ML15267A586
Text
1 2
3 4
5 6
7 8
9 10 1 1 12 13 14 15 16 17 18 19 G-191236 A
B
-L!'GE~D, A
a.A.
ourSID£ Alit suppLy Alit eXWAlJ&T AI R.
CFU CU⁣ FE-ET PElt UlhlUTE-O.D.
6tl.AVIT'i OAUPf:R.
IANJLJAL OPE-RATED OAMpeR..
B
--,'-~
A\\R opelt~Teo DAMp6l V. D.
VO'-UME:
DAMPER c
c G
J E
K D
F H
L Ci-I e, 11.4S
(;-'91 t4."
Ci--I.,tt",
G-I' It..,,
G-,t),t49 (jo-'CFillSO
'i'-.,4,JI(5.
1!to £.4~"
~H a.. :!t t/
. DATE REFERENCE DRNN\\NG5 HVAC -
RADWASrfo
&LOG.
HV.4C -
Eeu pJ..4E~T Ilt.l.,f.4 - I
.-IVA C -
- QVI P~=l!T RL4.
O~ - -!
HVAC -
!QUIPUEUT RiA 5H-'
f.fVAC -
Fl!ACTO~
l!>>LOG-PL.A~5 - 5t-4.. f
"'VAC -
~eA:TO~
e>L.O<i.- pLA~S -
~J.4-t HVAC -
Rf:ACTOIl P>LD6-pLAtJ5 - 5U- ~
p", 'D -
RADW~~n. SV"T£M NOTES PIPING 2 INCHES AND SMALLER TO BE FIELD RUN.
FIELD TO LOCATE, DETER~I~E SIZE AND SET ALL PIPE SLEEVES IN CONCRETE FLOORS BEfORE CON-CRETE IS PLACED.
SEE STRUCTURAL DRAVtNGS FOR TYPICAL DETAILS Of PIPE SLEEVES AND fOR fLOOR OPENINGS REQUJRING SPECllL fLOOR fRAMING.
OPENINGS 8 INCH I~ DIAMETER AND OVER FOR SHOP FABRICATED PIPING, IN GRATING AND CHECKERED PlAiE FLOORS, SHALL BE PROVIDED IN THE SHOP.
ALL OTHER OPENINGS ARE TO BE PROVIDED IN THE FIELD.
ALL OPENINGS, EXCEPT THOSE FOR STRESS ANA-LYZED PIPE LINES,. SHALL CLEAR PIPE INSULA-TION BY A MINIMUM OF I INCH BEYOND E~TREME PIPE MOVEMENT.
ALL HEATING, VENTILAT.NG AND AIR CONDITIONING EQUIPMENT FURNISHED SHALL SUIT THE ARRANGEMENTS, OPENINGS, BASES, SUPPORTS6 ETC.
PROVIDED FOR THE EQUIPMENT AS INDICATE ON THESE DRAWINGS.
ANY CHANGES ON THESE DRAWINGS RESULTING fROM EQUIPMENT DEVIATIONS SHALL BE THE RESPONSIBILITY OF THE HEATING AND VENTILATING CONTRACTOR.
ALL PIPING A,~O INSTRUMENTATION I'> NON*
~A,;'::C=T (
CLASS.
j
'600 Co' ""
C,Otool-:TItOL R.oo~
- II 5' 0 CFfo\\
PIP&
TUNNEL (APJOV£)
t 1150CFM j
\\..
/
AAD-41 CO'-1DEN':>>ATE PMAc:.e:
TA~~
IOOOc.J'1
'-.lOTE; TO MAIUTAIN
~LIGJ..4T
~ATtW PR6SSIJCE HJ CUD WA~Tr; BL.DIO SOD C:FM, ADPlTlOJJA\\".
ISX.HAU~T
'~TA\\(elJ FI.O'l\\.
1041~
AItE.taa T~4~
.4P 50PpLIED tUTo Eb\\.DG.A
\\00 I
I!.9~O Cr:M _J t~P1 I'DS. 100C
-~ G.{)
I
~,~ COMPRl!SSO" I
c.. zo*,o~
"00 C.FM I (')0
~
I
-1
'000 C.F'M,t
\\C.F~
~....-+-
I I AAD-40 '1
~.\\">.
IOOOC.FM~
Ot-3 I
900 C.FIl'\\~.....:-..
I
~
I I I
sO I~ _L-.J~Mt IC.FI'1 r I -
- ---l AAD-39
.~
~
~
~......
~
I G.t>.
RWB-HVAC-EXAUST I
I
~ ~
EXH N
~ ~ ~
I I
lsoc.r:t'\\~,
RWE~IA4( :\\'
AB~~~.~:~~~~ I" _l.....-.I42~O'FI1 k~
,-J'--'"
,f!)RWB:.HVAC-SUPPL0 CoIOO CFM
~\\
\\
~
I I l~
AAD-38 'i..
Wr2E~~l-H=~T COtL - P-.WSC-2 (EACHJ'A \\
11.0QC~..
c:. D.
"I
---;--'I~r-.I.
t I
r peEH EA.Teo IL - '"W5 C-,
D.
l~:.\\
\\.= \\:
15~,
)
n.n.
w8-(,
/
I rFROM RADWASTE I
f7//
/
rag]
FIXED LOUVER
- DB 4
~~....~ ~ i.f~~l~~~~l~::~~B-.3})
t
((DUCT-RWB-l1 ~- i -, ~.
- ' "'-l~;OO 'F"I
\\
rnn
~
(
000 c'Fr1.-
- 0& I)~
UP TMROS14'~
- i I
\\
I!
~2J2~pO c"F'fll\\
J05~&I='K hlt""""""
o I"
JI~'q,o 'F'~
./,
'\\..
I I I
,osc c...~/
~SUPPLY FAN" Rwc;.~A,'S "'FrLTER L~oocr:1lo\\
I UP V.D.
15rSO.CFM,EAQ\\}
RW-F-3A[)
MD-37 ! I r~O 1.'r----------1-J~--:_.-----r....
SOOCJ"M f-.-
I.~ -t.. 1. ~ I 2100 c..FM AAD-26 I &A~R.~
.L T
....V.I>.
.~
I Bl\\l\\~~ AREA lesc L"~7~9 f I
L~I~
~t-f\\Et>LAC.~A.BLe: II LsG,700 C.r:'M CFM.~
AAD-25 I
ARS.-A FI LTtR.
I D
AAD-36 I jIta--------,
250Cr:'M, 2S0(F'MI l t J
(000 CF'M J-SOOC.~M~
r" I
'J.e>.
I I
PRECOA.1 TAN\\(. ~ PUMP I
vt>
.I
, 40ccrM I
1=", LTER A'D l'~'3K~ ~ PUMP
- -?~i;;--
450 CFM I
C~EfW\\. AQD. TAI-JK..
I r-I ISOOCFM
- r- -
-V-.D'r~1 I
I 10'
~
~
AAD'"=-24 PUMP R.ootoJ\\
AAD-34 AAD-35 1 ~~~~ f- -I I
I
__L G.Df i*
D I It 250 CFM 1
I I '= -r
!.. ~_t_OO_C.F'_M
--J In--r-"'~ 4CONN.T:T:K_L.t
)
1.
I AAq,-32M
---I--~~~~t:=~=:--t La--'V-150c:.~t'\\
A
--.T6 a-.......:...4 SOO CFM rw
~
MPL,E V.D.,.;,
]
V.D.
R. OR.
AAD-33 HOOD........
I}:
~ ~
FILTER G.D..
HOLD\\~e:.f IpUMP ARE-A
....f...-_1
- '--_*-t~cooo CFM I
150C.FI'I\\ __I.'
,.(..".0.
(gOO CFM
~v.o.
I t--
I~'I*r~l'I--\\r-
~.~
I r
1.J
., \\,
"~<:,r,,,\\
,.,~ 150<f:M
\\"oC:~h AAD-3'1 IUlTftUMl"'~T WAS1E AAD-30 AAD-29 G.D.
~
I F'LTER GO" G.D.
r--. FUE\\. Poo'-
I I
OOM t
-='H**T£~
I
\\SOf:.f'",--L'r-lc
.D*~I~~~""'SOCFl'\\ I I,
I
- 'I- ~~ -I.JI ~,
- a.:.900CfM DN l.J
- 1M.U -=..r~,~
-.-..J'r-- ISOcr""
fSO~"
I I~
WA-S1E-FOE~ pOO\\-
OEM'~.
FIL.lE.R.
I A
'SOC"~ -I..-rlf ".O*::'dLf....--.. lSOcF'fl"\\
I.... 'If
- ..1ojoo1l,;,rII"...+ " I
'1[
"f I
1--......,----4 AAD-2!../
'LAAD-28 I) 3500 eF"'"
G.D.
G.D.
I 1/
ON F'L. El. "l.St~~
"--------------------____;;_.-+----tJ--+-IIC---------------.--.~-------
4500 CFfo'\\.../ I
. ~
UP:
I
!SOO c.F'~......
r-1(050 I
~" CFM PUMP AREA~'"
I
-+---=tIF-------t I
I I
I I
I
~
I I
~-~
I I
V.D.
V.D.
-f"'-f-- ----ri:-4+------.J I
I I
I 300 wooCo""
It00,~~
c:,."" c:.w>s P~UE I I
It
~'P£ijT ~~,tJ 1'-
I pu""p~
WAS.TE s.LUOiJE I I
5I'r:NT U~'~"AN(
F\\.)1W\\P I
I L _
1..c:,~-+tJ TO CONDEN5ATE PI4A5E., TAt-JK5 VE.NT C.ONN,s,.
D G
E H
J K
F L
TO FILTER ~LU06E TANK VENT. CONN.
CW50 CF'1
.lJ t>oo~
"'OUVE~
f-I--
M M
RADWASTE.
BUILDltJq 9
REVISED PER CU 2002-034 12 04 2-I~ - 0 4-
/2 - /0 -'J (.
?
NL ill)::>
Jdi.:c 8
REVISED PER ER 2000-1056 9-7-00 9-11-009-14-00 SJM ADP MJS ENTERGY NUCLEAR VERMONT YANKEE VERNON, VERMONT N
REV*--
Entergy Nuclear Nortbcut DESCRIPTION BY CHKD.
APPD.
N THIS IS AN FSAR DRAWING DRAWING TITLE DRAWING NO.
HVAC FLOW DIAGRAM RADWASTE BUILDING G-191236 1
2 3
4 5
6 7
8 9
10 11 12 13 14 15 16 17 18 19