- NW MI
~a'S*~f^~SOO*
NWMI-201 6-RAI-001 Rev. 0 Appendix G -
EDF-3124-0003, Preliminary Maximum Hypothetical Accident to Support the Northwest Medical Isotope Facility Environmental Report G-i
Document ID:
EDF-3124-0003 Revision ID: 2 Effective Date: 1/21/16 Engineering Design File Preliminary Maximum Hypothetical Accident to Support the Northwest Medical Isotopes Facility Environmental Report Portage Project No.: 3124 Project
Title:
NWMI Environmental Report 4Portage TEM-9002 09/29/09 Rev. 0
TEM-9002 09129109 Rev. 0
- 1. Portage Project No.:
3124 ENGINEERING DESIGN FILE EDF-3124-0003 Rev. 2 Page 1 of 59
- 2. Proj ect/Task:
NWMI Environmental Report
- 3. DCN#
4.
Title:
Preliminary Maximum Hypothetical Accident to Support the Northwest Medical Isotopes Facility Environmental Report
- 5. NPHI PC or SDC: N/A
- 6. SSC Safety Category: N/A 7
Sunumary: The Radiological Safety Analysis Computer (RSAC) code, Version 6.2, was used to develop the preliminary maximum hypothetical accident (MHilA) for the Northwest Medical Isotopes, LLC (NWMVII Radioisotope Production Facility (RPF). The worst-case accident is considered preliminary and is based on the RPF preliminary hazards analysis (NWMvI-2015-SAFETY 001) and NWMI's preliminary design for the RPF prepared in support of the Construction Penmit Application submitted in 2015.
The MH-A consists of a fitre-related gross failure of the target dissolution offgas treatment system that releases all radioiodine and noble gas radioisotopes retained in that system out the RPF stack without mitigation.
The inventory for the MHA is based on a set of initial conditions that were designed to maximize the potential source term and bound the credible scenanios.
The results of the modeling show that for a 22.9 m (75-ift) stack with the release detailed above, the maximum dose received during a two-hour exposure by an individual would be a total effective dose equivalent (TEDE) of --22.6 remn (as compared to 17.1 remn in Chapter 19) at a distance of 1,100 in. The TEDE to the public located outside at the controlled area would be from 3.6 mSv (0.36 rem) at the nearest fence line 10 m (30 if) to 7 mSv (0.70 remn) at the furthest fence line 91 m (300 if). The TEDE to the nearest resident located 430 m away was calculated to be 31 mSv (3.1 rem). The highest TEDE to the licensee staff outside the building would be 7 mSv (0.70 rem) for a person located 91 m (300 if) from the location of the stack. The TEDE doses are greater than the limits of 10 CFR 20, "Standards for Protection Against Radiation." However, 10 CRF 20 limits are for normal operations not accident situations. The TEDE indicates that the maximum hypothetical accident (MiHA) is the intermediate consequence event per 10 CFR 70.61, "Performance Requirements."
8 Distribution: (Portage, Inc.)
9 Review (Rk) and Approval (A) Signatutres:
(Identify minimum reviews and approvals. 'Additional reviews/approvals may be added.)
~~Printed Name/
RIA Organization Signature..
Date..:,
Author/Design Agent A
Dave Thome
- 1/21/16 Independent Review R
Michel Hall
]7*
1/21/16 Independent Review R
,Project Manager R/A John Beller
- 1/21/16 Registered Professional Engineer's Stamp (if required)
[] N/A
TEM-9002 ENGINEERING DESIGN FIlE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 2 of 59 Contents
- 1.
Introduction................................................................................................... 4
- 2.
Radiological Safety Analysis Computer Overview..............
- ......................................... 4
- 3.
Dissolution Offgas System.................................................................................. 5
- 4.
Maximum Hypothetical Accident Scenario and Source Term........................................... 7
- 5.
Model Parameters and Assumptions....................................................................... 8
- 6.
Model Results................................................................................................ 8
- 7.
References................................................................................................... 11 Attachment - RSAC Output.................................................................................... 12 Figures Figure 1.
Target Dissolution Flow Diagram............................................................... 5 Figure 2.
Iodine Removal System.......................................................................... 6 Figure 3.
Total Effective Dose Equivalent (Inhalation plus External) for 2-Hour Ground Level Exposure from Maximum Hypothetical Accident.................................... 10 Tables Table 1.
Iodine Removal Units Source Terms for the Maximum Hypothetical Accident............ 7 Table 2.
Maximum Hypothetical Accident Inhalation Committed Effective Dose Equivalent......................................................................................... 9 Table 3.
Maximum Hypothetical Accident External Cloud Gamma Dose............................ 9 Table 4.
Maximum Hypothetical Accident Total Effective Dose Equivalent........................ 10
TEM-9002 09129/09 Rev. 0
.ENGINEERING DESIGN FILE EDF-31 24-0003 Rev. 2 Page 3 of 59 This page intentionally left blank.
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 4 of 59
- 1.
INTRODUCTION The Radiological Safety Analysis Computer (RSAC) code, Version 6.2 (RSAC-6.2), was used to ensure that the doses to the public detennine if the dose rate requirements in Title 10, Code of Federal Regulations, Subpart 100.11 (10 CFR 100.11), "Determination of Exclusion Area, Low Population Zone, and Population Center Distance," would drive the required size of the exclusion area boundary for the Northwest Medical Isotopes, LLC (NWMvI) Radioisotope Production Facility (RPF). 10 CFR 100.11 requires that an exclusion area be sized so that an individual located at any point on its boundary for 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> immediately following onset of the postulated fission product release would not receive a total radiation dose to the whole body in excess of 25 rem roentgen equivalent in man (rem). The worst-case accident is considered preliminary and is based on the RPF Preliminary Hazards Analysis(NWMI-20 15-SAFETY-00 1), and facility preliminary design completed in support of the Construction Permit Application submitted to the U.S. Nuclear Regulatory Commission (NRC) (NWMVI-2013-021, Rev. 0).
The preliminary worst-case accident is identified to be a release of the accumulated radionuclides in the offgas system that results in the loss of the fission gas retention system. The associated preliminary analysis was completed to determine the bounding dose to an individual given in total effective dose equivalent (TEDE) at various distances from the release point.
RSAC-6.2 was developed in 1973 by Idaho National Laboratory and is still used today for modeling complex accidents and radiological consequences to individuals from the release of radionuclides to the atmosphere. A user can generate a fission product inventory; decay and ingrowth of the inventory during transport through processes, facilities, and the environment; model the downwind dispersion of the activity; and calculate doses to downwind individuals (INL/EXT-05 -00642, RSAC 6.2 with WinRP 2.0:
User Manual). Doses are calculated through the inhalation and cloud gamma exposure pathways.
- 2.
RADIOLOGICAL SAFETY ANALYSIS COMPUTER OVERVIEW A fission product inventory can be calculated in RSAC from the reactor operating history or to simulate a nuclear criticality accident. Radionuclide inventories can also be directly input into RSAC. Source term modeling allows for complete progeny ingrowth and decay during all accident phases. Release scenario modeling allows fractionation of the inventory by chemical group or element. The effects of high-efficiency particulate air (HIEPA) filters or other cleanup systems can be modeled. RSAC calculates meteorological dispersion in the atmosphere using Gaussian plume diffusion for the Pasquill-Gifford, Hilmeier-Gifford, and Markee models. A unique capability is the ability to model Class F fumigation conditions, the meteorological condition that causes the highest ground level concentrations from an elevated release.
Doses may be calculated for various pathways, including inhalation, ingestion, ground-surface, air immersion, and water immersion pathways. Dose calculations may be made for either acute or chronic releases. RSAC-6.2 calculates inhalation doses using the International Commission on Radiation Protection (ICRP) Publication 30, Limits for Intakes of Radionuc lides by Workers (1979) model, with dose conversion factors (DCF) from EPA-520 1/1-88-020, Limiting Values of Radionuc lide Intake and Air Concentration and Dose Conversion Factors for Inhalation, Submersion, and Ingestion. The committed dose equivalent (CDE) is calculated for individual organs and tissues over a 50-year period after inhalation. The CDE for each organ or tissue is multiplied by the appropriate ICRP Publication 26, Recommendations of the ICRP (1977) weighting factor and then summed to calculate the committed effective dose equivalent (CEDE).
The RSAC-6.2 gamma dose from the cloud (in which the person may or may not be immersed in the cloud depending on the plume position in relation to the ground surface) is the effective dose equivalent (EDE), which is the sum of the products of the dose equivalent to the organ or tissue and the weighting factors applicable to each of the body organs or tissues that are irradiated.
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09/29109 Rev. 2 Rev. 0 Page 5 of 59 The sunmnation of the two RSAC-6.2 doses is the total effective dose equivalent (TEDE), which is the sum of the EDE (for external exposures) and the CEDE (for inhalation exposures). The RSAC-6.2 dose calculations and dose terminology are consistent with NRC 10 CFR 20, "Standards for Protection Against Radiation" terminology, based on ICRP Publications 26 and 30.
- 3.
DISSOLUTION OFFGAS SYSTEM Target disassembly and dissolution of irradiated LEU target results in gaseous fission products (iodine [1],
xenon [Xe], and krypton [Kr]) with very high radiation levels. A primary function of the process offgas systems is to control release of these gases both within the facility and external to the facility. The dissolver offgas treatment system is divided into the nitrogen oxide (NOx) treatment and fission gas retention subsystems. The fission gas retention system removes isotopes of iodine from the offgas and retains noble gases (Xe and Kr) until they have decayed sufficiently to allow release. The primary function of the NOx treatment system is to treat the dissolver offgas so that it is suitable for discharge to the fission gas retention system.
The primary functions of the fission gas retention system are to remove the isotopes of iodine from the gas stream and to delay release of the noble gases (Xe and Kr) sufficiently to allow release to the stack.
The fission gas retention system also provides primary confinement of the gases to prevent their release within the facility. Figure 1 illustrates the target dissolution process.
[Proprietary Information]
Figure 1. Target Dissolution Flow Diagram Within the fission gas retention system, the iodine removal units ([RU) and the secondary absorbers are the primary unit operations responsible for retaining the iodine and fission product noble gases. The primary absorbers allows decay time for the short half-life noble gases to reduce the dose at the secondary treatment equipment. The system uses three parallel IRUs, as shown in Figure 2: one IIRU is for the target disassembly station, one for the dissolvers, and the third is an installed spare.
TEM-9002 09/29109 Rev. 0 ENGINEERING DESIGN FILE EDF-3124-0003 Rev. 2 Page 6 of 59
[Proprietary Information]
Figure 2.Iodine Removal System
TEM-9002 09129109 Rev. 0 ENGINEERING DESIGN FILE EDF-31 24-00 03 Rev. 2 Page 7 of 59
- 4.
MAXIMUM HYPOTHETICAL ACCIDENT SCENARIO AND SOURCE TERM The maximum hypothetical accident (MHA) consists of a fire-related gross failure of the target dissolution offgas treatment system that releases all radioiodine and noble gas radioisotopes retained in that system out the RPF stack without mitigation.
The evaluation of the inventory for the considered MVHA is based on a set of limiting initial conditions that were designed to maximize the potential source term and bound the credible scenarios. These assumptions include:
[Proprietary Information]
All iodine and noble gases in the targets released into the offgas system, and no iodine or noble gases captured in the nitrogen oxide (NOx) scrubbers or retained in the dissolver solution
[Proprietary Information]
Greater than expected release of material (e.g., the entire inventory of iodine is assumed to be deposited on a single IRU, no plating out of iodine, or subsequent capture downstream oflIRU)
The source term used in the MHIA is from NWMI-2013-CALC-01 1, Source Term Calculations. The breakdown of the radionuclide inventory used in NWMVI-2013-CALC-01 1 is extracted from NWMVI-2013-CALC-006, Overall Summary Material Balance - MURR Target Batch, using the reduced set of 123 radioisotopes. NWMI-2013-CALC-0 14, Selection of Dominant Target Isotopes for NWM[
Material Balances, identifies the 123 dominant radioisotopes included in the MUJRR material balance (NWMI-2013-CALC-006). NWMvI-2013-CALC-014 provides the basis for using the 123 radioisotopes from the total list of 660 radioisotopes potentially present in irradiated targets. The majority of omitted radioisotopes exist in trace quantities and/or decay swiftly to stable nuclides. The reduced set of 123 radioisotopes consists of those that dominate the radioactivity and decay heat of irradiated targets.
The bounding iodine and noble gas isotopic source terms used were taken from NWMIH-20 13 -CALC-0 11 and are summarized in Table 1.
Table 1. Iodine Removal Units Source Terms for the Maximum Hypothetical Accident 1291 1301
-132j 133I 133m I 134I Total curies =
3.67E-05 9.06E-0 1 1.70E+04 2.54E+04 3.32E+04
.,5.50E+00 3.39E+02 1.i72E+04/
',9.32E+04 83m*
8 5Kr 87Kr
- 9.65E+02 2.98E+01 2.12E+02
.131mXe 1 33rXe 135Xe 1.84E+02 4.03E+04 1.-1*l]9E+03)_
3.02E+04 2:
'.8 fE+03-6.75E44031 7.46E+04
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 8 of 59
- 5.
MODEL PARAMETERS AND ASSUMPTIONS The Radiological Safety Analysis Code (RSAC) system, RSAC Version 6.2, was used to model the dispersion resulting from the MH-A. The following common parameters were used for all model runs:
Release point: 22.9 meters (in) (75 feet [it])
Wind-speed: 2 m/second (s) (provides minimal mixing and dilution, considered conservative)
Source term per Table 1 Analysis of Class F stability characteristics (stable air, considered conservative)
No plume rise (i.e., buoyancy or stack momentum effects) accounted for in this model (limited mixing and dilution, conservative)
Mixing depth: 400 m used in the model (RSAC default)
Air density: 1,240 grams (g)/cubic meter (in3) used in the model Pasquill-Gifford Sigma values used in the model No plume depletion used (i.e., wet or dry deposition) 2-hr release assumed (i.e., constant release of all activity over this time period) 2-hr exposure assumed ICRP 30 model used for inhalation doses Finite cloud immersion model assumed Breathing rate: 3.47E-4 m3/s (i.e., ICRP 30 heavy activity value)
Respiratory fraction: 1 provides the RSAC output file for the MHA analyses.
- 6.
MODEL RESULTS The dose results for the MiHA inventory are provided in Table 2 through Table 4, and are illustrated in Figure 3. The results of the modeling show that for a 22.9 m (75-ft) stack with the release detailed above, the maximum dose received during a two-hour exposure by an individual would be a total effective dose equivalent (TEDE) of -22.6 rem (as compared to 17.1 rem in Chapter 19) at a distance of 1,100 m. The TEDE to the public located outside at the controlled area would be from 3.6 mSv (0.36 rem) at the nearest fence line 10 m (30 ft) to 7 mSv (0.70 rem) at the furthest fence line 91 m (300 fi). The TEDE to the nearest resident located 430 m away was calculated to be 31 mnSv (3.1 rem). The highest TEDE to the licensee staff outside the building would be 7 mSv (0.70 rem) for a person located 91 m (300 ft) from the location of the stack. The TEDE doses are greater than the limits of 10 CFR 20, "Standards for Protection Against Radiation." However, 10 CRF 20 limits are for normal operations not accident situations. The TEDE indicates that the maximum hypothetical accident (MHA) is the intermediate consequence event per 10 CFR 70.61, "Performance Requirements."
The calculated dose rates meet the 10 CFR 50.34, "Contents of Applications; Technical Information,"
requirements to ensure that (1) an individual located at any point on the boundary of the exclusion area for any 2-hr period following the onset of the postulated fission product release, would not receive a radiation dose in excess of 25 rem TEDE, and (2) an individual located at any point on the outer boundary of the low population zone, who is exposed to the radioactive cloud resulting from the postulated fission product release (during the entire period of its passage) would not receive a radiation dose in excess of 25 rem TEDE. The calculated dose rates for the MHA show that the MIHA is an intermediate consequence event per 10 CFR 70.61, "Performance Requirements."
TEM-9002 09129109 Rev. 0 ENGINEERING DESIGN FILE EDF-3124-0003 Rev. 2 Page 9 of 59 Table 2. Maximum Hypothetical Accident Inhalation Conmmitted Effective Dose Equivalent 100 200 300
- 4 3 0 b 500 7O00 800 900 1,100 1,100 1.500
- 1, 0.00E+00 1.38E-19
, 9.03E-05 S 1. 12E-0 1 2.49E+00 5.37E+00
-, : i 2" i'i'1.O2E+01i.
1.47E+01
- .............*80E+O1 2.02E+0 1 S2.2 1E+0 1
'/2.2,1E+01",
2.16E+01
~.
209E+0 1 2.02E+0 1
- ' 0.O0E+00.,
3.15E-23
- ,_2.07E-08[ [
2
...258E-05..
3,,, _5.79E-04,,,
1.25E-03 3.47E-03 4.28E-03 4.82E-03 5.1i::ii7E-03.:*~ii 5
5.32E-03
!.,532E-03:*::
5.23E-03 3:. 5:.09E-03 _
- 4.92E-03 0
,,.00E+-00 8.1 9E-3 1
... 5.42E-.16 S 6.80E-13
- ' 1.54E-11 S 3.35E-11
- 6/[.
[648E-11(
9.41E-11
- ,21.!17E-1!0_
1 1.33E-10 1?"
.......44....
1.49E-10 1II:.50E-l10 S 1.49E-10 1
].....46E-10 1.42E-10
, O.OOE+OO 1.3 8E-1 9
- ... 9.03E-05 1
.....12E-01
- ' 2.49E+00 5.37E+00
' 1.02E+*011 1.47E+01 1
...!80E+01.
S 2.02E+0 1 2.21E+01
',2;2'1E+.01 2.16E+01 2.20_9E+/-.01 2.02E+0 1 aDose at the nearest fence line, which is 10 nm b Nearest resident is located at 430 m.
Table 3. Maximum Hypothetical Accident External Cloud Gamma Dose I.
-]
- 200, 300 500 700
.. 7'800:
900 1,100
,1,300 1:i
,4007 1,500 3.1.0E-_01 i.88E]3-02,'
5.96E-01 3.60E-02
-7...5.75E-01 3.48E-02'-!
5.46E-01 3.31IE-02
-,+ 5.19E-0,1,,7-3.15E-02, 5.09E-01 3.09E-02 4.70E-01 2.86E-02
..4.48E-0_1......... 2.73E-O2...
4.26E-01 2.60E-02
.i.!
-, i-!i~ i 4. 09E-01 i*:"ii, :,.2.5.0E-052,,i[
3.92E-01 2.40E-02
" : ::....3.76E-0i1..... '... 2i30E-02,'
- 3.60E-01 2.21E-02
- 3. 45E-01..
2....
12_
E-02.
3.31E-01 2.03E-02
- 3.
339E-02_ -
6.54E-02 5.97E-02 5.65E-02 S 5.53E-02
- ,!:, -5.34E-02 '
S 5.12E-02
- -4.88E-02 4.65E-02 S 4.28E-02 S 3.94E-02 S 3.63E-02 3:63E-01 6.97E-01 6--
6.73E3 6.3 9E-0 1 6
.:607E-01 S 5.95E-01 i-i_' 57.74Et-E0i 5.50E-01 5.24E-01 4.99E-0 1 4.59E-0 1 4.22E-0 1
.-.' i04E-01....
3.88E-01
- 1 aDose at the nearest fence line, which is 10 1n.
b Nearest resident is located at 430 m.
TEM-9002 09129/09 Rev. 0 ENGINEERING DESIGN FILE EDF-31 24-0003 Rev. 2 Page 10 of 59 Table 4. Maximum Hypothetical Accident Total Effective Dose Equivalent j~a Is 100 300 500 600 700
(,, '"
, *800,
900 1,000;?
- oo 1,100 1
,200 1,300 b.,
- - 1,400 1,500
-*: 3.10E 5.96E-01 S 6.58E=01 5.88E+00 1.52E+01
! 2.06E+0 1 2.25E+01
,"2.25E+0 1 S 2.20E+0 1 S 2.05E+01 1..188E-02,
- 3.
039E-02, 3.60E-02 6.54E-02 3.48E02 6.0E-0 3.3 1E-02 5.97E-02 3.22E-02 5.53E-02
" -.. 3.23E-02'
...... '5.34E-02" S 3.21E-02 5.12E-02 3.08E-02 4.65E-02
,,,.02E-02
- 4.47E-02.
2.93E-02 4.28E=02
,....2:83EO2-0 4.11IE-02 2.73E-02 3.94E=02 2,
...,°263E-02 3"I}....379E--02...
2.52E--02 3.63E=02
",3.63E=01 S 6.97E-01 S 7.51E-01 3.:'
1:>ioE+600, 5.97E+00 S...1.08E+01-1.53E+01 2.07E+01 2.26E+01 2.20E+0 1
, 2.06E+01 a Dose at the nearest fence line, which is 10 in.
b Nearest resident is located at 430 m.
Figure 3 provides a graph of the model results based on the parameters described above. The stack provides the time and distance to disperse the plume prior to reaching the ground. The results show that a person within close proximity to the facility would receive almost no dose.
25 EP 20 15
- 0. 10 o
w-L.
0 0
200 400 600 800 1000 1200 1400 1600 Distance from Stack, meters Figure 3.Total Effective Dose Equivalent (Inhalation plus. External) for 2-Hour Ground Level Exposure from Maximum Hypothetical Accident
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 11 of 59
- 7.
REFERENCES 10 CFR 20, "Standards for Protection Against Radiation," Code of Federal Regulations, as amended.
10 CFR 50.34, "Contents of Applications; Technical Information," Code of Federal Regulations, as amended.
10 CFR 70.61, "Performance Requirements," Code of Federal Regulations, as amended.
10 CFR 100.11, "'Determination of Exclusion Area, Low Population Zone, and Population Center Distance," Code of Federal Regulations, as amended.
EPA-5201/1-88-020, Limiting Values of Radionuclide Intake and Air Concentration and Dose Conversion Factors for Inhalation, Submersion, and Ingestion, Federal Guidance Report No. 11, U.S. Environmental Protection Agency, Washington, D.C., 1988.
ICRP Publication 26, Recommendations of the ICRP, International Commission on Radiological Protection, Ottawa, Ontario, Canada, 1977.
ICRP Publication 30, Limits for Intakes of Radionuclides by Workers, Part 1, International Commission on Radiological Protection, Ottawa, Ontario, Canada, 1979.
INL/EXT-05-00642, RSAC 6.2 with WinRP 2.0: User Manual, Idaho National Laboratory, Idaho Fails, Idaho, 2005.
NWMI-2013-CALC-006, Overall Summary Material Balance - MURR Target Batch, Rev A, Northwest Medical Isotopes, LLC, Corvallis, Oregon, 2013.
NWMI-20 13-CALC-0 11, Source Term Calculations, Rev A, Northwest Medical Isotopes, LLC, Corvallis, Oregon, 2015.
NWMI-2014-CALC-0 14, Selection of Dominant Target Isotopes for NWMJ Material Balances, Rev A, Northwest Medical Isotopes, LLC, Corvallis, Oregon, 2014.
NWMVI-2015-SAFETY-001, Radioisotope Production Facility Preliminary Hazards Analysis, Rev. A, Northwest Medical Isotopes, LLC, Corvallis, Oregon, 2015.
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-O003 09129109 Rev. 2 Rev. 0 Page 12 of 59 Radiological Safety Analysis Computer Code Output RSAC-6TINPUT 20160121 08:09 o
1 2
3 4
5 6
7 123456789012345678901234567890123456789012345678901234567890 1234567890123456789
- Iodine MH-A Inventory 2000,0
- Line replaced by WinRp to use temporary external file srcl.txt
- 2002,C:\\Users\\dthomne\\Documents\\,Rsac\\Input Files\\Iodine_2016.txt 2002,srcl.txt 2999
- F Stability and 2 rn/s 5000,0 5001,2.,22.86,400., 1240.,0.,0 5101, 10.,100.,200.,300.,430.,500.,600.,700.
5201, 1.389E-4,0.
5400,2,0.,0.,0 5410,3,6,0 5999
- Dose Data 7000,0,-2, 1,0,1 7001,3.47E-04,0.,0,0, 1.
7999
- Cloud Gamma 9000,0,0.
10000 0
1 2
3 4
5 6
7 123456789012345678901234567890123456789012345678901234567890 1234567890123456789
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 13 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:09 PAGE 1
- Iodine MIIA Analysis
- **DIRE~CT RADIONUJCLLDE INPUT ANY PREVIOUS INVENTORY HAS BEEN ZEROED NUCLIDE HALF LIFE CUIRIES 531290 1129 1.570E+07 yr 3.670E-05 531300 I130 1.236E+01 hi 9.060E-01 531310 1131 8.021E+00 d 1.700E+04 531320 1132 2.295E+00 h 2.540E+04 531330 1133 2.080E+01 h 3.320E+04 531331 1133m 9.000E+00 s 5.500E+00 531340 1134 5.250E+01 m 3.390E+02 531350 1135 6.570E+00 h 1.720E+04
- METEOROLOGICAL DATA MEAN WIND SPEED =2.000E+00 (nm/s)
STACK HEIGHT -- 2.286E+01 (in)
MIX[NG LAYER HEIGHT -- 4.000E+02 (in)
AIR DENSITY = 1.240E+03 (g/cu mn)
WET DEPOSITION SCAVENGING COEFFICIENT =0.000E+00 (1/S)
NO CORRECTION IS BEING MADE FOR PLUME DEPLETION BY FALLOUT DEFAULT DRY DEPOSITION VELOCITIES (m/s)
SOLIDS = 0.000E+0-0 HALOGENS = 0.000E+00 NOBLE GASES = 0.000E+00 CESIUM = 0.000E+00 RUTHENIUM =0.000E+00 THERE IS 1 SET OF LEAKAGE CONSTANTS (K1,K2) 1.389E-04 0.000E+-00 PASQUILL CLASS F METEOROLOGY, P-G SIGMA VALUES WARNING - DIFFUSION FOR DISTANCES OF LESS THAN 100 METERS IS EXTRAPOLATED ENHANCED DEPOSITION PARAMETERS PARTICLE DIAMETER = 0.000E+00 (mn) PARTICLE DENSITY -- 0.000E+00 (g/cm3)
DOWNWIND DISTANCE STACK SIGY SIGZ CHI/Q HEIGHT (in)
(mn)
(in)
(s/cu in) 1.000E+01 2.286E+01 5.776E-01 3.454E-01 0.000E+00
TEM-9002 09/29109 Rev. 0 ENGINEERING DESIGN FILE ED F-3124-0003 Rev. 2 Page 14 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/ll/02) SERIAL 1 DATE 20160120 TIME 08:09 PAGE 2
- Iodine MLIA Analysis DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) l.000E+f02 2.286E+01 4.621E+00 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 2.000E+02 2.286E+01 8.642E+00 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 3.000E+02 2.286E+01 1.246E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 4.300E+02 2.286E+01 1.725E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 5.000E+02 2.286E+01 I.977E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 6.000E+02 2.286E+01l 2.331E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 7.000E+-02 2.286E+01 2.679E+01 SIGY SIGZ CHIIQ (s/cu mn) 2.247E+00 5.171E-25 SIGY SIGZ CHI/Q (s/cu mn) 3.988E+00 3.376E-10 SIGY SIGZ CIII/Q (s/cu m) 5.506E+I00 4. 185E-07 SIGY SIGZ CHI/Q (s/cu in) 7.293E+00 9.302E-06 SIGY SIGZ CHI/Q (s/cu in) 8.195E+O0 2.008E-05 SIGY SIGZ CHI/Q (s/cu in) 9.430E+00 3.834E-05 SIGY SIGZ CHI/Q (s/cu in) 1.061lE+0 1 5.500E-05
- INHALATION DOSE EQUIVALENT CALCULATION USING DOSE CONVERSION FACTORS FROM FEDERAL GUIDANCE REPORT 11 RESPIRABLE FRACTION = 1.000E+-00 BREATHING RATE = 3.470E-04 (cu m/s)
RELEASE TIME FOR EXPONENTIAL DECAY FUNCTION = 7. 199E+03 (s)
INTERNAL EXPOSURE TIME PERIOD = 5.000E+0 1 (yr)
PARTICLE SIZE =1.0 MICRON AMAD LUNG DEPOSITION FRACTIONS: N-P = 0.300 T-B = 0.080 P = 0.250 DEFAULT ELEMENT LUNG CLEARANCE CLASSES SELECTED TO GIVE MAXIMUM DOSE
TEM-9002 ENGINEERING DESIGN FILE EDF-3124--0003 09129109 Rev. 2 Rev. 0 Page 15 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:09 PAGE 3
- Iodine MBA Analysis DOWNWIND DISTANCE = 1.000E+01 (in)
PLUME TRAVEL TIME = 5.000E+00 (s)
CHIIQ = 0.000E+00 (s/cu mn)
DOWNWIND DISTANCE = 1.000E+02 (in)
PLUME TRAVEL TIME = 5.000E+01 (s)
CHI/IQ= 5.171E-25 (s/cu mn)
DOWNWIND DISTANCE = 2.000E+02 (in)
PLUME TRAVEL TIME = 1.000E+02 (s)
CHIIQ = 3.376E-10 (s/cu in)
DOWNWIND DISTANCE = 3.000E+02 (in)
PLUME TRAVEL TIME = 1.500E+02 (s)
CHI/Q = 4. 185E-07 (s/cu in)
DOWNWIND DISTANCE = 4.300E+02 (in)
PLUME TRAVEL TIME = 2. 150E+02 (s)
CHI/IQ =9.3 02E-06 (s/cu in)
DOWNWIND DISTANCE = 5.000E+02 (in)
PLUME TRAVEL TIME = 2.500E+I02 (s)
CHIIQ = 2.008E-05 (s/cu in)
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 16 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:09 PAGE 4
- Iodine MHA Analysis DOWNWIND DISTANCE =6.000E+02 (in)
PLUME TRAVEL TIME = 3.000E+02 (s)
CI{IQ = 3.834E-05 (s/cu mn)
DOWNWIND DISTANCE = 7.000E+02 (in)
PLUME TRAVEL TIME = 3.500E+02 (s)
CHI/Q = 5.500E-05 (s/cu m)
INHALATION COMIMYFITE DOSE EQUIVALENTS ORDERED BY ORGAN (rem)
DOWNWIND DISTANCES (in)
ORGAN NO. 1.00E+01 1.00E+02 2.00E+02 3.00E+02 4.30E+02 5.00E+02 6.00E+02 7.00E+-02 LUNGS 1 0.00E+00 3.28E-20 2.14E-05 2.65E-02 5.89E-01 1.27E+00 2.42E+00 3.47E+I00 S WALL 2 0.00E+00 5.36E-21 3.50E-06 4.33E-03 9.60E-02 2.07E-01 3.95E-01 5.65E-01 SI WALL 3 0.00E+00 1.12E-21 7.30E-07 9.04E-04 2.01E-02 4.33E-02 8.26E-02 1.18E-01 ULI WALL 4 0.00E+00 1.13E-21 7.38E-07 9.13E-04 2.03E-02 4.37E-02 8.34E-02 1.20E-01 LLI WALL 5 0.00E+00 1.05E-21 6.88E-07 8.51E-04 1.89E-02 4.08E-02 7.78E-02 1.11E-01 TESTES 6 0.00E+0-0 9.58E-22 6.25E-07 7.74E-04 1.72E-02 3.71E-02 7.07E-02 1.01E-01 BREASTS 7 0.00E+00 1.93E-21 1.26E-06 1.56E-03 3.47E-02 7.48E-02 1.43E-01 2.05E-01 BONE SUR 8 0.00E+00 1.54E-21 1.01E-06 1.25E-03 2.77E-02 5.98E-02 1.14E-01 1.64E-01 RMAIRROW 9 0.00E+00 1.69E-21 1.10E-06 1.37E-03 3.03E-02 6.55E-02 1.25E-01 1.79E-01 THYROID 10 0.00E+0O0 4.43E-18 2.89E-03 3.58E+00 7.96E+01 1.72E+02 3.28E+I02 4.70E+02 KIDNEYS 11 0.00E+00 1.25E-21 8.17E-07 1.01E-03 2.25E-02 4.84E-02 9.24E-02 1.32E-01 LIVER 12 0.00E+00 1.57E-21 1.02E-06 1.27E-03 2.81E-02 6.07E-02 1.16E-01 1.66E-01 SPLEEN 13 0.00E+00 1.62E-21 1.05E-06 1.30E-03 2.89E-02 6.24E-02 1.19E-01 1.71E-01 PANCREAS 14 0.00E+00 1.81E-21 1.18E-06 1.46E-03 3.23E-02 6.98E-02 1.33E-01 1.91E-01 MUSCLE 15 0.00E+'00 1.93E-21 1.26E-06 1.56E-03 3.47E-02 7.48E-02 1.43E-01 2.05E-01 SKIN 16 0.00E+00 1.37E-21 8.93E-07 1.11E-03 2.46E-02 5.30E-02 1.01E-01 1.45E-01 THYMUS 18 0.00E+00 4.15E-21 2.71E-06 3.36E-03 7.46E-02 1.61E-01 3.07E-01 4.40E-01 BL WALL 19 0.00E+00 1.01E-21 6.61E-07 8.18E-04 1.82E-02 3.92E-02 7.48E-02 1.07E-01 ADRENALS 20 0.O0E+00 1.71E-21 1.12E-06 1.38E-03 3.07E-02 6.61E-02 1.26E-01 1.81E-01 ESOPHAGU 21 0.00E+00 4.15E-21 2.71E-06 3.36E-03 7.46E-02 1.61E-01 3.07E-01 4.40E-01 OVARIES 22 0.00E+0I0 9.97E-22 6.50E-07 8.05E-04 1.79E-02 3.85E-02 7.35E-02 1.05E-01 UTERUS 23 0.00E+00 1.06E-21 6.90E-07 8.54E-04 1.90E-02 4.09E-02 7.80E-02 1.12E-01 ORGANS WITH NO CALCULATED DOSE HAVE BEEN SUPPRESSED FROM TABLE
TEM-9002 ENGINEERING DESIGN FILE EDF-3124.-0003 09129109 Rev. 2 Rev. 0 Page 17 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC.-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:09 PAGE 5
DOWNWIND DISTANCES (in)
ORGAN NO. 1.00E+i01 1.00E+02 2.00E+02 3.00E+02 4.30E+02 5.00E+02 6.00E+I02 7.00E+02 LUNGS 1 0.00E+00 3.28E-20 2.14E-05 2.65E-02 5.89E-01 L.27E+00 2.42E+00 3.47E+00 S WALL 2 0.00E+00 5.36E-21 3.50E-06 4.33E-03 9.60E-02 2.07E-01 3.95E-01 5.65E-01 SIWALL 3 0.00E+00 1.12E-21 7.30E-07 9.04E-04 2.01E-02 4.33E-02 8.26E-02 1.18E-01 ULI WALL 4 0.00E+00 1.13E-21 7.38E-07 9.13E-04 2.03E-02 4.37E-02 8.34E-02 1.20E-01 LLI WALL 5 0.00E+00 1.05E-21 6.88E-07 8.51E-04 1.89E-02 4.08E-02 7.78E-02 1.11E-01 TESTES 6 0.00E+00 9.58E-22 6.25E-07 7.74E-04 1.72E-02 3.71E-02 7.07E-02 1.01E-01 BREASTS 7 0.00E+I00 1.93E-21 1.26E-06 1.56E-03 3.47E-02 7.48E-02 1.43E-01 2.05E-01 BONE SUR 8 0.00E+00 1.54E-21 1.01E-06 1.25E-03 2.77E-02 5.98E-02 1.14E-01 1.64E-01 RMARROW 9 0.00E+00 1.69E-21 1.10E-06 1.37E-03 3.03E-02 6.55E-02 1.25E-01 1.79E-01 THYROID 10 0.00E+00 4.43E-18 2.89E-03 3.58E+00 7.96E+01 1.72E+02 3.28E+02 4.70E+02 KTIDNEYS 11 0.00E+00 1.25E-21 8.17E-07 1.01E-03 2.25E-02 4.84E-02 9.24E-02 1.32E-01 LIVER 12 0.00E+00 1.57E-21 1.02E-06 1.27E-03 2.81E-02 6.07E-02 1.16E-01 1.66E-01 SPLEEN 13 0.00E+I00 1.62E-21 1.05E-06 1.30E-03 2.89E-02 6.24E-02 1.19E-01 1.71E-01 PANCREAS 14 0.00E+00 1.81E-21 1.18E-06 1.46E-03 3.23E-02 6.98E-02 1.33E-01 1.91E-01 MvUSCLE 15 0.00E+00 1.93E-21 1.26E-06 1.56E-03 3.47E-02 7.48E-02 1.43E-01 2.05E-01 SKIN 16 0.00E+00 1.37E-21 8.93E-07 1.11E-03 2.46E-02 5.30E-02 1.01E-01 1.45E-01 THIYMvUS 18 0.00E+00 4.15E-21 2.71E-06 3.36E-03 7.46E-02 1.61E-01 3.07E-01 4.40E-01 BLWALL 19 0.00E+I00 1.01E-21 6.61E-07 8.18E-04 1.82E-02 3.92E-02 7.48E-02 1.07E-01 ADRENALS 20 0.00E+00 1.71E-21 1.12E-06 1.38E-03 3.07E-02 6.61E-02 1.26E-01 1.81E-01 ESOPHAGU 21 0.00E+I00 4.15E-21 2.71E-06 3.36E-03 7.46E-02 1.61E-01 3.07E-01 4.40E-01 OVARIES 22 0.00E+00 9.97E-22 6.50E-07 8.05E-04 1.79E-02 3.85E-02 7.35E-02 1.05E-01 UTERUS 23 0.00E+00 1.06E-21 6.90E-07 8.54E-04 1.90E-02 4.09E-02 7.80E-02 1.12E-01 ORGANS WITH NO CALCULATED DOSE HAVE BEEN SUPPRESSED FROM TABLE
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 18 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIMVE 08:09 PAGE 6
- Iodine MIIA Analysis INHALATION WEIGHTED COMMVITTED DOSE EQUIVALENTS (rem)
DOWNWIND DISTANCES (in)
ORGAN NO. 1.00E+01 1.00E+02 2.00E+I02 3.00E+02 4.30E+02 5.00E+02 6.00E+02 7.00E+02 LUNGS 1 0.00E+00 3.94E-21 2.57E-06 3.18E-03 7.07E-02 1.52E-01 2.91E-01 4.17E-01 S WALL 2 0.00E+0-0 3.22E-22 2.10E-07 2.60E-04 5.76E-03 1.24E-02 2.37E-02 3.39E-02 SI WALL 3 0.00E+I00 6.72E-23 4.38E-08 5.43E-05 1.20E-03 2.60E-03 4.96E-03 7.10E-03 ULI WALL 4 0.00E+00 6.79E-23 4.43E-08 5.48E-05 1.22E-03 2.62E-03 5.01E-03 7.17E-03 LLI WALL 5 0.00E+00 6.32E-23 4.13E-08 5.11E-05 1.13E-03 2.45E-03 4.67E-03 6.69E-03 TESTES 6 0.00E+00 2.40E-22 1.56E-07 1.93E-04 4.29E-03 9.26E-03 1.77E-02 2.53E-02 BREASTS 7 0.00E+00 2.90E-22 1.89E-07 2.34E-04 5.20E-03 1.12E-02 2.14E-02 3.07E-02 BONE SUIR 8 0.00E+00 4.63E-23 3.02E-08 3.74E-05 8.32E-04 1.79E-03 3.42E-03 4.91E-03 RMARROW 9 0.00E+00 2.03E-22 1.32E-07 1.64E-04 3.64E-03 7.85E-03 1.50E-02 2.15E-02 THYROID 10 0.00E+00 1.33E-19 8.67E-05 1.07E-01 2.39E+00 5.15E+0-0 9.84E+00 1.41E+01 KIDNEYS 11 0.00E+00 '7.51E-23 4.90E-08 6.07E-.05 1.35E-03 2.91E-03 5.54E-03 7.94E-03 LIVER 12 0.00E+00 9.42E-23 6.14E-08 7.61E-05 1.69E-03 3.64E-03 6.95E-03 9.95E-03 SPLEEN 13 0.00E+00 9.69E-23 6.32E-08 7.83E-05 1.74E-03 3.75E-03 7.15E-03 1.02E-02 PANCREAS 14 0.00E+00 1.08E-22 7.06E-08 8.74E-05 1.94E-03 4.19E-03 7.98E-03 1.14E-02 MUSCLE 15 0.00E+00 1.16E-22 7.56E-08 9.37E-05 2.08E-03 4.49E-03 8.56E-03 1.23E-02 SKIN 16 0.00E+00 1.37E-23 8.93E-09 1.11E-05 2.46E-04 5.30E-04 1.01E-03 1.45E-03 THYMUS 18 0.00E+00 2.49E-22 1.63E-07 2.01E-04 4.48E-03 9.66E-03 l.84E-02 2.64E-02 BL WALL 19 0.00E+00 6.08E-23 3.97E-08 4.91E-05 1.09E-03 2.35E-03 4.49E-03 6.43E-03 ADRENALS 20 0.00E+00 1.03E-22 6.69E-08 8.29E-05 1.84E-03 3.97E-03 7.57E-03 1.08E-02 ESOPHAGU 21 0.00E+00 2.49E-22 1.63E-07 2.01E-04 4.48E-03 9.66E-03 1.84E-02 2.64E-02 OVARIES 22 0.00E+00 2.49E-22 1.62E-07 2.01E-04 4.47E-03 9.64E-03 1.84E-02 2.63E-02 UTERUS 23 0.00E+0-0 6.35E-23 4.14E-08 5.13E-05 1.14E-03 2.45E-03 4.68E-03 6.71E-03 CEDE 24 0.00E+00 1.38E-19 9.03E-05 1.12E-01 2.49E+00 5.37E+00 1.02E+I01 1.47E+01 ORGANS WITH NO CALCULATED DOSE HAVE BEEN SUPPRESSED FROM TABLE
- GAMMA DOSE CALCULATION WITH EXPOSURE TIME = 7.1994E+03 (s)
CALCULATIONS MADE USING THlE FINiTE MODEL EXTERNAL EDE DOWNWIND DISTANCE =l.000E+0l (in)
DOSE = 3.10E-01 (rem)
DOWNWIND DISTANCE = 1.000E+02 (mn)
DOSE = 5.96E-01 (rem)
DOWNWIND DISTANCE =2.000E+02 (mn)
DOSE = 5.75E-01 (rem)
DOWNWIND DISTANCE = 3.000E+02 (in)
DOSE = 5.46E-01 (rem)
DOWNWIND DISTANCE = 4.300E+02 (in)
DOSE = 5.19E-01 (rem)
DOWNWIND DISTANCE = 5.000E+02 (in)
DOSE = 5.09E-01 (remn)
DOWNWIND DISTANCE =6.000E+02 (in)
DOSE = 4.91E-01 (remn)
DOWNWIND DISTANCE = 7.000E+02 (in)
DOE=47E0(rm DOSE = 4.70E-01 (rein)
TEM-9002 09129109 Rev. 0 ENGINEERING DESIGN FILE EDF-3124-0003 Rev. 2 Page 19 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:09 PAGE 7
- Iodine MHA Analysis EXECUTION time =2.80E-01 SECONDS
TEM-9002 ENGINEERING DESIGN FILE EDF-31 24-0003 09/29/09 Rev. 2 Rev. 0 Page 20 of 59 RSAC-6IINPUJT 20160121 08:12 o
1 2
3 4
5 6
7 123456789012345678901234567890123456789012345678901234567890 1234567890123456789
- Iodine MVHA Analysis
- Iodine MBA Inventory 2000,0
- Line replaced by WinRp to use temporary external file src 1.txt
- 2002, C:\\Users\\dthorne\\Documents\\Rsac\\Input Files\\Iodine_20 16.txit 2002,srcl.txt 2999
- F Stability and 2 mis 5000,0 500 1,2.,22.86,400., 1240.,0.,0 5 101,800.,900.,1000.,1 100.,1200.,1300.,1400.,1500.
5201,1.389E-4,0.
5400,2,0.,0.,0 5410,3,6,0 5999
- Dose Data 7000,0, -2,1,0,1 700 1,3.47E-04,0.,0,0, 1.
7999
- Cloud Gaimna 9000,0,0.
10000 0
1 2
3 4
5 6
7 123456789012345678901234567890123456789012345678901234567890 1234567890123456789
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 21 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 T]EvIE8:12 PAGE 1
- Iodine MHA Analysis
- DIIRECT RADIONUCLIDE INPUT ANY PREVIOUS INVENTORY HAS BEEN ZEROED NUCLIDE HALF LIFE CURIES 531290 1129 1.570E+07 yr 3.670E-05 531300 1130 1.236E+l01 h 9.060E-01 531310 1131 8.021E+00 d 1.700E+04 531320 1132 2.295E+l00 h 2.540E+04 531330 1133 2.080E+01 h 3.320E+04 531331 1133m 9.000E+00 s 5.500E+00 531340 1134 5.250E+01 m 3.390E+I02 531350 1135 6.570E+00 h 1.720E+04
- METEOROLOGICAL DATA MEAN WIND SPEED = 2.000E+00 (mis) STACK HEIGHT = 2.286E+01 (in)
MIXING LAYER HEIGHT = 4.000E+02 (in)
AIR DENSITY -- 1.240E+03 (g/cu in)
WET DEPOSITION SCAVENGING COEFFICIENT = 0.000E+00 (l/S)
NO CORRECTION IS BEING MADE FOR PLUME DEPLETION BY FALLOUT DEFAULT DRY DEPOSITION VELOCITIES (mis)
SOLIDS = 0.000E+I00 HALOGENS = 0.000E+00 NOBLE GASES = 0.000E+00 CESIUM = 0.000E+00 RUTHENIUM = 0.000E+00 THERE ISi1 SET OF LEAKAGE CONSTANTS (K1,K2) 1.389E-04 0.000E+00 PASQUJILL CLASS F METEOROLOGY, P-G SIGMA VALUES ENHANCED DEPOSITION PARAMETERS PARTICLE DIAMETER = 0.000E+00 (in) PARTICLE DENSITY = 0.000E+00 (g/cm3)
DOWNWiND DISTANCE STACK SIGY SIGZ CH!IQ HEIGHT (in)
(in)
(in)
(s/cu in) 8.000E+02 2.286E+01 3.022E+01 1.175E+01 6.754E-05 DOWNWIND DISTANCE STACK SIGY SIGZ CHIIQ HEIGHT (mn) (mn)
(in)
(s/cu mn) 9.000E+02 2.286E+01 3.361E+01 1.285E+01 7.574E-05
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 22 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:12 PAGE 2
- Iodine MHA Analysis DOWNWIND DISTANCE STACK SIGY SIGZ CHJ!Q HIEIGHT (in)
(mn)
(in)
(s/cu in) 1.000E+I03 2.286E+01 3.697E+01 1.399E+01 8.094E-05 DOWNWIND DISTANCE STACK SIGY SIGZ CHI/Q HEIGHT (mn) (in)
(in)
(s/cu m) 1.100E+03 2.286E+01 4.029E+01 1.507E+01 8.294E-05 DOWNWIND DISTANCE STACK SIGY SIGZ CHIIQ HEIGHT (in)
(in)
(in)
(s/cu mn) 1.200E+I03 2.286E+01 4.359E+I01 1.607E+01 8.263E-05 DOWNWIND DISTANCE STACK SIGY SIGZ CHIIQ HEIGHT (in)
(in)
(mn)
(s/cu m) 1.300E+03 2.286E+01 4.685E+01 1.701E+01 8.095E-05 DOWNWIND DISTANCE STACK SIGY SIGZ CHIIQ HEIGHT (in)
(in)
(in)
(s/cu mn) 1.400E+0)3 2.286E+01 5.010E+01 1.789E+O1 7.851E-05 DOWNWIND DISTANCE STACK SIGY SIGZ CHIIQ HEIGHT (in)
(in)
(in)
(s/cu m) 1.500E+03 2.286E+01 5.332E+l01 1.872E+01 7.566E-05
- INHALATION DOSE EQUIVALENT CALCULATION USING DOSE CONVERSION FACTORS FROM FEDERAL GUIDANCE REPORT 11 RESPIRABLE FRACTION =.000E+00 BREATHING RATE = 3.470E-04 (cu m/s)
RELEASE TIME FOR EXPONENTIAL DECAY FUNCTION -- 7.199E+03 (s)
INTERNAL EXPOSURE TIME PERIOD =5.000E+0 1 (yr)
PARTICLE SIZE = 1.0 MICRON AMAD LUNG DEPOSITION FRACTIONS: N-P = 0.300 T-B = 0.080 P = 0.250 DEFAULT ELEMENT LUNG CLEARANCE CLASSES SELECTED TO GIVE MAXIMUM DOSE
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 23 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:12 PAGE 3
- Iodine MHA Analysis DOWNWIND DISTANCE = 8.O00E+02 (in)
PLUME TRAVEL TIME =4.O00E+02 (s)
CHI/Q =6.754E-05 (s/cu mn)
DOWNWIND DISTANCE = 9.000E+02 (In)
PLUME TRAVEL TIME = 4.500E+02 (s)
CHIIQ = 7.574E-05 (s/cu im)
DOWNWIND DISTANCE = 1.000E+03 (in)
PLUME TRAVEL TIME = 5.000E+i02 (s)
CHIIQ =8.094E-05 (s/cu in)
DOWNWIND DISTANCE = 1.100E+03 (in)
PLUME TRAVEL TIME = 5.500E+02 (s)
CHIIQ = 8.294E-05 (s/cu m)
DOWNWIND DISTANCE = 1.200E+03 (in)
PLUME TRAVEL TIME =6.000E+-02 (s)
CHIIQ =8.263E-05 (s/cu in)
DOWNWIND DISTANCE = 1.300OE+03 (in)
PLUME TRAVEL TIME = 6.500E+02 (s)
CHIIQ = 8.095E-05 (s/cu in)
DOWNWIND DISTANCE =1.400E+03 (in)
PLUME TRAVEL TIME = 7.000E+i02 (s)
CHIIQ = 7.85 1E-05 (s/cu in)
DOWNWIND DISTANCE = 1.500E+03 (in)
PLUME TRAVEL TIME = 7.500E+02 (s)
CHI/Q = 7.566E-05 (s/cu in)
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 24 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:12 PAGE 4
DOWNWIND DISTANCES (in)
ORGAN NO. 8.00E+02 9.00E+02 1.00E+03 1.10E+03 1.20E+l03 1.30E+03 1.40E+i03 1.50E+03 LUNGS 1 4.26E+0-0 4.77E+00 5.10E+00 5.22E+00 5.20E+00 5.09E+00 4.93E+00 4.74E+00 S WALL 2 6.93E-01 7.76E-01 8.28E-01 8.48E-01 8.43E-01 8.25E-01 7.99E-01 7.69E-01 SI WALL 3 1.45E-01 1.63E-01 1.74E-01 1.78E-01 1.77E-O1 1.73E-01 1.68E-01 1.61E-01 ULI WALL 4 1.47E-01 1.64E-01 1.75E-01 1.80E-01 1.79E-01 1.75E-01 1.69E-01 1.63E-01 LLIWALL 5 1.37E-01 1.53E-01 1.63E-01 1.67E-01 1.67E-01 1.63E-01 1.58E-O1 1.52E-01 TESTES 6 1.24E-01 1.39E-01 1.49E-01 1.52E-01 1.51E-01 1.48E-01 1.44E-01 1.38E-01 BREASTS 7 2.51E-01 2.81E-O1 3.00E-01 3.08E-01 3.06E-01 3.00E-01 2.90E-01 2.80E-01 BONE SUR 8 2.01E-01 2.25E-01 2.40E-01 2.46E-01 2.45E-01 2.40E-01 2.32E-01 2.24E-01 R MARROW 9 2.20E-01 2.46E-01 2.63E-01 2.69E-01 2.68E-01 2.62E-01 2.54E-01 2.45E-01 THYROID 10 5.78E+02 6.48E+02 6.92E+02 7.09E+02 7.06E+I02 6.92E+l02 6.71E+I02 6.46E+02 KTIDNEYS 11 1.62E-01 1.82E-01 1.94E-01 1.99E-01 1.98E-01 1.94E-01 1.88E-01 1.81E-01 LIVER 12 2.03E-01 2.28E-01 2.43E-01 2.49E-O1 2.48E-01 2.43E-01 2.35E-01 2.26E-01 SPLEEN 13 2.09E-01 2.34E-01 2.50E-01 2.56E-01 2.55E-01 2.49E-01 2.42E-01 2.33E-01 PANCREAS 14 2.34E-01 2.62E-01 2.80E-01 2.86E-01 2.85E-01 2.79E-01 2.70E-01 2.60E-01 MUSCLE 15 2.51E-01 2.81E-01 3.00E-01 3.08E-01 3.06E-01 3.00E-01 2.90E-01 2.80E-01 SKIN 16 1.78E-01 1.99E-01 2.13E-01 2.18E-01 2.17E-01 2.12E-01 2.06E-01 1.98E-01 THYMUS 18 5.40E-01 6.06E-01 6.47E-01 6.62E-01 6.59E-01 6.46E-01 6.26E-01 6.03E-01 BLWALL 19 1.31E-O1 1.47E-01 1.57E-01 1.61E.-01 1.60E-01 1.57E-01 1.52E-01 1.46E-01 ADRENALS 20 2.22E-01 2.48E-01 2.65E-01 2.71E-01 2.70E-01 2.64E-01 2.56E-01 2.47E-01 ESOPHAGU 21 5.40E-01 6.06E-01 6.47E-01 6.62E-01 6.59E-01 6.46E-01 6.26E-01 6.03E-01 OVARIES 22 1.29E-01 1.45E-01 1.55E-01 1.58E-01 1.58E-01 1.54E-01 1.49E-O1 1.44E-01 UTERUS 23 1.37E-01 1.54E-01 1.64E-01 1.68E-01 1.67E-01 1.64E-01 1.58E-01 1.53E-01 ORGANS WITH NO CALCULATED DOSE HAVE BEEN SUPPRESSED FROM TABLE
TEM-9002.ENGINEERING-DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 25 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6).
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:12 PAGE 5
DOWNWIND DISTANCES (in)
ORGAN NO. 8.00E+02 9.00E+02 1.00E+03 1.10E+03 1.20E+03 1.30E+03 1.40E+03 1.50E+03 THYROID 10 5.78E+02 6.48E+02 6.92E+02 7.09E+02 7.06E+02 6.92E+02 6.71E+02 6.46E+02 LUNGS 1 4.26E+f00 4.77E+00 5.10E+00 5.22E+00 5.20E+00 5.09E+00 4.93E+00 4.74E+00 S WALL 2 6.93E-01 -7.76E-01 8.28E-01 8.48E-01 8.43E-0I 8.25E-01 7.99E-01 7.69E-01 THYMUS 18 5.40E-01 6.06E-01 6.47E-01 6.62E-01 6.59E-01 6.46E-01 6.26E-01 6.03E-01 ESOPHAGU 21 5.40E-01 6.06E-01 6.47E-.01 6.62E-01 6.59E-01 6.46E-01 6.26E-01 6.03E-01 BREASTS 7 2.51E-0i 2.81E-.01 3.00E-01 3.08E-01 3.06E-01 3.00E-01 2.90E-01 2.80E-01 MUSCLE 15 2.51E-01 2.81E-O1 3.00E-01 3.08E-01 3.06E-01 3.00E.-01 2.90E-01 2.80E-01 PANCREAS 14 2.34E-01 2.62E-.01 2.80E-01 2.86E-01 2.85E-01 2.79E-01 2.70E-01 2.60E-01 ADRENALS 20 2.22E-01 2.48E-01 2.65E-O1 2.71E.-01 2.70E-01 2.64E-01 2.56E-01 2.47E-01 R MARROW 9 2.20E-01 2.46E-01 2.63E-01 2.69E-01 2.68E-01 2.62E-01 2.54E-01 2.45E-01 SPLEEN 13 2.09E-01 2.34E-01 2.50E-01 2.56E-01 2.55E-01 2.49E-01 2.42E-01 2.33E-01 LIVER 12 2.03E-01 2.28E-01 2.43E-01 2.49E-01 2.48E-01 2.43E-01 2.35E-01 2.26E-01 BONE STIR 8 2.01E-01 2.25E-01 2.40E-01 2.46E-01 2.45E-01 2.40E-01 2.32E-01 2.24E-01' SKIN 16 1.78E-01 1.99E-01 2.13E-01 2.18E-01 2.17E-01.2.12E-01 2.06E-01 1.98E-01 KIDNEYS 11 1.62E-01 1.82E-01 1.94E-01 1.99E-01 1.98E-01 1.94E-01 1.88E-01 1.81E-01 UILIWALL 4 1.47E-01 1.64E-01 1.75E-01 1.80E-01 1.79E-01 1.75E-01 1.69E-01 1.63E-01 SI WALL 3 1.45E-01 1.63E-01 1.74E-01 1.78E-01 1.77E-01 1.73E-01 1.68E-01 i.61E-01 UTERUS 23 1.37E-01 1.54E-01 1.64E-01 1.68E-01 1.67E-01 1.64E-01 1.58E-01 1,53E-01 LLI WALL 5 1.37E-01 1.53E-01 1.63E-01 1.67E-01 1.67E-01 1.63E-01 1.58E-01 1.52E-01 BLWALL 19 1.31E-01 1.47E-01 1.57E-01 1.61E-01 1.60E-01 1.57E-01 1.52E-01 1.46E-01 OVARIES 22 1.29E-01 1.45E-01 1.55E-01 1.58E-01 1.58E-01 l.54E-01 1.49E-01 1.44E-01 TESTES 6 1.24E-01 1.39E-01 1.49E-01 1.52E-01 1.51E-01 1.48E-01 1.44E-01 l.38E-01 ORGANS WITH NO CALCULATED DOSE HAVE BEEN SUPPRESSED FROM TABLE
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 26 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:12 PAGE 6
DOWNWIND DISTANCES (in)
ORGAN NO. 8.00E+02 9.00E+02 1.00E+I03 1.10E+03 1.20E+03 1.30E+03 1.40E+03 1.50E+03 LUNGS 1 5.11E-01 5.73E-01 6.12E-01 6.26E-01 6.23E-01 6.10E-01 5.91E-01 5.69Eo01 S WALL 2 4.16E-02 4.66E-02 4.97E-02 5.09E-02 5.06E-02 4.95E-02 4.79E-02 4.61E-02 SI WALL 3 8.71E-03 9.76E-03 1.04E-02 1.07E-02 1.06E-02 1.04E-02 1.01E-02 9.69E-03 ULI WALL 4 8.80E-03 9.86E-03 1.05E-02 1.08E-02 1.07E-02 1.05E-02 1.02E-02 9.79E-03 LLIWALL 5 8.20E-03 9.19E-03 9.81E.-03 1.00E-02 9.99E-03 9.78E-03 9.48E-03 9.12E-03 TESTES 6 3.11E-02 3.48E-02 3.72E-02 3.80E-02 3.79E-02 3.71E-02 3.59E-02 3.46E-02 BREASTS 7 3.76E-02 4.22E-02 4.51E-02 4.61E-02 4.59E-02 4.50E-02 4.36E-02 4.20E-02 BONE SUR. 8 6.02E-03 6.75E-03 7.20E-03 7.38E-03 7.34E-03 7.19E-03 6.96E-03 6.71E-03 RMAIRROW 9 2.64E-02 2.95E-02 3.15E-02 3.23E-02 3.21E-02 3.15E-02 3.05E-02 2.94E-02 TH-YROID 10 1.73E+01 1.94E+0-1 2.08E+01 2.13E+0-1 2.12E+01 2.08E+01 2.01E+01 1.94E+01 KIDNEYS 11 9.74E-03 1.09E-02 1.16E-02 1.19E-02 1.19E-02 1.16E-02 1.13E-02 1.08E-02 LIVER 12 1.22E-02 1.37E-02 1.46E-02 1.49E-02 1.49E-02 1.46E-02 1.41E-02 1.36E-02 SPLEEN 13 1.26E-02 1.41E-02 l.50E-02 1.54E.4)2 1.53E-02 1.50E-02 1.45E-02 1.40E-02 PANCREAS 14 1.40E-02 1.57E-02 1.68E-02 1.72E-02 1.71E-02 1.67E-02 1.62E-02 1.56E-02 MUSCLE 15 1.5 1E-02 1.69E-02 1,80E-02 1.85E-02 1.84E-02 1,80E-02 1,74E-02 1.68E-02 SKIN 16 1.78E-03 1.99E-03 2.13E-03 2.18E-03 2.17E-03 2.12E-03 2.06E-03 1.98E-03 TrHYMUS 18 3.24E-02 3.63E-02 3.88E-02 3.97E-02 3.96E-02 3.87E-02 3.75E-02 3.62E-02 BL WALL 19 7.89E-03 8.83E-03 9.43E-03 9.65E-03 9.6 1E-03 9.40E-03 9.11E-03 8.77E-03 ADRENALS 20 1.33E-02 1.49E-02 1.59E-02 1.63E-02 1.62E-02 1.59E-02 1.54E-02 1.48E-02 ESOPHAGU 21 3.24E-02 3.63E-02 3.88E-02 3.97E-02 3.96E-02 3.87E-02 3.75E-02 3.62E-02 OVARIES 22 3.23E-02 3.62E-02 3.87E-02 3.96E-02 3.94E-02 3.85E-02 3.73E-02 3.60E-02 UTERUS 23 8.23E-03 9.22E-03 9.84E3-03 1.01E-02 1.00E-02 9.81E-03 9.51E-03 9.15E-03 CEDE 24 1.80E+01 2.02E+0-1 2.16E+01 2.21E+01 2.21E+01 2.16E+0-1 2.09E+01 2.02E+-01 ORGANS WITH NO CALCULATED DOSE HAVE BEEN SUPPRESSED FROM TABLE
- GAMMA4~ DOSE CALCULATION WITH EXPOSURE TIMVE = 7. 1994E+03 (s)
CALCULATIONS MADE USING THE FINITE MODEL EXTERNAL EDE DOWNWIND DISTANCE = 8.000E+02 (in)
DOSE = 4.48E-01 (rem)
DOWNWIND DISTANCE = 9.000E+02 (in)
DOSE = 4.26E-01 (remn)
DOWNWIND DISTANCE = 1.000E+03 (in)
DOWNWIND DISTANCE = 1.100E+03 (in)
DOSE = 3.92E-01 (rem)
DOWNWIND DISTANCE = !.200E+03 (in)
DOSE = 3.76E-01 (rem)
DOWNWIND DISTANCE = 1.300E+-03 (mn)
DOSE = 3.60E-01 (rein)
DOWNWIND DISTANCE = 1.400E+03 (in)
DOSE = 3.45E-O1 (rem)
DOWNWIND DISTANCE = 1.500E+03 (mn)
DS=33EO r
DOSE = 3.31E-01 (rem)
TEM-9002 09129109 Rev. 0 ENGINEERING DESIGN FILE EDF-31 24-0003 Rev. 2 Page 27 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:12 PAGE 7
- Iodine MHA Analysis EXECUTION time = 2.90E-01 SECONDS
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09/29/09 Rev. 2 Rev. 0 Page 28 of 59 RSAC-6 INPUT 20160121 07:51 0
1 2
3 4
5 6
7.
123456789012345678901234567890123456789012345678901234567890 12345678901t23456789
- Krypton MBA Analysis
- Line replaced by WinRp to use temporary external file srcl.txt
- 2002,C:\\Users\\dthorne\\Documents\\Rsac\\Input Files\\Krypton_2016.txt 2002, srcl.txt 2999
- F Stability and 2 m/s 5000,0 500 1,2.,22.86,400., 1240.,0.,0 5101, 10., 100.,200.,300.,430.,500.,600.,700.
5201,1.389E-4,0.
5400,2,0.,0.,0 5410,3,6,0 5999
- Dose Data.
7000,0,-2, 1,0,1 700 1,3.47E-04,0.,0,0, 1.
7999
- Gloud Gamma 9000,0,0.
10000 0
1 2
3 4
5 6
7 123456789012345678901234567890123456789012345678901234567890 1234567890123456789
TEM-9002 ENGINEERING DESIGN FILE EDF-31 24-0003 09129109 Rev. 2 Rev. 0 Page 29 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC..6)
(RSAC..6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 07:5 1PAGE 1
- Krypton MHA Analysis
- DIPECT RADIONUCLIDE INPUT ANY PREVIOUS INVENTORY HAS BEEN ZEROED NUCLIDE HALF LIFE CURIES 360831 Kr83m 1.830E+00 h 9.650E+02 360850 Kr85 1.076E+01 yr 2.980E+01 360851 Kr 85m 4.480E+01 h 2.360E+03 360870 Kr 87 7.630E+01 m 2.120E+02 360880 Kr 88 2.840E+00 h 3.180E+03
- METEOROLOGICAL DATA MEAN WIND SPEED = 2.000E+00 (m/s) STACK HEIGHT =2.286E+01 (in)
MIXING LAYER HEIGHT = 4.000E+02 (in)
AIR DENSITY = 1.240E+03 (g/cu m)
WET DEPOSITION SCAVENGING COEFFICIENT --0.000E+00 (1/S)
NO CORRECTION IS BEING MADE FOR PLUME DEPLETION BY FALLOUT DEFAULT DRY DEPOSITION VELOCITIES (m/s)
SOLIDS = 0.000E+00 HALOGENS = 0.000E+00 NOBLE GASES = 0.000E+00 CESIUM = 0.000E+00 RUTHENIUM = 0.000E+00 THERE IS 1 SET OF LEAKAGE CONSTANTS (K1,K2) 1.389E-04 0.000E+00 PASQUILL CLASS F METEOROLOGY, P-G SIGMA VALUES WARNING - DIFFUSION FOR DISTANCES OF LESS THAN 100 METERS IS EXTRAPOLATED ENHANCED DEPOSITION PARAMETERS PARTICLE DIAMETER = 0.000E+00 (mn) PARTICLE DENSITY = 0.000E+00 (g/cm3)
DOWNWIND DISTANCE STACK SIGY SIGZ CHI!Q HEIGHT (in) (mn)
(in)
(s/cu mn) 1.000E+01 2.286E+01 5.776E-01 3.454E-01 0.000E+00 DOWNWIND DISTANCE STACK SIGY SIGZ CHIIQ HEIGHT (mn) (mn)
(mn)
(s/cu m) 1.000E+f02 2.286E+01 4.621E+00 2.247E+I00 5.171E-25
TEM-9002 09129109 Rev. 0 ENGINEERING DESIGN FILE EDF-31 24-0003 Rev. 2 Page 30 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 07:5 1PAGE 2
- Krypton MHA Analysis DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 2.000E+02 2.286E+0O1 8.642E+00 DOWNWIND DISTANCE STACK HEIGHT (in)
(mn)
(in) 3.000E+02 2.286E+01 1.246E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 4.300E-+02 2.286E+01 1.725E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 5.000E+I02 2.286E+01 1.977E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 6.000E+02 2.286E+0-1 2.331E+01.
DOWNWIND DISTANCE STACK HEIGHT (in)
(mn)
(in) 7.000E+02 2.286E+01 2.679E+01 SIGY SIGZ CHI/Q (s/cu mn) 3.988E+-00 3.376E-10 SIGY SIGZ CIJI/Q (s/cu in) 5.506E+00 4. 185E-07 SIGY SIGZ CHI/IQ (s/cu in) 7.293E+00 9.302E-06 SIGY SIGZ CHI/Q (s/cu in) 8.I95E+00 2.008E-05 SIGY SIGZ CHI/Q (s/cu in) 9.430E+00 3.834E-05 SIGY SIGZ CHIIQ (s/cu mn) 1.061E+01 5.500E-05
- INHALATION DOSE EQUIVALENT CALCULATION USING DOSE CONVERSION FACTORS FROM FEDERAL GUIDANCE REPORT 11 RESPIRABLE FRACTION = 1.000E+00 BREATHING RATE = 3.470E-04 (cu nm/s)
RELEASE TIME FOR EXPONENTIAL DECAY FUNCTION = 7.I199E+03 (s)
INTERNAL EXPOSURE TIME PERIOD =5.000E+0I (yr)
PARTICLE SIZE = 1.0 MICRON AMAD LUNG DEPOSITION FRACTIONS: N-P = 0.300 T-B =0.080 P = 0.250 DEFAULT ELEMENT LUNG CLEARANCE CLASSES SELECTED TO GIVE MAXIMUM DOSE
TEM-9002
.ENGINEERING DESIGN FILE EDF-31 24-0003 09/29/09 Rev. 2 Rev. 0 Page 31 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 07:5 1PAGE 3
- Krypton MHA Analysis DOWNWIND DISTANCE = 1.000E+01 (in)
PLUME TRAVEL TIME =5.000E+00 (s)
CEHI/Q = 0.000E+00 (s/cu m)
DOWNWIND DISTANCE = 1.000E+02 (mn) PLUME TRAVEL TIME = 5.000E+01 (s)
CHI/Q = 5. 171E-25 (s/cu m)
DOWNWIND DISTANCE -- 2.000E+02 (mn) PLUME TRAVEL TIME = 1.000E+I02 (s)
CHI/IQ = 3.376E3-10 (s/cu mn)
DOWNWIND DISTANCE = 3.000E+02 (in)
PLUME TRAVEL TIMVE = 1.500E+02 (s)
CHTIQ = 4. 185E-07 (s/cu in)
DOWNWIND DISTANCE = 4.300OE+02 (in)
PLUME TRAVEL TIME = 2. 150E+02 (s)
CHI/Q = 9.302E-06 (s/cu in)
DOWNWIND DISTANCE = 5.000E+02 (in)
PLUME TRAVEL TIME =2,500E+-02 (s)
CHI/IQ = 2.008E-05 (s/cu in)
DOWNWIND DISTANCE = 6.000E+02 (in)
PLUME TRAVEL TIME = 3.000E+I02 (s)
CHIIQ = 3.834E-05 (s/cu in)
DOWNWIND DISTANCE = 7.000E+02 (in)
PLUME TRAVEL TIME = 3.500E+02 (s)
CIII/Q = 5.500E-05 (s/cu in)
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 32 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 07:51 PAGE 4
DOWNWIND DISTANCES (in)
ORGAN NO. 1.00E+01 1.00E+02 2.00E+02 3.00E+02 4.30E+102 5.00E+02 6.00E+0i2 7.00E+02 LUNGS 1 0.00E+00 2.03E-22 1.34E-07 1.67E-04 3.74E-03 8.10E-03 1.55E-02 2.24E-02 S WALL 2 0.00E+00 8.56E-23 5.62E-08 7.02E-05 1.57E-03 3.41E-03 6.54E-03 9.42E-03 SI WALL 3 0.00E+0-0 2.23E-24 1.46E-09 1.83E-06 4.L0E-05 8.88E-05 1.71E-04 2.46E-04 ULI WALL 4 0.00E+0-0 2.70E-24 1.78E-09 2.22E-06 4.98E-05 1.08E-04 2.08E-04 3.00E-04 LLI WALL 5 0.00E+00 3.40E-24 2.24E-09 2.80E-06 6.28E-05 1.36E-04 2.62E-04 3.79E-04 TESTES 6 0.00E+00 1.73E-24 1.14E-09 1.42E-06 3.18E-05 6.89E-05 1.32E-04 1.91E-04 BREASTS 7 0.00E+00 2.04E-24 1.34E-09 1.67E-06 3.74E-05 8.10E-05 1.56E-04 2.24E-04 BONE STUR 8 0.00E+00 2.07E-24 1.36E-09 1.70E-06 3.81E-05 8.25E-05 1.58E-04 2.28E-04 RMARROW 9 0.00E+i00 2.09E-24 l.37E-09 1.71E-06 3.83E-05 8.31E-05 1.59E-04 2.30E-04 THYROID 10 0.00E+I00 1.92E-24 1.26E-09 1.57E-06 3.52E-05 7.63E-05 1.47E-04 2.11E-04 KIDNEYS 11 0.00E+0-0 2.04E-24 1.34E-09 1.68E-06 3.75E-05 8.14E-05 1.56E-04 2.25E-04 LIVER 12 0.00E+O0 2.28E-24 1.50E-09 1.87E-06 4.19E-05 9.09E-05 1.75E-04 2.52E-04 SPLEEN 13 0.00E+00 2.48E-24 1.63E-09 2.03E-06 4.56E-05 9.87E-05 1.90E-04 2.73E-04 PANCREAS 14 0.00E+00 2.85E-24 1.87E-09 2.34E-06 5.23E-05 1.13E-04 2.18E-04 3.14E-04 MUSCLE 15 0.00E+00 2.04E-24 1.34E-09 1.67E-06 3.74E-05 8.10E-05 1.56E-04 2.24E-04 SKIN 16 0.00E+00 1.82E-24 1.19E-09 1.49E-06 3.34E-05 7.23E-05 1.39E-04 2.00E-04 BRAIN 17 0.00E+00 1.70E-24 1.12E-09 1.39E-06 3.12E-05 6.76E-05 1.30E-04 1.87E-04 THYMUS 18 0.00E+00 2.57E-24 1.69E-09 2.11E-06 4.72E-05 1.02E-04 1.96E-04 2.83E-04 EL WAIL 19 0.00E+0-0 1.82E-24 1.20E-09 1.50E-06 3.3 5E-05 7.27E-05 1.40E-04 2.01E-04 ADRENALS 20 0.00E+00 2.23E-24 1.47E-09 1.83E-06 4.10E-05 8.88E-05 1.71E-04 2.46E-04 ESOPHAGU 21 0.00E+i00 2.57E-24 1.69E-09 2.11E-06 4.72E-05 1.02E-04 1.96E-04 2.83E-04 OVARIES 22 0.00E+0I0 2.07E-24 1.36E-09 1.70E-06 3.80E-05 8.25E-05 1.58E-04 2.29E-04 UTERUS 23 0.00E+i00 1.92E-24 1.26E-09 1.58E-06 3.53E-05 7.66E-05 1.47E-04 2.12E-04
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 33 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 07:51 PAGE 5
- Krypton MHA Analysis INHALATION COMMIT1TED DOSE EQUIVALENCES ORDERED BYDOSE (remn)
DOWNWIND DISTANCES (in)
ORGAN NO. 1.00E+01 1.00E+02 2.00E+02 3.00E+02 4.30E+02 5.00E+02 6.00E+02 7.00E+02 LUNGS 1 0.00E+00 2.03E-22 1.34E-07 1.67E-04 3.74E-03 8.10E-03 1.55E-02 2.24E-02 S WALL 2 0.00E+00 8.56E-23 5.62E-08 7.02E-05 1.57E-03 3.41E-03 6.54E-03 9.42E-03 SI WALL 3 0.00E+i00 2.23E-24 1.46E-09 1.83E-06 4.10E-05 8.88E-05 1.71E-04 2.46E-04 ULI WALL 4 0.00E+00 2.70E-24 1.78E-09 2.22E-06 4.98E-05 1.08E-04 2.08E-04 3.00E-04 LUI WALL 5 0.00E+00 3.40E-24 2.24E-09 2.80E-06 6.28E-05 1.36E-04 2.62E-04 3.79E-04 TESTES 6 0.00E+00 1.73E-24 1.14E-09 1.42E-06 3.18E-05 6.89E-05 1.32E-04 1.91E-04 BREASTS 7 0.00E+I00 2.04E-24 1.34E-09 1.67E-06 3.74E-05 8.10E-05 1.56E-04 2.24E-04 BONE SUR 8 0.00E+00 2.07E-24 1.36E-09 1.70E-06 3.81E-05 8.25E-05 1.58E-04 2.28E-04 RMARROW 9 0.00E+00 2.09E-24 1.37E-09 1.71E-06 3.83E-05 8.31lE-05 1.59E-04 2.30E-04 THYROID 10 0.00E+00 1.92E-24 1.26E-09 1.57E-06 3.52E-05 7.63E-05 1.47E-04 2.11E-04 KIDNEYS 11 0.00E+00 2.04E-24 1.34E--09 1.68E-06 3.75E-05 8.14E-05 1.56E-04 2.25E-04 LIVER 12 0.00E+00 2.28E-24 1.50E-09 1.87E-06 4.19E-05 9.09E-05 1.75E-04 2.52E-04 SPLEEN 13 0.00E+00O 2.48E-24 1.63E-09 2.03E-06 4.56E-05 9.87E-05 1.90E-04 2.73E-04 PANCREAS 14 0.00E+I00 2.85E-24 1.87E-09 2.34E-06 5.23E-05 1.13E-04 2.18E-04 3.14E-04 MUSCLE 15 0.00E+00 2.04E-24 1.34E-09 1.67E-06 3.74E-05 8.10E-05 1.56E-04 2.24E-04 SKIN 16 0.00E+00 1.82E-24 1.19E-09 1.49E-06 3.34E-05 7.23E-05 1.39E-04 2.00E-04 BRAIN 17 0.00E+00 1.70E-24 1.12E-09 1.39E-06 3.12E-05 6.76E-05 1.30E-04 1.87E-04 THTYMvUS 18 0.00E+I00 2.57E-24 1.69E-09 2.11E-06 4.72E-05 1.02E-04 1.96E-04 2.83E-04 BL WALL 19 0.00E+00 1.82E-24 1.20E-09 1.50E-06 3.35E-05 7.27E-05 1.40E-04 2.01E-04 ADRENALS 20 0.00E+00 2.23E-24 1.47E-09 1.83E-06 4.10E-05 8.88E-05 1.71E-04 2.46E-04 ESOPHAGU 21 0.00E+00 2.57E-24 1.69E-09 2.11E-06 4.72E-05 1.02E-04 1.96E-04 2.83E-04 OVARIES 22 0.00E+0-0 2.07E-24 1.36E-09 1.70E-06 3.80E-05 8.25E-05 1.58E-04 2.29E-04 UTERUS 23 0.00E+00 1.92E-24 1.26E-09 1.58E-06 3.53E-05 7.66E-05 1.47E-04 2.12E-04
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 34 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-.6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 07:5 1PAGE 6
DOWNWIND DISTANCES (in)
ORGAN NO. 1.00E+01 1.00E+02 2.00E+02 3.00E+02 4.30E+02 5.00E+02 6.00E+02 7.00E+02 LUNGS 1 0.00E+00 2.44E-23 1.60E-08 2.00E-05 4.48E-04 9.72E-04 1.86E-03 2.69E-03 S WALL 2 0.00E+00 5.13E-24 3.37E-09 4.21E-06 9.43E-05 2.04E-04 3.92E-04 5.65E-04 SI WALL 3 0.00E+00 1.34E-25 8.78E-11 1.10E-07 2.46E-06 5.33E-06 1.02E-05 1.48E-05 ULI WALL 4 0.00E+00 1.62E-25 1.07E-10 1.33E-07 2.99E-06 6.48E-06 1.25E-05 1.80E-05 LUIWALL 5 0.00E+00.2.04E-25 1.34E-10 1.68E-07 3.77E-06 8.18E-06 1.57E-05 2.28E-05 TESTES 6 0.00E+00 4.33E-25 2.84E-10 3.55E-07 7.95E-06 1.72E-05 3.31E-05 4.76E-05 BREASTS 7 0.00E+00 3.05E-25 2.01E-10 2.50E-07 5.61E-06 1.22E-05 2.33E-05 3.36E-05 BONE SUR 8 0.00E+O0 6.22E-26 4.09E-11 5.I0E-08 1.14E-06 2.47E-06 4.75E-06 6.85E-06 R MARROW 9 0.00E+00 2.50E-25 1.65E-10 2.05E-07 4.60E-06 9.97E-06 1.91E-05 2.76E-05 TIHYROID 10 0.00E+00 5.75E-26 3.78E-11 4.72E-08 1.06E-06 2.29E-06 4.40E-06 6.34E-06 KIDNEYS 11 0.00E+0-0 1.23E-25 8.06E-11 1.01E-07 2.25E-06 4.88E-06 9.37E-06 1.35E-05 LIVER 12 0.00E+f00 1.3'7E-25 9.00E-11 1.12E-07 2.52E-06 5.45E-06 1.05E-05 1.51E-05 SPLEEN 13 0.00E+00 1.49E-25 9.78E-l1 1.22E-07 2.73E-06 5.92E-06 1.14E-05 1.64E-05 PANCREAS 14 0.00E+00 1.71E-25 1.12E-10 1.40E-07 3.14E-06 6.80E-06 1.31E-05 1.88E-05 MUSCLE 15 0.00E+00 1.22E-25 8.03E-11 1.00E-07 2.24E-06 4.86E-06 9.34E-06 1.35E-05 SKIN 16 0.00E+00 1.82E-26 1.19E-11 1.49E-08 3.34E-07 7.23E-07 1.39E-06 2.00E-06 BRAIN 17 0.00E+00 1.02E-25 6.70E-11 8.35E-08 1.87E-.06 4.05E-06 7.78E-06 1.12E-05 THYMvUS 18 0.00E+00 1.54E-25 1.01E-10 1.26E-07 2.83E-06 6.14E-06 1.18E-05 l.70E-05 BLWALL 19 0.00E+00 1.09E-25 7.20E-11 8.98E-08 2.01E-06 4.36E-06 8.37E-06 1.21E-05 ADRENALS 20 0.00E+00 1.34E-25 8.80E-11 1.10E-07 2.46E-06 5.33E-06 1.02E-05 1.48E-05 ESOPHAGU 21 0.00E+00 1.54E-25 1.01E-10 1.26E-07 2.83E-06 6.14E-06 1.18E-05 1.70E-05 OVARIES 22 0.00E+i00 5.17E-25 3.40E-10 4.24E-07 9.51E-06 2.06E-05 3.96E-05 5.71E-05 UTERUS 23 0.00E+00 1.15E-25 7.58E-11 9.46E-08 2.12E-06 4.60E-06 8.82E-06 1.27E-05 CEDE 24 0.00E+00 3.15E-23 2.07E-08 2.58E-05 5.79E-04 1.25E-03 2.41E-03 3.47E-03
- GAMA4 DOSE CALCULATION WITH EXPOSURE TIME =7.1994E+03 (s)
CALCULATIONS MADE USING THE FINITE MODEL EXTERNAL EDE DOWNWIND DISTANCE = 1.000E+01 (in)
DOSE = 1.88E-02 (remn)
DOWNWIND DISTANCE = 1.000E+02 (in)
DOSE = 3.60E-02 (rem)
DOWNWIND DISTANCE = 2.000E+02 (mn)
DOSE = 3.48E-02 (rem)
DOWNWIND DISTANCE = 3.000E+f02 (mn)
DOSE = 3.31lE-02 (rem)
DOWNWIND DISTANCE = 4.300E+02 (in)
DOSE = 3.15E-02 (rem)
DOWNWIND DISTANCE = 5.000E+02 (in)
DOSE = 3.09E-02 (rem)
DOWNWIND DISTANCE =6.000E+02 (in)
DOE=29E0(rm DOSE = 2.99E-02 (rem)
TEM-9002 09129/09 Rev. 0 ENGINEERING DESIGN FILE EDF-3124-0003 Rev. 2 Page 35 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 07:5 1PAGE 7
- Krypton MHA Analysis DOWNWIND DISTANCE =7.000E+02 (in)
EXECUTION time = 3.20E-01 SECONDS DOSE = 2.86E-02 (rem)
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129/09 Rev. 2 Rev. 0 Page 36 of 59 RSAC-6 INPUT 20160121 08:05 0
1 2
3 4
5 6
7 123456789012345678901234567890123456789012345678901234567890 1234567890123456789
- Line replaced by WinRp to use temporary external file src 1.txt
- 2002,C:\\Users\\dthorne\\Documnents\\Rsac*Input Files\\Krypton_2016.txt 2002,srcl.txt 2999
- F Stability and 2 mn/s 5000,0 500 1,2.,22.86,400.,1240.,0.,0 51l01,800.,900.,1000.,1 100.,1200.,1300.,1400.,1500.
5201,1.389E-4,0.
5400,2,0.,0.,0 5410,3,6,0 5999
- Dose Data 7000,0,-2, 1,0,1 7001,3.47E-04,0.,0,0,1.
7999
- Cloud Gamma 9000,0,0.
10000 0
1 2
3 4
5 6
7 123456789012345678901234567890 1234567890123456789012345678901234567890123456789
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 R ev. 2 Rev. 0 Page 37 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:05 PAGE 1
- Krypton MHA Analysis
- D~IRECT RADIONUCLIIDE IN~PUT ANY PREVIOUS INVENTORY HAS BEEN ZEROED NUCLIDE HALF LIFE CURIES 360831 Kr83m 1.830E+00 hi 9.650E+02 360850 Kr85 1.076E+01 yr 2.980E+I01 360851 Kr 85m 4.480E+I01 h 2.360E+I03 360870 Kr87 7.630E+01 m 2.120E+02 360880 Kr 88 2.840E+I00 h 3.180E+03
- METEOROLOGICAL DATA MEAN WIND SPEED = 2.000E+00 (m/s) STACK HEIGHT = 2.286E+01 (in)
MIXING LAYER HEIGHT =4.000E+02 (mn)
AIR DENSITY = l.240E+03 (g/cu mn)
WET DEPOSITION SCAVENGING COEFFICIENT =0.000E+00 (I/S)
NO CORRECTION IS BEING MADE FOR PLUME DEPLETION BY FALLOUT DEFAULT DRY DEPOSITION VELOCITIES (m/s)
SOLIDS -- 0.000E+00 HALOGENS = 0.000E+00 NOBLE GASES = 0.000E+00 CESIUM = 0.000E+00 RUTHENIUM = 0.000E+00 THERE ISi1 SET OF LEAKAGE CONSTANTS (K1,K2) 1.389E-04 0.000E+00 PASQUILL CLASS F METEOROLOGY, P-G SIGMA VALUES ENHANCED DEPOSITION PARAMETERS PARTICLE DIAMETER = 0.000E+00 (in) PARTICLE DENSITY = 0.000E+00 (g/cm3)
DOWNWIND DISTANCE STACK.SIGY SIGZ CHI/Q HEIGHT (in)
(in)
(in)
(s/cu m) 8.000E+02 2.286E+01 3.022E+01 1.175E+01 6.754E-05 DOWNWIND DISTANCE STACK SIGY SIGZ CHIIQ HEIGHT (mn) (mn)
(mn)
(s/cu mn) 9.000E+02 2.286E+01 3.361E+0 1 1.285E+0 1 7.574E-05
TEM-9002 09129109 Rev. 0 ENGINEERING DESIGN FILE ED F-3 124-0003 Rev. 2 Page 38 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:05 PAGE 2
- Kryton MHA Analysis DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(mn) 1.000E+03 2.286E+01 3.697E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 1.100E+I03 2.286E+01 4.029E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(mn)
(mn) 1.200E+03 2.286E+I01 4.359E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 1.300E+03 2.286E+01 4.685E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 1.400E+03 2.286E+01 5.010E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(mn) 1.500E+03 2.286E+01 5.332E+01 SIGY SIGZ CHI/Q (s/cu m) l.399E+01 8.094E-05 SIGY SIGZ CHI/Q (s/cu m) 1.507E+0 1 8.294E-05 SIGY SIGZ CHI/Q (s/cu mn) 1.607E+01 8.263E-05 SIGY SIGZ CHI/IQ (s/cu mn) 1.70 1E+01 8.095E-05 SIGY SIGZ CHI/Q (s/cu mn) 1.789E+01 7.85 1E-05 SIGY SIGZ CHI/Q (s/cu m) 1.872E+01 7.566E-05
- INHALATION DOSE EQUIVALENT CALCULATION USING DOSE CONVERSION FACTORS FROM FEDERAL GUIDANCE REPORT 11 RESPIRABLE FRACTION = 1.000E+-00 BREATHING RATE = 3.470E-04 (cu m/s)
RELEASE TIME FOR EXPONENTIAL DECAY FUNCTION = 7.1 99E+03 (s)
INTERNAL EXPOSURE TIME PERIOD =5.000E+01 (yr)
PARTICLE SIZE = 1.0 MICRON AMAD LUNG DEPOSITION FRACTIONS: N-P = 0.300 T-B = 0.080 P =0.250 DEFAULT ELEMENT LUNG CLEARANCE CLASSES SELECTED TO GIVE MAXIMUM DOSE
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 39 of 59 RADIOLOGICAL SAF7ETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIMVE 08:05 PAGE 3
- Krypton MHA Analysis DOWNWIND DISTANCE = 8.000E+02 (in)
PLUME TRAVEL TIME = 4.000E+02 (s)
CHI/Q = 6.754E-05 (s/cu m)
DOWNWIND DISTANCE = 9.000E+02 (in)
PLUME TRAVEL TIME = 4.500E+02 (s)
CHI/Q = 7.574E-05 (s/cu m)
DOWNWIND DISTANCE = 1.000E+03 (mn) PLUME TRAVEL TIME = 5.000E+02 (s)
CHI/Q =8.094E-05 (s/cu mn)
DOWNWIND DISTANCE = 1.100E+03 (mn) PLUME TRAVEL TIME = 5.500E+02 (s)
CHI/Q = 8.2 94E-05 (s/cu mn)
DOWNWIND DISTANCE = 1.200E+f03 (in)
PLUME TRAVEL TIME = 6.000E+02 (s)
CHI/Q =8.263E-05 (s/cu m)
DOWNWIND DISTANCE = 1.300E+03 (in)
PLUME TRAVEL TlIME -- 6.500E+I02 (s)
CI{IQ = 8.095E-05 (s/cu mn)
DOWNWIND DISTANCE = 1.400E+03 (mn) PLUME TRAVEL TIME = 7.000E+02 (s)
CHIL/Q = 7.851lE-05 (s/cu in)
DOWNWIND DISTANCE = 1.500E+03 (in)
PLUME TRAVEL TIME = 7.500E-H)2 (s)
CHI/Q = 7.566E-05 (s/cu mn)
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 40 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIMvE 08:05 PAGE 4
- Krypton MHA Analysis INHALATION COMMLTFED DOSE EQUIVALENTS ORDERED BY ORGAN (remn)
DOWNWIND DISTANCES (in)
ORGAN NO. 8.00E+02 9.00E+02 1.00E+03 1.10E+I03 1.20E+03 1.30E+03 1.40E+03 1.50E+-03 LUNGS 1 2.76E-02 3.1lE-02 3.34E-02 3.44E-02 3.44E-02 3.38E-02 3.28E3-02 3.17E-02 S WALL 2
1.16E-02 1.3 1E-02 1.40E-02 1.44E-02 1.44E-02 1.42E-02 1.38E-02 1.33E-02 SI WALL 3 3.04E-04 3.43E-04 3.68E3-04 3.79E-04 3.79E-04 3.73E-04 3.63E-04 3.51E-04 ULI WALL 4 3.71E-04 4.18E-04 4.50E-04 4.63E-04 4.64]3-04 4.57E-04 4.45E-04 4.31E-04 LUI WALL 5 4.69E-04 5.30E-04 5.70E-04 5.88E-04 5.89E-04 5.81E-04 5.67E-04 5.50E-04 TESTES 6 2.35E3-04 2.65E-04 2.84E3-04 2.92E-04 2.92E-04 2.87E-04 2.80E-04 2.70E-04 BREASTS 7 2.77E-04 3.12E-04 3.35E-04 3.44E-04 3.44E-04 3.38E-04 3.29E-04 3.18E-04 BONE SUP. 8 2.82E-04 3.17E-04 3.41E3-04 3.50E3-04 3.50E-04 3.44E-04 3.35E-04 3.24E-04 RMAIRROW 9 2.84E-04 3.20E-04 3.43E-04 3.53E-04 3.53E3-04 3.47E-04 3.38E-04 3.26E-04 THYROID 10 2.61E-04 2.94E-04 3.15E-04 3.24E-04 3.24E-04 3.18E3-04 3.10E-04 2.99E-04 KIDNEYS 11 2.78E-04 3.13E-04 3.36E-04 3.46E-04 3.46E-04 3.40E-04 3.31E-04 3.20E-04 LIVER 12 3.10E-04 3.50E3-04 3.75E-04 3.86E-04 3.86E-04 3.80E-04 3.69E-04 3.57E-04 SPLEEN 13 3.37E-04 3.80E-04 4.08E-04 4.19E-04 4.19E-04 4.12E-04 4.01E-04 3.88E-04 PANCREAS 14 3.87E3-04 4.361E-04 4.68E3-04 4.82E3-04 4.82E3-04 4.74E-04 4.61E-04 4.46E-04 MUSCLE 15 2.77E-04 3.12E-04 3.35E-04 3.44E-04 3.44E-04 3.38E-04 3.29E-04 3.18E-04 SKIN 16 2.47E-04 2.78E-04 2.99E-04 3.07E-04 3.07E-04 3.02E-04 2.94E3-04 2.84E-04 BRAIN 17 2.3 1E-04 2.60E-04 2.79E-04 2.87E-04 2.87E-04 2.82E-04 2.74E-04 2.65E-04 THIYMVUS 18 3.49E-04 3.94E-04 4.23E-04 4.35E-04 4.35E-04 4.27E-04 4.16E-04 4.02E-04 BL WALL 19 2.48E-04 2.80E-04 3.00E-04 3.09E-04 3.09E-04 3.04E-04 2.95E-04 2.86E-04 ADRENALS 20 3.03E3-04 3.42E-04 3.67E-04 3.77E-04 3.77E-04 3.71E-04 3.61E-04 3.49E-04 ESOPHAGU 21 3.49E3-04 3.94E-04 4.23E-04 4.35E-04 4.35E-04 4.27E-04 4.16E-04 4.02E-04 OVARIES 22 2.82E-04 3.18E-04 3.41E-04 3.52E-04 3.52E-04 3.46E-04 3.37E-04 3.26E-04 UTERUS 23 2.62E-04 2.95E-04 3.16E-04 3.26E-04 3.26E-04 3.20E-04 3.12E-04 3.01E-04
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09/29109 Rev. 2 Rev. 0 Page 41 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11102) SERIAL 1 DATE 20160120 TIME 08:05 PAGE 5
DOWNWIN4D DISTANCES (in)
ORGAN NO. 8.00E+02 9.00E+02 1.00E+03 1.10E+03 1.20E+I03 1.30E+03 1.40E+I03 1.50E+03 LUNGS 1 2.76E-02 3.11E-02 3.34E-02 3.44E-02 3.44E-02 3.38E-02 3.28E-02 3.17E-02 S WALL 2 1.16E-02 1.31E-02 1.40E-02 1.44E-02 1.44E-02 1.42E-02 l.38E-02 1.33E-02 LLI WALL 5 4.69E-04 5.30E-04 5.70E-04 5.88E-04 5.89E-04 5.81E-04 5.67E-04 5.50E-04 PANCREAS 14 3.87E-04 4.36E-04 4.68E-04 4.82E-04 4.82E-04 4.74E-04 4.61lE-04 4.46E-04 ULI WALL 4 3.71E-04 4.18E-04 4.50E-04 4.63E-04 4.64E-04 4.57E-04 4.45E-04 4.3 1E-04 THYMVUS 18 3.49E-04 3.94E-04 4.23E-04 4.35E-04 4.35E-04 4.27E-04 4.16E-04 4.02E-04 ESOPI{AGU 21 3.49E-04 3.94E-04 4.23E-04 4.35E-04 4.35E-04 4.27E-04 4.16E-04 4.02E-04 SPLEEN 13 3.37E-04 3.80E-04 4.08E-04 4.19E-04 4.19E-04 4.12E-04 4.01E-04 3.88E-04 LIVER 12 3.10E-04 3.50E.-04 3.75E-04 3.86E-04 3.86E-04 3.80E-04 3.69E-04 3.57E-04 SI WALL 3 3.04E-04 3.43E-04 3.68E-04 3.79E-04 3.79E-04 3.73E-04 3.63E-04 3.5 1E-04 ADRENALS 20 3.03E-04 3.42E-04 3.67E-04 3.77E-04 3.77E-04 3.71E-04 3.61E-04 3.49E-04 RMARIROW 9 2.84E-04 3.20E-04 3.43E-04 3.53E-04 3.53E-04 3.47E-04 3.38E-04 3.26E-04 OVARIES 22 2.82E-04 3.18E-04 3.41E-04 3.52E-04 3.52E-04 3.46E-04 3.37E-04 3.26E-04 BONE SUR. 8 2.82E-04 3.17E-04 3.41E-04 3.50E-04 3.50E-04 3.44E-04 3.35E-04 3.24E-04 KIDNEYS 11 2.78E-04 3.13E-04 3.36E-04 3.46E-04 3.46E-04 3.40E-04 3.31E-04 3.20E-04 BREASTS 7 2.77E-04 3.12E-04 3.35E-04 3.44E-04 3.44E-04 3.38E-04 3.29E-04 3.18E-04 MUSCLE 15 2.77E-04 3.12E-04 3.35E-04 3.44E-04 3.44E-04 3.38E-04 3.29E-04 3.18E-04 UTERUS 23 2.62E-04 2.95E-04 3.16E-04 3.26E-04 3.26E-04 3.20E-04 3.12E-04 3.01E-04 THIYROID 10 2.61E-04 2.94E-04 3.15E-04 3.24E-04 3.24E-04 3.18E-04 3.10E-04 2.99E-04 BL WALL 19 2.48E-04 2.80E-04 3.00E-04 3.09E-04 3.09E-04 3.04E-04 2.95E-04 2.86E-04 SKIN 16 2.47E-04 2.78E-04 2.99E-04 3.07E-04 3.07E-04 3.02E-04 2.94E-04 2.84E-04 TESTES 6 2.35E-04 2.65E-04 2.84E-04 2.92E-04 2.92E-04 2.87E-04 2.80E-04 2.70E-04 BRAIN 17 2.31lE-04 2.60E-04 2.79E-04 2.87E-04 2.87E-04 2.82E-04 2.74E-04 2.65E-04
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09/29109 Rev. 2 Rev. 0 Page 42 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:05 PAGE 6
- Krypton MIHA Analysis INHALATION WEIGHTED COMMITTED DOSE EQUIVALENTS (remn)
DOWNWIND DISTANCES (in)
ORGAN NO. 8.00E+02 9.00E+02 1.00E+03 1.10E+03 1.20E+03 1.30E+03 1.40E+03 1.50E+03 LUNGS 1 3.32E-03 3.74E-03 4.01E-03 4.12E-03 4.12E-03 4.05E-03 3.94E-03 3.81E-03 S WALL 2 6.97E-04 7.85E-04 8.43E-04 8.67E-04 8.67E-04 8.52E-04 8.29E-04 8.01E-04 SI WALL 3 1.82E-05 2.06E-05 2.21E-05 2.27E-05 2.28E-05 2.24E-05 2.18E-05 2.11E-05 ULI WALL 4 2.22E-05 2.51lE-05 2.70E-05 2.78E-05 2.78E-05 2.74E-05 2.67E-05 2.59E-05 LLI WALL 5 2.81E-05 3.18E-05 3.42E-05 3.53E-05 3.54E-05 3.49E-05 3.40E-05 3.30E-05 TESTES 6 5.88E-05 6.62E-05 7.10E-05 7.31E-05 7.31E-05 7.18E-05 6.99E-05 6.75E-05 BREASTS 7 4.15E-05 4.68E-05 5.02E-05 5.16E-05 5.16E-05 5.08E-05 4.94E-05 4.77E-05 BONE STIR 8 8.45E-06 9.52E-06 1.02E-05 1.05E-05 1.05E-05 1.03E-05 1.01E-05 9.71E-06 RMIVARROW 9 3.40E-05 3.84E-05 4.12E-05 4.24E-05 4.24E-05 4.16E-05 4.05E-05 3.92E-05 THYROID 10 7.82E-06 8.81E-06 9.45E-06 9.72E-06 9.72E-06 9.55E-06 9.29E-06 8.98E-06 K]DNEYS 11 1.67E-05 1.88E-05 2.02E-05 2.07E-05 2.07E-05 2.04E-05 1.98E-05 1.92E-05 LIVER 12 1.86E-05 2.10E-05 2.25E-05 2.32E-05 2.32E-05 2.28E-05 2.22E-05 2.14E-05 SPLEEN 13 2.02E-05 2.28E-05 2.45E-05 2.52E-05 2.52E-05 2.47E-05 2.41E-05 2.33E-05 PANCREAS 14 2.32E-05 2.62E-05 2.81E-05 2.89E-05 2.89E-05 2.84E-05 2.77E-05 2.67E-05 MUSCLE 15 1.66E-05 1.87E-05 2.01E-05 2.07E-05 2.07E-05 2.03E-05 1.98E-05 1.91E-05 SKIN 16 2.47E-06 2.78E-06 2.99E-06 3.07E-06 3.07E-06 3.02E-06 2.94E-06 2.84E-06 BRAIN 17 1.38E-05 1.56E-05 1.67E-05 1.72E-05 1.72E-05 1.69E-05 1.64E-05 1.59E-05 TIIYMVUS 18 2.10E-05 2.36E-05 2.54E-05 2.61E-05 2.61E-05 2.56E-05 2.50E-05 2.41E-05 BL WALL 19 1.49E-05 1.68E-05 1.80E-05 1.85E-05 1.85E-05 1.82E-05 1.77E-05 1.71E-05 ADRENALS 20 1.82E-05 2.05E-05 2.20E-05 2.26E-05 2.26E-05 2.23E-05 2.17E-05 2.09E-05 ESOPIIAGU 21 2.10E-05 2.36E-05 2.54E-05 2.61E-05 2.61E-05 2.56E-05 2.50E-05 2.41E-05 OVARIES 22 7.05E-05 7.95E-05 8.54E-05 8.79E-05 8.79E-05 8.65E-05 8.42E-05 8.15E-05 UTERUS 23 1.57E-05 1.77E-05 1.90E-05 1.95E-05 1.95E-05 1.92E-05 1.87E-05 1.81E-05 CEDE 24 4.28E-03 4.82E-03 5.17E-03 5.32E-03 5.32E-03 5.23E-03 5.09E-03 4.92E-03
- GAMMA~ DOSE CALCULATION WITH EXPOSURE TIME = 7.1994E+03 (s)
CALCULATIONS MADE USING THE FINITE MODEL EXTERNAL EDE DOWNWIND DISTANCE = 8.000E+02 (in)
DOSE =2.73E-02 (rem)
DOWNWIND DISTANCE = 9.000E+02 (in)
DOSE-- 2.60E-02 (remn)
DOWNWIND DISTANCE = 1.000E+03 (in)
DOSE = 2.50E-02 (remn)
DOWNWIND DISTANCE = 1.100E+I03 (in)
DOSE = 2.40E-02 (remn)
DOWNWIND DISTANCE = 1.200E+03 (in)
DOSE =2.30E-02 (remn)
DOWNWIND DISTANCE = 1.300E+I03 (in)
DOSE =2.2 1E.-02 (rem)
DOWNWIND DISTANCE = 1.400E+03 (in)
DOE=21E0(rm DOSE = 2.12E-02 (rem)
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 43 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)"
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIMvE 08:05 PAGE 7
- Krypton MIA Analysis DOWNWINJD DISTANCE = 1.500E+03 (In)
DOSE = 2.03E-02 (rem)
EXECUTION time = 2.80E-01 SECONDS
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 44 of 59 RSAC-6 INPUT 20160121 07:58 0
1 2
3 4
5 6
7 123456789012345678901234567890123456789012345678901234567890 1234567890123456789
- Xenon MH-A Analysis
- Line replaced by WinRp to use temporary external file src 1.txt
- 2002,C:\\Users\\dthorne\\Documents\\Rsac\\Input Files\\Xenon_.2016.txt 2002,srcl.txt 2999
- F Stability and 2 rn/s 5000,0 5001,2.,22.86,400.,1240.,0.,0 5101, 10., 100.,200.,300.,430.,500.,600.,700.
