EXERCISE*OVERVIEW..................................................................................... 6 1.1 Exercise Details.................................................................................................................... 6 1.2 Exercise Planning Team Leadership................................................................................. 6 1.3 Participating Organizations.......................................... :.................................................... 8 SECTION 2: EXERCISE DESIGN

SUMMARY

.................................................................... 12 2.1 Exercise Purpose and Design *********************:***********************************************:..................... 12 2.2 Exercise Objectives, Capabilities and Activities............................................................. 15 2.3 Scenario Summary............................................................................................................ 15 SECTION 3: ANALYSIS OF CAPABILITIES.................................................. ~.................... 16 3.1 Exercise Evaluation and Results...................................................................................... 16 3.2 Summary Results of Exercise Evaluation....................................................................... 16 3.3 Criteria Evaluation Summaries....................................................................................... 20 3.3.l State Jurisdictions.................................................,........................................................ 20 3.3.2 Risk Jurisdictions.......................................................................................................... 22 3.3.3 Private Jurisdictions....................................................................................................... 25 SECTION 4: CONCLUSION.................................................................................................... 26 APPENDIX A: EXERCISE.TIMELINE.................................................................................. 27 APPENDIX B: EXERCISE EVALUATORS AND TEAM LEADERS................................ 29 APPENDIX C: ACRONYMS AND ABBREVIATIONS........................................................ 32 APPENDIX D: EXTENT OF PLAY AGREEMENT.............................................................. 36 3

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station This page is intentionally blank.

4

_J

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station EXECUTIVESU1\\1MARY On May 17, 2016, a full-scale Plume Exposure Pathway exercise was demonstrated and evaluated for the Delaware portion of the 10 Mile Emergency Planning Zone (EPZ) around the Salem and Hope Creek Generating Station (SHCNGS) by the Federal Emergency Management Agency (FEMA), Region III. The station is located in New Jersey, FEMA Region 2 evaluated the portion of the exercise conducted in New Jersey. The previous full-scale exercise at this site was evaluated on May 20, 2014.

Out-of-Sequence demonstrations were conducted on April 20th, 21st and May 6th, 2016. The purpose of the Exercise and Out-of-Sequence demonstrations was to assess the capabilities of State, counties, and local jurisdictions to implement Radiological Emergency Plans and Procedures (RERP) to protect the property and lives of residents and transients in the event of an emergency at SHCNGS. The findings in this report are based on the evaluations of the Federal evaluation team, with final determinations made by the FEMA, Region III Regional Assistance Committee (RAC) Chairperson, and approved by FEMA Headquarters. These reports are provided to the Nuclear Regulatory Commission (NRC) and participating states. State and local governments utilize the findings contained in these reports for the purposes of planning, training, and improving emergency preparedness.

The evaluation of this Exercise determined that there were no Level 1 or Level 2 findings. There were no Planning issues. There were no prior Performance and Planning Issues.

A Levell Finding is defined by the FEMA Radiological Emergency Preparedness.Program Manual as follows: "An observed or identified inadequacy of organizational performance in an exercise that could cause a determination that offsite emergency preparedness is not adequate to provide reasonable assurance that appropriate protective measures can be taken in the event of a radiological emerge11cy to protect the health and safety of the public living in the vicinity of a NPP.". A Level 2 Finding is defined as: "An observed or identified inadequacy of organizational performance in an exercise that is not considered, by itself, to adversely impact public health and safety." Finally, a Planning Issue is: "An observed or identified inadequacy in the ORO's emergency plan/implementing procedures, rather than that of the ORO's performance."

FEMA wishes to acknowledge the efforts of many individuals in the State of Delaware and the risk jurisdictions of Kent County and New Castle County. Protecting the public health and safety is the full-time job of some of the exercise participants and an additional assigned responsibility for others. Still others have willingly sought this responsibility by volunteering to provide vital emergency services to their communities. Cooperation and teamwork of all the participants was evident during the exercise.

5

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Action Report/Improvement Plan Radiological Emergency Preparedness Program (REP)

Salem and Hope Creek Nuclear Generating Station SECTION 1: EXERCISE OVERVIEW 1.1 Exercise Details Exercise Name Plume 2016-05-17 Type of Exercise Plume Exercise Date Marl 7, 2016 Program Department of Homeland Security/FEMA Radiological Emergency Preparedness Program Scenario Type Plume Exposure Pathway 1.2 Exercise Planning Team Leadership FEDERAL POC(s):

Marty Vyenielo Technological Hazards Specialist FEMA, Region III One Independence Mall 615 Chestnut Street 6th Floor Philadelphia PA 19106 Martin.Vyenielo@fema.dhs.gov (215) 931-5670 (w)

(215) 495-3624 (c) 6

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Salem and Hope Creek Nuclear Generating Station Action Report/Improvement Plan STATE POC(s):

Edward A. Lee {Tony)

Principal Planner Delaware Emergency Management Agency 165 Brick Store Landing Road Smyrna, DE 19977 Edward.Lee@state.de.us 302-659-2219 (w) 302-668-7884 (c)

Stephen F. Stasolla (Lead Controller)

Consultant stasolla@comcast.net 215-428-1017 (w) 267-994-6104 ( c) 7

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program *(HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station 1.3 Participating Organizations*

Agencies and organizations of the following jurisdictions participated in the Salem and Hope Creek Nuclear Generating Station exercise:

State Jurisdictions 1.3.1 State of Delaware 1.3.1.l State EOC Delaware Emergency Management Agency (DEMA)

Delaware National Guard (DNG)

Delaware Department of Agriculture (DDA)

Delaware Department of Transportation (DelDOT)

Delaware Department of Education (DOE)

Delaware Department of Correction (DOC)

Delaware Division of Energy Delaware Department of Health and Social Services (DHSS)

Delaware Division of Public Health (DPH)

Delaware Department of Natural Resources and Environmental Control (DNREC)

Delaware. Transit Corporation (DTC)

Delaware Volunteer Organizations Active in Disasters (DEVOAD)

Delaware State Police (DSP)

Delaware Division of Government Support Services (GSS)

U.S. Army Corps of Engineers (USACE)

U.S. Coast Guard (USCG)

Radio Amateur Civil Emergency Services (RACES)

DELMARVA Power

  • American Red Cross (ARC)

Delaware Division of Alcohol and Tobacco Enforcement (DATE)

Delaware Fire School (DFS) 1.3.1.2 Emergency New Center (Woodstown, NJ)

Delaware Emergency Management Agency Public Information Staff Delaware National Guard 8

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP}

Salem and Hope Creek Nuclear Generating Station Action Report!lmprovement Plan 1.3.1.3 State Technical Assessment Center (TAC)

Delaware Division of Public Health (DPH)

Delaware Department of Natural Resources and Environmental Control (DNREC)

Delaware Emergency Management Agency (DEMA)

Delaware National Guard (DNG)

Public Services Electric and Gas (PSE&G) 1.3.1.4 State Field Monitoring Team 1 Delaware National Guard

/

1.3.1.5 State Field Monitoring Team 2 Delaware National Guard 1.3.1.6 Traffic and Access Control Points (SEOC and parking lot)

Delaware State Police Delaware Department of Transportation 1.3.2 Risk Jurisdictions 1.3.2.1 Kent County EOC Kent County Levy Court Delaware State Police Kent County Department of Public Safety, Division of Emergency Management Dover Air Force Base (Observer)

American Red Cross Delaware Civil Air Patrol 1.3.2.2 New Castle County EOC New Castle County Office of Emergency Management New Castle County Division of Special Services New Castle County Division of Community Services Delaware Division of Public Health New Castle County Police Department New Castle County Department of Emergency Communications Christiana Area Radio Emergency Services/RACES New Castle County Emergency Medical Services 9

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Action Report/Improvement Plan Radiological Emergency Preparedness Program (REP) 1.3.3 Out of Sequence Exercise April 20, 2016 1.3.3.lAppoquinimink School District Appoquinimink School District 1.3.3.2 Alfred G. Waters Middle School

  • Advanced Student (Bus Company)

Salem and Hope Creek Nuclear Ge11erating Station Appoquinimink School District Transportation Director Alfred G. Waters Middle School Faculty 1.3.3.3 Transportation Dependent Evaluation (DART Wrangle Hill Road Facility)

Delaware Emergency Management Agency (DEMA)

Delaware Department of Transportation (DelDOT)

Delaware Transit Corporation (DTC),

New Castle County Emergency Management Agency 1.3.4 Out of Sequence Exercise April 21, 2016 1.3.4.1 Stern Readiness Reception Center Delaware National Guard Delaware Emergency Management Agency Delaware State Police Delaware Department of Health and Social Services Delaware Medical Reserve Corps (Lead Pharmacist)

Philadelphia College of Pharmacy American Red Cross 1.3.5 Out of Sequence Exercise May 6, 2016 MS-1 Christiana Hospital New Castle County Paramedics Delaware City EMS New Castle County Emergency Management Agency 1.3.6 Private Organizations Christiana Hospital Radio Amateur Civil Emergency Service (RACES) 10

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station SECTION 2: EXERCISE DESIGN

SUMMARY

2.1 Exercise Purpose and Design On December 7, 1979, the President directed the Federal Emergency Management Agency (FEMA) to assume the lead responsibility for all off-site nuclear planning and res:ponse. FEMA's activities were conducted pursuant to 44 Code of Federal Regulations (CFR) Parts 350, 351 and 352. These regulations are a key element in the Radiological Emergency Preparedness (REP)

Program that was established following the Three Mile Island Nuclear Station accident in March 1979.

44 CFR 350 establishes the policies and procedures for FEMA's initial and continued approval of State and local governments' radiological emergency planning and preparedness for commercial nuclear power plants. This approval is contingent, in part, on State and local government participation in joint exercises with licensees. FEMA's responsibilities in radiological emergency planning for fixed nuclear facilities include the following:

A. Taking the lead in offsite emergency planning and in the review and evaluation of Radiological Emergency Response Plans (RERPs) and procedures developed by State and local governments; B. Determining whether such plans and procedures can be implemented on the basis of observation and evaluation of exercises conducted by State and local governments; C. Responding to requests by the U.S. Nuclear Regulatory Commission (NRC) pursuant to the Memorandum of Understanding between the NRC and FEMA dated June 17, 1993 (Federal Register, Vol. 58, No. 176, September 14, 1993; and D. Coordinating the activities of the following Federal agencies with responsibilities in the radiological emergency planning process:

- U.S. Department of Commerce,

- U.S. Nuclear Regulatory Commission,

- U.S. Environmental Protection Agency,

- U.S. Department of Energy,

- U.S. Department of Health and Human Services,

- U.S. Department of Transportation,

- U.S. Department of Agriculture,

- U.S. Department of the Interior, and 11

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

U nclassifie*d Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station

- U.S. Food and Drug Administration Representatives of these agencies serve on the Region III Regional Assistance Committee (RAC), which is chaired by FEMA. A REP Plume Exposure Pathway Exercise was conducted during the week of May 16, 2016, to assess the capabilities of State and local emergency preparedness organizations in implementing their RERPs and procedures to protect the public health and safety during a radiological emergency involving Salem and Hope Creek Nuclear Generating Station (SHCNGS). The purpose of this exercise report is to present the exercise results and findings on the performance of the off-site response organizations (OROs) during a simulated radiological emergency. The findings presented in this report are based on the evaluations of the Federal evaluation team, with final determinations made by the FEMA Region III RAC Chairperson and approved by FEMA Headquarters.

These reports are provided to the NRC and participating States. State and local governments utilize the findings contained in these reports for the purposes of planning, training, and improving emergency response capabilities.

The criteria utilized in the FEMA evaluation process are contained in the following:

NUREG-0654/FEMA-REP-1, Rev. 1, "Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants, "November 1980; Radiological Emergency Preparedness Program Manual, January 2016;_

Section 1 of this report, entitled "Exercise Overview," presents the "Exercise Planning Team" and the "Participating Organization_s."

Section 2, of this report entitled "Exercise Design Summary", and includes the "Exercise Purpose and Design", "Exercise Objectives, Capabilities, and Activities", and the "Scenario Summary".

Section 3 of this report, entitled "Analysis of Capabilities, presents detailed "Exercise Evaluation and Results" information on the demonstration for each jurisdiction or functional entity evaluated in a jurisdiction-based, issue-only format (Criteria Evaluation Summaries). This section also contains:

The appendices, present supplementary information:

12

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Appendix A - Exercise Timeline. A table that depicts the times when an event or notifications were noted at participating agencies and locations.

Appendix B - Exercise Evaluators and Team leaders. A table listing the evaluator names, organizations, and responsibilities of the evaluators and management.

Appendix C - Acronyms and Abbreviations. An alphabetized table defining the formal names used in this report.

Appendix D - Method of Operation and Extent of Play Emergency Planning Zone

Description:

The SHCNGS site is located on the east bank of the Delaware River in Lower Alloways Creek Township, Salem County, New Jersey, about 20 miles south of Wilmington, Delaware. The 700-acre site is on the southern end of Artificial Island, a 3-mile-long, 1-mile-wide, man-made peninsula. The peninsula is connected to the mainland by a strip of tideland formed by hydraulic fill from dredging operations on the Delaware River. The tideland was constructed by the U.S.

Anny Corps of Engineers. The coordinates of the site are latitude 39°27'46" north and longitude 75°32'08" west. Two pressurized water reactors (Salem) and one boiling water reactor (Hope Creek) are located on the island. Each Salem unit generates a maxl.mum output of 1,106 megawatts (MW); Unit 1 commenced commercial operations in June 1977 and Unit 2 in October 1981. The Hope Creek Unit, which generates a maximum output of 1,031 MW, became operational in December 1986.

The site lies on the low coastal plain of New Jersey, surrounded by extensive marshlands and meadowlands. The land within the two Delaware counties (New Castle and Kent) near the site is either undeveloped ( 48 percent) or used for agricultural purposes ( 42 percent). Major farm products within a 25-mile radius of the site include vegetables, poultry, dairy products, and indigenous field crops.

The nearest major population center (more than 25,000 people) is Wilmington, Delaware, which has a population of71,529 and lies 20 miles north of S/HCNGS. The maximum population distribution in Delaware, including residents and transients, is 0 within the 2-mile EPZ, 850 within the 5-mile EPZ, and 24,976 within the 10-mile EPZ. There are 37 early warning sirens in the Delaware portion of the EPZ.

The Ingestion Planning Zone (IPZ) is approximately 7,850 square miles in area, which is equivalent to a 50-mile radius around the plant site. The States of Delaware, Maryland, and New Jersey, and the Commonwealth of Pennsylvania have jurisdictions within the IPZ. The largest city within the IPZ is Philadelphia, Pennsylvania, with a population of 1,526,006, about 46 miles from the plant site.

13

Radiological Emergency Preparedness (REP)/

Homeland S~curity Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station 2.2 Exercise Objectives, Capabilities and Activities The objective of the 2016 Salem and Hope Creek Nuclear Generating Station (SHCNGS) Plume Exercise was to demonstrate the capabilities of State and local emergency management agencies to mobilize emergency management and emergency response personnel, to activate emergency operations centers and support facilities, and to protect the health, lives, and property of the citizens residing within the 10 mile Emergency Planning Zone (EPZ).

To demonstrate the ability to communicate between multiple levels. of government and provide timely, a~curate, and sufficiently detailed information to the public, the emergency management agencies use a variety of resources, including radios, telephones, the Internet, the media, the Emergency Alert System (BAS), and the utility Alert and Notification System (ANS) Sirens. All of these communication resources were employed and evaluated. The BAS and ANS were simulated and media information was prepared but not actually released.

An essential capability of the Radiological Emergency Preparedness Program (REPP) is to evacuate, monitor and decontaminate, if necessary, and provide temporary care and shelter to displaced residents from the EPZ. The ability of the risk/support counties to mobilize personnel and resources to establish reception, monitoring and decontamination, and mass care centers was demonstrated.

The protection of school children is also a vital mission of the REPP. School districts and selected schools demonstrated the capability to communicate and coordinate the collection, evacuation, transportation and shelter of students attending schools within the EPZ.

2.3 Scenario Summary DHS/FEMA Region III, SALEM AND HOPE CREEK 2016 PLUME EXPOSURE PATHWAY EXERCISE-May 17, 2016 Exercise begins at 1600. All three reactors, Salem Unit 1, Salem Unit 2 and Hope Creek are operating at 100% power.

At 1605, an incident occurs at the Hope Creek reactor that results in a loss of coolant. An ALERT should be declared.

At 1830, a Site Area Emergency should be declared due to worsening conditions at the plant.

At 1935, the conditions worsen to the extent that a General Emergency is declared by the Emergency Coordinator at 1950 and a release ofradiation is expected.

14

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Action Report/Improvement Plan Radiological Emergency Preparedness Program (REP)

Salem and Hope Creek Nuclear Generating Station Wind conditions will drive any potential radioactive release toward the State of Delaware. State officials and off-site response organization will be expected to make appropriate protective action decision based on recommendations provided by the Utility.

At 2110, a wind occurs which pushes the radioactive release toward the State of New Jersey.

At approximately 2200 the release is stopped and at 2230 the exercise may be terminated.

15

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station SECTION 3: ANALYSIS OF CAP ABILITIES 3.1 Exercise Evaluation and Results Contained in this section are the results and findings of the evaluations of all jurisdictions and locations that participated in the May 17, 2016, biennial Plume Exposure Pathway EPZ Radiological Emergency Preparedness (REP) Exercise, and the Out of Sequence Exercise evaluations conducted on April 20th, April 21st and May 6th, 2016. The exercise was conducted to demonstrate the ability of the Off site Response Organizations of State and local government to protect the health and safety of the public in the 10 mile Emergency Planning Zone surrounding the Salem and Hope Creek Nuclear Generating Station.

Each jurisdiction and functional entity was evaluated on the basis of its demonstration of the Exercise Evaluation Area Criteria contained in the REP Exercise Evaluation Methodology.

Detailed information on the exercise evaluation area criteria is contained in this report.

3.2 Summary Results of Exercise Evaluation The matrix presented in Table 3.1, on the following pages, presents the status of the exercise evaluation area criteria from the REP Program Manual that was scheduled for demonstration during this exercise by all participating jurisdictions and functional entities. All evaluated criteria met the required demonstration(s). Exercise evaluation area criteria are li~ted by number and the demonstration status of the criteria is indicated by the use of the*following letters:

(D) Demonstrated Strength: an observed action, behavior, procedure, and/or practice that is worthy of special notice and positive recognition, Note: this is already a common practice that many Regions employ when identifying demonstrated strengths.

(Ll) Level 1 Finding: an-observed or identified inadequacy or organizational performance in an*

exercise that could cause a determination that offsite emergency preparedness is not adequate to provide reasonable assurance that appropriate protective measures can be taken in event of a radiological emergency to protect the health and safety of the public living in the vicinity of a Nuclear Power Plant (NPP).

(L2) Level 2 Finding: an observed or identified inadequacy of organizational performpnce in an exercise that is not considered, by itself, to adversely impact public health and safety.

(P) Plan Issue: an observed or identified inadequacy of organizational ill the offsite response organizations' (OROs) emergency plan/implementation procedures, rather than that of the ORO"s performance.

16

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Action Report/Improvement Plan Radiological Emergency Preparedness Program (REP)

Salem and Hope Creek Nnclear Generating Station (N) Not Demonstrated: term applied to the status of a REP exercise Evaluation Area Criterion indicating that the ORO, for a justifiable reason, did not demonstrate the Evaluation Area Criterion, as required in the extent-of-play agreement or at the two -year or eight-year interval required in the FEMA REP Program Manual.

(M) Met: status of a REP exercise Evaluation Area Criterion indicating that the participating ORO demonstrated all demonstration criteria for the Evaluation Area Criterion to the level required in the extent of-of-play agreement with no Findings assessed in the current exercise and no unresolved prior Findings.

17

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station ti'!if;i';:,¢',<t~~~~T;i c=.oc DEMAEOC DEMAEOC DEMAEOC DEMAEOC DEMAEOC DEMAEOC DEMAEOC DEMAEOC DEMAEOC DEMAEOC DEMAEOC SHCENC(NJ)

SHCENC(NJ)

DEEOCTAC DEEOCTAC DEEOCTAC DEEOCTAC DEEOCTAC DEEOCTAC DEEOCTAC SFMT# 1 SFMT# 1 SFMT# 1 SFMT# 1 SFMT# 1 SFMT#2 SFMT#2 SFMT#2 SFMT#2 SFMT#2 STAC/DELDOT/DSP STAC/DELDOT /DSP STAC/DELDOT/DSP STAC/DELDOT/DSP KCoEOC KCoEOC KCoEOC KCoEOC KCoEOC Tables 3.1 - Summary of Exercise Evaluation Table 3.1 - Exercise Evaluation - Criteria Met Date: 5/17/2016 Site: Salem and Hope Creek Nuclear Generating Station

  • ii":'.:'itt;;;i~~ *. (r\\;~J;~B;:;i./ *:zr,h" "*'**;;,~**r<

~-

  • :;,}_;,~>:;;**'<""- >',/'::~;_*;;.:o_.;.,,

":fi;:""'*"'**'*""" 'i:'E.J~2::*'*fli:< *. _,

Mobilization Direction and Control Communications Equipment and Supplies to Suooort Operations PAD decision-making process and coordination for the General Public P ADs for disabilities & access/functional needs people Implementation of PADs for disabilities & access/functional needs people Implementation of PADs for Schools Impediments to Evacuation Activation of the Prompt Alert & Notification System Emergency Information & Instructions for the Public/Media Mobilization Emergency Information & Instructions for the Public/Media Mobilization Direction and Control Communications Equipment and Supplies to Support Operations Emergency Worker Exposure Control Decisions Accident Assessment and P ARs for the Emergency Event Field Team Management

  • Mobilization Communications Equipment and Supplies to Support Operations Implementation of Emergency Worker Exposure Control Plume Phase Field Measurement, Handling, & Analyses Mobilization Communications Equipment and Supplies to Support Operations Implementation of Emergency Worker Exposure Control Plume Phase Field Measurement, Handling, & Analyses Communications Equipment and Supplies to Support Operations Implementation of Emergency Worker Exposure Control Implementation of Traffic & Access Control Mobilization Direction and Control Communications Equipment and Supplies to Support Operations Implementation of Emergency Worker Exposure Control 18

,.**.z +-,,;::'. *;><'<<**;.;;'/;ti~i{

lal lcl ldl lel 2b2 2cl 3cl 3c2 3d2 Sal Sbl lal Sbl lal lcl ldl lel 2al 2bl 4a2 lal ldl lel 3al 4a3 lal ldl lel 3al 4a3 ldl lel 3al 3dl lal lcl ldl lel 3al

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station KCoEOC Implementation of PADs for disabilities & access/functional needs people 3cl NCCEOC Mobilization lal NCCEOC Direction and Control lcl NCCEOC Communitations ldl NCCEOC Equipment and Supplies to Support Operations lel NCCEOC Implementation of Emergency Worker Exposure Control 3al NCCEOC Implementation of PADs for disabilities & access/functional needs people 3cl Locations evaluated Out of Sequence on April 20, 2016 ASDNCC Implementation of P ADs for Schools 3c2 NCCASAGWMS Implementation of P ADs for Schools 3c2 DARTWHRF Communications ldl DARTWHRF Equipment and Supplies to Support Operations lel DARTWHRF Implementation of Emergency Worker Exposure Control 3al DARTWHRF Implementation of PADs for disabilities & access/functional needs people 3cl Locations evaluated Out of Sequence on April 21, 2016 NCCRCSRCDNG Equipment and Supplies to Support Operations lel NCCRCSRCDNG Implementation of Emergency Worker Exposure Control 3al NCCRCSRCDNG Implementation of KI PAD for Institutionalized Individuals/Public 3bl NCCRCSRCDNG Reception Center Operations 6al Locations evaluated Out of Sequence on May 6, 2016 (MSl)

Christiana Hospital Equipment and Supplies to Support Operations lel Christiana Hospital Implementation of Emergency Worker Exposure Control 3al Christiana Hospital Transportation/Treatment of Contaminated Injured Individuals 6dl NCDCEMS Equipment and Supplies to Support Operations lel NCDCEMS Implementation of Emergency Worker Exposure Control 3al NCDCEMS Transportation/Treatment of Contaminated Injured Individuals 6dl 19

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station 3.3 Criteria Evaluation Summaries 3.3.1 State Jurisdictions 3.3.1.l State of Delaware Emergency Operations Center In summary, the status ofDHS/FEMA criteria for the State jurisdiction is as follows:

a. MET: I.a.I, l.c.I, l.d.I, Le.I, 2.b.2, 2.c.1, 3.c.1, 3.c.2, 3.d.2, 5.a.I,5.b.l
b. LEVEL I FINDINGS: NONE
c. LEVEL 2 FINDINGS: NONE
d. PLAN ISSUES: NONE
e. PRIOR ISSUES: RESOLVED: NONE
f.

PRIOR ISSUES: UNRESOLVED: NONE 3.3.1.2 Emergency News Center (Woodstown, NJ)

In summary, the status of DHS/FEMA criteria for the Delaware staff at this jurisdiction is as follows:

a. MET: I.a.I, 5.b.I
b. LEVEL I FINDINGS: NONE
c. LEVEL 2 FINDINGS: NONE
d. PLAN ISSUES: NONE
e. PRIOR ISSUES: RESOLVED: NONE
f.

PRIOR ISSUES: UNRESOLVED: NONE 3.3.1.3 Technical Assessment Center In summary, the status of DHS/FEMA criteria for the State jurisdiction is as follows:

a. MET: l.a.l, l.c.l, l.d.I, Le.I, 2.a.I, 2.b.1, 4.a.2 20

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Salem and Hope Creek Nuclear Generating Station Action Report/Improvement Plan

b. LEVEL 1 FINDINGS: NONE
c. LEVEL 2 FINDINGS: NONE
d. PLAN ISSUES: NONE
e. PRIOR ISSUES: RESOLVED: NONE
f.

PRIOR ISSUES: UNRESOLVED: NONE 3.3.1.4 State Field M(mitoring Team 1 In summary, the status of DHS/FEMA criteria for the State jurisdiction is as follows:

a. MET: l.a.l, l.d.1, l.e.l, 3.a.l, 4.a.3
b. LEVEL 1 FINDINGS: NONE
c. LEVEL 2 FINDINGS: NONE
d. PLAN ISSUES: NONE
e. PRIOR ISSUES: RESOLVED: NONE
f.

PRIOR ISSUES: UNRESOLVED: NONE 3.3.1.5 State Field Monitoring Team 2 In summary, the status ofDHS/FEMA criteria for the State jurisdiction is as follows:

a. MET: l.a.1, l.d.l, 1.e.l, 3.a.1, 4.a.3
b. LEVEL 1 FINDINGS: NONE
c. LEVEL 2 FINDINGS: NONE
d. PLAN ISSUES: NONE
e. PRIOR ISSUES - RESOLVED: NONE
f.

PRIOR ISSUES - UNRESOLVED: NONE 21

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Action Report/Improvement Plan Radiological Emergency Preparedness Program (REP)

Salem and Hope Creek Nuclear Generating Station 3.3.1.6 Traffic and Access Control (SEOC.and parking lot)

In summary, the status ofDHS/FEMA criteria for the State jurisdiction is as follows:

a. MET: l.d.l, l.e.l, 3.a.l, 3.d.l
b. LEVEL 1 FINDINGS: NONE
c. LEVEL 2 FINDINGS: NONE
d. PLANISSUES: NONE
e. PRIOR ISSUES - RESOLVED: NONE
f.

PRIOR ISSUES - UNRESOLVED: NONE 3.3.2 Risk Jurisdictions 3.3.2.1 Kent County Emergency Operations Center In summary, the status ofDHS/FEMA criteria for this Risk location is as follows:

a. MET: l.a.1, l.c.l, l.d.l, l.e.l, 3.a.l, 3.c.1
b. LEVEL 1 FINDINGS: NONE
c. LEVEL 2 FINDINGS: NONE
d. PLAN ISSUES: NONE
e. PRJOR ISSUES: RESOLVED: NONE
f.

PRJOR ISSUES: UNRESOLVED: NONE 3.3.2.2 New Castle County Emergency Operations Center In summary, the status ofDHS/FEMA criteria for this Risk location is as follows:

a. MET: l.a.l, l.c.l, l.d.l, l.e.1, 3.a.l, 3.c.1
b. LEVEL 1 FINDINGS: NONE
c. LEVEL 2 FINDINGS: NONE 22

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Salem and Hope Creek Nuclear Generating Station Action Report!Improvement Plan

d. PLAN ISSUES: NONE
e. PRJOR ISSUES: RESOLVED: NONE
f.

PRJOR ISSUES: UNRESOLVED: NONE 3.3.2.3 New Castle County Appoquinimink School District In summary, the st~tus ofDHS/FEMA criteria for this Risk location is as follows:

a. MET: 3.c.2
b. LEVEL 1 FINDINGS: NONE
c. LEVEL 2 FINDINGS: NONE
d. PLAN ISSUES: NONE
e. PRJOR ISSUES: RESOLVED: NONE
f.

PRJOR ISSUES: UNRESOLVED: NONE 3.3.2.4 New Castle County Alfred G. Waters Middle School In summary, the status ofDHS/FEMA criteria for this Risk location is as follows:

a. MET: 3.c.2
b. LEVEL 1 FINDINGS: NONE
c. LEvEL 2 FINDINGS: NONE
d. PLAN ISSUES: NONE
e. PRJOR ISSUES: RESOLVED: NONE
f.

PRJOR ISSUES: UNRESOLVED: NONE 3.3.2.5 Transportation Dependent evaluation at DART-New Castle County In summary, the status ofDHS/FEMA criteria for this Risk location is as follows:

a. MET: l.d.1, l.e.1, 3.a.1, 3.c.l 23

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Action Report/Improvement Plan Radiological Emergency Preparedness Program (REP)

Salem and Hope Creek Nuclear Generating Station

b. LEVEL I FINDINGS: NONE
c. LEVEL 2 FINDINGS: NONE
d. PLAN ISSUES: NONE
e. PRIOR ISSUES: RESOLVED: NONE
f.

PRIOR ISSUES: UNRESOLVED: NONE 3.3.2.6 New Castle County Stern Readiness Reception Center In summary, the status of DHS/FEMA criteria for this Risk location is as follows:

a. MET: l.a.1, 3.a.l, 3.b.l, 6.a.l
b. LEVEL I FINDINGS: NONE
c. LEVEL 2 FINDINGS: NONE
d. PLAN-ISSUES: NONE
e. PRIOR ISSUES: RESOLVED: NONE
f.

PRIOR ISSUES: UNRESOLVED: NONE 3.3.2.7 New Castle County, Delaware City EMS, MS-1 Drill In summary, the status of DHS/FEMA criteria for this Risk location is as follows:

a. MET: Le.I, 3.a.l, 6.d.l
b. LEVEL 1 FINDINGS: NONE
c. LEVEL 2 FINDINGS: NONE
d. PLAN ISSUES: NONE
e. PRIOR ISSUES: RESOLVED: NONE
f.

PRIOR ISSUES: UNRESOLVED: NONE 24

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Salem and Hope Creek Nuclear Generating Station Action Report/Improvement Plan 3.3.3 Private Jurisdictions 3.3.3.l Christiana Hospital MS-1 In summary, the status ofDHS/FEMA criteria for the Private jurisdiction is as follows:

a. MET: l.e.l, 3.a.l, 6.d.l
b. LEVEL 1 FINDINGS: NONE
c. LEVEL 2 FINDINGS: NONE
d. PLAN ISSUES: NONE
e. PRIOR ISSUES: RESOLVED: NONE
f.

PRIOR ISSUES: UNRESOLVED: NONE 25

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station SECTION 4: CONCLUSION The State of Delaware and local jurisdictions, except where noted in this report demonstrated*

knowledge of their Radiological Emergency Response Plans (RERP) and procedures were adequately implemented during the Salem and Hope Creek Nuclear Generating Station Plume exercise evaluated on May 17, 2016.

Federal Emergency Management Agency (FEMA) evaluators provided analyses of sixty-two evaluation criteria. These analyses resulted in a determination of no Level 1 Findings, Level 2 Findings, or New Plan Issues.

"Based on the results of the exercise and a review of the offsite radiological emergency response plans and procedures submitted, FEMA Region Ill has determined they are adequate (meet the planning and preparedness standards ofNUREG-0654/FEMA-REP-1, Revision 1, November 1980, as referenced in 44 CFR 350.5) and there is reasonable assurance they can be implemented, as demonstrated during this exercise."

An After Action Implementation Plan (IP) will not be developed as part of this report.

26

Radiological Emergency Preparedn<=ss (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station APPENDIX A: EXERCISE TIMELINE This section contains the Exercise Timeline. A table that depicts the times when an event or notifications were noted at participating agencies and locations.

ECL Timeline Table: May 17, 2016 Salem and Hope Creek Nuclear Generating Station Alert 1612 SAE 1829 GE 2001 Start of Simulated 1938 Radiation Release Termination of Simulated Radiation N/A Release Facili Declared 0 erational Governor's Declaration of State of Erner enc Exercise Terminated First Protective Action Decision Describe:

Evacuate ERPA "A" Evacuate School and Special Populations, 0-5 miles Place animals on stored feed and covered water, conduct river alerting ERP AD, ERP A C prepare and monitor.

Siren Sounding EAS Broadcast time Additional Precautionary Actions Describe:

Second Protective Action Decision Describe:

Monitor/prep ERP AB Siren Sounding Delaware SEOC 1626 1841 2013 1944 2215 1645 1912 2237 1916 1925 1930 N/A 2040 2105 Delaware TAC 1626 1841 2013 1944 2215 1706 1912 2237 1920 1925 1930 N/A 2053 2105 27 Emergency News Center Woodstown, NJ N/A 1829 2005 2005 2215 1757 1950 2237 1939 1925 1930 N/A 2100 2105 Kent County 1642 1845 2014 2001 2215 1650 1914 2237 1916 1925 1930 N/A 2040 2105 New Castle County 1639 1847 2017 2000 2215 1700 1915 2237 1916 1925 1930 NIA 2040 2105

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Progra*m (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station EAS Message Broadcast 2110 2110 2110 2110 2110 KI Decision - NO 2040 2040 2040 2040 2040 Emergency Workers KI Decision - NO 2040 2040 2040 2040 2040 General Public 28 I

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station APPENDIX B: EXERCISE EVALUATORS AND

. TEAMLEADERS The following is the list of Evaluators and Team Leaders for the Salem and Hope Creek Nuclear Generating Station 2016 Radiological Emergency Preparedness Plume Exercise evaluated on May 17, 2016. The following constitutes the managing staff for the Exercise Evaluation:

  • Thomas Scardino, DHS/FEMA, Regional Assistance Committee (RAC) Chairman
  • Martin Vyenielo, DHS/FEMA, Project Officer and Site Specialist DATE: 5/17/2016 SITE: Salem and Hope Creek Nuclear Generating Station
  • 10~{~{\\;

,,,.~""" ;~1~'.,'.{:~¥fi1¥'le'fi;>.~':;n1.1.11:1k'~!,'.~~;.~~f ;10'&J;;~iY:\\~~,,f!~Cft :~;f~pl~~~p::~:~'§~:§~['.f~~~~~f-1~il{}ift~~~~~~

Delaware State Emergency Operations Center Barton Freeman FEMA Region 3 Emergency News Center (Woodstown, NJ)

Barton Freeman FEMA Region 3 Traffic and Access Control Points Barton Freeman FEMA Region 3 Delaware State Technical Assessment Center Michael Shuler FEMA Region 3 State Field Monitoring Team 1 Michael Shuler FEMA Region 3 State Field Monitoring Team 2 Michael Shuler FEMA Region 3 Traffic and Access Control Points Barton Freeman FEMA Region 3 Kent County Emergency Operations Center John Price FEMA Region 3 New Castle County Emergency Operations Center William McDougall FEMA Region 3 Out of Sequence Exercise April 20, 2016 Appoquinimink School District Martin Vyenielo FEMA Region 3 Alfred G. Waters Middle School Martin Vyenielo FEMA Region 3 Transportation Dependent Evaluation (DART)

  • Martin Vyenielo FEMA Region 3 Out of Sequence Exercise April 21, 2016 Stem Readiness Center Reception Center Martin Vyenielo FEMA Region 3 Out of Sequence Exercise May 6, 2016 MS-1 Christiana Hospital Joseph Suders FEMA Region 3 Delaware City EMS, New Castle Paramedics Martin Vyenielo FEMA Region 3 Delaware State Emergency Operations Center Barton Freeman FEMA Region 3 29

F3-adiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Delaware State Emergency Operations Center Tina Lai-Thomas FEMA Region 3 Delaware State Emergency Operations Center Lee Torres FEMA Region 3 Delaware State Emergency Operations Center Joseph Suders FEMA Region 3 Emergency News Center (Woodstown, NJ)

