August 29, 1986 Dockets Nos. 50-269, 50-270 and 50-287 Mr. Hal B. Tucker Vice President -

Nuclear Production Duke Power Company P. 0. Box 33189 422 South Church Street Charlotte, North Carolina 28242

Dear Mr. Tucker:

SUBJECT:

HYDROGEN RECOMBINER SYSTEM-REQUEST FOR ADDITIONAL INFORMATION REGARDING:

Oconee Nuclear Station, Units 1, 2 and 3 By letter dated February 12, 1986, you proposed an amendment to the Technical Specifications on the operation and maintenance of the containment hydrogen recombiner system. This system will be used as the primary method to maintain the post-accident containment atmosphere hydrogen concentration below the control limit.

To complete our review, we need the additional information identified in the enclosure. We request that you respond to this request for additional information within thirty days of receipt of this letter. The reporting and/or recordkeeping requirements contained in this letter affect fewer than ten respondents; therefore, OMB clearance is not required under P.L.96-511.

Sincerely, 8609100160 860829 PDR ADOCK 05000269 John F. Stolz, Director p

PDR PWR Project Directorate #6 Division of PWR Licensing-B

Enclosure:

As stated cc w/enclosure:

See next page DISTRIBUTION ACRS-10 GEdison D>

BGrimes NRC P JPartlow L PDR HPastis PBD-6 Rdg RIngram FMiraglia Gray File OGC-MNBB 9604 NThompson EJordan SWest PB PBd-6a1f PBd-6 PBD-6 I tis;jak S

CMcCracken GEdison JStolz 8/

86 8/l,/86 8/ k/96 8/ /86 8/ /86

Mr. H. B. Tucker Oconee Nuclear Station Duke Power Company Units Nos. 1, 2 and 3 cc:

Mr. William L. Porter Mr. Paul F. Guill Duke Power Company Duke Power Company P. 0. Box 33189 Post Office Pox 33189 422 South Church Street 422 South Church Street Charlotte, North Carolina 28242 Charlotte, North Carolina 2F242 J. Michael McGarry, III, Esq.

Bishop, Liberman, Cook, Purcell & Reynolds 1200 Seventeenth Street, N.W.

Washington, D.C. 20036 Mr. Robert B. Borsum Babcock & Wilcox Nuclear Power Generation Division Suite 220, 7910 Woodmont Avenue Bethesda, Maryland 20814 Manager, LIS NUS Corporation 2536 Countryside Boulevard Clearwater, Florida 33515 Senior Resident Inspector U.S. Nuclear Regulatory Commission Route 2, Box 610 Seneca, South Carolina 29678 Regional Administrator U.S. Nuclear Regulatory Commission 101 Marietta Street, N.W.

Suite 3100 Atlanta, Georgia 30303 Mr. Heyward G. Shealy, Chief Bureau of Radiological Health South Carolina Department of Health and Environmental Control 2600 Bull Street Columbia, South Carolina 29201 Office of Intergovernmental Relations 116 West Jones Street Raleigh, North Carolina 27603 Honorable James M. Phinney County Supervisor of Oconee County Walhalla, South Carolina 29621

ENCLOSURE REQUEST FOR ADDITIONAL INFORMATION OCONEE NUCLEAR STATION UNITS 1, 2 AND 3 HYDROGEN CONTROL SYSTEM

1. Provide the following information on the external hydrogen recombiner used at the Oconee plant:
a. Identify the type of recombiner. Reference to the manufacturer's literature could be made if the recombiner is of a standard design.

If, however, it is a custom made unit, detailed design information, including design drawings, should be provided.

b. Describe the installation of the recombiner in the Oconee plant.

The description given in the Final Safety Analysis Report (FSAR) does not give sufficient information to enable us to review the operation of the system. Provide a detailed installation drawing which clearly shows how the recombiner interfaces with existing plant systems.

2. Identify the alternate power sources to be used for operating the recombiner system during a loss of offsite power.