Exelon Generation May 6, 2016 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington DC 20555-0001 Peach Bottom Atomic Power Station, Units 2 and 3 Renewed Facility Operating License Nos. DPR-44 and DPR-56 NRC Docket Nos. 50-277 and 50-278 TS 5.6.5.d

Subject:

Issuance of the Core Operating Limits Reports for Implementation of the Maximum Extended Load Line Limit Analysis Plus Analysis Enclosed are copies of Revision 10 and Revision 9 of the Core Operating Limits Reports (COLRs) for Peach Bottom Atomic Power Station (PBAPS) Units 2 and 3, respectively. These revisions incorporate the implementation of the Maximum Extended Load Line Limit Analysis Plus license amendments 305/307.

The COLR revisions are being submitted to the NRC as required by the PBAPS, Units 2 and 3 Technical Specifications (TS) Section 5.6.5.d.

If you have any questions concerning this letter, please contact Dave Foss at (717) 456-4311.

Site Vice President Peach Bottom Atomic Power Station CCN: 16-41 Attachments Unit 2 Core Operating Limits Report for Reload 20, Cycle 21, Revision 10 Unit 3 Core Operating Limits Report for Reload 20, Cycle 21, Revision 9 cc:

Regional Administrator, Region I, USNRC (without attachments)

USNRC Senior Resident Inspector, PBAPS (without attachments)

Project Manager-PBAPS, USNRC (with attachments)

R. R. Janati, Pennsylvania Bureau of Radiation Protection (without attachments)

S. T. Gray, State of Maryland (without attachments)

ATTACHMENT Unit 2 Core Operating Limits Report for Reload 20, Cycle 21, Revision 10

Exeloa Nuclear* Nuclear Fuelll P2C2 l Core Operating Limits Report COLR PEACH BOTIOM 2 Rev. 10 Page 1 of23 CORE OPERATING Lll\\flTS REPORT FOR PEACH BOTTOM ATOl\\flC POWER STATION UNIT 2 Prepared By:

Co-Prepared By:

Reviewed By:

Reviewed By:

Independent Review By:

Approved By:

Station Qualified Reviewer:

RELOAD 20, CYCLE 21 (fhis is a Complete Re-write)

T.Bement Q~

~:s.

P.Hemy Engineering SafetY Analysis

~

C.Burns

~

.:ef "4M/ -~

~

J.J.Tusar Date: 1/29/16 Date: 1 /29/16 Date: 02/03/16 Date: 2/3/16 Date: 2/3/2016 Date:

2/3/16 Date: 2.. / Z. 2 j, (o

Exelon Nuclear - Nuclear Fuels P2C21 Core Operating Limits Report COLR PEACH BOTTOM 2 Rev. 10 Page 2of23 Table of Contents Page 1.0 Terms and Definitions 4

2.0 General Information 5

3.0 MAPLHGR Limits 6

4.0 MCPRLimits 7

5.0 Linear Heat Generation Rate Limits 10 6.0 Rod Block Monitor Setpoints 12 7.0 Turbine Bypass Valve Parameters 13 8.0 EOC Recirculation Pump Trip (EOC-RPI) Operability 14 9.0 Stability Protection 15 10.0 Asymmetric Feedwater Temperature Operation (AFTO) 17 11.0 Modes of Operation 21 12.0 Methodology 21 13.0 References 22 Appendix A (Power/Flow Operating Map for MELLLA+)

23

Exelon Nuclear

  • Nuclear Fuels P2C21 Core Operating Limits Report COLR PEACH BOTIOM 2 Rev. 10 Page 3 of 23 List of Tables Table 3-1 MAPLHGR Versus Average Planar Exposure Table 3-2 MAPLHGR Single Loop Operation (SLO) Multiplier Table 4-1 Operating Limit Minimum Critical Power Ratio Table 4-2 Power Dependent MCPR(P) Limit Adjustments and Multipliers Table 4-3 Flow Dependent MCPR Limits MCPR(F)

Table 4-4 SLO Flow Dependent MCPR Limits MCPR(F)

Page 6

6 8

9 9

9 Table 5-1 Linear Heat Generation Rate Limits - U02 rods 10 Table 5-2 Linear Heat Generation Rate Limits - Gad rods 10 Table 5-3 Power Dependent LHGR Multiplier LHGRFAC(P) 11 Table 5-4 Flow Dependent LHGR Multiplier LHGRFAC(F) 11 Table 6-1 Rod Block Monitor Setpoints 12 Table 7-1 Turbine Bypass System Response Time 13 Table 7-2 Minimum Required Bypass Valves to Maintain System Operability 13 Table 8-1 Recirculation Pump Trip Response Time 14 Table 9-1 Automatic BSP Setpoints for the Scram Region 15 Table 9-2 Manual BSP Endpoints for Normal Feedwater Temperature 16 Table 9-3 Manual BSP Endpoints for Reduced Feedwater Temperature 16 Table 10-1 AFTO Thermal Limit Penalties 17 Table 10-2 AFTO Power Dependent LHGR Multiplier LHGRFAC(P) 20F < FWT DELTA~ 55F 18 Table 10-3 AFTO Flow Dependent LHGR Multiplier LHGRFAC(F) 20F < FWT DELTA~ 55F 18 Table 10-4 AFTO Operating Limit Minimum Critical Power Ratio 20F < FWT DELTA~ 55F 19 Table 10-5 AFTO Power Dependent MCPR Limit Adjustments and Multipliers MCPR(P) 20F<FWTDELTA~55F 19 Table 10-6 AFTO Flow Dependent MCPR Limits MCPR(F) 20F < FWT DELTA~ 55F 20 Table 10-7 AFTO MAPLHGR Reduction Factor 20 Table 11-1 Modes of Operation 21 Table 11-2 Additional Equipment Out Of Service Modes of Operation 21

Exelon Nuclear - Nuclear Fuels P2C21 Core Operating Limits Report COLR PEACH BOTIOM 2 Rev. 10 Page4of23 1.0 Terms and Definitions ABSP AFfO AFfOLFWH APRM ARTS BASE BOC DSS-CD DTSP EOC EOOS EOR FFWIR FWHOOS FWT HFCL HTSP ICF ITSP LHGR LHGRFAC(F)

LHGRFAC(P)

LTSP MAPLHGR MCPR MCPR(F)

MCPR(P)

MELLLA MELLLA+

MSIVOOS NCL OLM CPR PLUOOS PROOS RDF RPTOOS RTP RWE SLM CPR SLO TBVOOS TCVffSVOOS Automatic Backup Stability Protection Asymmetric Feedwater Temperature Operation Asymmetric Feedwater Temperature Operation Loss-of-Feedwater Heating Average Power Range Monitor APRM and RBM Technical Specification Analysis Defines two (2) loop operation with at least seven turbine bypass valves in service and the reactor recirculation pump trip system in service.

Beginning Of Cycle Detect and Suppress Solution - Confirmation Density Rod Block Monitor Downscale Trip Setpoint End of Cycle Equipment Out of Service. An analyzed option that assumes certain equipment to be non-operational End of Rated. The cycle exposure at which reactor power is equal to 100% (3951 MWth) with recirculation system flow equal to 100%, all control rods fully withdrawn, all feedwater heating in service and equilibrium Xenon.

Final Feedwater Temperature Reduction Feedwater Heaters Out of Service Feedwater Temperature High How Control Line Rod Block Monitor High Trip Setpoint Increased Core How Rod Block Monitor Intermediate Trip Setpoint Linear Heat Generation Rate ARTS LHGR thermal limit flow dependent adjustments and multipliers ARTS LHGR thermal limit power dependent adjustments and multipliers Rod Block Monitor Low Trip Setpoint Maximum Average Planar Linear Heat Generation Rate Minimum Critical Power Ratio ARTS MCPR thermal limit flow dependent adjustments and multipliers ARTS MCPR thermal limit power dependent adjustments and multipliers Maximum Extended Load Line Limit Analysis Maximum Extended Load Line Limit Analysis Plus Main Steam Isolation Valve Out of Service Natural Circulation Line Operating Limit Minimum Critical Power Ratio Power Load Unbalance Out of Service Pressure Regulator Out of Service Rated Drive How Recirculation Pump Trip Out of Service Rated Thennal Power Rod Withdrawal Error Safety Limit Minimum Critical Power Ratio Single Loop Operation Turbine Bypass Valves Out of Service Turbine Control V alvetrurbine Stop Valve Out of Service

Exelon Nuclear

  • Nuclear Fuels P2C21 Core Operating Limits Report 2.0 General Information COLR PEACH BOTTOM 2 Rev. 10 Page 5 of.23 This report provides the following cycle-specific p~eter limits for Peach Bottom Atomic Power Station Unit 2 CYCLE 21 (RELOAD 20):

Maximum Average Planar Linear Heat Generation Rate (MAPLHGR)

Single Loop Operation (SLO) MAPLHGR multipliers Operating Limit Minimum Critical Power Ratio (OLMCPR)

ARTS MCPR thermal limit adjustments and multipliers Single Loop Operation (SLO) MCPR adjustment Linear Heat Generation Rate (LHGR)

ARTS LHGR thermal limit multipliers Single Loop Operation (SLO) LHGR multipliers Rod Block Monitor (RBM) Analytical Limits, Allowable Values and MCPR Limits Turbine Bypass Valve Parameters BOC Recirculation Pump Trip (EOC-RPT) Parameters Stability Protection Setpoints Asymmetric Feedwater Temperature Operation (AFTO) thennal limit penalties These values have been determined using NRC-approved methodology and are established such that all applicable limits of the plant safety analysis are met. SLO, FWHOOS operation, and FFWTR operation are not permitted in the MELLLA+ Region as controlled by station procedures. For the MELLLA+ Region, a specific definition of FWHOOS is provided in Facility Operating License (FOL) Section 2.C(l6).

This report provides cycle-specific Operating Limit MCPR, LHGR, MAPLHGR thermal limits, and related information for the following conditions:

All points in the operating region of the power/flow map including the MELLLA+ Region down to 83%

of rated core flow during full power (3951 MWt) operation (Appendix A)

Increased Core Flow (ICF), up to 110% of rated core flow End-of-Cycle Power Coastdown to a minimum power level of 40%

Feedwater Heaters Out of Service (FWHOOS) to 55° F temperature reduction Final Feedwater Temperature Reduction (FFWTR) between End-of-Rated (EOR) and End-of-Cycle (EOC) to 90° F temperature reduction (4th and 5th stage FFWTR)

Asymmetric Feedwater Temperature Operation (AFTO)

ARTS provides for power-and flow-dependent thermal limit adjustments and multipliers that allow for a more reliable administration of the MCPR and LHGR thermal limits. The OLMCPR is determined by the cycle-specific reload analyses in Reference 2. Rated LHGR values are obtained from the bundle-specific thermal-mechanical analysis. Supporting documentation for the ARTS-based limits is provided in Reference 2. The Allowable Values documented in Reference 5 for feedwater temperature as a function of thermal power for both FWHOOS and FFWTR are specified in the appropriate Peach Bottom procedures.

Also note that the following description of MAPLHGR, LHGR and MCPR limits pertain to NON - AFTO conditions. A separate description of AFTO limits and their associated ARTS tables are located in Section 10.

Preparation of this report was performed in accordance with Exelon Nuclear procedures. This report is provided to the NRC in accordance with Technical Specification 5.6.5 of Reference 1 and contains all thermal limit parameters related to the implementation of the ARTS hnprovement Program and MELLLA+ for Peach Bottom Unit 2 Cycle 21.

The "BASE" thermal limit values shown in tables are for normal two loop operation with at least the minimum number of turbine bypass valves in service per Section 7.0 and the reactor recirculation pump trip system in service.

Exelon Nuclear* Nuclear Fuels P2C21 Core Operating Limits Report 3.0 MAPLHGR LIMITS 3.1 Technical Specification Section 3.2.1, 3.3.4.2, 3.4.1 and 3.7.6 3.2 Description COLR PEACH BOTTOM 2 Rev. 10 Page 6of23 The MAPLHGR limits (kW/ft) obtained from the emergency core cooling system (ECCS) analysis are provided in Table 3-1. The MAPLHGR limits comprise a given fuel type as a function of average planar exposure. The MAPLHGR tables are used when hand calculations are required. All MAPLHGR values for GNF2 as a function of axial location and average planar exposure shall be less than or equal to the applicable MAPLHGR limits for GNF2 fuel and lattice type. These MAPLHGR limits are specified in Reference 2 and the process computer databank. The SLO MAPLHGR multiplier is provided in Table 3-2 per Reference 2 and must be applied to the Table 3-1 limits when operating in SLO. The impact of AFfO on MAPLHGR is addressed in Section 10.

TABLE3-1 MAPLHGR Versus Average Planar Exposure (Reference 2)

Average Planar Exposure MAPLHGR Limit (GWD/ST)

(kW/ft) 0.0 13.78 17.52 13.78 60.78 7.50 63.50 6.69 TABLE3-2 MAPLHGR Single Loop Operation (SLO) Multiplier (Reference 2)

SLO Multiplier 0.73

Exelon Nuclear

  • Nuclear Fuels P2C21 Core Operating Umits Report 4.0 MCPR LIMITS 4.1 Technical Specification Section 2.1.1.2, 3.2.2, 3.3.4.2, 3.4.1and3.7.6 4.2 Description COLR PEACH BOTTOM 2 Rev. 10 Page 7 of 23 The Operating Limit MCPR (OLMCPR) for GNF2 fuel is provided in Tables 4-1 and 4-2. These values are detennined by the cycle-specific fuel reload analyses in Reference 2. Control rod scram time verification is required as per Technical Specification 3.1.4, "Control Rod Scram Times". Tau, a measure of scram time performance to notch position 36 throughout the cycle, is detennined based on the cumulative scram time test results. The calculation of Tau shall be performed in accordance with site procedures. Linear interpolation shall be used to calculate the OLMCPR value if Tau is between 0.0 (Tau Option B) and 1.0 (Tau Option A).

Separate OLMCPR values are presented in Table 4-1 for the following conditions:

  • TBVs In-Service (per section 7.0), RPT In-Service (per section 8.0), and maximum FFWTR of 90 °P (a.k.a. "BASE")
  • TBVs Out-of-Service (per section 7.0), RPT In-Service (per section 8.0), and maximumFFWTR of90 °P
  • TBV s In-Service (per section 7.0), RPT Out-of-Service (per section 8.0), and maximum FFWTR of 90 °P The ARTS-based power-dependent MCPR limits are provided in Table 4-2. Table 4-2 is valid for a maximum temperature reduction of 90 °P for FFWTR operation (bounding for FWHOOS operation). The flow-dependent MCPR limits are provided in Tables 4-3 and 4-4. Table 4-3 is valid for dual loop operating conditions with symmetric feedwater temperature operation and Table 4-4 is valid for single loop operating conditions with symmetric feedwater temperature operation. The impact of AFTO on MCPR is addressed in Section 10.

Exelon Nuclear *Nuclear Fuels P2C21 Core Operating Limits Report TABLE4*1 COLR PEACH BOTIOM 2 Rev. 10 Page 8of23 Operating Limit Minimum Critical Power Ratio (Reference 2)

SCRAM Cycle EXPosure Time

<EOR-4409

~EOR-4409 EOOS Combination Option<l)

MWd/ST MWd/ST B

1.40 1.40 BASE A

1.41 1.48 B

1.43 1.43 BASESLO A

1.43 1.48 B

1.44 1.44 TBVOOS A

1.44 1.52 B

1.44 1.44 TBVOOSSLO A

1.44 1.52 B

1.40 1.47 RPTOOS A

1.56 1.64 B

1.43 1.47 RPTOOSSLO A

1.56 1.64 (1) When Tau does not equal O or 1, use linear interpolation

Exelon Nuclear

  • Nuclear Fuels P2C21 Core Operating Limits Report TABLE4-2 COLR PEACH BOTTOM 2 Rev. 10 Page 9of23 Power Dependent MCPR(P) Limit Adjustments And Multipliers (Symmetric Feedwater Heating)

(Reference 2)

Core Core Thermal Power ( % of rated)

EOOS Combination Flow(%

0 23

<.26.7

~6.7 40 55 65 85 100 of rated) Operating Limit MCPR Operating Limit MCPR Multiplier, Kp Base Base SLO RPTOOS RPTOOSSLO TBVOOS TBVOOSSLO s6o

>60 s6o

>60 s6o

>60 s6o

>60 s6o

>60 s6o

>60 2.67 2.67 2.60 1.352 1.352 2.99 2.99 2.83 2.67 2.67 2.60 1.352 1.352 2.99 2.99 2.83 2.67 2.67 2.60 1.352 2.99 2.99 2.83 1.352 2.67 2.67 2.60 1.352 1.352 2.99 2.99 2.83 3.64 3.64 3.25 4.15 4.15 3.78 1.659 1.479 3.64 3.64 3.25 1.659 1.479 4.15 4.15 3.78 TABLE4-3 Flow Dependent MCPR Limits MCPR(F)

(Symmetric Feedwater Heating)

(Reference 2)

Core Flow MCPR(F)

(%rated)

Limit 0.0 1.75 30.0 1.57 79.0 1.28 110.0 1.28 TABLE4-4 1.317 1.317 1.317 1.317 1.373 1.373 SLO Flow Dependent MCPR Limits MCPR(F)

(Symmetric Feedwater Heating)

(Reference 2)

Core Flow MCPR(F)

(%rated)

Limit 0.0 1.75 30.0 1.57 79.0 1.28 110.0 1.28 1.131 1.082 1.000 1.131 1.082 1.000 1.131 1.082 1.000 1.131 1.082 1.000 1.155 1.082 1.000 1.155 1.082 1.000

Exelon Nuclear

  • Nuclear Fuels P2C21 Core Operating Limits Report COLR PEACH BOTTOM 2 Rev. 10 Page 10of23 5.0 LINEAR HEAT GENERATION RATE LIMITS 5.1 Technical Specification Section 3.2.3, 3.3.4.2, 3.4.1and3.7.6 5.2 Description The LHGR values for GNF2 fuel type are provided in Tables 5-1 and 5-2. The ARTS-based LHGR power-dependent multipliers are provided in Table 5-3. Table 5-3 is valid for a maximum temperature reduction of 90° F for FFWTR operation (bounding for FWHOOS operation). The flow-dependent multipliers are provided in Table 5-4 as a function of the number of recirculation loops in operation.

The SLO LHGR multiplier is provided and accounted for in Table 5-4. The power-and flow-dependent LHGR multipliers were obtained from Reference 2. The impact of AFTO on LHGR is addressed in Section 10. The power and flow dependent LHGR multipliers are sufficient to provide adequate protection for the off-rated conditions from an ECCS-LOCA analysis perspective.

TABLES-1 Linear Heat Generation Rate Limits - U02 rods (References 4 and 11)

Fuel Type LHGRLimit GNF2 See Appendix B of Reference 4 TABLES-2 Linear Heat Generation Rate Limits - Gad rods (References 4 and 11)

Fuel Type LHGRLimit GNF2 See Appendix B of Reference 4

Exelon Nuclear - Nuclear Fuels P2C21 Core Operating Limits Report TABLE5-3 COLR PEACH BOTTOM 2 Rev. 10 Page 11of23 Power Dependent LHGR Multiplier LHGRFAC(P)

(Symmetric Feedwater Heating)

(Reference 2)

Core Flow Core Thermal Power ( % of rated)

EOOS Combination Base Base SLO RPTOOS RPTOOSSLO TBVOOS TBVOOSSLO EOOS Combination Dual Loop Single Loop

(%of 0

23

<26.7

~6.7 40 55 rated)

LHGRF AC(P) Multiplier

$60 0.508 0.508 0.522 0.748 0.756

>60 0.508 0.508 0.522

$60 0.508 0.508 0.522 0.508 0.748 0.756

>60 0.508 0.522

$60 0.508 0.508 0.522

>60 0.508 0.508 0.522 0.748 0.756

$60 0.508 0.508 0.522 0.748 0.756

>60 0.508 0.522 0.508

$60 0.397 0.397 0.442 0.635 0.655

>60 0.410 0.410 0.417

$60 0.397 0.397 0.442 0.635 0.655

>60 0.410 0.410 0.417 TABLE5-4 Flow Dependent LHGR Multiplier LHGRFAC(F)

(Symmetric Feedwater Heating)

(Reference 2)

Core Flow ( % of rated) 0 30 33.6 70 LHGRF AC(F) Multiplier 0.506 0.706 0.730 0.973 0.506 0.706 0.730 0.730 0.771 0.771 0.771 0.771 0.714 0.714 80 1.000 0.730 65 85 0.817 0.959 0.817 0.959 0.817 0.959 0.817 0.959 0.817 0.930 0.817 0.930 110 1.000 0.730 100 1.000 1.000 1.000 1.000 1.000 1.000

Exelon Nuclear

  • Nuclear Fuels P2C21 Core Operating Limits Report COLR PEACH BOTTOM 2 Rev. 10 Page 12of23 6.0 ROD BLOCK MONITOR SETPOINTS 6.1 Technical Specification Section 3.3.2.1 6.2 Description The RBM power-biased Analytical Limits, Allowable Values and MCPR Limits are provided in Table 6-1 with supporting documentation in References 2 and 9. These values correspond to the OLMCPR values provide in Table 4-1.

Power Level LTSP ITSP HTSP INOP TABLE 6-1 Rod Block Monitor Setpoints (References 2 and 9)

Analytical Lintit<1>

Allowable Value0>

123.0%

121.2%

118.0%

116.2%

113.2%

111.4%

NIA NIA MCPRLimit

< 1.70 <2>

< 1.40 <3>

< 1.70 <2>

< 1.40 <3>

< 1.70 <2>

< 1.40 <3>

< 1.70 <2>

< 1.40 <3>

(1) These setpoints (with RBM filter time constant between 0.1 seconds and 0.55 seconds) are based on a cycle-specific rated RWE MCPR limit which is less than or equal to the minimum cycle OLMCPR based on other events (see COLR References 2 and 9).

(2) This is the MCPR limit (given THERMAL POWER is >28.4% and < 90%) below which the RBM is required to be OPERABLE (see COLR Reference 2 and TS Table 3.3.2.1-1).

(3) This is the MCPR limit (given THERMAL POWER is > 90%) below which the RBM is required to be OPERABLE (see COLR Reference 2 and TS Table 3.3.2.1-1). -

Exelon Nuclear - Nuclear Fuels P2C21 Core Operating Limits Report COLR PEACH BOTTOM 2 Rev. 10 Page 13of23 7.0 TURBINE BYPASS VAL VE PARAMETERS 7.1 Technical Specification Section 3.7.6 7.2 Description The operability requirements for the steam bypass system are governed by Technical Specification 3.7.6.

If the requirements cannot be met, the appropriate power and flow dependent limits for Turbine Bypass Valves Out-of-Service (TBVOOS) must be used. Additionally, the OLMCPR for TBVOOS must be applied. Table 7-1 includes the Turbine Bypass Valve response time parameters. The minimum number of bypass valves to maintain system operability is provided in Table 7-2 per Refer~nce 14.

TABLE7-1 Turbine Bypass System Response Time (Reference 14)

Maximum delay time before start of bypass valve opening following initial turbine inlet valve movement0>

Maximum time after initial turbine inlet valve movement0> for bypass valve position to reach 80% of full flow (includes the above delay time) 0.10 sec 0.30 sec (1)

Fust movement of any TSV QI any TCV QI generation of the turbine bypass valve flow signal (whichever occurs first)

TABLE7*2 Minimum Required Bypass Valves To Maintain System Operability (Reference 14)

Reactor Power No. of Valves in Service P~23%

7

Exelon Nuclear - Nuclear Fuels P2C21 Core Operating Limits Report COLR PEACH BOTTOM 2 Rev.10 Page 14of23 8.0 EOC RECIRCULATION PUMP TRIP (EOC-RPT) OPERABILITY 8.1 Technical Specification Section 3.3.4.2 8.2 Description The operability requirements for the EOC Recirculation Pump Trip are governed by Technical Specification 3.3.4.2. If the requirements cannot be met, the appropriate power and flow dependent limits for EOC Recirculation Pump Trip Out Of Service (RPTOOS) must be used. Additionally, the OLMCPR for RPTOOS must be applied. Table 8-1 includes the total RPT response time parameter.

TABLES-1 Recirculation Pump Trip Response Time (Reference 14)

Total Recirculation Pump Trip Response Time The time from when the turbine valves (turbine control valve or turbine stop valve) start to close until complete arc suppression of the EOC-RPT circuit breakers as described in Reference 7.

0.175 sec

Exelon Nuclear - Nuclear Fuels P2C21 Core Operating Limits Report 9.0 STABILITY PROTECTION 9.1 Technical Specification COLR PEACH BOTTOM 2 Rev. 10 Page 15of23 Section 3.3.1.1, Table 3.3.1.1-1Function2.f, Section 5.6.5 9.2 Description Per Reference 2, the Cycle 21 DSS-CD SAD Setpoint was confmned to be 1.10 for DLO and SLO. The Automatic Backup Stability Protection (BSP) Setpoints are provided in Table 9-1. The Manual BSP Endpoints for Normal Feedwater Temperature and Reduced Feedwater Temperature are provided in Tables 9-2 and Table 9-3.

TABLE9-1 Automatic BSP Setpoints for the Scram Region (Reference 2)

Parameter Symbol Value Slope of ABSP APRM flow-Illrrip 1.65 biased trip linear segment.

ABSP APRM flow-biased trip setpoint power intercept.

Constant Power Line for Trip PasP-Trip 40.5 %RTP from zero Drive Flow to Flow Breakpoint value.

ABSP APRM flow-biased trip setpoint drive flow intercept.

WasP-Trip 46.7 %RDF Constant Flow Line for Trip.

Flow Breakpoint value WasP-Break 25.0 %RDF

Exelon Nuclear *Nuclear Fuels P2C21 Core Operating Limits Report COLR PEACH BOTTOM 2 Rev. 10 Page 16of23 Endpoint Al Bl A2 B2 A3 B3 Endpoint Al Bl A2 B2 TABLE 9.2°>

Manual BSP Endpoints for Normal Feedwater Temperature (Reference 2)

Power(%)

Flow(%)

Definition 77.7 53.6 Scram Region Boundary, HFCL 40.5 31.0 Scram Region Boundary, NCL 64.5 50.0 Controlled Entry Region Boundary, MEL LL A 28.1 30.l Controlled Entry Region Boundary, NCL 100 99.0 BSP Boundary Intercept, MELLLA 60.5 44.9 BSP Boundary Intercept, MELLLA Line TABLE 9.3<o Manual BSP Endpoints for Reduced Feedwater Temperature (Reference 2)

Power(%)

Flow(%)

Definition 67.1 53.4 Scram Region Boundary, MELLLA 35.1 30.7 Scram Region Boundary, NCL 69.3 56.2 Controlled Entry Region Boundary, MELLLA 28.l 30.1 Controlled Entry Region Boundary, NCL Note: The BSP Boundary for Reduced Feedwater Temperature is defined by the MELLLA line, per Reference 2.

(1) Station may elect to place additional administrative margin on the endpoints provided in Table 9-2 and Table 9-3.

Exelon Nuclear - Nuclear Fuels P2C2 l Core Operating Limits Report COLR PEACH BOTTOM 2 Rev. 10 Page 17 of 23 10.0 ASYMMETRIC FEEDWATER TEMPERATURE OPERATION (AFTO)

Asymmetric feedwater heating (resulting from removing a heater string, or individual feedwater heaters, from operation) is the result of the specific configuration of the feedwater lines at Peach Bottom. A reduction in heating in either the 'A' or the 'C' heater strings will result in a temperature mismatch between the feedwater flows entering the opposite sides of the reactor vessel. This temperature mismatch may result in errors in the thermal limit values calculated by the core monitoring system. Thermal limit values for all conditions and events are impacted by these errors excluding SLO conditions. The P2C21 COLR Rev. 9 was the first COLR to no longer require implementation of SLO AFfO penalty files. The station no longer requires SLO AFI'O files or penalties due to a 3D MONICORE upgrade required for EPU operation. Asymmetric feedwater temperature operation (AFI'O) is defined as operation in a feedwater heater/string configuration that results in a specified threshold difference as described in Reference 10.

To simplify the implementation of the AFfO limits, only the maximum AFTO penalties indicated in Table 10-1 will be implemented when the threshold asymmetry temperature (temperature above which a penalty is required) is exceeded. This will minimize the number of AFl'O thermal limit tables in the COLR and core monitoring system.

40F < FWT DELTA~ 55F 30F < FWT DELTA~ 40F 20F < FWT DELTA~ 30F OF< FWT DELTA~ 20F TABLEl0-1 AFTO Thermal Limit Penalties (Asymmetric Feedwater Heating)

(Reference 10)

MFLCPR 3%

2%

2%

No Penalty LHGR LThflTS MFLPD/MAPRAT 4%

3%

2%

No Penalty The ARTS-based LHGR power-dependent multipliers for AFTO operation are provided in Table 10-2. The flow-dependent multipliers for AFTO in DLO are provided in Table 10-3. The power-and flow-dependent LHGR multipliers were obtained from Reference 2 and were adjusted with the appropriate penalties displayed in Table 10-1 as per Reference 10. The maximum feedwater temperature difference allowed without a thermal limit penalty is 20 0F. Once the temperature difference exceeds 20 °F the maximum penalties from Table 10-1 are applied to the thermal limits. Additionally, no LHGR penalties are required for asymmetric feedwater temperature option while in SLO as previously discussed.

Exelon Nuclear

  • Nuclear Fuels P2C21 Core Operating Limits Report COLR PEACH BOTTOM 2 Rev. 10 Page 18of23 TABLE 10-2 AFTO Power Dependent LHGR Multiplier LHGRFAC(P) 20F < FWT DELTA :5 55F (Asymmetric Feedwater Heating)

(References 2 and 10)

Core Thermal Power ( % of rated)

EOOS Combination Core Flow 0

23

<26.7

~6.7 40 55 65 85

(%of rated)

LHGRFAC(P) Multiplier

560 0.488 0.488 0.501 Base 0.718 0.726 0.740 0.784 0.921

>60 0.488 0.488 0.501

560 0.488 0.488 0.501 RPTOOS 0.488 0.488 0.501 0.718 0.726 0.740 0.784 0.921

>60

560 0.381 0.381 0.424 TBVOOS 0.610 0.629 0.685 0.784 0.893

>60 0.394 0.394 0.400 TABLEl0-3 AFTO Flow Dependent LHGR Multiplier LHGRFAC(F) 20F < FWT DELTA :5 55F (Asymmetric Feedwater Heating)

(References 2 and 10)

Core Flow ( % of rated)

EOOS Combination 0

I 30 I 33.60 I 70 I

80 I

110 LHGRFAC(F) Multiplier Dual Loop 0.486 I 0.678 I 0.701 I 0.934 I 0.960 I 0.960 100 0.960 0.960 0.960

Exelon Nuclear

  • Nuclear Fuels P2C21 Core Operating Limits Report MCPRL'1TS COLR PEACH BO'ITOM 2 Rev. 10 Page 19of23 The OLMCPRs during asymmetric feedwater temperature operation with a feedwater temperature difference greater than 20 °P are provided in Table 10-4. The ARTS-based power-dependent MCPR limits for use during AFTO conditions are provided in Table 10-5. The flow-dependent MCPR limits for AFTO are provided in Table 10-6. The power and flow-dependent OLMCPR curves were obtained from Reference 2 and were adjusted with a 3% penalty for feedwater temperature difference greater than 20 °P as displayed in Table 10-1 as per Reference 10. No MCPR penalties are required for asymmetric temperature differentials less than or equal to 20 °F. Additionally, no MCPR penalties are required for asymmetric feedwater temperature option while in SLO as previously discussed.

TABLEl0-4 AFTO Operating Limit Minimum Critical Power Ratio 20F < FWT DELTA :5 55F (Asymmetric Feedwater Heating)

(References 2 and 10)

SCRAM Cycle Exuosure Time

<EOR-4409

~EOR-4409 EOOS Combination Option<l)

MWd/ST MWd/ST B

1.44 1.44 BASE A

1.45 1.52 B

1.48 1.48 TBVOOS A

1.48 1.57 B

1.44 1.51 RPTOOS A

1.61 1.69 TABLE 10-5 AFTO Power Dependent MCPR Limit Adjustments And Multipliers MCPR(P) 20F < FWT DELTA :5 55F (Asymmetric Feedwater Heating)

(References 2 and 10)

Core Core Thermal Power ( % of rated)

EOOS Combination Flow(%

0 23

<26.7

'?:.26.7 40 55 65 85 100 of rated) Operating Limit MCPR Operating Limit MCPR Multiplier, Kp 560 2.75 2.75 2.68 1.352 1.317 1.131 1.000 Base 1.352 1.082

>60 3.08 3.08 2.91 560 2.75 2.75 2.68 1.000 RPTOOS

>60 3.08 2.91 1.352 1.352 1.317 1.131 1.082 3.08 560 3.75 3.75 3.35 1.000 TBVOOS

>60 4.27 3.89 1.659 1.479 1.373 1.155 1.082 4.27 (1) When Tau does not equal O or 1, use linear interpolation.

Exelon Nuclear - Nuclear Fuels P2C21 Core Operating Llmits Report TABLE 10-6 COLR PEACH BOTTOM 2 Rev. 10 Page 20of23 AFTO Flow Dependent MCPR Limits MCPR(F) 20F < FWT DELTA:::; SSF (BOC to EOC)(Asymmetric Feedwater Heating)

(References 2 and 10)

Flow MCPR(F)

(%rated)

Limit 0.0 1.80 30.0 1.62 79.0 1.32 110.0 1.32 MAPLHGR LIMITS An appropriate penalty must be applied to MAPLHGR limits under asymmetric feedwater temperature operation (AFfO) for varying temperature differentials as displayed in Table 10-1 as per Reference 10. No MAPLHGR penalties are required for asymmetric feedwater temperature option while in SLO as previously discussed.

TABLEl0-7 AFTO MAPLHGR Reduction Factor (Asymmetric Feedwater Heating)

(References 2 and 10)

AFTO Reduction Factor 20F < FWT DELTA:::: 55F I 0.960

Exelon Nuclear

  • Nuclear Fuels P2C2 l Core Operating Limits Report 11.0 MODES OF OPERATION TABLE 11*1 Modes of Operation (Reference 2)

EOOS Options1 Base, Option A or B Base SLO, Option A or B TBVOOS, Option A or B TBVOOS SLO, Option A or B RPTOOS, Option A or B RPTOOS SLO, Option A or B TBVOOS and RPTOOS, Option A or B TBVOOS and RPTOOS SLO, Option A or B TABLE 11-2 COLR PEACH BOTI'OM 2 Rev. 10 Page 21of23 Supported Operating Reldon2 Yes Yes3 Yes Yesj Yes Yes3 No No Additional Equipment Out Of Service Modes of Operation EOOS PLUOOS (controlled via station procedures)

PROOS (controlled via station procedures)

TCVfTSVOOS (controlled via station procedures)

MSNOOS (controlled via station procedures)

AFfO LFWH (controlled via station procedures) 12.0 MEmODOLOGY The analytical methods used in determining the core operating limits have been previously reviewed and approved by the NRC, specifically those described in the following document:

1. "General Electric Standard Application for Reactor Fuel", NEDE-24011-P-A-22, November 2015 and U.S.

Supplement NEDE-24011-P-A-22-US, November 2015.

1 Modes of operation with thermal limit sets in the COLR

'Operating Region refers to. operation on the Power to Flow map with or without FFWTR or AFTO.

Operation not permitted in the MELLLA+ Region for Reduced Feedwater Temperature conditions as controlled by station procedures.

' Operation in SLO not permitted in the MELLLA+ Region as controlled by station procedures.

Exelon Nuclear - Nuclear Fuels P2C21 Core Operating Limits Report

13.0 REFERENCES

COLR PEACH BOTIOM 2 Rev. 10 Page 22of23

1. "Technical Specifications for Peach Bottom Atomic Power Station Unit 2", Docket No. 50-277, Appendix A to License No. DPR-44.
2. Global Nuclear Fuel Document "Supplemental Reload Licensing Report for Peach Bottom Unit 2, Reload 20, Cycle 21 Extended Power Uprate (EPU)/Maximum Extended Load Line Limit Analysis Plus (MELLLA+)",

GNF Document No. 001N2150-SRLR, Revision 1, January 2015.

3. Global Nuclear Fuel Document "General Electric Standard Application for Reactor Fuel", NEDE-24011-P-A-22, November 2015 and U.S. Supplement NEDE-24011-P-A-22-US, November 2015.
4. Global Nuclear Fuel Document NEDC-33270P Rev. 5, "GNF2 Advantage Generic Compliance with NEDE-24011-P-A (GESTAR II)," May 2013.
5. General Electric Hitachi Document 001N2494-RO, "Peach Bottom EPU Evaluation of Feedwater Temperature vs. Reactor Power for Feedwater Temperature Conditions of Nominal Rated, FWHOOS (Nominal -55°F) and FFWTR (Nominal -90°F)", July 2014. This document is searchable in Exelon EDMS under document number "PEAM-EPU-1 Rev. OA."
6. General Electric Hitachi Document NED0-33720, "Safety Analysis Report for Peach Bottom Atomic Power Station Units 2 & 3 Maximum Extended Load Line Limit Analysis Plus", Revision 0, September 2014.
7. PECO Calculation PE-0173, "Determination of Total Time Required to Initiate the Trip Signal to the EOC-RPT Circuit Breakers Trip Coils and to Complete the Recirculation Pump Trip", Rev. 1dated12/22/98.
8. General Electric Hitachi Document GEH-0000-0107-7348, "GNF2 Fuel Design Cycle-Independent Analyses For Exelon Peach Bottom Atomic Power Station Units 2 and 3", Revision 6, April 2015. This document is searchable in Exelon EDMS under document number "G-080-VC-399 Rev. 3."
9. PECO Calculation PE-0251, Revision 02B, "PRNMS Setpoint Calculation" dated 5/26/15.
10. General Electric Hitachi Document 001N6733-Rl, "Final Evaluation Report Exelon Nuclear Generating Company LLC, Peach Bottom Units 2 & 3, MELLLA+, Asymmetric Feedwater Temperature Operation for EPU/MELLLA+", Revision 1, September 2014. This document is searchable in Exelon EDMS under document number "PEAM-EPU-68 Rev. 1."
11. Global Nuclear Fuel Document 001N6160.1-FBIR, "Fuel Bundle Information Report for Peach Bottom Unit 2 Reload 20 Cycle 21 Extended Power Uprate (EPU)/Maximum Extended Load Line Limit Analysis Plus (MELLLA+) and Extended Power Uprate (EPU)/Maximum Extended Load Line Limit Analysis (MELLLA)",

Revision 1, July 2014.

12. Not Used
13. Not Used
14. Exelon TODI ENSAF ID# ES1400004, Rev. 1, "Final Resolved OPL-3 Parameters for Peach Bottom Unit 2 Cycle 21 -EPU/MELLLA+", May 9, 2014.

Exelon Nuclear

  • Nuclear Fuels COLR PEACH BOTTOM 2 Rev. 10 P2C21 Core Operating Limits Report Page 23of23 APPENDIX A Power/Flow Operating Map for MELLLA+

(Reference 6)

Core Flow ~Db/hr) 0 10 20 30 40 so 60 70 80 90 100 110 120 120 4741 lOO'IW O.TP

]=3951 MWt PL 100% core Flow 110 I

I 4346 ITJITJ CD 100 3951 90 F

110.0 100.0 3556 G

110.0 21.3 H

100.0 21.3 80 I

37.4 21.3 3161 J

83.0 100.0 K

55.0 78.8

'?ft.

70 L

55.0 68.4 2766 I

I t

~

~ 60 Qfil-2370 ::;

c:

j_

I l

I I

I

~

50 I

1975,.*

1--J i

  • ----*-r-40 1580 I

30

-- r--1 i

1185 i

20 I

lca~lilUon tlterlock r*

  • ~ --~*~ [)) [I]

790 I

I I

10 J.....

j 1

~

395

  • -** r-
  • --"i'.

i i

I '

I 0

0 0

10 20 30 40 50 60 70 80 90 100 110 120 Core Flow {°lo)

ATTACHMENT Unit 3 Core Operating Limits Report for Reload 20, Cycle 21, Revision 9

Exelon Nucleati-Nilcle*r fuels P.3C21 Core Operating Limlti Report COLR PJ!d\\<;:H 1J01'TOM 3 Rev. 9 Page 1 of26 CORE OPERATING LIMITS REPORT FOR PEACH B(>-TTOM ATOl\\'IIC POWER STATION UNIT 3 RELOAD 20, CYCLE 21 (This-is a Complete Re-write).

~

Prepared.By: ___________

Date:

4/1/2016, P.Hemy R<viowedBy: ~

  • ~glnetring u.*------

ReviewedBy:~-----/2.5~-----

Oate; 4/1/20~6.

Engineering Safe~ Analysis Independent i1

'11.1. JI ReviewBy: _____

'.;;_:,..u.,.._' _

1'_~*----

Date:

4/1/2016 B. Miller (L

~ --

ApprovedBy: __ -F-.;.;-

'Jl_~

J.J. Tusar Date: 4/5/2016 Station Qualified

/) Jj

~

ftiµiL;*

Date: _L-f_Y -r'_/i_J 6

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating Limits Report Table of Contents 1.0 Tenns and Definitions 2.0 General Information 3.0 MAPLHGR Limits 4.0 MCPR Limits 5.0 Linear Heat Generation Rate Limits 6.0 Rod Block Monitor Setpoints 7.0 Turbine Bypass Valve Parameters 8.0 EOC Recirculation Pump Trip (EOC-RPT) Operability 9.0 Stability Protection COLR PEACH BOTTOM 3 Rev. 9 Page 2of26 Page 5

6 7

8 12 14 15 16 17 10.0 Asymmetric Feedwater Temperature Operation (AFTO) 19 11.0 Modes of Operation 24 12.0 Methodology 24 13.0 References 25 Appendix A (Power/Flow Operating Map for MELLLA+)

26

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating limits Report Revision Revision 9 Revision History COLR PEACH BOITOM 3 Rev. 9 Page 3of26 Description Revised COLR for MELLLA+

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating Limits Report COLR PEACH BOTIOM 3 Rev. 9 Page4of26 List of Tables Table 3-1 MAPLHGR Versus Average Planar Exposure Table 3-2 MAPLHGR Single Loop Operation (SLO) Multiplier Table 4-1 Operating Limit Minimum Critical Power Ratio Table 4-2 Power Dependent MCPR(P) Limit Adjustments and Multipliers Table 4-3 Flow Dependent MCPR Limits MCPR(F)

Table 4-4 SLO Flow Dependent MCPR Limits MCPR(F)

Table 5-1 Linear Heat Generation Rate Limits - U02 rods Table 5-2 Linear Heat Generation Rate Limits - Gad rods Table 5-3 Power Dependent LHGR Multiplier LHGRFAC(P)

Table 5-4 Flow Dependent LHGR Multiplier LHGRFAC(F)

Table 6-1 Rod Block Monitor Setpoints Table 7-1 Turbine Bypass System Response Time Table 7-2 Minimum Required Bypass Valves to Maintain System Operability Table 8-1 Recirculation Pump Trip Response Time Table 9-1 Automatic BSP Setpoints for the Scram Region Table 9-2 Manual BSP Endpoints for Normal Feedwater Temperature Table 9-3 Manual BSP Endpoints for Reduced Feedwater Temperature Page 7

7 9

10 11 11 12 12 13 13 14 15 15 16 17 18 18 Table 10-1 AFTO Thermal Limit Penalties 19 Table 10-2 AFTO Power Dependent LHGR Multiplier LHGRFAC(P) 20F < FWT DELTA$ 55F 20 Table 10-3 AFTO Flow Dependent LHGR Multiplier LHGRFAC(F) 20F < FWT DELTA$ 55F 20 Table 10-4 AFTO Operating Limit Minimum Critical Power Ratio 20F < FWT DEL TA$ 55F 21 Table 10-5 AFTO Power Dependent MCPR Limit Adjustments and Multipliers 22 MCPR(P) 20F < FWT DELTA$ 55F Table 10-6 AFTO Flow Dependent MCPR Limits MCPR(F) 20F < FWT DELTA$ 55F 22 Table 10-7 AFTO MAPLHGR Reduction Factor 23 Table 11-1 Modes of Operation 24 Table 11-2 Additional Equipment Out of Service Modes of Operation 24

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating Limits Report 1.0 Terms and Definitions COLR PEACH BOTTOM 3 Rev. 9 Page 5of26 ABSP Automatic Backup Stability Protection AFfO AFfOLFWH APRM ARTS BASE BOC BSP DSS-CD DTSP EOC EOOS EOR FFWI'R FWHOOS FWf HFCL HTSP ICF ITSP LHGR LHGRFAC(F)

LHGRFAC(P)

LTSP MAPLHGR MCPR MCPR(F)

MCPR(P)

MELLLA MELLLA+

MSIVOOS NCL OLM CPR PLUOOS PROOS RDF RPTOOS RTP RWE SLM CPR SLO TB SOOS TCV/l'SVOOS Asymmetric Feedwater Temperature Operation Asymmetric Feedwater Temperature Operation Loss-of-Feedwater Heating Average Power Range Monitor APRM and RBM Technical Specification Analysis Defines two (2) loop operation with at least seven turbine bypass valves in service and the reactor recirculation pump trip system in service.

Beginning Of Cycle Backup Stability Protection Detect and Suppress Solution - Confinnation Density Rod Block Monitor Downscale Trip Setpoint End of Cycle Equipment Out of Service. An analyzed option that assumes certain equipment to be non-operational End of Rated. The cycle exposure at which reactor power is equal to 100% (3951 MW th) with recirculation system flow equal to 100%, all control rods fully withdrawn, all feedwater heating in service and equilibrium Xenon.

Final Feedwater Temperature Reduction Feedwater Heaters Out of Service Feedwater Temperature High Flow Control Line Rod Block Monitor High Trip Setpoint Increased Core Flow Rod Block Monitor Intermediate Trip Setpoint Linear Heat Generation Rate ARTS LHGR thermal limit flow dependent adjustments and multipliers ARTS LHGR thermal limit power dependent adjustments and multipliers Rod Block Monitor Low Trip Setpoint Maximum Average Planar Linear Heat Generation Rate Minimum Critical Power Ratio ARTS MCPR thermal limit flow dependent adjustments and multipliers ARTS MCPR thermal limit power dependent adjustments and multipliers Maximum Extended Load Line Limit Analysis Maximum Extended Load Line Limit Analysis Plus Main Steam Isolation Valve Out of Service Natural Circulation Line Operating Limit Minimum Critical Power Ratio Power Load Unbalance Out of Service Pressure Regulator Out of Service Rated Drive Flow Recirculation Pump Trip Out of Service Rated Thermal Power Rod Withdrawal Error Safety Limit Minimum Critical Power Ratio Single Loop Operation Turbine Bypass Valves Out of Service Turbine Control Valve/Turbine Stop Valve Out of Service

Exelon Nuclear - Nuclear Fuels P3C21 Core Operating Umits Report 2.0 General Information COLR PEACH BOTTOM 3 Rev. 9 Page 6of26 This report provides the following cycle-specific parameter limits for Peach Bottom Atomic Power Station Unit 3 CYCIE 21 (RELOAD 20):

Maximum Average Planar Linear Heat Generation Rate (MAPLHGR)

Single Loop Operation (SLO) MAPI.RGR multipliers Operating Limit Minimum Critical Power Ratio (OLMCPR)

ARTS MCPR thennal limit adjustments and multipliers Single Loop Operation (SLO) MCPR adjustment Linear Heat Generation Rate (LHGR)

ARTS LHGR thennal limit multipliers Single Loop Operation (SLO) l.RGR multipliers Rod Block Monitor (RBM) Analytical Limits, Allowable Values and MCPR Limits Turbine Bypass Valve Parameters EOC Recirculation Pump Trip (EOC-RPT) Parameters Stability Protection Setpoints Asymmetric Feedwater Temperature Operation (AFTO) thennal limit penalties These values have been determined using NRC-approved methodology and are established such that all applicable limits of the plant safety analysis are met. SLO, FWHOOS operation, and FFWTR operation are not permitted in the MELLLA+ Region as controlled by station procedures. For the MELLLA+ Region, a specific definition ofFWHOOS is provided in Facility Operating License (FOL) Section 2.C(l6).

This report provides cycle-specific Operating Limit MCPR, LHGR, MAPI.RGR thermal limits, and related information for the following conditions:

All points in the operating region of the power/flow map including MEULA+ Region down to 83%

of rated core flow during full power (3951 MWt) operation (Appendix A)

Increased Core Flow (ICF), up to 110% of rated core flow End-of-Cycle Power Coastdown to a minimum power level of 40%

Feedwater Heaters Out of Service (FWHOOS) to 55° F temperature reduction Fmal Feedwater Temperature Reduction (FFWTR) between End-of-Rated (EOR) and End-of-Cycle (EOC) to 90° F temperature reduction (4th and 5th stage FWHOOS)

Asymmetric Feedwater Temperature Operation (AFTO)

ARTS provides for power and flow-dependent thermal limit adjustments and multipliers that allow for a more reliable administration of the MCPR and l.RGR thermal limits. The OLMCPR is determined by the cycle-specific reload analyses in Reference 2. Rated LHGR values are obtained from the bundle-specific thermal-mechanical analysis. Supporting documentation for the ARTS-based limits is provided in Reference 2. The Allowable Values documented in Reference 5 for feedwater temperature as a function of thermal power for both FWHOOS and FFWTR are specified in the appropriate Peach Bottom procedures.

Also note that the following description of MAPI.RGR, LHGR and MCPR limits pertain to NON - AFTO conditions. A separate description of AFTO limits and their associated ARTS tables are located in Section 10.

Preparation of this report was perfonned in accordance with Exelon Nuclear procedures. This report is provided to the NRC in accordance with Technical Specification 5.6.5 of Reference 1 and contains all thermal limit parameters related to the implementation of the ARTS Improvement Program and MELLLA+ for Peach Bottom Unit 3 Cycle 21.

The "BASE" thennal limit values shown in tables are for nonnal two loop operation with at least the minimum number of turbine bypass valves in service per Section 7.0, the reactor recirculation pump trip system in service, the power load unbalance device in service, and both pressure regulators in service.

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating Limits Report 3.0 MAPLHGR LIMITS 3.1 Technical Specification Section 3.2.1, 3.3.4.2, 3.4.1 and 3.7.6 3.2 Description COLR PEACH BOTTOM 3 Rev. 9 Page 7 of26 The MAPLHGR limits (kW/ft) obtained from the emergency core cooling system (ECCS) analysis are provided in Table 3-1. The MAPLHGR limits comprise a given fuel type as a function of average planar exposure. The MAPLHGR tables are used when hand calculations are required. All MAPLHGR values for GNF2 as a function of axial location and average planar exposure shall be less than or equal to the applicable MAPLHGR limits for GNF2 fuel and lattice type. These MAPLHGR limits are specified in Reference 2 and the process computer databank. The SLO MAPLHGR multiplier is provided in Table 3-2 per Reference 2 and must be applied to the Table 3-1 limits when operating in SLO. The impact of AFTO on MAPLHGR is addressed in Section 10.

TABLE3-1 MAPLHGR Versus Average Planar Exposure (Reference 2)

Average Planar Exposure MAPLHGR Limit (GWD/ST)

(kW/ft) 0.0 13.78 17.52 13.78 60.78 7.50 63.50 6.69 TABLE3-2 MAPLHGR Single Loop Operation (SLO) Multiplier (Reference 2)

SLO Multiplier 0.73

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating Limits Report 4.0 MCPR LIMITS

. 4.1 Technical Specification Section 2.1.1.2, 3.2.2, 3.3.4.2, 3.4.1and3.7.6 4.2 Description COLR PEACH BOTTOM 3 Rev. 9 Page 8of26 The Operating Limit MCPR (OLMCPR) for GNF2 fuel is provided in Tables 4-1and4-2. These values are determined by the cycle-specific fuel reload analyses in Reference 2. Control rod scram time verification is required as per Technical Specification 3.1.4, "Control Rod Scram Times". Tau, a measure of scram time performance to notch position 36 throughout the cycle, is determined based on the cumulative scram time test results. The calculation of Tau shall be performed in accordance with site procedures. Linear interpolation shall be used to calculate the OLMCPR value if Tau is between 0.0 (Tau Option B) and 1.0 (Tau Option A).

Separate OLMCPR values are presented in Table 4-1 for the following conditions:

  • TBS In-Service (per section 7.0), RPT In-Service (per section 8.0), PLU/PR In-Service, and maximum FFWTR of 90 °F (a.k.a. "BASE")
  • TBS Out-of-Service (per section 7.0), RPT In-Service (per section 8.0), PLU/PR In-Service, and maximum FFWTR of 90 °F
  • TBS In-Service (per section 7.0), RPT In-Service (per section 8.0), PLU/PR Out-of-Service, and maximum FFWTR of 90°F
  • TBS In-Service (per section 7.0), RPT Out-of-Service (per section 8.0), PLU/PR In-Service, and maximum FFWTR of 90 °F The ARTS-based power-dependent MCPR limits are provided in Table 4-2. Table 4-2 is valid for a maximum temperature reduction of 90 °F for FFWTR operation (bounding for FWHOOS operation). The flow-dependent MCPR limits are provided in Tables 4-3 and 4-4. Table 4-3 is valid for dual loop operating conditions with symmetric feedwater temperature operation and Table 4-4 is valid for single loop operating conditions with symmetric feedwater temperature operation. The impact of AFTO on MCPR is addressed in Section 10. For PR/PLUOOS +

TBSOOS and PR/PLUOOS + RPTOOS conditions, the limits are listed in Section 10, these values are bounding for non-AFTO conditions.

Exelon Nuclear - Nuclear Fuels P3C21 Core Operating limits Report TABLE4-1 COLR PEACH BOTI'OM 3 Rev. 9 Page 9of26 Operating Limit Minimum Critical Power Ratio (Reference 2)

SCRAM Cycle Exuosure Time

<EOR-2523

~EOR-2523 EOOS Combination Option(l>

MWd/ST MWd/ST B

1.38 1.41 BASE A

1.45 1.49 B

1.43 1.43 BASESL0<2>

A 1.45 1.49 B

1.42 1.46 RPTOOS A

1.59 1.63 B

1.43 1.46 RPTOOS SL0<2>

A 1.59 1.63 B

1.38 1.41 PR/PLUOOS A

1.45 1.49 B

1.43 1.43 PR/PLUOOS SL0<2>

A 1.45 1.49 B

1.42 1.43 TB SOOS A

1.49 1.52 B

1.43 1.43 TBSOOS SLO <2>

A 1.49 1.52 (1) When Tau does not equal O or 1, use linear interpolation.

(2) For single-loop operation, the MCPR operating limit is the same as the analyzed limiting two loop value. However a minimum value of 1.43 is required to obtain an OLMCPR limit set by the Single Loop Operation Recirculation Pump Seizure Event (Reference 2).

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating limits Report TABLE4-2 COLR PEACH BO'ITOM 3 Rev. 9 Page 10of26 Power Dependent MCPR(P) Limit Adjustments and Multipliers (Symmetric Feedwater Heating)

(Reference 2)

Core Core Thermal Power ( % of rated)

Flow 0

23

<26.7

?.26.7 40 55 65 85 100 EOOS Combination

(% oi:

rated Operating Limit MCPR Operating Limit MCPR Multiplier, Kp

)

_s60 2.67 2.67 Base

>60 2.99 2.99 2.60 2.83 1.352 1.352 1.317 1.131 1.082 1.000

_s60 2.67 2.67 2.60 1.352 1.317 1.131 1.082 1.000 BaseSLO

>60 2.99 2.99 1.352 2.83 RPTOOS

_s60 2.67 2.67 2.60 1.352 1.352 1.317 1.131 1.082 1.000

>60 2.99 2.99 2.83 RPTOOSSLO

_s60 2.67 2.67 2.60 1.352 1.352 1.317 1.131 1.082 1.000

>60 2.99 2.99 2.83 PR/PLUOOS

_s60 2.67 2.67 2.60 1.392 1.352 1.317 1.210 1.147 1.000

>60 2.99 2.99 2.83 PR/PLUOOSSLO

_s60 2.67 2.67 2.60 1.392 1.317 1.210 1.147 1.000

>60. 2.99 2.99 1.352 2.83

_s60 3.64 3.64 3.25 TB SOOS

>60 4.15 4.15 1.659 1.479 1.373 1.155 1.082 1.000 3.78

_s60 3.64 3.64 3.25 TBSOOSSLO 1.659 1.479 1.373 1.155 1.082 1.000

>60 4.15 4.15 3.78

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating Limits Report TABLE4-3 COLR PEACH BOTIOM 3 Rev. 9 Page 11of26 Flow Dependent MCPR Limits MCPR(F)

(Symmetric Feedwater Heating)

(Reference 2)

Core Flow MCPR(F)

(%rated)

Limit 0.0 1.75 30.0 1.57 79.0 1.28 110.0 1.28 TABLE4-4 SLO Flow Dependent MCPR Limits MCPR(F)

(Symmetric Feedwater Heating)

(Reference 2)

Core Flow MCPR(F)

(%rated)

Limit 0.0 1.75 30.0 1.57 79.0 1.28 110.0 1.28

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating limits Report COLR PEACH BOTTOM 3 Rev. 9 Page 12of26 5.0 LINEAR HEAT GENERATION RATE LIMITS 5.1 Technical Specification Section 3.2.3, 3.3.4.2, 3.4.1and3.7.6 5.2 Description The LHGR values for GNF2 fuel type are provided in Tables 5-1and5-2. The ARTS-based LHGR power-dependent multipliers are provided in Table 5-3. Table 5-3 is valid for a maximum temperature reduction of 90° F for FFWTR operation (bounding for FWHOOS operation). The flow-dependent multipliers are provided in Table 5-4 as a function of the number of recirculation loops in operation. The SLO LHGR multiplier is provided and accounted for in Table 5-4. The power-and flow-dependent LHGR multipliers were obtained from Reference 2. The impact of AFTO on LHGR is addressed in Section 10. For PR/PLUOOS.+ TBSOOS and PR/PLUOOS + RPTOOS conditions, the limits are listed in Section 10, these values are bounding for non-AFTO conditions. The power and flow dependent LHGR multipliers are sufficient to provide adequate protection for the off-rated conditions from an ECCS-LOCA analysis perspective.

TABLES-1 Linear Heat Generation Rate Limits - U02 rods (References 4 and 11)

Fuel Type LHGRLimit GNF2 See Appendix B of Reference 4 TABLES-2 Linear Heat Generation Rate Limits - Gad rods (References 4 and 11)

Fuel Type LHGRLimit GNF2 See Appendix B of Reference 4

Exelon Nuclear

  • Nuclear Fuels P3C2 l Core Operating Limits Report COLR PEACH BOTTOM 3 Rev. 9 Page 13of26 EOOS Combination Base BaseSLO RPTOOS RPTOOSSLO PR/PLUOOS PR/PLUOOSSLO TB SOOS TBSOOSSLO TABLE5-3 Power Dependent LHGR Multiplier LHGRFAC(P)

(Symmetric Feedwater Heating)

(Reference 2)

Core Thermal Power ( % of rated)

Core Flow 0

23

<.26.7

~6.7 40 55

(%of rated)

LHGRFAC(P) Multiplier

60 0.508 0.508 0.522 0.748 0.756

>60 0.508 0.508 0.522

60 0.508 0.508 0.522 0.748 0.756

>60 0.508 0.508 0.522

60 0.508 0.508 0.522

>60 0.508 0.508 0.748 0.756 0.522

60 0.508 0.508 0.522

>60 0.748 0.756 0.508 0.508 0.522

60 0.508 0.508 0.522

>60 0.508 0.508 0.522 0.620 0.696

60 0.508 0.508 0.522

>60 0.508 0.508 0.522 0.620 0.696

60 0.397 0.397 0.442

>60 0.397 0.397 0.417 0.635 0.655

60 0.397 0.397 0.442 0.635 0.655

>60 0.397 0.397 0.417 TABLE5-4 Flow Dependent LHGR Multiplier LHGRFAC(F)

(Symmetric Feedwater Heating)

(Reference 2)

Core Flow ( % of rated) 0.771 0.771 0.771 0.771 0.751 0.751 0.714 0.714 EOOS Combination 0

30 33.6 70 80 LHGRFAC(F) Multiplier Dual Loop 0.506 0.706 0.730 0.973 1.000 Single Loop 0.506 0.706 0.730 0.730 0.730 65 85 0.817 0.959 0.817 0.959 0.817 0.959 0.817 0.959 0.817 0.959 0.817 0.959 0.817 0.930 0.817 0.930 110 1.000 0.730 100 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating Umits Report 6.0 ROD BLOCK MONITOR SETPOINTS 6.1 Technical Specification Section 3.3.2.1 6.2 Description COLR PEACH BOTTOM 3 Rev. 9 Page 14 of 26 The RBM power-biased Analytical Limits, Allowable Values and MCPR Limits are provided in Table 6-1 with supporting documentation in References 2 and 9. The values correspond to the OLMCPR values provide in Table 4-1.