Thomas Murray FEMA Region 3 Delaware Technical Assessment Center Michael Shuler FEMA Region 3 Delaware Technical Assessment Center Johanna Johnson FEMA Region 9 State Field Monitoring Team 1 Larry Broockered FEMAHQ Tim Pflieger FEMA Region 6 State Field Monitoring Team 2 Christine Schullingkamp (OJT)

EPA Traffic and Access Control Points Kerry Holmes FEMA Region 3 Kent County Emergency Operations Center JohnBrasko FEMA Region 3 Kent County Emergency Operations Center Kathy Duran FEMA Region 3 Kent County Emergency Operations Center John Price FEMA Region 3 New Castle County Emergency Operations Center Brad DeKorte FEMA Region 6 New Castle County Emergency Operations Center William McDougall FEMA Region 3 Nick Buls (OJT)

FEMA Region 3 New Castle County Emergency Operations Center Rufus Mobley FEMAHQ Out Of Sequence Exercise April 20, 2016 Appoquinimink School District Martin Vyenielo FEMA Region 3 Alfred G. Waters Middle School Michael Shuler FEMA Region 3 Nick Buls (OJT)

FEMA Region 3 Transportation Dependent Evaluation (DART)

Michael Shuler FEMA Region 3 Nick Buls (OJT)

FEMA Region 3 Out of Sequence Exercise April 21, 2016 Stem Readiness Center Reception Center Michael Shuler FEMA Region 3 Martin Vyenielo FEMA Region 3 30

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Nick Buis (OJT)

FEMA Region 3 Out of Sequence Exercise May 6, 2016 MS-1 Christiana Hospital Joseph Suders FEMA Region 3 Nick Buls (OJT)

FEMA Region 3 Delaware City EMS and New Castle Paramedics Martin Vyenielo FEMA Region 3 31

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station APPENDIX C: ACRONYMS AND ABBREVIATIONS Acronym Description ACP Access Control Point ALARA As Low As Reasonably Achievable ARC American Red Cross ARES Amateur Radio Emergency Services ASD Appoquinimink School District BURA Back Up Route Alerting CAD Computer Aided Display CDE Committed Dose Equivalent CERC Corporate Emergency Response Center CERT Community Emergency Response Team co Communication Officer CPM Counts Per Minute CST Civil Support Team DAC Dose Assessment Coordinator DAD Digital Alarming Dosimetry DARTWHRF Delaware Area Rapid Transit Wrangle Hill Road Facility DAS Director of Auxiliary Services DDHS Department of Health and Human Services DEEOCTAC Technical Assessment Center at State ~QC DEMAEOC Delaware Emergency Management Agency EOC DOT Department of Transportation DRF Dosimetry Record Form EAL Emergency Action Level EARA Exception Area Route Alerting EAS Emergency Alert System EC Emergency Coordinator ECL Emergency Classification Level ECO Exposure Control Officer EMC Emergency Management Coordinator EMD Emergency Management Director.

EMnet Emergency Management Network EMS Emergency Medical Services EOC Emergency Operations Center EOF Emergency Operations Facility EOP Extent of Play 32

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station EPA Environmental Protection Agency EPT Exercise Planning Team EPZ Emergency Planning Zone ER Emergency Room ERM Emergency Response Manager ERV Emergency Response Vehicle ESC Emergency Services Coordinator ESP Emergency Support Function ETA Estimated Time of Arrival EW Emergency Workers FD Fire Department FEMA Federal Emergency Management Agency FMT Field Monitoring Team FRMAC Federal Radiological Monitoring Assessment Center FSE Full Scale Exercise FTC Field Team Coordinator GE General Emergency GIS Geographic Information Systems GPS Global Positioning System HAN Health Alert Network HazMat Hazardous Materials HF.

High Frequency HSEEP Homeland Security Exercise and Evaluation Program IPZ Ingestion Pathway Zone IWP Initial Warning Point JIC Joint Information Center KCoEOC Kent County EOC KI Potassium Iodide LCD Liquid Crystal Display LHD Local Health Department MDDT Mobile Data Display Terminal MDT Mobile Data Terminals MHz Megahertz MIDAS Meteorological Information Dose Assessment System MS-1 Medical Services Hospital MSEL Master Scenario Events List NCCASDAGWMS New Castle County ASD Alfred G. Waters Middle School NCCEOC New Castle County EOC 33

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station NCCRCSRCDNG New Castle County Reception Center, Stem Readiness Center, Delaware National Guard NCDCEMS New Castle County Delaware City Emergency Medical Squad OSD Optically Stimulated Dosimeter PA Public Affairs PAD Protective Action Decision PAG Protective Action Guidelines PAR Protective Action Recommendation PARA Primary Area Route Alerting PAZ Protective Action Zone PD Police Department PDAFN Persons with Disabilities/ Access and Functional Needs PED Personal Electronic Dosimeter PIO Public Information Officer PPE Personal Protective Equipment PRA Primary Route Alerting PRD Permanent Record Dosimeter RAC Regional Assistance Committee RACES Radio Amateur Civil Emergency Services RAO Radiation Assessment Officer RDO Radiation Defense Officer REA Radiation Emergency Area REC Radiation Exposure Control REP Radiological Emergency Plan RERP Radiological Emergency Response Plan RHP Radiological Health Program RML Radiological Mobile Laboratory RO Radiological Officer ROO Radiological Operations Officer RTF Radiological Task Force SA Staging Area SAC Staging Area Coordinator SAE Site Area Emergency SAIC Science Applications International Corporation SAM Staging Area Manager SCBA Self-Contained Breathing Apparatus SEOC State Emergency Operations Center SERS State Emergency Radio System SFMT State Field Monitoring Team SHCENC(NJ)

Salem Hope Creek Emergency News Center (NJ) 34

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station STAC/DELDOT/DSP State Traffic and Access Control, Delaware Dept. of Transportation, Delaware State Police so State Official SOP Standard Operating Procedure SRO School Resources Officer sso Social Services Officer TAC Technical Assessment Center TCP Traffic Control Point TEDE Total Effective Dose Equivalent TO Transportation Officer UEM Utility Emergency Manager VHF Very High Frequency VMS Variable Message Sign VOIP Voice Over Internet Protocol 35

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Action Report/Improvement Plan Radiological Emergency Preparedness Program (REP)

Salem and Hope Creek Nuclear Generating Station APPENDIX D: METHOD OF OPERATION AND EXTENT OF PLAY AGREEMENT The 2016 Salem and Hope Creek Nuclear Generating Station Plume Exercise Extent-of-Play was negotiated and agreed upon by FEMA Region III, Delaware Emergency Management Agency (DEMA), and the Emergency Management Agencies of the Risk Counties. '

36

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Extent of Play INTRODUCTION The purpose of this appendix is to establish those exercise evaluation areas and corresponding Extent-of-Play parameters expected to be demonstrated during the SHCNGS 2016 Exercise to be conducted on May 17, 2016.

This exercise is being conducted in close cooperation with the State of New Jersey. The New Jersey Office of Emergency Management (NJOEM) will submit a separate Exercise Plan and Extent of Play to FEMA Region IL These evaluation areas have been developed through reviews of past exercises, associated plans and procedures, the proposed exercise scenario, applicable FEMA guidance documents, and extensive discussions with FEMA representatives All demonstrations will be conducted in accordance with established plans and procedures, except as indicated for specific exercise evaluation areas described herein.

There were no previous exercise issues that will require corrective action by the State of Delaware during this exercise.

37

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Action Report/Improvement Plan Radiological Emergency Preparedness Program (REP)

Salem and Hope Creek Nuclear Generating Station Participation and Locations*

The following locations were activated for this exercise. Out of Sequence demonstration locations are listed in the next section.

State Emergency Operations Center (EOC)

State Technical Assessment Center (TAC)

Emergency News Center/Joint Information Center (ENC/IlC)

Delaware National Guard (DNG) Field Teams Traffic and Access Control Points County Jurisdictions New Castle County EOC Kent County EOC 38

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Out of Sequence Demonstrations Some demonstrations will be conducted out-of-sequence. These demonstrations have been noted in the applicable evaluation area(s) in the Extent of Play and are summarized below.

Transportation Dependent Evaluation will occur on April 20, 2016 at 1 :00 pm. Demonstration will be by interview at the staging area: DART Wrangle Hill Road Facility, 2101 Mid County Drive, New Castle, Delaware 19720. (Intersection of SR 72 and US 13)

EPZ Districts and Schools Evaluation ofthis will occur on April 20, 2016. The Appoquinimink School district will be evaluated at 9:00 am at the district office. School evaluation will occur at the Alfred G. Waters Middle School at 9:00 am.

Reception Center Evaluation ofthis location will occur on April 21, 2016 at 9:00 am at the Stem Readiness Center.

MS-1 Evaluation of the MS-1 Drill will occur on May 6, 2016 at 9:00 am at Christiana Hospital, with Delaware City EMS providing patient transport, New Castle County Paramedics providing life support. Incident site: DART Wrangle Hill Road Facility, 2101 Mid County Drive, New Castle, Delaware 19720 (intersection of SR 72 and US 13)

. 39

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Extent of Play by Evaluation Area The following evaluation areas, sub-elements and evaluation criterion are consistent with FEMA's exercise evaluation methods. Extent of play text from the REP Manual is quoted verbatim for each evaluation criterion. All activities will be demonstrated in accordance with established plans and procedures, except as indicated in the negotiated extent of play for each evaluation criterion.

ASSESSMENT AREA 1: EMERGENCY OPERATIONS MANAGEMENT Sub-element 1.a - Mobilization Intent This Sub-element is derived from NUREG-0654/FEMA-REP-1, which requires that OROs have the capability to alert, notify, and mobilize emergency personnel, and activate and staff emergency facilities.

Criterion 1.a.1: OR Os use effective procedures to alert, notify, and mobilize emergency personnel and activatefacilities in a timely manner. (NUREG-0654/FEMA-REP-1,A.1.a, e; A.3, 4; C.1,4, 6; D.4; E.1, 2; G.3.a; H.3, 4)

Assessment/Extent of Play Assessment of this Demonstration Criterion may be accomplished during afull-scdle or functional exercise, an actual event, or by means of drills conducted at any time.

Responsible OROs must demonstrate the capability to receive notification of an incident from the licensee; verify the notification; and contact, alert, and mobilize key emergency personnel in a timely manner and demonstrate the ability to maintain and staff24-hour operations. Twenty-four-hour operations can be demonstrated during the exercise via rosters or shift changes or otherwise in an actual activation. Local responders must demonstrate the ability to receive and/or initiate notification to the licensees or other *respective emergency management organizations of an incident in a timely manner, when they receive information from the licensee or ~ltemate sources. Responsible OROs must demonstrate the activation of facilities for immediate use by mobilized personnel upon their arrival. Activation of facilities and staff, including those

.associated with the Incident Command System, must be completed in accordance with ORO plans/procedures. The location and contact information for facilities included in the incident command must be available to all appropriate responding agencies and the NPP after these facilities have been activated.

40

Radiological Emergency Preparedness (REP)/

Homeland Security Exercis.e and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station The REP program does not evaluate Incident Command System tactical operations, only coordination among the incident command, the utility, and all appropriate OROs, pursuant to plans/procedures.

Pre-positioning of emergency personnel is appropriate, in accordance with the Extent-of-Play Agreement, at those facilities located beyond a normal commuting distance from the individual's duty location or residence. This includes the staggered release of resources from an assembly area. Additionally, pre-positioning of staff for out-of-sequence demonstrations may be used in accordance with the Extent-of-Play Agreement.

Initial law enforcement, fire service, HAZMA T, and emergency medical response to the NPP site may impact the ability to staff REP functions. The ability to identify and request additional resources or identify compensatory measures must be demonstrated. Exercises must also address the role of mutual aid in the incident, as appropriate. An integral part of the response to an HAB scenario at an NPP may also be within the auspices of the Federal Government (e.g., FBI, NRC, or DHS). Protocols for requesting Federal, state, local, and tribal law enforcement support must be demonstrated, as appropriate. Any resources identified through LOA/MOUs must be on the ORO's mobilization list so they can be contacted during an incident, if needed. All activities must be based on the ORO's plans/procedures and completed as they would be in an actual emergency, unless noted above or otherwise specified in the Extent-of-Play Agreement.

Negotiated Extent of Play:

Responders will pre-position at the following facilities:

State EOC, Kent County EOC and New Castle County EOC Emergency Operating Facility (EOF), Salem, NJ Emergency News Center (ENC)- Woodstown, NJ Field Monitoring Teams -Delaware National Guard Headquarters Twenty-four hour rosters will be available for key players at each EOC. Mobilization of the following agencies will be simulated. Pre-staging is allowed:

Outstanding Issues: None 41

RadiolOgical Emergency Pr~paredness (REP)/

Homeland Security Exercise an~ Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Sub-element 1.b - Facilities Intent This Sub-element is derived from NUREG-0654/FEMA-REP-1, which requires that OROs have facilities to support the emergency response.

Criterion 1.b.l: Facilities are sufficient to support the emergency response. (NUREG-0654/FEMA-REP-1, G.3.a;H.3; J.10.h; J.12; K.5.b)

Assessment/Extent of Play Facilities will only be specifically evaluated for this criterion if they are new, or have substantial changes in structure or mission. Responsible OROs should demonstrate the availability of facilities that support the accomplishment of emergency operations. Some of the areas to be considered. are: adequate space, furnishings, lighting, restrooms, ventilation, backup power and/or alternate facility (if required to support operations).

Facilities must be set up based on the ORO's plans and procedures and demonstrated as they

  • would be used in an actual emergency, unless noted above or otherwise indicated in the extent of play agreement.

Negotiated Extent of Play:

This criterion will not be evaluated during this exercise as there are no new facilities or substantial changes to existing facilities.

r Outstanding Issues: None 42

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station.

Sub-element 1.c - Direction and Control Intent This Sub-element is derived from NUREG-0654/FEMA-REP-1, which requires that OROs have the capability to control their overall response to an emergency.

Criterion J.c.1: Key personnel with leadership roles for the ORO provide direction and control to that part of the overall response effort for which they are responsible. (NUREG-0654/FEMA-REP-1, A.1.d; A.2.a, b; A.3; C.4, 6)

Assessment/Extent of Pl_ay Assessment of this Demonstration Criterion may be accomplished in a full scale, functional, or

. tabletop exercise.

Leadership personnel must demonstrate the ability to carry out the essential management functions of the response effort (e.g., keeping staff informed through periodic briefings and/or other means, coordinating with other OROs, and ensuring completion of requirements and requests.) Leadership must demonstrate the ability to prioritize resource tasking and replace/supplement resources (e.g., through MOUs or other agreements) when faced with competing demands for finite resources. Any resources identified through LOA/MOUs must be on the ORO's mobilization list so they may be contacted during an incident, if needed.

All activities must be based on the ORO's plans/procedures and completed as they would be in*

an actual emergency, unless noted above or otherwise specified in the Extent-of-Play Agreement.

Negotiated Extent of Play:

All activities will be performed in accordance with the ORO's plans/procedures and completed as they would be in an actual emergency.

Outstandinglssues: None 43

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear _aenerating Station Sub-element 1.d - Communications Equipment Intent This Sub-element is derived from NUREG-0654/FEMA-REP-1, which requires that OROs establish and operate reliable primary and backup communication systems to ensure communications with key emergency personnel at locations such as contiguous governments within the EPZ, Federal emergency response organizations, the licensee and its facilities, EOCs, Incident Command Posts, and FMTs.

Criterion J.d.1: At least two communication systems are available, at least one operates properly, and communication links are established and maintained with appropriate locations.

Communications capabilities are managed in support of emergency operations. (NUREG-0654/J?Elt.fA-REl'-1, F:l, 2)

Assessment/Extent of Play Assessment of this Demonstration Criterion is accomplished initially in a baseline evaluation and subsequently in periodic testing and drills. System familiarity and use must be demonstrated as applicable in full scale, functional and tabletop exercises, or if their use would be required, during an actual event.

OROs must demonstrate that a primary system, and at least one backup system for fixed facilities, is fully functional at all times. Communications systems are maintained and tested on a recurring basis throughout the assessment period and system status is available.to all operators.

Periodic test results and corrective actions are maintained on a real< time basis. If a communications system or systems are not functional, but exercise performance is not affected, no exercise issue will be assessed.

Communications equipment and procedures for facilities and field units are used as needed for transmission and receipt of exercise messages. All facilities, FMTs, and incident comniand must have the capability to access at least one communication system that is independent of the commercial telephone system. Responsible OROs must demonstrate the capability to manage the communication systems and.ensure that all message traffic is handled without delays that might disrupt emergency operations. OROs must ensure that a coordinated communication link for fixed and mobile medical support facilities exists. Exercise scenarios may require the failure of a communication system and use of an alternate system, as negotiated in the Extent-of-Play Agreement. All activities must be based on the ORO's plans/procedures and completed as they would be in an actual emergency, unless noted above or otherwise specified in. the Extent-of-Play Agreement Negotiated Extent ofl'lay: All activities will be performed in accordance with the ORO's plans/procedures and completed as they would be in an actual emergency.

44

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Outstanding Issues: None 45

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

U ncl assifled Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Sub-element 1.e - Equipment and Supplies to Support Operations Intent This Sub-element is derived from NUREG-0654/FEMA-REP-1, which requires that OROs have emergency equipment and supplies adequate to support the emergency response.

Criterion I. e.1: Equipment, maps, displays, monitoring instruments, dosimetry, potassium iodide (KI) and other supplies are sufficient to support emergency operations (NUREG-0654/FEMA-REP-1, H.7, 10; L 7, 8, 9; J.10.a, b, e; J.11, 12; K.3.a; K.5.b)

Assessment/Extent of Play Assessment of this Demonstration Criterion is accomplished primarily through a baseline evaluation and subsequent periodic inspections.

A particular facility's equipment and supplies must be sufficient and consistent with that facility's assigned role in the ORO's emergency operations plans. Use of maps and other displays is encouraged. For non-facility-based operations, the equipment and supplies must be sufficient and *consistent with the assigned operational role. At locations where traffic and access control personnel are deployed, appropriate equipment (e.g., vehicles, barriers, traffic cones, and signs) must be available, or their availability described.

