ML16125A248

From kanterella
Jump to navigation Jump to search
1RE19 Inspection Summary Report for Steam Generator Tubing
ML16125A248
Person / Time
Site: South Texas 
Issue date: 04/25/2016
From: Georgeson C
South Texas
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NOC-AE-16003364
Download: ML16125A248 (16)


Text

South lexas Project Electric Generating Station P.O. Box 28JJ Wadsworth. Texas 77483 Attention: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 South Texas Project Unit 1 Docket No. STN 50-498 April 25, 2016 NOC-AE-16003364 File No.: G25 10 CFR 50.55a 1RE19 Inspection Summary Report for Steam Generator Tubing Enclosed is the summary report describing the results of the South Texas Project Unit 1 steam generator tube inspection performed during refueling outage 1RE19. The summary report satisfies the reporting requirements of ASME Section XI, Article IWA-6230, and Section 6.9.1.7 of the South Texas Project Technical Specifications. This report provides the information required by Technical Specification 6.8.3.o for maintaining steam generator tube integrity.

There are no commitments in this letter.

If there are any questions regarding this report, please contact either Wendy 'Brost at (361) 972-8516 or me at(361) 972-7806.

Enclosure:

Christopher Georgeson

Manager, Design Engineering Testing & Programs Engineering 1RE19 Inspection Summary Report for Steam G_en!=Jr?tor Tubing (Rev O) of the South Texas Project Electric Generating Sfai'tionTfoHl.*:

- -~- - '.-...- ".i:' -u* *.: '-';:

.~'""'-" '

STI: 34306289

cc:

(paper copy)

Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 1600 East Lamar Boulevard Arlington, TX 76011-4511 Lisa M. Regner Senior Project Manager U.S. Nuclear Regulatory Commission One White Flint North (08H04) 11555 Rockville Pike Rockville, MD 20852 NRC Resident Inspector U. S. Nuclear Regulatory Commission P. 0. Box 289, Mail Code: MN116 Wadsworth, TX 77 483 (electronic copy)

NOC-AE-16003364 Page 2 of 2 Morgan, Lewis & Beckius LLP Steve Frantz, Esquire U.S. Nuclear Regulatory Commission Lisa M. Regner NRG South Texas LP Chris O'Hara Jim von Suskil Skip Zahn CPS Energy Kevin Pollo Cris Eugster L. D. Blaylock Crain Caton & James, P.C.

Peter Nemeth City of Austin Elaina Ball John Wester Texas Dept. of State Health Services Helen Watkins Robert Free

Enclosure NOC-AE-16003364

. Page 1 of 14 1RE19 INSPECTION

SUMMARY

REPORT FOR STEAM GENERATOR TUBl.NG (Rev 0) of the SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION UNIT 1 P.O. BOX289 WADSWORTH, TEXAS 77483 Commercial Operation:

August 25, 1988 Issue l;)a.te:

~~i'!l~~~

1~~}.~

.. **~* ' "-.

~

  • _J.,

Enclosure NOC-AE-16003364 Page 2of14 1RE19 INSPECTION

SUMMARY

REPORT FOR STEAM GENERATOR TUBING (Rev. 0) of the SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION UNIT 1 Prepared By:

Approved By:

~,.

USNRC DOCKET NO.:

OPERATING LICENSE NO.:

COMMERCIAL OPERATION DATE:

fJ~c,lL.

D. C. Sicking

~1 Steam Generator Engineer

~Georgeson Manager, Design Engineering

/Voc;VoC )b c.2f15"2-50-498 NPF-76 August25, 1988 Lt-Z/-/t, Date

~ Date

SOUTH TEXAS PROJECT UNIT 1 Enclosure NOC-AE-16003364 Page 3of14 1RE19 INSPECTION

SUMMARY

REPORT FOR STEAM GENERATOR TUBING Introduction This summary report describes the inspection of steam generator tubing at South Texas Project (STP) Unit 1 performed during refueling outage 1RE19 beginning 10/17/2015 and ending with breaker closure on 12/20/2015. Eddy current inspection, sludge lancing, and Foreign Object Search and Retrieval (FOSAR) were conducted in steam generators (SGs) 1A, 1 B, 1C and 1 D.

Additional inspections of the secondary side of SGs 1 A, 1 C and 1 D were also performed.

The eddy current inspection performed during 1.RE19 completes the first inspection of the Technical Specification (TS) Second Interval for all STP Unit 1 SGs. The outage was performed following 167.3 effective full power months cumulative service with the Delta 94 replacement SGs. This report provides the information required by TS 6.8.3.o for maintaining SG tube integrity and the reporting requirements of TS 6.9.1.7.

Scope of Examination The 1RE19 outage initial inspection plan, "1RE19 Steam Generator In-Service Outage Plan October 2015"., identified the SG tube areas to be examined by eddy current testing and the related procedures to be used during the inservice inspection. The inspection plan was applicable to SGs 1 A, 1 B, 1 C and 1 D. A Degradation Assessment written prior to the outage established the following scope of primary and secondary side inspections.

Primary Side Inspection Scope As required by the Electric Power Research Institute (EPRI) Examination Guidelines, the 1RE19 outage inspection program addressed the known degradation mechanism(s) observed in STP Unit 1 during prior inspections as well as those regarded as potential degradation mechanisms.

The primary side inspection included the following elements.

Bobbin Coil Inspection Full length bobbin coil inspection of 100% of the outer three peripheral tubes from tube end to tube end, including ten tubes inwards into the no-tube lane from the periphery to aid in foreign object detection.

50% full length bobbin coil inspection of all non-peripheral tubes 20% bobbin probe inspection of the upper tube support plate (TSP) hot leg to upper TSP cold leg (U-Bend) of Rows 1 and 2 Rotating Coil Inspection - Straight Section

+Point probe inspection of outer three peripheral tubes and divider lane top of tube sheet (TTS)

+6 inches/-3 inches, including hot leg (HL} and cold leg (CL), to aid in foreign object detection 20% sample +Point probe in~pection of tube sheet hot {TSH) +6 inches/-3 inches 20% sample +Point probe iri~pec~iori ofTSH +6 inches/-16 inches in tubes with bulges and over-expansions

Rotating Coil Inspection - Special Interest Enclosure NOC-AE-16003364 Page 4of14

+Point probe inspection of all previously identified dents and dings >5 volts (V)

+Point probe inspection of all prior and 1RE19 "I-code" and/or non-quantifiable indications as determined by bobbin coil inspection or any previously reported signal that has changed

+Point probe inspection of possible loose parts (PLPs) in the eddy current database as identified by previous eddy current inspections

+Point probe inspection of all observed Priority 1 or 2 foreign objects identified during 1RE16 secondary side video inspections and not removed, including a minimum of two tube locations surrounding the object

+Point probe inspection of a minimum of two tube locations surrounding any newly identified PLP

+Point probe inspection of a minimum of two tube locations surrounding newly identified foreign objects that are classified as Priority 1 or Priority 2

+Point probe inspection of all tube-to-tube wear (TTW) indications detected by bobbin coil

  • +Point probe inspection of all reportable proximity (PRO) indications *.. * *

+Point probe inspection of all manufacturing burnish marks (MBM) bobbin coil indications that have increased by 2:0.5 V including both new and changed bobbin coil MBM indications

+Point probe inspection of prior inspection MBMs that are TTW candidates as evidenced by matching MBMs on adjacent tubes at a common elevation

+Point probe inspection of wear indications left in service Other Primary-Side Inspections Video inspection of all installed plugs Video inspection of hot and cold leg bowl drain area looking for thinning or missing cladding and associated wastage, if any Stud hole gauging on SG 1 C Secondary Side Inspection Scope TTS FOSAR in all four SGs including annulus and no-tube lane TTS in-bundle FOSAR as follows:

SG 1A inspect every fourth column both hot leg and cold leg SG 1 B inspect every fourth column both hot leg and cold leg SG 1 C inspect every fourth column both hot leg and cold leg SG 1 D inspect every second column both hot leg and cold leg (Note 1)

Ultra-sludge lancing on all four SGs Steam Drum inspections in SG 1 C and SG 1 D Upper Steam Drum inspection in SG 1 C Video probe inspection of ninth support plate on SG 1A Tube scale profiling and trefoil profiling on SG 1A and SG 1 D FOSAR of all foreign objects left in service during 1RE16, if reachable by tooling FOSAR of all PLPs (previous inspection and 1RE19) identified by eddy current inspection, if reachable by tooling

_ *: Note 1.: Loose parts tend to accumulate preferentially in SG 1 D due to the feedwater header

,~.t.,,.d>r~:htpiping configuration. Generally 50% of steam generator lop$e:.parts}deposit into SG 1 D.

Inspection Expansion Enclosure NOC-AE-16003364 Page 5 of 14 As discussed below, a volumetric indication (VOL) was identified in tube D-R30C78 within the hot leg tubesheet hard sludge via the +Point probe. This indication lead to expansion of the top of the tubesheet +Point probe program to include all tubes within the sludge pil*e region of all four SGs, plus a minimum two tube border. No additional VOL indications were observed in the scope expansion.

The cold leg sides of all STP SGs do not contain a hardened sludge pile nor sludge collars, thus no inspection expansion was performed in cold leg tubes.

Primary Side Examination Results Table 1 presents a summary of the tube non-destructive examination (NOE) indication results based on available data relevant to evaluating tube integrity. This summary includes redundant.

indications that may have been detected by multiple inspection programs.

No crack-like indications or indications of foreign object wear were identified during the 1RE19 inspection. One possible new degradation mechanism was found - a volumetric indication under the hard sludge deposits. One new occurrence of TSP wear, an existing degradation mechanism, was also identified during the 1RE19 inspection.

Table 1: STP Unit 1 1 RE19 Eddy Current Inspection - Final Indication Listing Indication Condition Number of Indications SG1A SG18 SG1C SG1D Total ONG Ding (Freespan Only) 464 30 330 185 1009 DNS Distorted Ding Indication Not 18 11 17 35 81 Confirmed DSS Distorted Support Signal 1

1 2

2 6

INF Indication Not Found 3

2 3

2 10 INR Indication Not Reportable 58 28 36 162 284 MBM Manufacturing Burnish Mark 247 226 260 303 1036 NOD No Detectable Degradation 8085 8321 8126 9089 33621 NDF No Degradation Found 155 31 19 10 215 NQS Non-Quantifiable Signal 35 49 43 27 154 PCT Percent 1

1 0

1 3

PIO Positive Identification 0

1 0

1 2

PLP Possible Loose Part 1

2 0

30 33 PRC Previous Rotating Probe Call 0

0 0

1 1

PRO Tube Proxim'ity Measurement 16 7

4 0

27 PVN Permeability Variation 0

0 0

1 1

VOL Volumetric 1

1 3

8 13

Enclosure NOC-AE-16003364 Page 6of14 Inspection Results - Volumetric Indication Under Hard Sludge Deposits A volumetric indication was identified in tube D-R30C78 as part of the base scope of inspection to perform a +Point probe inspection of two tube locations surrounding Priority 2 foreign object 00028. The indication was located 0.2 inch above the hot leg tubesheet. The 0.08 V indication was sized by Examination Technique Specification Sheet (ETSS) 21998.1 to be 12% through-wall (TW). The dimension of the indication was approximately 0.1 inch in the axial and circumferential direction.

A review of prior inspection +Point probe and pancake coil information showed that a +Point probe signal was discernable, but not reportable, in the 1RE16 inspection data. The indication was not present in inspections performed in 1.RE09 (pre-service inspection), 1RE10 and 1RE13.

The +Point probe data showed that the sludge collar was one inch thick at the location of the VOL in 1RE19. A review of prior cycle +Point probe data showed that the sludge collar was also one inch thick at this location in 1RE13 and 1RE16.

The location of the indication was retested with the +Point probe as well as a magnetically-biased +Point probe and.a Ghent probe. All three of these probes detected the indication.

The cause of the indication is unknown at this time. Possible causes include:

a false call, loose part wear, a manufacturer surface blemish a corrosion induced pit, or volumetric intergranular attack (IGA)

The single volumetric call in tube D-R30C78 did not require in-situ testing.

Because this volumetric indication could not definitely be associated with mechanical wear, STPNOC decided to plug the tube. In the STPNOC response to Generic Letter 97-05, STP informed the NRC that Eddy Current Testing (ECT) flaw sizing would only be used to leave tubes in-service for wear indications. All potential corrosion related degradation mechanisms are plugged on detection.

A final causal analysis report is expected in June 2016 - A copy of this report will be sent to the NRC.

-.,*'}::_*

Inspection Results - Foreign Object Wear - PLPs Enclosure NOC-AE-16003364 Page 7of14 Foreign object wear, while not affecting a large population of tubes, is an existing degradation mechanism at STP Unit 1.

A total of eight PLP indications were identified at the TTS, none of which were associated with a wear indication or visible wear. Table 2 lists the PLPs located near the TTS for 1RE19. There were no PLPs in SG 1 C. All of the TTS PLPs were associated with an object that had been noted as part of the FOSAR program, except for PLP-A-001. A video probe examination was performed near the reported location of PLP-A-001 and no object or wear was found.

Table 2: 1RE19 PLP Indications at the TTS SG PLP Row Col Leg Location Inch Visually Comments Verified A

PLP-A-001 59 59 HL TSH 0.12 Yes Nothing observed B

PLP-B-001 88 58 HL TSH 0.12 Yes 1RE19 Object 80003 B

PLP-B-002 87 59 HL TSH 0.09 Yes 1RE19 Object 80003 c

No PLPs 0

PLP-0-008 122 90 HL TSH 0

Yes 1RE19 Object 00021 0

PLP-0-009 122 94 HL TSH 0.07 Yes 1RE19 Object 00017 0

PLP-0-013 54 112 HL TSH 0.17 Yes

. 1RE19 Object 00042 0

PLP-0-014 57 113 HL TSH 0.09 Yes 1 RE 19 Object 00041 0

PLP-0-018 32 152 HL TSH 0.11 Yes 1RE19 Object 00004 A total of 25 PLP indications were identified at locations* above the TTS located in the vicinity of the flow distribution baffle (FOB). Table 3 lists the PLPs located near the FOB. All of the FOB PLPs were found in SG 10. None of these PLPs were associated with a wear indication. Each of the PLPs in Table 3 were present in the 1RE16 inspection. These PLP indications are due to remnants of a section of stabilizer wire that had entered steam generator 1 O prior to the 1RE12 outage. A +Point probe inspection of two tube locations surrounding each FOB PLP was conducted. There were no wear indications in any of these surrounding tubes.

