Attachment 13 Nuclear Fuel Design Report (Non-Proprietary Version)
A ARE VA ANP-3294NP Nuclear Fuel Design Report Revision 1 Quad Cities Unit 2 Cycle 24 Representative Cycle ATRIUM 10XM Fuel August 2015 AREVA Inc.
(c) 2015 AREVA Inc.
Contrd~ed DocurnerI~:
AREVA Inc.
ANP-3294NP Revision 1 Copyright © 2015 AREVA Inc.
All Rights Reserved AREVA Inc.
Contro~led Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page Nature of Changes Item Page Description and Justification
- 1. Page 2-2 Added proprietary bracket.
AREVA Inc.
Con troled Docw mient Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM I0XM Fuel Page ii Contents 1.0 Introduction ................................................................................... I1-1 2.0 Neutronic Design ............................................................................. 2-I 2.1 Neutronic Design Description ....................................................... 2-I 2.2 Lattice Control Blade Worths and Kinetics Parameters ........................... 2-2 2.3 Enriched Lattice Uncontrolled Reactivities and Isotopic Data .................... 2-3 3.0 References.................................................................................... 3-1 Appendix A Enriched Lattice Hot Uncontrolled Reactivity and LPF Plots ................... A-i Appendix B Enriched Lattice Hot Uncontrolled Reactivity and LPF Tables ................. B-I Appendix C Enriched Lattice Isotopic Data Tables............................................ C-I Appendix D Lattice Enrichment Distribution Maps............................................. D-1 Tables 2.1 Neutronic Design Parameters ............................................................... 2-4 2.2 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE OEM and D120.................................................... 2-7 2.3 Lattice [ J Control Blade Worths at BOL for Control Blade Type GE D160 and D190 Lower Blade..................................... 2-8 2.4 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D190 Blade Tip.................................................... 2-9 2.5 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D230 Lower Blade ............................................... 2-10 2.6 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D230 Blade Tip .................................................. 2-11 2.7 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Bottom Segment .............................. 2-12 2.8 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Main Segment ................................. 2-13 2.9 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82MI and CR82B Blade Main ................................... 2-14 2.10 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Tip..................................... 2-15 AREVA Inc.
Conitrolled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page iii 2.11 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Tip....................................................... 2-16 2.12 Lattice [" ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Main..................................................... 2-17 2.13 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD2 ............................................. 2-18 2.14 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD3 ............................................. 2-19 2.15 Lattice [ ] Kinetics Parameters at BOL......................... 2-19 2.16 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE OEM and 0120................................................... 2-20 2.17 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D160 and 0190 Lower Blade ................................... 2-21 2.18 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0190 Blade Tip................................................... 2-22 2.19 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0230 Lower Blade................................................ 2-23 2.20 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0230 Blade Tip................................................... 2-24 2.21 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Bottom Segment ....... :....................... 2-25 2.22 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Main Segment ................................. 2-26 2.23 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Main ................................... 2-27 2.24 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82MI and CR82B Blade Tip..................................... 2-28 2.25 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Tip....................................................... 2-29 2.26 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Main ..................................................... 2-30 2.27 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD2 ............................................. 2-31 2.28 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD3 ............................................. 2-32 2.29 Lattice [ ] Kinetics Parameters at BOL......................... 2-32 2.30 Lattice [ I Control Blade Worths at BOL for Control Blade Type GE OEM and 0120................................................... 2-33 2.31 Lattice [ I Control Blade Worths at BOL for Control Blade Type GE 0160 and 0190 Lower Blade ................................... 2-34 AREVA Inc.
Coniro~ed Document Nuclear Fuel Design Report AN P-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page iv 2.32 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0190 Blade Tip .................................................. 2-35 2.33 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D230 Lower Blade ............................................... 2-36 2.34 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D230 Blade Tip .................................................. 2-37 2.35 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Bottom Segment .. ........................... 2-38 2.36 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Main Segment ................................. 2-39 2.37 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Main ................................... 2-40 2.38 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82 B Blade Tip ..................................... 2-41 2.39 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Tip....................................................... 2-42 2.40 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Main..................................................... 2-43 2.41 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE M arathon Ultra H D2 ............................................. 2-44 2.42 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD3 ............................................. 2-45 2.43 Lattice [ ] Kinetics Parameters at BOL ....................... 2-45 2.44 Lattice [ I Control Blade Worths at BOL for Control Blade Type GE OEM and 0120 .................................................. 2-46 2.45 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0160 and 0190 Lower Blade ................................... 2-47 2.46 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0190 Blade Tip .................................................. 2-48 2.47 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0230 Lower Blade ............................................... 2-49 2.48 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0230 Blade Tip .................................................. 2-50 2.49 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Bottom Segment .............................. 2-51 2.50 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Main Segment ................................. 2-52 2.51 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82MI and CR82B Blade Main ................................... 2-53 ARE VA Inc.
Contirolled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM I0XM Fuel Page v 2,52 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82MI and CR82B Blade Tip..................................... 2-54 2.53 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Tip....................................................... 2-55 2.54 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Main..................................................... 2-56 2.55 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD2 ............................................. 2-57 2.56 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD3 ............................................. 2-58 2.57 Lattice [ ] Kinetics Parameters at BOL......................... 2-58 2.58 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE OEM and D120............................................................ 2-59 2.59 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D160 and D190 Lower Blade............................................. 2-60 2.60 Lattice [ 3Control Blade Worths at BOL for Control Blade Type GE D190 Blade Tip............................................................ 2-61 2.61 Lattice [ 3Control Blade Worths at BOL for Control Blade Type GE D230 Lower Blade ........................................................ 2-62 2.62 Lattice [ 3Control Blade Worths at BOL for Control Blade Type GE 0230 Blade Tip.................. .......................................... 2-63 2.63 Lattice [ 3Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Bottom Segment........................................ 2-64 2.64 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Main Segment.......................................... 2-65 2.65 Lattice [ 3Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Main ............................................ 2-66 2.66 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR826 Blade Tip .............................................. 2-67 2.67 Lattice [ 3 Control Blade Worths at BOL for Control Blade Type CR99 Blade Tip................................................................ 2-68 2.68 Lattice [ 3Control Blade Worths at BOL for Control Blade Type CR99 Blade Main.............................................................. 2-69 2.69 Lattice [ 3Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD2....................................................... 2-70 2.70 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD3....................................................... 2-71 2.71 Lattice [ 3Kinetics Parameters at BOL........................... 2-71 2.72 Lattice [ 3Control Blade Worths at BOL for Control Blade Type GE OEM and 0120............................................................ 2-72 AREVA Inc.
Contri~.eo~ Documeni Nuclear FuelUnit Quad Cities Design Report 2 Cycle 24 ANP-3294NP Revision 1 Representative Cycle ATRIUM IOXM Fuel Page vi 2.73 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0160 and 0190 Lower Blade............................................. 2-73 2.74 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0190 Blade Tip............................................................ 2-74 2.75 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0230 Lower Blade ........................................................ 2-75 2.76 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0230 Blade Tip............................................................ 2-76 2.77 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Bottom Segment........................................ 2-77 2.78 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Main Segment.......................................... 2-78 2.79 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82 B Blade Main ............................................ 2-79 2.80 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82MI and CR82B Blade Tip .............................................. 2-80 2.81 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Tip................................................................ 2-81 2.82 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Main.............................................................. 2-82 2.83 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD2....................................................... 2-83 2.84 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD3....................................................... 2-84 2.85 Lattice [ ] Kinetics Parameters at BOL........................... 2-84 2.86 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE OEM and 0120............................................................ 2-85 2.87 Lattice [ 3Control Blade Worths at BOL for Control Blade Type GE 0160 and 0190 Lower Blade............................................. 2-86 2.88 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0190 Blade Tip............................................................ 2-87 2.89 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0230 Lower Blade ........................................................ 2-88 2.90 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0230 Blade Tip............................................................ 2-89 2.91 Lattice [ 3Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Bottom Segment........................................ 2-90 2.92 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Main Segment.......................................... 2-91 ARE VA Inc.
Controlled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page vii 2.93 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Main ............................................ 2-92 2.94 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Tip .............................................. 2-93 2.95 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Tip................................................................ 2-94 2.96 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Main.............................................................. 2-95 2.97 Lattice [ J Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD2....................................................... 2-96 2.98 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD3....................................................... 2-97 2.99 Lattice [ ] Kinetics Parameters at BOL .......................... 2-97 2.100 Lattice [ J Control Blade Worths at BOL for Control Blade Type GE OEM and D120................................................... 2-98 2.101 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D160 and D190 Lower Blade ................................... 2-99 2.102 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D190 Blade Tip ................................................. 2-100 2.103 Lattice [ J Control Blade Worths at BOL for Control Blade Type GE D230 Lower Blade .............................................. 2-101 2.104 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D230 Blade Tip ................................................. 2-102 2.105 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Bottom Segment............................. 2-103 2.106 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Main Segment................................ 2-104 2.107 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82MI and CR82B Blade Main.................................. 2-105 2.108 Lattice [ 3Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Tip .......................... .......... 2-106 2.109 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Tip ..................................................... 2-107 2.110 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Main ................................................... 2-108 2.111 Lattice [ 3Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD2 ............................................ 2-109 2.112 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD3............................................ 2-110 2.113 Lattice [ ] Kinetics Parameters at BOL....................... 2-110 AREVA Inc.
Controlled Docum ent Nuclear Fuel Design Report AN P-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page viii 2.114 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE OEM and 0120 .......................................................... 2-111 2.115 Lattice [ 1 Control Blade Worths at BOL for Control Blade Type GE 0160 and D190 Lower Blade ........................................... 2-112 2.116 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0190 Blade Tip .......................................................... 2-113 2.117 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0230 Lower Blade....................................................... 2-1 14 2.118 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D230 Blade Tip .......................................................... 2-115 2.119 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Bottom Segment ...................................... 2-116 2.120 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Main Segment ........................................ 2-117 2.121 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82 B Blade Main........................................... 2-118 2.122 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Tip............................................. 2-119 2.123 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Tip .............................................................. 2-120 2.124 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Main ............................................................ 2-121 2.125 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD2..............,........................................ 2-122 2.126 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD3 ..................................................... 2-123 2.127 Lattice [ JKinetics Parameters at BOL......................... 2-124 2.128 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE OEM and 0120 .......................................................... 2-125 2.129 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0160 and 0190 Lower Blade ........................................... 2-126 2.130 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0190 Blade Tip .......................................................... 2-127 2.131 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0230 Lower Blade....................................................... 2-128 2.132 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0230 Blade Tip .......................................................... 2-129 2.133 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Bottom Segment ...................................... 2-130 AREVA Inc.
Conitrolied Document Nuclear Fuel. Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page ix 2.134 Lattice [ 3Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Main Segment ........................................ 2-131 2.135 Lattice [ 1 Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Main........................................... 2-132 2.136 Lattice [ 3Control Blade Worths at BOL for Control Blade Type CR82MI and CR82B Blade Tip ............................................. 2-133 2.137 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Tip .............................................................. 2-134 2.138 Lattice [ 3Control Blade Worths at BOL for Control Blade Type CR99 Blade Main ............................................................ 2-135 2.139 Lattice [ 3Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD2 ..................................................... 2-136 2.140 Lattice [ 3Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD3 ..................................................... 2-137 2.141 Lattice [ ] Kinetics Parameters at BOL......................... 2-137 2.142 Lattice [ 3Control Blade Worths at BOL for Control Blade Type GE OEM and D120 ................................................. 2-138 2.143 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0160 and D190 Lower Blade.................................. 2-139 2.144 Lattice [ 3Control Blade Worths at BOL for Control Blade Type GE 0190 Blade Tip ................................................. 2-140 2.145 Lattice [ 1Control Blade Worths at BOL for Control Blade Type GE 0230 Lower Blade .............................................. 2-141 2.146 Lattice [ 3Control Blade Worths at BOL for Control Blade Type GE 0230 Blade Tip ................................................. 2-142 2.147 Lattice [ 3Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Bottom Segment............................. 2-143 2.148 Lattice [ 3Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Main Segment................................ 2-144 2.149 Lattice [ 3Control Blade Worths at BOL for Control Blade Type CR82MI and CR82B Blade Main.................................. 2-145 2.150 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Tip ................................... 2-146 2.151 Lattice [ 3Control Blade Worths at BOL for Control Blade Type CR99 Blade Tip ..................................................... 2-147 2.152 Lattice [ 3Control Blade Worths at BOL for Control Blade Type CR99 Blade Main ................................................... 2-148 2.153 Lattice [ 3Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD2 ............................................ 2-149 AREVA Inc.
Controiled Docu ment Nuclear Design FuelUnit Report ANP-3294NP Revision 1 Quad Cities 2 Cycle 24 Representative Cycle ATRIUM 10XM Fuel Page x 2.154 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD3 ............................................ 2-150 2.155 Lattice [ ] Kinetics Parameters at BOL ........................ 2-150 2.156 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE OEM and 0120 ................................................. 2-151 2.157 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D160 and 0190 Lower Blade.................................. 2-152 2.158 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0190 Blade Tip ................................................. 2-153 2.159 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D230 Lower Blade .............................................. 2-154 2.160 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0230 Blade Tip ................................................. 2-155 2.161 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Bottom Segment............................. 2-156 2.162 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Main Segment................................ 2-157 2.163 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Main.................................. 2-158 2.164 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Tip.................................... 2-159 2.165 Lattice [ J Control Blade Worths at BOL for Control Blade Type CR99 Blade Tip ..................................................... 2-160 2.166 Lattice [ I Control Blade Worths at BOL for Control Blade Type CR99 Blade Main ................................................... 2-16 1 2.167 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD2 ............................................ 2-162 2.168 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra H03 ............................................ 2-163 2.169 Lattice [ ] Kinetics Parameters at BOL....................... 2-163 2.170 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE OEM and 0120 .......................................................... 2-164 2.171 Lattice [ I Control Blade Worths at BOL for Control Blade Type GE 0160 and 0190 Lower Blade ........................................... 2-165 2.172 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0190 Blade Tip .......................................................... 2-166 2.173 Lattice [ I Control Blade Worths at BOL for Control Blade Type GE 0230 Lower Blade....................................................... 2-167 2.174 Lattice [ I Control Blade Worths at BOL for Control Blade Type GE 0230 Blade Tip .......................................................... 2-168 AREVA Inc.
Controlced Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM I0XM Fuel Page xi 2.175 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Bottom Segment ...................................... 2-169 2.176 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Main Segment ........................................ 2-170 2.177 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Main........................................... 2-171 2.178 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82MI and CR82B Blade Tip............................................. 2-172 2.179 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Tip .............................................................. 2-173 2.180 Lattice [ JControl Blade Worths at BOL for Control Blade Type CR99 Blade Main ............................................................ 2-174 2.181 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD2 ..................................................... 2-175 2.182 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD3 ..................................................... 2-176 2.183 Lattice [ ] Kinetics Parameters at BOL......................... 2-176 2.184 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE OEM and D1 20 .......................................................... 2-177 2.185 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0160 and 0190 Lower Blade ........................................... 2-178 2.186 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0190 Blade Tip .......................................................... 2-179 2.187 Lattice [ 3Control Blade Worths at BOL for Control Blade Type GE 0230 Lower Blade....................................................... 2-180 2.188 Lattice [ I Control Blade Worths at BOL for Control Blade Type GE 0230 Blade Tip .......................................................... 2-181 2.189 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Bottom Segment ...................................... 2-182 2.190 Lattice [ 3Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Main Segment ........................................ 2-183 2.191 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Main........................................... 2-184 2.192 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Tip............................................. 2-185 2.193 Lattice [ 3Control Blade Worths at BOL for Control Blade Type CR99 Blade Tip .............................................................. 2-186 2.194 Lattice [ 3Control Blade Worths at BOL for Control Blade Type CR99 Blade Main ............................................................ 2-187 AREVA Inc.
Controlled Document Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page xii 2.195 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD2 ...................................................... 2-188 2.196 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD3 ...................................................... 2-189 2.197 Lattice [ ] Kinetics Parameters at BOL......................... 2-189 Figures 2.1 Assembly Type [ ] ............................................ 2-190 2.2 Assembly Type [ ] ............................................ 2-191 2.3 Assembly Type [ ] ............................................ 2-192 2.4 [ ] Fuel Rod Distribution ......................................... 2-193 2.5 [ ] Fuel Rod Distribution ......................................... 2-194 2.6 [ ] Fuel Rod Distribution ......................................... 2-195 2.7 Fuel Rod Axial Description................................................................. 2-196 AREVA Inc.
Cantc e Do u en Nuclear FuelUnit Quad Cities Design Report 2 Cycle 24 ANP-3294NP Revision 1 Representative Cycle ATRIUM 10XM Fuel Page xiii Nomenclature BOL beginning of life BWR boiling water reactor EVC plenum region in a fuel pin modeled as an evacuated section GE General Electric GWd/MTU gigawatt days per metric ton of initial uranium kg/MTU kilograms per metric ton of initial uranium LAR license amendment request LHGR linear heat generation rate LPF local peaking factor MCPR minimum critical power ratio MWd/MTU megawatt days per metric ton of initial uranium NRC Nuclear Regulatory Commission, U. S.
PLFR part-length fuel rod AREVA Inc.
Cetroed Document Nuclear FuelUnit Design Report ANP-3294NP Quad Cities 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 1-1 1.0 Introduction This report provides results of the neutronic design analyses performed by AREVA Inc.
(AREVA) for the Quad Cities Unit 2 fabrication batch QCI2-24 ATRIUM TM* 10XM boiling water reactor (BWR) fuel assemblies for Cycle 24. The fuel designs presented within will be used for the reference cycle to support the License Amendment Request for the inclusion of AREVA's methodology in the Technical Specifications for both Dresden and Quad Cities to support the introduction of the ATRIUM 10OXM fuel design. The mechanical design parameters for the QCI2-24 fuel are summarized in Table 2.1.
Applicable neutronic design criteria are provided in the approved topical report ANF-89-98(P)(A)
Revision 1 and Supplement 1 (Reference 2). Neutronic design analysis methodology used to determine conformance to design criteria has been reviewed and approved by the NRC in the topical report EMF-2158(P)(A) (Reference 3).
The fuel design includes AREVA advanced fuel channels. Mechanical design criteria applicable to the design of these channels have been reviewed and approved by the NRC in Reference 1.
The neutronic design for the fabrication batch includes axially-varying enrichment and gadolinia designs with natural UO 2 blankets at the top and bottom of the assembly. The fabrication batch consists of 96 [ ], 64 [ l and 88 [
] assemblies. Pertinent fuel and reactor core design information associated with this fabrication batch is given in Section 2.0 and in Appendices A through D.
- ATRIUM is a trademark of AREVA Inc.
AREVA Inc.
COntrO~eld *""" "
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 10XM Fuel Page 2-1 2.0 Neutronic Design The results of the Quad Cities Unit 2 fabrication batch QCl2-24 ATRIUM 10OXM neutronic design analyses are presented in this section. The fuel was designed to meet applicable design criteria, as well as reactivity and control requirements. Reactor core loading patterns and the number of assemblies to be loaded will depend upon final cycle energy requirements as specified by the utility. Applicable neutronic design criteria outlined in Reference 2 are summarized below:
- Power Distribution. The local power distribution in the fuel assembly combined with the core power distribution shall result in Linear Heat Generation Rate (LHGR) and Minimum Critical Power Ratio (MCPR) values that are within the limits established for each fuel design.
- Kinetics Parameters. The moderator void reactivity coefficient due to boiling in the active channels and the Doppler fuel temperature reactivity coefficient shall be negative.
The negative void and Doppler reactivity coefficients ensure a negative power coefficient during reactor operation. Additional calculations were performed to show that the assembly average Doppler and void reactivity coefficients remain negative for the life of the assembly. These results demonstrate that the Reference 2 kinetics criteria are met on a bundle average basis.
- Control Blade Reactivity. The design of the fuel assembly and the reactor core loading shall be such that the technical specification shutdown margin requirement is met for all reactor conditions.
2.1 Neutronic Design Description The neutronic design parameters for fabrication batch QCI2-24 are presented in Table 2.1. The key ATRIUM 10XM reload assembly nuclear design characteristics are summarized below:
- The fuel assembly contains [
J. The water channel also serves the function of the spacer capture rod.
- Each fuel assembly has top and bottom natural uranium blankets.
- The plenum/spring region above the PLFRs will be explicitly modeled.
- The enrichments are designed to yield a local power distribution which results in a balanced design relative to MCPR, LHGR, and other reactor operating requirements, e.g., power peaking.
- Gadolinia (Gd 2 0 3 blended with UO 2 ) rods are designed to control assembly reactivity in order to meet reactivity control requirements in the reactor, e.g. cold shutdown margin.
AREVA Inc.
Controaled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM I0XM Fuel Page 2-2
- The reload batch consists of 3 assembly designs which vary axially in enrichment and/or gadolinia. The axial distributions of the lattices in the assemblies are shown in Figures 2.1, 2.2, and 2.3. The fuel rod distribution and axial descriptions are presented in Figures 2.4 through 2.7. The enrichment and gadolinia distribution maps for each of the reload assembly lattices are displayed in Appendix 0.
- The fuel assembly incorporates the AREVA advanced fuel channel which improves uranium utilization. For D-lattice plants, the fuel assembly is offset [ ] toward the control blade.
2.2 Lattice Control Blade Worths and Kinetics Parameters Beginning of life (BOL) lattice reactivities (km) have been calculated for moderator and fuel conditions ranging from cold to hot operating conditions. From these reactivities, BOL control blade worths and kinetics parameters have been determined based on the following control designs:
- GE Marathon and Marathon Ultra HD
- Westinghouse CR82M-1/CR82B
- Westinghouse CR99 The DuraLife 0-100 (OEM) and DuraLife D-120 control blades were found to have equivalent neutronic performance and due to the prevalence of the D-1 00 control blades, it will be used to model both blade types. The same conclusion was reached for the CR82B blade which will be modeled as the more prevalent CR82M-1 blade design. Certain zones of the Marathon Ultra HD were determined to have equivalent neutronic performance as the standard Marathon control blade and have been modeled as such. The other axial zones of the Marathorn Ultra HD blade are explicitly modeled and are presented in this report as HD2 and HD3.
Due to the 3rd party proprietary nature of the control blade designs, control blade dimensional information has been withheld from this report. Kinetics parameters are calculated for fuel temperature (Doppler), moderator void, and moderator temperature. The Doppler reactivity was calculated over a fuel temperature range from hot standby to hot operating. The moderator void reactivity was evaluated between the 0% and 40% voided hot operating cases, and the moderator temperature reactivity was calculated from the cold to hot standby condition. The calculations neglect the spacer material and assume zero void in the coolant outside the fuel AREVA Inc.
ControIled Document Nuclear Fuel Design Report, ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 10XM Fuel Page 2-3 assembly channel as well as inside the internal water channel. The results of these calculations are presented in Tables 2.2 through 2.197.
2.3 Enriched Lattice Uncontrolled Reactivities and Isotopic Data The enriched lattice exposure-dependent uncontrolled reactivities calculated at three void fractions are presented graphically in Appendix A, and in tabular format in Appendix B. The enriched lattice exposure-dependent isotopic data calculated at three void fractions are presented in Appendix C.
AREVA Inc.
DesuignPrmter Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle Talc21Neuronic ATRIUM 10XM Fuel Page 2-4 Table 2.1 Neutronic Design Parameters t [ ]
AREVA Inc,
Controlled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page 2-5 Table 2.1 Neutronic Design Parameters (Continued)
]
AREVA Inc.
Cor d oJIeh< Decu!
- neY.,,
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM I0XM Fuel Page 2-6 Table 2.1 Neutronic Design Parameters (Continued)
Core Data*
Number of fuel assemblies in the core 724 Rated thermal power level, MWt 2957 Rated core flow, Mlbm/hr 98.00 Inlet subcooling, Btu/lbm 24.21 Dome pressure, psia 1015.0 BoroPPM918.0conentrtion BoroPPM(equivalent conentrtion natural 10B)
Intermediate temperature, 0F 200.00 Warm temperature, 0F 358.30
- Some values are representative of rated conditions and may vary depending on the core statepoint.
AREVA Inc.
k,* O,..,Un *,el *t Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-7 Table 2.2 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE OEM and D120 I~aeWrh=kcontroljed - kuncontrolled kcontrolled, kuncontrolled Blade kuncontrolled Worth
____ ____ __ _(,Ak/k)
Cold TModerator= 6 8 ° F TFueI=6 8° F 0.92163 1.08439 -0.1501 0% Void, No xenon Intermediate TModerator=2 0 00 F TFueI=2 0 0° F 0.90643 1.07403 -0.1560 0% Void, No xenon 4 6 Hot Standby TModerator=5 ° F TFueI=546° F 0.85268 1.04096 -0.1809 0% Void, No xenon 4 60 Hot OperatingNoxe Taoderator=5 F TFueI=930 0 F 0.84899 1.03648 -0.1809 0% Void, No xenon Hot Operating0 Taoderator=5 46
° F Tpuei=93O0 F 0.84906 1.03648 -0.1808 0% Void 46 Hot Operating 40 TModeator=5 ° F TFueI=930° F 0.81356 1.02079 -0.2030 40% Void Hot Operating 80 TModerator=5 46
° F TFuC!=930 0 F 0.77089 1 .00157 -0.2303 80% Void AREVA Inc.
Cor~trofle Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-8 Tbe23Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D160 and D190 Lower Blade BaeWrh=kcontrolled - kuncontronled kcontrolledi kuncontrolled Blade kuncontrolled Worth
____ ____ ____(Ak/k) 6 80 0 Cold TModerator= FTmFueI=68 F 0.91987 1.08439 -0.1517 0% Void, No xenon 2 0 00 Intermediate TModerator= F TFueI=2 000 F 0.90473 1 .07403 -0.1576 0% Void, No xenon Hot Standby TModerator= 5 4 6 ° F TFueI=546° F 0.85087 1.04096 -0.1826 0% Void, No xenon 46 Hot OperatingNoxe TModerator=5 ° F T~ueI=930° F 0.84720 1.03648 -0.1826 0% Void, NO xenon Hot Operating 0 TModerator=5 4 6 ° F Tpuei=93O0 F 0.84726 1.03648 -0.1826 0% Void 4 60 Hot Operating 4 o TModerator=5 F TFueI=930° F 0.81117 1.02079 -0.2054 40% Void Hot Operating 80 TModerator=5 46
° F TFue!=9 3 0° F 0.76757 1.00157 -0.2336 80% Void AREVA Inc.
C.* Kr1 *ed Document='
=, * ,',*
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-9 Table 2.4 Lattice [
BOL for Control Blade Type GE D190 Blade Tip
] Control Blade Worths at BaeWrh=kcontrolled " kuncontrolled kcontrolled kuncontrolied Blade kuncontrolled Worth (Ak/k)
Cold TModerator=6 8 ° F TFueI=68° F 0.91662 1.08439 -0.1547 0% Void, No xenon TModerator=2 0 0 Intermediate ° F TFueI=200° F 0.90125 1.07403 -0.1609 0% Void, No xenon Hot Standby TModerator=5 4 6
° F mpuel=546 0 F 0.84574 1.04096 -0.1875 0% Void, No xenon Hot OperatingNoxe TModerator=5 4 6 ° F TF,,ej93 0° F 0.84211 1.03648 -0.1875 0% Void, No xenon Hot Operating 0 TModerator=5 4 6 0 F TFueI=930° F 0.84211 1.03648 -0.1875 0% Void 46 Hot Operating 4 0 TModerator=5 ° F TFueI=930° F 0.80456 1.02079 -0.2118 40% Void 4 6 Hot Operating 80 TModerator=5 ° F TFueI=930° F 0.75901 1.00157 -0.2422 80% Void AREVA Inc.
tr21Ilec Doc ment Nuclear Fuel Design Report AN P-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 10XM Fuel Page 2-10 Table 2.5 BOL Lattice [ ] Control Blade Worths at for Control Blade Type GE D230 Lower Blade BaeWrh=kcontrolled " kuncontrolled kcontrolled kuncontrorled Blade kuncontrolled Worth (Ak/k) 80 Cold TModerator=6 F TFueI=68 0 F 0.90909 1.08439 -0.1617 0% Void, No xenon Intermediate TModerator=2 0 0 0 F TFueI=200° F 0.89357 1.07403 -0.1680 0% Void, No xenon Hot Standby TModerator= 5 4 6 0 F T~ueI=546 0 F 0.83686 1.04096 -0.1961 0% Void, No xenon Hot OperatingNoxe TModerator=5 4 6 ° F TFUeI=9 3 0° F 0.83327 1.03648 -0.1961 0% Void, No xenon Hot Operatingo TModerator=5 4 6 ° F TFuei=930° F 0.83333 1.03648 -0.1960 0% Void Hot Operating 4 0 Tlvoderator=5 4 60 F TFueI=930 0 F 0.79432 1.02079 -0.2219 40% Void 46 Hot Operating 80o TModerator=5 ° F TFue1=930° F 0.74689 1.00157 -0.2543 80% Void AREVA Inc.
rv~ToW~d F)O~ ~ ~t Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 10XM Fuel Page 2-11 Table 2.6 Lattice [
BOL for Control Blade Type GE D230 Blade Tip
] Control Blade Worths at kcontrolled - kuncontroiled kcontrolled kuncontrolled Blade BaeWrhkuncontrolled Worth (Ak/k) 8 Cold TModerator= 8° F Ttuei=68° F 0.91254 1.08439 -0.1585 0% Void, No xenon lntermediate TModerator= 2 O 00 F TFuei=200° F 0.89692 1.07403 -0.1649 0% Void, NO xenon 46 Hot Standby TModerator=5 ° F TFueI=546° F 0.84024 1.04096 -0.1928 0% Void, No xenon 46 Hot OperatingNoxe TModerator=5 ° F TFueI=930° F 0.83663 1.03648 -0.1928 0% Void, No xenon 460 Hot Operating 0 TModerator=5 F TFueI=930° F 0.83663 1.03648 -0.1928 0% Void 46 Hot Operating 4 0 TModerator=5 ° F T~ue0=930° F 0.79840 1.02079 -0.2179 40% Void Hot Operating 80 TModerator=5 46 ° F TF,,i=93O0 F 0.75221 1.00157 -0.2490 80% Void ARE VA Inc.
Contro,!ed ,.octuent Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-12 Table 2.7 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Bottom Segment kControlled - kuncontrolled konrld ku otrld Ba e Blade Worth kuncontrolled cotoldknonr=e ld Worth (Ak/k)
Cold TModerator' 68
° F TFuel=68 0 F 0.92381 1.08439 -0.1481 0% Void, NO xenon Intermediate mModerator= 2 0 0 0 F TFueI=2O 00 F 0.90880 1.07403 -0.1538 0% Void, No xenon Hot Standby TModerator=5 4 6 0 F TFue1=546 0 F 0.85477 1.04096 -0.1789 0% Void, NO xenon Hot OperatingNoxe TModerator=5 46
° F TFueI=9 3O0 F 0.85109 1.03648 -0.1789 0% Void, No xenon 4 60 Hot Operatingo TModerator=5 F TFueI=930 0 F 0.85114 1.03648 -0.1788 0% Void 46 Hot Operating 40 TModerator=5 ° F TFueI=930° F 0.81 524 1.02079 -0.2014 40% Void 4 60 Hot Operating 80 TModerator=5 F Tpuei=930° F 0.77190 1.001 57 -0.2293 80% Void AREVA Inc.
Contr~ole J Dc. men Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 10XM Fuel Page 2-13 Table 2.8 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Main Segment BaeWrh=kcontrolled - kuncontrolled kcontrolled kunoontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator= 6 8 0 F TFueI=68 0 F 0.91638 1.08439 -0.1549 0% Void, No xenon Intermediate TModerator= 2 0 0 0 F TFuei= 2 0 0 ° F 0.90115 1.07403 -0.1610 0% Void, No xenon 4 60 46 Hot Standby TModerator=5 F TFuet=5 ° F 0.84557 1.04096 -0.1877 0% Void, No xenon Hot OperatingNoxe TModierator= 5 4 6° F TFueI=930° F 0.841 94 1.03648 -0.1877 0% Void, NO xenon 46 Hot Operating 0 TModerator=5 ° F TFueI=930° F 0.84200 1.03648 -0.1876 0% Void Hot Operating 40 TModerator=5 460 F TFueI=930 0 F 0.80406 1.02079 -0.2123 40% Void 46 Hot Operating 8 0 TModerator=5 ° F TFueI=930° F 0.75803 1.00157 -0.2432 80% Void AREVA Inc.
C>;n &lled Doc. ~n Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-14 Table 2.9 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82MI and CR82B Blade Main BaeWrh=kcontrolled "kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator= 6 8 0 F TFueI=68° F 0.91744 1.08439 -0.1540 0% Void, NO xenon Intermediate mModerator=2 0 0 ° F TFueI=200° F 0.90242 1.07403 -0.1598 0% Void, No xenon 5 4 60 Hot Standby TModerator= F TFueI=546 0 F 0.84768 1.04096 -0.1857 0% Void, NO xenon 460 Hot OperatingNoxe TModerator=5 F TFueI=9 3 0 ° F 0.84404 1.03648 -0.1857 0% Void, No xenon 4 60 Hot Operating 0 TModerator=5 F TFueI=9 3 00 F 0.84411 1 .03648 -0.1856 0% Void 460 Hot Operating 40 TModerator=5 F TFueI=930° F 0.80712 1.02079 -0.2093 40% Void Hot Operating 80 mModerator=5 4 60 F TFoU6=9 3O0 F 0.76192 1.00157 -0.2393
- 80% Void ____
AREVA Inc.
Cot ro !ed Dru-en Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-15 Table 2.10 Lattice [ ] Control BOL for Control Blade Type CR82M1 and CR82B Blade Tip Blade Worths at Bld oh=kcontrolled - kuncontrolled kcontrolled kUncontrolled Blade kuncontrolled Worth
____ ____ ____(Ak/k)
Cold TModerator=6 8° F TFueI-68° F 0.93855 1.08439 -0.1345 0% Void, No xenon Intermediate TModerator= 2 0 00 F TFueI=2 000 F 0.92425 1.07403 -0.1395 0% Void, NO xenon Hot Standby TModerator= 5 4 6 0 F Tiruei=546° F 0.87450 1.04096 -0.1599 0% Void, NO xenon 46 Hot OperatingNoxe TModerator=5 ° F TFueI=930° F 0.87069 1.03648 -0.1600 0% Void, NO xenon 46 Hot Operatingo TModerator=5 ° F TFue,=930° F 0.87069 1.03648 -0.1600 0% Void 46 Hot Operating 40 TModerator=5 ° F TFueI=930° F 0.83893 1.02079 -0.1782 40% Void 46 Hot Operating 80 TModerator=5 ° F TFueI=930° F 0.80063 1.00157 -0.2006 80% Void AREVA Inc.
Contro~led D~ocument Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-16 Table 2.11 Lattice [ ] Control BOL for Control Blade Type CR99 Blade Tip Blade Worths at kcontraaled "kuncontrolled kcontrolled kuncontrolled Blade BaeWrh= kuncontrolled Worth (Ak/k)
Cold TModerator= 6 8 0 F TFueI=68° F 0.91546 1.08439 -0.1558 0% Void, No xenon Intermediate TModerator=2 0 0
° F mFuet=200 0 F 0.90020 1.07403 -0.1618 0% Void, No xenon Hot Standby TModerator= 5 4 6 0 F TF,,eI=546° F 0.84454 1.04096 -0.1887 0% Void, No xenon 46 Hot OperatingNoxe TModerator=5 ° F TFueI=9 3 O0 F 0.84090 1.03648 -0.1887 0% Void, NO xenon 60 Hot Operating0 TModerator=54 F TFueI=930° F 0.84098 1.03648 -0.1886 0% Void 46 Hot Operating 4 o TModerator=5 ° F TFueI=930 0 F 0.80292 1.02079 -0.2134 40% Void 4 60 Hot Operating 80 Taoderator=5 F TFueI=930° F 0.75614 1.00157 -0.2450 80% Void AREVA Inc.
l :rUzjied CDoou er Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-17 Table 2.12 Lattice [
BOL for Control Blade Type CR99 Blade Main
] Control Blade Worths at BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrogled Blade kuncontrogged Worth (Ak/k)
Cold TModerator=6 8 ° F TFueI=6 8
° F 0.91390 1.08439 -0.1572 0% Void, No xenon 200 Intermediate TModerator=2 0 0 ° F TFUep= °F 0.89861 1.07403 -0.1633 0% Void, No xenon Hot Standby TModerator= 5 4 6 ° F TFueI=546° F 0.84256 1.04096 -0.1906 0% Void, NO xenon 46 Hot OperatingNoxe TModerator=5 ° F TFueg=9 3 0 ° F 0.83894 1.03648 -0.1906 0% Void, No xenon 4 60 Hot Operatingo TModerator=5 F TFueI=9300 F 0.83902 1.03648 -0.1905 0% Void 4 60 Hot Operating 40 TModerator=5 F TFueI=930° F 0.80050 1.02079 -0.2158 40% Void Hot Operating 80 TModerator=5 4 6 ° F mFuje=930° F 0.75308 1 .00157 -0.2481 80% Void AREVA Inc.
.~ ~
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-18 Table 2.13 Lattice [ ] Control BOL for Control Blade Type GE Marathon Ultra HD2 Blade Worths at BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k) 68 Cold TModerator= ° F TFuej=68° F 0.93694 1.08439 -0.1360 0% Void, No xenon Intermediate TModerator= 2 0 0 0 F TFue1=200° F 0.92232 1.07403 -0.1412 0% Void, NO xenon 46 Hot Standby TModeretor=5 ° F T~uei=546° F 0.87056 1.04096 -0.1637 0% Void, No xenon Hot OperatingNoxe mModeretor=5 46
° F TFue1=9 3 0° F 0.86679 1.03648 -0.1637 0% Void, No xenon 4 60 Hot Operating0 Taoderator=5 F TFueI=930 0 F 0.86684 1.03648 -0.1637 0% Void Hot Operating 4 0 Taoderator= 5 4 6
° F TFuej=930° F 0.83298 1.02079 -0.1840 40% Void 4 60 Hot Operating 80 TModeretor=5 F TFueI=930° F 0.79177 1.00157 -0.2095 80% Void AREVA Inc.
ControHed Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-19 Table 2.14 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD3 BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrollod Blade kuncontrolled Worth (Ak/k)
Cold mModerator= 6 8 0 F T~ueI=68 0 F 0.95946 1.08439 -0.1152 0% Void, No xenon Intermediate mModerator=2 0 00 F TFueI=200° F 0.94554 1.07403 -0.1196 0% Void, No xenon Hot Standby TModerator= 5 4 6 0 F TFuel=546° F 0.89776 1.04096 -0.1376 0% Void, NO xenon 46 Hot OperatingNoxe TModerator=5 ° F TFueI=9 3O0 F 0.89382 1.03648 -0.1376 0% Void, No xenon 46 Hot Operating 0 TModerator=5 ° F TFueI= 9 3 O0 F 0.89387 1.03648 -0.1376 0% Void Hot Operating 40 TModertor=5 46
° F TFuei=93 0 ° F 0.86394 1.02079 -0.1537 40% Void Hot Operating 80 TModerator=5 4 6 ° F T*uei=93O0 F 0.82730 1.00157 -0.1740 80% Void Table 2.15 Lattice [ ] Kinetics Parameters at BOL Kinetics Kinetics Parameter = akPrmer kKIk (Ak/k)
Dplr= kHotOperatingNoXe - kHotStandby 1 .03648 1.04096 -0.0043 Dopper
=kHotStanldby Mdrtrld= kHotOperating40 - kHotOperating0 1.02079 1.03648 -0.0151 Modertorvid =kHotOperating0 Mdrtreemue-kHotStandby - kCold 1 .04096 1.08439 -0.0401 Modeatorempratue = kcold AREVA Inc.
Contro~ed D~urn~mt Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-20 Table 2.16 BOL Lattice [ ] Control Blade Worths at for Control Blade Type GE OEM and D120 BaeWrh=kcontroljed - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator= 6 8 0 F TFuei=68° F 0.91223 1.07416 -0.1507 0% Void, No xenon Intermediate Taoderator=2 0 0 ° F TFuei=2 0 0 ° F 0.89663 1 .06324 -0.1567 0% Void, No xenon 46 Hot Standby mModerator=5 ° F TFueI=5 4 6 ° F 0.84066 1.02690 -0.1814 0% Void, No xenon 46 Hot OperatingNoxe TModerator=5 ° F TFueI=930° F 0.83698 1.02242 -0.1814 0% Void, No xenon Hot Operating 0 TMederator=5 4 6° F TFuei=930 0 F 0.83704 1.02242 -0.1813 0% Void Hot Operating 40 TModerator=5 4 60 F TFuel= 9 3 O0 F 0.80062 1 .00489 -0.2033 40% Void Hot Operating ao TModeretoj=54 6 0 F T,,ei=9300 F 0.75747 0.98363 -0.2299 80% Void AREVA Inc.
Q 3led
_ Documen
~ft Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-21 Table 2.17 Lattice [ ] Control BOL for Control Blade Type GE D160 and D190 Lower Blade Blade Worths at kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade BaeWrh= kuncontrolled Worth (Ak/k)
Cold TModerator= 6 8 0 F TFueI=68 0 F 0.91050 1.07416 -0.1524 0% Void, NO xenon Intermediate TModerator= 2 0 0 ° F TFueI=2 0 0 ° F 0.89495 1.06324 -0.1583 0% Void, No xenon 60 Hot Standby TModerator=5 4 F mFueI=546 0 F 0.83889 1.02690 -0.1831 0% Void, No xenon 46 Hot Operatingaoxe TModerator=5 ° F TFueC=930° F 0.83523 1.02242 -0.1831 0% Void, No xenon 46 Hot Operating 0 TModerator=5 ° F TFueI=930 0 F 0.83528 1 .02242 -0.1830 0% Void 46 Hot Operating 40 TModerator=5 ° F TFueI=930° F 0.79829 1.00489 -0.2056 40% Void Hot Operating 8a0 TMoaerator=5 46
° F TFueI=930 0 F 0.75424 0.98363 -0.2332 80% Void AREVA Inc.
Controi~eA Docurrent Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-22 Table 2.18 Lattice [ ] Control BOL for Control Blade Type GE D190 Blade Tip Blade Worths at BaeWrh=kcontroljed " kuncontrolled kcontrojled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator=6 8 0 F TFueI=68° F 0.90725 1.07416 -0.1554 0% Void, NO xenon Intermediate TModeretor=2 0 0 0 F TF,,e= 2 0 0 ° F 0.89150 1.06324 -0.1615 0% Void, No xenon Hot Standby TModerator=5 4 6
° F TFueI=546 0 F 0.83384 1.02690 -0.1880 0% Void, No xenon 4 60 Hot Operatingaoxe TModerator=5 F TFueI=930° F 0.83021 1.02242 -0.1880 0% Void, No xenon 4 6 Hot Operatingo TModerator=5 ° F TFue0=930° F 0.83021 1.02242 -0.1880 0% Void 46 Hot Operating 4 o TModerator=5 ° F TFueI=930° F 0.79180 1.00489 -0.21 20 40% Void Hot Oprtigo TModerator=5 46
° F TFueI=9 3 0 ° F 0.74592 0.98363 -0.2417 80% Void ARE VA Inc.
Cont o1d L)OCument Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-23 Table 2.19 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D230 Lower Blade Baekcontralled - kuncontrolled kControlled kuncontroijed Blade Wrh- kuncontrolled Worth (Ak/k)
Cold mModerator=6 8 0
F TFueI=6 8 0 F 0.89983 1.07416 -0.1623 0% Void, No xenon Intermediate TModerator=
2 00
° F TFueI=2 0 0 ° F 0.88392 1.06324 -0.1686 0% Void, No xenon Hot Standby TModerator= 5 4 6 0 F TFueI=54 6 ° F 0.82510 1. 02690 -0.1965 0% Void, NO xenon Hot OperatingNoxe TModerator=5 4 6 ° F TFueI=930° F 0.82152 1.02242 -0.1965 0% Void, NO xenon 4 60 Hot Operating 0 TModerator=5 F TFue1=930° F 0.82157 1.02242 -0.1965 0% Void 46 Hot Operating 40 TModerator=5 ° F TFrueI=930° F 0.78177 1.00489 -0.2220 40% Void Hot Operating 80 TModerator=5 46
° F TFueI=9 3 O0 F 0.73408 0.98363 -0.2537 80% Void AREVA Inc.
Co trotid D.cu ment' Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-24 Table 2.20 Lattice [ ] Control Blade BOL for Control Blade Type GE D230 Blade Tip Worths at BaeWrh=kcontroIled - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k) 6 0 Cold TModerator= 8° F TFuej=68 F 0.90320 1.07416 -0.1592 0% Void, No xenon Intermediate TModerator=2 0 00 F TFuel=200 0 F 0.88721 1.06324 -0.1656 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFueI=546° F 0.82842 1.02690 -0.1933 0% Void, No xenon Hot Operatingaoxe Tuodterator=5 4 60 F TFuei=93O0 F 0.82481 1.02242 -0.1933 0% Void, No xenon ____
460 Hot Operatingo TModerator=5 F TFueI=930° F 0.82481 1.02242 -0.1933 0% Void_____
4 Hot Operating 40 Taoderator=5 6° F TFueI=930° F 0.78577 1.00489 -0.2180 40% Void 46 Hot Operating 80 T~oderator=5 ° F TFueI=930° F 0.73931 0.98363 -0.2484 80% Void AREVA Inc.
C v~ro~ ~ed Documen~
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-25 Table 2.21 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Bottom Segment kcontrolled - kuncontrolled kotrld knotrld Ba e Blade Worth = _____________cnrldknonofe kuncontrolled Bae Worth (Ak/k)
Cold TModerator=6 8 0 F TFue=68° F 0.91443 1.07416 -0.1487 0% Void, No xenon Intermediate TModerator=2 0 0
° F mFuei=2 0 0 ° F 0.89902 1.06324 -0.1545 0% Void, No xenon 46 Hot Standby TModerator=5 ° F TFuel=546° F 0.84279 1.02690 -0.1793 0% Void, No xenon Hot Operatingaoxe TModerator=5 4 6
° F TFue6 = 9 3O0 F 0.83912 1.02242 -0.1793 0% Void, No xenon 4
Hot Operatingo TModerator=5 6° F TFueI=930° F 0.83917 1.02242 -0.1792 0% Void 4
Hot Operating 40 TModerator=5 6° F TFuel=930° F 0.80236 1 .00489 -0.2015 40% Void 460 Hot Operating 80 Tuoderator=5 F TFuel=930° F 0.75859 0.98363 -0.2288 80% Void AREVA Inc.
oKIied Doumn Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-26 Table 2.22 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Main Segment BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k) 68 Cold TModerator= ° F TFuej=68° F 0.90706 1.07416 -0.1556 0% Void, NO xenon Intermediate TModerator=2 0 0 ° F TFueI=2 0 00 F 0.89143 1.06324 -0.1616 0% Void, No xenon Hot Standby TModerator=5 4 60 F TFueI=5 4 6 ° F 0.83369 1.02690 -0.1882 0% Void, No xenon 46 Hot OperatingNoxe TModerator=5 ° F TFueI=930° F 0.83007 1.02242 -0.1881 0% Void, No xenon 46 Hot Operatingo TModerator=5 ° F TFue1=930° F 0.83012 1.02242 -0.1881 0% Void 4 60 Hot Operating 4 o Taoderator=5 F TF,,e=930° F 0.79135 1.00489 -0.2125 40% Void 4 60 Hot Operating 80 mModerator=5 F TFueI=930° F 0.74500 0.98363 -0.2426 80% Void AREVA Inc.
CoKro~Ld Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-27 Table 2.23 Lattice [ ] Control Blade BOL for Control Blade Type CR82M1 and CR82B Blade Main Worths at BaeWrh=kcontrolled - kuncontrolled kcontrorled kuncontrotled Blade kuncontrolled Worth (Ak/k)
Cold TModerator=6 8 ° F TFueI=68° F 0.90817 1.07416 -0.1545 0% Void, No xenon Intermediate TModerator=2 0 00 F TFueI=2 0 0 ° F 0.89276 1.06324 -0.1603 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFueI=546° F 0.83589 1.02690 -0.1860 0% Void, No xenon 46 Hot OperatingNoxe TModerator=5 ° F TFueI=930 0 F 0.83225 1.02242 -0.1860 0% Void, No xenon 4 60 Hot Operating 0 TModerator=5 F TFueI=930 0 F 0.83232 1.02242 -0.1859 0% Void 4 60 Hot Operating 4 0 mModerator=5 F TFueI=930° F 0.79449 1.00489 -0.2094 40% Void 46 Hot Operating 80 TModerator=5 ° F TFue,=930° F 0.74892 0.98363 -0.2386 80% Void AREVA Inc.
ControoieJ Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM I0XM Fuel Page 2-28 Table 2.24 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82MI and CR82B Blade Tip BaeWrh=kcontroljed - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
TModerator=6 8 0 6 8 Cold F TFuelI ° F 0.92901 1.07416 -0.1351 0% Void, No xenon Intermediate mModerator=2 0 0 ° F TFueI=2 00 ° F 0.91429 1.06324 -0.1401 0% Void, No xenon Hot Standby TModerator= 5 4 6 ° F TFueI=5 4 6 ° F 0.86223 1.02690 -0.1604 0% Void, No xenon Hot OperatingNoxe TModerator= 5 4 6 ° F TFueI=930° F 0.85843 1.02242 -0.1604 0% Void, No xenon Hot Operating0 TModerator=5 4 6 ° F T~uej=930 0 F 0.85843 1.02242 -0.1604 0% Void 4 60 Hot Operating 40 Tuoderator=5 F TFueI=9 3 00 F 0.82562 1.00489 -0.1784 40% Void 46 Hot Operating 8 0 TModerator=5 ° F TFueI=930 0 F 0.78665 0.98363 -0.2003 80% Void AREVA Inc.
Co~stolle mocu Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-29 Table 2.25 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Tip BaeWrh=kcontrolled " kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Aklk)
Cold TModerator= 6 8 0 F TFueI=68 0 F 0.90614 1.07416 -0.1564 0% Void, No xenon Intermediate TModerator=2 0 0 ° F TFue}= 2O 00 F 0.89050 1.06324 -0.1625 0% Void, No xenon Hot Standby TModerator= 5 4 6 ° F TFuel=546 0 F 0.83270 1.02690 -0.1891 0% Void, No xenon 46 Hot Operatingaoxe T~oderator=5 ° F TFueI= 9 3O0 F 0.82907 1.02242 -0.1891 0% Void, No xenon 4 60 Hot Operating 0 TModerator=5 F TFueI=930° F 0.829"14 1.02242 -0.1890 0% Void 46 Hot Operating 40 Taoderator=5 ° F TFu 0 1=930° F 0.79024 1 .00489 -0.2136 40% Void Hot Operating 80 mModerator=5 46
° F TFuel=93O0 F 0.74313 0.98363 -0.2445 80% Void AREVA Inc.
C oqt~ro~lec Docc ,ner Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-30 Table 2.26 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Main BaeWrh kControlled - kuncontrolled kcontrojled kUncontrolled Blade kuncontrolled Worth
____ ____ ____(Ak/k)
Cold TModerator= 6 80 F TFueI=68 0 F 0.90461 1.07416 -0.1578 0% Void, No xenon Intermediate TModerator=2 0 0 ° F TFueI=2 0 0 ° F 0.88893 1.06324 -0.1639 0% Void, No xenon Hot Standby Taoderator= 5 4 6 ° F TFueI=546 0 F 0.83075 1.02690 -0.1910 0% Void, No xenon 46 0 Hot OperatingNoxe Taoderator=5 ° F TFueI=93 ° F 0.82714 1.02242 -0.1910 0% Void, No xenon 46 Hot Operating 0 T~oderator=5 ° F TFueI=9300 F 0.82722 1.02242 -0.1909 0% Void 46 Hot Operating 40 TModerator=5 ° F TFueI=930° F 0.78787 1.00489 -0.2160 40% Void 46 Hot Operating 80 TModerator=5 ° F TF,,e=930 0 F 0.74014 0.98363 -0.2475 80% Void AREVA Inc.
OontrWo~ed Deu me nt Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-31 Table 2.27 Lattice ( ] Control Blade BOL for Control Blade Type GE Marathon Ultra HD2 Worths at BaeWrh=kcontrolled - kuncontrolled kcontrofjed kuncontrorled Blade kuncontrojied Worth (Ak/k) 6 80 80 Cold TModerator= F TFueI=6 F 0.92739 1.07416 -0.1366 0% Void, No xenon 2 0 00 Intermediate TModerator= F TFueI=200° F 0.91234 1.06324 -0.1419 0% Void, No xenon 460 Hot Standby TModerator=5 F TFuej=546 0 F 0.85826 1.02690 -0.1642 0% Void, No xenon Hot OperatingNoxe TModerator=5 46
° F TFuei=93 0 ° F 0.85449 1.02242 -0.1643 0% Void, No xenon 46 Hot Operatingo TModerator=5 ° F TFueI=930° F 0.85454 1.02242 -0.1642 0% Void 46 Hot Operating 40 TModerator=5 ° F TFueI=930° F 0.81 965 1.00489 -0.1843 40% Void Hot Operating 80 TModerator=5 4 6° F TFueI=9 3 O0 F 0.77781 0.98363 -0.2092 80% Void AREVA Inc.
ContrcAed Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-32 Table 2.28 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD3 kcontrolled - kuncontrolied kcontrolled kuncontrolted Blade BaeWrh= kuncontrolled Worth (Ak/k)
Cold TModerator=6 8 0 F TFuej=68 0 F 0.94964 1.07416 -0.1159 0% Void, NO xenon 0 00 Intermediate Taoderator=2 F TFueI=200° F 0.93528 1.06324 -0.1203 0% Void, No xenon 4 6 Hot Standby TModerator=5 ° F T~uei=546° F 0.88500 1.02690 -0.1382 0% Void, No xenon Hot Operatingaoxe Tuocierator=546 0 F TFueI=93 0 ° F 0.88106 1.02242 -0.1383 0% Void, No xenon 4 60 Hot Operating 0 TModerator=5 F TFueI=930° F 0.88111 1.02242 -0.1382 0% Void 46 Hot Operating 4 0 TModertor=5 ° F TFeI=930° F 0.84995 1.00489 -0.1542 40% Void Hot Operating 80 TModerator= 5 4 6 0 F TFueI=930° F 0.81238 0.98363 -0.1741 80% Void Table 2.29 Lattice [ ] Kinetics Parameters at BOL Kinetics Kinetics Parameter-=kk aaee k* I% k*(Ak/k)
Dplr= kHotaperatingNoXe - kHotStanldby 1.02242 1.02690 -0.0044 Doppler
=kHotStandby Mdrtr 0 d= kHotOperating40 - kHotOperatingo 1 .00489 1 .02242 -0.0171 Modertorvid =kHotOperatingo Moeao~meaue- kHotStandby - kCold 1.02690 1.07416 -0.0440 Modeatorempratue = kcotd AREVA Inc.
Co ntr o~Ld DocL ienst Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-33 Table 2.30 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE OEM and D120 BaeWrh=kcontrotled " kuncontrolled kcontrolled kuncontrolled Blade Baeorh= kuncontroijed Worth (Ak/k)
Cold TModerator=6 8 ° F TFue*=68° F 0.83558 1.00046 -0.1648 0% Void, No xenon Intermediate TModerator=2 0 00 F TFueI=200° F 0.82081 0.99033 -0.1712 0% Void, No xenon.
4 60 Hot Standby TModerator=5 F TFueI=546 0 F 0.77149 0.95996 -0.1963 0% Void, No xenon Hot OperatingaoxC TModerator=5 46
° F Tpuej=989 0 F 0.76793 0.95554 -0.1963 0% Void, No xenon 4 60 Hot Operatingo Tuoderator=5 F T~uei=989 0 F 0.76799 0.95554 -0.1963 0% Void 46 Hot Operating 40 TModerator=5 ° F TFueI=989° F 0.73622 0.94208 -0.2185 40% Void Hot Operating 80 4 60 TModerator=5 F TFueI=989° F 0.69768 0.92519 -0.2459 80% Void AREVA Inc.
o itroed oue?
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-34 Table 2.31 Lattice [ ] Control Blade at BOL for Control Blade Type GE D160 and D190 Lower Blade Worths laeWrh=kcontrolled " kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Aldk)
Cold TModerator=6 8 0 F TFueI=68 0 F 0.83402 1.00046 -0.1664 0% Void, No xenon Intermediate TModerator=2 0 0 ° F TFueI= 2 00
° F 0.81932 0.99033 -0.1727 0% Void, No xenon Hot Standby Taoderator=5 46
° F TFue*=5 4 6° F 0.76994 0.95996 -0.1979 0% Void, No xenon 4 60 Hot OperatingNoxe TModerator=5 F TFueI=989° F 0.76639 0.95554 -0.1979 0% Void, No xenon 46 Hot Operating0 TModerator=5 ° F TFUe0=9890 F 0.76644 0.95554 -0.1979 0% Void Hot Operating 4 0 TModerator=5 4 6 ° F TFueI=989 0 F 0.734 12 0.94208 -0.2208 40% Void Hot Operating 8o 460 89 TModerator=5 F TF,,e=9 °F 0.69471 0.92519 -0.2491 80% Void AREVA Inc.
C:~cLd oc ei.r Nuclear FuelUnit Design Report ANP-3294NP Quad Cities 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-35 Table 2.32 Lattice [ 1 Control Blade Worths at BOL for Control Blade Type GE D190 Blade Tip BaeWrh=kcontrolled " kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Aklk)
Cold mModerator= 6 8 ° F TFueI=68° F 0.83073 1.00046 -0.1696 0% Void, No xenon Intermediate TModerator=2 0 0
° F TFuel= 2O 0 ° F 0.81583 0.99033 -0.1762 0% Void, No xenon 4 6 Hot Standby TModerator=5 ° F TFuei=546° F 0.76502 0.95996 -0.2031 0% Void, No xenon Hot OperatingNoxe Thocterator=546° F TFuef=9 8 9 ° F 0.76151 0.95554 -0.2031 0% Void, No xenon Hot Operating 0 TModerator=5 4 60 F TFueI= 9 9 8 °F 0.76 151 0.95554 -0.2031 0% Void 46 Hot Operating 40 TModerator=5 ° F TFueI=989° F 0.72783 0.94208 -0.2274 40% Void 46 Hot Operating 80 TMoaerator=5 ° F TFueI=989° F 0.68661 0.92519 -0.2579 80% Void AREVA Inc.
Controlied Docur ient Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-36 Table 2.33 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D230 Lower Blade BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade kuncontroiled Worth (Ak/k)
Cold TModerator=6 8 0 F TF,,e=68° F 0.82347 1.00046 -0.1769 0% Void, No xenon Intermediate TModerator= 2 0 0
° F TFueI=2 0 0 ° F 0.80841 0.99033 -0.1837 0% Void, No xenon 46 Hot Standby TModerator=5 ° F TFueI=546° F 0.75642 0.95996 -0.2120 0% Void, No xenon Hot OperatingNoxe Taoderator=5 46
° F TFueI=9 8 9 ° F 0.75296 0.95554 -0.2120 0% Void, No xenon 460 Hot Operating 0 TModerator=5 F TF,,eI989 0 F 0.75301 0.95554 -0.2119 0% Void 46 Hot Operating 4 o TModerator=5 ° F TFueI=989° F 0.71795 0.94208 -0.2379 40% Void 46 Hot Operating 80 TModerator=5 ° F TFueI=989° F 0.67493 0.92519 -0.2705 80% Void AREVA Inc.
C* ntrofle,n- D-cun Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-37 Table 2.34at Lattice [ ] Control Blade Worths BOL for Control Blade Type GE D230 Blade Tip BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade kUncontrolled Worth (Ak/k)
Cold mModerator= 6 8° F TFuei=68° F 0.82668 1.00046 -0.1737 0% Void, No xenon Intermediate Taoderetor=2 0 0 0 F TFueI=2 0 00 F 0.81154 0.99033 -0.1805 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFuel=546° F 0.75961 0.95996 -0.2087 0% Void, No xenon 4 60 Hot OperatingNoxe TModerator=5 F TFueI=989° F 0.75612 0.95554 -0.2087 0% Void, No xenon 4 60 Hot Operatingo TModerator=5 F TFueI=989° F 0.75612 0.95554 -0.2087 0% Void 460 Hot Operating 40 TModeretor=5 F TFueI=989° F 0.72180 0.94208 -0.2338 40% Void 4 60 Hot Operating 80 TModerator=5 F TFueI=989° F 0.67997 0.92519 -0.2651 80% Void AREVA Inc.
~LWP~r~ L Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 10XM Fuel Page 2-38 Table 2.35 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Bottom Segment BaeWrh kcontrolled " kUncontroIled kcontrolled kuncontrolled Blade kuncontroIled Worth (Ak/k)
Cold TModerator=6 8 ° F TFueI=68° F 0.83759 1.00046 -0.1628 0% Void, No xenon Intermediate T~oderator=2 0 0 ° F TFueI=200° F 0.82308 0.99033 -0.1689 0% Void, No xenon 460 Hot Standby TModerator=5 F TFueI=546° F 0.77370 0.95996 -0.1940 0% Void, No xenon 46 Hot Operatingaoxe Taoderator=5 ° F TFuei=989° F 0.77014 0.95554 -0.1940 0% Void, No xenon Hot Operating 0 TModerator=5 4 6 ° F TFueI=989° F 0.77019 0.95554 -0.1940 0% Void 46 Hot Operating 40 Taoderator=5 ° F TFu*I=989° F 0.73807 0.94208 -0.2165 40% Void Hot Operating 8 0 TModerator=5 46
° F TFueI=98 9 ° F 0.69893 0.925 19 -0.2446 80% Void AREVA Inc.
vCotoiLd ,Do~un,c Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 10XM Fuel Page 2-39 Table 2.36 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Main Segment kcontrolled " kuncontroijed kcontrolled kunoontrolled Blade BaeWrh= kuncontrolled Worth (Ak/k)
Cold TModerator=6 8
° F TFueI=68° F 0.83037 1.00046 -0.1700 0% Void, No xenon Intermediate TModerator=2 0 0 ° F TFuei=200° F 0.81562 0.99033 -0.1764 0% Void, No xenon 460 Hot Standby TModerator=5 F TFuej=546° F 0.76481 0.95996 -0.2033 0% Void, No xenon 4 60 Hot OperatingNoxe TModerator=5 F TFueI=989 0 F 0.76131 0.95554 -0.2033 0% Void, No xenon 4 60 Hot Operating 0 TModerator=5 F TFuel=989 0 F 0.76136 0.95554 -0.2032 0% Void Hot Operating 40 Taoderator=5 46
° F TFueI=989 0 F 0.72733 0.94208 -0.2280 40% Void 46 Hot Operating 80 TModerator=5 ° F TFueI=989° F 0.68568 0.92519 -0.2589 80% Void AREVA Inc.
Lo Lrc JOODc
~ment Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 10XM Fuel Page 2-40 Table 2.37 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Main BaeWrh=kcontrojjed - kuncontroaled kcontrolled kuncontrolled Blade kuncontrotled Worth (Ak/k)
Cold mModerator=6 8 ° F TFuei=6 8 ° F 0.83158 1.00046 -0.1688 0% Void, NO xenon Intermediate mModerator=2 0 0 ° F TFueI= 2 0 0 ° F 0.81704 0.99033 -0.1750 0% Void, No xenon 4 60 Hot Standby Taoderator=5 F TFue!=546 0 F 0.76700 0.95996 -0.2010 0% Void, No xenon 46 Hot OperatingNXox TModerator=5 ° F TFueI=989° F 0.76349 0.95554 -0.2010 0% Void, No xenon 4 60 Hot Operatingo TMederator=5 F TFueI=989 0 F 0.76356 0.95554 -0.2009 0% Void 46 Hot Operating 4 0 TModerator=5 ° F Tiruei=989° F 0.73042 0.94208 -0.2247 40% Void 4 60 Hot Operating 80 TModerator=5 F TFueI=989° F 0.68950 0.92519 -0.2547 80% Void AREVA Inc.
Con~r~: Doci lei Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 10XM Fuel Page 2-41 Table 2.38 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82MI and CR82B Blade Tip BaeWrh=kcontrolled " kuncontroaled kcontroilect kuncontrolledt Blade kuncontrolled Worth (Ak/k)
Cold TModerator=6 8° F TFueI=68 0 F 0.85199 1.00046 -0.1484 0% Void, No xenon Intermediate TModerator=2 0 00 F TFuel=200° F 0.83815 0.99033 -0.1537 0% Void, No xenon Hot Standby TModerator=5 4 60 F TFueI=5 4 60 F 0.79282 0.95996 -0.1741 0% Void, NO xenon 46 Hot OperatingNoxe TModerator=5 ° F TFueI=989 0 F 0.78914 0.95554 -0.1741 0% Void, No xenon 46 Hot Operatingo TModerator=5 ° F TFueI=989° F 0.78914 0.95554 -0.1741 0% Void 46 Hot Operating 40 TModerator=5 ° F TFuej=989 0 F 0.76090 0.94208 -0.1923 40% Void 4 60 Hot Operating 80 TModerator=5 F TFueI=989° F 0.72653 0.92519 -0.2147 80% Void AREVA Inc.
.C .,.O DOCumet iT Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page_2-42 Table 2.39 Lattice [ ] Control at BOL for Control Blade Type CR99 Blade Tip Blade Worths Bldkorh= controlled - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator= 6 8 0 F TFuel=68° F 0.82982 1 .00046 -0.1706 0% Void, NO xenon Intermediate mModerator=2 0 00 F TFueI=200° F 0.81503 0.99033 -0.1770 0% Void, No xenon 4 60 Hot Standby TModerator=5 F Tpue =546° 1 F 0.76407 0.95996 -0.2041 0% Void, No xenon 989 Hot OperatingNoxe TModerator=5 4 6 0 F TFueI= °F 0.76056 0.95554 -0.2041 0% Void, NO xenon 46 Hot Operating 0 TModerator=5 ° F TFue1=989 0 F 0.76063 0.95554 -0.2040 0% Void 46 Hot Operating 4 0 TModerator=5 ° F T~uel=989° F 0.72648 0.94208 -0.2289 40% Void Hot Operating 80 TModerator=5 4 6 ° F TFueI=989° F 0.68409 0.92519 -0.2606 80% Void ARE VA Inc.
ControHed Doc umen'~
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-43 Table 2.40 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Main laeW rh= kcontrolled " kuncontrolled kcontrollod kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator=6 8 0 F TFuel=68 F 0.82830 1.00046 -0.1721 0% Void, NO xenon Intermediate TModerator=2 0 0 ° F TFueI=200° F 0.81348 0.99033 -0.1786 0% Void, NO xenon 46 Hot Standby TModerator=5 ° F TFueI=546° F 0.76217 0.95996 -0.2060 0% Void, NO xenon 546 Hot OperatingNoxe TModerator= ° F TFueI=989 0 F 0.75868 0.95554 -0.2060 0% Void, NO xenon Hot Operating 0 TModerator=5 4 6
° F TFueI=989 0 F 0.75875 0.95554 -0.2059 0% Void 4 6 Hot Operating 40 TModerator=5 ° F TF,,eI=989° F 0.72416 0.94208 -0.2313 40% Void 4 60 Hot Operating 80 TModerator=5 F TFue1=989° F 0.68116 0.92519 -0.2638 80% Void AREVA Inc.
Onc o~ed Do~;ument Nuclear Fuel Design Report ANP-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page 2-44 Table 2.41 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD2 BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k) 6 80 Cold TModerator= F TFUC=68° F 0.85060 1.00046 -0.1498 0% Void, No xenon Intermediate TModerator=2 0 0 ° F TFueI=200° F 0.83644 0.99033 -0.1554 0% Void, No xenon 460 Hot Standby TModerator=5 F TF,,eI=546° F 0.78913 0.95996 -0.1780 0% Void, No xenon 4
Hot OperatingNoxe TModerator=5 6° F TFueI=989° F 0.78548 0.95554 -0.1780 0% Void, No xenon Hot Operating 0 TModerator=5 4 6 ° F TFueI=989° F 0.78553 0.95554 -0.1779 0% Void 4 60 Hot Operating 40 TModerator=5 F TFueI=989° F 0.75531 0.94208 -0.1983 40% Void Hot Operating 8o TModerator=5 4 60 F TFueI=989 0 F 0.71816 0.92519 -0.2238 80% Void AREVA Inc.
Contro~Ied uo ; ~
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 10XM Fuel Page 2-45 Table 2.42 at BOL Lattice [
for Control ] Control Blade Type GE Marathon Blade Ultra HD3Worths BaeWrh=kcontrolled - kuncontrolled koontrolled kuncontrolled Blade kuncontrolled Worth
____ ____ ____(Ak/k)
Cold TModerator=6 8 ° F Tpuel=68° F 0.87287 1.00046 -0.1275 0% Void, No xenon Intermediate TModerator=2 0 0 0 F TFueI=2 0 0 ° F 0.85936 0.99033 -0.1323 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFue!=546° F 0.81576 0.95996 -0.1502 0% Void, NO xenon Hot OperatingNoxe TModerator=5 4 6 ° F TFueI=989° F 0.81193 0.95554 -0.1503 0% Void, No xenon Hot Operatingo TModerator=5 4 6 ° F TFueI=98 9 ° F 0.81197 0.95554 -0.1502 0% Void 46 Hot Operating 4 0 mModerator=5 ° F TFuej=989° F 0.78542 0.94208 -0.1663 40% Void 46 Hot Operating 80 TModerator=5 ° F TFueI=989° F 0.75256 0.92519 -0.1866 80% Void Table 2.43 Lattice [ ] Kinetics Parameters at BOL Kinetics Kinetics Parameter = ~Paaee k*k k (Ak/k)
Dplr= kHotOperatingNoXe - kHotStandby 0.95554 0.95996 -0.0046 Dopper
=kHotStandby Mdrtrld kHotOperatjng4o kHotOperating0 0.94208 0.95554 -0.0141 Modertorvid =kHotOperating0 kaotStandby - kCoid 0.95996 1.00046 -0.0405 ModeratorTemperature - kcold AREVA Inc.
Corr*e 02 It!*,
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-46 Table 2.44 Lattice [
BOL for Control Blade Type GE OEM and D120
] Control Blade Worths at BaeWrh=kcontroljed - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Aklk)
Cold TModerator=6 8 0 F TFuel=68° F 0.84699 1.00447 -0.1568 0% Void, No xenon 2 0 00 Intermediate TModerator= F TFueI=2 0 0 0 F 0.83226 0.99467 -0.1633 0% Void, No xenon 4 6 Hot Standby Taoderator=5 ° F TFue*=546° F 0.78393 0.96653 -0.1889 0% Void, NO xenon Hot OperatingNoxe TModerator=5 4 6
° F TFueI=98 9 ° F 0.78047 0.96226 -0.1889 0% Void, No xenon Hot Operating0 Taoderator=5 4 6 ° F TFue1=989° F 0.78053 0.96226 -0.1889 0% Void Hot Operating 4 o TModerator=5 4 6
° F TFueI=98 9 ° F 0.74807 0.94979 -0.2124 40% Void 46 Hot Operating 80 Tuoderator=5 ° F TFueI=989° F 0.70599 0.93242 -0.2428 80% Void AREVA Inc.
~ tK ~LA Doc~. ~ 1~
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-47 TableBOL2.45forLattice [ ] Control Blade Worths at Control Blade Type GE 0160 and D190 Lower Blade kcontrolled - kuncontrolled kcontrolled kuncontroilecd Blade Blade Worth = njnrjeWrh (Ak/k)
Cold TModerator= 6 8 ° F TFUeL=6 8 ° F 0.84552 1.00447 -0.1582 0% Void, NO xenon Intermediate TModerator=2 0 0 0 F TFueI=20 0 ° F 0.83086 0.99467 -0.1647 0% Void, NO xenon 54 6 0 Hot Standby TModerator= F TFueI=5 4 6 0 F 0.78248 0.96653 -0.1904 0% Void, NO xenon 46 Hot OperatingNoxe TModerator=5 ° F TFueI=989° F 0.77903 0.96226 -0.1904 0% Void, No xenon 46 Hot Operating 0 TModerator=5 ° F T~uei=989° F 0.77908 0.96226 -0.1904 0% Void Hot Operating 40 mModerator=5 4 60 F TFuel=9 8 9 ° F 0.74605 0.94979 -0.2145 40% Void Hot Operating 80 TModerator=5 4 6 0 F TFueI=9 8 9 ° F 0.70307 0.93242 -0.2460 80% Void AREVA Inc.
Controiied Domn Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-48 Table 2.46 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D190 Blade Tip BaeWrh=kcontrolled - kuncontrolied kcontrolled kuncontrolled Blade kuncontrolled Worth (Aklk) 68 0 Cold mModerator= ° F TFUeI=68 F 0.84243 1.00447 -0.1613 0% Void, No xenon Intermediate TModerator=2 0 0 0 F TFueI200° F 0.82760 0.99467 -0.1680 0% Void, No xenon Hot Standby TModerator= 5 4 6 ° F TFueI=546° F 0.77787 0.96653 -0.1952 0% Void, No xenon 4 6 Hot Operatingaoxe TModerator=5 ° F TFuej=989° F 0.77445 0.96226 -0.1952 0% Void, NO xenon 46 Hot Operating 0 TModerator=5 ° F TFueI=989° F 0.77445 0.96226 -0.1952 0% Void 46 Hot Operating 40 Taoderator=5 ° F TFueI=989 0 F 0.74002 0.94979 -0.2209 40% Void 4 60 Hot Operating 80 Tuederator=5 F TFueI=989 0 F 0.69506 0.93242 -0.2546 80% Void AREVA Inc.
Contro~ed ~iocument Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-49 Table 2.47BOL Lattice [
for Control Blade Type GE D230 ] Control Blade Worths at Lower Blade BaeWrh=kcontrolled " kuncontrolled koontrolled kuncontroj led Blade kuncontrolled Worth (Ak/k)
Cold TModerator= 6 8 ° F TFueI=6 80 F 0.83560 1.00447 -0.1681 0% Void, NO xenon Intermediate TModerator=2 0 0 0 F TFueI=200° F 0.82056 0.99467 -0.1750 0% Void, No xenon 46 46 Hot Standby TModerator=5 ° F TFue1=5 ° F 0.76957 0.96653 -0.2038 0% Void, No xenon 46 Hot Operatingaoxe Taoderator=5 ° F Tpuei=989° F 0.76619 0.96226 -0.2038 0% Void, No xenon 46 Hot Operatingo TModerator=5 ° F TFUe1=989° F 0.76624 0.96226 -0.2037 0% Void 46 Hot Operating 4 o TModerator=5 ° F TFueI=989 0 F 0.73033 0.94979 -0.2311 40% Void 46 Hot Operating 80 TModerator=5 ° F TFueI=989 0 F 0.68339 0.93242 -0.2671 80% Void AREVA Inc.
Con~To~ed Docurr~en~
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page 2-50 Table 2.48 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D230 Blade Tip BaeWrh=kcontrolled - kuncontroIled kcontroljed kuncontrolied Blade kuncontrolled Worth (Ak/k)
Cold TModerator= 6 80 F mFuel=68 0 F 0.83862 1.00447 -0.1651 0% Void, No xenon.
Intermediate TModerator=2 0 0 0 F TFueI=200° F 0.82351 0.99467 -0.1721 0% Void, No xenon Hot Standby TModerator=5 4 60 F TFuel=5 4 6° F 0.77262 0.96653 -0.2006 0% Void, No xenon 46 Hot OperatingNoxe TModerator=5 ° F TFuei=989° F 0.76923 0.96226 -0.2006 0% Void, No xenon 46 Hot Operating 0 TModerator=5 ° F T~uei=989 0 F 0.76923 0.96226 -0.2006 0% Void 4 6 Hot Operating 4 0 TModerator=5 ° F TFueI=989° F 0.73408 0.94979 -0.2271 40% Void Hot Operating 8 0 TModerator=5 46
° F TFue8=9890 F 0.68839 0.93242 -0.2617 80% Void AREVA Inc.
CcntrcA ~ed Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-51 Table 2.49 Lattice [ ] Control BOL for Control Blade Type GE Marathon Blade Bottom Segment Blade Worths at BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolied Worth (Ak/k) 80 Cold TModerator=6 F TFueI=68° F 0.84900 1.00447 -0.1548 0% Void, No xenon Intermediate TModerator=2 0 0 0 F mFueI=200 0 F 0.83457 0.99467 -0.1610 0% Void, No xenon 46 Hot Standby T~oderator=5 ° F TFueI=546° F 0.78636 0.96653 -0.1864 0% Void, No xenon Hot OperatingNoxe Taederator= 5 4 6 ° F TFuei=989° F 0.78290 0.96226 -0.1864 0% Void, NO xenon_____
Hot Operating 0 TModerator=5 46
° F TFueI=989 0 F 0.78295 0.96226 -0.1863 0% Void 4 60 Hot Operating 40 T~oderator=5 F TFueI=989° F 0.75018 0.94979 -0.2102 40% Void 4 60 Hot Operating 80 TModerator=5 F TFueI=989° F 0.70745 0.93242 -0.2413 80% Void AREVA Inc.
uOn *,rolea~ DOOclin1[.
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-52 Table 2.50 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Main Segment BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold mModerator=6 8 ° F TFue=68° F 0.84210 1.00447 -0.1616 0% Void, No xenon Intermediate TModerator= 2 0 0 0 F TFueI=200° F 0.82743 0.99467 -0.1681 0% Void, No xenon Hot Standby TModerator= 5 4 6 ° F TFueI=546° F 0.77771 0.96653 -0.1954 0% Void, No xenon Hot OperatingNoxe mModerator= 5 4 6 ° F TFueI=989 0 F 0.77430 0.96226 -0.1953 0% Void, No xenon 46 Hot Operating 0 mModerator=5 ° F TFueI=989° F 0.77435 0.96226 -0.1953 0% Void 4 6 Hot Operating 4 0 TModerator=5 ° F TFueI=989° F 0.73957 0.94979 -0.2213 40% Void 46 Hot Operating5 0 TModerator=5 ° F TFueI=989° F 0.69416 0.93242 -0.2555 80% Void AREVA Inc.
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-53 Table 2.51 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Main BaeWrh=kcontrolled - kuncontroIled kcontrolled kuncontrolled Blade kuncontronled Worth (Ak/k)
Cold TModerator=6 8 0 F TFueI=68° F 0.84330 1.00447 -0.1605 0% Void, No xenon Intermediate TModerator= 2 0 0 ° F TFueI=200° F 0.82884 0.99467 -0.1667 0% Void, No xenon 546 Hot Standby TModerator= ° F TFueI=546° F 0.77998 0.96653 -0.1930 0% Void, NO xenon Hot OperatingNoxe mModerator= 5 4 6 ° F T~uei=989° F 0.77656 0.96226 -0.1930 0% Void, No xenon 46 Hot Operating 0 TModerator=5 ° F T~uei=989 0 F 0.77662 0.96226 -0.1929 0% Void Hot Operating 4 0 TModerator=5 46
° F T~ue,=9 8 9° F 0.74280 0.94979 -0.2179 40% Void 46 98 0 Hot Operating80o TModerator=5 ° F TFuel= 9 F 0.69812 0.93242 -0.2513 80% Void AREVA Inc.
C Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-54 Table 2.52 Lattice [ J Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Tip laeW th= kcontroljed - kuncontrolled kcontrolled kuncontrolled Blade BaeWrh= kuncontrolled Worth (Ak/k) 6 80 Cold TModerator= F TFueI=68° F 0.86249 1.00447 -0.1414 0% Void, No xenon Intermediate TModerator= 2 0 0 0 F TFueI=200° F 0.84876 0.99467 -0.1467 0% Void, No xenon 46 Hot Standby TModerator=5 ° F TFue!=546° F 0.80465 0.96653 -0.1675 0% Void, No xenon 46 Hot OperatingNoxe TModerator=5 ° F TFue0=989° F 0.80108 0.96226 -0.1675 0% Void, No xenon Hot Operating 0 TModerator=5 4 6 ° F TFueI=989° F 0.80108 0.96226 -0.1675 0% Void Hot Operating 40 TModerator=5 4 6 ° F TFueI=989° F 0.77243 0.94979 -0.1867 40% Void 46 Hot Operating 80 TModerator=5 ° F TFueI=989° F 0.73494 0.93242 -0.2118 80% Void AREVA Inc.
Gontro~ed F)r~rmmeni Nuclear Fuel Unit Design Report ANP-3294NP Quad Cities 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-55 Table 2.53 Lattice [ ] Control BOL for Control Blade Type CR99 Blade Tip Blade Worths at BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth
________________(Ak/k) 80 Cold TModierator=6 F TFueI=68° F 0.84161 1.00447 -0.1621 0% Void, No xenon Intermediate TModerator=2 0 00 F TFueI=200 0 F 0.82689 0.99467 -0.1687 0% Void, No xenon Hot Standby TModerator= 5 4 6 ° F TFue0=546° F 0.77705 0.96653 -0.1960 0% Void, No xenon Hot OperatingNoxe TModerator=5 46
° F TFueI=9890 F 0.77364 0.96226 -0.1960 0% Void, No xenon 46 Hot Operating 0 TModerator=5 ° F TFueI=989 0 F 0.77370 0.96226 -0.1960 0% Void 4 60 Hot Operating 40 TModerator=5 F TFueI=989° F 0.73886 0.94979 -0.2221 i40% Void 4 60 Hot Operating 80 TModerator=5 F TFueI=989° F 0.69270 0.93242 -0.2571 80% Void AREVA Inc.
Controlied Soc- ment Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-56 Table 2.54 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Main BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator=6 8
° F TFueI=68° F 0.84019 1.00447 -0.1636 0% Void, No xenon Intermediate TModerator= 2 0 0
° F TFueI=200° F 0.82543 0.99467 -0.1701 0% Void, No xenon Hot Standby TModerator=5 4 60 F TFuet=5460 F 0.77524 0.96653 -0.1979 0% Void, No xenon Hot OperatingNoxC TModerator= 5 4 6 ° F TFuei=989° F 0.771 84 0.96226 -0.1979 0% Void, No xenon Hot Operating0 Taoderator=5 460 F TFueI=989 0 F 0.77191 0.96226 -0.1978 0% Void 46 Hot Operating 40 mModerator=5 ° F TFueI=989° F 0.73660 0.94979 -0.2245 40% Void Hot Operating 80 TModerator=5 46
° F TFueI=9 8 9° F 0.68978 0.93242 -0.2602 80% Void AREVA Inc.
Controlled Docun ment Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-57 Table 2.55 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD2 Bld oh k~ontrolled - kuncontrolled kcontroj led kunoontroi led Blade
- kuncontrolled Worth (Ak/k) 68 0 Cold mModerator= ° F mFuel=68 F 0.86138 1.00447 -0.1424 0% Void, No xenon lntermediate T~oderator= 2 O 00 F TFueI=2 0 00 F 0.84730 0.99467 -0.1482 0% Void, No xenon 4 60 Hot Standby Taoderator=5 F TFueI=546° F 0.80124 0.96653 -0.1710 0% Void, No xenon 4 6 890 Hot Operatingaoxe Taoderator=5 ° F TFue1=9 F 0.79769 0.96226 -0.1710 0% Void, No xenon 4 60 Hot Operating 0 TModerator=5 F TFueI=9 8 9 0 F 0.79774 0.96226 -0.1710 0% Void Hot Operating 40 T~oderator=5 4 6 ° F TFuel=989° F 0.76708 0.94979 -0.1924 40% Void 46 Hot Operating 80 TModerator=5 ° F TFuel=989° F 0.72665 0.93242 -0.2207 80% Void AREVA Inc.
Co~viro.Abd D ......
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-58 Table 2.56 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD3 kcontroiled - kuncontroiled kcontrolled kuncontrolled Blade BaeWrh= kuncontrolled Worth (Ak/k) 68 Cold TModerator= ° F TFuel=68° F 0.88248 1.00447 -0.1215 0% Void, No xenon Intermediate TModerator= 2 00
° F TFueI=200° F 0.86911 0.99467 -0.1262 0% Void, No xenon Hot Standby TModerator= 54 6 ° F TFueI=546 0 F 0.82689 0.96653 -0.1445 0% Void, No xenon Hot OperatingNoxe TModerator-- 5 4 6 0 F TFueI=989° F 0.82318 0.96226 -0.1445 0% Void, N/o xenon Hot Operating 0 TModerator-- 5 4 6 0 F TF'uei=989 0 F 0.82322 0.96226 -0.1445 0% Void Hot Operating 40 TModeretor= 5 4 6 0 F TFue1=989° F 0.79656 0.94979 -0.1613 40% Void Hot Operating 80 TModerator=5 46
° F TFueI=989 0 F 0.76097 0.93242 -0.1839 80% Void Table 2.57 Lattice [ ] Kinetics Parameters at BOL Kinetics Kinetics Parameter = kk aaee kKI k* (Ak/k)
Dplr= kHotOperatingNoXe "kHotStanldby 0.96226 0.96653 -0.0044 kHotStandby Mertr 0 d= kHetOperating4o - k~otOperating0 0.94979 0.96226 -0.0130 Modertorv~d =kHotOperating0 kHotStandby - kCold 0.96653 1.00447 -0.0378 ModeratorTemperature - kcold AREVA Inc.
Co ntro led Doc ument Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-59 Table 2.58 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE OEM and D120 BaeWrh=kcontrolled " kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k) 80 Cold TModerator= 6 F TFueI=68 0 F 0.89564 1.04805 -0.1454 0% Void, No xenon Intermediate TModerator=2 0 00 F TFueI=200 0 F 0.88221 1.03979 -0.1515 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFueI=546° F 0.83156 1.01261 -0.1788 0% Void, NO xenon 4 60 Hot OperatingNoxe TModerator=5 F TFueI=989° F 0.82785 1.00810 -0.1788 0% Void, No xenon 46 Hot Operatingo T~oderator=5 ° F TFuej=989° F 0.82791 1.00810 -0.1787 0% Void Hot Operating 40 Taodlerator=5 46
° F T~ue1=989° F 0.78978 0.99291 -0.2046 40% Void Hot Operating5 0 TModerator=5 4 6
° F TFueI=989° F 0.73936 0.97092 -0.2385 80% Void AREVA Inc.
rUled Dowmer~
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-60 Table 2.59 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D160 and D190 Lower Blade kcontrolled - kuncontroijed kcontrolled kuncontrolled Blade BaeWrh= kuncontrolled Worth (Ak/k)
Cold TModerator=6 8° F TFuet=6 8 ° F 0.89413 1.04805 -0.1469 0% Void, NO xenon Intermediate TModerator= 2 0 0 0 F TFUOI=200° F 0.88076 1.03979 -0.1529 0% Void, No xenon Hot Standby TModer~ator=5 4 6 ° F TFueI=546° F 0.83003 1.01261 -0.1803 0% Void, No xenon 4 60 Hot OperatingNoxe TModerator=5 F TFue1=989° F 0.82634 1.00810 -0.1803 0% Void, NO xenon Hot Operatingo TModerator=5 4 6 ° F TFueI=989° F 0.82638 1.00810 -0.1803 0% Void 46 Hot Operating 4 0 TModerator=5 ° F TFueI=989° F 0.78765 0.99291 -0.2067 40% Void 46 Hot Operating 80 TModerator=5 ° F TFueI=989° F 0.73625 0.97092 -0.2417 80% Void AREVA Inc.
Conirolled ........ n Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-61 Table 2.60 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D190 Blade Tip BaeWrh=kcontrolied - kuncontrolled kcontrolled kuncontrolled Blade kuncontrojied Worth
____ ____ ____(Ak/k)
Cold TModerator= 6 8 ° F TFueI=68° F 0.89122 1.04805 -0.1496 0% Void, No xenon Intermediate TModerator=2 0 0 ° F TFueI=200° F 0.87766 1.03979 -0.1559 0% Void, No xenon 4 60 Hot Standby mModerator=5 F TFueI=546° F 0.82545 1.01261 -0.1848 0% Void, No xenon 46 Hot OperatingNoxe TModerator=5 ° F TFuej=989° F 0.82179 1.00810 -0.1848 0% Void, No xenon Hot Operatingo TModerator= 5 4 6 0 F TFueI=989° F 0.82179 1.00810 -0.1848 0% Void 46 Hot Operating 40 TModerator=5 ° F TFueI=989° F 0.78153 0.99291 -0.2129 40% Void 4 60 89 Hot Operating s0 TModerator=5 F TFueI=9 °F 0.72801 0.97092 -0.2502 80% Void AREVA Inc.
Co'~tr-~L< r~ocun~ent Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-62 Table 2.61 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D230 Lower Blade BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrorled Blade kuncontrolled Worth (Ak/k) 68 0 Cold TModerator= ° F TFueI=68 F 0.88447 1.04805 -0.1561 0% Void, No xenon Intermediate TModerator= 2 0 0 0 F TFueI=200 0 F 0.87072 1.03979 -0.1626 0% Void, NO xenon 4 60 Hot Standby TModerator=5 F TFuej=546° F 0.81714 1.01261 -0.1930 0% Void, NO xenon 46 9 Hot OperatingNoxe TModerator=5 ° F TFueI= 89° F 0.81352 1.00810 -0.1930 0% Void, No xenon Hot Operating 0 iTModerator=5 4 6 0 F TFueI=9890 F 0.81357 1.00810 -0.1930 0% Void 46 Hot Operating 40 TModerator=5 ° F TF~eI=989° F 0.771 70 0.99291 -0.2228 40% Void 46 Hot Operating8 o T~oderator=5 ° F TFUeI=989° F 0.71605 0.97092 -0.2625 80% Void AREVA Inc.
Controlled cien Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-63 Table 2.62 Lattice [
BOL for Control Blade Type GE 0230 Blade Tip
] Control Blade Worths at BaeWrh=kcontrolled " kuncontrolled kcontroiled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator=6 8 ° F mFueI=6 8 ° F 0.88766 1 .04805 -0.1530 0% Void, No xenon Intermediate Taoderator=2 0 0 ° F TFueI=200° F 0.87382 1.03979 -0.1596 0% Void, No xenon 46 46 Hot Standby TModerator=5 ° F TFuel=5 ° F 0.82036 1.01261 -0.1899 0% Void, No xenon 46 Hot OperatingNoxe Tuoderator=5 ° F TFuej=989° F 0.81672 1.00810 -0.1898 0% Void, No xenon 4 6 Hot Operatingo TModerator=5 ° F TFueI=989° F 0.81672 1.00810 -0.1898 0% Void 46 Hot Operating 40 TModerator=5 ° F TFueI=989 0 F 0.77565 0.99291 -0.2188 40% Void 46 Hot Operating 80 TModerator=5 ° F TFueI=989° F 0.72128 0.97092 -0.2571 80% Void AREVA Inc.
Con {rc .Vd Docunent Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-64 Table 2.63 Lattice BOL for Control
[ ] Control Blade Worths at Blade Type GE Marathon Blade Bottom Segment BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator=6 8
° F TFueI=6 8° F 0.89760 1.04805 -0.1436 0% Void, No xenon Intermediate TModerator=2 0 0 ° F TFueI200° F 0.88443 1.03979 -0.1494 0% Void, No xenon Hot Standby TModerator= 5 4 6 ° F TFueI=5 4 6 0 F 0.83395 1.01261 -0.1764 0% Void, No xenon 46 Hot Operatingaoxe Taoderator=5 ° F TFueI=989° F 0.83024 1.00810 -0.1764 0% Void, No xenon 4 60 Hot Operating 0 Taoderator=5 F TFueI=989 0 F 0.83029 1.00810 -0.1764 0% Void 46 Hot Operating 40 TModerator=5 ° F TFueI=989° F 0.79189 0.99291 -0.2025 40% Void Hot Operating 80 TModerator=5 46
° F TFueI=9 8 90 F 0.74086 0.97092 -0.2369 80% Void AREVA Inc.
Tontod Doc rnenc Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 10XM Fuel Page 2-65 Table 2.64 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Main Segment BaeWrh=kcontro!led - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator=6 80 F TFuei=68 0 F 0.89077 1.04805 -0.1501 0% Void, No xenon Intermediate TModerator= 2 0 0 ° F T~uei=200° F 0.87738 1.03979 -0.1562 0% Void, No xenon 4 60 Hot Standby TModerator=5 F T~uel=546° F 0.82519 1.01 261 -0.1851 0% Void, No xenon Hot OperatingNoxe TModerator= 54 6 ° F TFueI=9 8 9 ° F 0.82154 1.00810 -0.1851 0% Void, NO xenon Hot Operatingo TModerator=5 4 60 F TFueI= 9 89
° F 0.82159 1.00810 -0.1850 0% Void Hot Operating 40 TModerator=5 4 60 F T~uei=989° F 0.78100 0.99291 -0.2 134 40% Void Hot Operating 80 TModerator=5 4 60 F TFueI=989 0 F 0.72709 0.97092 -0.2511 80% Void ARE VA Inc.
GuAt oWJed Dcm cvei Nuciear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1I Representative Cycle ATRIUM 10XM Fuel Page 2-66 Table 2.65 Lattice [ J Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Main BaeWrh=kcontrolled " kuncontrolled kcontrolled kuncontrolled Blade kuncontroIled Worth (Ak/k)
Cold TModerator=6 8 ° F TFuel= 6 8 0 F 0.891 99 1.04805 -0.1489 0% Void, No xenon Intermediate TModerator=2 0 0 0 F TF,,ei=200 0 F 0.87879 1.03979 -0.1548 0% Void, NO xenon Hot Standby TModerator=5 4 60 F TFueZ=546 0 F 0.82754 1.01261 -0.1828 0% Void, NO xenon 60 Hot OperatingNoxe TModerator= 5 4 F TFuel= 9 8 9 ° F 0.82387 1.00810 -0.1827 0% Void, No xenon Hot Operating 0 TModerator=5 4 6 0 F TFueI=9 8 90 F 0.82394 1.00810 -0.1827 0% Void 4
Hot Operating 4 o TModerator=5 6° F TF,, 0 1989° F 0.78439 0.99291 -0.2100 40% Void 46 Hot Operating 80 TModerator=5 ° F mFuel=989° F 0.73127 0.97092 -0.2468 80% Void AREVA Inc.
Cor t olJed Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-67 TableBOL2.66forLattice [ ] Control Blade Worths at Control Blade Type CR82MI and CR82B Blade Tip BaeWrh=kcontrolled - kuncontrolled kcontrolred kuncontrolled Blade kuncontrolled Worth
____ ____ ____(Ak/k) 68 Cold mModerator= ° F mFueI=68° F 0.91 097 1.04805 -0.1308 0% Void, NO xenon Intermediate mModerator= 2 0 0 0 F TFueI=20 00 F 0.89855 1 .03979 -0.1358 0% Void, No xenon 46 Hot Standby TModertor=5 ° F TFueI=546 0 F 0.85243 1.01261 -0.1582 0% Void, No xenon Hot OperatingNoxe 'TModeretor=5 4 6 ° F Tpuej=989° F 0.84861 1.00810 -0.1582 0% Void, NO xenon 4 60 Hot Operating0 TModerator=5 F TFueI=989° F 0.84861 1.00810 -0.1582 0% Void 46 Hot Operating 40 mModerator=5 ° F TFueI=989° F 0.81469 0.99291 -0.1795 40% Void 4 60 Hot Operating 80 TModeretor=5 F TFueI=9 8 9 ° F 0.76931 0.97092 -0.2077 80% Void AREVA Inc.
~vowx~i L)OCUmen~ ,-'~
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-68 Table 2.67 Lattice [
BOL for Control Blade Type CR99 Blade Tip
] Control Blade Worths at BaeWrh=kControlled " kuncontrolled kcontroliecd kuncontrorled Blade kuncontrolled Worth (Ak/k) 68 Cold TModerator= ° F TFueI=68° F 0.89046 1.04805 -0.1504 0% Void, No xenon Intermediate TModerator= 2 0 0 ° F T~ueI=200° F 0.87703 1.03979 -0.1565 0% Void, No xenon 46 Hot Standby mMederator=5 ° F TFuel=546° F 0.82472 1.01261 -0.1855 0% Void, No xenon Hot OperatingNoxe TModerator=5 4 6 0 F TFuei=989° F 0.82106 1.00810 -0.1855 0% Void, No xenon 4 60 Hot Operating 0 TModerator=5 F TFueI=989° F 0.82113 1.00810 -0.1855 0% Void 460 Hot Operating 40 TModerator=5 F TFue*=989° F 0.78049 0.99291 -0.2139 40% Void 46 Hot Operating 80 TModerator=5 ° F TFueI=989° F 0.72582 0.97092 -0.2524 80% Void AREVA Inc.
f{O**L !*"DOCuLen Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page 2-69 Table 2.68 Lattice [ ] Control BOL for Control Blade Type CR99 Blade Main Blade Worths at BaeWrh=kcontrolled - kuncontrolied kcontrolled kunoontrolled Blade kuncontrolled Worth (Ak/k) 6 80 Cold TModerator= F TFuej=68° F 0.88904 1.04805 -0.1517 0% Void, No xenon Intermediate TModerator=2 0 0 0 F TFueI=2 0 0 0 F 0.87557 1.03979 -0.1579 0% Void, No xenon Hot Standby TModerator= 5 4 6 0 F TFueI=546 0 F 0.82288 1.01 261 -0.1874 0% Void, No xenon 46 Hot OperatingNoxe TModerator=5 ° F TFueI=989° F 0.81 923 1.00810 -0.1873 0% Void, No xenon Hot Operatingo TModerator=5 4 6 ° F TFueI=989 0 F 0.81930 1.00810 -0.1873 0% Void Hot Operating 4 0 TModeratoT=5 4 6 ° F TF~eI=989° F 0.77817 0.99291 -0.2163 40% Void Hot Operating 80 TModerator=5 4 6 0 F TF,,I=989° F 0.72278 0.97092 -0.2556 80% Void AREVA Inc.
Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-70 Table 2.69 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD2 BaeWrh=kcontrolled - kuncontrolled kcontrolaed kuncontroljed Blade kuncontronled Worth (Ak/k)
Cold TModerator= 6 8 0 F TFuel=68 0 F 0.90970 1.04805 -0.1320 0% Void, No xenon Intermediate TModerator=
2 0 00 F TFueI=2 0 0 0 F 0.89690 1.03979 -0.1374 0% Void, No xenon 46 Hot Standby TModerator=5 ° F TFuei=546° F 0.84881 1.01 261 -0.1618 0% Void, No xenon 46 Hot Operatingaoxe Taoderator=5 ° F TFueI=989° F 0.84501 1.00810 -0.1618 0% Void, NO xenon 4 60 Hot Operating 0 TModerator=5 F TFueI=989° F 0.84505 1.00810 -0.1617 0% Void Hot Operating 4 0 TModerator=5 46
° F TFue0=9890 F 0.80904 0.99291 -0.1852 40% Void Hot Operating 8 0 T~oder~ator=5 4 6 ° F TFueI=989° F 0.76060 0.97092 -0.2166 80% Void AREVA Inc.
C:o~.tvo~4ed Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-71 Table 2.70 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD3 BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator=6 8 ° F TFuel=68° F 0.93037 1.04805 -0.1123 0% Void, NO xenon Intermediate Taoderetor= 2 0 00 F TFueI=2 0 0 ° F 0.91834 1.03979 -0.1168 0% Void, No xenon Hot Standby TModerator=5 4 6 0 F TFueI=546° F 0.87448 1.01261 -0.1364 0% Void, NO xenon Hot OperatingNoxe TModerator=5 460 F TFueI=9 8 9 ° F 0.87053 1.00810 -0.1365 0% Void, NO xenon Hot Operating0 TModerator= 54 6 0 F TFueI=9 8 9 ° F 0.87056 1.00810 -0.1364 0% Void 4 60 Hot Operating 40 TModerator=5 F TFuei=989° F 0.83903 0.99291 -0.1550 40% Void Hot Operating 8 0 TModertor=5 46
° F TFueI=9 8 9 ° F 0.79596 0.97092 -0.1802 80% Void Table 2.71 Lattice [ ]Kinetics Parameters at BOL Kinetics Kinetics Parameter-=k~~Paaee kK1%k (Ak/k)
Dplr= kHotOperatingNoXe - kHotStandby 1.00810 1.01261 -0.0044 Dopper
=kHotStandby Moeaovd= kHot~perating4o - kHotOperating0 0.99291 1.00810 -0.0151 Modertorvia =kHotOperating0 kHotStandby - kCold 1.01 261 1.04805 -0.0338 ModeratorTemperature = kCold AREVA Inc.
Controiled Docmt t Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-72 Table 2.72 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE OEM and D120 BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k) 68 6 80 Cold TModerator= ° F mFueI= F 0.92595 1.08128 -0.1436 0% Void, No xenon Intermediate mModerator=2 0 0 0 F TFueI=2 0 0 ° F 0.91455 1.07576 -0.1499 0% Void, No xenon Hot Standby TModerator=5 46
° F T~ueZ=546 0 F 0.87375 1.06264 -0.1778 0% Void, No xenon Hot OperatingNoxe TModerator=5 4 6 ° F TFuej=9 8 9 ° F 0.87002 1.05813 -0.1778 0% Void, No xenon Hot Operating 0 mModerator=54 6 0 F TFueI=989° F 0.87009 1.05813 -0.1777 0% Void 4 60 Hot Operating 4 0 TModerator=5 F TFueI=989 0 F 0.83526 1 .04960 -0.2042 40% Void Hot Operating 80 TModerator=5 4 6
° F TFueI=989 0 F 0.78671 1 .03566 -0.2404 80% Void AREVA Inc.
Cortvoed Documlsen:t Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-73 Table 2.73 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D160 and D190 Lower Blade BaeWrh=kcontrolled " kuncontrolled kcontrolled kuncontrolled Blade kuncontrolied Worth (Ak/k)
Cold TModerator= 6 8 ° F TFueI= 6 8 ° F 0.92437 1.08128 -0.1451 0% Void, No xenon Intermediate TModerator= 2 0 0 ° F TFueI=20 00 F 0.91303 1.07576 -0.1513 0% Void, No xenon Hot Standby TModerator=5 4 60 F TFueZ=5 4 6° F 0.87212 1.06264 -0.1793 0% Void, No xenon Hot OperatingNoxe TModerator=5 46
° F Tpuei=989 0 F 0.86841 1.05813 -0.1793 0% Void, No xenon 4 60 Hot Operatingo T~oderator=5 F TFueI=989° F 0.86846 1.05813 -0.1792 0% Void 46 Hot Operating 4 0 Taoderator=5 ° F TFueI=989° F 0.83295 1.04960 -0.2064 40% Void 4 60 Hot Operating 80 TModerator=5 F TFuej=989° F 0.78333 1.03566 -0.2436 80% Void AREVA Inc.
Controlled Documen Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-74 Table 2.74 BOL Lattice [ ] Control Blade Worths at for Control Blade Type GE D190 Blade Tip kcontrolled - kuncontrolled kControlled kuncontrolled Blade Blade Worth = kuncontronled Worth
_____ ____ ____(Ak/k) 6 80 Cold TModerator= F TFueI=68° F 0.921 38 1.08128 -0.1479 0% Void, No xenon intermediate TModerator= 2 0 0 0 F TFueI=2 0 0 ° F 0.90986 1.07576 -0.1542 0% Void, No xenon 46 Hot Standby TModerator=5 ° F TFueI=546 0 F 0.86729 1.06264 -0.1838 0% Void, No xenon Hot OperatingNoxe TModerator=5 4 60 F TFuel=9 8 9 ° F 0.86362 1.05813 -0.1838 0% Void, No xenon 46 Hot Operatingo TModerator=5 ° F TFueI=989° F 0.86362 1.05813 -0.1838 0% Void 4 60 Hot Operating 4 0 TModerator=5 F TFue[=989° F 0.82641 1.04960 -0.2126 40% Void 46 Hot Operating 8 0 TModerator=5 ° F TFueI=989° F 0.77428 1.03566 -0.2524 80% Void AREVA Inc.
Contro~ed Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-75 Table 2.75 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D230 Lower Blade BaeWrh=kcontrolled -kuncontrolled kcontroiiedi kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator=6 8° F TFueI=6 8 ° F 0.91436 1.08128 -0.1544 0% Void, No xenon Intermediate TModerator=2 0 0 ° F TFuei=2 0 0 ° F 0.90261 1.07576 -0.1610 0% Void, No xenon 46 Hot Standby TModerator=5 ° F TFueI=54 6 ° F 0.85846 1.06264 -0.1921 0% Void, NO xenon Hot OperatingNoxe TModerater= 5 4 6 ° F TFU1=989° F 0.85483 1.05813 -0.1921 0% Void, NO xenon Hot Operatingo TModerator=5 4 6 0 F TFuei=989 0 F 0.85488 1.05813 -0.1921 0% Void 4 6 Hot Operating 4 0 TModerator=5 ° F TFueI=989° F 0.81586 1.04960 -0.2227 40% Void 460 Hot Operating 80 TModerator=5 F TF,*e=9 8 9 ° F 0.76127 1.03566 -0.2649 80% Void AREVA Inc.
C n~ro. d Doour~~nt Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-76 Table 2.76 Lattice [ ] Control BOL for Control Blade Type GE D230 Blade Tip Blade Worths at Bld oh kControlled - kuncontrolled kcontrolled kuncontroijed Blade
- kUncontrolled Worth (Ak/k)
Cold TModerator= 6 80 F TFu 0l=680 F 0.91772 1.08128 -0.1513 0% Void, No xenon Intermediate Taoderator=2 0 0 ° F TFueJ=200° F 0.90590 1.07576 -0.1579 0% Void, NO xenon Hot Standby TModerator=5 4 6 ° F TFueI=5460 F 0.86190 1.06264 -0.1889 0% Void, NO xenon Hot OperatingNoxe TMocjerator=546° F TFueI=9 8 9 ° F 0.85825 1.05813 -0.1889 0% Void, No xenon 46 Hot Operating 0 TModerator=5 ° F TFueC=989° F 0.85825 1.05813 -0.1889 0% Void 4 60 Hot Operating 40 TModerator=5 F Tpuei=989° F 0.82009 1.04960 -0.2187 40% Void 46 Hot Operating 8 0 TModerator=5 ° F TFueI=989 0 F 0.76685 1.03566 -0.2596 80% Void AREVA Inc.
rc~e~~cume~ ~
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-77 Table 2.77 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Bottom Segment BaeWrh=kControI~ed " kuncontrolled kcontroljed kuncontrolled Blade kuncontrolled Worth (Ak/k) 68 6 Cold TModerator= ° F TFueI= 8° F 0.92783 1.08128 -0.1419 0% Void, No xenon lntermediate TModerator=2 0 0 0 F TFuel=20 0 ° F 0.91671 1.07576 -0.1479 0% Void, No xenon 4
Hot Standby Tuoderator=5 6° F TFueI=546 0 F 0.87604 1.06264 -0.1756 0% Void, No xenon Hot OperatingNoxe TModerator=5 4 60 F TFuej=9 8 9 0 F 0.87233 1.05813 -0.1756 0% Void, No xenon 46 9890 Hot Operating 0 TModerator=5 ° F TF,,eI F 0.87238 1.05813 -0.1756 0% Void Hot Operating 4 0 Taederator=5 4 6
° F T~ueI=989 0 F 0.83721 1.04960 -0.2024 40% Void Hot Operating 80 TModerator=5 4 6 ° F TFue=989° F 0.78795 1 .03566 -0.2392 80% Void AREVA Inc.
Nuclear Fuel Design Report AN P-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-78 Table 2.78 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Main Segment BaeWrh=kcontrolled " kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator= 6 8 ° F TFueQ=68° F 0.92083 1.08128 -0.1484 0% Void, No xenon Intermediate TModeretor= 2 0 00 F TFuel=200° F 0.90945 1.07576 -0.1546 0% Void, No xenon Hot Standby TModeretor=5 4 6 ° F Tiuej=546° F 0.86694 1.06264 -0.1842 0% Void, NO xenon 46 89 Hot OperatingNoxe TModeretor=5 ° F TF.ue=9 °F 0.86328 1.05813 -0.1842 0% Void, No xenon 46 Hot Operatingo TModermtor=5 ° F TFueI=989° F 0.86333 1.05813 -0.1841 0% Void 4 60 Hot Operating 40 TModerator=5 F TFueI=989° F 0.82575 1.04960 -0.2133 40% Void 46 Hot Operating 80 TModeretor=5 ° F TFuej=9 8 9 ° F 0.77318 1.03566 -0.2534 80% Void AREVA Inc.
'~nro~;~., DoeLmert Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 10XM Fuel Page 2-79 Table 2.79 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Main BaeWrh=kcontrolIed - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth
____ ____ ____(Ak/k) 80 Cold mModerator=6 F TFueI=68° F 0.92189 1.08128 -0.1474 0% Void, NO xenon Intermediate TModerator=2 0 0 ° F TFueI=200° F 0.91070 1.07576 -0.1534 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFuei=546° F 0.86900 1.06264 -0.1822 0% Void, No xenon 4 60 Hot OperatingNoxe TMocjerator=5 F TFueI=989° F 0.86533 1.05813 -0.1822 0% Void, No xenon 46 Hot Operating 0 TModerator=5 ° F TFue1=989° F 0.86540 1.05813 -0.1821 0% Void Hot Operating 4 0 TModerator=5 460 F TFueI=989 0 F 0.82886 1 .04960 -0.2103 40% Void 46 Hot Operating 80 TModerator=5 ° F TFueI=989° F 0.77722 1.03566 -0.2495 80% Void_____
AREVA Inc.
Con trolled Doc urne Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-80 Table 2.80 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Tip BaeWrh=kcontrolled " kuncontronled koontrolled kuncontrolied Blade kuncontrolled Worth
_____ ____ ____(Ak/k)
Cold TModerator= 6 8 ° F TFueI=68° F 0.941 70 1.08128 -0.1291 0% Void, No xenon_____
Intermediate Taoderator=
2 00
° F TFueI=2 0 0 0 F 0.93133 1.07576 -0.1343 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFuel=546° F 0.89550 1 .06264 -0.1573 0% Void, No xenon 4
Hot Operatingaoxe T~oderator=5 6° F TFUeI=989 0 F 0.89166 1.05813 -0.1573 0% Void, No xenon 46 Hot Operating 0 TModerator=5 ° F TFueI=989° F 0.89166 1.05813 -0.1573 0% Void 46 Hot Operating 4 0 TModerator=5 ° F TFueI=989° F 0.86150 1.04960 -0.1792 40% Void 46 Hot Operating 8 0 mModerator=5 ° F TFueI=989° F 0.81883 1.03566 -0.2094 80% Void AREVA Inc.
Contro~ed Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-81 Table 2.81 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Tip BaeWrh=kcontrolled "kuncontrolied kcontrolled kuncontrolied Blade kuncontrolled Worth (Ak/k) 80 Cold mModerator= 6 F TFueI=68° F 0.92048 1.08128 -0.1487 0% Void, NO xenon Intermediate Taoderator= 2 0 0 ° F TFueI=200° F 0.90905 1.07576 -0.1550 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFueI=546 0 F 0.86634 1.06264 -0.1847 0% Void, No xenon 4 60 Hot OperatingNoxe TModeretor=5 F TFueI=989 0 F 0.86267 1.05813 -0.1847 0% Void, No xenon Hot Operating0 TModerator=5 4 6
° F TFueI=989 0 F 0.86275 1.05813 -0.1847 0% Void Hot Operating 4 0 TModerator=5 4 60 F TFueI=989 0 F 0.825 12 1.04960 -0.2139 40% Void Hot Operating 80 TModerator=5 4 6
° F TFU 6 I=9 89° F 0.77186 1.03566 -0.2547 80% Void ARE VA Inc.
Contro~ed Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-82 Table 2.82 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Main kcontrolled - kuncontrolled kcontrolred kuncontrolled Blade Blade Worth = kuncontrolled Worth
_______ (Ak/k)
Cold TModerator=6 8 0 F TFueI=68° F 0.91899 1.08128 -0.1501 0% Void, No xenon Intermediate TModerator=2 0 0 0 F TFuel=2000 F 0.90751 1.07576 -0.1564 0% Void, No xenon 46 Hot Standby TModerator=5 ° F TFueZ=546° F 0.86437 1.06264 -0.1866 0% Void, No xenon 4 60 Hot OperatingNoxe TModerator=5 F TFuej=989° F 0.86072 1.05813 -0.1866 0% Void, NO xenon 4 60 Hot Operating 0 mModerator=5 F mFuei=9890 F 0.86079 1.05813 -0.1865 0% Void 4 60 Hot Operating 4 0 TModerator=5 F TFueI=9890 F 0.82261 1.04960 -0.2163 40% Void Hot Operating 80 TModerator=5 4 6° F TFueI=9 8 9 0 F 0.76855 1.03566 -0.2579 80% Void AREVA Inc.
.(4 ......... [.,., * ! * ' *'*.O,*'*
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-83 Table 2.83 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD2 BaeWrh kcontroljed "kuncontrolled kcontrolled kUncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator= 6 8 ° F TFUel= 6 80 F 0.94052 1.08128 -0.1302 0% Void, No xenon Intermediate TModerator=2 0 0 0 F TFuel= 2 000 F 0.92990 1 .07576 -0.1356 0% Void, No xenon 46 Hot Standby mModerator=5 ° F TFueI=546° F 0.89204 1.06264 -0.1605 0% Void, NO xenon 46 Hot Operatingaoxe TModerator=5 ° F TFuei=989° F 0.88823 1.05813 -0.1606 0% Void, NO xenon 4 60 Hot Operating 0 Taoderator=5 F TF,,e=989° F 0.88828 1.05813 -0.1605 0% Void 46 Hot Operating 40 TModerator=5 ° F TFueI=989 0 F 0.85596 1.04960 -0.1845 40% Void 4 60 Hot Operating 8 0 TModerator=5 F TFueI=989° F 0.81002 1.03566 -0.2179 80% Void AREVA Inc.
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-84 Table 2.84 Lattice [
BOL for Control Blade Type GE Marathon Ultra HD3
] Control Blade Worths at BaeWrh=kcontrolled " kuncontrolled kcontrolied kuncontrolled Blade kuncontrolled Worth (AkJk)
Cold TModerator=6 8 ° F TFueI=680 F 0.96199 1.08128 -0.1103 0% Void, No xenon Intermediate TModerator= 2 0 0 ° F TFu 8 12000 F 0.95214 1.07576 -0.1149 0% Void, No xenon Hot Standby TModerator= 5 4 6 ° F TFueI=546° F 0.91 931 1.06264 -0.1349 0% Void, No xenon Hot Operatingaoxe T~oderator=5 4 6 ° F TFueI=9 8 9 0 F 0.91534 1.05813 -0.1349 0% Void, No xenon Hot Operatingo TModerator= 5 4 6 0 F TFueI=989 0 F 0.91 538 1.05813 -0.1349 0% Void Hot Operating 4 0 TModerator= 5 4 6 ° F TFue0=989 0 F 0.88824 1.04960 -0.1537 40% Void Hot Operating 860 TModerator=5 4 60 F TFueI=989 0 F 0.84889 1.03566 -0.1803 80% Void Table 2.85 Lattice [ ] Kinetics Parameters at BOL Kinetics Kinetics Parameter =ka-kPrmer k*k k* (Ak/k)
Dplr= kHotOperatingNoXe - kHotStandby 1.05813 1.06264 -0.0042 kHotStandby MdatrOd= kHotOperating4o - kt-otOperatingO 1. 04960 1. 05813 -0. 0081 Modertorvid =kHotOperating0 kHotStandby " kcold 1.06264 1.08128 -0.01 72 ModeratorTemperature = kCold AREVA Inc.
ControiledDouei Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 10XM Fuel Page 2-85 Table 2.86 BOL Lattice [ ] Control Blade Worths at for Control Blade Type GE OEM and D120
_ kcontrolled " kuncontrolled kcontrojled kuncontrojledi Blade Blade Worth = kuncontrolled Worth (Ak/k)
Cold mModerator= 6 8 ° F TFu 6 1=68° F 0.95930 1.11765 -0.1417 0% Void, No xenon Intermed iate mModerator= 2 0 0 0 F TFue1=200 0 F 0.94431 1.10727 -0.1472 0% Void, No xenon Hot Standby TModerator= 5 4 6 0 F Tiuei=546° F 0.88618 1.07039 -0.1721 0% Void, No xenon Hot OperatingNox 8 TModerator=5 46
° F TFueI=9 3 0° F 0.88224 1.06567 -0.1721 0% Void, No xenon Hot Operatingo TModerator=5 4 6 0 F TFueI=930° F 0.88231 1.06567 -0.1721 0% Void 460 Hot Operating 4 0 mModerator=5 F TFueI=930° F 0.84000 1.04412 -0.1955 40% Void 46 Hot Operating 8o TModerator=5 ° F TFueI=930° F 0.78885 1.01 855 -0.2255 80% Void AREVA Inc.
Contrlo led Documsent Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-86 Table 2.87 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D160 and D190 Lower Blade kcontronled - kuncontrolled kcontrolled kuncontrolledj Blade BaeWrh= kuncontrolled Worth (Ak/k) 6 80 Cold TModerator= FTpuei=68° F 0.95738 1.11765 -0.1434 0% Void, NO xenon Intermediate TModerator= 2 0 0
° F TFueI=2000 F 0.94245 1.10727 -0.1489 0% Void, No xenon Hot Standby TModerator= 5 4 6 ° F Tpuel=546° F 0.88420 1.07039 -0.1739 0% Void, No xenon Hot OperatingNoxe mModerator=5 4 60 F TFueI=9 3 0 ° F 0.88028 1.06567 -0.1740 0% Void, No xenon Hot Operating 0 TModerator=5 4 6 0 F TFueI=930 0 F 0.88033 1.06567 -0.1739 0% Void 4 60 Hot Operating 40 TModerator=5 F TFueI=930° F 0.83741 1.04412 -0.1980 40% Void 46 Hot Operating 80 TModerator=5 ° F TFue= 9 3O0° F 0.78533 1.0 1855 -0.2290
!80% Void AREVA Inc.
Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-87 Table 2.88 BOL Lattice [ ] Control Blade Worths at for Control Blade Type GE D190 Blade Tip BaeWrh=kcontrolled - kunicontrolled kcontrolled kunoontroiied Blade kuncontrolled Worth (Ak/k)
Cold TModerator= 6 8 0 F TFuei=68 0 F 0.95421 1.11765 -0.1462 0% Void, No xenon Intermediate TModerator=2 0 0 0 F TFueI=2 0 0 ° F 0.93902 1.10727 -0.1520 0% Void, No xenon 46 46 Hot Standby TModerator=5 ° F TFueI=5 ° F 0.87902 1.07039 -0.1788 0% Void, No xenon 4 6 Hot OperatingNoxe TModerator=5 ° F TFueI=930° F 0.87514 1.06567 -0.1788 0% Void, No xenon Hot Operatingo TModerator=5 46
° F TFueI=93 0° F 0.87514 1 .06567 -0.1788 0% Void 46 Hot Operating 40 TModerator=5 ° F TFueI=930° F 0.83069 1.04412 -0.2044 40% Void 46 Hot Operating 80j mModerator=5 ° F TFuej=930° F 0.77664 1.01855 -0.2375 80% Void AREVA Inc.
=Ontro, ed Doocumhent Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-88 Table 2.89 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0230 Lower Blade BaeWrh=kcontro~led - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth
_______________(Ak/k)
Cold TModerator= 6 8 0 F TFueI=68 0 F 0.94652 1.11765 -0.1531 0% Void, NO xenon Intermediate TModerator=2 00
° F TF,,ei=2 0 0 ° F 0.93117 1.10727 -0.1590 0% Void, No xenon Hot Standby TMederator=5 46
° F TFue1=5 4 6 ° F 0.86996 1.07039 -0.1872 0% Void, No xenon Hot OperatingNoxe TModerator=5 4 6 ° F T~ueI=930° F 0.86613 1.06567 -0.1872 0% Void, NO xenon Hot Operating 0 TModerator=5 46
° F TFueI=9300 F 0.86619 1.06567 -0.1872 0% Void Hot Operating 4 0 TModerator=5 4 6 0 F TFueI=9300 F 0.82026 1.04412 -0.2144 40% Void Hot Operating 80 TModerator=5 46
° F TFueI=9 3 0° F 0.76429 1.01855 -0.2496 80% Void AREVA Inc.
Controiecd Doe urnqen Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-89 Table 2.90 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D230 Blade Tip BaeWrh-kcontrolled - kuncontrolled kcontroiiedj kuncontrojied Blade kuncontrolled Worth (AkJk)
Cold TModerator= 680 F TFuei=68 0 F 0.95023 1.11765 -0.1498 0% Void, No xenon Intermediate TModerator=2 0 0 ° F TF,,e=200 0 F 0.93477 1.10727 -0.1558 0% Void, NO xenon 4 60 Hot Standby TModerator=5 F TFueI=546° F 0.87352 1.07039 -0.1839 0% Void, NO xenon 46 Hot OperatingNoxe TModerator=5 ° F TFueI=930° F 0.86966 1.06567 -0.1839 0% Void, No xenon Hot Operating 0 TModerator=5 46
° F TFueI=930 0 F 0.86966 1 .06567 -0.1839 0% Void Hot Operating 4 0 TModerator=5 4 60 F TFuej=93O0 F 0.82450 1.04412 -0.2103 40% Void 46 Hot Operating 8o T~oderator=5 ° F TFueI=930° F 0.76974 1 .01855 -0.2443 80% Void AREVA Inc.
Con toiled Docuenti Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-90 Table 2.91 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Bottom Segment kcontrolled - kuncontrolled koontrolled kuncontrolled Blade BaeWrh= kuncontrolled Worth (Aklk)
Cold TModerator=6 80 F TF,,ej=6 80 F 0.96076 1.11765 -0.1404 0% Void, No xenon Intermediate TModerator=2 0 0 0 F TFuel= 2O00 F 0.94591 1.10727 -0.1457 0% Void, No xenon 4 6 Hot Standby T]Moderator-'5 ° F TFueI=546° F 0.88736 1.07039 -0.1710 0% Void, No xenon 4 60 Hot OperatingNoxe TModerator=5 F TFue1=930° F 0.88343 1.06567 -0.1710 0% Void, NO xenon 46 Hot Operatingo TModerator=5 ° F TFueI=9 3 O0 F 0.88349 1.06567 -0.1709 0% Void 46 Hot Operating 4 o TModerator=5 ° F TFUeI=930° F 0.84068 1.04412 -0.1948 40% Void 460 3 Hot Operating 8o mModerator=5 F TFu 8 1=9 0° F 0.78887 1.01855 -0.2255 80% Void AREVA Inc.
Controlled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-91 Table 2.92 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Main Segment BaeWrh=kControlled - kUncontrolled kcontroi led kUncontroilld Blade kuncontrolted Worth
____ ____ ____(Ak/k)
Cold TModerator= 6 8 ° F TFueI=68° F 0.95378 1.11765 -0.1466 0% Void, NO xenon Intermediate Taoderator=2 0 0
° F TFuel=200° F 0.93874 1.10727 -0.1522 0% Void, No xenon 46 Hot Standby TModerator=5 ° F TFuel=546° F 0.87867 '1.07039 -0.1791 0% Void, No xenon 46 Hot OperatingNoxe TModerator=5 ° F TFueI=930° F 0.87479 1.06567 -0.1791 0% Void, No xenon Hot Operating 0 TModerator= 5 4 6 ° F TFueI=9300 F 0.87485 1.06567 -0.1791 0% Void 46 Hot Operating 40 TModerator=5 ° F TFueI=93O0 F 0.82997 1.04412 -0.2051 40% Void 460 Hot Operating 80 TModerator=5 F TFueI=930° F 0.77538 1 .01855 -0.2387 80% Void AREVA Inc.
Contro~e~. D wmeK Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-92 Table 2.93 Lattice [ ] Control BOL for Control Blade Type CR82M1 and CR82B Blade Main Blade Worths at BaeWrh=kcontrolled " kuncontrolled kcontrojled kuncontrolled Blade kuncontrolled Worth
_______(Ak/k) 6 80 Cold TModerator= F TFu 0 1=68° F 0.95332 1.11765 -0.1470 0% Void, NO xenon Intermediate TModerator= 2 0 0 ° F TFueI200° F 0.93834 1.10727 -0.1526 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFuel=546 0 F 0.87880 1.07039 -0.1790 0% Void, No xenon Hot OperatingNoxO TMederator=5 4 6
° F TFueI=9 3 O0 F 0.87492 1.06567 -0.1790 0% Void, No xenon Hot Operatingo TModerator=5 4 6 ° F TFueI=93O0 F 0.87500 1.06567 -0.1789 0% Void 46 Hot Operating 40 TModerater=5 ° F TFueI=930° F 0.83098 1.04412 -0.2041 40% Void 46 Hot Operating 80 TModerator=5 ° F TFueI=930° F 0.77737 1.01855 -0.2368 80% Void ARE VA Inc.
F*" .... " " I" * * ,*'* r.* "
Nuclear Fuel Design Report AN P-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-93 Table 2.94 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR826 Blade Tip BaeWrh=kcontrolled " kUncontrolled kcontrolled kuncontrolled Blade kuncontronled Worth (Ak/k)
Cold TModerator= 6 8 0 F TFuet=68° F 0.97503 1.11765 -0.1276 0% Void, No xenon Intermediate TModeretor=2 0 0 ° F TFUeI=20 0 ° F 0.96078 1.10727 -0.1323 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFueI=546 0 F 0.90632 1.07039 -0.1533 0% Void, No xenon 4
Hot OperatingNoxe TModerator=5 6° F TFueI=930° F 0.90227 1.06567 -0.1533 0% Void, NO xenon 46 Hot Operating0 TModerator=5 ° F TFueI=930° F 0. 90227 1.06567 -0.1533 0% Void 46 Hot Operating 40 TModerator=5 ° F TFue!=930° F 0.86357 1.04412 -0.1729 40% Void 4 60 Hot Operating 8 0 TModerator=5 F TFueI=930° F 0.81 687 1.01855 -0.1980 80% Void AREVA Inc.
C ont , .d .....en Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-94 Table 2.95 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Tip BaeWrh=kcontrolled "kuncontrolled kcontrolled kuncontrolled Blade kuncontrolied Worth (Aklk)
Cold TModerator= 6 8 0 F TFueI=6 80 F 0.95248 1.11765 -0.1478 0% Void, No xenon Intermediate TModerator= 2 0 0 ° F TFue*= 2O 00 F 0.93737 1.10727 -0.1534 0% Void, No xenon Hot Standby TModerator= 5 4 6 0 F TFueI=54 6 ° F 0.87709 1.07039 -0.1806 0% Void, No xenon 46 Hot Operatingaoxe TModerator=5 ° F TFuet=930° F 0.87322 1.06567 -0.1806 0% Void, No xenon Hot Operating0 Taoderator=5 4 6 ° F TFueI=930 0 F 0.87330 1.06567 -0.1805 4 6 Hot Operating 40 Taoderator=5 ° F TFuej=930° F 0.82828 1.04412 -0.2067 4 60 0 Hot Operating 80 TModerator=5 F TF,, 0 1930 F 0.77306 1.01855 -0.2410 80% Void AREVA Inc.
oor~tr~iv~d Doc~u ment Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-95 Table 2.96 Lattice [ ] Control BOL for Control Blade Type CR99 Blade Main Blade Worths at BaeWrh=kcontroijed " kuncontrolled kcontroijedi kuncontrolled Blade kuncontrolled Worth
_______(Ak/k) 80 0 Cold TModerator=6 F TFueI=68 F 0.95092 1.11765 -0.1492 0% Void, No xenon Intermediate TModerator=2 0 0 0 F TF,,eI=2 00 ° F 0.93578 1 .10727 -0.1549 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFueI=546° F 0.87510 1.07039 -0.1825 0% Void, No xenon Hot OperatingNoxe TModerator= 5 4 6 ° F TFueI=9 3 0 ° F 0.87124 1.06567 -0.1825 0% Void, NO xenon Hot Operating 0 TModerator=5 4 6 ° F TFueI=9 3 0° F 0.87132 1.06567 -0.1824 0% Void Hot Operating 4 0 TModerator=5 4 6
° F TFueI=930° F 0.82584 1.04412 -0.2091 40% Void 46 Hot Operating so TModerator=5 ° F TF,,e=9 3 O0 F 0.76997 1.01855 -0.2440 80% Void AREVA Inc.
ContrcI~ed Documani Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-96 Table 2.97 Lattice [ ] Control BOL for Control Blade Type GE Marathon Ultra HD2 Blade Worths at Bld oh=kcontrolled - kuncontrolled koontrolled kuncontrolled Blade kuncontrolled Worth
_______ (Ak/k) 68 Cold TModerator= ° F TFueI=68° F 0.97457 1.11765 -0.1280 0% Void, No xenon Intermediate Tuoderator=2 0 0 ° F TFueI=2 0 0 ° F 0.96017 1.10727 -0.1328 0% Void, No xenon Hot Standby TModerator=5 46
° F Tpuei=546 0 F 0.90403 1.07039 -0.1554 0% Void, No xenon 4 60 Hot Operatingaoxe TModerator=5 F mFueI=930° F 0.90000 1 .06567 -0.1555 0% Void, No xenon Hot Operating 0 TModerator=5 4 60 F TFueI=93O0 F 0.90006 1.06567 -0.1554 46 Hot Operating 40 Taoderator=5 ° F TFueI=930° F 0.85943 1.04412 -0.1769 46 Hot Operating 8 0 Tuodeator=5 ° F TFueI=930° F 0.80982 1.01855 -0.2049 80% Void AREVA Inc.
~~oUO L oA*mi.
_,k Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page 2-97 Table 2.98 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD3 BaeWrh=kcontrolled " kuncontrolled kcontroiledi kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator=6 8 ° F TFuej=6 80 F 0.99721 1.11765 -0.1078 0% Void, No xenon Intermediate TModerator=2 0 0 ° F TFueI=200° F 0.98350 1.10727 -0.1118 0% Void, No xenon Hot Standby Taoderator=5 460 F TFuel=54 6 ° F 0.93145 1.07039 -0.1298 0% Void, No xenon Hot Operatingaoxe Taodjerator=5 46
° F TFuej=93 0 ° F 0.92726 1.06567 -0.1299 0% Void, No xenon Hot Operating 0 iTModereor=5 46
° F TFueJ=9 3O0 F 0.92730 1.06567 -0.1298 0% Void Hot Operating 40 Taoderator=5 46
° F TFueI=93 0 ° F 0.89072 1.04412 -0.1469 40% Void 46 Hot Operating 80 TModerator=5 ° F TF,,I=9 3 O0 F 0.84579 1.01 855 -0.1696 80% Void Table 2.99 Lattice [ ] Kinetics Parameters at BOL Kinetics Kinetics Parameter ka-Pamer kKtk (Ak/k)
Dplr= kHotOperatingNoXe - kHotStandby 1.06567 1.07039 -0.0044 Dopper
=kHotStandby Mertrld= kt-otOperating40 - kHotOperatfng0 1.04412 1.06567 -0.0202 Modertorvid =kHotOperating0 Moeaormeue- kHotStandby - kcOld 1.07039 1.11765 -0.0423 Modeatorempratue = kcold AREVA Inc.
Contr3Ce DoJ m Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-98 Table 2.100 Lattice [
at BOL for Control Blade Type GE OEM and D120
] Control Blade Worths BaeWrh=kcontrolled " kuncontroijed kControljed kuncontrolled Blade kuncontrolled Worth (Ak/k) 6 80 0 Cold TModerator= F TFueI=68 F 0.89052 1,05078 -0.1525 0% Void, NO xenon Intermediate mModerator= 2 0 0 ° F TFueI=2 0 0 ° F 0.87612 1.04104 -0.1584 0% Void, No xenon 460 Hot Standby TModerator=5 F TFueI=546 0 F 0.82362 1.00975 -0.1843 0% Void, NO xenon Hot Operatingaoxe Taoderator=5 46
° F TFueI=9 8 9 0 F 0.81975 1.00503 -0.1844 0% Void, No xenon 46 Hot Operating 0 TModerator=5 ° F TFueI=989° F 0.81982 1 .00503 -0.1843 0% Void 4 60 Hot Operating 40 Taoderator=5 F TFue0=989° F 0.78126 0.98706 -0.2085 40% Void 4 60 Hot Operating 80 TModerator=5 F TFueI=989° F 0.73345 0.96512 -0.2400 80% Void AREVA Inc.
C;ontvo~ed Docu rv~'
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-99 Table 2.101 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D160 and D190 Lower Blade BaeWrh=kcontrolled " kuncontrofled koontroijecd kuncontrolled Blade kuncontrolieci Worth (Ak/k)
Cold TModerator=6 8 ° F TFueI=6 8 ° F 0.88874 1.05078 -0.1542 0% Void, No xenon Intermediate TModerator=2 0 0 0 F TFueI=20 0 ° F 0.87440 1.04104 -0.1601 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFueI=546° F 0.82181 1.00975 -0.1861 0% Void, No xenon Hot Operatingaoxe Tuoderator= 54 6 ° F TFuei=989 0 F 0.81796 1.00503 -0.1861 0% Void, No xenon 46 Hot Operatingo TModerator=5 ° F TF,,e=989° F 0.81 801 1.00503 -0.1861 0% Void 46 Hot Operating 40 TModerator=5 ° F TFueI=989° F 0.77887 0.98706 -0.2109 40% Void 4 60 Hot Operating 80 TModerator=5 F TFueI=989° F 0.73016 0.96512 -0.2434 80% Void AREVA Inc.
Co triLJ Do~L~eK Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-100 Table 2.102 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D190 Blade Tip BaeW rh- kcontrolled - kuncontrolled kcontrolledi kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator=6 8 ° F TFueI=68° F 0.88553 1.05078 -0.1573 0% Void, No xenon Intermediate TModerator= 2 0 0 ° F TFuei=2 0 0 ° F 0.87096 1.04104 -0.1634 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFueI=546 0 F 0.81675 1.00975 -0.1911 0% Void, No xenon 4 60 Hot OperatingNoxe TModerator=5 F TFueI=989 0 F 0.81294 1.00503 -0.1911 0% Void, No xenon Hot Operating 0 TModerator=5 460 F TFuel=989 0 F 0.81294 1.00503 -0.1911 0% Void 46 Hot Operating 4 0 TModerator=5 ° F TFueI=989° F 0.77232 0.98706 -0.2176 40% Void Hot Operating 8o TModerator=5 460 F TFuel=989 0 F 0.72 164 0.96512 -0.2523 80% Void AREVA Inc.
Controcle.doo m Nuclear Fuel Design Report AN P-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-101 Table 2.103 Lattice [ ] Control Blade at BOL for Control Blade Type GE D230 Lower Blade Worths BaeWrh=kcontroljed - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator=6 8° F TFueI=68 0 F 0.87798 1.05078 -0.1645 0% Void, No xenon Intermediate Taoderator=2 0 0 ° F TFueI=20 0 0 F 0.86323 1.04104 -0.1708 0% Void, No xenon Hot Standby TModeratOr=5 4 6 0 F T~ue1=546° F 0.80777 1.00975 -0.2000 0% Void, NO xenon 4 60 Hot OperatingNox0 TModerator=5 F TFueI=989° F 0.80401 1 .00503 -0.2000 0% Void, No xenon 46 Hot Operatingo TModerator=5 ° F TFueI=989 0 F 0.80406 1 .00503 -0.2000 0% Void Hot Operating 40 TModerator=5 4 60 F T~uel=989 0 F 0.76197 0.98706 -0.2280 40% Void 4 60 Hot Operating 80 TModerator=5 F TFuej=989° F 0.70936 0.96512 -0.2650 80% Void AREVA Inc.
Coto ©oott eTtOY Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page 2-102 Table 2.104 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D230 Blade Tip BaeWrh=kcontrolled - kuncontrolled kcontrot led kunoontrolled Blade kuncontrolled Worth (Ak/k) 68 0 Cold TModerator= ° F TFuel=68 F 0.88156 1.05078 -0.1610 0% Void, No xenon Intermediate TModerater=2 0 00 F TFueI=200 0 F 0.86671 1.04104 -0.1675 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFUe=5460 F 0.81125 1.00975 -0.1966 0% Void, No xenon Hot OperatingNoxe TModerator=5 4 6 ° F TFueI=989° F 0.80746 1.00503 -0.1966 0% Void, No xenon Hot Operatingo TModerator=5 4 6 0 F TFueI=989° F 0.80746 1.00503 -0.1966 0% Void Hot Operating 40 TModerator=5 4 6 0 F TFue1=989° F 0.76610 0.98706 -0.2239 40% Void 4 60 Hot Operating 80 TModeretor=5 F TFue1=989° F 0.71466 0.96512 -0.2595 80% Void AREVA Inc.
LJ~.)YU~ ~zrv~
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-103 Table 2.105 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Bottom Segment BaeWrh=kcontrolled - kuncontrofled kcontroljod kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator=6 8
° F TFueI=68 0 F 0.89163 1.05078 -0.1515 0% Void, No xenon Intermediate TModerator=2 0 0 ° F TFuel=200° F 0.87742 1.04104 -0.1572 0% Void, No xenon Hot Standby TModerator= 5 4 6 0 F TFueI=546 0 F 0.82471 1.00975 -0.1832 0% Void, No xenon 46 9 89 Hot OperatingNoxe Taoderator=5 ° F TFueZ= °F 0.82086 1.00503 -0.1832 0% Void, No xenon Hot Operating 0 TModerator=54 6 0 F TFueI=98 9 ° F 0.82091 1.00503 -0.1832 0% Void 4 60 Hot Operating 4 0 TModerator=5 F TFuej=989° F 0.78190 0.98706 -0.2079 40% Void 4 60 Hot Operating 80 TModerator=5 F TFue1=989° F 0.73347 0.96512 -0.2400 80% Void AREVA Inc.
Contro~ed Docun~en~
Nuclear Fuel Design Report AN P-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-104 Table 2.106 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Main Segment BaeWrh=kcontrolled "kuncontrolled kcontrolled kuncontrolled Blade kuncontroi led Worth (Akdk)
Cold TModerator=6 8 0 F TFuel= 6 8 ° F 0.88489 1.05078 -0.1579 0% Void, No xenon 0 00 TModerator=2 00 Intermediate ° F TFuel=2 F 0.87049 1.04104 -0.1638 0% Void, No xenon Hot Standby TModerator=5 4 6 ° F TFueI=54 6 ° F 0.81630 1.00975 -0.1916 0% Void, No xenon 4 60 Hot OperatingNoxe TModerator=5 F TFuel=989° F 0.81250 1.00503 -0.1916 0% Void, No xenon 46 Hot Operatingo TMederator=5 ° F TFue1=989° F 0.81256 1.00503 -0.1915 0% Void Hot Operating 40 TModerator=5 4 6 0 F TFue1=989° F 0.77152 0.98706 -0.2184 40% Void 4 60 Hot Operating 8a0 TModerator=5 F TFueI=989 0 F 0.72032 0.96512 -0.2536 80% Void AREVA Inc.
Q<ontrA! ,jlaimerd Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-105 Table 2.107 Lattice [ ] Control Blade at BOL for Control Blade Type CR82M1 and CR82B Blade Main Worths BaeWrh=kcontrolled - kujncontrolled koontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator=6 8 ° F TFueI=6 8 ° F 0.88422 1.05078 -0.1585 0% Void, NO xenon Intermediate TModerator= 2 0 00 F TFueI=2 0 0 ° F 0.86987 1.04104 -0.1644 0% Void, No xenon Hot Standby TModerator=5 4 60 F TFuet=54 6 ° F 0.81610 1.00975 -0.1918 0% Void, No xenon Hot OperatingaoxC T~oderator= 5 4 60 F TFueI=9 8 9 ° F 0.81229 1.00503 -0.1918 0% Void, No xenon Hot Operatingo TModerator=5 4 60 F TFueI=9 8 90 F 0.81237 1.00503 -0.1917 0% Void 46 Hot Operating 40 TModerator=5 ° F TFueI=9 8 9° F 0.77216 0.98706 -0.2177 40% Void 460 89 Hot Operating 8 0o TModerator=5 F mFuei=9 ° F 0.72 195 0.96512 -0.2520 80% Void AREVA Inc.
ied Docurnent Nuclear Fuel Unit Design Report ANP-3294NP Quad Cities 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-106 Table 2.108 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Tip BaeWrh=kcontrolled " kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold mModerator= 6 8 0 F TFuel= 6 8 0 F 0.90560 1.05078 -0.1382 0% Void, NO xenon Intermediate TModerator= 2 0 0 0 F TFueI=200° F 0.89197 1.04104 -0.1432 0% Void, No xenon Hot Standby TModerator=5 4 6 0 F TFue!=546° F 0.84328 1.00975 -0.1649 0% Void, NO xenon 46 Hot OperatingNoxe TModerator=5 ° F TFueI=9 8 9 ° F 0.83930 1.00503 -0.1649 0% Void, NO xenon 4 60 89 Hot Operating 0 TModerator=5 F TFueI=9 ° F 0.83930 1.00503 -0.1649 0% Void Hot Operating 40 TModerator=5 4 60 F TFueC=989 0 F 0.80432 0.98706 -0.1851 40% Void 4 60 Hot Operating 80 TModerator=5 F TFue1=989° F 0.76105 0.96512 -0.2114 80% Void AREVA Inc.
CdjflUL~d nr~y~r~v~
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-107 Table 2.109 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Tip BaeWrh=kControlIed " kuncontrolled kcontrolled kuncontroried Blade kuncontrolled Worth (Akdk)
Cold TModerator=6 8 ° F TFueI=6 8° F 0.88386 1.05078 -0.1588 0% Void, No xenon TModerator= 2 0 0 Intermediate ° F TFueI=200° F 0.86937 1.04104 -0.1649 0% Void, NO xenon 46 Hot Standby TModerator=5 ° F TFueI=546° F 0.81488 1.00975 -0.1930 0% Void, No xenon 46 8 90 Hot OperatingNoxe TMocterator=5 ° F TFue1=9 F 0.81108 1.00503 -0.1930 0% Void, NO xenon Hot Operating 0 TModerater=5 4 60 F TFueI=9 8 9 ° F 0.81115 1.00503 -0.1929 0% Void 46 Hot Operating 40 TModerator=5 ° F TFueI=989° F 0.77000 0.98706 -0.2199 40% Void 46 Hot Operating 80 TModerator=5 ° FTpuei=989° F 0.71821 0.96512 -0.2558 80% Void AREVA Inc.
ConltruiledDcurri Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-108 Table 2.110 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Main BaeWrh=kcontrolled " kuncontrolled kcontrojled kuncontrolled Blade kuncontrolled Worth (Ak/k) 6 80 0 Cold TModerator= F TFueI=68 F 0.88231 1.05078 -0.1603 0% Void, No xenon Intermediate TModerator=2 0 00 F Tpuei=200° F 0.86779 1.04104 -0.1664 0% Void, No xenon Hot Standby Tuoderator=5 46
° F TF,,e=5460 F 0.81292 1.00975 -0.1949 0% Void, No xenon Hot Operatingaoxe TModerator= 5 4 60 F TFueI=989° F 0.80914 1.00503 -0.1949 0% Void, No xenon 4 60 9 890 Hot Operating 0 Taoderator=5 F TFueF= F 0.80922 1.00503 -0.1948 0% Void 46 Hot Operating 40 Taoderator=5 ° F TFruej=989° F 0.76760 0.98706 -0.2223 40% Void 46 Hot Operating 8 0 Tuoderator=5 ° F TFueI=9 8 9 ° F 0.71517 0.96512 -0.2590 80% Void AREVA Inc.
Co~ (rc2~ed Docuinen~
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM_10XM Fuel Page 2-109 Table 2.111 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD2 Bld vrh= kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade kuncontroIled Worth (Ak/k) mModerator= 6 8 Cold ° F TFueI=68° F 0.90569 1.05078 -0.1381 0% Void, No xenon Intermediate TModerator= 2 0 0 ° F T~uei=200° F 0.89190 1.04104 -0.1433 0% Void, No xenon Hot Standby TModerator= 5 4 6 0 F TFueI=5 4 6 ° F 0.84159 1.00975 -0.1665 0% Void, No xenon Hot OperatingNoxe TModerator= 5 4 60 F TFueI=98 9 ° F 0.83763 1 .00503 -0.1666 0% Void, NO xenon Hot Operating 0 TModeratoj=5 4 6 0 F TFue1=989° F 0.83768 1.00503 -0.1665 0% Void Hot Operating 4 0 TModerator=5 4 60 F TFueI=9 8 9 ° F 0.80089 0.98706 -0.1886 40% Void Hot Operating 8 0 TModerator=5 46
° F TFeI=9 8 9 ° F 0.75473 0.96512 -0.21 80 80% Void AREVA Inc.
~Dontro~ed Docurneiit Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-110 Table 2.112 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD3 BaeWrh=kcontrolled - kuncontrouled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator= 68
° F TFuej=680 F 0.92840 1.05078 -0.1165 0% Void, No xenon Intermediate TModerator=2 0 0
° F TFueI=200° F 0.91531 1.04104 -0.1208 0% Void, No xenon 46 Hot Standby TModerator=5 ° F TFuel=546° F 0.86904 1.00975 -0.1394 0% Void, No xenon Hot OperatingNoxe TModerator=5 4 60 F TF,,eI= 9 8 9 ° F 0.86490 1.00503 -0.1394 0% Void, No xenon Hot Operating0 Taoderator=5 4 6 ° F TFueI=989° F 0.86495 1.00503 -0.1394 0% Void 46 Hot Operating 4 0 TModerator=5 ° F TFuet=989° F 0.83219 0.98706 -0.1569 40% Void 46 Hot Operating 8o TModerator=5 ° F TFuei=989° F 0.79080 0.96512 -0.1806 80% Void Table 2.113 Lattice [ ] Kinetics Parameters at BOL Kinetics Kinetics Parameter = kk aaee k*k kn (Ak/k)
Dplr= kHotOperatingNoXe - kHotStandby 1.00503 1.00975 -0.0047 Doppler
=kHotStandby Moeaovd= kHotOperating40 - k~otOperatingo 0.98706 1.00503 -0.0179 Modertorv~d =kHotOperating0 Mertreraue-kHotStandby - kCold 1.00975 1.05078 -0.0391 Modeatorempratue = kcold AREVA Inc.
Conro!edDocL en Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-111 Table 2.114BOL Lattice [ ] Control Blade Worths at for Control Blade Type GE OEM and D120 BaeWrh=kcontrotled - kuncontrolled kcontrolled kuncontroiied Blade kuncontrojied Worth
____ ____ ____(Ak/k)
Cold TModerator= 6 8 0 F TFueI=68 0 F 0.90635 1.05942 -0.1445 0% Void, No xenon Intermediate TModerator=2 0 0 0 F TFueI=200 0 F 0.89205 1 .05008 -0.1505 0% Void, No xenon 46 Hot Standby TModerator=5 ° F TFue1=546° F 0.84055 1.02089 -0.1767 0% Void, No xenon Hot Operatingaoxe TModerator=5 4 60 F TFueI=9 8 9 ° F 0.83678 1.01633 -0.1767 0% Void, No xenon 46 Hot Operating 0 TModerator=5 ° F TFUe!=989° F 0.83684 1.01633 -0.1766 0% Void 46 Hot Operating 40 mModerator=5 ° F TFuC!=989° F 0.79676 0.99848 -0.2020 40% Void 4 60 Hot Operating 50 TModerator=5 F TFueI=989 0 F 0.74354 0.97433 -0.2369 80% Void AREVA Inc.
Contro~ed Documeni Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-112 TableBOL2.115 for Lattice [ ] Control Blade Worths at Control Blade Type GE D160 and D190 Lower Blade BaeWrh=kcontrolled - kuncontrolied kcontroaled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator= 6 8 0 F TFuej=68° F 0.90466 1.05942 -0.1461 0% Void, No xenon Intermediate Taoderator=2 0 0 ° F TFueI=20 0 ° F 0.89044 1 .05008 -0.1520 0% Void, No xenon Hot Standby TModerator= 5 4 6 ° F TFueI=546° F 0.83885 1.02089 -0.1783 0% Void, No xenon 46 Hot Operatingaoxe TModerator=5 ° F TFueI=989° F 0.83509 1.01 633 -0.1783 0% Void, No xenon Hot Operating 0 TModerator=5 46
° F TFuei=9 8 9 ° F 0.83515 1.01 633 -0.1783 0% Void 46 Hot Operating 4 0 Taoderator=5 ° F TFUei=989° F 0.79444 0.99848 -0.2044 40% Void 4 6 Hot Operating 80 TModerator=5 ° F Tpuei=989° F 0.74028 0.97433 -0.2402 80% Void AREVA Inc.
C~ontrol~ed Docu2rl Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-113 Table 2.116 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D190 Blade Tip BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrolged Blade kuncontrolled Worth (Ak/k) 68 0 Cold TModerator= ° F m~ueI=68 F 0.90166 1.05942 -0.1489 0% Void, No xenon Intermediate TModerator=2 0 0 ° F TFueI=2 0 0 ° F 0.88725 1.05008 -0.1551 0% Void, NO xenon 46 Hot Standby TModerater=5 ° F TFuei=546° F 0.83410 1.02089 -0.1830 0% Void, NO xenon Hot OperatingNoxe mModerator= 5 4 6 ° F TFueI=9 89 ° F 0.83038 1.01633 -0.1830 0% Void, No xenon 46 Hot Operatingo TModerator=5 ° F TFueI=989 0 F 0.83038 1.01633 -0.1830 0% Void Hot Operating 4 0 TModerator=5 4 6
° F TFueg=989 0 F 0.78814 0.99848 -0.2 107 40% Void 4 60 Hot Operating 8o TModerator=5 F TFueI=989° F 0.73185 0.97433 -0.2489 80% Void AREVA Inc.
hiOUO! e@ DOur3lrrtt Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-114 Table 2.117 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D230 Lower Blade BaeWrh=kcontrolled - kuncontrolled kControlled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator=6 8 0 F mFueI=68 0 F 0.89450 1.05942 -0.1557 0% Void, No xenon Intermediate TModerator= 2 O 00 F TFueI=2000 F 0.87989 1.05008 -0.1621 0% Void, No xenon 46 Hot Standby TModerator=5 ° F TFueI=546° F 0.82541 1.02089 -0.1915 0% Void, No xenon 4 60 Hot Operatingaoxe TModerator=5 F TFueI=989 0 F 0.82173 1.01633 -0.1915 0% Void, No xenon 4
Hot Operating 0 TModerator=5 6° F TFueI=989° F 0.82178 1.01633 -0.1914 0% Void 46 Hot Operating 40 TModerator=5 ° F TFuel=989° F 0.77798 0.99848 -0.2208 40% Void 46 Hot Operating 80 TModerator=5 ° F TFueI=989 0 F 0.71955 0.97433 -0.2615 80% Void AREVA Inc.
