ML16137A728
| ML16137A728 | |
| Person / Time | |
|---|---|
| Site: | Oconee, McGuire |
| Issue date: | 05/05/1980 |
| From: | James O'Reilly NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| To: | Parker W DUKE POWER CO. |
| References | |
| NUDOCS 8005280226 | |
| Download: ML16137A728 (4) | |
Text
Q REQ04 UNITED STATES NUCLEAR REGULATORY COMMISSION REGION II 101 MARIETTA ST., N.W., SUITE 3100 ATLANTA, GEORGIA 30303 In Reply Refer To:
MAY 5 1980 RII:JPO 5 26 9 rD UF ULATORY DOC COPY 50-270 Duke Power Company Attn: W. 0. Parker, Jr.
Vice President, Steam Production P. 0. Box 2178 Charlotte, NC 28242 Gentlemen:
This Information Notice is provided as an early notification of a possibly significant matter. It is expected that recipients will review the information for possible applicability to their facilities. No specific action or response is requested at this time. If further NRC evaluations so indicate, an IE Circular or Bulletin will be issued to recommend or request specific licensee actions. If you have any questions regarding this matter, please contact the Director of the appropriate NRC Regional Office.
Sincerely, James P. O'Reilly Director
Enclosures:
- 1.
IE Information Notice No. 80-18
- 2.
List of Recently Issued IE Information Notices 022
AY 1980 Duke Power Company
-2 cc w/encl:
M. D. McIntosh, Project Manager Post Office Box 488 Cornelius, North Carolina 28031 J. C. Rogers, Project Manager Post Office Box 33189 Charlotte, North Carolina 28242 J. E. Smith, Station Manager Post Office Box 1175 Seneca, South Carolina 29678
UNITED STATES SSINS No. 6870 NUCLEAR REGULATORY COMMISSION Accessions No.:
OFFICE OF INSPECTION AND ENFORCEMENT 8002280673 WASHINGTON, D.C. 20555 May 5, 1980 IE Information Notice No. 80-18 POSSIBLE WEAPONS SMUGGLING POUCH The NRC recently received information concerning a device used for smuggling that can preclude detection of weapons by security X-ray machines. The device is described as a gray, metalfoil pouch measuring approximately 20" x 12" which can be folded to wallet size when not in use. When in use, X-ray images produce only a mottled picture with no indications of a solid mass such as that of a weapon or similar contraband.
The same material used to construct the pouch has been used to line hollow compartments of hand-carried packages and parcels such as attache and cosmetic cases.
The pouch is reported to look something like a leadlined pouch sold in the U.S.
to protect film from harmful X-ray effect, except that the U.S. manufactured pouch distinctly reveals the silhouette of any solid mass content such as that produced by a gun when subjected to X-ray.
This Information Notice is provided as an early notification of a possible significant matter that is still under review by the NRC staff. It is expected that recipients will review the information for possible applicability to their facility. No specific action or response is requested at this time.
If you have any questions regarding this matter, please contact the Director of the appropriate NRC Regional Qffice.
IE Information Notice No. 80-18 Enclosure May 5, 1980 RECENTLY ISSUED IE INFORMATION NOTICES Information Subject Date Issued To Notice No.
Issued 80-18 Possible Weapons Smuggling 5/5/80 All PWRs with an OL, Pouch fuel fabrication &
processing facilities and Materials Priority I Licensees 80-17 Potential Hazards Associated 5/5/80 All radiography With Interchangable Parts Licenses On Radiographic Equipment 80-16 Shaft Seal Packing 4/29/80 All power reactor Causes Binding In Main facilities in your Steam Swing Check And Region with an OL or CP Isolation Valves 80-15 Axial (Longitudinal) 4/21/80 All Light Water Reactor Oriented Cracking In Facilities holding power Piping reactor OLs or CPs 80-14 Safety Suggestions From 412/80 All power reactor Employees facilities with an OL or CP 80-13 General Electric Type SBM 4/2/80 All light water reactor Control Switches - Defective "facilities holding power Cam Followers reactor OLs or CPs 80-12 Instrument Failure Causes 3/31/80 All holders of power Opening of PORV and Block reactor OLs and CPs Valve 80-11 General Problems with ASCO 3/14/80 All holders of Reactor Valves in Nuclear Application OL, CP, fuel fabrica Including Fire Protection tion and processing Systems facilities 80-10 Partial Loss of Non-Nuclear 3/7/80 All power reactor Instrument System Power facilities holding Supply During Operation.
OLs and CPs 80-09 Possible Occupational 3/7/80 All holders of Health Hazard Associated power reactor OLs with Closed Cooling Systems and near term CPs 80-08 The States Company Sliding 3/7/80 All power reactor Link Electrical Terminal facilities with an OL Block or a CP