1 NRR-PMDAPEm Resource From:

Jackson, Diane Sent:

Thursday, December 03, 2015 2:52 PM To:

Wyman, Stephen Cc:

Tseng, Ian; Chokshi, Nilesh; Jackson, Diane; Devlin-Gill, Stephanie; Shams, Mohamed

Subject:

Duke Audit Final Audit Report.docx Attachments:

Duke Audit Final Audit Report.docx Steve -

Finally - at last, please find attached our changes and updates to the audit summary. Also, when do we expect the Oconee submittal in?

Thanks -

Diane Diane Jackson, Chief Geosciences and Geotechnical Engineering Branch 2 (RGS2)

Division of Site Safety and Environmental Analysis (DSEA), Office of New Reactors (NRO)

US Nuclear Regulatory Commission

+1 301-415-5641; office: T-7 D3; mail stop: T-7 F3 NRC - One Team - One Mission

Hearing Identifier:

NRR_PMDA Email Number:

2543 Mail Envelope Properties (bd19511a1b3a499ebe4f9b16d33b16c4)

Subject:

Duke Audit Final Audit Report.docx Sent Date:

12/3/2015 2:51:54 PM Received Date:

12/3/2015 2:51:56 PM From:

Jackson, Diane Created By:

Diane.Jackson@nrc.gov Recipients:

"Tseng, Ian" <Ian.Tseng@nrc.gov>

Tracking Status: None "Chokshi, Nilesh" <Nilesh.Chokshi@nrc.gov>

Tracking Status: None "Jackson, Diane" <Diane.Jackson@nrc.gov>

Tracking Status: None "Devlin-Gill, Stephanie" <Stephanie.Devlin-Gill@nrc.gov>

Tracking Status: None "Shams, Mohamed" <Mohamed.Shams@nrc.gov>

Tracking Status: None "Wyman, Stephen" <Stephen.Wyman@nrc.gov>

Tracking Status: None Post Office:

HQPWMSMRS07.nrc.gov Files Size Date & Time MESSAGE 467 12/3/2015 2:51:56 PM Duke Audit Final Audit Report.docx 2106208 Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received:

1 NUCLEAR REGULATORY COMMISSION AUDIT REPORT NOVEMBER 13, 2015 DUKE ENERGY CAROLINAS, LLC INTERIM EVALUATIONS ASSOCIATED WITH RE-EVALUATED SEISMIC HAZARD IMPLEMENTING NEAR-TERM TASK FORCE RECOMMENDATION 2.1-SEISMIC FOR:

CATAWBA NUCLEAR STATION, UNITS 1 AND 2; MCGUIRE NUCLEAR STATION, UNITS 1 AND 2; AND OCONEE NUCLEAR STATION, UNITS 1, 2 AND 3 AUDIT DATE: September 15, 2015 LOCATION: NRC Offices, Rockville, MD BACKGROUND AND AUDIT BASIS:

On March 12, 2012, the U.S. Nuclear Regulatory Commission (NRC) issued a request for information pursuant to Title 10 of the Code of Federal Regulations (10 CFR) Part 50, Section 50.54(f) (hereafter referred to as the 50.54(f) letter) (Agency-wide Documents Access and Management System (ADAMS) Accession No. ML12053A340). The purpose of that request was to gather information concerning, in part, the seismic hazards at operating reactor sites to enable the NRC staff to determine whether operating licenses should be modified, suspended, or revoked.

Requested Information Item (6) in Enclosure 1 to the 50.54(f) letter requests licensees to provide an interim evaluation and actions taken or planned to address the higher seismic hazard relative to the design-basis, as appropriate, prior to completion and submission of the seismic risk evaluation. By letter dated April 8, 2013 (ADAMS Accession No. ML13102A142), the Electric Power Research Institute (EPRI) staff submitted EPRI TR 3002000704 "Seismic Evaluation guidance; Augmented Approach for the Resolution of Fukushima Near-Term Task Force Recommendation 2.1: Seismic" (hereafter referred to as the ESEP guidance). The Augmented Approach (also called the Expedited Seismic Evaluation Process (ESEP)),

proposed that licensees would use a simplified seismic margins assessment process to provide additional assurance that key components of plant equipment in one safe shutdown pathway would be able to perform certain safety functions following a beyond-design-basis seismic event. By letter dated May 7, 2013, the NRC staff endorsed this guidance.

The NRC staff is conducting technical reviews on licensees interim evaluations, to determine if the information provided meets the intent of the ESEP guidance, and if licensees responded appropriately to Requested Information Item (6) in Enclosure 1 to the 50.54(f) letter.

In December 2014, Duke Energy Carolinas, LLC (Duke, the licensee) submitted for NRC review its ESEP evaluations for Oconee, Catawba, and McGuire. The corresponding ESEP report dates, and clarification question response dates, and respective ADAMS Accession Numbers are:

2 Catawba Units 1 and 2, submitted December 31, 2014 (ML15002A261);

Clarification Question Responses submitted June 23, 2015 (ML15175A457);

McGuire Units 1 and 2, submitted December 17, 2014 (ML15005A085);

Oconee Units 1, 2 and 3, submitted December 19, 2014 (ML14364A213);

Clarification Question Responses submitted April 24, 2015 (ML15120A017).

The NRC staff issued clarification questions to gain a better understanding of the information provided in the ESEP reports. The NRC staff reviewed the information provided by Duke for the review of Catawba, McGuire, and Oconee plants, and identified a number of instances where the approach taken for these three plants differ from the typical approach taken. In order to better understand the specifics of Dukes methodologies, and to assess the applicability of the ESEP conclusions using this alternative approach, the NRC staff conducted a regulatory audit of select supporting documentation for the ESEP evaluations, including the information provided in their responses. A summary of the findings from this regulatory audit is provided in this report.

REGULATORY AUDIT SCOPE AND METHODOLOGY:

The scope of this audit is limited to the information provided and referenced in the ESEP reports and in responses to the NRC staff clarification questions, including implementation of High Confidence of Low Probability of Failure (HCLPF) calculations and fragility analysis performed for specific equipment. The purpose of this audit is to enable the NRC staff to gain a better understanding of the information used to support the licensees submittals so that the staff can make an ESEP conclusion on whether the licensees implementation meets the intent of the guidance, and if the licensee responded appropriately to Requested Information Item (6) in to the 50.54(f). Specific documents reviewed by the staff through electronic reading room access just prior to and during the audit are listed below.

DOCUMENTS PROVIDED FOR STAFF EXAMINATION:

Reports reviewed for familiarity in preparation for the audit Oconee Nuclear Station Individual Plant Examination of External Events (IPEEE) Submittal Report dated December 21, 1995, Duke Power, Seneca, SC.

Seismic Probabilistic Risk Assessment (PRA)/IPEEE Backup Calculations, Duke Energy, Seneca, SC, Rev. 0, 2011, OSC-10225.

Letter from W. R. McCollum Jr. to U. S. Nuclear Regulatory Commission, "Oconee Nuclear Station, Docket Nos.: 50-269, -270, -287; Oconee Supplemental IPEEE Submittal Report,"

dated December 15, 1997, Duke Power, Seneca, SC.

Reports used during the audit Duke Energy Report Number 030321.13.01-003, Rev. 2, Expedited Seismic Evaluation Process for Implementation of Seismic Risk Evaluations at Catawba Nuclear Station, Appendix D -

Calculations

3 Duke Energy Report Number 030319.13.02.11-001, Rev. 1, Expedited Seismic Evaluation Process for Implementation of Seismic Risk Evaluations at McGuire Nuclear Station, Appendix E - Clipped Spectra Calculations Duke Energy Calculation OSC-11188, ONS Fukushima NTTF 2.1 Seismic Vendor Support Documents for GMRS [Ground Motion Response Sprectra], Revision 2, Duke Energy, Seneca, South Carolina.

Specification for the Seismic Displacements and Response Spectra for the Turbine, Auxiliary, Reactor, and Standby Shutdown Facility Buildings, Duke Energy, Seneca, SC, Rev. 8, 2005, OSS-027B.00-00-0002.

NRC AUDIT TEAM:

Title Team Member Branch Chief (NRC/NRO/DSEA)

Diane Jackson Technical Lead (NRC/NRO/DSEA)

Nilesh Chokshi Technical Advisor (NRC/NRR)

Kamal Manoly Technical Reviewer (NRC/NRR)

Ian Tseng Technical Reviewer (NRC/NRO)

Tuan Le Technical Reviewer (NRC/NRO)

George Wang Technical Reviewer (NRC/NRO)

Richard Rivera-Lugo Technical Support Reviewer (BNL/Consultant)

Nikolaos Simos Technical Support Reviewer (BNL/Consultant)

Richard Morante Project manager (NRC/NRR/JLD)

Stephen Wyman AUDIT

SUMMARY

Applicable to Oconee, Catawba, and McGuire A number of technical issues reviewed during the audit are applicable to the ESEP evaluations of all three plants. These were addressed by Paul Baughman, ARES Corporation, on behalf of Duke Energy. The presentation is included as Attachment 1 to this audit report.

There are three primary technical issues raised by the staff regarding Duke Energys implementation of the interim evaluation guidance. Following a round of clarification questions and responses for each plant, and a teleconference with the staff on June 9, 2015, the staff determined that an audit would be the most effective means to resolve the technical issues.

The three issues relate to screening of ESEL items using the screening levels detailed in Table 2-4, Summary of Equipment and Subsystems Screening Criteria for Sesimic Margin Evaluation in EPRI-6041, Nuclear Plant Seismic Margin R-1. Duke Energy, through its consultant ARES Corporation, developed and implemented an alternate screening methodology which has not been reviewed or accepted by the staff. As this methodology is for an interim evaluation, the staff objective is not to render a technical determination on the future acceptability or applicability of Duke Energys alternate screening methodology. The staff emphasis for the audit was to develop confidence that the ESEP conclusions by the licensee would apply if the ESEP interim evaluation guidance proposed by EPRI had been traditionally followed.

4 The first issue is the comparison of the In-Structure Response Spectra (ISRS) to 1.5 times the EPRI 6041 Table 2-4 screening levels (1.2g; 1.8g) for elevations below 40 above grade.

Normally the 5% damped Review Level Ground Motion (RLGM) spectra are compared to 1.0 times the EPRI 6041 Table 2-4 screening levels (0.8g; 1.2g) for these elevations. The alternate approach taken by the licensee is compatible with methods described in EPRI 1019200, Seismic Fragility Applications Guide Update, which is referenced in EPRI Technical Report 3002000704, Seismic Evaluation Guidance: Augmented Approach for the Resolution of Fukushima Near-Term Task Force Recommendation 2.1: Seismic, for use as the criteria for application of the screening tables in EPRI 6041 at elevations beyond 40 above grade, and were judged to be conservative in this specific implementation. The licensee further stated that using 1.2g vs. RLGM at elevations within 40 of grade per EPRI 3002000794 instead of 1.8g vs.

ISRS per EPRI 1019200 would not change the screening conclusions. On that basis, the staff conceptually judges that the alternate approach to this issue is reasonable for the purposes of the interim evaluation.

The second issue is the use of raw, narrow-banded ISRS and peak clipping, whenever such spectra are available. The staffs initial expectation was that the ISRS used in screening would be design-basis broadened ISRS, not raw narrow-banded ISRS. Broadened design ISRS would not be subject to significant peak clipping, whereas clipping factors approaching the lower bound value of 0.55 are fairly typical for narrow-banded ISRS. In support of this aspect of the licensees screening methodology, the licensee indicated that peak shifting in lieu of peak broadening is permissible by EPRI 6041, and referenced EPRI 1019200 for the use of clipping factors calculated per EPRI 6041 Appendix Q. During the audit, the licensee presented an example for all three plants. The licensee stated that for these three cases, the conclusions reached by implementing the licensees methodology are equivalent to what would have been reached by implementing the EPRI evaluation guidance. The staff was satisfied with this explaination for the ESEP interim evaluation.

The third issue is the use of North-South (N-S)/ East-West (E-W) peak averaging (after clipping) to obtain the peak spectral acceleration, for comparison to the EPRI 6041 screening levels. This issue is unique to the licensees screening methodology, and the staff noted that there is no precedent for this type of averaging. The licensee stated that this method is consistent with the philosophy in EPRI 6041, in that a single ground response spectrum is specified as the review level earthquake (i.e., RLGM in ESEP evaluations). The staff noted that typically N-S and E-W ground spectra are taken to be equal for the purpose of seismic design. When using ISRS, filtered by the building structure, the peak spectral accelerations of the N-S and E-W ISRS can be significantly different. Averaging the ISRS peak accelerations can significantly reduce the numerical value that is compared to the EPRI 6041 screening levels. In response to the staffs concern, the licensee stated that the screening conclusions would be the same regardless whether the average or the higher of the two spectral peaks were used for comparison to the EPRI 6041 screening levels.

Applicable to Oconee In preparation for the audit, the staff requested the licensee to make selected reference documents available prior to the audit through the licensees ePortal. The intent was to enable the staff to focus on specific elements of the licensees screening methodology, implementation, and results during the one-day audit. One document requested for Oconee was Duke Energy Calculation OSC-11188, ONS Fukushima NTTF 2.1 Seismic Vendor Support Documents for GMRS, Revision 2. The Oconee ESEP submittal references Attachment 3 to OSC-11188 as the basis for screening all ESEL components in the Standby Shutdown Facility (SSF) and several ESEL components in the Auxiliary Building (AB) and Reactor Building (RB).

5 During initial staff review of Attachment 3, prior to the audit, the staff determined that the Oconee ESEP submittal lacked sufficient description of the Attachment 3 methodology. While the ESEP submittal identifies the SSF RLGM is equal to two times the SSF SSE, Attachment 3 presents an assessment based on the GMRS, in lieu of the SSF RLGM, and a methodology that departed from the licensees methodology as discussed above. This became one of the focus areas for the audit.

During the audit, the staff requested the licensee to provide a detailed description of the approach, and a technical justification for its validity. The licensee indicated that Attachment 3 had been prepared by its consultant, ARES Corporation, outside the scope of the ESEP. It was intended to address the large discrepancy between the newly defined Oconee GMRS and the Oconee plant design-basis SSEs (one for the AB and RB and a different one for the SSF). The consultant determined that it would be applicable to the ESEP screening evaluation, because the Attachment 3 assessment imposed a higher demand than an RLGM developed in accordance with the ESEP guidance. On this basis, screening/evaluation of all ESEL components in the SSF and selected ESEL components in the AB and RB rely on.

The licensee explained that the SSF SSE ISRS were multiplied by a factor of 2.72 for comparison to the EPRI 6041 screening levels (1.2g; 1.8g), compared to a maximum factor of 2 based on the ESEP guidance. The 2.72 factor is based on dominant horizontal mode scaling and averaging the N-S and E-W scale factors. In response to a staff question, the licensee referred to EPRI 6041, Section 4, p.4-17, as the technical basis for dominant mode scaling.

The staff reviewed EPRI 6041, Section 4, p. 4-17, and determined that it does address dominant mode scaling, but also specifies that the two response spectra (SSE vs. GMRS) should have similar shapes. This does not appear to be satisfied for Oconee. Therefore, the staff concentrated on the acceptability of the ESEP conclusions rather than on the acceptability of the methodology.

The staff requested the licensee to submit a written description of the Attachment 3 methodology, and the technical basis for the use of the Attachment 3 results in addressing the ESEP. The staff reviewed a draft summary of the Attachment 3 methodology and results through the licensees ePortaland considers it to be sufficient to make a final determination on the acceptability of the licensees conclusions.

Summary As a result of the detailed discussions during the audit, the staff gained an understanding of the licensees screening conclusions for the ESEP interim evaluation. Given the interim status of the evaluation, the staffs review is limited in scope and is not a licensing review. The validity or future applicability of the alternate methodology used by the licensee was not addressed and would need to be reviewed separately. The focus of this audit was to determine whether the licensees screening conclusions using an alternate approach were acceptable within the scope of the ESEP. Based on the information reviewed during this audit, the staff agrees with the licensees statement that the conclusions made using the licensees alternate approach are applicable to the screening of components for Catawba, McGuire, and Oconee within the scope of the ESEP, and meets the intent of the EPRI interim evaluation guidance.