SG D

D D

D D

D D

D D

D D

D D

D D

D D

D D

D D

D D

D D

Enclosure NOC-AE-16003364 Page 8of14 Table 3: 1RE19 PLP Indications at the FOB PLP Row Col Leg Location Inch PLP-D-001 78 36 HL FBH

-0.65 PLP-D-002 78 36 HL FBH 0.27 PLP-D-003 87 49 HL FBH

-0.55 PLP-D-004 110 56 HL FBH 1.06 PLP-D-005 111 57 HL FBH 2.16 PLP-D-006 126 78 HL FBH 0.93 PLP-D-007 108 90 HL FBH 0.76 PLP-D-010 102 98 HL FBH 1.19 PLP-D-011 75 111 HL FBH 0.71 PLP-D-012 75 111 HL FBH 1.12

. PLP-D-015

85. 119 HL FBH 0.51 PLP-D-016 76 134 HL FBH

-0.3 PLP-D-017 76 134 HL FBH 0.16 PLP-D-019 127 71 CL FBC 1.51 PLP-D-020 44 76 CL FBC

-0.61 PLP-D-021 44 76 CL FBC 0.28 PLP-D..;022 121 91 CL FBC

-0.38 PLP-D-023 121 91 CL FBC 0.48 PLP-D-024 50 100 CL FBC

-0.11 PLP-D-025 114 110 CL FBC 1.66 PLP-D-026 116 110 CL FBC 1.5 PLP~D-027 115 111 CL FBC 0.18 PLP-D-028 115 111 CL FBC 1.03 PLP-D-029 80 128 CL FBC

-0.26 PLP-D-030 31 151 CL FBC

-0.64 None of the PLP indications required in-situ proof of pressure or leakage testing to demonstrate tube integrity.

All instances of foreign object wear from prior cycles were inspected.in 1RE19. In each case, the object that caused the wear has been removed. None of the indications have changed since the 1RE16 inspection.

Inspection Results - TSP Wear Enclosure NOC-AE-16003364 Page 9of14 TSP wear is categorized as an existing degradation mechanism. During the STP Unit 1 SG inspections conducted during 1RE16, two tubes were found to have TSP wear. Location A-R126C88-06H had a reported indication of 6% TW at 1 RE16, as sized by bobbin. During 1RE19, this same location was sized by bobbin to be 5% TW. Location B-R3C155-06H had a reported indication of 9% TW at 1RE16, as sized by bobbin. At 1RE19, this location was sized by bobbin to be 9% TW.

There was one new location with a TSP wear indication reported for the first time in 1RE19. The indication at location D-R3C41-08C was sized by bobbin to be 10% TW. This tube was not tested in 1 RE16. A review of the 1RE13 data showed that this indication was 8% TW at that time. The probability of detection (POD) is low for an 8% TW indication.

All three of these TSP wear indications are located near the periphery or the no-tube lane of the tube buil'cffe." None of the TSP wear indications required in-situ testing or plugging:-*..

During the review of previous cycles' inspection results, STPNOC noted an error in the 1RE16 Inspection Summary Report. The 1RE16 report indicated that three TSP wear indications were observed. A review of the data during 1RE19 revealed that only two TSP wear indications were observed as described above.

Potential Degradation Mechanisms The Degradation Assessment categorized anti-vibration bar wear and tube-to-tube wear as potential degradation mechanisms. The results are as follows:

Mechanical Wear Indications at Anti-Vibration Bars There were no tubes in the STP Unit 1 SGs with indications of wear at the anti-vibration bars.

Mechanical Wear Indications due to Tube-to-Tube Contact There were no tubes in the STP Unit 1 SGs with indications of wear due to tube-to-tube contact.

A review of MBM and tube proximity measurement (PRO) indications, with follow-up inspection via +Point probe where applicable, did not indicate the presence of weaL Volumetric Indications Table 1, above, indicates that 13 VOL indications were identified in the 1RE19 inspection. They are attributed to the following mechanisms:

Three are associated with the three TSP wear indications. As discussed above, two of the TSP wear indications were identified in previous inspections and one was reported for the first time in 1RE19.

One is associated with the sludge pile volumetric indication in tube D-R30C78.

Nine are associated with foreign object wear from prior cycles. There was no change in these indications from 1RE16.

Non-Degradation Mechanisms Enclosure NOC-AE-16003364 Page 10of14 Indications first reported with potential flaw-like characteristics in the STP Unit 1 SGs may include indications initially reported as distortions or pre-existing signals such as manufacturing burnish marks or dents and dings (MBI, MBM, DNI, DNS), benign indications (DFI, DFS, OSI, DSS), anomalous signals at the tubesheet or elsewhere (DTI, DTS), non-quantifiable signals in the sludge pile region (NQI, NQS) and permeability indications (PVN).. The character of I-code signals, when observed, is determined by history review, Lead Analyst Review, or by +Point probe examination. All other I-code indications, other than the three TSP wear indications discussed above, were dispositioned as non-flaw conditions. There were no unresolved I-codes for 1RE19.

PVNs are technically not I-code signals but rather interferences that can compromise detection of flaw signals. There were no flaws associated with PVN indications.

MBMs are conditions where shallow volumetric scuffs were introduced into the tubes exterior during the final tube polishing. Of concern are new MBMs that exhibited increasing voltage as such a change may indicate a condition other than a manufacturing anomaly. No new MBMs were identified and no MBM increased by more than 0.5V.

There were 27 tubes with PRO indications (tubes in proximity) in the STP Unit 1 SGs. A review of historical data reveals that these proximity indications were present in previous inservice inspections. Follow-up inspection with +Point indicate that there were no flaw-like indications associated with any PRO indication.

Ding (ONG) is a baseline indication where the tubing inside diameter is less than normal. The dings are fabrication induced and not expected to grow in size. The Degradation Assessment specified that all dings greater than 5V that were reported in the baseline examination would be inspected with a +Point coil. 85 dings greater than 5V were identified in the STP Unit 1 SGs; these dings were inspected with a +Point probe and no degradation was found.

The 1RE16 inspection ONG indication at location B-R127C79 had a 47.94V bobbin signal at tubesheet cold (TSC) +3.21. The tube was dented when the SG was raised to a vertical position during installation when a wedge fell thru the downcomer, striking a peripheral tube. The wedge was removed during replacement of the SGs. The size of this ONG indication did not allow a standard size bobbin probe to pass. This location was inspected with a down sized probe during the 1RE19 inspection and no defect was found (NDF). This tube was administratively plugged in order to reduce future dose associated with probe change out.

Bulge (BLG) is a condition where the tubing outside diameter is greater than normal. An overexpansion (OXP) is a similar condition associated with anomalies in the tubesheet. There were no new BLG/OXP locations identified in 1RE19. Existing BLG/OXP locations were inspected with a +Point probe. The results of the tests were that no defects were found (NDF).

Plug Inspection Results All installed plugs were confirmed to be present and free from degradation.

,;i::

Bowl Inspection Results Enclosure NOC-AE-16003364 Page 11 of 14 A visual inspection of the SG channel head bowl was performed in all SGs during 1RE19, based on industry operating experience identified in the Degradation Assessment. Visual inspections of the SG hot leg and cold leg divider plate base, and with particular attention to the bottom 36 inch radius of the bowl, were performed in accordance with Westinghouse NSAL-12-01 using the SG manway channel head bowl cameras. Satisfactory inspection results were observed in all SGs. No degradation was observed.

Stud Hole Gauging Stud hole go/no-go gauging and stud gauging were performed on SG 1 C. All results were satisfactory. Stud holes and studs are gauged to identify thread wear that may occur. No defects were found.

Tube Repair Summary Two tubes were plugged in 1RE19. Tube D-R30C78 was plugged due to the conservative decision to treat the volumetric indication as a pit. As discussed above, only mechanical wear is left in-service based on indication sizing. Since wear could not definitively be determined to be the cause of the indication, the tube was plugged. Another tube, B-R127C79, was administratively plugged for an abnormally large dent which prevented inspection with a standard size bobbin probe. Table 4 lists the total tubes plugged for each Unit 1 SG.

Table 4: Total Tubes Plugged Per Steam Generator Steam Generator Total Tubes Plugged SG Percent Plugged 1A 33 0.435 18 41 0.541 1C 26 0.343 1D 14 0.185 Summary of Secondary Side Inspection and Maintenance Plan The following is a summary of the secondary side inspection and maintenance plan:

TTS FOSAR in all four SGs generators including annulus and no-tube lane TTS in-bundle FOSAR as follows:

SG 1A inspect every fourth column both hot leg and cold leg SG 1 B inspect every fourth column both hot leg and cold leg SG 1 C inspect every fourth column both hot leg and cold leg SG 1 D inspect every 2nd column both hot leg and cold leg Ultra-sludge lancing on all four SGs Steam Drum inspections in SG 1 C and SG 1 D Upper Steam Drum inspection in SG 1 C Video probe inspection of 9th support plate on SG 1A FOSAR of all foreign objects left in service during 1 RE16, if reachable by tooling

,,. 's r,-~('C.' ;;*.'*:*: '

  • FOSAR of all PLPs identified by eddy current inspection, if reachable by tooling

Secondary Side Inspection and Maintenance Results Sludge Lancing Enclosure NOC-AE-16003364 Page 12of14 All four STP Unit 1 SGs were sludge lanced. Table 5 provides a summary of the mass of sludge collected from sludge lancing operations.

Table 5: Mass of Sludge Collected During 1RE19 Steam Generator 1RE19 Sludge Weight (lbs}

1 A - Tubesheet 22.2 1 B - Tubesheet 45.6 1 C - Tubesheet 52.2 1 D - Tubesheet 19.5 Post-lance inspections revealed that the top of the tubesheet of all four SGs are generally clean with essentially all sludge removed. No anomalies were noted on any tubesheet location. The kidney region, encompassing the tubes within approximately rows 19-35 from columns 72-84, has hardened collars at the TTS, all less than 1.125 inches in thickness. The hardened sludge pile has not grown measurably since 1RE16.

Steam Drum STP performed visual observations of the steam drums for SG 1 C and SG 1 D to assess the condition of the steam drum and to ensure reliable operations until the next inspection period.

The steam drums were inspected for erosion, mechanical damage, cracked welds, corrosion, foreign material and any unusual conditions. The upper steam drum was also inspected in SG 1C.

The steam drum inspections revealed no abnormal conditions - No defects were found.

ln-.Bundle Inspection of the Ninth Tube Support Plate STP performed an in-bundle inspection of the ninth TSP of SG 1 A in order to obtain Visual information on the deposit loading in the upper region of the tube bundle. Video probes were deployed from the tube lane using extensions that permitted visual observation of flow slots, tube surfaces, and trefoil ligaments.

The inspection showed a thin layer of magnetite covering the TSP top surface, along with some loose deposits but not to any significant extent. Scale provided a continuous cover of all the tube surfaces with the exception of tubes nearest the no-tube lane. The tubes near the no-tube lane are minimally fouled. No deposit bridging across the trefoil to tube outside diameter (OD) surface nor departures from the expected appearance of the TSP ligaments were observed.

Foreign Object Mapping and Retrieval Enclosure NOC-AE-'16003364 Page 13of14 FOSAR was performed at the top of the tubesheet, the tube bundle-shell annulus and the tube lane in all four SGs. A total of 81 foreign objects were identified during the top of tubesheet video probe inspections. During the eddy current program, eight PLP calls were reported. As required by EPRI guidelines, coordination between the eddy current and secondary visual inspection results was maintained. Top of the tubesheet tube locations showing PLP signals by eddy current were visually-inspected to identify the source of the signal. In addition, all top of the tubesheet tube locations where foreign objects were identified during visual inspections were included in the top of tubesheet +Point probe inspection program.

There was one Priority 1 object that was not retrievable during the 1RE16 inspection (object 10039, located at D-R120C68-HL). Object 10039 was not retrievable because one end was fixed in place in sludge on the top of the tubesheet. This object was evaluated and it was determined that the tubes adjacent to 10039 could remain in service without exceeding structural and leakage integrity criteria for the operating interval of Unit 1 Cycles 17 through 19.

An inspection of this area in 1RE19 showed that the sludge was no longer on the tubesheet and the wire object was no longer present. Wear was not visible, nor was wear detected by ECT. It is likely that the object was sludge lanced out of the SG.

Based on existing wear analyses and top of the tubesheet velocity maps, prioritization criteria were developed and used to assign priorities to each of the identified foreign objects. Foreign objects were assigned priorities based on the characteristics of the object and its location on the tubesheet:

Priority 1 foreign objects are those which cannot be left in the SGs and justify a three-cycle operational assessment without further evaluation or additional remedial measures.

Priority 2 foreign objects can be left in arid operate for three cycles, but still have the potential for wear and will need to be addressed in future inspection outages.

Priority 3 foreign objects cannot cause wear of any significance and may be left in the steam generator indefinitely.

Priority 1 and Priority 2 objects, whether they were retrieved or not, were tested and bound by a

+Point probe to provide assurance that they had not caused wear, in accordance with the EPRI Integrity Assessment Guidelines.

There were 36 objects that could not be removed from the SGs. This includes 21 Priority 3 objects, 15 Priority 2 objects and zero Priority 1 objects. Each identified foreign object not removed from the respective SG was subjected to a foreign object wear analysis to support the planned operating period through Cycle 22.

Condition Monitoring Conclusion Enclosure NOC-AE-16003364 Page 14of14 Based on the Condition Monitoring evaluation, inservice inspection of tubes in service during Cycle 19 confirms that they all meet the structural integrity requirements of Steam Generator Integrity Assessment Guidelines, Revision 3. Ne.ither the small volumetric.indication discovered in SG 1 D nor the minor tube support plate wear on tube D-R3C41-08C challenge structural integrity limits. Since no degradation mechanisms challenging structural integrity limits were detected during the 1RE19 inspection and no primary-to-secondary leakage was observed prior to the end of Cycle 19, the condition monitoring assessment requirements for SG operation for Cycles 17, 18, and 19 are satisfied. With no significant indications of tube degradation, in-situ tests were not required. No tubes were pulled during 1RE19. No challenges to the SG Performance Criteria were identified; therefore, the condition monitoring requirements for the Unit 1 replacement steam generator tube bundles at the end of Cycle 19 are satisfied. The next Unit 1 SG inspection is scheduled for refueling outage 1 RE22.

South lexas Project Electric Generating Station P.O. Box 28JJ Wadsworth. Texas 77483 Attention: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 South Texas Project Unit 1 Docket No. STN 50-498 April 25, 2016 NOC-AE-16003364 File No.: G25 10 CFR 50.55a 1RE19 Inspection Summary Report for Steam Generator Tubing Enclosed is the summary report describing the results of the South Texas Project Unit 1 steam generator tube inspection performed during refueling outage 1RE19. The summary report satisfies the reporting requirements of ASME Section XI, Article IWA-6230, and Section 6.9.1.7 of the South Texas Project Technical Specifications. This report provides the information required by Technical Specification 6.8.3.o for maintaining steam generator tube integrity.

There are no commitments in this letter.

If there are any questions regarding this report, please contact either Wendy 'Brost at (361) 972-8516 or me at(361) 972-7806.

Enclosure:

Christopher Georgeson

Manager, Design Engineering Testing & Programs Engineering 1RE19 Inspection Summary Report for Steam G_en!=Jr?tor Tubing (Rev O) of the South Texas Project Electric Generating Sfai'tionTfoHl.*:

- -~- - '.-...- ".i:' -u* *.: '-';:

.~'""'-" '

STI: 34306289

cc:

(paper copy)

Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 1600 East Lamar Boulevard Arlington, TX 76011-4511 Lisa M. Regner Senior Project Manager U.S. Nuclear Regulatory Commission One White Flint North (08H04) 11555 Rockville Pike Rockville, MD 20852 NRC Resident Inspector U. S. Nuclear Regulatory Commission P. 0. Box 289, Mail Code: MN116 Wadsworth, TX 77 483 (electronic copy)

NOC-AE-16003364 Page 2 of 2 Morgan, Lewis & Beckius LLP Steve Frantz, Esquire U.S. Nuclear Regulatory Commission Lisa M. Regner NRG South Texas LP Chris O'Hara Jim von Suskil Skip Zahn CPS Energy Kevin Pollo Cris Eugster L. D. Blaylock Crain Caton & James, P.C.

Peter Nemeth City of Austin Elaina Ball John Wester Texas Dept. of State Health Services Helen Watkins Robert Free

Enclosure NOC-AE-16003364

. Page 1 of 14 1RE19 INSPECTION

SUMMARY

REPORT FOR STEAM GENERATOR TUBl.NG (Rev 0) of the SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION UNIT 1 P.O. BOX289 WADSWORTH, TEXAS 77483 Commercial Operation:

August 25, 1988 Issue l;)a.te:

~~i'!l~~~

1~~}.~

.. **~* ' "-.

~

  • _J.,

Enclosure NOC-AE-16003364 Page 2of14 1RE19 INSPECTION

SUMMARY

REPORT FOR STEAM GENERATOR TUBING (Rev. 0) of the SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION UNIT 1 Prepared By:

Approved By:

~,.

USNRC DOCKET NO.:

OPERATING LICENSE NO.:

COMMERCIAL OPERATION DATE:

fJ~c,lL.

D. C. Sicking

~1 Steam Generator Engineer

~Georgeson Manager, Design Engineering

/Voc;VoC )b c.2f15"2-50-498 NPF-76 August25, 1988 Lt-Z/-/t, Date

~ Date

SOUTH TEXAS PROJECT UNIT 1 Enclosure NOC-AE-16003364 Page 3of14 1RE19 INSPECTION

SUMMARY

REPORT FOR STEAM GENERATOR TUBING Introduction This summary report describes the inspection of steam generator tubing at South Texas Project (STP) Unit 1 performed during refueling outage 1RE19 beginning 10/17/2015 and ending with breaker closure on 12/20/2015. Eddy current inspection, sludge lancing, and Foreign Object Search and Retrieval (FOSAR) were conducted in steam generators (SGs) 1A, 1 B, 1C and 1 D.

Additional inspections of the secondary side of SGs 1 A, 1 C and 1 D were also performed.

The eddy current inspection performed during 1.RE19 completes the first inspection of the Technical Specification (TS) Second Interval for all STP Unit 1 SGs. The outage was performed following 167.3 effective full power months cumulative service with the Delta 94 replacement SGs. This report provides the information required by TS 6.8.3.o for maintaining SG tube integrity and the reporting requirements of TS 6.9.1.7.

Scope of Examination The 1RE19 outage initial inspection plan, "1RE19 Steam Generator In-Service Outage Plan October 2015"., identified the SG tube areas to be examined by eddy current testing and the related procedures to be used during the inservice inspection. The inspection plan was applicable to SGs 1 A, 1 B, 1 C and 1 D. A Degradation Assessment written prior to the outage established the following scope of primary and secondary side inspections.

Primary Side Inspection Scope As required by the Electric Power Research Institute (EPRI) Examination Guidelines, the 1RE19 outage inspection program addressed the known degradation mechanism(s) observed in STP Unit 1 during prior inspections as well as those regarded as potential degradation mechanisms.

The primary side inspection included the following elements.

Bobbin Coil Inspection Full length bobbin coil inspection of 100% of the outer three peripheral tubes from tube end to tube end, including ten tubes inwards into the no-tube lane from the periphery to aid in foreign object detection.

50% full length bobbin coil inspection of all non-peripheral tubes 20% bobbin probe inspection of the upper tube support plate (TSP) hot leg to upper TSP cold leg (U-Bend) of Rows 1 and 2 Rotating Coil Inspection - Straight Section

+Point probe inspection of outer three peripheral tubes and divider lane top of tube sheet (TTS)

+6 inches/-3 inches, including hot leg (HL} and cold leg (CL), to aid in foreign object detection 20% sample +Point probe in~pection of tube sheet hot {TSH) +6 inches/-3 inches 20% sample +Point probe iri~pec~iori ofTSH +6 inches/-16 inches in tubes with bulges and over-expansions

Rotating Coil Inspection - Special Interest Enclosure NOC-AE-16003364 Page 4of14

+Point probe inspection of all previously identified dents and dings >5 volts (V)

+Point probe inspection of all prior and 1RE19 "I-code" and/or non-quantifiable indications as determined by bobbin coil inspection or any previously reported signal that has changed

+Point probe inspection of possible loose parts (PLPs) in the eddy current database as identified by previous eddy current inspections

+Point probe inspection of all observed Priority 1 or 2 foreign objects identified during 1RE16 secondary side video inspections and not removed, including a minimum of two tube locations surrounding the object

+Point probe inspection of a minimum of two tube locations surrounding any newly identified PLP

+Point probe inspection of a minimum of two tube locations surrounding newly identified foreign objects that are classified as Priority 1 or Priority 2

+Point probe inspection of all tube-to-tube wear (TTW) indications detected by bobbin coil

  • +Point probe inspection of all reportable proximity (PRO) indications *.. * *

+Point probe inspection of all manufacturing burnish marks (MBM) bobbin coil indications that have increased by 2:0.5 V including both new and changed bobbin coil MBM indications

+Point probe inspection of prior inspection MBMs that are TTW candidates as evidenced by matching MBMs on adjacent tubes at a common elevation

