UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 X

December 3, 1992 Docket Nos. 50-269, 50-270 and 50-287 Mr. J. W. Hampton Vice President, Oconee Site Duke Power Company P. 0. Box 1439 Seneca, South Carolina 29679

Dear Mr. Hampton:

SUBJECT:

SUPPLEMENTAL SAFETY EVALUATION FOR STATION BLACKOUT (10 CFR 50.63) - OCONEE NUCLEAR STATION, UNITS 1, 2, AND 3 (TACS M68574/M68575/M68576)

The NRC staff's Safety Evaluation (SE) pertaining to Duke Power Company's response to the Station Blackout (SBO) rule, 10 CFR 50.63, was transmitted to you by letter dated March 10, 1992. The staff's SE found that your proposed method of coping with an SBO at the Oconee Nuclear Station did not conform with the SBO rule, and requested the submittal of a revised response addressing the areas of non-conformance.

You responded to our request by meeting with the NRC staff on June 4, 1992, and submitting a written response dated July 1, 1992. We have completed our review of your revised response and find it to be acceptable as discussed in the enclosed supplemental SE (SSE). However, you should ensure that the control room heat-up calculations do not result in non-conservative results for control room temperatures (Section 2.4 of the SSE).

You stated that the actions required to perform load stripping, the implementation of administrative controls for room temperatures, and the implementation of the evaluation of the Standby Shutdown Facility (SSF) and Keowee reliability/availability programs will be completed by January 1, 1993.

If you do not intend to implement these actions on this schedule, you should submit a response within 30 days of receipt of this SE in accordance with 10 CFR 50.63(c)(4).

090021 9212110148 921203 PDR ADOCK 05000269 P

PDR

Mr. J. W. Hampton 2 -

December 3, 1992 This completes our review under TAC Nos. M68574, M68575, and M68576. If you have questions regarding this matter, contact me at (301) 504-1495.

Sincerely,

/s/

Leonard A. Wiens, Project Manager Project Directorate 11-3 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Enclosure:

Safety Evaluation cc w/enclosure:

See next page DISTRIBUTION:

"Docket File NRC & Local PDRs PDII-3 R/f Oconee R/F SVarga GLainas DMatthews LWiens LBerry OGC, 15B18 ACRS (10), P-315 EMerschoff, RH

PTam, 14B21 CBerlinger, 8D22 AToalston 7E4 PDII-3:

I PM D

II-3 L~erry LWiens:cw D atthews

/ /92 j

5/92

/

2 OFFICIAL RECORD COPY

/

DOCUMENT NAME:

G:\\OCONEE\\ONSSBO

Mr. J. December 3, 1992 This completes our review under TAC Nos. M68574, M68575, and M68576. If you have questions regarding this matter, contact me at (301) 504-1495.

Sincerely, conard A. Wiens, Project Manager Project Directorate 11-3 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Enclosure:

Safety Evaluation cc w/enclosure:

See next page

0 0

Mr. J. W. Hampton Duke Power Company Oconee Nuclear Station cc:

Mr. A. V. Carr, Esquire Mr. M. E. Patrick Duke Power Company Compliance 422 South Church Street Duke Power Company Charlotte, North Carolina 28242-0001 Oconee Nuclear Site P. 0. Box 1439 J. Michael McGarry, III, Esquire Seneca, South Carolina 29679 Winston and Strawn 1400 L Street, NW.

Mr. Alan R. Herdt, Chief Washington, DC 20005 Project Branch #3 U. S. Nuclear Regulatory Commission Mr. Robert B. Borsum 101 Marietta Street, NW. Suite 2900 Babcock & Wilcox Atlanta, Georgia 30323 Nuclear Power Division Suite 525 Ms. Karen E. Long 1700 Rockville Pike Assistant Attorney General Rockville, Maryland 20852 North Carolina Department of Justice Manager, LIS P. 0. Box 629 NUS Corporation Raleigh, North Carolina 27602 2650 McCormick Drive, 3rd Floor Clearwater, Florida 34619-1035 Mr. R. L. Gill, Jr.

Licensing Senior Resident Inspector Duke Power Company U. S. Nuclear Regulatory Commission P. 0. Box 1006 Route 2, Box 610 Charlotte, North Carolina 28201-1006 Seneca, South Carolina 29678 Regional Administrator, Region II U. S. Nuclear Regulatory Commission 101 Marietta Street, NW. Suite 2900 Atlanta, Georgia 30323 Mr. Heyward G. Shealy, Chief Bureau of Radiological Health South Carolina Department of Health and Environmental Control 2600 Bull Street Columbia, South Carolina 29201 Office of Intergovernmental Relations 116 West Jones Street Raleigh, North Carolina 27603 County Supervisor of Oconee County Walhalla, South Carolina 29621