Cont o!bd Docur ' ent Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-115 Table 2.118 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D230 Blade Tip laeW rh= kcontrolled " kuncontrolled kcontrolled kuncontrolled Blade kUncontrolied Worth (Ak/k)
Cold TModerator=6 8 ° F TFUeI=6 8 ° F 0.89791 1.05942 -0.1525 0% Void, No xenon Intermediate TModerator=2 0 0 0 F TFueI=200 0 F 0.88320 1.05008 -0.1589 0% Void, NO xenon 46 4 60 Hot Standby mModerator=5 ° F TFueI=5 F 0.82876 1.02089 -0.1882 0% Void, No xenon Hot Operatingaoxe TModerator=5 46
° F TFuei=989 0 F 0.82506 1.01633 -0.1882 0% Void, No xenon 4
Hot Operating 0 Taoderator=5 6° F TFueI=989° F 0.82506 1.01633 -0.1882 0% Void 46 Hot Operating 4 0 mModerator=5 ° F TFueI=989° F 0.78201 0.99848 -0.2168 40% Void 46 Hot Operating 80 T~oderator=5 ° F TFu 8 1=9 8 9° F 0.72482 0.97433 -0.2561 80% Void AREVA Inc.
OontroUed Document.
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-116 Table 2.119 Lattice [ ] Control BOL for Control Blade Type GE Marathon Blade Bottom Segment Blade Worths at BaeWrh=kcontrolled - kujncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator= 6 80 F TFuej=6 80 F 0.90752 1.05942 -0.1434 0% Void, No xenon Intermediate TModerator=2 0 0 ° F TFueI=2 0 0 ° F 0.89345 1.05008 -0.1492 0% Void, No xenon Hot Standby TModerator=5 4 60 F TFueI=5 4 6° F 0.84191 1.02089 -0.1753 0% Void, No xenon 46 Hot Operatingaoxe TModerator=5 ° F TFuei=989° F 0.83815 1.01633 -0.1753 0% Void, No xenon 46 Hot Operatingo T~oderator=5 ° F TFueI=989° F 0.83820 1.01633 -0.1753 0% Void 46 Hot Operating 40 TModerator=5 ° F TFue8=9890 F 0.79767 0.99848 -0.2011 40% Void 46 Hot Operating 80 Taoderator=5 ° F TFueI=9 8 9 ° F 0.74376 0.97433 -0.2366 80% Void AREVA Inc.
Contro~ec c.;urner~
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-117 Table 2.120 Lattice [
BOL for Control Blade Type GE Marathon Blade Main Segment
] Control Blade Worths at BaeWrh=kcontroIled - kuncontrolled kcontrolled kuncontroiiea Blade kuncontrolled Worth (Ak/k) 80 0 Cold TModerator=6 F TFueI=68 F 0.90108 1.05942 -0.1495 0% Void, No xenon Intermediate TModerator= 2 0 0 ° F TFueI=2 0 0 ° F 0.88681 1.05008 -0.1555 0% Void, No xenon Hot Standby TModerator= 5 4 6 0 F TFueI=5 4 60 F 0.83373 1.02089 -0.1833 0% Void, No xenon 46 Hot Operatingaoxe Taoderator=5 ° F TF,,e=989° F 0.83002 1.01 633 -0.1833 0% Void, NO xenon Hot Operating 0 mModerator= 5 4 6 0 F TFueI=989° F 0.83007 1.01633 -0.1833 0% Void Hot Operating 40 TModerator=5 46
° F TFueJ=9 8 9 ° F 0.78742 0.99848 -0.2114 40% Void 5 4 60 Hot Operating 8o TModerator= F TFueI=989° F 0.73057 0.97433 -0.2502 80% Void AREVA Inc.
~; ~Ld Do~u~net Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-118 Table 2.121 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Main BaeWrh-kControI~ed - kuncontrolled kcontrolled kunoontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator=6 8 ° F mFueI=68 0 F 0.90050 1.05942 -0.1500 0% Void, No xenon Intermediate TModerator= 2 0 0 ° F TFuei=2 0 0 ° F 0.88628 1.05008 -0.1560 0% Void, No xenon Hot Standby TModerator= 5 4 6 ° F TF,,eI=546° F 0.83364 1.02089 -0.1834 0% Void, No xenon 46 Hot OperatingNoxe TModerator=5 ° F TFueI=989° F 0.82992 1.01633 -0.1834 0% Void, No xenon 46 Hot Operating0 Taoderator=5 ° F TFuei=989 0 F 0.82999 1.01633 -0.1834 0% Void 46 Hot Operating 40 Taoderator=5 ° F TFueI=989° F 0.78818 0.99848 -0.2106 40% Void Hot Operating 80 TModerator=5 4 6
° F TFueI=9890 F 0.73228 0.97433 -0.2484 80% Void ARE VA Inc.
LJ~UIH~2HL Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-119 Table 2.122 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Tip BaeWrh-kcontrouled - kuncontrolled kcontrojjed kuncontrolled Blade kuncontrolled Worth (Ak/k) 6 80 Cold TModerator= F TFuei=68° F 0.92068 1.05942 -0.1310 0% Void, No xenon Intermediate mModerator=2 0 0 ° F TFuei=2 0 0 ° F 0.90721 1.05008 -0.1361 0% Void, No xenon Hot Standby TModerator=5 4 6 0 F TFueI=5 4 6 0 F 0.85970 1 .02089 -0.1579 0% Void, No xenon Hot OperatingNoxe TModerator=5 4 6 ° F TFueI=989° F 0.85583 1.01633 -0.1579 0% Void, No xenon Hot Operating0 mModerator=5 4 6° F T~uej=989° F 0.85583 1.01633 -0.1579 0% Void 460 Hot Operating 40 TModerator=5 F TFuel= 9 8 9 0 F 0.81954 0.99848 -0.1792 40% Void Hot Operating 80 TModerator=5 46
° F TFueI=989 0 F 0.77124 0.97433 -0.2084 80% Void AREVA Inc.
(1O onTutrou Doc .urrnenL Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-120 Table 2.123 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Tip BaeWrh kcontrol~ed " kuncontrolled kcontrolled kuncontrolled Blade
- kuncontrolled Worth
(,Ak/k) 680 Cold mModerator= F TFueI=68° F 0.90015 1.05942 -0.1503 0% Void, No xenon Intermediate TModerator=2 0 0 0 F TFueI=200° F 0.88578 1.05008 -0.1565 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFueI=546 0 F 0.83239 1.02089 -0.1846 0% Void, No xenon Hot OperatingNoxe TModerator= 54 6 ° F TFueI=9 8 9 ° F 0.82867 1.01633 -0.1846 0% Void, No xenon 4 60 Hot Operating 0 TModerator=5 F TFueI=989° F 0.82875 1.01633 -0.1846 0% Void 4 60 Hot Operating 4 o Tuoderator=5 F TFuel=989 0 F 0.78601 0.99848 -0.2128 40% Void 4 60 Hot Operating 8 0 TModerator=5 F TFueI=989° F 0.72857 0.97433 -0.2522 80% Void AREVA Inc.
conto Doecumnt Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-121 Table 2.124 BOL Lattice [ ] Control Blade Worths at for Control Blade Type CR99 Blade Main BaeW rh kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade
- kuncontrolled Worth
____ ____ ____(Akdk) 68 Cold TModerator= ° F TFueI=68° F 0.89869 1.05942 -0.1517 0% Void, No xenon Intermediate TModerator=2 0 0 ° F TFueI=200° F 0.88429 1.05008 -0.1579 0% Void, No xenon Hot Standby mModerator=5 4 60 F TF,,ei546° F 0.83052 1.02089 -0.1865 0% Void, No xenon Hot OperatingNoxe TModerator=5 46
° F TFueI= 9 8 9 ° F 0.82682 1.01 633 -0.1865 0% Void, No xenon Hot Operating 0 TModerator=5 4 6 0 F TFueI=989° F 0.82689 1.01633 -0.1864 0% Void 4 60 Hot Operating 4 0 TModerator=5 F T~ueC=989° F 0.78367 0.99848 -0.2151 40% Void Hot Operating 80 TModerator=5 4 6 ° F TFuej=989 0 F 0.72553 0.97433 -0.2554 80% Void AREVA Inc.
Controi ed Dccu.mn- t Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM I0XM Fuel Page 2-122 Table 2.125 Lattice [ ] Control Blade BOL for Control Blade Type GE Marathon Ultra HD2 Worths at BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrolied Blade kuncontrolled Worth (Ak/k)
Cold TModerator= 6 8 ° F TFueI=68 0 F 0.92089 1.05942 -0.1308 0% Void, No xenon Intermediate TModerator=2 0 00 F TFuei=2 0 0 ° F 0.90727 1.05008 -0.1360 0% Void, No xenon 46 46 Hot Standby TModerator=5 ° F TFueI=5 ° F 0.85820 1.02089 -0.1594 0% Void, No xenon 46 Hot OperatingNoxe mModerator=5 ° F TFue1=989° F 0.85434 1.01633 -0.1594 0% Void, NO xenon 4 60 Hot Operating 0 TModerator=5 F TFueI=989° F 0.85439 1 .01633 -0.1593 0% Void 46 Hot Operating 4 o TModerator=5 ° F TFuel=989° F 0.81630 0.99848 -0.1825 40% Void Hot Operating 80 TModerwtor=5 46° F TFue1=989° F 0.76502 0.97433 -0.2148 80% Void AREVA Inc.
Corftro~~d Focurrent Nuclear Fuel D~esign Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-123 Table 2.126 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD3 gdeWrh=kcontroIled "kuncontroiled kcontrorled kunoontrolled Blade kuncontrolled Worth
_______________________(Ak/k)
Cold TModerator= 6 8 ° F TFueI=68° F 0.94244 1.05942 -0.1104 0% Void, No xenon Intermediate TModerator=2 0 00 F TFueI=200° F 0.92955 1.05008 -0.1148 0% Void, NO xenon 46 Hot Standby TModerator=5 ° F TFuel=546° F 0.88466 1.02089 -0.1334 0% Void, No xenon Hot OperatingNoxe TMederator= 5 4 60 F TFuej=9890 F 0.88064 1.01633 -0.1335 0% Void, No xenon 46 Hot Operatingo Taoderator=5 ° F TFueI=989° F 0.88068 1.01 633 -0.1335 0% Void 46 Hot Operating 4 0 TModerator=5 ° F TFueI=989° F 0.84698 0.99848 -0.1517 40% Void 460 Hot Operating 80 Tuoderator=5 F TFueI=989° F 0.80105 0.97433 -0.1779 80% Void AREVA Inc.
Cothrro~Led Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-124 Table 2.127 Lattice [ ] Kinetics Parameters at BOL Kinetics Kinetics Parameter ka- k aaee kKt% k* (Ak/k)
Dper kHotOperatingNoXe - kHotStandby 1.01633 1.02089 -0.0045 Dopper
=kHotStanldby Mertrld= kHotOperating4o - kHotOperatingo 0.99848 1.01633 -0.0176 Modertorvid =kHotOperatingo ModeratorTemperature -
kHotStandby " kCold kcojd 1.02089 1.05942 -0.0364 AREVA Inc.
(3ontrc4k3d iDocument Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-125 Table 2.128 Lattice [
BOL for Control Blade Type GE OEM and D120
] Control Blade Worths at BaeWrh=kcontroiled - kuncontrolled k~cntrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator=6 8° F TFueI=68 0 F 0.91544 1.06926 -0.1439 0% Void, No xenon Intermediate Taoderator=2 0 0 ° F TFuei= 2 0 00 F 0.90164 1.06059 -0.1499 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFuej=546 0 F 0.85280 1.03526 -0.1762 0% Void, No xenon 89 Hot OperatingNoxe TModerator= 5 4 6 ° F TFueI=9 °F 0.84903 1.03070 -0.1763 0% Void, No xenon Hot Operating0 TModerator=5 4 6
° F TFueC=989 0 F 0.84910 1.03070 -0.1762 0% Void 46 Hot Operating 4 o TModerator=5 ° F TFueI=98 90 F 0.81 022 1.01 507 -0.2018
=40% Void Hot Operating 80 TModerator=5 46
° F TFueI=989 0 F 0.75790 0.99362 -0.2372 80% Void AREVA Inc.
Contro~ed Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-126 Table 2.129 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D160 and D190 Lower Blade BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator= 6 8 ° F TFuei=68 0 F 0.91374 1.06926 -0.1454 0% Void, NO xenon Intermediate TModerator= 2 0 0 ° F TFuei=2 0 00 F 0.90000 1.06059 -0.1514 0% Void, No xenon 46 Hot Standby TModerator=5 ° F TF,,eI=54 6 ° F 0.85107 1.03526 -0.1779 0% Void, No xenon Hot OperatingNoxe TModerator=5 4 6 ° F TFuCI=989° F 0.84732 1.03070 -0.1779 0% Void, No xenon 4 60 Hot Operating 0 TModerator=5 F TFueI=989 0 F 0.84737 1.03070 -0.1779 0% Void 46 Hot Operating 4 o TModerator=5 ° F TFueI=989° F 0.80786 1.01 507 -0.2041 40% Void 4 60 Hot Operating 80 mModerator=5 F TFueI=989° F 0.75455 0.99362 -0.2406 80% Void AREVA Inc.
?_on tro ed Dcmn Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 10XM Fuel Page 2-127 Table 2.130 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D190 Blade Tip BaeWrh=kcontroljed "kuncontrolled kcontronled kuncontroi led Blade kuncontrolled Worth (Ak/k)
Cold TModerator=6 8° F Tpuei=68 0 F 0.91071 1.06926 -0.1483 0% Void, No xenon Intermediate TModerator=2 0 0 ° F TFUCI=2 0 0 0 F 0.89678 1.06059 -0.1545 0% Void, No xenon Hot Standby TModerator=5 4 6° F TFueI=5 4 6 ° F 0.84625 1.03526 -0.1826 0% Void, NO xenon 46 89 Hot OperatingNoxe TModerator=5 ° F TFueI=9 ° F 0.84254 1.03070 -0.1826 0% Void, No xenon 46 Hot Operating 0 TModerator=5 ° F TF,,e=989° F 0.84254 1.03070 -0.1826 0% Void 89 Hot Operating 4 0 TModerator=5 46
° F TFuel=9 ° F 0.80143 1.01 507 -0.2105 40% Void 46 9 8 90 Hot Operating 80o TModerator=5 ° F TFueI= F 0.74588 0.99362 -0.2493 80% Void AREVA Inc.
ConJtrt .... Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-128 Table 2.131 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0230 Lower Blade BaeWrh-kcontrolued " kuncontrolled kcontrotled kuncontrolled Blade kuncontrolledWot (Ak/k)
Cold TModerator= 6 8 0 F TFueI=68° F 0.90349 1.06926 -0.1550 0% Void, No xenon Intermediate TModerator=2 0 0 ° F TFueI= 2 000 F 0.88933 1.06059 -0.1615 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFue!546° F 0.83742 1.03526 -0.1911 0% Void, No xenon 4 60 Hot OperatingNoxe TModerator=5 F T~uej=989° F 0.83375 1.03070 -0.1911 0% Void, NO xenon 46 Hot Operating 0 TModerator=5 ° F TFuel=989° F 0.83380 1.03070 -0.1910 0% Void 4 60 Hot Operating 4 0 mModerator=5 F TFueI=989° F 0.79106 1.01507 -0.2207 40% Void Hot Operating 8 0 TModerator=5 46
° F TFueI=9890 F 0.73328 0.99362 -0.2620 80% Void AREVA Inc.
Crru'oIedDo oumnern Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 10XM Fuel Page 2-129 Table 2.132 Lattice [ ] Control Blade BOL for Control Blade Type GE D230 Blade Tip Worths at BaeWrh=kcontrol~ed - kuncontrolled koontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator= 6 80 F TFueI=6 8 ° F 0.90694 1.06926 -0.1518 0% Void) No xenon Intermediate Taoderator=2 0 00 F TFueI=20 00 F 0.89270 1.06059 -0.1583 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFueI=546° F 0.84083 1.03526 -0.1878 0% Void, No xenon 46 Hot OperatingNoxe TModerator=5 ° F TFue6 =989° F 0.83714 1.03070 -0.1878 0% Void, NO xenon 46 Hot Operatingo TModerator=5 ° F TFuez=989° F 0.83714 1.03070 -0.1878 0% Void Hot Operating 4 o TModerator=5 46
° F TFueI=9 89° F 0.79518 1.01 507 -0.2166 40% Void Hot Operating 80 46 89 TModerator=5 ° F TFueI=9 °F 0.73867 0.99362 -0.2566 80% Void AREVA Inc.
"*"'q*"CDLocumlen~t.
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-130 Table 2.133 Lattice [ ] Control Blade BOL for Control Blade Type GE Marathon Blade Bottom Segment Worths at BaeWrh=kcontrolled - kuncontrolled kcontroljed kuncontrolled Blade kuncontrolled Worth
________________(Ak/k)
Cold TModerator=6 8 ° F TFueI=6 80 F 0.91660 1.06926 -0.1428 0% Void, NO xenon Intermediate TModerator= 2 0 0 0 F TF,,OI=2 0 0 ° F 0.90303 1.06059 -0.1486 0% Void, No xenon Hot Standby TModerator= 5 4 6 0 F TFueI=546° F 0.85415 1.03526 -0.1749 0% Void, No xenon 4 60 Hot OperatingaoxC Taoderator=5 F TFueI=989° F 0.85039 1.03070 -0.1749 0% Void, NO xenon Hot Operating 0 Taoderator= 5 4 6 0 F TFuei=989° F 0.85045 1.03070 -0.1749 0% Void 4 60 Hot Operating 40 TaoderatOr=5 F TFueI=989 0 F 0.81111 1 .01507 -0.2009 40% Void 4 60 Hot Operating 80 TModerator=5 F TFueI=989° F 0.75806 0.99362 -0.2371 80% Void AREVA Inc.
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page 2-131 Table 2.134 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Main Segment BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade BaeWrh= kuncontrolled Worth (Ak/k)
Cold mModerator= 6 8 ° F mFueI=68 0 F 0.91011 1.06926 -0.1488 0% Void, No xenon Intermediate TModerator=2 0 00 F TFuel= 2O 00 F 0.89632 1.06059 -0.1549 0% Void, No xenon 46 4 60 Hot Standby TModerator=5 ° F TFueI=5 F 0.84585 1.03526 -0.1830 0% Void, No xenon Hot OperatingNoxe TModerator=5 46
° F TFueI=989 0 F 0.84215 1.03070 -0.1829 0% Void, No xenon 46 Hot Operating 0 TModerator=5 ° F TFue1=989 0 F 0.84220 1.03070 -0.1829 0% Void 46 Hot Operating 40 TModerator=5 ° F TFueI=989° F 0.80066 1.01507 -0.2112 40% Void 46 Hot Operating 50 TModerator=5 ° F T~uei=989° F 0.74455 0.99362 -0.2507 80% Void AREVA Inc.
Jontro r r rn JO1 -
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 10XM Fuel Page 2-132 Table 2.135 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Main BaeWrh=kcontrolled " kUncontrolled kcontrolled kuncontroiied Blade kuncontrolled Worth (Ak/k) 68 Cold TModerator= ° F TFueI=68° F 0.90951 1.06926 -0.1494 0% Void, No xenon TModerator=2 0 0 Intermediate ° F T~uei=200° F 0.89578 1.06059 -0.1554 0% Void, No xenon 4 60 Hot Standby Tuoderator=5 F TFueI=546° F 0.84574 1.03526 -0.1831 0% Void, No xenon Hot Operatingaoxe TModierator=54 6 ° F TFueI=989 0 F 0.84204 1.03070 -0.1830 0% Void, No xenon 46 Hot Operatingo0 Taoderator=5 ° F TFe1=989° F 0.84211 1.03070 -0.1830 0% Void 4 6 Hot Operating 40 TModerator=5 ° F TFueI=989° F 0.80143 1.01507 -0.2105 40% Void 4 60 Hot Operating 80 TModerator=5 F TFueI=989° F 0.74631 0.99362 -0.2489 80% Void AREVA Inc.
Contro~Ied Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 10XM Fuel Page 2-133 Table 2.136 Lattice [ ] Control BOL for Control Blade Type CR82M1 and CR82B Blade Tip Blade Worths at BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator=6 8° F TFueI=68 0 F 0.92991 1.06926 -0.1303 0% Void, No xenon Intermediate TModerator=2 0 0 0 F TFueI=200° F 0.91695 1.06059 -0.1354 0% Void, No xenon 4 60 Hot Standby 'TModerator=5 F TFueI=546° F 0.87225 1.03526 -0.1575 0% Void, NO xenon Hot OperatingNoxC mMederator=5 4 60 F TFueI=9 890 F 0.86837 1.03070 -0.1575 0% Void, No xenon 4 60 Hot Operatingo mModerator=5 F TFuei=989° F 0.86837 1 .03070 -0.1575 0% Void 460 Hot Operating 4 0 mModerator=5 F TFueI=989° F 0.83345 1.01507 -0.1789 40% Void 46 Hot Operating 80 mModerator=5 ° F TFueC=989° F 0.78630 0.99362 -0.2087 80% Void AREVA Inc.
o~e
.... Dc. u.I en*'
Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page 2-134 Table 2.137 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Tip Bae- kcontrolled " kuncontrolled kcontrolled kuncontrolied Blade BaeWorth = kuncontrolled Worth (Ak/k) 68 68 Cold TModerator= ° F TFuei= ° F 0.90918 1.06926 -0.1497 0% Void, No xenon Intermediate TModerator=2 0 0 0 F TF eI=200° F 0.89529 1.06059 -0.1559 0% Void, No xenon Hot Standby TModerator=5 46
° F TFUeI=5 4 6° F 0.84450 1.03526 -0.1843 0% Void, No xenon 54 6 Hot OperatingNoxe TModerator= ° F mFueI=989 0 F 0.84079 1.03070 -0.1842 0% Void, No xenon 46 Hot Operatingo TModerator=5 ° F TFueI=989 0 F 0.84087 1.03070 -0.1842 0% Void 46 Hot Operating 40 TModerator=5 ° F TF,,e=989° F 0.79925 1.01 507 -0.2126 40% Void Hot Operating 80 TModerator=5 46
° F TFu 6 1=9 8 9 ° F 0.74256 0.99362 -0.2527 80% Void AREVA Inc.
Cc.intro~ed Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-135 Table 2.138 Lattice [ ] Control BOL for Control Blade Type CR99 Blade Main Blade Worths at BaeWrh=kcontrolled " kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator=6 8° F TFuei=68° F 0.90770 1.06926 -0.1511 0% Void, No xenon Intermediate TModerator= 2 0 0 ° F Tpuei=200 0 F 0.89377 1.06059 -0.1573 0% Void, NO xenon Hot Standby mModeirator=5 46
° F TFueI=546 0 F 0.84260 1.03526 -0.1861 0% Void, No xenon_____
46 Hot OperatingNoxe T~oderator=5 ° F TFueI=989° F 0.83890 1.03070 -0.1861 0% Void, No xenon 4 60 Hot Operating 0 TModertor=5 F TFueI=989° F 0.83898 1.03070 -0.1860 0% Void 46 Hot Operating 40 TModerator=5 ° F TFueI=989 0 F 0.79686 1.01507 -0.2150 40% Void Hot Operating 80 mModerator=5 4 60 F TFueI=9890 F 0.73945 0.99362 -0.2558 80% Void AREVA Inc.
C"ontro * - ed o; Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-136 Table 2.139 Lattice [
BOL for Control Blade Type GE Marathon Ultra HD2
] Control Blade Worths at BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k) 68 Cold mModerator= ° F TFueI=68° F 0.93013 1.06926 -0.1301 0% Void, No xenon Intermediate TModerator=2 0 00 F TFueI=200 0 F 0.91701 1.06059 -0.1354 0% Void, No xenon Hot Standby TModerator= 5 4 6 ° F T~ueI=546 0 F 0.87074 1.03526 -0.1589 0% Void, No xenon 46 Hot OperatingNoxe TModerator=5 ° F TFueI=9 8 9 ° F 0.86688 1.03070 -0.1589 0% Void, No xenon Hot Operating 0 TModerator=5 4 6 0 F TFuei=989° F 0.86693 1 .03070 -0.1589 0% Void 46 Hot Operating 4 o TModerator=5 ° F TFueI=989° F 0.83018 1.01507 -0.1822 40% Void Hot Operating 8 0 TModerator=5 4 60 F TFueI=989 0 F 0.77998 0.99362 -0.2150 80% Void AREVA Inc.
COntr u! ed Doc&umqient*
Nuciear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-137 Table 2.140 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD3 BaeWrh=kcontrolled " kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator=6 8 0 F TFuej=68° F 0.951 89 1.06926 -0.1098 0% Void, No xenon Intermediate TModerator= 2 O 00 F TFuer=2 0 0° F 0.93955 1.06059 -0.1141 0% Void, No xenon 46 Hot Standby Tuoderator=5 ° F T~ue=546° F 0.89764 1.03526 -0.1329 0% Void, No xenon Hot Operatingaoxe TModerator=5 4 6 ° F TFueI=9 8 9 ° F 0.89363 1 .03070 -0.1330 0% Void, No xenon Hot Operatingo TModerator= 5 4 6 ° F TFUeI=989° F 0.89367 1.03070 -0.1330 0% Void 4 6 Hot Operating 40 Tuoderator=5 ° F TFu 0 I=989° F 0.86151 1.01507 -0.1513 40% Void 4 60 Hot Operating 80 Tuoderator=5 F TFueI=989° F 0.81705 0.99362 -0.1777 80% Void Table 2.141 Lattice [ ] Kinetics Parameters at BOL Kinetics Kinetics Parameter=ka-Pamer k*k k (Ak/k)
Dplr= kHaotperatingNoXe - kHotStarndby 1.03070 1.03526 -0.0044 Dopper
=kHotStandby MdrtrCd= kHotaperating4o - ki-otOperatingo 1,.01507 1,.03070 -0.0152 Modertorvid =kHotOperatingo
_ kHotStandby - kCold 1.03526 1.06926 -0.0318 ModeratorTemperature - kCold AREVA Inc.
CnrhADocu ment Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-138 Table 2.142 Lattice [ XMLCB-4523L-12G80 ] Control Blade Worths at BOL for Control Blade Type GE OEM and D120 BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontro, led Blade BaeWrh= kuncontrolied Worth (Ak/k)
Cold TModerator=6 8 0 F TFue1=68° F 0.99162 1.14917 -0.1371 0% Void, No xenon Intermediate Taoderator=2 0 0
° F TFueI= 2 0 00 F 0.97775 1.14039 -0.1426 0% Void, No xenon Hot Standby 4 6 46 TModeretor=5 ° F TFueI=5 °F 0.91 925 1.10578 -0.1687 0% Void, No xenon 4 60 Hot OperatingNoxe TModerator=5 F TFueI=930° F 0.91518 1.10092 -0.1687 0% Void, No xenon Hot Operating 0 TModeretor=5 4 6 0 F TFuel=930° F 0.91 525 1.10092 -0.1686 0% Void 46 Hot Operating 4 0 TModerator=5 ° F TFueI=930° F 0.87072 1 .07923 -0.1932 40% Void Hot Operating 80 TModerator=5 46
° F TFue1=930 0 F 0.81619 1.05218 -0.2243 80% Void AREVA Inc.
O~i,.,e uot rl ~
Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-139 Control[ Blade Type GE D160 and TableBOL2.143 for Lattice ] Control D190 Lower Blade Blade Worths at BaeWrh=kcontrolled -kuncontrolIed kcontroiieei kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator= 6 8 ° F TFuei=68° F 0.98976 1.14917 -0.1387 0% Void, NO xenon Intermediate TModerator=2 0 00 F TFuel= 2O 00 F 0.97589 1.14039 -0.1442 0% Void, No xenon 46 Hot Standby TModerator=5 ° F T~uel=546° F 0.91728 1.10578 -0.1705 0% Void, No xenon Hot Operatingaoxe :TModerator=5 46
° F TFueJ=9 3 0° F 0.91323 1.10092 -0.1705 0% Void, NO xenon 4 6 Hot Operating 0 Taoderator=5 ° F TFueI=930° F 0.91 329 1.10092 -0.1704 0% Void 4 60 Hot Operating 4 o TModerator=5 F TFueI=930° F 0.86811 1.07923 -0.1956 40% Void Hot Operating 80 T~oderator=5 46
° F TFuei=93 0 ° F 0.81259 1.05218 -0.2277 80% Void AREVA Inc.
~ on~ u~d Document
~A Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-140 Table 2.144 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D190 Blade Tip BaeWrh=kcontrolled - kuncontrolied kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold mModerator=6 8 ° F TFuej=68 0 F 0.98669 1.14917 -0.1414 0% Void, No xenon Intermediate mModerator=2 0 0 0 F TFueI=2 0 0 ° F 0.97257 1.14039 -0.1472 0% Void, No xenon Hot Standby TModerator=5 4 6
° F TFueI=546 0 F 0.91214 1.10578 -0.1751 0% Void, No xenon Hot OperatingNoxe TModerator= 54 6 ° F TFueI=930° F 0.90813 1.10092 -0.1751 0% Void, No xenon 46 Hot Operating 0 TModerator=5 ° F TFueI=930° F 0.90813 1.10092 -0.1751 0% Void 46 Hot Operating 40 TModerator=5 ° F TFueI=930° F 0.86136 1.07923 -0.2019 40% Void 60 Hot Operating 8 0 TModerator=54 F TF,,eI930° F 0.80375 1.05218 -0.2361 80% Void AREVA Inc.
ti d Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-141 Table 2.145 Lattice [ ] Control BOL for Control Blade Type GE D230 Lower Blade Blade Worths at BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k) 80 Cold TModerator=6 F TFueI=68° F 0.97914 1.14917 -0.1480 0% Void, No xenon Intermediate TModerator= 2 0 0
° F TFueI=200° F 0.96486 1.14039 -0.1539 0% Void, No xenon 46 Hot Standby TModerator=5 ° F TFueI=546° F 0.90312 1.10578 -0.1833 0% Void, No xenon 46 Hot OperatingNoxe TModerator=5 ° F TFue;=930° F 0.89915 1.10092 -0.1833 0% Void, No xenon Hot Operating 0 TMederator=5 4 60 F TFuei=93O0 F 0.89921 1.10092 -0.1832 0% Void 46 Hot Operating 40 T~oderator=5 ° F TFueI=93 0 ° F 0.85085 1.07923 -0.2116 40% Void 46 9 Hot Operating 80 TModerator=5 ° F TFueI= 300 F 0.79122 1.05218 -0.2480 80% Void AREVA Inc.
C~ontr3~ed Eiocumen~
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page 2-142 Table 2.146 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0230 Blade Tip BaeWrh kcontrolled - kuncontrolled kcontroljed kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator=6 8 ° F TFueI=68° F 0.98283 1.14917 -0.1447 0% Void, No xenon Intermediate TModerator=2 0 0 0 F TFueI=200° F 0.96845 1.14039 -0.1508 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFueI=546° F 0.90672 1.10578 -0.1800 0% Void, No xenon Hot OperatingNoxe TModerator= 5 4 6 ° F TFueI=930° F 0.90273 1.10092 -0.1800 0% Void, No xenon 46 Hot Operatingo mModerator=5 ° F TFueI=930° F 0.90273 1.10092 -0.1800 0% Void Hot Operating 4 0 TModerator=5 46
° F TFueI=930 0 F 0.85519 1.07923 -0.2076 40% Void 4 60 Hot Operating 80 TModerator=5 F TFueI=930° F 0.79680 1 .05218 -0.2427 80% Void AREVA Inc.
Cortoted Documn Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-143 Table 2.147 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Bottom Segment BaeWrh=kcontrolled " kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth
____ ____ ___ ___ ___(Ak/k)
Cold mModerator=6 8 0 F TFuej=68° F 0.99372 1.14917 -0.1353 0% Void, No xenon Intermediate mModerator=2 0 0 ° F TFueI=200° F 0.98000 1.14039 -0.1406 0% Void, No xenon 46 Hot Standby TModerator=5 ° F TFueC=546° F 0.92125 1.10578 -0.1669 0% Void, No xenon Hot OperatingNoxe TModerator= 5 4 6 0 F T~uei=930° F 0.91719 1.10092 -0.1669 0% Void, No xenon 46 Hot Operating 0 TModerator=5 ° F TFue==930° F 0.91724 1.10092 -0.1668 0% Void 460 Hot Operating 4 0 TModerator=5 F TFueI=930 0 F 0.87231 1.07923 -0.1917 40% Void 46 Hot Operating 80 TModerator=5 ° FTmFueI=930° F 0.81717 1.05218 -0.2234 80% Void AREVA Inc.
OontroUe'i Doe ~~enL Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-144 Table 2.148 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Main Segment laeWth=kcontroiled - kuncontroIled koontrolied kuncontroaiedi Blade kuncontrolled Worth (Ak/k) 6 80 Cold TModerator= F TFueI=68 0 F 0.98638 1.14917 -0.1417 0% Void, No xenon 0 00 Intermediate mModerator=2 F mFueI=200 0 F 0.97243 1.14039 -0.1473 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFueI=546 0 F 0.91195 1.10578 -0.1753 0% Void, No xenon Hot OperatingNoxe TModerator=5 46
° F TFuel= 9 3 O0 F 0.90794 1.10092 -0.1753 0% Void, No xenon 46 Hot Operating 0 TModerator=5 ° F TFueI=9 3 0 ° F 0.90800 1.10092 -0.1752 0% Void 46 Hot Operating 4 0 TModerator=5 ° F TFueI=930° F 0.86086 1.07923 -0.2023 40% Void 46 Hot Operating8B0 TModerator=5 ° F TFueI=93O0 F 0.80281 1.05218 -0.2370 80% Void AREVA Inc.
Cantro~L~d Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-145 Table 2.149 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Main kcontrolled - kuncontrolIed Blade Worth = kncnrle Cold TModerator= 6 8 0 F TFuej=6 8 ° F 0% Void, NO xenon Intermediate TModerator=2 00
° F TFueI=2 0 0 0 F 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFueC=546° F 0% Void, No xenon Hot Operatingaoxe TModerator=5 4 6 ° F TFuet= 9 3 0° F 0% Void, No xenon Hot Operating 0 TModerator=5 4 60 F TF~eI=9 3 00 F 0% Void Hot Operating 40 mModerator=5 4 6 ° F TFueI=9 3O0 F 40% Void Hot Operating 80 TModerator=5 4 6 ° F TFu 8 1=9 3 0° F 80% Void AREVA Inc.
(Controiled Docwmn Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-146 Table 2.150 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82MI and CR82B Blade Tip BaeWrh=kcontrolled - kUncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth
____ ____ ____(Ak/k) 6 80 Cold TModerator= F TFueI=68° F 1.00837 1.14917 -0.1225 0% Void, No xenon Intermediate TModerator= 2 O 00 F TFueI=2 0 0° F 0.99534 1.14039 -0.1272 0% Void, No xenon Hot Standby Taoderator=5 4 6° F TFueI=5 4 60 F 0.94110 1.10578 -0.1489 0% Void, No xenon 46 Hot Operatingaoxe TModerator=5 ° F TFueI=930° F 0.93691 1.10092 -0.1490 0% Void, No xenon Hot Operating 0 TModer~ator= 5 4 6 0 F T~uei=930° F 0.93691 1.10092 -0.1490 0% Void 4
Hot Operating 40 Taoderator=5 6° F TFueI=930° F 0.89646 1.07923 -0.1694 40% Void Hot Operating 80 T~oderator=5 4 60 F TFueI=930 0 F 0.84672 1.05218 -0.1953 80% Void AREVA Inc.
oiled Doodment Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 10XM Fuel Page 2-147 Table 2.151 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Tip BaeWrh=kcontrolled " kuncontrolled koontrolled kuncontrolled Blade kUncontrolied Worth (Ak/k)
Cold TModerator=6 8 0 F TFuel=68 0 F 0.98536 1.14917 -0.1426 0% Void, No xenon Intermediate TModerator=2 00
° F TFueI=200° F 0.97138 1.14039 -0.1482 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFueI=546° F 0.91076 1.10578 -0.1764 0% Void, No xenon Hot Operatingaoxe T~ederator=5 4 6
° F TFueI=93 0 ° F 0.90675 1.10092 -0.1764 0% Void, No xenon 4 60 Hot Operating 0 TModerator=5 F TFueI=930° F 0.90683 1.10092 -0.1763 0% Void 46 Hot Operating 40 TModerator=5 ° F TFueI=930° F 0.85958 1.07923 -0.2035 40% Void 4 6 Hot Operating 80 TModerator=5 ° F TFueI=930° F 0.80083 1 .05218 -0.2389 80% Void AREVA Inc.
Con ...... DoeUL CUme,., n, Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-148 Table 2.152 Lattice [
BOL for Control Blade Type CR99 Blade Main
] Control Blade Worths at BaeWrh=kcontrolled " kuncontrolled koontrolled kUncontroiled Blade kuncontrolled Worth
____ ____ ___(Ak/k)
Cold TModerator= 6 8
° F TFuei=68° F 0.98379 1.14917 -0.1439 0% Void, No xenon Intermediate TModerator= 2 0 0 ° F TFueI=200 0 F 0.96976 1.14039 -0.1496 0% Void, No xenon Hot Stand by TModerator= 5 4 6 ° F TFueI=546° F 0.90872 1.10578 -0.1782 0% Void, NO xenon Hot OperatingNoxe TModerator= 5 4 6 ° F TFueI=9 3 0° F 0.90473 1.10092 -0.1782 0% Void, NO xenon 46 Hot Operating 0 TModerator=5 ° F TFuel=930° F 0.90481 1.10092 -0.1781 0% Void 46 Hot Operating 40 TModerator=5 ° F TFueI=930 0 F 0.85704 1 .07923 -0.2059 40% Void Hot Operating 80 TModerator=5 4 60 F TFueI=9 3 0° F 0.79760 1.05218 -0.2419 80% Void AREVA Inc,
Ccnto'Ld Docurnc~nt Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-149 Table 2.153 Lattice [ ] Control BOL for Control Blade Type GE Marathon Ultra HD2 Blade Worths at BaeWrh=kcontrolled - kuncontrolled koontrolled kuncontrolled Blade kuncontrolted Worth (Ak/k)
Cold TModerator= 6 8 ° F mFueI=68 0 F 1.00696 1.14917 -0.1237 0% Void, No xenon Intermediate TModerator= 2 0 0 ° F TFUeI=200° F 0.99369 1.14039 -0.1286 0% Void, No xenon 4 60 Hot Standby mModerator=5 F TFueI=546° F 0.93742 1.10578 -0.1522 0% Void, No xenon 46 Hot OperatingNoxe TModerator=5 ° F TFueI=930° F 0.93326 1.10092 -0.1523 0% Void, No xenon 46 Hot Operating 0 TModerator=5 ° F TFueI=93O0 F 0.93331 1.10092 -0.1522 0% Void 460 Hot Operating 4 0 mModerator=5 F TFuel=930° F 0.89069 1.07923 -0.1747 40% Void 46 Hot Operating 8 0 TModerator=5 ° F TFueI=930° F 0.83791 1.05218 -0.2036 80% Void AREVA Inc.
UOCU~T~flI Nuclear Fuel Design Report AN P-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-150 Table 2.154 Lattice [
BOL for Control Blade Type GE Marathon Ultra HD3
] Control Blade Worths at gdeWrh=kcantrolled " kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator=6 8 ° F TFueI=68° F 1.02933 1.14917 -0.1043 0% Void, No xenon Intermediate TModerator= 2 0 0 0 F TFueI=200° F 1.01676 1.14039 -0.1084 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFueI546° F 0.96493 1.10578 -0.1274 0% Void, No xenon Hot Operatingaoxe T~ocierator= 5 4 6 0 F TFuej=930° F 0.96060 1.10092 -0.1275 0% Void, No xenon Hot Operating 0 TModerator= 5 4 6 ° F TFueI=930° F 0.96065 1.10092 -0.1274 0% Void Hot Operating 40 T~oderator=5 4 6
° F TFuel=930 0 F 0.92240 1.07923 -0.1453 40% Void 46 Hot Operating 8 o TModerator=5 ° F TFueI=930° F 0.87465 1.05218 -0.1687 80% Void Table 2.155 Lattice [ ] Kinetics Parameters at BOL Kinetics Kinetics Parameter =K-k*k k aaee (Ak/k)
Dplr= kHotaperatingNoXe - kHotStandby 1 .10092 1 .10578 -0.0044 Dopper
=kHotStandby Mdrtrld= kHotOperating40 - kHotOperating0 1 .07923 1 .10092 -0.0197 Modertorvid =kHotOperating0 kHotStandby " koald 1.10578 1.149 17 -0.0378 ModeratorTemperature - kcold AREVA Inc.
Control!ed Dock, m=,r Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-151 Table 2.156 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE OEM and 0120 BaeWrh=kcontrolled " kuncontrofled kControfled kuncontrofled Blade kunlcontrolled Worth (Aklk)
Cold TModerator= 6 8 ° F TFueI=6 8 ° F 0.92547 1.08498 -0.1470 0% Void, No xenon Intermediate TModerator=2 0 0 0 F TFu 8 1=200° F 0.91218 1.07695 -0.1530 0% Void, NO xenon 460 Hot Standby TModerator=5 F TFueI=546° F 0.85911 1.04807 -0.1803 0% Void, NO xenon Hot OperatingNoxe TModerator=5 4 6° F TFueI=98 9 ° F 0.85509 1.04319 -0.1803 0% Void, NO xenon Hot Operating0 TModerator=5 46
° F TFueI=9 8 9 ° F 0.85516 1.04319 -0.1802 0% Void 46 Hot Operating 4 o TModerator=5 ° F TFueI=98 9 ° F 0.81437 1.02535 -0.2058 40% Void Hot Operating 80 mModerator=5 460 F TFueI=98 9 ° F 0.76290 1.00194 -0.2386 80% Void AREVA Inc.
UGont roJt!ed .... n" Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-152 Table 2.157 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D160 and D190 Lower Blade BaeWrh=kcontralled - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator=6 8
° F TFueI=6 8 ° F 0.92373 1.08498 -0.1486 0% Void, No xenon Intermediate TModerator=2 0 0 ° F TFueI200° F 0.91050 1.07695 -0.1546 0% Void, No xenon Hot Standby TModerator=5 4 6° F TFueI=546 0 F 0.85731 1.04807 -0.1820 0% Void, No xenon Hot OperatingNoxe TModerator=5 4 6
° F TFuei=989 0 F 0.85332 1.04319 -0.1820 0% Void, No xenon 4
Hot Operating 0 TModerator=5 6° F TFueI=989 0 F 0.85337 1.04319 -0.1820 0% Void Hot Operating 4 0 mModerator=5 46
° F TFueI=98 9 ° F 0.81194 1.02535 -0.2081 40% Void 46 Hot Operating 80 TModerator=5 ° F TFueI=989 0 F 0.75950 1.00194 -0.2420 80% Void AREVA Inc.
Contro~led DocL: 'ment Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-153 Table 2.158 Lattice [
at BOL for Control Blade Type GE D190 Blade Tip
] Control Blade Worths BaeWrh=kcontrc!:ed " kuncontrolled kcontrol led kuncontrorled Blade kuncontrolled Worth (Aklk)
Cold TModerator=6 8° F TFuei=68° F 0.92066 1.08498 -0.1515 0% Void, No xenon Intermediate TModerator=2 0 0 0 F Tpuei=200° F 0.90721 1.07695 -0.1576 0% Void, No xenon 4 60 Hot Standby Taoderator=5 F TFuel=546° F 0.85233 1.04807 -0.1868 0% Void, No xenon 4 60 Hot OperatingNoxe mModerator=5 F TFueI=989° F 0.84837 1.04319 -0.1867 0% Void, No xenon 46 Hot Operatingo TModerator=5 ° F TFu 8 1=98 9 0 F 0.84837 1.04319 -0.1867 0% Void 4 60 Hot Operating 4 o TModerator=5 F TFue1=989° F 0.80538 1.02535 -0.2145 40% Void Hot Operating 80 TModerator=5 4 60 F T~uej989 0 F 0.75083 1.00194 -0.2506 80% Void ARE VA Inc.
Docurnen~
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-154 Table 2o159 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D230 Lower Blade BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k) 68 Cold TModerator= ° F TFueI=68° F 0.91325 1.08498 -0.1583 0% Void, No xenon Intermediate TModerator= 2 0 0 0 F TFueI200° F 0.89962 1.07695 -0.1647 0% Void, No xenon 4
Hot Standby T~oderator=5 6° F TFueI=546° F 0.84337 1.04807 -0.1953 0% Void, No xenon Hot OperatingaoxC Taoderator= 5 4 6 0 F T~uel=989° F 0.83945 1.04319 -0.1953 0% Void, NO xenon 4
Hot Operating0 TModerator=5 6° F TFueI=989° F 0.83951 1.04319 -0.1953 0% Void 4
Hot Operating 40 Taoderator=5 6° F TFUeS=989° F 0.79493 1.02535 -0.2247 40% Void 4 60 Hot Operating 80 Tuoderator=5 F TFueI=989° F 0.73833 1.00194 -0.2631 80% Void AREVA Inc.
Contro~ed Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-155 Table 2.160 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D230 Blade Tip BaeWrh=kcontrolled " kuncontrolled kcontrolled kuncontrolled Blade kuncontrolied Worth (Ak/k)
TModerator=6 8 Cold ° F TFueI=68° F 0.91682 1.08498 -0.1550 0% Void, No xenon Intermediate Taoderator=2 0 0 0 F TFueI=200° F 0.90309 1.07695 -0.1614 0% Void, No xenon Hot Standby Taoderator= 5 4 6 0 F TFue1=546° F 0.84689 1.04807 -0.1920 0% Void, No xenon 4 60 Hot OperatingNoxe TModerator=5 F TFueI=989° F 0.84295 1.04319 -0.1920 0% Void, No xenon 4 60 Hot Operatingo TModerator=5 F TFueI=989° F 0.84295 1.04319 -0.1920 0% Void 46 Hot Operating 40 TMederator=5 ° F TFueI=989° F 0.79917 1.02535 -0.2206 40% Void Hot Operating 80 TModerator=5 4 6° F TFueI=989 0 F 0.74379 1.00194 -0.2576 80% Void AREVA Inc.
COfltFCc~C~ Docu~r~ent Nuclear Fuel Design Report AN P-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-156 Table 2.161 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Bottom Segment BaeWrh=kcontrolled - kuncontrojled kcontrolled kuncontrol led Blade kuncontrolled Worth (Ak/k)
Cold TModerator= 6 8 ° F Tiuei-68° F 0.92741 1.08498 -0.1452 0% Void, NO xenon Intermediate TModerator= 2 0 0 ° F TFueI=2 0 00 F 0.91437 1.07695 -0.1510 0% Void, No xenon 46 Hot Standby TModerator=5 ° F TFueZ=546° F 0.86120 1.04807 -0.1783 0% Void, No xenon Hot OperatingNoxe TMederator=5 46
° F TFUe=989 0 F 0.85720 1.04319 -0.1783 0% Void, No xenon Hot Operating 0 TModerator=5 4 6 0 F TFueI=989 0 F 0.85725 1.04319 -0.1782 0% Void 4 60 Hot Operating 4 o TModerator=5 F TFUe0=989° F 0.81609 1.02535 -0.2041 40% Void Hot Operating 8 0 TModerator=5 46
° F Tpuej=989 0 F 0.76405 1.00194 -0.2374 80% Void_____
AREVA Inc.
Contro~led Documen Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-157 Table 2.162 Lattice ( ] Control Blade at BOL for Control Blade Type GE Marathon Blade Main Segment Worths BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade laeWrh= kuncontrolled Worth (Ak/k)
Cold TModerator=6 8 ° F T~uei=680 F 0.92024 1.08498 -0.1518 0% Void, No xenon Intermediate TModerator= 2 0 0 0 F Tpuei=200 0 F 0.90695 1.07695 -0.1578 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFue0 =5460 F 0.85212 1.04807 -0.1870 0% Void, No xenon 4 60 Hot Operatingaox* TModerator=5 F TFueI=9 8 9 0 F 0.84816 1.04319 -0.1870 0% Void, No xenon Hot Operating 0 Taoderator=5 4 6
° F TFueI=98 9 0 F 0.84822 1.04319 -0.1869 0% Void Hot Operating 4 0 mModerator=5 4 6° F TFueC=989 0 F 0.80488 1.02535 -0.2150 40% Void 4 60 Hot Operating 8 0 TModerator=5 F TFueI=98 9 ° F 0.74992 1.00194 -0.2515 80% Void ARE VA Inc.
CX~ntrc~ed Docur2er~t Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-158 Table 2.163 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Main BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k) 80 68 Cold TModerator=6 F TFueI= °F 0.92089 1.08498 -0.1512 0% Void, No xenon Intermediate ,TModerator= 2 0 0 0 F TFUeI=200° F 0.90777 1.07695 -0.1571 0% Void, No xenon Hot Standby TModerator= 5 4 6 0 F TFueI=5 4 6 ° F 0.85368 1.04807 -0.1855 0% Void, No xenon 4 60 Hot OperatingNoxe TModerator=5 F TFueI=989° F 0.84972 1.04319 -0.1855 0% Void, No xenon Hot Operating 0 ITModermtor=5 4 6 ° F TFueI=989 0 F 0.84979 1.04319 -0.1854 0% Void 46 Hot Operating 40 TModerator=5 ° F TFueI=989° F 0.80742 1.02535 -0.2125 40% Void 46 Hot Operating 8 0 mModerator=5 ° F TFue1=989° F 0.75338 1.00194 -0.2481 80% Void AREVA Inc.
Gontroited D ...
n Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-159 Table 2.164 Lattice [ ] Control at BOL for Control Blade Type CR82M1 and CR82B Blade Tip Blade Worths BaeWrh=kcontrolled " kuncontrolIed kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator=6 8° F TFueI=68 0 F 0.94174 1.08498 -0.1320 0% Void, No xenon Intermediate mModerator=2 0 0 0 F TFueI=200° F 0.92939 1.07695 -0.1370 0% Void, No xenon 46 Hot Standby TModerator=5 ° F TFue!=546° F 0.88072 1.04807 -0.1597 0% Void, NO xenon Hot OperatingNoxe TModerator= 5 4 6 ° F TFueI=989° F 0.87658 1.04319 -0.1597 0% Void, No xenon 4 60 Hot Operating 0 TModerator=5 F TFueI=989° F 0.87658 1 .04319 -0.1597 0% Void 46 Hot Operating 4 0 TModertor=5 ° F TFueI=989° F 0.83987 1.02535 -0.1809 40% Void 46 Hot Operating 80 TModerator=5 ° F TFueI=989° F 0.79333 1.00194 -0.2082 80% Void AREVA Inc.
~D~ocurnent Nuclear FuelUnit Design Report ANP-3294NP Quad Cities 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-160 Table 2.165at Lattice [
BOL for Control Blade Type CR99 Blade Tip
] Control Blade Worths kControlled " kuncontrolled kcontrolled kuncontrolled Blade Blade Worth = kuncontrolled Worth
____ ____ ____(Ak/k)
Cold mModerator= 6 8 0 F TFueI=68° F 0.91945 1.08498 -0.1526 0% Void, No xenon Intermediate TModerator= 2 0 0 ° F TFueI=200° F 0.90611 1.07695 -0.1586 0% Void, No xenon Hot Standby mModerator= 5 4 6 0 F TFueI=546° F 0.85106 1.04807 -0.1880 0% Void, No xenon 4
Hot Operatingaoxe. Taoderator=5 6° F Ttuei=989° F 0.84710 1.04319 -0.1880 0% Void, No xenon 46 Hot Operatingo TModeretor=5 ° F Tiuei=989° F 0.84718 1.04319 -0.1879 0% Void 4
Hot Operating 40 T~oderator=5 6° F TFuel=989° F 0.80374 1.02535 -0.2161 40% Void 460 Hot Operating 80 TModerator=5 F TF,,e=989° F 0.74813 1.00194 -0.2533 80% Void_____
AREVA Inc.
C nr~dDocum ent Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-161 Table 2.166 Lattice [ ] Control at BOL for Control Blade Type CR99 Blade Main Blade Worths BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrojied Blade kuncontrolled Worth (Ak~k) 6 80 Cold TModerator=6 8° F TFuel= F 0.91790 1.08498 -0.1540 0% Void, No xenon Intermediate TModerator= 2 0 0 0 F TFueI=2 0 0 ° F 0.90452 1.07695 -0.1601 0% Void, No xenon Hot Standby TModerator=5 46
° F TFuel=5 4 6 ° F 0.84905 1.04807 -0.1899 0% Void, No xenon 4 6 Hot Operatingaoxe TModerator=5 ° F TFUeC=989° F 0.84511 1.04319 -0.1899 0% Void, No xenon 46 Hot Operating 0 T~oderator=5 ° F TFue0=9890 F 0.84519 1.04319 -0.1898 0% Void 46 89 Hot Operating 4 0 TModerator=5 ° F TFuej=9 ° F 0.80125 1.02535 -0.21 86 40% Void Hot Operating 80 Tuoderator=5 46
° F TFueI=989 0 F 0.74494 1.00194 -0.2565 80% Void AREVA Inc.
.ntoLmed~ DocLu ent Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-162 Table 2.167 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD2 BaeWrh=kcontrolled "kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth
____ ____ ____(Ak/k)
Cold TModerator= 6 8 ° F TFUe1=68° F 0.94078 1.08498 -0.1329 0% Void, No xenon Intermediate Taoderator=2 0 0 ° F TFueI=200 0 F 0.92815 1.07695 -0.1382 0% Void, No xenon 46 Hot Standby Taoderator=5 ° F TFueI=546 0 F 0.87752 1.04807 -0.1627 0% Void, No xenon 4
Hot Operatingaoxe TModerator=5 6° F TFuei=989° F 0.87340 1.04319 -0.1628 0% Void, No xenon Hot Operating0 Taoderator=5 4 6 ° F TFueI=989° F 0.87346 1.04319 -0.1627 0% Void 46 Hot Operating 4 o TModerator=5 ° F TFueI=989° F 0.83466 1.02535 -0.1860 40% Void Hot Operating 8 o TMoedratoj=5 4 6 ° F TFueI=989 0 F 0.78509 1.00194 -0.2164 80% Void AREVA Inc.
Cosro~Lbd Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-163 Table 2.168 at BOLLatticefor Control [ ] Control Blade Type GE Marathon Blade Ultra HD3Worths Baekcontrolled " kuncontrolled kcontrojlod kuncontrolled Blade Wrh- kuncontrolled Worth (Aklk) 6 0 Cold TModerator= 8° F TFueI=68 F 0.96313 1.08498 -0.1123 0% Void, No xenon mModerator=2 00 Intermediate ° F TFueI=200° F 0.95123 1.07695 -0.1167 0% Void, NO xenon Hot Standby TModerator= 5 4 6 ° F TFuel=546° F 0.90502 1.04807 -0.1365 0% Void, No xenon 4 60 Hot OperatingNoxe TModerator=5 F TFuei=989° F 0.90073 1.04319 -0.1366 0% Void, No xenon Hot Operating 0 TModerator=5 4 60 F Tiruei=989 0 F 0.90077 1.04319 -0.1365 0% Void Hot Operating 4 0 TModerator= 5 4 6 0 F T~Ue 1=989 0 F 0.86640 1.02535 -0.1550 40% Void Hot Operating 80 TModerator= 5 4 6 0 F TFueI=989° F 0.82203 1.00194 -0.1796 80% Void Table 2.169 Lattice [ ] Kinetics Parameters at BOL Kinetics Kinetics Parameter = r-Pamer kK1 kp (Ak/k)
Dplr= kHotOperatingNoXe - kHotStandby 1.04319 1.04807 -0.0047 Dopper
=kHotStandby Mdatrrd= kHotOperatjng4o - kHotOperating0 1.02535 1.04319 -0.0171 Modertorvid =kwotOperating0 Moeao~meaue= kHotStandby - kcotd 1.04807 1.08498 -0.0340 Modeatorempratue = kcold AREVA Inc.
ont. obe1 Docu;seni Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-164 Table 2.170 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE OEM and D120 BaeWrh=kcontro~jed " kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k) 6 80 Cold TModerator= F TFueI=68 0 F 0.94095 1.09259 -0.1388 0% Void, NO xenon Intermediate TModerator= 2 0 0 ° F TFueI=200° F 0.92801 1.08514 -0.1448 0% Void, No xenon Hot Standby TModermtor5 4 6 0 F TFueI=546° F 0.87659 1.05906 -0.1723 0% Void, No xenon 46 Hot OperatingNoxe TModerator=5 ° F TFueI=989° F 0.87268 1 .05435 -0.1723 0% Void, No xenon 4 6 Hot Operatingo TModerator=5 ° F TFueI=989° F 0.87274 1.05435 -0.1722 0% Void 460 Hot Operating 40 TModerator=5 F TFueI=989 0 F 0.83059 1.03705 -0.1991 40% Void Hot Operating 80 mModerator=5 460 F TFueC=98 9 0 F 0.77362 1.01170 -0.2353 80% Void AREVA Inc.
Contro~ed E~oc~ me ~v Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-165 Table 2.171 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D160 and 0190 Lower Blade BaeWrh=kcontrolled " kuncontrolled kcontrolled kuncontrolled Blade kuncontroijed Worth (Ak/k)
Cold TModerator=6 8 ° F TFueI=68° F 0.93931 1.09259 -0.1403 0% Void, No xenon Intermediate TModerator= 2 0 0 ° F TFuel=200° F 0.92644 1.08514 -0.1462 0% Void, No xenon Hot Standby TModerator=5 4 60 F TFueI=5 4 6 0 F 0.87492 1.05906 -0.1739 0% Void, No xenon Hot OperatingNoxe T~oderator=5 4 6 0 F TFueI=98 9 ° F 0.871 02 1.05435 -0.1739 0% Void, No xenon 460 Hot Operating 0 TModerator=5 F TFue=989° F 0.87107 1.05435 -0.1738 0% Void 46 Hot Operating 40 TModerator=5 ° F TFueI=989° F 0.82826 1.03705 -0.2013 40% Void 4 60 Hot Operating 80 mModerator=5 F TFueI=9890 F 0.77025 1.01170 -0.2387 80% Void AREVA Inc.
CetL Doc m iy*
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-166 Table 2.172 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D190 Blade Tip BaeWrh=kcontrolled " kuncontrolled kcontrolled kUncontrolled Blade kuncontronled Worth (Ak/k)
Cold TModerator=6 8 0 F TFueI=68° F 0.93646 1.09259 -0.1429 0% Void, NO xenon Intermediate TModerator=2 0 0 0 F TFueI=2000 F 0.92339 1.08514 -0.1491 0% Void, No xenon Hot Standby TModerator=5 4 60 F TFueI=546 0 F 0.87026 1 .05906 -0.1783 0% Void, No xenon Hot OperatingNoxe mModerator=5 4 6 ° F TFueI=989° F 0.86639 1.05435 -0.1783 0% Void, NO xenon Hot Operatingo mModerator=5 4 6° F TFueI=989 0 F 0.86639 1.05435 -0.1783 0% Void 46 Hot Operating 40 TModerator=5 ° F TFueI=989° F 0.82195 1.03705 -0.2074
- 40% Void 4 60 Hot Operating 80 mModerator=5 F TFUeI=9 8 9 ° F 0.76166 1.01170 -0.2472 80% Void AREVA Inc.
~tro~ed Document Nuclear Fuel Design Report AN P-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-167 Table 2.173 Lattice [ ] Control BOL for Control Blade Type GE D230 Lower Blade Blade Worths at BaeWrh=kcontraoled " kUncontrolled kcontrorled kuncontrolled Blade kuncontroIled Worth (Ak/k)
Cold TModerator=6 8 ° F TFueI=68° F 0.92948 1.09259 -0.1493 0% Void, NO xenon Intermediate TModerator=2 0 0 0 F TFueI=200° F 0.91619 1.08514 -0.1557 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFueI=5 4 6 ° F 0.86161 1.05906 -0.1864 0% Void, No xenon Hot OperatingNoxe TModerator=5 4 6 0 F TFueI=9 8 9 0 F 0.85779 1.05435 -0.1864 0% Void, No xenon 4 60 Hot Operating 0 TModerator=5 F mFueI=9 8 9 0 F 0.85784 1.05435 -0.1864 0% Void 460 Hot Operating 4 0 TModerator=5 F TFue=989° F 0.81171 1 .03705 -0.2173 40% Void 46 Hot Operating 80 TModerator=5 ° F TFueI=9 8 9 ° F 0.74915 1.01170 -0.2595 80% Void AREVA Inc.
Conro led Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-168 Table 2.174 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D230 Blade Tip BaeW rh= kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade BaeWrh= kuncontrolled Worth
____ ____ ____(Ak/k) 68 Cold TModerator= ° F TF~uel=68° F 0.93284 1.09259 -0.1462 0% Void, No xenon Intermediate TModerator= 2 0 0 0 F TFueI=200° F 0.91949 1.08514 -0.1527 0% Void, No xenon Hot Standby TModerator=5 4 60 F TFuei=5 4 6 ° F 0.86500 1.05906 -0.1832 0% Void, No xenon 460 Hot OperatingNoxe TModerator=5 F TFuej=989° F 0.86116 1.05435 -0.1832 0% Void, No xenon 46 Hot Operatingo TModerator=5 ° F TFueI=989° F 0.86116 1.05435 -0.1832 0% Void Hot Operating 4 o Taoderator=5 46
° F TFueI=989 0 F 0.81585 1 .03705 -0.2133 40% Void 46 Hot Operating 80 T~oderator=5 ° F TFueI=9 8 9 ° F 0.75460 1.01170 -0.2541
- 80% Void AREVA Inc.
QcrVO~ueld DOCL neni Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-169 Table 2.175 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Bottom Segment BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator- 6 80 F TFuel-680 F 0.94290 1.09259 -0.1370 0% Void, NO xenon Intermediate TModerator= 2 0 0 ° F T~ueI=2 0 0 ° F 0.93024 1.08514 -0.1427 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFue0=546° F 0.87892 1.05906 -0.1701 0% Void, No xenon Hot OperatingNoxe TModerator=5 4 G° F TFuel=989° F 0.87502 1.05435 -0.1701 0% Void, No xenon 4 60 Hot Operatingo TModerator=5 F TFuei=989° F 0.87506 1.05435 -0.1701 0% Void 4 60 Hot Operating 40 TModerator=5 F TFu 8 I=989° F 0.83259 1.03705 -0.1972 40% Void 4 60 Hot Operating 8 0 mModerator=5 F TFueI=989° F 0.77497 1.01170 -0.2340 80% Void AREVA Inc.
Contro~ied Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-170 Table 2.176 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Main Segment BaeWrh=kcontrojled "kuncontrolled kControlled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator= 68
° F TFueI=68° F 0.93609 1.09259 -0.1432 0% Void, No xenon Intermediate TModerator=2 0 0 ° F T~uet=2 0 00 F 0.92317 1.08514 -0.1493 0% Void, NO xenon Hot Standby TModerator= 5 4 6 ° F TFueI=546 0 F 0.87009 1.05906 -0.1784 0% Void, No xenon*-
46 Hot Operatingaoxe TModerator=5 ° F TFueI=989° F 0.86624 1.05435 -0.1784 0% Void, No xenon 4 60 Hot Operating 0 TModerator=5 F TFueI=989° F 0.86629 1.05435 -0.1784 0% Void 4 60 Hot Operating 40 TModerator=5 F TFrue1=989° F 0.82 149 1.03705 -0.2079 40% Void 46 Hot Operating 80 TModerator=5 ° F TFue0=989° F 0.76079 1.01170 -0.2480 80% Void AREVA Inc.
Sontro~Ledoue.
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-171 Table 2.177 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Main BaeWrh=kcontrolled - kuncontrolled kcontrolled kunoontrolled Blade kuncontrolled Worth
________________(Ak/k)
Cold TModerator=6 8
° F TFuej=68° F 0.93672 1.09259 -0.1427 0% Void, No xenon Intermediate TModerator= 2 0 0 ° F TFueI=200° F 0.92399 1.08514 -0.1485 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFueI=546° F 0.87174 1.05906 -0.1769 0% Void, No xenon Hot OperatingaoxC T~oderator=5 46
° F TFueI=989° F 0.86787 1 .05435 -0.1769 0% Void, No xenon Hot Operating 0 TModerator=5 460 F TFueI=989 0 F 0.86794 1.05435 -0.1768 0% Void 4 60 Hot Operating 40 TModerator=5 F TFueI=989° F 0.82419 1.03705 -0.2053 40% Void 46 Hot Operating 80 TModerator=5 ° F TFuej=98 9 ° F 0.76439 1.01170 -0.2445 80% Void AREVA Inc.
Corntrolled Dcmn Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-172 Table 2.178 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Tip BaeWrh=kcontroljed "kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k) 68 80 Cold TModerator= ° F TFueI=6 F 0.95628 1.09259 -0.1248 0% Void, NO xenon Intermediate TModerator=2 0 0 0 F TFueI=200° F 0.94433 1.08514 -0.1298 0% Void, No xenon Hot Standby TModerator= 5 4 6 ° F T~uei=546 0 F 0.89756 1 .05906 -0.1525 0% Void, No xenon 4 60 Hot OperatingNoxe TModerator=5 F TFueI=989° F 0.89353 1.05435 -0.1525 0% Void, No xenon 460 Hot Operating 0 TModerator=5 F TF,,eI=989° F 0.89353 1.05435 -0.1525 0% Void 46 Hot Operating 4 0 TModerator=5 ° F TFueI=989° F 0.85577 1.03705 -0.1748 40% Void 460 Hot Operating so TModerator=5 F TFueI=989 0 F 0.80417 1.01170 -0.2051 80% Void AREVA Inc.
C-ortrolled L C Cl Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-173 Table 2.179 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Tip kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade Blade Worth = kuncontrolled Worth
____ ____ ____(Ak/k)
Cold TModerator=6 8 0 F TFueI=68° F 0.93537 1.09259 -0.1439 0% Void, No xenon Intermediate TMederator=2 0 0 0 F TFueI=200° F 0.92238 1.08514 -0.1500 0% Void, No xenon 46 Hot Standby TModerator=5 ° F TFueI=54 6 ° F 0.86912 1.05906 -0.1794 0% Void, NO xenon 46 Hot OperatingNoxe TModerator=5 ° F TFueI=989° F 0.86526 1.05435 -0.1793 0% Void, No xenon 46 Hot Operating 0 Tuoderator=5 ° F TFue1=98 9 ° F 0.86533 1.05435 -0.1793 0% Void Hot Operating 4 0 TModerator=5 46
° F TFuei=989 0 F 0.82050 1.03705 -0.2088 40% Void Hot Operating 8 o TModerator=5 4 6 ° F TFueI=9 8 9 ° F 0.75913 1.01170 -0.2497 80% Void AREVA Inc.
Co t -olled DocL ment Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-174 Table 2.180 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Main BaeWrh kcontrolled " kuncontrolIed kcontrolred kuncontrolled Blade
- kuncontrolled Worth (Ak/k)
Cold TModerator= 6 8 ° F mFueI=68° F 0.93390 1.09259 -0.1452 0% Void, No xenon Intermediate TModerator=2 0 0 0 F TFueI=2 00° F 0.92088 1.08514 -0.1514 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFuel=5460 F 0.86721 1.05906 -0.1812 0% Void, No xenon Hot OperatingNoxe TModerator= 5 4 6 ° F T~uei=989° F 0.86337 1.05435 -0.1811 0% Void, No xenon Hot Operating 0 TModerator=5 4 60 F TFuei=989 0 F 0.86344 1.05435 -0.1811 0% Void 4 60 Hot Operating 40 TModerator=5 F TFueI=989° F 0.81808 1.03705 -0.2112 40% Void Hot Operating80o TModerator=5 46
° F TFuej=989 0 F 0.75594 1.01170 -0.2528 80% Void AREVA Inc.
Cont o~ld Document Nuclear FuelUnit Design Report ANP-3294NP Quad Cities 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-175 Table 2.181 Lattice [ ] Control BOL for Control Blade Type GE Marathon Ultra HD2 Blade Worths at laeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade kuncontroI~ed Worth (Ak/k)
Cold TModerator=6 8 0 F TFueI=6 8° F 0.95559 1.09259 -0.1254 0% Void, No xenon Intermediate TModerater= 2 0 0 ° F TFueI=200° F 0.94335 1.08514 -0.1307 0% Void, No xenon 46 Hot Standby TModerator=5 ° F TFueI=546 0 F 0.89463 1.05906 -0.1553 0% Void, No xenon 4 60 Hot Operatingaoxe T~oderator=5 F TFueI=989 0 F 0.89062 1.05435 -0.1553 0% Void, No xenon 4 60 Hot Operating0 TModerator=5 F TFue1=989° F 0.89067 1.05435 -0.1552 0% Void 4 60 Hot Operating 40 TModerator=5 F TFueI=989° F 0.85079 1 .03705 -0.1796 40% Void 46 Hot Operating 80 T~oderator=5 ° F Truei=989° F 0.79602 1.01170 -0.2132 80% Void AREVA Inc.
~ntroP-~aUocum~n~
Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-176 Table 2.182 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD3 BaeW rh kcontrolled - kuncontrolled kconltrolled kuncontrolled Blade
- kuncontronled Worth (Ak/k)
Cold 68 6 80 TModerator= ° F TFuel= F 0.97669 1.09259 -0.1061 0% Void, No xenon Intermediate TModerator=2 0 0 ° F T~uei=200 0 F 0.96522 1.08514 -0.1105 0% Void, No xenon 46 Hot Standby TModerator=5 ° F TFuel=546° F 0.92106 1.05906 -0.1303 0% Void, No xenon Hot OperatingNoxe TModerator= 5 4 6 ° F TFuej=989° F 0.91690 1.05435 -0.1304 0% Void, No xenon 46 Hot Operating 0 Taoderator=5 ° F TFuei=989° F 0.91694 1.05435 -0.1303 0% Void 460 Hot Operating 40 Taoderator=5 F TF,*e=989° F 0.88186 1.03705 -0,1497 40% Void 4 60 Hot Operating 8 0 TModerator=5 F TFue0=989 0 F 0.83292 1.01170 -0.1767 80% Void Table 2.183 Lattice [ ] Kinetics Parameters at BOL Kinetics Kinetics Parameter =~- aaee k* k* k*(Ak/k)
Dplr kHotOperattngNoxe - kHoeStandby 1.05435 1.05906 -0.0044 Dopper
=kHotStandby Moeaovd= kHotOperating4o - kHotOperatingo 1 .03705 1.05435 -0.0164 Modertorvid =kHotOperating0 kHotStandby"- kcold 1.05906 1.09259 -0.0307 ModeratorTemperature = kcofd AREVA Inc.
C nvciLc Do~rnent Nuclear Fuel Design Report AN P-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page 2-177 Table 2.184 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE OEM and D120 BaeWrh=kcontrolled "kuncontroiled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold TModerator= 6 8 ° F T~uej=68° F 0.94929 1.10181 -0.1384 0% Void, No xenon 2 00 Intermediate TModerator= 2 0 0 ° F TFueI= °F 0.93680 1.09498 -0.1445 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFueI=546 0 F 0.88788 1.07252 -0.1722 0% Void, No xenon Hot OperatingNoxe TModerator= 5 4 6 ° F TFuei=989° F 0.88398 1.06781 -0.1722 0% Void, No xenon Hot Operatingo TModerator=5 4 6 0 F TFueI=989 0 F 0.88404 1.06781 -0.1721 0% Void 46 Hot Operating 4 0 TModerator=5 ° F TFueI=989° F 0.84305 1.05261 -0.1991 40% Void 46 Hot Operating 80 TModerator=5 ° F TFueI=9 8 9 ° F 0.78693 1.02986 -0.2359 80% Void AREVA Inc.
CnoedDocument Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-178 Table 2.185 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE 0160 and D190 Lower Blade BaeWrh=kcontrolled - kuncontrolled koontrolled kuncontrorledj Blade kuncontrolled Worth (Ak/k) 68 0 Cold TModerator= ° F TFueI=68 F 0.94763 1.10181 -0.1399 0% Void, No xenon Intermediate TModerator= 2 0 0 ° F TFueI=200° F 0.93521 1.09498 -0.1459 0% Void, NO xenon 460 Hot Standby TModerator=5 F TFue!=546° F 0.88618 1.07252 -0.1737 0% Void, No xenon_____
546 Hot OperatingNoxe TModerator= ° F TFuei=989° F 0.88228 1.06781 -0.1737 0% Void, NO xenon 46 Hot Operatingo TModerator=5 ° F TFueI=989 0 F 0.88233 1.06781 -0.1737 0% Void 46 Hot Operating 40 TModerator=5 ° F TFueI=989° F 0.84067 1.05261 -0.2014 40% Void 460 Hot Operating 80 TModerator=5 F TFue1=989° F 0.78348 1.02986 -0.2392 80% Void AREVA Inc.
Con tro leJ Docum
', *_ 4 Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-179 Table 2.186 Lattice (
BOL for Control Blade Type GE D190 Blade Tip
] Control Blade Worths at BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Aklk)
Cold TModerator-- 6 8 0 F TFueI=68° F 0.94475 1.10181 -0.1426 0% Void, No xenon ____
0 00 Intermediate TMederator= 2 F TFueI=200° F 0.93213 1.09498 -0.1487 0% Void, No xenon 4 6 Hot Standby TModerator=5 ° F TFu 8 1=546° F 0.88145 1.07252 -0.1782 0% Void, No xenon Hot OperatingNoxe TModerator=5 4 6 ° F TFueI=989° F 0.87759 1.06781 -0.1781 0% Void, No xenon Hot Operating 0 TModer~ator=5 4 6 ° F TFuej=989 0 F 0.87759 1.06781 -0.1781 0% Void Hot Operating 4 o Tuoderator=5 4 6 ° F TFuet=989° F 0.83424 1 .05261 -0.2075 40% Void 46 Hot Oeaig80 TModerator=5 ° F TFuej=989° F 0.77466 1.02986 -0.2478 80% Void AREVA Inc.
Contro~ed Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-180 Table 2.187 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D230 Lower Blade BaeWrh=kcontrolled " kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold mModerator= 6 8 0 F TFueI=68° F 0.93769 1.10181 -0.1489 0% Void, NO xenon Intermediate TModerator=2 0 0 ° F TFueI=200° F 0.92484 1.09498 -0.1554 0% Void, No xenon 4 60 Hot Standby mModerator=5 F TF.I=546° F 0.87266 1.07252 -0.1863 0% Void, No xenon 46 Hot OperatingNoxe TModerator=5 ° F TFuej=989° F 0.86885 1.06781 -0.1863 0% Void, NO xenon 4 60 Hot Operating 0 TModerator=5 F TFueI=989° F 0.86890 1.06781 -0.1863 0% Void Hot Operating 40 TModerator=5 4 6 0 F TFueI=989° F 0.82379 1 .05261 -0.2174 40% Void Hot Operating 80 TModerator=5 460 F TFueI=9 8 9 ° F 0.76186 1.02986 -0.2602 80% Void AREVA Inc.
