1 NRR-PMDAPEm Resource From:
Pickett, Douglas Sent:
Monday, December 07, 2015 2:33 PM To:
Prussman, Stephen G (SPrussm@entergy.com)
Cc:
Jenkins, Joel; McHale, John
Subject:
Acceptance Review for Indian Point 2 Relief Request ISI-RR-01 Mr. Prussman:
By letter dated October 29, 2015, Entergy Nuclear Operations, Inc. submitted relief request IP2-ISI-RR-01 for Indian Point Nuclear Generating Unit No. 2 (CAC No. MF7082). The relief request would provide an alternative to the ASME Section XI requirements for the upper pressurizer welds for the fifth 10-year inservice inspection interval.
The purpose of this e-mail is to provide the results of the Nuclear Regulatory Commission (NRC) staffs acceptance review of the relief request. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review. The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.
The NRC staff has reviewed your application and concludes that it provides technical information in sufficient detail to enable the staff to complete its detailed technical review and make an independent assessment regarding the acceptability of the proposed request in terms of regulatory requirements and the protection of public health and safety and the environment. Given the lesser scope and depth of the acceptance review as compared to the detailed technical review, there may be instances in which issues that impact the staffs ability to complete the detailed technical review are identified despite completion of an adequate acceptance review.
If additional information is needed, you will be advised by separate correspondence.
Please contact me if you have any questions. A copy of this email will be made publicly available in ADAMS.
Doug Douglas V. Pickett, Senior Project Manager Indian Point Nuclear Generating Unit Nos. 2 & 3 James A FitzPatrick Nuclear Power Plant Douglas.Pickett@nrc.gov 301-415-1364
Hearing Identifier:
NRR_PMDA Email Number:
2535 Mail Envelope Properties (Douglas.Pickett@nrc.gov20151207143200)
Subject:
Acceptance Review for Indian Point 2 Relief Request ISI-RR-01 Sent Date:
12/7/2015 2:32:33 PM Received Date:
12/7/2015 2:32:00 PM From:
Pickett, Douglas Created By:
Douglas.Pickett@nrc.gov Recipients:
"Jenkins, Joel" <Joel.Jenkins@nrc.gov>
Tracking Status: None "McHale, John" <John.McHale@nrc.gov>
Tracking Status: None "Prussman, Stephen G (SPrussm@entergy.com)" <SPrussm@entergy.com>
Tracking Status: None Post Office:
Files Size Date & Time MESSAGE 1986 12/7/2015 2:32:00 PM Options Priority:
Standard Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
Recipients Received:
1 NRR-PMDAPEm Resource From:
Pickett, Douglas Sent:
Monday, December 07, 2015 2:33 PM To:
Prussman, Stephen G (SPrussm@entergy.com)
Cc:
Jenkins, Joel; McHale, John
Subject:
Acceptance Review for Indian Point 2 Relief Request ISI-RR-01 Mr. Prussman:
By letter dated October 29, 2015, Entergy Nuclear Operations, Inc. submitted relief request IP2-ISI-RR-01 for Indian Point Nuclear Generating Unit No. 2 (CAC No. MF7082). The relief request would provide an alternative to the ASME Section XI requirements for the upper pressurizer welds for the fifth 10-year inservice inspection interval.
The purpose of this e-mail is to provide the results of the Nuclear Regulatory Commission (NRC) staffs acceptance review of the relief request. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review. The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.
The NRC staff has reviewed your application and concludes that it provides technical information in sufficient detail to enable the staff to complete its detailed technical review and make an independent assessment regarding the acceptability of the proposed request in terms of regulatory requirements and the protection of public health and safety and the environment. Given the lesser scope and depth of the acceptance review as compared to the detailed technical review, there may be instances in which issues that impact the staffs ability to complete the detailed technical review are identified despite completion of an adequate acceptance review.
If additional information is needed, you will be advised by separate correspondence.
Please contact me if you have any questions. A copy of this email will be made publicly available in ADAMS.
Doug Douglas V. Pickett, Senior Project Manager Indian Point Nuclear Generating Unit Nos. 2 & 3 James A FitzPatrick Nuclear Power Plant Douglas.Pickett@nrc.gov 301-415-1364
Hearing Identifier:
NRR_PMDA Email Number:
2535 Mail Envelope Properties (Douglas.Pickett@nrc.gov20151207143200)
Subject:
Acceptance Review for Indian Point 2 Relief Request ISI-RR-01 Sent Date:
12/7/2015 2:32:33 PM Received Date:
12/7/2015 2:32:00 PM From:
Pickett, Douglas Created By:
Douglas.Pickett@nrc.gov Recipients:
"Jenkins, Joel" <Joel.Jenkins@nrc.gov>
Tracking Status: None "McHale, John" <John.McHale@nrc.gov>
Tracking Status: None "Prussman, Stephen G (SPrussm@entergy.com)" <SPrussm@entergy.com>
Tracking Status: None Post Office:
Files Size Date & Time MESSAGE 1986 12/7/2015 2:32:00 PM Options Priority:
Standard Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
Recipients Received: