December 11, 2015 UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE COMMISSION In the Matter of

)

)

SHINE MEDICAL TECHNOLOGIES, INC.

)

Docket No. M-50-608-CP

)

(Medical Radioisotope Production Facility)

)

)

REVISED NRC STAFF EXHIBIT LIST AND WITNESS LIST The U.S. Nuclear Regulatory Commission (NRC) staff (Staff) hereby files its revised exhibit list for the mandatory hearing on the construction permit application of SHINE Medical Technologies, Inc. (SHINE). The exhibit list is being revised to reflect the filing of a revision to Exhibit NRC-012, Staff Presentation Slides - Safety Panel 2, designated as NRC-012-R.

The revision is necessary to correct the fifth bullet on Slide 6, Safety Concept, of Exhibit NRC-012, which states, Emergency planning zone is the site boundary. The modified bullet states, Emergency planning zone could be the operational boundary. This modification is to accurately reflect, as stated in the Staffs Safety Evaluation Report, that (1) an Emergency Planning Zone (EPZ) need not be established before issuance of a construction permit and (2) consistent with the guidance in ANSI/ANS-15.16, an acceptable EPZ could be the operational boundary of the SHINE facility. Staff counsel informed Applicants counsel of the revision described above and Applicants counsel has no objection.

The Staff also hereby files a revised witness list for the mandatory hearing on SHINEs construction permit application. The witness list is being revised to correct a misspelling of a name (Down should be Downs) and to add one additional witness (John Adams). Staff counsel informed Applicants counsel of the revisions to the witness list and Applicants counsel has no objection.

Respectfully submitted,

/Signed (electronically) by/

Catherine E. Kanatas Counsel for NRC Staff U.S. Nuclear Regulatory Commission Office of the General Counsel Mail Stop O-14-G10 Washington, DC 20555 Telephone: (301) 415-2321 E-mail: Catherine.Kanatas@nrc.gov Executed in accord with 10 CFR 2.304(d)

Mitzi A. Young Counsel for NRC Staff U.S. Nuclear Regulatory Commission Office of the General Counsel Mail Stop O-14-G10 Washington, DC 20555 Telephone: (301) 415-3830 E-mail: Mitzi.Young@nrc.gov Dated at Rockville, Maryland this 11th day of December, 2015

Staff Exhibits for SHINE Mandatory Hearing Exhibit Number Panel Number/Sponsoring Witness(es)

Document Description/Title NRC-001 Mirela Gavrilas &

Jane Marshall SECY-15-0130, Staff Statement in Support of the Uncontested Hearing for Issuance of Construction Permit for the SHINE Medical Technologies, Inc.

Medical Radioisotope Production Facility (October 22, 2015), ADAMS Accession No. ML15272A004.

NRC-002 Mirela Gavrilas Draft Construction Permit for SHINE Medical Technologies, Inc. (December 8, 2015).

NRC-003 Jane Marshall Draft Record of Decision for SHINE Medical Technologies, Inc. Construction Permit Application (November 17, 2015), ADAMS Accession No. ML15272A019.

NRC-004-R Mirela Gavrilas &

Jane Marshall NRC Staff Responses to Commission Pre-Hearing Questions, (originally filed on November 24, 2015),

(revised December 8, 2015)

NRC-005 Mirela Gavrilas &

Jane Marshall NON-PUBLIC - NRC Staff Responses to Commission Pre-Hearing Questions, Non-public (filed on November 24, 2015), ADAMS Accession No. ML15328A545.

NRC-006A Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - Cover Letter and General and Financial Information (March 26, 2013), ADAMS Accession No. ML13088A192.

NRC-006B Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - Updated General Information (September 16, 2015), ADAMS Accession No. ML15259A272.

NRC-006C Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - Preliminary Safety Analysis Report (PSAR), beginning through Chapter 2, Figure 2.3-36 (August 27, 2015), ADAMS Accession Nos.

ML15258A389, ML15258A369, ML15258A370, ML15258A390, ML15258A391, ML15258A392, ML15258A393.

NRC-006D Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - [PSAR], Chapter 2, Figure 2.4-1 through Figure 2.4-11 (August 27, 2015), ADAMS Accession No. ML15258A395.

NRC-006E Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - [PSAR], Chapter 2, Figure 2.5-1 through Figure 2.5-6 (August 27, 2015), ADAMS Accession No. ML15258A396.

Exhibit Number Panel Number/Sponsoring Witness(es)

Document Description/Title NRC-006F Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - [PSAR], Chapter 2, Figure 2.5-7 through Figure 2.5-23 (August 27, 2015), ADAMS Accession No. ML15258A398.

NRC-006G Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - [PSAR], Chapter 3 through Chapter 18 (August 27, 2015), ADAMS Accession Nos. ML15258A371, ML15258A372, ML15258A373, ML15258A374, ML15258A375, ML15258A376, ML15258A377, ML15258A378. ML15258A379, ML15258A380, ML15258A381, ML15258A382, ML15258A383, ML15258A384, ML15258A385, ML15258A386, ML15258A387, ML15258A388, ML15258A399, ML15258A400, ML15258A402, ML15258A403, ML15258A404, ML15258A405, ML15258A406, ML15258A407, ML15258A408, ML15258A409, ML15258A410, ML15258A411.

NRC-006H Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - Environmental Report, [PSAR]

Chapter 19, beginning through end of text and Chapter 19, Figure 19.2.1-1 through Figure 19.2.3-1 (August 27, 2015), ADAMS Accession Nos.

ML15258A419, ML15258A412, ML15258A413, ML15258A414, ML15258A415, ML15258A416, ML15258A417, ML15258A418, ML15258A420.

NRC-006J1 Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - Environmental Report, [PSAR]

Chapter 19, Figure 19.3.1-1 through Figure 19.3.1-6 (August 27, 2015), ADAMS Accession No. ML15258A421.

NRC-006K Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - Environmental Report, [PSAR]

Chapter 19 Figure 19.3.1-7 through Figure 19.3.1-9 (August 27, 2015), ADAMS Accession No. ML15258A422.

NRC-006L Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - Environmental Report, [PSAR]

Chapter 19, Figure 19.3.2-1 through Figure 19.3.2-36 (August 27, 2015), ADAMS Accession No. ML15258A423.

NRC-006M Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - Environmental Report, [PSAR]

Chapter 19, Figure 19.3.3-1 through Figure 19.3.3-7 (August 27, 2015), ADAMS Accession No. ML15258A424.

1 The letter I was skipped to avoid potential confusion with the number 1.

Exhibit Number Panel Number/Sponsoring Witness(es)

Document Description/Title NRC-006N Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - Environmental Report, Chapter 19 Figure 19.3.4-1 to Chapter 19 Figure 19.3.4-8 (August 27, 2015), ADAMS Accession No. ML15258A426.

NRC-006O Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - Environmental Report, [PSAR]

Chapter 19 Figure 19.3.5-1 through Figure 19.3.8-2 (August 27, 2015), ADAMS Accession No. ML15258A427.

NRC-006P Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - Environmental Report, [PSAR]

Chapter 19 Figure 19.4.1-1 through Figure 19.4.13-1 (August 27, 2015), ADAMS Accession No. ML15258A428.

NRC-006Q Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - Environmental Report, [PSAR]

Chapter 19, Figure 19.5.2-1 through Figure 19.5.2-5 (August 27, 2015), ADAMS Accession No. ML15258A429.

NRC-006R Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - Environmental Report, [PSAR]

Chapter 19, Figure 19.5.2-6 through Figure 19.5.2-9 (August 27, 2015), ADAMS Accession No. ML15258A430.

NRC-007A Mirela Gavrilas NON-PUBLIC - SHINE Medical Technologies, Inc., Construction Permit Application - General and Financial Information, Non-public (March 26, 2013), ADAMS Accession No. ML13088A193.