6

ARES Audit Presentation

7

8

9

10

11

12

13

14

15

1 NRR-PMDAPEm Resource From:

Jackson, Diane Sent:

Thursday, December 03, 2015 2:52 PM To:

Wyman, Stephen Cc:

Tseng, Ian; Chokshi, Nilesh; Jackson, Diane; Devlin-Gill, Stephanie; Shams, Mohamed

Subject:

Duke Audit Final Audit Report.docx Attachments:

Duke Audit Final Audit Report.docx Steve -

Finally - at last, please find attached our changes and updates to the audit summary. Also, when do we expect the Oconee submittal in?

Thanks -

Diane Diane Jackson, Chief Geosciences and Geotechnical Engineering Branch 2 (RGS2)

Division of Site Safety and Environmental Analysis (DSEA), Office of New Reactors (NRO)

US Nuclear Regulatory Commission

+1 301-415-5641; office: T-7 D3; mail stop: T-7 F3 NRC - One Team - One Mission

Hearing Identifier:

NRR_PMDA Email Number:

2543 Mail Envelope Properties (bd19511a1b3a499ebe4f9b16d33b16c4)

Subject:

Duke Audit Final Audit Report.docx Sent Date:

12/3/2015 2:51:54 PM Received Date:

12/3/2015 2:51:56 PM From:

Jackson, Diane Created By:

Diane.Jackson@nrc.gov Recipients:

"Tseng, Ian" <Ian.Tseng@nrc.gov>

Tracking Status: None "Chokshi, Nilesh" <Nilesh.Chokshi@nrc.gov>

Tracking Status: None "Jackson, Diane" <Diane.Jackson@nrc.gov>

Tracking Status: None "Devlin-Gill, Stephanie" <Stephanie.Devlin-Gill@nrc.gov>

Tracking Status: None "Shams, Mohamed" <Mohamed.Shams@nrc.gov>

Tracking Status: None "Wyman, Stephen" <Stephen.Wyman@nrc.gov>

Tracking Status: None Post Office:

HQPWMSMRS07.nrc.gov Files Size Date & Time MESSAGE 467 12/3/2015 2:51:56 PM Duke Audit Final Audit Report.docx 2106208 Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received:

1 NUCLEAR REGULATORY COMMISSION AUDIT REPORT NOVEMBER 13, 2015 DUKE ENERGY CAROLINAS, LLC INTERIM EVALUATIONS ASSOCIATED WITH RE-EVALUATED SEISMIC HAZARD IMPLEMENTING NEAR-TERM TASK FORCE RECOMMENDATION 2.1-SEISMIC FOR:

CATAWBA NUCLEAR STATION, UNITS 1 AND 2; MCGUIRE NUCLEAR STATION, UNITS 1 AND 2; AND OCONEE NUCLEAR STATION, UNITS 1, 2 AND 3 AUDIT DATE: September 15, 2015 LOCATION: NRC Offices, Rockville, MD BACKGROUND AND AUDIT BASIS:

On March 12, 2012, the U.S. Nuclear Regulatory Commission (NRC) issued a request for information pursuant to Title 10 of the Code of Federal Regulations (10 CFR) Part 50, Section 50.54(f) (hereafter referred to as the 50.54(f) letter) (Agency-wide Documents Access and Management System (ADAMS) Accession No. ML12053A340). The purpose of that request was to gather information concerning, in part, the seismic hazards at operating reactor sites to enable the NRC staff to determine whether operating licenses should be modified, suspended, or revoked.

Requested Information Item (6) in Enclosure 1 to the 50.54(f) letter requests licensees to provide an interim evaluation and actions taken or planned to address the higher seismic hazard relative to the design-basis, as appropriate, prior to completion and submission of the seismic risk evaluation. By letter dated April 8, 2013 (ADAMS Accession No. ML13102A142), the Electric Power Research Institute (EPRI) staff submitted EPRI TR 3002000704 "Seismic Evaluation guidance; Augmented Approach for the Resolution of Fukushima Near-Term Task Force Recommendation 2.1: Seismic" (hereafter referred to as the ESEP guidance). The Augmented Approach (also called the Expedited Seismic Evaluation Process (ESEP)),

proposed that licensees would use a simplified seismic margins assessment process to provide additional assurance that key components of plant equipment in one safe shutdown pathway would be able to perform certain safety functions following a beyond-design-basis seismic event. By letter dated May 7, 2013, the NRC staff endorsed this guidance.

