LIST OF TABLES Table No.

Page 2.3-1 Reactor Protective System Trip Setting Limits Units 1,2 and 3 2.3-5 3.5.1-1 Instruments Operating Conditions 3.5-4 3.5-1 (Not Used) 3.5-14 3.5.5-1 (Not Used) 3.5-39 3.5.5-2 (Not Used) 3.5-41 3.5.6-1 Accident Monitoring Instrumentation 3.5-45 3.7-1 Operability Requirements for the Emergency Power 3.7-14 Switching Logic Circuits 3.17-1 (Not Used) 3.18-1 SSF Minimum Instrumentation 3.18-6 4.1-1 Instrument Surveillance Requirements 4.1-3 4.1-2

-Minimum Equipment Test Frequency 4.1-9 4.1-3 Minimum Sampling Frequency and Analysis Program 4.1-10 4.1-4 (Not Used) 4.1-16 4.4-1 List of Penetrations with 10CFR5O Appendix J Test Requirements 4.4-6 4.11-1 (Not Used) 4.11-3 4.11-2 (Not Used) 4.11-5 4.11-3 (Not Used) 4.11-8 4.17-1 Steam Generator Tube Inspection 4.17-6 4.20-1 SSF Instrumentation Surveillance Requirements 4.20-5 6.1-1 Minimum Operating Shift Requirements with Fuel in Three Reactor Vessels 6.1-6 9206150423 920605 PDR ADOCK 05000269

\\.P PDR Amendment No. 195 (Unit 1)

OCONEE 1, 2, and 3 vi Amendment No. 195 (Unit 2)

Amendment No. 192 (Unit 3)

ADDITIONAL REQUIREMENTS

1. One licensed operator per unit shall be in the Control Room at all times when there is fuel in the reactor vessel.
2. Two licensed operators shall be in the Control Room during startup and scheduled shutdown of a reactor.
3. At least one licensed operator shall in the reactor building when fuel handling operations in the reactor building are in progress.
4. An operator holding a Senior Reactor Operator license and assigned no other operational duties shall be in direct charge of refueling operations.
5. At least one person per shift shall have sufficient training to perform routine health physics requirements.
6. If the computer for a reactor is inoperable for more than eight hours, an operator, in additional to those required in (1) and (2) above, shall supplement the Control Room shift crew.
7. An operator holding a Senior Reactor Operator's license shall be in the Control Room from which the unit is operated whenever the unit is above cold shutdown.
8. Temporary deviations from the requirements of Table 6.6-1 may be allowed in cases of sudden illness, injury or other similar emergencies provided replacement personnel are notified immediately and are on site as soon as possible to return shift manning to minimum.
9. The qualified manpower necessary for achieving alternate shutdown using the SSF will be available at the plant at all times. The manpower necessary to operate the SSF will be exclusive of the fire brigade and the 3 member minimum operating shift that is required to be present in the Control Room.

Amendment No. 195 (Unit 1)

OCONEE 1, 2, and 3 6.1-6a Amendment No. 195 (Unit 2)

Amendment No. 192 (Unit 3)