5201,1.389E-4,0.
5400,2,0.,0.,0 5410,3,6,0 5999
- Dose Data 7000,0, -2,1,0,1 700 1,3.47E..04,0.,0,0,1.
7999
- Cloud Ganmma 9000,0,0.
10000 0
1 2
3 4
5 6
7 12345678901234567890123456789012345678901234567890 12345678901234567890123456789
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 45 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 07:58 PAGE 1
- Xenon MHA Analysis
- DlRECT RADIONUCLIDE INPUT ANY PREVIOUS INVENTORY HAS BEEN ZEROED NUJCLIDE HALF LIFE CURIES 541311 Xe131m 1.184E+01 d 1.840E+02 541330 Xe133 5.243E+00 d 4.030E+04 541331 Xe133m 2.190E+00 d 1.190E+l03 541350 Xe135 9.140E+00 h 3.020E+I04 541351 Xe135m 1.529E+01 m 2.810E+03
- METEOROLOGICAL DATA MEAN WIND SPEED = 2.000E+00 (mis) STACK HEIGHT = 2.286E+01 (in)
MIXING LAYER HEIGHT = 4.000E+02 (mn)
AIR DENSITY = 1.240E+03 (g/cu m)
WET DEPOSiTION SCAVENGING COEFFICIENT = 0.000E+00 (1/S)
NO CORRECTION IS BEING MADE FOR PLUME DEPLETION BY FALLOUT DEFAULT DRY DEPOSITION VELOCITIES (mis)
SOLIDS = 0.000E+00 HALOGENS =0.000E+00 NOBLE GASES =O.000E+00 CESIUM = 0.000E+00 RUTHENIUM =0.000E+-00 THERE IS 1 SET OF LEAKAGE CONSTANTS (K1,K2) 1.389E-04 0.000E+00 PASQUJILL CLASS F METEOROLOGY, P-G SIGMA VALUES WARNING - DIFFUSION FOR DISTANCES OF LESS THAN 100 METERS IS EXTRAPOLATED ENHANCED DEPOSITION PARAMETERS PARTICLE DIAMETER = 0.000E+00 (in) PARTICLE DENSITY = 0.000E+00 (g/cm3)
DOWNWIND DISTANCE STACK SIGY SIGZ CHIIQ HEIGHT (in)
(in)
(in)
(s/cu in) 1.000E+0 1 2.286E+0 1 5.776E-0 1 3.454E-0 1 0.000E+00 DOWNWIND DISTANCE STACK SIGY SIGZ CHI/Q HEIGHT (in)
(In)
(In)
(s/cu in) 1.O00E+02 2.286E+01 4.621E+00 2.247E+I00 5.171E-25
TEM-9002 09/29109 Rev. 0 ENGINEERING DESIGN FILE EDF-3124-0003 Rev. 2 Page 46 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 07:58 PAGE 2
- Xenon MiHA Analysis DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 2.000E+02 2.286E+0-1 8.642E+00 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 3.000E+I02 2.286E+01 1.246E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 4.300E+02 2.286E+01 1.725E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(mn) 5.000E+02 2.286E+01 1.977E+0I DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 6.000E+02 2.286E+01 2.331E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 7.000E+02 2.286E+01 2.679E+01 SIGY SIGZ CHJJQ (s/cu mn) 3.988E+00 3.376E-10 SIGY SIGZ CHIIQ (s/cu in) 5.506E+00 4.185E-07 SIGY SIGZ CHIIQ (s/cu mn) 7.293E+00 9.302E-06 SIGY SIGZ CHIIQ (s/cu in) 8.195E+00 2.008E-05 SIGY SIGZ CHI/Q (s/cu mn) 9.430E+00 3.834E-05 SIGY SIGZ CHIIQ (s/cu in) 1.061E+01 5.500E-05
- INHALATION DOSE EQUIVALENT CALCULATION USING DOSE CONVERSION FACTORS FROM FEDERAL GUIDANCE REPORT 11 RESPIRABLE FRACTION = 1.000E+f00 BREATHING RATE = 3.470E-04 (cu m/s)
RELEASE TIME FOR EXPONENTIAL DECAY FUNCTION = 7.199E+03 (s)
INTERNAL EXPOSURE TlIME PERIOD =5.000E+01 (yr)
PARTICLE SIZE =1.0 MICRON AMAD LUNG DEPOSITION FRACTIONS: N-P = 0.300 T-B = 0.080 P = 0.250 DEFAULT ELEMENT LUNG CLEARANCE CLASSES SELECTED TO GIVE MAXIMUM DOSE
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 47 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 07:58 PAGE 3
- Xenon MHA Analysis DOWNWIND DISTANCE =1.000E+01 (in)
PLUME TRAVEL TIME = 5.000E+00 (s)
CIIIQ =0.000E+00 (s/cu in)
DOWNWIND DISTANCE = 1.000E+02 (mn) PLUME TRAVEL TIME = 5.000E+01 (s)
CHIIQ = 5.171E-25 (s/cu mn)
DOWNWIND DISTANCE = 2.000E+02 (in)
PLUME TRAVEL TIME -- 1.000E+02 (s)
CHI/Q = 3.376E-10 (s/cu in)
DOWNWIND DISTANCE = 3.000E+02 (in)
PLUME TRAVEL TIME = 1.500E+02 (s)
CHIIQ = 4. 185E-07 (s/cu in)
DOWNWIND DISTANCE = 4.300E+02 (in)
PLUME TRAVEL TIME = 2.150E+02 (s)
CHI/IQ = 9.302E-06 (s/cu in)
DOWNWIND DISTANCE = 5.000E+02 (in)
PLUME TRAVEL TIME = 2.500E+02 (s)
CHI/Q =2.008E-05 (s/cu in)
DOWNWIND DISTANCE = 6.000E+02 (in)
PLUME TRAVEL TIME = 3.000E+02 (s)
CI{JQ = 3.83 4E-05 (s/cu in)
DOWNWIND DISTANCE = 7.000E+02 (in)
PLUME TRAVEL TIME = 3.500E+02 (s)
CHIIQ = 5.500E-05 (s/cu in)
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 48 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIMvE 07:58 PAGE 4
DOWNWIND DISTANCES (in)
ORGAN NO. 1.00E+0l 1.00E+02 2.00E+I02 3.00E+02 4.30E+02 5.00E+02 6.00E+02 7.00E+I02 LUNGS 1 0.00E+00 9.39E-31 6.21E-16 7.80E-13 1.76E-11 3.84E-11 7.42E-11 1.08E-10 S WALL 2 0.00E+00 8.06E-31 5.33E-16 6.69E-13 1.51E-11 3.30E-11 6.37E-11 9,25E-11 SIWALL 3 0.00E+i00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 ULI WALL 4 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 LLIWALL 5 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 TESTES 6 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 BREASTS 7 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 BONE SUR 8 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 RMIARROW 9 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 THYROID 10 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 KIDNEYS 11 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 LIVER 12 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 SPLEEN 13 0.00E+0-0 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 PANCREAS 14 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 MUSCLE 15 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-il 6.32E-11 9.18E-11 SKIN 16 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 THYMUS 18 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 BLWALL 19 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 ADRENALS 20 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 ESOPHAGU 21 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 OVARIES 22 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 UTERUS 23 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 ORGANS WITH NO CALCULATED DOSE HAVE BEEN SUPPRESSED FROM TABLE
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 49 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-.6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIMiE 07:58 PAGE 5
DOWNWIND DISTANCES (in)
ORGAN NO. 1.00E+01 1.00E+02 2.00E+I02 3.00E+02 4.30E+I02 5.00E+02 6.00E+02 7.00E+02 LUNGS 1 0.00E+00 9.39E-31 6.21E-16 7.80E-13 1.76E-11 3.84E-11 7.42E-11 1.08E-10 S WALL 2 0.00E+I00 8.06E-31 5.33E-16 6.69E-13 1.51lE-11 3.30E-11 6.37E-11 9.25E-l1 SIWALL 3 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-1l ULIWALL 4 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-ll LLIWALL 5 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-ll TESTES 6 0.00E+0-0 7.99E-31 5.29E-16 6.64E-13 i.50E-11 3.27E-li 6.32E-11 9.18E-11 BREASTS 7 0.00E+i00 7.99E-31 5.29E-16 6.64E-13 l.50E-l1 3.27E-11 6.32E-11 9.18E-1l BONE SUR 8 0.00E+00 7.99E-31 5.29E-16 6.64E-13 l.50E-l1 3.2WE-il 6.32E-li 9.18E-1l RMARROW 9 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-l1 6.32E-11 9.18E-ll THYROID 10 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-li 6.32E-11 9.18E-ll KIDNEYS 11 0.00E+00 7.99E-31 5.29E-16 6.64E-13 l.50E-11 3.27E-li 6.32E-11 9.18E-l1 LIVER 12 0.00E+00 7.99E-31 5.29E-16 6.64E-13 l.50E-11 3.2WE-li 6.32E-11 9.18E-11 SPLEEN 13 0.00E+00 7.99E-31 5.29E-16 6.64E-13 i.50E-11 3.27E-l1 6.32E-I1 9.18E-II PANCREAS 14 0.00E+00 7.99E-31 5.29E-i6 6.64E-13 i.50E-11 3.2WE-il 6.32E-1l 9.18E-1i MUSCLE 15 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-il 6.32E-1i 9.18E-11 SKIN 16 0.00E+00 7.99E-31 5.29E-16 6.64E-i3 1.50E-li 3.27E-11 6.32E-11 9.18E-11 THYMVUS 18 0.00E+I00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-1i 6.32E-i1 9.i8E-11 BLWALL 19 0.00E+0-0 7.99E-31 5.29E-16 6.64E-i3 1.50E-11 3.27E-li 6.32E-i1 9.i8E-11 ADRENALS 20 0.00E+0-0 7.99E-31 5.29E-16 6.64E-i3 1.50E-11 3.2WE-1i 6.32E-i1 9.18E-11 ESOPIIAGU 21 0.00E+00 7.99E-3i 5.29E-16 6.64E-13 1.50E-1i 3.2WE-li 6.32E-i1 9.18E-11 OVARIES 22 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.i8E-11 UTERUS 23 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-l1 3.2WE-1l 6.32E-11 9.18E-ll ORGANS WITH NO CALCULATED DOSE HAVE BEEN SUPPRESSED FROM TABLE
TEM-9002 ENGI NEERI NG DESIG N FI LE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 50 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC.-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 07:58 PAGE 6
- XenonMHA Analysis INHALATION WEIGHTED COMMITTED DOSE EQUIVALENTS (rem)
DOWNWIND DISTANCES (in)
ORGAN NO. 1.00E+01 1.00E+I02 2.00E+I02 3.00E+02 4.30E+02 5.00E+02 6.00E+02 7.00E+02 LUNGS 1 0.00E+00 1.13E-31 7.45E-17 9.36E-14 2.12E-12 4.61E-12 8.91E-12 1.29E-11 S WALL 2 0.00E+00 4.83E-32 3.20E-17 4.02E-14 9.08E-13 1.98E-12 3.82E-12 5.55E-12 UI WALL 4 0.00E+00 4.79E-32 3.17E-17 3.98E-14 9.00E-13 1.96E-12 3.79E-12 5.51E-12 LLI WALL 5 0.00E+00 4.79E-32 3.17E-17 3.98E-14 9.00E-13 1.96E-12 3.79E-12 5.51E-12 TESTES 6 0.00E+00 2.00E-31 1.32E-16 1.66E-13 3.75E-12 8.17E-12 1.58E-11 2.29E-11 BREASTS 7 0.00E+00 1.20E-31 7.93E-17 9.96E-14 2.25E-12 4.90E-12 9.48E-12 1.38E-11 BONE SUR 8 0.00E+I00 2.40E-32 1.59E-17 1.99E-14 4.50E-13 9.80E-13 1.90E-12 2.75E-12 RMARROW 9 0.00E+00 9.59E-32 6.34E-17 7.97E-14 1.80E-12 3.92E-12 7.58E-12 1.10E-11 THYROID 10 0.00E+0-0 2.40E-32 1.59E-17 1.99E-14 4.50E-13 9.80E-13 1.90E-12 2.75E-12 KID)NEYS 11 0.00E+00 4.79E-32 3.17E-17 3.98E-14 9.00E-13 1.96E-12 3.79E-12 5.51E-12 LIVER 12 0.00E+00 4.79E-32 3.17E-17 3.98E-14 9.00E-13 1.96E-12 3.79E-12 5.51E-12 SPLEEN 13 0.00E+00 4.79E-32 3.17E-17 3.98E-14 9.00E-13 1.96E-12 3.79E-12 5.51E-12 PANCREAS 14 0.00E+O0 4.79E-32 3.17E-17 3.98E-14 9.00E-13 1.96E-12 3.79E-12 5.51E-12 MUSCLE 15 0.00E+00 4.79E-32 3.17E-17 3.98E-14 9.00E-13 1.96E-12 3.79E-12 5.51lE-12 SKIN 16 0.00E+00 7.99E-33 5.29E-18 6.64E-15 1.50E-13 3.2'7E-13 6.32E-13 9.18E-13 THYMUS 18 0.00E+00 4.79E-32 3.17E-17 3.98E-14 9.00E-13 1.96E-12 3.79E-12 5.51E-12 BLWALL 19 0.00E+00 4.79E-32 3.17E-17 3.98E-14 9.00E-13 1.96E-12 3.79E-12 5.51E-12 ADRENALS 20 0.00E+00 4.79E-32 3.17E-17 3.98E-14 9.00E-13 1.96E-12 3.79E-12 5.51E-12 ESOPHAGU 21 0.00E+00 4.79E-32 3.17E-17 3.98E-14 9.00E-13 1.96E-12 3.79E-12 5.51E-12 OVARIES 22 0.00E+00 2.00E-31 1.32E-16 1.66E-13 3.75E-12 8.17E-12 1.58E-11 2.29E-11 UTERUS 23 0.00E+00 4.79E-32 3.17E-17 3.98E-14 9.00E-13 1.96E-12 3.79E-12 5.51E-12 CEDE 24 0.00E+00 8.19E-31 5.42E-16 6.80E-13 1.54E-11 3.35E-11 6.48E-11 9.41E-11 ORGANS WITH NO CALCULATED DOSE HAVE BEEN SUPPRESSED FROM TABLE
- GAMM DOSE CALCULATION WITH EXPOSURE TIME = 7.1994E+03 (s)
CALCULATIONS MADE USING THE FINITE MODEL EXTERNAL EDE DOWNWIND DISTANCE = 1.000E+01 (in)
DOSE -- 3.3 9E-02 (remn)
DOWNWIND DISTANCE = 1.000E+I02 (in)
DOSE = 6.54E-02 (rem)
DOWNW~IND DISTANCE = 2.O00E+02 (in)
DOSE = 6.30E-02 (rem)
DOWNWIND DISTANCE = 3.000E+02 (in)
DOSE -- 5.97E-02 (rem)
DOWNWIND DISTANCE = 4.300E+-02 (in)
DOSE = 5.65E-02 (rem)
DOWNWIND DISTANCE = 5.000E+02 (in)
DOWNWIND DISTANCE = 6.000E+02 (in)
DOSE = 5.34E-02 (rem)
DOWNWIND DISTANCE = 7.000E+02 (in)
DOE=52E2(rm DOSE = 5.12E-02 (rein)
TEM-9002 09129109 Rev. 0 ENGINEERING DESIGN FILE EDF-3124-0003 Rev. 2 Page 51 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC--6, REV 6.2, 03/11102) SERIAL 1 DATE 20160120 TIME 07:58 PAGE 7
- Xenon MITA Analysis EXECUTION time = 2.80E-01 SECONDS
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 52 of 59 RSAC-6 INPUT 20160121 08:01 0
1 2
3 4
5 6
7 123456789012345678901234567890123456789012345678901234567890 1234567890123456789
- Line replaced by WinRp to use temporary external fie srcl.txt
- 2002,C:\\Users\\dtliome\\Documents\\Rsac\\Input Files\\Xenon_2016.txt 2002,srcl.txt 2999
- F Stability and 2 m/s 5000,0 500 1,2.,22.86,400., 1240.,0.,0 5 101,800.,900., 1000., 1 100., 1200., 1300., 1400., 1500.
5201,1.389E-4,0.
5400,2,0.,0.,0 5410,3,6,0 5999
- Dose Data 7000,0, -2,1,0,1 7001,3.47E-04,0.,0,0,1.
7999
- Cloud Gamma 9000,0,0.
10000 0
1 2
3 4
5 6
7 123456789012345678901234567890123456789012345678901234567890 1234567890123456789
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129/09 Rev. 2 Rev. 0 Page 53 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:01 PAGE 1
- XenonMI-IA Analysis
- DIiRECT RADIONUCLIDE INPUT ANY PREVIOUS INVENTORY HAS BEEN ZEROED NUCLIDE HALF LIF~E CURIES 541311 Xel31m 1.184E+01 d l.840E+02 541330 Xe133 5.243E+00 d 4.030E+04 541331 Xel33m 2.190E+00 d 1.190E+03 541350 Xe135 9.140E+00 h 3.020E+04 541351 Xel35m 1.529E+01 m 2.810E+03
- METEOROLOGICAL DATA MEAN WIND SPEED = 2.000E+00 (m/s) STACK HEIGHT = 2.286E+01 (in)
MIXING LAYER HEIGHT =4.000E+02 (in)
AIR DENSITY =1.240E+03 (g/cu m)
WET DEPOSITION SCAVENGING COEFFICIENT = 0.000E+00 (l/S)
NO CORRECTION IS BEING MADE FOR PLUME DEPLETION BY FALLOUT DEFAULT DRY DEPOSITION VELOCITIES (mis)
SOLIDS = 0.000E+0-0 HALOGENS = 0.000E+00 NOBLE GASES = 0.000E+00 CESIUM = 0.000E+00 RUTHENIUM = 0.000E+-00 THERE IS 1 SET OF LEAKAGE CONSTANTS (K1,K2) 1.389E-04 0.000E+00 PASQUILL CLASS F METEOROLOGY, P-G SIGMA VALUES ENHANCED DEPOSITION PARAMETERS PARTICLE DIAMETER =0.000E-I00 (in) PARTICLE DENSITY = 0.000E+00 (g/cm3)
DOWNWIND DISTANCE STACK SIGY SIGZ CHIIQ H-EIGHT (mn) (in)
(in)
(s/cu m) 8.000E+02 2.286E+01O 3.022E+01 1.175E+01 6.754E-05 DOWNWIND DISTANCE STACK SIGY SIGZ CHI/Q HEIGHT (in)
(in)
(in)
(s/cu m) 9.000E+02 2.286E+0 1 3.361E+0 1 1.285E+01 7.574E-05
TEM-9002 09129109 Rev. 0 ENGINEERING DESIGN FILE ED F-3 124-0003 Rev. 2 Page 54 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:01 PAGE 2
- Xenon MHA Analysis DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(mn) 1.000E+i03 2.286E+01O 3.697E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 1.100E+I03 2.286E+I01 4.029E+0l DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 1.200E+03 2.286E+01 4.359E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 1.300E+03 2.286E+01 4.685E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 1.400E+03 2.286E+01 5.0l0E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 1.500E+03 2.286E+01 5.332E+01 SIGY SIGZ CHI/Q (s/cu m) 1.399E+01 8.094E-05 SIGY SIGZ CHI/Q (s/cu mn) 1.507E+01I 8.294E-05 SIGY SIGZ CHI/Q (s/cu m) 1.607E+01 8.263E-05 SIGY SIGZ CHUiQ (s/cu mn) 1.701E+01O 8.095E-05 SIGY SIGZ CHIIQ (s/cu in) 1.789E+01 7.851E-05 SIGY SIGZ CHI-/Q (s/cu In) 1.872E+01 7.566E-05
- INHAL.ATION DOSE EQUIVALENT CALCULATION USING DOSE CONVERSION FACTORS FROM FEDERAL GUIDANCE REPORT 11 RESPIRABLE FRACTION = 1.000E+00 BREATHING RATE =3.470E-04 (cu mis)
RELEASE TIME FOR EXPONENTIAL DECAY FUNCTION = 7.199E+03 (s)
INTERNAL EXPOSURE TIME PERIOD = 5.000E+01 (yr)
PARTICLE SIZE = 1.0 MICRON AMAD LUNG DEPOSITION FRACTIONS: N-P = 0.300 T-B = 0.080 P = 0.250 DEFAULT ELEMENT LUNG CLEARANCE CLASSES SELECTED TO GIVE MAXIMUM DOSE
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 55 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC..6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIMvE 08:0 1PAGE 3
- Xenon MHA Analysis DOWNWIND DISTANCE = 8.000E+02 (in)
PLUME TRAVEL TIME = 4.000E+f02 (s)
CHI/Q = 6.754E-05 (s/cu mn)
DOWNWIND DISTANCE = 9.000E+02 (in)
PLUME TRAVEL TIME = 4.500E+02 (s)
CHI/Q =7.574E-05 (s/cu m)
DOWNWIND DISTANCE = 1.000E+03 (in)
PLUME TRAVEL TIME = 5.000E+02 (s)
CHII/Q = 8.0 94E-05 (s/cu in)
DOWNWIND DISTANCE = 1. 100E+03 (in)
PLUME TRAVEL TIME = 5.500E+02 (s)
CHIIQ = 8.294E-05 (s/cu in)
DOWNWIND DISTANCE = 1.200E+03 (in)
PLUME TRAVEL TIME = 6.000E+02 (s)
CHI/IQ = 8.263E-05 (s/cu in)
DOWNWIND DISTANCE = 1.300E+03 (in)
PLUME TRAVEL TIME = 6.500E+-02 (s)
CJHIIQ = 8.095E-05 (s/cu m)
DOWNWIh4D DISTANCE = 1.400E+03 (in)
PLUME TRAVEL TIME = 7.000E+02 (s)
CHI!Q = 7.851lE-05 (s/cu in)
DOWNWIND DISTANCE = 1.500E+03 (in)
PLUME TRAVEL TIME = 7.500E+02 (s)
CHI/Q = 7.566E-05 (s/cu in)
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 56 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:01 PAGE 4
- Xenon MEA Analysis INHALATION COMMUTIED DOSE EQUIVALENTS ORDERED BY ORGAN (rem)
DOWNWIND DISTANCES (in)
ORGAN NO. 8.00E+02 9.00E+02 1.00E+03 1.10E+03 1.20E+03 1.30E+03 1.40E+l03 1.50E+03 LUNGS 1 1.34E-10 1.52E-10 1.65E-10 1.71E-10 1.72E-10 1.70E-10 1.67E-10 1.63E-10 S WALL 2 L.15E-10 1.31IE-10 1.41E-10 1.46E-10 1.48E-10 1.46E-10 1.43E-10 1.40E-10 SI WALL 3 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-l0 ULIWALL 4 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 l.45E-10 1.42E-10 1.39E-10 LLI WALL 5 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 TESTES 6 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 BREASTS 7 l.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-l0 1.39E-10 BONE SUR 8 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 RMARROW 9 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 THYROID 10 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 KIDNEYS 11 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 LIVER 12 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 SPLEEN 13 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 PANCREAS 14 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 MUSCLE 15 1.14E-10 1L29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 I.39E-10 SKJN 16 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 THYMUS 18 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 BL WALL 19 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 ADRENALS 20 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-I0 1.39E-10 ESOPHAGU 21 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 OVARIES 22 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 UTERUS 23 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 ORGANS WITH NO CALCULATED DOSE HAVE BEEN SUPPRESSED FROM TABLE
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129/09 Rev. 2 Rev. 0 Page 57 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:01 PAGE 5
- XenonMHA Analysis INHALATION COMMITLTED DOSE EQUIVALENCES ORDERED BYDOSE (rem)
DOWNWIND DISTANCES (in)
ORGAN NO. 8.00E+f02 9.00E+02 1.00E+03 1.10E+03 l.20E+03 1.30E+03 1.40E+03 1.50E+03 LUNGS 1 1.34E-10 1.52E-10 1.65E-10 1.71E-10 1.72E-10 l.70E-10 1.67E-10 1.63E-10 S WALL 2 1.15E-10 1.31E-10 1.41E-10 1.46E-10 1.48E-10 1.46E-10 1.43E-10 1.40E-10 SIWALL 3 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 ULIWALL 4 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 LLIWALL 5 1.14E-l0 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 TESTES 6 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 BREASTS 7 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 BONE SUR 8 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 RMARROW 9 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 THYROID 10 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-l0 1.42E-10 1.39E-10 KIDNEYS 11 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 LIVER 12 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 SPLEEN 13 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 PANCREAS 14 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 MUSCLE 15 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 SKIN 16 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 TITYMUS 18 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-l0 BLWALL 19 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-l0 ADRENALS 20 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 ESOPHAGU 21 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 OVARIES 22 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 UTERUS 23 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 ORGANS WITH NO CALCULATED DOSE HAVE BEEN SUPPRESSED FROM TABLE
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 58 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:01 PAGE 6
DOWNWIND DISTANCES (in)
ORGAN NO. 8.00E+02 9.00E+02 1.00E+03 1.10E+03 1.20E+03 1.30E+03 1.40E+03 1.50E+03 LUNGS 1 1.61E-11 1.83E-11 1.97E-11 2.05E-11 2.06E-11 2.04E-11 2.01E-11 1.95E-11 S WALL 2 6.90E-12 7.83E-12 8.47E-12 8.78E-12 8.85E-12 8.77E-12 8.60E-12 8.39E-12 SIWALL 3 6.84E-12 7.77E-12 8.40E-12 8.71E-12 8.78E-12 8.70E-12 8.53E-12 8.32E-12 ULI WALL 4 6.84E-12 7.77E-12 8.40E-12 8.71E-12 8.78E-12 8.70E-12 8.53E-12 8.32E-12 LUIWALL 5 6.84E-12 7.77E-12 8.40E-12 8.71E-12 8.78E-12 8.70E-12 8.53E-12 8.32E-12 TESTES 6 2.85E-11 3.24E-11 3.50E-11 3.63E-11 3.66E-11 3.62E-11 3.56E-11 3.47E-11 BREASTS 7 1.71E-11 1.94E-11 2.10E-11 2.18E-11 2.19E-11 2.17E-11 2.13E-11 2.08E-11 BONE SUR 8 3.42E-12 3.88E-12 4.20E-12 4.36E-12 4.39E-12 4.35E-12 4.27E-12 4.16E3-12 RMARROW 9 1.37E-11 1.55E-11 1.68E-11 1.74E-11 1.76E-11 1.74E-11 1.71E-11 1.66E-11 THYROID 10 3.42E-12 3.88E-12 4.20E-12 4.36E-12 4.39E-12 4.35E-12 4.27E-12 4.16E-12 KIDNEYS 11 6.84E-12 7.77E-12 8.40E-12 8.71E-12 8.78E-12 8.70E-12 8.53E-12 8.32E-12 LIVER 12 6.84E-12 7.77E-12 8.40E-12 8.71E-12 8.78E-12 8.70E-12 8.53E-12 8.32E-12 SPLEEN 13 6.84E-12 7.77E-12 8.40E-12 8.71E-12 8.78E-12 8.70E-12 8.53E-12 8.32E-12 PANCREAS 14 6.84E-12 7.77E-12 8.40E-12 8.71E-12 8.78E-12 8.70E-12 8.53E-12 8.32E-12 MUSCLE 15 6.84E-12 7.77E-12 8.40E-12 8.71E-12 8.78E-12 8.70E-12 8.53E-12 8.32E-12 SKIN 16 1.14E-12 1.29E-12 1.40E-12 I.45E-12 1.46E-12 1.45E-12 1.42E-12 1.39E-12 THYMUS 18 6.84E-12 7.77E-12 8.40E-12 8.71E-12 8.78E-12 8.70E-12 8.53E-12 8.32E-12 BL WALL 19 6.84E-12 7.77E-12 8.40E-12 8.71E-12 8.78E-12 8.70E-12 8.53E-12 8.32E-12 ADRENALS 20 6.84E-12 7.77E-12 8.40E-12 8.71E-12 8.78E-12 8.70E-12 8.53E-12 8.32E-12 ESOPIIAGU 21 6.84E-12 7.77E-12 8.40E-12 8.71E-12 8.78E-12 8.70E-12 8.53E-12 8.32E-12 OVARIES 22 2.85E-11 3.24E-11 3.50E-11 3.63E-11 3.66E-11 3.62E-11 3.56E-11 3.47E-11 UTERUS 23 6.84E-12 7.77E-12 8.40E-12 8.71E-12 8.78E-12 8.70E-12 8.53E-12 8.32E-12 CEDE 24 1.17E-10 1.33E-10 1.44E-10 1.49E-10 1.50E-10 1.49E-10 1.46E-10 1.42E-10 ORGANS WITH NO CALCULATED DOSE HAVE BEEN SUPPRESSED FROM TABLE
- GAMMA DOSE CALCULATION WITH EXPOSUR~E TIME = 7.1994E+03 (s)
CALCULATIONS MADE USING THE FINITE MODEL EXTERNAL EDE DOWNWIND DISTANCE = 8.000E+02 (in)
DOSE = 4.88E-02 (rem)
DOWNWIND DISTANCE =9.000E+02 (mn)
DOSE = 4.65E-02 (rem)
DOWNWIND DISTANCE =1.000E+I03 (mn)
DOSE = 4.47E-02 (rem)
DOWNWIND DISTANCE= 1.100E+03 (in)
DOSE = 4.28E-02 (rem)
DOWNWIND DISTANCE =l.200E+03 (in)
DOSE = 4.11E-02 (rem)
DOWNWIND DISTANCE =.300E+03 (mn)
DOSE = 3.94E-02 (rem)
DOWNWIND DISTANCE =.400E+03 (mn)
DOSE = 3.79E-02 (rein)
DOWNWIND DISTANCE =1.500E+03 (mn)
DOE=36E0(e)
DOSE = 3.63E-02 (rem)
TEM-9002 09129109 Rev. 0 ENGINEERING DESIGN FILE EDF-3124-0003 Rev. 2 Page 59 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIMVE 08:01 PAGE 7
- Xenon MHA Analysis EXECUTION time = 2.80E-01 SECONDS
- NW MI
~a'S*~f^~SOO*
NWMI-201 6-RAI-001 Rev. 0 Appendix G -
EDF-3124-0003, Preliminary Maximum Hypothetical Accident to Support the Northwest Medical Isotope Facility Environmental Report G-i
Document ID:
EDF-3124-0003 Revision ID: 2 Effective Date: 1/21/16 Engineering Design File Preliminary Maximum Hypothetical Accident to Support the Northwest Medical Isotopes Facility Environmental Report Portage Project No.: 3124 Project
Title:
NWMI Environmental Report 4Portage TEM-9002 09/29/09 Rev. 0
TEM-9002 09129109 Rev. 0
- 1. Portage Project No.:
3124 ENGINEERING DESIGN FILE EDF-3124-0003 Rev. 2 Page 1 of 59
- 2. Proj ect/Task:
NWMI Environmental Report
- 3. DCN#
4.
