1 NRR-PMDAPEm Resource From:
Chawla, Mahesh Sent:
Friday, June 17, 2016 4:38 PM To:
Woyak, Bryan (Bryan.Woyak@nexteraenergy.com); Locke, Kim (Kim.Locke@nexteraenergy.com); michael.millen@nexteraenergy.com Cc:
Wrona, David; Hardgrove, Matthew; Oesterle, Eric; Nold, David; West, Khadijah; Parillo, John; Sweat, Tarico; Edmonds, Shavon
Subject:
Request for Additional Information - Point Beach, Units 1 & 2 - License Amendment Request - Removal of Completed License Conditions and Change to the Ventilation Filter Testing Program - MF7352 By letter dated February 12, 2016 (Agencywide Document Access and Management System (ADAMS) Accession Numbers ML16043A217), NextEra Energy Point Beach, LLC (NextEra), the licensee for Point Beach Nuclear Plant (PBNP),
Units 1 and 2, requested to revise the PBNP facility operating licenses and the Technical Specifications (TS). The proposed revisions would remove license conditions that have been completed and are no longer in effect and revise a charcoal testing criterion for the control room emergency filtration system. In order for our staff to complete the evaluation, following additional information is requested. Please arrange a teleconference with the NRC staff, if any further clarification is needed. If not, please provide your response on the docket within 30 days of the receipt of this email. Thanks SRXB - RAI 1 The licensee states in its application that the EOPs were revised with instructions to maintain containment spray for two hours while on sump recirculation. With this EOP revision, the licensee proposes to remove the license condition from Amendment 240/Amendment 244, Emergency Operating Procedures, which states:
NextEra Energy Point Beach, LLC shall revise PBNP Emergency Operating Procedures (EOPs) to direct continued containment spray while on sump recirculation.
The NRC staff requests that the licensee confirm that the EOPs were revised to include instructions to maintain containment spray for two hours while on sump recirculation.
Mahesh Chawla Project Manager Phone: 301-415-8371 Fax: 301-415-1222 mahesh.chawla@nrc.gov
Hearing Identifier:
NRR_PMDA Email Number:
2911 Mail Envelope Properties (Mahesh.Chawla@nrc.gov20160617163700)
Subject:
Request for Additional Information - Point Beach, Units 1 & 2 - License Amendment Request - Removal of Completed License Conditions and Change to the Ventilation Filter Testing Program - MF7352 Sent Date:
6/17/2016 4:37:46 PM Received Date:
6/17/2016 4:37:00 PM From:
Chawla, Mahesh Created By:
Mahesh.Chawla@nrc.gov Recipients:
"Wrona, David" <David.Wrona@nrc.gov>
Tracking Status: None "Hardgrove, Matthew" <Matthew.Hardgrove@nrc.gov>
Tracking Status: None "Oesterle, Eric" <Eric.Oesterle@nrc.gov>
Tracking Status: None "Nold, David" <David.Nold@nrc.gov>
Tracking Status: None "West, Khadijah" <Khadijah.West@nrc.gov>
Tracking Status: None "Parillo, John" <John.Parillo@nrc.gov>
Tracking Status: None "Sweat, Tarico" <Tarico.Sweat@nrc.gov>
Tracking Status: None "Edmonds, Shavon" <Shavon.Edmonds@nrc.gov>
Tracking Status: None "Woyak, Bryan (Bryan.Woyak@nexteraenergy.com)" <Bryan.Woyak@nexteraenergy.com>
Tracking Status: None "Locke, Kim (Kim.Locke@nexteraenergy.com)" <Kim.Locke@nexteraenergy.com>
Tracking Status: None "michael.millen@nexteraenergy.com" <michael.millen@nexteraenergy.com>
Tracking Status: None Post Office:
Files Size Date & Time MESSAGE 1596 6/17/2016 4:37:00 PM Options Priority:
Standard Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
Recipients Received: