January 19, 2016 Mr. Jeremy Browning, Site Vice President Arkansas Nuclear One Entergy Operations, Inc.
1448 SR 333 Russellville, AR 72802-0967
SUBJECT:
RESPONSE TO NOTIFICATION OF READINESS FOR SUPPLEMENTAL INSPECTION PROCEDURE 95003
Dear Mr. Browning:
The purpose of this letter is to inform you of the Nuclear Regulatory Commissions (NRC) current plans for conducting the applicable supplemental inspections required by the NRCs Reactor Oversight Process (ROP) and to respond to your inspection readiness letter dated January 15, 2016 (ADAMS ML16019A047).
By letter dated March 4, 2015 (ADAMS ML15063A499), the NRC notified you that Units 1 and 2 at Arkansas Nuclear One had been placed in the Multiple/Repetitive Degraded Cornerstone (Column 4) of the NRC Action Matrix for two Yellow findings on each unit. In that letter, the NRC notified you of our intent to conduct a supplemental inspection in accordance with Inspection Procedure (IP) 95003, Supplemental Inspection for Repetitive Degraded Cornerstones, Multiple Degraded Cornerstones, Multiple Yellow Inputs or One Red Input, once we receive written notification of your readiness for the inspection.
The NRC will conduct a supplemental inspection in accordance with IP 95002, Supplemental Inspection for One Degraded Cornerstone or Any Three White Inputs in a Strategic Performance Area, on each unit for each of the Yellow findings.
In addition, based on the performance indicator data for unplanned scrams for Unit 2 transitioning to White for the second and third quarters of 2014, the NRC will also conduct a supplemental inspection in accordance with IP 95001, Supplemental Inspection for One or Two White Inputs in a Strategic Performance Area.
These supplemental inspections will be performed onsite from January 25, 2016, through February 5, 2016, and February 22 through 26, 2016.
In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390, Public Inspections, Exemptions, Requests for Withholding, a copy of this letter, its enclosure, and your response (if any) will be available electronically for public inspection in the NRCs Public UNITED STATES NUCLEAR REGULATORY COMMISSION REGION IV 1600 E. LAMAR BLVD.
ARLINGTON, TX 76011-4511
Document Room or from the Publicly Available Records (PARS) component of the NRCs Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
Please contact me at 817-200-1574 with any questions concerning the details of these inspections.
Sincerely,
/RA/
Neil F. OKeefe, Chief Project Branch E Division of Reactor Projects Docket Nos: 50-313, 50-368 License Nos: DPR-51, NPF-6 cc: Electronic Distribution
ML16019A220 SUNSI Review By:
ADAMS Yes No Publicly Available Non-Publicly Available Non-Sensitive Sensitive Keyword:
NRC-002 OFFICE SPE:DRP/E C:DRP/E NAME JDixon NOKeefe SIGNATURE
/RA/
/RA/
DATE 1/19/16 1/19/16
Letter to Jeremy Browning from Neil OKeefe dated January 19, 2016
SUBJECT:
RESPONSE TO NOTIFICATION OF READINESS FOR SUPPLEMENTAL INSPECTION PROCEDURE 95003 Electronic distribution by RIV:
Regional Administrator (Marc.Dapas@nrc.gov)
Deputy Regional Administrator (Kriss.Kennedy@nrc.gov)
DRP Director (Troy.Pruett@nrc.gov)
DRP Deputy Director (Ryan.Lantz@nrc.gov)
DRS Director (Anton.Vegel@nrc.gov)
DRS Deputy Director (Jeff.Clark@nrc.gov)
Senior Resident Inspector (Brian.Tindell@nrc.gov)
Resident Inspector (Andy.Barrett@nrc.gov)
Resident Inspector (Margaret.Tobin@nrc.gov)
ANO Administrative Assistant (Mary.Bennett@nrc.gov)
Branch Chief, DRP/E (Neil.OKeefe@nrc.gov)
Senior Project Engineer (John.Dixon@nrc.gov)
Project Engineer (Brian.Correll@nrc.gov)
Project Engineer (Jackson.Choate@nrc.gov)
Public Affairs Officer (Victor.Dricks@nrc.gov)
Project Manager (Andrea.George@nrc.gov)
Team Leader, DRS/IPAT (Eric.Ruesch@nrc.gov)
RITS Coordinator (Marisa.Herrera@nrc.gov)
ACES (R4Enforcement.Resource@nrc.gov)
Regional Counsel (Karla.Fuller@nrc.gov)
Senior Congressional Affairs Officer (Jenny.Weil@nrc.gov)
Technical Support Assistant (Loretta.Williams@nrc.gov)
RIV Congressional Affairs Officer (Angel.Moreno@nrc.gov)
RIV/ETA: OEDO (Cindy.Rosales-Cooper@nrc.gov)
ROPassessment.Resource@nrc.gov ROPreports@nrc.gov
January 19, 2016 Mr. Jeremy Browning, Site Vice President Arkansas Nuclear One Entergy Operations, Inc.
1448 SR 333 Russellville, AR 72802-0967
SUBJECT:
RESPONSE TO NOTIFICATION OF READINESS FOR SUPPLEMENTAL INSPECTION PROCEDURE 95003
Dear Mr. Browning:
The purpose of this letter is to inform you of the Nuclear Regulatory Commissions (NRC) current plans for conducting the applicable supplemental inspections required by the NRCs Reactor Oversight Process (ROP) and to respond to your inspection readiness letter dated January 15, 2016 (ADAMS ML16019A047).
By letter dated March 4, 2015 (ADAMS ML15063A499), the NRC notified you that Units 1 and 2 at Arkansas Nuclear One had been placed in the Multiple/Repetitive Degraded Cornerstone (Column 4) of the NRC Action Matrix for two Yellow findings on each unit. In that letter, the NRC notified you of our intent to conduct a supplemental inspection in accordance with Inspection Procedure (IP) 95003, Supplemental Inspection for Repetitive Degraded Cornerstones, Multiple Degraded Cornerstones, Multiple Yellow Inputs or One Red Input, once we receive written notification of your readiness for the inspection.
The NRC will conduct a supplemental inspection in accordance with IP 95002, Supplemental Inspection for One Degraded Cornerstone or Any Three White Inputs in a Strategic Performance Area, on each unit for each of the Yellow findings.
In addition, based on the performance indicator data for unplanned scrams for Unit 2 transitioning to White for the second and third quarters of 2014, the NRC will also conduct a supplemental inspection in accordance with IP 95001, Supplemental Inspection for One or Two White Inputs in a Strategic Performance Area.
These supplemental inspections will be performed onsite from January 25, 2016, through February 5, 2016, and February 22 through 26, 2016.
In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390, Public Inspections, Exemptions, Requests for Withholding, a copy of this letter, its enclosure, and your response (if any) will be available electronically for public inspection in the NRCs Public UNITED STATES NUCLEAR REGULATORY COMMISSION REGION IV 1600 E. LAMAR BLVD.
ARLINGTON, TX 76011-4511
Document Room or from the Publicly Available Records (PARS) component of the NRCs Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
Please contact me at 817-200-1574 with any questions concerning the details of these inspections.
Sincerely,
/RA/
Neil F. OKeefe, Chief Project Branch E Division of Reactor Projects Docket Nos: 50-313, 50-368 License Nos: DPR-51, NPF-6 cc: Electronic Distribution
ML16019A220 SUNSI Review By:
ADAMS Yes No Publicly Available Non-Publicly Available Non-Sensitive Sensitive Keyword:
NRC-002 OFFICE SPE:DRP/E C:DRP/E NAME JDixon NOKeefe SIGNATURE
/RA/
/RA/
DATE 1/19/16 1/19/16
Letter to Jeremy Browning from Neil OKeefe dated January 19, 2016
SUBJECT:
RESPONSE TO NOTIFICATION OF READINESS FOR SUPPLEMENTAL INSPECTION PROCEDURE 95003 Electronic distribution by RIV:
Regional Administrator (Marc.Dapas@nrc.gov)
Deputy Regional Administrator (Kriss.Kennedy@nrc.gov)
DRP Director (Troy.Pruett@nrc.gov)
DRP Deputy Director (Ryan.Lantz@nrc.gov)
DRS Director (Anton.Vegel@nrc.gov)
DRS Deputy Director (Jeff.Clark@nrc.gov)
Senior Resident Inspector (Brian.Tindell@nrc.gov)
Resident Inspector (Andy.Barrett@nrc.gov)
Resident Inspector (Margaret.Tobin@nrc.gov)
ANO Administrative Assistant (Mary.Bennett@nrc.gov)
Branch Chief, DRP/E (Neil.OKeefe@nrc.gov)
Senior Project Engineer (John.Dixon@nrc.gov)
Project Engineer (Brian.Correll@nrc.gov)
Project Engineer (Jackson.Choate@nrc.gov)
Public Affairs Officer (Victor.Dricks@nrc.gov)
Project Manager (Andrea.George@nrc.gov)
Team Leader, DRS/IPAT (Eric.Ruesch@nrc.gov)
RITS Coordinator (Marisa.Herrera@nrc.gov)
ACES (R4Enforcement.Resource@nrc.gov)
Regional Counsel (Karla.Fuller@nrc.gov)
Senior Congressional Affairs Officer (Jenny.Weil@nrc.gov)
Technical Support Assistant (Loretta.Williams@nrc.gov)
RIV Congressional Affairs Officer (Angel.Moreno@nrc.gov)
RIV/ETA: OEDO (Cindy.Rosales-Cooper@nrc.gov)
ROPassessment.Resource@nrc.gov ROPreports@nrc.gov