The NRC staff is conducting technical reviews on licensees interim evaluations, to determine if the information provided meets the intent of the ESEP guidance, and if licensees responded appropriately to Requested Information Item (6) in Enclosure 1 to the 50.54(f) letter.

In December 2014, Duke Energy Carolinas, LLC (Duke, the licensee) submitted for NRC review its ESEP evaluations for Oconee, Catawba, and McGuire. The corresponding ESEP report dates, and clarification question response dates, and respective ADAMS Accession Numbers are:

2 Catawba Units 1 and 2, submitted December 31, 2014 (ML15002A261);

Clarification Question Responses submitted June 23, 2015 (ML15175A457);

McGuire Units 1 and 2, submitted December 17, 2014 (ML15005A085);

Oconee Units 1, 2 and 3, submitted December 19, 2014 (ML14364A213);

Clarification Question Responses submitted April 24, 2015 (ML15120A017).

The NRC staff issued clarification questions to gain a better understanding of the information provided in the ESEP reports. The NRC staff reviewed the information provided by Duke for the review of Catawba, McGuire, and Oconee plants, and identified a number of instances where the approach taken for these three plants differ from the typical approach taken. In order to better understand the specifics of Dukes methodologies, and to assess the applicability of the ESEP conclusions using this alternative approach, the NRC staff conducted a regulatory audit of select supporting documentation for the ESEP evaluations, including the information provided in their responses. A summary of the findings from this regulatory audit is provided in this report.

REGULATORY AUDIT SCOPE AND METHODOLOGY:

The scope of this audit is limited to the information provided and referenced in the ESEP reports and in responses to the NRC staff clarification questions, including implementation of High Confidence of Low Probability of Failure (HCLPF) calculations and fragility analysis performed for specific equipment. The purpose of this audit is to enable the NRC staff to gain a better understanding of the information used to support the licensees submittals so that the staff can make an ESEP conclusion on whether the licensees implementation meets the intent of the guidance, and if the licensee responded appropriately to Requested Information Item (6) in to the 50.54(f). Specific documents reviewed by the staff through electronic reading room access just prior to and during the audit are listed below.

DOCUMENTS PROVIDED FOR STAFF EXAMINATION:

Reports reviewed for familiarity in preparation for the audit Oconee Nuclear Station Individual Plant Examination of External Events (IPEEE) Submittal Report dated December 21, 1995, Duke Power, Seneca, SC.

Seismic Probabilistic Risk Assessment (PRA)/IPEEE Backup Calculations, Duke Energy, Seneca, SC, Rev. 0, 2011, OSC-10225.

Letter from W. R. McCollum Jr. to U. S. Nuclear Regulatory Commission, "Oconee Nuclear Station, Docket Nos.: 50-269, -270, -287; Oconee Supplemental IPEEE Submittal Report,"

dated December 15, 1997, Duke Power, Seneca, SC.

Reports used during the audit Duke Energy Report Number 030321.13.01-003, Rev. 2, Expedited Seismic Evaluation Process for Implementation of Seismic Risk Evaluations at Catawba Nuclear Station, Appendix D -

Calculations

3 Duke Energy Report Number 030319.13.02.11-001, Rev. 1, Expedited Seismic Evaluation Process for Implementation of Seismic Risk Evaluations at McGuire Nuclear Station, Appendix E - Clipped Spectra Calculations Duke Energy Calculation OSC-11188, ONS Fukushima NTTF 2.1 Seismic Vendor Support Documents for GMRS [Ground Motion Response Sprectra], Revision 2, Duke Energy, Seneca, South Carolina.

Specification for the Seismic Displacements and Response Spectra for the Turbine, Auxiliary, Reactor, and Standby Shutdown Facility Buildings, Duke Energy, Seneca, SC, Rev. 8, 2005, OSS-027B.00-00-0002.

NRC AUDIT TEAM:

Title Team Member Branch Chief (NRC/NRO/DSEA)

Diane Jackson Technical Lead (NRC/NRO/DSEA)

Nilesh Chokshi Technical Advisor (NRC/NRR)

Kamal Manoly Technical Reviewer (NRC/NRR)

Ian Tseng Technical Reviewer (NRC/NRO)

Tuan Le Technical Reviewer (NRC/NRO)

George Wang Technical Reviewer (NRC/NRO)

Richard Rivera-Lugo Technical Support Reviewer (BNL/Consultant)

Nikolaos Simos Technical Support Reviewer (BNL/Consultant)

Richard Morante Project manager (NRC/NRR/JLD)

Stephen Wyman AUDIT

SUMMARY

Applicable to Oconee, Catawba, and McGuire A number of technical issues reviewed during the audit are applicable to the ESEP evaluations of all three plants. These were addressed by Paul Baughman, ARES Corporation, on behalf of Duke Energy. The presentation is included as Attachment 1 to this audit report.

There are three primary technical issues raised by the staff regarding Duke Energys implementation of the interim evaluation guidance. Following a round of clarification questions and responses for each plant, and a teleconference with the staff on June 9, 2015, the staff determined that an audit would be the most effective means to resolve the technical issues.

The three issues relate to screening of ESEL items using the screening levels detailed in Table 2-4, Summary of Equipment and Subsystems Screening Criteria for Sesimic Margin Evaluation in EPRI-6041, Nuclear Plant Seismic Margin R-1. Duke Energy, through its consultant ARES Corporation, developed and implemented an alternate screening methodology which has not been reviewed or accepted by the staff. As this methodology is for an interim evaluation, the staff objective is not to render a technical determination on the future acceptability or applicability of Duke Energys alternate screening methodology. The staff emphasis for the audit was to develop confidence that the ESEP conclusions by the licensee would apply if the ESEP interim evaluation guidance proposed by EPRI had been traditionally followed.

4 The first issue is the comparison of the In-Structure Response Spectra (ISRS) to 1.5 times the EPRI 6041 Table 2-4 screening levels (1.2g; 1.8g) for elevations below 40 above grade.

Normally the 5% damped Review Level Ground Motion (RLGM) spectra are compared to 1.0 times the EPRI 6041 Table 2-4 screening levels (0.8g; 1.2g) for these elevations. The alternate approach taken by the licensee is compatible with methods described in EPRI 1019200, Seismic Fragility Applications Guide Update, which is referenced in EPRI Technical Report 3002000704, Seismic Evaluation Guidance: Augmented Approach for the Resolution of Fukushima Near-Term Task Force Recommendation 2.1: Seismic, for use as the criteria for application of the screening tables in EPRI 6041 at elevations beyond 40 above grade, and were judged to be conservative in this specific implementation. The licensee further stated that using 1.2g vs. RLGM at elevations within 40 of grade per EPRI 3002000794 instead of 1.8g vs.

ISRS per EPRI 1019200 would not change the screening conclusions. On that basis, the staff conceptually judges that the alternate approach to this issue is reasonable for the purposes of the interim evaluation.

The second issue is the use of raw, narrow-banded ISRS and peak clipping, whenever such spectra are available. The staffs initial expectation was that the ISRS used in screening would be design-basis broadened ISRS, not raw narrow-banded ISRS. Broadened design ISRS would not be subject to significant peak clipping, whereas clipping factors approaching the lower bound value of 0.55 are fairly typical for narrow-banded ISRS. In support of this aspect of the licensees screening methodology, the licensee indicated that peak shifting in lieu of peak broadening is permissible by EPRI 6041, and referenced EPRI 1019200 for the use of clipping factors calculated per EPRI 6041 Appendix Q. During the audit, the licensee presented an example for all three plants. The licensee stated that for these three cases, the conclusions reached by implementing the licensees methodology are equivalent to what would have been reached by implementing the EPRI evaluation guidance. The staff was satisfied with this explaination for the ESEP interim evaluation.