Specific equipment and supplies that must be demonstrated under this criterion include KI inventories, dosimetry, and monitoring equipment, as follows:

KI: Responsible OROs must demonstrate the capability to maintain inventories of KI sufficient for use by: (1) emergency workers; (2) institutionalized individuals, as indicated in capacity lists for facilities; and (3) where stipulated by the plans/procedures, members of the general public (including transients) within the plume pathway EPZ. In addition, OROs must demonstrate provisions to make KI available to specialized response teams (e.g., civil support team, Special Weapons and Tactics Teams, urban search and rescue, bomb squads, HAZMAT, or other ancillary groups) as identified in plans/procedures). The plans/procedures must include the forms to be used for documenting emergency worker ingestion of KI, as well as a mechanism for identifying emergency workers that have declined KI in advance. Consider carefully the placement of emergency workers that have declined KI in advance.

ORO quantities of dosimetry and KI available and storage locations(s) will be confirmed by physical inspection at the storage location(s) or through documentation of current inventory submitted during the exercise, provided in the ALC submission, and/or verified during an SAV.

Available supplies of KI must be within the expiration date indicated on KI bottles or blister packs. As an alternative, the ORO may produce a letter from a certified private or state 46

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station laboratory indicating that the KI supply remains potent, in accordance with U.S. Pharmacopoeia standards.

Dosimetry: Sufficient quantities of appropriate direct-reading and permanent record dosimetry and dosimeter chargers must be available for issuance to all emergency workers who will be dispatched to perform an ORO mission. In addition, OROs must demonstrate provisions to make dosimetry available to specialized response teams (e.g., civil support team, Special Weapons and Tactics Teams, urban search and rescue, bomb squads, HAZMAT, or other ancillary groups) as identified in plans/procedures).

Appropriate direct-reading dosimetry must allow an individual(s) to read the administrative reporting limits and maximum exposure limits contained in the ORO's plans/procedures.

Direct-reading dosimeters must be zeroed or operationally checked prior to issuance. The dosimeters must be inspected for electrical leakage at least annually and replaced when necessary. Civil Defense Victoreen Model 138s (CD V-138s) (0-200 mR), due to their documented history of electrical leakage problems, must be inspected for electrical leakage at least quarterly and replaced when necessary. This leakage testing will be verified during the exercise, through documentation submitted in the ALC and/or through an SAV.

Operational checks and testing of electronic dosimeters must be in accordance with the manufacturer's instructions and be verified during the exercise, through documentation submitted in the ALC and/or through an SAV.

Mutual Aid Resources: If the incoming resources arrive with their own equipment (i.e., monitors and/or dosimetry), they will be evaluated by REP Program standards. FEMA will not inventory equipment that is not part of the REP Program. If an agency has a defined role in the REP Plan, they are subject to the planning process and standards, as well as the guidance ofthis Manual.

Monitoring Instruments: All instruments must be inspected, inventoried, and operationally checked before each use. Instruments must be calibrated in accordance with the manufacturer's recommendations. Unmodified CDV-700 series instruments and other instruments without a manufacturer's recommendation must be calibrated annually. Modified CDV-700 instruments must be calibrated in accordance with the recommendation of the modification manufacturer. A label indicating such calibration must be on each instrument or calibrated frequency can be verified by other means. In addition, instruments being used to measure activity must have a sticker-affixed to their sides indicating the effective range of the readings. The range of readings documentation specifies the acceptable range of readings that the meter should indicate when it is response-checked using a standard test source.

For FMTs, the instruments must be capable of measuring gamma exposure rates and detecting beta radiation. These instruments must be capable of measuring a range of activity and exposure, including radiological protection/exposure control of team members and detection of activity on air sample collection media, consistent with the intended use of the instrument and 47

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station the ORO's plans/procedures. An appropriate radiqactive check source must be used to verify proper operational response for each low-range radiation measurement instrument (less than lR/hr) and for high-range instruments when available. If a source is not available for a high-range instrument, a procedure must exist to operationally test the instrument before entering an area where only a high-range instrument can make useful readings.

In areas where portal monitors are used, the OROs must set up and operationally check the monitor(s). The monitor(s) must conform to the standards set forth in the Contamination Monitoring Standard for a Portal Monitor Used for Emergency Response, FEMA-REP-21 (March 1995) or in accordance with the manufacturer's recommendations.

All activities must be based on the ORO's plans/procedures and completed as they would be in an actual emergency, unless noted above or otherwise specified in the Extent-of-Play Agreement.

Negotiated Extent of Play:

The evaluators will meet the Field Monitoring Teams at 3 pm on May 17th at the DNG Headquarters to observe equipment operability checks.

Traffic and Access Control - Evaluation of criteria related to Traffic and Access Control will occur on May 17, 2016. Demonstration will be by interview at the State EOC between 6:00 p.m.

and 7:00 p.m. Deployment of traffic equipment will be simulated. _Equipment will be available for review in the State EOC parking lot. Radiological Emergency Worker.kit (dosimeters and anti-contamination suit) will be available at the State EOC during the interview.

Outstanding Issues: None 48

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station ASSESSMENT AREA 2: PROTECTIVE ACTION DECISION-MAKING Sub-element 2.a-:- Emergency Worker Exposure Control Intent This Sub-element is derived from NUREG-0654/FEMA-REP-1, which requires that OROs have the capability to assess and control the radiation exposure received by emergency workers and have a decision chain in place, as specified in the ORO's plans/procedures, to authorize emergency worker exposure limits to be exceeded for specific missions.

Radiation exposure limits for emergency workers are the recommended accumulated dose limits or exposure rates that emergency workers may be permitted to incur during an emergency.

These limits include any pre-established administrative reporting limits (that take into consideration TEDE or organ-specific limits) identified in the ORO's plans/procedures.

Criterion 2.a.1: OROs use a decision-making process, considering relevant/actors and appropriate coordination, to ensure that an exposure control system, including the use of KI, is in place for emergency workers, including provisions to authorize radiation exposure in excess of administrative limits or protective action guides. (NUREG-0654/FEMA-REP-1, C.6; J.10~ e,f; K.3.a; K.4)

Assessment/Extent of Play Assessment of this Demonstration Criterion must be assessed concurrently with a licensee exercise and may be demonstrated in a biennial or tabletop exercise.

OROs authorized to send emergency workers into the plume exposure pathway EPZ must demonstrate a capability to comply with emergency worker exposure limits based on their emergency plans/procedures.

Participating OROs must also demonstrate the capability to make decisions concerning authorization of exposure levels in excess of pre-authorized levels and the number of emergency workers receiving radiation doses above pre-authorized levels. This would include providing KI and dosimetry in a timely manner to emergency workers dispatched onsite to support plant incident assessment and mitigating actions, in accordance with respective plans/procedures.

As appropriate, OROs must demonstrate the capability to make decisions on the distribution and administration of KI as a protective measure for emergency workers, based on their plans/procedures or projected thyroid dose compared with the established PAGs for KI administration.

49

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Action Report/Improvement Plan Radiological Emergency Preparedness Program (REP)

Salem and Hope Creek Nuclear Generating Station All activities must be based on the ORO's plans/procedures and completed as they would be in an actual emergency, unless noted above or otherwise specified in the Extent-of-Play Agreement.

Negotiated Extent of Play:

All activities will be performed in accordance with the ORQ',s plans/procedures and completed as they would be in an actual emergency.

Outstanding Issues: None 50

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Sub-element 2.b. - Radiological Assessment and Protective Action Recommendations and Decisions for the Plume Phase of the Emergency Intent This Sub-element is derived from NURBG-0654/FEMA-REP-l, which requires that OROs have.

the capability to independently project integrated dose from projected or actual dose rates and compare these estimates to the PA Gs.

OROs must have the capability to choose, among a range of protective actions, those most appropriate in a given emergency. OR Os base these choices on PA Gs from their plans/procedures or EPA 's Manual of Protective Action Guides and Protective Actions for Nuclear Incidents and other criteria, such as plant conditions, licensee P ARs; coordination of P ADs with other political jurisdictions (e.g., other affected OROs and incident command),

availability of in-place shelter, weather conditions, and situations, to include RAB incidents, the threat posed by the specific hostile action, the affiliated response, and the effect of an evacuation on the threat. response effort, that create higher than normal risk from general population evacuation.

Criterion 2.b.l: Appropriate protective action recommendations (PARs) are based on available information on plant conditions, field monitoring data, and licensee and ORO dose projections, as well as knowledge of onsite and of/site environmental conditions. (NUREG-0654/FEMA-REP-1, LIO and Supplement 3)

Assessment/Extent of Play Assessment of this Demonstration Criterion must be accomplished concurrently with a licensee exercise and may be demonstrated in a biennial or tabletop exercise.

During the initial stage of the emergency response, following notification of plant conditions that may warrant offsite protective actions, the ORO must demonstrate the capability to use appropriate means, described in the plans/procedures, to develop P ARs for decision-makers based on available information and recommendations provided by the licensee as well as field monitoring data, if available. The ORO must also consider any release and meteorological data provided by the licensee.

The ORO must demonstrate a reliable capability to independently validate dose projections. The types of calculations to be demonstrated depend on the data available and the need for assessments to support the P ARs must be appropriate to the scenario. In all cases, calculation of projected dose must be demonstrated. Projected doses must be related to quantities and units of the P AG to which they will be compared. P ARs must be promptly transmitted to decision-makers in a pre-arranged format.

51

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station When the licensee and ORO projected doses differ by more than a factor of 10, the ORO and licensee must determine the source of the difference by discussing input data and assumptions, using different models, or exploring possible reasons. Resolution of these differences must be incorporated into the*PARs if timely and appropriate. The ORO must demonstrate the capability to use any additional data to refine projected doses and exposure rates and revise the associated PARs.

All activities must be based on the ORO's plans/procedures and completed as they would be in an actual emergency, unless noted above or otherwise specified in the Extent-of-Play Agreement.

Negotiated Extent of Play:

All activities will be performed in accordance with the ORO's plans/procedures and completed as they would be in an actual emergency.

Outstanding Issues: None 52

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Criterion 2.b.2: A decision-making process involving consideration of appropriate factors and necessary coordination is used to make protective action decisions (PADs)for the general

  • public (including the recommendation for the use of Kl, if ORO policy). (NUREG-0654/FEMA-REP-1,A.3; C.4, 6; D.4; J.9; J.10.f, m)

Assessment/Extent of Play Assessment of this Demonstration Criterion must be accomplished concurrently with a licensee exercise and may be demonstrated in a full-scale, functional or tabletop exercise.

OROs must have the capability to make both initial and subsequent P ADs. OROs must demonstrate the capability to make initial P ADs in a timely manner appropriate to the incident, based on information from the licensee, assessment of plant status and potential or actual releases, other available information related to the incident, input from appropriate ORO authorities (e.g., incident command), and PARs from the utility and ORO staff. In addition, a subsequent or alternate PAD may be appropriate if various conditions (e.g., an HAB incident, weather, release timing and magnitude) pose undue risk to an evacuation, or if evacuation may disrupt the efforts to respond to a hostile action.

OROs must demonstrate the ability to obtain supplemental resources (e.g., mutual aid) necessary to implement a Precautionary and/or Protective Action Decision if local law enforcement, fire service, HAZMA T, and emergency medical resources are used to augment response to the NPP site or other key infrastructure.

Dose assessment personnel may provide additional P ARs based on the subsequent dose projections, field monitoring data, or information on plant conditions. In addition, incident command must provide input regarding considerations for subsequent P ARs based on the magnitude of the ongoing threat, the response, and/or site conditions. The decision-makers must demonstrate the capability to change protective actions based on the combination of all these factors.

If the ORO has determined that KI will be used as a protective measure for the general public under offsite plans/procedures, then it must demonstrate the capability to make decisions on the distribution and administration of KI to supplement sheltering and evacuation. This decision must be based on the ORO's plans/procedures or projected thyroid dose compared with the established P AG for KI administration. The KI decision-making process must involve close coordination with appropriate assessment and decision-making staff.

If more than one ORO is involved in decision making, all appropriate OROs must communicate and coordinate P ADs with each other. In addition, decisions must be coordinated/communicated with incident command. OROs must demonstrate the capability to communicate the results of decisions to all the affected locations.

53

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan

. Salem and Hope Creek Nuclear Generating Station The OROs must demonstrate how the decision-making process takes those with disabilities and access/functional needs (e.g., nursing homes, correctional facilities, licensed day cares, mobility-impaired individuals, and transportation-dependent individuals) into account.

All activities must be based on the ORO's plans/procedures and completed as they would be in an actual emergency, unless ~ted above or otherwise specified in the Extent-of-Play Agreement.

Negotiated Extent of Play:

All activities will be performed in accordance with the ORO's plans/procedures and.completed as they would be in an actual emergency.

Outstanding Issues:

None 54

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating StatioQ Sub-element 2.c - Precautionary and/or Protective Action Decisions Consideration for the Protection of Persons with Disabilities and Access/Functional Needs Intent This Sub-element is derived from NUREG-0654/FEMA-REP-l, which requires that OROs have the capability to determine Precautionary and/or Protective Action Decisions including evacuation, sheltering, and use of KI, if applicable, for groups of persons with disabilities and access/functional needs (e.g., hospitals, nursing homes, correctional facilities, schools, licensed daycare centers, mobility-impaired individuals, and transportatiOn-dependent individuals). The focus is on those groups of persons with disabilities and access/functional needs that are, or potentially will be, affected by a radiological release from an NPP.

Criterion 2.c.1: Precautionary and/or Protective action decisions are made, as appropriate,for groups of persons with disabilities and access/functional needs. (NUREG-0654/FEMA-REP-1,D.4; J.9; J.1 O.d, e)

Assessment/Extent of Play Assessment of this Demonstration Criterion must be accomplished concurrently with a licensee exercise and may be demonstrated in a full-scale, functional or tabletop exercise that would include the use of plant conditions transmitted from the licensee.

Usually it is appropriate to implement evacuation in areas where doses are projected to exceed the lower end of the range of PAGs, except for incidents where there is a high-risk environmental condition or where high-risk groups (e.g., the immobile or infirm) are involved.

In these cases, factors that must be considered include weather conditions, shelter availability, availability of transportation assets, risk of evacuation versus risk from the avoided dose, and precautionary school evacuations. In addition, decisions must be coordinated/communicated with the incident command. In situations where an institutionalized population cannot be evacuated, the ORO must consider use of KI.

Applicable OROs must demonstrate the capability to alert and notify all public school systems/districts of emergency conditions that are expected to or may necessitate protective actions for students. Demonstration requires that the OROs actually contact public school systems/districts during the exercise.

In accordance with plans/procedures~ OROs and/or officials of public school systems/districts must demonstrate the capability to make prompt decisions on protective actions for students.

The decision-making process, including any preplanned strategies for protective actions for that ECL, must consider the location of students at the time (e.g., whether the students are still at home, en route to school, or at school).

55

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Action Report/Improvement Plan Radiological Emergency Preparedness Program (REP)

Salem and Hope Creek Nuclear Generating Station All activities must be based on the ORO's plans/procedures and completed as they would be in an actual emergency, unless noted above or otherwise specified in the Extent-of-Play Agreement.

Negotiated Extent of Play:

All activities will be performed in accordance with the ORO's plans/procedures and completed as they would be in an actual emergency.

Outstanding Issues: None 56

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Sub-element 2.d. - Radiological Assessment and Decision Making for the Ingestion Exposure Pathway Intent This Sub-element is derived from NUREG-0654/FEMA-REP-1, which requires that OROs have the means to assess the radiological consequences for the ingestion exposure pathway, relate them to the appropriate P AGs, and make timely, appropriate P ADs to mitigate exposure from the pathway.

During an incident at an NPP, a release of radioactive material may contaminate water supplies 1 and agricultural products in the surrounding areas. Any such contamination would likely occur during the plume phase of the incident and, depending.on the nature of the release, could impact the ingestion pathway for weeks or years.

Criterion 2.d.l: Radiological consequences for the ingestion pathway are assessed and appropriate protective action decisions are made based on the ORO's planning criteria.

(NUREG-0654/FEMA-REP-1, A.3; C.1, 4; D.4; J.9,11)

Assessment/Extent of Play Assessment of this Demonstration Criterion must be accomplished concurrently with a licensee exercise and may be demonstrated in a full-scale, functional or tabletop exercise that would include the use of plant conditions transmitted from the licensee.

OROs are expected to take precautionary actions to protect food and water supplies, or to minimize exposure to potentially contaminated water and food, in accordance with their respective plans/procedures. Often OROs initiate such actions based on criteria related to the facility's ECLs. Such actions may include recommendations to place milk animals on stored feed and use protected water supplies.

The ORO must use its procedures to assess the radiological consequences of a release on the food and water supplies, such as the development of a sampling plan. The ORO's assessment must include evaluation of the radiological analyses ofrepresentative samples of water, food, and other ingestible substances of local interest from potentially impacted areas;.characterization of the releases from the facility; and the extent of areas potentially impacted by the release.

During this assessment, OROs must consider use of agricultural and watershed data within the.

50-mile EPZ. The radiological impacts on the food and water must then be compared to the appropriate ingestion PAGs contained in the ORO's plans/procedures. The plans/procedures contain P AGs based on specific dose commitment criteria or on criteria as recommended by current Food and Drug Administration (FDA) guidance. Timely and appropriate recommendations must be provided to the ORO decision-makers group for implementation 57

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station decisions. OROs may also include a comparison of taking or not taking a given action on the resultant ingestion*pathway dose commitments.

The ORO must demonstrate timely decisions to minimize radiological impacts from the ingestion pathway, based on the given assessments and other information. Any such decisions must be communicated and, to the extent practical, coordinated with neighboring OROs. These decisions include tracking agricultural products entering and leaving the EPZ. Demonstration of plans and procedures which use traffic access control points to track agricultural products entering and leaving the EPZ may be conducted through interview.

OROs will use Federal resources, as identified in the Nuclear/Radiological Incident Annex of the NRF and other resources (e.g., compacts or nuclear insurers). Evaluation of this criterion will take into consideration the level of Federal and other participating resources.

All activities must be based on the ORO' s plans/procedures and completed as they would be in an actual emergency, unless noted above or otherwise specified in the Extent-of-Play Agreement.

Negotiated Extent of Play:

This criterion will not be evaluated for this exercise.

Outstanding Issues:

None 58

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Sub-element 2.e. - Radiological Assessment and Decision Making Concerning Post-Plume Phase Relocation, Reentry, and Return Intent This Sub-element is derived from NUREG-0654/FEMA-REP-1, which requires that OROs have the capability to make decisions on post-plume phase relocation, reentry, and return of the general public. These decisions are essential for protection of the public from direct long-term exposure to deposited radioactive materials from a severe incident at an NPP.

Criterion 2.e.1: Timely post-plume phase relocation, reentry, and return decisions are made and coordinated as appropriate, based on assessments of the radiological conditions and criteria in the ORO's plan and/or procedures. (NUREG-0654/FEMA-REP-1, LlO; J.9; K.3.a; M.1)

Assessment/Extent of Play Assessment of this Demonstration Criterion must be accomplished concurrently with a licensee exercise and may be demonstrated in a full-scale, functional or tabletop exercise that would include the use of plant conditions transmitted from the licensee.

Relocation: OROs must demonstrate the capability to estimate integrated dose in contaminated areas and compare these estimates with PA Gs; apply decision criteria for relocation of those individuals in the general public who have not been evacuated, but where actual or projected doses are in excess of relocation PA Gs; and control access to evacuated and restricted areas.

OR Os will make decisions for relocating members of the evacuated public who lived in areas that now have residual radiation levels in excess of the PAGs. Determination of areas to be restricted must be based on factors such as the mix of radionuclides in deposited materials, calculated exposure rates versus the PA Gs, and analyses of vegetation and soil field samples.

Reentry: Decisions must be made on location of control points and policies regarding access and exposure control for emergency workers and members of the general public who need to temporarily enter the evacuated area to perform specific tasks or missions.

Examples of control procedures are the assignment of, or checking for, direct-reading and permanent record dosimetry for emergency workers; questions regarding an individual's objectives, locations expected to be visited, and associated timeframes; availability of maps and plots of radiation exposure rates; and advice on areas to avoid. Control procedures also include monitoring of individuals, vehicles, and equipment; the implementation of decision criteria regarding decontamination; and proper disposition of emergency worker dosimetry and maintenance of emergency worker radiation exposure records.

59

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Responsible OROs must demonstrate the capability to develop a strategy for authorized reentry of individuals into the restricted zone(s), based on established decision criteria. OROs must demonstrate the capability to modify those policies for security purposes (e.g., police patrols),

maintenance of essential services (e.g., fire protection and utilities), and other cfitical functions.

They must demonstrate the capability to use decision-making criteria in allowing access to the restricted zone by the public for various reasons, such as to maintain property (e.g., to care for farm animals or secure machinery for storage) or retrieve important possessions. Coordinated policies for access and exposure control must be developed among all agencies with roles to perform in the restricted zone(s). OROs must demonstrate the capability to establish policies for provision of dosimetry to all individuals allowed to reenter the restricted zone(s). The extent to which OROs need to develop policies on reentry will be determined by scenario events.

Return: OROs must demonstrate the capability to implement policies concerning return of members of the public to areas that were evacuated during the plume phase (i.e., permitting populations that were previously evacuated to reoccupy their homes and businesses on an unrestricted basis). OROs must base decisions on environmental data and political boundaries or physical/ geological features, which allow identification of the boundaries of areas to which members of the general public may return. Return is permitted to the boundary of the restricted area( s) that is based on the relocation PA G.

Other factors that the ORO must consider in decision-making include conditions that permit cancellation of the ECL and relaxation of associated restrictive measures. OR Os must base return recommendations on measurements of radiation from ground deposition. OROs must have the capability to identify services and facilities that require restoration within a few days and to identify the procedures and resources for their restoration. Examples of these services and facilities are medical and social services, utilities, roads, schools, and intermediate-term housing for relocated persons.

All activities must be based on the ORO's plans/procedures and completed as they would be in an actual emergency, unless noted above or otherwise specified in the Extent-of-Play Agreement.

Negotiated Extent of Play:

This criterion will not be evaluated for this exercise.

Outstanding Issues:

None 60

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station ASSESSMENT AREA 3: PROTECTIVE ACTION IMPLEMENTATION Sub-element 3.a - Implementation of Emergency Worker Exposure Control Intent This Sub-element is derived from NUREG-0654/FEMA-REP-1, which requires that OROs have the capability to provide for the following: distribution, use, collection, and processing of direct-reading dosimetry and permanent record dosimetry; reading of direct-reading dosimetry by emergency workers at appropriate frequencies; maintaining a radiation dose record for each emergency worker; establishing a decision chain or authorization procedure for emergency workers to incur radiation exposures in excess of the PAGs, and the capability to provide KI for

  • emergency workers, always applying the "as low as is reasonably achievable" principle as appropriate. -

Criterion 3.a.1: The OROs issue appropriate dosimetry, KI, and procedures, and manage radiological exposure to emergency workers in accordance with the plans/procedures.

Emergency workers periodically and at the end of each mission read their dosimeters and record the readings on the appropriate exposure record or chart OROs maintain appropriate record-keeping of the administration of KI to emergency workers. (NUREG-0654/FEMA-REP-1, J.10.e; K.3.a, f!; K.4)

Assessment/Extent of Play Assessment of this Demonstration Criterion may be accomplished during a full-scale, functional or tabletop exercise. Other means may include drills, seminars or training activities that would fully demonstrate technical proficiency.

OROs must demonstrate the capability to provide emergency workers (including supplemental resources) with the appropriate direct-reading and permanent record dosimetry, dosimeter chargers, KI, and instructions on the use of these items. For evaluation purposes, appropriate direct-reading dosimetry is defined as dosimetry that allows an individua:l(s) to read the administrative reporting limits that are pre-established at a level low enough to consider subsequent calculation of TEDE and maximU.m exposure limits, for those emergency workers involved in lifesaving activities, contained in the ORO's plans/procedures.

Each emergency worker must have basic knowledge of radiation exposure* limits as specified in the ORO's plans/procedures. If supplemental resources are used, they must be provided with just-in-time training to ensure basic knowledge of radiation exposure control. Emergency workers must demonstrate procedures to monitor and record dosimeter readings and manage radiological exposure control.

61

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan*

Salem and Hope Creek Nuclear Generating Station During a plume phase exercise, emergency workers must demonstrate the procedures to be followed when administrative exposure limits and tum-back values are reached. The emergency worker must report accumulated exposures during the exercise as indicated in the plans/procedures. OROs must demonstrate the actions described in the plans/procedures by determining whether to replace the worker, authorize the worker to incur additional exposures, or take other actions. If exercise play does not require emergency workers to seek authorizations for additional exposure, evaluators must interview at least two workers to determine their knowledge of whom to contact in case authorization is needed, and at what exposure levels.

Workers may use any available resources (e.g., written procedures and/or coworkers) in providing responses.

Although it is desirable for all emergency workers to each have a direct-reading dosi,meter, there may be situations where team members will be in close proximity to each other during the entire mission. In such cases, adequate control of exposure can be achieved for all team members

_using one direct-reading dosimeter worn by the team leader. Emergency workers assigned to low-exposure rate fixed facilities (e.g., EOCs and communications center within the EPZ, reception centers, and counting laboratories) may have individual direct-reading dosimeters or they may be monitored using group dosimetry (i.e., direct-reading dosimeters strategically placed in the work area). Each team member must still have his or her own permanent record dosimetry. Individuals authorized by the ORO to reenter an evacuated area during the plume (emergency) phase, must be limited to the lowest radiological exposure commensurate with completing their missions.

OR Os may have administrative limits lower than EP A-400-R-92-001 dose limits for emergency workers performing various services (e.g., lifesaving, protection of valuable property, all activities). OROs must ensure that the process used to seek authorization for exceeding dose limits does not negatively impact the capability to respond to an_ incident where lifesaving and/or protection of valuable property may require an urgent response.

0 ROs must demonstrate the capability to accomplish distribution of Kl to emergency workers consistent with decisions made. OROs must have the capability to develop and maintain lists of emergency workers who have ingested KI, including documentation of the date(s) and time(s) they did so. Ingestion of KI recommended by the designated ORO health official is voluntary.

For evaluation purposes, the actual ingestion of KI shall not be performed. OROs must demonstrate the capability to formulate and disseminate instructions on using KI for those advised to take it. Emergency workers must demonstrate basic knowledge of procedures for using Kl whether or not the scenario drives the implementation of Kl use. This can be accomplished by an interview with the evaluator.

All activities must be based on the ORO's plans/procedures and completed as they would be in an actual emergency, unless noted above or otherwise specified in the Extent-of-Play Agreement.

62

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Negotiated Extent of Play:

All activities will be performed in accordance with the ORO's plans/procedures and completed as they would be in an actual emergency. If directed to take, KI will be simulated.

Outstanding Issues: None 63

Radiological Emergency Preparedness (REP)/

Homeland Security.Exercise and Eval.uation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Sub-element 3.b - Implementation of KI Decision for Institutionalized Individuals and the General Public Intent This Sub-element is derived from NUREG-0654/FEMA-REP-1, which requires that OROs have the capability to provide Kl for institutionalized individuals, and, if in the plans/procedures, to the general public for whom immediate evacuation may not* be feasible, very difficult, or significantly delayed. While it is necessary for OROs to have the capability to provide Kl to institutionalized individuals, providing Kl to the general public is an ORO option and must be reflected as such in ORO plans/procedures. Provisions must include the availability of adequate quantities, storage, and means of distributing Kl.

Criterion 3.b.1: KI and appropriate instructions are available if a decision to recommend use of KI is made. Appropriate record-keeping of the administration of KI for institutionalized individuals and the general public is maintained. (NUREG-0654/FEMA-REP-1, J.10.e,j)

Assessment/Extent of Play Assessment of this Demonstration Criterion may be accomplished during afull-scale,functional or tabletop exercise. Other means may include drills, seminars or training activities that would fully demonstrate technical proficiency.

OROs must demonstrate the capability to make Kl available to institutionalized individuals, and, where provided for in their plans/procedures, to members of the general public. OROs must demonstrate the capability to accomplish distribution of Kl consistent with decisions made.

OROs must have the capability to develop and maintain lists of institutionalized individuals who have ingested KI, including documentation of the date(s) and time(s) they were instructed to*

_ingest Kl. Ingestion of KI recommended by the designated ORO health official is voluntary.

For evaluation purposes, the actual ingestion of KI shall not be performed. OROs must demonstrate the capability to formulate and disseminate instructions on using Kl for those advised to take it.

(

If a recommendation is made for the general public to take KI, appropriate information must be provided to the public by the means of notification specified in the ORO's plans/procedures.

All activities must be based on the ORO's plans/procedures and completed as they would be in an actual emergency, unless noted above or otherwise specified in the Extent-of-Play Agreement.

Negotiated Extent of Play: If directed, ingestion of KI will be simulated.

Outstanding Issues: None 64

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Pieparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Sub-element 3.c - Implementation of Protective Actions for Persons with Disabilities and Access/Functional Needs Intent "

This Sub-element is derived from NUREG-0654/FEMA-REP-1, which requires that OROs have the capability to implement P ADs, including evacuation and/or sheltering, for all persons with disabilities and access/functional needs. The focus is on those persons.with disabilities and

  • access/functional needs that are (or potentially will be) affected by a radiological release from an NPP.

Criterion 3.c.1: Protective action decisions are implemented/or persons with disabilities and access/functional needs other than schools within areas subject to protective actions.

(NUREG-0654/FEMA-REP-1, J.10.c, d, e, g)

Assessment/Extent of Play Assessment of this Demonstration Criterion may be accomplished during a full-scale or functional exerc!se, an actual event, or by means of drills conducted at any time.

Applicable OROs must demonstrate the capability to alert and notify (i.e., provide P ARs and emergency information and instructions to) persons with disabilities and access/functional needs, including hospitals/medical facilities, nursing-homes, correctional facilities, and mobility-impaired and transportation-dependent individuals. OROs must demonstrate the capability to provide for persons with disabilities and access/functional needs in accordance with plans/procedures.

Contact with persons with disabilities and access/functional needs and reception facilities may be actual or simulated, as agreed to in the extent of play. Some contacts with transportation providers must be actual, as negotiated in the extent of play. All actual and simulated contacts must be logged.

All activities must be based on the ORO's plans/procedures and completed as they would be in an actual emergency, unless noted above or otherwise specified in the Extent-of-Play Agreement.

Negotiated Extent of Play:,

There will be no actual notification of Persons with Disabilities and Access/Functional Needs.

List of institutionalized Persons with Disabilities and Access/Functional Needs will be available at the State EOC for the Evaluator.

65

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Action Report/Improvement Plan Radiological Emergency Preparedness Program (REP)

Salem and Hope Creek Nnclear Generating Station List of individual Persons with Disabilities and Access/Functional Needs will be available at the Kent County EOC and New Castle County EOC.

Evaluation of the portion of this criterion related to Transit Dependent will occill on April 20, 2016 at 1 :00 pm. Demonstration will be by interview at the staging area: DART Wrangle Hill Road Facility, 2101 Mid County Drive, New Castle, Delaware 19720. (Intersection of SR 72 and US 13)

Outstandinglssues: None 66

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Criterion 3.c.2: OROs/School officials implement protective actions for schools. (NUREG-0654/FEMA-REP-1, J.10.c, d, e, g)

Assessment/Extent of Play Assessment of this Demonstration Criterion may be accomplished during a full-scale or functional exercise, an actual event, or by means of drills conducted at any time.

Public school systems/districts must demonstrate the ability to implement P ADs for students.

The demonstration must be made as follows: Each school system/district within the 10 mile EPZ must demonstrate implementation of protective actions. At least one school per affected system/district must participate in the demonstration. Canceling the school day, dismissing early, or sheltering in place must be simulated by describing to evaluators the procedures that would be followed. If evacuation is the implemented protective action, all activities to coordinate and complete the evacuation of students to reception centers, congregate care centers, or host schools may actually be demonstrated or accomplished through an interview process.

If accomplished through an interview, appropriate school personnel including decision-making officials (e.g., schools' superintendent/principals and transportation director/bus dispatchers),

and at least one bus driver (and the bus driver's escort, if applicable) must be available to demonstrate knowledge of their role( s) in the evacuation of school children. Communications capabilities between school officials and the buses, if required by the plans/procedures, must be verified.

Officials of the school system(s) must demonstrate the capability to develop and provide timely information to OROs for use in messages to parents, the general public, and the media on the status of protective actions for schools.

If a school facility has emergency plans as a condition of licensing, those plans may be submitted to FEMA review in place of demonstration or interview pursuant to the ORO's plans/procedures as negotiated in the Extent-of-Play Agreement.

All activities must be based on the ORO's plans/procedures and completed as they would be in an actual emergency, unless noted above or otherwise specified in the Extent-of-Play Agreement.

Negotiated Extent of Play:

Evaluation ohhis criterion will occur on April 20, 2016 and during the exercise on May 17th.

The Appoquinimink School district will be evaluated at 9:00 am. School evaluation will occur at the Alfred G. Waters Middle School at 9:00 am.

School principals or designees, Superintendent or designees, and bus drivers will be interviewed on procedures. A bus will be available at each school, for equipment (communications and 67

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station maps) observation. However, the school children will not be involved with the demonstration nor will the buses be driven to the designated routes. Interviews will be conducted at the school listed above.

Portions of this criterion will be demonstrated during the exercise on May 17th at a mutually agreed upon time.

The Department of Education (DOE) representative at the State EOC will demonstrate their procedures for the evaluator.

Private schools, private kindergartens and licensed day cares do not participate in REP Exercises.

A list of licensed day cares will be available at the State EOC. The process of notification procedures will be demonstrated and documented. The licensed day care notification process will be demonstrated at the State EOC. There will be no actual notification of licensed day cares.

A representative of the Division of Children Youth & Their Families will be available at the State EOC during the exercise for an interview.

Outstanding Issues: None 68

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Sub-element 3.d. - Implementation of Traffic and Access Control Intent This Sub-element is derived from NUREG-0654/FEMA-REP-1, which requires that OROs have the capability to implement protective action plans/procedures, including relocation and restriction of access to evacuated/sheltered areas. 'This Sub-element focuses on selecting, establishing, and staffing of traffic and access control points, and removal of impediments to the flow of evacuation traffic.

Criterion 3.d.1: Appropriate traffic and access control is established.' Accurate instructions are provided to traffic and access control personnel. (NUREG-0654/FEMA-REP-1, A.3; C.1,4; J.10.g,j)

Assessment/Extent of Play Assessment of this Demonstration Criterion may be accomplished during a full-scale or

. functional exercise, an actual event, or by means of drills conducted at any time.

OROs must demonstrate the capability to select, establish, and staff appropriate traffic and access control points consistent with current conditions and P ADs (e.g., evacuating,'sheltering, and relocation) in a timely manner. OROs must demonstrate the capability to provide instructions to traffic and access control staff on actions to take when modifications in protective action strategies necessitate changes in evacuation patterns or in the area(s) where access is controlled.

Traffic and access control staff must demonstrate accurate knowledge of their roles and responsibilities, including verifying emergency worker identification and access authorization to the affected areas, as per the Extent-of-Play Agreement. These capabilities may be demonstrated by actual deployment or by interview, in accordance with the Extent-of-Play Agreement.

In instances where OROs lack authority necessary to control access by certain types of traffic (e.g., rail, water, and air traffic), they must demonstrate the capability to contact the State or Federal agencies that have the needed authority, as agreed upon in the Extent-of-Play Agreement.

All activities must be based on the ORO's plans/procedures and completed as they would be in an actual emergency, unless noted above or otherwise specified in the Extent-of-Play Agreement.

Negotiated Extent of Play:

Evaluation of this criterion and related criteria for this demonstration (l.d.l, l.e. l, 3.a.l) will occur out of sequence on May 17, 2016. Demonstration will be by interview at the State EOC 69

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station between 6:00 p.m. and 7:00 p.m. in the parking lot of the State EOC. There will be no actual deployment of Access Control and Traffic Control Points. A list of equipment that would be used will be available for the evaluator.

Delaware State Police and Delaware Department of Transportation personnel will be interviewed on Traffic and Access Control procedures and will demonstrate communication system, as well as exposure control procedures. An emergency worker exposure briefing will be provided.

DSP and DelDOT personnel will simulate reporting to the Emergency Worker Decontamination Center CV olunteer Hose Company, Fire Substation) in Middletown, DE.

If directed, suiting in anti-contamination clothing and the ingestion of KI will be simulated.

Outstanding Issues: None 70

Radiological Emergency Preparedness (REP)/

Homeiand Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Criterion 3.d.2: Impediments to evacuation are identified and resolved. (NUREG-0654/FEMA-REP-1, J.10.k)

Assessment/Extent of Play Assessment of this Demonstration Criterion may be accomplished during a full-scale or functional exercise, an actual event, or by means of drills conducted at any time.

OROs must demonstrate the capability to identify and take appropriate actions concerning impediments to evacuations. In demonstrating this capability, the impediment must remain in place during the evacuation long enough that re-routing of traffic is required and must also result in demonstration of decision-making and coordination with the JIC to communicate the alternate route to evacuees. When, due to specifics of the scenario or jurisdiction, the impediment cannot be located on an evacuation route, it must be located so as to impact the evacuation. When not possible, actual dispatch ofresources need not be physically demonstrated; however, all contacts, actual or simulated, must be logged."

All activities must be based on the ORO's plans/procedures and completed as they would be in an actual emergency, unless noted above or otherwise specified in the Extent-of-Play Agreement.

Negotiated Extent of Play:

An Exercise inject will be provided by controllers regarding a road impediment/impediments.

If an evacuation is not part of the protective actions for this exercise, the demonstration will be done via interview.

Outstanding Issues: None 71

I I

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Sub-element 3.e - lmplemen!ation of Ingestion Pathway Decisions Intent This Sub-element is derived from NUREG-0654/FEMA-REP-1, which requires that OROs have the capability to implement protective actions, based on criteria recommended by current FDA guidance, for the ingestion exposure pathway EPZ (i.e., the area within an approximate 50-mile radius of the NPP). This Sub-element focuses on those actions required for implementation of protective actions.

Criterion 3.e.1: The ORO demonstrates the availability and appropriate use of adequate information regarding water, food supplies, milk, and agricultural production within the ingestion exposure pathway emergency planning zone/or implementation of protective actions. NUREG-0654/FEMA-REP-1, A.3; C.1, 4; J.11)

Assessment/Extent of Play Assessment of this Demonstration Criterion may be accomplished during a full-scale or functional exercise, an actual event, or by means of drills conducted at any time.

Applicable OROs must demonstrate the capability to secure and use current information on the locations of dairy farms, meat and poultry producers, fisheries, fruit growers, vegetable growers, grain producers, food processing plants, and water supply intake points to implement protective actions within the EPZ. OROs use Federal resources as identified in the NRF Nuclear/Radiological Incident Annex, and other resources (e.g., compacts, nuclear insurers), if available. Evaluation of this criterion will take into consideration the level of Federal and other resources participating in the exercise.

All activities must be based on the ORO's plans/procedures and completed as they would be in an actual emergency, unless noted above or otherwise specified in the Extent-of-Play Agreement.

Negotiated Extent of Play:

This criterion will not be evaluated for this exercise.

Outstanding Issues:

None 72

Radiological Emergency_ Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Criterion 3.e.2: Appropriate measures, strategies, and pre~printed instructional material are

  • developed for implementing protective action decisions for contaminated water, food products, milk, and agricultural production. (NUREG-0654/FEMA-REP-1, G;J, J.9, 11)

Assessment/Extent of Play Assessment of this Demonstration Criterion may be accomplishedduring a fall-scale or functional exercise, an actual event, or by means of drills conducted at any time.

OROs must demonstrate the development of measures and strategies for implementation of ingestion exposure pathway EPZ protective actions by formulating protective action information for the general public and food producers and processors. Demonstration of this criterion includes either pre-distributed public information material in the ingestion exposure pathway EPZ or the capability for rapid reproduction and distribution of appropriate reproduction-ready information and instructions to pre-determined individuals and businesses.

OROs must also demonstrate the capability to control, restrict, or prevent distribution of contaminated food by commercial sectors. Exercise play must include demonstration of communications and coordination among organizations to implement protective actions. Field play of implementation activities may be simulated. For example, communications and coordination with agencies responsible for enforcing food controls within the ingestion exposure pathway EPZ must be demonstrated, but actual communications with food producers and processors may be simulated.

All activities must be based on the ORO's plans/procedures and completed as they would be in an actual emergency, unless noted above or otherwise specified in the Extent-of-Play Agreement.

Negotiated Extent of Play:

This criterion will not be evaluated for this exercise.

Outstanding Issues:

None 73

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program,(REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Sub-element 3.f - Implementation of Post-Plume Phase Relocation, Reentry, and Return Decisions Intent This Sub-element is derived from NUREG-0654/FEMA-REP-1, which requires that OROs have the capability to implement plans, procedures, and decisions for post-plume phase relocation, reentry, and return. Implementation of these decisions is essential for protecting the public from direct long-term exposure to deposited radioactive materials from a severe incident at a commercial NPP.

Criterion 3.f.l: Decisions *regarding controlled reentry, relocation, and return of both emergency workers and the public during the post-plume phase are coordinated with appropriate organizations and implemented. (NUREG-0654/FEMA-REP-1, E. 7; J.JOJ; J.12; K.5.b; M.1, 3)

Assessment/Extent of Play Assessment of this Demonstration Criterion may be accomplished during a full-scale or functional exercise, an actual event, or by means of drills conducted at any time.

Relocation: OROs must demonstrate the capability to coordinate and implement decisions concerning relocation of individuals located in radiologically contaminated areas who were not previously evacuated. Such individuals must be relocated to an area(s) where radiological contamination will not expose the general public to doses that ex~eed the relocation PA Gs.

OROs must also demonstrate the capability to provide for short-or long-term relocation of evacuees who lived in an area(s) that has residual radiation levels above the (first-, second-, and 50-year) PAGs.

Areas of consideration must include the capability of OROs to communicate with other OROs regarding timing of actions, notification of the population of procedures for relocation, and notification of, and advice for, evacuated individuals who will be converted to relocation status in situations where they will not be able to return to their homes due to high levels of contamination. OROs must also demonstrate the capability to communicate instructions to the public regarding relocation decisions and intermediate-term housing for relocated persons.

Reentry: OROs must demonstrate the capability to control reentry and exit of individuals who are authorized by the ORO to temporarily reenter the restricted area during the post-plume (i.e.,

intermediate or late) phase to protect them from unnecessary radiation exposure. OROs must also demonstrate the capability to control exit of vehicles and other equipment to control the spread of contamination outside the restricted area(s). Individuals without specific radiological response missions, such as farmers for animal care, essential utility service personnel, or other m~mbers of the public who must reenter an evacuated area during the post-emergency phase*

74

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station must be limited to the lowest radiological exposure commensurate with completing their missions. Monitoring and decontamination facilities will be established as appropriate.

Examples of control procedures are: (1) assignment of, or checking for, direct-reading and permanent record dosimetry for emergency workers; (2) questions regarding the individuals' objective(s), location(s) expected to be visited, and associated timeframes; (3) maps and plots of radiation exposure rates; (4) advice on areas to avoid; (5) procedures for exit, including monitoring of individuals, vehicles, and equipment; (6) decision criteria regarding contamination; (7) proper disposition of emergency worker dosimetry, and (8) maintenance of emergency worker radiation exposure records.

Return: OROs must demonstrate the capability to implement policies concerning return of members of the public to areas that were evacuated during the plume phase. OROs must demonstrate the capability to identify and prioritize services and facilities that require restoration within a few days, and to identify procedures and resources for their restoration. Examples of these services and facilities are medical and social services, utilities, roads, and schools.

Communication among OROs for relocation, reentry, and return may be simulated., All simulated or actual contacts must be documented. These discussions may be accomplished in a group setting.

OROs must use Federal resources as identified in the NRF Nuclear/Radiological Incident Annex, and other resources (e.g., compacts or nuclear insurers), if available. Evaluation of this criterion will take into consideration the level of Federal and other resources participating in the exercise.

All activities must be based on the ORO's plans/procedures arid completed as they would be in an actual emergency, unless noted above or otherwise specified in the Extent-of-Play Agreement.

Negotiated Extent of Play:

This criterion will not be evaluated for this exercise.

Outstandinglssues: None 75

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station ASSESSMENT AREA 4: FIELD MEASUREMENTS AND ANALYSIS Sub-element 4.a - Plume Phase Field Measurements and Analyses Intent Ibis Sub-element is derived from NUREG-0654/FEMA-REP-1, which requires that OROs have*

the capability to deploy FMTs with the equipment, methods, and expertise necessary to determine the location of airborne radiation and particulate deposition on the ground from an

. airborne plume. In addition, NUREG-0654/FEMA-REP-1 indicates that OROs must have the capability to use FMTs within the plume exposure pathway EPZ to detect airborne radioiodine in the presence of noble gases and radioactive particulate material in the airborne plume. In an incident at an NPP, the possible release of radioactive material may pose a risk to the nearby population and environment. Although incident assessment methods are available to project the extent and magnitude of a release, these methods are subject to large uncertainties. During an incident, it is important to collect field radiological data to help characterize any radiological release. Adequate equipment and procedures are essential to such field measurement efforts.

Criterion 4.a.1: [RESERVED]

Criterion 4.a.2: Field teams (2.or more) are* managed to obtain sufficient information to help characterize the release and to control radiation, exposure. (NUREG-0654/FEMA-REP-1, C.1; H.12; L7, 8, 11; J.10.a)

Assessment/Extent of Play Assessment of this Demonstration Criterion may be accomplished during a full-scale, functional, or tabletop exercise. Other means may include drills, seminars or training activities that would fully demonstrate technical proficiency.

Responsible OR Os must demonstrate the capability to brief FMTs on predicted plume location and direction, plume travel speed, and exposure control procedures before deployment. During an RAB incident, the Field Team management must keep the incident command informed of field monitoring teams' activities and location. Coordination with FMTs and field monitoring may be demonstrated as out-of-sequence demonstrations, as negotiated in the Extent-of-Play Agreement.

Field measurements are needed to help characterize the release and support the adequacy of implemented protective actions, or to be a factor in modifying protective actions. Teams must be directed to take measurements at such locations and times as necessary to provide sufficient

  • information to characterize the plume and its impacts.

76

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station If the responsibility for obtaining peak measurements in the plume has been accepted by licensee field monitoring teams, with concurrence from OROs, there is no requirement for these measurements to be repeated by ORO monitoring teams. If the licensee FMTs do not obtain peak measurements in the plume, it is the ORO's decision as to whether peak measurements are necessary to sufficiently characterize the plume. The sharing and coordination of plume measurement information among all FMTs (licensee, Federal, and ORO) is essential.

OROs will use Federal resources as identified in the NRF Nuclear/Radiological Incident Annex and other resources (e.g., compacts or the licensee), as necessary. Evaluation of this criterion will take into consideration the level of Federal and other resources participating in the exercise.

All activities must be based on the ORO's plans/procedures and completed as they would be in an actual emergency, unless noted above or otherwise specified in the Extent-of-Play Agreement.

Negotiated Extent of Play:

All activities will be performed in accordance with the ORO's plans/procedures and completed as they would be in an actual emergency.

Outstanding Issues: None 77

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Criterion 4.a.3: Ambient radiation measurements are m.ade and recorded at appropriate locations, and radioiodine and particulate samples are collected. Teams will move to an appropriate low background location to determine whether any significant (as specified in the plan and/or procedures) amount of radioactivity has been collected on the sampling media.

(NUREG-0654/FEMA-REP-1, C.1; H.12: LB, 9; J.10.a)

Assessment/Extent of Play Assessment of this Demonstration Criterion may be accomplished during afull-scale,functional, or tabletop exercise. Other means may include drills, seminars or training activities that would

. fully demonstrate technical proficiency.

Two or more FMTs must demonstrate the capability to make and report measurements of ambient radiation to the field team coordinator, dose assessment team, or other appropriate*

authority. FMTs must also demonstrate the capability to obtain an air sample for measurement of airborne radioiodine and particulates, and to provide the appropriate authority with field data pertaining to measurement. If samples have radioactivity significantly above background, the authority must consider the need for expedited laboratory analyses of these samples.

Coordination concerning transfer of samples, including a chain-of-custody form(s), to a radiological laboratory(ies) must be demonstrated.

OROs must share data in a timely manner with all other appropriate OROs. All methodology, including contamination control, instrumentation, preparation of samples, and a chain-of-custody form(s) for transfer to a laboratory(ies), will be in accordance with the ORO's plans/procedures.

OROs will use Federal resources as identified in the NRF Nuclear/Radiological Incident Annex and other resources (e.g., compacts or the licensee), as needed. Evaluation of this criterion will take into consideration the level of Federal and other resources participating in the exercise.

All activities must be based on the ORO's plans/procedures and completed as they would be in an actual emergency, unless noted above or otherwise specified in the Extent-of-Play Agreement.

Negotiated Extent of Play:

Two (2) DNG Field Monitoring Teams (FMTs) will be evaluated.

Teams will demonstrate communication systems checks, equipment operability checks, inventory, and one member of one of the teams will demonstrate don/doff procedures with anti-contamination clothing at DNG Headquarters on May 17, 2016 (3:00 p.m.).

The DNG Field Teams will remain at the DNG Headquarters until activated. They will not be required to perform a second instrument checkout.when notified to deploy.

78

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station If directed, suiting in anti-contamination clothing and taking of Kl in the field will.be simulated.

DNG Field Monitoring Teams will simulate reporting to the Emergency Worker Decontamination Center in Middletown following completion of their assignment.

Each team will be directed to take an air sample in the plume, then analyze and report the results during the exercise as per REP Plan and procedures.

Delivery of samples for additional analysis will not be demonstrated. Chain of custody procedures will be described to the evaluator.

Outstanding Issues: None 79

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Sub-element 4.b-Post-Plume Phase Field Measurements and Sampling Intent This Sub-element is derived from NUREG-0654/FEMA-REP-1, which requires that OROs have the capability to assess the actual or potential magnitude and locations of radiological hazards to determine the ingestion exposure pathway EPZ and to support relocation, reentry, and return decisions. This Sub-element focuses on collecting environmental samples for laboratory analyses that are essential for decisions. on protecting the public from contaminated food and water and direct radiation from deposited materials.

Criterion 4.b.1: The field teams (2'or more) demonstrate the capability to make appropriate measurements and to collect appropriate samples (e.g.,food crops, milk, water, vegetation, and soil) to support adequate assessments and protective action decision making. (NUREG-0654/FEMA-REP-1, C.1; L8; J.11)

Assessment/Extent of Play Assessment of this Demonstration Criterion may be accomplished during a biennial or tabletop exercise. Other means may include drills, seminars or training activities that would fully demonstrate technical proficiency.

The ORO's FMTs must demonstrate the capability to take measurements and samples, at su~h times and locations as directed, to enable an adequate assessment of the ingestion pathway and to support reentry, relocation, and return decisions. When resources are available, use of aerial surveys and in-situ gamma measurement is appropriate. All methodology, including contamination control, instrumentation, preparation of samples, and chain-of-custody form(s) for transfer to a laboratory(ies), will be in accordance with the ORO's plans/procedures.

The FMTs and/or other sampling personnel must secure ingestion pathway samples from agricultural products and water. Samples in support of relocation and return must be secured from soil, vegetation, and other surfaces in areas that received radioactive ground deposition.

OROs will use Federal resources as identified in the NRF Nuclear/Radiological Incident Annex and other resources (e.g., compacts, the licensee, or nuclear insurers), as needed. Evaluation of this criterion will take into consideration the level of Federal and other resources participating in the exercise.

All activities must be based on.the ORO's plans/procedures and completed as they would be in an actual emergency, unless noted above or otherwise specified in the Extent-of-Play Agree~ent.

Negotiated Extent of Play: This criterion will not be evaluated for this exercise.

\\

80

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Outstandinglssues: None 81

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Sub-element 4.c - Laboratory Operations Intent This Sub-element is derived from NUREG-0654/FEMA-REP-1, which requires that OROs have the capability to perform laboratory analyses of radioactivity in air, liquid, and environmental samples to support protective action decision making.

Criterion 4.c.1: The laboratory is capable of performing required radiological analyses to support protective action decisions. (NUREG-0654/FEMA-REP-1, C.1, 3; J.11)

Assessment/Extent of Play Assessment of this Demonstration Criterion may be accomplished during a biennial, tabletop exercise, or an actual event. Other means may include drills, seminars or training activities that would fully demonstrate technical proficiency.

The laboratory staff must demonstrate the capability to follow appropriate procedures for receiving samples, including logging information, preventing contamination of the laboratory(ies ), preventing buildup of background radiation due to stored samples, preventing cross contamination of samples, preserving samples that may spoil (e.g., milk), and keeping track of sample identity. In addition, the laboratory staff must demonstrate the capability to prepare samples for conducting measurements.

The laboratory(ies) must be appropriately equipped to provide, upon request, timely analyses of media of sufficient quality and sensitivity to support assessments and decisions anticipated in the ORO's plans/procedures. The laboratory instrument calibrations must be traceable to standards provided by the National Institute of Standards and Technology. Laboratory methods used to analyze typical radionuclides released in a reactor incident must be as described in the plans/procedures. New or revised methods may be used to analyze atypical radionuclide releases (e.g., transuranics or as a result of a terrorist incident) or if warranted by incident circumstances.

Analysis may require resources beyond those of the ORO.

The laboratory staff must be qualified in radioanalytical techniques and contamination control procedures. OROs will use Federal resources as identified in the NRF Nuclear/Radiological Incident Annex and other resources (e.g., compacts, the licensee, or nuclear insurers), as needed.

Evaluation of this criterion will take into consideration the level of Federal and other resources participating in the exercise.

All activities must be based on the ORO's plans/procedures and completed as they would be in an actual emergency, unless noted above or otherwise specified in the Extent-of-Play Agreement.

Negotiated Extent of Play: This crl.terion will not be evaluated for this exercise.

82

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Outstanding Issues: None 83

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station ASSESSMENT AREA 5: EMERGENCY NOTIFICATION AND PUBLIC INFORMATION Sub-element 5.a - Activation of the Prompt Alert and Notification System Intent This Sub-element is derived from NUREG-0654/FEMA-REP-1, which requires that OROs have the capability to provide prompt instructions to the public within the plume exposure pathway EPZ. Specific provisions addressed in this Sub-element are derived from the Guide for the Evaluation of Alert and Notification Systems for Nuclear Power Plants, FEMA-REP-10 (November 1985).

5.a.l... covering essentially 100% of 10 mile EPZ 5.a.4... for FEMA-approved exception areas 5.a.3... covering the 10-mile EPZ x

x x

Criterion 5.a.1: Activities associated with primary alerting and notification of the public are completed in a timely manner following the initial decision by authorized of/site emergency officials to notify the public of an emergency situation. The initial instructional message to the public must include as a minimum the elements required by current REP guidance.

(NUREG-0654/FEMA-REP-1, E.5, 6, 7)

Assessment/Extent of Play Assessment of this Demonstration Criterion may be accomplished during a full-scale or functional exercise, drills, or operational testing of equipment that w*ould fully demonstrate capability.

Responsible OROs must demonstrate the capability to sequentially provide an alert signal followed by an initial instructional message to populated areas (permanent resident and transient) throughout the IO-mile plume EPZ. Following the decision to activate the alert and notification system, OROs must complete system activation for primary alert/notification and disseminate the 84

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station information/instructions in a timely manner. For exercise purposes, timely is defined as "with a

  • sense of urgency and without undue delay." If message dissemination is identified as not having been accomplished in a timely manner, the evaluator(s) will document a specific delay or cause as to why a message was not considered timely.

Procedures to broadcast the message must be fully demonstrated as they would in an actual emergency up to the point of transmission. Broadcast of the message(s) or test message(s) is not required. The procedures must be demonstrated up to the point of actual activation. The alert signal activation should be simulated, not performed. Evaluations ofEAS broadcast stations may also be accomplished through SA Vs.

The capability of the primary notification system to broadcast an instructional message on a 24-hour basis must be verified during an interview with appropriate personnel from the primary notification system, including verification of provisions foi: backup power or an alternate station.

The initial message must include at a minimum the following elements:

Identification of the ORO responsible and the official with authority for providing the alert signal and instructional message; Identification of the commercial NPP and a statement that an emergency exists there; Reference to REP-specific emergency information (e.g., brochures, calendars, and/or information in telephone books) for use by the general public during an emergency; and A closing statement asking that the affected and potentially affected population stay tuned for additional information, or that the population tune to another station for additional information.

If route alerting is demonstrated as a primary method of alert and notification, it must be done in accordance with the ORO's plans/procedures and the Extent-of-Play Agreement. OROs must demonstrate the capability to accomplish the primary route alerting in a timely manner (not subject to specific time requirements). At least one route needs to be demonstrated and evaluated. The selected route(s) must vary from exercise to exe~cise. However, the most difficult route(s) must be demonstrated no less than once every 8 years. All alert and notification activities along the route(s) must be simulated (that is, the message that would actually be used is read for the evaluator, but not actually broadcast) as negotiated in the extent of play. Actual testing of the mobile public address system will be conducted at an agreed-upon location.

OROs may demonstrate any means of primary alert and notification included in their plans/procedures as negotiated in the Extent-of-Play Agreement.

All activities must be based on the ORO's plans/procedures and completed as they would be in an.actual emergency, unless noted above or otherwise specified in the Extent-of-Play Agreement.

Negotiated Extent o(Plav:

Siren activation and broadcast of the EAS message will be simulated.

85

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Action Reportllmprovement Plan Radiological Emergency Preparedness Program (REP)

Salem and Hope Creek Nuclear Generating Station Alert and notification of the Delaware River area will be simulated.

Outstanding Issues: None 86

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Criterion 5.a.3: Backup alert and notification of the public is completed within a reasonable time following the detection by the ORO of a failure of the primary alert and notification system. (NUREG-0654/FEMA-REP-1, E.6, Appendix 3.B.2.c)

Assessment/Extent of Play Assessment of this Demonstration Criterion may be accomplished during a biennial exercise, drills, or operational testing of equipment that would fully demonstrate capability.

If the exercise scenario calls for.failure of any portion of the primary system(s) or if any portion of the primary system(s) actually fails to function during the exercise, OROs must demonstrate backup means of alert and notification. Backup means of alert and notification will differ from facility to facility.

Backup alert and notification procedures that would be implemented in multiple stages must be structured such that the population closest to the plant (e.g., within 2 miles) is alerted and notified first. The populations farther away and downwind of any potential radiological release would be covered sequentially (e.g., 2 to 5 miles, followed by downwind 5 to 10 miles, and finally the remaining population as directed by authorities). Topography, population density, existing ORO resources, and timing will be considered in judging the acceptability of backup means of alert and notification.

Although circumstances may not allow this for all situations, FEMA and the NRC recommend that OROs and operators attempt to establish backup means that will reach those in the plume exposure EPZ within a reasonable time of failure of the primary alert and notification system, with a recommended goal of 45 minutes. The backup alert message must, at a minimum, include (1) a statement that an emergency exists at the plant and (2) instructions regarding where to obtain additional information.

If backup route alerting is demonstrated, only one route needs to be selected and demonstrated. All alert and notification activities along the route(s) must be simulated (that is, the message that would actually be used is read for the evaluator, but not actually broadcast), as negotiated in the extent of play. Actual testing of the mobile public address system will be conducted at an agreed-upon location.

OROs may demonstrate any means of backup alert and notification included in their plans/procedures as negotiated in the Extent-of-Play Agreement.

All activities must be based on the ORO's plans/procedures and completed as they would be in an actual emergency, unless noted above or otherwise specified in the Extent-of-Play Agreement.

Negotiated Extent of Play: This criterion will not be evaluated for this exercise.

87

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Criterion 5.a.4: Activities associated with FEMA-approved exception areas (where applicable) are completed within 45 minutes following the initial decision by authorized offsite emergency officials to notify the public of an emergency situation. (NUREG-0654/FEMA-REP-,1, E.6; Appendix 3.B.2.c)

Assessment/Extent of Play Assessment of this Demonstration Criterion may be accomplished during a biennial exercise, drills, or operational testing of equipment that would fully demonstrate capability.

OROs with FEMA-approved exception areas (identified in the approved Alert and Notification System Design Report), 5 to 10 miles from the NPP, must demonstrate the capability to accomplish primary alerting and notification of the exception area(s). FEMA and the NRC recommend that OROs and operators establish means that will reach those in approved exception areas within 45 minutes once the initial decision is made by authorized offsite emergency officials to notify the public of an incident. The exception area alert message must, at a minimum, include (1) a statement that an emergency exists at the plant and (2) instructions regarding where to obtain additional information.

For exception area alerting, at least one route must be demonstrated and evaluated. The selected route(s) must vary from exercise to exercise. However, the most difficult route(s) must be demonstrated no less than once every 8 years. All alert and notification activities along the route(s) must be simulated (that is, the message that would actually be used is read for the evaluator, but not actually broadcasted) as negotiated in the extent of play. Actual testing of the mobile public address system will be conducted at an agreed-upon location. For exception areas alerted by air/water craft, actual routes will be negotiated in the extent of play, but must be demonstrated no less tJ;ian once every 8 years.

All activities must be based on the ORO's plans/procedures and completed as they would be in an actual emergency, unless noted above or otherwise specified in the Extent-of-Play j\\greement.

Negotiated Extent of Play:

Criterion does not apply - there are no exception areas in the State ofDelaware Sub-element 5.b - Subsequent Emergency Information and Instructions for the Public and the Media Intent This Sub-element is derived from NUREG-0654/FEMA-REP-l, which requires that OROs have the capability to disseminate appropriate emergency information and instructions, including any recommended protective actions, to the public. In addition, NUREG-0654/FEMA-REP-1 89

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station requires OROs to ensure that the capability exists for providing information to the media. This includes the availability of a physical location for use by the media during an emergency.

NUREG-0654/FEMA-REP-1 also provides that a system must be available for dealing with rumors. This system will hereafter be known as the public inquiry hotline.

Criterion 5.b.1: OROs provide accurate subsequent emergency information and instructions to the public and the news media in a timely manner. (NUREG-0654/FEMA-REP-1, E.5, 7; G.3.a, G.4.a, c)

Assessment/Extent of Play Assessment of this Demonstration Criterion may be accomplished during a full-scale or functional exercise, or drills.

The emergency information must be all-inclusive by including the four items specified under exercise Demonstration Criterion 5.a. I and previously identified protective _action areas that are still valid, as well as new areas. Information about any rerouting of evacuation routes due to impediments should also be included._ The OROs must demonstrate the capability to ensure that emergency information that is no longer valid is rescinded and not repeated by broadcast media.

Message elements: The ORO must ensure that emergency information and instructions are consistent with P ADs made by appropriate officials. The emergency information must contain all necessary and applicable instructions (e.g., evacuation instructions, evacuation routes, reception center locations, what to take when evacuating, shelter-in-place instructions, information concerning protective actions for schools and persons with disabilities and access/functional needs, and public inquiry hotline telephone number) to assist the public in carrying out the P ADs provided. The ORO must also be prepared to disclose and explain the ECL of the incident. At a minimum, this information must be included in media briefings and/or media releases. OROs must demonstrate the capability to use language that is clear and understandable to the public within both the plume and ingestion exposure pathway EPZs. This includes demonstration of the capability to use familiar landmarks and boundaries to describe protective action areas.

The emergency information must be all-inclusive by including the four items specified under exercise Demonstration Criterion 5.a.l and previously identified protective action areas that are still valid, as well as new areas. The OROs must demonstrate the capability to ensure that emergency information that is no longer valid is rescinded and not repeated by broadcast media..

In addition, the OROs must demonstrate the capability to ensure that current emergency information is repeated at pre-established intervals in accordance with the plans/procedures.

OROs must demonstrate the capability to develop emergency information in a non-English language when required by the plans/procedures.

90

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station If ingestion pathway measures are exercised, OROs must demonstrate that a system exists for rapid dissemination of ingestion pathway information to pre-determined ind_ividuals and businesses in accordance with the ORO's plans/procedures.

Media information: OROs must demonstrate the capability to provide timely, accurate, concise, and coordinated information to the news media for subsequent dissemination to the public. This would include demonstration of the capability to conduct timely and pertinent media briefings and distribute media releases as the incident warrants. The OROs must demonstrate the capability to respond appropriately to inquiries from the news media. All information presented in media briefings and releases must be consistent with P ADs and other emergency information provided to the public. Copies of pertinent emergency information (e.g., EAS messages and media releases) and media information kits must be available for dissemination to the media.

Public inquiry: OROs must demonstrate that an effective system is in place for dealing with calls received via the public inquiry hotline. Hotline staff must demonstrate the capability to provide or obtain accurate information for callers or refer them to an appropriate information source. Information from the hotline staff, including information that corrects false or inaccurate information when trends are noted, must be included, as appropriate, in emergency information provided to the public, media briefings, and/or media releases.

RAB considerations: The dissemination of information dealing with specific aspects ofNPP security capabilities, actual or perceived adversarial (terrorist) force or threat, and tactical law enforcement response must be coordinated/communicated with appropriate security authorities, e.g., law enforcement and NPP security agencies, in accordance with ORO plans/procedures.

All activities must be based on the ORO's plans/procedures and completed as they would be in an actu~ emergency, unless noted above or otherwise specified in the Extent-of-Play Agreement.

Negotiated Extent of Play:

Press releases and EAS messages are written and approved at the State EOC. Actual broadcast ofEAS messages will be simulated. The Emergency News Center (ENC) lead, Woodstown, NJ disseminates this information at the ENC. At least one media briefing will be conducted. Public inquiry calls will be initiated. Public inquiry at the State EOC will be staffed with two operators and will receive at least six calls to include at least two (2) identifiable trends.

Outstanding Issues: None 91

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report!lmprovement Plan Salem and Hope Creek Nuclear Generating Station ASSESSMENT AREA 6: SUPPORT OPERATIONS/FACILITIES Sub-element 6.a -Monitoring, Decontamination, and Registration of Evacuees.

Intent This Sub-element is derived from NUREG-0654/FEMA-REP-1, which requires that OROs have the capability to implement radiological monitoring and decontamination of evacuees, while minimizing contamination of the facility. OROs must also have the capability to identify and register evacuees at reception centers.

Criterion 6.a.1: The reception center facility has appropriate space, adequate resources, and trained personnel to provide monitoring, decontamination, and registration of evacuees.

(NUREG-0654/FEMA-REP-1, A.3; C.4; J.10.h; J.12)

Assessment/Extent of Play.

Assessment of this Demonstration Criterion may be accomplished during a biennial exercise, an actual event, drills, or SA V.

Radiological monitoring, decontamination, and registration facilities for evacuees must be set up and demonstrated as they would be in an actual emergency or as indicated in the Extent-of-Play

  • Agreement. OROs conducting this demonstration must have one-third of the resources (e.g.,

. monitoring teams/instrumentation/portal monitors) available at the facility(ies) as necessary to monitor 20 percent of the population within a 12-hour period. This would include adequate space for evacuees' vehicles. Availability of resources can* be demonstrated with valid documentation (e.g., MOU/LOA, etc.) reflecting how necessary equipment would be procured for the location. Plans/procedures must indicate provisions for service animals.

Before using monitoring instrument(s), the monitor(s) must demonstrate the process of checking the instrument(s) for proper operation. Staff responsible for the radiological monitoring of evacuees must demonstrate the capability to attain and sustain, within about 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, a monitoring productivity rate per hour needed to monitor the 20 percent EPZ population planning base. The monitoring productivity rate per hour is the number of evacuees that can be

  • monitored, per hour, by the total complement of monitors using an appropriate procedure. For demonstration of monitoring, decontamination, and registration capabilities, a minimum of six evacuees must be monitored per station using equipment and procedures specified in the plans/procedures. The monitoring sequences for the first six simulated evacuees per monitoring team will be timed by the evaluators *to determine whether the 12-hour requirement can be met.

OROs must demonstrate the capability to register evacuees upon completion of the monitoring and decontamination activities. The activities for recording radiological monitoring and, if necessary, decontamination must include establishing a registration record consisting of the evacuee's name, address, results of monitoring, and time of decontamination (if any), or as

. 92

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station otherwise designated in the plan and/or procedures. Audio recorders, camcorders, or written records are all acceptable means for registration.

Monitoring activities shall not be simulated. Monitoring personnel must explain use of trigger/action levels for determining the need for decontamination. They must also explain the procedures for referring any evacuees who cannot be adequately decontaminated for assessment and follow-up in accordance with the ORO's plans/procedures. All activities must be based on the ORO's plans/procedures and completed as they would be in an actual emergency, unless noted above or otherwise specified in the Extent-of-Play Agreement.

Decontamination of evacuees may be simulated and conducted by interview. Provisions for separate showering and same-sex monitoring must be demonstrated or explained. The staff must demonstrate provisions for limiting the spread of contamination. Provisions could include floor coverings, signs, and appropriate means (e.g., partitions, roped-off areas) to separate uncontaminated from potentially contaminated areas. Provisions must also exist to separate contaminated and uncontaminated evacuees, provide changes of clothing for those with contaminated clothing; and store contaminated clothing and personal belongings to prevent further contamination of evacuees or facilities. In addition, for any evacuee found to be contaminated, procedures must be discussed concerning handling of potential contamination of vehicles and personal belongings. Waste water from decontamination operations does not need to be collected.

Individuals who have completed monitoring (and decontamination, ifneeded) must have means (e.g., hand stamp, sticker, bracelet, form, etc.) indicating that they, and their service animals and vehicles, where applicable, have been monitored, cleared, and found to have no contamination or contamination below the trigger/action level or have been placed in a secure area until they can be monitored and decontaminated, if necessary.

In accordance with plans/procedures, individuals found to be clean after monitoring do not need to have their vehicle monitored. These individuals do not require confirmation that their vehicle is free from contamination prior to entering the congregate care areas.

However, those individuals who are found to be contaminated and are then decontaminated will have their vehicles held in a secure area or monitored and decontaminated (if applicable) and do reqµire confirmation that their vehicle is being held in a secure area or free from contamination prior to entering the congregate care areas.

Negotiated Extent of Play:

Evaluation ofthis criterion and related criteria for this demonstration (l.e.l, 3.a.l, 3.b.l) will occur out of sequence on April 21, 2016 at 9: 00 am at the Stem Readiness Center.

Outstandinglssues: None 93

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Sub-element 6.b-Monitoring and Decontamination of Emergency Workers and their Equipment and Vehicles Intent This Sub-element is derived from NUREG-0654/FEMA-REP-1, which requires that OROs have the capability to implement radiological monitoring and decontamination of emergency workers and their equipment, inclusive ofveliicles.

Criterion 6.b.1: The facility/ORO has adequate procedures and resources to accomplish monitoring and decontamination of emergency workers and their equipment and vehicles.

(NUREG-0654/FEMA-REP-1, K.5.a, b)

Assessment/Extent of Play Assessment of this Demonstration Criterion may be accomplished during a biennial exercise, drills, an actual event, or SA V.

The monitoring staff must demonstrate the capability to monitor emergency worker personnel and their equipment and vehicles for contamination in accordance with the ORO's plans/procedures.

Specific attention must be given to equipment, including any vehicles that were in contact with contamination. The monitoring staff must demonstrate the capability to make decisions on the need for decontamination of personnel, equipment, and vehicles based on trigger/action levels and procedures stated in the ORO plans/procedures. Monitoring of emergency workers does not have to meet the 12-hour requirement. However, appropriate monitoring procedures must be demonstrated for a minimum of two emergency workers and their equipment arid vehicles.

Before using monitoring instrument(s), the monitor(s) must demonstrate the process of checking the instrument(s) for proper operation.

The area to be used for monitoring and decontamination must be set up as it would be in an actual emergency, with all route markings, instrumentation, record keeping, and contamination control measures in place. Monitoring procedures must be demonstrated for a minimum of one vehicle. It is generally not necessary to monitor the entire surface of vehicles. However, the capability to monitor areas such as radiator grills, bumpers, wheel wells, tires, and door handles must be demonstrated. Interior surfaces of vehicles that were in contact with contaminated individuals must also be checked.

Decontamination of emergency workers may be simulated and conducted via interview.

Provisions for separate.showering and same-sex monitoring must be demonstrated or explained.

The staff must demonstrate provisions for limiting the spread of contamination. Provisions could include floor coverings, signs, and appropriate means (e.g., partitions, roped-off areas) to 94

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station separate uncontaminated from potentially contaminated areas. Provisions must also exist to separate contaminated and uncontaminated individuals where applicable; provide changes of clothing for those with contaminated clothing; and store contaminated clothing and personal belongings to prevent further contamination of emergency workers or facilities.

Monitoring activities shall not be simulated. Monitoring personnel must explain use of trigger/action levels for determining the need for decontamination. They must also explain the procedures for referring any emergency workers who cannot be adequately decontaminated for assessment and follow-up in accordance with the ORO's plans/procedures.

Decontamination capabilities and provisions for vehicles and equipment that cannot be successfully decontaminated may be simulated and conducted by interview. Waste water from decontamination operations does not need to be collected.

All activities must be based on the ORO's plans/procedures and completed as they would be in an actual emergency, unless noted above or otherwise specified in the Extent-of-Play Agreement.

Negotiated Extent of Play:

This criterion will not be evaluated for this exercise.

Outstanding Issues: None 95

r-i L

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Sub-element 6.c - Temporary Care of Evacuees Intent This Sub-element is derived from NUREG-0654/FEMA-REP-1, which requires OROs to have the capability to establish relocation centers in host/support jurisdictions. The American Red Cross normally provides congregate care in support of OROs under existing letters of agreement.

Criterion 6.c.1: Managers of congregate care facilities demonstrate that the centers have resources to provide services and accommodations consistent with American Red Cross planning guidelines. Managers demonstrate the procedures to assure that evacuees have been monitored/or contamination and have been decontaminated as appropriate prior to entering congregate care facilities. (NUREG-0654/FEMA-REP-1, J.10.h, J.12)

  • Assessment/Extent of Play Assessment of this Demonstration Criterion may be accomplished during a biennial exercise, drills, an actual event, or SA V.

The evaluator must conduct a walk-through of the center to determine, through observation and inquiries, that the services and accommodations are consistent with applicable guidance.

For planning purposes, OROs must plan for a sufficient number of congregate care centers in host/support jurisdictions based on their all-hazard sheltering experience and what is historically relevant for that particular area. In this simulation, it is not necessary to set up operations as they would be in an actual emergency. Alternatively, capabilities may be demonstrated by setting up stations for various services and providing those services to simulated evacuees. Given the substantial differences between demonstration and simulation of this criterion, exercise demonstration expectations must be clearly specified in Extent of-Play Agreements.

Congregate care staff must also demonstrate the capability to ensure that evacuees, service animals, and vehicles have been monitored for contamination, decontaminated as appropriate, and registered before entering the facility.

Individuals arriving at congregate care facilities must have means (e.g., hand stamp, sticker, bracelet, form, etc.) indicating that they, and their service animals and vehicles, where applicable, have been placed in a secured area or monitored, cleared, and found to have no contamination or contamination below the trigger/action level.

In accordance with plans/procedures, individuals found to be clean after monitoring do not need to have their vehicle monitored. These individuals do not need confirmation that their vehicle is free from contamination prior to entering the congregate care areas.

96

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Action Report/Improvement Plan Radiological Emergency Preparedness Program (REP)

Salem and Hope Creek Nuclear Generating Station However, those individuals who are found to be contaminated and are then decontaminated will have their vehicles held in a secure area until they can be monitored and decontaminated (if applicable) and do need confirmation that their vehicle is being held in a secure area or free from contamination prior to entering the congregate care areas. This capability may be determined through an interview process.

If operations at the center are demonstrated, material that would be difficult or expensive to transport (e.g., cots, blankets, sundries, and large-scale food supplies) need not be physically available at the facility(ies). However, availability of such items must be verified by providing the evaluator a list of sources with locations and estimates of quantities.

All activities must be based on the ORO's plans/procedures and completed as they would be in an actual emergency, unless noted above or otherwise specified in the Extent-of-Play Agreement.

Negotiated Extent of Play:

This criterion will not be evaluated for this exercise.

Outstandinglssues: None 97

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station Sub-element 6.d..:.... Transportation and Treatment of Contaminated Injured Individuals Intent This Sub-element is derived from NUREG-0654/FEMA-REP-1, which requires that OROs have*

the capability to transport contaminated injured individuals to medical facilities with the capability to provide medical services.

Criterion 6.d.1: The facility/ORO has the appropriate space, adequate resources, and trained personnel to provide transport, monitoring, decontamination, and medical services to contaminated injured individuals. (NUREG-0654/FEMA-REP-1, F.2; H.10; K.5.a, b; L.1, 4)

Assessment/Extent of Play Assessment of this Demonstration Criterion may be accomplished during a biennial exercise, an actual event or drills. FEMA has determined that these capabilities have been enhanced and consistently demonstrated as adequate; therefore, offsite medical services drills need only be evaluated biennially. FEMA will, at the request of the involved ORO, continue to evaluate the drills on an annual basis. All hospitals listed in the plan as medical services hospitals must be evaluated, with a transportation provider, every 2 years. Additional transportation providers will be rotated through the drills in the 8-year exercise cycle. For ambulance providers who do not participate in an evaluated drill during the two year cycle, training will be provided. This training will be documented in the ALC."

Monitoring, decontamination, and contamination control efforts must not delay urgent medical care for the victim.

OROs must demonstrate the capability to transport contaminated injured individuals to medical facilities.

An ambulance must be used for response to the victim. However, to avoid taking an ambulance out of service for an extended time, OROs may use any vehicle (e.g., car, truck, or van) to transport the victim to the medical facility. It is allowable for an ambulance to demonstrate up to the point of departure for the medical facility and then have a non-specialized vehicle transport the "victim(s)" to the medical facility. This option is used in areas where removing an ambulance from service to drive a great distance (over an hour) for a drill would not be in the best interests of the community.

Normal communications between the ambulance/dispatcher and the receiving medical facility must be demonstrated. If a substitute vehicle is used for transport to the medical facility, this communication must occur before releasing the ambulance from the drill. This communication would include reporting radiation monitoring results, if available. In addition, the ambulance 98

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station crew must demonstrate, by interview, knowledge of where the ambulance and crew would be monitored and decontaminated, if required, or whom to contact for such information.

Monitoring of the victim may be performed before transport or en route, or may be deferred to the medical facility. Contaminated injured individuals transported to medical facilities are monitored as soon as possible to assure that everyone (ambulance and medical facility) is aware of the medical and radiological status of the individual(s). However, if an ambulance defers monitoring to the medical facility, thenthe ambulance crew presumes that the patient(s) is contaminated and demonstrate appropriate contamination controls until the patient(s) is monitored. Before using monitoring instruments, the monitor( s) must demonstrate the process of checking the instrument(s) for proper operation. All monitoring activities must be completed as they would be in an actual emergency. Appropriate contamination control measures must be demonstrated before and during transport and at the receiving medical facility.

The medical facility must demonstrate the capability to activate and set up a radiological emergency ar~a for treatment. Medical facilities are expected to have at least one trained physician and one trained nurse to perform and supervise treatment of contaminated injured individuals. Equipment and supplies must be available for treatment of contaminated injured individuals.

The medical facility must demonstrate the capability to make decisions on the need for decontamination of the individual, follow appropriate decontamination procedures, and maintain records of all survey measurements and samples taken. All procedures for collection and analysis of samples and decontamination of the individual must be demonstrated or described to the evaluator. Waste water from decontamination operations must be handled according to facility plans/procedures.

All activities must be based on.the ORO's plans/procedures and completed as they would be in an actual emergency, unless noted above or otherwise specified in the Extent-of-Play Agreement.

State Negotiated Extent of Play:

Evaluation of this criterion and related criteria for this demonstration (l.e.1, 3.a.1, 6.d.1) will occur out of sequence on May 6, 2016 at 9:00 am at Christiana Hospital with patient transport demonstrated by Delaware City EMS at 9:00 am. The incident site will be at the DART Wrangle Hill Road Facility, 2101 Mid County Drive, New Castle, Delaware 19720 (intersection of SR 72 and US 13)

Outstanding Issues: None 99

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station REP MANUAL DEMONSTRATION CRITERIA FREQUENCY MATRIX (7/2015)1 A. I.a, e; A.3, 4; YES YES NO C.I, 4, 6; D.4; E.I, 2; H.3, 4 G.3.a; H.3; J.10.h, J.12; YES YES YES K.5.b I.c. I: Key personnel with leadership roles for the ORO provide direction and control to that part of A. l.d; A.2.a, b; At least the overall response effort for which they are A.3; C.4, 6 biennially NO NO responsible.

I.d. I: At least two communication systems are available, at least one operates properly, and communication links are established and maintained At least with appropriate locations. Communications F.I, 2 biennially YES3 NO NO capabilities are managed in support of emergency operations.

  • H.7, IO;I.7,8, 9; J.10.a, b, e; At least J.11, 12; K.3.a; biennially K.5.b l\\:j'EEi~it,l~{E~*<B:lfi9 "er'*ett'~wm:Rer'Ex 2.a.1: OROs use a decision-making process, considering relevant factors and appropriate coordination, to ensure that an exposure control system, including use of Kl, is in place for C.6; J.10.e, f; At least NO NO NO emergency workers, including provisions to K.3.a; K.4 biennially authorize radiation exposure in excess of administrative limits or PA Gs.

1 See NUREG-0654/FEMA-REP-l Criteria N.l.b and N.l.d for additional details 2 Facilities evaluated once when they are new and once every 8 years thereafter. Facilities are re-evaluated for this criterion if, in the interim since the last evaluation, they have substantial changes in structure, equipment, or mission that affect key capabilities, as outlined in emergency plans/procedures.

3 Communications equipment can be demonstrated in an out-of-sequence scenario during medical services and reception/relocation center drills as negotiated in the extent of play.

100

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nnclear Generating Station 2.b.2: A decision-making process involving consideration of appropriate factors and necessary coordination is used to make P ADs for the general public (including the recommendation for use of KI, if ORO policy).

2.c.1: PADs are made, as appropriate, for groups of people with disabilities and those with access/ functional needs.

2.d. l: Radiological consequences for the ingestion pathway are assessed and appropriate P ADs are made based on the ORO planning criteria.

2.e.1: Timely post-plume phase relocation, re-entry, and return decisions are made and coordinated as appropriate, based on assessments of radiological conditions and criteria in the ORO's plan and/or procedures.

'.,a~:!:ctncJ¢m~ri: JicinW1f :Em:et en:~~xw:<>Hi'.r:Ex' 3.a.1: The OROs issue appropriate dosimetry, KI, and procedures, and manage radiological exposure to emergency workers in accordance with the plans/procedures.

I.10; Supp.3 A.3; C.4, 6; D.4; J.9; J.10.f, rn D.4; J.9; J.10.d, e A.3; C.l, 4; D.4; J.9, 11 I.10; J.9; K.3.a; M.1 Emergency workers periodically and at the end of each mission read their dosimeters and J. lO.e; K.3.a, record the readings on the appropriate b; K.4 exposure record or chart. Appropriate record-keeping of the administration of KI for emergency workers is maintained.

At least biennially At least biennially At least biennially Every ingestion exercise No less than once every 8 years At least biennially NO NO NO NO NO NO NO NO NO NO YES NO 4 The post-plume phase (ingestion, relocation, re-entry, and return) may be demonstrated separately from the plume phase.

101 NO NO NO NO NO NO

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified

' Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station

6'.t
;;_t' 3.b.I
KI and appropriate instructions are made available in case a decision to recommend use of KI is made. Appropriate record keeping of the administration of KI for J.lO.e, f institutionalized individuals and the general ublic is maintained.

At least biennially5 YES NO NO

~1~t:iriil 1

lementation:D't~r9f~ctl've:r;rctllifis'ftor::Btfrs'i>nsHVit&ni§a6itffiesr!lna~~ccessmiinc'tl'Ori~i;:Nee~#t0~;;*;0°~t!~;r~?;!J~,~'\\1~s2:'}~0 3.c. l: P ADs are implemented for people with disabilities and those with access/functional needs othei; than schools within areas subject J.lO.c, d, e, g to rotective actions.

No less than once every 8 years 3.c.2: OROs/school officials implement No less than protective actions for schools.

J.10.c, d. e. g once every 8 years6 3.d.l: Appropriate traffic and access control is established. Accurate instructions are provided to traffic and access control ersonnel.

A.3; C.l, 4; J.10.g,j At least biennially YES YES YES YES YES

'YES YES YES YES 3.d.2: Impediments to evacuation are At least YES YES YES identified and resolved.

J.lO.k biennially 3.e. l: The ORO demonstrates the availability and appropriate use of adequate information regarding water, food supplies, milk, and agricultural production within the ingestion exposure pathway emergency planning zone for implementation of protective actions.

3.e.2: Appropriate measures, strategies, and pre-printed instructional material are developed for implementing P ADs for contaminated water, food products, milk, and agricultural production.

A.3; C.l, 4; J.11 G.l, J.9, 11 Every ingestion exercise Every ingestion exercise YES YES NO NO NO NO 1~t~1inlelil'~a'tit~10:li\\tot,~:&st*Jt1µQ1e::~l!'ase<iR:ei~<+/-ati-On;:Re?enr:;11tn&~ef:uH1f:n'ee1Si9'n~it11:11j')i~~?:w'~i:~~~;~~~:,,l'icti\\\\fil~~?~~1)1~?;~~!it£i~*'

3.f.1: Decisions regarding controlled re-entry, relocation, and return of individuals during the post-plume phase are coordinated with appropriate organizations and implemented.

E.7; J.10.j; J.12; K.5.b; M.1;3 No less than once every 8 years YES NO NO 5 Demonstrated in every biennial exercise. Participation may be rotated among facilities, but each individual distribution facility must be evaluated no less than once every 8 years.

6 Participation may ~e rotated among school districts, 'but each school system/district in the EPZ and at least one of its schools must be evaluated no less than once every 8 years. It is not required that every fohool within the school system/district be evaluated.

7 Physical deployment of resources is not necessary except in a full-scale exercise 102

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Salem and Hope Creek Nuclear Generating Station 4.al: (RESERVED) 4.a.2: Field teams (two or more) are managed to obtain sufficient information to help characterize the release and to control radiation exposure.

4.a.3: Ambient radiation measurements are made and recorded at appropriate locations, and radioiodine and particulate samples are collected.

Teams will move to an appropriate low-background location to determine whether.any significant (as specified in the plan and/or procedures) amount of radioactivity has been collected on the sampling media.

4.b. l: The field teams (two or more) demonstrate the capability to make appropriate measurements C.l; H.12; 1.7, 8, 11; J.10.a C.l; I.8, 9; H.12; J.10.a Every full participation exercise8 Every full participation exercise and collect samples (e.g., food crops, milk, water, C.l; Every.

YES YES vegetation, and soil) to support adequate I.8; ingestion YES assessments and protective action decision-J.11 exercise making.

4.c.l: The laboratory is capable of performing required radiological analyses to support P ADs.

C.l, 3; J.11

~:5~'.Fi '

1~.t~'Nf5}Jl,UJitlJ~~INFOEMt\\$IO., "' **

  • 'a'i':A~tivatio

.itin'a:.N&tmt:liifoli:s**sti:lm't:~;~,i.ii; 5.a 1: Activities associated with primary alerting and notification of the public are completed in a timely manner following the initial decision by authorized offsite emergency officials to notify the

  • public of an emergency situation. The initial instructional message to the public must include as a minimum the elements required by current REP guidance.

5.a.2: (RESERVED) 5.a.3: Backup alert and notification of the public is completed within a reasonable time following detection by the ORO of a failure of the primary alert and notification system.

E.5, 6, 7 E.6; Appendix 3.B.2.c At least biennialzy No less than once every 8 years YES YES NO NO NO NO NO NO NO NO NO NO 8 Each state within the 10-mile EPZ of a commercial nuclear power site shall fully participate in an exercise jointly with the licensee and appropriate OROs at least every 2 years (44 CFR Part 350.9 (c)(l)). Each state with multiple sites within its boundaries shall fully participate in a joint exercise at some site on a rotational basis at least every 2 years (44 CFR Part 350.9 (c)(2)). When not fully participating in an exercise at a site, the state shall partially participate at the site to support full participation of the OROs. See NUREG-0654/FEMA-REP-l Criterion N.l.b for clarification of full participation.

103

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station 5.a.4: Activities associated with FEMA approved exception areas (where applicable) are completed within 45 minutes of the initial decision by authorized offsite emergency officials to notify the public of an emergency situation.

E.6; Appendix At least 3.B.2.c biennially 5.b.I: OROs provide accurate emergency information and instructions to the public and news E.5, 7; G.3.a; media in a timely manner.

G.4.a, c At least biennially No less than YES YES A.3; C.4; J.10.h; J.12 once every 8 YES years9 NO NO NO NO YES NO i'.*6~:*.Monitofilt'tranil;J1ecoDtamlnatto'IJ'JiNtmef~eni':'*xworkersan'd'.,ilieir:*:E ***lit *m~ilt:ianli:V'ehfci¢S.Gi\\t':::;0;::;,r;i*ff;t~\\\\il1*l~?c, ;';,;;,,.,

6.b. l: The facility/ORO has adequate procedures and resources to accomplish monitoring and No less than decontamination of emergency workers and their K.5.a, b once every 8 YES YES NO equipment and vehicles.

years 6.c. l: Managers of congregate care facilities demonstrate that the centers have resources to provide services and accommodations consistent with planning guidelines. Managers demonstrate the procedures to assure that evacuees have been monitored for contamination and have been decontaminated as appropriate before entering congregate care facilities.

6.d.l: The facility/ORO has the appropriate space, adequate resources, and trained personnel to provide transport, monitoring, decontamination, and medical services to contaminated injured individuals.

J.10.h; J.12 F.2; H.10; K.5.a, b; L.1, 4 No less than once every 8 YES years10 At least biennially YES 9 Participating may be rotated among facilities, but each facility must be evaluated no less than once every 8 years.

YES YES YES NO 1° Facilities managed by the American Red Cross under the American Red Cross/FEMA MOU will be evaluated once when designated or when substantial changes occur; all other facilities not managed by the American Red Cross must be evaluated no Jess than once every 8 years.

104

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan Addresses of Locations to be Evaluated State State Emergency Operations Center (EOC)

State Technical Assessment Center (TAC) 165 Brick Store Landing Rd Smyrna, DE 19977 Salem and Hope Creek Nuclear Generating Station Emergency News Center/Joint Information Center (ENC/JIC) 13 5 Cemetery Rd Woodstown, NJ 08098 Delaware National Guard (DNG) Field Teams - DNG HQ 1 Regiment Rd Wilmington, DE 19808 Counties New Castle County EOC 3601 N DuPont Hwy New Castle, DE 19720 Kent County EOC 911 Public Safety Blvd Dover, DE 19901 Out of Sequence Demonstrations School District and School Appoquinimink School District 313 South 5th Street Odessa Park Building Odessa, DE 19730 Alfred G. Waters Middle School 1235 Cedar Lane Rd, Middletown, DE 19709 105

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Preparedness Program (REP)

Action Report/Improvement Plan

  • Addresses of Locations to be Evaluated (CONTINUED)

Transportation Dependent Staging Area: DART Wrangle Hill Road Facility 2101 Mid County Drive, New Castle, Delaware 19720 (Intersection of SR 72 and US 13)

Reception Center Stem Readiness Center Delaware National Guard 1401 Newport Gap Pike Wilmington, DE EMS:

Delaware City Fire Company (patient transport)

Incident Location:

DART Wrangle Hill Road Facility, 2101 Mid County Drive, New Castle, Delaware 19720 (Intersection of SR 72 and US 13)

Hospital:

Christiana Care 4755 Ogletown-Stanton Road, Newark, DE 19718 Room 1E80, adjacent to Emergency Department 106 Salem and Hope Creek Nuclear Generating Station

Radiological Emergency Preparedness (REP)/

Homeland Security Exercise and Evaluation Program (HSEEP)

Unclassified Radiological Emergency Prepared11ess Program (REP)

Action Report/Improvement Plan Salem and Hope Creek Nuclear Generating Station OPEN FINDINGS None 107