OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION
Enclosure transmitted herewith contains SUNSI. When separated from enclosure, this
transmittal document is decontrolled.
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION
January 27, 2016
Mr. Michael R. Chisum
Site Vice President
Entergy Operations, Inc.
17265 River Road
Killona, LA 70057-0751
SUBJECT: WATERFORD STEAM ELECTRIC STATION - NRC SECURITY
INSPECTION REPORT 05000382/2015407 AND NRC INVESTIGATION
REPORT NO. 4-2014-044 AND NOTICE OF VIOLATION
Dear Mr. Chisum:
This letter refers to the investigation conducted by the U.S. Nuclear Regulatory Commission's
Office of Investigations at the Waterford Steam Electric Station to determine if willful security-
related violations of NRC requirements occurred at the Waterford Steam Electric Station. The
investigation was initiated on August 21, 2014, and completed on August 18, 2015. The NRC
inspectors discussed the results of this inspection and investigation with Messrs. M. Chisum,
Site Vice President; J. Jarrell, Regulatory Assurance Manager and Acting Director, Regulatory
and Performance Improvement; A. James, Security Manager; and other members of your staff
on January 7, 2016. The inspectors documented the results of this inspection and investigation
in the enclosed inspection report.
Based on the results of this inspection and investigation, the NRC has determined that two
Severity Level IV violations of NRC requirements occurred.
These violations were evaluated in accordance with the NRC Enforcement Policy, which
appears on the NRCs Web site at http://www.nrc.gov/about-rc/regulatory/enforcement/enforce-
pol.html. The violations are cited in the enclosed Notice of Violation and the circumstances
surrounding them are described in detail in the subject inspection report. The violations are
being cited in the Notice of Violation because they involved the willful failure to comply with
regulatory requirements by several security officers.
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION
M. Chisum
- 2 -
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION
You are required to respond to this letter and should follow the instructions specified in the
enclosed Notice when preparing your response. If you have additional information that you
believe the NRC should consider, you may provide it in your response to the Notice. The NRCs
review of your response to the Notice will also determine whether further enforcement action is
necessary to ensure compliance with regulatory requirements.
However, the material enclosed herewith contains Security-Related Information in accordance
with 10 CFR 2.390(d)(1) and its disclosure to unauthorized individuals could present a security
vulnerability. Therefore, the material in the enclosure will not be made available electronically
for public inspection in the NRC Public Document Room or from the NRC's document system
(ADAMS), accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html.
If Security-Related Information is necessary to provide an acceptable response, please mark
your entire response Security-Related Information in accordance with 10 CFR 2.390(d)(1)
and follow the instructions for withholding in 10 CFR 2.390(b)(1). In accordance with
10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response.
Sincerely,
/RA/
Anton Vegel, Director
Division of Reactor Safety
Docket No. 50-382
License No. NPF-38
Nonpublic Enclosures:
1. Factual Summary of OI Investigation
Report No 4-2014-044
2. Inspection Report 05000382/2015407
cc w/o encl: Electronic Distribution
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION
M. Chisum
- 2 -
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION
You are required to respond to this letter and should follow the instructions specified in the
enclosed Notice when preparing your response. If you have additional information that you
believe the NRC should consider, you may provide it in your response to the Notice. The NRCs
review of your response to the Notice will also determine whether further enforcement action is
necessary to ensure compliance with regulatory requirements.
However, the material enclosed herewith contains Security-Related Information in accordance
with 10 CFR 2.390(d)(1) and its disclosure to unauthorized individuals could present a security
vulnerability. Therefore, the material in the enclosure will not be made available electronically
for public inspection in the NRC Public Document Room or from the NRC's document system
(ADAMS), accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html.
If Security-Related Information is necessary to provide an acceptable response, please mark
your entire response Security-Related Information in accordance with 10 CFR 2.390(d)(1)
and follow the instructions for withholding in 10 CFR 2.390(b)(1). In accordance with
10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response.
Sincerely,
/RA/
Anton Vegel, Director
Division of Reactor Safety
Docket No. 50-382
License No. NPF-38
Nonpublic Enclosures:
1. Factual Summary of OI Investigation
Report No 4-2014-044
2. Inspection Report 05000382/2015407
cc w/o encl: Electronic Distribution
DISTRIBUTION:
See next page
ADAMS ACCESSION NUMBER: ML16027A295
Entire Report w/encl.