Con troiled Doci mer Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-181 Table 2.188 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE D230 Blade Tip BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
CdTModerator-68 0F TFueI=68° F 0.94110 1.10181 -0.1459 0% Void, No xenon Intermediate mModerator= 2 00
° F TFueI=2 0 0 0 F 0.92819 1.09498 -0.1523 0% Void, No xenon Hot Standby tModerator=5 4 60 F TFueZ=5 4 6° F 0.87611 1.07252 -0.1831 0% Void, No xenon 4 60 Hot Operatingaoxe T~oderator=5 F Tpuei=989° F 0.87228 1.06781 -0.1831 0% Void, No xenon 4 60 Hot Operatingo TModerator=5 F TFueC=989 0 F 0.87228 1.06781 -0.1831 0% Void 4 60 Hot Operating 40 TModerator=5 F TFue1=989° F 0.82801 1.05261 -0.2134 40% Void Hot Operating 80 TModerator=5 4 60 F TFU8 1=9 8 9 ° F 0.76739 1.02986 -0.2549 80% Void AREVA Inc.
Con~roiled "oumn Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-182 Table 2.189 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Bottom Segment BaeWrh=kcontrolled - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k)
Cold mModerator=6 8 ° F TFueI=68° F 0.95120 1.10181 -~0.1367 0% Void, No xenon Intermediate mModerator=2 0 0 ° F TFueI=200° F 0.93900 1.09498 -0.1424 0% Void, No xenon 4 60 Hot Standby TModerator=5 F TFueI=546 0 F 0.89018 1.07252 -0.1700 0% Void, No xenon Hot OperatingNoxe TModerator=54 6 0 F TFueI=9 8 9 ° F 0.88628 1.06781 -0.1700 0% Void, No xenon Hot Operatingo TModerator=5 4 6 ° F TFueI=9 8 9° F 0.88633 1.06781 -0.1700 0% Void Hot Operating 4 o Taoderator=5 4 6 0 F TFueI=989 0 F 0,84499 1.05261 -0.1972 40% Void 46 Hot Operating 80 TModerator=5 ° F TFuel= 9 8 9 0 F 0.78819 1.02986 -0.2347 80% Void AREVA Inc.
ControIled Dcct °mervL Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-183 Table 2.190 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Blade Main Segment BaeWrh=kcontrolled "kuncontrolled kcontrolled kuncontrolled Blade ldeWrh= kuncontrolled Worth (Ak/k)
Cold TModerator= 6 80 FT~uei=68 0 F 0.94434 1.10181 -0.1429 0% Void, No xenon Intermediate TModerator=2 0 0 ° F TFueI=2 0 0 0 F 0.93188 1.09498 -0.1489 0% Void, No xenon Hot Standby Taodeator=5 46
° F TFueI=546 0 F 0.88126 1.07252 -0.1783 0% Void, No xenon Hot OperatingNoxC TModerator= 5 4 6 ° F TFuei=989 0 F 0.87741 1.06781 -0.1783 0% Void, NO xenon Hot Operating 0 TModerator=5 46
° F TFue!=989 0 F 0.87746 1.06781 -0.1783 0% Void 46 Hot Operating 4 0 Tuoderator=5 ° F TFueI=989° F 0.83374 1 .05261 -0.2079 40% Void 4 60 Hot Operating 80 TModerator=5 F TFueI=9 8 9° F 0.77372 1.02986 -0.2487 80% Void AREVA Inc.
Coflnt olie Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-184 Table 2.191 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Main kcontrolled - kucnrlekonrle kuc told Ba e Blade Worth = Ucnrle kuncontrolled cnrle ucnrle ld Worth (Ak/k) 680 Cold TModerator= F TFuel=68° F 0.94494 1.101 81 -0.1424 0% Void, No xenon Intermediate TModerator=2 0 0 ° F TFue1=200° F 0.93265 1.09498 -0.1482 0% Void, No xenon 46 Hot Standby TModerator=5 ° F TFue1=546° F 0.88283 1.07252 -0.1769 0% Void, No xenon 460 Hot OperatingNexe TModerator=5 F TFueI=989° F 0.87897 1.06781 -0.1769 0% Void, No xenon Hot Operating 0 TModerator=5 4 6 ° F TFueI=989° F 0.87904 1.06781 -0.1768 0% Void 4 60 Hot Operating 4 0 TModerator=5 F TFuel=989° F 0.83637 1.05261 -0.2054 40% Void 46 Hot Operating 680 TModerator=5 ° F TFueI=989° F 0.77730 1.02986 -0.2452 80% Void AREVA Inc.
Control ed Documert Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-185 Table 2.192 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR82M1 and CR82B Blade Tip BaeWrh=kcontrolled "kuncontrolled kcontrojled kuncontrolved Blade kuncontroaled Worth
____ ____ ____(Ak/k)
Cold TModerator=6 8 0 F TF,,ej=68° F 0.96474 1.10181 -0.1244 0% Void, NO xenon Intermediate TModerator= 2 0 0 0 F TFuej-200 0 F 0.95325 1.09498 -0.1294 0% Void, No xenon 46 1.07252 -0.1524 Hot Standby TModerator=5 ° F TFuel=546° F 0.90910 0% Void, No xenon 460 Hot OperatingNoxe TModerator=5 F TFueI=989 0 F 0.90507 1.06781 -0.1524 0% Void, No xenon 460 Hot Operating 0 TModerator=5 F TFueI=989 0 F 0.90507 1.06781 -0.1524 0% Void 460 Hot Operating 40 TModerator=5 F TFueI=989 0 F 0.86861 1.05261 -0.1748 40% Void Hot Operating 80 TModerator=5 46 ° F TFuej=9 8 9 ° F 0.81810 1.02986 -0.2056 80% Void AREVA Inc.
Cotholed Documnt Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 10XM Fuel Page 2-186 Table 2.193 Lattice [ ] Control Blade Worths at BOL for Control Blade Type CR99 Blade Tip BaeWrh=kcontrolled - kuncontrolled kcontrolled ku ncontronled B lade kuncontrolied Worth (Akdk)
Cold TModerator= 6 8 ° F TFuei=68 0 F 0.94362 1.101 81 -0.1436 0% Void, No xenon Intermediate mModerator=2 0 00 F TF,,e=200° F 0.931 09 1.09498 -0.1497 0% Void, No xenon Hot Standby mModerator=5 46
° F TFuej=54 6 ° F 0.88025 1.07252 -0.1793 0% Void, No xenon 4 60 Hot OperatingNoxe TModerator=5 F TFueI=9890 F 0.87640 1.06781 -0.1792 0% Void, No xenon Hot Operating 0 T~oderator=5 4 6 ° F TFuej=9 8 9 ° F 0.87647 1.06781 -0.1792 0% Void Hot Operating 4 0 TModerator=5 4 6 ° F TFueI= 9 9 8 °F 0.83273 1.05261 -0.2089 40% Void 46 9 89 Hot Operating 80 mModerator=5 ° F TFueI= ° F 0.77207 1.02986 -0.2503 80% Void AREVA Inc.
Contro~led Docume nt Nuclear FuelUnit Design Report ANP-3294NP Quad Cities 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-187 Table 2.194 Lattice [ ] Control Blade BOL for Control Blade Type CR99 Blade Main Worths at BaeWrh=kcontrojled - kuncontrolled kcontrolled kuncontrolled Blade kuncontroiled Worth
_______(Ak/k) 68 Cold TModeratar= ° F TFueI=68° F 0.94214 1.10181 -0.1449 0% Void, No xenon Intermediate mModerator= 2 0 0 0 F TFuei=200° F 0.92956 1.09498 -0.1511 0% Void, No xenon 46 Hot Standby mModerator=5 ° F TFuei=546° F 0.87831 1.07252 -0.1811 0% Void, No xenon Hot OperatingNoxe TModerator-' 46
° F TFueI=9 8 9° F 0.87447 1.06781 -0.1811 0% Void, No xenon 4 60 Hot Operating 0 TModerator=5 F TFueI=989° F 0.87454 1.06781 -0.1810 0% Void 46 Hot Operating 40 Tioderator=5 ° F TFueI=989° F 0.83025 1.05261 -0.2112 40% Void 460 Hot Operating 8 0 Taoderator=5 F TFueI=989° F 0.76880 1.02986 -0.2535 80% Void AREVA Inc.
Co~nt oi[ed Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-188 Table 2.195 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon Ultra HD2 Bld oh=kcontrojled - kuncontrolled kcontrolled kuncontrolled Blade kuncontrolled Worth (Ak/k) 6 80 68 Cold Tacderator= F TFueI= °F 0.96406 1.101 81 -0.1250 0% Void, No xenon Intermediate TModerator= 2 0 0 ° F TFueI=200° F 0.95230 1.09498 -0.1303 0% Void, No xenon Hot Standby TModerator=5 4 6 ° F TFueI=546° F 0.90620 1.07252 -0.1551 0% Void, No xenon Hot OperatingNoxe TModerator=5 46
° F TFueI=9 89° F 0.90220 1.06781 -0.1551 0% Void, No xenon 46 Hot Operating 0 TModerator=5 ° F TFuel=989° F 0.90226 1.06781 -0.1550 0% Void Hot Operating 4 0 TModerator=5 46
° F TFueI=989 0 F 0.86365 1.05261 -0.1795 40% Void 46 Hot Operating 80 TModerator=5 ° F TFueI=989° F 0.80990 1.02986 -0.2136 80% Void AREVA Inc.
Cmtonb ld Documernt Nuclear FuelUnit Design Report ANP-3294NP Quad Cities 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-189 Table 2.196 Lattice [
BOL for Control Blade Type GE Marathon Ultra HD3
] Control Blade Worths at BaeWrh=kcontrojled - kuncontrolled kcontrogled kuncontrolled B lade kuncontrolled Worth (Ak/k) 68 Cold TModerator-- ° F TFuej=68° F 0.98540 1.10181 -0.1056 0% Void, No xenon Intermediate TModerator=2 0 0 0 F TFueI=200° F 0.97444 1.09498 -0.1101 0% Void, No xenon Hot Standby TModerator= 5 4 6 ° F TFueI=546° F 0.93309 1.07252 -0.1300 0% Void, No xenon 4 60 Hot OperatingNox* TModerator=5 F TFueI=989° F 0.92892 1.06781 -0.1301 0% Void, No xenon Hot Operating 0 TModerator= 5 4 6 ° F TFueI=989° F 0.92897 1.06781 -0.1300 0% Void Hot Operating 40 TModerater=5 4 6 ° F TFueI=989° F 0.89537 1.05261 -0.1494 40% Void 4 60 Hot Operating 8 0 TModerator=5 F TFuei=989° F 0.84782 1.02986 -0.1768 80% Void Table 2.197 Lattice [ ] Kinetics Parameters at BOL Kinetics Kinetics Parameter=ka- k kp k, k*(Ak/k) aaee Dplr- kHotOperatingNoXe - kHotStanldby1.68 1075 -. 04 Dopper
=kHotStandby Mdatrld= kHotaperating40 - kHotOperatingo 1.05261 1.06781 -0.0142 Modertorvid =kHotOperatingo Mdatrepmue-kHotStandby - kCold 1 .07252 1.10181 -0.0266 Modeatorempratue = kcold AREVA Inc.
Controlled Document Nuclear Fuel Design Report Quad Cities Unit 2 Cycle 24 APage2-90N Representative Cycle ATRIUM 10XM Fuel Page 2-190
[
I Figure 2.1 Assembly Type [ I AREVA Inc.
Controlled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-191 r
I Figure 2.2 Assembly Type [ I AREVA Inc.
Controlled Docum~ent Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM I0XM Fuel Page 2-192
[
]
Figure 2.3 Assembly Type [
AREVA Inc.
SonrVoIlt Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-193 1L 1 2 3 4 5 6 5 4 3 7 2 4 5 8 9 8 9 8 10 3 3 5 9 9 11 9 11 9 8 6 4 8 9 12 9 9 9 8 9 10 5 9 11 9 11 8 10 6 8 9 9 Water Channel 10 9 10 5 9 11 9 11 8 10 4 8 9 8 11 10 11 9 10 6 3 10 8 9 8 9 8 10 12 4 7 3 6 10 10 10 10 6 4 7 Fuel Rod Type Quantity Fuel Rod Type Quantity 1 1 7 3 2 2 8 14 3 6 9 22 4 7 10 14 5 6 11 8 6 6 12 2 Figure 2.4 [ ] Fuel Rod Distribution AREVA Inc.
Controlled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-194 IL 1 2 3 4 5 5 5 4 3 7 2 4 13 9 9 13 9 13 10 3 3 13 10 9 11 9 11 9 13 5 4 9 9 5 9 9 9 10 9 10 5 9 11 9 11 13 10 5 13 9 9 Water Channel 10 9 10 5 9 11 9 11 13 10 4 13 9 10 11 10 11 9 10 10 3 10 13 9 13 9 13 10 13 4 7 3 5 10 10 10 10 10 4 7 Fuel Rod Type Quatity Fuel Rod Type Quantity 1 1 7 3 2 2 9 23 3 6 10 19 4 7 11 8 5 9 13 13 Figure 2.5 [ ] Fuel Rod Distribution AREVA Inc.
Cont.roled~ Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-195
/L
,< I 1 2 3 4 6 6 6 5 3 7 2 3 5 13 9 13 9 13 10 4 3 5 10 9 11 9 11 9 13 6 4 13 9 5 9 9 9 10 9 10 6 9 11 9 11 13 10 6 13 9 9 Water Channel 10 9 10 6 9 11 9 11 13 10 5 13 9 10 11 10 11 9 10 6 3 10 13 9 13 9 13 10 9 4 7 4 6 10 10 10 10 6 4 7 Fuel Rod Type Quantity Fuel Rod Type Quantity 1 1 7 3 2 2 9 22 3 5 10 17 4 6 11 8 5 5 13 12 6 10 Figure 2.6 [ ] Fuel Rod Distribution AREVA Inc.
Controled Docume nt Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 2-196 C
Figure 2.7 Fuel Rod Axial Description
]
AREVA Inc.
Cont oiled Doc~ument Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 3-1 3.0 References
- 1. EMF-93-1 77(P)(A) Revision 1, Mechanical Design for BWR Fuel Channels, Framatome ANP, August 2005.
- 2. ANF-89-98(P)(A) Revision 1 and Supplement 1, Generic Mechanical Design Criteriafor BWR Fuel Designs, Advanced Nuclear Fuels Corporation, May 1995.
- 3. EMF-21 58(P)(A) Revision 0, Siemens Power CorporationMethodology for Boiling Water Reactors: Evaluation and Validation of CASMO-4/MICROBURN-B2, Siemens Power Corporation, October 1999.
AREVA Inc.
Controlied Do~cument Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 10XM Fuel Page A-I Appendix A Enriched Lattice Hot Uncontrolled Reactivity and LPF Plots The results in this appendix are based on hot operating and equilibrium xenon conditions.
AREVA Inc.
Contro~led Document Nuclear Fuel Design Report Quad Cities Unit 2 Cycle 24 APage A-2 Representative Cycle ATRIUM 10XM Fuel Page A-2 1.26 1.21 1.16 I.II 2
1.06 e.
C 1.01 0.91 0.86 0.81 0.76 0I10 20 30 40 50 60 70 Lattice Exposure (GWd/MTU)
Figure A.1 [ ] Hot Uncontrolled k,.
1.39
' .34
- 1.29 a
j 1.24 0
1.09 0 10 2.0 30 40 50 60 70 Lattice Expos ure (GWd/MTU)
Figure A.2 [ ] Hot Uncontrolled LPF AREVA Inc.
Controlled Docu ment Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page A-3 1.21 1.16 I.II
-* 1.06 2 1.01 u 0.96 S0.91 0.86 0.8!
0.76 010 20 30 40 50 60 70 Lattice Expos ure (GWdIMTU)
Figure A.3 [ ] Hot Uncontrolled IK I0
'*1.35 C
"* 1.30
'U
-* 1.25 8
-J
"*1.20 t- 1.15 0
U I.0 I .05 0I10 20 30 40 50 60 70 Lattice Expos u re (GWdIMTU)
Figure A.4 [ ] Hot Uncontrolled LPF AREVA Inc.
Contro led Docurnent Nuclear Fuel Design Report AN P-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page A-4 1.21 1.16 I.II 1.06 "2
1.01 0o0.96 Ui~
0 0.91 0.86 0.81 0.76 0.71 0 020 30 40 50 60 70 Lattice Exposure (GWdIMTU)
Figure A.5 [ ] Hot Uncontrolled k.
1.29 S1.34
'* 1.29 0.
- i1.24 e- 1.14 0
U S1.09 1.04 10 20 30 40 50 60 70 Lattice Expos ure (GWdIMTU)
Figure A.6 [ ] Hot Uncontrolled LPF AREVA Inc.
Contrrolled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page A-5 1.20 1.15 1.10
.05
--- 1.00 C0.95 0
- 0.90
- 0.85 0.80 0.75 0.70 0 0 20 30 40 50 60 70 Lattice Expos ure (GWd/MTU)
Figure A.7 [ ] Hot Uncontrolled 1.45 03
- c 1.40 c 1.30
- 1.30
- 1.20 0
1.105 0 10 20 30 40 50 60 70
- Lattice Expos ure (GWdIMTU)
Figure A.8 [ ] Hot Uncontrolled LPF AREVA Inc.
Controlled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page A-6 1.20 1.15 1.10 1.05 "2
1.00 0o 0.95 0
0.90 0}
0.85 0.80 0.75 0.70 10 20 30 40 50 60 70 Lattice Exposure (GWdlMTU)
Figure A.9 [ ] Hot Uncontrolled k,.
1.40 "61.35 U.-
.* 1.30
(.
8
- 1.20
- 31.10 I .05 0 10 20 30 40 50 60 70 Lattice Expos ure (GWd/MTU)
Figure A.10 [ ] Hot Uncontrolled LPF AREVA Inc.
CotroIled Document Nuclear FuelUnit Design Report ANP-3294NP Quad Cities 2 Cycle 24 Revision 1 Representative Cycle ATRIUM I0XM Fuel Page A-7 1.30 1.20 "0 1.10 c 1.00 S0.90 0.80 0.70 I10 20 30 40 50 60 70 Lattice Expos ure (GWd/MTU)
Figure A.11 [ ] Hot Uncontrolled k*,
1.39 L1.4
- 1.29 a.
j1.24
-J "I 1.9 e- 1.14 0
0
"*1.09 1.04 1020 30 40 50 60 70 Lattice Expos ure (GWdlMTU)
Figure A.12 [ ] Hot Uncontrolled LPF AREVA inc.
Controlled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page A-8 1.21 1.16 I.I "o 1.06 0 1.01 Oo 0.96 S0.91 0.86 0.81 0.76 0 10 20 30 40 50 60 70 Lattice Exposure (GWdlMTU)
Figure A.13 [ ] Hot Uncontrolled k=
1.34 1.29 C
o31.24 8 1.19 c-
".. 1.14 S1.09 I0 20 30 40 50 60 70 Lattice Expos ure (GWdlMTU)
Figure A.14 [ ] Hot Uncontrolled LPF AREVA Inc.
Controlled Document Nuclear Fuel Design Report Quad Cities Unit 2 Cycle 24 APage A-9 Representative Cycle ATRIUM 10XM Fuel Page A-9 1.21 1.16 I.II 21.06
= 1.01 S0.9
- -0.86 0.81 0.76 0.71 0I0 20 30 40 50 60 70 Lattice Exposure (GWdlMTU)
Figure A.15 [ ] Hot Uncontrolled k*
1.34 1.29 a, --------------------------------------- 0%
1.24 1 1.19
"-,x ....... 80 2 1.14 0
- 1.09 1.04 0 10 20 30 40 50 60 70 Lattice Exposure (GWdlMTU)
Figure A.16 [ ] Hot Uncontrolled LPF AREVA Inc.
Cont olkea Do . .mnent Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page A-10 1.30 1.20
- 1.10 C- 1.00 0
U 0.80 0.70 0 10 20 30 40 50 60 70 Lattice Expos ure (GWdlMTU)
Figure A.17 [ ] Hot Uncontrolled k,.
1.39 1L.2
-I
". 1.29 0~
,- 1.24 8
e-,
C 1.14 1.09 0 I10 20 30 40 50 60 70 Lattice Expos ure (GWdlMTU)
Figure A.18 [ ] Hot Uncontrolled LPF AREVA Inc.
Controlled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page A-11 1.30 1.20 13 1.10 0
-0.90 0.80 0.70 0I0 20 30 40 50 60 70 Lattice Exposure (GWdlMTU)
Figure A.19 [ ] Hot Uncontrolled k*
1 39
' .34
"* 1.29
"* 1.24 r-11.9
.04 10 20 30 40 50 60 70 Lattice Expos ure (GWdlMTU)
Figure A.20 [ ] Hot Uncontrolled LPF AREVA Inc.
Controlled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 10XM Fuel Page A-12 1.21 1.16 S1.01 o 0.%
S 0.91 0.86 0.81 0.76 0I10 2.0 30 40 50 60 70 Lattice Expos ure (GWd/MTU)
Figure A.21 [ 1 Hot Uncontrolled k=,
1.34 1.29 e=1.24
- 1.19
-JLI 0
2: 1.04 S1.09 10 20 30 40 50 60 70 Lattice Expos ure (GWdIMTU)
Figure A.22 [ 1 Hot Uncontrolled LPF AREVA Inc.
Controlled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page A-13 1.21 1.16 I.II
,. I.01 0*
S0.91
.*0.86 0.81 0.76 0.71 I0 20 30 40 50 60 70 Lattice Expos ure (GWdlMTU)
Figure A.23 [ ] Hot Uncontrolled k,.
1.34 1.29 1.24 a,
- 1.19 I, 1.14 0-U
- 1.09 1.04 0 I0 20 30 40 50 60 70 Lattice Exposure (GWd/MTU)
Figure A.24 [ ] Hot Uncontrolled LPF AREVA Inc.
Contro~led Docu ment Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page A-14 1.30 1.2.0
- 1.10
,- 1.00 0.8 0.70 0I0 20 30 40 50 60 70 Lattice Exposure (GWdlMTU)
Figure A.25 [ ] Hot Uncontrolledk, 1.39 1.34 Lu.
'* 1.29 Cu S1.24 8
"1.14 0
C
" 1.09 1.04 1020 30 40 50 60 70 Lattice Expos ure (GWdIMTU)
Figure A.26 [ ] Hot Uncontrolled LPF AREVA Inc.
Controlied Documnent Nuclear Fuel Design Report AN P-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page A-15 1.30 1.20
.oi
,-" 1.10 0
- 0.90 0.80 0.70 I10 20 30 40 50 60 70 Lattice Expos ure (GWd/MTU)
Figure A.27 [ ] Hot Uncontrolled k,.
1.39
.34 Cu LL.
-* 1.29 0~
-r" 1.04 10 20 30 40 50 60 70 Lattice Expos ure (GWdIMTU)
Figure A.28 [ ] Hot Uncontrolled LPF AREVA Inc.
Controte Doc~ument Nuclear Fuel Unit Quad Cities Design Report AN P-3294N P 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page B-i Appendix B Enriched Lattice Hot Uncontrolled Reactivity and LPF Tables The results in this appendix are based on hot operating and equilibrium xenon conditions.
AREVA Inc.
Controlted Dlocument Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page B-2 Table B.1 J Hot Uncontrolled k=
Exposure 0.00 Void 0.40 Void 0.80 Void MWd/MT0U History History History
- 0. 1.03648 1.02078 1.00157 100. 1.01611 1.00216 0.88536 500. 1.01579 1.00267 0.88676 1000. 1.01818 1.00660 0.99102 1500. 1.02374 1.01142 0.88580 2000. 1.02865 1.01648 1.00063 2500. 1.03371 1.02158 1.00537 3000. 1.03888 1.02668 1.00888 3500. 1.04422 1.03184 1.01454 4000. 1.04876 1.03706 1.01905 4500. 1.05552 1.04238 1.02355 5000. 1.06153 1.04786 1.02806 5600. 1.06777 1.05346 1.03262 6000. 1.07417 1.05816 1.03721 6500. 1.08063 1.06481 1.04185 7000. 1.08707 1.07064 1.04650 7500. 1.08345 1.07630 1.05113 8000. 1.08878 1.08180 1.05572 8500. 1.10608 1.08747 1.06026 8000. 1.11235 1.08300 1.06474 8500. 1.11864 1.098852 1.06818 10000. 1.12502 1.10405 1.07358 10500. 1.13155 1.10864 1.07785 11000. 1.13828 1.11531 1.08228 11500. 1.14526 1.12108 1.08663 12000. 1.15242 1.12686 1.08086 12500. 1.15868 1.13288 1.08528 13000. 1.16683 1.13873 1.08854 13500. 1.17358 1.14438 1.10370 14000. 1.17874 1.14863 1.10768 14500. 1.18488 1.15434 1.11138 15000. 1.18815 1.16833 1.11474 15500. 1.18205 1.16152 1.11766 16000. 1.18363 1.16378 1.12008 16500. 1.18382 1.16510 1.12186 17000. 1.18304 1.16546 1.12322 17500. 1.18115 1.16484 1.12386 18000. 1.18846 1.16361 1.12388 18500. 1.16515 1.16158 1.12334 18000. 1.18141 1.15801 1.12225 18500. 1.17735 1.165898 1.12068 20000. 1.17308 1.15260 1.11868 20500. 1.16853 1.14887 1.11634 21000. 1.16387 1.14517 1.11368 21500. 1.15840 1.14124 1.11077 22000. 1.15484 1.13724 1.10767 22500. 1.15028 1.13313 1.10441 23000. 1.14571 1.12801 1.10105 23500. 1.14114 1.12488 1.08761 24000. 1.13656 1.12076 1.08411 24500. 1.13188 1.11664 1.08058 25000. 1.12742 1.11252 1.08700 27500. 1.10448 1.08218 1.06821 30000. 1.08148 1.07206 1.05177 32500. 1.05840 1.05211 1.03471 35000. 1.03523 1.03234 1.01802 37600. 1.01201 1.01277 1.00173 40000. 0.88880 0.58343 0.88582 42500. 0.86568 0.87436 0.87034 45000. 0.84274 0.85561 0.85530 47500. 0.82011 0.83724 0.84072 50000. 0.589782 0.81830 0.52665 52500. 0.87636 0.50187 0.81310 55000. 0.85558 0.88502 0.80008 57500. 0.83576 0.86885 0.88763 60000. 0.81708 0.86342 0.87575 62500. 0.75867 0.83878 0.56446 65000. 0.78366 0.82503 0.85377 67500. 0.76814 0.81218 0.54368 70000. 0.75613 0.80028 0.83421 AREVA Inc.
Contro led Document Nuclear FuelUnit Design Report ANP-3294NP Quad Cities 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page B-3 Table B.2
] Hot Uncontrolled LPF Exposure 0.00 Void 0.40 Void 0.80 Void M~fd/M'1U History History History
- 0. 1.366 1.351 1.325 100. 1.369 1.345 1.315 500. 1.351 1.337 1.306 1000. 1.341 1.329 1.300 1500. 1.330 1.319 1.293 2000. 1.319 1.309 1.285 2500. 1.307 1.299 1.278 3000. 1.295 1.289 1.270 3500. 1.263 1.279 1.262 4000. 1.274 1.269 1.255 4500. 1.266 1.260 1.247 5000. 1.258 1.253 1.242 5500. 1.250 1.246 1.237 6000. 1.242 1.239 1.232 6500. 1.234 1.232 1.226 7000. 1.228 1.225 1.221 7500. 1.223 1.219 1.218 8000. 1.216 1.213 1.211 5500. 1.209 1.207 1.207 9000. 1.201 1.201 1.202 5500. 1.193 1.196 1.198 10000. 1.187 1.191 1.193 10500. 1.161 1.185 1.189 11000. 1.175 1.180 1.185 11500. 1.169 1.175 1.181 12000. 1.163 1.170 1.176 12500. 1.157 1.165 1.172 13000. 1.151 1.160 1.168 13500. 1.145 1.155 1.164 14000. 1.139 1.149 1.160 14500. 1.134 1.145 1.156 15000. 1.128 1.140 1.152 15500. 1.123 1.135 1.149 16000. 1.119 1.131 1.145 16500. 1.115 1.127 1.141 17000. 1.111 1.123 1.138 17500. 1.108 1.120 1.135 18000. 1.106 1.117 1.132 18500. 1.103 1.114 1.129 19000. 1.101 1.112 1.126 19500. 1.099 1.110 1.124 20000. 1.098 1.108 1.122 20500. 1.097 1.106 1.120 21000. 1.095 1.105 1.118 21500. 1.094 1.103 1.117 22000. 1.092 1.102 1.116 22500. 1.091 1.100 1.114 23000. 1.090 1.099 1.113 23500. 1.090 1.097 1.112 24000. 1.089 1.096 1.11i 24500. 1.089 1.094 1.110 25000. 1.088 1.093 1.109 27500. 1.084 1.085 1.103 30000. 1.081 1.080 1.098 32500. 1.076 1.077 1.092 35000. 1.072 1.074 1.087 37500. 1.067 1.071 1.082 40000. 1.063 1.068 1.077 42500. 1.069 1.064 1.073 45000. 1.055 1.060 1.089 47500. 1.055 1.058 1.088 50000. 1.055 1.055 1.066 52500. 1.054 1.052 1.076 55000. 1.052 1.050 1.088 57500. 1.049 1.048 1.100 80000. 1.044 1.046 1.113 62500. 1.037 1.058 1.126 65000. 1.058 1.075 1.139 67500. 1.079 1.092 1.151 70000. 1.088 1.108 1.163 AREVA Inc.
Controiled Docume~nt Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 1OXM Fuel Page B-4 Table 6.3 ] Hot Uncontrolled k*
Exposure 0.00 Void 0.40 Void 0.80 Void MWd/54TU History History History
- 0. 1.02242 1.00489 0.98363 100. 1.00211 0.98635 0.96753 500. 1.00101 0.98616 0.96831 1000. 1.00325 0.98906 0.97171 1500. 1.00647 0.99271 0.97555 2000. 1.01003 0.99656 0.97941 2500. 1.01373 1.00045 0.98319 3000. 1.01748 1.00430 0.98684 3500. 1.02132 1.00813 0.99036 4000. 1.02629 1.01200 0.99386 4500. 1.02940 1.01591 0.99730 5000. 1.03366 1.01988 1.00071 5500. 1.03806 1.02392 1.00413 6000. 1.04257 1.02602 1.00755 6500. 1.04708 1.03214 1.01098 7000. 1.05153 1.03622 1.01441 7500. 1.05586 1.04021 1.01781 8000. 1.06008 1.04409 1.02116 8500. 1.06409 1.04788 1.02443 9000. 1.06800 1.05156 1.02763 9500. 1.07181 1.05515 1.03075 10000. 1.07559 1.05868 1.03380 10500. 1.07938 1.06217 1.03677 11000. 1.08322 1.05566 1.03869 11500. 1.08712 1.06918 1.04256 12000. 1.09112 1.07273 1.04541 12500. 1.09525 1.07634 1.04825 13000. 1.09955 1.08004 1.05109 13500. 1.10406 1.08384 1.05395 14000. 1.10683 1.08777 1.05684 14500. 1.11389 1.09185 1.05978 15000. 1.11923 1.09609 1.06278 15500. 1.12481 1.10050 1.06583 16000. 1.13056 1.10501 1.06892 16500. 1.13632 1.10955 1.07205 17000. 1.14186 1.11399 1.07515 17500. 1.14694 1.11824 1.07818 18000. 1.15139 1.12215 1.08107 16500. 1.15497 1.12556 1.08376 19000. 1.15752 1.12836 1.08621 19500. 1.15895 1.13045 1.08834 20000. 1.15924 1.13178 1.09008 20500. 1.15847 1.13232 1.09139 21000. 1.15675 1.13206 1.09222 21500. 1.15425 1.03107 1.09257 22000. 1.15114 1.12940 1.09242 22500. 1.14754 1.12717 1.09179 23000. 1.14360 1.12447 1.09069 23500. 1.13943 1.12139 1.08918 24000. 1.13491 1.11802 1.06729 24500. 1.13040 1.11443 1.08507 25000. 1.12588 1.11068 1.09257 25500. 1.12132 1.10682 1.07984 28000. 1.11676 1.10278 1.07691 26500. 1.11219 1.09875 1.07383 27000. 1.10762 1.09471 1.07063 27500. 1.10307 1.09068 1.06736 26000. 1.09850 1.08668 1.06402 28500. 1.09393 1.08268 1.06065 30000. 1.06021 1.07069 1.05032 32500. 1.05727 1.05086 1.03340 35000. 1.03427 1.03123 1.01682 37500. 1.01122 1.01179 1.00062 40000. 0.98818 0.99259 0.98481 42500. 0.96521 0.97365 0.96941 45000. 0.94242 0.95501 0.95446 47500. 0.91991 0.93674 0.93996 50000. 0.89782 0.91890 0.92596 52500. 0.87633 0.90154 0.91246 55000. 0.85559 0.88476 0.89949 57500. 0.83578 0.56862 0.88707 60000. 0.81707 0.85320 0.87521 62500. 0.79960 0.83856 0.86393 65000. 0.78351 0.62478 0.85324 67500. 0.76867 0.81188 0.84314 70000. 0.75573 0.79992 0.83365 AREVA Inc.
Controlled Docurnent Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page B-5 Table B.4 [ ] Hot Uncontrolled LPF Exposure 0.00 Void 0.40 Void 0.80 Void MWd/HTU History History History
- 0. 1.378 1.363 1.337 100. 1.371 1.357 1.328 500. 1.383 1.350 1.318 1000. 1 .354 1.342 1.312 1500. 1.344 1.333 1.306 2000. 1.334 0.324 1.299 2500. 1.323 1.315 1.292 3000. 1.312 1.306 1.285 3500. 1.301 1.296 1.278 4000. 1.290 1.287 1.271 4500. 1.279 1.278 1.264 5000. 1 .270 1.2688 1 .257 5500. 1.263 1.259 1.250 6000. 1.258 1.251 1.243 6500. 1.256 1.245 1.238 7000. 1.252 1.239 1 .233 7500. 1.248 1.234 1.229 8000. 1.243 1.228 1.224 9500. 1 .237 1.223 1.220 9000. 1.230 1.218 1.216 9500. 1.223 1.213 1.212 10000. 1.217 1.208 1.208 10500. 1.209 1.204 1.204 11000. 1 .202 1.199 1.200 11500. 1 .195 1.195 1.197 12000. 1 .188 1.190 1.193 12500. 1 .182 1.186 1.189 13000. 1.177 1.181 1.186 13500. 1.171 1.177 1.182 14000. 1.166 1.173 1.179 14500. 1.161 1.168 1.175 15000. 1.155 1.164 1.172 15500. 1.150 1.159 1.168 18000. 1.144 1.154 1.165 18500. 1 .139 1.150 1.161 17000. 1 .123 1.145 1.158 17500. 1.128 1.140 1.154 18000. 1.122 1.136 1.151 18500. 1.117 1.131 1.147 19000. 1.112 1.127 1.144 18500. 1.108 1.122 1.140 20000. 1.103 1.118 1.137 20500. 1.100 1.114 1.133 21000. 1.096 1.111 1.130 21500. 1.093 1.108 1.127 22000. 1.092 1.105 1.124 22500. 1.091 1.102 1.121 23000. 1.091 1.100 1.119 23500. 1.090 1.097 1.116 24000. 1.089 1.095 1.114 24500. 1.089 1.094 1.112 25000. 1.088 1.092 1.111 25500. 1.087 1.090 1.109 28000. 1.087 1.089 1.107 26500. 1.086 1.087 1.108 27000. 1.086 1.086 1.105 27500. 1.085 1.084 1.104 28000. 1.084 1.083 1.102 28500. 1.083 1.083 1.101 30000. 1.081 1.081 1.098 22500. 1.077 1.078 2.093 35000. 1.073 1.075 1.087 37500. 1.088 1.072 1.082 40000. 1. 064 1.069 1.078 42500. 1. 060 1.066 1.073 45000. 1. 061 1.062 1.071 47500. 1.082 1.060 1.070 50000. 1.062 1.057 1.068 92500. 2. 062 1. 054 1.075 55000. 1.061 1.052 1.087 57500. 1.057 1.050 1.1I00 60000. 1.052 1.048 1.113 62500. 1.045 1.057 1.125 65000. 1.057 1.074 1.138 67500. 1.078 1.091 1.151 70000. 1.098 1.108 1.163 AREVA Inc.
ControI'ed Docrnent Nuclear Fuel Design Report Quad Cities Unit 2 Cycle 24 AP-ge94NP Representative Cycle ATRIUM 1OXM Fuel Page B-6 Table B.5
] Hot Uncontrolled koo Exposure 0.00 Void 0.40 Void 0.80 Void MWd/MTU History History History
- 0. 0.95554 0.94208 0.92519 100. 0.93632 0.52444 0. 90974 500. 0.93616 0.92526 0.91159 1000. 0.93967 0.92956 0.91650 1500. 0.94433 0.93478 0.92201 2000. 0.94944 0.94032 0.92765 2500. 0.95475 0.94595 0.93325 3000. 0.96021 0.95150 0.93876 3500. 0.96559 0.95735 0.54421 4000. 0.97151 0.96321 0.94965 4500. 0.97797 0.96921 0. 95510 5000. 0.95437 0.97533 0.96057 5500. 0.99093 0.95154 0.96607 6000. 0.99750 0.98777 0. 97155 6500. 1.00395 0. 99391 0. 97704 7000. 1.01024 0.99993 0.98243 7500. 1. 01534 1.00580 0.95771 8000. 1.02225 1.01152 0.99289 5500. 1 .02502 1.01711 0.99797 9000. 1.03372 1.02260 1.00294 9500. 1.03942 1.02505 1.00783 10000. 1.04515 1.03350 1.01265 10500. 1.05102 1.03900 1 .01744 11000. 1.05699 1.04457 1.02220 11500. 1.05312 1.05023 1.02698 12000. 1. 06945 1.05601 1.03179 12500. 1.07614 1.06198 1.03664 13000. 1.08314 1.05510 1.04156 13500. 1.09054 1.07450 1. 04 658 14000. 1.09839 1.08118 1.05171 14500. 1.10667 1.08816 1.05698 15000. 1.11520 1.09536 1.06239 15500. 1.12378 1.10267 1.06789 16000. 1.13212 1.10987 1.07343 16500. 1.13984 1.11676 1.07887 17000. 1. 14 664 1.12309 1 .05410 17500. 1.15211 1.12564 1.08900 15000. 1.15600 1.13318 1.09343 18500. 1.15827 1.13650 1.09725 19000. 1.15892 1.13856 1.10039 19500. 1.15809 1.13938 1.10259 20000. 1.15599 1.13903 1.10415 20500. 1.15292 1.13766 1.10475 21000. 1.14917 1.13542 1.10460 21500. 1.14461 1.13252 1.10369 22000. 1.14006 1.12912 1.10213 22500. 1.13550 1.12535 1.10002 23000. 1.13068 1.12114 1.09747 23500. 1.12557 1.11690 1.09456 24000. 1.12105 1.11267 1.09139 24500. 1. 11524 1.10843 1.08802 25000. 1.11142 1.10419 1.08453 27500. 1.08705 1.08276 1.06603 30000. 1.06241 1.08128 1.04765 32500. 1.03745 1.03953 1.02950 35000. 1.01215 1.01839 1.01162 37500. 0.98665 0.99698 0. 99403 40000. 0.96095 0.97564 0.97573 42500. 0.93520 0.95443 0.95976 45000. 0. 90954 0.93344 0.94315 47500. 0.55417 0.91275 0.92696 50000. 0.85935 0.59247 0.91124 52500. 0.83534 0.57274 0.89601 55000. 0.81241 0.55369 0.88133 57500. 0.79084 0.83547 0.86724 60000. 0.77089 0.51520 0.85378 52500. 0.75274 0.80200 0.84100 55000. 0.73652 0.78695 0. 828 93 67500. 0.72229 0.77320 0.51758 70000. 0.70999 0.76070 0.80700 AREVA Inc.
o, ton oled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM IOXM Fuel Page B-7 Table B.6
] Hot Uncontrolled LPF Exposure 0.00 Void 0.40 Void 0.80 Void M4Wd/MTU History History History
- 0. 1.349 1.323 1.297 100. 1.345 1.320 1.293 500. 1.337 1.315 1.286 1000. 1.328 1.309 1.261 1500. 1.316 1.300 1.274 2000. 1.302 1.290 1.268 2500. 1.291 1.279 1.261 3000. 1.281 1.269 1.253 3500. 1.271 1.260 1.246 4000. 1.263 1.252 1.239 4500. 1.263 1.243 1.232 5000. 1.262 1.237 1.226 5500. 1.261 1.235 1.219 6000. 1.258 1.232 1.212 6500. 1.253 1.226 1.206 7000. 1.246 1.223 1.199 7500. 1.237 1.216 1.193 8000. 1.227 1.208 1.187 8500. 1.217 1.200 1.182 9000. 1.209 1.191 1.176 5500. 1.200 1.192 1.171 10000. 1.192 1.175 1.165 10500. 1.184 1.168 1.160 11000. 1.176 1.161 1.155 11500. 1.168 1.154 1.150 12000. 1.164 1.147 1.145 12500. 1.160 1.140 1.140 13000. 1.156 1.137 1.136 13500. 1.153 1.134 1.131 14000. 1.149 1.131 1.126 14500. 1.145 1.128 1.121 15000. 1.140 1.125 1.117 15500. 1.136 1.122 1.112 10000. 1.132 1.119 1.107 15500. 1.127 1.116 1.103 17000. 1.123 1.113 1.101 17500. 1.116 1.111 1.100 18000. 1.115 1.108 1.099 18500. 1.111 1.106 1.098 19000. 1.108 1.104 1.097 19500. 1.106 1.102 1.096 20000. 1.104 1.1I00 1.096 20500. 1.102 1.099 1.095 21000. 1.101 1.098 1.095 21500. 1.100 1.097 1.094 22000. 1.098 1.096 1.094 22500. 1.097 1.095 1.094 23000. 1.096 1.094 1.093 23500. 1.094 1.093 1.093 24000. 1.093 1.093 1.093 24500. 1.091 1.092 1.093 25000. 1.090 1.091 1.092 27500. 1.084 1.087 1.091 30000. 1.078 1.083 1.099 32500. 1.074 1.080 1.089 35000. 1.073 1.076 1.096 37500. 1.073 1.072 1.084 40000. 1.078 1.071 1.083 42500. 1.063 1.071 1.082 45000. 1.066 1.070 1.080 47500. 1.066 1.069 1.079 50000. 1.065 1.068 1.078 52500. 1.082 1.066 1.077 55000. 1.076 1.064 1.076 57500. 1.069 1.061 1.075 60000. 1.060 1.058 1.075 62500. 1.050 1.055 1.074 69000. 1.042 1.053 1.074 67500. 1.044 1.054 1.074 70000. 1.059 1.055 1.074 AREVA Inc.
Controlled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page B-8 Table B.7
] Hot Uncontrolled k=
Exposure 0.00 Void 0.40 Void 0.80 Void MWd/MTUJ History History History
- 0. 0.96226 0.94979 0.93242 100. 0.94267 0.93178 0.91672 500. 0.94237 0.93251 0.91854 1000. 0.94585 0.93683 0.92353 1500. 0.95056 0.94217 0.92917 2000. 0.95578 0.94787 0.93457 2500. 0.96123 0.95370 0.94076 2000. 0.96689 0.95960 0.94647 3000. 0.97281 0.96563 0.95215 4000. 0.97901 0.97181 0.95783 4500. 0.96051 0.97816 0.96353 5000. 0.99228 0.98466 0.96927 5500. 0.99924 0.99127 0.97508 6000. 1.00619 0.99789 0.98083 6500. 1.01302 1.00441 0.98656 7000. 1.01965 1.01079 0.99221 7500. 1.02604 1.01701 0.98774 6000. 1.03220 1.02305 1.00318 6600. 1.03820 1.02885 1.00849 9000. 1.04414 1.03474 1.01371 9500. 1.05009 1.04050 1.01883 10000. 1.05612 1.04629 1.02390 10500. 1.06226 1.05213 1.02893 11000. 1.06856 1.05807 1.03396 11500. 1.07509 1.06413 1.03901 12000. 1.08190 1.07034 1.04411 12500. 1.08907 1.07677 1.04926 13000. 1.09666 1.08344 1.05450 13500. 1.10474 1.09043 1.05985 14000. 1.11331 1.09776 1.06538 14500. 1.12232 1.10542 1.07101 15000. 1.13159 1.11332 1.07662 15500. 1.140988 1.12132 1.08274 16000. 1.14960 1.12014 1.08869 16500. 1.15794 1.13656 1.09451 17000. 1.16462 1.14328 1.10008 17500. 1.17012 1.14899 1.10526 16000. 1.17364 1.15341 1.10989 16500. 1.17527 1.15641 1.11382 19000. 1.17509 1.15800 1.11690 19500. 1.17332 1.15822 1.11909 20000. 1.17037 1.15717 1.12033 20500. 1.16660 1.15507 1.12067 21000. 1.16194 1.15215 1.12018 21500. 1.15707 1.14866 1.11893 22000. 1.15231 1.14454 1.11702 22500. 1.14755 1.14042 1.11458 23000. 1.14255 1.13601 1.11172 23500. 1.13755 1.13160 1.10854 24000. 1.13256 1.12718 1.10514 24500. 1.12786 1.12277 1.10158 25000. 1.12256 1.11836 1.09786 27500. 1.09716 1.09611 1.07884 30000. 1.07132 1.07378 1.06003 32500. 1.04502 1.05137 1.04144 35000. 1.01628 1.02888 1.02308 37500. 0.99113 1.00633 1.00500 40000. 0.96369 0.98376 0.98717 42500. 0.93609 0.96126 0.96965 45000. 0.90854 0.93890 0.95247 47500. 0.86129 0.91682 0.93570 50000. 0.65465 0.89515 0.91937 52500. 0.62896 0.87405 0.90354 55000. 0.80458 0.85371 0.88827 57500. 0.781866 0.83429 0.87359 60000. 0.76111 0.81597 0.85958 62500. 0.74253 0.79891 0.84626 65000. 0.72623 0.78321 0.83369 67500. 0.71222 0.76896 0.82180 70000. 0.70038 0.75519 0.81082 AREVA Inc.
Controdled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page B-9 Table B.8 i ] Hot Uncontrolled LPF Exposure 0.00 Void 0.40 Void o.8o Void llWd/MTU3 History History History
- 0. 1 .385 1.317 1.286 100. 1 .387 1.314 1.279 500. 1.384 1.308 1.274 1000. 1.380 1.302 1.268 1500. 1.375 1.296 1.261 2000. 1.369 1.282 1.255 2500. 1.363 1.288 1.248 3000. 1 .357 1.284 1.241 3500. 1.351 1.280 1. 235 4000. 1 .345 1.275 1 .228 4500. 1.338 1.271 1. 221 5000. 1.331 1.265 1.214 5500. 1.324 1.261 1.208 6000. 1.317 1.256 1.201 6600. 1 .310 1.251 1.185 7000. 1.303 1.246 1.188 7500. 1.296 1.241 1.182 8000. 1.288 1.236 1.176 8500. 1.283 1.232 1.171 8000. 1.276 1.227 1.165 5500. 1.270 1.222 1.160 10000. 1.263 1.218 1 .154 10500. 1.257 1.213 1 .152 11000. 1.250 1.208 1.149 11500. 1.244 1.204 1.147 12000. 1.238 1.188 1.145 12500. 1.231 1.195 1.142 13000. 1.225 1.181 1.140 13500. 1.218 1.186 1.137 14000. 1.212 1.181 1.135 14500. 1.205 1.177 1.133 15000. 1.198 1.172 1.130 15500. 1.190 1.167 1 .128 16000. 1.183 1.162 1.126 16500. 1.175 1.157 1.124 17000. 1.168 1.153 1.122 17500. 1.161 1.148 1.120 18000. 1.155 1.144 1.118 18500. 1.148 1.140 1.117 18000. 1.145 1.137 1.115 18500. 1.141 1.134 1.114 20000. 1.137 1.131 1.113 20500. 1.134 1.129 1.112 21000. 1.132 1.126 1.111 21500. 1.129 1.125 1 .111 22000. 1.126 1.123 1 .110 22500. 1.124 1.121 1.108 22000. 1.121 1.118 1.108 23500. 1.119 1.118 1.108 24000. 1.116 1.116 1.107 24500. 1.114 1.125 1.107 25000. 1.111 1.113 1.106 27500. 1.089 1.105 1.104 20000. 1.090 1.0988 1.101 32500. 1.085 1 .081 1.0988 35000. 1.081 1.084 1 .095 37500. 1.086 1.079 1. 083 40000. 1.0980 1.078 1. 081 42500. 1.093 1.077 1.089 45000. 1.094 1.075 1. 087 47500. 1.083 1.073 1.085 50000. 1.080 1.070 1. 083 52500. 1.085 1.068 1.082 55000. 1.078 1.065 1.081 57500. 1.069 1.062 1.080 60000. 1.058 1.060 1.078 62500. 1.047 1.057 1.079 65000. 1.051 1.087 1.079 87500. 1.058 1.060 1.079 70000. 1.065 1 .064 1.080 AREVA Inc.
Controlled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page B-10 Table B.9 ] Hot Uncontrolled IK Exposure 0.00 Void 0.40 Void 0.80 Void O4Wd/MTU1 History History History
- 0. 1 .00810 0.88281 0.87082 100. 0.88616 0.87266 0.85317 500. 0.88403 0.87158 0.85334 1000. 0.988530 0.87376 0.85642 1500. 0.88770 0.87690 0.86014 2000. 0.88046 0.88030 0.96400 2500. 0.88330 0.88372 0.96778 3000. 0 .88618 0.88711 0.987145 3500. 0.88816 0.99051 0.987502 4000. 1 .00228 0.883988 0.87856 4500. 1 .00558 0.88754 0.88210 5000. 1 .00807 1.00124 0.88567 5500. 1 .01278 1.00510 0.989830 6000. 1.01674 1.00813 0.88302 6500. 1.02083 1.01335 0.88683 7000. 1.02533 1.01773 1.00076 7500. 1.02880 1.02226 1.00478 8000. 1.03466 1.02682 1.00880 8500. 1.03858 1.03171 1.01310 8000. 1.04473 1.03663 1.01737 9500. 1 .05008 1.04171 1.02173 10000. 1 .05567 1.04686 1.02618 10500. 1 .08150 1.05238 1.03071 11000. 1 .06758 1.05801 1.03534 11500. 1.07386 1.06384 1.04007 12000. 1.08067 1.069888 1.04481 12500. 1.08776 1.07618 1.04886 13000. 1.08527 1.08277 1.06484 13500. 1.10324 1.08868 1.06017 14000. 1. 11168 1.08683 1.06557 14500. 1.12054 1.10451 1.07116 15000. 1.12862 1.11233 1.07682 15500. 1.13878 1.12025 1.08281 16000. 1.14770 1.12800 1.08873 16500. 1.10588 1.13542 1.08455 17000. 1.16283 1.14220 1. 10013 17500. 1.16853 1.14804 1.10532 18000. 1 .17244 1.15264 1.10888 18500. 1 .17452 1.15588 1.11388 18000. 1.17477 1.15772 1.11717 18500. 1.17338 1.15818 1.11843 20000. 1.17070 1.15738 1.12076 20500. 1.16711 1.15548 1.12118 21000. 1.16282 1.15272 1.12077 21500. 1 .15807 1.14833 1.11960 22000. 1.15321 1.14526 1.11776 22500. 1.14836 1.14118 1 .11537 23000. 1.14333 1.13677 1 .11254 23500. 1.13830 1.13235 1 .10838 24000. 1.13328 1.12784 1.10589 24500. 1.12825 1.12352 1.10244 25000. 1.12322 1.11811 1.08872 27500. 1.08775 1.08682 1.07867 30000. 1 .07186 1.07443 1.06081 32500. 1 .04551 1.05187 1.04217 35000. 1 .01871 1.02942 1.02377 37500. 0.998151 1.00681 1.00562 40000. 0.986401 0.98420 0.88775 42500. 0.983637 0.86164 0.87018 45000. 0.980877 0.83925 0.85287 47500. 0.88148 0.81712 0.93616 50000. 0.85482 0.88542 0.81880 52500. 0.82812 0.87430 0.80384 55000. 0.80474 0.85384 0.88864 57500. 0.78204 0.83451 0.87385 60000. 0.76130 0.81620 0.85882 62500. 0.74275 0.78814 0.84 658 65000. 0.72648 0.78345 0.83402 67500. 0.71251 0.76823 0.82223 70000. 0.70071 0.75649 0.81125 AREVA Inc.
Controled Cocwnent Nuclear Fuel Design Report ANP-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page B-11 Table B.1O0 ] Hot Uncontrolled LPF Exposure 0.00 Void 0.40 Void 0.80 Void MWd/MTU History History History
- 0. 1.379 1.333 1.251 100. 1.376 1.330 1.249 500. 1.370 1.326 1.247 1000. 1.363 1.321 1.244 1500. 1.355 1.314 1.241 2000. 1.347 1.308 1.237 2500. 1.342 1.300 1.233 2000. 1.338 1.293 1.228 3500. 1.333 1.285 1.223 4000. 1.329 1 .277 1.218 4500. 1.324 1.269 1.213 5000. 1.320 1.260 1.207 5500. 1.315 1.252 1.202 6000. 1.310 1.249 1.186 6500. 1.305 1.245 1.190 7000. 1.300 1.242 1.184 7500. 1.294 1.238 1.178 8000. 1.289 1.234 1.172 8500. 1.283 1.230 1.168 9000. 1.277 1.226 1.163 9500. 1.271 1.222 1.159 10000. 1.266 1.218 1.154 10500. 1.259 1.214 1.151 11000. 1.253 1.210 1.148 11500. 1.247 1.206 1.147 12000. 1.241 1.201 1.145 12500. 1.235 1.197 1.142 13000. 1.228 1.193 1.140 13500. 1.222 1 .188 1.138 14000. 1.215 1.194 1.136 14500. 1.208 1.179 1.133 15000. 1 .201 1.174 1.131 15500. 1.194 1.169 1.129 16000. 1.186 1.164 1.127 16500. 1.178 1.159 1.124 17000. 1.171 1.154 1.122 17500. 1.163 1.150 1.121 18000. 1.157 1.145 1.119 18500. 1.151 1.141 1.117 19000. 1.146 1.138 1.116 19500. 1 .142 1.135 1.114 20000. 1.139 1.132 1.113 20500. 1.135 1.129 1.112 21000. 1.132 1.127 1.111 21500. 1.130 1.125 1.110 22000. 1.127 1.123 1.110 22500. 1.125 1.122 1.109 23000. 1.122 1.120 1.108 23500. 1 .120 1.119 1.108 24000. 1.117 1.117 1.107 24500. 1.115 1.116 1.107 25000. 1 .112 1.114 1.106 27500. 1.100 1.106 1.103 30000. 1.089 1.0988 1.101 32500. 1.085 1 .091 1. 099 35000. 1.082 0.084 1. 085 37500. 1.097 1.080 1.093 40000. 1.092 1.079 1.090 42500. 1.095 1.077 1.088 45000. 1.096 1.079 1. 086 47500. 1.095 1.073 1.085 50000. 1.052 1.071 1. 083 52500. 1.087 1.0688 1.081 55000. 1.079 1.065 1.080 57500. 1.070 1.063 1. 079 60000. 1.059 1.060 1.079 62800. 1.048 1.057 1. 078 65000. 1 .051 1.057 1.079 67500. 1 .058 1.060 1.079 70000. 1.065 1.063 1.078 AREVA Inc.
Contro'I ed Doc~ument Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page B-12 Table B.11[
Exposure 0.00 Void 0.40 Void J Hot Uncontrolled 0.80 Void ko MWd/MTU History History History
- 0. 1.05813 1.04960 1.03566 100. 1.03629 1.02933 1.01773 500. 1.03515 1.03295 1.02196 1000. 1.04786 1.04213 1.03091 1500. 1.05648 1.05293 1.04105 2000. 1.06993 1.06437 1.05157 2500. 1.08214 1.07633 1.06227 3000. 1.09513 1.08879 1.07314 3500. 1.10891 1.10179 1.08423 4000. 1.12353 1.11533 1.09555 4500. 1.13907 1.12946 1.10713 5000. 1.15555 1.14421 1.11898 5500. 1.17289 1.15853 1.13106 6000. 1.19077 1.17519 1.14329 6500. 1.20852 1.19074 1.15545 7000. 1.22512 1.20948 1.16720 7500. 1.23956 1.21861 1.17806 8000. 1.25117 1.22955 1.18757 6500. 1.25976 1.23805 1.19544 9000. 1.26544 1.24412 1.20157 9500. 1.26833 1.24787 1.20599 10000. 1.26885 1.24950 1.20879 10500. 1.26750 1.24934 1.21010 11000. 1.26463 1.24773 1.21010 11500. 1.26127 1.24507 1.20901 12000. 1.25715 1.24169 1.20701 12500. 1.25269 1.23781 1.20431 13000. 1.24778 1.23363 1.20111 13500. 1.24268 1.22907 1.19754 14000. 1.23797 1.22451 1.19373 14500. 1.23307 1.21995 1.18975 15000. 1.22815 1.21538 1.18568 15500. 1.22324 1.21061 1.18155 17500. 1.20354 1.19247 1.16473 20000. 1.17873 1.15969 1.14414 22500. 1.15363 1.14698 1.12398 25000. 1.12813 1.12427 1.10419 27500. 1.10220 1.10150 1.08468 30000. 1.07578 1.07865 1.06543 32500. 1.04888 1.05571 1.04640 35000. 1.02154 1.03268 1.02761 37500. 0.99379 1.00960 1.00908 40000. 0.96576 0.98653 0.99084 42500. 0.93763 0.96354 0.97292 45000. 0.90962 0.94075 0.95540 47500. 0.88200 0.91829 0.53531 50000. 0.85511 0.89632 0.92172 52500. 0.82933 0.87502 0.90567 55000. 0.80500 0.85457 0.88022 57500. 0.78249 0.83515 0.87543 60000. 0.76207 0.81894 0.86136 62500. 0.74394 0.80007 0.84805 65000. 0.72815 0.78466 0.83554 67500. 0.71467 0.77076 0.82386 70000. 0.70335 0.75839 0.81303 AREVA Inc.
Controlled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM IOXM Fuel Page B-13 Table B.12[
] Hot Uncontrolled LPF Exposure 0.00 Void 0.40 Void 0.80 Void MWd/MTU History History History
- 0. 1.344 1.293 1.218 100. 1.346 1.289 1.215 500. 1.341 1.281 1.209 1000. 1.335 1.270 1.202 1500. 1.328 1.259 1.195 2000. 1.321 1.253 1.188 2500. 1.313 1.248 1.181 3000. 1.306 1.242 1.173 3500. 1.298 1.236 1.166 4000. 1.289 1.230 1.159 4500. 1.281 1.224 1.151 5000. 1.272 1.218 1.146 5500. 1.263 1.212 1.142 6000. 1.254 1.205 1.140 6500. 1.245 1.199 1.136 7000. 1.235 1.192 1.133 7500. 1.227 1.186 1.130 8000. 1.218 1.181 1.128 8500. 1.211 1.176 1.126 9000. 1.205 1.171 1.122 5500. 1.199 1.167 1.122 10000. 1.195 1.164 1.120 10500. 1.191 1.161 1.119 11000. 1.187 1.159 1.118 11500. 1.184 1.156 1.116 12000. 1.181 1.154 1.116 12500. 1.179 1.153 1.115 13000. 1.176 1.151 1.114 13500. 1.174 1.150 1.113 14000. 1.171 1.148 1.113 14500. 1.159 1.146 1.112 15000. 1.156 1.145 1.111 15500. 1.183 1.143 1.111 17500. 1.153 1.137 1.108 10000. 1.140 1.128 1.106 22500. 1.127 1.120 1.103 25000. 1.114 1.112 1.100 27500. 1.101 1.104 1.097 30000. 1.091 1.096 1.094 32500. 1.085 1.088 1.091 35000. 1.080 1.081 1.089 37500. 1.074 1.074 1.086 40000. 1.070 1.072 1.084 42500. 1.070 0.070 1.082 45000. 1.071 1.068 1.080 47500. 1.070 1.066 1.078 50000. 1.067 1.062 1.076 52500. 1.062 1.060 1.075 55000. 1.055 1.057 1.074 57500. 1.046 1.054 1.073 60000. 1.039 1.051 1.072 62500. 1.040 1.049 1.072 65000. 1.047 1.052 1.072 87500. 1.053 1.055 1.072 70000. 1.060 1.058 1.073 AREVA Inc.
Controlled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 1OXM Fuel Page B-14 Table B.13[
] Hot UncontrolledK Exposure 0.00 Void 0.40 Void 0.80 Void MWd/bMTU History History History
- 0. 1.06567 1.04412 1.01855 100. 1.04363 1.02395 1.00093 500. 1.04128 1.02259 1.00065 1000. 1.04211 1.02420 1.00282 1500. 1.04396 1.02566 1.00575 2000. 1.04615 1.02931 1.00867 2500. 2.04836 1.03194 1.01146 3000. 1.05053 1.03447 1.01409 3500. 1.05273 1.03693 1.01658 4000. 1.05499 1.03940 1.018899 4000. 1.05732 1.04187 1.02135 5000. 1.05974 1.04439 1.02369 5500. 1.06227 1.04696 1.02602 6000. 1.06492 1.04961 1.02835 6500. 1.06771 1.05236 1.03075 7000. 1.07065 1.05521 1.03318 7500. 1.07371 1.05815 1.03572 6000. 1.076899 1.06117 1.03830 6500. 1.08018 1.06428 1.04094 9000. 1.08360 1.06746 1.04362 9500. 1.05715 1.07074 1.04635 10000. 1.09084 1.07412 1.04913 10500. 1.09470 1.07762 1.05196 11000. 1.09672 1.08123 1.05464 11500. 1.10293 1.08497 1.05778 12000. 1.10733 1.08884 1.06078 12500. 1.11193 1.09285 1.06385 13000. 1.11677 1.09702 1.06699 13000. 1.12187 1.10134 1.07018 14000. 1.12726 1.10580 1.07344 14500. 1.13291 1.11039 1.07675 15000. 1.13565 1.11503 1.08005 15500. 1.14442 1.11964 1.08332 16000. 1.15008 1.12415 1.08648 16500. 1.15544 1.12643 1.08953 17000. 1.16025 1.13240 1.09241 17500. 1.16425 1.13590 1.09508 19000. 1.16726 1.13881 1.09746 19500. 1.16920 1.14104 1.09949 19000. 1.17007 1.14252 1.10112 19500. 1.16983 1.14319 1.10232 20000. 1.16852 1.14308 1.10306 20500. 1.15625 1.14221 1.10331 21000. 1.16322 1.14064 1.10306 21500. 1.15962 1.13843 1.10233 22000. 1.15564 1.13569 1.10112 22500. 1.15133 1.13253 1.09949 23000. 1.14579 1.12907 1.09749 23500. 1.14224 1.12538 1.09516 24000. 1.13770 1.12139 1.09255 24500. 1.13315 1.11740 1.08971 25000. 1.12881 1.11341 1.08668 25500. 1.12404 1.10937 1.09351 26000. 1.11947 1.10533 1.08024 26500. 1.11491 1.10129 1.07689 27000. 1.21034 1.09725 1.07349 27500. 1.10577 1.09321 1.07001 30000. 1.08283 1.07313 1.06268 32500. 1.05981 1.05323 1.03566 35000. 1.03671 1.03351 1.01900 37500. 1.01356 1.01399 1.00272 40000. 0.99042 0.99469 0.98684 42500. 0.96734 0.97565 0.97136 45000. 0.94443 0.95692 0.95632 47500. 0.92180 0.93856 0.94175 50000. 0.89960 0.92062 0.92766 52500. 0.97798 0.90317 0.91408 55000. 0.85713 0.88629 0.90105 57500. 0.83721 0.87006 0.88857 60000. 0.81839 0.85456 0.87665 62500. 0.80084 0.83985 0.86531 65000. 0.78466 0.82600 0.85456 67500. 0.76996 0.81309 0.84442 70000. 0.75677 0.80104 0.83488 AREVA Inc.
ControIIed Docurnent Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM IOXM Fuel Page B-15 Table B.14 [ ] Hot Uncontrolled LPF Exposure 0.00 Void 0.40 Void 0.80 Void M~d/KiTU History History History
- 0. 1.301 1.286 1.272 100. 1.298 1.295 1.271 500. 1.294 1.292 1.269 1000. 1.290 1.288 1.267 1500. 1.285 1 .283 1.264 2000. 1.279 1.278 1.260 2500. 1.274 1 .272 1.256 3000. 1.269 1.266 1.252 3500. 1.263 1.260 1.247 4000. 1.257 1.254 1.243 4500. 1.252 1.248 1.238 5000. 1.246 1.242 1 .233 5500. 1.240 1.235 1.228 6000. 1.234 1.228 1.223 6500. 1.226 1.222 1.218 7000. 1.222 1.215 1.212 7500. 1.216 1.210 1.207 8000. 1.209 1.204 1.202 5500. 1.203 1.199 1.196 9000. 1.199 1.194 1.191 9500. 1.195 1.188 1.185 10000. 1.192 1.183 1.180 10500. 1.168 1 .177 1.176 11000. 1.184 1 .172 1.172 11500. 1.180 1.166 1.187 12000. 1.176 1 .161 1.163 12500. 1.172 1.156 1.159 13000. 1.168 1 .152 1.155 13500. 1.163 1 .149 1.151 14000. 1.109 1 .145 1.147 14500. 1 .155 1.141 1.143 15000. 1.150 1.138 1.139 15500. 1.146 1.134 1.135 16000. 1.142 1 .131 1.131 16500. 1.138 1.128 1.126 17000. 1.134 1 .125 1.122 17500. 1.131 1.122 1.118 15000. 1.127 1.120 1.114 18500. 1.124 1 .117 1.110 19000. 1.121 1.115 1.107 19500. 1.119 1.113 1.104 20000. 1.117 1.112 1.101 20500. 1.115 1.110 1.099 21000. 1.114 1 .109 1.097 21500. 1.113 1 .107 1.097 22000. 1.111 1.108 1.096 22500. 1.110 1 .105 1.095 23000. 1.109 1 .104 1.095 23500. 1 .108 1 .103 1.094 24000. 1.107 1 .102 1.094 24500. 1.106 1 .102 1.093 25000. 1 .105 1 .101 1.093 25500. 1.104 1.100 1.093 26000. 1.103 1 .099 1.092 26500. 1.101 1.098 1.092 27000. 1.100 1 .097 1.091 27500. 1.099 1 .096 1.091 30000. 1.092 1.091 1.088 32500. 1.086 1 .087 1.086 35000. 1.079 1 .082 1.083 37500. 1.072 1.077 1.080 40000. 1.068 1.072 1.078 42500. 1.063 1. 067 1.075 45000. 1 .058 1.064 1.073 47500. 1.054 1.061 1.070 50000. 1.052 1 .058 1.068 52500. 1.051 1.055 1.074 55000. 1.049 1.053 1.088 57500. 1.046 1 .050 1.099 50000. 1 .042 1.047 1.112 62500. 1.036 1.056 1.124 65000. 1.056 1 .073 1.137 67500. 1.077 1 .090 1.150 70000. 1.097 1.107 1.162 AREVA Inc.
Con troH ed Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page B-16 Table B.15[ ] Hot Uncontrolled k*
Exposure 0.00 Void 0.40 Void 0.80 Void MWd/MTU History History History
- 0. 1.00503 0.98706 0.96512 100. 0.96380 0.96752 0.94789 500. 0.98222 0.96700 0.94853 1000. 0.98408 0.96979 0.95212 1500. 0.98711 0.97357 0.95643 2000. 0.99050 0.97762 0.960899 2500. 0.99394 0.98169 0.96525 3000. 0.99742 0.98563 0.96948 3500. 1.00101 0.98963 0.97357 4000. 1.00473 0.99368 0.97764 4500. 1.00860 0.99781 0.98171 9000. 1.01264 1.00205 0.98579 5500. 1.01686 1.00641 0.98991 6000. 1.02127 1.01091 0.99410 5500. 1.02587 1.01566 0.99836 7000. 1.03064 1.02035 1.00273 7900. 1.03559 1.02526 1.00718 8000. 1.04068 1.03028 1.01171 8500. 1.04595 1.03542 1.01630 9000. 1.05139 1.04067 1.02097 9500. 1.05703 1.04606 1.02571 10000. 1.06287 1.05161 1.03053 10500. 1.06894 1.05732 1.03544 11000. 1.07526 1.06322 1.04044 11500. 1.08185 1.06932 1.04554 12000. 1.08873 1.07563 1.05079 12500. 1.09597 1.08216 1.05607 13000. 1.10365 1.08896 1.06152 12500. 1.11177 1.08605 1.06709 14000. 1.12028 1.10338 1.07275 14500. 1.12898 1.11079 1.07845 15000. 1.13765 1.11815 1.08410 15500. 1.14603 1.12529 1.08960 18000. 1.15261 1.13199 1.09488 16500. 1.15999 1.13793 1.09963 17000. 1.16487 1.14286 1.10432 17500. 1.16611 1.14661 1.10821 18000. 1.16970 1.14913 1.11136 18900. 1.16967 1.15541 1.11369 19000. 1.16820 1.15048 1.11518 19500. 1.16558 1.14943 1.11583 20000. 1.16212 1.14740 1.11570 20500. 1.15811 1.14461 1.11484 21000. 1.15342 1.14126 1.11330 21500. 1.14873 1.13754 1.11119 22000. 1.14404 1.13339 1.15859 22500. 1.13935 1.12925 1.10563 23000. 1.13453 1.12494 1.10239 23500. 1.12970 1.12064 1.09896 25000. 1.11523 1.10772 1.08789 27900. 1.09083 1.08619 1.06924 30000. 1.06613 1.06467 1.05076 32500. 1.04111 1.04314 1.03254 35000. 1.01576 1.02162 1.01459 37500. 0.99014 1.00012 0.99690 40000. 0.96433 0.97869 0.97951 42500. 0.93845 0.99738 0.96244 45000. 0.91264 0.93627 0.94573 47500. 0.88712 0.91545 0.92945 50000. 0.86213 0.89505 0.91362 52500. 0.83793 0.57519 0.89829 55000. 0.81482 0.85600 0.88351 57500. 0.79307 0.83765 0.86932 60000. 0.77293 0.82025 0.85977 62500. 0.75462 0.50392 0.84290 65000. 0.73828 0.78878 0.83073 67500. 0.72388 0.77489 0.81931 70000. 0.71147 0.76230 0.80865 AREVA Inc.
Controfled Docurnent Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 1OXM Fuei Page B-17 Table B.16[ ] Hot Uncontrolled LPF Exposure 0.00 Void 0.40 Void 0.80 Void MWd/MTU History History History
- 0. 1 .302 1.291 1.268 100. 1.299 1.287 1.265 500. 1.294 1.282 1.261 1000. 1.288 1.276 1.256 1500. 1.282 1.270 1.251 2000. 1. 275 1.264 1.245 2500. 1.268 1.257 1.240 3000. 1 .362 1.251 1.234 3500. 1 .255 1.244 1 .229 4000. 1.248 1.238 1 .224 4500. 1.241 1.231 1.219 5000. 1.233 1.225 1.214 5500. 1.226 1.218 1.208 6000. 1.218 1.211 1.203 6500. 1.211 1.204 1.198 7000. 1 .203 1.197 1.193 7500. 1 .199 1.191 1.187 8000. 1.194 1.185 1.182 8500. 1.190 1.178 1.176 9000. 1.186 1.172 1.171 9500. 1.181 1.155 1.165 10000. 1.177 1.162 1.160 10500. 1.172 1.158 1.155 11000. 1.167 1.154 1.149 11500. 1.162 1.150 1.144 12000. 1.158 1.147 1.138 12500. 1.154 1.143 1.133 13000. 1 .150 1.139 1.128 13500. 1.146 1.135 1.122 14000. 1 .141 1.131 1.117 14500. 1.136 1.127 1.112 15000. 1.131 1.123 1.107 15500. 1.126 1.118 1.104 16000. 1.120 1.114 1.101 16500. 1.115 1.110 1.098 17000. 1.112 1.106 1.096 17500. 1.108 1.103 1.093 18000. 1 .105 1.099 1.091 18500. 1.103 1.097 1.090 19000. 1i.101 1.096 1.090 19500. 1 .089 1.095 1.089 20000. 1.097 1.094 1.099 20500. 1.095 1.092 1.089 21000. 1.094 1.092 1.089 21500. 1. 092 1.091 1.089 22000. 1.091 1.090 1.059 22500. 1.090 1.089 1.088 23000. 1.089 1.088 1.088 23500. 1.088 1.087 1.088 25000. 1.084 1.085 1.087 27500. 1.079 1.081 1.086 30000. 1 .079 1.078 1.085 32500. 1 .079 1.074 1.083 35000. 1.078 1.071 1.092 37500. 1.077 1.067 1.080 40000. 1 .075 1.067 1.079 42500. 1.072 1.066 1.078 45000. 1.069 1.064 1.077 47500. 1.068 1.062 1.076 50000. 1.068 1.060 1.075 52500. 1.065 1.057 1.074 55000. 1.061 1.054 1.073 57500. 1.055 1.051 1.073 60000. 2.047 1.050 2.072 62500. 1.038 1.050 1.072 65000. 1.039 1.051 1 .072 57500. 1.042 1.052 1 .072 70000. 1.058 1.053 1.072 AREVA Inc.
Controlled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page B-18 Table 8.17 [] Hot Uncontrolled k=
Exposure 0.00 Void 0.40 Void 0.80 Void MWd/MTUI History History History
- 0. 1.01633 0.99848 0.97433 100. 0.99451 0.97841 0.95676 500. 0.99264 0.97767 0.95730 1000. 0.99428 0.98032 0.96088 1500. 0.99715 0.98404 0.96523 2000. 1.00040 0.98809 0.98976 2500. 1.00372 0.99207 0.97420 3000. 1.00711 0.99608 0.97850 3500. 1.01063 1.00011 0.98272 4000. 1.01431 1.00422 0.98691 4500. 1.01816 1.00844 0.99111 9000. 1.02220 1.01278 0.899034 9500. 1.02645 1.01727 0.99961 6000. 1.03090 1.02192 1.00397 6500. 1.03556 1.02673 1.00841 7000. 1.04041 1.03170 1.01296 7600. 1.04545 1.03680 1.01761 8000. 1.05069 1.04203 1.02233 9500. 1.095604 1.04738 1.02714 9000. 1.06182 1.05287 1.03202 9500. 1.06742 1.05852 1.03698 10000. 1.07345 1.06434 1.04204 10500. 1.07971 1.07035 1.04720 11000. 1.08825 1.07667 1.05245 11500. 1.09308 1.08300 1.05782 12000. 1.10025 1.08967 1.06332 12500. 1.10783 1.09661 1.06893 13000. 1.11589 1.10387 1.07468 13500. 1.12448 1.11147 1.08058 14000. 1.13350 1.11935 1.08558 14500. 1.14280 1.12735 1.09265 15000. 1.15212 1.13531 1.09866 15500. 1.15103 1.14301 1.10453 16000. 1.16902 1.15013 1.11015 16500. 1.17563 1.15636 1.11539 17000. 1.18055 1.16141 1.12009 17500. 1.18362 1.15510 1.12411 18000. 1.18483 1.16741 1.12727 18500. 1.18431 1.16833 1.12953 19000. 1.18233 1.16795 1.13088 19500. 1.17925 1.15639 1.13135 20000. 1.17542 1.16387 1.13099 20500. 1.17061 1.16067 1.12988 21000. 1.16581 1.15697 1.12804 21500. 1.16100 1.15289 1.12565 22000. 1.15620 1.14841 1.12280 22500. 1.15138 1.14413 1.11962 23000. 1.14640 1.13969 1.11620 25000. 1.12642 1.12192 1.10114 27500. 1.10099 1.09961 1.08210 30000. 1.07511 1.07723 1.05321 32500. 1.04875 1.05476 1.04450 35000. 1.02195 1.03219 1.02612 37500. 0.99472 1.00956 1.00793 40000. 0.96717 0.98691 0.99001 42500. 0.93546 0.96430 0.97238 45000. 0.91177 0.94183 0.95511 47500. 0.88438 0.91962 0.93823 50000. 0.55754 0.89782 0.92181 52500. 0.83167 0.87659 0.90987 55000. 0.50709 0.85611 0.89049 57500. 0.78418 0.83655 0.87572 60000. 0.76323 0.81809 0.86160 62500. 0.74447 0.80089 0.84819 65000. 0.72801 0.78507 0.83553 67500. 0.71385 0.77070 0.82356 70000. 0.70189 0.75783 0.81260 AREVA Inc.
Controlled Docume nt Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page B-19 Table B.18[
J Hot Uncontrolled LPF Exposure 0.00 Void 0.40 Void 0.80 Void l4Wd/14TU History History History
- 0. 1.370 1.293 1.254 100. 1.372 1.294 1.251 500. 1.369 1.292 1.247 1000. 1.365 1.289 1.242 1500. 1.361 1.286 1.238 2000. 1.356 1.282 1.233 2500. 1.360 1.279 1.228 3000. 1.345 1.274 1.223 3500. 1.339 1.270 1.218 4000. 1.334 1.266 1.213 4500. 1 .328 1.262 1.208 5000. 1.322 1.257 1.203 5500. 1.316 1.253 1.198 6000. 1.310 1.248 1.192 6500. 1.303 1.244 1.187 7000. 1.297 1.239 1.182 7500. 1.291 1.234 1.177 9000. 1.284 1.230 1.171 8500. 1 .377 1.225 1.166 9000. 1.270 1.220 1.160 9500. 1.263 1.215 1.155 10000. 1.257 1.210 1.150 10800. 1.249 1.205 1.144 11000. 1.242 1.200 1.140 11500. 1.235 1.195 1.137 12000. 1.228 1.190 1.135 12500. 1.220 1.184 1.132 13000. 1.213 1.179 1.129 13500. 1.206 1.174 1.126 14000. 1 .198 1.168 1.124 14500. 1.191 1.163 1.121 15000. 1.183 1.158 1.119 15500. 1.176 1.154 1.116 16000. 1.169 1.149 1.114 16500. 1.163 1.145 1.113 17000. 1.157 1.141 i.iii 17500. 1.152 1.138 1.110 18000. 1.147 1.135 1.109 16500. 1.143 1.132 1.108 19000. 1.139 1.129 1.108 19500. 1.135 1.127 1.107 20000. 1.132 1.125 1.107 20500. 1.129 1.123 1.106 21000. 1.127 1.121 1.106 21500. 1 .124 1.119 1.105 22000. 1.122 1.118 1.105 22500. 1.119 1.116 1.104 23000. 1.117 1.115 1.104 25000. 1.107 1.109 1.102 27500. 1.102 1.101 1.099 30000. 1.098 1.094 1.096 32500. 1.093 1.087 1.094 35000. 1.088 1.083 1.091 37500. 1.083 1.081 1.089 40000. 1.077 1.079 1.087 42500. 1.075 1.075 1.085 45000. 1.074 1.071 1.083 47500. 1 .073 1.067 1.082 50000. 1 .071 1.063 1.090 52500. 1.087 1.059 1.079 55000. 1.061 1.055 1.079 57500. 1.054 1.052 1.077 60000. 1.045 1.050 1.077 62500. 1 .042 1.052 1.077 65000. 1.049 1.055 1.077 67500. 1 .056 1.058 1.077 70000. 1.063 1.062 1.078 AREVA Inc.
Controlled Document Nuclear FuelUnit Design Report ANP-3294NP Quad Cities 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page B-20 Table 6.19 [] Hot Uncontrolled ko Exposure 0.00 Void 0.40 Void 0.80 Void MWd/MTU History History History
- 0. 1.03070 1.01507 0.99362 100. 1.00885 0.99494 0.97595 500. 1.00807 0.99524 0.97746 1000. 1.01136 0. 99946 0. 98244 1500. 1.01607 1.00493 0. 98832 2000. 1.02117 1.01070 0. 98436 2500. 1.02643 1.01656 1.00031 3000. 1.03187 2.02247 1.00618 3500. 1.03755 1.02851 1.01201 4000. 1.04350 1.03471 1.01787 4500. 1.04574 1.04112 1.02379 5000. 1.05629 1.04775 1.02981 5500. 1.06315 1.05460 1.03595 6000. 1 .07029 1.06166 1.04221 6500. 1.07772 1.06893 1.04858 7000. 1.08547 1.07641 1.05508 7500. 1.09355 1.08413 1.06170 8000. 1.101599 1.09213 1.06848 8500. 1.11083 1.10041 1.07544 9000. 1.12005 1.10899 1.06256 9500. 1.12984 1.11791 1.08986 10000. 1.14010 1.12717 1.09733 10500. 1.15088 1.13678 1. 104894 11000. 1.16208 1.14662 1.11262 11500. 1.17343 1.15648 1.12027 12000. 1.18442 1. 16608 1.12775 12500. 1.19450 1.17505 1.13491 13000. 1.20311 1.18298 1.14153 13500. 1. 209585 1. 18952 1.14745 14000. 1.21450 1. 18446 1.15242 14500. 1.21705 1.19775 1.15632 15000. 1.21780 1.19946 1.15908 05500. 1. 21645 1.19963 1.16075 26000. 1.21358 1.19850 1.16137 16500. 1.21057 1.19628 1.16105 17000. 1.20656 1.19328 1.15987 17500. 1.20207 1.18973 1.15796 18000. 1. 19719 1.18580 1.15545 18500. 1. 19232 1.18140 1. 15249 19000. 1.18744 1.17700 1. 14919 19500. 1.18257 1.17260 1.14565 20000. 1.17769 1.16820 1.14196 22500. 1.15295 1.14584 1.12236 25000. 1.12781 1.12345 1.10287 27500. 1.10224 1.10101 1.08362 30000. 1.07621 1.07849 1. 064 61 32500. 1.04969 1.05586 1.04583 35000. 1.02271 1.03315 1.02728 37500. 0. 99531 1.01036 1.00897 40000. 0. 96760 0.98756 0.98093 42500. 0.93973 0.96482 0. 97319 45000. 0.91191 0.94222 0.95581 47500. 0.88441 0. 91991 0. 93884 50000. 0.85753 0.89802 0.92234 52500. 0.83164 0.87674 0.90635 55000. 0.80710 0.85623 0.89092 57500. 0.78427 0.83669 0.87612 60000. 0.76344 0.81827 0.86199 62500. 0.74484 0.80115 0.84858 65000. 0.72854 0.78542 0.83585 67500. 0.71457 0.77118 0.82412 70000. 0.70278 0.75844 0.81313 AREVA Inc.
Cuntrol-ed Documel~
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page B-21 Table B.20[ ] Hot Uncontrolled LPF Exposure 0.00 Void 0.40 Void 0.80 Void MWd/NTU History History History
- 0. 1.366 1.289 1.245 100. 1.368 1.291 1.242 500. 1.365 1.288 1.238 1000. 1.359 1.284 1.233 1500. 1.354 1.280 1.227 2000. 1.348 1.275 1.222 2500. 1.342 1.271 1.216 3000. 1.335 1.266 1.210 3500. 1.329 1.261 1.204 4000. 1.322 1.256 1.198 4500. 1.315 1.251 1.192 5000. 1.308 1.246 1.186 5500. 1.301 1.241 1.180 6000. 1.294 1.235 1.174 6500. 1.287 1.230 1.168 7000. 1.279 1.224 1.152 7500. 1.271 1.219 1.156 8000. 1.264 1.213 1.150 8600. 1.256 1.207 1.144 9000. 1.248 1.202 1.138 9500. 1.240 1.196 1.135 10000. 1.232 1.190 1.132 10500. 1.224 1.184 1.129 11000. 1.216 1.179 1.126 11500. 1.208 1.173 1.123 12000. 1.200 1.168 1.121 12600. 1.192 1.163 1.118 13000. 1.185 1.158 1.116 13600. 1.179 1.154 1.115 14000. 1.173 1.150 1.113 14600. 1.168 1.147 1.112 15000. 1.163 1.144 1.111 15500. 1.159 1.141 1.110 16000. 1.155 1.139 1.109 16600. 1.162 1.136 1.108 17000. 1.149 1.134 1.108 17500. 1.146 1.133 1.107 18000. 1.144 1.131 1.107 18500. 1.141 1.129 1.106 19000. 1.139 1.128 1.106 19500. 1.136 1.126 1.105 20000. 1.134 1.124 1.105 22500. 1.121 1.116 1.102 25000. 1.108 1.108 1.100 27500. 1.100 1.101 1.097 30000. 1.096 1.093 1.094 32500. 1.091 1.086 1.092 35000. 1.086 1.080 1.089 37500. 1.080 1.078 1.087 40000. 1.074 1.075 1.085 42500. 1.071 1.072 1.083 45000. 1.069 1.068 1.081 47500. 1.068 1.064 1.079 50000. 1.066 1.060 1.078 52500. 1.062 1.056 1.077 55000. 1.056 1.053 1.076 57500. 1.048 1.051 1.075 60000. 1.039 1.049 1.075 62600. 1.040 1.050 1.074 66000. 1.047 1.053 1.075 67500. 1.055 1.056 1.075 70000. 1.061 1.060 1.076 AREVA Inc.
Controfled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page B-22 Table B.21[
] Hot Uncontrolled k=
Exposure 0.00 Void 0.40 Void 0.80 Void l4Wd/?4TU History History History
- 0. 1.10092 1.07923 1.05218 100. 1.07733 1.05753 1.03312 500. 1.07412 1.05522 1.03184 1000. 1.07401 1.05579 1.03300 1500. 1.07493 1.05720 1.03476 2000. 1.07612 1.08881 1.03659 2500. 1.07737 1.06040 1.03833 3000. 1.07857 1.06189 1.03992 3500. 1.07976 1.06331 1.04139 4000. 1.08098 1.06470 1.04277 4500. 1.08226 1.06610 1.04411 5000. 1.08362 1.06754 1.04542 5500. 1.08509 1.06904 1.04675 8000. 1.08669 1.07063 1.04811 6500. 1.08842 1.07232 1.04952 7000. 1.09029 1.07411 1.05100 7500. 1.09228 1.07599 1.05255 8000. 1.09437 1.07795 1.05418 8800. 1.09658 1.07998 1.05585 -
9000. 1.08883 1.08207 1.05758 9500. 1.10121 1.08425 1.05934 10000. 1.10370 1.08650 1.06115 10500. 1.10833 1.08885 1.06300 11000. 1.10910 1.09129 1.06489 11500. 1.11200 1.09383 1.06682 12000. 1.11504 1.09648 1.06880 12500. 1.11823 1.09922 1.07083 13000. 1.12158 1.10207 1.07291 13500. 1.12512 1.10503 1.07504 14000. 1.12888 1.10812 1.07724 14500. 1.13294 1.11136 1.07949 15000. 1.13727 1.11478 1.08182 15500. 1.14188 1.11837 1.08421 15000. 2.14669 1.12210 1.08668 18500. 1.15159 1.12592 1.08920 17000. 1.15839 1.12989 1.09172 17500. 1.16080 1.13331 1.09422 18000. 1.16455 1.13658 1.09658 18500. 1.16740 1.13935 1.09875 19000. 1.16918 1.14146 1.10065 19500. 1.16982 1.14280 1.10218 20000. 1.16929 1.14332 1.10328 20500. 1.16787 1.14303 1.10389 21000. 1.16511 1.14193 1.10397 21500. 1.16185 1.14010 1.10353 22000. 1.15809 1.13765 1.10260 22500. 1.15392 1.13470 1.10120 23000. 1.14942 1.13138 1.09938 23500. 1.14492 1.12779 1.09719 24000. 1.14041 1.12402 1.09468 24500. 1.13591 1.12001 1.09191 25000. 1.13141 1.11601 1.08893 25500. 1.12685 1.11186 1.08579 26000. 1.12228 1.10791 1.08253 26500. 1.11772 1.10387 1.07919 27000. 1.11315 1.09982 1.07579 27500. 1.10859 1.08577 1.07232 30000. 1.08567 1.07568 1.05496 32500. 1.06266 1.05576 1.03790 35000. 1.03956 1.03602 1.02119 37500. 1.01640 1.01647 1.00486 40000. 0.99324 0.99714 0.98893 42500. 0.97014 0.97806 0.97340 45000. 0.94719 0.95928 0.95831 47500. 0.92451 0.94086 0.94368 50000. 0.90224 0.92286 0.92954 52500. 0.88054 0.90835 0.91590 55000. 0.85959 0.88840 0.90280 87800. 0.83956 0.87209 0.89025 60000. 0.82062 0.85650 0.87826 62500. 0.80292 0.84170 0.86688 65000. 0.78660 0.82776 0.85604 67800. 0.77174 0.81471 0.84583 70000. 0.75840 0.80259 0.83622 AREVA Inc.
ControIled Document Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page B-23 Table B.22[
] Hot Uncontrolled LPF Exposure 0.00 Void 0.40 Void 0.80 Void HWd/MTU History History History
- 0. 1.306 1.281 1.272 100. 1.302 1.280 1.271 500. 1.297 1.277 1.268 1000. 1.292 1.274 1.265 1500. 1.287 1.270 1.263 2000. 1.281 1.266 1.259 2500. 1.275 1.262 1.255 3000. 1.268 1.259 1.252 3500. 1.262 1.255 1.248 4000. 1.256 1.251 1.245 4500. 1.249 1.247 1.242 5000. 1.245 1.243 1.239 5500. 1.241 1.239 1.235 5000. 1.237 1.235 1.232 6500. 1.232 1.231 1.229 7000. 1.228 1.227 1.225 7500. 1.223 1.223 1.222 8000. 1.215 1.219 1.218 5500. 1.214 1.215 1.215 9000. 1.210 1.211 1.212 9500. 1.205 1.207 1.208 10000. 1.200 1.203 1.204 10500. 1.196 1.198 1.201 11000. 1.191 1.194 1.197 11505. 1.186 1.190 1.194 12000. 1.181 1.186 1.190 12500. 1.176 1.181 1.187 13000. 1.171 1.177 1.183 13500. 1.168 1.173 1.180 14000. 1.161 1.168 1.176 14500. 1.155 1.164 1.172 15000. 1.150 1.159 1.169 15500. 1.145 1.155 1.165 16000. 1.139 1.150 1.152 16500. 1.133 1.146 1.158 17000. 1.128 1.141 1.155 17500. 1.123 1.136 1.151 15000. 1.118 1.132 1.147 18500. 1.114 1.128 1.144 19000. 1.110 1.124 1.140 15500. 1.107 1.120 1.136 20000. 1.103 1.117 1.133 20500. 1.101 1.114 1.130 21000. 1.098 1.111 1.128 21500. 1.096 1.109 1.125 22000. 1.094 1.107 1.123 22500. 1.092 1.105 1.121 23000. 1.090 1.103 1.119 23500. 1.089 1.101 1.117 24000. 1.087 1.099 1.115 24500. 1.086 1.097 1.114 25000. 1.084 1.096 1.112 25500. 1.083 1.094 i.iii 26000. 1.082 1.093 1.109 26500. 1.081 1.091 1.108 27000. 1 .080 1.090 1.107 27500. 1.079 1.088 1.106 30000. 1.076 1.081 1.100 32500. 1.072 1.073 1.094 35000. 1 .068 1.071 1.089 37500. 1 .064 1.068 1.083 40000. 1 .061 1.085 1.078 42500. 1.057 1.062 1.074 45000. 1.053 1.058 1.069 47500. 1.049 1.056 1.085 50000. 1.049 1.054 1.064 52500. 1.050 1.051 1.072 55000. 1.049 1.049 1.084 57500. 1.046 1.047 1.097 60000. 1.042 1.044 1.110 62500. 1.036 1.053 1.122 65000. 1.053 1.071 1.135 67500. 1.075 1.088 1.148 70000. 1.094 1.104 1.160 AREVA Inc.
onroflei Docurnen't Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 1OXM Fuel Page 6-24 Table B.23[
J Hot Uncontrolled k*
Exposure 0.00 Void 0.40 Void 0.80 Void MWd/MTU History History History
- 0. 1.04319 1.02535 1.00194 100. 1.02026 1.00412 0.98313 500. 1.01776 1.00259 0.96271 1000. 1.01860 1.00425 0.98512 1500. 1.02057 1.00687 0.98824 2000. 1.02288 1.00973 0.98150 2500. 1.02523 1.01260 0.99468 3000. 1.02758 1.01538 0.99770 3500. 1.03000 1.01815 1.00062 4000. 1.03251 1.02096 1.00349 4500. 1.03515 1.02383 1.00635 5000. 1.03795 1.02680 1.00923 5500. 1.04093 1.02990 1.01216 6000. 1.04409 1.03314 1.01517 6500. 1.04745 1.03653 1.01827 7000. 1.05096 1.04005 1.02146 7500. 1.05462 1.04368 1.02473 8000. 1.05840 1.04740 1.02809 8500. 1.06231 1.05121 1.03150 9000. 1.06638 1.05511 1.03496 9500. 1.07057 1.05913 1.03849 10000. 1.07496 1.06327 1.04208 10500. 1.07953 1.06756 1.04575 11000. 1.06427 1.07198 1.04949 11500. 1.08921 1.07655 1.05330 12000. 1.09439 1.08127 1.05719 12500. 1.09963 1.08615 1.06116 13000. 1.10556 1.09124 1.06522 13500. 1.11171 1.09657 1.06939 14000. 1.11621 1.10217 1.07367 14500. 1.12511 1.10806 1.07811 15000. 1.13228 1.11418 1.08269 15500. 1.13957 1.12045 1.08740 16000. 1.14668 1.12665 1.09217 16500. 1.15319 1.13257 1.09686 17000. 1.15675 1.13788 1.10135 17500. 1.16306 1.14236 1.10540 16000. 1.15589 1.14578 1.10900 16500. 1.16716 1.14800 1.11186 19000. 1.16690 1.14897 1.11393 19500. 1.16528 1.14872 1.11514 20000. 1.16256 1.14738 1.11551 20500. 1.15906 1.14512 1.11507 21000. 1.15503 1.14217 1.11388 21500. 1.15037 1.13871 1.11204 22000. 1.14570 1.13492 1.10965 22500. 1.14104 1.13082 1.10684 23000. 1.13620 1.12651 1.10371 23500. 1.13136 1.12221 1.10035 25000. 1.11685 1.10929 1.08936 27500. 1.09241 1.08772 1.07071 30000. 1.06766 1.06615 1.05218 32500. 1.04261 1.04457 1.03390 35000. 1.01722 1.02300 1.01589 37500. 0.99156 1.00146 0.99815 40000. 0.96571 0.91997 0.98070 42500. 0.93978 0.95861 0.96359 45000. 0.91393 0.93745 0.94684 47500. 0.88837 0.91659 0.93050 50000. 0.86333 0.89614 0.91463 52500. 0.83909 0.87624 0.89925 55000. 0.81593 0.85702 0.88443 57500. 0.79413 0.83862 0.87021 60000. 0.77395 0.82118 0.85662 62500. 0.75559 0.80482 0.84372 65000. 0.73917 0.78965 0.83153 67500. 0.72476 0.77973 0.82008 70000. 0.71230 0.76311 0.80940 AREVA Inc.
Controiled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision i Representative Cycle ATRIUM 1OXM Fuel Page 8-25 Table B.24 [ ] Hot Uncontrolled LPF Exposure 0.00 Void 0.40 Void 0.80 Void 145d/MTU History History History
- 0. 1.310 1.296 1.280 100. 1.305 1.2899 1.280 500. 1.301 1.285 1.278 1000. 1.296 1.281 1 .275 1500. 1.290 1.277 1.272 2000. 1.284 1.273 1.268 2500. 1.277 1.268 1.264 3000. 1.270 1.264 1.261 3500. 1.265 1.259 1.267 4000. 1.259 1.255 1.253 4500. 1.254 1.250 1.249 5000. 1.248 1.246 1.245 5500. 1.242 1.241 1.241 6000. 1.238 1.236 1.236 6500. 1.231 1.230 1.232 7000. 1.225 1.225 1.227 7500. 1.219 1.220 1.222 8000. 1.213 1.214 1.218 8500. 1.207 1.209 1.213 9000. 1.201 1.204 1 .208 9500. 1.195 1.198 1.203 10000. 1.189 1.193 1 .198 10500. 1.182 1.187 1 .194 11000. 1.176 1.181 1.189 11500. 1.170 1.176 1.184 12000. 1.163 1.170 1.179 12500. 1.158 1.164 1.174 13000. 1.155 1.158 1.169 13500. 1.151 1.152 1.164 14000. 1.147 1.146 1.159 14500. 1.143 1.140 1.154 15000. 1.139 1.134 1.149 15500. 1.134 1.128 1.144 16000. 1.129 1.122 1.139 16500. 1.124 1.117 1.134 17000. 1.119 1.111 1 .129 17500. 1.114 1.106 1.125 18000. 1.110 1.103 1.120 18500. 1.106 1.100 1.116 19000. 1.102 1.098 1 .112 18800. 1.099 1.095 1.109 20000. 1.097 1.093 1.106 20500. 1.094 1.092 1.103 21000. 1.093 1.090 1.100 21500. 1.092 1.089 1.098 22000. 1.090 1.088 1.096 22500. 1.089 1.087 1.094 23000. 1.088 1.086 1.092 23500. 1.086 1.085 1.090 25000. 1.082 1.083 1.086 27500. 1.076 1.079 1.083 30000. 1.070 1.078 1.082 32500. 1.068 1.072 1.080 35000. 1.067 1.069 1.079 37500. 1.065 1.065 1.078 40000. 1.067 1.0 62 1.077 42500. 1.067 1.059 1.075 45000. 1.069 1.058 1.075 47500. 1.071 1.057 1 .074 50000. 1.071 1.057 1 .073 52500. 1.069 1.055 1 .072 55000. 1.065 1.054 1.071 57500. 1.058 1.052 1 .071 50000. 1.050 1.050 1 .070 52500. 1.041 1.049 1.070 85000. 1.037 1.049 1 .070 87500. 1 .041 1.050 1 .070 70000. 1.056 1.051 1.071 AREVA Inc.
ControWea Document Nuclear Fuel Design Report ANP-g294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page B-26 Table B.25 [] Hot Uncontrolled k*
Exposure 0.00 Void 0.40 Void 0.80 Void MWd/14TU History History History
- 0. 1.05435 1.03105 1.01170 100. 1.03084 1.01528 0.99251 000. 1.02809 1.01355 0.99200 1000. 1.02974 1.01508 0.99439 1500. 1.03059 1.01765 0.99754 2000. 1.03279 1.02051 1.00086 2500. 1.03507 1.02337 1.00410 3000. 1.03736 1.02618 1.00721 3000. 1.03974 1.02899 1.01022 4000. 1.04224 1.03186 1.01319 4000. 1.04490 1.03482 1.01818 5000. 1.04773 1.03790 1.01917 5500. 1.05076 1.04112 1.02224 6000. 1.05399 1.04451 1.02540 5500. 1.05743 1.04805 1.02865 7000. 1.05104 1.05175 1.03200 7500. 1.05480 1.09556 1.03545 8000. 1.05970 1.05948 1.03897 8500. 1.07275 1.06349 1.04256 9000. 1.07699 1.06762 1.04521 9500. 1.08133 1.07187 1.04884 10000. 1.08591 1.07627 1.05374 10500. 1.09068 1.08082 1.05761 11000. 1.09965 1.08553 1.06159 11500. 1.10085 1.09040 1.06962 12000. 1.10632 1.09544 1.06975 12500. 1.11209 1.10068 1.07387 13000. 1.11822 1.10617 1.07828 13500. 1.12475 1.11194 1.08272 14000. 1.13170 1.11802 1.08730 14500. 1.13904 1.12438 1.09205 15000. 1.14660 1.13102 1.08687 15500. 1.15423 1.13777 1.10202 16000. 1.16165 1.14439 1.10712 16500. 1.16833 1.15058 1.11213 17000. 1.17389 1.15606 1.11685 17500. 1.17808 1.18057 1.12110 18000. 1.18072 1.18389 1.12473 18500. 1.18171 1.16581 1.12758 19000. 1.18109 1.16643 1.129566 19500. 1.17908 1.16577 1.13062 20000. 1.17600 1.18399 1.13077 20500. 1.17216 1.18132 1.13009 21000. 1.16739 1.15800 1.12863 21500. 1.16282 1.15423 1.12652 22000. 1.15785 1.14999 1.12388 22500. 1.15308 1.14574 1.12086 23000. 1.14808 1.14129 1.11754 23500. 1.14307 1.13684 1.11402 25000. 1.12806 1.12348 1.10266 27800. 1.10259 1.10114 1.08355 30000. 1.07668 1.07871 1.06461 32500. 1.05029 1.05620 1.04589 35000. 1.02344 1.03358 1.02741 37500. 0.99617 1.01091 1.00917 40000. 0.98859 0.98820 0.99120 42500. 0.94083 0.96555 0.97353 45000. 0.91310 0.94304 0.95621 47500. 0.88565 0.92078 0.93928 50000. 0.85879 0.89894 0.92281 52500. 0.83286 0.87765 0.90583 55000. 0.80824 0.85714 0.89141 57500. 0.78527" 0.83754 0.87560 50000. 0.76426 0.81904 0.86245 62500. 0.74544 0.80180 0.84901 85000. 0.72892 0.78594 0.83632 67500. 0.71471 0.77154 0.82443 70000. 0.70270 0.75864 0.81335 AREVA Inc.
Contro~ledI Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page B-27 Table B.26 [ ] Hot Uncontrolled LPF Exposure 0.00 Void 0.40 Void 0.80 Void MWd/M4TU History History History
- 0. 1.346 1.296 1.271 100. 1.349 1.289 1.271 000. 1.347 1.284 1.269 1000. 1.343 1.278 1.266 1500. 1.340 1.273 1.263 2000. 1.336 1.287 1.259 2500. 1.332 1.263 1.256 3000. 1.328 1.260 1.252 3500. 1.323 1.257 1.248 4000. 1.319 1.254 1.244 4000. 1.314 1.251 1.240 5000. 1.310 1.247 1.238 5500. 1.305 1.244 1.232 6000. 1.300 1.240 1.228 6500. 1.295 1.237 1.223 7000. 1.290 1.233 1.219 7500. 1.295 1.229 1.214 8000. 1.279 1.226 1.209 8500. 1.274 1.222 1.205 9000. 1.268 1.218 1.200 9500. 1.262 1.214 1.195 10000. 1.256 1.210 1.190 10500. 1.251 1.206 1.185 11000. 1.245 1.202 1.180 11500. 1.239 1.198 1.175 12000. 1.233 1.193 1.170 12500. 1.227 1.189 1.165 13000. 1.221 1.185 1.160 13500. 1.215 1.181 1.156 14000. 1.209 1.176 1.151 14500. 1.202 1.172 1.146 15000. 1.198 1.168 1.141 15500. 1.188 1.163 1.136 16000. 1.181 1.158 1.131 16500. 1.173 1.153 1.126 17000. 1.166 1.148 1.121 17500. 1.159 1.144 1.117 18000. 1.152 1.139 1.112 19500. 1.146 1.135 1.110 19000. 1.141 1.131 1.109 19500. 1.136 1.128 1.107 20000. 1.132 1.125 1.106 20500. 1.129 1.123 1.105 21000. 1.126 1.120 1.104 21500. 1.123 1.118 1.103 22000. 1.121 1.117 1.102 22500. 1.118 1.115 1.102 23000. 1.116 1.113 1.101 23500. 1.113 1.112 1.101 25000. 1.106 1.107 1.099 27500. 1.093 1.099 1.097 30000. 1.085 1.092 1.094 32500. 1.080 1.085 1.091 35000. 1.075 1.078 1.089 37500. 1.072 1.072 1.087 40000. 1.072 1.066 1.085 42500. 1.075 1.063 1.083 45000. 1.077 1.062 1.081 47500. 1.077 1.061 1.080 50000. 1.075 1.059 1.078 82500. 1.071 1.057 1.077 55000. 1.065 1.055 1.076 57500. 1.058 1.053 1.075 60000. 1.048 1.051 1.075 62500. 1.040 1.050 1.075 85000. 1.047 1.053 1.075 67500. 1.058 1.057 1.076 70000. 1.082 1.061 1.076 AREVA Inc.
Control~ed Document Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page B-28 Table B.27 [ J Hot Uncontrolled k.
Exposure 0.00 Void 0.40 Void 0.80 Void M4Wd/MTU History History History
- 0. 1.06781 1.05261 1.02986 100. 1.04424 1.03075 1.01055 500. 1 .04242 1.02990 1.01085 1000. 1 .04450 1.03278 1.01442 1500. 1 .04753 1.03685 1.01887 2000. 1.05174 1.04121 1 .02348 2500. 1 .05565 1.04561 1 .02800 3000. 1.05970 1.05005 1.03242 3500. 1 .06388 1.05458 1.03681 4000. 1.06844 1.05927 1.04120 4500. 1.07321 1.06414 1.04567 5000. 1 .07827 1.06924 1.05025 5500. 1.08358 1.07453 1.05493 8000. 1 .08815 1.08000 1.05972 6500. 1.09494 1.08562 1. 064 60 7000. 1.10059 1.09141 1.06859 7500. 1.10732 1.09741 1. 074 68 8000. 1.11396 1.10363 1.07989 8500. 1.12090 1.11008 1.08525 9000. 1.12818 1.11677 1.09074 9500. 1.13582 1.12371 1.09639 10000. 1.14389 1.13093 1.10218 10500. 1.15240 1.13847 1.10811 11000. 1. 15134 1.14634 1. 114 20 11500. 1.17060 1. 15446 1.12041 12000. 1.17996 1. 16270 1.12673 12500. 1.18902 1.17078 1.13304 13000. 1.19729 1.17830 1.13917 13500. 1.20428 1.18495 1.14486 14000. 1.20967 1. 19040 1.14989 14500. 1 .21331 1.19447 1.15408 15000. 1.21512 1.19706 1.15729 15500. 1.21518 1.19817 1. 15949 16000. 1.21370 1.19787 1. 160 65 16500. 1.21102 1.19635 1. 16082 17000. 1 .20750 1.19387 1. 16007 17500. 1.20342 1.19068 1.15851 18000. 1.19880 1.18700 1.15627 18500. 1.19378 1.18300 1 .15351 19000. 1.18897 1.17850 1 .15036 15500. 1 .18415 1.17419 1 .14692 20000. 1 .17933 1. 15979 1.14329 22500. 1 .15459 1.14736 1.12379 25000. 1 .12942 1.12494 1.10427 27500. 1 .10382 1. 10246 1. 084 97 30000. 1.07776 1.07990 1. 065 91 32500. 1 .05122 1.05724 1.04709 35000. 1.02420 1. 03449 1.02849 37500. 0.99677 1.01167 1.01014 40000. 0. 96902 0.98883 0.99205 42500. 0. 94111 0.98604 0.97428 45000. 0.91324 0.94340 0.95685 47500. 0.88569 0.92104 0.93985 50000. 0.85876 0.89911 0.92330 52500. 0.83281 0.87778 0.90727 55000. 0.80820 0.85723 0. 89180 57500. 0.78530 0.9837683 0.87696 60000. 0.78440 0. 81917 0.8 6280 62500. 0.74572 0.80200 0.84 936 65000. 0.72936 0. 786823 0.83670 67500. 0.71532 0. 77194 0.82484 70000. 0.70347 0.75917 0.81381 AREVA Inc.
Controiied Docment Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page B-29 Table B.28[
] Hot Uncontrolled LPF Exposure 0.00 Void 0.40 Void 0.80 Void llWd/MTUJ History History History
- 0. 1.343 1.288 1.266 100. 1.345 1.261 1.265 500. 1.342 1.275 1.263 1000. 1.339 1.268 1.259 1500. 1.334 1.264 1.256 2000. 1 .330 1.261 1.251 2500. 1 .325 1.257 1.247 3000. 1.320 1.254 1.243 3500. 1.315 1.250 1.235 4000. 1.310 1.246 1.233 4500. 1.305 1.242 1.229 5000. 1.299 1.238 1.224 5500. 1.293 1.234 1.219 6000. 1.288 1.230 1.214 5500. 1.282 1.226 1.208 7000. 1.276 1.222 1.203 7500. 1.270 1.217 1.198 8000. 1.263 1.213 1.193 8500. 1.257 1.208 1.167 9000. 1.251 1.204 1.162 5500. 1.244 1.199 1.176 10000. 1.238 1.194 1.171 10500. 1 .231 1.190 1.165 11000. 1.224 1.185 1.160 11500. 1 .217 1.180 1.154 12000. 1.210 1.175 1.148 12500. 1.202 1.170 1.143 13000. 1.194 1.165 1.138 13500. 1.187 1.160 1.133 14000. 1 .179 1.155 1.128 14500. 1 .172 1.151 1.123 15000. 1.166 1.146 1.119 15500. 1 .161 1.143 1.115 18000. 1.156 1.139 1.112 16800. 1 .152 1.136 1.109 17000. 1 .149 1.134 1.107 17500. 1.146 1.132 1.106 18000. 1.143 1.130 1.105 18500. 1.141 1.128 1.104 18000. 1.138 1.126 1.104 19500. 1.136 1.125 1.103 20000. 1.133 1.123 1.103 22500. 1.120 1.115 1.1I00 25000. 1 .107 1.107 1.097 27500. 1.095 1.099 1.095 30000. 1.086 1.092 1.092 32500. 1.081 1.084 1.090 35000. 1.075 1.078 1.087 37500. 1.070 1.071 1.085 40000. 1.069 1.066 1.083 42500. 1.069 1.063 1.081 45000. 1.071 1.062 1.079 47500. 1.071 1.060 1.078 50000. 1.0 69 1.058 1.076 52500. 1.0 65 1.056 1.075 55000. 1.059 1.054 1.074 57500. 1.052 1.052 1.073 60000. 1.043 1.050 1.073 62500. 1.039 1.049 1.073 65000. 1.046 1.052 1.073 67500. 1.053 1.055 1.074 70000. 1.060 1.059 1.074 AREVA Inc.
Cont,'oIIed Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM I0XM Fuel Page C-I Appendix C Enriched Lattice Isotopic Data Tables The results in this appendix are based on hot operating and equilibrium xenon conditions.
AREVA Inc.
Controlled Documen Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page C-2 Table C.1 [ ] Exposure-Dependent 0% Void Isotopics (kgIMTU Initial)
Exposure kdWd/MTU U-234 0-235 U-235 U-238 NP-237 PU-238 PU-239 P0-240 PU-241 P0-242 0.0 0.358 44.780 0.000 954.862 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.358 44.659 0.023 954.809 0.000 0.000 0.021 0.000 0.000 0.000 500.0 0.356 44.182 0.113 954.595 0.002 0.000 0.157 0.002 0.000 0.000 1000.0 0.354 43.593 0.2205954.328 0.004 0.000 0.419 0.007 0.000 0.000 1500.0 0.352 43.013 0.334 554.060 0.006 0.000 0.629 0.015 0.001 0.000 2000.0 0.350 42.441 0.442 953.793 0.009 0.000 0.830 0.026 0.002 0.000 2500.0 0.348 41.876 0.548 953.527 0.011 0.000 1.021 0.040 0.005 0.000 3000.0 0.346 41.319 0.652 953.261 0.013 0.000 1.203 0.056 0.008 0.000 3500.0 0.344 40.768 0.755 952.995 0.018 0.001 1.377 0.074 0.011 0.000 4000.0 0.342 40.224 0.856 952.730 0.020 0.001 1.542 0.093 0.016 0.000 4500.0 0.340 39.686 0.958 952.465 0.023 0.001 1.699 0.114 0.022 0.001 5000.0 0.338 39.155 1.054 952.200 0.026 0.001 1.848 0.137 0.028 0.001 5500.0 0.336 38.828 1.151 951.936 0.030 0.001 1.991 0.160 0.036 0.001 6000.0 0.335 38.108 1.248 951.873 0.034 0.002 2.127 0.184 0.045 0.002 6500.0 0.333 37.594 1.340 951.410 0.038 0.002 2.256 0.210 0.054 0.002 7000.0 0.231 37.084 1.433 951.148 0.042 0.002 2.379 0.236 0.064 0.003 7500.0 0.329 36.579 1.525 950.886 0.046 0.003 2.496 0.263 0.075 0.004 8000.0 0.327 36.080 1.615 950.625 0.050 0.003 2.607 0.290 0.087 0.005 8500.0 0.325 25.585 1.704 950.364 0.054 0.004 2.712 0.318 0.099 0.006 9000.0 0.323 25.095 1.792 950.103 0.059 0.004 2.813 0.347 0.111 0.007 0500.0 0.322 34.609 1.879 949.843 0.063 0.005 2.908 0.376 0.125 0.008 10000.0 0.320 34.127 1.965 949.594 0.068 0.006 2.898 0.405 0.138 0.010 10500.0 0.318 33.650 2.050 949.324 0.073 0.006 3.084 0.435 0.152 0.012 11000.0 0.316 33.177 2.134 949.066 0.077 0.007 3.165 0.465 0.187 0.014 11500.0 0.314 32.708 2.216 948.808 0.082 0.008 3.242 0.495 0.182 0.016 12000.0 0.313 32.243 2.298 948.550 0.087 0.008 3.314 0.526 0.197 0.018 12500.0 0.311 31.781 2.378 948.293 0.092 0.009 3.383 0.557 0.213 0.020 13000.0 0.309 31.323 2.458 948.036 0.098 0.010 3.448 0.588 0.228 0.023 13500.0 0.307 30.869 2.537 947.779 0.103 0.011 3.509 0.619 0.244 0.025 14000.0 0.306 30.418 2.615 947.523 0.108 0.012 3.566 0.651 0.260 0.028 14500.0 0.304 29.971 2.691 947.287 0.113 0.013 3.620 0.682 0.276 0.031 15000.0 0.302 29.527 2.767 947.012 0.119 0.014 3.671 0.714 0.292 0.034 15500.0 0.301 29.087 2.843 -946.756 0.124 0.015 3.720 0.745 0.308 0.038 16000.0 0.299 28.649 2.917 946.500 0.130 0.016 3.765 0.777 0.325 0.041 16500.0 0.297 28.216 2.990 946.243 0.135 0.018 3.808 0.809 0.341 0.045 17000.0 0.296 27.785 3.063 945.986 0.141 0.019 3.849 0.840 0.358 0.049 17500.0 0.294 27.358 3.135 945.728 0.147 0.020 3.887 0.872 0.374 0.053 18000.0 0.292 26.935 3.208 945.469 0.153 0.022 3.924 0.903 0.391 0.058 18500.0 0.291 26.514 3.276 945.209 0.158 0.023 3.959 0.935 0.408 0.062 19000.0 0.289 26.098 3.345 944.948 0.164 0.025 3.991 0.966 0.424 0.067 19500.0 0.287 25.684 3.414 944.685 0.170 0.026 4.022 0.898 0.441 0.072 20000.0 0.288 25.274 3.481 944.422 0.176 0.028 4.052 1.029 0.458 0.077 22500.0 0.277 22.276 3.808 943.083 0.207 0.037 4.176 1.183 0.543 0.106 25000.0 0.269 21.363 4.115 941.709 0.240 0.048 4.266 1.334 0.626 0.140 27500.0 0.261 19.536 4.402 940.299 0.274 0.080 4.326 1.480 0.705 0.180 30000.0 0.253 17.793 4.669 938.849 0.308 0.075 4.359 1.622 0.780 0.226 32500.0 0.244 16.135 4.917 937.358 0.344 0.091 4.371 1.757 0.849 0.277 35000.0 0.236 14.563 5.146 935.823 0.380 0.110 4.364 1.866 0.913 0.333 37500.0 0.228 13.077 5.355 934.242 0.416 0.130 4.341 2.009 0.968 0.395 40000.0 0.220 11.679 5.544 932.612 0.452 0.151 4.306 2.123 1.020 0.462 42500.0 0.212 10.369 5.714 930.931 0.487 0.175 4.260 2.229 1.064 0.534 45000.0 0.204 9.147 5.865 929.195 0.522 0.199 4.206 2.327 1.101 0.611 47500.0 0.156 8.016 5.995 927.403 0.556 0.225 4.146 2.416 1.132 0.693 50000.0 0.188 6.976 6.107 925.553 0.589 0.251 4.083 2.496 1.156 0.778 52500.0 0.180 6.026 6.199 923.642 0.621 0.278 4.018 2.568 1.176 0.868 55000.0 0.173 5.165 6.272 921.870 0.651 0.308 3.952 2.630 1.190 0.960 57500.0 0.155 4.394 6.326 818.636 0.680 0.332 3.888 2.683 1.199 1.056 60000.0 0.158 3.708 6.363 917.540 0.706 0.358 3.827 2.728 1.205 1.153 62500.0 0.151 3.106 6.382 915.385 0.730 0.384 3.769 2.765 1.207 1.253 65000.0 0.144 2.582 6.386 913.171 0.752 0.408 3.715 2.795 1.207 1.354 67500.0 0.137 2.131 6.375 910.903 0.772 0.430 3.665 2.818 1.204 1.455 70000.0 0.130 1.748 6.351 909.584 0.789 0.451 3.620 2.835 1.200 1.556 AREVA Inc.
Controlled Docunent Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page C-3 Table C.2 [ ] Exposure-Dependent 40% Void Isotopics (kg/MTU Initial)
Exposure M4Wd/MTU1 U-224 U1-235 U1-236 U1-238 NP-237 PU1-238 PU1-239 PU1-240 PU1-241 PU1-242 0.0 0.358 44.780 0.000 854.862 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.358 44.660 0.024 854.802 0.000 0.000 0.024 0.000 0,000 0.000 500.0 0.358 44.184 0.118 954.559 0.002 0.000 0.222 0.002 0.000 0.000 1000.0 0.354 43,599 0.233 954.255 0.004 0.000 0.472 0.008 0.000 0.000 1500.0 0.351 43.023 0.348 953.982 0.007 0.000 0.710 0.017 0.001 0.000 2000.0 0.348 42.458 0.458 953.649 0.010 0.000 0.936 0.030 0.003 0.000 2500.0 0.347 41.897 0.567 953.347 0.013 0.000 1.152 0.045 0.008 0.000 3000.0 0.345 41.348 0.674 953.045 0.016 0.000 1.357 0.082 0.010 0.000 3500.0 0.342 40.803 0.780 952.744 0.019 0.001 1.553 0.082 0.015 0.000 4000.0 0.340 40.287 0.884 952.444 0.023 0.001 1.739 0.103 0.021 0.001 4500.0 0.238 39.738 0.986 952.144 0.027 0.001 1.917 0.125 0.028 0.001 5000.0 0.338 39.216 1.086 951.844 0.031 0.001 2.086 0.149 0.036 0.001 5500.0 0.334 38.700 1.185 951.548 0.035 0.002 2.248 0.174 0.046 0.002 6000.0 0.332 38.191 1.283 951.248 0.040 0.002 2.402 0.200 0.056 0.002 6500.0 0.330 37.687 1.378 950.950 0.044 0.003 2.549 0.227 0.067 0.003 7000.0 0.328 37.189 1.473 950.653 0.049 0.003 2.689 0.255 0.079 0.004 7500.0 0.328 36.696 1.566 950.357 0.054 0.004 2.822 0.284 0.092 0.005 8000.0 0.323 26.209 1.658 950.052 0.059 0.004 2.949 0.313 0.106 0.006 8500.0 0.321 35.727 1.748 949.766 0.064 0.005 3.070 0.343 0.121 0.007 9000.0 0.319 35.250 1.837 949.472 0.070 0.006 3.186 0.373 0.136 0.009 9500.0 0.317 34.777 1.924 949.178 0.075 0.006 3.296 0.403 0.151 0.010 10000.0 0.315 34.310 2.011 948.885 0.081 0.007 3.400 0.435 0.168 0.012 10500.0 0.314 33.847 2.096 948.892 0.086 0.008 3.500 0.466 0.184 0.014 11000.0 0.312 33.388 2.180 948.300 0.092 0.009 3.594 0.498 0.201 0.016 11500.0 0.310 32.834 2.263 948.008 0.098 0.010 3.684 0.530 0.219 0.018 12000.0 0.308 32.484 2.345 947.717 0.104 0.011 3.769 0.562 0.236 0.021 12500.0 0.306 32.039 2.426 947.426 0.110 0.012 3.850 0.595 0.254 0.023 13000.0 0.304 31.597 2.505 947.136 0.116 0.013 3.927 0.628 0.273 0.028 13500.0 0.302 31.159 2.584 946.846 0.122 0.014 4.000 0.661 0.291 0.029 14000.0 0.300 20.724 2.661 946.557 0.128 0.015 4.069 0.694 0.310 0.032 14500.0 0.298 30.294 2.738 946.268 0.134 0.017 4.134 0.727 0.328 0.036 15000.0 0.297 29.867 2.814 945.978 0.141 0.018 4.196 0.761 0.347 0.039 15500.0 0.295 29.444 2.888 945.691 0.147 0.020 4.254 0.794 0.366 0.043 16000.0 0.293 29.024 2.962 945.402 0.153 0.021 4.310 0.827 0.385 0.047 16500.0 0.291 28.607 3.035 945.114 0.160 0.023 4.363 0.861 0.404 0.051 17000.0 0.289 28.194 3.107 944.825 0.166 0.025 4.413 0.894 0.422 0.055 17500.0 0.287 27.785 3.178 944.635 0.173 0.026 4.461 0.928 0.441 0.060 18000.0 0.286 27.379 3.248 944.245 0.179 0.028 4.506 0.961 0.461 0.064 18500.0 0.284 26.977 3.318 943,953 0.186 0.030 4.549 0.994 0.480 0.069 19000.0 0.282 26.578 3.386 943.661 0.193 0.032 4.591 1.027 0.499 0.074 19500.0 0.280 26.182 3.454 943.369 0.200 0.034 4.630 1.060 0.518 0.080 20000.0 0.279 25.790 3.520 943.074 0.207 0.036 4.667 1.093 0.537 0.085 20500.0 0.277 25.402 3.586 942.779 0.214 0.038 4.703 1.126 0.556 0.091 21000.0 0.275 25.017 3.651 942.483 0.221 0.040 4.737 1.159 0.575 0.097 21500.0 0.273 24.635 3.716 942.185 0.228 0.043 4.769 1.192 0.594 0.103 22000.0 0.272 24.257 3.779 941.887 0.235 0.045 4.800 1.224 0.613 0.109 22500.0 0.270 23.883 3.842 941.586 0.242 0.048 4.829 1.257 0.632 0.116 25000.0 0.261 22.060 4.142 940.065 0.279 0.061 4.955 1.416 0.726 0.151 27500.0 0.253 20.322 4.422 938.510 0.317 0.077 5.048 1.570 0.817 0.192 30000.0 0.244 18.668 4.682 936.919 0.356 0.095 5.113 1.720 0.904 0.238 32500.0 0.236 17.097 4.922 935.293 0.395 0.115 6.155 1.863 0.985 0.289 35000.0 0.228 15.606 5.143 933.628 0.434 0.137 5.175 2.000 1.060 0.344 37500.0 0.220 14.197 5,345 931.924 0.473 0.161 5.177 2.131 1.129 0.405 40000.0 0.212 12.868 5.528 930.180 0.512 0.188 5.164 2.254 1.191 0.469 42500.0 0.204 11.619 5.693 928.394 0.550 0.216 5.139 2.370 1.247 0.538 45000.0 0.196 10.449 5.840 926.566 0.587 0.245 5.103 2.477 1.296 0.610 47500.0 0.189 9.357 5.968 924.693 0.624 0.276 5.058 2.577 1.339 0.686 50000.0 0.181 8.343 6.079 922.776 0.659 0.308 5.009 2.668 1.375 0.765 52500.0 0.174 7.405 6.172 920.814 0.692 0.340 4,954 2.751 1.406 0.847 55000.0 0.167 6.542 6.249 918.806 0.724 0.373 4.896 2.826 1.432 0.931 57500.0 0.160 5.753 6.309 916.752 0.755 0.406 4.836 2.893 1.452 1.018 60000.0 0.154 5.035 6.354 914.653 0.783 0.439 4.776 2.951 1.468 1.106 62500.0 0.148 4.386 6.383 912.509 0.810 0.471 4.717 3.003 1.479 1.196 65000.0 0.141 3.804 6.399 910.322 0.835 0.502 4.658 3.047 1.488 1.287 67500.0 0.135 3.283 6.400 908.093 0.857 0.532 4.604 3.084 1.492 1.378 70000.0 0.130 2.822 6.390 905.824 0.878 0.561 4.551 3.115 1.495 1.470 AREVA Inc.
&ontroiLed Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page C-4 Table C.3 [ ] Exposure-Dependent 80% Void Isotopics (kg/MTU Initial)
Exposure bAWd/MTUf U-234 0-235 U-236 0-238 NP-237 PU-238 P0-239 P0-240 P0-241 P0-242 0.0 0.358 44.780 0.000 954.862 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.358 44.660 0.025 954.792 0.000 0.000 0.027 0.000 0.000 0.000 500.0 0.356 44.188 0.123 954.511 0.002 0.000 0.254 0.002 0.000 0.000 1000.0 0.353 43.608 0.244 864.161 0.006 0.000 0.540 0.009 0.001 0.000 1500.0 0.350 43.039 0.362 953.811 0.008 0.000 0.812 0.019 0.002 0.000 2000.0 0.348 42.479 0.478 953.461 0.012 0.000 1.071 0.033 0.004 0.000 2500.0 0.345 41.928 0.592 953.113 0.015 0.000 1.318 0.049 0.009 0.000 3000.0 0.343 41.387 0.703 952.765 0.019 0.001 1.554 0.069 0.013 0.000 3500.0 0.340 40.853 0.813 952.418 0.024 0.001 1.779 0.089 0.019 0.000 4000.0 0.339 40.328 0.920 952.072 0.029 0.001 1.994 0.111 0.027 0.001 4500.0 0.335 39.810 1.026 951.726 0.033 0.002 2.200 0.135 0.035 0.001 5000.0 0.333 39.298 1.130 951.381 0.039 0.002 2.397 0.161 0.046 0.001 5500.0 0.330 38.795 1.232 951.036 0.043 0.003 2.585 0.187 0.057 0.002 8000.0 0.329 39.299 1.332 950.693 0.049 0.003 2.765 0.215 0.070 0.003 6500.0 0.325 37.807 1.430 950.349 0.054 0.004 2.938 0.243 0.083 0.004 7000.0 0.323 37.323 1.527 950.007 0.060 0.004 3.103 0.272 0.098 0.004 7500.0 0.321 36.844 1.622 949.665 0.066 0.005 3.261 0.302 0.113 0.006 8000.0 0.319 36.371 1.716 949.324 0.072 0.006 3.412 0.333 0.129 0.007 5500.0 0.316 35.904 1.808 948.984 0.079 0.007 3.557 0.364 0.146 0.008 9000.0 0.314 35.442 1.899 948.644 0.085 0.008 3.695 0.396 0.164 0.010 9500.0 0.312 34.985 1.989 948.304 0.092 0.009 3.829 0.429 0.182 0.012 10000.0 0.310 34.534 2.077 947.966 0.098 0.010 3.955 0.462 0.201 0.013 10500.0 0.307 34.087 2.164 947.628 0.105 0.011 4.076 0.495 0.220 0.018 11000.0 0.305 33.645 2.249 947.290 0.112 0.013 4.192 0.529 0.240 0.018 11500.0 0.303 33.208 2.333 946.954 0.119 0.014 4.303 0.563 0.280 0.020 12000.0 0.301 32.775 2.416 946.617 0.126 0.015 4.410 0.597 0.280 0.023 12500.0 0.299 32.347 2.498 946.282 0.133 0.017 4.511 0.632 0.301 0.026 13000.0 0.297 31.923 2.578 945.946 0.141 0.019 4.608 0.667 0.322 0.029 13500.0 0.295 31.503 2.658 945.611 0.148 0.020 4.701 0.702 0.343 0.032 14000.0 0.293 31.087 2.736 945.277 0.155 0.022 4.789 0.737 0.364 0.035 14500.0 0.290 30.675 2.813 944.944 0.163 0.024 4.874 0.773 0.385 0.039 15000.0 0.288 30.268 2.889 944.610 0.170 0.028 4.955 0.809 0.406 0.042 15500.0 0.286 29.864 2.964 944.277 0.178 0.028 5.032 0.844 0.428 0.046 16000.0 0.284 29.463 3.038 943.944 0.185 0.030 5.105 0.880 0.449 0.050 16500.0 0.282 29.067 3.111 943.811 0.193 0.032 5.176 0.916 0.471 0.055 17000.0 0.281 28.674 3.183 943.278 0.201 0.034 5.243 0.952 0.492 0.059 17500.0 0.279 28.294 3.254 942.945 0.209 0.037 5.308 0.989 0.514 0.064 19000.0 0.277 27.899 3.324 942.611 0.217 0.039 5.370 1.025 0.535 0.069 18500.0 0.275 27.517 3.393 942.277 0.224 0.042 5.429 1.061 0.557 0.073 19000.0 0.273 27.138 3.461 941.943 0.222 0.044 5.486 1.097 0.578 0.079 19500.0 0.271 26.763 3.528 941.607 0.240 0.047 5.541 1.133 0.600 0.084 20000.0 0.269 26.391 3.595 941.271 0.248 0.050 5.593 1.169 0.621 0.090 20500.0 0.267 26.023 3.660 940.934 0.256 0.053 5.644 1.205 0.643 0.095 21000.0 0.205 25.659 3.725 940.596 0.264 0.056 5.692 1.240 0.664 0.101 21500.0 0.263 25.297 3.788 940.258 0.272 0.059 5.739 1.278 0.686 0.107 22000.0 0.262 24.940 3.851 939.918 0.281 0.062 5.784 1.312 0.707 0.113 22500.0 0.260 24.585 3.913 939.577 0.289 0.085 5.827 1.347 0.728 0.120 23000.0 0.258 24.235 3.974 939.234 0.297 0.069 5.869 1.283 0.750 0.126 23500.0 0.256 23.887 4.034 938.891 0.305 0.072 5.909 1.418 0.771 0.133 24000.0 0.254 23.543 4.093 939.547 0.313 0.076 5.948 1.453 0.792 0.140 24500.0 0.252 23.202 4.152 938.201 0.322 0.079 5.985 1.488 0.813 0.147 25000.0 0.251 22.885 4.210 937.854 0.330 0.083 6.020 1.523 0.834 0.155 27500.0 0.242 21.229 4.485 936.100 0.372 0.104 6.179 1.894 0.938 0.194 30000.0 0.233 19.673 4.740 934.314 0.415 0.127 6.308 1.861 1.039 0.237 32500.0 0.224 18.198 4.976 932.496 0.457 0.152 6.409 2.022 1.134 0.294 35000.0 0.216 16.799 5.192 930.646 0.500 0.181 8.487 2.179 1.220 0.236 37500.0 0.208 10.477 5.388 929.764 0.542 0.211 6.544 2.329 1.311 0.390 40000.0 0.200 14.229 5.567 926.848 0.584 0.244 6.582 2.471 1.390 0.448 42500.0 0.193 13.053 5.727 924.899 0.625 0.279 6.606 2.608 1.484 0.510 45000.0 0.185 11.948 5.869 922.917 0.665 0.316 6.615 2.738 1.533 0.574 47500.0 0.178 10.912 5.995 920.902 0.704 0.384 8.813 2.861 1.599 0.641 50000.0 0.171 9.943 6.104 919.954 0.741 0.394 6.602 2.976 1.653 0.710 52500.0 0.185 9.040 6.197 916.773 0.777 0.435 6.582 3.084 1.704 0.782 55000.0 0.158 8.199 6.275 914.860 0.811 0.476 6.556 3.185 1.751 0.856 57500.0 0.152 7.420 6.338 912.514 0.844 0.519 6.524 3.279 1.792 0.931 50000.0 0.147 6.699 6.288 910.238 0.875 0.581 8.489 3.365 1.829 1.009 62500.0 0.141 6.035 6.424 909.132 0.903 0.604 6.450 3.444 1.861 1.088 65000.0 0.126 5.424 6.448 905.997 0.930 0.646 6.410 3.515 1.889 1.168 67500.0 0.131 4.865 6.460 903.633 0.955 0.697 6.368 3.582 1.913 1.250 70000.0 0.126 4.354 6.481 901.343 0.978 0.728 6.326 3.641 1.934 1.3322 AREVA Inc.
Contiro led Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page C-5 Table C.4 [ J Exposure-Dependent 0% Void Isotopics (kg/MTU Initial)
Exposure MWd/M4TU 0-234 0-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 P0-242 0.0 0.358 44.783 0.000 954.859 0.000 0.000 0.000 0.O000 0.000 0.000 100.0 0.358 44.662 0.023 954.806 0.000 0.000 0.021 0.000 0.000 0.000 500.0 0.356 44.185 0.113 954.590 0.002 0.000 0.198 0.002 0.000 0.000 1000.0 0.354 43.597 0.225 954.321 0.004 0.000 0.421 0.007 0.000 0.000 1500.0 0.352 43.017 0.334 954.052 0.006 0.000 0.634 0.015 0.001 0.000 2000.0 0.350 42.445 0.442 953.783 0.008 0.000 0.836 0.026 0.002 0.000 2500.0 0.348 41.880 0.548 953.514 0.011 0.000 1.029 0.040 0.005 0.000 3000.0 0.346 41.323 0.653 953.245 0.014 0.000 1.223 0.056 0.008 0.000 3500.0 0.344 40.773 0.755 952.978 0.017 0.001 1.389 0.074 0.012 0.000 4000.0 0.342 40.229 0.857 952.708 0.020 0.001 1.557 0.094 0.016 0.000 4500.0 0.340 39.692 0.956 952.439 0.023 0.001 1.716 0.115 0.022 0.001 5000.0 0.338 39.161 1.055 952.171 0.027 0.001 1.869 0.137 0.029 0.001 5500.0 0.336 38.636 1.152 951.903 0.030 0.001 2.014 0.160 0.037 0.001 6000.0 0.334 38.117 1.247 951.636 0.034 0.002 2.153 0.185 0.045 0.002 6500.0 0.332 37.603 1.342 951.368 0.038 0.002 2.285 0.210 0.055 0.003 7000.0 0.331 37.095 1.435 951.101 0.042 0.002 2.411 0.236 0.065 0.003 7500.0 0.329 36.591 1.526 950.834 0.046 0.003 2.531 0.263 0.078 0.004 6000.0 0.327 36.093 1.617 950.588 0.051 0.003 2.645 0.291 0.088 0.005 8500.0 0.325 35.600 1.706 950.301 0.055 0.004 2.754 0.319 0.100 0.006 9000.0 0.323 35.111 1.794 950.035 0.060 0.004 2.858 0.347 0.113 0.007 9500.0 0.321 34.627 1.881 949.768 0.064 0.005 2.957 0.377 0.127 0.009 10000.0 0.319 34.148 1.967 949.502 0.069 0.006 3.051 0.406 0.141 0.010 10500.0 0.318 33.673 2.052 949.236 0.074 0.006 3.141 0.43"6 0.156 0.012 11000.0 0.316 33.203 2.136 548.970 0.079 0.007 3.226 0.466 0.171 0.014 11500.0 0.314 32.736 2.218 948.704 0.084 0.008 3.306 0.497 0.186 0.018 12000.0 0.312 32.274 2.300 548.438 0.090 0.009 3.383 0.528 0.202 0.018 12500.0 0.310 31.916 2.381 948.173 0.095 0.010 3.456 0.559 0.219 0.021 13000.0 0.309 31.362 2.460 947.906 0.100 0.011 3.524 0.590 0.235 0.023 13500.0 0.307 30.912 2.539 947.640 0.106 0.011 3.589 0.622 0.251 0.026 14000.0 0.305 30.466 2.816 947.375 0.111 0.013 3.681 0.653 0.268 0.029 14500.0 0.303 30.023 2.693 .947.109 0.117 0.014 3.709 0.655 0.285 0.032 15000.0 0.302 29.584 2.769 946.844 0.123 0.015 3.763 0.717 0.302 0.036 15500.0 0.300 29.148 2.844 946.579 0.128 0.016 3.814 0.749 0.319 0.039 16000.0 0.298 28.716 2.918 946.315 0.134 0.017 3.862 0.782 0.336 0.043 16500.0 0.296 28.297 2.991 946.050 0.140 0.019 3.906 0.814 0.353 0.047 17000.0 0.295 27.862 3.063 545.786 0.146 0.020 3.948 0.846 0.370 0.051 17500.0 0.293 27.439 3.134 945.522 0.151 0.021 3.987 0.878 0.387 0.055 18000.0 0.291 27.020 3.205 945.259 0.157 0.023 4.023 0.911 0.404 0.060 19500.0 0.290 26.604 3.274 944.995 0.163 0.024 4.057 0.943 0.421 0.065 19000.0 0.288 26.191 3.343 944.731 0.169 0.026 4.088 0.975 0.438 0.069 19500.0 0.296 25.782 3.412 944.466 0.175 0.027 4.117 1.007 0.458 0.075 20000.0 0.295 25.375 3.479 944.201 0.181 0.029 4.144 1.039 0.471 0.090 20500.0 0.283 24.972 3.546 943.936 0.197 0.031 4.169 1.071 0.488 0.095 21000.0 0.281 24.571 3.611 943.669 0.193 0.033 4.193 1.103 0.505 0.091 21500.0 0.280 24.174 3.676 943.402 0.199 0.034 4.215 1.134 0.821 0.097 22000.0 0.278 23.780 3.741 943.133 0.206 0.036 4.235 1.166 0.538 0.103 22500.0 0.276 23.390 3.904 943.864 0.212 0.038 4.254 1.197 0.554 0.109 23000.0 0.275 23.002 3.867 942.593 0.218 0.040 4.272 1.228 0.571 0.116 23500.0 0.273 22.618 3.929 942.320 0.225 0.042 4.288 1.259 0.587 0.123 25000.0 0.268 21.486 4.110 941.494 0.244 0.049 4.331 1.350 0.635 0.144 27500.0 0.260 19.864 4.396 940.098 0.278 0.062 4.380 1.498 0.714 0.194 30000.0 0.252 17.925 4.663 938.643 0.312 0.077 4.405 1.640 0.789 0.230 32500.0 0.244 16.270 4.911 937.157 0.347 0.093 4.410 1.778 0.858 0.281 35000.0 0.236 14.699 5.140 935.627 0.383 0.111 4.397 1.904 0.922 0.338 37500.0 0.228 13.213 5.350 934.052 0.418 0.131 4.369 2.028 0.978 0.400 40000.0 0.219 11.812 8.840 932.428 0.454 0.153 4.330 2.138 1.029 0.467 42500.0 0.212 10.499 8.711 930.753 0.489 0.176 4.281 2.243 1.072 0.539 45000.0 0.204 9.273 5.862 929.025 0.524 0.201 4.225 2.340 1.109 0.616 47500.0 0.196 8.137 5.994 927.241 0.558 0.226 4.163 2.428 1.139 0.697 50000.0 0.188 7.090 6.107 925.399 0.591 0.253 4.098 2.507 1.164 0.783 52500.0 0.180 6.133 6.201 923.497 0.622 0.280 4.032 2.577 1.183 0.872 58000.0 0.173 5.285 6.275 921.534 0.652 0.307 3.965 2.638 1.196 0.964 57500.0 0.165 4.485 6.332 919.509 0.681 0.333 3.900 2.690 1.206 1.080 60000.0 0.158 3.790 6.370 917.423 0.707 0.359 3.937 2.734 1.211 1.157 62500.0 0.151 3.179 6.392 915.277 0.731 0.385 3.778 2.771 1.213 1.257 65000.0 0.144 2.646 6.397 913.073 0.753 0.408 3.723 2.800 1.212 1.357 67800.0 0.137 2.187 6.388 910.813 0.773 0.431 3.873 2.822 1.209 1.458 70000.0 0.130 1.796 6.366 908.503 0.790 0.452 3.627 2.839 1.204 1.559 AREVA Inc.
ControIIed LDocurnent Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page C-6 Table C.5 [ ] Exposure-Dependent 40% Void Isotopics (kg/MTU Initial)
Exposure k49d/MTU U-234 U-235 U-236 0-238 NP-237 P0-238 P0-239 PU-240 P0-241 P0-242 0.0 0.358 44.783 0.000 954.859 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.358 44.563 0.024 954.708 0.000 0.000 0.024 0.000 0.000 0.000 000.0 0.356 44.188 0.118 954.553 0.002 0.000 0.224 0.002 0.000 0.000 1000.0 0.304 43.602 0.233 954.247 0.004 0.000 0.476 0.008 0.000 0.000 1500.0 0.351 43.027 0.347 953.941 0.007 0.000 0.716 0.017 0.001 0.000 2000.0 0.345 42.460 0.458 953.635 0.010 0.000 0.545 0.030 0.003 0.000 2500.0 0.347 41.901 0.565 953.330 0.013 0.000 1.163 0.045 0.006 0.O000 3000.0 0.345 41.351 0.670 953.025 0.016 0.000 1.371 0.062 0.010 0.000 3500.0 0.342 40.808 0.781 952.721 0.020 0.001 1.569 0.082 0.015 0.000 4000.0 0.340 40.273 0.885 952.416 0.023 0.001 1.759 0.103 0.021 0.001 4500.0 0.338 39.745 0.987 952.112 0.027 0.001 1.939 0.126 0.028 0.001 5000.0 0.336 38.223 1.068 951.809 0.032 0.002 2.112 0.150 0.037 0.001 5500.0 0.334 38.708 1.187 951.505 0.036 0.002 2.277 0.175 0.046 0.002 6000.0 0.332 38.199 1.284 951.202 0.040 0.002 2.435 0.201 0.057 0.002 6500.0 0.329 37.696 1.380 950.900 0.045 0.003 2.565 0.228 0.068 0.003 7000.0 0.327 37.199 1.475 950.597 0.050 0.003 2.729 0.256 0.080 0.004 7500.0 0.325 36.708 1.568 950.295 0.055 0.004 2.866 0.284 0.094 0.005 8000.0 0.323 36.222 1.660 949.994 0.060 0.004 2.998 0.313 0.105 0.006 8500.0 0.321 35.742 1.750 949.692 0.065 0.005 3.123 0.343 0.123 0.007 9000.0 0.319 35.266 1.840 949.391 0.071 0.006 3.242 0.373 0.138 0.009 9500.0 0.317 34.796 1.927 949.090 0.076 0.007 3.357 0.404 0.154 0.010 10000.0 0.315 34.331 2.014 948.790 0.082 0.007 3.466 0.435 0.171 0.012 10500.0 0.313 33.870 2.099 948.489 0.088 0.008 3.569 0.467 0.188 0.014 11000.0 0.311 33.414 2.183 948.188 0.094 0.009 3.669 0.499 0.206 0.016 11500.0 0.309 32.963 2.266 947.889 0.100 0.010 3.763 0.531 0.224 0.019 12000.0 0.307 32.516 2.346 947.589 0.106 0.011 3.853 0.563 0.242 0.021 12000.0 0.305 32.073 2.429 947.289 0.112 0.013 3.938 0.596 0.261 0.024 13000.0 0.303 31.635 2.509 946.990 0.119 0.014 4.020 0.829 0.280 0.027 13500.0 0.301 31.201 2.587 946.690 0.125 0.015 4.097 0.662 0.299 0.030 14000.0 0.299 30.771 2.665 946.391 0.132 0.016 4.170 0.696 0.318 0.033 14500.0 0.297 30.344 2.741 946.093 0.138 0.018 4.240 0.729 0.338 0.037 15000.0 0.296 29.922 2.817 945.794 0.145 0.019 4.306 0.763 0.357 0.040 15500.0 0.294 29.503 2.891 945.496 0.151 0.021 4.368 0.797 0.377 0.044 16000.0 0.292 29.088 2.965 945.198 0.158 0.022 4.427 0.831 0.397 0.048 16500.0 0.290 28.677 3.037 944.900 0.164 0.024 4.482 0.865 0.417 0.052 17000.0 0.268 28.269 3.109 944.603 0.171 0.026 4.534 0.899 0.436 0.057 17500.0 0.286 27.865 3.180 944.306 0.178 0.028 4.563 0.933 0.456 0.062 18000.0 0.285 27.464 3.249 944.009 0.185 0.029 4.629 0.967 0.475 0.066 16500.0 0.283 27.066 3.318 943.712 0.192 0.031 4.672 1.001 0.495 0.072 19000.0 0.281 26.671 3.386 943.416 0.198 0.033 4.713 1.035 0.514 0.077 19000.0 0.279 26.280 3.484 943.119 0.205 0.035 4.751 1.069 0.534 0.082 20000.0 0.277 25.892 3.520 942.822 0.212 0.038 4.787 1.102 0.553 0.088 20500.0 0.276 25.507 3.585 942.525 0.219 0.040 4.821 1.136 0.572 0.094 21000.0 0.274 25.125 3.650 942.227 0.226 0.042 4.852 1.170 0.591 0.100 21500.0 0.372 24.747 3.714 941.929 0.233 0.044 4.882 1.203 0.610 0.106 22000.0 0.270 24.372 3.777 941.629 0.241 0.047 4.910 1.236 0.629 0.112 22000.0 0.269 24.000 3.839 941.329 0.248 0.049 4.936 1.270 0.647 0.119 23000.0 0.267 23.631 3.901 941.028 0.355 0.052 4.961 1.302 0.666 0.126 23500.0 0.265 23.265 3.961 940.726 0.262 0.055 4.984 1.335 0.685 0.133 24000.0 0.264 22.903 4.021 940.423 0.270 0.057 5.006 1.368 0.703 0.140 24500.0 0.262 22.544 4.080 940.118 0.277 0.060 5.027 1.400 0.721 0.148 25000.0 0.260 22.188 4.138 939.812 0.284 0.063 5.046 1.432 0.740 0.155 25500.0 0.258 21.836 4.196 939.505 0.292 0.066 5.064 1.464 0.758 0.163 27000.0 0.252 20.458 4.417 938.262 0.322 0.079 5.126 1.589 0.829 0.196 30000.0 0.243 18.809 4.677 936.677 0.360 0.097 5.181 1.739 0.915 0.242 32500.0 0.235 17.241 4.917 935.055 0.399 0.117 5.213 1.883 0.996 0.293 30000.0 0.227 15.753 5.138 933.396 0.438 0.140 5.226 2.020 1.071 0.349 37500.0 0.219 14.344 5.341 931.699 0.476 0.164 5.222 2.150 1.140 0.409 40000.0 0.211 13.014 5.525 929.961 0.515 0.190 5.204 2.273 1.202 0.474 42000.0 0.203 11.763 5.690 928.182 0.553 0.218 5.174 2.387 1.258 0.542 45000.0 0.196 10.590 5.838 926.360 0.590 0.247 5.135 2.494 1.307 0.615 47500.0 0.188 9.494 5.967 924.496 0.626 0.278 5.087 2.592 1.349 0.690 50000.0 0.181 8.474 6.079 922.586 0.661 0.310 5.034 2.883 1.386 0.769 02000.0 0.174 7.530 6.174 920.632 0.694 0.342 4.977 2.764 1.416 0.851 59000.0 0.167 6.661 6.253 918.633 0.726 0.375 4.917 2.838 1.442 0.935 57500.0 0.160 5.860 6.310 916.088 0.706 0.408 4.856 2.904 1.461 1.022 60000.0 0.104 5.139 6.361 914.497 0.785 0.440 4.795 2.962 1.477 1.110 62500.0 0.147 4.482 6.392 912.363' 0.812 0.472 4.734 3.012 1.488 1.200 65000.0 0.141 3.891 6.409 910.185 0.836 0.504 4.670 3.055 1.496 1.291 67500.0 0.135 3.363 6.413 907.960 0.859 0.534 4.618 3.091 1.500 1.382 70000.0 0.130 3.894 6.404 905.705 0.879 0.562 4.564 3.122 1.502 1.474 AREVA Inc.