NRC-007B Mirela Gavrilas NON-PUBLIC - SHINE Medical Technologies, Inc., Construction Permit Application - [PSAR],

beginning through Chapter 3 (August 27, 2015),

ADAMS Accession Nos. ML15258A332, ML15258A322, ML15258A323, ML15258A324, ML15258A333, ML15258A334.

NRC-007C Mirela Gavrilas NON-PUBLIC - SHINE Medical Technologies, Inc., Construction Permit Application -

[PSAR],and Environmental Report, [PSAR]

Chapter 4 through Chapter 19 (August 27, 2015),

ADAMS Accession Nos. ML15258A325, ML15258A326, ML15258A327, ML15258A328, ML15258A329, ML15258A330, ML15258A331, ML15258A335, ML15258A336, ML15258A337, ML15258A338, ML15258A339, ML15258A340, ML15258A341, ML15258A342, ML15258A343.

Exhibit Number Panel Number/Sponsoring Witness(es)

Document Description/Title NRC-007D Mirela Gavrilas NON-PUBLIC - SHINE Medical Technologies, Inc., Construction Permit Application -

Preliminary Emergency Plan (September 25, 2013), ADAMS Accession No. ML13269A379.

NRC-008 Mirela Gavrilas Safety Evaluation Report related to SHINE Medical Technologies, Inc. Construction Permit Application for a Medial Radioisotope Production Facility, (revised December 8, 2015)

NRC-009 Jane Marshall NUREG-2183, Final Environmental Impact Statement for the Construction Permit for the SHINE Medical Radioisotope Production Facility (October 16, 2015), ADAMS Accession No. ML15288A046.

NRC-010 Mirela Gavrilas &

Jane Marshall Staff Presentation Slides - Overview (December 8, 2015).

NRC-011 Mirela Gavrilas Staff Presentation Slides - Safety Panel 1 (December 8, 2015).

NRC-012-R Mirela Gavrilas Staff Presentation Slides - Safety Panel 2 (December 8, 2015, Corrected Exhibit Filed December 11, 2015).

NRC-013 Jane Marshall Staff Presentation Slides - Environmental Panel (December 8, 2015).

NRC Staff Witness List for SHINE Construction Permit Hearing Safety Witness Staff Office Alexander Adams Office of Nuclear Reactor Regulation John Adams Office of Nuclear Reactor Regulation Mary Adams Office of Nuclear Material Safety and Safeguards Stephen Alexander Information Systems Laboratories David Back Information Systems Laboratories Marissa Bailey Office of Nuclear Material Safety and Safeguards Daniel Barss Office of Nuclear Security and Incident Response Thomas Boyle Office of Regulatory Research Gregory Chapman Office of Nuclear Material Safety and Safeguards Jorge Cintron-Rivera Office of Nuclear Material Safety and Safeguards William Dean Office of Nuclear Reactor Regulation James Downs Office of Nuclear Material Safety and Safeguards Thomas Essig Information Systems Laboratories Mirela Gavrilas Office of Nuclear Reactor Regulation Mary Gitnick Information Systems Laboratories James Hammelman Office of Nuclear Material Safety and Safeguards Shawn Harwell Office of Nuclear Reactor Regulation Christopher Heysel Information Systems Laboratories Gregory Hofer Information Systems Laboratories Anthony Huffert Office of Regulatory Research Steven Lynch Office of Nuclear Reactor Regulation Stephen Marschke Information Systems Laboratories James Mcllvaine Information Systems Laboratories Diane Mlynarczyk Information Systems Laboratories Kevin Morrissey Office of Nuclear Material Safety and Safeguards Thomas Pham Office of Nuclear Material Safety and Safeguards Paul Prescott Office of New Reactors Michael Salay Office of Regulatory Research Alexander Sapountzis Office of Nuclear Security and Incident Response Raymond Skarda Office of Regulatory Research Soly Soto-Lugo Office of Nuclear Material Safety and Safeguards Joseph Staudenmeier Office of Regulatory Research Christopher Tripp Office of Nuclear Material Safety and Safeguards Glenn Tuttle Office of Nuclear Material Safety and Safeguards Carl Weber Office of New Reactors Abraham Weitzberg Information Systems Laboratories Environmental Witness Staff Office Kevin Folk Office of Nuclear Reactor Regulation Robert Hoffman Office of Nuclear Reactor Regulation Jane Marshall Office of Nuclear Reactor Regulation Nancy Martinez Office of Nuclear Reactor Regulation Michelle Moser Office of Nuclear Reactor Regulation Jeffrey Rikhoff Office of Nuclear Reactor Regulation

