UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 January 20, 1999 LICENSEE:

Duke Energy Corporation (Duke)

FACILITY:

Oconee Nuclear Station, Units 1, 2, and 3

SUBJECT:

SUMMARY

OF JANUARY 14,1999, PHONE CALL BETWEEN THE U.S.

NUCLEAR REGULATORY COMMISSION (NRC) STAFF AND DUKE REPRESENTATIVES TO DISCUSS THE OCONEE LICENSE RENEWAL APPLICATION On January 14, 1999, representatives of Duke had a phone call with the NRC staff in Rockville, Maryland, to discuss the Oconee license renewal application. The purpose of the phone call was to discuss requests for additional information (RAls) 3.4.5-4, 3.4.5-6, and 4.18-4 and how they relate to Babcock and Wilcox (B&W) Topical Report 2251 "Demonstration of the Management of Aging Effects for the Reactor Vessel." The Duke participants were Robert Gill and William Brady. The staff participants were Barry Elliot and Joe Sebrosky.

Duke had requested the call because the issues identified in the RAls above related to Open Items numbers 2 and 4 in the staff's safety evaluation of September 18, 1998, for B&W Topical Report 2251. Duke noted that the B&W Owner's Group had provided responses to these open items and questioned if the Owner's Group responses would address the issue. In order to address Duke's concerns, the staff provided its feedback regarding the Owner's Group responses for the two open items in question as follows.

Concerning Open Item No. 2: The B&W Owner's Group responded that the flow stabilizers will remain within the scope of license renewal but are not subject to aging management review because failure of the flow stabilizers has not occurred at any of the B&W operating plants. The staff agrees with the B&W Owner's Group except that if an applicant has installed flow stabilizers using Alloy 600 and/or Alloy 82/182 weld material, the applicant must include the flow stabilizers in its Alloy 600 aging managing program. Alloy 600 and Alloy 82/182 weld materials are susceptible to cracking in primary water environments.

Concerning Open Item No. 4: The B&W Owner's Group believes that Topical Report B&W-2274 satisfies the requirements of 10 CFR 54.21(c) for an evaluation of time-limited aging analyses of underclad cracking in B&W reactor pressure vessel forgings. The staff agrees that the topical report satisfies the requirements of 10 CFR 54.21(c) and does not believe additional examination of the underclad cracks is necessary because the predicted flaw size is below the value specified in IWB-3510-1 of Section XI of the ASME Code and the predicted amount of flaw growth is conservative.

9901250258 990120 PDR ADOCK 05000269 P

'PDR January 20, 1999 The staff explained that the RAls for the Oconee license renewal application were developed prior to the staff being able to evaluate the B&W Owner's Group responses regarding B&W Topical Report 2251. Duke agreed to consider the above feedback in responding to RAls 3.4.5-4, 3.4.5-6, and 4.18-4.

original signed by:

Joseph M. Sebrosky, Project Manager License Renewal Project Directorate Division of Reactor Program Management Office of Nuclear Reactor Regulation Docket Nos. 50-269, 50-270, and 50-287 cc w/encls: See next page DISTRIBUTION:

See next page DOCUMENT NAME:G:\\SEBROSKY\\1 14PHN.WPD OFFICE LA PM:PDLRDRPM EMCB/DE D:PDLR NAME IBerry JSebrosk BElliot 6 ClGrimes DATE

/04/99 1

/ 19

/10/99

_/w/99 OFFICIAL RECORD COPY

Oconee Nuclear Station (License Renewal)

Mr. J. E. Burchfield cc:

Compliance Manager Duke Energy Corporation Ms. Lisa F. Vaughn Oconee Nuclear Site Duke Energy Corporation P. 0. Box 1439 422 South Church Street Seneca, South Carolina 29679 Mail Stop PB-05E Charlotte, North Carolina 28201-1006 Ms. Karen E. Long Assistant Attorney General J. Michael McGarry, Ill, Esquire North Carolina Department of Justice Anne W. Cottingham, Esquire P. 0. Box 629 Winston and Strawn Raleigh, North Carolina 27602 1400 L Street, NW.

Washington, DC 20005 L. A. Keller Manager - Nuclear Regulatory Licensing Mr. Rick N. Edwards Duke Energy Corporation Framatome Technologies 526 South Church Street Suite 525 Charlotte, North Carolina 28201-1006 1700 Rockville Pike Rockville, Maryland 20852-1631 Mr. Richard M. Fry, Director Division of Radiation Protection Manager, LIS North Carolina Department of NUS Corporation Environment, Health, and 2650 McCormick Drive, 3rd Floor Natural Resources Clearwater, Florida 34619-1035 3825 Barrett Drive Raleigh, North Carolina 27609-7721 Senior Resident Inspector U. S. Nuclear Regulatory Commission Gregory D. Robison 7812B Rochester Highway Duke Energy Corporation Seneca, South Carolina 29672 Mail Stop EC-12R P. 0. Box 1006 Regional Administrator, Region II Charlotte, North Carolina 28201-1006 U. S. Nuclear Regulatory Commission Atlanta Federal Center Robert L. Gill, Jr.

61 Forsyth Street, SW, Suite 23T85 Duke Energy. Corporation Atlanta, Georgia 30303 Mail Stop EC-12R P. 0. Box 1006 Virgil R. Autry, Director Charlotte, North Carolina 28201-1006 Division of Radioactive Waste Management RLGILL@DUKE-ENERGY.COM Bureau of Land and Waste Management Department of Health and Douglas J. Walters Environmental Control Nuclear Energy Institute 2600 Bull Street 1776 I Street, NW Columbia, South Carolina 29201-1708 Suite 400 Washington, DC 20006-3708 County Supervisor of Oconee County DJW@NEI.ORG Walhalla, South Carolina 29621 Chattooga River Watershed Coalition W. R. McCollum, Jr., Vice President P. 0. Box 2006 Oconee Site Clayton, GA 30525 Duke Energy Corporation P. 0. Box 1439 Seneca, SC 29679

DISTRIBUTION:

Hard copy Docket File PUBLIC PDLR RF M. EI-Zeftawy, ACRS T2E2 R. Zimmerman BElliot D. Matthews C. Grimes T. Essig J. Strosnider G. Bagchi H. Brammer T. Hiltz G. Holahan S. Newberry C. Gratton R. Correia R. Latta J. Peralta J. Moore R. Weisman M. Zobler E. Hackett A. Murphy F. Cherny D. Martin W. McDowell S. Droggitis PDLR Staff H. Berkow D. LaBarge L. Plisco C. Ogle R. Trojanowski M. Scott C. Julian R. Architzel J. Wilson R. Gill, Duke D. Walters, NEI