+Point probe inspection of wear indications left in service Other Primary-Side Inspections Video inspection of all installed plugs Video inspection of hot and cold leg bowl drain area looking for thinning or missing cladding and associated wastage, if any Stud hole gauging on SG 1 C Secondary Side Inspection Scope TTS FOSAR in all four SGs including annulus and no-tube lane TTS in-bundle FOSAR as follows:

SG 1A inspect every fourth column both hot leg and cold leg SG 1 B inspect every fourth column both hot leg and cold leg SG 1 C inspect every fourth column both hot leg and cold leg SG 1 D inspect every second column both hot leg and cold leg (Note 1)

Ultra-sludge lancing on all four SGs Steam Drum inspections in SG 1 C and SG 1 D Upper Steam Drum inspection in SG 1 C Video probe inspection of ninth support plate on SG 1A Tube scale profiling and trefoil profiling on SG 1A and SG 1 D FOSAR of all foreign objects left in service during 1RE16, if reachable by tooling FOSAR of all PLPs (previous inspection and 1RE19) identified by eddy current inspection, if reachable by tooling

_ *: Note 1.: Loose parts tend to accumulate preferentially in SG 1 D due to the feedwater header

,~.t.,,.d>r~:htpiping configuration. Generally 50% of steam generator lop$e:.parts}deposit into SG 1 D.

Inspection Expansion Enclosure NOC-AE-16003364 Page 5 of 14 As discussed below, a volumetric indication (VOL) was identified in tube D-R30C78 within the hot leg tubesheet hard sludge via the +Point probe. This indication lead to expansion of the top of the tubesheet +Point probe program to include all tubes within the sludge pil*e region of all four SGs, plus a minimum two tube border. No additional VOL indications were observed in the scope expansion.

The cold leg sides of all STP SGs do not contain a hardened sludge pile nor sludge collars, thus no inspection expansion was performed in cold leg tubes.

Primary Side Examination Results Table 1 presents a summary of the tube non-destructive examination (NOE) indication results based on available data relevant to evaluating tube integrity. This summary includes redundant.

indications that may have been detected by multiple inspection programs.

No crack-like indications or indications of foreign object wear were identified during the 1RE19 inspection. One possible new degradation mechanism was found - a volumetric indication under the hard sludge deposits. One new occurrence of TSP wear, an existing degradation mechanism, was also identified during the 1RE19 inspection.

Table 1: STP Unit 1 1 RE19 Eddy Current Inspection - Final Indication Listing Indication Condition Number of Indications SG1A SG18 SG1C SG1D Total ONG Ding (Freespan Only) 464 30 330 185 1009 DNS Distorted Ding Indication Not 18 11 17 35 81 Confirmed DSS Distorted Support Signal 1

1 2

2 6

INF Indication Not Found 3

2 3

2 10 INR Indication Not Reportable 58 28 36 162 284 MBM Manufacturing Burnish Mark 247 226 260 303 1036 NOD No Detectable Degradation 8085 8321 8126 9089 33621 NDF No Degradation Found 155 31 19 10 215 NQS Non-Quantifiable Signal 35 49 43 27 154 PCT Percent 1

1 0

1 3

PIO Positive Identification 0

1 0

1 2

PLP Possible Loose Part 1

2 0

30 33 PRC Previous Rotating Probe Call 0

0 0

1 1

PRO Tube Proxim'ity Measurement 16 7

4 0

27 PVN Permeability Variation 0

0 0

1 1

VOL Volumetric 1

1 3

8 13

Enclosure NOC-AE-16003364 Page 6of14 Inspection Results - Volumetric Indication Under Hard Sludge Deposits A volumetric indication was identified in tube D-R30C78 as part of the base scope of inspection to perform a +Point probe inspection of two tube locations surrounding Priority 2 foreign object 00028. The indication was located 0.2 inch above the hot leg tubesheet. The 0.08 V indication was sized by Examination Technique Specification Sheet (ETSS) 21998.1 to be 12% through-wall (TW). The dimension of the indication was approximately 0.1 inch in the axial and circumferential direction.

A review of prior inspection +Point probe and pancake coil information showed that a +Point probe signal was discernable, but not reportable, in the 1RE16 inspection data. The indication was not present in inspections performed in 1.RE09 (pre-service inspection), 1RE10 and 1RE13.

The +Point probe data showed that the sludge collar was one inch thick at the location of the VOL in 1RE19. A review of prior cycle +Point probe data showed that the sludge collar was also one inch thick at this location in 1RE13 and 1RE16.

The location of the indication was retested with the +Point probe as well as a magnetically-biased +Point probe and.a Ghent probe. All three of these probes detected the indication.

The cause of the indication is unknown at this time. Possible causes include:

a false call, loose part wear, a manufacturer surface blemish a corrosion induced pit, or volumetric intergranular attack (IGA)

The single volumetric call in tube D-R30C78 did not require in-situ testing.

Because this volumetric indication could not definitely be associated with mechanical wear, STPNOC decided to plug the tube. In the STPNOC response to Generic Letter 97-05, STP informed the NRC that Eddy Current Testing (ECT) flaw sizing would only be used to leave tubes in-service for wear indications. All potential corrosion related degradation mechanisms are plugged on detection.

A final causal analysis report is expected in June 2016 - A copy of this report will be sent to the NRC.

-.,*'}::_*

Inspection Results - Foreign Object Wear - PLPs Enclosure NOC-AE-16003364 Page 7of14 Foreign object wear, while not affecting a large population of tubes, is an existing degradation mechanism at STP Unit 1.

A total of eight PLP indications were identified at the TTS, none of which were associated with a wear indication or visible wear. Table 2 lists the PLPs located near the TTS for 1RE19. There were no PLPs in SG 1 C. All of the TTS PLPs were associated with an object that had been noted as part of the FOSAR program, except for PLP-A-001. A video probe examination was performed near the reported location of PLP-A-001 and no object or wear was found.

Table 2: 1RE19 PLP Indications at the TTS SG PLP Row Col Leg Location Inch Visually Comments Verified A

PLP-A-001 59 59 HL TSH 0.12 Yes Nothing observed B

PLP-B-001 88 58 HL TSH 0.12 Yes 1RE19 Object 80003 B

PLP-B-002 87 59 HL TSH 0.09 Yes 1RE19 Object 80003 c

No PLPs 0

PLP-0-008 122 90 HL TSH 0

Yes 1RE19 Object 00021 0

PLP-0-009 122 94 HL TSH 0.07 Yes 1RE19 Object 00017 0

PLP-0-013 54 112 HL TSH 0.17 Yes

. 1RE19 Object 00042 0

PLP-0-014 57 113 HL TSH 0.09 Yes 1 RE 19 Object 00041 0

PLP-0-018 32 152 HL TSH 0.11 Yes 1RE19 Object 00004 A total of 25 PLP indications were identified at locations* above the TTS located in the vicinity of the flow distribution baffle (FOB). Table 3 lists the PLPs located near the FOB. All of the FOB PLPs were found in SG 10. None of these PLPs were associated with a wear indication. Each of the PLPs in Table 3 were present in the 1RE16 inspection. These PLP indications are due to remnants of a section of stabilizer wire that had entered steam generator 1 O prior to the 1RE12 outage. A +Point probe inspection of two tube locations surrounding each FOB PLP was conducted. There were no wear indications in any of these surrounding tubes.

SG D

D D

D D

D D

D D

D D

D D

D D

D D

D D

D D

D D

D D

Enclosure NOC-AE-16003364 Page 8of14 Table 3: 1RE19 PLP Indications at the FOB PLP Row Col Leg Location Inch PLP-D-001 78 36 HL FBH

-0.65 PLP-D-002 78 36 HL FBH 0.27 PLP-D-003 87 49 HL FBH

-0.55 PLP-D-004 110 56 HL FBH 1.06 PLP-D-005 111 57 HL FBH 2.16 PLP-D-006 126 78 HL FBH 0.93 PLP-D-007 108 90 HL FBH 0.76 PLP-D-010 102 98 HL FBH 1.19 PLP-D-011 75 111 HL FBH 0.71 PLP-D-012 75 111 HL FBH 1.12

. PLP-D-015

85. 119 HL FBH 0.51 PLP-D-016 76 134 HL FBH

-0.3 PLP-D-017 76 134 HL FBH 0.16 PLP-D-019 127 71 CL FBC 1.51 PLP-D-020 44 76 CL FBC

-0.61 PLP-D-021 44 76 CL FBC 0.28 PLP-D..;022 121 91 CL FBC

-0.38 PLP-D-023 121 91 CL FBC 0.48 PLP-D-024 50 100 CL FBC

-0.11 PLP-D-025 114 110 CL FBC 1.66 PLP-D-026 116 110 CL FBC 1.5 PLP~D-027 115 111 CL FBC 0.18 PLP-D-028 115 111 CL FBC 1.03 PLP-D-029 80 128 CL FBC

-0.26 PLP-D-030 31 151 CL FBC

-0.64 None of the PLP indications required in-situ proof of pressure or leakage testing to demonstrate tube integrity.

All instances of foreign object wear from prior cycles were inspected.in 1RE19. In each case, the object that caused the wear has been removed. None of the indications have changed since the 1RE16 inspection.

Inspection Results - TSP Wear Enclosure NOC-AE-16003364 Page 9of14 TSP wear is categorized as an existing degradation mechanism. During the STP Unit 1 SG inspections conducted during 1RE16, two tubes were found to have TSP wear. Location A-R126C88-06H had a reported indication of 6% TW at 1 RE16, as sized by bobbin. During 1RE19, this same location was sized by bobbin to be 5% TW. Location B-R3C155-06H had a reported indication of 9% TW at 1RE16, as sized by bobbin. At 1RE19, this location was sized by bobbin to be 9% TW.

There was one new location with a TSP wear indication reported for the first time in 1RE19. The indication at location D-R3C41-08C was sized by bobbin to be 10% TW. This tube was not tested in 1 RE16. A review of the 1RE13 data showed that this indication was 8% TW at that time. The probability of detection (POD) is low for an 8% TW indication.

All three of these TSP wear indications are located near the periphery or the no-tube lane of the tube buil'cffe." None of the TSP wear indications required in-situ testing or plugging:-*..

During the review of previous cycles' inspection results, STPNOC noted an error in the 1RE16 Inspection Summary Report. The 1RE16 report indicated that three TSP wear indications were observed. A review of the data during 1RE19 revealed that only two TSP wear indications were observed as described above.

Potential Degradation Mechanisms The Degradation Assessment categorized anti-vibration bar wear and tube-to-tube wear as potential degradation mechanisms. The results are as follows:

Mechanical Wear Indications at Anti-Vibration Bars There were no tubes in the STP Unit 1 SGs with indications of wear at the anti-vibration bars.

Mechanical Wear Indications due to Tube-to-Tube Contact There were no tubes in the STP Unit 1 SGs with indications of wear due to tube-to-tube contact.

A review of MBM and tube proximity measurement (PRO) indications, with follow-up inspection via +Point probe where applicable, did not indicate the presence of weaL Volumetric Indications Table 1, above, indicates that 13 VOL indications were identified in the 1RE19 inspection. They are attributed to the following mechanisms:

Three are associated with the three TSP wear indications. As discussed above, two of the TSP wear indications were identified in previous inspections and one was reported for the first time in 1RE19.

One is associated with the sludge pile volumetric indication in tube D-R30C78.

Nine are associated with foreign object wear from prior cycles. There was no change in these indications from 1RE16.

Non-Degradation Mechanisms Enclosure NOC-AE-16003364 Page 10of14 Indications first reported with potential flaw-like characteristics in the STP Unit 1 SGs may include indications initially reported as distortions or pre-existing signals such as manufacturing burnish marks or dents and dings (MBI, MBM, DNI, DNS), benign indications (DFI, DFS, OSI, DSS), anomalous signals at the tubesheet or elsewhere (DTI, DTS), non-quantifiable signals in the sludge pile region (NQI, NQS) and permeability indications (PVN).. The character of I-code signals, when observed, is determined by history review, Lead Analyst Review, or by +Point probe examination. All other I-code indications, other than the three TSP wear indications discussed above, were dispositioned as non-flaw conditions. There were no unresolved I-codes for 1RE19.

PVNs are technically not I-code signals but rather interferences that can compromise detection of flaw signals. There were no flaws associated with PVN indications.

MBMs are conditions where shallow volumetric scuffs were introduced into the tubes exterior during the final tube polishing. Of concern are new MBMs that exhibited increasing voltage as such a change may indicate a condition other than a manufacturing anomaly. No new MBMs were identified and no MBM increased by more than 0.5V.

There were 27 tubes with PRO indications (tubes in proximity) in the STP Unit 1 SGs. A review of historical data reveals that these proximity indications were present in previous inservice inspections. Follow-up inspection with +Point indicate that there were no flaw-like indications associated with any PRO indication.

Ding (ONG) is a baseline indication where the tubing inside diameter is less than normal. The dings are fabrication induced and not expected to grow in size. The Degradation Assessment specified that all dings greater than 5V that were reported in the baseline examination would be inspected with a +Point coil. 85 dings greater than 5V were identified in the STP Unit 1 SGs; these dings were inspected with a +Point probe and no degradation was found.

The 1RE16 inspection ONG indication at location B-R127C79 had a 47.94V bobbin signal at tubesheet cold (TSC) +3.21. The tube was dented when the SG was raised to a vertical position during installation when a wedge fell thru the downcomer, striking a peripheral tube. The wedge was removed during replacement of the SGs. The size of this ONG indication did not allow a standard size bobbin probe to pass. This location was inspected with a down sized probe during the 1RE19 inspection and no defect was found (NDF). This tube was administratively plugged in order to reduce future dose associated with probe change out.

Bulge (BLG) is a condition where the tubing outside diameter is greater than normal. An overexpansion (OXP) is a similar condition associated with anomalies in the tubesheet. There were no new BLG/OXP locations identified in 1RE19. Existing BLG/OXP locations were inspected with a +Point probe. The results of the tests were that no defects were found (NDF).

Plug Inspection Results All installed plugs were confirmed to be present and free from degradation.

,;i::

Bowl Inspection Results Enclosure NOC-AE-16003364 Page 11 of 14 A visual inspection of the SG channel head bowl was performed in all SGs during 1RE19, based on industry operating experience identified in the Degradation Assessment. Visual inspections of the SG hot leg and cold leg divider plate base, and with particular attention to the bottom 36 inch radius of the bowl, were performed in accordance with Westinghouse NSAL-12-01 using the SG manway channel head bowl cameras. Satisfactory inspection results were observed in all SGs. No degradation was observed.