Con dDocumernt Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 1OXM Fuel Page C-7 Table C.6 [ J Exposure-Dependent 80% Void Isotopics (kg/MTU Initial)
Exposure MWd/14TU Ul-234 U-235 U-236 U-238 N9-237 PU1-238 PU1-239 PU1-240 91U-241 PU3-2 42 0.0 0.358 44.783 0.000 954.859 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.358 44.664 0.025 954.789 0.000 0.000 0.027 0. 000 0.000 0.000 500.0 0.356 44.192 0.123 954.505 0.002 0.000 0.256 0. 002 0.000 0.000 1000.0 0.353 43.612 0.244 954.151 0.005 0.000 0.545 0. 009 0.001 0.000 1500.0 0.350 43.042 0.363 953.798 0.006 0.000 0. 820 0. 019 0.002 0.000 2000.0 0.348 42.483 0.479 953,445 0.012 0.000 1.082 0.033 0.004 0.000 2500.0 0.345 41.933 0,593 953.092 0.016 0.000 1.333 0,049 0.008 0.000 3000.0 0.342 41.392 0.705 952.740 0.020 0.001 1.572 0.068 0.013 0.000 3500.0 0.340 40.858 0.814 952.389 0.024 0.001 1.801 0. 069 0.019 0.000 4000.0 0.337 40.333 0.922 952.038 0.029 0.001 2. 020 0.111 0.027 0.001 4500.0 0.335 39.816 1.028 951.687 0.033 0.002 2.230 0. 135 0.036 0.001 5000.0 0.332 39.306 1.132 951.337 0.038 0.002 2. 430 0.161 0.046 0.001 5500.0 0.330 38.803 1.234 950.987 0.044 0.003 2.623 0. 187 0.058 0.002 5000.0 0.328 38.306 1.334 950.638 0.049 0.003 2.807 0.215 0.070 0.003 5500.0 0.325 37.817 1.433 950.289 0.055 0.004 2.984 0.243 0.084 0.004 1000.0 0.323 37.333 1.530 849.940 0.061 0.005 3.154 0.272 0.099 0.005 7500.0 0.320 36.856 1.626 949.592 0.067 0.005 3.317 0.302 0.114 0.006 8000.0 0.318 36,384 1.720 949,244 0.074 0.006 3.473 0.333 0.131 0.007 8500.0 0.316 35,918 1.812 948.897 0.080 0.007 3. 622 0.364 0.148 0.008 9000.0 0.314 35.458 1.903 948.550 0.087 0.008 3.766 0.396 0.166 0.010 9500.0 0.311 35.003 1.993 948.203 0.093 0.009 3. 903 0. 428 0.185 0.012 10000.0 0.309 34.553 2.081 947.857 0.100 0.010 4 .035 0.461 0.204 0.014 10500.0 0.307 34.108 2.168 947.511 0.107 0.012 4 .162 0. 485 0.224 0.016 11000.0 0.305 33.668 2.254 947.165 0.114 0.013 4 .283 0. 528 0.244 0.018 11500.0 0.302 33.233 2.338 946.820 0.122 0.014 4 .399 0.562 0.265 0.021 12000.0 0.300 32.803 2,421 946.475 0.129 0.018 4 .511 0. 597 0.286 0.023 12500.0 0.298 32.378 2,503 946.130 0.136 0.017 4 .618 0. 632 0.307 0.026 13000.0 0.296 31.957 2.584 945.785 0.144 0.019 4 .720 0. 667 0.328 0.029 13500.0 0.294 31.540 2.663 945.441 0.151 0.021 4 .818 0.702 0.350 0.032 14000.0 0.292 31.128 2.741 945.097 0.158 0.023 4 .912 0.737 0.372 0.036 14500.0 0.290 30.719 2.819 944.753 0.167 0.025 5.001 0.773 0.394 0.040 15000.0 0.285 30.315 2.695 954.409 0.174 0.027 5.087 0 .809 0.416 0.043 15500.0 0.285 29.915 2.970 944.066 0.182 0.029 5.169 0.845 0.438 0.047 15000.0 0.283 29.519 3,043 943.723 0.190 0.031 5.247 0.882 0.461 0.052 15500.0 0.281 29.127 3.116 943.380 0.198 0.033 5.321 0. 918 0. 483 0.056 17000.0 0.279 28.738 3.188 943.038 0.206 0.036 5.392 0. 954 0.506 0.060 17500.0 0.277 28.354 3.259 942.696 0.214 0.038 5.460 0.991 0.528 0.065 18000.0 0.275 27.973 3.328 942.354 0.222 0.041 5.524 1.028 0.550 0.070 18500.0 0.274 27.595 3.397 942.012 0.230 0.043 5.585 1.064 0.572 0.075 19000.0 0.272 27.221 3.465 941.671 0.238 0.046 5.643 1.101 0.595 0.081 19500.0 0.270 26.850 3.532 941.330 0.246 0.049 5.698 1.138 0.617 0.086 20000.0 0.268 26.483 3.598 940.888 0.255 0.052 5.751 1.175 0.638 0.092 20500.0 0.266 26.119 3.663 940.647 0.263 0.055 5.801 1.211 0.660 0.097 21000.0 0.264 25.758 3.727 940.305 0.271 0.058 5.848 1.248 0.682 0.103 21500.0 0.262 25.401 3.790 939.964 0.279 0.061 5.894 1.285 0.703 0.110 22000.0 0.2 60 25.047 3.852 939.621 0.287 0.064 5.937 1.321 0.725 0.116 22500.0 0.258 24.696 3.914 939.279 0.295 0.068 5.978 1.357 0.746 0.123 23000.0 0.257 24.348 3.975 938.836 0.303 0.071 6.017 1.354 0.767 0.129 23500.0 0.255 24.003 4.034 938.591 0.312 0.075 6. 055 1. 430 0.789 0.136 24000.0 0.253 23.662 4.093 938.247 0.320 0.078 6.050 1.466 0.810 0.143 24500.0 0.251 23,324 4.152 937.901 0.328 0.082 6.125 1.501 0.831 0.150 25000.0 0.249 22.989 4.209 937.554 0.336 0.086 6.157 1,537 0.851 0.158 25500.0 0.248 22.657 4.265 937.206 0.345 0.090 6.188 1 .572 0.872 0.165 25000.0 0.246 22.329 4,321 936.858 0.353 0.094 6.218 1. 607 0.893 0.173 28500.0 0.244 22.004 4.376 936.508 0.361 0.098 6.247 1 .642 0.913 0.181 27000.0 0.242 21.681 4.430 936.157 0.370 0.102 6.274 1 .677 0.933 0.189 27500.0 0.240 21.362 4.483 935.805 0.378 0.107 6.300 1.712 0.954 0.197 28000.0 0.239 21.047 4.536 835.451 0.386 0.111 6.325 1.746 0.974 0.206 28500.0 0.237 20.734 4.587 935,097 0.395 0.116 6.349 1.780 0.9594 0.214 30000.0 0.232 19.814 4.738 934.025 0.420 0.130 6.415 1.881 1 .053 0.241 32500.0 0.223 18.344 4.973 832.213 0.462 0.156 6.504 2.044 1.148 0.288 35000.0 0.218 15.949 5.188 930.369 0.504 0.184 6.572 2.201 1 .239 0.339 37500.0 0.207 15.628 5.386 928.493 0.546 0.214 6.620 2.351 1 .325 0.394 40000.0 0.200 14.381 5,564 926.584 0.588 0.247 6.651 2.494 1 .405 0.452 42500.0 0.192 13.204 5,725 924.642 0.628 0.282 6.668 2. 631 1.479 0.514 45000.0 0.185 12.097 5,869 922.668 0.668 0.319 6.672 2. 760 1.547 0.578 47500.0 0 .178 11.059 5,995 920.660 0.707 0.357 6. 665 2. 882 1.610 0.645 50000.0 0.171 10.086 6.105 918.619 0.744 0.397 6.649 2. 997 1 .667 0.714 52500.0 0.164 9,179 6,200 916.546 0.780 0.438 5.626 3 .104 1.718 0.786 55000.0 0.158 8.333 6.279 914.441 0.814 0.479 6.596 3.203 1.765 0.860 57500.0 0.152 7.548 6.344 912.304 0.846 0.522 6.562 3.296 1.606 0.935 60000 .0 0.146 6.821 6.396 910.136 0.877 0.564 6.524 3.381 1.842 1.013 82500.0 0.141 6.151 6.433 907.938 0.906 0.606 6.483 3.459 1 .874 1.092 55000.0 0.136 5.534 6.459 905.711 0.932 0.649 6.441 3.531 1 .902 1.172 87500.0 0.131 4.968 6.473 903.456 0.957 0.690 6.397 3.596 1.926 1.253 70000.0 0.126 4.450 6.475 901.174 0.980 0.731 6.353 3. 654 1.846 1.336 AREVA Inc.
Cont oiled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page C-8 Table C.7 [ ] Exposure-Dependent 0% Void Isotopics (kgIMTU Initial)
EXposure MWd/MTU 0-234 U-235 U-236 0-238 NP-237 P0-238 PU-239 P0-240 P0-241 PU-242 0.0 0.352 43.987 0.000 955.661 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.352 43.867 0.022 955.609 0.000 0.000 0.019 0.000 0.000 0.000 500.0 0.350 43.389 0.112 955.400 0.002 0.000 0.168 0.001 0.000 0.000 1000.0 0.348 42.800 0.222 955.138 0.003 0.000 0.405 0.008 0.000 0.000 1500.0 0.348 42.219 0.330 954.877 0.006 0.000 0.612 0.015 0.001 0.000 2000.0 0.344 41.646 0.437 954.616 0.008 0.000 0.809 0.026 0.002 0.000 2500.0 0.342 41.081 0.542 954.356 0.010 0.000 0.996 0.039 0.004 0.000 3000.0 0.340 40.522 0.645 954.096 0.013 0.000 1.174 0.055 0.007 0.000 3500.0 0.338 39.871 0.747 953.837 0.016 0.000 1.343 0.073 0.011 0.000 4000.0 0.336 38.426 0.847 953.578 0.019 0.001 1.505 0.092 0.016 0.000 4500.0 0.335 38.887 0.946 953.319 0.022 0.001 1.658 0.113 0.021 0.001 5000.0 0.333 38.354 3.043 953.062 0.025 0.001 1.804 0.135 0.027 0.001 5500.0 0.331 37.827 1.139 952.804 0.029 0.001 1.943 0.158 0.035 0.001 6000.0 0.329 37.305 1.233 952.548 0.032 0.002 2.074 0.182 0.043 0.002 6500.0 0.327 36.789 1.327 952.292 0.036 0.002 2.200 0.207 0.052 0.002 7000.0 0.325 36.278 1.418 952.036 0.040 0.002 2.318 0.233 0.062 0.003 7500.0 0.324 35.772 1.509 951.781 0.044 0.003 2.431 0.260 0.072 0.004 8000.0 0.322 35.271 1.599 951.526 0.048 0.003 2.539 0.287 0.083 0.005 8500.0 0.320 34.775 1.587 951.272 0.052 0.004 2.540 0.315 0.095 0.006 9000.0 0.318 34.283 1.775 951.018 0.056 0.004 2.737 0.343 0.108 0.007 9500.0 0.316 33.796 1.861 950.764 0.061 0.005 2.829 0.372 0.120 0.008 10000.0 0.315 33.313 1.946 950.511 0.065 0.005 2.515 0.402 0.134 0.010 10500.0 0.313 32.834 2.030 950.258 0.070 0.006 2.997 0.431 0.148 0.012 11000.0 0.311 32.360 2.113 950.005 0.074 0.006 3.075 0.461 0.162 0.013 11500.0 0.310 31.889 2.195 949.753 0.079 0.007 3.148 0.492 0.177 0.015 12000.0 0.308 31.423 2.276 949.501 0;084 0.008 3.217 0.523 0.292 0.018 12500.0 0.306 30.961 2.356 949.250 0.089 0.008 3.282 0.553 0.207 0.020 13000.0 0.304 30.502 2.435 948.998 0.094 0.010 3.343 0.585 0.222 0.022 23500.0 0.303 30.047 2.513 948.748 0.099 0.010 3.401 0.616 0.238 0.025 14000.0 0.301 29.595 2.590 948.498 0.104 0.011 3.454 0.648 0.253 0.028 14500.0 0.299 29.147 2.666 948.248 0.109 0.012 3.504 0.679 0.269 0.031 15000.0 0.298 28.702 2.741 947.989 0.114 0.013 3.551 0.711 0.285 0.034 15500.0 0.286 28.260 2.816 947.750 0.119 0.014 3.594 0.743 0.301 0.038 16000.0 0.295 27.822 2.890 947.502 0.125 0.015 3.634 0.775 0.317 0.041 16500.0 0.293 27.386 2.962 947.255 0.130 0.017 3.671 0.807 0.332 0.045 17000.0 0.291 28.954 3.034 947.008 0.135 0.018 3.705 0.839 0.348 0.049 17500.0 0.290 25.525 3.106 946.760 0.140 0.019 3.737 0.871 0.364 0.053 18000.0 0.288 26.098 3.176 946.513 0.146 0.020 3.766 0.903 0.380 0.057 18500.0 0.287 25.675 3.246 946.266 0.151 0.021 3.793 0.935 0.395 0.062 19000.0 0.285 25.255 3.315 946.018 0.157 0.023 3.818 0.966 0.411 0.067 19500.0 0.283 24.838 3.383 945.769 0.162 0.024 3.841 0.998 0.426 0.072 20000.0 0.282 24.424 3.450 945.520 0.168 0.026 3.862 1.030 0.442 0.077 20500.0 0.280 24.013 3.517 945.269 0.173 0.027 3.982 1.061 0.457 0.082 21000.0 0.278 23.606 3.583 945.017 0.179 0.029 3.900 1.092 0.473 0.088 22500.0 0.274 22.403 3.776 944.253 0.196 0.034 3.948 1.185 0.520 0.106 25000.0 0.266 20.464 4.083 942.950 0.226 0.044 4.004 1.336 0.596 0.140 27500.0 0.258 18.608 4.370 941.608 0.257 0.055 4.034 1.491 0.670 0.190 30000.0 0.250 16.837 4.639 940.224 0.289 0.068 4.041 1.620 0.739 0.226 32500.0 0.242 15.153 4.888 938.795 0.322 0.082 4.030 1.753 0.852 0.278 35000.0 0.234 13.555 5.117 537.318 0.355 0.098 4.003 1.879 0.859 0.335 37500.0 0.226 12.048 5.327 935.758 0.389 0.115 3.963 1.998 0.910 0.398 40000.0 0.318 10.632 5.517 934.204 0.423 0.135 3.913 2.108 0.954 0.468 42500.0 0.210 9.311 5.687 932.561 0.456 0.156 3.855 2.209 0.991 0.543 45000.0 0.202 8.087 5.835 930.854 0.489 0.178 3.792 2.302 1.021 0.623 47500.0 0.194 6.961 5.963 929.081 0.521 0.201 3.726 2.385 1.045 0.709 50000.0 0.185 5.936 6.070 927.239 0.552 0.224 3.859 2.458 1.064 0.799 52500.0 0.177 5.013 6.157 925.324 0.582 0.248 3.592 2.522 1.077 0.894 55000.0 0.169 4.190 6.222 923.336 0.610 0.271 3.527 2.576 1.085 0.992 57500.0 0.161 3.466 6.268 921.274 0.636 0.294 3.466 2.621 1.089 1.094 60000.0 0.154 2.839 6.294 919.139 0.660 0.317 3.409 2.658 1.090 1.198 62500.0 0.146 2.302 6.303 916.935 0.682 0.338 3.357 2.687 1.089 1.304 65000.0 0.138 1.849 6.295 914.666 0.701 0.358 3.310 2.708 1.085 1.411 67500.0 0.131 1.474 6.272 912.335 0.718 0.376 3.269 2.724 1.081 1.518 70000.0 0.124 1.166 6.236 909.952 0.733 0.393 3.233 2.734 1.075 1.625 AREVA Inc.
Cotrolie] Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page C-9 Table C.8 [ ] Exposure-Dependent 40%
Void Isotopics (kgIMTU Initial)
Exposure M4Wd/MTO 0-234 0-235 0-236 0-238 N2-237 PU-238 P0-239 PU-240 P0-241 P0J-242 0.0 0.352 43.987 0.000 955.661 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.351 43.867 0.023 955.602 0.000 0.O000 0.021 0.000 0.000 0.000 500.0 0.350 43.391 0.116 9555.363 0.002 0.000 0.213 0.002 0.000 0.000 1000.0 0.347 42.805 0.231 955.065 0.004 0.000 0.459 0.007 0.000 0.000 1500.0 0.345 42.228 0.343 954.768 0.007 0.000 0.693 0.017 0.001 0.000 2000.0 0.343 41.660 0.453 954.471 0.008 0.000 0.916 0.029 0.003 0.000 2500.0 0.341 41.100 0.561 954.175 0.012 0.000 1.128 0.044 0.006 0.000 3000.0 0.339 40.548 0.667 953.880 0.015 0.000 1.329 0.061 0.008 0.000 3500.0 0.337 40.004 0.772 953.586 0.019 0.001 1.521 0.080 0.014 0.000 4000.0 0.335 39.467 0.875 953.292 0.022 0.001 1.704 0.101 0.020 0.001 4500.0 0.332 38.937 0.976 952.999 0.026 0.001 1.878 0.124 0.027 0.001 5000.0 0.330 38.413 1.075 952.706 0.030 0.001 2.043 0.148 0.035 0.001 5500.0 0.328 37.896 1.173 952.415 0.034 0.002 2.200 0.173 0.044 0.002 6000.0 0.326 37.385 1.269 902.124 0.038 0.002 2.350 0.198 0.094 0.002 6500.0 0.324 36.875 1.364 551.833 0.043 0.003 2.493 0.220 0.069 0.003 7000.0 0.322 36.380 1.458 951.044 0.047 0.002 2.628 0.253 0.077 0.004 7900.0 0.320 35.886 1.550 951.256 0.052 0.004 2.757 0.281 0.090 0.005 6000.0 0.318 35.397 1.640 950.567 0.057 0.004 2.880 0.311 0.103 0.006 6500.0 0.318 34.813 1.730 950.680 0.062 0.005 2.996 0.340 0.117 0.007 9000.0 0.314 34.435 1.815 950.353 0.067 0.005 3.107 0.370 0.132 0.008 9500.0 0.313 33.961 1.905 950.106 0.072 0.006 3.212 0.401 0.148 0.010 10000.0 0.311 33.492 1.990 949.821 0.077 0.007 3.312 0.432 0.164 0.012 10500.0 0.305 33.028 2.079 949.535 0.083 0.008 3.407 0.463 0.180 0.014 11000.0 0.307 32.568 2.158 949.250 0.086 0.008 3.497 0.495 0.197 0.016 11500.0 0.305 32.112 2.240 948.966 0.054 0.009 3.582 0.527 0.214 0.018 12000.0 0.303 31.661 2.321 948.682 0.100 0.010 3.663 0.560 0.232 0.020 12500.0 0.301 31.214 2.401 948.399 0.105 0.011 3.739 0.592 0.250 0.023 13000.0 0.298 30.771 2.480 548.116 0.111 0.012 3.811 0.625 0.268 0.026 13500.0 0.298 30.331 2.557 947.834 0.117 0.014 3.578 0.658 0.286 0.029 14000.0 0.296 29.896 2.634 947.552 0.123 0.015 3.942 0.692 0.304 0.032 14500.0 0.294 29.465 2.710 947.271 0.129 0.016 4.001 0.725 0.323 0.035 16000.0 0.282 29.036 2.785 946.991 0.135 0.017 4.057 0.759 0.341 0.039 15600.0 0.290 28.612 2.859 946.712 0.141 0.019 4.110 0.792 0.359 0.043 16000.0 0.289 28.191 2.932 946.433 0.147 0.020 4.158 0.826 0.378 0.047 16500.0 0.297 27.773 3.004 946.194 0.153 0.022 4.204 0.860 0.396 0.051 17000.0 0.285 27.358 3.075 949.877 0.159 0.023 4.246 0.993 0.415 0.055 17500.0 0.284 26.947 3.146 945.599 0.165 0.025 4.286 0.927 0.433 0.060 18000.0 '0.282 26.538 3.215 545.322 0.172 0.026 4.322 0.961 0.451 0.065 18500.0 0.280 26.133 3.254 945.045 0.178 0.028 4.356 0.995 0.468 0.070 19000.0 0.278 25.731 3.352 944.768 0.184 0.030 4.387 1.028 0.487 0.075 19500.0 0.277 25.332 3.419 944.490 0.190 0.032 4.417 1.062 0.505 0.080 20000.0 0.275 24.936 3.485 944.212 0.197 0.033 4.444 1.095 0.523 0.086 20500.0 0.273 24.544 3.551 943.833 0.203 0.035 4.470 1.128 0.540 0.091 21000.0 0.272 24.155 3.615 943.654 0.210 0.037 4.494 1.161 0.558 0.097 21500.0 0.270 23.768 3.679 943.373 0.216 0.039 4.516 1.194 0.576 0.104 22000.0 0.268 23.386 3.742 943.051 0.223 0.041 4.537 1.226 0.594 0.110 22500.0 0.267 23.006 3.804 942.808 0.228 0.044 4.557 1.259 0.611 0.116 25000.0 0.259 21.157 4.104 941.371 0.263 0.056 4.637 1.417 0.698 0.152 27500.0 0.250 19.391 4.384 539.899 0.298 0.070 4.689 1.570 0.753 0.194 30000.0 0.242 17.707 4.644 938.385 0.334 0.086 4.717 1.717 0.862 0.241 32500.0 0.234 16.106 4.885 936.841 0.371 0.103 4.724 1.857 0.936 0.293 35000.0 0.226 14.598 5.106 535.251 0.407 0.123 4.714 1.989 1.003 0.350 37500.0 0.218 13.153 5.309 933.618 0.444 0.144 4.689 2.115 1.064 0.412 40000.0 0.210 11.801 5.492 931.939 0.480 0.168 4.652 2.232 1.118 0.479 42500.0 0.202 10.533 5.657 930.213 0.516 0.192 4.604 2.340 2.165 0.551 45000.0 0.195 9.350 5.803 928.438 0.551 0.218 4.549 2.441 1.205 0.627 47500.0 0.187 8.251 5.929 926.611 0.585 0.246 4.489 2.532 1.239 0.707 90000.0 0.180 7.237 6.037 924.731 0.618 0.273 4.425 2.614 1.266 0.791 52500.0 0.172 6.307 6.127 922.797 0.650 0.302 4.359 2.687 1.287 0.878 55000.0 0.165 5.461 6.199 920.807 0.680 0.330 4.292 2.751 1.304 0.968 57500.0 0.158 4.697 6.253 918.762 0.708 0.359 4.228 2.807 1.325 1.061 60000.0 0.151 4.013 6.290 516.662 0.735 0.387 4.162 2.854 1.322 1.155 62500.0 0.144 3.406 6.311 914.507 0.759 0.414 4.101 2.894 1.326 1.252 65000.0 0.137 2.872 6.316 512.301 0.781 0.440 4.044 2.926 1.326 1.349 67500.0 0.131 2.407 6.308 510.044 0.801 0.464 3.951 2.951 1.325 1.447 70000.0 0.125 2.006 6.287 907.741 0.819 0.487 3.942 2.970 1.321 1.544 AREVA Inc.
ControlIed Document Nuclear Fuel Design Report ANP-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page C-10 Table C.9 [ ] Exposure-Dependent 80%
Void Isotopics (kgIMTU Initial)
Exposure l4Wd/MTU 0-234 0-235 U-236 U-238 NP-237 PU-238 P0-239 P0-240 P0-241 P0-242 0.0 0.352 43.987 0.000 955.661 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.351 43.869 0.025 955.592 0.000 0.000 0.024 0.000 0.000 0.000 500.0 0.349 43.395 0.122 955.315 0.002 0.000 0.245 0.002 0.000 0.000 1000.0 0.347 42.913 0.242 954.969 0.005 0.000 0.528 0.008 0.001 0.000 1500.0 0.344 42.242 0.359 954.625 0.008 0.000 0.797 0.019 0.002 0.000 2000.0 0.342 41.661 0.474 954.281 0.011 0.000 1.054 0.032 0.004 0.000 2500.0 0.339 41.129 0.987 953.938 0.015 0.000 1.298 0.049 0.007 0.000 3000.0 0.337 40.986 0.698 953.596 0.019 0.001 1.530 0.067 0.012 0.O000 3500.0 0.334 40.051 0.806 953.255 0.023 0.001 1.752 0.088 0.018 0.O000 4000.0 0.332 39.524 0.813 952.916 0.027 0.001 1.963 0.111 0.026 0.001 4500.0 0.329 39.005 1.017 852.576 0.032 0.002 2.165 0.135 0.035 0.001 5000.0 0.327 28.492 1.120 952.238 0.037 0.002 2.398 0.160 0.045 0.001 5500.0 0.325 37.987 1.221 951.901 0.042 0.002 2.541 0.186 0.0956 0.002 6000.0 0.322 37.488 1.320 991.9595 0.047 0.003 2.717 0.214 0.069 0.003 5500.0 0.320 36.986 1.418 951.230 0.052 0.004 2.884 0.242 0.082 0.003 7000.0 0.318 36.510 1.514 950.895 0.058 0.004 3.044 0.271 0.097 0.004 7500.0 0.316 36.030 1.608 950.551 0.064 0.005 3.197 0.301 0.112 0.005 8000.0 0.313 35.556 1.701 950.229 0.070 0.006 3.342 0.332 0.128 0.007 8500.0 0.311 35.087 1.792 949.897 0.076 0.007 3.481 0.363 0.145 0.008 9000.0 0.309 34.623 1.882 949.565 0.082 0.008 3.614 0.395 0.163 0.010 9500.0 0.307 34.165 1.970 945.235 0.089 0.009 3.741 0.428 0.181 0.011 10000.0 0.305 33.712 2.058 948.905 0.095 0.010 3.851 0.460 0.200 0.013 10500.0 0.303 33.264 2.143 848.576 0.102 0.011 3.977 0.484 0.219 0.016 11000.0 0.300 32.821 2.228 948.247 0.108 0.012 4.086 0.527 0.239 0.018 11500.0 0.298 32.382 2.311 947.919 0.115 0.013 4.191 0.561 0.258 0.020 12000.0 0.295 31.948 2.383 947.552 0.122 0.015 4.291 0.586 0.279 0.023 12500.0 0.294 31.519 2.474 947.265 0.129 0.016 4.385 0.631 0.300 0.026 13000.0 0.292 31.094 2.554 946.939 0.136 0.018 4.475 0.556 0.321 0.029 13500.0 0.290 30.673 2.632 946.614 0.143 0.019 4.561 0.701 0.342 0.032 14000.0 0.288 30.256 2.710 946.289 0.150 0.021 4.642 0.735 0.363 0.036 14500.0 0.286 29.843 2.786 945.965 0.157 0.023 4.719 0.772 0.384 0.039 15000.0 0.284 29.434 2.861 945.642 0.164 0.024 4.791 0.808 0.405 0.043 15500.0 0.252 29.030 2.935 945.319 0.172 0.026 4.860 0.844 0.427 0.047 16000.0 0.280 28.628 3.008 944.997 0.179 0.028 4.925 0.880 0.448 0.051 15500.0 0.278 28.231 3.080 944.675 0.186 0.030 4.986 0.916 0.469 0.056 17000.0 0.277 27.535 3.151 944.355 0.194 0.032 5.044 0.953 0.481 0.050 17500.0 0.275 27.446 3.221 944.036 0.201 0.034 5.098 0.989 0.512 0.065 18000.0 0.273 27.058 3.290 943.715 0.208 0.037 5.149 1.025 0.533 0.070 18500.0 0.271 25.674 3.358 943.387 0.216 0.039 5.197 1.062 0.554 0.075 19000.0 0.259 26.294 3.426 943.078 0.223 0.041 5.242 1.098 0.574 0.080 19500.0 0.257 25.916 3.492 942.760 0.231 0.044 5.285 1.135 0.585 0.086 20000.0 0.255 25.542 3.557 942.441 0.238 0.047 5.325 1.171 0.516 0.081 20500.0 0.284 25.171 3.622 942.122 0.246 0.049 5.362 1.207 0.636 0.097 21000.0 0.262 24.803 3.586 941.802 0.253 0.052 5.398 1.243 0.556 0.103 21500.0 0.260 24.439 3.749 941.482 0.261 0.055 5.432 1.279 0.577 0.110 22000.0 0.258 24.077 3.811 941.161 0.268 0.058 5.464 1.315 0.697 0.116 22500.0 0.257 23.719 3.872 940.840 0.276 0.051 5.494 1.350 0.717 0.123 23000.0 0.255 23.365 3.932 940.517 0.284 0.064 5.523 1.385 0.737 0.129 23500.0 0.253 23.013 3.992 940.194 0.291 0.067 5.550 1.421 0.757 0.136 24000.0 0.251 22.664 4.051 939.869 0.299 0.070 5.576 1.456 0.777 0.144 24500.0 0.250 22.319 4.109 939.543 0.307 0.073 5.601 1.490 0.797 0.151 25000.0 0.248 21.978 4.166 939.216 0.315 0.077 5.524 1.525 0.816 0.159 27500.0 0.239 20.316 4.440 937.561 0.354 0.055 5.723 1.694 0.913 0.199 30000.0 0.231 18.736 4.693 935.872 0.393 0.116 5.796 1.857 1.007 0.244 32500.0 0.223 17.233 4.928 934.150 0.433 0.139 5.845 2.013 1.095 0.293 35000.0 0.215 15.809 5.143 932.394 0.473 0.164 5.874 2.163 1.178 0.347 37500.0 0.207 14.462 5.339 930.502 0.513 0.191 5.886 2.305 1.255 0.404 40000.0 0.199 13.191 5.517 928.773 0.553 0.220 5.883 2.440 1.325 0.466 42500.0 0.191 11.995 5.676 926.908 0.591 0.251 5.866 2.568 1.389 0.531 45000.0 0.184 10.873 5.817 925.005 0.629 0.284 5.839 2.687 1.447 0.598 47500.0 0.177 9.823 5.941 923.064 0.666 0.318 5.803 2.798 1.499 0.671 50000.0 0.170 8.845 6.048 921.085 0.702 0.354 5.751 2.901 1.544 0.745 52500.0 0.163 7.937 6.139 919.057 0.736 0.390 5.712 2.986 1.584 0.822 55000.0 0.157 7.098 6.213 917.011 0.768 0.425 5.650 3.082 1.618 0.902 57500.0 0.150 5.325 6.272 914.916 0.799 0.463 5.505 3.151 1.647 0.983 50000.0 0.144 5.616 6.316 912.784 0.827 0.500 5.549 3.231 1.671 1.067 62500.0 0.138 4.969 6.347 910.615 0.854 0.537 5.492 3.294 1.590 1.152 65000.0 0.133 4.381 6.364 908.410 0.879 0.573 5.436 3.349 1.705 1.238 57500.0 0.127 3.850 6.368 906.171 0.902 0.607 5.381 3.398 1.718 1.326 70000.0 0.122 3.373 6.351 903.898 0.922 0.541 5.327 3.440 1.726 1.415 AREVA Inc.
Controlled Document Nuclear FuelUnit Design Report ANP-3294NP Quad Cities 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page C-Il Table C.10 [ ] Exposure-Dependent 0% Void Isotopics (kg/MTU Initial)
Exposure MWd/OOTU U-234 0-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 9U-242 0.0 0.352 43,987 0.000 955.661 0.000 0.000 0,000 0.000 0.000 0.000 100.0 0.352 42.867 0.022 955.611 0,000 0.000 0,018 0.000 0.000 0.000 500.0 0.350 43.390 0.111 985.411 0.002 0.000 0.180 0.001 0.000 0.000 1000.0 0.248 42.800 0.220 955.160 0.002 0.000 0,388 0.006 0.000 0.000 1500.0 0.346 42,218 0.327 954.910 0.005 0.000 0,586 0.014 0,001 0,000 2000.0 0.344 41,645 0.433 954.659 0.008 0.000 0,775 0,025 0.002 0.000 2500.0 0.342 41,078 0.537 954.410 0.010 0.000 0.954 0.038 0.004 0.000 3000.0 0.341 40.518 0.839 954.160 0,013 0.000 1.125 0.053 0.007 0.000 3500.0 0.339 39.964 0.740 953.912 0.015 0.000 1.287 0,070 0.010 0.000 4000.0 0.237 39.417 0.840 953.663 0.018 0.001 1,442 0.088 0.014 0.000 4500.0 0.335 38.876 0.838 953,415 0.021 0,001 1.589 0,108 0.019 0.001 5000.0 0.332 38.340 1.034 953.168 0,024 0.001 1.728 0.130 0.025 0.001 5500.0 0.332 37.810 1.130 952.921 0,028 0.001 1.861 0.152 0.032 0.001 6000 .0 0.330 37.286 1.224 952.675 0.031 0.002 1. 987 0.176 0.040 0.002 6500.0 0.328 36.766 1.317 952.429 0.035 0.002 2.107 0.200 0.048 0.002 7000.0 0.326 36,252 1.408 952,184 0,038 0.002 2.221 0,225 0.057 0.003 7500.0 0.324 35,742 1,499 951.940 0.042 0.003 2.328 0.251 0.067 0.004 8000 .0 0 .323 35.237 1.588 951.695 0.046 0.003 2,431 0.278 0.077 0.004 5500 .0 0.321 34,737 1.676 951.451 0.050 0.003 2.528 0.305 0.088 0.005 5000 .0 0.319 34.241 1,764 951.208 0.054 0.004 2.620 0,3233 0.100 0.007 5500.0 0,318 33.750 1.850 950.964 0.058 0.004 2,708 0.361 0.112 0.008 10000.0 0,316 33.263 1.935 950.721 0.062 0.005 2.790 0.390 0.125 0.009 10500.0 0,314 32.779 2.019 950.479 0.067 0,005 2,869 0,419 0.138 0.011 11000.0 0.313 32.300 2.102 950,236 0.071 0.006 2,942 0.448 0.151 0.013 11500.0 0,311 31.825 2.184 949.994 0.076 0.007 3.012 0.478 0.165 0.014 12000.0 0.309 31.354 2,265 949.752 0.090 0.007 3.078 0.508 0.179 0.016 12500.0 0.308 30,888 2.345 949.511 0,085 0.008 3.139 0.538 0.193 0.019 13000.0 0.306 30.422 2.424 949.270 0.090 0.009 3.197 0.569 0,207 0.021 13500.0 0.304 29.962 2.502 949.029 0.094 0,010 3,251 0. 600 0.222 0.024 14000 .0 0 .302 29.505 2.579 948.789 0.099 0.011 3.302 0. 631 0.227 0.026 14500 .0 0,301 29.051 2.856 948.549 0.104 0.011 3.34 9 0,662 0.252 0.029 15000 .0 0.299 28.601 2,731 948.310 0.109 0.012 3,392 0.693 0.267 0,0322 15500.0 0.2988 28.153 2,806 948.072 0.114 0.013 3.433 0.724 0.282 0,025 16000.0 0.296 27.709 2.880 947.824 0.119 0,014 3.470 0.756 0.296 0.039 16500.0 0.295 27.268 2,953 947.596 0,124 0.015 3.505 0.787 0.311 0.042 17000.0 0.293 26,829 3.026 947.359 0.129 0.016 3.536 0.819 0.326 0,046 17500.0 0.291 26.394 3.098 947.122 0.134 0.018 3.566 0. 850 0.341 0.050 18000 .0 0.290 25.962 3.1688 946.884 0,139 0.019 3.593 0.881 0,356 0.054 18500.0 0.288 25,522 3.239 946.646 0.144 0.020 3.618 0. 913 0.371 0.059 19000.0 0.287 25.106 3.308 946.408 0.149 0.021 3.641 0. 944 0,285 0.063 19500.0 0,285 24,682 3.377 946.168 0.155 0.023 3.662 0. 975 0.400 0.068 20000.0 0.284 24.262 3.445 946.928 0.160 0.024 2.682 1,006 0.415 0.073 20500.0 0 .282 23.845 3.512 945.686 0,165 0,025 2,700 1.037 0.430 0,078 22500.0 0,276 22.210 3,773 944.705 0.197 0.031 3.761 1,159 0.489 0.101 25000.0 0.268 20.239 4.083 943.445 0.216 0.040 3.811 1.307 0.562 0.134 27500.0 0.260 18.353 4.374 942.144 0,246 0.051 3.835 1.451 0.632 0.173 30000.0 0.252 16.551 4.646 940.801 0.277 0,063 3.837 1.589 0,697 0.218 32500.0 0.244 14.826 4.899 939,410 0,309 0.077 3.822 1,722 0.757 0.269 35000.0 0.236 13.210 5.132 937,969 0.341 0.092 3.791 1,847 0.811 0.226 37500.0 0,228 11,677 5.245 936,473 0,372 0.109 3.748 1.964 0.858 0.389 40000.0 0.220 10,238 5.537 934.918 0.406 0.127 3.695 2.074 0.899 0.458 42500.0 0,212 9,899 5.709 933.300 0.439 0,146 3.625 2.175 0.933 0,533 45000.0 0.203 7.661 5.860 931.612 0.470 0.167 3.571 2.266 0.961 0.614 47500.0 0.195 6.528 5.989 929.853 0.501 0.189 3.504 2.348 0.983 0.701 50000.0 0.187 5.502 8.095 928.017 0.531 0.211 3,427 2.421 0.999 0,793 52500.0 0,179 4.584 6.180 926,101 0.560 0.233 3.371 2.4 83 1,010 0.890 55000 .0 0.170 3.775 6.243 924.105 0.587 0.255 3.208 2,536 1.017 0.991 57500.0 0,162 3.072 6.288 922.028 0.612 0.277 3.249 2.579 1,020 1.095 60000.0 0.154 2,471 6.307 919.871 0,635 0.298 2.198 2.612 1.020 1.202 62500.0 0.146 1.965 6,311 917.640 0.686 0.317 3.148 2.640 1.018 1.312 65000 .0 0.138 1.548 6.298 915.339 0.674 0.335 3.106 2.659 1.014 1.422 67500.0 0.130 1.208 6.270 912.976 0.690 0.351 3.069 2. 672 1.009 1,533 70000.0 0.123 0.938 6.229 910.560 0.704 0.366 3.038 2. 682 1.004 1.643 AREVA Inc.
Control~ed Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page C-12 Table C.11 [ J Exposure-Dependent 40%
Void Isotopics (kg/MTU Initial)
Exposure b4Wd/M4T1 U1-234 U1-235 U1-236 U1-238 NP-237 PU1-238 PU1-239 PU1-240 PU1-241 PU1-242 0.0 0.352 43.987 0.000 955.681 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.351 43.867 0.023 955.604 0.000 0.000 0.020 0.000 0.000 0.000 500.0 0.350 43.391 0.115 955.373 0.002 0.000 0.306 0.002 0.000 0.000 1000.0 0.348 42.805 0.228 955.085 0.004 0.000 0.444 0.007 0.000 0.000 1500.0 0.345 42.228 0.340 954.797 0.008 0.000 0.870 0.018 0.001 0.O000 2000.0 0.343 41.859 0.448 984.510 0.009 0.000 0.885 0.028 0.003 0.000 2500.0 0.341 41.098 0.5568 954.223 0.012 0.000 1.090 0.042 0.005 0.000 3000.0 0.339 40.545 0.662 953.938 0.015 0.000 1.285 0.059 0.009 0.000 3500.0 0.337 39.999 0.765 983.652 0.018 0.001 1.470 0.078 0.013 0.000 4000.0 0.335 38.460 0.567 953.368 0.022 0.001 1.646 0.098 0.019 0.000 4500.0 0.333 38.928 0.968 953.084 0.025 0.001 1.814 0.120 0.025 0.001 5000.0 0.331 38.402 1.067 952.802 0.029 0.001 1.974 0.144 0.033 0.001 5500.0 0.329 37.883 1.164 952.520 0.033 0.002 2.125 0.168 0.041 0.002 6000.0 0.327 37.369 1.260 952.239 0.037 0.002 2.270 0.193 0.051 0.002 6500.0 0.325 36.861 1.355 951.958 0.042 0.002 2.407 0.220 0.061 0.003 7000.0 0.323 36.359 1.448 951.678 0.046 0.003 2.537 0.247 0.073 0.003 7500.0 0.321 35.862 1.539 951.399 0.060 0.003 2.661 0.275 0.085 0.004 8000.0 0.319 35.370 1.630 981.121 0.055 0.004 2.779 0.303 0.098 0.005 8500.0 0.317 34.883 1.719 850.843 0.060 0.004 2.891 0.332 0.111 0.007 9000.0 0.315 34.401 1.807 950.565 0.065 0.005 2.587 0.362 0.125 0.008 9500.0 0.313 33.924 1.893 950.288 0.070 0.006 3.098 0.392 0.140 0.009 10000.0 0.312 33.451 1.979 980.012 0:075 0.006 3.194 0.422 0.155 0.011 10500.0 0.310 32.983 2.063 949.736 0.090 0.007 3.284 0.453 0.171 0.013 11000.0 0.308 32.519 2.146 949.461 0.065 0.008 3.370 0.485 0.187 0.018 11500.0 0.306 32.080 2.228 949.186 0.091 0.009 3.451 0.516 0.203 0.017 12000.0 0.304 31.604 2.309 948.912 0.096 0.010 3.528 0.548 0.220 0.019 12500.0 0.302 31.153 2.389 948.638 0.102 0.011 3.601 0.580 0.237 0.022 13000.0 0.301 30.706 2.488 948.385 0.108 0.012 3.869 0.612 0.264 0.025 13500.0 0.298 30.262 2.546 948.092 0.113 0.013 3.733 0.645 0.272 0.028 14000.0 0.297 29.822 2.623 947.820 0.119 0.014 3.793 0.678 0.289 0.031 14500.0 0.295 29.386 2.699 947.549 0.125 0.015 3.849 0.711 0.307" 0.034 15000.0 0.294 28.953 2.774 947.278 0.130 0.016 3.902 0.744 0.324 0.037 15500.0 0.292 28.524 2.848 847.008 0.136 0.018 3.951 0.777 0.342 0.041*
16000.0 0.290 28.098 2.921 948.738 0.142 0.019 3.996 0.810 0.360 0.045 16500.0 0.288 27.675 2.994 946.470 0.148 0.020 4.038 0.843 0.377 0.048 17000.0 0.287 27.255 3.068 946.202 0.154 0.022 4.078 0.876 0.395 0.053 17500.0 0.285 26.839 3.136 945.934 0.160 0.023 4.114 0.910 0.412 0.058 18000.0 0.283 26.425 3.206 945.666 0.166 0.025 4.148 0.543 0.429 0.082 18500.0 0.282 26.014 3.275 945.398 0.172 0.028 4.179 0.976 0.447 0.067 19000.0 0.280 25.607 3.343 945.130 0.178 0.028 4.208 1.009 0.464 0.072 19500.0 0.278 25.203 3.410 944.862 0.184 0.030 4.236 1.042 0.481 0.077 20000.0 0.277 24.802 3.477 944.593 0.190 0.031 4.261 1.075 0.498 0.083 20500.0 0.275 24.404 3.543 944.322 0.196 0.033 4.284 1.107 0.515 0.088 21000.0 0.274 24.009 3.608 944.051 0.202 0.035 4.306 1.140 0.532 0.094 21500.0 0.272 23.617 3.672 943.779 0.209 0.037 4.327 1.172 0.549 0.100 22500.0 0.269 22.844 3.798 943.231 0.221 0.041 4.364 1.236 0.583 0.113 25000.0 0.260 20.988 4.100 941.836 0.254 0.053 4.436 1.392 0.887 0.148 27500.0 0.252 19.175 4.383 940.404 0.288 0.066 4.480 1.542 0.747 0.189 30000.0 0.244 17.465 4.648 938.934 0.323 0.081 4.500 1.687 0.823 0.235 32500.0 0.236 15.838 4.889 937.423 0.359 0.098 4.501 1.825 0.893 0.287 35000.0 0.228 14.295 5.114 935.870 0.394 0.116 4.484 1.956 0.957 0.344 37500.0 0.220 12.836 8.319 934.271 0.430 0.137 4.453 2.079 1.015 0.406 40000.0 0.212 11.463 5.505 932.625 0.466 0.159 4.410 2.194 1.065 0.473 42500.0 0.204 10.177 5.671 930.928 0.501 0.183 4.358 2.301 1.109 0.545 45000.0 0.197 8.978 5.819 929.179 0.535 0.207 4.299 2.399 1.145 0.622 47500.0 0.189 7.867 5.946 927.374 0.568 0.233 4.235 2.488 1.176 0.703 50000.0 0.181 6.845 6.055 925.512 0.601 0.260 4.168 2.568 1.200 0.789 52500.0 0.174 5.912 8.145 523.590 0.832 0.287 4.100 2.638 1.218 0.878 55000.0 0.166 5.088 6.215 921.809 0.861 0.314 4.032 2.700 1.231 0.970 57500.0 0.159 4.311 6.268 919.566 0.688 0.341 3.966 2.752 1.240 1.065 60000.0 0.182 3.638 8.302 917.464 0.714 0.367 3.902 2.796 1.244 1.162 62500.0 0.144 3.047 6.320 915.302 0.737 0.392 3.842 2.832 1.246 1.260 55000.0 0.138 2.534 6.322 913.083 0.759 0.416 3.787 2.861 1.244 1.360 67500.0 0.131 2.092 6.310 910.811 0.776 0.439 3.736 2.883 1.241 1.461 70000.0 0.124 1.716 6.285 908.490 0.794 0.459 3.690 2.899 1.238 1.561 AREVA Inc.
Contrailed Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page C-13 Table C.12 [ ] Exposure-Dependent 80%
Void Isotopics (kg/MTU Initial)
Exposure Mud/MTUO 0-234 U-235 U-236 0-238 NP2-237 PU-238 P0-239 P0-240 PU-241 P0-242 0.0 0.352 43.987 0.000 955.661 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.351 43.866 0.024 955.593 0.000 0.000 0.024 0.000 0.000 0.000 500.0 0.349 43.395 0.122 955.320 0.002 0.000 0.241 0.002 0.000 0.000 1000.0 0.347 42.614 0.241 954.980 0.005 0.000 0.519 0.008 0.000 0.000 1900.0 0.344 42.243 0.357 954.641 0.008 0.000 0.783 0.016 0.002 0.000 2000.0 0.342 41.682 0.472 954.302 0.011 0.000 1.035 0.032 0.004 0.000 2500.0 0.339 41.130 0.584 953.965 0.015 0.000 1.275 0.046 0.007 0.000 3000.0 0.337 40.587 0.694 953.629 0.019 0.001 1.503 0.066 0.012 0.000 3500.0 0.334 40.051 0.602 953.293 0.023 0.001 1.721 0.067 0.016 0.000 4000.0 0.332 39.524 0.909 952.959 0.027 0.001 1.928 0.109 0.025 0.001 4500.0 0.330 39.004 1.012 952.625 0.032 0.002 2.126 0.133 0.034 0.001 5000.0 0.327 36.491 1.114 952.293 0.036 0.002 2.315 0.158 0.044 0.001 5500.0 0.325 37.965 1.215 951.961 0.041 0.002 2.495 0.184 0.055 0.002 6000.0 0.323 37.465 1.314 951.630 0.047 0.003 2.666 0.211 0.067 0.003 6500.0 0.321 36.992 1.411 951.301 0.052 0.004 2.830 0.239 0.060 0.003 7000.0 0.318 36.505 1.506 950.972 0.058 0.004 2.966 0.268 0.084 0.004 7500.0 0.316 36.023 1.600 950.644 0.063 0.005 3.136 0.296 0.109 0.005 8000.0 0.314 35.548 1.693 950.317 0.069 0.006 3.278 0.326 0.125 0.007 6500.0 0.312 35.078 1.784 948.990 0.075 0.006 3.413 0.359 0.141 0.008 9000.0 0.310 34.613 1.873 949.665 0.081 0.007 3.543 0.391 0.159 0.010 8500.0 0.307 34.153 1.962 949.340 0.086 0.008 3.666 0.423 0.177 0.011 10000.0 0.305 33.698 2.049 949.016 0.094 0.009 3.784 0.456 0.195 0.013 10500.0 0.303 33.249 2.134 948.692 0.100 5.011 3.896 0.489 0.214 0.015 11000.0 0.301 32.604 2.219 948.369 0.107 0.012 4.003 0.522 0.233 0.017 11500.0 0.299 32.364 2.302 948.047 0.114 0.013 4.104 0.556 0.253 0.020 12000.0 0.297 31.928 2.384 947.726 0.120 0.014 4.201 0.590 0.273 0.023 12500.0 0.295 31.497 2.465 947.405 0.127 0.016 4.293 0.624 0.293 0.025 13000.0 0.293 31.069 2.544 847.085 0.134 0.017 4.380 0.659 0.313 0.028 13500.0 0.291 30.647 2.623 946.765 0.141 0.019 4.462 0.684 0.334 0.032 14000.0 0.269 30.228 2.700 946.447 0.148 0.020 4.541 0.728 0.355 0.035 14500.0 0.287 29.813 2.776 946.128 0.155 0.022 4.615 0.754 0.376 0.038 15000.0 0.285 29.402 2.851 945.611 0.162 0.024 4.884 0.800 0.397 0.042 15500.0 0.283 298995 2.925 945.485 0.168 0.026 4.750 0.835 0.417 0.046 16000.0 0.281 28.591 2.998 945.179 0.176 0.027 4.913 0.871 0.438 0.050 16500.0 0.279 28.191 3.070 944.864 0.184 0.029 4.871 0.907 0.459 0.055 17000.0 0.278 27.794 3.141 944.549 0.191 0.031 4.926 0.943 0.480 0.059 17500.0 0.276 27.401 3.212 944.235 0.198 0.034 4.978 0.979 0.500 0.064 18000.0 0.274 - 27.011 3.291 943.922 0.205 0.036 5.026 1.015 0.521 0.069 18500.0 0.272 26.625 3.349 943.608 0.213 0.038 5.072 1.051 0.541 0.074 19000.0 0.270 26.241 3.416 943.296 0.220 0.040 5.115 1.087 0.562 0.079 19500.0 0.268 25.861 3.483 942.984 0.227 0.043 5.155 1.123 0.582 0.085 20000.0 0.267 25.484 3.549 942.671 0.235 0.045 5.193 1.159 0.602 0.090 20500.0 0.265 25.110 3.613 942.357 0.242 0.048 5.228 1.195 0.522 0.086 21000.0 0.263 24.740 3.677 942.044 0.250 0.050 5.262 1.230 0.642 0.102 21500.0 0.261 24.373 3.740 941.730 0.257 0.053 5.294 1.266 0.662 0.108 22000.0 0.260 24.008 3.802 941.414 0.264 0.056 5.324 1.301 0.682 0.115 22500.0 0.256 23.648 3.863 941.098 0.272 0.059 5.353 1.336 0.701 0.121 23000.0 0.256 23.290 3.924 940.781 0.280 0.062 5.380 1.371 0.721 0.129 23500.0 0.254 22.936 3.984 940.463 0.287 0.065 5.405 1.406 0.740 0.135 24000.0 0.253 22.584 4.043 940.144 0.295 0.068 5.429 1.440 0.760 0.142 24500.0 0.251 22.236 4.101 939.823 0.302 0.071 5.452 1.474 0.779 0.149 25000.0 0.249 21.892 4.156 939.501 0.310 0.074 5.474 1.509 0.796 0.157 27500.0 0.241 20.217 4.433 937.872 0.349 0.092 5.565 1.675 0.894 0.197 30000.0 0.232 18.622 4.688 936.210 0.388 0.112 5.630 1.836 0.965 0.242 32500.0 0.224 17.106 4.923 934.513 0.426 0.135 5.673 1.990 1.071 0.292 35000.0 0.216 15.669 5.140 932.781 0.467 0.159 5.695 2.137 1.151 0.345 37500.0 0.208 14.308 5.337 931.013 0.507 0.166 5.700 2.277 1.226 0.403 40000.0 0.200 13.026 5.516 929.208 0.546 0.214 5.691 2.410 1.294 0.465 42500.0 0.193 11.619 5.676 927.365 0.584 0.245 5.668 2.535 1.356 0.531 45000.0 0.185 10.687 5.818 825.463 0.622 0.277 5.636 2.652 1.411 0.600 47500.0 0.178 9.629 5.943 923.561 0.658 0.310 5.595 2.760 1.460 0.572 50000.0 0.171 8.644 6.050 921.600 0.694 0.344 5.548 2.860 1.502 0.747 52500.0 0.164 7.730 6.141 919.599 0.727 0.380 5.495 2.952 1.539 0.625 55000.0 0.158 6.986 6.215 917.557 0.760 0.415 5.439 3.035 1.570 0.906 57500.0 0.151 6.111 6.274 915.475 0.780 0.451 5.361 3.111 1.596 0.988 50000.0 0.145 5.402 6.318 913.354 0.818 0.487 5.322 3.176 1.617 1.073 62500.0 0.139 4.756 6.348 911.194 0.645 0.522 5.262 3.237 1.634 1.159 65000.0 0.133 4.172 6.364 908.996 0.859 0.557 5.204 3.289 1.647 1.247 57500.0 0.128 3.645 6.367 906.761 0.892 0.590 5.147 3.334 1.556 1.336 70000.0 0.122 3.174 6.358 904.492 0.812 0.622 5.092 3.372 1.663 1.426 AREVA Inc.
Cont'o led,.Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page C-14 Table C.13 [ ] Exposure-Dependent 0% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU 0-234 0-235 U-236 0-236 NP-237 P0-238 PU-239 P0-240 P0-241 P0-242 0.0 0.352 43.987 0.000 955.661 0.000 0.000 0.000 0.O000 0.000 0.000 100.0 0.352 43.867 0.022 955.613 0.000 0.000 0.017 0.000 0.000 0.000 500.0 0.350 43.389 0.110 955.418 0.002 0.000 0.175 0.001 0.000 0.000 1000.0 0.348 42.799 0.218 955.174 0.003 0.000 0.378 0.006 0.000 0.000 1500.0 0.346 42.217 0.325 954.929 0.005 0.000 0.571 0.014 0.001 0.000 2000.0 0.344 41.642 0.430 954.695 0.007 0.000 0.756 0.024 0.002 0.000 2500.0 0.343 41.074 0.534 954.441 0.010 0.000 0.931 0.036 0.004 0.000 3000.0 0.341 40.513 0.636 954.196 0.012 0.000 1.098 0.051 0.006 0.000 3500.0 0.339 39.958 0.737 953.952 0.015 0.000 1.259 0.068 0.009 0.O000 4000.0 0.337 39.409 0.836 953.707 0.018 0.001 1.412 0.086 0.014 0.000 4500.0 0.330 38.866 0.934 993.463 0.021 0.001 1.558 0.108 0.018 0.001 5000.0 0.334 38.329 1.031 953.218 0.024 0.001 1.697 0.126 0.024 0.001 5500.0 0.332 37.798 1.126 952.974 0.027 0.001 1.829 0.149 0.031 0.001 6000.0 0.330 37.272 1.220 952.729 0.030 0.001 1.956 0.172 0.038 0.002 6500.0 0.328 36.751 1.313 952.485 0.034 0.002 2.076 0.196 0.046 0.002 7000.0 0.327 36.236 1.405 952.241 0.038 0.002 2.190 0.221 0.055 0.003 7500.0 0.325 35.725 1.495 951.996 0.041 0.002 2.299 0.247 0.055 0.003 8000.0 0.323 35.219 1.585 951.752 0.040 0.003 2.402 0.273 0.075 0.004 8000.0 0.321 34.718 1.674 951.509 0.049 0.003 2.001 0.300 0.086 0.009 9000.0 0.320 34.221 1.761 951.265 0.053 0.004 2.594 0.328 0.098 0.006 9500.0 0.318 33.729 1.847 951.021 0.057 0.004 2.682 0.356 0.110 0.008 10000.0 0.316 33.241 1.932 950.778 0.062 0.005 2.766 0.384 0.122 0.009 10500.0 0.314 32.757 2.016 990.535 0.066 0.005 2.845 0.413 0.135 0.010 11000.0 0.313 32.277 2.099 950.292 0.070 0.006 2.920 0.442 0.148 0.012 11900.0 0.311 31.801 2.181 950.050 0.075 0.007 2.991 0.472 0.162 0.014 12000.0 0.309 31.329 2.253 949.808 0.080 0.007 3.058 0.502 0.176 0.015 12500.0 0.308 30.861 2.343 949.566 0.084 0.008 3.120 0.532 0.190 0.018 13000.0 0.306 30.397 2.422 949.324 0.089 0.009 3.179 0.563 0.205 0.021 13500.0 0.309 29.935 2.500 949.083 0.094 0.010 3.234 0.594 0.219 0.023 14000.0 0.303 29.478 2.578 948.843 0.099 0.010 3.285 0.025 0.234 0.026 14500.0 0.301 29.024 2.654 948.603 0.102 0.012 3.333 0.556 0.249 0.029 15000.0 0.300 28.573 2.730 948.363 0.108 0.012 3.378 0.687 0.264 0.032 15000.0 0.298 28.126 2.805 948.124 0.113 0.013 3.419 0.718 0.279 0.035 16000.0 0.295 27.681 2.878 947.886 0.118 0.014 3.457 0.750 0.294 0.038 16500.0 0.295 27.239 2.952 947.547 0.123 0.015 3.492 0.781 0.308 0.042 17000.0 0.293 26.801 3.025 947.409 0.128 0.016 3.525 0.812 0.323 0.046 17500.0 0.292 26.365 3.096 947.172 0.133 0.017 3.554 0.844 0.338 0.050 18000.0 0.250 25.933 3.167 946.934 0.135 0.019 3.582 0.875 0.353 0.054 18500.0 0.289 25.503 3.237 946.696 0.144 0.020 3.608 0.907 0.368 0.058 19000.0 0.287 25.076 3.307 946.457 0.149 0.021 3.631 0.938 0.383 0.062 19500.0 0.285 24.653 3.376 946.217 0.154 0.022 3.653 0.959 0.397 0.067 20000.0 0.284 24.233 3.444 945.976 0.159 0.024 3.673 1.000 0.412 0.072 20500.0 0.282 23.815 3.511 945.734 0.155 0.028 3.592 1.031 0.427 0.077 21000.0 0.281 23.401 3.577 945.491 0.170 0.027 3.709 1.062 0.442 0.083 22500.0 0.276 22.179 3.772 944.753 0.187 0.031 3.753 1.154 0.486 0.100 25000.0 0.268 20.208 4.082 943.492 0.215 0.040 3.804 1.303 0.559 0.133 27500.0 0.260 18.320 4.373 942.191 0.245 0.051 2.829 1.447 0.629 0.172 30000.0 0.252 16.518 4.645 840.846 0.275 0.063 3.833 1.585 0.695 0.217 32500.0 0.244 14.803 4.898 939.455 0.308 0.075 3.817 1.718 0.755 0.257 35000.0 0.236 13.178 5.131 938.012 0.340 0.092 3.787 1.843 0.809 0.324 37500.0 0.228 11.645 5.344 936.515 0.373 0.108 3.744 1.562 0.856 0.388 40000.0 0.220 10.208 5.536 934.959 0.406 0.127 3.692 2.071 0.897 0.457 42500.0 0.212 8.870 5.708 933.338 0.438 0.146 3.632 2.172 0.932 0.532 45000.0 0.203 7.634 5.858 931.649 0.470 0.167 3.558 2.264 0.960 0.613 47500.0 0.195 6.502 5.986 929.887 0.501 0.188 3.501 2.347 0.982 0.700 50000.0 0.187 5.478 6.092 928.049 0.531 0.211 3.434 2.419 0.998 0.792 52500.0 0.178 4.563 6.177 926.132 0.560 0.233 3.369 2.482 1.009 0.888 55000.0 0.170 3.756 6.239 924.133 0.587 0.255 3.206 2.534 1.016 0.990 57500.0 0.162 3.055 6.281 922.053 0.612 0.277 3.248 2.578 1.019 1.095 50000.0 0.154 2.456 6.303 919.895 0.535 0.297 3.194 2.612 1.018 1.202 62500.0 0.146 1.953 6.306 917.661 0.6555 0.317 3.146 2.639 1.017 1.312 65000.0 0.138 1.537 6.292 915.358 0.574 0.335 3.105 2.659 1.013 1.422 67500.0 0.130 1.200 6.264 912.994 0.690 0.351 3.068 2.672 1.009 1.533 70000.0 0.123 0.929 6.223 910.575 0.704 0.365 3.037 2.681 1.004 1.643 AREVA Inc.
Controlled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page C-15 Table C.14 [ J Exposure-Dependent 40% Void Isotopics (kgIMTU Initial)
ExcposurG Mild/bOTU 0-234 0-235 0-236 U-236 NP-237 P0-238 PU-239 PU-240 P0-241 P0-242 0.0 0.352 43.987 0.000 955.661 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.351 43.967 0.023 955.605 0.000 0.000 0.020 0.000 0.000 0.000 500.0 0.350 43.391 0.114 955.381 0.002 0.000 0.200 0.002 0.000 0.000 1000.0 0.348 42.804 0.227 955.100 0.004 0.000 0.432 0.007 0.000 0.O000 1500.0 0.346 42.226 0.337 954.819 0.006 0.000 0.653 0.015 0.001 0.000 2000.0 0.343 41.6555 0.446 954.539 0.009 0.000 0.863 0.027 0.003 0.000 2500.0 0.341 41.094 0.553 954.259 0.012 0.000 1.054 0.041 0.005 0.000 3000.0 0.339 40.540 0.658 953.978 0.015 0.000 1.255 0.059 0.008 0.000 3500.0 0.337 39.992 0.762 953.699 0.018 0.001 1.438 0.076 0.012 0.000 4000.0 0.335 39.452 0.664 953.418 0.021 0.001 1.612 0.096 0.018 0.000 4500.0 0.333 38.818 0.964 853.139 0.025 0.001 1.778 0.117 0.024 0.001 5000.0 0.331 38.391 1.063 952.859 0.028 0.001 1.937 0.140 0.031 0.001 5500.0 0.329 37.570 1.160 952.580 0.032 0.002 2.068 0.164 0.040 0.001 6000.0 0.327 37.355 1.256 952.301 0.036 0.002 2.232 0.159 0.049 0.002 6500.0 0.325 36.845 1.350 952.022 0.041 0.002 2.370 0.215 0.059 0.003 7000.0 0.323 36.341 1.444 951.743 0.045 0.003 2.501 0.242 0.070 0.003 7500.0 0.321 35.843 1.536 951.465 0.049 0.003 2.625 0.270 0.082 0.004 8000.0 0.320 35.350 1.626 951.157 0.054 0.004 2.744 0.298 0.095 0.005 9500.0 0.318 34.862 1.715 550.910 0.059 0.004 2.557 0.327 0.108 0.006 9000.0 0.316 34.379 1.803 950.632 0.064 0.005 2.965 0.356 0.122 0.009 9500.0 0.314 33.901 1.890 950.355 0.069 0.006 3.057 0.386 0.137 0.009 10000.0 0.312 33.427 1.976 950.079 0.074 0.006 3.164 0.416 0.152 0.011 10500.0 0.310 32.958 2.060 949.803 0.079 0.007 3.255 0.447 0.168 0.013 11000.0 0.308 32.493 2.143 949.527 0.085 0.008 3.342 0.479 0.184 0.015 11500.0 0.305 32.032 2.226 949.252 0.090 0.009 3.425 0.510 0.200 0.017 12000.0 0.305 31.577 2.307 949.977 0.095 0.010 3.503 0.542 0.217 0.019 12500.0 0.303 31.125 2.387 948.703 0.101 0.011 3.576 0.574 0.234 0.021 13000.0 0.301 30.677 2.466 948.429 0.107 0.012 3.645 0.606 0.251 0.024 13500.0 0.299 30.233 2.544 948.157 0.112 0.013 3.710 0.638 0.269 0.027 14000.0 0.297 29.792 2.621 947.884 0.118 0.014 3.771 0.671 0.286 0.030 14500.0 0.296 29.355 2.697 947.612 0.124 0.015 3.828 0.704 0.303 0.033 15000.0 0.294 29.922 2.772 947.341 0.130 0.016 3.882 0.737 0.321 0.037 15500.0 0.292 28.492 2.946 947.071 0.135 0.017 3.932 0.770 0.338 0.040 16000.0 0.291 28.066 2.920 946.801 0.141 0.019 3.979 0.803 0.356 0.044 16500.0 0.289 27.642 2.992 946.532 0.147 0.020 4.021 0.836 0.374 0.048 17000.0 0.297 27.222 3.064 946.263 0.153 0.022 4.061 0.970 0.391 0.052 17500.0 0.285 26.805 3.134 945.995 0.159 0.023 4.098 0.903 0.408 0.057 19000.0 0.284 26.391 3.204 945.727 0.165 0.025 4.133 0.936 0.426 0.061 19500.0 0.282 25.981 3.273 945.459 0.171 0.026 4.165 0.969 0.443 0.066 19000.0 0.290 25.673 3.342 945.190 0.177 0.028 4.195 1.002 0.460 0.071 19500.0 0.279 25.168 3.408 944.921 0.183 0.029 4.222 1.035 0.477 0.076 20000.0 0.277 24.767 3.476 944.652 0.199 0.031 4.249 1.069 0.494 0.092 20500.0 0.275 24.369 3.542 944.382 0.195 0.033 4.272 1.101 0.512 0.097 21000.0 0.274 23.974 3.607 944.110 0.202 0.035 4.294 1.133 0.529 0.093 21500.0 0.272 23.582 3.571 843.938 0.209 0.037 4.315 1.166 0.546 0.099 22500.0 0.269 22.808 3.797 943.289 0.221 0.041 4.353 1.230 0.579 0.112 25000.0 0.261 20.932 4.099 941.893 0.254 0.052 4.426 1.396 0.663 0.147 27500.0 0.253 19.138 4.392 940.461 0.268 0.065 4.471 1.537 0.744 0.187 30000.0 0.244 17.427 4.645 939.989 0.323 0.081 4.493 1.692 0.920 0.234 32500.0 0.236 15.900 4.988 937.478 0.368 0.097 4.484 1.920 0.990 0.285 35000.0 0.229 14.257 5.112 935.923 0.394 0.116 4.479 1.952 0.955 0.342 37500.0 0.220 12.799 5.317 934.324 0.430 0.137 4.447 2.075 1.012 0.404 40000.0 0.212 11.427 5.503 932.676 0.465 0.159 4.405 2.191 1.063 0.472 42500.0 0.204 10.142 5.669 930.977 0.500 0.182 4.353 2.298 1.106 0.544 45000.0 0.197 9.944 5.816 929.226 0.535 0.207 4.294 2.396 1.143 0.621 47500.0 0.199 7.935 5.944 827.419 0.568 0.233 4.231 2.496 1.174 0.702 50000.0 0.191 6.815 6.052 925.555 0.600 0.260 4.164 2.566 1.198 0.797 52500.0 0.174 5.884 6.141 923.632 0.631 0.287 4.096 2.636 1.216 0.876 55000.0 0.166 5.042 6.211 921.648 0.661 0.314 4.028 2.698 1.230 0.969 57500.0 0.159 4.297 6.263 919.603 0.698 0.341 3.962 2.750 1.238 1.064 60000.0 0.152 3.617 6.297 917.498 0.714 0.367 3.899 2.795 1.243 1.161 62500.0 0.144 3.028 6.315 915.334 0.737 0.392 3.839 2.931 1.244 1.260 65000.0 0.139 2.516 6.317 913.113 0.759 0.416 3.784 2.859 1.243 1.360 67500.0 0.131 2.077 6.304 910.939 0.777 0.438 3.733 2.881 1.240 1.460 70000.0 0.124 1.703 6.279 908.515 0.794 0.459 3.698 2.897 1.235 1.561 AREVA Inc.
Controlled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page C-16 Table C.15 [ J Exposure-Dependent 80% Void Isotopics (kg/MTU Initial)
Exposure t4Wd/MTU0 U-234 U-235 0-236 U-238 NP-237 P0-238 2U-239 2U-240 2U-241 20-242 0.0 0.352 43.987 0.000 955.661 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.351 43.868 0.024 955.595 0.000 0.000 0.023 0.000 0.000 0.000 500.0 0.349 43.395 0.121 955.329 0.002 0.000 0.234 0.002 0.000 0.000 1000.0 0.347 42.813 0.239 954.997 0.005 0.000 0.506 0.008 0.000 0.000 1500.0 0.344 42.242 0.355 554.666 0.008 0.000 0.764 0.018 0.002 0.000 2000.0 0.342 41.680 0.468 854.335 0.011 0.000 1.010 0.031 0.004 0.000 2500.0 0.340 41.126 0.580 854.004 0.014 0.000 1.245 0.047 0.007 0.000 3000.0 0.337 40.581 0.690 553.674 0.018 0.001 1.470 0.065 0.011 0.000 3500.0 0.335 40.045 0.797 953.344 0.022 0.001 1.684 0.085 0.017 0.000 4000.0 0.332 39.516 0.903 953.015 0.026 0.001 1.889 0.107 0.024 0.001 4500.0 0.330 38.994 1.007 952.686 0.031 0.001 2.085 0.130 0.032 0.001 5000.0 0.328 38.478 1.108 852.357 0.036 0.002 2.272 0.155 0.042 0.001 5500.0 0.326 37.572 1.210 952.029 0.041 0.002 2.451 0.180 0.053 0.002 6000.0 0.323 37.470 1.308 951.701 0.046 0.003 2.822 0.207 0.064 0.002 6500.0 0.321 36.976 1.406 951.374 0.051 0.003 2.756 0.235 0.077 0.003 7000.0 0.319 36.487 1.501 951.047 0.057 0.004 2.942 0.264 0.091 0.004 7500.0 0.317 36.004 1.555 850.720 0.062 0.005 3.081 0.293 0.106 0.005 8000.0 0.314 35.527 1.688 850.394 0.068 0.005 3.234 0.323 0.122 0.006 8500.0 0.312 35.055 1.779 950.065 0.074 0.006 3.371 0.354 0.138 0.008 9000.0 0.310 34.589 1.869 948.744 0.080 0.007 3.501 0.385 0.155 0.009 9500.0 0.308 34.128 1.957 949.419 0.087 0.005 3.626 0.417 0.173 0.011 10000.0 0.306 33.673 2.045 949.095 0.093 0.009 3.744 0.450 0.191 0.013 10500.0 0.304 33.222 2.130 948.772 0.099 0.010 3.857 0.482 0.210 0.015 11000.0 0.302 32.776 2.215 948.449 0.106 0.011 3.965 0.516 0.229 0.017 11500.0 0.289 32.335 2.298 948.127 0.112 0.013 4.068 0.548 0.249 0.019 12000.0 0.297 31.895 2.380 947.806 0.119 0.014 4.166 0.583 0.268 0.022 12500.0 0.295 31.466 2.461 947.485 0.126 0.015 4.259 0.617 0.289 0.025 13000.0 0.253 31.038 2.541 947.154 0.133 0.017 4.347 0.652 0.309 0.028 13500.0 0.291 30.614 2.620 946.844 0.140 0.018 4.430 0.687 0.330 0.031 14000.0 0.289 30.195 2.697 946.825 0.147 0.020 4.510 0.722 0.350 0.034 14500.0 0.287 29.779 2.773 846.207 0.154 0.022 4.995 0.757 0.371 0.038 15000.0 0.286 29.368 2.848 545.888 0.161 0.023 4.658 0.783 0.352 0.042 15500.0 0.254 28.860 2.923 845.572 0.158 0.025 4.723 0.828 0.413 0.045 16000.0 0.282 28.556 2.586 945.256 0.175 0.027 4.786 0.864 0.434 0.050 16500.0 0.280 28.155 3.068 944.941 0.183 0.029 4.845 0.900 0.455 0.054 17000.0 0.278 27.758 3.139 944.626 0.190 0.031 4.501 0.936 0.475 0.058 17500.0 0.276 27.364 3.209 944.312 0.187 0.033 4.953 0.972 0.496 0.063 18000.0 0.274 28.574 3.278 943.858 0.204 0.035 5.002 1.008 0.516 0.068 18500.0 0.272 26.587 3.347 943.685 0.212 0.038 5.049 1.044 0.537 0.073 19000.0 0.271 26.203 3.414 943.372 0.219 0.040 5.092 1.080 0.557 0.078 19500.0 0.268 25.622 3.481 843.059 0.226 0.042 5.133 1.116 0.577 0.084 20000.0 0.267 25.446 3.546 942.746 0.234 0.045 5.172 1.152 0.598 0.089 20500.0 0.265 25.071 3.611 842.432 0.241 0.047 5.208 1.187 0.618 0.095 21000.0 0.263 24.700 3.675 842.118 0.248 0.050 5.242 1.223 0.638 0.101 21500.0 0.262 24.332 3.738 941.804 0.256 0.053 5.274 1.258 0.657 0.107 22000.0 0.260 23.968 3.800 941.488 0.264 0.056 5.305 1.294 0.677 0.114 22500.0 0.258 23.607 3.862 841.172 0.271 0.058 5.334 1.329 0.697 0.120 23000.0 0.256 23.249 3.922 940.855 0.279 0.061 5.361 1.364 0.716 0.127 23500.0 0.255 22.894 3.982 940.536 0.286 0.064 5.387 1.399 0.736 0.134 24000.0 0.253 22.543 4.041 940.217 0.294 0.067 5.412 1.433 0.755 0.141 24500.0 0.251 22.195 4.099 939.896 0.302 0.071 5.435 1.468 0.775 0.148 25000.0 0.249 21.650 4.157 938.574 0.308 0.074 5.457 1.502 0.754 0.156 27500.0 0.241 20.174 4.431 937.944 0.348 0.092 5.550 1.669 0.889 0.186 30000.0 0.233 18.578 4.687 936.280 0.387 0.112 5.617 1.829 0.981 0.241 32500.0 0.224 17.063 4.922 934.582 0.427 0.134 5.660 1.584 1.067 0.290 35000.0 0.216 15.625 5.138 932.849 0.467 0.159 5.684 2.132 1.148 0.344 37500.0 0.208 14.266 5.335 931.080 0.506 0.185 5.689 2.272 1.222 0.402 40000.0 0.200 12.983 5.514 928.273 0.545 0.214 5.680 2.405 1.290 0.464 42500.0 0.193 11.777 5.674 927.428 0.584 0.244 5.659 2.530 1.352 0.529 45000.0 0.185 10.646 5.816 925.545 0.621 0.276 5.627 2.648 1.407 0.5988 47500.0 0.178 9.589 5.940 923.622 0.658 0.309 5.586 2.756 1.456 0.670 50000.0 0.171 8.605 6.047 921.658 0.693 0.344 5.539 2.857 1.498 0.746 52500.0 0.164 7.693 6.137 919.655 0.727 0.379 5.487 2.949 1.536 0.824 55000.0 0.158 6.851 6.211 917.611 0.759 0.415 5.431 3.033 1.567 0.904 57500.0 0.151 6.078 6.270 915.528 0.790 0.451 5.373 3.108 1.553 0.887 60000.0 0.145 5.371 6.313 913.404 0.818 0.486 5.314 3.175 1.615 1.072 62500.0 0.139 4.727 6.342 911.242 0.845 0.522 5.255 3.235 1.632 1.158 65000.0 0.133 4.145 6.358 909.042 0.869 0.556 5.197 3.287 1.645 1.246 67500.0 0.128 3.621 6.360 906.806 0.892 0.590 5.141 3.332 1.654 1.335 70000.0 0.122 3.152 6.351 904.533 0.912 0.622 5.086 3.370 1.660 1.425 AREVA Inc.
Cont o~docL 6 ment Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page C-17 Table C.16 [ ] Exposure-Dependent 0% Void Isotopics (kg/MTU Initial)
Exposure MWd/14T0 U-234 0-235 U-236 U-238 NP-237 P0-238 PU-239 8U-240 PU-24 1 PU-242 0.0 0.352 43.987 0.000 955.661 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0 .352 43.867 0.022 955.613 0.000 0.000 0.017 0.000 0.000 0.000 500.0 0 .350 43.389 0.110 955.423 0.001 0.000 0.171 0.001 0.000 0.000 1000.0 0.348 42.798 0.218 955.186 0.003 0.000 0.368 0.006 0.000 0.000 1500.0 0 .346 42.215 0.324 554.950 0.005 0.000 0.555 0.013 0.001 0.000 2000.0 0.345 41.639 0.429 954.714 0.007 0.000 0.733 0.024 0.002 0.000 2500.0 0.343 41.069 0.532 954.480 0.009 0.000 0.901 0.036 0.004 0.000 3000.0 0.341 40.506 0.534 954.248 0.012 0.000 1.060 0.050 0.006 0.000 3500.0 0.339 39.949 0.734 954.016 0.014 0.000 1.211 0.067 0.009 0.000 4000.0 0.338 39.398 0.833 953.786 0.017 0.001 1.354 0.084 0.013 0.000 4500.0 0.336 38.852 0.930 953.557 0.019 0.001 1.489 0.103 0.017 0.000 5000 .0 0.334 38.311 1.026 953.330 0.022 0.001 1.616 0.124 0.022 0.001 5500.0 0.333 37.775 1.121 953.104 0.025 0.001 1.737 0.145 0.028 0.001 6000.0 0 .331 37.244 1.214 952.880 0.029 0.001 1.851 0.168 0.035 0.001 6500.0 0 .328 36.717 1.307 952.657 0.031 0.002 1 .958 0.191 0.042 0.002 7000.0 0 .328 35.194 1.398 952.436 0.034 0.002 2.060 0.215 0.050 0.002 7500.0 0 .326 35.676 1.488 952.216 0.038 0.002 2.156 0.239 0.058 0.003 8000.0 0 .324 35.161 1.577 951.997 0.041 0.002 2.247 0.264 0.067 0.004 8500.0 0.323 34.651 1.665 951.778 0.044 0.003 2.333 0.290 0.076 0.004 9000.0 0.321 34.144 1.752 951.559 0.048 0.003 2.415 0.316 0.086 0.005 5500.0 0.320 33.641 1.838 951.341 0.051 0.004 2.493 0.342 0.086 0.006 10000.0 0.318 33.142 1.923 951.122 0.055 0.004 2.567 0.369 0.107 0.008 10500.0 0.317 32.647 2.007 950.902 0.059 0.004 2. 639 0.397 0.118 0.009 11000.0 0.315 32.156 2.091 950.682 0.063 0.005 2.705 0.424 0.129 0.010 11500.0 0.313 31.668 2.173 950.460 0.067 0.006 2.770 0.452 0.141 0. 012 12000.0 0.312 31.184 2.255 950.238 0.071 0.006 2.832 0. 480 0.154 0.013 12500.0 0.310 30.704 2.336 950.015 0.075 6.007 3.891 0.509 0.166 0.015 15000.0 0.302 28.360 2.729 948.880 0.099 0.010 3.149 0. 654 0.234 0. 027 17500 .0 0.294 26.106 3.099 947.715 0.122 0.015 3.351 0.803 0.308 0.043 20000.0 0.286 23.942 3.450 946.517 0.149 0.021 3.504 0. 953 0.384 0.064 22500.0 0.278 21.867 3.782 945.283 0.177 0.028 3.616 1.103 0.459 0.080 25000.0 0.270 19.880 4.093 944.012 0.207 0.037 3. 692 1.251 0.533 0. 122 27500.0 0.262 17.982 4.385 942.699 0.237 0.047 3.737 1.396 0.604 0.160 30000.0 0 .254 16.174 4.658 941.342 0.269 0.059 3.757 1.537 0.670 0.204 32500.0 0 .246 14.457 4.910 939.937 0.301 0.073 3.754 1.672 0.732 0.255 35000.0 0.239 12.834 5.141 938.480 0.334 0.068 3.734 1.802 0.787 0.311 37500.0 0 .229 11.307 5.352 936.868 0.368 0.105 3. 699 1.924 0.636 0.374 40000.0 0 .221 9.879 5.542 935.391 0.401 0.123 3. 652 2.037 0.878 0.443 42500.0 0 .213 8.554 5.710 933.751 0.434 0.143 3.597 2.143 0.813 0.518 45000.0 0.204 7.334 5.857 932.040 0.467 0.164 3.537 2.238 0.943 0.600 47500.0 0.196 6.222 5.881 930.255 0.498 0.186 3.473 2.324 0.9566 0. 687 50000. 0 0.187 5.219 6.093 928.391 0.528 0.208 3.409 2.400 0.983 0.780 52500.0 0.178 4.328 6.162 926.447 0.557 0.231 3.345 2.465 0.986 0.877 55000.0 0.170 3.546 6.220 924.422 0.585 0.253 3.285 2.520 1.004 0. 979 57500.0 0. 162 2.872 6.257 922.315 0.610 0.275 3.228 2.566 1.008 1.085 60000.0 0. 153 2.299 6.273 920.129 0.633 0.296 3.178 2. 602 1.009 1.193 62500.0 0.145 1.820 6.272 917.870 0.653 0.315 3.132 2. 630 1.009 1.304 55000.0 0.137 1.428 6.254 915.543 0.672 0.333 3.093 2. 651 1.006 1.415 67500.0 0.130 1.110 6.222 913.157 0.687 0.350 3.058 2. 666 1.002 1.526 70000.0 0.122 0.868 6.178 910.720 0.701 0.364 3.030 2. 676 0.998 1. 636 AREVA Inc.
Controlied Documernt Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page C-l8 Table C.17 [ ] Exposure-Dependent 40%1 Void Isotopics (kg/MTU Initial)
Exposure M.Wd/MTU0 0-234 0-235 U-236 0-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.0 0.352 43.9887 0.000 955.661 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.251 43.867 0.023 855.607 0.000 0.000 0.020 0.000 0.000 0.000 500.0 0.350 43.391 0.114 955.388 0.002 0.000 0.195 0.001 0.000 0.000 1000.0 0.346 42.803 0.226 955.117 0.004 0.000 0.419 0.007 0.000 0.000 1000.0 0.346 42.224 0.336 954.847 0.006 0.000 0.631 0.015 0.001 0.000 2000.0 0.344 41.652 0.444 954.576 0.008 0.000 0.832 0.027 0.002 0.000 2500.0 0.342 41.088 0.050 904.211 0.011 0.000 1.023 0.041 0.005 0.000 3000.0 0.340 40.532 0.655 554.045 0.014 0.000 1.203 0.057 0.008 0.000 3500.0 0.238 39.063 0.757 953.781 0.017 0.001 1.374 0.075 0.012 0.000 4000.0 0.336 39.439 0.658 953.518 0.020 0.001 1.536 0.094 0.017 0.000 4500.0 0.334 38.902 0.958 953.257 0.023 0.001 1.689 0.116 0.022 0.001 5000.0 0.332 38.371 1.056 953.998 0.027 0.001 1.833 0.128 0.029 0.001 5500.0 0.330 37.845 1.152 952.741 0.030 0.001 1.970 0.161 0.037 0.001 6000.0 0.328 37.324 1.247 952.485 0.034 0.002 2.100 0.185 0.045 0.002 6500.0 0.327 36.809 1.341 552.231 0.037 0.002 2.222 0.211 0.054 0.002 7000.0 0.325 36.298 1.433 951.979 0.041 0.002 2.337 0.236 0.064 0.003 7500.0 0.323 35.791 1.524 961.726 0.045 0.003 2.447 0.263 0.074 0.004 6000.0 0.321 35.289 1.614 951.476 0.049 0.003 2.550 0.250 0.085 0.005 5500.0 0.319 34.792 1.703 951.226 0.053 0.004 2.649 0.318 0.086 0.006 9000.0 0.316 34.298 1.790 950.980 0.056 0.004 2.742 0.346 0.106 0.007 9500.0 0.316 33.809 1.877 950.731 0.062 0.005 2.831 0.374 0.121 0.006 10000.0 0.314 33.324 1.962 950.463 0.066 0.005 2.916 0.403 0.134 0.009 10500.0 0.312 32.643 2.047 950.234 0.071 0.006 2.897 0.432 0.147 0.011 11000.0 0.311 32.366 2.130 949.984 0.076 0.007 3.075 0.461 0.161 0.012 11500.0 0.309 31.893 2.213 949.733 0.080 0.007 3.149 0.491 0.175 0.014 12000.0 0.307 31.424 2.294 949.482 0.065 0.008 3.220 0.521 0.190 0.016 12500.0 0.306 30.959 2.375 949.229 0.090 0.009 3.289 0.551 0.205 0.019 13000.0 0.304 30.498 2.455 948.976 0.096 0.010 3.354 0.561 0.221 0.021 15000.0 0.297 28.694 2.764 947.951 0.117 0.014 3.589 0.705 0.285 0.032 17500.0 0.289 26.525 3.132 946.642 0.146 0.020 3.828 0.861 0.371 0.050 30000.0 0.280 24.448 3.476 945.301 0.177 0.027 4.016 1.016 0.456 0.073 32500.0 0.272 22.463 3.803 943.926 0.209 0.037 4.159 1.174 0.545 0.102 35000.0 0.263 20.567 4.108 942.519 0.243 0.046 4.263 1.326 0.631 0.136 37500.0 0.255 18.759 4.391 941.074 0.278 0.061 4.334 1.479 0.712 0.175 30000.0 0.247 17.040 4.655 939.589 0.314 0.076 4.377 1.625 0.789 0.221 32500.0 0.236 15.409 4.898 936.062 0.350 0.092 4.395 1.766 0.860 0.272 35000.0 0.230 13.666 5.121 936.491 0.367 0.111 4.392 1.900 0.925 0.326 37500.0 0.222 12.413 5.324 934.874 0.423 0.132 4.373 2.028 0.983 0.390 40000.0 0.214 11.046 5.507 933.207 0.459 0.154 4.339 2.147 1.035 0.457 42500.0 0.206 9.773 5.670 931.469 0.495 0.178 4.294 2.258 1.080 0.529 45000.0 0.196 8.590 5.814 929.715 0.530 0.203 4.241 2.360 1.116 0.607 47500.0 0.190 7.498 5.937 927.866 0.564 0.229 4.183 2.453 1.150 0.688 50000.0 0.192 6.497 6.041 525.997 0.596 0.256 4.120 2.537 1.175 0.774 52600.0 0.174 5.568 6.125 924.048 0.627 0.263 4.055 2.611 1.195 0.863 55000.0 0.166 4.769 6.191 922.036 0.657 0.310 3.991 2.675 1.210 0.958 57500.0 0.169 4.039 6.236 919.966 0.664 0.237 3.926 2.730 1.220 1.052 60000.0 0.152 3.393 6.267 917.834 0.710 0.364 3.868 2.777 1.226 1.150 52500.0 0.144 2.830 6.279 915.643 0.733 0.389 3.811 2.815 1.229 1.249 85000.0 0.137 2.343 6.276 913.396 0.755 0.413 3.759 2.845 1.229 1.350 57500.0 0.131 1.926 6.259 911.096 0.773 0.435 3.711 2.669 1.227 1.451 70000.0 0.124 1.574 6.229 908.749 0.790 0.456 3.668 2.866 1.223 1.552 AREVA Inc.
usonv eD ocdrnert Nuclear FuelUnit Design Report ANP-3294NP Quad Cities 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page C-19 Table C.18 [ ] Exposure-Dependent 80% Void Isotopics (kg/MTU Initial)
Exposure MWd/k4TU 0-234 U-235 0-236 0-238 69-237 P0-238 PU-239 PU-240 PU-24 1 P0,-242 0.0 0.352 43.987 0.000 955.661 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.351 43.868 0.024 955.597 0.000 0.000 0.023 0 .000 0.000 0.000 500.0 0.349 43.394 0.120 955.340 0.002 0.000 0.227 0.002 0.000 0.000 1000.0 0.347 42.812 0.237 955.021 0.005 0.000 0.497 0.008 0.000 0.000 1500.0 0.345 42.239 0.352 954.704 0.007 0.000 0.734 0.018 0.002 0.000 2000.0 0.342 41.676 0.465 954.388 0.010 0.000 0. 968 0.031 0.004 0.000 2500.0 0.340 41.121 0.576 954.074 0.014 0.000 1 .189 0.046 0.007 0.000 3000.0 0.338 4 0.574 0.684 953.762 0.017 0.001 1.399 0.064 0.011 0.000 3500.0 0.335 40.035 0.791 953.451 0.021 0.001 1.598 0.084 0.016 0.000 4000.0 0.333 39.503 0.895 953.143 0.025 0.001 1 .787 0.106 0.023 0.001 4500.0 0.331 38.978 0.998 952.836 0.029 0.001 1.967 0 .129 0.030 0.001 5000.0 0.329 38.459 1.099 952.531 0.033 0.002 2.137 0 .153 0.039 0.001 5500.0 0.327 37.947 1.198 952.228 0.038 0.002 2.298 0.179 0.049 0.002 6000 .0 0.324 37.441 1.286 951.926 0.042 0.003 2.451 0.205 0.060 0.002 6500.0 0.322 36.940 1.392 951.627 0.047 0.003 2.596 0.232 0.071 0.003 7000.0 0.320 36.445 1.486 951.329 0.052 0.004 2.734 0.260 0.084 0.004 7500.0 0.318 35.954 1.579 951.033 0.057 5.004 2.865 0.2899 0.087 0.005 8000.0 0.316 35.469 1.671 950.738 0.062 0.005 2.989 0.318 0.110 0.006 9500.0 0.314 34.988 1.761 950.444 0.068 0.006 3.108 0.348 0.125 0.007 9000.0 0.312 34 .512 1.950 950.151 0.073 0.006 3.221 0 .378 0.140 0.008 9500.0 0.310 34.041 1.938 949.859 0.079 0.007 3.329 0.409 0.155 0.010 10000.0 0.308 33.574 2.025 949.566 0.084 0.008 3.432 0 .440 0.171 0.011 10600.0 0.306 33.112 2.110 949.274 0.090 0.009 3.531 0.471 0.187 0.013 11000.0 0.304 32.653 2.194 948.981 0.096 0.010 3. 625 0.503 0.204 0.015 11500.0 0.303 32.200 2.278 948.688 0.102 0.011 3.716 0.535 0.221 0.017 12000.0 0.301 31.750 2.360 948.394 0.108 0.012 3.804 0.567 0.239 0.020 12500.0 0.2899 31.305 2.441 948.099 0.114 0.013 3.888 0.599 0.257 0.022 13000.0 0.297 30.864 2.521 947.803 0.120 0.014 3. 969 0.632 0.275 0.025 13500.0 0.295 30.427 2.600 947.507 0.126 0.016 4 .046 0. 665 0.293 0.027 14000.0 0.293 29.994 2.678 947.209 0.133 0.017 4 .121 0. 698 0.312 0.030 14600.0 0.291 29.566 2.755 946.910 0.139 0.018 4.193 0.731 0.331 0.034 15000.0 0.289 29.141 2.831 946.610 0.146 0.020 4.263 0.765 0.351 0.037 16500.0 0.287 28.721 2.907 946.309 0.153 0.022 4 .330 0.798 0.370 0.041 17500.0 0.280 27.078 3.197 945.093 0.181 0.029 4.673 0 .933 0.450 0.057 20000.0 0.271 25.112 3.540 943.544 0.218 0.039 4 .827 1.102 0.552 0.081 22500.0 0.262 23.239 3.860 941.965 0.256 0.052 5.032 1 .271 0.653 0.111 25000.0 0.253 21.457 4.158 940.353 0.295 0.068 5.196 1 .438 0.752 0.145 27500.0 0.244 19. 762 4.434 938.707 0.335 0.085 5.323 1 .602 0.848 0.185 30000.0 0.235 18.155 4.690 937.028 0.375 0.105 5.418 1.762 0.940 0.229 32500.0 0.227 16.632 4.926 935.314 0.416 0.127 9.485 1.917 1.027 0.278 35000.0 0.218 15. 191 5.141 933.563 0.456 0.151 5.528 2.067 1.108 0.331 37500.0 0.210 13.632 5.337 931.776 0.497 0.178 5.551 2.210 1.183 0.388 40000.0 0.202 12.554 5.513 929.949 0.537 0.206 5.556 2.346 1.251 0.450 42500.0 0.194 11.355 5.671 928.084 0.576 0.237 5.546 2 .474 1.314 0.516 45000.0 0.187 10.234 5.809 926.180 0.614 0.269 5.524 2.595 1.370 0.565 47500.0 0.179 9.190 5.930 924.234 0.651 0.302 5.492 2.707 1.420 0.657 50000.0 0.172 8.222 6.032 922.248 0.687 0.337 5.452 2.911 1.464 0.732 52500.0 0.165 7.327 6.118 920.221 0.721 0.373 5.406 2. 906 1.502 0.811 55000.0 0.158 6.504 6.188 918.153 0.754 0.408 5.356 2. 993 1.534 0.892 57500.0 0.152 5.751 6.241 916.044 0.784 0.445 5.303 3. 071 1.562 0. 975 60000.0 0.145 5.0 65 6.280 913.895 0.813 0.480 5.249 3.141 1.594 1.060 62500.0 0.139 4.443 6.304 911.707 0.839 0.516 5.194 3.203 1.602 1.147 65000.0 0.133 3.683 6.314 909.482 0.864 0.551 5.140 3.258 1.617 1.235 67500.0 0.128 3.381 6.312 907.220 0.886 0.584 5.088 3.305 1.627 1.324 70000.0 0.122 2.934 6.298 904.924 0.906 0.616 5.038 3.345 1.635 1.415 AREVA Inc.
Contrail edDocunent Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page C-20 Table C.19 [ ] Exposure-Dependent 0% Void Isotopics (kg/MTU Initial)
Exposure kdWd/MTU U-234 U-235 U-236 0-238 NP-237 PU-238 2U-239 PU-240 90-241 9U-242 0.0 0.360 44.948 0.000 954.092 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.359 44.828 0.023 904.640 0.000 0.000 0.021 0.000 0.000 0.000 500.0 0.358 44.351 0.113 954.430 0.002 0.000 0.193 0.001 0.000 0.000 1000.0 0.356 43.762 0.224 954.168 0.003 0.000 0.411 0.006 0.000 0.000 1500.0 0.354 43.181 0.333 953.905 0.006 0.000 0.618 0.015 0.001 0.000 2000.0 0.352 42.607 0.440 953.642 0.006 0.000 0.617 0.025 0.002 0.000 2500.0 0.350 42.041 0.546 953.379 0.010 0.000 1.006 0.039 0.004 0.000 3000.0 0.348 41.463 0.650 953.116 0.013 0.000 1.187 0.054 0.007 0.000 3500.0 0.346 40.930 0.753 952.853 0.016 0.000 1.360 0.072 0.011 0.000 4000.0 0.344 40.385 0.854 952.589 0.019 0.001 1.525 0.091 0.015 0.000 4500.0 0.342 39.846 0.954 952.326 0.023 0.001 1.683 0.111 0.021 0.001 5000.0 0.340 39.312 1.053 952.062 0.026 0.001 1.833 0.133 0.028 0.001 5500.0 0.338 38.755 1.150 951.799 0.030 0.001 1.977 0.156 0.035 0.001 6000.0 0.336 38.263 1.245 951.536 0.033 0.002 2.115 0.180 0.043 0.002 6500.0 0.324 37.747 1.340 951.271 0.037 0.002 2.247 0.205 0.053 0.002 7000.0 0.332 37.236 1.433 951.008 0.041 0.002 2.372 0.231 0.063 0.003 7500.0 0.330 36.731 1.525 950.744 0.045 0.003 2.492 0.257 0.073 0.004 8000.0 0.328 36.230 1.616 950.480 0.050 0.003 2.606 0.284 0.085 0.005 8500.0 0.327 35.735 1.705 950.216 0.054 0.004 2.715 0.312 0.097 0.006 9000.0 0.325 35.244 1.794 949.952 0.059 0.004 2.819 0.340 0.110 0.007 9500.0 0.323 34.758 1.881 949.668 0.063 0.005 2.918 0.369 0.123 0.008 10000.0 0.321 34.276 1.967 949.425 0.068 0.005 3.012 0.398 0.137 0.010 10500.0 0.319 33.799 2.052 949.161 0.073 0.006 3.102 0.428 0.151 0.011 11000.0 0.317 33.326 2.136 948.897 0.078 0.007 3.187 0.458 0.166 0.013 11500.0 0.316 32.858 2.219 948.634 0.083 0.008 3.268 0.488 0.182 0.015 12000.0 0.314 32.393 2.301 948.370 0.088 0.008 3.344 0.519 0.197 0.017 12500.0 0.312 31.933 2.382 948.107 0.093 0.009 3.417 0.550 0.213 0.020 13000.0 0.310 31.476 2.462 947.844 0.099 0.010 3.486 0.581 0.229 0.022 13500.0 0.308 31.024 2.541 947.581 0.104 0.011 3.551 0.612 0.246 0.025 14000.0 0.307 30.575 2.619 947.318 0.110 0.012 3.612 0.644 0.262 0.028 14500.0 0.305 30.130 2.696 947.056 0.115 0.013 3.670 0.676 0.279 0.031 15000.0 0.303 29.688 2.772 946.793 0.121 0.014 3.724 0.707 0.296 0.034 15500.0 0.302 29.250 2.847 946.532 0.126 0.015 3.775 0.739 0.312 0.038 16000.0 0.300 28.815 2.921 946.270 0.132 0.017 3.522 0.771 0.329 0.041 16500.0 0.299 28.384 2.995 946.008 0.138 0.018 3.867 0.803 0.346 0.045 17000.0 0.296 27.956 3.067 945.747 0.144 0.019 3.909 0.836 0.363 0.049 17500.0 0.295 27.531 3.139 945.486 0.149 0.021 3.948 0.868 0.380 0.053 18000.0 0.293 27.109 3.210 945.224 0.155 0.022 3.984 0.900 0.397 0.058 18500.0 0.291 26.690 3.280 944.962 0.161 0.023 4.018 0.932 0.413 0.062 19000.0 0.290 26.275 3.349 944.700 0.167 0.025 4.050 0.964 0.430 0.067 19500.0 0.288 25.863 3.418 944.437 0.173 0.027 4.080 0.996 0.447 0.072 20000.0 0.286 25.454 3.485 944.174 0.179 0.028 4.109 1.027 0.464 0.077 20500.0 0.285 25.048 3.552 943.910 0.185 0.030 4.134 1.059 0.480 0.082 21000.0 0.283 24.646 3.618 943.644 0.191 0.032 4.159 1.091 0.497 0.088 21500.0 0.281 24.247 3.684 943.377 0.197 0.034 4.182 1.122 0.514 0.094 22000.0 0.280 23.851 3.748 943.110 0.204 0.035 4.204 1.153 0.530 0.100 22500.0 0.278 23.458 3.812 942.840 0.210 0.037 4.224 1.185 0.547 0.106 25000.0 0.270 21.546 4.119 941.473 0.242 0.049 4.307 1.337 0.629 0.140 27500.0 0.262 19.716 4.407 940.068 0.276 0.061 4.361 1.484 0.708 0.180 30000.0 0.253 17.971 4.675 938.624 0.311 0.076 4.390 1.626 0.783 0.225 32500.0 0.246 16.309 4.924 937.140 0.346 0.092 4.398 1.762 0.853 0.276 35000.0 0.237 14.732 5.154 935.612 0.382 0.110 4.388 1.891 0.916 0.333 37500.0 0.229 13.240 5.364 934.039 0.418 0.130 4.363 2.013 0.973 0.394 40000.0 0.221 11.835 5.555 932.417 0.453 0.152 4.325 2.127 1.024 0.461 42500.0 0.213 10.517 5.727 930.743 0.489 0.175 4.277 2.233 1.068 0.533 45000.0 0.205 9.287 5.879 929.017 0.524 0.200 4.222 2.330 1.105 0.610 47500.0 0.197 8.147 6.012 927.234 0.558 0.225 4.161 2.419 1.136 0.691 50000.0 0.189 7.096 6.125 925.393 0.591 0.252 4.097 2.499 1.161 0.776 52500.0 0.181 6.136 6.219 923.492 0.523 0.279 4.031 2.570 1.180 0.865 55000.0 0.174 5.266 6.294 921.530 0.653 0.305 3.965 2.632 1.194 0.957 57500.0 0.166 4.484 6.350 919.505 0.681 0.333 3.900 2.685 1.203 1.053 60000.0 0.159 3.788 6.389 917.420 0.708 0.359 3.837 2.730 1.209 1.150 62500.0 0.152 3.176 6.410 915.273 0.732 0.384 3.778 2.767 1.211 1.250 65000.0 0.145 2.643 6.416 913.069 0.754 0.408 3.723 2.796 1.210 1.350 67500.0 0.138 2.193 6.406 910.809 0.774 0.431 3.673 2.819 1.208 1.451 70000.0 0.131 1.792 6.384 908.498 0.792 0.452 3.627 2.837 1.203 1.553 AREVA Inc.
Con 4roH., dDocument Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page C-21 Table C.20 [ J Exposure-Dependent 40% Void Isotopics (kg/MTU Initial)
Exposure
- 0qd/lMTU U1-234 U1-235 U1-236 U1-238 NP-237 PU1-238 51U-239 51U-240 51U-241 PU1-242 0.0 0.360 44.948 0.000 954.692 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.359 44.929 0.024 954.633 0.000 0.000 0.023 0.000 0.000 0.000 500.0 0.357 44.353 0.117 554.394 0.002 0.000 0.218 0.002 0.000 0.000 1000.0 0.355 43.767 0.232 954.095 0.004 0.000 0.465 0.007 0.000 0.000 1500.0 0.353 43.190 0.345 553.796 0.007 0.000 0.699 0.016 0.001 0.000 2000.0 0.351 42.622 0.456 953.497 0.009 0.000 0.923 0.029 0.003 0.000 2500.0 0.348 42.062 0.565 953.198 0.012 0.000 1.137 0.043 0.006 0.000 3000.0 0.346 41.510 0.673 952.899 0.016 0.000 1.342 0.060 0.009 0.000 3500.0 0.344 40.966 0.779 952.600 0.019 0.001 1.537 0.079 0.014 0.000 4000.0 0.342 40.429 0.882 952.302 0.023 0.001 1.724 0.100 0.020 0.001 4500.0 0.340 39.898 0.984 952.003 0.027 0.001 1.902 0.122 0.027 0.001 5000.0 0.337 39.374 1.085 951.704 0.031 0.001 2.073 0.146 0.035 0.001 5500.0 0.335 38.857 1.184 951.405 0.035 0.002 2.236 0.170 0.044 0.002 6000.0 0.333 38.346 1.282 951.107 0.040 0.002 2.392 0.196 0.054 0.002 6900.0 0.331 37.841 1.378 950.808 0.044 0.003 2.542 0.223 0.065 0.003 7000.0 0.329 37.342 1.473 950.510 0.049 0.003 2.684 0.250 0.078 0.004 7500.0 0.327 36.648 1.566 950.211 0.054 0.004 2.821 0.278 0.090 0.006 9000.0 0.325 36.360 1.658 949.913 0.059 0.004 2.952 0.307 0.104 0.006 8500.0 0.323 35.877 1.749 949.615 0.064 0.005 3.077 0.337 0.119 0.007 9000.0 0.321 35.399 1.838 949.317 0.070 0.006 3.196 0.367 0.134 0.008 9600.0 0.319 34.927 1.927 949.019 0.075 0.006 3.310 0.397 0.150 0.010 10000.0 0.317 34.459 2.013 949.721 0.081 0.007 3.418 0.428 0.156 0.012 10500.0 0.315 33.996 2.099 948.423 0.087 0.008 3.522 0.459 0.183 0.013 11000.0 0.313 33.539 2.183 948.126 0.092 0.009 3.621 0.491 0.201 0.015 11500.0 0.311 33.084 2.267 947.829 0.098 0.010 3.715 0.523 0.218 0.018 12000.0 0.309 32.635 2.349 947.932 0.105 0.011 3.805 0.555 0.237 0.020 12500.0 0.307 32.190 2.430 947.235 0.111 0.012 3.890 0.588 0.255 0.023 13000.0 0.305 31.749 2.510 946.939 0.117 0.013 3.971 0.621 0.274 0.026 13500.0 0.303 31.312 2.589 946.642 0.123 0.015 4.048 0.654 0.293 0.029 14000.0 0.301 30.879 2.666 946.347 0.130 0.016 4.121 0.687 0.312 0.032 14500.0 0.299 30.451 2.743 946.051 0.136 0.017 4.190 0.720 0.331 0.035 15000.0 0.297 30.026 2.819 945.756 0.143 0.019 4.255 0.754 0.350 0.039 15500.0 0.296 29.604 2.894 945.461 0.149 0.020 4.317 0.787 0.370 0.042 16000.0 0.294 29.187 2.968 945.166 0.156 0.022 4.376 0.821 0.389 0.046 16500.0 0.292 28.773 3.041 944.872 0.162 0.023 4.431 0.855 0.409 0.051 17000.0 0.290 28.362 3.113 944.578 0.169 0.025 4.483 0.889 0.428 0.055 17500.0 0.288 27.955 3.184 944.284 0.176 0.027 4.532 0.923 0.447 0.060 18000.0 0.286 27.551 3.254 943.990 0.182 0.029 4.578 0.956 0.467 0.064 18500.0 0.285 27.151 3.323 943.696 0.189 0.031 4.621 0.990 0.466 0.069 19000.0 0.283 26.754 3.392 943.402 0.196 0.033 4.662 1.024 0.505 0.074 19500.0 0.281 26.360 3.459 943.107 0.203 0.035 4.701 1.058 0.524 0.080 20000.0 0.279 25.969 3.526 942.812 0.210 0.037 4.737 1.091 0.544 0.085 20500.0 0.278 25.582 3.592 942.516 0.217 0.039 4.772 1.125 0.563 0.091 21000.0 0.276 25.198 3.657 942.220 0.224 0.041 4.804 1.158 0.582 0.097 21500.0 0.274 24.817 3.721 941.923 0.231 0.043 4.835 1.191 0.601 0.103 22000.0 0.272 24.440 3.784 941.624 0.238 0.046 4.864 1.224 0.619 0.109 22500.0 0.271 24.066 3.847 941.325 0.245 0.048 4.892 1.257 0.638 0.16 23000.0 0.269 23.695 3.909 941.025 0.253 0.051 4.918 1.290 0.657 0.123 23500.0 0.267 23.327 3.970 940.723 0.260 0.054 4.943 1.322 0.676 0.130 25000.0 0.262 22.245 4.147 939.810 0.292 0.062 5.009 1.419 0.731 0.152 27500.0 0.253 20.506 4.429 938.261 0.320 0.075 5.095 1.575 0.822 0.192 30000.0 0.245 18.850 4.689 936.677 0.358 0.096 5.155 1.725 0.908 0.238 32500.0 0.237 17.275 4.930 935.057 0.397 0.116 5.192 1.869 0.989 0.289 35000.0 0.229 15.781 5.152 933.399 0.436 0.138 5.208 2.006 1.064 0.344 37500.0 0.220 14.367 5.356 931.702 0.475 0.162 5.207 2.137 1.133 0.404 40000.0 0.213 13.032 5.540 929.965 0.514 0.189 5.192 2.260 1.196 0.468 42500.0 0.205 11.776 5.706 928.187 0.552 0.216 5.164 2.375 1.252 0.536 45000.0 0.197 10.599 5.854 926.356 0.589 0.246 5.127 2.492 1.301 0.608 47500.0 0.190 9.499 5.984 924.502 0.625 0.277 5.091 2.582 1.344 0.584 50000.0 0.182 8.476 6.097 922.593 0.660 0.308 5.029 2.673 1.381 0.763 52500.0 0.175 7.530 6.192 920.640 0.694 0.341 4.973 2.755 1.412 0.845 55000.0 0.168 6.659 6.271 918.640 0.726 0.374 4.914 2.830 1.437 0.929 57500.0 0.161 5.860 6.333 916.595 0.757 0.407 4.853 2.896 1.457 1.015 60000.0 0.155 5.134 6.379 914.505 0.786 0.440 4.792 2.955 1.473 1.103 52500.0 0.148 4.476 6.410 912.369 0.812 0.472 4.732 3.008 1.485 1.193 65000.0 0.142 3.884 6.427 910.191 0.837 0.503 4.673 3.090 1.493 1.284 67500.0 0.136 3.355 6.431 907.970 0.860 0.533 4.516 3.087 1.497 1.375 70000.0 0.130 2.885 6.422 905.709 0.880 0.562 4.563 3.118 1.499 1.467 AREVA Inc.
ControiLed Dociment Nuclear Fuel Design Report ANP-g294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page C-22 Table C.21 [ ] Exposure-Dependent 80% Void Isotopics (kgIMTU Initial)
Exposure I4Wd/MTU U3-234 U-235 U-236 U-238 14P-237 PU-238 P0-239 PU-240 P0-241 P0-242 0.0 0.360 44.548 0.000 954.692 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.359 44.829 0.029 994.623 0.000 0.000 0.027 0.000 0.000 0.000 900.0 0.397 44.357 0.123 954.346 0.002 0.000 0.251 0.002 0.000 0.000 1000.0 0.354 43.776 0.243 904.000 0.005 0.000 0.533 0.009 0.001 0.000 1500.0 0.352 43.206 0.361 953.694 0.008 0.000 0.802 0.018 0.002 0.000 2000.0 0.349 42.646 0.477 953.308 0.011 0.000 1.059 0.032 0.004 0.000 2500.0 0.347 42.094 0.590 952.962 0.015 0.000 1.309 0.048 0.007 0.000 3000.0 0.344 41.551 0.702 952.617 0.019 0.001 1.540 0.066 0.012 0.000 3500.0 0.342 41.017 0.811 992.271 0.023 0.001 1.765 0.067 0.018 0.000 4000.0 0.339 40.490 0.919 951.926 0.028 0.001 1.981 0.109 0.026 0.001 4500.0 0.337 39.970 1.025 951.081 0.033 0.002 2.188 0.133 0.034 0.001 5000.0 0.334 39.458 1.129 951.237 0.038 0.002 2.386 0.157 0.044 0.001 5500.0 0.332 38.953 1.231 950.892 0.043 0.003 2.076 0.184 0.056 0.002 6000.0 0.329 38.405 1.331 950.547 0.048 0.003 2.798 0.211 0.068 0.003 6000.0 0.327 37.963 1.430 950.203 0.054 0.004 2.933 0.239 0.081 0.003 7000.0 0.329 37.477 1.527 949.859 0.060 0.004 3.101 0.268 0.096 0.004 7500.0 0.322 36.997 1.623 949.515 0.066 0.005 3.263 0.297 0.111 0.005 8000.0 0.320 36.523 1.717 949.171 0.072 0.006 3.418 0.328 0.127 0.007 9500.0 0.318 36.055 1.810 948.828 0.079 0.007 3.566 0.358 0.144 0.008 9000.0 0.315 35.592 1.901 948.484 0.085 0.008 3.709 0.390 0.162 0.009 9500.0 0.313 35.135 1.991 948.141 0.092 0.009 3.846 0.422 0.180 0.011 10000.0 0.311 34.683 2.080 947.798 0.099 0.010, 3.977 0.455 0.159 0.013 10500.0 0.309 34.236 2.187 947.455 0.106 0.011 4.103 0.488 0.219 0.015 11000.0 0.306 33.794 2.253 947.113 0.113 0.013 4.223 0.521 0.235 0.017 11500.0 0.304 33.357 2.337 946.771 0.120 0.014 4.339 0.555 0.259 0.020 12000.0 0.302 32.924 2.421 946.428 0.127 0.015 4.450 0.590 0.280 0.022 12500.0 0.300 32.496 2.503 946.087 0.134 0.017 4.556 0.624 0.301 0.025 13000.0 0.298 32.073 2.584 945.746 0.142 0.019 4.658 0.659 0.322 0.028 13500.0 0.296 31.654 2.664 945.405 0.149 0.020 4.755 0.694 0.344 0.031 14000.0 0.293 31.239 2.742 945.064 0.157 0.022 4.848 0.729 0.365 0.035 14500.0 0.291 30.829 2.820 944.724 0.165 0.024 4.937 0.765 0.387 0.038 15000.0 0.288 30.422 2.896 944.384 0.172 0.026 5.022 0.801 0.409 0.042 15500.0 0.287 30.020 2.871 944.044 0.180 0.028 5.103 0.837 0.431 0.046 16000.0 0.285 29.621 3.045 943.705 0.188 0.030 5.180 0.873 0.453 0.050 16500.0 0.283 29.226 3.118 943.366 0.196 0.032 5.254 0.909 0.475 0.054 17000.0 0.281 28.835 3.190 943.027 0.204 0.035 5.324 0.945 0.497 0.059 17500.0 0.279 28.448 3.262 942.688 0.212 0.037 5.391 0.982 0.519 0.063 18000.0 0.277 28.064 3.332 942.350 0.220 0.040 5.455 1.018 0.541 0.068 18500.0 0.275 27.683 3.401 542.011 0.228 0.042 5.516 1.055 0.563 0.073 19000.0 0.273 27.307 3.469 941.673 0.236 0.045 5.574 1.091 0.585 0.078 19500.0 0.271 26.933 3.536 541.335 0.244 0.048 5.629 1.128 0.607 0.084 20000.0 0.270 26.563 3.602 540.996 0.252 0.051 5.682 1.164 0.628 0.089 20500.0 0.268 26.197 3.668 940.657 0.260 0.054 5.732 1.201 0.650 0.095 21000.0 0.266 25.534 3.732 940.318 0.268 0.057 5.780 1.237 0.671 0.101 21500.0 0.264 25.474 3.796 939.878 0.276 0.060 5.826 1.274 0.693 0.107 22000.0 0.262 25.117 3.859 939.637 0.284 0.063 5.870 1.310 0.714 0.113 22500.0 0.260 24.764 3.920 539.296 0.292 0.066 5.912 1.346 0.736 0.120 23000.0 0.258 24.414 3.981 393.954 0.301 0.070 5.952 1.382 0.757 0.126 23500.0 0.257 24.067 4.042 938.611 0.309 0.073 5.991 1.418 0.778 0.133 24000.0 0.255 23.724 4.101 938.267 0.317 0.077 6.028 1.453 0.799 0.140 24500.0 0.253 23.384 4.159 937.922 0.325 0.081 6.063 1.489 0.820 0.147 20000.0 0.251 23.047 4.217 937.576 0.334 0.084 6.097 1.524 0.841 0.155 25500.0 0.249 22.713 4.274 937.229 0.342 0.088 6.130 1.559 0.961 0.162 26000.0 0.249 22.383 4.330 936.880 0.350 0.092 6.161 1.694 0.882 0.170 26500.0 0.246 22.056 4.385 936.531 0.359 0.096 6.191 1.629 0.903 0.178 27000.0 0.244 21.732 4.440 936.180 0.367 0.101 6.220 1.663 0.923 0.186 27500.0 0.242 21.411 4.493 935.828 0.375 0.105 6.248 1.658 0.943 0.194 30000.0 0.233 19.855 4.749 934.049 0.418 0.128 6.365 1.866 1.043 0.237 32500.0 0.225 18.377 4.985 932.237 0.460 0.154 6.464 2.028 1.139 0.284 35000.0 0.217 16.976 5.202 930.394 0.502 0.182 6.536 2.185 1.230 0.335 37000.0 0.209 15.650 5.400 928.519 0.545 0.212 6.589 2.335 1.316 0.350 40000.0 0.201 14.397 5.580 926.610 0.086 0.245 6.624 2.479 1.396 0.448 42500.0 0.193 13.216 5.741 524.669 0.627 0.280 6.644 2.616 1.470 0.509 45000.0 0.186 12.105 5.885 922.694 0.667 0.317 6.650 2.746 1.539 0.573 47500.0 0.179 11.063 6.012 920.686 0.706 0.355 6.646 2.868 1.602 0.639 50000.0 0.172 10.087 6.123 918.646 0.743 0.395 6.632 2.984 1.659 0.709 52500.0 0.166 9.177 6.218 916.572 0.779 0.436 6.610 3.091 1.710 0.780 550000.0 0.159 8.329 6.298 514.467 0.814 0.478 6.582 3.192 1.757 0.854 57500.0 0.153 7.542 6.363 912.329 0.847 0.520 6.549 3.285 1.798 0.929 60000.0 0.147 6.814 6.414 910.161 0.877 0.563 6.512 3.371 1.830 1.007 62500.0 0.142 6.142 6.452 907.962 0.906 0.605 6.472 3.450 1.867 1.086 65000.0 0.136 5.523 6.477 905.734 0.933 0.647 6.430 3.522 1.895 1.166 67000.0 0.131 4.957 6.491 903.478 0.958 0.689 6.388 3.588 1.920 1.247 70000.0 0.127 4.439 6.493 501.195 0.981 0.729 6.344 3.647 1.940 1.330 AREVA Inc.
Controled Documrent Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page C-23 Table C.22 [ ] Exposure-Dependent 0% Void Isotopics (kg/MTU Initial)
Exposure 0.9d/MTU 0-234 0-235 U-236 U-238 NP-237 PU-238 PU-239 P0-240 PU-241 P0-242 0.0 0.354 44.251 0.000 855.395 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.354 44.131 0.022 855.345 0.000 0.000 0.018 0.000 0.000 0.000 500.0 0.352 43.653 0.I11 850.142 0.002 0.000 0.182 0.001 0.000 0.000 1000.0 0.350 43.063 0.221 854.888 0.003 0.000 0.353 0.006 0.000 0.000 1500.0 0.348 42.481 0.325 854.636 0.005 0.000 0.594 0.014 0.001 0.000 2000.0 0.346 41.806 0.4385954.382 0.008 0.000 0.785 0.025 0.002 0.000 2500.0 0.344 41.339 0.540 954.128 0.010 0.000 0.868 0.037 0.004 0.000 3000.0 0.343 40.778 0.643 853.876 0.013 0.000 1.142 0.053 0.007 0.000 3500.0 0.341 40.224 0.745 953.823 0.015 0.000 1.309 0.070 0.010 0.000 4000.0 0.338 38.677 0.845 953.370 0.018 0.001 1.487 0.088 0.014 0.000 4500.0 0.337 38.135 0.844 953.117 0.021 0.001 1.618 0.108 0.020 0.001 5000.0 0.335 38.600 1.041 952.865 0.025 0.001 1.753 0.130 0.026 0.001 5500.0 0.333 38.070 1.137 852.612 0.028 0.001 1.800 0.152 0.033 0.001 6000.0 0.331 37.545 1.232 852.360 0.032 0.002 2.031 0.176 0.041 0.002 5500.0 0.330 37.026 1.325 852.108 0.035 0.002 2.156 0.200 0.048 0.002 7000.0 0.328 36.512 1.418 881.856 0.038 0.002 2.274 0.226 0.059 0.003 7500.0 0.326 36.004 1.509 851.804 0.043 0.003 2.387 0.252 0.068 0.004 6000.0 0.324 35.500 1.588 851.353 0.047 0.003 2.485 0.278 0.080 0.004 8500.0 0.322 35.000 1.688 851.101 0.051 0.003 2.586 0.306 0.081 0.005 8000.0 0.321 34.508 1.775 850.850 0.055 0.004 2.883 0.334 0.103 0.007 8500.0 0.318 34.016 1.862 850.600 0.058 0.004 2.785 0.383 0.116 0.008 10000.0 0.317 33.530 1.847 850.350 0.064 0.005 2.872 0.382 0.128 0.008 10500.0 0.315 33.048 2.032 850.100 0.068 0.008 2.855 0.421 0.143 0.011 11000.0 0.314 32.571 2.115 848.850 0.073 0.006 3.032 0.451 0.157 0.012 11500.0 0.312 32.088 2.187 848.801 0.078 0.007 3.106 0.481 0.171 0.014 12000.0 0.310 31.828 2.278 848.352 0.082 0.008 3.175 0.511 0.185 0.016 12500.0 0.308 31.183 2.358 848.103 0.087 0.008 3.240 0.542 0.200 0.018 13000.0 0.307 30.701 2.439 548.856 0.082 0.009 3.302 0.573 0.215 0.021 13500.0 0.305 30.243 2.517 848.808 0.087 0.010 3.358 0.604 0.231 0.024 14000.0 0.304 28.788 2.585 848.361 0.102 0.011 3.413 0.635 0.248 0.026 14500.0 0.302 28.338 2.871 848.115 0.107 0.012 3.463 0.866 0.262 0.028 15000.0 0.300 28.888 2.747 847.868 0.112 0.013 3.510 0.888 0.277 0.032 15500.0 0.288 28.443 2.822 847.824 0.117 0.014 3.553 0.730 0.283 0.036 15000.0 0.287 28.001 2.886 847.378 0.123 0.015 3.583 0.781 0.308 0.038 16500.0 0.285 27.563 2.888 847.135 0.128 0.016 3.631 0.783 0.324 0.043 17000.0 0.284 27.127 3.042 846.880 0.133 0.017 3.668 0.825 0.340 0.047 17500.0 0.282 26.885 3.114 848.848 0.138 0.018 3.688 0.856 0.355 0.051 18000.0 0.281 26.265 3.184 846.400 0.144 0.020 3.728 0.888 0.371 0.055 18500.0 0.288 25.838 3.255 846.155 0.148 0.021 3.758 0.820 0.388 0.058 18000.0 0.287 25.418 3.324 845.808 0.155 0.022 3.782 0.851 0.402 0.064 18500.0 0.286 24.887 3.383 845.661 0.180 0.024 3.807 0.883 0.417 0.088 20000.0 0.284 24.580 3.480 845.412 0.166 0.025 3.830 1.014 0.433 0.074 20500.0 0.283 24.167 3.527 845.183 0.171 0.026 3.851 1.045 0.445 0.078 22500.0 0.276 22.547 3.788 844.150 0.184 0.033 3.823 1.188 0.511 0.102 25000.0 0.268 20.588 4.087 842.850 0.224 0.043 3.885 1.318 0.589 0.135 27500.0 0.260 18.730 4.386 841.512 0.256 0.054 4.020 1.463 0.863 0.175 30000.0 0.252 18.848 4.858 840.132 0.288 0.086 4.032 1.803 0.732 0.220 32500.0 0.344 15.255 4.807 538.707 0.321 0.081 4.024 1.737 0.786 0.271 35000.0 0.236 13.648 5.138 837.234 0.355 0.087 4.000 1.864 0.853 0.328 37500.0 0.228 12.132 5.350 835.710 0.388 0.115 3.862 1.883 0.804 0.381 40000.0 0.220 10.707 5.541 834.130 0.422 0.134 3.814 2.084 0.848 0.460 42500.0 0.212 8.378 5.712 832.481 0.456 0.155 3.857 2.187 0.886 0.534 45000.0 0.204 8.145 5.882 830.788 0.488 0.177 3.785 2.280 1.017 0.614 47500.0 0.185 7.012 5.881 828.021 0.521 0.200 3.728 2.375 1.042 0.888 50000.0 0.187 5.880 6.088 827.183 0.552 0.223 3.662 2.448 1.081 0.788 52500.0 0.178 5.050 8.188 825.273 0.582 0.247 3.585 2.514 1.074 0.883 55000.0 0.171 4.221 6.253 823.288 0.810 0.271 3.530 2.570 1.083 0.882 57500.0 0.163 3.481 8.288 821.230 0.637 0.284 3.468 2.818 1.088 1.083 80000.0 0.158 2.858 8.328 818.088 0.681 0.317 3.411 2.853 1.088 1.187 62500.0 0.147 2.318 6.335 818.887 0.683 0.338 3.358 2.683 1.088 1.283 85000.0 0.140 1.882 8.327 814.830 0.703 0.358 3.312 2.705 1.085 1.401 67500.0 0.132 1.483 6.305 812.302 0.720 0.377 3.271 2.721 1.080 1.508' 70000.0 0.128 1.173 6.268 808.820 0.735 0.383 3.235 2.732 1.075 1.815 AREVA Inc.
Controlled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 1OXM Fuel Page C-24 Table C.23 [ ] Exposure-Dependent 40%
Void Isotopics (kgIMTU Initial)
Exposure MWd/MTU0 0-234 0-235 0-236 0-235 NP-237 PU-238 PU-239 PU-240 P0-241 PU-242 0.0 0.354 44.251 0.000 955.395 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.354 44.131 0.023 955.337 0.000 0.000 0.021 0.000 0.000 0.000 500.0 0.352 43.655 0.116 555.106 0.002 0.000 0.207 0.002 0.000 0.000 1000.0 0.350 43.065 0.229 954.817 0.004 0.000 0.446 0.007 0.000 0.000 1500.0 0.347 42.490 0.341 954.526 0.006 0.000 0.674 0.016 0.001 0.000 2000.0 0.345 41.920 0.451 954.239 0.009 0.000 0.591 0.025 0.003 0.000 2500.0 0.343 41.258 0.559 953.951 0.012 0.000 1.098 0.042 0.005 0.000 3000.0 0.341 40.804 0.665 953.663 0.015 0.000 1.255 0.059 0.009 0.000 3500.0 0.339 40.257 0.769 553.375 0.015 0.001 1.453 0.077 0.013 0.000 4000.0 0.337 39.715 0.872 553.066 0.022 0.001 1.662 0.098 0.019 0.000 4500.0 0.335 39.155 0.573 552.501 0.025 0.001 1.534 0.120 0.025 0.001 5000.0 0.333 38.659 1.073 952.514 0.029 0.001 1.997 0.143 0.033 0.001 5500.0 0.331 35.139 1.171 952.228 0.033 0.002 2.153 0.157 0.042 0.001 6000.0 0.329 37.625 1.267 951.942 0.037 0.002 2.301 0.193 0.051 0.002 6500.0 0.327 37.117 1.363 551.656 0.042 0.002 2.443 0.219 0.062 0.003 7000.0 0.325 36.614 1.456 551.371 0.046 0.003 2.575 0.246 0.074 0.003 7500.0 0.323 36.117 1.549 551.056 0.051 0.003 2.706 0.274 0.086 0.004 5000.0 0.321 35.625 1.640 950.802 0.055 0.004 2.528 0.303 0.095 0.005 5500.0 0.315 35.139 1.725 950.515 0.060 0.005 2.945 0.332 0.113 0.006 5000.0 0.317 34.657 1.815 950.235 0.065 0.006 3.055 0.362 0.127 0.005 9500.0 0.315 34.181 1.905 949.952 0.071 0.006 3.161 0.392 0.143 0.009 10000.0 0.313 33.708 1.991 545.665 0.076 0.007 3.261 0.422 0.158 0.011 10500.0 0.311 33.241 2.076 949.387 0.081 0.007 3.355 0.454 0.174 0.013 11000.0 0.309 32.778 2.160 945.106 0.087 0.008 3.445 0.485 0.151 0.015 11500.0 0.307 32.320 2.242 948.825 0.092 0.009 3.530 0.517 0.208 0.017 12000.0 0.306 31.865 2.323 948.545 0.098 0.010 3.611 0.545 0.225 0.019 12500.0 0.304 31.415 2.404 948.265 0.104 0.011 3.687 0.581 0.242 0.022 13000.0 0.302 20.969 2.453 947.986 0.105 0.012 3.758 0.614 0.260 0.024 13500.0 0.300 30.526 2.561 547.707 0.115 0.013 3.526 0.647 0.278 0.027 14000.0 0.298 30.058 2.635 947.430 0.121 0.014 3.889 0.680 0.256 0.030 14500.0 0.297 25.653 2.715 947.153 0.127 0.016 3.949 0.713 0.314 0.034 15000.0 0.255 29.221 2.790 946.576 0.133 0.017 4.004 0.746 0.332 0.037 15500.0 0.253 25.793 2.565 946.601 0.135 0.015 4.057 0.775 0.350 0.041 16000.0 0.251 28.368 2.935 946.325 0.145 0.019 4.105 0.813 0.368 0.045 16500.0 0.250 27.947 3.011 946.050 0.151 0.021 4.151 0.846 0.387 0.049 17000.0 0.285 27.529 3.082 545.776 0.157 0.022 4.194 0.850 0.405 0.053 17500.0 0.286 27.114 3.153 545.502 0.163 0.024 4.233 0.513 0.423 0.057 15000.0 0.284 26.702 3.223 945.227 0.169 0.025 4.271 0.947 0.441 0.062 15500.0 0.283 26.294 3.292 944.953 0.175 0.027 4.306 0.980 0.458 0.067 15000.0 0.281 25.885 3.361 944.678 0.182 0.029 4.339 1.013 0.475 0.072 19500.0 0.279 25.487 2.428 944.402 0.185 0.031 4.365 1.046 0.494 0.077 20000.0 0.275 25.088 3.495 944.125 0.194 0.032 4.398 1.079 0.512 0.082 20500.0 0.276 24.653 3.561 543.547 0.201 0.034 4.425 1.112 0.530 0.088 21000.0 0.274 24.300 3.626 543.569 0.207 0.036 4.451 1.145 0.548 0.094 21500.0 0.273 23.912 3.690 943.255 0.214 0.038 4.475 1.177 0.565 0.100 22500.0 0.265 23.144 3.817 942.725 0.227 0.043 4.515 1.242 0.601 0.112 25000.0 0.261 21.253 4.118 941.292 0.261 0.055 4.607 1.400 0.685 0.148 27500.0 0.253 15.506 4.400 935.822 0.257 0.066 4.666 1.552 0.773 0.165 30000.0 0.245 17.512 4.652 935.316 0.333 0.054 4.655 1.695 0.553 0.235 32500.0 0.236 16.201 4.505 936.770 0.369 0.102 4.711 1.539 0.527 0.256 35000.0 0.228 14.674 5.128 535.184 0.406 0.122 4.705 1.572 0.995 0.343 37500.0 0.220 13.230 5.332 933.554 0.443 0.143 4.683 2.095 1.057 0.405 40000.0 0.212 11.870 5.517 931.579 0.450 0.166 4.648 2.216 1.111 0.471 42500.0 0.204 10.554 5.682 930.156 0.516 0.191 4.602 2.326 1.159 0.542 45000.0 0.157 9.403 5.829 928.384 0.551 0.217 4.549 2.427 1.155 0.615 47500.0 0.185 5.258 5.557 926.560 0.586 0.244 4.490 2.520 1.234 0.695 50000.0 0.181 7.277 6.066 924.654 0.615 0.272 4.426 2.603 1.262 0.751 52500.0 0.174 6.342 6.157 922.752 0.651 0.301 4.361 2.675 1.284 0.565 55000.0 0.167 5.450 6.229 920.765 0.551 0.330 4.294 2.743 1.300 0.555 57500.0 0.155 4.722 6.254 515.723 0.705 0.358 4.229 2.800 1.312 1.051 60000.0 0.152 4.033 6.321 916.625 0.736 0.386 4.165 2.845 1.320 1.145 62500.0 0.145 3.422 5.343 514.473 0.751 0.414 4.104 2.658 1.324 1.241 65000.0 0.139 2.855 5.345 912.267 0.783 0.440 4.046 2.521 1.325 1.335 67500.0 0.132 2.417 6.340 910.012 0.503 0.465 3.993 2.947 1.323 1.437 70000.0 0.126 2.014 6.315 907.710 0.821 0.488 3.944 2.967 1.320 1.535 AREVA Inc.
ontro, da Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page C-25 Table C.24 [ ] Exposure-Dependent 80%
Void Isotopics (kg/MTU Initial)
Exposure M~Wd/MITU U-234 0-235 0-236 0-238 NP9-237 PU-238 P0-239 2U-240 PU-241 P0-242 0.0 0.354 44.251 0.000 955.395 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.353 44.132 0.024 955.328 0.000 0.000 0.024 0.000 0.000 0.000 500.0 0.351 43.658 0.122 955.059 0.002 0.000 0.228 0.002 0.000 0.000 1000.0 0.349 43.076 0.241 954.722 0.005 0.000 0.514 0.008 0.000 0.000 1500.0 0.346 42.504 0.358 954.386 0.008 0.000 0.776 0.018 0.002 0.000 2000.0 0.344 41.941 0.472 954.051 0.011 0.000 1.026 0.031 0.004 0.000 2500.0 0.341 41.387 0.584 853.716 0.014 0.000 1.265 0.047 0.007 0.000 3000.0 0.339 40.842 0.698 953.382 0.018 0.001 1.492 0.085 0.012 0.000 3500.0 0.337 40.305 0.803 953.049 0.022 0.001 1.710 0.085 0.017 0.000 4000.0 0.334 39.776 0.910 952.716 0.027 0.001 1.917 0.107 0.025 0.001 4500.0 0.332 39.254 1.014 982.384 0.031 0.001 2.116 0.131 0.033 0.001 5000.0 0.330 38.739 1.117 952.052 0.036 0.002 2.308 0.156 0.043 0.001 5500.0 0.327 38.231 1.218 951.721 0.041 0.002 2.487 0.182 0.054 0.002 6000.0 0.325 37.729 1.318 951.390 0.046 0.003 2.660 0.209 0.065 0.002 6500.0 0.323 37.234 1.415 951.060 0.051 0.003 2.826 0.236 0.079 0.003 7000.0 0.320 36.745 1.511 950.730 0.057 0.004 2.985 0.265 0.093 0.004 7500.0 0.318 36.262 1.608 950.401 0.063 0.005 3.136 0.295 0.108 0.005 8000.0 0.316 35.785 1.699 950.072 0.068 0.006 3.281 0.325 0.124 0.006 8500.0 0.314 35.313 1.791 949.745 0.075 0.006 3.419 0.356 0.140 0.008 9000.0 0.311 34.847 1.881 949.418 0.081 0.007 3.551 0.387 0.158 0.009 9500.0 0.309 34.386 1.970 949.091 0.087 0.008 3.677 0.419 0.175 0.011 10000.0 0.307 33.930 2.058 948.765 0.093 0.008 3.797 0.452 0.194 0.013 10500.0 0.305 33.479 2.144 948.440 0.100 0.010 3.912 0.485 0.213 0.015 11000.0 0.303 33.033 2.229 948.115 0.106 0.012 4.021 0.518 0.232 0.017 11500.0 0.301 32.591 2.313 947.791 0.113 0.013 4.125 0.552 0.252 0.019 12000.0 0.299 32.154 2.395 947.468 0.120 0.014 4.224 0.586 0.272 0.022 12500.0 0.297 31.722 2.476 947.145 0.127 0.016 4.318 0.620 0.292 0.025 13000.0 0.295 31.293 2.596 946.823 0.134 0.017 4.408 0.655 0.313 0.028 13500.0 0.293 30.969 2.635 946.502 0.141 0.019 4.492 0.690 0.333 0.031 14000.0 0.291 30.449 2.713 946.182 0.148 0.020 4.573 0.725 0.354 0.034 14500.0 0.289 30.033 2.790 945.862 0.155 0.022 4.649 0.761 0.375 0.038 15000.0 0.287 29.621 2.965 945.543 0.162 0.024 4.721 0.796 0.396 0.041 15500.0 0.285 29.213 2.940 945.225 0.169 0.025 4.789 0.832 0.417 0.045 16000.0 0.283 28.808 3.013 944.908 0.176 0.027 4.954 0.868 0.438 0.049 16500.0 0.281 28.407 3.086 944.591 0.184 0.029 4.918 0.904 0.459 0.053 17000.0 0.279 28.009 3.157 944.274 0.191 0.031 4.972 0.940 0.480 0.058 17500.0 0.277 27.615 3.228 943.958 0.198 0.033 5.026 0.976 0.500 0.063 19000.0 0.275 27.224 3.298 943.642 0.206 0.036 5.078 1.012 0.521 0.067 18500.0 0.274 26.836 3.366 943.326 0.213 0.039 5.126 1.048 0.542 0.072 19000.0 0.272 26.452 3.434 943.011 0.220 0.040 5.172 1.084 0.562 0.078 19500.0 0.270 26.071 3.501 942.695 0.228 0.043 5.215 1.120 0.583 0.083 20000.0 0.268 25.694 3.587 942.378 0.235 0.045 5.257 1.156 0.603 0.088 20500.0 0.266 25.320 3.632 942.061 0.243 0.048 5.296 1.192 0.624 0.094 21000.0 0.264 24.949 3.696 941.743 0.250 0.051 5.333 1.227 0.644 0.100 21500.0 0.263 24.991 3.760 941.424 0.258 0.053 5.368 1.263 0.664 0.106 22000.0 0.261 24.217 3.822 941.105 0.266 0.056 5.402 1.298 0.684 0.113 22500.0 0.259 23.856 3.884 940.784 0.273 0.059 5.434 1.333 0.705 0.119 23000.0 0.257 23.498 3.945 940.463 0.281 0.062 5.454 1.369 0.725 0.126 23500.0 0.256 23.144 4.005 940.140 0.289 0.065 5.493 1.403 0.745 0.133 25000.0 0.250 22.101 4.180 939.164 0.312 0.075 5.573 1.507 0.804 0.154 27500.0 0.242 20.428 4.456 937.511 0.351 0.093 5.680 1.675 0.902 0.194 30000.0 0.233 18.837 4.712 935.825 0.391 0.114 5.760 1.837 0.996 0.239 32500.0 0.225 17.324 4.948 934.105 0.432 0.137 5.815 1.993 1.084 0.288 39000.0 0.217 15.691 5.165 932.351 0.472 0.162 5.950 2.143 1.168 0.341 37500.0 0.209 14.535 5.363 930.561 0.512 0.189 5.966 2.296 1.245 0.399 40000.0 0.201 13.256 5.542 928.735 0.552 0.218 5.866 2.422 1.316 0.459 42500.0 0.193 12.052 5.702 926.872 0.591 0.249 5.853 2.550 1.380 0.524 45000.0 0.186 10.923 5.845 924.971 0.629 0.282 5.828 2.671 1.439 0.592 47500.0 0.179 9.867 5.969 923.032 0.666 0.316 5.795 2.783 1.491 0.663 50000.0 0.172 8.883 6.077 921.055 0.702 0.352 5.754 2.897 1.537 0.737 52500.0 0.165 7.970 6.168 919.039 0.736 0.388 5.707 2.983 1.577 0.814 55000.0 0.158 7.125 6.243 916.984 0.769 0.425 5.656 3.070 1.611 0.893 57500.0 0.152 6.348 6.303 914.891 0.800 0.462 5.602 3.150 1.641 0.974 60000.0 0.146 5.635 6.348 912.760 0.929 0.499 5.546 3.221 1.665 1.058 62500.0 0.140 4.984 6.378 910.592 0.856 0.536 5.490 3.285 1.685 1.143 65000.0 0.134 4.394 6.395 908.388 0.891 0.572 5.434 3.342 1.701 1.229 67500.0 0.128 3.860 6.400 906.149 0.904 0.607 9.379 3.391 1.713 1.317 70000.0 0.123 3.390 6.393 903.877 0.924 0.641 5.326 3.434 1.723 1.405 AREVA Inc.
Control!ed Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page C-26 Table C.25 [ ] Exposure-Dependent 0% Void Isotopics (kgIMTU Initial)
Exposure MWd/MTU0 U-234 U7-235 U7-236 U7-238 9P-237 91U-238 21U-239 PU7-240 91U-241 PU7-242 0.0 0.354 44.251 0.000 955.395 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.354 44.131 0.022 955.347 0.000 0.000 0.017 0.000 0.000 0.000 500.0 0.352 43.653 0.110 955.153 0.001 0.000 0.174 0.001 0.000 0.000 1000.0 0.350 43.063 0.219 954.911 0.003 0.000 0.375 0.006 0.000 0.000 1500.0 0.348 42.450 0.326 954.668 0.005 0.000 0.567 0.013 0.001 0.000 2000.0 0.347 41.904 0.431 954.426 0.007 0.000 0.751 0.023 0.002 0.000 2500.0 0.345 41.335 0.535 954.184 0.010 0.000 0.926 0.036 0.004 0.000 3000.0 0.343 40.773 0.637 953.941 0.012 0.000 1.093 0.050 0.006 0.000 3500.0 0.341 40.217 0.738 953.699 0.015 0.000 1.293 0.067 0.009 0.000 4000.0 0.339 39.667 0.837 953.457 0.018 0.001 1.404 0.085 0.013 0.000 4500.0 0.338 39.124 0.935 953.214 0.021 0.001 1.549 0.104 0.019 0.001 5000.0 0.336 39.555 1.032 952.972 0.024 0.001 1.586 0.125 0.024 0.001 5500.0 0.334 38.053 1.128 952.730 0.027 0.001 1.919 0.146 0.030 0.001 6000.0 0.332 37.525 1.222 952.488 0.030 0.001 1.943 0.169 0.037 0.001 6500.0 0.330 37.003 1.315 952.246 0.034 0.002 2.063 0.193 0.045 0.002 7000.0 0.329 36.486 1.407 952.005 0.037 0.002 2.175 0.218 0.054 0.003 7500.0 0.327 25.973 1.499 951.763 0.041 0.002 2.284 0.243 0.064 0.003 8000.0 0.325 35.466 1.588 951.522 0.045 0.003 2.387 0.269 0.074 0.004 8500.0 0.323 34.962 1.676 951.281 0.049 0.003 2.485 0.296 0.084 0.005 9000.0 0.322 34.464 1.764 951.040 0.053 0.004 2.577 0.323 0.096 0.006 9500.0 0.220 33.970 1.850 950.900 0.057 0.004 2.665 0.351 0.107 0.007 10000.0 0.318 23.479 1.936 950.560 0.051 0.005 2.748 0.379 0.120 0.009 10500.0 0.317 32.993 2.020 950.320 0.065 0.005 2.826 0.408 0.133 0.010 11000.0 0.315 32.511 2.004 950.080 0.070 0.006 2.901 0.437 0.145 0.012 10500.0 0.313 32.033 2.186 949.840 0.074 0.006 2.971 0.467 0.159 0.013 02000.0 0.312 31.559 2.267 949.502 0.079 0.007 3.037 0.496 0.173 0.015 12500.0 0.310 31.089 2.348 949.363 0.093 0.008 3.099 0.526 0.187 0.017 13000.0 0.308 30.622 2.427 949.125 0.088 0.009 3.197 0.557 0.201 0.020 13500.0 0.307 30.158 2.506 948.887 0.093 0.009 3.212 0.587 0.215 0.022 14000.0 0.305 29.698 2.584 948.650 0.098 0.010 3.262 0.618 0.230 0.025 14500.0 0.303 29.241 2.661 948.413 0.102 0.011 3.310 0.649 0.245 0.027 15000.0 0.302 28.788 2.737 948.177 0.107 0.012 3.354 0.679 0.259 0.030 15500.0 0.300 28.337 2.812 947.941 0.112 0.013 3.395 0.711 0.274 0.034 16000.0 0.299 27.890 2.887 947.706 0.117 0.014 3.433 0.742 0.289 0.037 16500.0 0.397 27.446 2.960 947.471 0.122 0.015 3.468 0.773 0.303 0.040 17000.0 0.296 27.004 3.033 947.236 0.127 0.016 3.501 0.804 0.318 0.044 17500.0 0.294 26.566 3.105 947.000 0.132 0.017 3.531 0.835 0.333 0.048 18000.0 0.292 26.131 3.176 946.765 0.137 0.018 3.559 0.866 0.347 0.052 18500.0 0.291 25.699 3.247 946.528 0.142 0.019 3.585 0.897 0.362 0.056 19000.0 0.289 25.270 3.317 946.291 0.148 0.021 3.610 0.928 0.371 0.060 19500.0 0.288 24.844 3.386 946.052 0.153 0.022 3.632 0.959 0.392 0.065 20000.0 0.286 24.422 3.454 945.813 0.158 0.023 3.654 0.990 0.407 0.070 22500.0 0.278 22.358 3.785 944.593 0.185 0.031 3.740 1.142 0.481 0.097 25000.0 0.270 20.377 4.096 943.337 0.214 0.040 3.795 1.290 0.555 0.130 27500.0 0.262 18.450 4.389 942.040 0.244 0.050 3.824 1.434 0.625 0.168 30000.0 0.254 15.668 4.663 940.701 0.276 0.062 3.830 1.573 0.690 0.212 32500.0 0.246 14.944 4.917 939.314 0.308 0.076 3.818 1.705 0.751 0.262 35000.0 0.238 13.309 5.152 937.678 0.340 0.091 3.789 1.831 0.805 0.319 37500.0 0.230 11.767 5.366 936.387 0.373 0.108 3.748 1.950 0.553 0.381 40000.0 0.222 10.320 5.560 934.837 0.406 0.126 3.697 2.061 0.895 0.450 42500.0 0.214 6.971 5.734 933.223 0.438 0.145 3.638 2.163 0.929 0.525 45000.0 0.205 7.725 5.685 931.540 0.470 0.166 3.574 2.255 0.958 0.605 47500.0 0.197 6.584 6.015 929.786 0.502 0.188 3.508 2.339 0.980 0.691 50000.0 0.189 5.551 6.123 927.955 0.532 0.210 3.440 2.412 0.997 0.783 52500.0 0.180 4.626 6.209 926.044 0.561 0.232 3.375 2.476 1.008 0.579 55000.0 0.172 3.910 6.273 924.052 0.588 0.255 3.312 2.529 1.015 0.980 57500.0 0.163 3.101 6.316 921.979 0.613 0.277 3.253 2.574 1.019 1.065 60000.0 0.155 2.494 6.339 919.827 0.636 0.297 3.199 2.609 1.019 1.192 62500.0 0.147 1.964 6.343 917.599 0.657 0.317 3.151 2.637 1.017 1.302 65000.0 0.139 1.563 6.330 915.301 0.676 0.335 3.108 2.657 1.014 1.412 67500.0 0.132 1.220 6.302 912.941 0.692 0.352 3.072 2.671 1.009 1.523 70000.0 0.124 0.945 6.262 910.526 0.706 0.367 3.040 2.680 1.004 1.633 AREVA Inc.
Contro ed Document Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page C-27 Table C.26 [ ] Exposure-Dependent 40% Void Isotopics (kg/MTU Initial)
Exposure MWd/14TU 0-234 0-235 U-236 U-238 NP-237 P0-238 P0-239 PU-240 P0-241 P0-242 0.0 0.354 44.251 0.000 955.395 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.354 44.131 0.023 955.339 0.000 0.000 0.020 0.000 0.000 0.000 500.0 0.352 43.655 0.115 955.116 0.002 0.000 0.199 0.001 0.000 0.000 1000.0 0.350 43.068 0.227 954.837 0.004 0.000 0.430 0.007 0.000 0.000 1500.0 0.348 42.489 0.339 954.558 0.006 0.000 0.650 0.015 0.001 0.000 2000.0 0.346 41.918 0.447 954.279 0.009 0.000 0.858 0.027 0.003 0.000 2500.0 0.344 41.356 0.554 954.000 0.012 0.000 1.058 0.041 0.005 0.000 3000.0 0.341 40.800 0.659 953.722 0.015 0.000 1.249 0.057 0.008 0.000 2500.0 0.339 40.252 0.763 953.444 0.016 0.001 1.431 0.075 0.012 0.000 4000.0 0.337 39.711 0.865 953.166 0.021 0.051 1.604 0.085 0.017 0.000 4500.0 0.335 39.176 0.965 952.689 0.025 0.001 1.769 0.116 0.024 0.001 5000.0 0.333 38.647 1.064 952.612 0.028 0.001 1.927 0.139 0.031 0.001 5500.0 0.331 38.125 1.162 952.335 0.032 0.002 2.077 0.162 0.039 0.001 6000.0 0.329 37.608 1.258 952.059 0.036 0.002 2.220 0.187 0.048 0.002 6500.0 0.327 37.098 1.353 951.782 0.040 0.002 2.356 0.213 0.058 0.002 7000.0 0.326 36.592 1.446 951.507 0.045 0.003 2.486 0.240 0.069 0.003 7500.0 0.324 36.092 1.538 951.231 0.049 0.003 2.610 0.267 0.081 0.004 8000.0 0.322 35,597 1.629 950.556 0.054 0.004 2.727 0.285 0.093 0.005 8500.0 0.320 35.108 1.718 950.682 0.058 0.004 2.839 0.324 0.107 0.006 9000.0 0.318 24.623 1.807 950.406 0.063 0.005 2.946 0.353 0.120 0.007 9500.0 0.316 34.143 1.894 950.134 0.068 0.005 3.047 0.382 0.135 0.008 10000.0 0.314 33.667 1.980 949.961 0.073 0.006 3.142 0.412 0.150 0.010 10500.0 0.312 33.186 2.064 949.589 0.078 0.007 3.233 0.443 0.165 0.012 11000.0 0.310 32.729 2.148 949.317 0.084 0.008 3.319 0.474 0.181 0.014 11500.0 0.309 32.267 2.230 949.045 0.089 0.009 3.400 0.505 0.197 0.016 12000.0 0.307 31.808 2.312 948.774 0.095 0.009 3,477 0.537 0.213 0.018 12500.0 0.305 31.354 2.392 948.504 0.100 0.010 3.550 0.569 0.230 0.021 13000.0 0.303 30.903 2.471 948.234 0.106 0.011 3.618 0.601 0.247 0.023 13500.0 0.301 30.456 2.550 947.965 0.111 0.012 3.682 0.633 0.264 0.026 14000.0 0.300 30.013 2.627 947.696 0.117 0.013 3.742 0.665 0.281 0.029 14500.0 0.298 29.574 2.703 947.428 0.123 0.015 3.799 0.698 0.299 0.032 15000.0 0.296 29.138 2.779 947.161 0.128 0.016 3.851 0.731 0.316 0.036 15500.0 0.294 28.705 2.854 946.894 0.134 0.017 3.900 0.763 0.333 0.039 16000.0 0.293 28.275 2.927 948.629 0.140 0.018 3.946 0.796 0.350 0.043 16500.0 0.291 27.849 3.000 946.363 0.146 0.020 3.989 0.829 0.368 0.047 17000.0 0.289 27.426 3.072 946.098 0.151 0.021 4.029 0.862 0.385 0.051 17500.0 0.288 27.006 3.143 945.832 0.157 0.022 4.066 0.895 0.402 0.055 18000.0 0.286 26.589 3.213 945.567 0.163 0.024 4.101 0.928 0.419 0.060 18500.0 0.284 26.176 3.283 945.301 0.169 0.026 4.133 0.961 0.437 0.064 19000.0 0.283 25.765 3.352 945.035 0.175 0.027 4.184 0.983 0.454 0.069 19500.0 0.281 25.358 3.420 944.768 0.181 0.028 4.193 1.026 0.471 0.074 20000.0 0.279 24.954 3.487 944.498 0.188 0.031 4.219 1.059 0.488 0.079 20500.0 0.278 24.554 3.553 944.230 0.194 0.032 4.244 1.091 0.505 0.085 21000.0 0.276 24.156 3.619 943.960 0.200 0.034 4.268 1.123 0.522 0.091 22500.0 0.271 22.984 3.810 943.141 0.219 0.040 4.331 1.219 0.573 0.109 25000.0 0.263 21.097 4.114 941.749 0.252 0.051 4.409 1.374 0.658 0.144 27500.0 0.255 19.294 4.398 940.320 0.287 0.065 4.460 1.524 0.739 0.184 30000.0 0.247 17.573 4.663 938.854 0.322 0.080 4.485 1.669 0.815 0.228 32500.0 0.238 15.937 4.908 937.346 0.358 0.096 4.490 1.807 0.886 0.280 35000.0 0.230 14.384 5.134 935.797 0.393 0.115 4.477 1.939 0.950 0.337 37500.0 0.222 12.917 5.341 934.201 0.429 0.136 4.448 2.063 1.008 0.399 40000.0 0.214 11.536 5.528 932.558 0.465 0.158 4.408 2.179 1.059 0.465 42500.0 0.206 10.242 5.696 930.865 0.500 0.181 4.358 2.287 1.103 0.537 45000.0 0.298 9.035 5.845 929.119 0.535 0.208 4.300 2.287 1.140 0.613 47500.0 0.191 7.918 5,974 927.318 0.589 0.232 4.237 2.477 1.171 0.694 50000.0 0.183 6.889 6.083 925.459 0.601 0.259 4.170 2.558 1.196 0.778 52500.0 0.175 5.951 6.174 923.541 0.632 0.286 4.103 2.629 1.215 0.868 55000.0 0.168 5.101 6.245 921.563 0.662 0.313 4.035 2.892 1.228 0.880 57500.0 0.160 4.338 6.298 919.523 0.689 0.340 3.968 2.745 1.238 1.054 60000.0 0.153 3.661 6.333 917.423 0.715 0.367 3.905 2.790 1.243 1.151 62500.0 0.146 3.066 8.352 915.264 0.739 0.392 3.845 2.827 1.244 1.250 65000.0 0.139 2.549 8.354 913.047 0.760 0.416 3.790 2.857 1.243 1.350 67500.0 0.132 2.104 6.342 910.777 0.780 0.438 3.738 2.879 1.240 1.451 70000.0 0.126 1.725 6.317 908.457 0.796 0.460 3.692 2.896 1.236 1.551 AREVA Inc.