Title:
Preliminary Maximum Hypothetical Accident to Support the Northwest Medical Isotopes Facility Environmental Report
- 5. NPHI PC or SDC: N/A
- 6. SSC Safety Category: N/A 7
Sunumary: The Radiological Safety Analysis Computer (RSAC) code, Version 6.2, was used to develop the preliminary maximum hypothetical accident (MHilA) for the Northwest Medical Isotopes, LLC (NWMVII Radioisotope Production Facility (RPF). The worst-case accident is considered preliminary and is based on the RPF preliminary hazards analysis (NWMvI-2015-SAFETY 001) and NWMI's preliminary design for the RPF prepared in support of the Construction Penmit Application submitted in 2015.
The MH-A consists of a fitre-related gross failure of the target dissolution offgas treatment system that releases all radioiodine and noble gas radioisotopes retained in that system out the RPF stack without mitigation.
The inventory for the MHA is based on a set of initial conditions that were designed to maximize the potential source term and bound the credible scenanios.
The results of the modeling show that for a 22.9 m (75-ift) stack with the release detailed above, the maximum dose received during a two-hour exposure by an individual would be a total effective dose equivalent (TEDE) of --22.6 remn (as compared to 17.1 remn in Chapter 19) at a distance of 1,100 in. The TEDE to the public located outside at the controlled area would be from 3.6 mSv (0.36 rem) at the nearest fence line 10 m (30 if) to 7 mSv (0.70 remn) at the furthest fence line 91 m (300 if). The TEDE to the nearest resident located 430 m away was calculated to be 31 mSv (3.1 rem). The highest TEDE to the licensee staff outside the building would be 7 mSv (0.70 rem) for a person located 91 m (300 if) from the location of the stack. The TEDE doses are greater than the limits of 10 CFR 20, "Standards for Protection Against Radiation." However, 10 CRF 20 limits are for normal operations not accident situations. The TEDE indicates that the maximum hypothetical accident (MiHA) is the intermediate consequence event per 10 CFR 70.61, "Performance Requirements."
8 Distribution: (Portage, Inc.)
9 Review (Rk) and Approval (A) Signatutres:
(Identify minimum reviews and approvals. 'Additional reviews/approvals may be added.)
~~Printed Name/
RIA Organization Signature..
Date..:,
Author/Design Agent A
Dave Thome
- 1/21/16 Independent Review R
Michel Hall
]7*
1/21/16 Independent Review R
,Project Manager R/A John Beller
- 1/21/16 Registered Professional Engineer's Stamp (if required)
[] N/A
TEM-9002 ENGINEERING DESIGN FIlE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 2 of 59 Contents
- 1.
Introduction................................................................................................... 4
- 2.
Radiological Safety Analysis Computer Overview..............
- ......................................... 4
- 3.
Dissolution Offgas System.................................................................................. 5
- 4.
Maximum Hypothetical Accident Scenario and Source Term........................................... 7
- 5.
Model Parameters and Assumptions....................................................................... 8
- 6.
Model Results................................................................................................ 8
- 7.
References................................................................................................... 11 Attachment - RSAC Output.................................................................................... 12 Figures Figure 1.
Target Dissolution Flow Diagram............................................................... 5 Figure 2.
Iodine Removal System.......................................................................... 6 Figure 3.
Total Effective Dose Equivalent (Inhalation plus External) for 2-Hour Ground Level Exposure from Maximum Hypothetical Accident.................................... 10 Tables Table 1.
Iodine Removal Units Source Terms for the Maximum Hypothetical Accident............ 7 Table 2.
Maximum Hypothetical Accident Inhalation Committed Effective Dose Equivalent......................................................................................... 9 Table 3.
Maximum Hypothetical Accident External Cloud Gamma Dose............................ 9 Table 4.
Maximum Hypothetical Accident Total Effective Dose Equivalent........................ 10
TEM-9002 09129/09 Rev. 0
.ENGINEERING DESIGN FILE EDF-31 24-0003 Rev. 2 Page 3 of 59 This page intentionally left blank.
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 4 of 59
- 1.
INTRODUCTION The Radiological Safety Analysis Computer (RSAC) code, Version 6.2 (RSAC-6.2), was used to ensure that the doses to the public detennine if the dose rate requirements in Title 10, Code of Federal Regulations, Subpart 100.11 (10 CFR 100.11), "Determination of Exclusion Area, Low Population Zone, and Population Center Distance," would drive the required size of the exclusion area boundary for the Northwest Medical Isotopes, LLC (NWMvI) Radioisotope Production Facility (RPF). 10 CFR 100.11 requires that an exclusion area be sized so that an individual located at any point on its boundary for 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> immediately following onset of the postulated fission product release would not receive a total radiation dose to the whole body in excess of 25 rem roentgen equivalent in man (rem). The worst-case accident is considered preliminary and is based on the RPF Preliminary Hazards Analysis(NWMI-20 15-SAFETY-00 1), and facility preliminary design completed in support of the Construction Permit Application submitted to the U.S. Nuclear Regulatory Commission (NRC) (NWMVI-2013-021, Rev. 0).
The preliminary worst-case accident is identified to be a release of the accumulated radionuclides in the offgas system that results in the loss of the fission gas retention system. The associated preliminary analysis was completed to determine the bounding dose to an individual given in total effective dose equivalent (TEDE) at various distances from the release point.
RSAC-6.2 was developed in 1973 by Idaho National Laboratory and is still used today for modeling complex accidents and radiological consequences to individuals from the release of radionuclides to the atmosphere. A user can generate a fission product inventory; decay and ingrowth of the inventory during transport through processes, facilities, and the environment; model the downwind dispersion of the activity; and calculate doses to downwind individuals (INL/EXT-05 -00642, RSAC 6.2 with WinRP 2.0:
User Manual). Doses are calculated through the inhalation and cloud gamma exposure pathways.
- 2.
RADIOLOGICAL SAFETY ANALYSIS COMPUTER OVERVIEW A fission product inventory can be calculated in RSAC from the reactor operating history or to simulate a nuclear criticality accident. Radionuclide inventories can also be directly input into RSAC. Source term modeling allows for complete progeny ingrowth and decay during all accident phases. Release scenario modeling allows fractionation of the inventory by chemical group or element. The effects of high-efficiency particulate air (HIEPA) filters or other cleanup systems can be modeled. RSAC calculates meteorological dispersion in the atmosphere using Gaussian plume diffusion for the Pasquill-Gifford, Hilmeier-Gifford, and Markee models. A unique capability is the ability to model Class F fumigation conditions, the meteorological condition that causes the highest ground level concentrations from an elevated release.
Doses may be calculated for various pathways, including inhalation, ingestion, ground-surface, air immersion, and water immersion pathways. Dose calculations may be made for either acute or chronic releases. RSAC-6.2 calculates inhalation doses using the International Commission on Radiation Protection (ICRP) Publication 30, Limits for Intakes of Radionuc lides by Workers (1979) model, with dose conversion factors (DCF) from EPA-520 1/1-88-020, Limiting Values of Radionuc lide Intake and Air Concentration and Dose Conversion Factors for Inhalation, Submersion, and Ingestion. The committed dose equivalent (CDE) is calculated for individual organs and tissues over a 50-year period after inhalation. The CDE for each organ or tissue is multiplied by the appropriate ICRP Publication 26, Recommendations of the ICRP (1977) weighting factor and then summed to calculate the committed effective dose equivalent (CEDE).
The RSAC-6.2 gamma dose from the cloud (in which the person may or may not be immersed in the cloud depending on the plume position in relation to the ground surface) is the effective dose equivalent (EDE), which is the sum of the products of the dose equivalent to the organ or tissue and the weighting factors applicable to each of the body organs or tissues that are irradiated.
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09/29109 Rev. 2 Rev. 0 Page 5 of 59 The sunmnation of the two RSAC-6.2 doses is the total effective dose equivalent (TEDE), which is the sum of the EDE (for external exposures) and the CEDE (for inhalation exposures). The RSAC-6.2 dose calculations and dose terminology are consistent with NRC 10 CFR 20, "Standards for Protection Against Radiation" terminology, based on ICRP Publications 26 and 30.
- 3.
DISSOLUTION OFFGAS SYSTEM Target disassembly and dissolution of irradiated LEU target results in gaseous fission products (iodine [1],
xenon [Xe], and krypton [Kr]) with very high radiation levels. A primary function of the process offgas systems is to control release of these gases both within the facility and external to the facility. The dissolver offgas treatment system is divided into the nitrogen oxide (NOx) treatment and fission gas retention subsystems. The fission gas retention system removes isotopes of iodine from the offgas and retains noble gases (Xe and Kr) until they have decayed sufficiently to allow release. The primary function of the NOx treatment system is to treat the dissolver offgas so that it is suitable for discharge to the fission gas retention system.
The primary functions of the fission gas retention system are to remove the isotopes of iodine from the gas stream and to delay release of the noble gases (Xe and Kr) sufficiently to allow release to the stack.
The fission gas retention system also provides primary confinement of the gases to prevent their release within the facility. Figure 1 illustrates the target dissolution process.
[Proprietary Information]
Figure 1. Target Dissolution Flow Diagram Within the fission gas retention system, the iodine removal units ([RU) and the secondary absorbers are the primary unit operations responsible for retaining the iodine and fission product noble gases. The primary absorbers allows decay time for the short half-life noble gases to reduce the dose at the secondary treatment equipment. The system uses three parallel IRUs, as shown in Figure 2: one IIRU is for the target disassembly station, one for the dissolvers, and the third is an installed spare.
TEM-9002 09/29109 Rev. 0 ENGINEERING DESIGN FILE EDF-3124-0003 Rev. 2 Page 6 of 59
[Proprietary Information]
Figure 2.Iodine Removal System
TEM-9002 09129109 Rev. 0 ENGINEERING DESIGN FILE EDF-31 24-00 03 Rev. 2 Page 7 of 59
- 4.
MAXIMUM HYPOTHETICAL ACCIDENT SCENARIO AND SOURCE TERM The maximum hypothetical accident (MHA) consists of a fire-related gross failure of the target dissolution offgas treatment system that releases all radioiodine and noble gas radioisotopes retained in that system out the RPF stack without mitigation.
The evaluation of the inventory for the considered MVHA is based on a set of limiting initial conditions that were designed to maximize the potential source term and bound the credible scenarios. These assumptions include:
[Proprietary Information]
All iodine and noble gases in the targets released into the offgas system, and no iodine or noble gases captured in the nitrogen oxide (NOx) scrubbers or retained in the dissolver solution
[Proprietary Information]
Greater than expected release of material (e.g., the entire inventory of iodine is assumed to be deposited on a single IRU, no plating out of iodine, or subsequent capture downstream oflIRU)
The source term used in the MHIA is from NWMI-2013-CALC-01 1, Source Term Calculations. The breakdown of the radionuclide inventory used in NWMVI-2013-CALC-01 1 is extracted from NWMVI-2013-CALC-006, Overall Summary Material Balance - MURR Target Batch, using the reduced set of 123 radioisotopes. NWMI-2013-CALC-0 14, Selection of Dominant Target Isotopes for NWM[
Material Balances, identifies the 123 dominant radioisotopes included in the MUJRR material balance (NWMI-2013-CALC-006). NWMvI-2013-CALC-014 provides the basis for using the 123 radioisotopes from the total list of 660 radioisotopes potentially present in irradiated targets. The majority of omitted radioisotopes exist in trace quantities and/or decay swiftly to stable nuclides. The reduced set of 123 radioisotopes consists of those that dominate the radioactivity and decay heat of irradiated targets.
The bounding iodine and noble gas isotopic source terms used were taken from NWMIH-20 13 -CALC-0 11 and are summarized in Table 1.
Table 1. Iodine Removal Units Source Terms for the Maximum Hypothetical Accident 1291 1301
-132j 133I 133m I 134I Total curies =
3.67E-05 9.06E-0 1 1.70E+04 2.54E+04 3.32E+04
.,5.50E+00 3.39E+02 1.i72E+04/
',9.32E+04 83m*
8 5Kr 87Kr
- 9.65E+02 2.98E+01 2.12E+02
.131mXe 1 33rXe 135Xe 1.84E+02 4.03E+04 1.-1*l]9E+03)_
3.02E+04 2:
'.8 fE+03-6.75E44031 7.46E+04
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 8 of 59
- 5.
MODEL PARAMETERS AND ASSUMPTIONS The Radiological Safety Analysis Code (RSAC) system, RSAC Version 6.2, was used to model the dispersion resulting from the MH-A. The following common parameters were used for all model runs:
Release point: 22.9 meters (in) (75 feet [it])
Wind-speed: 2 m/second (s) (provides minimal mixing and dilution, considered conservative)
Source term per Table 1 Analysis of Class F stability characteristics (stable air, considered conservative)
No plume rise (i.e., buoyancy or stack momentum effects) accounted for in this model (limited mixing and dilution, conservative)
Mixing depth: 400 m used in the model (RSAC default)
Air density: 1,240 grams (g)/cubic meter (in3) used in the model Pasquill-Gifford Sigma values used in the model No plume depletion used (i.e., wet or dry deposition) 2-hr release assumed (i.e., constant release of all activity over this time period) 2-hr exposure assumed ICRP 30 model used for inhalation doses Finite cloud immersion model assumed Breathing rate: 3.47E-4 m3/s (i.e., ICRP 30 heavy activity value)
Respiratory fraction: 1 provides the RSAC output file for the MHA analyses.
- 6.
MODEL RESULTS The dose results for the MiHA inventory are provided in Table 2 through Table 4, and are illustrated in Figure 3. The results of the modeling show that for a 22.9 m (75-ft) stack with the release detailed above, the maximum dose received during a two-hour exposure by an individual would be a total effective dose equivalent (TEDE) of -22.6 rem (as compared to 17.1 rem in Chapter 19) at a distance of 1,100 m. The TEDE to the public located outside at the controlled area would be from 3.6 mSv (0.36 rem) at the nearest fence line 10 m (30 ft) to 7 mSv (0.70 rem) at the furthest fence line 91 m (300 fi). The TEDE to the nearest resident located 430 m away was calculated to be 31 mnSv (3.1 rem). The highest TEDE to the licensee staff outside the building would be 7 mSv (0.70 rem) for a person located 91 m (300 ft) from the location of the stack. The TEDE doses are greater than the limits of 10 CFR 20, "Standards for Protection Against Radiation." However, 10 CRF 20 limits are for normal operations not accident situations. The TEDE indicates that the maximum hypothetical accident (MHA) is the intermediate consequence event per 10 CFR 70.61, "Performance Requirements."
The calculated dose rates meet the 10 CFR 50.34, "Contents of Applications; Technical Information,"
requirements to ensure that (1) an individual located at any point on the boundary of the exclusion area for any 2-hr period following the onset of the postulated fission product release, would not receive a radiation dose in excess of 25 rem TEDE, and (2) an individual located at any point on the outer boundary of the low population zone, who is exposed to the radioactive cloud resulting from the postulated fission product release (during the entire period of its passage) would not receive a radiation dose in excess of 25 rem TEDE. The calculated dose rates for the MHA show that the MIHA is an intermediate consequence event per 10 CFR 70.61, "Performance Requirements."
TEM-9002 09129109 Rev. 0 ENGINEERING DESIGN FILE EDF-3124-0003 Rev. 2 Page 9 of 59 Table 2. Maximum Hypothetical Accident Inhalation Conmmitted Effective Dose Equivalent 100 200 300
- 4 3 0 b 500 7O00 800 900 1,100 1,100 1.500
- 1, 0.00E+00 1.38E-19
, 9.03E-05 S 1. 12E-0 1 2.49E+00 5.37E+00
-, : i 2" i'i'1.O2E+01i.
1.47E+01
- .............*80E+O1 2.02E+0 1 S2.2 1E+0 1
'/2.2,1E+01",
2.16E+01
~.
209E+0 1 2.02E+0 1
- ' 0.O0E+00.,
3.15E-23
- ,_2.07E-08[ [
2
...258E-05..
3,,, _5.79E-04,,,
1.25E-03 3.47E-03 4.28E-03 4.82E-03 5.1i::ii7E-03.:*~ii 5
5.32E-03
!.,532E-03:*::
5.23E-03 3:. 5:.09E-03 _
- 4.92E-03 0
,,.00E+-00 8.1 9E-3 1
... 5.42E-.16 S 6.80E-13
- ' 1.54E-11 S 3.35E-11
- 6/[.
[648E-11(
9.41E-11
- ,21.!17E-1!0_
1 1.33E-10 1?"
.......44....
1.49E-10 1II:.50E-l10 S 1.49E-10 1
].....46E-10 1.42E-10
, O.OOE+OO 1.3 8E-1 9
- ... 9.03E-05 1
.....12E-01
- ' 2.49E+00 5.37E+00
' 1.02E+*011 1.47E+01 1
...!80E+01.
S 2.02E+0 1 2.21E+01
',2;2'1E+.01 2.16E+01 2.20_9E+/-.01 2.02E+0 1 aDose at the nearest fence line, which is 10 nm b Nearest resident is located at 430 m.
Table 3. Maximum Hypothetical Accident External Cloud Gamma Dose I.
-]
- 200, 300 500 700
.. 7'800:
900 1,100
,1,300 1:i
,4007 1,500 3.1.0E-_01 i.88E]3-02,'
5.96E-01 3.60E-02
-7...5.75E-01 3.48E-02'-!
5.46E-01 3.31IE-02
-,+ 5.19E-0,1,,7-3.15E-02, 5.09E-01 3.09E-02 4.70E-01 2.86E-02
..4.48E-0_1......... 2.73E-O2...
4.26E-01 2.60E-02
.i.!
-, i-!i~ i 4. 09E-01 i*:"ii, :,.2.5.0E-052,,i[
3.92E-01 2.40E-02
" : ::....3.76E-0i1..... '... 2i30E-02,'
- 3.60E-01 2.21E-02
- 3. 45E-01..
2....
12_
E-02.
3.31E-01 2.03E-02
- 3.
339E-02_ -
6.54E-02 5.97E-02 5.65E-02 S 5.53E-02
- ,!:, -5.34E-02 '
S 5.12E-02
- -4.88E-02 4.65E-02 S 4.28E-02 S 3.94E-02 S 3.63E-02 3:63E-01 6.97E-01 6--
6.73E3 6.3 9E-0 1 6
.:607E-01 S 5.95E-01 i-i_' 57.74Et-E0i 5.50E-01 5.24E-01 4.99E-0 1 4.59E-0 1 4.22E-0 1
.-.' i04E-01....
3.88E-01
- 1 aDose at the nearest fence line, which is 10 1n.
b Nearest resident is located at 430 m.
TEM-9002 09129/09 Rev. 0 ENGINEERING DESIGN FILE EDF-31 24-0003 Rev. 2 Page 10 of 59 Table 4. Maximum Hypothetical Accident Total Effective Dose Equivalent j~a Is 100 300 500 600 700
(,, '"
, *800,
900 1,000;?
- oo 1,100 1
,200 1,300 b.,
- - 1,400 1,500
-*: 3.10E 5.96E-01 S 6.58E=01 5.88E+00 1.52E+01
! 2.06E+0 1 2.25E+01
,"2.25E+0 1 S 2.20E+0 1 S 2.05E+01 1..188E-02,
- 3.
039E-02, 3.60E-02 6.54E-02 3.48E02 6.0E-0 3.3 1E-02 5.97E-02 3.22E-02 5.53E-02
" -.. 3.23E-02'
...... '5.34E-02" S 3.21E-02 5.12E-02 3.08E-02 4.65E-02
,,,.02E-02
- 4.47E-02.
2.93E-02 4.28E=02
,....2:83EO2-0 4.11IE-02 2.73E-02 3.94E=02 2,
...,°263E-02 3"I}....379E--02...
2.52E--02 3.63E=02
",3.63E=01 S 6.97E-01 S 7.51E-01 3.:'
1:>ioE+600, 5.97E+00 S...1.08E+01-1.53E+01 2.07E+01 2.26E+01 2.20E+0 1
, 2.06E+01 a Dose at the nearest fence line, which is 10 in.
b Nearest resident is located at 430 m.
Figure 3 provides a graph of the model results based on the parameters described above. The stack provides the time and distance to disperse the plume prior to reaching the ground. The results show that a person within close proximity to the facility would receive almost no dose.
25 EP 20 15
- 0. 10 o
w-L.
0 0
200 400 600 800 1000 1200 1400 1600 Distance from Stack, meters Figure 3.Total Effective Dose Equivalent (Inhalation plus. External) for 2-Hour Ground Level Exposure from Maximum Hypothetical Accident
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 11 of 59
- 7.
REFERENCES 10 CFR 20, "Standards for Protection Against Radiation," Code of Federal Regulations, as amended.
10 CFR 50.34, "Contents of Applications; Technical Information," Code of Federal Regulations, as amended.
10 CFR 70.61, "Performance Requirements," Code of Federal Regulations, as amended.
10 CFR 100.11, "'Determination of Exclusion Area, Low Population Zone, and Population Center Distance," Code of Federal Regulations, as amended.
EPA-5201/1-88-020, Limiting Values of Radionuclide Intake and Air Concentration and Dose Conversion Factors for Inhalation, Submersion, and Ingestion, Federal Guidance Report No. 11, U.S. Environmental Protection Agency, Washington, D.C., 1988.
ICRP Publication 26, Recommendations of the ICRP, International Commission on Radiological Protection, Ottawa, Ontario, Canada, 1977.
ICRP Publication 30, Limits for Intakes of Radionuclides by Workers, Part 1, International Commission on Radiological Protection, Ottawa, Ontario, Canada, 1979.
INL/EXT-05-00642, RSAC 6.2 with WinRP 2.0: User Manual, Idaho National Laboratory, Idaho Fails, Idaho, 2005.
NWMI-2013-CALC-006, Overall Summary Material Balance - MURR Target Batch, Rev A, Northwest Medical Isotopes, LLC, Corvallis, Oregon, 2013.
NWMI-20 13-CALC-0 11, Source Term Calculations, Rev A, Northwest Medical Isotopes, LLC, Corvallis, Oregon, 2015.
NWMI-2014-CALC-0 14, Selection of Dominant Target Isotopes for NWMJ Material Balances, Rev A, Northwest Medical Isotopes, LLC, Corvallis, Oregon, 2014.
NWMVI-2015-SAFETY-001, Radioisotope Production Facility Preliminary Hazards Analysis, Rev. A, Northwest Medical Isotopes, LLC, Corvallis, Oregon, 2015.
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-O003 09129109 Rev. 2 Rev. 0 Page 12 of 59 Radiological Safety Analysis Computer Code Output RSAC-6TINPUT 20160121 08:09 o
1 2
3 4
5 6
7 123456789012345678901234567890123456789012345678901234567890 1234567890123456789
- Iodine MH-A Inventory 2000,0
- Line replaced by WinRp to use temporary external file srcl.txt
- 2002,C:\\Users\\dthomne\\Documents\\,Rsac\\Input Files\\Iodine_2016.txt 2002,srcl.txt 2999
- F Stability and 2 rn/s 5000,0 5001,2.,22.86,400., 1240.,0.,0 5101, 10.,100.,200.,300.,430.,500.,600.,700.
5201, 1.389E-4,0.
5400,2,0.,0.,0 5410,3,6,0 5999
- Dose Data 7000,0,-2, 1,0,1 7001,3.47E-04,0.,0,0, 1.
7999
- Cloud Gamma 9000,0,0.