William Rautzen Office of Nuclear Reactor Regulation David Wrona Office of Nuclear Reactor Regulation

UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE COMMISSION In the Matter of

)

)

SHINE MEDICAL TECHNOLOGIES, INC.

)

Docket No. M-50-608-CP

)

(Medical Radioisotope Production Facility)

)

)

CERTIFICATE OF SERVICE Pursuant to 10 C.F.R. § 2.305, I hereby certify that copies of the foregoing NRC STAFF REVISED EXHIBIT LIST AND WITNESS LIST, dated December 11, 2015, and Exhibit NRC-012-R have been served upon the Electronic Information Exchange, the NRCs E-Filing System, in the above-captioned proceeding, this 11th day of December, 2015.

/Signed (electronically) by/

Catherine E. Kanatas Counsel for NRC Staff U.S. Nuclear Regulatory Commission Office of the General Counsel Mail Stop O-14-G10 Washington, DC 20555 Telephone: (301) 415-2321 E-mail: Catherine.Kanatas@nrc.gov Dated at Rockville, Maryland this 11th day of December, 2015

December 11, 2015 UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE COMMISSION In the Matter of

)

)

SHINE MEDICAL TECHNOLOGIES, INC.

)

Docket No. M-50-608-CP

)

(Medical Radioisotope Production Facility)

)

)

REVISED NRC STAFF EXHIBIT LIST AND WITNESS LIST The U.S. Nuclear Regulatory Commission (NRC) staff (Staff) hereby files its revised exhibit list for the mandatory hearing on the construction permit application of SHINE Medical Technologies, Inc. (SHINE). The exhibit list is being revised to reflect the filing of a revision to Exhibit NRC-012, Staff Presentation Slides - Safety Panel 2, designated as NRC-012-R.

The revision is necessary to correct the fifth bullet on Slide 6, Safety Concept, of Exhibit NRC-012, which states, Emergency planning zone is the site boundary. The modified bullet states, Emergency planning zone could be the operational boundary. This modification is to accurately reflect, as stated in the Staffs Safety Evaluation Report, that (1) an Emergency Planning Zone (EPZ) need not be established before issuance of a construction permit and (2) consistent with the guidance in ANSI/ANS-15.16, an acceptable EPZ could be the operational boundary of the SHINE facility. Staff counsel informed Applicants counsel of the revision described above and Applicants counsel has no objection.

The Staff also hereby files a revised witness list for the mandatory hearing on SHINEs construction permit application. The witness list is being revised to correct a misspelling of a name (Down should be Downs) and to add one additional witness (John Adams). Staff counsel informed Applicants counsel of the revisions to the witness list and Applicants counsel has no objection.

Respectfully submitted,

/Signed (electronically) by/

Catherine E. Kanatas Counsel for NRC Staff U.S. Nuclear Regulatory Commission Office of the General Counsel Mail Stop O-14-G10 Washington, DC 20555 Telephone: (301) 415-2321 E-mail: Catherine.Kanatas@nrc.gov Executed in accord with 10 CFR 2.304(d)

Mitzi A. Young Counsel for NRC Staff U.S. Nuclear Regulatory Commission Office of the General Counsel Mail Stop O-14-G10 Washington, DC 20555 Telephone: (301) 415-3830 E-mail: Mitzi.Young@nrc.gov Dated at Rockville, Maryland this 11th day of December, 2015

Staff Exhibits for SHINE Mandatory Hearing Exhibit Number Panel Number/Sponsoring Witness(es)

Document Description/Title NRC-001 Mirela Gavrilas &

Jane Marshall SECY-15-0130, Staff Statement in Support of the Uncontested Hearing for Issuance of Construction Permit for the SHINE Medical Technologies, Inc.

Medical Radioisotope Production Facility (October 22, 2015), ADAMS Accession No. ML15272A004.

NRC-002 Mirela Gavrilas Draft Construction Permit for SHINE Medical Technologies, Inc. (December 8, 2015).

NRC-003 Jane Marshall Draft Record of Decision for SHINE Medical Technologies, Inc. Construction Permit Application (November 17, 2015), ADAMS Accession No. ML15272A019.

NRC-004-R Mirela Gavrilas &

Jane Marshall NRC Staff Responses to Commission Pre-Hearing Questions, (originally filed on November 24, 2015),

(revised December 8, 2015)

NRC-005 Mirela Gavrilas &

Jane Marshall NON-PUBLIC - NRC Staff Responses to Commission Pre-Hearing Questions, Non-public (filed on November 24, 2015), ADAMS Accession No. ML15328A545.

NRC-006A Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - Cover Letter and General and Financial Information (March 26, 2013), ADAMS Accession No. ML13088A192.

NRC-006B Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - Updated General Information (September 16, 2015), ADAMS Accession No. ML15259A272.

NRC-006C Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - Preliminary Safety Analysis Report (PSAR), beginning through Chapter 2, Figure 2.3-36 (August 27, 2015), ADAMS Accession Nos.

ML15258A389, ML15258A369, ML15258A370, ML15258A390, ML15258A391, ML15258A392, ML15258A393.

NRC-006D Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - [PSAR], Chapter 2, Figure 2.4-1 through Figure 2.4-11 (August 27, 2015), ADAMS Accession No. ML15258A395.

NRC-006E Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - [PSAR], Chapter 2, Figure 2.5-1 through Figure 2.5-6 (August 27, 2015), ADAMS Accession No. ML15258A396.

Exhibit Number Panel Number/Sponsoring Witness(es)

Document Description/Title NRC-006F Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - [PSAR], Chapter 2, Figure 2.5-7 through Figure 2.5-23 (August 27, 2015), ADAMS Accession No. ML15258A398.

NRC-006G Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - [PSAR], Chapter 3 through Chapter 18 (August 27, 2015), ADAMS Accession Nos. ML15258A371, ML15258A372, ML15258A373, ML15258A374, ML15258A375, ML15258A376, ML15258A377, ML15258A378. ML15258A379, ML15258A380, ML15258A381, ML15258A382, ML15258A383, ML15258A384, ML15258A385, ML15258A386, ML15258A387, ML15258A388, ML15258A399, ML15258A400, ML15258A402, ML15258A403, ML15258A404, ML15258A405, ML15258A406, ML15258A407, ML15258A408, ML15258A409, ML15258A410, ML15258A411.

NRC-006H Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - Environmental Report, [PSAR]

Chapter 19, beginning through end of text and Chapter 19, Figure 19.2.1-1 through Figure 19.2.3-1 (August 27, 2015), ADAMS Accession Nos.

ML15258A419, ML15258A412, ML15258A413, ML15258A414, ML15258A415, ML15258A416, ML15258A417, ML15258A418, ML15258A420.

NRC-006J1 Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - Environmental Report, [PSAR]

Chapter 19, Figure 19.3.1-1 through Figure 19.3.1-6 (August 27, 2015), ADAMS Accession No. ML15258A421.

NRC-006K Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - Environmental Report, [PSAR]

Chapter 19 Figure 19.3.1-7 through Figure 19.3.1-9 (August 27, 2015), ADAMS Accession No. ML15258A422.

NRC-006L Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - Environmental Report, [PSAR]

Chapter 19, Figure 19.3.2-1 through Figure 19.3.2-36 (August 27, 2015), ADAMS Accession No. ML15258A423.

NRC-006M Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - Environmental Report, [PSAR]

Chapter 19, Figure 19.3.3-1 through Figure 19.3.3-7 (August 27, 2015), ADAMS Accession No. ML15258A424.

1 The letter I was skipped to avoid potential confusion with the number 1.

Exhibit Number Panel Number/Sponsoring Witness(es)

Document Description/Title NRC-006N Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - Environmental Report, Chapter 19 Figure 19.3.4-1 to Chapter 19 Figure 19.3.4-8 (August 27, 2015), ADAMS Accession No. ML15258A426.

NRC-006O Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - Environmental Report, [PSAR]

Chapter 19 Figure 19.3.5-1 through Figure 19.3.8-2 (August 27, 2015), ADAMS Accession No. ML15258A427.

NRC-006P Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - Environmental Report, [PSAR]

Chapter 19 Figure 19.4.1-1 through Figure 19.4.13-1 (August 27, 2015), ADAMS Accession No. ML15258A428.

NRC-006Q Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - Environmental Report, [PSAR]

Chapter 19, Figure 19.5.2-1 through Figure 19.5.2-5 (August 27, 2015), ADAMS Accession No. ML15258A429.

NRC-006R Mirela Gavrilas SHINE Medical Technologies, Inc., Construction Permit Application - Environmental Report, [PSAR]

Chapter 19, Figure 19.5.2-6 through Figure 19.5.2-9 (August 27, 2015), ADAMS Accession No. ML15258A430.

NRC-007A Mirela Gavrilas NON-PUBLIC - SHINE Medical Technologies, Inc., Construction Permit Application - General and Financial Information, Non-public (March 26, 2013), ADAMS Accession No. ML13088A193.

NRC-007B Mirela Gavrilas NON-PUBLIC - SHINE Medical Technologies, Inc., Construction Permit Application - [PSAR],

beginning through Chapter 3 (August 27, 2015),

ADAMS Accession Nos. ML15258A332, ML15258A322, ML15258A323, ML15258A324, ML15258A333, ML15258A334.

NRC-007C Mirela Gavrilas NON-PUBLIC - SHINE Medical Technologies, Inc., Construction Permit Application -

[PSAR],and Environmental Report, [PSAR]

Chapter 4 through Chapter 19 (August 27, 2015),

ADAMS Accession Nos. ML15258A325, ML15258A326, ML15258A327, ML15258A328, ML15258A329, ML15258A330, ML15258A331, ML15258A335, ML15258A336, ML15258A337, ML15258A338, ML15258A339, ML15258A340, ML15258A341, ML15258A342, ML15258A343.

Exhibit Number Panel Number/Sponsoring Witness(es)

Document Description/Title NRC-007D Mirela Gavrilas NON-PUBLIC - SHINE Medical Technologies, Inc., Construction Permit Application -

Preliminary Emergency Plan (September 25, 2013), ADAMS Accession No. ML13269A379.

NRC-008 Mirela Gavrilas Safety Evaluation Report related to SHINE Medical Technologies, Inc. Construction Permit Application for a Medial Radioisotope Production Facility, (revised December 8, 2015)

NRC-009 Jane Marshall NUREG-2183, Final Environmental Impact Statement for the Construction Permit for the SHINE Medical Radioisotope Production Facility (October 16, 2015), ADAMS Accession No. ML15288A046.

NRC-010 Mirela Gavrilas &

Jane Marshall Staff Presentation Slides - Overview (December 8, 2015).

NRC-011 Mirela Gavrilas Staff Presentation Slides - Safety Panel 1 (December 8, 2015).

NRC-012-R Mirela Gavrilas Staff Presentation Slides - Safety Panel 2 (December 8, 2015, Corrected Exhibit Filed December 11, 2015).

NRC-013 Jane Marshall Staff Presentation Slides - Environmental Panel (December 8, 2015).

NRC Staff Witness List for SHINE Construction Permit Hearing Safety Witness Staff Office Alexander Adams Office of Nuclear Reactor Regulation John Adams Office of Nuclear Reactor Regulation Mary Adams Office of Nuclear Material Safety and Safeguards Stephen Alexander Information Systems Laboratories David Back Information Systems Laboratories Marissa Bailey Office of Nuclear Material Safety and Safeguards Daniel Barss Office of Nuclear Security and Incident Response Thomas Boyle Office of Regulatory Research Gregory Chapman Office of Nuclear Material Safety and Safeguards Jorge Cintron-Rivera Office of Nuclear Material Safety and Safeguards William Dean Office of Nuclear Reactor Regulation James Downs Office of Nuclear Material Safety and Safeguards Thomas Essig Information Systems Laboratories Mirela Gavrilas Office of Nuclear Reactor Regulation Mary Gitnick Information Systems Laboratories James Hammelman Office of Nuclear Material Safety and Safeguards Shawn Harwell Office of Nuclear Reactor Regulation Christopher Heysel Information Systems Laboratories Gregory Hofer Information Systems Laboratories Anthony Huffert Office of Regulatory Research Steven Lynch Office of Nuclear Reactor Regulation Stephen Marschke Information Systems Laboratories James Mcllvaine Information Systems Laboratories Diane Mlynarczyk Information Systems Laboratories Kevin Morrissey Office of Nuclear Material Safety and Safeguards Thomas Pham Office of Nuclear Material Safety and Safeguards Paul Prescott Office of New Reactors Michael Salay Office of Regulatory Research Alexander Sapountzis Office of Nuclear Security and Incident Response Raymond Skarda Office of Regulatory Research Soly Soto-Lugo Office of Nuclear Material Safety and Safeguards Joseph Staudenmeier Office of Regulatory Research Christopher Tripp Office of Nuclear Material Safety and Safeguards Glenn Tuttle Office of Nuclear Material Safety and Safeguards Carl Weber Office of New Reactors Abraham Weitzberg Information Systems Laboratories Environmental Witness Staff Office Kevin Folk Office of Nuclear Reactor Regulation Robert Hoffman Office of Nuclear Reactor Regulation Jane Marshall Office of Nuclear Reactor Regulation Nancy Martinez Office of Nuclear Reactor Regulation Michelle Moser Office of Nuclear Reactor Regulation Jeffrey Rikhoff Office of Nuclear Reactor Regulation

William Rautzen Office of Nuclear Reactor Regulation David Wrona Office of Nuclear Reactor Regulation

UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE COMMISSION In the Matter of

)

)

SHINE MEDICAL TECHNOLOGIES, INC.

)

Docket No. M-50-608-CP

)

(Medical Radioisotope Production Facility)

)

)

CERTIFICATE OF SERVICE Pursuant to 10 C.F.R. § 2.305, I hereby certify that copies of the foregoing NRC STAFF REVISED EXHIBIT LIST AND WITNESS LIST, dated December 11, 2015, and Exhibit NRC-012-R have been served upon the Electronic Information Exchange, the NRCs E-Filing System, in the above-captioned proceeding, this 11th day of December, 2015.

/Signed (electronically) by/

Catherine E. Kanatas Counsel for NRC Staff U.S. Nuclear Regulatory Commission Office of the General Counsel Mail Stop O-14-G10 Washington, DC 20555 Telephone: (301) 415-2321 E-mail: Catherine.Kanatas@nrc.gov Dated at Rockville, Maryland this 11th day of December, 2015