Confirms 900712 Enforcement Conference in Region II Ofc to Discuss Issues Re Failure to Follow Procedures at Unit 1 on 900611 Which Resulted in Inappropriately Diverting Reactor Coolant Water to Storage Tank
ML15260A133
Person / Time
Site: Oconee, Catawba  Duke Energy icon.png
Issue date: 07/06/1990
From: Reyes L
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Tucker H
DUKE POWER CO.
References
NUDOCS 9007260184
Download: ML15260A133 (6)


Text

JUL 06 1990 Docket Nos. 50-269, 50-270, 50-287 50-413, 50-414 License Nos. DPR-38, DPR-47, DPR-55 NPF-35, NPF-52 Duke Power Company ATTN: Mr. H. B. Tucker, Vice President Nuclear Production Department P. 0. Box 1907 Charlotte, NC 28201-1007 Gentlemen:

SUBJECT:

CONFIRMATION OF MEETING ARRANGEMENTS This confi rms the arrangements made between Mr. R. L. Gill, of Duke Power

Company, and Mr. M. B. Shymlock, of my staff, concerning an Enforcement Conference to be conducted in the Region II Office on July 12, 1990, at 10:00 a.m.

The purpose of the meeting will be to discuss two issues.

The first issue involves a failure to follow procedure at Catawba Unit 1 on June 11, 1990, which resulted in inappropriately diverting reactor coolant water to the Refueling Water Storage Tank. The second issue involves a design deficiency in the Reactor Building Penetration Room Ventilation System at Oconee that could render the system unable to perform its intended safety function ddring a loss of instrument air. The areas we would like to discuss are identified in the enclosures.

Should you have any questions regarding these arrangements, we will be pleased to discuss them.

Sincerely, Luis A. Reyes, Director Division of Reactor Projects

Enclosures:

1. Catawba
2. Oconee cc w/encls:

(See page 2)

'7Y00-"72601C:-:4 900706 FTDR ADOCK 05000269 PDC I ~

I

Duke Power Company 2

cc w/encls:

T. B. Owen, Station Manager Catawba Nuclear Station P. 0. Box 256 Clover, SC 29710 A. V. Carr, Esq.

Duke Power Company P. 0. Box 1007 Charlotte, NC 28201-1007 J. Michael McGarry, III, Esq.

Bishop, Cook, Purcell and Reynolds 1400 L Stre t, NW Washington, D. C. 20005 North Carolina MPA-1 3100 Smoketree Ct., Suite 600 P. 0. Box 29513 Raleigh, NC 27626-0513 Heyward G. Shealy, Chief Bureau of Radiological Health South Carolina Department of Health and Environmental Control 2600 Bull Street Columbia, SC 29201 Richard P. Wilson, Esq.

Assistant Attorney General S. C. Attorney General's Office P. 0. Box 11549 Columbia, SC 29211 Michael Hirsch Federal Emergency Management Agency 500 C Street, SW, Room 840 Washingtonl, D. C. 20472 North Carolina Electric Membershp Corporation 3400 Sumner Boulevard P. 0. Box 27306 Raleigh, NC 27611 (cc w/encls continued -

See page 3)

Duke Power Company 3

JUL 0 6 190 (cc w/encls cont'd)

Saluda River Electric Cooperative, Inc.

P. 0. Box 929 Laurens, SC 29360 S. S. Kilborn, Area Manager Mid-South Area ESSD Projects Westinghouse Electric Corporation MNC West To wer - Bay 239 P. 0. Box 35 Pittsburg, PA 15230 County Manager of York County York County Courthouse York, SC 29745 Piedmont Municipal Power Agency 121 Villagd Drive Greer, SC 29651 H. B. Barron Station Manager Oconee Nuclear Station P. 0. Box 1439 Seneca, SC 29679 County Supervisor of Oconee County Walhalla, SC 29621 Robert B. Borsum Babcock and Wilcox Company Nuclear Power Generation Division Suite 525, 1700 Rockville Pike Rockville, MD 20852 Office of Intergovernmental Relations 116 West Jones Street Raleigh, NC 27603 Manager, LIS NUS Corporation 2536 Count yside Boulevard Clearwater, FL 33515 Paul Guill Duke Power Company P. 0. Box 1007 Charlotte, NC 28201-1007 (cc w/ends continued - See page 4)

Duke Power Company 4

JUL 06 1990 (cc w/encls cont'd)

Karen E. Long Assistant Attorney General N. C. Department of Justice P. 0. Box 629 Raleigh, NC 27602 State of South Carolina bcc w/encls:

K. N. Jabbour, NRR L. Wiens, NRR B. R. Bonser, RH M. B. Shymlock, RH A. R. Herdi, RH Document Control Desk NRC Resident Inspector U.S. Nuclear Regulatory Commission Route 2, Box 179-N York, SC 29745 NRC Resident Inspector U.S. Nuclear Regulatory Commission Route 2, B6x 610 Seneca, SC 29678 RII:DRP RII:D RII:DRP 0S 7//9ock H

0rd7 t 07/1 /90 07/ /90 0 7/ /90

ENCLOSURE 1 CATAWBA FAILURE TO FOLLOW PROCEDURE ON ND PERFORMANCE TEST RESIDUAL HEAT REMOVAL SYSTEM DESCRIPTION DESCRIPTION OF EVENT OPERATOR RESPONSE TO THE EVENT IMMED IATE AND LONG TERM CORRECTIVE ACTIONS.

INCLUDE EVALUATIONS OF THE PRESSURIZER COOLDOWN AND HEATUP, OF THE EXCESSIVE FLOW RATE IN THE ND TRAIN A PUMP AND HEAT EXCHANGER, OF THE LOW PRESSURE OPERATION OF THE NC PUMPS, AND OF THE PIPING AND SUPPORTS ANALYSIS RELATED TO THE OVERPRESSUR IZATION AND POSSIBLE WATER HAMMER.

ROOT CAUSE OF EVENT ASSESSMENT OF SAFETY SIGNIFICANCE.

INCLUDE DISCUSSION OF NC SYSTEM CHANGES, EXCEEDING PRESSURIZER HEATUP AND COOLDOWN LIMITATIONS, AND BRIEF LOSS OF ND SYSTEM CAPABILITY.

ENCLOSURE 2 OCONEE PENETRATION ROOM VENTILATION SYSTEM DESIGN DEFICIENCIES SYSTEM DESCRIPTION IMMEDIATE AND LONG TERM CORRECTIVE ACTIONS DISCUSSION OF OCONEE'S RESPONSE TO GENERIC LETTER 88-14, INSTRUMENT AIR SYSTEM PROBLEMS AFFECTING SAFETY RELATED EQUIPMENT ROOT CAUSE OF DESIGN DEFICIENCY AND WHY THE SIGNIFICANCE OF THE DEFICIENCY HAD NOT BEEN RECOGNIZED SOONER ASSESSMENT OF SAFETY SIGNIFICANCE