10000 0
1 2
3 4
5 6
7 123456789012345678901234567890123456789012345678901234567890 1234567890123456789
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 13 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:09 PAGE 1
- Iodine MIIA Analysis
- **DIRE~CT RADIONUJCLLDE INPUT ANY PREVIOUS INVENTORY HAS BEEN ZEROED NUCLIDE HALF LIFE CUIRIES 531290 1129 1.570E+07 yr 3.670E-05 531300 I130 1.236E+01 hi 9.060E-01 531310 1131 8.021E+00 d 1.700E+04 531320 1132 2.295E+00 h 2.540E+04 531330 1133 2.080E+01 h 3.320E+04 531331 1133m 9.000E+00 s 5.500E+00 531340 1134 5.250E+01 m 3.390E+02 531350 1135 6.570E+00 h 1.720E+04
- METEOROLOGICAL DATA MEAN WIND SPEED =2.000E+00 (nm/s)
STACK HEIGHT -- 2.286E+01 (in)
MIX[NG LAYER HEIGHT -- 4.000E+02 (in)
AIR DENSITY = 1.240E+03 (g/cu mn)
WET DEPOSITION SCAVENGING COEFFICIENT =0.000E+00 (1/S)
NO CORRECTION IS BEING MADE FOR PLUME DEPLETION BY FALLOUT DEFAULT DRY DEPOSITION VELOCITIES (m/s)
SOLIDS = 0.000E+0-0 HALOGENS = 0.000E+00 NOBLE GASES = 0.000E+00 CESIUM = 0.000E+00 RUTHENIUM =0.000E+00 THERE IS 1 SET OF LEAKAGE CONSTANTS (K1,K2) 1.389E-04 0.000E+-00 PASQUILL CLASS F METEOROLOGY, P-G SIGMA VALUES WARNING - DIFFUSION FOR DISTANCES OF LESS THAN 100 METERS IS EXTRAPOLATED ENHANCED DEPOSITION PARAMETERS PARTICLE DIAMETER = 0.000E+00 (mn) PARTICLE DENSITY -- 0.000E+00 (g/cm3)
DOWNWIND DISTANCE STACK SIGY SIGZ CHI/Q HEIGHT (in)
(mn)
(in)
(s/cu in) 1.000E+01 2.286E+01 5.776E-01 3.454E-01 0.000E+00
TEM-9002 09/29109 Rev. 0 ENGINEERING DESIGN FILE ED F-3124-0003 Rev. 2 Page 14 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/ll/02) SERIAL 1 DATE 20160120 TIME 08:09 PAGE 2
- Iodine MLIA Analysis DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) l.000E+f02 2.286E+01 4.621E+00 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 2.000E+02 2.286E+01 8.642E+00 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 3.000E+02 2.286E+01 1.246E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 4.300E+02 2.286E+01 1.725E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 5.000E+02 2.286E+01 I.977E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 6.000E+02 2.286E+01l 2.331E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 7.000E+-02 2.286E+01 2.679E+01 SIGY SIGZ CHIIQ (s/cu mn) 2.247E+00 5.171E-25 SIGY SIGZ CHI/Q (s/cu mn) 3.988E+00 3.376E-10 SIGY SIGZ CIII/Q (s/cu m) 5.506E+I00 4. 185E-07 SIGY SIGZ CHI/Q (s/cu in) 7.293E+00 9.302E-06 SIGY SIGZ CHI/Q (s/cu in) 8.195E+O0 2.008E-05 SIGY SIGZ CHI/Q (s/cu in) 9.430E+00 3.834E-05 SIGY SIGZ CHI/Q (s/cu in) 1.061lE+0 1 5.500E-05
- INHALATION DOSE EQUIVALENT CALCULATION USING DOSE CONVERSION FACTORS FROM FEDERAL GUIDANCE REPORT 11 RESPIRABLE FRACTION = 1.000E+-00 BREATHING RATE = 3.470E-04 (cu m/s)
RELEASE TIME FOR EXPONENTIAL DECAY FUNCTION = 7. 199E+03 (s)
INTERNAL EXPOSURE TIME PERIOD = 5.000E+0 1 (yr)
PARTICLE SIZE =1.0 MICRON AMAD LUNG DEPOSITION FRACTIONS: N-P = 0.300 T-B = 0.080 P = 0.250 DEFAULT ELEMENT LUNG CLEARANCE CLASSES SELECTED TO GIVE MAXIMUM DOSE
TEM-9002 ENGINEERING DESIGN FILE EDF-3124--0003 09129109 Rev. 2 Rev. 0 Page 15 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:09 PAGE 3
- Iodine MBA Analysis DOWNWIND DISTANCE = 1.000E+01 (in)
PLUME TRAVEL TIME = 5.000E+00 (s)
CHIIQ = 0.000E+00 (s/cu mn)
DOWNWIND DISTANCE = 1.000E+02 (in)
PLUME TRAVEL TIME = 5.000E+01 (s)
CHI/IQ= 5.171E-25 (s/cu mn)
DOWNWIND DISTANCE = 2.000E+02 (in)
PLUME TRAVEL TIME = 1.000E+02 (s)
CHIIQ = 3.376E-10 (s/cu in)
DOWNWIND DISTANCE = 3.000E+02 (in)
PLUME TRAVEL TIME = 1.500E+02 (s)
CHI/Q = 4. 185E-07 (s/cu in)
DOWNWIND DISTANCE = 4.300E+02 (in)
PLUME TRAVEL TIME = 2. 150E+02 (s)
CHI/IQ =9.3 02E-06 (s/cu in)
DOWNWIND DISTANCE = 5.000E+02 (in)
PLUME TRAVEL TIME = 2.500E+I02 (s)
CHIIQ = 2.008E-05 (s/cu in)
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 16 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:09 PAGE 4
- Iodine MHA Analysis DOWNWIND DISTANCE =6.000E+02 (in)
PLUME TRAVEL TIME = 3.000E+02 (s)
CI{IQ = 3.834E-05 (s/cu mn)
DOWNWIND DISTANCE = 7.000E+02 (in)
PLUME TRAVEL TIME = 3.500E+02 (s)
CHI/Q = 5.500E-05 (s/cu m)
INHALATION COMIMYFITE DOSE EQUIVALENTS ORDERED BY ORGAN (rem)
DOWNWIND DISTANCES (in)
ORGAN NO. 1.00E+01 1.00E+02 2.00E+02 3.00E+02 4.30E+02 5.00E+02 6.00E+02 7.00E+-02 LUNGS 1 0.00E+00 3.28E-20 2.14E-05 2.65E-02 5.89E-01 1.27E+00 2.42E+00 3.47E+I00 S WALL 2 0.00E+00 5.36E-21 3.50E-06 4.33E-03 9.60E-02 2.07E-01 3.95E-01 5.65E-01 SI WALL 3 0.00E+00 1.12E-21 7.30E-07 9.04E-04 2.01E-02 4.33E-02 8.26E-02 1.18E-01 ULI WALL 4 0.00E+00 1.13E-21 7.38E-07 9.13E-04 2.03E-02 4.37E-02 8.34E-02 1.20E-01 LLI WALL 5 0.00E+00 1.05E-21 6.88E-07 8.51E-04 1.89E-02 4.08E-02 7.78E-02 1.11E-01 TESTES 6 0.00E+0-0 9.58E-22 6.25E-07 7.74E-04 1.72E-02 3.71E-02 7.07E-02 1.01E-01 BREASTS 7 0.00E+00 1.93E-21 1.26E-06 1.56E-03 3.47E-02 7.48E-02 1.43E-01 2.05E-01 BONE SUR 8 0.00E+00 1.54E-21 1.01E-06 1.25E-03 2.77E-02 5.98E-02 1.14E-01 1.64E-01 RMAIRROW 9 0.00E+00 1.69E-21 1.10E-06 1.37E-03 3.03E-02 6.55E-02 1.25E-01 1.79E-01 THYROID 10 0.00E+0O0 4.43E-18 2.89E-03 3.58E+00 7.96E+01 1.72E+02 3.28E+I02 4.70E+02 KIDNEYS 11 0.00E+00 1.25E-21 8.17E-07 1.01E-03 2.25E-02 4.84E-02 9.24E-02 1.32E-01 LIVER 12 0.00E+00 1.57E-21 1.02E-06 1.27E-03 2.81E-02 6.07E-02 1.16E-01 1.66E-01 SPLEEN 13 0.00E+00 1.62E-21 1.05E-06 1.30E-03 2.89E-02 6.24E-02 1.19E-01 1.71E-01 PANCREAS 14 0.00E+00 1.81E-21 1.18E-06 1.46E-03 3.23E-02 6.98E-02 1.33E-01 1.91E-01 MUSCLE 15 0.00E+'00 1.93E-21 1.26E-06 1.56E-03 3.47E-02 7.48E-02 1.43E-01 2.05E-01 SKIN 16 0.00E+00 1.37E-21 8.93E-07 1.11E-03 2.46E-02 5.30E-02 1.01E-01 1.45E-01 THYMUS 18 0.00E+00 4.15E-21 2.71E-06 3.36E-03 7.46E-02 1.61E-01 3.07E-01 4.40E-01 BL WALL 19 0.00E+00 1.01E-21 6.61E-07 8.18E-04 1.82E-02 3.92E-02 7.48E-02 1.07E-01 ADRENALS 20 0.O0E+00 1.71E-21 1.12E-06 1.38E-03 3.07E-02 6.61E-02 1.26E-01 1.81E-01 ESOPHAGU 21 0.00E+00 4.15E-21 2.71E-06 3.36E-03 7.46E-02 1.61E-01 3.07E-01 4.40E-01 OVARIES 22 0.00E+0I0 9.97E-22 6.50E-07 8.05E-04 1.79E-02 3.85E-02 7.35E-02 1.05E-01 UTERUS 23 0.00E+00 1.06E-21 6.90E-07 8.54E-04 1.90E-02 4.09E-02 7.80E-02 1.12E-01 ORGANS WITH NO CALCULATED DOSE HAVE BEEN SUPPRESSED FROM TABLE
TEM-9002 ENGINEERING DESIGN FILE EDF-3124.-0003 09129109 Rev. 2 Rev. 0 Page 17 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC.-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:09 PAGE 5
DOWNWIND DISTANCES (in)
ORGAN NO. 1.00E+i01 1.00E+02 2.00E+02 3.00E+02 4.30E+02 5.00E+02 6.00E+I02 7.00E+02 LUNGS 1 0.00E+00 3.28E-20 2.14E-05 2.65E-02 5.89E-01 L.27E+00 2.42E+00 3.47E+00 S WALL 2 0.00E+00 5.36E-21 3.50E-06 4.33E-03 9.60E-02 2.07E-01 3.95E-01 5.65E-01 SIWALL 3 0.00E+00 1.12E-21 7.30E-07 9.04E-04 2.01E-02 4.33E-02 8.26E-02 1.18E-01 ULI WALL 4 0.00E+00 1.13E-21 7.38E-07 9.13E-04 2.03E-02 4.37E-02 8.34E-02 1.20E-01 LLI WALL 5 0.00E+00 1.05E-21 6.88E-07 8.51E-04 1.89E-02 4.08E-02 7.78E-02 1.11E-01 TESTES 6 0.00E+00 9.58E-22 6.25E-07 7.74E-04 1.72E-02 3.71E-02 7.07E-02 1.01E-01 BREASTS 7 0.00E+I00 1.93E-21 1.26E-06 1.56E-03 3.47E-02 7.48E-02 1.43E-01 2.05E-01 BONE SUR 8 0.00E+00 1.54E-21 1.01E-06 1.25E-03 2.77E-02 5.98E-02 1.14E-01 1.64E-01 RMARROW 9 0.00E+00 1.69E-21 1.10E-06 1.37E-03 3.03E-02 6.55E-02 1.25E-01 1.79E-01 THYROID 10 0.00E+00 4.43E-18 2.89E-03 3.58E+00 7.96E+01 1.72E+02 3.28E+02 4.70E+02 KTIDNEYS 11 0.00E+00 1.25E-21 8.17E-07 1.01E-03 2.25E-02 4.84E-02 9.24E-02 1.32E-01 LIVER 12 0.00E+00 1.57E-21 1.02E-06 1.27E-03 2.81E-02 6.07E-02 1.16E-01 1.66E-01 SPLEEN 13 0.00E+I00 1.62E-21 1.05E-06 1.30E-03 2.89E-02 6.24E-02 1.19E-01 1.71E-01 PANCREAS 14 0.00E+00 1.81E-21 1.18E-06 1.46E-03 3.23E-02 6.98E-02 1.33E-01 1.91E-01 MvUSCLE 15 0.00E+00 1.93E-21 1.26E-06 1.56E-03 3.47E-02 7.48E-02 1.43E-01 2.05E-01 SKIN 16 0.00E+00 1.37E-21 8.93E-07 1.11E-03 2.46E-02 5.30E-02 1.01E-01 1.45E-01 THIYMvUS 18 0.00E+00 4.15E-21 2.71E-06 3.36E-03 7.46E-02 1.61E-01 3.07E-01 4.40E-01 BLWALL 19 0.00E+I00 1.01E-21 6.61E-07 8.18E-04 1.82E-02 3.92E-02 7.48E-02 1.07E-01 ADRENALS 20 0.00E+00 1.71E-21 1.12E-06 1.38E-03 3.07E-02 6.61E-02 1.26E-01 1.81E-01 ESOPHAGU 21 0.00E+I00 4.15E-21 2.71E-06 3.36E-03 7.46E-02 1.61E-01 3.07E-01 4.40E-01 OVARIES 22 0.00E+00 9.97E-22 6.50E-07 8.05E-04 1.79E-02 3.85E-02 7.35E-02 1.05E-01 UTERUS 23 0.00E+00 1.06E-21 6.90E-07 8.54E-04 1.90E-02 4.09E-02 7.80E-02 1.12E-01 ORGANS WITH NO CALCULATED DOSE HAVE BEEN SUPPRESSED FROM TABLE
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 18 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIMVE 08:09 PAGE 6
- Iodine MIIA Analysis INHALATION WEIGHTED COMMVITTED DOSE EQUIVALENTS (rem)
DOWNWIND DISTANCES (in)
ORGAN NO. 1.00E+01 1.00E+02 2.00E+I02 3.00E+02 4.30E+02 5.00E+02 6.00E+02 7.00E+02 LUNGS 1 0.00E+00 3.94E-21 2.57E-06 3.18E-03 7.07E-02 1.52E-01 2.91E-01 4.17E-01 S WALL 2 0.00E+0-0 3.22E-22 2.10E-07 2.60E-04 5.76E-03 1.24E-02 2.37E-02 3.39E-02 SI WALL 3 0.00E+I00 6.72E-23 4.38E-08 5.43E-05 1.20E-03 2.60E-03 4.96E-03 7.10E-03 ULI WALL 4 0.00E+00 6.79E-23 4.43E-08 5.48E-05 1.22E-03 2.62E-03 5.01E-03 7.17E-03 LLI WALL 5 0.00E+00 6.32E-23 4.13E-08 5.11E-05 1.13E-03 2.45E-03 4.67E-03 6.69E-03 TESTES 6 0.00E+00 2.40E-22 1.56E-07 1.93E-04 4.29E-03 9.26E-03 1.77E-02 2.53E-02 BREASTS 7 0.00E+00 2.90E-22 1.89E-07 2.34E-04 5.20E-03 1.12E-02 2.14E-02 3.07E-02 BONE SUIR 8 0.00E+00 4.63E-23 3.02E-08 3.74E-05 8.32E-04 1.79E-03 3.42E-03 4.91E-03 RMARROW 9 0.00E+00 2.03E-22 1.32E-07 1.64E-04 3.64E-03 7.85E-03 1.50E-02 2.15E-02 THYROID 10 0.00E+00 1.33E-19 8.67E-05 1.07E-01 2.39E+00 5.15E+0-0 9.84E+00 1.41E+01 KIDNEYS 11 0.00E+00 '7.51E-23 4.90E-08 6.07E-.05 1.35E-03 2.91E-03 5.54E-03 7.94E-03 LIVER 12 0.00E+00 9.42E-23 6.14E-08 7.61E-05 1.69E-03 3.64E-03 6.95E-03 9.95E-03 SPLEEN 13 0.00E+00 9.69E-23 6.32E-08 7.83E-05 1.74E-03 3.75E-03 7.15E-03 1.02E-02 PANCREAS 14 0.00E+00 1.08E-22 7.06E-08 8.74E-05 1.94E-03 4.19E-03 7.98E-03 1.14E-02 MUSCLE 15 0.00E+00 1.16E-22 7.56E-08 9.37E-05 2.08E-03 4.49E-03 8.56E-03 1.23E-02 SKIN 16 0.00E+00 1.37E-23 8.93E-09 1.11E-05 2.46E-04 5.30E-04 1.01E-03 1.45E-03 THYMUS 18 0.00E+00 2.49E-22 1.63E-07 2.01E-04 4.48E-03 9.66E-03 l.84E-02 2.64E-02 BL WALL 19 0.00E+00 6.08E-23 3.97E-08 4.91E-05 1.09E-03 2.35E-03 4.49E-03 6.43E-03 ADRENALS 20 0.00E+00 1.03E-22 6.69E-08 8.29E-05 1.84E-03 3.97E-03 7.57E-03 1.08E-02 ESOPHAGU 21 0.00E+00 2.49E-22 1.63E-07 2.01E-04 4.48E-03 9.66E-03 1.84E-02 2.64E-02 OVARIES 22 0.00E+00 2.49E-22 1.62E-07 2.01E-04 4.47E-03 9.64E-03 1.84E-02 2.63E-02 UTERUS 23 0.00E+0-0 6.35E-23 4.14E-08 5.13E-05 1.14E-03 2.45E-03 4.68E-03 6.71E-03 CEDE 24 0.00E+00 1.38E-19 9.03E-05 1.12E-01 2.49E+00 5.37E+00 1.02E+I01 1.47E+01 ORGANS WITH NO CALCULATED DOSE HAVE BEEN SUPPRESSED FROM TABLE
- GAMMA DOSE CALCULATION WITH EXPOSURE TIME = 7.1994E+03 (s)
CALCULATIONS MADE USING THlE FINiTE MODEL EXTERNAL EDE DOWNWIND DISTANCE =l.000E+0l (in)
DOSE = 3.10E-01 (rem)
DOWNWIND DISTANCE = 1.000E+02 (mn)
DOSE = 5.96E-01 (rem)
DOWNWIND DISTANCE =2.000E+02 (mn)
DOSE = 5.75E-01 (rem)
DOWNWIND DISTANCE = 3.000E+02 (in)
DOSE = 5.46E-01 (rem)
DOWNWIND DISTANCE = 4.300E+02 (in)
DOSE = 5.19E-01 (rem)
DOWNWIND DISTANCE = 5.000E+02 (in)
DOSE = 5.09E-01 (remn)
DOWNWIND DISTANCE =6.000E+02 (in)
DOSE = 4.91E-01 (remn)
DOWNWIND DISTANCE = 7.000E+02 (in)
DOE=47E0(rm DOSE = 4.70E-01 (rein)
TEM-9002 09129109 Rev. 0 ENGINEERING DESIGN FILE EDF-3124-0003 Rev. 2 Page 19 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:09 PAGE 7
- Iodine MHA Analysis EXECUTION time =2.80E-01 SECONDS
TEM-9002 ENGINEERING DESIGN FILE EDF-31 24-0003 09/29/09 Rev. 2 Rev. 0 Page 20 of 59 RSAC-6IINPUJT 20160121 08:12 o
1 2
3 4
5 6
7 123456789012345678901234567890123456789012345678901234567890 1234567890123456789
- Iodine MVHA Analysis
- Iodine MBA Inventory 2000,0
- Line replaced by WinRp to use temporary external file src 1.txt
- 2002, C:\\Users\\dthorne\\Documents\\Rsac\\Input Files\\Iodine_20 16.txit 2002,srcl.txt 2999
- F Stability and 2 mis 5000,0 500 1,2.,22.86,400., 1240.,0.,0 5 101,800.,900.,1000.,1 100.,1200.,1300.,1400.,1500.
5201,1.389E-4,0.
5400,2,0.,0.,0 5410,3,6,0 5999
- Dose Data 7000,0, -2,1,0,1 700 1,3.47E-04,0.,0,0, 1.
7999
- Cloud Gaimna 9000,0,0.
10000 0
1 2
3 4
5 6
7 123456789012345678901234567890123456789012345678901234567890 1234567890123456789
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 21 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 T]EvIE8:12 PAGE 1
- Iodine MHA Analysis
- DIIRECT RADIONUCLIDE INPUT ANY PREVIOUS INVENTORY HAS BEEN ZEROED NUCLIDE HALF LIFE CURIES 531290 1129 1.570E+07 yr 3.670E-05 531300 1130 1.236E+l01 h 9.060E-01 531310 1131 8.021E+00 d 1.700E+04 531320 1132 2.295E+l00 h 2.540E+04 531330 1133 2.080E+01 h 3.320E+04 531331 1133m 9.000E+00 s 5.500E+00 531340 1134 5.250E+01 m 3.390E+I02 531350 1135 6.570E+00 h 1.720E+04
- METEOROLOGICAL DATA MEAN WIND SPEED = 2.000E+00 (mis) STACK HEIGHT = 2.286E+01 (in)
MIXING LAYER HEIGHT = 4.000E+02 (in)
AIR DENSITY -- 1.240E+03 (g/cu in)
WET DEPOSITION SCAVENGING COEFFICIENT = 0.000E+00 (l/S)
NO CORRECTION IS BEING MADE FOR PLUME DEPLETION BY FALLOUT DEFAULT DRY DEPOSITION VELOCITIES (mis)
SOLIDS = 0.000E+I00 HALOGENS = 0.000E+00 NOBLE GASES = 0.000E+00 CESIUM = 0.000E+00 RUTHENIUM = 0.000E+00 THERE ISi1 SET OF LEAKAGE CONSTANTS (K1,K2) 1.389E-04 0.000E+00 PASQUJILL CLASS F METEOROLOGY, P-G SIGMA VALUES ENHANCED DEPOSITION PARAMETERS PARTICLE DIAMETER = 0.000E+00 (in) PARTICLE DENSITY = 0.000E+00 (g/cm3)
DOWNWiND DISTANCE STACK SIGY SIGZ CH!IQ HEIGHT (in)
(in)
(in)
(s/cu in) 8.000E+02 2.286E+01 3.022E+01 1.175E+01 6.754E-05 DOWNWIND DISTANCE STACK SIGY SIGZ CHIIQ HEIGHT (mn) (mn)
(in)
(s/cu mn) 9.000E+02 2.286E+01 3.361E+01 1.285E+01 7.574E-05
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 22 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:12 PAGE 2
- Iodine MHA Analysis DOWNWIND DISTANCE STACK SIGY SIGZ CHJ!Q HIEIGHT (in)
(mn)
(in)
(s/cu in) 1.000E+I03 2.286E+01 3.697E+01 1.399E+01 8.094E-05 DOWNWIND DISTANCE STACK SIGY SIGZ CHI/Q HEIGHT (mn) (in)
(in)
(s/cu m) 1.100E+03 2.286E+01 4.029E+01 1.507E+01 8.294E-05 DOWNWIND DISTANCE STACK SIGY SIGZ CHIIQ HEIGHT (in)
(in)
(in)
(s/cu mn) 1.200E+I03 2.286E+01 4.359E+I01 1.607E+01 8.263E-05 DOWNWIND DISTANCE STACK SIGY SIGZ CHIIQ HEIGHT (in)
(in)
(mn)
(s/cu m) 1.300E+03 2.286E+01 4.685E+01 1.701E+01 8.095E-05 DOWNWIND DISTANCE STACK SIGY SIGZ CHIIQ HEIGHT (in)
(in)
(in)
(s/cu mn) 1.400E+0)3 2.286E+01 5.010E+01 1.789E+O1 7.851E-05 DOWNWIND DISTANCE STACK SIGY SIGZ CHIIQ HEIGHT (in)
(in)
(in)
(s/cu m) 1.500E+03 2.286E+01 5.332E+l01 1.872E+01 7.566E-05
- INHALATION DOSE EQUIVALENT CALCULATION USING DOSE CONVERSION FACTORS FROM FEDERAL GUIDANCE REPORT 11 RESPIRABLE FRACTION =.000E+00 BREATHING RATE = 3.470E-04 (cu m/s)
RELEASE TIME FOR EXPONENTIAL DECAY FUNCTION -- 7.199E+03 (s)
INTERNAL EXPOSURE TIME PERIOD =5.000E+0 1 (yr)
PARTICLE SIZE = 1.0 MICRON AMAD LUNG DEPOSITION FRACTIONS: N-P = 0.300 T-B = 0.080 P = 0.250 DEFAULT ELEMENT LUNG CLEARANCE CLASSES SELECTED TO GIVE MAXIMUM DOSE
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 23 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:12 PAGE 3
- Iodine MHA Analysis DOWNWIND DISTANCE = 8.O00E+02 (in)
PLUME TRAVEL TIME =4.O00E+02 (s)
CHI/Q =6.754E-05 (s/cu mn)
DOWNWIND DISTANCE = 9.000E+02 (In)
PLUME TRAVEL TIME = 4.500E+02 (s)
CHIIQ = 7.574E-05 (s/cu im)
DOWNWIND DISTANCE = 1.000E+03 (in)
PLUME TRAVEL TIME = 5.000E+i02 (s)
CHIIQ =8.094E-05 (s/cu in)
DOWNWIND DISTANCE = 1.100E+03 (in)
PLUME TRAVEL TIME = 5.500E+02 (s)
CHIIQ = 8.294E-05 (s/cu m)
DOWNWIND DISTANCE = 1.200E+03 (in)
PLUME TRAVEL TIME =6.000E+-02 (s)
CHIIQ =8.263E-05 (s/cu in)
DOWNWIND DISTANCE = 1.300OE+03 (in)
PLUME TRAVEL TIME = 6.500E+02 (s)
CHIIQ = 8.095E-05 (s/cu in)
DOWNWIND DISTANCE =1.400E+03 (in)
PLUME TRAVEL TIME = 7.000E+i02 (s)
CHIIQ = 7.85 1E-05 (s/cu in)
DOWNWIND DISTANCE = 1.500E+03 (in)
PLUME TRAVEL TIME = 7.500E+02 (s)
CHI/Q = 7.566E-05 (s/cu in)
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 24 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:12 PAGE 4
DOWNWIND DISTANCES (in)
ORGAN NO. 8.00E+02 9.00E+02 1.00E+03 1.10E+03 1.20E+l03 1.30E+03 1.40E+i03 1.50E+03 LUNGS 1 4.26E+0-0 4.77E+00 5.10E+00 5.22E+00 5.20E+00 5.09E+00 4.93E+00 4.74E+00 S WALL 2 6.93E-01 7.76E-01 8.28E-01 8.48E-01 8.43E-01 8.25E-01 7.99E-01 7.69E-01 SI WALL 3 1.45E-01 1.63E-01 1.74E-01 1.78E-01 1.77E-O1 1.73E-01 1.68E-01 1.61E-01 ULI WALL 4 1.47E-01 1.64E-01 1.75E-01 1.80E-01 1.79E-01 1.75E-01 1.69E-01 1.63E-01 LLIWALL 5 1.37E-01 1.53E-01 1.63E-01 1.67E-01 1.67E-01 1.63E-01 1.58E-O1 1.52E-01 TESTES 6 1.24E-01 1.39E-01 1.49E-01 1.52E-01 1.51E-01 1.48E-01 1.44E-01 1.38E-01 BREASTS 7 2.51E-01 2.81E-O1 3.00E-01 3.08E-01 3.06E-01 3.00E-01 2.90E-01 2.80E-01 BONE SUR 8 2.01E-01 2.25E-01 2.40E-01 2.46E-01 2.45E-01 2.40E-01 2.32E-01 2.24E-01 R MARROW 9 2.20E-01 2.46E-01 2.63E-01 2.69E-01 2.68E-01 2.62E-01 2.54E-01 2.45E-01 THYROID 10 5.78E+02 6.48E+02 6.92E+02 7.09E+02 7.06E+I02 6.92E+l02 6.71E+I02 6.46E+02 KTIDNEYS 11 1.62E-01 1.82E-01 1.94E-01 1.99E-01 1.98E-01 1.94E-01 1.88E-01 1.81E-01 LIVER 12 2.03E-01 2.28E-01 2.43E-01 2.49E-O1 2.48E-01 2.43E-01 2.35E-01 2.26E-01 SPLEEN 13 2.09E-01 2.34E-01 2.50E-01 2.56E-01 2.55E-01 2.49E-01 2.42E-01 2.33E-01 PANCREAS 14 2.34E-01 2.62E-01 2.80E-01 2.86E-01 2.85E-01 2.79E-01 2.70E-01 2.60E-01 MUSCLE 15 2.51E-01 2.81E-01 3.00E-01 3.08E-01 3.06E-01 3.00E-01 2.90E-01 2.80E-01 SKIN 16 1.78E-01 1.99E-01 2.13E-01 2.18E-01 2.17E-01 2.12E-01 2.06E-01 1.98E-01 THYMUS 18 5.40E-01 6.06E-01 6.47E-01 6.62E-01 6.59E-01 6.46E-01 6.26E-01 6.03E-01 BLWALL 19 1.31E-O1 1.47E-01 1.57E-01 1.61E.-01 1.60E-01 1.57E-01 1.52E-01 1.46E-01 ADRENALS 20 2.22E-01 2.48E-01 2.65E-01 2.71E-01 2.70E-01 2.64E-01 2.56E-01 2.47E-01 ESOPHAGU 21 5.40E-01 6.06E-01 6.47E-01 6.62E-01 6.59E-01 6.46E-01 6.26E-01 6.03E-01 OVARIES 22 1.29E-01 1.45E-01 1.55E-01 1.58E-01 1.58E-01 1.54E-01 1.49E-O1 1.44E-01 UTERUS 23 1.37E-01 1.54E-01 1.64E-01 1.68E-01 1.67E-01 1.64E-01 1.58E-01 1.53E-01 ORGANS WITH NO CALCULATED DOSE HAVE BEEN SUPPRESSED FROM TABLE
TEM-9002.ENGINEERING-DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 25 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6).
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:12 PAGE 5
DOWNWIND DISTANCES (in)
ORGAN NO. 8.00E+02 9.00E+02 1.00E+03 1.10E+03 1.20E+03 1.30E+03 1.40E+03 1.50E+03 THYROID 10 5.78E+02 6.48E+02 6.92E+02 7.09E+02 7.06E+02 6.92E+02 6.71E+02 6.46E+02 LUNGS 1 4.26E+f00 4.77E+00 5.10E+00 5.22E+00 5.20E+00 5.09E+00 4.93E+00 4.74E+00 S WALL 2 6.93E-01 -7.76E-01 8.28E-01 8.48E-01 8.43E-0I 8.25E-01 7.99E-01 7.69E-01 THYMUS 18 5.40E-01 6.06E-01 6.47E-01 6.62E-01 6.59E-01 6.46E-01 6.26E-01 6.03E-01 ESOPHAGU 21 5.40E-01 6.06E-01 6.47E-.01 6.62E-01 6.59E-01 6.46E-01 6.26E-01 6.03E-01 BREASTS 7 2.51E-0i 2.81E-.01 3.00E-01 3.08E-01 3.06E-01 3.00E-01 2.90E-01 2.80E-01 MUSCLE 15 2.51E-01 2.81E-O1 3.00E-01 3.08E-01 3.06E-01 3.00E.-01 2.90E-01 2.80E-01 PANCREAS 14 2.34E-01 2.62E-.01 2.80E-01 2.86E-01 2.85E-01 2.79E-01 2.70E-01 2.60E-01 ADRENALS 20 2.22E-01 2.48E-01 2.65E-O1 2.71E.-01 2.70E-01 2.64E-01 2.56E-01 2.47E-01 R MARROW 9 2.20E-01 2.46E-01 2.63E-01 2.69E-01 2.68E-01 2.62E-01 2.54E-01 2.45E-01 SPLEEN 13 2.09E-01 2.34E-01 2.50E-01 2.56E-01 2.55E-01 2.49E-01 2.42E-01 2.33E-01 LIVER 12 2.03E-01 2.28E-01 2.43E-01 2.49E-01 2.48E-01 2.43E-01 2.35E-01 2.26E-01 BONE STIR 8 2.01E-01 2.25E-01 2.40E-01 2.46E-01 2.45E-01 2.40E-01 2.32E-01 2.24E-01' SKIN 16 1.78E-01 1.99E-01 2.13E-01 2.18E-01 2.17E-01.2.12E-01 2.06E-01 1.98E-01 KIDNEYS 11 1.62E-01 1.82E-01 1.94E-01 1.99E-01 1.98E-01 1.94E-01 1.88E-01 1.81E-01 UILIWALL 4 1.47E-01 1.64E-01 1.75E-01 1.80E-01 1.79E-01 1.75E-01 1.69E-01 1.63E-01 SI WALL 3 1.45E-01 1.63E-01 1.74E-01 1.78E-01 1.77E-01 1.73E-01 1.68E-01 i.61E-01 UTERUS 23 1.37E-01 1.54E-01 1.64E-01 1.68E-01 1.67E-01 1.64E-01 1.58E-01 1,53E-01 LLI WALL 5 1.37E-01 1.53E-01 1.63E-01 1.67E-01 1.67E-01 1.63E-01 1.58E-01 1.52E-01 BLWALL 19 1.31E-01 1.47E-01 1.57E-01 1.61E-01 1.60E-01 1.57E-01 1.52E-01 1.46E-01 OVARIES 22 1.29E-01 1.45E-01 1.55E-01 1.58E-01 1.58E-01 l.54E-01 1.49E-01 1.44E-01 TESTES 6 1.24E-01 1.39E-01 1.49E-01 1.52E-01 1.51E-01 1.48E-01 1.44E-01 l.38E-01 ORGANS WITH NO CALCULATED DOSE HAVE BEEN SUPPRESSED FROM TABLE
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 26 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:12 PAGE 6
DOWNWIND DISTANCES (in)
ORGAN NO. 8.00E+02 9.00E+02 1.00E+I03 1.10E+03 1.20E+03 1.30E+03 1.40E+03 1.50E+03 LUNGS 1 5.11E-01 5.73E-01 6.12E-01 6.26E-01 6.23E-01 6.10E-01 5.91E-01 5.69Eo01 S WALL 2 4.16E-02 4.66E-02 4.97E-02 5.09E-02 5.06E-02 4.95E-02 4.79E-02 4.61E-02 SI WALL 3 8.71E-03 9.76E-03 1.04E-02 1.07E-02 1.06E-02 1.04E-02 1.01E-02 9.69E-03 ULI WALL 4 8.80E-03 9.86E-03 1.05E-02 1.08E-02 1.07E-02 1.05E-02 1.02E-02 9.79E-03 LLIWALL 5 8.20E-03 9.19E-03 9.81E.-03 1.00E-02 9.99E-03 9.78E-03 9.48E-03 9.12E-03 TESTES 6 3.11E-02 3.48E-02 3.72E-02 3.80E-02 3.79E-02 3.71E-02 3.59E-02 3.46E-02 BREASTS 7 3.76E-02 4.22E-02 4.51E-02 4.61E-02 4.59E-02 4.50E-02 4.36E-02 4.20E-02 BONE SUR. 8 6.02E-03 6.75E-03 7.20E-03 7.38E-03 7.34E-03 7.19E-03 6.96E-03 6.71E-03 RMAIRROW 9 2.64E-02 2.95E-02 3.15E-02 3.23E-02 3.21E-02 3.15E-02 3.05E-02 2.94E-02 TH-YROID 10 1.73E+01 1.94E+0-1 2.08E+01 2.13E+0-1 2.12E+01 2.08E+01 2.01E+01 1.94E+01 KIDNEYS 11 9.74E-03 1.09E-02 1.16E-02 1.19E-02 1.19E-02 1.16E-02 1.13E-02 1.08E-02 LIVER 12 1.22E-02 1.37E-02 1.46E-02 1.49E-02 1.49E-02 1.46E-02 1.41E-02 1.36E-02 SPLEEN 13 1.26E-02 1.41E-02 l.50E-02 1.54E.4)2 1.53E-02 1.50E-02 1.45E-02 1.40E-02 PANCREAS 14 1.40E-02 1.57E-02 1.68E-02 1.72E-02 1.71E-02 1.67E-02 1.62E-02 1.56E-02 MUSCLE 15 1.5 1E-02 1.69E-02 1,80E-02 1.85E-02 1.84E-02 1,80E-02 1,74E-02 1.68E-02 SKIN 16 1.78E-03 1.99E-03 2.13E-03 2.18E-03 2.17E-03 2.12E-03 2.06E-03 1.98E-03 TrHYMUS 18 3.24E-02 3.63E-02 3.88E-02 3.97E-02 3.96E-02 3.87E-02 3.75E-02 3.62E-02 BL WALL 19 7.89E-03 8.83E-03 9.43E-03 9.65E-03 9.6 1E-03 9.40E-03 9.11E-03 8.77E-03 ADRENALS 20 1.33E-02 1.49E-02 1.59E-02 1.63E-02 1.62E-02 1.59E-02 1.54E-02 1.48E-02 ESOPHAGU 21 3.24E-02 3.63E-02 3.88E-02 3.97E-02 3.96E-02 3.87E-02 3.75E-02 3.62E-02 OVARIES 22 3.23E-02 3.62E-02 3.87E-02 3.96E-02 3.94E-02 3.85E-02 3.73E-02 3.60E-02 UTERUS 23 8.23E-03 9.22E-03 9.84E3-03 1.01E-02 1.00E-02 9.81E-03 9.51E-03 9.15E-03 CEDE 24 1.80E+01 2.02E+0-1 2.16E+01 2.21E+01 2.21E+01 2.16E+0-1 2.09E+01 2.02E+-01 ORGANS WITH NO CALCULATED DOSE HAVE BEEN SUPPRESSED FROM TABLE
- GAMMA4~ DOSE CALCULATION WITH EXPOSURE TIMVE = 7. 1994E+03 (s)
CALCULATIONS MADE USING THE FINITE MODEL EXTERNAL EDE DOWNWIND DISTANCE = 8.000E+02 (in)
DOSE = 4.48E-01 (rem)
DOWNWIND DISTANCE = 9.000E+02 (in)
DOSE = 4.26E-01 (remn)
DOWNWIND DISTANCE = 1.000E+03 (in)
DOWNWIND DISTANCE = 1.100E+03 (in)
DOSE = 3.92E-01 (rem)
DOWNWIND DISTANCE = !.200E+03 (in)
DOSE = 3.76E-01 (rem)
DOWNWIND DISTANCE = 1.300E+-03 (mn)
DOSE = 3.60E-01 (rein)
DOWNWIND DISTANCE = 1.400E+03 (in)
DOSE = 3.45E-O1 (rem)
DOWNWIND DISTANCE = 1.500E+03 (mn)
DS=33EO r
DOSE = 3.31E-01 (rem)
TEM-9002 09129109 Rev. 0 ENGINEERING DESIGN FILE EDF-31 24-0003 Rev. 2 Page 27 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:12 PAGE 7
- Iodine MHA Analysis EXECUTION time = 2.90E-01 SECONDS
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09/29/09 Rev. 2 Rev. 0 Page 28 of 59 RSAC-6 INPUT 20160121 07:51 0
1 2
3 4
5 6
7.
123456789012345678901234567890123456789012345678901234567890 12345678901t23456789
- Krypton MBA Analysis
- Line replaced by WinRp to use temporary external file srcl.txt
- 2002,C:\\Users\\dthorne\\Documents\\Rsac\\Input Files\\Krypton_2016.txt 2002, srcl.txt 2999
- F Stability and 2 m/s 5000,0 500 1,2.,22.86,400., 1240.,0.,0 5101, 10., 100.,200.,300.,430.,500.,600.,700.
5201,1.389E-4,0.
5400,2,0.,0.,0 5410,3,6,0 5999
- Dose Data.
7000,0,-2, 1,0,1 700 1,3.47E-04,0.,0,0, 1.
7999
- Gloud Gamma 9000,0,0.
10000 0
1 2
3 4
5 6
7 123456789012345678901234567890123456789012345678901234567890 1234567890123456789
TEM-9002 ENGINEERING DESIGN FILE EDF-31 24-0003 09129109 Rev. 2 Rev. 0 Page 29 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC..6)
(RSAC..6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 07:5 1PAGE 1
- Krypton MHA Analysis
- DIPECT RADIONUCLIDE INPUT ANY PREVIOUS INVENTORY HAS BEEN ZEROED NUCLIDE HALF LIFE CURIES 360831 Kr83m 1.830E+00 h 9.650E+02 360850 Kr85 1.076E+01 yr 2.980E+01 360851 Kr 85m 4.480E+01 h 2.360E+03 360870 Kr 87 7.630E+01 m 2.120E+02 360880 Kr 88 2.840E+00 h 3.180E+03
- METEOROLOGICAL DATA MEAN WIND SPEED = 2.000E+00 (m/s) STACK HEIGHT =2.286E+01 (in)
MIXING LAYER HEIGHT = 4.000E+02 (in)
AIR DENSITY = 1.240E+03 (g/cu m)
WET DEPOSITION SCAVENGING COEFFICIENT --0.000E+00 (1/S)
NO CORRECTION IS BEING MADE FOR PLUME DEPLETION BY FALLOUT DEFAULT DRY DEPOSITION VELOCITIES (m/s)
SOLIDS = 0.000E+00 HALOGENS = 0.000E+00 NOBLE GASES = 0.000E+00 CESIUM = 0.000E+00 RUTHENIUM = 0.000E+00 THERE IS 1 SET OF LEAKAGE CONSTANTS (K1,K2) 1.389E-04 0.000E+00 PASQUILL CLASS F METEOROLOGY, P-G SIGMA VALUES WARNING - DIFFUSION FOR DISTANCES OF LESS THAN 100 METERS IS EXTRAPOLATED ENHANCED DEPOSITION PARAMETERS PARTICLE DIAMETER = 0.000E+00 (mn) PARTICLE DENSITY = 0.000E+00 (g/cm3)
DOWNWIND DISTANCE STACK SIGY SIGZ CHI!Q HEIGHT (in) (mn)
(in)
(s/cu mn) 1.000E+01 2.286E+01 5.776E-01 3.454E-01 0.000E+00 DOWNWIND DISTANCE STACK SIGY SIGZ CHIIQ HEIGHT (mn) (mn)
(mn)
(s/cu m) 1.000E+f02 2.286E+01 4.621E+00 2.247E+I00 5.171E-25
TEM-9002 09129109 Rev. 0 ENGINEERING DESIGN FILE EDF-31 24-0003 Rev. 2 Page 30 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 07:5 1PAGE 2
- Krypton MHA Analysis DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 2.000E+02 2.286E+0O1 8.642E+00 DOWNWIND DISTANCE STACK HEIGHT (in)
(mn)
(in) 3.000E+02 2.286E+01 1.246E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 4.300E-+02 2.286E+01 1.725E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 5.000E+I02 2.286E+01 1.977E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 6.000E+02 2.286E+0-1 2.331E+01.
DOWNWIND DISTANCE STACK HEIGHT (in)
(mn)
(in) 7.000E+02 2.286E+01 2.679E+01 SIGY SIGZ CHI/Q (s/cu mn) 3.988E+-00 3.376E-10 SIGY SIGZ CIJI/Q (s/cu in) 5.506E+00 4. 185E-07 SIGY SIGZ CHI/IQ (s/cu in) 7.293E+00 9.302E-06 SIGY SIGZ CHI/Q (s/cu in) 8.I95E+00 2.008E-05 SIGY SIGZ CHI/Q (s/cu in) 9.430E+00 3.834E-05 SIGY SIGZ CHIIQ (s/cu mn) 1.061E+01 5.500E-05
- INHALATION DOSE EQUIVALENT CALCULATION USING DOSE CONVERSION FACTORS FROM FEDERAL GUIDANCE REPORT 11 RESPIRABLE FRACTION = 1.000E+00 BREATHING RATE = 3.470E-04 (cu nm/s)
RELEASE TIME FOR EXPONENTIAL DECAY FUNCTION = 7.I199E+03 (s)
INTERNAL EXPOSURE TIME PERIOD =5.000E+0I (yr)
PARTICLE SIZE = 1.0 MICRON AMAD LUNG DEPOSITION FRACTIONS: N-P = 0.300 T-B =0.080 P = 0.250 DEFAULT ELEMENT LUNG CLEARANCE CLASSES SELECTED TO GIVE MAXIMUM DOSE
TEM-9002
.ENGINEERING DESIGN FILE EDF-31 24-0003 09/29/09 Rev. 2 Rev. 0 Page 31 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 07:5 1PAGE 3
- Krypton MHA Analysis DOWNWIND DISTANCE = 1.000E+01 (in)
PLUME TRAVEL TIME =5.000E+00 (s)
CEHI/Q = 0.000E+00 (s/cu m)
DOWNWIND DISTANCE = 1.000E+02 (mn) PLUME TRAVEL TIME = 5.000E+01 (s)
CHI/Q = 5. 171E-25 (s/cu m)
DOWNWIND DISTANCE -- 2.000E+02 (mn) PLUME TRAVEL TIME = 1.000E+I02 (s)
CHI/IQ = 3.376E3-10 (s/cu mn)
DOWNWIND DISTANCE = 3.000E+02 (in)
PLUME TRAVEL TIMVE = 1.500E+02 (s)
CHTIQ = 4. 185E-07 (s/cu in)
DOWNWIND DISTANCE = 4.300OE+02 (in)
PLUME TRAVEL TIME = 2. 150E+02 (s)
CHI/Q = 9.302E-06 (s/cu in)
DOWNWIND DISTANCE = 5.000E+02 (in)
PLUME TRAVEL TIME =2,500E+-02 (s)
CHI/IQ = 2.008E-05 (s/cu in)
DOWNWIND DISTANCE = 6.000E+02 (in)
PLUME TRAVEL TIME = 3.000E+I02 (s)
CHIIQ = 3.834E-05 (s/cu in)
DOWNWIND DISTANCE = 7.000E+02 (in)
PLUME TRAVEL TIME = 3.500E+02 (s)
CIII/Q = 5.500E-05 (s/cu in)
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 32 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 07:51 PAGE 4
DOWNWIND DISTANCES (in)
ORGAN NO. 1.00E+01 1.00E+02 2.00E+02 3.00E+02 4.30E+102 5.00E+02 6.00E+0i2 7.00E+02 LUNGS 1 0.00E+00 2.03E-22 1.34E-07 1.67E-04 3.74E-03 8.10E-03 1.55E-02 2.24E-02 S WALL 2 0.00E+00 8.56E-23 5.62E-08 7.02E-05 1.57E-03 3.41E-03 6.54E-03 9.42E-03 SI WALL 3 0.00E+0-0 2.23E-24 1.46E-09 1.83E-06 4.L0E-05 8.88E-05 1.71E-04 2.46E-04 ULI WALL 4 0.00E+0-0 2.70E-24 1.78E-09 2.22E-06 4.98E-05 1.08E-04 2.08E-04 3.00E-04 LLI WALL 5 0.00E+00 3.40E-24 2.24E-09 2.80E-06 6.28E-05 1.36E-04 2.62E-04 3.79E-04 TESTES 6 0.00E+00 1.73E-24 1.14E-09 1.42E-06 3.18E-05 6.89E-05 1.32E-04 1.91E-04 BREASTS 7 0.00E+00 2.04E-24 1.34E-09 1.67E-06 3.74E-05 8.10E-05 1.56E-04 2.24E-04 BONE STUR 8 0.00E+00 2.07E-24 1.36E-09 1.70E-06 3.81E-05 8.25E-05 1.58E-04 2.28E-04 RMARROW 9 0.00E+i00 2.09E-24 l.37E-09 1.71E-06 3.83E-05 8.31E-05 1.59E-04 2.30E-04 THYROID 10 0.00E+I00 1.92E-24 1.26E-09 1.57E-06 3.52E-05 7.63E-05 1.47E-04 2.11E-04 KIDNEYS 11 0.00E+0-0 2.04E-24 1.34E-09 1.68E-06 3.75E-05 8.14E-05 1.56E-04 2.25E-04 LIVER 12 0.00E+O0 2.28E-24 1.50E-09 1.87E-06 4.19E-05 9.09E-05 1.75E-04 2.52E-04 SPLEEN 13 0.00E+00 2.48E-24 1.63E-09 2.03E-06 4.56E-05 9.87E-05 1.90E-04 2.73E-04 PANCREAS 14 0.00E+00 2.85E-24 1.87E-09 2.34E-06 5.23E-05 1.13E-04 2.18E-04 3.14E-04 MUSCLE 15 0.00E+00 2.04E-24 1.34E-09 1.67E-06 3.74E-05 8.10E-05 1.56E-04 2.24E-04 SKIN 16 0.00E+00 1.82E-24 1.19E-09 1.49E-06 3.34E-05 7.23E-05 1.39E-04 2.00E-04 BRAIN 17 0.00E+00 1.70E-24 1.12E-09 1.39E-06 3.12E-05 6.76E-05 1.30E-04 1.87E-04 THYMUS 18 0.00E+00 2.57E-24 1.69E-09 2.11E-06 4.72E-05 1.02E-04 1.96E-04 2.83E-04 EL WAIL 19 0.00E+0-0 1.82E-24 1.20E-09 1.50E-06 3.3 5E-05 7.27E-05 1.40E-04 2.01E-04 ADRENALS 20 0.00E+00 2.23E-24 1.47E-09 1.83E-06 4.10E-05 8.88E-05 1.71E-04 2.46E-04 ESOPHAGU 21 0.00E+i00 2.57E-24 1.69E-09 2.11E-06 4.72E-05 1.02E-04 1.96E-04 2.83E-04 OVARIES 22 0.00E+0I0 2.07E-24 1.36E-09 1.70E-06 3.80E-05 8.25E-05 1.58E-04 2.29E-04 UTERUS 23 0.00E+i00 1.92E-24 1.26E-09 1.58E-06 3.53E-05 7.66E-05 1.47E-04 2.12E-04
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 33 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 07:51 PAGE 5
- Krypton MHA Analysis INHALATION COMMIT1TED DOSE EQUIVALENCES ORDERED BYDOSE (remn)
DOWNWIND DISTANCES (in)
ORGAN NO. 1.00E+01 1.00E+02 2.00E+02 3.00E+02 4.30E+02 5.00E+02 6.00E+02 7.00E+02 LUNGS 1 0.00E+00 2.03E-22 1.34E-07 1.67E-04 3.74E-03 8.10E-03 1.55E-02 2.24E-02 S WALL 2 0.00E+00 8.56E-23 5.62E-08 7.02E-05 1.57E-03 3.41E-03 6.54E-03 9.42E-03 SI WALL 3 0.00E+i00 2.23E-24 1.46E-09 1.83E-06 4.10E-05 8.88E-05 1.71E-04 2.46E-04 ULI WALL 4 0.00E+00 2.70E-24 1.78E-09 2.22E-06 4.98E-05 1.08E-04 2.08E-04 3.00E-04 LUI WALL 5 0.00E+00 3.40E-24 2.24E-09 2.80E-06 6.28E-05 1.36E-04 2.62E-04 3.79E-04 TESTES 6 0.00E+00 1.73E-24 1.14E-09 1.42E-06 3.18E-05 6.89E-05 1.32E-04 1.91E-04 BREASTS 7 0.00E+I00 2.04E-24 1.34E-09 1.67E-06 3.74E-05 8.10E-05 1.56E-04 2.24E-04 BONE SUR 8 0.00E+00 2.07E-24 1.36E-09 1.70E-06 3.81E-05 8.25E-05 1.58E-04 2.28E-04 RMARROW 9 0.00E+00 2.09E-24 1.37E-09 1.71E-06 3.83E-05 8.31lE-05 1.59E-04 2.30E-04 THYROID 10 0.00E+00 1.92E-24 1.26E-09 1.57E-06 3.52E-05 7.63E-05 1.47E-04 2.11E-04 KIDNEYS 11 0.00E+00 2.04E-24 1.34E--09 1.68E-06 3.75E-05 8.14E-05 1.56E-04 2.25E-04 LIVER 12 0.00E+00 2.28E-24 1.50E-09 1.87E-06 4.19E-05 9.09E-05 1.75E-04 2.52E-04 SPLEEN 13 0.00E+00O 2.48E-24 1.63E-09 2.03E-06 4.56E-05 9.87E-05 1.90E-04 2.73E-04 PANCREAS 14 0.00E+I00 2.85E-24 1.87E-09 2.34E-06 5.23E-05 1.13E-04 2.18E-04 3.14E-04 MUSCLE 15 0.00E+00 2.04E-24 1.34E-09 1.67E-06 3.74E-05 8.10E-05 1.56E-04 2.24E-04 SKIN 16 0.00E+00 1.82E-24 1.19E-09 1.49E-06 3.34E-05 7.23E-05 1.39E-04 2.00E-04 BRAIN 17 0.00E+00 1.70E-24 1.12E-09 1.39E-06 3.12E-05 6.76E-05 1.30E-04 1.87E-04 THTYMvUS 18 0.00E+I00 2.57E-24 1.69E-09 2.11E-06 4.72E-05 1.02E-04 1.96E-04 2.83E-04 BL WALL 19 0.00E+00 1.82E-24 1.20E-09 1.50E-06 3.35E-05 7.27E-05 1.40E-04 2.01E-04 ADRENALS 20 0.00E+00 2.23E-24 1.47E-09 1.83E-06 4.10E-05 8.88E-05 1.71E-04 2.46E-04 ESOPHAGU 21 0.00E+00 2.57E-24 1.69E-09 2.11E-06 4.72E-05 1.02E-04 1.96E-04 2.83E-04 OVARIES 22 0.00E+0-0 2.07E-24 1.36E-09 1.70E-06 3.80E-05 8.25E-05 1.58E-04 2.29E-04 UTERUS 23 0.00E+00 1.92E-24 1.26E-09 1.58E-06 3.53E-05 7.66E-05 1.47E-04 2.12E-04
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 34 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-.6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 07:5 1PAGE 6
DOWNWIND DISTANCES (in)
ORGAN NO. 1.00E+01 1.00E+02 2.00E+02 3.00E+02 4.30E+02 5.00E+02 6.00E+02 7.00E+02 LUNGS 1 0.00E+00 2.44E-23 1.60E-08 2.00E-05 4.48E-04 9.72E-04 1.86E-03 2.69E-03 S WALL 2 0.00E+00 5.13E-24 3.37E-09 4.21E-06 9.43E-05 2.04E-04 3.92E-04 5.65E-04 SI WALL 3 0.00E+00 1.34E-25 8.78E-11 1.10E-07 2.46E-06 5.33E-06 1.02E-05 1.48E-05 ULI WALL 4 0.00E+00 1.62E-25 1.07E-10 1.33E-07 2.99E-06 6.48E-06 1.25E-05 1.80E-05 LUIWALL 5 0.00E+00.2.04E-25 1.34E-10 1.68E-07 3.77E-06 8.18E-06 1.57E-05 2.28E-05 TESTES 6 0.00E+00 4.33E-25 2.84E-10 3.55E-07 7.95E-06 1.72E-05 3.31E-05 4.76E-05 BREASTS 7 0.00E+00 3.05E-25 2.01E-10 2.50E-07 5.61E-06 1.22E-05 2.33E-05 3.36E-05 BONE SUR 8 0.00E+O0 6.22E-26 4.09E-11 5.I0E-08 1.14E-06 2.47E-06 4.75E-06 6.85E-06 R MARROW 9 0.00E+00 2.50E-25 1.65E-10 2.05E-07 4.60E-06 9.97E-06 1.91E-05 2.76E-05 TIHYROID 10 0.00E+00 5.75E-26 3.78E-11 4.72E-08 1.06E-06 2.29E-06 4.40E-06 6.34E-06 KIDNEYS 11 0.00E+0-0 1.23E-25 8.06E-11 1.01E-07 2.25E-06 4.88E-06 9.37E-06 1.35E-05 LIVER 12 0.00E+f00 1.3'7E-25 9.00E-11 1.12E-07 2.52E-06 5.45E-06 1.05E-05 1.51E-05 SPLEEN 13 0.00E+00 1.49E-25 9.78E-l1 1.22E-07 2.73E-06 5.92E-06 1.14E-05 1.64E-05 PANCREAS 14 0.00E+00 1.71E-25 1.12E-10 1.40E-07 3.14E-06 6.80E-06 1.31E-05 1.88E-05 MUSCLE 15 0.00E+00 1.22E-25 8.03E-11 1.00E-07 2.24E-06 4.86E-06 9.34E-06 1.35E-05 SKIN 16 0.00E+00 1.82E-26 1.19E-11 1.49E-08 3.34E-07 7.23E-07 1.39E-06 2.00E-06 BRAIN 17 0.00E+00 1.02E-25 6.70E-11 8.35E-08 1.87E-.06 4.05E-06 7.78E-06 1.12E-05 THYMvUS 18 0.00E+00 1.54E-25 1.01E-10 1.26E-07 2.83E-06 6.14E-06 1.18E-05 l.70E-05 BLWALL 19 0.00E+00 1.09E-25 7.20E-11 8.98E-08 2.01E-06 4.36E-06 8.37E-06 1.21E-05 ADRENALS 20 0.00E+00 1.34E-25 8.80E-11 1.10E-07 2.46E-06 5.33E-06 1.02E-05 1.48E-05 ESOPHAGU 21 0.00E+00 1.54E-25 1.01E-10 1.26E-07 2.83E-06 6.14E-06 1.18E-05 1.70E-05 OVARIES 22 0.00E+i00 5.17E-25 3.40E-10 4.24E-07 9.51E-06 2.06E-05 3.96E-05 5.71E-05 UTERUS 23 0.00E+00 1.15E-25 7.58E-11 9.46E-08 2.12E-06 4.60E-06 8.82E-06 1.27E-05 CEDE 24 0.00E+00 3.15E-23 2.07E-08 2.58E-05 5.79E-04 1.25E-03 2.41E-03 3.47E-03
- GAMA4 DOSE CALCULATION WITH EXPOSURE TIME =7.1994E+03 (s)
CALCULATIONS MADE USING THE FINITE MODEL EXTERNAL EDE DOWNWIND DISTANCE = 1.000E+01 (in)
DOSE = 1.88E-02 (remn)
DOWNWIND DISTANCE = 1.000E+02 (in)
DOSE = 3.60E-02 (rem)
DOWNWIND DISTANCE = 2.000E+02 (mn)
DOSE = 3.48E-02 (rem)
DOWNWIND DISTANCE = 3.000E+f02 (mn)
DOSE = 3.31lE-02 (rem)
DOWNWIND DISTANCE = 4.300E+02 (in)
DOSE = 3.15E-02 (rem)
DOWNWIND DISTANCE = 5.000E+02 (in)
DOSE = 3.09E-02 (rem)
DOWNWIND DISTANCE =6.000E+02 (in)
DOE=29E0(rm DOSE = 2.99E-02 (rem)
TEM-9002 09129/09 Rev. 0 ENGINEERING DESIGN FILE EDF-3124-0003 Rev. 2 Page 35 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 07:5 1PAGE 7
- Krypton MHA Analysis DOWNWIND DISTANCE =7.000E+02 (in)
EXECUTION time = 3.20E-01 SECONDS DOSE = 2.86E-02 (rem)
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129/09 Rev. 2 Rev. 0 Page 36 of 59 RSAC-6 INPUT 20160121 08:05 0
1 2
3 4
5 6
7 123456789012345678901234567890123456789012345678901234567890 1234567890123456789
- Line replaced by WinRp to use temporary external file src 1.txt
- 2002,C:\\Users\\dthorne\\Documnents\\Rsac*Input Files\\Krypton_2016.txt 2002,srcl.txt 2999
- F Stability and 2 mn/s 5000,0 500 1,2.,22.86,400.,1240.,0.,0 51l01,800.,900.,1000.,1 100.,1200.,1300.,1400.,1500.
5201,1.389E-4,0.
5400,2,0.,0.,0 5410,3,6,0 5999
- Dose Data 7000,0,-2, 1,0,1 7001,3.47E-04,0.,0,0,1.
7999
- Cloud Gamma 9000,0,0.
10000 0
1 2
3 4
5 6
7 123456789012345678901234567890 1234567890123456789012345678901234567890123456789
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 R ev. 2 Rev. 0 Page 37 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:05 PAGE 1
- Krypton MHA Analysis
- D~IRECT RADIONUCLIIDE IN~PUT ANY PREVIOUS INVENTORY HAS BEEN ZEROED NUCLIDE HALF LIFE CURIES 360831 Kr83m 1.830E+00 hi 9.650E+02 360850 Kr85 1.076E+01 yr 2.980E+I01 360851 Kr 85m 4.480E+I01 h 2.360E+I03 360870 Kr87 7.630E+01 m 2.120E+02 360880 Kr 88 2.840E+I00 h 3.180E+03
- METEOROLOGICAL DATA MEAN WIND SPEED = 2.000E+00 (m/s) STACK HEIGHT = 2.286E+01 (in)
MIXING LAYER HEIGHT =4.000E+02 (mn)
AIR DENSITY = l.240E+03 (g/cu mn)
WET DEPOSITION SCAVENGING COEFFICIENT =0.000E+00 (I/S)
NO CORRECTION IS BEING MADE FOR PLUME DEPLETION BY FALLOUT DEFAULT DRY DEPOSITION VELOCITIES (m/s)
SOLIDS -- 0.000E+00 HALOGENS = 0.000E+00 NOBLE GASES = 0.000E+00 CESIUM = 0.000E+00 RUTHENIUM = 0.000E+00 THERE ISi1 SET OF LEAKAGE CONSTANTS (K1,K2) 1.389E-04 0.000E+00 PASQUILL CLASS F METEOROLOGY, P-G SIGMA VALUES ENHANCED DEPOSITION PARAMETERS PARTICLE DIAMETER = 0.000E+00 (in) PARTICLE DENSITY = 0.000E+00 (g/cm3)
DOWNWIND DISTANCE STACK.SIGY SIGZ CHI/Q HEIGHT (in)
(in)
(in)
(s/cu m) 8.000E+02 2.286E+01 3.022E+01 1.175E+01 6.754E-05 DOWNWIND DISTANCE STACK SIGY SIGZ CHIIQ HEIGHT (mn) (mn)
(mn)
(s/cu mn) 9.000E+02 2.286E+01 3.361E+0 1 1.285E+0 1 7.574E-05
TEM-9002 09129109 Rev. 0 ENGINEERING DESIGN FILE ED F-3 124-0003 Rev. 2 Page 38 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:05 PAGE 2
- Kryton MHA Analysis DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(mn) 1.000E+03 2.286E+01 3.697E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 1.100E+I03 2.286E+01 4.029E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(mn)
(mn) 1.200E+03 2.286E+I01 4.359E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 1.300E+03 2.286E+01 4.685E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 1.400E+03 2.286E+01 5.010E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(mn) 1.500E+03 2.286E+01 5.332E+01 SIGY SIGZ CHI/Q (s/cu m) l.399E+01 8.094E-05 SIGY SIGZ CHI/Q (s/cu m) 1.507E+0 1 8.294E-05 SIGY SIGZ CHI/Q (s/cu mn) 1.607E+01 8.263E-05 SIGY SIGZ CHI/IQ (s/cu mn) 1.70 1E+01 8.095E-05 SIGY SIGZ CHI/Q (s/cu mn) 1.789E+01 7.85 1E-05 SIGY SIGZ CHI/Q (s/cu m) 1.872E+01 7.566E-05
- INHALATION DOSE EQUIVALENT CALCULATION USING DOSE CONVERSION FACTORS FROM FEDERAL GUIDANCE REPORT 11 RESPIRABLE FRACTION = 1.000E+-00 BREATHING RATE = 3.470E-04 (cu m/s)
RELEASE TIME FOR EXPONENTIAL DECAY FUNCTION = 7.1 99E+03 (s)
INTERNAL EXPOSURE TIME PERIOD =5.000E+01 (yr)
PARTICLE SIZE = 1.0 MICRON AMAD LUNG DEPOSITION FRACTIONS: N-P = 0.300 T-B = 0.080 P =0.250 DEFAULT ELEMENT LUNG CLEARANCE CLASSES SELECTED TO GIVE MAXIMUM DOSE
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 39 of 59 RADIOLOGICAL SAF7ETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIMVE 08:05 PAGE 3
- Krypton MHA Analysis DOWNWIND DISTANCE = 8.000E+02 (in)
PLUME TRAVEL TIME = 4.000E+02 (s)
CHI/Q = 6.754E-05 (s/cu m)
DOWNWIND DISTANCE = 9.000E+02 (in)
PLUME TRAVEL TIME = 4.500E+02 (s)
CHI/Q = 7.574E-05 (s/cu m)
DOWNWIND DISTANCE = 1.000E+03 (mn) PLUME TRAVEL TIME = 5.000E+02 (s)
CHI/Q =8.094E-05 (s/cu mn)
DOWNWIND DISTANCE = 1.100E+03 (mn) PLUME TRAVEL TIME = 5.500E+02 (s)
CHI/Q = 8.2 94E-05 (s/cu mn)
DOWNWIND DISTANCE = 1.200E+f03 (in)
PLUME TRAVEL TIME = 6.000E+02 (s)
CHI/Q =8.263E-05 (s/cu m)
DOWNWIND DISTANCE = 1.300E+03 (in)
PLUME TRAVEL TlIME -- 6.500E+I02 (s)
CI{IQ = 8.095E-05 (s/cu mn)
DOWNWIND DISTANCE = 1.400E+03 (mn) PLUME TRAVEL TIME = 7.000E+02 (s)
CHIL/Q = 7.851lE-05 (s/cu in)
DOWNWIND DISTANCE = 1.500E+03 (in)
PLUME TRAVEL TIME = 7.500E-H)2 (s)
CHI/Q = 7.566E-05 (s/cu mn)
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 40 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIMvE 08:05 PAGE 4
- Krypton MHA Analysis INHALATION COMMLTFED DOSE EQUIVALENTS ORDERED BY ORGAN (remn)
DOWNWIND DISTANCES (in)
ORGAN NO. 8.00E+02 9.00E+02 1.00E+03 1.10E+I03 1.20E+03 1.30E+03 1.40E+03 1.50E+-03 LUNGS 1 2.76E-02 3.1lE-02 3.34E-02 3.44E-02 3.44E-02 3.38E-02 3.28E3-02 3.17E-02 S WALL 2
1.16E-02 1.3 1E-02 1.40E-02 1.44E-02 1.44E-02 1.42E-02 1.38E-02 1.33E-02 SI WALL 3 3.04E-04 3.43E-04 3.68E3-04 3.79E-04 3.79E-04 3.73E-04 3.63E-04 3.51E-04 ULI WALL 4 3.71E-04 4.18E-04 4.50E-04 4.63E-04 4.64]3-04 4.57E-04 4.45E-04 4.31E-04 LUI WALL 5 4.69E-04 5.30E-04 5.70E-04 5.88E-04 5.89E-04 5.81E-04 5.67E-04 5.50E-04 TESTES 6 2.35E3-04 2.65E-04 2.84E3-04 2.92E-04 2.92E-04 2.87E-04 2.80E-04 2.70E-04 BREASTS 7 2.77E-04 3.12E-04 3.35E-04 3.44E-04 3.44E-04 3.38E-04 3.29E-04 3.18E-04 BONE SUP. 8 2.82E-04 3.17E-04 3.41E3-04 3.50E3-04 3.50E-04 3.44E-04 3.35E-04 3.24E-04 RMAIRROW 9 2.84E-04 3.20E-04 3.43E-04 3.53E-04 3.53E3-04 3.47E-04 3.38E-04 3.26E-04 THYROID 10 2.61E-04 2.94E-04 3.15E-04 3.24E-04 3.24E-04 3.18E3-04 3.10E-04 2.99E-04 KIDNEYS 11 2.78E-04 3.13E-04 3.36E-04 3.46E-04 3.46E-04 3.40E-04 3.31E-04 3.20E-04 LIVER 12 3.10E-04 3.50E3-04 3.75E-04 3.86E-04 3.86E-04 3.80E-04 3.69E-04 3.57E-04 SPLEEN 13 3.37E-04 3.80E-04 4.08E-04 4.19E-04 4.19E-04 4.12E-04 4.01E-04 3.88E-04 PANCREAS 14 3.87E3-04 4.361E-04 4.68E3-04 4.82E3-04 4.82E3-04 4.74E-04 4.61E-04 4.46E-04 MUSCLE 15 2.77E-04 3.12E-04 3.35E-04 3.44E-04 3.44E-04 3.38E-04 3.29E-04 3.18E-04 SKIN 16 2.47E-04 2.78E-04 2.99E-04 3.07E-04 3.07E-04 3.02E-04 2.94E3-04 2.84E-04 BRAIN 17 2.3 1E-04 2.60E-04 2.79E-04 2.87E-04 2.87E-04 2.82E-04 2.74E-04 2.65E-04 THIYMVUS 18 3.49E-04 3.94E-04 4.23E-04 4.35E-04 4.35E-04 4.27E-04 4.16E-04 4.02E-04 BL WALL 19 2.48E-04 2.80E-04 3.00E-04 3.09E-04 3.09E-04 3.04E-04 2.95E-04 2.86E-04 ADRENALS 20 3.03E3-04 3.42E-04 3.67E-04 3.77E-04 3.77E-04 3.71E-04 3.61E-04 3.49E-04 ESOPHAGU 21 3.49E3-04 3.94E-04 4.23E-04 4.35E-04 4.35E-04 4.27E-04 4.16E-04 4.02E-04 OVARIES 22 2.82E-04 3.18E-04 3.41E-04 3.52E-04 3.52E-04 3.46E-04 3.37E-04 3.26E-04 UTERUS 23 2.62E-04 2.95E-04 3.16E-04 3.26E-04 3.26E-04 3.20E-04 3.12E-04 3.01E-04
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09/29109 Rev. 2 Rev. 0 Page 41 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11102) SERIAL 1 DATE 20160120 TIME 08:05 PAGE 5
DOWNWIN4D DISTANCES (in)
ORGAN NO. 8.00E+02 9.00E+02 1.00E+03 1.10E+03 1.20E+I03 1.30E+03 1.40E+I03 1.50E+03 LUNGS 1 2.76E-02 3.11E-02 3.34E-02 3.44E-02 3.44E-02 3.38E-02 3.28E-02 3.17E-02 S WALL 2 1.16E-02 1.31E-02 1.40E-02 1.44E-02 1.44E-02 1.42E-02 l.38E-02 1.33E-02 LLI WALL 5 4.69E-04 5.30E-04 5.70E-04 5.88E-04 5.89E-04 5.81E-04 5.67E-04 5.50E-04 PANCREAS 14 3.87E-04 4.36E-04 4.68E-04 4.82E-04 4.82E-04 4.74E-04 4.61lE-04 4.46E-04 ULI WALL 4 3.71E-04 4.18E-04 4.50E-04 4.63E-04 4.64E-04 4.57E-04 4.45E-04 4.3 1E-04 THYMVUS 18 3.49E-04 3.94E-04 4.23E-04 4.35E-04 4.35E-04 4.27E-04 4.16E-04 4.02E-04 ESOPI{AGU 21 3.49E-04 3.94E-04 4.23E-04 4.35E-04 4.35E-04 4.27E-04 4.16E-04 4.02E-04 SPLEEN 13 3.37E-04 3.80E-04 4.08E-04 4.19E-04 4.19E-04 4.12E-04 4.01E-04 3.88E-04 LIVER 12 3.10E-04 3.50E.-04 3.75E-04 3.86E-04 3.86E-04 3.80E-04 3.69E-04 3.57E-04 SI WALL 3 3.04E-04 3.43E-04 3.68E-04 3.79E-04 3.79E-04 3.73E-04 3.63E-04 3.5 1E-04 ADRENALS 20 3.03E-04 3.42E-04 3.67E-04 3.77E-04 3.77E-04 3.71E-04 3.61E-04 3.49E-04 RMARIROW 9 2.84E-04 3.20E-04 3.43E-04 3.53E-04 3.53E-04 3.47E-04 3.38E-04 3.26E-04 OVARIES 22 2.82E-04 3.18E-04 3.41E-04 3.52E-04 3.52E-04 3.46E-04 3.37E-04 3.26E-04 BONE SUR. 8 2.82E-04 3.17E-04 3.41E-04 3.50E-04 3.50E-04 3.44E-04 3.35E-04 3.24E-04 KIDNEYS 11 2.78E-04 3.13E-04 3.36E-04 3.46E-04 3.46E-04 3.40E-04 3.31E-04 3.20E-04 BREASTS 7 2.77E-04 3.12E-04 3.35E-04 3.44E-04 3.44E-04 3.38E-04 3.29E-04 3.18E-04 MUSCLE 15 2.77E-04 3.12E-04 3.35E-04 3.44E-04 3.44E-04 3.38E-04 3.29E-04 3.18E-04 UTERUS 23 2.62E-04 2.95E-04 3.16E-04 3.26E-04 3.26E-04 3.20E-04 3.12E-04 3.01E-04 THIYROID 10 2.61E-04 2.94E-04 3.15E-04 3.24E-04 3.24E-04 3.18E-04 3.10E-04 2.99E-04 BL WALL 19 2.48E-04 2.80E-04 3.00E-04 3.09E-04 3.09E-04 3.04E-04 2.95E-04 2.86E-04 SKIN 16 2.47E-04 2.78E-04 2.99E-04 3.07E-04 3.07E-04 3.02E-04 2.94E-04 2.84E-04 TESTES 6 2.35E-04 2.65E-04 2.84E-04 2.92E-04 2.92E-04 2.87E-04 2.80E-04 2.70E-04 BRAIN 17 2.31lE-04 2.60E-04 2.79E-04 2.87E-04 2.87E-04 2.82E-04 2.74E-04 2.65E-04
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09/29109 Rev. 2 Rev. 0 Page 42 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:05 PAGE 6
- Krypton MIHA Analysis INHALATION WEIGHTED COMMITTED DOSE EQUIVALENTS (remn)
DOWNWIND DISTANCES (in)
ORGAN NO. 8.00E+02 9.00E+02 1.00E+03 1.10E+03 1.20E+03 1.30E+03 1.40E+03 1.50E+03 LUNGS 1 3.32E-03 3.74E-03 4.01E-03 4.12E-03 4.12E-03 4.05E-03 3.94E-03 3.81E-03 S WALL 2 6.97E-04 7.85E-04 8.43E-04 8.67E-04 8.67E-04 8.52E-04 8.29E-04 8.01E-04 SI WALL 3 1.82E-05 2.06E-05 2.21E-05 2.27E-05 2.28E-05 2.24E-05 2.18E-05 2.11E-05 ULI WALL 4 2.22E-05 2.51lE-05 2.70E-05 2.78E-05 2.78E-05 2.74E-05 2.67E-05 2.59E-05 LLI WALL 5 2.81E-05 3.18E-05 3.42E-05 3.53E-05 3.54E-05 3.49E-05 3.40E-05 3.30E-05 TESTES 6 5.88E-05 6.62E-05 7.10E-05 7.31E-05 7.31E-05 7.18E-05 6.99E-05 6.75E-05 BREASTS 7 4.15E-05 4.68E-05 5.02E-05 5.16E-05 5.16E-05 5.08E-05 4.94E-05 4.77E-05 BONE STIR 8 8.45E-06 9.52E-06 1.02E-05 1.05E-05 1.05E-05 1.03E-05 1.01E-05 9.71E-06 RMIVARROW 9 3.40E-05 3.84E-05 4.12E-05 4.24E-05 4.24E-05 4.16E-05 4.05E-05 3.92E-05 THYROID 10 7.82E-06 8.81E-06 9.45E-06 9.72E-06 9.72E-06 9.55E-06 9.29E-06 8.98E-06 K]DNEYS 11 1.67E-05 1.88E-05 2.02E-05 2.07E-05 2.07E-05 2.04E-05 1.98E-05 1.92E-05 LIVER 12 1.86E-05 2.10E-05 2.25E-05 2.32E-05 2.32E-05 2.28E-05 2.22E-05 2.14E-05 SPLEEN 13 2.02E-05 2.28E-05 2.45E-05 2.52E-05 2.52E-05 2.47E-05 2.41E-05 2.33E-05 PANCREAS 14 2.32E-05 2.62E-05 2.81E-05 2.89E-05 2.89E-05 2.84E-05 2.77E-05 2.67E-05 MUSCLE 15 1.66E-05 1.87E-05 2.01E-05 2.07E-05 2.07E-05 2.03E-05 1.98E-05 1.91E-05 SKIN 16 2.47E-06 2.78E-06 2.99E-06 3.07E-06 3.07E-06 3.02E-06 2.94E-06 2.84E-06 BRAIN 17 1.38E-05 1.56E-05 1.67E-05 1.72E-05 1.72E-05 1.69E-05 1.64E-05 1.59E-05 TIIYMVUS 18 2.10E-05 2.36E-05 2.54E-05 2.61E-05 2.61E-05 2.56E-05 2.50E-05 2.41E-05 BL WALL 19 1.49E-05 1.68E-05 1.80E-05 1.85E-05 1.85E-05 1.82E-05 1.77E-05 1.71E-05 ADRENALS 20 1.82E-05 2.05E-05 2.20E-05 2.26E-05 2.26E-05 2.23E-05 2.17E-05 2.09E-05 ESOPIIAGU 21 2.10E-05 2.36E-05 2.54E-05 2.61E-05 2.61E-05 2.56E-05 2.50E-05 2.41E-05 OVARIES 22 7.05E-05 7.95E-05 8.54E-05 8.79E-05 8.79E-05 8.65E-05 8.42E-05 8.15E-05 UTERUS 23 1.57E-05 1.77E-05 1.90E-05 1.95E-05 1.95E-05 1.92E-05 1.87E-05 1.81E-05 CEDE 24 4.28E-03 4.82E-03 5.17E-03 5.32E-03 5.32E-03 5.23E-03 5.09E-03 4.92E-03
- GAMMA~ DOSE CALCULATION WITH EXPOSURE TIME = 7.1994E+03 (s)
CALCULATIONS MADE USING THE FINITE MODEL EXTERNAL EDE DOWNWIND DISTANCE = 8.000E+02 (in)
DOSE =2.73E-02 (rem)
DOWNWIND DISTANCE = 9.000E+02 (in)
DOSE-- 2.60E-02 (remn)
DOWNWIND DISTANCE = 1.000E+03 (in)
DOSE = 2.50E-02 (remn)
DOWNWIND DISTANCE = 1.100E+I03 (in)
DOSE = 2.40E-02 (remn)
DOWNWIND DISTANCE = 1.200E+03 (in)
DOSE =2.30E-02 (remn)
DOWNWIND DISTANCE = 1.300E+I03 (in)
DOSE =2.2 1E.-02 (rem)
DOWNWIND DISTANCE = 1.400E+03 (in)
DOE=21E0(rm DOSE = 2.12E-02 (rem)
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 43 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)"
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIMvE 08:05 PAGE 7
- Krypton MIA Analysis DOWNWINJD DISTANCE = 1.500E+03 (In)
DOSE = 2.03E-02 (rem)
EXECUTION time = 2.80E-01 SECONDS
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 44 of 59 RSAC-6 INPUT 20160121 07:58 0
1 2
3 4
5 6
7 123456789012345678901234567890123456789012345678901234567890 1234567890123456789
- Xenon MH-A Analysis
- Line replaced by WinRp to use temporary external file src 1.txt
- 2002,C:\\Users\\dthorne\\Documents\\Rsac\\Input Files\\Xenon_.2016.txt 2002,srcl.txt 2999
- F Stability and 2 rn/s 5000,0 5001,2.,22.86,400.,1240.,0.,0 5101, 10., 100.,200.,300.,430.,500.,600.,700.
