July 19, 1989 Docket Nos:
50-269 50-270 50-287 Mr. H. B. Tucker, Vice President Nuclear Production Department Duke Power Company 422 South Church Street Charlotte, North Carolina 28242
Dear Mr. Tucker:
SUBJECT:
SAFETY EVALUATION REPORT ON DPC-NE-2003, "CORE THERMAL-HYDRAULIC METHODOLOGY USING VIPRE-01" (TACS 69377/69378/69379)
The staff and its consultant, International Technical Services, have reviewed your Topical Report DPC-NE-2003, "Core Thermal-Hydraulic Methodology Using VIPRE-01" submitted for application to the Oconee Nuclear Station, Units 1, 2 and 3. We have found the topical report to be acceptable for referencing in the core thermal-hydraulic analyses for the Oconee units with the following limitations:
(1)
The acceptable DNBR limit is 1.18.
Acceptance of a DNBR limit less than 1.18 will require analysis of a broader CHF data base and detailed staff review.
(2)
The studies provided in the topical report were performed with the fuel assembly desigh currently used in the Oconee units.
Although the approach is acceptable for future fuel assembly designs, you should ensure that the selected correlations are used within their applicability ranges.
A copy of our Safety Evaluation Report is enclosed. This completes our action under TAC Nos. 69377, 69378 and 69379.
Sincerely, Original signed by:
Leonard A. Wiens, Project Manager Project Directorate 11-3 Division of Reactor Projects -
I/II Office of Nuclear Reactor Regulation
Enclosure:
As stated a
cc w/encl:
See next page on oo DISTRIBUTION:
ow, Docket File D. Matthews B. Grimes 9/A/2 NRC & Local PDRs M. Rood ACRS (10)
P 315 PD 11-3 Reading L. Wiens W. Hodges.
8/E/23 S. Varga 14/E/4 OGC G. Lainas 14/H/25 E. Jordan MNBB-3302
[SER LTR OCONEE 69377/78/79]
PD II-PD 11-3 3
MRood LWiens:sa tthews S/.1/89
-7
/1-1/89
/W/89
cc:
Mr. A. V. Carr, Esq.
Mr. Paul Guill Duke Power Company Duke Power Company P. 0. Box 33189 Post Office Box 33189 422 South Church Street 422 South Church Street Charlotte, North Carolina 28242 Charlotte, North Carolina 28242 J. Michael McGarry, III, Esq.
Bishop, Cook, Purcell & Reynolds Mr. Alan R. Herdt, Chief 1400 L Street, N.W.
Project Branch #3 Washington, D.C. 20005 U.S. Nuclear Regulatory Commission 101 Marietta Street, NW, Suite 2900 Mr. Robert B. Borsum Atlanta, Georgia 30323 Babcock & Wilcox Nuclear Power Division Ms. Karen E. Long Suite 525 Assistant Attorney General 1700 Rockville Pike N. C. Department of Justice Rockville, Maryland 20852 P.O. Box 629 Raleigh, North Carolina 27602 Manager, LIS NUS Corporation 2536 Countryside Boulevard Clearwater, Florida 34623-1693 Senior Resident Inspector U.S. Nuclear Regulatory Commission Route 2, Box 610 Seneca, South Carolina 29678 Regional Administrator, Region II U.S. Nuclear Regulatory Commission 101 Marietta Street, N.W., Suite 2900 Atlanta, Georgia 30323 Mr. Heyward G. Shealy, Chief Bureau of Radiological Health South Carolina Department of Health and Environmental Control 2600 Bull Street Columbia, South Carolina 29201 Office of Intergovernmental Relations 116 West Jones Street Raleigh, North Carolina 27603 Honorable James M. Phinney County Supervisor uf Oconee County Walhalla, South Carolina 29621