Power Level LTSP ITSP HTSP INOP TABLE6-1 Rod Block Monitor Setpoints (References 2 and 9)

Analytical Limit(l>

Allowable Value<1>

120.0%

118.2%

115.2%

113.4%

110.2%

108.4%

NIA NIA MCPRLimit

< 1.70 <2>

< 1.40 <3>

< 1.70 (2)

< 1.40 <3>

< 1.70 (2)

< 1.40 <3>

< 1.70 (2)

< 1.40 l3>

(1) These setpoints (with RBM filter time constant between 0.1 seconds and 0.55 seconds) are based on a cycle-specific rated RWE MCPR limit which is less than or equal to the minimum cycle OLMCPR based on other events (see COLR References 2 and 9).

(2) This is the MCPR limit (given THERMAL POWER is >28.4% and < 90%) below which the RBM is required to be OPERABLE (see COLR Reference 2 and TS Table 3.3.2.1-1).

(3) This is the MCPR limit (given THERMAL POWER is > 90%) below which the RBM is required to be OPERABLE (see COLR Reference 2 and TS Table 3

. 3~2.1-1).

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating Limits Report 7.0 TURBINE BYPASS VAL VE PARAMETERS 7.1 Technical Specification Section 3.7.6 7.2 Description COLR PEACH BOTTOM 3 Rev. 9 Page 15of26 The operability requirements for the steam bypass system are governed by Technical Specification 3.7.6. If the requirements cannot be met, the appropriate power and flow dependent limits for Turbine Bypass System Out-of-Service (TBSOOS) must be used. Additionally, the OLMCPR forTBSOOS must be applied. Table 7-1 includes the Turbine Bypass Valve response time parameters. The minimum number of bypass valves to maintain system operability is provided in Table 7-2 per Reference 14.

TABLE7-1 Turbine Bypass System Response Time (Reference 14)

Maximum delay time before start of bypass valve opening following initial turbine inlet valve movement0>

Maximum time after initial turbine inlet valve movement0> for bypass valve position to reach 80% of full flow (includes the above delay time) 0.10 sec 0.30 sec (1)

Fust movement of any TSV.Q! any TCV ID: generation of the turbine bypass valve flow signal (whichever occurs first)

TABLE7-2 Minimum Required Bypass Valves To Maintain System Operability (Reference 14)

Reactor Power No. of Valves in Service P~23%

7

Exelon Nuclear *Nuclear Fuels P3C21 Core Operating limits Report COLR PEACH BOTTOM 3 Rev. 9 Page 16 of 26 8.0 EOC RECffiCULATION PUMP TRIP (EOC-RPT) OPERABILITY 8.1 Technical Specification Section 3.3.4.2 8.2 Description The operability requirements for the EOC Recirculation Pump Trip are governed by Technical Specification 3.3.4.2. If the requirements cannot be met, the appropriate power and flow dependent limits for EOC Recirculation Pump Trip Out Of Service (RPTOOS) must be used.

Additionally, the OLMCPR for RPTOOS must be applied. Table 8-1 includes the total RPT response time parameter.

TABLES-1 Recirculation Pump Trip Response Time (Reference 14)

Total Recirculation Pump Trip Response Time The time from when the turbine valves (turbine control valve or turbine stop valve) start to close until complete arc suppression of the EOC-RPT circuit breakers as described in Reference 7.

0.175 sec

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating Limits Report 9.0 STABILITY PROTECTION 9.1 Technical Specification Section 3.3.1.1, Table 3.3.1.1-1Function2.f, Section 5.6.5 9.2 Description COLR PEACH BOTTOM 3 Rev. 9 Page 17of26 Per Reference 2, the Cycle 21 DSS-CD SAD Setpoint was confirmed to be 1.10 for DLO and SLO.

The Automatic Backup Stability Protection (BSP) Setpoints are provided in Table 9-1. The Manual BSP Endpoints for Normal Feedwater Temperature and Reduced Feedwater Temperature are provided in Tables 9-2 and Table 9-3.

TABLE9-1 Automatic BSP Setpoints for the Scram Region (Reference 2)

Parameter Symbol Value Slope of ABSP APRM flow-mTrip 1.39 biased trip linear segment.

ABSP APRM flow-biased trip setpoint power intercept.

Constant Power Line for Trip PBsP-Trip 39.9 %RTP from zero Drive Flow to Flow Breakpoint value.

ABSP APRM flow-biased trip setpoint drive flow intercept.

WBSP-Trip 46.5 %RDF Constant Flow Line for Trip.

Flow Breakpoint value WBsP-Break 20.0%RDF

Exelon Nuclear *Nuclear Fuels P3C21 Core Operating Limits Report COLR PEACH BOTTOM 3 Rev. 9 Page 18of26 Endpoint Al Bl A2 B2 TABLE 9.2<1>

Manual BSP Endpoints for Normal Feedwater Temperature (Reference 2)

Power(%)

Flow(%)

Definition 76.7 52.2 Scram Region Boundary, MELLLA+

Extension 39.9 31.0 Scram Region Boundary, NCL 64.5 50.0 Controlled Entry Region Boundary, HFCL 28.l 30.l Controlled Entry Region Boundary, NCL Note: The BSP Boundary for Nonna! and Reduced Feedwater Temperature is defined by the MELLLA boundary line, per Reference 2.

TABLE 9.3<1>

Manual BSP Endpoints for Reduced Feedwater Temperature (Reference 2)

Endpoint Power(%)

Flow(%)

Definition Al 65.7 51.5 Scram Region Boundary, HFCL Bl 34.9 30.7 Scram Region Boundary, NCL A2 67.3 53.5 Controlled Entry Region Boundary, HFCL B2 28.1 30.1 Controlled Entry Region Boundary, NCL Note: The BSP Boundary for Normal and Reduced Feedwater Temperature is defined by the MELLLA boundary line, per Reference 2.

(1) Station may elect to place additional administrative margin on the endpoints provided in Table 9-2 and Table 9-3.

Exelon Nuclear *Nuclear Fuels P3C21 Core Operating Limits Report COLR PEACH BOTTOM 3 Rev. 9 Page 19 of 26 10.0 ASYMMETRIC FEEDWATER TEMPERATURE OPERATION (AFTO)

Asymmetric feedwater heating (resulting from removing a heater string, or individual feedwater heaters, from operation) is the result of the specific configuration of the feedwater lines at Peach Bottom. A reduction in heating in either the 'A' or the 'C' heater strings will result in a temperature mismatch between the feedwater flows entering the opposite sides of the reactor vessel. This temperature mismatch may result in errors in the thermal limit values calculated by the core monitoring system. Thermal limit values for all conditions and events are impacted by these errors excluding SLO conditions. The P3C21 COLR Rev. 8 was the first COLR to no longer require implementation of SLO AFTO penalty files for this unit. The station no longer requires SLO AFTO files or penalties due to a 3D MONICORE upgrade required for EPU operation. Asymmetric feedwater temperature operation (AFTO) is defined as operation in a feedwater heater/string configuration that results in a specified threshold difference as described in Reference 10. To simplify the implementation of the AFTO limits, only the maximum AFTO penalties indicated in Table 10-1 will be implemented when the threshold asymmetry temperature (temperature above which a penalty is required) is exceeded. This will minimize the number of AFTO thermal limit tables in the COLR and core monitoring system.

40F < FWT DELTA$ 55F 30F < FWT DELTA $40F 20F < FWT DELTA$ 30F OF< FWT DELTA$ 20F TABLE 10-1 AFTO Thermal Limit Penalties (Asymmetric Feedwater Heating)

(Reference 10)

MFLCPR 3%

2%

2%

No Penalty LHGRLIMITS MFLPD/MAPRAT 4%

3%

2%

No Penalty The ARTS-based LHGR power-dependent multipliers for AFTO operation are provided in Table 10-2. The flow-dependent multipliers for AFTO in DLO are provided in Table 10-3. The power-and flow-dependent LHGR multipliers were obtained from Reference 2 and were adjusted with the appropriate penalties displayed in Table 10-1 as per Reference 10. PR/PLUOOS + TBSOOS and PR/PLUOOS + RPTOOS values were obtained by taking the most limiting OLMCPR values of the two EOOS conditions, these values are bounding for non-AFTO conditions. The maximum feedwater temperature difference allowed without a thermal limit penalty is 20 °F. Once the temperature difference exceeds 20 °F the maximum penalties from Table 10-1 are applied to the thermal limits. Additionally, no LHGR penalties are required for asymmetric feedwater temperature option while in SLO as previously discussed.

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating limits Report COLR PEACH BOTTOM 3 Rev. 9 Page20of26 TABLEl0-2 AFTO Power Dependent LHGR Multiplier LHGRFAC(P) 20F < FWT DELTA~ 55F (Asymmetric Feedwater Heating)

(References 2 and 10)

Core Core Thermal Power ( % of rated)

EOOS Combination Flow 0

23

<26.7

?.26.7 40 55 65

(%of rated)

LHGRFAC(P) Multiplier

$60 0.488 0.488 0.501 Base 0.718 0.726 0.740 0.784

>60 0.488 0.488 0.501

$60 0.488 0.488 0.501 RPTOOS 0.718 0.726 0.740 0.784

>60 0.488 0.488 0.501

$60 0.488 0.488 0.501 PR/PLUOOS 0.595 0.668 0.721 0.784

>60 0.488 0.488 0.501

$60 0.381 0.381 0.424 TB SOOS 0.610 0.629 0.685 0.784

>60 0.381 0.381 0.400

$60 0.381 0.381 0.424 PR/PLUOOS + TBSOOS 0.595 0.629 0.685 0.784

>60 0.381 0.381 0.400

$60 0.488 0.488 0.501 PR/PLUOOS + RPTOOS 0.595 0.668 0.721 0.784

>60 0.488 0.488 0.501 TABLE 10-3 AFTO Flow Dependent LHGR Multiplier LHGRFAC(F) 20F < FWT DELTA~ 55F (Asymmetric Feedwater Heating)

(References 2 and 10)

Core Flow ( % of rated)

EOOS Combination 0

I 30 I 33.60 I 70 I

80 I

LHGRFAC(F) Multiplier 85 0.921 0.921 0.921 0.893 0.893 0.921 110 Dual Loop 0.486 I 0.678 I 0.701 I 0.934 I 0.960 I 0.960 100 0.960 0.960 0.960 0.960 0.960 0.960

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating llmits Report MCPRLIMITS COLR PEACH BO'ITOM 3 Rev. 9 Page 21of26 The OLMCPRs during asymmetric feedwater temperature operation with a feedwater temperature difference greater than 20 °F are provided in Table 10-4. The ARTS-based power-dependent MCPR limits for use during AFTO conditions are provided in Table 10-5. The flow-dependent MCPR limits for AFTO are provided in Table 10-6.

The power and flow-dependent OLMCPR curves were obtained from Reference 2 and were adjusted with a 3% penalty for feedwater temperature difference greater than 20 °F as displayed in Table 10-1 as per Reference 10. PR/PLUOOS + TBSOOS and PR/PLUOOS + RPTOOS values were obtained by taking the most limiting OLMCPR values of the two BOOS conditions, these values are bounding for non-AFTO conditions. No MCPR penalties are required for asymmetric temperature differentials less than or equal to 20 °F. Additionally, no MCPR penalties are required for asymmetric feedwater temperature option while in SLO as previously discussed.

TABLEl0-4 AFTO Operating Limit Minimum Critical Power Ratio 20F < FWT DELTAS 55F (Asymmetric Feedwater Heating)

(References 2 and 10)

SCRAM Cycle Exoosure Time

<EOR-2523

~EOR-2523 EOOS Combination Option<1>

MWd/ST MWd/ST BASE B

1.42 1.45 A

1.49 1.53 RPTOOS B

1.46 1.50 A

1.64 1.68 PR/PLUOOS B

1.42 1.45 A

1.49 1.53 TBSOOS B

1.46 1.47 A

1.53 1.57 PR/PLUOOS + TBSOOS B

1.46 1.47 A

NIA NIA PR/PLUOOS + RPTOOS B

1.46 1.50 A

NIA NIA (1) When Tau does not equal O or 1, use linear interpolation.

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating limits Report TABLE 10-5 COLR PEACH BOTTOM 3 Rev. 9 Page 22 of26 AFTO Power Dependent MCPR Limit Adjustments And Multipliers MCPR(P) 20F < FWT DELTA::; SSF (Asymmetric Feedwater Heating)

(References 2 and 10)

Core Core Thermal Power ( % of rated)

EOOS Combination Flow 0

23

<.26.7

?:.26.7 40 55 65 85

(%of 100 rated) Operating Limit MCPR Operating Limit MCPR Multiplier, Kp

.$ 60 2.75 2.75 2.68 1.131 Base 1.352 1.352 1.317

>60 3.08 3.08 2.91

.$ 60 2.75 2.75 2.68 RPTOOS

>60 3.08 3.08 2.91 1.352 1.352 1.317 1.131

_s60 2.75 2.75 2.68

.PR/PLUOOS

>60 3.08 2.91 1.392 1.352 1.317 1.210 3.08

.$ 60 3.75 3.75 3.35 TB SOOS

>60 4.27 3.89 1.659 1.479 1.373 1.155 4.27 PR/PLUOOS + TBSOOS

_s60 3.75 3.75 3.35

>60 4.27 3.89 1.659 1.479 1.373 1.210 4.27 PR/PLUOOS + RPTOOS

.$ 60 2.75 2.75 2.68 1.392 1.352 1.317 1.210

>60 3.08 3.08 2.91 TABLE 10-6 AFTO Flow Dependent MCPR Limits MCPR(F) 20F < FWT DELTA$ 55F (BOC to EOC)(Asymmetric Feedwater Heating)

(References 2 and 10)

Flow MCPR(F)

(%rated)

Limit 0.0 1.80 30.0 1.62 79.0 1.32 110.0 1.32 1.082 1.000 1.082 1.000 1.147 1.000 1.082 1.000 1.147 1.000 1.147 1.000

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating limits Report MAPLHGR LIMITS COLR PEACH BOTI'OM 3 Rev. 9 Page 23 of 26 An appropriate penalty must be applied to MAPLHGR limits under asymmetric feedwater temperature operation (AFrO) for varying temperature differentials as displayed in Table 10-1 as per Reference 10. No MAPLHGR penalties are required for asymmetric feedwater temperature option while in SLO as previously discussed.

TABLE 10-7 AFTO MAPLHGR Reduction Factor (Asymmetric Feedwater Heating)

(References 2 and 10)

AFTO Reduction Factor 20F<FWTDELTA~55F I 0.960

Exelon Nuclear *Nuclear Fuels P3C21 Core Operating Llmits Report COLR PEACH BOTTOM 3 Rev. 9 Page 24of26 11.0 MODES OF OPERATION TABLE 11-1 Modes of Operation (Reference 2)

Supported Operating EOOS Options1 Reeion2 Base, Option A or B Yes Base SLO, Option A or B Yes3 TBSOOS, Option A or B Yes TBSOOS SLO, Option A or B Yes3 RPTOOS, Option A or B Yes RPTOOS SLO, Option A or B Yesj PLUOOS, Option A or B Yes PLUOOS SLO, Option A or B Yes3 PROOS, Option A or B Yes PROOS SLO, Option A or B Yes3 PR/PLUOOS and TBSOOS, Option B Yes PR/PLUOOS and RPTOOS, Option B Yes TBSOOS and RPTOOS, Option A or B No TBSOOS and RPTOOS SLO, Option A or B No TABLE 11-2 Additional Equipment Out of Service Modes of Operation EOOS TCVffSVOOS (controlled via station procedures)

MSIVOOS (controlled via station procedures)

AFTO LFWH (controlled via station procedures) 12.0 METHODOLOGY The analytical methods used in determining the core operating limits have been previously reviewed and approved by the NRC, specifically those described in the following documents:

1. "General Electric Standard Application for Reactor Fuel, NEDE-24011-P-A-22, November 2015 and U.S. Supplement NEDE-24011-P-A-22-US, November 2015.

Modes of operation with thermal limit sets in the COLR

' Operating Region refers to operation on the Power to Flow map with or without FFWTR or AFTO.

Operation not permited in the MELLLA+ Region for Reduced Feedwater Temperature conditions as controlled by station procedures.

3 Operation in SLO not permitted in the MELLLA+ Region as controlled by station procedures.

Exelon Nuclear

  • Nuclear Fuels P3C2 I Core Operating limits Report

13.0 REFERENCES

COLR PEACH BOTTOM 3 Rev. 9 Page 25 of 26

1. "Technical Specifications for Peach Bottom Atomic Power Station Unit 3," Docket No. 50-278, Appendix A to License No. DPR-56.
2. Global Nuclear Fuel Document "Supplemental Reload Licensing Report for Peach Bottom Unit 3, Reload 20, Cycle 21 Extended Power Uprate (EPU)/Maximum Extended Load Line Limit Analysis Plus (MELLLA+)," GNF Document No. 001N3881, Revision 0, July 2015.
3. Global Nuclear Fuel Document "General Electric Standard Application for Reactor Fuel," NEDE-24011-P-A-22, November 2015 and U.S. Supplement NEDE-24011-P-A-22-US, November 2015.
4. Global Nuclear Fuel Document NEDC-33270P Rev. 5, "GNF2 Advantage Generic Compliance with NEDE-24011-P-A (GESTAR II)," May 2013.
5. General Electric Hitachi Document 001N2494-RO, "Peach Bottom EPU Evaluation of Feedwater Temperature vs. Reactor Power for Feedwater Temperature Conditions of Nominal Rated, FWHOOS (Nominal -55°F) and FFWTR (Nominal -90°F)," July 2014. This document is searchable in Exelon EDMS under document number "PEAM-EPU-1 Rev. OOA."
6. General Electric Hitachi Document NED0-33720, "Safety Analysis Report for Peach Bottom Atomic Power Station Units 2 & 3 Maximum Extended Load Line Limit Analysis Plus", Revision 0, September 2014.
7. PECO Calculation PE-0173, "Determination of Total Time Required to Initiate the Trip Signal to the EOC-RPf Circuit Breakers Trip Coils and to Complete the Recirculation Pump Trip," Rev. 1 dated 12/22/98.
8. NotUsed.
9. PECO Calculation PE-0251, Revision 2B, "PRNMS Setpoint Calculation," dated 5/26/15.
10. General Electric Hitachi Document 001N6733-Rl, "Final Evaluation Report Exelon Nuclear Generating Company LLC, Peach Bottom Units 2 & 3, MELLLA+, Asymmetric Feedwater Temperature Operation for EPU/MELLLA+," Revision l, September 2014. This document is searchable in Exelon EDMS under document number "PEAM-EPU-68 Rev. l."
11. Global Nuclear Fuel Document 002N8938, Revision 0, "Fuel Bundle Information Report for Peach Bottom Unit 3 Reload 20 Cycle 21 Extended Power Uprate (EPU)/Maximum Extended Load Line Limit Analysis Plus (MELLLA+) and Extended Power Uprate (EPU)/Maximum Extended Load Line Limit Analysis (MELLLA)," July 2015.
12. Not Used
13. Not Used
14. Exelon TOOi ENSAF ID# ES1500001, Rev. 0, "Final Resolved OPL-3 Parameters for Peach Bottom Unit 3 Cycle 21: EPU/MELLLA+," February 17, 2015.

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating Limits Report 0

10 20 30 APPENDIX A COLR PEACH BOTIOM 3 Rev. 9 Page 26 of 26 Power/Flow Operating Map for MELLLA+

(Reference 6)

Core Flow (l\\Db/hr) 40 50 60 70 80 90 100 110 120 120..i-..._._...._.l-l-l--+-l-+-l-......._.._._...._........i..........._~_............ ~

..............._._~

, _._........ 1-.1._,_..._._.__,_.......i............_.1-1_._,....... ~

....... 4741 100% a.TP

!= 3951 MWt

,I i-.,,.l't.-.---'-~~-=-=r==~-,-,,.-~ 100%. Core* FiOw-*- != 102.5 Mlb hr 1

I i

i OJ mm m 1..D----+---:::O:l>----0 110 t

~-

  • l..

~ -

seed 100 54.9 4346 3951 D

100.0 E

100.0 90 F

100.0 3556 G

110.D 21.3 H

100.D 21.3 80 37.4 21.3 3161 83.0 100.0 K

55.0 78.8

?f.

70 t :=

60

=!

"i J 50 55.0 68.4 L

2766

~

==

2370 e ti 1975 ~

40 1580 30 1185 20 790 10 395 0

0 0

10 20 30 40 50 60 70 80 90 100 110 120 Core Flow(%)

Exelon Generation May 6, 2016 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington DC 20555-0001 Peach Bottom Atomic Power Station, Units 2 and 3 Renewed Facility Operating License Nos. DPR-44 and DPR-56 NRC Docket Nos. 50-277 and 50-278 TS 5.6.5.d

Subject:

Issuance of the Core Operating Limits Reports for Implementation of the Maximum Extended Load Line Limit Analysis Plus Analysis Enclosed are copies of Revision 10 and Revision 9 of the Core Operating Limits Reports (COLRs) for Peach Bottom Atomic Power Station (PBAPS) Units 2 and 3, respectively. These revisions incorporate the implementation of the Maximum Extended Load Line Limit Analysis Plus license amendments 305/307.

The COLR revisions are being submitted to the NRC as required by the PBAPS, Units 2 and 3 Technical Specifications (TS) Section 5.6.5.d.

If you have any questions concerning this letter, please contact Dave Foss at (717) 456-4311.

Site Vice President Peach Bottom Atomic Power Station CCN: 16-41 Attachments Unit 2 Core Operating Limits Report for Reload 20, Cycle 21, Revision 10 Unit 3 Core Operating Limits Report for Reload 20, Cycle 21, Revision 9 cc:

Regional Administrator, Region I, USNRC (without attachments)

USNRC Senior Resident Inspector, PBAPS (without attachments)

Project Manager-PBAPS, USNRC (with attachments)

R. R. Janati, Pennsylvania Bureau of Radiation Protection (without attachments)

S. T. Gray, State of Maryland (without attachments)

ATTACHMENT Unit 2 Core Operating Limits Report for Reload 20, Cycle 21, Revision 10

Exeloa Nuclear* Nuclear Fuelll P2C2 l Core Operating Limits Report COLR PEACH BOTIOM 2 Rev. 10 Page 1 of23 CORE OPERATING Lll\\flTS REPORT FOR PEACH BOTTOM ATOl\\flC POWER STATION UNIT 2 Prepared By:

Co-Prepared By:

Reviewed By:

Reviewed By:

Independent Review By:

Approved By:

Station Qualified Reviewer:

RELOAD 20, CYCLE 21 (fhis is a Complete Re-write)

T.Bement Q~

~:s.

P.Hemy Engineering SafetY Analysis

~

C.Burns

~

.:ef "4M/ -~

~

J.J.Tusar Date: 1/29/16 Date: 1 /29/16 Date: 02/03/16 Date: 2/3/16 Date: 2/3/2016 Date:

2/3/16 Date: 2.. / Z. 2 j, (o

Exelon Nuclear - Nuclear Fuels P2C21 Core Operating Limits Report COLR PEACH BOTTOM 2 Rev. 10 Page 2of23 Table of Contents Page 1.0 Terms and Definitions 4

2.0 General Information 5

3.0 MAPLHGR Limits 6

4.0 MCPRLimits 7

5.0 Linear Heat Generation Rate Limits 10 6.0 Rod Block Monitor Setpoints 12 7.0 Turbine Bypass Valve Parameters 13 8.0 EOC Recirculation Pump Trip (EOC-RPI) Operability 14 9.0 Stability Protection 15 10.0 Asymmetric Feedwater Temperature Operation (AFTO) 17 11.0 Modes of Operation 21 12.0 Methodology 21 13.0 References 22 Appendix A (Power/Flow Operating Map for MELLLA+)

23

Exelon Nuclear

  • Nuclear Fuels P2C21 Core Operating Limits Report COLR PEACH BOTIOM 2 Rev. 10 Page 3 of 23 List of Tables Table 3-1 MAPLHGR Versus Average Planar Exposure Table 3-2 MAPLHGR Single Loop Operation (SLO) Multiplier Table 4-1 Operating Limit Minimum Critical Power Ratio Table 4-2 Power Dependent MCPR(P) Limit Adjustments and Multipliers Table 4-3 Flow Dependent MCPR Limits MCPR(F)

Table 4-4 SLO Flow Dependent MCPR Limits MCPR(F)

Page 6

6 8

9 9

9 Table 5-1 Linear Heat Generation Rate Limits - U02 rods 10 Table 5-2 Linear Heat Generation Rate Limits - Gad rods 10 Table 5-3 Power Dependent LHGR Multiplier LHGRFAC(P) 11 Table 5-4 Flow Dependent LHGR Multiplier LHGRFAC(F) 11 Table 6-1 Rod Block Monitor Setpoints 12 Table 7-1 Turbine Bypass System Response Time 13 Table 7-2 Minimum Required Bypass Valves to Maintain System Operability 13 Table 8-1 Recirculation Pump Trip Response Time 14 Table 9-1 Automatic BSP Setpoints for the Scram Region 15 Table 9-2 Manual BSP Endpoints for Normal Feedwater Temperature 16 Table 9-3 Manual BSP Endpoints for Reduced Feedwater Temperature 16 Table 10-1 AFTO Thermal Limit Penalties 17 Table 10-2 AFTO Power Dependent LHGR Multiplier LHGRFAC(P) 20F < FWT DELTA~ 55F 18 Table 10-3 AFTO Flow Dependent LHGR Multiplier LHGRFAC(F) 20F < FWT DELTA~ 55F 18 Table 10-4 AFTO Operating Limit Minimum Critical Power Ratio 20F < FWT DELTA~ 55F 19 Table 10-5 AFTO Power Dependent MCPR Limit Adjustments and Multipliers MCPR(P) 20F<FWTDELTA~55F 19 Table 10-6 AFTO Flow Dependent MCPR Limits MCPR(F) 20F < FWT DELTA~ 55F 20 Table 10-7 AFTO MAPLHGR Reduction Factor 20 Table 11-1 Modes of Operation 21 Table 11-2 Additional Equipment Out Of Service Modes of Operation 21

Exelon Nuclear - Nuclear Fuels P2C21 Core Operating Limits Report COLR PEACH BOTIOM 2 Rev. 10 Page4of23 1.0 Terms and Definitions ABSP AFfO AFfOLFWH APRM ARTS BASE BOC DSS-CD DTSP EOC EOOS EOR FFWIR FWHOOS FWT HFCL HTSP ICF ITSP LHGR LHGRFAC(F)

LHGRFAC(P)

LTSP MAPLHGR MCPR MCPR(F)

MCPR(P)

MELLLA MELLLA+

MSIVOOS NCL OLM CPR PLUOOS PROOS RDF RPTOOS RTP RWE SLM CPR SLO TBVOOS TCVffSVOOS Automatic Backup Stability Protection Asymmetric Feedwater Temperature Operation Asymmetric Feedwater Temperature Operation Loss-of-Feedwater Heating Average Power Range Monitor APRM and RBM Technical Specification Analysis Defines two (2) loop operation with at least seven turbine bypass valves in service and the reactor recirculation pump trip system in service.

Beginning Of Cycle Detect and Suppress Solution - Confirmation Density Rod Block Monitor Downscale Trip Setpoint End of Cycle Equipment Out of Service. An analyzed option that assumes certain equipment to be non-operational End of Rated. The cycle exposure at which reactor power is equal to 100% (3951 MWth) with recirculation system flow equal to 100%, all control rods fully withdrawn, all feedwater heating in service and equilibrium Xenon.

Final Feedwater Temperature Reduction Feedwater Heaters Out of Service Feedwater Temperature High How Control Line Rod Block Monitor High Trip Setpoint Increased Core How Rod Block Monitor Intermediate Trip Setpoint Linear Heat Generation Rate ARTS LHGR thermal limit flow dependent adjustments and multipliers ARTS LHGR thermal limit power dependent adjustments and multipliers Rod Block Monitor Low Trip Setpoint Maximum Average Planar Linear Heat Generation Rate Minimum Critical Power Ratio ARTS MCPR thermal limit flow dependent adjustments and multipliers ARTS MCPR thermal limit power dependent adjustments and multipliers Maximum Extended Load Line Limit Analysis Maximum Extended Load Line Limit Analysis Plus Main Steam Isolation Valve Out of Service Natural Circulation Line Operating Limit Minimum Critical Power Ratio Power Load Unbalance Out of Service Pressure Regulator Out of Service Rated Drive How Recirculation Pump Trip Out of Service Rated Thennal Power Rod Withdrawal Error Safety Limit Minimum Critical Power Ratio Single Loop Operation Turbine Bypass Valves Out of Service Turbine Control V alvetrurbine Stop Valve Out of Service

Exelon Nuclear

  • Nuclear Fuels P2C21 Core Operating Limits Report 2.0 General Information COLR PEACH BOTTOM 2 Rev. 10 Page 5 of.23 This report provides the following cycle-specific p~eter limits for Peach Bottom Atomic Power Station Unit 2 CYCLE 21 (RELOAD 20):

Maximum Average Planar Linear Heat Generation Rate (MAPLHGR)

Single Loop Operation (SLO) MAPLHGR multipliers Operating Limit Minimum Critical Power Ratio (OLMCPR)

ARTS MCPR thermal limit adjustments and multipliers Single Loop Operation (SLO) MCPR adjustment Linear Heat Generation Rate (LHGR)

ARTS LHGR thermal limit multipliers Single Loop Operation (SLO) LHGR multipliers Rod Block Monitor (RBM) Analytical Limits, Allowable Values and MCPR Limits Turbine Bypass Valve Parameters BOC Recirculation Pump Trip (EOC-RPT) Parameters Stability Protection Setpoints Asymmetric Feedwater Temperature Operation (AFTO) thennal limit penalties These values have been determined using NRC-approved methodology and are established such that all applicable limits of the plant safety analysis are met. SLO, FWHOOS operation, and FFWTR operation are not permitted in the MELLLA+ Region as controlled by station procedures. For the MELLLA+ Region, a specific definition of FWHOOS is provided in Facility Operating License (FOL) Section 2.C(l6).

This report provides cycle-specific Operating Limit MCPR, LHGR, MAPLHGR thermal limits, and related information for the following conditions:

All points in the operating region of the power/flow map including the MELLLA+ Region down to 83%

of rated core flow during full power (3951 MWt) operation (Appendix A)

Increased Core Flow (ICF), up to 110% of rated core flow End-of-Cycle Power Coastdown to a minimum power level of 40%

Feedwater Heaters Out of Service (FWHOOS) to 55° F temperature reduction Final Feedwater Temperature Reduction (FFWTR) between End-of-Rated (EOR) and End-of-Cycle (EOC) to 90° F temperature reduction (4th and 5th stage FFWTR)

Asymmetric Feedwater Temperature Operation (AFTO)

ARTS provides for power-and flow-dependent thermal limit adjustments and multipliers that allow for a more reliable administration of the MCPR and LHGR thermal limits. The OLMCPR is determined by the cycle-specific reload analyses in Reference 2. Rated LHGR values are obtained from the bundle-specific thermal-mechanical analysis. Supporting documentation for the ARTS-based limits is provided in Reference 2. The Allowable Values documented in Reference 5 for feedwater temperature as a function of thermal power for both FWHOOS and FFWTR are specified in the appropriate Peach Bottom procedures.

Also note that the following description of MAPLHGR, LHGR and MCPR limits pertain to NON - AFTO conditions. A separate description of AFTO limits and their associated ARTS tables are located in Section 10.

Preparation of this report was performed in accordance with Exelon Nuclear procedures. This report is provided to the NRC in accordance with Technical Specification 5.6.5 of Reference 1 and contains all thermal limit parameters related to the implementation of the ARTS hnprovement Program and MELLLA+ for Peach Bottom Unit 2 Cycle 21.

The "BASE" thermal limit values shown in tables are for normal two loop operation with at least the minimum number of turbine bypass valves in service per Section 7.0 and the reactor recirculation pump trip system in service.

Exelon Nuclear* Nuclear Fuels P2C21 Core Operating Limits Report 3.0 MAPLHGR LIMITS 3.1 Technical Specification Section 3.2.1, 3.3.4.2, 3.4.1 and 3.7.6 3.2 Description COLR PEACH BOTTOM 2 Rev. 10 Page 6of23 The MAPLHGR limits (kW/ft) obtained from the emergency core cooling system (ECCS) analysis are provided in Table 3-1. The MAPLHGR limits comprise a given fuel type as a function of average planar exposure. The MAPLHGR tables are used when hand calculations are required. All MAPLHGR values for GNF2 as a function of axial location and average planar exposure shall be less than or equal to the applicable MAPLHGR limits for GNF2 fuel and lattice type. These MAPLHGR limits are specified in Reference 2 and the process computer databank. The SLO MAPLHGR multiplier is provided in Table 3-2 per Reference 2 and must be applied to the Table 3-1 limits when operating in SLO. The impact of AFfO on MAPLHGR is addressed in Section 10.

TABLE3-1 MAPLHGR Versus Average Planar Exposure (Reference 2)

Average Planar Exposure MAPLHGR Limit (GWD/ST)

(kW/ft) 0.0 13.78 17.52 13.78 60.78 7.50 63.50 6.69 TABLE3-2 MAPLHGR Single Loop Operation (SLO) Multiplier (Reference 2)

SLO Multiplier 0.73

Exelon Nuclear

  • Nuclear Fuels P2C21 Core Operating Umits Report 4.0 MCPR LIMITS 4.1 Technical Specification Section 2.1.1.2, 3.2.2, 3.3.4.2, 3.4.1and3.7.6 4.2 Description COLR PEACH BOTTOM 2 Rev. 10 Page 7 of 23 The Operating Limit MCPR (OLMCPR) for GNF2 fuel is provided in Tables 4-1 and 4-2. These values are detennined by the cycle-specific fuel reload analyses in Reference 2. Control rod scram time verification is required as per Technical Specification 3.1.4, "Control Rod Scram Times". Tau, a measure of scram time performance to notch position 36 throughout the cycle, is detennined based on the cumulative scram time test results. The calculation of Tau shall be performed in accordance with site procedures. Linear interpolation shall be used to calculate the OLMCPR value if Tau is between 0.0 (Tau Option B) and 1.0 (Tau Option A).

Separate OLMCPR values are presented in Table 4-1 for the following conditions:

  • TBVs In-Service (per section 7.0), RPT In-Service (per section 8.0), and maximum FFWTR of 90 °P (a.k.a. "BASE")
  • TBVs Out-of-Service (per section 7.0), RPT In-Service (per section 8.0), and maximumFFWTR of90 °P
  • TBV s In-Service (per section 7.0), RPT Out-of-Service (per section 8.0), and maximum FFWTR of 90 °P The ARTS-based power-dependent MCPR limits are provided in Table 4-2. Table 4-2 is valid for a maximum temperature reduction of 90 °P for FFWTR operation (bounding for FWHOOS operation). The flow-dependent MCPR limits are provided in Tables 4-3 and 4-4. Table 4-3 is valid for dual loop operating conditions with symmetric feedwater temperature operation and Table 4-4 is valid for single loop operating conditions with symmetric feedwater temperature operation. The impact of AFTO on MCPR is addressed in Section 10.

Exelon Nuclear *Nuclear Fuels P2C21 Core Operating Limits Report TABLE4*1 COLR PEACH BOTIOM 2 Rev. 10 Page 8of23 Operating Limit Minimum Critical Power Ratio (Reference 2)

SCRAM Cycle EXPosure Time

<EOR-4409

~EOR-4409 EOOS Combination Option<l)

MWd/ST MWd/ST B

1.40 1.40 BASE A

1.41 1.48 B

1.43 1.43 BASESLO A

1.43 1.48 B

1.44 1.44 TBVOOS A

1.44 1.52 B

1.44 1.44 TBVOOSSLO A

1.44 1.52 B

1.40 1.47 RPTOOS A

1.56 1.64 B

1.43 1.47 RPTOOSSLO A

1.56 1.64 (1) When Tau does not equal O or 1, use linear interpolation

Exelon Nuclear

  • Nuclear Fuels P2C21 Core Operating Limits Report TABLE4-2 COLR PEACH BOTTOM 2 Rev. 10 Page 9of23 Power Dependent MCPR(P) Limit Adjustments And Multipliers (Symmetric Feedwater Heating)

(Reference 2)

Core Core Thermal Power ( % of rated)

EOOS Combination Flow(%

0 23

<.26.7

~6.7 40 55 65 85 100 of rated) Operating Limit MCPR Operating Limit MCPR Multiplier, Kp Base Base SLO RPTOOS RPTOOSSLO TBVOOS TBVOOSSLO s6o

>60 s6o

>60 s6o

>60 s6o

>60 s6o

>60 s6o

>60 2.67 2.67 2.60 1.352 1.352 2.99 2.99 2.83 2.67 2.67 2.60 1.352 1.352 2.99 2.99 2.83 2.67 2.67 2.60 1.352 2.99 2.99 2.83 1.352 2.67 2.67 2.60 1.352 1.352 2.99 2.99 2.83 3.64 3.64 3.25 4.15 4.15 3.78 1.659 1.479 3.64 3.64 3.25 1.659 1.479 4.15 4.15 3.78 TABLE4-3 Flow Dependent MCPR Limits MCPR(F)

(Symmetric Feedwater Heating)

(Reference 2)

Core Flow MCPR(F)

(%rated)

Limit 0.0 1.75 30.0 1.57 79.0 1.28 110.0 1.28 TABLE4-4 1.317 1.317 1.317 1.317 1.373 1.373 SLO Flow Dependent MCPR Limits MCPR(F)

(Symmetric Feedwater Heating)

(Reference 2)

Core Flow MCPR(F)

(%rated)

Limit 0.0 1.75 30.0 1.57 79.0 1.28 110.0 1.28 1.131 1.082 1.000 1.131 1.082 1.000 1.131 1.082 1.000 1.131 1.082 1.000 1.155 1.082 1.000 1.155 1.082 1.000

Exelon Nuclear

  • Nuclear Fuels P2C21 Core Operating Limits Report COLR PEACH BOTTOM 2 Rev. 10 Page 10of23 5.0 LINEAR HEAT GENERATION RATE LIMITS 5.1 Technical Specification Section 3.2.3, 3.3.4.2, 3.4.1and3.7.6 5.2 Description The LHGR values for GNF2 fuel type are provided in Tables 5-1 and 5-2. The ARTS-based LHGR power-dependent multipliers are provided in Table 5-3. Table 5-3 is valid for a maximum temperature reduction of 90° F for FFWTR operation (bounding for FWHOOS operation). The flow-dependent multipliers are provided in Table 5-4 as a function of the number of recirculation loops in operation.

The SLO LHGR multiplier is provided and accounted for in Table 5-4. The power-and flow-dependent LHGR multipliers were obtained from Reference 2. The impact of AFTO on LHGR is addressed in Section 10. The power and flow dependent LHGR multipliers are sufficient to provide adequate protection for the off-rated conditions from an ECCS-LOCA analysis perspective.

TABLES-1 Linear Heat Generation Rate Limits - U02 rods (References 4 and 11)

Fuel Type LHGRLimit GNF2 See Appendix B of Reference 4 TABLES-2 Linear Heat Generation Rate Limits - Gad rods (References 4 and 11)

Fuel Type LHGRLimit GNF2 See Appendix B of Reference 4

Exelon Nuclear - Nuclear Fuels P2C21 Core Operating Limits Report TABLE5-3 COLR PEACH BOTTOM 2 Rev. 10 Page 11of23 Power Dependent LHGR Multiplier LHGRFAC(P)

(Symmetric Feedwater Heating)

(Reference 2)

Core Flow Core Thermal Power ( % of rated)

EOOS Combination Base Base SLO RPTOOS RPTOOSSLO TBVOOS TBVOOSSLO EOOS Combination Dual Loop Single Loop

(%of 0

23

<26.7

~6.7 40 55 rated)

LHGRF AC(P) Multiplier

$60 0.508 0.508 0.522 0.748 0.756

>60 0.508 0.508 0.522

$60 0.508 0.508 0.522 0.508 0.748 0.756

>60 0.508 0.522

$60 0.508 0.508 0.522

>60 0.508 0.508 0.522 0.748 0.756

$60 0.508 0.508 0.522 0.748 0.756

>60 0.508 0.522 0.508

$60 0.397 0.397 0.442 0.635 0.655

>60 0.410 0.410 0.417

$60 0.397 0.397 0.442 0.635 0.655

>60 0.410 0.410 0.417 TABLE5-4 Flow Dependent LHGR Multiplier LHGRFAC(F)

(Symmetric Feedwater Heating)

(Reference 2)

Core Flow ( % of rated) 0 30 33.6 70 LHGRF AC(F) Multiplier 0.506 0.706 0.730 0.973 0.506 0.706 0.730 0.730 0.771 0.771 0.771 0.771 0.714 0.714 80 1.000 0.730 65 85 0.817 0.959 0.817 0.959 0.817 0.959 0.817 0.959 0.817 0.930 0.817 0.930 110 1.000 0.730 100 1.000 1.000 1.000 1.000 1.000 1.000

Exelon Nuclear

  • Nuclear Fuels P2C21 Core Operating Limits Report COLR PEACH BOTTOM 2 Rev. 10 Page 12of23 6.0 ROD BLOCK MONITOR SETPOINTS 6.1 Technical Specification Section 3.3.2.1 6.2 Description The RBM power-biased Analytical Limits, Allowable Values and MCPR Limits are provided in Table 6-1 with supporting documentation in References 2 and 9. These values correspond to the OLMCPR values provide in Table 4-1.

Power Level LTSP ITSP HTSP INOP TABLE 6-1 Rod Block Monitor Setpoints (References 2 and 9)

Analytical Lintit<1>

Allowable Value0>

123.0%

121.2%

118.0%

116.2%

113.2%

111.4%

NIA NIA MCPRLimit

< 1.70 <2>

< 1.40 <3>

< 1.70 <2>

< 1.40 <3>

< 1.70 <2>

< 1.40 <3>

< 1.70 <2>

< 1.40 <3>

(1) These setpoints (with RBM filter time constant between 0.1 seconds and 0.55 seconds) are based on a cycle-specific rated RWE MCPR limit which is less than or equal to the minimum cycle OLMCPR based on other events (see COLR References 2 and 9).

(2) This is the MCPR limit (given THERMAL POWER is >28.4% and < 90%) below which the RBM is required to be OPERABLE (see COLR Reference 2 and TS Table 3.3.2.1-1).

(3) This is the MCPR limit (given THERMAL POWER is > 90%) below which the RBM is required to be OPERABLE (see COLR Reference 2 and TS Table 3.3.2.1-1). -

Exelon Nuclear - Nuclear Fuels P2C21 Core Operating Limits Report COLR PEACH BOTTOM 2 Rev. 10 Page 13of23 7.0 TURBINE BYPASS VAL VE PARAMETERS 7.1 Technical Specification Section 3.7.6 7.2 Description The operability requirements for the steam bypass system are governed by Technical Specification 3.7.6.

If the requirements cannot be met, the appropriate power and flow dependent limits for Turbine Bypass Valves Out-of-Service (TBVOOS) must be used. Additionally, the OLMCPR for TBVOOS must be applied. Table 7-1 includes the Turbine Bypass Valve response time parameters. The minimum number of bypass valves to maintain system operability is provided in Table 7-2 per Refer~nce 14.

TABLE7-1 Turbine Bypass System Response Time (Reference 14)

Maximum delay time before start of bypass valve opening following initial turbine inlet valve movement0>

Maximum time after initial turbine inlet valve movement0> for bypass valve position to reach 80% of full flow (includes the above delay time) 0.10 sec 0.30 sec (1)

Fust movement of any TSV QI any TCV QI generation of the turbine bypass valve flow signal (whichever occurs first)

TABLE7*2 Minimum Required Bypass Valves To Maintain System Operability (Reference 14)

Reactor Power No. of Valves in Service P~23%

7

Exelon Nuclear - Nuclear Fuels P2C21 Core Operating Limits Report COLR PEACH BOTTOM 2 Rev.10 Page 14of23 8.0 EOC RECIRCULATION PUMP TRIP (EOC-RPT) OPERABILITY 8.1 Technical Specification Section 3.3.4.2 8.2 Description The operability requirements for the EOC Recirculation Pump Trip are governed by Technical Specification 3.3.4.2. If the requirements cannot be met, the appropriate power and flow dependent limits for EOC Recirculation Pump Trip Out Of Service (RPTOOS) must be used. Additionally, the OLMCPR for RPTOOS must be applied. Table 8-1 includes the total RPT response time parameter.

TABLES-1 Recirculation Pump Trip Response Time (Reference 14)

Total Recirculation Pump Trip Response Time The time from when the turbine valves (turbine control valve or turbine stop valve) start to close until complete arc suppression of the EOC-RPT circuit breakers as described in Reference 7.

0.175 sec

Exelon Nuclear - Nuclear Fuels P2C21 Core Operating Limits Report 9.0 STABILITY PROTECTION 9.1 Technical Specification COLR PEACH BOTTOM 2 Rev. 10 Page 15of23 Section 3.3.1.1, Table 3.3.1.1-1Function2.f, Section 5.6.5 9.2 Description Per Reference 2, the Cycle 21 DSS-CD SAD Setpoint was confmned to be 1.10 for DLO and SLO. The Automatic Backup Stability Protection (BSP) Setpoints are provided in Table 9-1. The Manual BSP Endpoints for Normal Feedwater Temperature and Reduced Feedwater Temperature are provided in Tables 9-2 and Table 9-3.

TABLE9-1 Automatic BSP Setpoints for the Scram Region (Reference 2)

Parameter Symbol Value Slope of ABSP APRM flow-Illrrip 1.65 biased trip linear segment.

ABSP APRM flow-biased trip setpoint power intercept.

Constant Power Line for Trip PasP-Trip 40.5 %RTP from zero Drive Flow to Flow Breakpoint value.

ABSP APRM flow-biased trip setpoint drive flow intercept.

WasP-Trip 46.7 %RDF Constant Flow Line for Trip.

Flow Breakpoint value WasP-Break 25.0 %RDF

Exelon Nuclear *Nuclear Fuels P2C21 Core Operating Limits Report COLR PEACH BOTTOM 2 Rev. 10 Page 16of23 Endpoint Al Bl A2 B2 A3 B3 Endpoint Al Bl A2 B2 TABLE 9.2°>

Manual BSP Endpoints for Normal Feedwater Temperature (Reference 2)

Power(%)

Flow(%)

Definition 77.7 53.6 Scram Region Boundary, HFCL 40.5 31.0 Scram Region Boundary, NCL 64.5 50.0 Controlled Entry Region Boundary, MEL LL A 28.1 30.l Controlled Entry Region Boundary, NCL 100 99.0 BSP Boundary Intercept, MELLLA 60.5 44.9 BSP Boundary Intercept, MELLLA Line TABLE 9.3<o Manual BSP Endpoints for Reduced Feedwater Temperature (Reference 2)

Power(%)

Flow(%)

Definition 67.1 53.4 Scram Region Boundary, MELLLA 35.1 30.7 Scram Region Boundary, NCL 69.3 56.2 Controlled Entry Region Boundary, MELLLA 28.l 30.1 Controlled Entry Region Boundary, NCL Note: The BSP Boundary for Reduced Feedwater Temperature is defined by the MELLLA line, per Reference 2.

(1) Station may elect to place additional administrative margin on the endpoints provided in Table 9-2 and Table 9-3.

Exelon Nuclear - Nuclear Fuels P2C2 l Core Operating Limits Report COLR PEACH BOTTOM 2 Rev. 10 Page 17 of 23 10.0 ASYMMETRIC FEEDWATER TEMPERATURE OPERATION (AFTO)

Asymmetric feedwater heating (resulting from removing a heater string, or individual feedwater heaters, from operation) is the result of the specific configuration of the feedwater lines at Peach Bottom. A reduction in heating in either the 'A' or the 'C' heater strings will result in a temperature mismatch between the feedwater flows entering the opposite sides of the reactor vessel. This temperature mismatch may result in errors in the thermal limit values calculated by the core monitoring system. Thermal limit values for all conditions and events are impacted by these errors excluding SLO conditions. The P2C21 COLR Rev. 9 was the first COLR to no longer require implementation of SLO AFfO penalty files. The station no longer requires SLO AFI'O files or penalties due to a 3D MONICORE upgrade required for EPU operation. Asymmetric feedwater temperature operation (AFI'O) is defined as operation in a feedwater heater/string configuration that results in a specified threshold difference as described in Reference 10.

To simplify the implementation of the AFfO limits, only the maximum AFTO penalties indicated in Table 10-1 will be implemented when the threshold asymmetry temperature (temperature above which a penalty is required) is exceeded. This will minimize the number of AFl'O thermal limit tables in the COLR and core monitoring system.

40F < FWT DELTA~ 55F 30F < FWT DELTA~ 40F 20F < FWT DELTA~ 30F OF< FWT DELTA~ 20F TABLEl0-1 AFTO Thermal Limit Penalties (Asymmetric Feedwater Heating)

(Reference 10)

MFLCPR 3%

2%

2%

No Penalty LHGR LThflTS MFLPD/MAPRAT 4%

3%

2%

No Penalty The ARTS-based LHGR power-dependent multipliers for AFTO operation are provided in Table 10-2. The flow-dependent multipliers for AFTO in DLO are provided in Table 10-3. The power-and flow-dependent LHGR multipliers were obtained from Reference 2 and were adjusted with the appropriate penalties displayed in Table 10-1 as per Reference 10. The maximum feedwater temperature difference allowed without a thermal limit penalty is 20 0F. Once the temperature difference exceeds 20 °F the maximum penalties from Table 10-1 are applied to the thermal limits. Additionally, no LHGR penalties are required for asymmetric feedwater temperature option while in SLO as previously discussed.

Exelon Nuclear

  • Nuclear Fuels P2C21 Core Operating Limits Report COLR PEACH BOTTOM 2 Rev. 10 Page 18of23 TABLE 10-2 AFTO Power Dependent LHGR Multiplier LHGRFAC(P) 20F < FWT DELTA :5 55F (Asymmetric Feedwater Heating)

(References 2 and 10)

Core Thermal Power ( % of rated)

EOOS Combination Core Flow 0

23

<26.7

~6.7 40 55 65 85

(%of rated)

LHGRFAC(P) Multiplier

560 0.488 0.488 0.501 Base 0.718 0.726 0.740 0.784 0.921

>60 0.488 0.488 0.501

560 0.488 0.488 0.501 RPTOOS 0.488 0.488 0.501 0.718 0.726 0.740 0.784 0.921

>60

560 0.381 0.381 0.424 TBVOOS 0.610 0.629 0.685 0.784 0.893

>60 0.394 0.394 0.400 TABLEl0-3 AFTO Flow Dependent LHGR Multiplier LHGRFAC(F) 20F < FWT DELTA :5 55F (Asymmetric Feedwater Heating)

(References 2 and 10)

Core Flow ( % of rated)

EOOS Combination 0

I 30 I 33.60 I 70 I

80 I

110 LHGRFAC(F) Multiplier Dual Loop 0.486 I 0.678 I 0.701 I 0.934 I 0.960 I 0.960 100 0.960 0.960 0.960

Exelon Nuclear

  • Nuclear Fuels P2C21 Core Operating Limits Report MCPRL'1TS COLR PEACH BO'ITOM 2 Rev. 10 Page 19of23 The OLMCPRs during asymmetric feedwater temperature operation with a feedwater temperature difference greater than 20 °P are provided in Table 10-4. The ARTS-based power-dependent MCPR limits for use during AFTO conditions are provided in Table 10-5. The flow-dependent MCPR limits for AFTO are provided in Table 10-6. The power and flow-dependent OLMCPR curves were obtained from Reference 2 and were adjusted with a 3% penalty for feedwater temperature difference greater than 20 °P as displayed in Table 10-1 as per Reference 10. No MCPR penalties are required for asymmetric temperature differentials less than or equal to 20 °F. Additionally, no MCPR penalties are required for asymmetric feedwater temperature option while in SLO as previously discussed.

TABLEl0-4 AFTO Operating Limit Minimum Critical Power Ratio 20F < FWT DELTA :5 55F (Asymmetric Feedwater Heating)

(References 2 and 10)

SCRAM Cycle Exuosure Time

<EOR-4409

~EOR-4409 EOOS Combination Option<l)

MWd/ST MWd/ST B

1.44 1.44 BASE A

1.45 1.52 B

1.48 1.48 TBVOOS A

1.48 1.57 B

1.44 1.51 RPTOOS A

1.61 1.69 TABLE 10-5 AFTO Power Dependent MCPR Limit Adjustments And Multipliers MCPR(P) 20F < FWT DELTA :5 55F (Asymmetric Feedwater Heating)

(References 2 and 10)

Core Core Thermal Power ( % of rated)

EOOS Combination Flow(%

0 23

<26.7

'?:.26.7 40 55 65 85 100 of rated) Operating Limit MCPR Operating Limit MCPR Multiplier, Kp 560 2.75 2.75 2.68 1.352 1.317 1.131 1.000 Base 1.352 1.082

>60 3.08 3.08 2.91 560 2.75 2.75 2.68 1.000 RPTOOS

>60 3.08 2.91 1.352 1.352 1.317 1.131 1.082 3.08 560 3.75 3.75 3.35 1.000 TBVOOS

>60 4.27 3.89 1.659 1.479 1.373 1.155 1.082 4.27 (1) When Tau does not equal O or 1, use linear interpolation.

Exelon Nuclear - Nuclear Fuels P2C21 Core Operating Llmits Report TABLE 10-6 COLR PEACH BOTTOM 2 Rev. 10 Page 20of23 AFTO Flow Dependent MCPR Limits MCPR(F) 20F < FWT DELTA:::; SSF (BOC to EOC)(Asymmetric Feedwater Heating)

(References 2 and 10)

Flow MCPR(F)

(%rated)

Limit 0.0 1.80 30.0 1.62 79.0 1.32 110.0 1.32 MAPLHGR LIMITS An appropriate penalty must be applied to MAPLHGR limits under asymmetric feedwater temperature operation (AFfO) for varying temperature differentials as displayed in Table 10-1 as per Reference 10. No MAPLHGR penalties are required for asymmetric feedwater temperature option while in SLO as previously discussed.

TABLEl0-7 AFTO MAPLHGR Reduction Factor (Asymmetric Feedwater Heating)

(References 2 and 10)

AFTO Reduction Factor 20F < FWT DELTA:::: 55F I 0.960

Exelon Nuclear

  • Nuclear Fuels P2C2 l Core Operating Limits Report 11.0 MODES OF OPERATION TABLE 11*1 Modes of Operation (Reference 2)

EOOS Options1 Base, Option A or B Base SLO, Option A or B TBVOOS, Option A or B TBVOOS SLO, Option A or B RPTOOS, Option A or B RPTOOS SLO, Option A or B TBVOOS and RPTOOS, Option A or B TBVOOS and RPTOOS SLO, Option A or B TABLE 11-2 COLR PEACH BOTI'OM 2 Rev. 10 Page 21of23 Supported Operating Reldon2 Yes Yes3 Yes Yesj Yes Yes3 No No Additional Equipment Out Of Service Modes of Operation EOOS PLUOOS (controlled via station procedures)

PROOS (controlled via station procedures)

TCVfTSVOOS (controlled via station procedures)

MSNOOS (controlled via station procedures)

AFfO LFWH (controlled via station procedures) 12.0 MEmODOLOGY The analytical methods used in determining the core operating limits have been previously reviewed and approved by the NRC, specifically those described in the following document:

1. "General Electric Standard Application for Reactor Fuel", NEDE-24011-P-A-22, November 2015 and U.S.

Supplement NEDE-24011-P-A-22-US, November 2015.

1 Modes of operation with thermal limit sets in the COLR

'Operating Region refers to. operation on the Power to Flow map with or without FFWTR or AFTO.

Operation not permitted in the MELLLA+ Region for Reduced Feedwater Temperature conditions as controlled by station procedures.

' Operation in SLO not permitted in the MELLLA+ Region as controlled by station procedures.

Exelon Nuclear - Nuclear Fuels P2C21 Core Operating Limits Report

13.0 REFERENCES

COLR PEACH BOTIOM 2 Rev. 10 Page 22of23

1. "Technical Specifications for Peach Bottom Atomic Power Station Unit 2", Docket No. 50-277, Appendix A to License No. DPR-44.
2. Global Nuclear Fuel Document "Supplemental Reload Licensing Report for Peach Bottom Unit 2, Reload 20, Cycle 21 Extended Power Uprate (EPU)/Maximum Extended Load Line Limit Analysis Plus (MELLLA+)",

GNF Document No. 001N2150-SRLR, Revision 1, January 2015.

3. Global Nuclear Fuel Document "General Electric Standard Application for Reactor Fuel", NEDE-24011-P-A-22, November 2015 and U.S. Supplement NEDE-24011-P-A-22-US, November 2015.
4. Global Nuclear Fuel Document NEDC-33270P Rev. 5, "GNF2 Advantage Generic Compliance with NEDE-24011-P-A (GESTAR II)," May 2013.
5. General Electric Hitachi Document 001N2494-RO, "Peach Bottom EPU Evaluation of Feedwater Temperature vs. Reactor Power for Feedwater Temperature Conditions of Nominal Rated, FWHOOS (Nominal -55°F) and FFWTR (Nominal -90°F)", July 2014. This document is searchable in Exelon EDMS under document number "PEAM-EPU-1 Rev. OA."
6. General Electric Hitachi Document NED0-33720, "Safety Analysis Report for Peach Bottom Atomic Power Station Units 2 & 3 Maximum Extended Load Line Limit Analysis Plus", Revision 0, September 2014.
7. PECO Calculation PE-0173, "Determination of Total Time Required to Initiate the Trip Signal to the EOC-RPT Circuit Breakers Trip Coils and to Complete the Recirculation Pump Trip", Rev. 1dated12/22/98.
8. General Electric Hitachi Document GEH-0000-0107-7348, "GNF2 Fuel Design Cycle-Independent Analyses For Exelon Peach Bottom Atomic Power Station Units 2 and 3", Revision 6, April 2015. This document is searchable in Exelon EDMS under document number "G-080-VC-399 Rev. 3."
9. PECO Calculation PE-0251, Revision 02B, "PRNMS Setpoint Calculation" dated 5/26/15.
10. General Electric Hitachi Document 001N6733-Rl, "Final Evaluation Report Exelon Nuclear Generating Company LLC, Peach Bottom Units 2 & 3, MELLLA+, Asymmetric Feedwater Temperature Operation for EPU/MELLLA+", Revision 1, September 2014. This document is searchable in Exelon EDMS under document number "PEAM-EPU-68 Rev. 1."
11. Global Nuclear Fuel Document 001N6160.1-FBIR, "Fuel Bundle Information Report for Peach Bottom Unit 2 Reload 20 Cycle 21 Extended Power Uprate (EPU)/Maximum Extended Load Line Limit Analysis Plus (MELLLA+) and Extended Power Uprate (EPU)/Maximum Extended Load Line Limit Analysis (MELLLA)",

Revision 1, July 2014.

12. Not Used
13. Not Used
14. Exelon TODI ENSAF ID# ES1400004, Rev. 1, "Final Resolved OPL-3 Parameters for Peach Bottom Unit 2 Cycle 21 -EPU/MELLLA+", May 9, 2014.

Exelon Nuclear

  • Nuclear Fuels COLR PEACH BOTTOM 2 Rev. 10 P2C21 Core Operating Limits Report Page 23of23 APPENDIX A Power/Flow Operating Map for MELLLA+

(Reference 6)

Core Flow ~Db/hr) 0 10 20 30 40 so 60 70 80 90 100 110 120 120 4741 lOO'IW O.TP

]=3951 MWt PL 100% core Flow 110 I

I 4346 ITJITJ CD 100 3951 90 F

110.0 100.0 3556 G

110.0 21.3 H

100.0 21.3 80 I

37.4 21.3 3161 J

83.0 100.0 K

55.0 78.8

'?ft.

70 L

55.0 68.4 2766 I

I t

~

~ 60 Qfil-2370 ::;

c:

j_

I l

I I

I

~

50 I

1975,.*

1--J i

  • ----*-r-40 1580 I

30

-- r--1 i

1185 i

20 I

lca~lilUon tlterlock r*

  • ~ --~*~ [)) [I]

790 I

I I

10 J.....

j 1

~

395

  • -** r-
  • --"i'.

i i

I '

I 0

0 0

10 20 30 40 50 60 70 80 90 100 110 120 Core Flow {°lo)

ATTACHMENT Unit 3 Core Operating Limits Report for Reload 20, Cycle 21, Revision 9

Exelon Nucleati-Nilcle*r fuels P.3C21 Core Operating Limlti Report COLR PJ!d\\<;:H 1J01'TOM 3 Rev. 9 Page 1 of26 CORE OPERATING LIMITS REPORT FOR PEACH B(>-TTOM ATOl\\'IIC POWER STATION UNIT 3 RELOAD 20, CYCLE 21 (This-is a Complete Re-write).

~

Prepared.By: ___________

Date:

4/1/2016, P.Hemy R<viowedBy: ~

  • ~glnetring u.*------

ReviewedBy:~-----/2.5~-----

Oate; 4/1/20~6.

Engineering Safe~ Analysis Independent i1

'11.1. JI ReviewBy: _____

'.;;_:,..u.,.._' _

1'_~*----

Date:

4/1/2016 B. Miller (L

~ --

ApprovedBy: __ -F-.;.;-

'Jl_~

J.J. Tusar Date: 4/5/2016 Station Qualified

/) Jj

~

ftiµiL;*

Date: _L-f_Y -r'_/i_J 6

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating Limits Report Table of Contents 1.0 Tenns and Definitions 2.0 General Information 3.0 MAPLHGR Limits 4.0 MCPR Limits 5.0 Linear Heat Generation Rate Limits 6.0 Rod Block Monitor Setpoints 7.0 Turbine Bypass Valve Parameters 8.0 EOC Recirculation Pump Trip (EOC-RPT) Operability 9.0 Stability Protection COLR PEACH BOTTOM 3 Rev. 9 Page 2of26 Page 5

6 7

8 12 14 15 16 17 10.0 Asymmetric Feedwater Temperature Operation (AFTO) 19 11.0 Modes of Operation 24 12.0 Methodology 24 13.0 References 25 Appendix A (Power/Flow Operating Map for MELLLA+)

26

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating limits Report Revision Revision 9 Revision History COLR PEACH BOITOM 3 Rev. 9 Page 3of26 Description Revised COLR for MELLLA+

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating Limits Report COLR PEACH BOTIOM 3 Rev. 9 Page4of26 List of Tables Table 3-1 MAPLHGR Versus Average Planar Exposure Table 3-2 MAPLHGR Single Loop Operation (SLO) Multiplier Table 4-1 Operating Limit Minimum Critical Power Ratio Table 4-2 Power Dependent MCPR(P) Limit Adjustments and Multipliers Table 4-3 Flow Dependent MCPR Limits MCPR(F)

Table 4-4 SLO Flow Dependent MCPR Limits MCPR(F)

Table 5-1 Linear Heat Generation Rate Limits - U02 rods Table 5-2 Linear Heat Generation Rate Limits - Gad rods Table 5-3 Power Dependent LHGR Multiplier LHGRFAC(P)

Table 5-4 Flow Dependent LHGR Multiplier LHGRFAC(F)

Table 6-1 Rod Block Monitor Setpoints Table 7-1 Turbine Bypass System Response Time Table 7-2 Minimum Required Bypass Valves to Maintain System Operability Table 8-1 Recirculation Pump Trip Response Time Table 9-1 Automatic BSP Setpoints for the Scram Region Table 9-2 Manual BSP Endpoints for Normal Feedwater Temperature Table 9-3 Manual BSP Endpoints for Reduced Feedwater Temperature Page 7

7 9

10 11 11 12 12 13 13 14 15 15 16 17 18 18 Table 10-1 AFTO Thermal Limit Penalties 19 Table 10-2 AFTO Power Dependent LHGR Multiplier LHGRFAC(P) 20F < FWT DELTA$ 55F 20 Table 10-3 AFTO Flow Dependent LHGR Multiplier LHGRFAC(F) 20F < FWT DELTA$ 55F 20 Table 10-4 AFTO Operating Limit Minimum Critical Power Ratio 20F < FWT DEL TA$ 55F 21 Table 10-5 AFTO Power Dependent MCPR Limit Adjustments and Multipliers 22 MCPR(P) 20F < FWT DELTA$ 55F Table 10-6 AFTO Flow Dependent MCPR Limits MCPR(F) 20F < FWT DELTA$ 55F 22 Table 10-7 AFTO MAPLHGR Reduction Factor 23 Table 11-1 Modes of Operation 24 Table 11-2 Additional Equipment Out of Service Modes of Operation 24

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating Limits Report 1.0 Terms and Definitions COLR PEACH BOTTOM 3 Rev. 9 Page 5of26 ABSP Automatic Backup Stability Protection AFfO AFfOLFWH APRM ARTS BASE BOC BSP DSS-CD DTSP EOC EOOS EOR FFWI'R FWHOOS FWf HFCL HTSP ICF ITSP LHGR LHGRFAC(F)

LHGRFAC(P)

LTSP MAPLHGR MCPR MCPR(F)

MCPR(P)

MELLLA MELLLA+

MSIVOOS NCL OLM CPR PLUOOS PROOS RDF RPTOOS RTP RWE SLM CPR SLO TB SOOS TCV/l'SVOOS Asymmetric Feedwater Temperature Operation Asymmetric Feedwater Temperature Operation Loss-of-Feedwater Heating Average Power Range Monitor APRM and RBM Technical Specification Analysis Defines two (2) loop operation with at least seven turbine bypass valves in service and the reactor recirculation pump trip system in service.

Beginning Of Cycle Backup Stability Protection Detect and Suppress Solution - Confinnation Density Rod Block Monitor Downscale Trip Setpoint End of Cycle Equipment Out of Service. An analyzed option that assumes certain equipment to be non-operational End of Rated. The cycle exposure at which reactor power is equal to 100% (3951 MW th) with recirculation system flow equal to 100%, all control rods fully withdrawn, all feedwater heating in service and equilibrium Xenon.

Final Feedwater Temperature Reduction Feedwater Heaters Out of Service Feedwater Temperature High Flow Control Line Rod Block Monitor High Trip Setpoint Increased Core Flow Rod Block Monitor Intermediate Trip Setpoint Linear Heat Generation Rate ARTS LHGR thermal limit flow dependent adjustments and multipliers ARTS LHGR thermal limit power dependent adjustments and multipliers Rod Block Monitor Low Trip Setpoint Maximum Average Planar Linear Heat Generation Rate Minimum Critical Power Ratio ARTS MCPR thermal limit flow dependent adjustments and multipliers ARTS MCPR thermal limit power dependent adjustments and multipliers Maximum Extended Load Line Limit Analysis Maximum Extended Load Line Limit Analysis Plus Main Steam Isolation Valve Out of Service Natural Circulation Line Operating Limit Minimum Critical Power Ratio Power Load Unbalance Out of Service Pressure Regulator Out of Service Rated Drive Flow Recirculation Pump Trip Out of Service Rated Thermal Power Rod Withdrawal Error Safety Limit Minimum Critical Power Ratio Single Loop Operation Turbine Bypass Valves Out of Service Turbine Control Valve/Turbine Stop Valve Out of Service

Exelon Nuclear - Nuclear Fuels P3C21 Core Operating Umits Report 2.0 General Information COLR PEACH BOTTOM 3 Rev. 9 Page 6of26 This report provides the following cycle-specific parameter limits for Peach Bottom Atomic Power Station Unit 3 CYCIE 21 (RELOAD 20):

Maximum Average Planar Linear Heat Generation Rate (MAPLHGR)

Single Loop Operation (SLO) MAPI.RGR multipliers Operating Limit Minimum Critical Power Ratio (OLMCPR)

ARTS MCPR thennal limit adjustments and multipliers Single Loop Operation (SLO) MCPR adjustment Linear Heat Generation Rate (LHGR)

ARTS LHGR thennal limit multipliers Single Loop Operation (SLO) l.RGR multipliers Rod Block Monitor (RBM) Analytical Limits, Allowable Values and MCPR Limits Turbine Bypass Valve Parameters EOC Recirculation Pump Trip (EOC-RPT) Parameters Stability Protection Setpoints Asymmetric Feedwater Temperature Operation (AFTO) thennal limit penalties These values have been determined using NRC-approved methodology and are established such that all applicable limits of the plant safety analysis are met. SLO, FWHOOS operation, and FFWTR operation are not permitted in the MELLLA+ Region as controlled by station procedures. For the MELLLA+ Region, a specific definition ofFWHOOS is provided in Facility Operating License (FOL) Section 2.C(l6).

This report provides cycle-specific Operating Limit MCPR, LHGR, MAPI.RGR thermal limits, and related information for the following conditions:

All points in the operating region of the power/flow map including MEULA+ Region down to 83%

of rated core flow during full power (3951 MWt) operation (Appendix A)

Increased Core Flow (ICF), up to 110% of rated core flow End-of-Cycle Power Coastdown to a minimum power level of 40%

Feedwater Heaters Out of Service (FWHOOS) to 55° F temperature reduction Fmal Feedwater Temperature Reduction (FFWTR) between End-of-Rated (EOR) and End-of-Cycle (EOC) to 90° F temperature reduction (4th and 5th stage FWHOOS)

Asymmetric Feedwater Temperature Operation (AFTO)

ARTS provides for power and flow-dependent thermal limit adjustments and multipliers that allow for a more reliable administration of the MCPR and l.RGR thermal limits. The OLMCPR is determined by the cycle-specific reload analyses in Reference 2. Rated LHGR values are obtained from the bundle-specific thermal-mechanical analysis. Supporting documentation for the ARTS-based limits is provided in Reference 2. The Allowable Values documented in Reference 5 for feedwater temperature as a function of thermal power for both FWHOOS and FFWTR are specified in the appropriate Peach Bottom procedures.

Also note that the following description of MAPI.RGR, LHGR and MCPR limits pertain to NON - AFTO conditions. A separate description of AFTO limits and their associated ARTS tables are located in Section 10.

Preparation of this report was perfonned in accordance with Exelon Nuclear procedures. This report is provided to the NRC in accordance with Technical Specification 5.6.5 of Reference 1 and contains all thermal limit parameters related to the implementation of the ARTS Improvement Program and MELLLA+ for Peach Bottom Unit 3 Cycle 21.

The "BASE" thennal limit values shown in tables are for nonnal two loop operation with at least the minimum number of turbine bypass valves in service per Section 7.0, the reactor recirculation pump trip system in service, the power load unbalance device in service, and both pressure regulators in service.

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating Limits Report 3.0 MAPLHGR LIMITS 3.1 Technical Specification Section 3.2.1, 3.3.4.2, 3.4.1 and 3.7.6 3.2 Description COLR PEACH BOTTOM 3 Rev. 9 Page 7 of26 The MAPLHGR limits (kW/ft) obtained from the emergency core cooling system (ECCS) analysis are provided in Table 3-1. The MAPLHGR limits comprise a given fuel type as a function of average planar exposure. The MAPLHGR tables are used when hand calculations are required. All MAPLHGR values for GNF2 as a function of axial location and average planar exposure shall be less than or equal to the applicable MAPLHGR limits for GNF2 fuel and lattice type. These MAPLHGR limits are specified in Reference 2 and the process computer databank. The SLO MAPLHGR multiplier is provided in Table 3-2 per Reference 2 and must be applied to the Table 3-1 limits when operating in SLO. The impact of AFTO on MAPLHGR is addressed in Section 10.

TABLE3-1 MAPLHGR Versus Average Planar Exposure (Reference 2)

Average Planar Exposure MAPLHGR Limit (GWD/ST)

(kW/ft) 0.0 13.78 17.52 13.78 60.78 7.50 63.50 6.69 TABLE3-2 MAPLHGR Single Loop Operation (SLO) Multiplier (Reference 2)

SLO Multiplier 0.73

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating Limits Report 4.0 MCPR LIMITS

. 4.1 Technical Specification Section 2.1.1.2, 3.2.2, 3.3.4.2, 3.4.1and3.7.6 4.2 Description COLR PEACH BOTTOM 3 Rev. 9 Page 8of26 The Operating Limit MCPR (OLMCPR) for GNF2 fuel is provided in Tables 4-1and4-2. These values are determined by the cycle-specific fuel reload analyses in Reference 2. Control rod scram time verification is required as per Technical Specification 3.1.4, "Control Rod Scram Times". Tau, a measure of scram time performance to notch position 36 throughout the cycle, is determined based on the cumulative scram time test results. The calculation of Tau shall be performed in accordance with site procedures. Linear interpolation shall be used to calculate the OLMCPR value if Tau is between 0.0 (Tau Option B) and 1.0 (Tau Option A).

Separate OLMCPR values are presented in Table 4-1 for the following conditions:

  • TBS In-Service (per section 7.0), RPT In-Service (per section 8.0), PLU/PR In-Service, and maximum FFWTR of 90 °F (a.k.a. "BASE")
  • TBS Out-of-Service (per section 7.0), RPT In-Service (per section 8.0), PLU/PR In-Service, and maximum FFWTR of 90 °F
  • TBS In-Service (per section 7.0), RPT In-Service (per section 8.0), PLU/PR Out-of-Service, and maximum FFWTR of 90°F
  • TBS In-Service (per section 7.0), RPT Out-of-Service (per section 8.0), PLU/PR In-Service, and maximum FFWTR of 90 °F The ARTS-based power-dependent MCPR limits are provided in Table 4-2. Table 4-2 is valid for a maximum temperature reduction of 90 °F for FFWTR operation (bounding for FWHOOS operation). The flow-dependent MCPR limits are provided in Tables 4-3 and 4-4. Table 4-3 is valid for dual loop operating conditions with symmetric feedwater temperature operation and Table 4-4 is valid for single loop operating conditions with symmetric feedwater temperature operation. The impact of AFTO on MCPR is addressed in Section 10. For PR/PLUOOS +

TBSOOS and PR/PLUOOS + RPTOOS conditions, the limits are listed in Section 10, these values are bounding for non-AFTO conditions.

Exelon Nuclear - Nuclear Fuels P3C21 Core Operating limits Report TABLE4-1 COLR PEACH BOTI'OM 3 Rev. 9 Page 9of26 Operating Limit Minimum Critical Power Ratio (Reference 2)

SCRAM Cycle Exuosure Time

<EOR-2523

~EOR-2523 EOOS Combination Option(l>

MWd/ST MWd/ST B

1.38 1.41 BASE A

1.45 1.49 B

1.43 1.43 BASESL0<2>

A 1.45 1.49 B

1.42 1.46 RPTOOS A

1.59 1.63 B

1.43 1.46 RPTOOS SL0<2>

A 1.59 1.63 B

1.38 1.41 PR/PLUOOS A

1.45 1.49 B

1.43 1.43 PR/PLUOOS SL0<2>

A 1.45 1.49 B

1.42 1.43 TB SOOS A

1.49 1.52 B

1.43 1.43 TBSOOS SLO <2>

A 1.49 1.52 (1) When Tau does not equal O or 1, use linear interpolation.

(2) For single-loop operation, the MCPR operating limit is the same as the analyzed limiting two loop value. However a minimum value of 1.43 is required to obtain an OLMCPR limit set by the Single Loop Operation Recirculation Pump Seizure Event (Reference 2).

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating limits Report TABLE4-2 COLR PEACH BO'ITOM 3 Rev. 9 Page 10of26 Power Dependent MCPR(P) Limit Adjustments and Multipliers (Symmetric Feedwater Heating)

(Reference 2)

Core Core Thermal Power ( % of rated)

Flow 0

23

<26.7

?.26.7 40 55 65 85 100 EOOS Combination

(% oi:

rated Operating Limit MCPR Operating Limit MCPR Multiplier, Kp

)

_s60 2.67 2.67 Base

>60 2.99 2.99 2.60 2.83 1.352 1.352 1.317 1.131 1.082 1.000

_s60 2.67 2.67 2.60 1.352 1.317 1.131 1.082 1.000 BaseSLO

>60 2.99 2.99 1.352 2.83 RPTOOS

_s60 2.67 2.67 2.60 1.352 1.352 1.317 1.131 1.082 1.000

>60 2.99 2.99 2.83 RPTOOSSLO

_s60 2.67 2.67 2.60 1.352 1.352 1.317 1.131 1.082 1.000

>60 2.99 2.99 2.83 PR/PLUOOS

_s60 2.67 2.67 2.60 1.392 1.352 1.317 1.210 1.147 1.000

>60 2.99 2.99 2.83 PR/PLUOOSSLO

_s60 2.67 2.67 2.60 1.392 1.317 1.210 1.147 1.000

>60. 2.99 2.99 1.352 2.83

_s60 3.64 3.64 3.25 TB SOOS

>60 4.15 4.15 1.659 1.479 1.373 1.155 1.082 1.000 3.78

_s60 3.64 3.64 3.25 TBSOOSSLO 1.659 1.479 1.373 1.155 1.082 1.000

>60 4.15 4.15 3.78

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating Limits Report TABLE4-3 COLR PEACH BOTIOM 3 Rev. 9 Page 11of26 Flow Dependent MCPR Limits MCPR(F)

(Symmetric Feedwater Heating)

(Reference 2)

Core Flow MCPR(F)

(%rated)

Limit 0.0 1.75 30.0 1.57 79.0 1.28 110.0 1.28 TABLE4-4 SLO Flow Dependent MCPR Limits MCPR(F)

(Symmetric Feedwater Heating)

(Reference 2)

Core Flow MCPR(F)

(%rated)

Limit 0.0 1.75 30.0 1.57 79.0 1.28 110.0 1.28

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating limits Report COLR PEACH BOTTOM 3 Rev. 9 Page 12of26 5.0 LINEAR HEAT GENERATION RATE LIMITS 5.1 Technical Specification Section 3.2.3, 3.3.4.2, 3.4.1and3.7.6 5.2 Description The LHGR values for GNF2 fuel type are provided in Tables 5-1and5-2. The ARTS-based LHGR power-dependent multipliers are provided in Table 5-3. Table 5-3 is valid for a maximum temperature reduction of 90° F for FFWTR operation (bounding for FWHOOS operation). The flow-dependent multipliers are provided in Table 5-4 as a function of the number of recirculation loops in operation. The SLO LHGR multiplier is provided and accounted for in Table 5-4. The power-and flow-dependent LHGR multipliers were obtained from Reference 2. The impact of AFTO on LHGR is addressed in Section 10. For PR/PLUOOS.+ TBSOOS and PR/PLUOOS + RPTOOS conditions, the limits are listed in Section 10, these values are bounding for non-AFTO conditions. The power and flow dependent LHGR multipliers are sufficient to provide adequate protection for the off-rated conditions from an ECCS-LOCA analysis perspective.

TABLES-1 Linear Heat Generation Rate Limits - U02 rods (References 4 and 11)

Fuel Type LHGRLimit GNF2 See Appendix B of Reference 4 TABLES-2 Linear Heat Generation Rate Limits - Gad rods (References 4 and 11)

Fuel Type LHGRLimit GNF2 See Appendix B of Reference 4

Exelon Nuclear

  • Nuclear Fuels P3C2 l Core Operating Limits Report COLR PEACH BOTTOM 3 Rev. 9 Page 13of26 EOOS Combination Base BaseSLO RPTOOS RPTOOSSLO PR/PLUOOS PR/PLUOOSSLO TB SOOS TBSOOSSLO TABLE5-3 Power Dependent LHGR Multiplier LHGRFAC(P)

(Symmetric Feedwater Heating)

(Reference 2)

Core Thermal Power ( % of rated)

Core Flow 0

23

<.26.7

~6.7 40 55

(%of rated)

LHGRFAC(P) Multiplier

60 0.508 0.508 0.522 0.748 0.756

>60 0.508 0.508 0.522

60 0.508 0.508 0.522 0.748 0.756

>60 0.508 0.508 0.522

60 0.508 0.508 0.522

>60 0.508 0.508 0.748 0.756 0.522

60 0.508 0.508 0.522

>60 0.748 0.756 0.508 0.508 0.522

60 0.508 0.508 0.522

>60 0.508 0.508 0.522 0.620 0.696

60 0.508 0.508 0.522

>60 0.508 0.508 0.522 0.620 0.696

60 0.397 0.397 0.442

>60 0.397 0.397 0.417 0.635 0.655

60 0.397 0.397 0.442 0.635 0.655

>60 0.397 0.397 0.417 TABLE5-4 Flow Dependent LHGR Multiplier LHGRFAC(F)

(Symmetric Feedwater Heating)

(Reference 2)

Core Flow ( % of rated) 0.771 0.771 0.771 0.771 0.751 0.751 0.714 0.714 EOOS Combination 0

30 33.6 70 80 LHGRFAC(F) Multiplier Dual Loop 0.506 0.706 0.730 0.973 1.000 Single Loop 0.506 0.706 0.730 0.730 0.730 65 85 0.817 0.959 0.817 0.959 0.817 0.959 0.817 0.959 0.817 0.959 0.817 0.959 0.817 0.930 0.817 0.930 110 1.000 0.730 100 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating Umits Report 6.0 ROD BLOCK MONITOR SETPOINTS 6.1 Technical Specification Section 3.3.2.1 6.2 Description COLR PEACH BOTTOM 3 Rev. 9 Page 14 of 26 The RBM power-biased Analytical Limits, Allowable Values and MCPR Limits are provided in Table 6-1 with supporting documentation in References 2 and 9. The values correspond to the OLMCPR values provide in Table 4-1.

Power Level LTSP ITSP HTSP INOP TABLE6-1 Rod Block Monitor Setpoints (References 2 and 9)

Analytical Limit(l>

Allowable Value<1>

120.0%

118.2%

115.2%

113.4%

110.2%

108.4%

NIA NIA MCPRLimit

< 1.70 <2>

< 1.40 <3>

< 1.70 (2)

< 1.40 <3>

< 1.70 (2)

< 1.40 <3>

< 1.70 (2)

< 1.40 l3>

(1) These setpoints (with RBM filter time constant between 0.1 seconds and 0.55 seconds) are based on a cycle-specific rated RWE MCPR limit which is less than or equal to the minimum cycle OLMCPR based on other events (see COLR References 2 and 9).

(2) This is the MCPR limit (given THERMAL POWER is >28.4% and < 90%) below which the RBM is required to be OPERABLE (see COLR Reference 2 and TS Table 3.3.2.1-1).

(3) This is the MCPR limit (given THERMAL POWER is > 90%) below which the RBM is required to be OPERABLE (see COLR Reference 2 and TS Table 3

. 3~2.1-1).

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating Limits Report 7.0 TURBINE BYPASS VAL VE PARAMETERS 7.1 Technical Specification Section 3.7.6 7.2 Description COLR PEACH BOTTOM 3 Rev. 9 Page 15of26 The operability requirements for the steam bypass system are governed by Technical Specification 3.7.6. If the requirements cannot be met, the appropriate power and flow dependent limits for Turbine Bypass System Out-of-Service (TBSOOS) must be used. Additionally, the OLMCPR forTBSOOS must be applied. Table 7-1 includes the Turbine Bypass Valve response time parameters. The minimum number of bypass valves to maintain system operability is provided in Table 7-2 per Reference 14.

TABLE7-1 Turbine Bypass System Response Time (Reference 14)

Maximum delay time before start of bypass valve opening following initial turbine inlet valve movement0>

Maximum time after initial turbine inlet valve movement0> for bypass valve position to reach 80% of full flow (includes the above delay time) 0.10 sec 0.30 sec (1)

Fust movement of any TSV.Q! any TCV ID: generation of the turbine bypass valve flow signal (whichever occurs first)

TABLE7-2 Minimum Required Bypass Valves To Maintain System Operability (Reference 14)

Reactor Power No. of Valves in Service P~23%

7

Exelon Nuclear *Nuclear Fuels P3C21 Core Operating limits Report COLR PEACH BOTTOM 3 Rev. 9 Page 16 of 26 8.0 EOC RECffiCULATION PUMP TRIP (EOC-RPT) OPERABILITY 8.1 Technical Specification Section 3.3.4.2 8.2 Description The operability requirements for the EOC Recirculation Pump Trip are governed by Technical Specification 3.3.4.2. If the requirements cannot be met, the appropriate power and flow dependent limits for EOC Recirculation Pump Trip Out Of Service (RPTOOS) must be used.

Additionally, the OLMCPR for RPTOOS must be applied. Table 8-1 includes the total RPT response time parameter.

TABLES-1 Recirculation Pump Trip Response Time (Reference 14)

Total Recirculation Pump Trip Response Time The time from when the turbine valves (turbine control valve or turbine stop valve) start to close until complete arc suppression of the EOC-RPT circuit breakers as described in Reference 7.

0.175 sec

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating Limits Report 9.0 STABILITY PROTECTION 9.1 Technical Specification Section 3.3.1.1, Table 3.3.1.1-1Function2.f, Section 5.6.5 9.2 Description COLR PEACH BOTTOM 3 Rev. 9 Page 17of26 Per Reference 2, the Cycle 21 DSS-CD SAD Setpoint was confirmed to be 1.10 for DLO and SLO.

The Automatic Backup Stability Protection (BSP) Setpoints are provided in Table 9-1. The Manual BSP Endpoints for Normal Feedwater Temperature and Reduced Feedwater Temperature are provided in Tables 9-2 and Table 9-3.

TABLE9-1 Automatic BSP Setpoints for the Scram Region (Reference 2)

Parameter Symbol Value Slope of ABSP APRM flow-mTrip 1.39 biased trip linear segment.

ABSP APRM flow-biased trip setpoint power intercept.

Constant Power Line for Trip PBsP-Trip 39.9 %RTP from zero Drive Flow to Flow Breakpoint value.

ABSP APRM flow-biased trip setpoint drive flow intercept.

WBSP-Trip 46.5 %RDF Constant Flow Line for Trip.

Flow Breakpoint value WBsP-Break 20.0%RDF

Exelon Nuclear *Nuclear Fuels P3C21 Core Operating Limits Report COLR PEACH BOTTOM 3 Rev. 9 Page 18of26 Endpoint Al Bl A2 B2 TABLE 9.2<1>

Manual BSP Endpoints for Normal Feedwater Temperature (Reference 2)

Power(%)

Flow(%)

Definition 76.7 52.2 Scram Region Boundary, MELLLA+

Extension 39.9 31.0 Scram Region Boundary, NCL 64.5 50.0 Controlled Entry Region Boundary, HFCL 28.l 30.l Controlled Entry Region Boundary, NCL Note: The BSP Boundary for Nonna! and Reduced Feedwater Temperature is defined by the MELLLA boundary line, per Reference 2.

TABLE 9.3<1>

Manual BSP Endpoints for Reduced Feedwater Temperature (Reference 2)

Endpoint Power(%)

Flow(%)

Definition Al 65.7 51.5 Scram Region Boundary, HFCL Bl 34.9 30.7 Scram Region Boundary, NCL A2 67.3 53.5 Controlled Entry Region Boundary, HFCL B2 28.1 30.1 Controlled Entry Region Boundary, NCL Note: The BSP Boundary for Normal and Reduced Feedwater Temperature is defined by the MELLLA boundary line, per Reference 2.

(1) Station may elect to place additional administrative margin on the endpoints provided in Table 9-2 and Table 9-3.

Exelon Nuclear *Nuclear Fuels P3C21 Core Operating Limits Report COLR PEACH BOTTOM 3 Rev. 9 Page 19 of 26 10.0 ASYMMETRIC FEEDWATER TEMPERATURE OPERATION (AFTO)

Asymmetric feedwater heating (resulting from removing a heater string, or individual feedwater heaters, from operation) is the result of the specific configuration of the feedwater lines at Peach Bottom. A reduction in heating in either the 'A' or the 'C' heater strings will result in a temperature mismatch between the feedwater flows entering the opposite sides of the reactor vessel. This temperature mismatch may result in errors in the thermal limit values calculated by the core monitoring system. Thermal limit values for all conditions and events are impacted by these errors excluding SLO conditions. The P3C21 COLR Rev. 8 was the first COLR to no longer require implementation of SLO AFTO penalty files for this unit. The station no longer requires SLO AFTO files or penalties due to a 3D MONICORE upgrade required for EPU operation. Asymmetric feedwater temperature operation (AFTO) is defined as operation in a feedwater heater/string configuration that results in a specified threshold difference as described in Reference 10. To simplify the implementation of the AFTO limits, only the maximum AFTO penalties indicated in Table 10-1 will be implemented when the threshold asymmetry temperature (temperature above which a penalty is required) is exceeded. This will minimize the number of AFTO thermal limit tables in the COLR and core monitoring system.

40F < FWT DELTA$ 55F 30F < FWT DELTA $40F 20F < FWT DELTA$ 30F OF< FWT DELTA$ 20F TABLE 10-1 AFTO Thermal Limit Penalties (Asymmetric Feedwater Heating)

(Reference 10)

MFLCPR 3%

2%

2%

No Penalty LHGRLIMITS MFLPD/MAPRAT 4%

3%

2%

No Penalty The ARTS-based LHGR power-dependent multipliers for AFTO operation are provided in Table 10-2. The flow-dependent multipliers for AFTO in DLO are provided in Table 10-3. The power-and flow-dependent LHGR multipliers were obtained from Reference 2 and were adjusted with the appropriate penalties displayed in Table 10-1 as per Reference 10. PR/PLUOOS + TBSOOS and PR/PLUOOS + RPTOOS values were obtained by taking the most limiting OLMCPR values of the two EOOS conditions, these values are bounding for non-AFTO conditions. The maximum feedwater temperature difference allowed without a thermal limit penalty is 20 °F. Once the temperature difference exceeds 20 °F the maximum penalties from Table 10-1 are applied to the thermal limits. Additionally, no LHGR penalties are required for asymmetric feedwater temperature option while in SLO as previously discussed.

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating limits Report COLR PEACH BOTTOM 3 Rev. 9 Page20of26 TABLEl0-2 AFTO Power Dependent LHGR Multiplier LHGRFAC(P) 20F < FWT DELTA~ 55F (Asymmetric Feedwater Heating)

(References 2 and 10)

Core Core Thermal Power ( % of rated)

EOOS Combination Flow 0

23

<26.7

?.26.7 40 55 65

(%of rated)

LHGRFAC(P) Multiplier

$60 0.488 0.488 0.501 Base 0.718 0.726 0.740 0.784

>60 0.488 0.488 0.501

$60 0.488 0.488 0.501 RPTOOS 0.718 0.726 0.740 0.784

>60 0.488 0.488 0.501

$60 0.488 0.488 0.501 PR/PLUOOS 0.595 0.668 0.721 0.784

>60 0.488 0.488 0.501

$60 0.381 0.381 0.424 TB SOOS 0.610 0.629 0.685 0.784

>60 0.381 0.381 0.400

$60 0.381 0.381 0.424 PR/PLUOOS + TBSOOS 0.595 0.629 0.685 0.784

>60 0.381 0.381 0.400

$60 0.488 0.488 0.501 PR/PLUOOS + RPTOOS 0.595 0.668 0.721 0.784

>60 0.488 0.488 0.501 TABLE 10-3 AFTO Flow Dependent LHGR Multiplier LHGRFAC(F) 20F < FWT DELTA~ 55F (Asymmetric Feedwater Heating)

(References 2 and 10)

Core Flow ( % of rated)

EOOS Combination 0

I 30 I 33.60 I 70 I

80 I

LHGRFAC(F) Multiplier 85 0.921 0.921 0.921 0.893 0.893 0.921 110 Dual Loop 0.486 I 0.678 I 0.701 I 0.934 I 0.960 I 0.960 100 0.960 0.960 0.960 0.960 0.960 0.960

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating llmits Report MCPRLIMITS COLR PEACH BO'ITOM 3 Rev. 9 Page 21of26 The OLMCPRs during asymmetric feedwater temperature operation with a feedwater temperature difference greater than 20 °F are provided in Table 10-4. The ARTS-based power-dependent MCPR limits for use during AFTO conditions are provided in Table 10-5. The flow-dependent MCPR limits for AFTO are provided in Table 10-6.

The power and flow-dependent OLMCPR curves were obtained from Reference 2 and were adjusted with a 3% penalty for feedwater temperature difference greater than 20 °F as displayed in Table 10-1 as per Reference 10. PR/PLUOOS + TBSOOS and PR/PLUOOS + RPTOOS values were obtained by taking the most limiting OLMCPR values of the two BOOS conditions, these values are bounding for non-AFTO conditions. No MCPR penalties are required for asymmetric temperature differentials less than or equal to 20 °F. Additionally, no MCPR penalties are required for asymmetric feedwater temperature option while in SLO as previously discussed.

TABLEl0-4 AFTO Operating Limit Minimum Critical Power Ratio 20F < FWT DELTAS 55F (Asymmetric Feedwater Heating)

(References 2 and 10)

SCRAM Cycle Exoosure Time

<EOR-2523

~EOR-2523 EOOS Combination Option<1>

MWd/ST MWd/ST BASE B

1.42 1.45 A

1.49 1.53 RPTOOS B

1.46 1.50 A

1.64 1.68 PR/PLUOOS B

1.42 1.45 A

1.49 1.53 TBSOOS B

1.46 1.47 A

1.53 1.57 PR/PLUOOS + TBSOOS B

1.46 1.47 A

NIA NIA PR/PLUOOS + RPTOOS B

1.46 1.50 A

NIA NIA (1) When Tau does not equal O or 1, use linear interpolation.

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating limits Report TABLE 10-5 COLR PEACH BOTTOM 3 Rev. 9 Page 22 of26 AFTO Power Dependent MCPR Limit Adjustments And Multipliers MCPR(P) 20F < FWT DELTA::; SSF (Asymmetric Feedwater Heating)

(References 2 and 10)

Core Core Thermal Power ( % of rated)

EOOS Combination Flow 0

23

<.26.7

?:.26.7 40 55 65 85

(%of 100 rated) Operating Limit MCPR Operating Limit MCPR Multiplier, Kp

.$ 60 2.75 2.75 2.68 1.131 Base 1.352 1.352 1.317

>60 3.08 3.08 2.91

.$ 60 2.75 2.75 2.68 RPTOOS

>60 3.08 3.08 2.91 1.352 1.352 1.317 1.131

_s60 2.75 2.75 2.68

.PR/PLUOOS

>60 3.08 2.91 1.392 1.352 1.317 1.210 3.08

.$ 60 3.75 3.75 3.35 TB SOOS

>60 4.27 3.89 1.659 1.479 1.373 1.155 4.27 PR/PLUOOS + TBSOOS

_s60 3.75 3.75 3.35

>60 4.27 3.89 1.659 1.479 1.373 1.210 4.27 PR/PLUOOS + RPTOOS

.$ 60 2.75 2.75 2.68 1.392 1.352 1.317 1.210

>60 3.08 3.08 2.91 TABLE 10-6 AFTO Flow Dependent MCPR Limits MCPR(F) 20F < FWT DELTA$ 55F (BOC to EOC)(Asymmetric Feedwater Heating)

(References 2 and 10)

Flow MCPR(F)

(%rated)

Limit 0.0 1.80 30.0 1.62 79.0 1.32 110.0 1.32 1.082 1.000 1.082 1.000 1.147 1.000 1.082 1.000 1.147 1.000 1.147 1.000

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating limits Report MAPLHGR LIMITS COLR PEACH BOTI'OM 3 Rev. 9 Page 23 of 26 An appropriate penalty must be applied to MAPLHGR limits under asymmetric feedwater temperature operation (AFrO) for varying temperature differentials as displayed in Table 10-1 as per Reference 10. No MAPLHGR penalties are required for asymmetric feedwater temperature option while in SLO as previously discussed.

TABLE 10-7 AFTO MAPLHGR Reduction Factor (Asymmetric Feedwater Heating)

(References 2 and 10)

AFTO Reduction Factor 20F<FWTDELTA~55F I 0.960

Exelon Nuclear *Nuclear Fuels P3C21 Core Operating Llmits Report COLR PEACH BOTTOM 3 Rev. 9 Page 24of26 11.0 MODES OF OPERATION TABLE 11-1 Modes of Operation (Reference 2)

Supported Operating EOOS Options1 Reeion2 Base, Option A or B Yes Base SLO, Option A or B Yes3 TBSOOS, Option A or B Yes TBSOOS SLO, Option A or B Yes3 RPTOOS, Option A or B Yes RPTOOS SLO, Option A or B Yesj PLUOOS, Option A or B Yes PLUOOS SLO, Option A or B Yes3 PROOS, Option A or B Yes PROOS SLO, Option A or B Yes3 PR/PLUOOS and TBSOOS, Option B Yes PR/PLUOOS and RPTOOS, Option B Yes TBSOOS and RPTOOS, Option A or B No TBSOOS and RPTOOS SLO, Option A or B No TABLE 11-2 Additional Equipment Out of Service Modes of Operation EOOS TCVffSVOOS (controlled via station procedures)

MSIVOOS (controlled via station procedures)

AFTO LFWH (controlled via station procedures) 12.0 METHODOLOGY The analytical methods used in determining the core operating limits have been previously reviewed and approved by the NRC, specifically those described in the following documents:

1. "General Electric Standard Application for Reactor Fuel, NEDE-24011-P-A-22, November 2015 and U.S. Supplement NEDE-24011-P-A-22-US, November 2015.

Modes of operation with thermal limit sets in the COLR

' Operating Region refers to operation on the Power to Flow map with or without FFWTR or AFTO.

Operation not permited in the MELLLA+ Region for Reduced Feedwater Temperature conditions as controlled by station procedures.

3 Operation in SLO not permitted in the MELLLA+ Region as controlled by station procedures.

Exelon Nuclear

  • Nuclear Fuels P3C2 I Core Operating limits Report

13.0 REFERENCES

COLR PEACH BOTTOM 3 Rev. 9 Page 25 of 26

1. "Technical Specifications for Peach Bottom Atomic Power Station Unit 3," Docket No. 50-278, Appendix A to License No. DPR-56.
2. Global Nuclear Fuel Document "Supplemental Reload Licensing Report for Peach Bottom Unit 3, Reload 20, Cycle 21 Extended Power Uprate (EPU)/Maximum Extended Load Line Limit Analysis Plus (MELLLA+)," GNF Document No. 001N3881, Revision 0, July 2015.
3. Global Nuclear Fuel Document "General Electric Standard Application for Reactor Fuel," NEDE-24011-P-A-22, November 2015 and U.S. Supplement NEDE-24011-P-A-22-US, November 2015.
4. Global Nuclear Fuel Document NEDC-33270P Rev. 5, "GNF2 Advantage Generic Compliance with NEDE-24011-P-A (GESTAR II)," May 2013.
5. General Electric Hitachi Document 001N2494-RO, "Peach Bottom EPU Evaluation of Feedwater Temperature vs. Reactor Power for Feedwater Temperature Conditions of Nominal Rated, FWHOOS (Nominal -55°F) and FFWTR (Nominal -90°F)," July 2014. This document is searchable in Exelon EDMS under document number "PEAM-EPU-1 Rev. OOA."
6. General Electric Hitachi Document NED0-33720, "Safety Analysis Report for Peach Bottom Atomic Power Station Units 2 & 3 Maximum Extended Load Line Limit Analysis Plus", Revision 0, September 2014.
7. PECO Calculation PE-0173, "Determination of Total Time Required to Initiate the Trip Signal to the EOC-RPf Circuit Breakers Trip Coils and to Complete the Recirculation Pump Trip," Rev. 1 dated 12/22/98.
8. NotUsed.
9. PECO Calculation PE-0251, Revision 2B, "PRNMS Setpoint Calculation," dated 5/26/15.
10. General Electric Hitachi Document 001N6733-Rl, "Final Evaluation Report Exelon Nuclear Generating Company LLC, Peach Bottom Units 2 & 3, MELLLA+, Asymmetric Feedwater Temperature Operation for EPU/MELLLA+," Revision l, September 2014. This document is searchable in Exelon EDMS under document number "PEAM-EPU-68 Rev. l."
11. Global Nuclear Fuel Document 002N8938, Revision 0, "Fuel Bundle Information Report for Peach Bottom Unit 3 Reload 20 Cycle 21 Extended Power Uprate (EPU)/Maximum Extended Load Line Limit Analysis Plus (MELLLA+) and Extended Power Uprate (EPU)/Maximum Extended Load Line Limit Analysis (MELLLA)," July 2015.
12. Not Used
13. Not Used
14. Exelon TOOi ENSAF ID# ES1500001, Rev. 0, "Final Resolved OPL-3 Parameters for Peach Bottom Unit 3 Cycle 21: EPU/MELLLA+," February 17, 2015.

Exelon Nuclear

  • Nuclear Fuels P3C21 Core Operating Limits Report 0

10 20 30 APPENDIX A COLR PEACH BOTIOM 3 Rev. 9 Page 26 of 26 Power/Flow Operating Map for MELLLA+

(Reference 6)

Core Flow (l\\Db/hr) 40 50 60 70 80 90 100 110 120 120..i-..._._...._.l-l-l--+-l-+-l-......._.._._...._........i..........._~_............ ~

..............._._~

, _._........ 1-.1._,_..._._.__,_.......i............_.1-1_._,....... ~

....... 4741 100% a.TP

!= 3951 MWt

,I i-.,,.l't.-.---'-~~-=-=r==~-,-,,.-~ 100%. Core* FiOw-*- != 102.5 Mlb hr 1

I i

i OJ mm m 1..D----+---:::O:l>----0 110 t

~-

  • l..

~ -

seed 100 54.9 4346 3951 D

100.0 E

100.0 90 F

100.0 3556 G

110.D 21.3 H

100.D 21.3 80 37.4 21.3 3161 83.0 100.0 K

55.0 78.8

?f.

70 t :=

60

=!

"i J 50 55.0 68.4 L

2766

~

==

2370 e ti 1975 ~

40 1580 30 1185 20 790 10 395 0

0 0

10 20 30 40 50 60 70 80 90 100 110 120 Core Flow(%)