SUNSI Review By: MSH
Non-Sensitive
Sensitive
Publicly Available
Non-Publicly Available
Keyword: NRC-002
MD 3.47 Non-Public A.3
Cover Letter Only w/o encl.
SUNSI Review By: MSH
Non-Sensitive
Sensitive
Publicly Available
Non-Publicly Available
Keyword: RGN-002
SUNSI Review Complete
OFFICE
PSI:PSB1
PSI:PSB1
C:PSB1
C:RPBA
ES:ACES
D:DRS
RC:RIV
NAME
AMeyen
RLanfear
M Haire
G Miller
C Maier
A Vegel
K Fuller
SIGNATURE
/RA/
/RA/
/RA/
/RA/
/RA/
/RA/
/RA/
DATE
12/23/15
12/23/15
12/31/15
1/6/16
1/7/16
1/11/16
1/13/16
OFFICE
D:DRS
NAME
D Furst
L Casey
S Coker
D Cylkowski
A Vegel
SIGNATURE
/RA/
/RA/
/RA/
/RA/
/RA/
DATE
1/26/16
1/25/16
1/25/16
1/26/16
1/27/16
OFFICIAL RECORD DOCUMENT
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION
Letter to Michael R. Chisum from Anton Vegel, dated January 27, 2016
SUBJECT: WATERFORD STEAM ELECTRIC STATION - NRC SECURITY
INSPECTION REPORT 05000382/2015407 AND NRC INVESTIGATION
REPORT NO. 4-2014-044 AND NOTICE OF VIOLATION
Electronic distribution w/enclosure:
Security Specialist/NSIR (Eric.Wharton@nrc.gov)
Security Specialist/NSIR (Niry.Simonian@nrc.gov)
Chief, Security Performance Evaluation Branch/NSIR (Clay.Johnson@nrc.gov)
Security Specialist/NSIR (Douglas.Garner@nrc.gov)
Branch Chief, RI DRS/PSB1 (Raymond.McKinley@nrc.gov)
Branch Chief, RII DRS/PSB1 (Binoy.Desai@nrc.gov)
Branch Chief, RIII DRS/PSB (Steven.Orth@nrc.gov)
Regional Administrator (Marc.Dapas@nrc.gov)
Deputy Regional Administrator (Kriss.Kennedy@nrc.gov)
DRP Director (Troy.Pruett@nrc.gov)
DRP Deputy Director (Ryan.Lantz@nrc.gov)
DRS Director (Anton.Vegel@nrc.gov)
DRS Deputy Director (Jeff.Clark@nrc.gov)
Senior Resident Inspector (Frances.Ramirez@nrc.gov)
Resident Inspector (Chris.Speer@nrc.gov)
Site Administrative Assistant (Linda.Dufrene@nrc.gov)
Branch Chief, DRS/PSB1 (Mark.Haire@nrc.gov)
Branch Chief, DRP/D (Jeffrey.Sowa@nrc.gov)
Senior Project Engineer, DRP/D (Bob.Hagar@nrc.gov)
Project Engineer, DRP/D (Jim.Melfi@nrc.gov)
Project Engineer, DRP/D (Jan.Tice@nrc.gov)
Enforcement Specialist, RIV (Christi.Maier@nrc.gov)
ACES (R4Enforcement.Resource@nrc.gov)
Electronic distribution by RIV w/o enclosure:
Public Affairs Officer (Victor.Dricks@nrc.gov)
Project Manager (April.Pulvirenti@nrc.gov)
Team Leader, DRS/IPAT (Thomas.Hipschman@nrc.gov)
RITS Coordinator (Marisa.Herrera@nrc.gov)
Regional Counsel (Karla.Fuller@nrc.gov)
Technical Support Assistant (Loretta.Williams@nrc.gov)
Senior Congressional Affairs Officer (Jenny.Weil@nrc.gov)
RIV Congressional Affairs Officer (Angel.Moreno@nrc.gov)
RIV/ETA: OEDO (Cindy.Rosales-Cooper@nrc.gov)
R4Allegation Resource
SAIC (Gayle.Walker@nrc.gov)
RSLO (Bill.Maier@nrc.gov)
RidsOeMailCenter Resource