ML15264A272

From kanterella
Jump to navigation Jump to search
Forwards SER on Util 831230 & 841024 Responses to Generic Ltr 83-28, Required Actions Based on Generic Implications of Salem ATWS Events, Including Item 4.3.Response Acceptable.Addl Info Required within 30 Days of Ltr Receipt
ML15264A272
Person / Time
Site: Oconee  
Issue date: 02/11/1985
From: Stolz J
Office of Nuclear Reactor Regulation
To: Tucker H
DUKE POWER CO.
Shared Package
ML15264A273 List:
References
GL-83-28, NUDOCS 8502250935
Download: ML15264A272 (2)


Text

FEB 1985 Dockets Nos. 50-269, 50-270 and 50-287 Gray File NRC PDR HNicolaras L PDR RIngram Mr. H. B. Tucker DEisenhut EBlackwood Vice President - Nuclear Production OELD HOrnstein Duke Power Company EJordan

L01shan, P. 0. Box 33189 PMcKee

]

) iN tri 422 South Church Street JPartlow Charlotte, North Carolina 28242 ACRS-10

Dear Mr. Tucker:

SUBJECT:

SHUNT TRIP MODIFICATIONS -

ITEM 4.3 OF GENERIC LETTER 83-28 Re:

Oconee Nuclear Station, Units 1, 2 and 3 By letters dated December 30, 1983 and October 24, 1984, you responded to Generic Letter 83-28, "Required Actions Based on Generic Implications of Salem ATWS Events," including Item 4.3 on reactor trip systems reliability-automatic actuation of the shunt trip attachment. We have reviewed your proposed design for automatic actuation of the reactor trip breaker shunt trip attachments and find it acceptable.

As noted in the enclosed Safety Evaluation, we request that:

1. You confirm that the shunt trip attachment has been seismically qualified when the ongoing investigation of this matter has been concluded; and
2. You submit changes to the Technical Specifications to explicitly note that the testing independently confirms the operability of the shunt and undervoltage trip attachments consistent with your test procedure.

We request that you provide the above information within 30 days of receipt of this letter. If the information is not available at this time, then we request that you provide a schedule for submitting this information and a justification for those dates. This request for information affects fewer than ten respondents; therefore, OMB clearance is not required under P.L.96-511.

Sincerely, John F. Stolz, Chief Operating Reactors Branch #4 Division of Licensing

Enclosure:

Safety Evaluation 8502250935 850211 cc w/enclosure:

PDR ADOCK 05000269 See next page P

PDR at4:DL Dlaras;cf JSt 1/30/85 1/

Duke Power Company cc w/enclosure(s):

Mr. William L. Porter Duke Power Company P. 0. Box 33189 422 South Church Street Office of Intergovernmental Relations Charlotte, North Carolina 28242 116 West Jones Street Ral-eiqh, North Carolina 27603 Honorable James M. Phinney County Supervisor of Oconee County Walhalla, South Carolina 29621 Mr. James P. O'Reilly, Regional Administrator U. S. Nuclear Regulatory Commission, Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Heyward G. Shealy, Chief Bureau of Radiological Health South Carolina Department of Health and Environmental Control Regional Radiation Representative 2600 Bull Street EPA Region IV Columbia, South Carolina 29201 345 Courtland Street, N.E.

Atlanta, Georgia 30308 Mr. J. C. Bryant Senior Resident Inspector U.S. Nuclear Regulatory Commission Route 2, Box 610 Seneca, South Carolina 29678 Mr. Robert B. Borsum Babcock & Wilcox Nuclear Power Generation Division Suite 220, 7910 Woodmont Avenue Bethesda, Maryland Z0814 Manager, LIS NUS Corporation 2536 Countryside Boulevard Clearwater, Florida 33515 J. Michael McGarry., III, Esq.

Bishop, Liberman, Cook, Purcell & Reynolds 1200 17th Street, N.W.

Washington, 0. C. 20036