The third issue is the use of North-South (N-S)/ East-West (E-W) peak averaging (after clipping) to obtain the peak spectral acceleration, for comparison to the EPRI 6041 screening levels. This issue is unique to the licensees screening methodology, and the staff noted that there is no precedent for this type of averaging. The licensee stated that this method is consistent with the philosophy in EPRI 6041, in that a single ground response spectrum is specified as the review level earthquake (i.e., RLGM in ESEP evaluations). The staff noted that typically N-S and E-W ground spectra are taken to be equal for the purpose of seismic design. When using ISRS, filtered by the building structure, the peak spectral accelerations of the N-S and E-W ISRS can be significantly different. Averaging the ISRS peak accelerations can significantly reduce the numerical value that is compared to the EPRI 6041 screening levels. In response to the staffs concern, the licensee stated that the screening conclusions would be the same regardless whether the average or the higher of the two spectral peaks were used for comparison to the EPRI 6041 screening levels.

Applicable to Oconee In preparation for the audit, the staff requested the licensee to make selected reference documents available prior to the audit through the licensees ePortal. The intent was to enable the staff to focus on specific elements of the licensees screening methodology, implementation, and results during the one-day audit. One document requested for Oconee was Duke Energy Calculation OSC-11188, ONS Fukushima NTTF 2.1 Seismic Vendor Support Documents for GMRS, Revision 2. The Oconee ESEP submittal references Attachment 3 to OSC-11188 as the basis for screening all ESEL components in the Standby Shutdown Facility (SSF) and several ESEL components in the Auxiliary Building (AB) and Reactor Building (RB).

5 During initial staff review of Attachment 3, prior to the audit, the staff determined that the Oconee ESEP submittal lacked sufficient description of the Attachment 3 methodology. While the ESEP submittal identifies the SSF RLGM is equal to two times the SSF SSE, Attachment 3 presents an assessment based on the GMRS, in lieu of the SSF RLGM, and a methodology that departed from the licensees methodology as discussed above. This became one of the focus areas for the audit.

During the audit, the staff requested the licensee to provide a detailed description of the approach, and a technical justification for its validity. The licensee indicated that Attachment 3 had been prepared by its consultant, ARES Corporation, outside the scope of the ESEP. It was intended to address the large discrepancy between the newly defined Oconee GMRS and the Oconee plant design-basis SSEs (one for the AB and RB and a different one for the SSF). The consultant determined that it would be applicable to the ESEP screening evaluation, because the Attachment 3 assessment imposed a higher demand than an RLGM developed in accordance with the ESEP guidance. On this basis, screening/evaluation of all ESEL components in the SSF and selected ESEL components in the AB and RB rely on.

The licensee explained that the SSF SSE ISRS were multiplied by a factor of 2.72 for comparison to the EPRI 6041 screening levels (1.2g; 1.8g), compared to a maximum factor of 2 based on the ESEP guidance. The 2.72 factor is based on dominant horizontal mode scaling and averaging the N-S and E-W scale factors. In response to a staff question, the licensee referred to EPRI 6041, Section 4, p.4-17, as the technical basis for dominant mode scaling.

The staff reviewed EPRI 6041, Section 4, p. 4-17, and determined that it does address dominant mode scaling, but also specifies that the two response spectra (SSE vs. GMRS) should have similar shapes. This does not appear to be satisfied for Oconee. Therefore, the staff concentrated on the acceptability of the ESEP conclusions rather than on the acceptability of the methodology.

The staff requested the licensee to submit a written description of the Attachment 3 methodology, and the technical basis for the use of the Attachment 3 results in addressing the ESEP. The staff reviewed a draft summary of the Attachment 3 methodology and results through the licensees ePortaland considers it to be sufficient to make a final determination on the acceptability of the licensees conclusions.

Summary As a result of the detailed discussions during the audit, the staff gained an understanding of the licensees screening conclusions for the ESEP interim evaluation. Given the interim status of the evaluation, the staffs review is limited in scope and is not a licensing review. The validity or future applicability of the alternate methodology used by the licensee was not addressed and would need to be reviewed separately. The focus of this audit was to determine whether the licensees screening conclusions using an alternate approach were acceptable within the scope of the ESEP. Based on the information reviewed during this audit, the staff agrees with the licensees statement that the conclusions made using the licensees alternate approach are applicable to the screening of components for Catawba, McGuire, and Oconee within the scope of the ESEP, and meets the intent of the EPRI interim evaluation guidance.

6

ARES Audit Presentation

7

8

9

10

11

12

13

14

15