5201,1.389E-4,0.
5400,2,0.,0.,0 5410,3,6,0 5999
- Dose Data 7000,0, -2,1,0,1 700 1,3.47E..04,0.,0,0,1.
7999
- Cloud Ganmma 9000,0,0.
10000 0
1 2
3 4
5 6
7 12345678901234567890123456789012345678901234567890 12345678901234567890123456789
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 45 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 07:58 PAGE 1
- Xenon MHA Analysis
- DlRECT RADIONUCLIDE INPUT ANY PREVIOUS INVENTORY HAS BEEN ZEROED NUJCLIDE HALF LIFE CURIES 541311 Xe131m 1.184E+01 d 1.840E+02 541330 Xe133 5.243E+00 d 4.030E+04 541331 Xe133m 2.190E+00 d 1.190E+l03 541350 Xe135 9.140E+00 h 3.020E+I04 541351 Xe135m 1.529E+01 m 2.810E+03
- METEOROLOGICAL DATA MEAN WIND SPEED = 2.000E+00 (mis) STACK HEIGHT = 2.286E+01 (in)
MIXING LAYER HEIGHT = 4.000E+02 (mn)
AIR DENSITY = 1.240E+03 (g/cu m)
WET DEPOSiTION SCAVENGING COEFFICIENT = 0.000E+00 (1/S)
NO CORRECTION IS BEING MADE FOR PLUME DEPLETION BY FALLOUT DEFAULT DRY DEPOSITION VELOCITIES (mis)
SOLIDS = 0.000E+00 HALOGENS =0.000E+00 NOBLE GASES =O.000E+00 CESIUM = 0.000E+00 RUTHENIUM =0.000E+-00 THERE IS 1 SET OF LEAKAGE CONSTANTS (K1,K2) 1.389E-04 0.000E+00 PASQUJILL CLASS F METEOROLOGY, P-G SIGMA VALUES WARNING - DIFFUSION FOR DISTANCES OF LESS THAN 100 METERS IS EXTRAPOLATED ENHANCED DEPOSITION PARAMETERS PARTICLE DIAMETER = 0.000E+00 (in) PARTICLE DENSITY = 0.000E+00 (g/cm3)
DOWNWIND DISTANCE STACK SIGY SIGZ CHIIQ HEIGHT (in)
(in)
(in)
(s/cu in) 1.000E+0 1 2.286E+0 1 5.776E-0 1 3.454E-0 1 0.000E+00 DOWNWIND DISTANCE STACK SIGY SIGZ CHI/Q HEIGHT (in)
(In)
(In)
(s/cu in) 1.O00E+02 2.286E+01 4.621E+00 2.247E+I00 5.171E-25
TEM-9002 09/29109 Rev. 0 ENGINEERING DESIGN FILE EDF-3124-0003 Rev. 2 Page 46 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 07:58 PAGE 2
- Xenon MiHA Analysis DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 2.000E+02 2.286E+0-1 8.642E+00 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 3.000E+I02 2.286E+01 1.246E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 4.300E+02 2.286E+01 1.725E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(mn) 5.000E+02 2.286E+01 1.977E+0I DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 6.000E+02 2.286E+01 2.331E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 7.000E+02 2.286E+01 2.679E+01 SIGY SIGZ CHJJQ (s/cu mn) 3.988E+00 3.376E-10 SIGY SIGZ CHIIQ (s/cu in) 5.506E+00 4.185E-07 SIGY SIGZ CHIIQ (s/cu mn) 7.293E+00 9.302E-06 SIGY SIGZ CHIIQ (s/cu in) 8.195E+00 2.008E-05 SIGY SIGZ CHI/Q (s/cu mn) 9.430E+00 3.834E-05 SIGY SIGZ CHIIQ (s/cu in) 1.061E+01 5.500E-05
- INHALATION DOSE EQUIVALENT CALCULATION USING DOSE CONVERSION FACTORS FROM FEDERAL GUIDANCE REPORT 11 RESPIRABLE FRACTION = 1.000E+f00 BREATHING RATE = 3.470E-04 (cu m/s)
RELEASE TIME FOR EXPONENTIAL DECAY FUNCTION = 7.199E+03 (s)
INTERNAL EXPOSURE TlIME PERIOD =5.000E+01 (yr)
PARTICLE SIZE =1.0 MICRON AMAD LUNG DEPOSITION FRACTIONS: N-P = 0.300 T-B = 0.080 P = 0.250 DEFAULT ELEMENT LUNG CLEARANCE CLASSES SELECTED TO GIVE MAXIMUM DOSE
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 47 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 07:58 PAGE 3
- Xenon MHA Analysis DOWNWIND DISTANCE =1.000E+01 (in)
PLUME TRAVEL TIME = 5.000E+00 (s)
CIIIQ =0.000E+00 (s/cu in)
DOWNWIND DISTANCE = 1.000E+02 (mn) PLUME TRAVEL TIME = 5.000E+01 (s)
CHIIQ = 5.171E-25 (s/cu mn)
DOWNWIND DISTANCE = 2.000E+02 (in)
PLUME TRAVEL TIME -- 1.000E+02 (s)
CHI/Q = 3.376E-10 (s/cu in)
DOWNWIND DISTANCE = 3.000E+02 (in)
PLUME TRAVEL TIME = 1.500E+02 (s)
CHIIQ = 4. 185E-07 (s/cu in)
DOWNWIND DISTANCE = 4.300E+02 (in)
PLUME TRAVEL TIME = 2.150E+02 (s)
CHI/IQ = 9.302E-06 (s/cu in)
DOWNWIND DISTANCE = 5.000E+02 (in)
PLUME TRAVEL TIME = 2.500E+02 (s)
CHI/Q =2.008E-05 (s/cu in)
DOWNWIND DISTANCE = 6.000E+02 (in)
PLUME TRAVEL TIME = 3.000E+02 (s)
CI{JQ = 3.83 4E-05 (s/cu in)
DOWNWIND DISTANCE = 7.000E+02 (in)
PLUME TRAVEL TIME = 3.500E+02 (s)
CHIIQ = 5.500E-05 (s/cu in)
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 48 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIMvE 07:58 PAGE 4
DOWNWIND DISTANCES (in)
ORGAN NO. 1.00E+0l 1.00E+02 2.00E+I02 3.00E+02 4.30E+02 5.00E+02 6.00E+02 7.00E+I02 LUNGS 1 0.00E+00 9.39E-31 6.21E-16 7.80E-13 1.76E-11 3.84E-11 7.42E-11 1.08E-10 S WALL 2 0.00E+00 8.06E-31 5.33E-16 6.69E-13 1.51E-11 3.30E-11 6.37E-11 9,25E-11 SIWALL 3 0.00E+i00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 ULI WALL 4 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 LLIWALL 5 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 TESTES 6 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 BREASTS 7 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 BONE SUR 8 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 RMIARROW 9 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 THYROID 10 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 KIDNEYS 11 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 LIVER 12 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 SPLEEN 13 0.00E+0-0 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 PANCREAS 14 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 MUSCLE 15 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-il 6.32E-11 9.18E-11 SKIN 16 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 THYMUS 18 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 BLWALL 19 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 ADRENALS 20 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 ESOPHAGU 21 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 OVARIES 22 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 UTERUS 23 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-11 ORGANS WITH NO CALCULATED DOSE HAVE BEEN SUPPRESSED FROM TABLE
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 49 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-.6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIMiE 07:58 PAGE 5
DOWNWIND DISTANCES (in)
ORGAN NO. 1.00E+01 1.00E+02 2.00E+I02 3.00E+02 4.30E+I02 5.00E+02 6.00E+02 7.00E+02 LUNGS 1 0.00E+00 9.39E-31 6.21E-16 7.80E-13 1.76E-11 3.84E-11 7.42E-11 1.08E-10 S WALL 2 0.00E+I00 8.06E-31 5.33E-16 6.69E-13 1.51lE-11 3.30E-11 6.37E-11 9.25E-l1 SIWALL 3 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-1l ULIWALL 4 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-ll LLIWALL 5 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.18E-ll TESTES 6 0.00E+0-0 7.99E-31 5.29E-16 6.64E-13 i.50E-11 3.27E-li 6.32E-11 9.18E-11 BREASTS 7 0.00E+i00 7.99E-31 5.29E-16 6.64E-13 l.50E-l1 3.27E-11 6.32E-11 9.18E-1l BONE SUR 8 0.00E+00 7.99E-31 5.29E-16 6.64E-13 l.50E-l1 3.2WE-il 6.32E-li 9.18E-1l RMARROW 9 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-l1 6.32E-11 9.18E-ll THYROID 10 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-li 6.32E-11 9.18E-ll KIDNEYS 11 0.00E+00 7.99E-31 5.29E-16 6.64E-13 l.50E-11 3.27E-li 6.32E-11 9.18E-l1 LIVER 12 0.00E+00 7.99E-31 5.29E-16 6.64E-13 l.50E-11 3.2WE-li 6.32E-11 9.18E-11 SPLEEN 13 0.00E+00 7.99E-31 5.29E-16 6.64E-13 i.50E-11 3.27E-l1 6.32E-I1 9.18E-II PANCREAS 14 0.00E+00 7.99E-31 5.29E-i6 6.64E-13 i.50E-11 3.2WE-il 6.32E-1l 9.18E-1i MUSCLE 15 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-il 6.32E-1i 9.18E-11 SKIN 16 0.00E+00 7.99E-31 5.29E-16 6.64E-i3 1.50E-li 3.27E-11 6.32E-11 9.18E-11 THYMVUS 18 0.00E+I00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-1i 6.32E-i1 9.i8E-11 BLWALL 19 0.00E+0-0 7.99E-31 5.29E-16 6.64E-i3 1.50E-11 3.27E-li 6.32E-i1 9.i8E-11 ADRENALS 20 0.00E+0-0 7.99E-31 5.29E-16 6.64E-i3 1.50E-11 3.2WE-1i 6.32E-i1 9.18E-11 ESOPIIAGU 21 0.00E+00 7.99E-3i 5.29E-16 6.64E-13 1.50E-1i 3.2WE-li 6.32E-i1 9.18E-11 OVARIES 22 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-11 3.27E-11 6.32E-11 9.i8E-11 UTERUS 23 0.00E+00 7.99E-31 5.29E-16 6.64E-13 1.50E-l1 3.2WE-1l 6.32E-11 9.18E-ll ORGANS WITH NO CALCULATED DOSE HAVE BEEN SUPPRESSED FROM TABLE
TEM-9002 ENGI NEERI NG DESIG N FI LE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 50 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC.-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 07:58 PAGE 6
- XenonMHA Analysis INHALATION WEIGHTED COMMITTED DOSE EQUIVALENTS (rem)
DOWNWIND DISTANCES (in)
ORGAN NO. 1.00E+01 1.00E+I02 2.00E+I02 3.00E+02 4.30E+02 5.00E+02 6.00E+02 7.00E+02 LUNGS 1 0.00E+00 1.13E-31 7.45E-17 9.36E-14 2.12E-12 4.61E-12 8.91E-12 1.29E-11 S WALL 2 0.00E+00 4.83E-32 3.20E-17 4.02E-14 9.08E-13 1.98E-12 3.82E-12 5.55E-12 UI WALL 4 0.00E+00 4.79E-32 3.17E-17 3.98E-14 9.00E-13 1.96E-12 3.79E-12 5.51E-12 LLI WALL 5 0.00E+00 4.79E-32 3.17E-17 3.98E-14 9.00E-13 1.96E-12 3.79E-12 5.51E-12 TESTES 6 0.00E+00 2.00E-31 1.32E-16 1.66E-13 3.75E-12 8.17E-12 1.58E-11 2.29E-11 BREASTS 7 0.00E+00 1.20E-31 7.93E-17 9.96E-14 2.25E-12 4.90E-12 9.48E-12 1.38E-11 BONE SUR 8 0.00E+I00 2.40E-32 1.59E-17 1.99E-14 4.50E-13 9.80E-13 1.90E-12 2.75E-12 RMARROW 9 0.00E+00 9.59E-32 6.34E-17 7.97E-14 1.80E-12 3.92E-12 7.58E-12 1.10E-11 THYROID 10 0.00E+0-0 2.40E-32 1.59E-17 1.99E-14 4.50E-13 9.80E-13 1.90E-12 2.75E-12 KID)NEYS 11 0.00E+00 4.79E-32 3.17E-17 3.98E-14 9.00E-13 1.96E-12 3.79E-12 5.51E-12 LIVER 12 0.00E+00 4.79E-32 3.17E-17 3.98E-14 9.00E-13 1.96E-12 3.79E-12 5.51E-12 SPLEEN 13 0.00E+00 4.79E-32 3.17E-17 3.98E-14 9.00E-13 1.96E-12 3.79E-12 5.51E-12 PANCREAS 14 0.00E+O0 4.79E-32 3.17E-17 3.98E-14 9.00E-13 1.96E-12 3.79E-12 5.51E-12 MUSCLE 15 0.00E+00 4.79E-32 3.17E-17 3.98E-14 9.00E-13 1.96E-12 3.79E-12 5.51lE-12 SKIN 16 0.00E+00 7.99E-33 5.29E-18 6.64E-15 1.50E-13 3.2'7E-13 6.32E-13 9.18E-13 THYMUS 18 0.00E+00 4.79E-32 3.17E-17 3.98E-14 9.00E-13 1.96E-12 3.79E-12 5.51E-12 BLWALL 19 0.00E+00 4.79E-32 3.17E-17 3.98E-14 9.00E-13 1.96E-12 3.79E-12 5.51E-12 ADRENALS 20 0.00E+00 4.79E-32 3.17E-17 3.98E-14 9.00E-13 1.96E-12 3.79E-12 5.51E-12 ESOPHAGU 21 0.00E+00 4.79E-32 3.17E-17 3.98E-14 9.00E-13 1.96E-12 3.79E-12 5.51E-12 OVARIES 22 0.00E+00 2.00E-31 1.32E-16 1.66E-13 3.75E-12 8.17E-12 1.58E-11 2.29E-11 UTERUS 23 0.00E+00 4.79E-32 3.17E-17 3.98E-14 9.00E-13 1.96E-12 3.79E-12 5.51E-12 CEDE 24 0.00E+00 8.19E-31 5.42E-16 6.80E-13 1.54E-11 3.35E-11 6.48E-11 9.41E-11 ORGANS WITH NO CALCULATED DOSE HAVE BEEN SUPPRESSED FROM TABLE
- GAMM DOSE CALCULATION WITH EXPOSURE TIME = 7.1994E+03 (s)
CALCULATIONS MADE USING THE FINITE MODEL EXTERNAL EDE DOWNWIND DISTANCE = 1.000E+01 (in)
DOSE -- 3.3 9E-02 (remn)
DOWNWIND DISTANCE = 1.000E+I02 (in)
DOSE = 6.54E-02 (rem)
DOWNW~IND DISTANCE = 2.O00E+02 (in)
DOSE = 6.30E-02 (rem)
DOWNWIND DISTANCE = 3.000E+02 (in)
DOSE -- 5.97E-02 (rem)
DOWNWIND DISTANCE = 4.300E+-02 (in)
DOSE = 5.65E-02 (rem)
DOWNWIND DISTANCE = 5.000E+02 (in)
DOWNWIND DISTANCE = 6.000E+02 (in)
DOSE = 5.34E-02 (rem)
DOWNWIND DISTANCE = 7.000E+02 (in)
DOE=52E2(rm DOSE = 5.12E-02 (rein)
TEM-9002 09129109 Rev. 0 ENGINEERING DESIGN FILE EDF-3124-0003 Rev. 2 Page 51 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC--6, REV 6.2, 03/11102) SERIAL 1 DATE 20160120 TIME 07:58 PAGE 7
- Xenon MITA Analysis EXECUTION time = 2.80E-01 SECONDS
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 52 of 59 RSAC-6 INPUT 20160121 08:01 0
1 2
3 4
5 6
7 123456789012345678901234567890123456789012345678901234567890 1234567890123456789
- Line replaced by WinRp to use temporary external fie srcl.txt
- 2002,C:\\Users\\dtliome\\Documents\\Rsac\\Input Files\\Xenon_2016.txt 2002,srcl.txt 2999
- F Stability and 2 m/s 5000,0 500 1,2.,22.86,400., 1240.,0.,0 5 101,800.,900., 1000., 1 100., 1200., 1300., 1400., 1500.
5201,1.389E-4,0.
5400,2,0.,0.,0 5410,3,6,0 5999
- Dose Data 7000,0, -2,1,0,1 7001,3.47E-04,0.,0,0,1.
7999
- Cloud Gamma 9000,0,0.
10000 0
1 2
3 4
5 6
7 123456789012345678901234567890123456789012345678901234567890 1234567890123456789
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129/09 Rev. 2 Rev. 0 Page 53 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:01 PAGE 1
- XenonMI-IA Analysis
- DIiRECT RADIONUCLIDE INPUT ANY PREVIOUS INVENTORY HAS BEEN ZEROED NUCLIDE HALF LIF~E CURIES 541311 Xel31m 1.184E+01 d l.840E+02 541330 Xe133 5.243E+00 d 4.030E+04 541331 Xel33m 2.190E+00 d 1.190E+03 541350 Xe135 9.140E+00 h 3.020E+04 541351 Xel35m 1.529E+01 m 2.810E+03
- METEOROLOGICAL DATA MEAN WIND SPEED = 2.000E+00 (m/s) STACK HEIGHT = 2.286E+01 (in)
MIXING LAYER HEIGHT =4.000E+02 (in)
AIR DENSITY =1.240E+03 (g/cu m)
WET DEPOSITION SCAVENGING COEFFICIENT = 0.000E+00 (l/S)
NO CORRECTION IS BEING MADE FOR PLUME DEPLETION BY FALLOUT DEFAULT DRY DEPOSITION VELOCITIES (mis)
SOLIDS = 0.000E+0-0 HALOGENS = 0.000E+00 NOBLE GASES = 0.000E+00 CESIUM = 0.000E+00 RUTHENIUM = 0.000E+-00 THERE IS 1 SET OF LEAKAGE CONSTANTS (K1,K2) 1.389E-04 0.000E+00 PASQUILL CLASS F METEOROLOGY, P-G SIGMA VALUES ENHANCED DEPOSITION PARAMETERS PARTICLE DIAMETER =0.000E-I00 (in) PARTICLE DENSITY = 0.000E+00 (g/cm3)
DOWNWIND DISTANCE STACK SIGY SIGZ CHIIQ H-EIGHT (mn) (in)
(in)
(s/cu m) 8.000E+02 2.286E+01O 3.022E+01 1.175E+01 6.754E-05 DOWNWIND DISTANCE STACK SIGY SIGZ CHI/Q HEIGHT (in)
(in)
(in)
(s/cu m) 9.000E+02 2.286E+0 1 3.361E+0 1 1.285E+01 7.574E-05
TEM-9002 09129109 Rev. 0 ENGINEERING DESIGN FILE ED F-3 124-0003 Rev. 2 Page 54 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:01 PAGE 2
- Xenon MHA Analysis DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(mn) 1.000E+i03 2.286E+01O 3.697E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 1.100E+I03 2.286E+I01 4.029E+0l DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 1.200E+03 2.286E+01 4.359E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 1.300E+03 2.286E+01 4.685E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 1.400E+03 2.286E+01 5.0l0E+01 DOWNWIND DISTANCE STACK HEIGHT (in)
(in)
(in) 1.500E+03 2.286E+01 5.332E+01 SIGY SIGZ CHI/Q (s/cu m) 1.399E+01 8.094E-05 SIGY SIGZ CHI/Q (s/cu mn) 1.507E+01I 8.294E-05 SIGY SIGZ CHI/Q (s/cu m) 1.607E+01 8.263E-05 SIGY SIGZ CHUiQ (s/cu mn) 1.701E+01O 8.095E-05 SIGY SIGZ CHIIQ (s/cu in) 1.789E+01 7.851E-05 SIGY SIGZ CHI-/Q (s/cu In) 1.872E+01 7.566E-05
- INHAL.ATION DOSE EQUIVALENT CALCULATION USING DOSE CONVERSION FACTORS FROM FEDERAL GUIDANCE REPORT 11 RESPIRABLE FRACTION = 1.000E+00 BREATHING RATE =3.470E-04 (cu mis)
RELEASE TIME FOR EXPONENTIAL DECAY FUNCTION = 7.199E+03 (s)
INTERNAL EXPOSURE TIME PERIOD = 5.000E+01 (yr)
PARTICLE SIZE = 1.0 MICRON AMAD LUNG DEPOSITION FRACTIONS: N-P = 0.300 T-B = 0.080 P = 0.250 DEFAULT ELEMENT LUNG CLEARANCE CLASSES SELECTED TO GIVE MAXIMUM DOSE
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 55 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC..6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIMvE 08:0 1PAGE 3
- Xenon MHA Analysis DOWNWIND DISTANCE = 8.000E+02 (in)
PLUME TRAVEL TIME = 4.000E+f02 (s)
CHI/Q = 6.754E-05 (s/cu mn)
DOWNWIND DISTANCE = 9.000E+02 (in)
PLUME TRAVEL TIME = 4.500E+02 (s)
CHI/Q =7.574E-05 (s/cu m)
DOWNWIND DISTANCE = 1.000E+03 (in)
PLUME TRAVEL TIME = 5.000E+02 (s)
CHII/Q = 8.0 94E-05 (s/cu in)
DOWNWIND DISTANCE = 1. 100E+03 (in)
PLUME TRAVEL TIME = 5.500E+02 (s)
CHIIQ = 8.294E-05 (s/cu in)
DOWNWIND DISTANCE = 1.200E+03 (in)
PLUME TRAVEL TIME = 6.000E+02 (s)
CHI/IQ = 8.263E-05 (s/cu in)
DOWNWIND DISTANCE = 1.300E+03 (in)
PLUME TRAVEL TIME = 6.500E+-02 (s)
CJHIIQ = 8.095E-05 (s/cu m)
DOWNWIh4D DISTANCE = 1.400E+03 (in)
PLUME TRAVEL TIME = 7.000E+02 (s)
CHI!Q = 7.851lE-05 (s/cu in)
DOWNWIND DISTANCE = 1.500E+03 (in)
PLUME TRAVEL TIME = 7.500E+02 (s)
CHI/Q = 7.566E-05 (s/cu in)
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 56 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:01 PAGE 4
- Xenon MEA Analysis INHALATION COMMUTIED DOSE EQUIVALENTS ORDERED BY ORGAN (rem)
DOWNWIND DISTANCES (in)
ORGAN NO. 8.00E+02 9.00E+02 1.00E+03 1.10E+03 1.20E+03 1.30E+03 1.40E+l03 1.50E+03 LUNGS 1 1.34E-10 1.52E-10 1.65E-10 1.71E-10 1.72E-10 1.70E-10 1.67E-10 1.63E-10 S WALL 2 L.15E-10 1.31IE-10 1.41E-10 1.46E-10 1.48E-10 1.46E-10 1.43E-10 1.40E-10 SI WALL 3 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-l0 ULIWALL 4 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 l.45E-10 1.42E-10 1.39E-10 LLI WALL 5 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 TESTES 6 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 BREASTS 7 l.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-l0 1.39E-10 BONE SUR 8 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 RMARROW 9 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 THYROID 10 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 KIDNEYS 11 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 LIVER 12 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 SPLEEN 13 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 PANCREAS 14 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 MUSCLE 15 1.14E-10 1L29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 I.39E-10 SKJN 16 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 THYMUS 18 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 BL WALL 19 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 ADRENALS 20 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-I0 1.39E-10 ESOPHAGU 21 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 OVARIES 22 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 UTERUS 23 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 ORGANS WITH NO CALCULATED DOSE HAVE BEEN SUPPRESSED FROM TABLE
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129/09 Rev. 2 Rev. 0 Page 57 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:01 PAGE 5
- XenonMHA Analysis INHALATION COMMITLTED DOSE EQUIVALENCES ORDERED BYDOSE (rem)
DOWNWIND DISTANCES (in)
ORGAN NO. 8.00E+f02 9.00E+02 1.00E+03 1.10E+03 l.20E+03 1.30E+03 1.40E+03 1.50E+03 LUNGS 1 1.34E-10 1.52E-10 1.65E-10 1.71E-10 1.72E-10 l.70E-10 1.67E-10 1.63E-10 S WALL 2 1.15E-10 1.31E-10 1.41E-10 1.46E-10 1.48E-10 1.46E-10 1.43E-10 1.40E-10 SIWALL 3 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 ULIWALL 4 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 LLIWALL 5 1.14E-l0 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 TESTES 6 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 BREASTS 7 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 BONE SUR 8 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 RMARROW 9 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 THYROID 10 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-l0 1.42E-10 1.39E-10 KIDNEYS 11 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 LIVER 12 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 SPLEEN 13 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 PANCREAS 14 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 MUSCLE 15 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 SKIN 16 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 TITYMUS 18 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-l0 BLWALL 19 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-l0 ADRENALS 20 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 ESOPHAGU 21 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 OVARIES 22 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 UTERUS 23 1.14E-10 1.29E-10 1.40E-10 1.45E-10 1.46E-10 1.45E-10 1.42E-10 1.39E-10 ORGANS WITH NO CALCULATED DOSE HAVE BEEN SUPPRESSED FROM TABLE
TEM-9002 ENGINEERING DESIGN FILE EDF-3124-0003 09129109 Rev. 2 Rev. 0 Page 58 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIME 08:01 PAGE 6
DOWNWIND DISTANCES (in)
ORGAN NO. 8.00E+02 9.00E+02 1.00E+03 1.10E+03 1.20E+03 1.30E+03 1.40E+03 1.50E+03 LUNGS 1 1.61E-11 1.83E-11 1.97E-11 2.05E-11 2.06E-11 2.04E-11 2.01E-11 1.95E-11 S WALL 2 6.90E-12 7.83E-12 8.47E-12 8.78E-12 8.85E-12 8.77E-12 8.60E-12 8.39E-12 SIWALL 3 6.84E-12 7.77E-12 8.40E-12 8.71E-12 8.78E-12 8.70E-12 8.53E-12 8.32E-12 ULI WALL 4 6.84E-12 7.77E-12 8.40E-12 8.71E-12 8.78E-12 8.70E-12 8.53E-12 8.32E-12 LUIWALL 5 6.84E-12 7.77E-12 8.40E-12 8.71E-12 8.78E-12 8.70E-12 8.53E-12 8.32E-12 TESTES 6 2.85E-11 3.24E-11 3.50E-11 3.63E-11 3.66E-11 3.62E-11 3.56E-11 3.47E-11 BREASTS 7 1.71E-11 1.94E-11 2.10E-11 2.18E-11 2.19E-11 2.17E-11 2.13E-11 2.08E-11 BONE SUR 8 3.42E-12 3.88E-12 4.20E-12 4.36E-12 4.39E-12 4.35E-12 4.27E-12 4.16E3-12 RMARROW 9 1.37E-11 1.55E-11 1.68E-11 1.74E-11 1.76E-11 1.74E-11 1.71E-11 1.66E-11 THYROID 10 3.42E-12 3.88E-12 4.20E-12 4.36E-12 4.39E-12 4.35E-12 4.27E-12 4.16E-12 KIDNEYS 11 6.84E-12 7.77E-12 8.40E-12 8.71E-12 8.78E-12 8.70E-12 8.53E-12 8.32E-12 LIVER 12 6.84E-12 7.77E-12 8.40E-12 8.71E-12 8.78E-12 8.70E-12 8.53E-12 8.32E-12 SPLEEN 13 6.84E-12 7.77E-12 8.40E-12 8.71E-12 8.78E-12 8.70E-12 8.53E-12 8.32E-12 PANCREAS 14 6.84E-12 7.77E-12 8.40E-12 8.71E-12 8.78E-12 8.70E-12 8.53E-12 8.32E-12 MUSCLE 15 6.84E-12 7.77E-12 8.40E-12 8.71E-12 8.78E-12 8.70E-12 8.53E-12 8.32E-12 SKIN 16 1.14E-12 1.29E-12 1.40E-12 I.45E-12 1.46E-12 1.45E-12 1.42E-12 1.39E-12 THYMUS 18 6.84E-12 7.77E-12 8.40E-12 8.71E-12 8.78E-12 8.70E-12 8.53E-12 8.32E-12 BL WALL 19 6.84E-12 7.77E-12 8.40E-12 8.71E-12 8.78E-12 8.70E-12 8.53E-12 8.32E-12 ADRENALS 20 6.84E-12 7.77E-12 8.40E-12 8.71E-12 8.78E-12 8.70E-12 8.53E-12 8.32E-12 ESOPIIAGU 21 6.84E-12 7.77E-12 8.40E-12 8.71E-12 8.78E-12 8.70E-12 8.53E-12 8.32E-12 OVARIES 22 2.85E-11 3.24E-11 3.50E-11 3.63E-11 3.66E-11 3.62E-11 3.56E-11 3.47E-11 UTERUS 23 6.84E-12 7.77E-12 8.40E-12 8.71E-12 8.78E-12 8.70E-12 8.53E-12 8.32E-12 CEDE 24 1.17E-10 1.33E-10 1.44E-10 1.49E-10 1.50E-10 1.49E-10 1.46E-10 1.42E-10 ORGANS WITH NO CALCULATED DOSE HAVE BEEN SUPPRESSED FROM TABLE
- GAMMA DOSE CALCULATION WITH EXPOSUR~E TIME = 7.1994E+03 (s)
CALCULATIONS MADE USING THE FINITE MODEL EXTERNAL EDE DOWNWIND DISTANCE = 8.000E+02 (in)
DOSE = 4.88E-02 (rem)
DOWNWIND DISTANCE =9.000E+02 (mn)
DOSE = 4.65E-02 (rem)
DOWNWIND DISTANCE =1.000E+I03 (mn)
DOSE = 4.47E-02 (rem)
DOWNWIND DISTANCE= 1.100E+03 (in)
DOSE = 4.28E-02 (rem)
DOWNWIND DISTANCE =l.200E+03 (in)
DOSE = 4.11E-02 (rem)
DOWNWIND DISTANCE =.300E+03 (mn)
DOSE = 3.94E-02 (rem)
DOWNWIND DISTANCE =.400E+03 (mn)
DOSE = 3.79E-02 (rein)
DOWNWIND DISTANCE =1.500E+03 (mn)
DOE=36E0(e)
DOSE = 3.63E-02 (rem)
TEM-9002 09129109 Rev. 0 ENGINEERING DESIGN FILE EDF-3124-0003 Rev. 2 Page 59 of 59 RADIOLOGICAL SAFETY ANALYSIS COMPUTER PROGRAM (RSAC-6)
(RSAC-6, REV 6.2, 03/11/02) SERIAL 1 DATE 20160120 TIMVE 08:01 PAGE 7
- Xenon MHA Analysis EXECUTION time = 2.80E-01 SECONDS