Stud Hole Gauging Stud hole go/no-go gauging and stud gauging were performed on SG 1 C. All results were satisfactory. Stud holes and studs are gauged to identify thread wear that may occur. No defects were found.

Tube Repair Summary Two tubes were plugged in 1RE19. Tube D-R30C78 was plugged due to the conservative decision to treat the volumetric indication as a pit. As discussed above, only mechanical wear is left in-service based on indication sizing. Since wear could not definitively be determined to be the cause of the indication, the tube was plugged. Another tube, B-R127C79, was administratively plugged for an abnormally large dent which prevented inspection with a standard size bobbin probe. Table 4 lists the total tubes plugged for each Unit 1 SG.

Table 4: Total Tubes Plugged Per Steam Generator Steam Generator Total Tubes Plugged SG Percent Plugged 1A 33 0.435 18 41 0.541 1C 26 0.343 1D 14 0.185 Summary of Secondary Side Inspection and Maintenance Plan The following is a summary of the secondary side inspection and maintenance plan:

TTS FOSAR in all four SGs generators including annulus and no-tube lane TTS in-bundle FOSAR as follows:

SG 1A inspect every fourth column both hot leg and cold leg SG 1 B inspect every fourth column both hot leg and cold leg SG 1 C inspect every fourth column both hot leg and cold leg SG 1 D inspect every 2nd column both hot leg and cold leg Ultra-sludge lancing on all four SGs Steam Drum inspections in SG 1 C and SG 1 D Upper Steam Drum inspection in SG 1 C Video probe inspection of 9th support plate on SG 1A FOSAR of all foreign objects left in service during 1 RE16, if reachable by tooling

,,. 's r,-~('C.' ;;*.'*:*: '

  • FOSAR of all PLPs identified by eddy current inspection, if reachable by tooling

Secondary Side Inspection and Maintenance Results Sludge Lancing Enclosure NOC-AE-16003364 Page 12of14 All four STP Unit 1 SGs were sludge lanced. Table 5 provides a summary of the mass of sludge collected from sludge lancing operations.

Table 5: Mass of Sludge Collected During 1RE19 Steam Generator 1RE19 Sludge Weight (lbs}

1 A - Tubesheet 22.2 1 B - Tubesheet 45.6 1 C - Tubesheet 52.2 1 D - Tubesheet 19.5 Post-lance inspections revealed that the top of the tubesheet of all four SGs are generally clean with essentially all sludge removed. No anomalies were noted on any tubesheet location. The kidney region, encompassing the tubes within approximately rows 19-35 from columns 72-84, has hardened collars at the TTS, all less than 1.125 inches in thickness. The hardened sludge pile has not grown measurably since 1RE16.

Steam Drum STP performed visual observations of the steam drums for SG 1 C and SG 1 D to assess the condition of the steam drum and to ensure reliable operations until the next inspection period.

The steam drums were inspected for erosion, mechanical damage, cracked welds, corrosion, foreign material and any unusual conditions. The upper steam drum was also inspected in SG 1C.

The steam drum inspections revealed no abnormal conditions - No defects were found.

ln-.Bundle Inspection of the Ninth Tube Support Plate STP performed an in-bundle inspection of the ninth TSP of SG 1 A in order to obtain Visual information on the deposit loading in the upper region of the tube bundle. Video probes were deployed from the tube lane using extensions that permitted visual observation of flow slots, tube surfaces, and trefoil ligaments.

The inspection showed a thin layer of magnetite covering the TSP top surface, along with some loose deposits but not to any significant extent. Scale provided a continuous cover of all the tube surfaces with the exception of tubes nearest the no-tube lane. The tubes near the no-tube lane are minimally fouled. No deposit bridging across the trefoil to tube outside diameter (OD) surface nor departures from the expected appearance of the TSP ligaments were observed.

Foreign Object Mapping and Retrieval Enclosure NOC-AE-'16003364 Page 13of14 FOSAR was performed at the top of the tubesheet, the tube bundle-shell annulus and the tube lane in all four SGs. A total of 81 foreign objects were identified during the top of tubesheet video probe inspections. During the eddy current program, eight PLP calls were reported. As required by EPRI guidelines, coordination between the eddy current and secondary visual inspection results was maintained. Top of the tubesheet tube locations showing PLP signals by eddy current were visually-inspected to identify the source of the signal. In addition, all top of the tubesheet tube locations where foreign objects were identified during visual inspections were included in the top of tubesheet +Point probe inspection program.

There was one Priority 1 object that was not retrievable during the 1RE16 inspection (object 10039, located at D-R120C68-HL). Object 10039 was not retrievable because one end was fixed in place in sludge on the top of the tubesheet. This object was evaluated and it was determined that the tubes adjacent to 10039 could remain in service without exceeding structural and leakage integrity criteria for the operating interval of Unit 1 Cycles 17 through 19.

An inspection of this area in 1RE19 showed that the sludge was no longer on the tubesheet and the wire object was no longer present. Wear was not visible, nor was wear detected by ECT. It is likely that the object was sludge lanced out of the SG.

Based on existing wear analyses and top of the tubesheet velocity maps, prioritization criteria were developed and used to assign priorities to each of the identified foreign objects. Foreign objects were assigned priorities based on the characteristics of the object and its location on the tubesheet:

Priority 1 foreign objects are those which cannot be left in the SGs and justify a three-cycle operational assessment without further evaluation or additional remedial measures.

Priority 2 foreign objects can be left in arid operate for three cycles, but still have the potential for wear and will need to be addressed in future inspection outages.

Priority 3 foreign objects cannot cause wear of any significance and may be left in the steam generator indefinitely.

Priority 1 and Priority 2 objects, whether they were retrieved or not, were tested and bound by a

+Point probe to provide assurance that they had not caused wear, in accordance with the EPRI Integrity Assessment Guidelines.

There were 36 objects that could not be removed from the SGs. This includes 21 Priority 3 objects, 15 Priority 2 objects and zero Priority 1 objects. Each identified foreign object not removed from the respective SG was subjected to a foreign object wear analysis to support the planned operating period through Cycle 22.

Condition Monitoring Conclusion Enclosure NOC-AE-16003364 Page 14of14 Based on the Condition Monitoring evaluation, inservice inspection of tubes in service during Cycle 19 confirms that they all meet the structural integrity requirements of Steam Generator Integrity Assessment Guidelines, Revision 3. Ne.ither the small volumetric.indication discovered in SG 1 D nor the minor tube support plate wear on tube D-R3C41-08C challenge structural integrity limits. Since no degradation mechanisms challenging structural integrity limits were detected during the 1RE19 inspection and no primary-to-secondary leakage was observed prior to the end of Cycle 19, the condition monitoring assessment requirements for SG operation for Cycles 17, 18, and 19 are satisfied. With no significant indications of tube degradation, in-situ tests were not required. No tubes were pulled during 1RE19. No challenges to the SG Performance Criteria were identified; therefore, the condition monitoring requirements for the Unit 1 replacement steam generator tube bundles at the end of Cycle 19 are satisfied. The next Unit 1 SG inspection is scheduled for refueling outage 1 RE22.