Controiled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page C-28 Table C.27 [ J Exposure-Dependent 80% Void Isotopics (kgIMTU Initial)
Exposure MWd/M4TU U-234 0-235 0-236 0-238 52-237 P0-238 P0-239 P0-240 PU-241 PU-242 0.0 0.354 44.251 0.000 955.395 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.354 44.132 0.024 955.329 0.000 0.000 0.023 0.000 0.000 0.000 500.0 0.351 43.659 0.121 955.064 0.002 0.000 0.234 0.002 0.000 0.000 1000.0 0.349 43.077 0.239 954.733 0.005 0.000 0.504 0.009 0.000 0.000 1500.0 0.347 42.505 0.355 954.403 0.008 0.000 0.762 0.019 0.002 0.000 2000.0 0.344 41.942 0.469 954.074 0.011 0.000 1.007 0.031 0.004 0.000 2500.0 0.342 41.388 0.581 952.745 0.014 0.000 1.241 0.046 0.007 0.000 3000.0 0.339 40.942 0.691 953.416 0.018 0.001 1.464 0.064 0.011 0.000 3500.0 0.337 40.305 0.799 953.088 0.022 0.001 1.678 0.084 0.017 0.000 4000.0 0.335 39.775 0.905 952.761 0.026 0.001 1.881 0.106 0.024 0.001 4500.0 0.332 39.252 1.009 952.434 0.031 0.001 2.076 0.129 0.032 0.001 5000.0 0.330 38.737 1.111 952.108 0.035 0.002 2.262 0.154 0.041 0.001 5500.0 0.328 38.228 1.212 951.782 0.040 0.002 2.439 0.179 0.052 0.002 6000.0 0.325 37.726 1.311 951.457 0.045 0.003 2.609 0.206 0.064 0.002 6500.0 0.323 37.229 1.408 951.132 0.051 0.003 2.771 0.234 0.077 0.003 7000.0 0.321 36.739 1.504 950.808 0.056 0.004 2.926 0.262 0.090 0.004 7600.0 0.319 36.255 1.598 950.485 0.062 0.005 3.074 0.291 0.105 0.005 8000.0 0.316 35.777 1.691 950.162 0.068 0.005 3.216 0.321 0.120 0.006 8600.0 0.314 35.304 1.793 949.840 0.074 0.006 3.351 0.352 0.137 0.007 9000.0 0.312 34.836 1.873 949.519 0.080 0.007 3.479 0.383 0.153 0.009 9600.0 0.310 34.373 1.961 949.198 0.086 0.008 3.602 0.415 0.171 0.011 10000.0 0.308 33.916 2.049 948.877 0.092 0.009 3.719 0.447 0.189 0.012 10500.0 0.306 33.463 2.135 948.558 0.099 0.010 3.831 0.479 0.207 0.014 11000.0 0.304 33.015 2.220 948.239 0.105 0.011 3.937 0.512 0.226 0.017 11500.0 0.302 32.672 2.303 947.921 0.112 0.012 4.038 0.546 0.246 0.019 12000.0 0.300 32.133 2.386 947.603 0.118 0.014 4.135 0.880 0.265 0.021 12500.0 0.298 31.698 2.467 947.286 0.125 0.015 4.226 0.814 0.285 0.024 13000.0 0.296 31.268 2.547 946.970 0.132 0.017 4.312 0.648 0.305 0.027 13500.0 0.294 30.842 2.626 946.655 0.139 0.018 4.396 0.683 0.326 0.030 14000.0 0.292 30.420 2.703 946.340 0.148 0.020 4.472 0.718 0.346 0.033 14500.0 0.290 30.001 2.780 946.026 0.153 0.021 4.546 0.753 0.366 0.037 15000.0 0.288 29.587 2.855 945.713 0.160 0.023 4.615 0.788 0.387 0.041 15500.0 0.286 29.176 2.930 945.401 0.167 0.025 4.681 0.823 0.407 0.044 16000.0 0.284 28.769 3.004 945.089 0.174 0.027 4.743 0.659 0.428 0.048 16500.0 0.262 28.386 3.076 944.778 0.181 0.028 4.801 0.894 0.448 0.053 17000.0 0.280 27.965 2.148 944.468 0.188 0.030 4.856 0.930 0.469 0.057 17500.0 0.278 27.569 3.219 944.157 0.195 0.033 4.908 0.966 0.489 0.082 18000.0 0.276 27.178 3.288 943.648 0.203 0.035 4.957 1.001 0.509 0.068 18500.0 0.275 26.785 3.356 943.538 0.210 0.037 5.003 1.037 0.530 0.071 19000.0 0.273 26.398 3.424 943.228 0.217 0.039 5.047 1.073 0.550 0.076 19500.0 0.271 26.015 3.491 942.917 0.224 0.042 5.088 1.108 0.570 0.082 20000.0 0.269 25.835 3.557 942.606 0.232 0.044 5.127 1.144 0.590 0.087 20500.0 0.267 25.258 3.823 942.295 0.239 0.048 5.164 1.179 0.610 0.093 21000.0 0.268 24.885 3.887 941.982 0.247 0.049 5.200 1.214 0.630 0.099 21500.0 0.284 24.514 3.750 941.689 0.254 0.052 5.233 1.249 0.649 0.105 22000.0 0.282 24.147 3.913 941.355 0.262 0.055 5.265 1.284 0.889 0.111 22500.0 0.260 23.784 3.875 941.040 0.269 0.057 5.295 1.319 0.689 0.118 22000.0 0.259 23.424 3.938 940.724 0.277 0.060 5.324 1.354 0.709 0.124 25000.0 0.252 22.015 4.172 939.446 0.307 0.073 5.426 1.490 0.787 0.153 27500.0 0.243 20.329 4.449 937.819 0.347 0.091 5.525 1.856 0.883 0.193 30000.0 0.235 18.724 4.706 938.159 0.388 0.111 5.597 1.816 0.974 0.237 32500.0 0.226 17.198 4.943 934.464 0.426 0.133 5.645 1.970 1.061 0.286 35000.0 0.218 15.751 5.161 932.735 0.488 0.157 5.673 2.118 1.141 0.339 37500.0 0.210 14.383 5.380 930.969 0.508 0.184 5.682 2.258 1.216 0.397 40000.0 0.202 13.092 8.540 929.188 0.545 0.212 5.878 2.392 1.285 0.458 42500.0 0.195 11.877 5.702 927.326 0.584 0.243 5.657 2.518 1.347 0.523 45000.0 0.187 10.738 5.845 925.446 0.622 0.275 5.627 2.636 1.402 0.592 47500.0 0.180 9.674 5.970 923.528 0.658 0.308 "5.588 2.745 1.452 0.884 50000.0 0.173 8.883 8.079 921.587 0.694 0.343 5.542 2.646 1.495 0.739 52500.0 0.166 7.764 6.170 919.568 0.728 0.378 5.491 2.939 1.532 0.817 55000.0 0.159 6.915 6.245 917.528 0.761 0.414 5.436 3.024 1.564 0.897 57500.0 0.153 6.135 6.305 915.448 0.791 0.450 5.378 3.100 1.590 0.979 60000.0 0.146 5.422 6.349 913.328 0.820 0.486 5.320 3.188 1.812 1.064 62500.0 0.140 4.773 8.379 911.169 0.947 0.521 5.281 3.229 1.629 1.150 65000.0 0.134 4.185 6.395 908.972 0.971 0.6586 5.203 3.282 1.843 1.237 67500.0 0.129 3.656 8.398 908.738 0.994 0.590 5.146 3.327 1.653 1.326 70000.0 0.123 3.183 6.389 904.489 0.914 0.822 5.092 3.387 1.659 1.416 AREVA Inc.
Controlled Docurnent Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page C-29 Table C.28 [ ] Exposure-Dependent 0% Void Isotopics (kgIMTU Initial)
Exposure lIWd/MTU U-234 U-235 U-236 0-238 NP-237 PU-238 P0-239 P0-240 P0-241 PU-242 0.0 0.354 44.250 0.000 955.396 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.354 44.130 0.022 955.348 0.000 0.000 0.017 0.000 0.000 0.000 500.0 0.352 43.652 0.110 955.156 0.001 0.000 0.173 0.001 0.000 0.000 1000.0 0.350 43.061 0.219 954.915 0.003 0.000 0.373 0.006 0.000 0.000 1500.0 0.348 42.478 0.325 954.675 0.005 0.000 0.583 0.013 0.001 0.000 2000.0 0.347 41.902 0.431 954.435 0.007 0.000 0.745 0.023 0.002 0.000 2500.0 0.345 41.333 0.534 954.195 0.009 0.000 0.918 0.036 0.004 0.000 3000.0 0.343 40.771 0.636 953.955 0.012 0.000 1.083 0.050 0.006 0.000 3500.0 0.341 40.214 0.737 953.716 0.015 0.000 1.239 0.087 0.009 0.000 4000.0 0.339 39.654 0.536 953.477 0.017 0.001 1.389 0.084 0.013 0.000 4500.0 0.338 39.119 0.934 953.238 0.020 0.001 1.531 0.104 0.018 0.001 5000.0 0.335 38.580 1.031 953.000 0.023 0.001 1.866 0.124 0.023 0.001 5600.0 0.334 38.047 1.127 952.783 0.026 0.001 1.794 0.148 0.030 0.001 6000.0 0.332 37.518 1.221 952.525 0.030 0.001 1.917 0.169 0.037 0.001 6500.0 0.331 36.995 1.314 952.289 0.033 0.002 2.033 0.193 0.044 0.002 7000.0 0.329 36.476 1.406 952.053 0.037 0.002 2.143 0.217 0.053 0.002 7500.0 0.327 35.962 1.496 951.817 0.040 0.002 2.247 0.242 0.062 0.003 8000.0 0.326 35.453 1.586 951.562 0.044 0.003 2.346 0.268 0.072 0.004 8500.0 0.324 34.948 1.674 951.347 0.048 0.003 2.440 0.295 0.082 0.005 9000.0 0.322 34.447 1.782 951.114 0.051 0.004 2.529 0.322 0.093 0.006 9500.0 0.320 33.950 1.848 950.880 0.055 0.004 2.513 0.350 0.104 0.007 10000.0 0.319 33.457 1.934 950.648 0.059 0.004 2.692 0.378 0.116 0.008 10500.0 0.317 32.968 2.018 950.415 0.063 0.005 2.766 0.406 0.129 0.010 11000.0 0.316 32.483 2.101 950.185 0.068 0.006 2.636 0.435 0.141 0.011 11500.0 0.314 32.001 2.184 949.955 0.072 0.006 2.902 0.464 0.153 0.013 12000.0 0.312 31.523 2.265 949.726 0.076 0.007 2.964 0.493 0.166 0.015 12500.0 0.311 31.048 2.346 949.497 0.080 0.007 3.022 0.523 0.180 0.017 13000.0 0.309 30.576 2.425 949.269 0.085 0.008 3.076 0.552 0.193 0.019 13500.0 0.308 30.108 2.504 949.040 0.089 0.009 3.128 0.582 0.207 0.021 14000.0 0.306 29.643 2.582 948.812 0.094 0.010 3.176 0.612 0.220 0.024 14500.0 0.304 29.181 2.859 948.584 0.099 0.010 3.221 0.643 0.234 0.026 15000.0 0.303 28.723 2.736 948.355 0.103 0.011 3.264 0.673 0.248 0.029 15500.0 0.301 28.267 2.811 948.126 0.108 0.012 3.305 0.703 0.262 0.032 16000.0 0.300 27.815 2.888 947.895 0.113 0.013 3.343 0.733 0.277 0.035 16500.0 0.298 27.367 2.960 947.664 0.118 0.014 3.379 0.754 0.291 0.038 17000.0 0.297 26.922 3.033 947.431 0.123 0.015 3.414 0.794 0.306 0.042 17500.0 0.295 26.480 3.106 947.198 0.128 0.016 3.446 0.824 0.320 0.046 20000.0 0.287 24.323 3.457 946.009 0.154 0.022 3.583 0.976 0.396 0.067 22500.0 0.279 22.250 3.789 944.786 0.182 0.030 3.682 1.125 0.471 0.094 25000.0 0.271 20.263 4.101 943.525 0.211 0.038 3.748 1.273 0.545 0.126 27500.0 0.263 18.361 4.394 942.224 0.241 0.049 3.786 1.416 0.616 0.164 30000.0 0.255 18.547 4.868 940.879 0.273 0.081 3.799 1.555 0.682 0.208 32500.0 0.247 14.822 4.922 939.488 0.305 0.074 3.792 1.589 0.742 0.258 35000.0 0.239 13.188 5.156 938.046 0.337 0.089 3.788 1.818 0.797 0.314 37500.0 0.231 11.647 5.370 936.548 0.371 0.108 3.730 1.938 0.845 0.377 40000.0 0.222 10.203 5.563 934.991 0.404 0.124 3.581 2.048 0.987 0.445 42500.0 0.214 8.860 5.735 933.370 0.436 0.144 3.824 2.151 0.923 0.520 45000.0 0.208 7.619 5.888 931.880 0.489 0.165 3.562 2.245 0.951 0.601 47500.0 0.197 6.485 8.014 929.918 0.500 0.187 3.497 2.330 0.974 0.587 50000.0 0.189 5.459 6.121 928.078 0.531 0.209 3.431 2.405 0.991 0.779 52500.0 0.180 4.543 8.205 926.156 0.580 0.231 3.366 2.489 1.003 0.878 55000.0 0.172 3.736 6.267 924.154 0.587 0.254 3.304 2.524 1.011 0.977 57500.0 0.183 3.036 6.308 922.072 0.812 0.278 3.246 2.589 1.014 1.081 50000.0 0.155 2.438 6.329 919.910 0.836 0.297 3.193 2.605 1.015 1.189 82500.0 0.147 1.937 8.332 917.873 0.658 0.317 3.146 2.833 1.014 1.299 65000.0 0.139 1.524 8.317 915.358 0.875 0.335 3.104 2.854 1.011 1.409 87500.0 0.131 1.188 8.288 912.998 0.891 0.351 3.068 2.889 1.007 1.520 70000.0 0.124 0.920 6.247 910.577 0.705 0.388 3.037 2.678 1.002 1.630 AREVA Inc.
Controfled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page C-30 Table C.29 [ J Exposure-Dependent 40% Void Isotopics (kgIMTU Initial)
Exposure MWd/MTUft 0-234 0-235 0-236 0-238 N4P-237 P0-238 PU-239 P0-240 PU-241 P0-242 0.0 0.354 44.250 0.000 955.396 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.354 44.130 0.023 955.341 0.000 0.000 0.020 0.000 0.000 0.000 500.0 0.352 43.654 0.114 955.119 0.002 0.000 0.198 0.001 0.000 0.000 1000.0 0.350 43.066 0.227 954.842 0.004 0.000 0.426 0.007 0.000 0.000 1500.0 0.348 42.487 0.338 954.568 0.006 0.000 0.644 0.015 0.001 0.000 2000.0 0.346 41.916 0.446 954.250 0.009 0.000 0.651 0.027 0.003 0.000 2500.0 0.344 41.353 0.553 954.015 0.011 0.000 1.048 0.041 0.005 0.000 3000.0 "0.342 40.796 0.658 553.741 0.014 0.000 1.235 0.057 0.008 0.000 3500.0 0.340 40.249 0.762 953.467 0.017 0.001 1.414 0.075 0.012 0.000 4000.0 0.336 39.707 0.664 953.193 0.021 0.001 1.553 0.095 0.017 0.000 4500.0 0.336 39.171 0.964 952.921 0.024 0.001 1.745 0.116 0.023 0.001 5000.0 0.334 38.642 1.063 952.649 0.028 0.001 1.859 0.138 0.030 0.001 5500.0 0.332 38.118 1.160 952.377 0.032 0.002 2.045 0.162 0.038 0.001 6000.0 0.330 37.601 1.256 952.106 0.036 0.002 2.184 0.187 0.047 0.002 6500.0 0.328 37.089 1.350 951.837 0.040 0.002 2.316 0.212 0.057 0.002 7000.0 0.326 36.582 1.444 951.567 0.044 0.003 2.442 0.239 0.068 0.003 7500.0 0.324 36.060 1.536 851.299 0.048 0.003 2.561 0.266 0.079 0.004 8000.0 0.322 35.583 1.626 851.031 0.052 0.004 2.674 0.294 0.091 0.005 6500.0 0.320 35.091 1.715 950.764 0.057 0.004 2.782 0.322 0.104 0.006 9000.0 0.318 34.604 1.803 950.498 0.082 0.005 2.883 0.351 0.117 0.007 9500.0 0.317 34.121 1.890 950.233 0.066 0.005 2.979 0.381 0.131 0.009 10000.0 0.315 33.643 1.976 849.969 0.071 0.006 3.070 0.411 0.145 0.010 00500.0 0.313 33.169 2.061 549.706 0.076 0.007 3.156 0.441 0.160 0.012 11000.0 0.311 32.698 2.144 949.444 0.081 0.007 3.237 0.472 0.175 0.014 11500.0 0.309 32.232 2.227 949.182 0.086 0.008 3.314 0.503 0.190 0.016 12000.0 0.308 31.770 2.308 948.922 0.092 0.009 3.386 0.534 0.206 0.018 12500.0 0.306 31.311 2.388 948.662 0.097 0.010 3.454 0.565 0.222 0.020 13000.0 0.304 30.866 2.468 948.403 0.102 0.011 3.517 0.597 0.238 0.022 13500.0 0.302 30.404 2.546 948.144 0.107 0.012 3.577 0.629 0.254 0.025 14000.0 0.301 29.955 2.624 847.886 0.113 0.013 3.634 0.661 0.270 0.028 14500.0 0.299 29.510 2.700 547.628 0.118 0.014 3.688 0.692 0.286 0.031 15000.0 0.297 29.069 2.776 947.369 0.124 0.015 3.739 0.724 0.303 0.034 15500.0 0.296 28.631 2.851 947.110 0.129 0.016 3.787 0.757 0.319 0.038 16000.0 0.294 28.197 2.825 946.851 0.135 0.027 3.832 0.789 0.336 0.041 16500.0 0.292 27.766 2.988 946.590 0.141 0.019 3.876 0.821 0.353 0.045 17000.0 0.291 27.338 3.071 946.329 0.146 0.020 3.917 0.853 0.370 0.048 17500.0 0.288 26.514 3.142 946.067 0.152 0.021 3.956 0.885 0.387 0.053 18000.0 0.287 26.494 3.213 845.803 0.158 0.023 3.953 0.917 0.404 0.057 20000.0 0.280 24.846 3.488 844.727 0.182 0.029 4.124 1.044 0.474 0.077 22500.0 0.272 22.866 3.813 943.374 0.214 0.039 4.251 1.201 0.561 0.105 25000.0 0.264 20.971 4.118 941.976 0.248 0.050 4.343 1.354 0.646 0.140 27500.0 0.256 19.161 4.403 940.543 0.283 0.063 4.404 1.504 0.727 0.180 30000.0 0.247 17.438 4.667 939.070 0.318 0.078 4.438 1.649 0.804 0.225 32500.0 0.239 15.799 4.913 937.558 0.354 0.095 4.450 1.788 0.874 0.276 35000.0 0.231 14.247 5.138 936.001 0.390 0.113 4.442 1.920 0.939 0.332 37500.0 0.223 12.781 5.344 934.400 0.427 0.134 4.419 2.046 0.997 0.394 40000.0 0.215 11.402 5.531 932.750 0.463 0.156 4.382 2.163 1.049 0.461 42500.0 0.207 10.111 5.697 931.049 0.498 0.179 4.335 2.272 1.093 0.532 45000.0 0.199 8.910 5.645 929.295 0.533 0.204 4.279 2.373 1.131 0.609 47500.0 0.191 7.798 5.972 927.486 0.567 0.230 4.218 2.464 1.162 0.690 50000.0 0.183 6.777 6.080 925.618 0.599 0.257 4.154 2.546 1.187 0.775 52500.0 0.175 5.846 6.169 923.690 0.631 0.284 4.087 2.619 1.207 0.863 55000.0 0.168 5.004 6.238 921.702 0.660 0.312 4.021 2.683 1.221 0.9555 57500.0 0.160 4.250 6.290 919.653 0.688 0.339 3.956 2.736 1.231 1.050 60000.0 0.153 3.562 6.323 917.543 0.714 0.365 3.694 2.763 1.236 1.148 62500.0 0.146 2.996 6.340 915.374 0.737 0.391 3.835 2.821 1.238 1.247 65000.0 0.139 2.487 6.341 813.148 0.759 0.415 3.780 2.851 1.238 1.347 67500.0 0.132 2.050 6.327 910.568 0.776 0.438 3.730 2.870 1.235 1.448 70000.0 0.126 1.680 6.300 908.540 0.795 0.459 3.685 2.892 1.231 1.548 AREVA Inc.
Controlled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page C-31 Table C.30 [ JExposure-Dependent 80% Void Isotopics (kg/MTU Initial)
Exposure M~d/MTU 0-234 U-235 U-236 U-238 NP-237 P0-238 P0-239 P0-240 P0-241 PU-242 0.0 0.354 44.250 0.000 955.396 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.354 44.131 0.024 955.331 0.000 0.000 0.023 0.000 0.000 0.000 500.0 0.351 43.655 0.121 955.069 0.002 0.000 0.232 0.002 0.000 0.000 1000.0 0.349 43.075 0.239 554.741 0.005 0.000 0.499 0.008 0.000 0.000 1500.0 0.347 42.503 0.355 954.415 0.008 0.000 0.753 0.019 0.002 0.000 2000.0 0.344 41.940 0.468 954.090 0.011 0.000 0.995 0.031 0.004 0.000 2500.0 0.342 41.385 0.580 953.765 0.014 0.000 1.225 0.049 0.007 0.000 3000.0 0.339 40.839 0.699 953.442 0.018 0.001 2.445 0.064 0.011 0.000 3500.0 0.337 40.301 0.797 953.119 0.022 0.001 1.954 0.094 0.017 0.000 4000.0 0.335 39.771 0.903 952.797 0.026 0.001 1.953 0.106 0.024 0.001 4500.0 0.332 39.247 1.006 952.476 0.030 0.001 2.043 0.129 0.032 0.001 5000.0 0.330 38.731 1.108 952.156 0.035 0.002 2.224 0.153 0.041 0.001 5500.0 0.328 39.221 1.209 951.837 0.040 0.002 2.396 0.179 0.051 0.002 6000.0 0.326 37.718 1.308 951.519 0.045 0.003 2.561 0.206 0.063 0.002 6500.0 0.323 37.220 1.405 951.201 0.050 0.003 2.718 0.233 0.075 0.003 7000.0 0.321 36.729 1.500 950.985 0.055 0.004 2.968 0.262 0.089 0.004 7500.0 0.319 36.243 1.594 950.570 0.061 0.005 3.010 0.291 0.103 0.005 9000.0 0.317 35.763 1.687 950.255 0.066 0.005 3.146 0.321 0.118 0.006 8500.0 0.315 35.287 1.778 949.942 0.072 0.006 3.275 0.351 0.134 0.007 9000.0 0.313 34.818 1.868 949.629 0.078 0.007 3.398 0.382 0.150 0.009 9500.0 0.311 34.353 1.956 949.318 0.084 0.009 3.515 0.414 0.167 0.010 10000.0 0.309 33.992 2.043 949.007 0.090 0.009 3.626 0.446 0.284 0.012 10500.0 0.306 33.437 2.129 949.698 0.096 0.010 3.732 0.479 0.202 0.014 11000.0 0.304 32.965 2.214 949.390 0.102 0.011 3.832 0.512 0.220 0.016 11500.0 0.302 32.539 2.297 948.093 0.109 0.012 3.927 0.545 0.238 0.018 12000.0 0.300 32.096 2.379 947.776 0.115 0.013 4.018 0.578 0.257 0.021 12500.0 0.298 31.657 2.460 947.471 0.121 0.014 4.103 0.612 0.276 0.024 13000.0 0.297 31.223 2.540 947.167 0.129 0.016 4.184 0.646 0.295 0.026 13500.0 0.295 30.792 2.619 946.863 0.134 0.017 4.261 0.680 0.314 0.029 14000.0 0.293 30.365 2.697 946.560 0.141 0.019 4.335 0.715 0.334 0.032 14500.0 0.291 29.942 2.774 946.257 0.149 0.020 4.404 0.749 0.353 0.036 15000.0 0.299 29.522 2.950 945.954 0.154 0.022 4.470 0.794 0.373 0.039 15500.0 0.297 29.106 2.924 945.651 0.161 0.023 4.533 0.918 0.392 0.043 16000.0 0.295 28.694 2.998 945.348 0.168 0.025 4.593 0.953 0.412 0.047 16900.0 0.293 29.295 3.071 945.045 0.175 0.027 4.650 0.898 0.432 0.051 17000.0 0.291 27.990 3.143 944.741 0.192 0.029 4.705 0.923 0.452 0.055 17500.0 0.290 27.479 3.214 944.436 0.189 0.031 4.757 0.957 0.471 0.060 19000.0 0.279 27.090 3.284 944.130 0.196 0.033 4.907 0.992 0.491 0.064 19500.0 0.276 26.696 3.353 943.824 0.203 0.035 4.955 1.027 0.511 0.069 19000.0 0.274 26.295 3.421 943.516 0.211 0.037 4.901 1.061 0.531 0.074 19500.0 0.272 25.909 3.489 943.207 0.219 0.040 4.945 1.096 0.552 0.079 20000.0 0.271 25.524 3.555 942.998 0.225 0.042 4.997 1.131 0.572 0.085 22500.0 0.262 23.659 3.975 941.329 0.263 0.055 5.173 1.301 0.673 0.115 25000.0 0.253 21.880 4.173 939.729 0.302 0.070 5.320 1.469 0.772 0.149 27500.0 0.244 20.187 4.451 939.097 0.341 0.089 5.433 1.633 0.869 0.199 30000.0 0.236 18.576 4.709 936.430 0.391 0.109 5.517 1.792 0.960 0.233 32500.0 0.227 17.047 4.946 934.730 0.421 0.130 5.575 1.946 1.046 0.292 35000.0 0.219 15.598 5.163 932.994 0.462 0.155 5.611 2.094 1.127 0.335 37500.0 0.211 14.230 5.362 931.222 0.502 0.191 5.627 2.235 1.202 0.392 40000.0 0.203 12.940 5.541 929.412 0.541 0.210 5.627 2.369 1.270 0.454 42500.0 0.195 11.727 5.702 927.563 0.581 0.240 5.612 2.496 1.333 0.519 45000.0 0.199 10.592 5.844 925.676 0.619 0.272 5.596 2.615 1.399 0.597 47500.0 0.190 9.532 5.968 923.748 0.656 0.305 5.551 2.726 1.438 0.659 50000.0 0.173 9.546 6.075 921.791 0.692 0.340 5.508 2.929 1.482 0.734 52500.0 0.166 7.633 6.165 919.772 0.726 0.375 5.460 2.923 1.519 0.812 55000.0 0.159 6.791 6.239 917.724 0.759 0.411 5.407 3.006 1.552 0.892 57500.0 0.153 6.019 6.296 915.634 0.799 0.448 5.352 3.096 1.579 0.975 60000.0 0.146 5.312 6.339 913.505 0.819 0.494 5.295 3.155 1.601 1.059 62500.0 0.140 4.671 6.366 911.337 0.945 0.519 5.239 3.216 1.618 1.146 69000.0 0.134 4.091 6.391 909.131 0.869 0.554 5.192 3.270 1.632 1.234 67500.0 0.125 3.570 6.392 906.999 0.992 0.589 5.127 3.317 1.643 1.323 70000.0 0.123 3.104 6.372 904.610 0.912 0.620 5.074 3.357 1.650 1.412 AREVA Inc.
to: ile oetrn nt Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page C-32 Table C.31 [ ] Exposure-Dependent 0% Void Isotopics (kg/MTU Initial)
Exposure 145d/14TU 0-234 UJ-235 0-236 0-238 NP-237 20-238 PU-239 P0-240 P0-241 P0-242 0.0 0.362 45.231 0.000 954.407 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.361 45.111 0.023 954.356 0.000 0.000 0.020 0.000 0.000 0.000 500.0 0.360 44.633 0.112 954.151 0.002 0.000 0.189 0.001 0.000 0.000 1000.0 0.358 44.044 0.223 953.894 0.003 0.000 0.402 0.006 0.000 0.000 1500.0 0.356 43.462 0.332 953.636 0.005 0.000 0.605 0.014 0.001 0.000 2000.0 0.354 42.588 0.439 953.379 0.008 0.000 0.800 0.025 0.002 0.000 2500.0 0.392 42.320 0.545 953.121 0.010 0.000 0.986 0.038 0.004 0.000 3000.0 0.350 41.760 0.849 952.863 0.013 0.000 1.164 0.053 0.007 0.000 3500.0 0.348 41.207 0.752 952.604 0.016 0.000 1.334 0.010 0.010 0.000 4000.0 0.346 40.660 0.853 952.345 0.019 0.001 1.497 0.088 0.015 0.000 4500.0 0.344 40.119 0.953 992.086 0.022 0.001 1.653 0.109 0.020 0.001 5000.0 0.342 39.583 1.051 951.827 0.025 0.001 1.802 0.130 0.026 0.001 5500.0 0.340 39.064 1.149 951.568 0.029 0.001 1.944 0.152 0.034 0.001 6000.0 0.338 38.531 1.244 951.308 0.033 0.002 2.061 0.176 0.042 0.002 6500.0 0.337 38.013 1.339 951.048 0.036 0.002 2.211 0.200 0.050 0.002 7000.0 0.335 37.500 1.432 990.797 0.040 0.002 2.336 0.226 0.060 0.003 7500.0 0.333 36.992 1.524 950.527 0.045 0.003 2.455 0.252 0.071 0.004 8000.0 0.331 36.489 1.615 950.266 0.049 0.003 2.569 0.279 0.082 0.004 9500.0 0.329 35.991 1.705 950.005 0.053 0.004 2.678 0.306 0.094 0.006 9000.0 0.327 35.498 1.794 949.744 0.058 0.004 2.781 0.334 0.106 0.007 9500.0 0.325 35.010 1.982 949.483 0.062 0.005 2.881 0.362 0.119 0.008 10000.0 0.324 34.526 1.968 949.222 0.067 0.005 2.975 0.391 0.133 0.009 10500.0 0.322 34.046 2.053 948.960 0.072 0.006 3.065 0.420 0.147 0.011 11000.0 0.320 33.571 2.138 948.698 0.077 0.007 3.151 0.450 0.162 0.013 11500.0 0.318 33.100 2.221 948.437 0.062 0.007 3.233 0.480 0.177 0.015 12000.0 0.316 32.633 2.303 948.175 0.087 0.008 3.310 0.510 0.192 0.017 12500.0 0.315 32.171 2.385 947.913 0.092 0.009 3.384 0.541 0.208 0.019 13000.0 0.313 31.712 2.465 947.651 0.098 0.010 3.454 0.572 0.224 0.021 13600.0 0.311 31.257 2.544 947.389 0.103 0.011 3.520 0.503 0.240 0.024 14000.0 0.309 30.808 2.623 947.127 0.108 0.012 3.583 0.634 0.256 0.027 14500.0 0.307 30.359 2.700 946.865 0.114 0.013 3.642 0.665 0.273 0.030 15000.0 0.306 29.916 2.776 946.603 0.120 0.014 3.698 0.697 0.290 0.033 05500.0 0.304 29.476 2.852 946.341 0.125 0.015 3.751 0.728 0.306 0.036 16000.0 0.302 29.039 2.927 946.079 0.131 0.016 3.800 0.760 0.323 0.040 16500.0 0.301 28.606 3.000 945.818 0.137 0.018 3.846 0.792 0.340 0.044 17000.0 0.299 28.176 3.073 945.556 0.143 0.019 3.890 0.824 0.357 0.048 17500.0 0.297 27.750 3.145 946.295 0.148 0.020 3.931 0.656 0.374 0.052 18000.0 0.295 27.326 3.217 945.033 0.154 0.022 3.969 0.888 0.391 0.056 18500.0 0.294 26.906 3.267 944.771 0.160 0.023 4.004 0.920 0.408 0.061 19000.0 0.292 26.489 3.357 944.509 0.166 0.025 4.037 0.951 0.424 0.065 19500.0 0.290 26.076 3.426 944.247 0.172 0.026 4.058 0.983 0.441 0.070 20000.0 0.269 25.665 3.494 943.984 0.178 0.028 4.097 1.015 0.458 0.075 20500.0 0.287 25.258 3.561 943.720 0.184 0.030 4.124 1.047 0.474 0.081 21000.0 0.265 24.854 3.627 943.455 0.190 0.031 4.150 1.078 0.491 0.086 21500.0 0.284 24.453 3.693 943.189 0.197 0.033 4.174 1.109 0.508 0.092 22000.0 0.282 24.055 3.756 942.922 0.203 0.035 4.196 1.141 0.524 0.098 22500.0 0.280 23.661 3.822 942.663 0.209 0.037 4.217 1.172 0.541 0.104 25000.0 0.272 21.740 4.131 941.290 0.242 0.048 4.303 1.324 0.623 0.138 27500.0 0.264 19.902 4.420 939.890 0.275 0.060 4.360 1.471 0.703 0.177 30000.0 0.256 18.148 4.690 938.451 0.310 0.075 4.391 1.614 0.778 0.222 32500.0 0.247 16.477 4.941 936.971 0.346 0.091 4.401 1.750 0.948 0.272 35000.0 0.239 14.891 5.172 935.449 0.381 0.109 4.393 1.879 0.912 0.329 37500.0 0.231 13.390 5.384 933.881 0.417 0.129 4.369 2.002 0.969 0.389 40000.0 0.223 11.976 5.577 932.265 0.453 0.151 4.332 2.117 1.020 0.455 42500.0 0.215 10.648 5.750 930.598 0.489 0.174 4.286 2.223 1.065 0.526 45000.0 0.207 9.409 5.904 928.877 0.524 0.199 4.231 2.322 1.102 0.602 47500.0 0.199 8.260 6.038 927.101 0.558 0.226 4.170 2.411 1.134 0.683 50000.0 0.191 7.200 6.153 925.267 0.592 0.251 4.106 2.492 1.159 0.768 52500.0 0.183 6.231 6.249 923.372 0.623 0.278 4.040 2.564 1.179 0.656 55000.0 0.175 5.351 6.325 921.417 0.654 0.305 3.974 2.627 1.193 0.948 57500.0 0.166 4.660 6.383 919.400 0.682 0.332 3.908 2.681 1.203 1.043 60000.0 0.160 3.856 6.423 917.321 0.709 0.359 3.845 2.726 1.209 1.141 62900.0 0.153 3.235 6.446 915.181 0.734 0.384 3.786 2.764 1.211 1.240 65000.0 0.146 2.694 6.453 912.993 0.756 0.409 3.730 2.794 1.211 1.340 67500.0 0.139 2.227 6.444 910.729 0.776 0.431 3.679 2.818 1.209 1.442 70000.0 0.132 1.829 6.422 908.424 0.794 0.452 3.633 2.836 1.204 1.543 AREVA Inc.
Cortroiied Document Nuclear Fuel Design Report ANP-a294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page C-33 Table C.32 [ ] Exposure-Dependent 40% Void Isotopics (kg/MTU Initial)
Exposure tdWd/MTU1 U-234 U1-235 U1-236 U1-238 NP-237 PU1-238 PU1-239 PU1-240 PU1-241 PU1-242 0.0 0.362 45.231 0.000 954.407 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.361 45.112 0.023 954.349 0.000 0.000 0.023 0.000 0.000 0.000 500.0 0.360 44.636 0.117 954.115 0.002 0.000 0.214 0.002 0.000 0.000 1000.0 0.357 44.049 0.231 953.523 0.004 0.000 0.454 0.007 0.000 0.000 1500.0 0.355 43.471 0.344 953.530 0.006 0.000 0.594 0.016 0.001 0.000 2000.0 0.353 42.902 0.455 953.237 0.009 0.000 0.504 0.028 0.003 0.000 2500.0 0.351 42.341 0.564 952.944 0.012 0.000 1.114 0.042 0.005 0.000 3000.0 0.349 41.797 0.671 952.651 0.015 0.000 1.315 0.059 0.009 0.000 3500.0 0.346 41.241 0.776 952.358 0.019 0.001 1.507 0.077 0.013 0.000 4000.0 0.344 40.702 0.680 952.065 0.022 0.001 1.691 0.058 0.019 0.000 4500.0 0.342 40.170 0.992 951.771 0.026 0.001 1.967 0.119 0.026 0.001 5000.0 0.340 39.644 1.093 951.477 0.030 0.001 2.035 0.142 0.033 0.001 5500.0 0.338 39.125 1.182 951.193 0.034 0.002 2.197 0.167 0.042 0.002 6000.0 0.336 38.611 1.280 950.889 0.039 0.002 2.351 0.192 0.052 0.002 6500.0 0.334 38.104 1.377 950.594 0.043 0.003 2.500 0.218 0.063 0.003 7000.0 0.332 37.602 1.472 950.300 0.048 0.003 2.642 0.245 0.079 0.003 7500.0 0.329 37.106 1.565 950.005 0.053 0.004 2.777 0.273 0.087 0.004 8000.0 0.327 36.616 1.658 949.710 0.059 0.004 2.908 0.301 0.101 0.005 8500.0 0.325 36.130 1.749 549.416 0.063 0.005 3.032 0.330 0.115 0.007 9000.0 0.323 35.650 1.838 949.121 0.068 0.005 3.151 0.360 0.130 0.008 9500.0 0.321 35.175 1.927 948.825 0.074 0.006 3.265 0.390 0.145 0.009 10000.0 0.319 34.705 2.014 548.530 0.079 0.007 3.374 0.420 0.161 0.011 10500.0 0.317 34.239 2.100 948.235 0.095 0.008 3.478 0.451 0.179 0.013 11000.0 0.315 33.778 2.185 947.940 0.091 0.009 3.579 0.482 0.195 0.015 11500.0 0.313 33.322 2.268 947.649 0.097 0.010 3.673 0.514 0.212 0.017 12000.0 0.311 32.870 2.351 947.350 0.103 0.011 3.794 0.546 0.230 0.019 12500.0 0.309 32.423 2.432 947.054 0.109 0.012 3.850 0.578 0.249 0.022 13000.0 0.308 31.980 2.513 946.758 0.116 0.013 3.932 0.611 0.267 0.025 13500.0 0.306 31.541 2.592 946.464 0.122 0.014 4.011 0.643 0.286 0.028 14000.0 0.304 31.106 2.670 946.169 0.129 0.016 4.085 0.676 0.305 0.031 14500.0 0.302 30.675 2.748 945.874 0.135 0.017 4.156 0.709 0.324 0.034 15000.0 0.300 30.247 2.824 945.579 0.141 0.018 4.223 0.742 0.343 0.038 15600.0 0.298 29.824 2.899 949.284 0.148 0.020 4.287 0.776 0.363 0.041 16000.0 0.296 29.404 2.973 944.990 0.154 0.021 4.347 0.809 0.382 0.045 16500.0 0.294 28.989 3.047 944.695 0.161 0.023 4.404 0.843 0.402 0.049 17000.0 0.292 28.576 3.119 944.401 0.168 0.025 4.458 0.879 0.421 0.054 17500.0 0.291 28.167 3.191 944.107 0.174 0.026 4.509 0.910 0.440 0.058 18000.0 0.289 27.762 3.261 943.813 0.181 0.028 4.557 0.943 0.460 0.063 18500.0 0.287 27.359 3.331 943.519 0.188 0.030 4.602 0.977 0.479 0.088 19000.0 0.285 26.961 3.400 943.224 0.189 0.032 4.644 1.011 0.498 0.073 19500.0 0.283 26.569 3.468 942.930 0.202 0.034 4.684 1.044 0.518 0.078 20000.0 0.282 26.173 3.535 942.539 0.209 0.036 4.722 1.078 0.537 0.083 20500.0 0.280 25.784 3.601 942.340 0.216 0.038 4.757 1.111 0.556 0.089 21000.0 0.278 25.398 3.666 942.044 0.223 0.041 4.791 1.144 0.575 0.095 21900.0 0.276 25.015 3.731 941.748 0.230 0.043 4.823 1.178 0.594 0.101 22000.0 0.275 24.636 3.795 941.450 0.237 0.045 4.853 1.211 0.613 0.107 22500.0 0.273 24.260 3.858 941.151 0.244 0.048 4.881 1.243 0.631 0.113 23000.0 0.271 23.988 3.920 940.852 0.252 0.050 4.908 1.276 0.650 0.120 23500.0 0.269 23.518 3.981 940.551 0.259 0.053 4.934 1.309 0.669 0.127 24000.0 0.268 23.152 4.041 940.248 0.266 0.056 4.958 1.341 0.487 0.134 25000.0 0.264 22.431 4.160 939.640 0.281 0.061 5.002 1.405 0.724 0.149 27500.0 0.256 20.683 4.442 938.085 0.319 0.077 5.092 1.561 0.815 0.189 30000.0 0.247 19.018 4.705 936.516 0.358 0.095 5.154 1.711 0.901 0.234 32500.0 0.239 17.435 4.548 934.900 0.397 0.115 5.193 1.656 0.983 0.284 36000.0 0.230 15.932 5.172 533.246 0.436 0.137 5.212 1.994 1.059 0.339 37500.0 0.222 14.509 6.377 931.554 0.475 0.161 5.212 2.125 1.128 0.398 40000.0 0.214 13.164 5.563 929.822 0.514 0.188 5.198 2.249 1.191 0.462 42500.0 0.207 11.902 5.731 928.049 0.552 0.216 5.172 2.369 1.248 0.530 45000.0 0.199 10.716 5.880 926.234 0.589 0.245 5.135 2.473 1.297 0.602 47500.0 0.191 9.608 6.012 924.375 0.626 0.276 5.090 2.573 1.341 0.677 50000.0 0.184 8.577 6.126 922.471 0.661 0.308 5.038 2.665 1.378 0.755 52500.0 0.177 7.823 6.222 920.522 0.695 0.340 4.982 2.748 1.410 0.837 55000.0 0.170 6.744 9.302 918.528 0.727 0.373 4.923 2.824 1.436 0.921 57500.0 0.163 5.938 6.366 916.488 0.758 0.406 4.863 2.891 1.457 1.007 60000.0 0.156 5.204 6.413 914.403 0.787 0.439 4.801 2.950 1.473 1.095 62500.0 0.150 4.539 6.445 912.273 0.814 0.472 4.741 3.002 1.485 1.184 65000.0 0.144 3.941 6.463 910.099 0.839 0.503 4.682 3.047 1.493 1.275 67500.0 0.137 3.406 6.468 907.883 0.862 0.533 4.625 3.084 1.498 1.367 70000.0 0.132 2.931 6.459 905.627 0.883 0.562 4.571 3.116 1.500 1.459 AREVA Inc.
ControWled Dc irn I Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page C-34 Table C.33 [ ] Exposure-Dependent 80% Void Isotopics (kgIMTU Initial)
Exposure MO~d/MTU 0-234 U-235 U-236 0-238 NP-237 PU-238 PU-239 PU-240 PU-241 P0-242 0.0 0.382 45.231 0.000 954.407 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.351 45.112 0.025 954.340 0.000 0.000 0.026 0.000 0.000 0.000 500.0 0.359 44.640 0.122 954.069 0.002 0.000 0.245 0.002 0.000 0.000 1000.0 0.357 44.058 0.242 953.730 0.005 0.000 0.521 0.008 0.000 0.000 1500.0 0.354 43.487 0.360 953.391 0.008 0.000 0.784 0.018 0.002 0.000 2000.0 0.352 42.525 0.475 953.052 0.011 0.000 1.037 0.031 0.004 0.000 3500.0 0.349 42.372 0.588 952.713 0.015 0.000 1.278 0.047 0.007 0.000 3000.0 0.347 41.828 0.695 952.374 0.019 0.001 1.509 0.085 0.022 0.000 3500.0 0.344 41.292 0.809 952.035 0.023 0.001 1.730 0.085 0.017 0.000 4000.0 0.342 40.763 0.916 951.698 0.027 0.001 1.942 0.107 0.025 0.001 4500.0 0.339 40.241 1.022 951.357 0.032 0.002 2.146 0.130 0.033 0.001 5000.0 0.337 39.727 1.128 951.018 0.037 0.002 2.342 0.154 0.043 0.001 5500.0 0.334 39.220 1.228 950.679 0.042 0.002 2.530 0.180 0.053 0.002 6000.0 0.332 39.719 1.329 950.339 0.047 0.003 2.710 0.206 0.065 0.002 6500.0 0.330 39.224 1.428 950.000 0.053 0.004 2.884 0.234 0.078 0.003 7000.0 0.327 37.736 1.525 949.660 0.059 0.004 3.051 0.282 0.092 0.004 7500.0 0.326 37.254 1.621 949.320 0.065 0.005 3.211 0.292 0.107 0.005 8000.0 0.323 36.777 1.718 948.980 0.071 0.006 3.365 0.322 0.123 0.008 8500.0 0.320 36.306 1.809 948.641 0.077 0.007 3.513 0.352 0.140 0.008 9000.0 0.318 35.841 1.900 948.301 0.084 0.008 3.655 0.383 0.157 0.009 9500.0 0.316 35.381 1.991 947.961 0.091 0.009 3.792 0.415 0.175 0.011 10000.0 0.313 34.928 2.080 947.621 0.097 0.010 3.923 0.447 0.194 0.013 10500.0 0.311 34.476 2.167 947.281 0.104 0.011 4.049 0.480 0.213 0.015 11000.0 0.309 34.032 3.254 946.941 0.111 0.012 4.170 0.513 0.232 0.017 11500.0 0.307 33.592 2.339 946.602 0.118 0.014 4.287 0.546 0.252 0.019 12000.0 0.305 33.157 2.422 946.262 0.125 0.015 4.398 0.580 0.273 0.022 12500.0 0.302 32.726 2.505 945.922 0.133 0.017 4.506 0.614 0.293 0.024 13000.0 0.300 32.300 2.687 945.583 0.140 0.018 4.608 0.649 0.315 0.027 13500.0 0.298 31.878 2.667 945.243 0.148 0.020 4.707 0.683 0.338 0.030 14000.0 0.296 31.461 2.746 544.504 0.155 0.022 4.801 0.718 0.357 0.034 14500.0 0.294 31.048 2.824 544.664 0.163 0.024 4.892 0.754 0.379 0.037 15000.0 0.292 30.639 2.901 944.225 0.171 0.025 4.978 0.789 0.401 0.041 15500.0 0.290 30.234 2.976 943.888 0.178 0.028 5.061 0.825 0.423 0.045 16000.0 0.288 29.833 3.051 943.547 0.186 0.030 5.140 0.860 0.445 0.049 16500.0 0.288 29.436 3.124 943.208 0.194 0.032 5.218 0.898 0.467 0.053 17000.0 0.284 29.043 3.197 942.869 0.202 0.034 5.288 0.932 0.489 0.057 17500.0 0.282 28.654 3.269 942.531 0.210 0.037 5.357 0.969 0.511 0.062 18000.0 0.280 28.268 3.339 942.193 0.218 0.039 5.423 1.005 0.533 0.067 18500.0 0.278 27.888 3.409 941.854 0.226 0.042 5.485 1.041 0.555 0.071 19000.0 0.276 27.507 3.477 941.516 0.234 0.044 5.545 1.077 0.577 0.077 19500.0 0.274 27.132 3.545 941.178 0.242 0.047 5.602 1.114 0.598 0.082 20000.0 0.272 26.760 3.612 940.839 0.251 0.050 5.656 1.150 0.620 0.087 20500.0 0.270 26.391 3.677 940.500 0.259 0.053 5.708 1.186 0.642 0.093 21000.0 0.268 26.028 3.742 940.161 0.267 0.056 5.757 1.223 0.663 0.099 21500.0 0.266 25.664 3.806 839.822 0.275 0.059 5.804 1.259 0.685 0.105 22000.0 0.264 25.306 3.969 939.482 0.283 0.062 5.849 1.298 0.706 0.111 22600.0 0.262 24.951 3.932 939.141 0.291 0.065 5.893 1.331 0.727 0.117 23000.0 0.261 24.599 3.993 938.800 0.300 0.069 5.934 1.367 0.749 0.124 23500.0 0.259 24.250 4.054 938.457 0.308 0.072 5.974 1.402 0.770 0.131 24000.0 0.257 23.905 4.113 938.114 0.316 0.076 6.011 1.438 0.791 0.138 24500.0 0.255 23.563 4.172 937.770 0.324 0.080 6.048 1.474 0.812 0.145 25000.0 0.253 23.224 4.230 937.424 0.333 0.083 6.083 1.509 0.833 0.152 25500.0 0.251 22.889 4.288 937.078 0.341 0.087 6.116 1.544 0.853 0.159 26000.0 0.250 22.557 4.344 936.730 0.348 0.091 6.148 1.579 0.874 0.167 26500.0 0.248 22.228 4.400 936.382 0.358 0.095 6.179 1.814 0.895 0.174 27000.0 0.246 21.902 4.454 936.032 0.366 0.100 6.208 1.648 0.915 0.182 27500.0 0.244 21.579 4.508 935.680 0.375 0.104 6.237 1.683 0.935 0.190 30000.0 0.236 20.014 4.766 933.905 0.417 0.127 6.361 1.551 1.035 0.233 32500.0 0.227 18.528 5.004 932.098 0.460 0.153 6.459 2.014 1.132 0.280 35000.0 0.219 17.118 5.223 930.258 0.502 0.181 6.534 2.171 1.223 0.330 37500.0 0.211 15.784 5.422 928.387 0.545 0.211 6.589 2.322 1.309 0.385 40000.0 0.203 14.523 5.603 926.482 0.587 0.244 6.626 2.466 1.389 0.442 42500.0 0.195 13.334 5.766 924.545 0.628 0.279 6.647 2.604 1.464 0.503 45000.0 0.188 12.215 5.912 922.574 0.668 0.316 6.656 2.734 1.533 0.567 47500.0 0.181 11.166 6.040 920.570 0.707 0.354 6.662 2.858 1.596 0.633 50000.0 0.174 10.183 6.152 918.534 0.745 0.394 6.639 2.974 1.654 0.702 52500.0 0.167 9.265 6.248 916.464 0.781 0.435 6.618 3.082 1.706 0.773 55000.0 0.161 8.411 6.329 914.362 0.816 0.477 6.591 3.184 1.753 0.847 57500.0 0.154 7.618 6.395 912.229 0.849 0.519 6.558 3.278 1.795 0.922 60000.0 0.149 6.883 6.447 910.064 0.880 0.562 6.521 3.365 1.833 0.999 62500.0 0.143 6.206 6.485 907.869 0.909 0.605 6.482 3.444 1.865 1.078 65000.0 0.138 5.582 6.512 905.644 0.936 0.647 6.440 3.517 1.894 1.158 67500.0 0.133 5.010 6.526 903.392 0.961 0.689 6.397 3.583 1.518 1.240 70000.0 0.128 4.487 6.529 501.112 0.984 0.730 6.354 3.643 1.940 1.322 AREVA Inc.
Con ro~ ccd Doc~ument Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page C-35 Table C.34 [ ] Exposure-Dependent 0% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 0-235 0-238 U-238 NP-237 PU-238 5U-239 pU-240 PU-241 90-242 0.0 0.355 44.360 0.000 955.285 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.355 44.240 0.022 955.236 0.000 0.000 0.018 0.000 0.000 0.000 500.0 0.353 43.762 0.111 955.038 0.001 0.000 0.178 0.001 0.000 0.000 1000.0 0.351 43.171 0.220 954.791 0.003 0.000 0.384 0.006 0.000 0.000 1500.0 0.349 42.588 0.328 954.543 0.005 0.000 0.580 0.014 0.001 0.000 2000.0 0.347 42.013 0.433 954.295 0.007 0.000 0.768 0.024 0.002 0.000 2500.0 0.345 41.444 0.538 954.047 0.010 0.000 0.947 0.037 0.004 0.000 3000.0 0.344 40.883 0.641 953.799 0.012 0.000 1.119 0.051 0.006 0.000 3500.0 0.342 40.327 0.742 953.551 0.015 0.000 1.282 0.068 0.010 0.000 4000.0 0.340 39.778 0.842 953.302 0.018 0.001 1.438 0.088 0.014 0.000 4500.0 0.338 39.235 0.941 953.054 0.021 0.001 1.587 0.106 0.019 0.001 5000.0 0.336 38.698 1.038 952.805 0.024 0.001 1.730 0.127 0.025 0.001 5500.0 0.334 38.187 1.134 952.557 0.027 0.001 1.686 0.149 0.031 0.001 6000.0 0.332 37.640 1.229 952.308 0.031 0.001 1.995 0.172 0.039 0.002 6500.0 0.331 37.119 1.323 952.059 0.034 0.002 2.119 0.198 0.047 0.002 7000.0 0.329 35.604 1.415 951.811 0.038 0.002 2.237 0.221 0.058 0.003 7500.0 0.327 36.093 1.506 951.562 0.042 0.002 2.349 0.247 0.066 0.003 9000.0 0.325 35.587 1.596 951.313 0.048 0.003 2.456 0.274 0.077 0.004 8500.0 0.324 35.086 1.685 951.065 0.050 0.003 2.558 0.301 0.088 0.005 9000.0 0.322 34.590 1.773 950.816 0.054 0.004 2.655 0.328 0.100 0.006 9500.0 0.320 34.098 1.860 550.568 0.058 0.004 ,2.747 0.355 0.112 0.007 10000.0 0.318 33.610 1.946 950.319 0.063 0.005 2.835 0.385 0.125 0.009 10500.0 0.317 33.127 2.030 950.071 0.067 0.005 2.917 0.414 0.138 0.010 11000.0 0.315 32.648 2.114 949.523 0.072 0.006 2.996 0.443 0.152 0.012 11500.0 0.313 32.172 2.196 949.575 0.076 0.007 3.071 0.473 0.166 0.014 12000.0 0.312 31.701 2.278 949.326 0.081 0.007 3.141 0.503 0.181 0.016 12500.0 0.310 31.234 2.359 949.079 0.086 0.008 3.207 0.534 0.196 0.018 13000.0 0.308 30.771 2.438 948.831 0.091 0.009 3.270 0.564 0.211 0.020 13500.0 0.307 30.311 2.517 948.584 0.096 0.010 3.329 0.595 0.225 0.023 14000.0 0.305 29.855 2.595 948.337 0.101 0.011 3.384 0.626 0.241 0.026 14500.0 0.303 29.402 2.672 948.050 0.106 0.012 3.436 0.657 0.257 0.028 15000.0 0.302 28.953 2.748 947.843 0.111 0.013 3.484 0.699 0.272 0.032 15500.0 0.300 28.507 2.823 947.597 0.116 0.014 3.530 0.720 0.288 0.035 16000.0 0.298 28.064 2.897 947.351 0.122 0.015 3.572 0.752 0.304 0.039 16500.0 0.297 27.625 2.971 947.106 0.127 0.015 3.611 0.783 0.319 0.042 17000.0 0.295 27.189 3.043 946.860 0.132 0.017 3.647 0.615 0.335 0.046 17500.0 0.293 26.755 3.115 946.615 0.137 0.018 3.681 0.845 0.350 0.049 18000.0 0.292 26.325 3.186 946.369 0.143 0.019 3.712 0.878 0.366 0.054 18500.0 0.290 25.898 3.257 946.123 0.148 0.021 3.741 0.910 0.382 0.058 19000.0 0.289 25.475 3.326 945.877 0.154 0.022 3.768 0.941 0.397 0.063 19500.0 0.287 25.054 3.395 945.629 0.156 0.023 3.794 0.972 0.413 0.067 20000.0 0.285 24.636 3.463 945.381 0.185 0.025 3.817 1.004 0.426 0.072 20500.0 0.284 24.222 3.530 945.131 0.170 0.028 3.839 1.035 0.444 0.077 21000.0 0.282 23.812 3.597 944.880 0.176 0.028 3.860 1.066 0.460 0.083 22500.0 0.277 22.599 3.791 944.119 0.193 0.033 3.913 1.158 0.506 0.100 25000.0 0.269 20.645 4.101 942.821 0.224 0.042 3.978 1.309 0.584 0.134 27500.0 0.281 18.775 4.391 941.483 0.255 0.053 4.015 1.454 0.858 0.173 30000.0 0.253 18.990 4.682 940.104 0.287 0.006 4.028 1.594 0.727 0.217 32500.0 0.245 15.292 4.913 938.680 0.321 0.081 4.022 1.729 0.791 0.268 35000.0 0.237 13.882 5.145 937.208 0.354 0.097 3.999 1.856 0.849 0.325 37500.0 0.229 12.153 5.357 935.585 0.388 0.114 3.952 1.976 0.901 0.388 40000.0 0.221 10.736 5.548 934.106 0.422 0.134 3.914 2.088 0.946 0.456 42500.0 0.213 9.403 5.720 932.469 0.458 0.154 3.858 2.191 0.994 0.530 45000.0 0.204 8.168 5.870 930.768 0.489 0.176 3.796 2.285 1.015 0.610 47500.0 0.198 7.033 6.000 929.001 0.521 0.199 3.730 2.370 1.040 0.695 50000.0 0.188 5.998 6.108 927.164 0.553 0.223 3.683 2.445 1.059 0.785 52500.0 0.180 5.066 8.195 925.255 0.583 0.247 3.596 2.511 1.073 0.879 55000.0 0.172 4.235 6.262 923.272 0.611 0.270 3.531 2.567 1.082 0.977 57500.0 0.164 3.504 6.308 921.215 0.637 0.294 3.470 2.613 1.087 1.079 60000.0 0.156 2.889 6.338 919.084 0.882 0.317 3.412 2.651 1.088 1.183 82500.0 0.148 2.327 6.345 916.884 0.684 0.338 3.380 2.681 1.087 1.289 85000.0 0.140 1.869 6.337 914.818 0.704 0.358 3.313 2.704 1.084 1.398 67500.0 0.133 1.489 6.314 912.291 0.721 0.377 3.272 2.720 1.080 1.504 70000.0 0.126 1.178 6.279 909.910 0.736 0.393 3.236 2.731 1.076 1.611 AREVA Inc.
Controiled Dhocunent Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page C-36 Table C.35 [ ] Exposure-Dependent 40%
Void Isotopics (kgIMTU Initial)
Exposure MAWd/14TU1 0-234 0-235 0-236 U-238 NP-237 PU-238 PU-239 PU-240 P0-241 P0-242 0.0 0.355 44.380 0.000 955.285 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.354 44.240 0.023 955.229 0.000 0.000 0.020 0.000 0.000 0.000 500.0 0.353 43.764 0.115 955.003 0.002 0.000 0.202 0.001 0.000 0.000 1000.0 0.351 43.178 0.228 954.721 0.004 0.000 0.435 0.007 0.000 0.000 1500.0 0.348 42.597 0.339 954.439 0.006 0.000 0.658 0.015 0.001 0.000 2000.0 0.346 42.026 0.449 954.156 0.009 0.000 0.870 0.027 0.003 0.000 2500.0 0.344 41.453 0.556 953.874 0.011 0.000 1.073 0.041 0.005 0.000 3000.0 0.342 40.908 0.652 953.592 0.014 0.000 1.266 0.057 0.008 0.000 3500.0 0.340 40.350 0.766 953.310 0.018 0.001 1.451 0.076 0.012 0.000 4000.0 0.338 38.819 0.869 953.029 0.021 0.001 1.628 0.098 0.018 0.000 4500.0 0.336 39.284 0.970 952.746 0.025 0.001 1.797 0.117 0.024 0.001 5000.0 0.334 38.756 1.069 952.464 0.029 0.001 1.958 0.140 0.032 0.001 5500.0 0.332 38.234 1.167 952.182 0.032 0.002 2.112 0.164 0.040 0.001 6000.0 0.330 37.718 1.264 951.901 0.036 0.002 2.299 0.189 0.049 0.002 6500.0 0.328 37.208 1.359 951.619 0.041 0.002 2.399 0.215 0.060 0.003 7000.0 0.326 36.703 1.453 951.337 0.045 0.003 2.533 0.241 0.071 0.003 7500.0 0.324 36.204 1.545 951.056 0.050 0.003 2.661 0.269 0.083 0.004 8000.0 0.322 35.710 1.637 950.775 0.054 0.004 2.783 0.297 0.096 0.005 8500.0 0.320 35.222 1.726 950.494 0.0589 0.004 2.899 0.326 0.109 0.006 9000.0 0.318 34.738 1.815 950.213 0.064 0.005 3.009 0.355 0.123 0.008 9500.0 0.318 34.259 1.903 949.933 0.069 0.006 3.115 0.385 0.138 0.009 10000.0 0.314 33.785 1.889 949.652 0.074 0.006 3.215 0.415 0.153 0.011 10500.0 0.313 33.316 2.074 949.372 0.080 0.007 3.311 0.446 0.169 0.012 11000.0 0.311 32.851 2.158 949.092 0.085 0.008 3.401 0.477 0.186 0.014 11500.0 0.309 32.390 2.240 948.812 0.091 0.009 3.487 0.509 0.202 0.016 12000.0 0.307 31.934 2.322 948.533 0.096 0.010 3.569 0.540 0.219 0.019 12500.0 0.305 31.482 2.403 948.254 0.102 0.011 3.646 0.572 0.237 0.021 13000.0 0.303 31.034 2.482 947.976 0.108 0.012 3.719 0.605 0.254 0.024 13500.0 0.301 30.590 2.561 947.697 0.114 0.013 3.789 0.837 0.272 0.027 14000.0 0.300 30.149 2.638 947.419 0.120 0.014 3.854 0.670 0.250 0.030 14500.0 0.298 29.713 2.715 947.142 0.126 0.015 3.915 0.703 0.308 0.033 15000.0 0.298 29.280 2.790 946.865 0.132 0.016 3.973 0.736 0.328 0.036 15500.0 0.294 28.851 2.865 946.588 0.138 0.018 4.027 0.769 0.344 0.040 16000.0 0.292 28.425 2.939 946.312 0.144 0.019 4.078 0.802 0.382 0.044 16500.0 0.291 28.003 3.012 946.036 0.150 0.021 4.125 0.835 0.381 0.048 17000.0 0.289 27.584 3.084 945.761 0.156 0.022 4.169 0.869 0.399 0.052 17500.0 0.287 27.168 3.155 945.486 0.182 0.024 4.211 0.902 0.417 0.056 18000.0 0.288 26.756 3.225 945.211 0.166 0.025 4.250 0.935 0.435 0.061 18500.0 0.284 26.346 3.294 944.936 0.174 0.027 4.288 0.969 0.453 0.065 19000.0 0.282 25.940 3.363 "944.860 0.181 0.028 4.320 1.002 0.471 0.070 09500.0 0.280 25.537 3.431 944.384 0.187 0.030 4.352 1.035 0.489 0.076 20000.0 0.279 25.138 3.498 944.107 0.193 0.032 4.382 1.068 0.607 0.081 20500.0 0.277 24.741 3.564 943.829 0.200 0.034 4.410 1.101 0.524 0.086 21000.0 0.275 24.348 3.629 943.551 0.206 0.036 4.438 1.134 0.542 0.092 21500.0 0.274 23.958 3.693 943.271 0.213 0.038 4.461 1.186 0.580 0.098 22000.0 0.272 23.572 3.757 942.990 0.219 0.040 4.484 1.199 0.578 0.104 22500.0 0.270 23.189 3.820 942.707 0.226 0.042 4.506 1.231 0.585 0.111 25000.0 0.262 21.324 4.122 941.275 0.260 0.054 4.597 1.389 0.683 0.146 27500.0 0.254 19.543 4.405 939.806 0.296 0.068 4.658 1.542 0.768 0.186 30000.0 0.245 17.845 4.687 938.301 0.332 0.084 4.693 1.689 0.848 0.232 32500.0 0.237 16.231 4.910 936.756 0.369 0.101 4.706 1.830 0.922 0.283 35000.0 0.229 14.700 5.134 935.170 0.406 0.121 4.701 1.964 0.991 0.340 37500.0 0.221 13.253 5.339 933.541 0.443 0.142 4.680 2.090 1.052 0.401 40000.0 0.213 11.891 5.524 931.867 0.480 0.166 4.646 2.209 1.107 0.468 42500.0 0.205 10.813 5.690 930.145 0.516 0.190 4.601 2.319 1.155 0.539 45000.0 0.197 9.420 5.837 928.373 0.551 0.216 4.549 2.421 1.196 0.614 47500.0 0.190 8.312 5.965 926.550 0.586 0.244 4.490 2.514 1.231 0.694 50000.0 0.182 7.290 6.075 924.674 0.619 0.272 4.428 2.598 1.259 0.777 52500.0 0.175 6.352 6.165 922.743 0.651 0.300 4.361 2.673 1.282 0.864 55000.0 0.187 5.500 6.238 920.757 0.681 0.329 4.295 2.739 1.299 0.954 57500.0 0.160 4.729 6.292 918.715 0.710 0.358 4.229 2.796 1.311 1.046 60000.0 0.153 4.040 6.330 916.817 0.737 0.385 4.165 2.845 1.319 1.141 82500.0 0.146 3.428 6.351 914.465 0.761 0.413 4.104 2.886 1.323 1.237 65000.0 0.139 2.890 6.357 912.260 0.784 0.440 4.047 2.919 1.324 1.334 67500.0 0.133 2.421 6.349 910.005 0.804 0.465 3.894 2.946 1.323 1.432 70000.0 0.128 2.017 6.328 907.704 0.822 0.488 3.944 2.986 1.320 1.531 AREVA Inc.
Controlled Docunerit Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page C-37 Table C.36 [ ] Exposure-Dependent 80%
Void Isotopics (kg/MTU Initial)
Exposure M06d/M4TU 0-234 U-235 0-236 U-238 NP-237 PU-238 P0-239 PU-240 P0-241 P0-242 0.0 0.355 44.360 0.000 955.285 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.354 44.241 0.024 965.220 0.000 0.000 0.023 0.000 0.000 0.000 500.0 0.352 43.767 0.121 954.957 0.002 0.000 0.232 0.002 0.000 0.000 1000.0 0.350 43.184 0.239 954.629 0.005 0.000 0.501 0.009 0.000 0.000 1500.0 0.347 42.611 0.355 954.301 0.007 0.000 0.757 0.017 0.002 0.000 2000.0 0.345 42.047 0.469 953.973 0.011 0.000 1.002 0.030 0.004 0.000 2500.0 0.343 41.492 0.591 953.645 0.014 0.000 1.236 0.046 0.007 0.000 3000.0 0.340 40.946 0.691 953.318 0.018 0.001 1.459 0.054 0.011 0.000 3500.0 0.338 40.407 0.799 952.991 0.022 0.001 1.672 0.094 0.017 0.000 4000.0 0.335 39.676 0.906 952.664 0.026 0.001 1.877 0.105 0.024 0.001 4500.0 0.333 39.352 1.010 952.338 0.030 0.001 2.072 0.129 0.032 0.001 5000.0 0.331 38.839 1.113 952.012 0.035 0.002 2.259 0.152 0.041 0.001 5500.0 0.326 38.325 1.214 951.685 0.040 0.002 2.438 0.176 0.052 0.002 6000.0 0.326 37.921 1.313 951.360 0.045 0.003 2.610 0.204 0.063 0.002 6500.0 0.324 37.324 1.411 951.034 0.050 0.003 2.774 0.232 0.076 0.003 7000.0 0.322 36.933 1.507 950.709 0.056 0.004 2.931 0.260 0.090 0.004 7500.0 0.319 36.346 1.602 950.394 0.061 0.005 3.061 0.269 0.104 0.005 9000.0 0.317 35.969 1.695 950.059 0.067 0.005 3.225 0.319 0.120 0.006 6500.0 0.315 35.394 1.767 949.734 0.073 0.006 3.363 0.350 0.136 0.007 9000.0 0.313 34.926 1.977 949.410 0.079 0.007 3.495 0.381 0.153 0.009 9500.0 0.311 34.462 1.967 949.087 0.085 0.008 3.621 0.412 0.170 0.010 10000.0 0.305 34.004 2.054 946.763 0.092 0.009 3.741 0.445 0.188 0.012 10500.0 0.306 33.551 2.141 948.440 0.098 0.010 3.856 0.477 0.207 0.014 11000.0 0.304 33.103 2.226 949.117 0.108 0.011 3.966 0.510 0.226 0.016 11500.0 0.302 32.659 2.310 947.795 0.111 0.012 4.071 0.543 0.245 0.019 12000.0 0.300 32.220 2.393 947.473 0.118 0.014 4.171 0.577 0.268 0.021 12500.0 0.299 31.785 2.476 947.152 0.125 0.016 4.267 0.611 0.286 0.024 13000.0 0.296 31.355 2.655 946.831 0.132 0.017 4.357 0.646 0.306 0.027 13500.0 0.294 30.929 2.634 946.510 0.139 0.018 4.444 0.680 0.326 0.030 14000.0 0.292 30.507 2.712 946.190 0.146 0.020 4.526 0.715 0.347 0.033 14500.0 0.290 30.089 2.789 945.870 0.153 0.021 4.604 0.750 0.368 0.037 15000.0 0.288 29.676 2.865 945.551 0.160 0.023 4.678 0.786 0.369 0.040 15500.0 0.286 29.265 2.940 945.232 0.167 0.025 4.748 0.821 0.410 0.044 16000.0 0.294 28.859 3.014 944.914 0.175 0.027 4.915 0.857 0.431 0.048 16500.0 0.282 28.457 3.087 944.596 0.182 0.029 4.879 0.892 0.462 0.052 17000.0 0.280 28.058 3.158 944.279 0.189 0.031 4.937 0.928 0.473 0.057 17500.0 0.279 27.662 3.229 943.962 0.197 0.033 4.993 0.964 0.493 0.061 18000.0 0.277 27.270 3.299 943.645 0.204 0.035 5.046 1.000 0.514 0.066 18500.0 0.275 26.882 3.368 943.329 0.212 0.037 5.056 1.036 0.535 0.071 19000.0 0.273 26.497 3.436 943.013 0.219 0.040 5.143 1.072 0.555 0.076 19500.0 0.271 26.115 3.503 942.696 0.227 0.042 8.188 1.108 0.576 0.081 20000.0 0.269 25.736 3.565 942.379 0.234 0.045 6.231 1.144 0.596 0.087 20500.0 0.267 25.361 3.634 942.062 0.242 0.047 5.271 1.179 0.617 0.093 21000.0 0.266 24.989 3.699 941.744 0.249 0.050 5.309 1.215 0.637 0.099 21500.0 0.264 24.521 3.752 941.426 0.257 0.053 5.345 1.250 0.657 0.105 22000.0 0.262 24.255 3.825 941.106 0.264 0.056 5.380 1.286 0.678 0.111 22500.0 0.260 23.893 3.887 940.786 0.272 0.058 5.413 1.321 0.698 0.117 23000.0 0.258 23.535 3.948 940.464 0.280 0.061 5.444 1.356 0.718 0.124 23500.0 0.257 23.180 4.008 940.141 0.288 0.065 5.474 1.391 0.738 0.131 25000.0 0.251 22.134 4.184 939.165 0.311 0.074 5.555 1.495 0.798 0.152 27500.0 0.243 20.457 4.461 937.513 0.351 0.093 5.666 1.663 0.895 0.192 30000.0 0.234 18.861 4.717 935.827 0.391 0.113 5.748 1.825 0.989 0.236 32500.0 0.226 17.345 4.854 534.108 0.431 0.136 5.805 1.982 1.078 0.285 35000.0 0.218 15.908 5.172 932.354 0.472 0.161 5.841 2.133 1.162 0.338 37500.0 0.210 14.549 5.370 930.565 0.512 0.188 5.859 2.276 1.239 0.395 40000.0 0.202 13.267 5.549 928.739 0.552 0.218 5.560 2.413 1.310 0.456 42500.0 0.194 12.062 5.710 926.876 0.591 0.249 5.848 2.542 1.375 0.520 45000.0 0.187 10.930 5.852 924.976 0.629 0.282 5.825 2.663 1.434 0.588 47500.0 0.179 9.873 5.977 923.037 0.666 0.316 5.792 2.776 1.486 0.659 50000.0 0.172 8.887 6.085 921.060 0.702 0.351 5.751 2.880 1.533 0.733 52500.0 0.165 7.973 6.178 919.043 0.737 0.388 5.705 2.977 1.573 0.810 55000.0 0.159 7.127 6.251 916.989 0.770 0.424 5.654 3.065 1.608 0.889 57500.0 0.152 6.349 6.311 914.895 0.801 0.462 5.600 3.145 1.638 0.970 60000.0 0.146 5.635 6.356 912.764 0.630 0.499 5.545 3.217 1.662 1.054 62500.0 0.140 4.984 6.386 910.596 0.857 0.536 5.489 3.281 1.683 1.139 65000.0 0.134 4.393 6.403 908.391 0.882 0.572 6.433 3.338 1.699 1.325 67500.0 0.129 3.856 6.407 906.152 0.905 0.607 5.379 3.388 1.711 1.313 70000.0 0.123 3.379 6.400 903.880 0.926 0.641 5.326 3.431 1.721 1.402 AREVA Inc.
Controlled Docum ent Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page C-38 Table C.37 [ ] Exposure-Dependent 0% Void Isotopics (kgIMTU Initial)
Exposure l4Wd/MTO 50-239 5U-24 0 5U-241 PU-242 0-234 0-235 U-236 U-238 NP-237 PU-238 0.0 0.355 44.360 0.000 955.285 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.355 44.240 0.022 955.238 0.000 0.000 0.017 0.000 0.000 0.000 500.0 0.353 43.762 0.110 955.049 0.001 0.000 0.170 0.001 0.000 0.000 1000.0 0.351 43.171 0.218 954.812 0.003 0.000 0.367 0.006 0.000 0.000 1500.0 0.349 42.587 0.324 954.575 0.005 0.000 0.555 0.013 0.001 0.000 2000.0 0.348 42.011 0.429 954.337 0.007 0.000 0.735 0.023 0.002 0.000 2500.0 0.346 41.441 0.533 954.100 0.009 0.000 0.907 0.035 0.003 0.000 3000.0 0.344 40.878 0.635 953.862 0.012 0.000 1.070 0 .049 0.006 0.000 3500.0 0.342 40.320 0.735 953.624 0.014 0.000 1.227 0.065 0.009 0.000 4000.0 0.340 39.769 0.835 953.386 0.017 0.001 1.377 0.083 0.013 0.000 4500.0 0.339 39.224 0.933 953.148 0.020 0.001 1.519 0.102 0.017 0.000 5000.0 0.337 38.684 1.030 952.910 0.023 0.001 1. 656 0.122 0.023 0.001 5500.0 0.335 38.150 1.125 952.672 0.026 0.001 1.786 0.143 0.029 0.001 5000.0 0.333 37.821 1.220 952.433 0.029 0.001 1.910 0.166 0.036 0.001 5500 .0 0.332 37.097 1.313 952.195 0.033 0.002 2.029 0.1899 0.044 0.002 7000.0 0.330 36.578 1.405 951.956 0.036 0.002 2.141 0.214 0.052 0.002 7500.0 0.328 36.063 1.496 951.718 0.040 0.002 2.249 0 .239 0.061 0.003 8000.0 0.326 35.554 1.586 951.479 0.044 0.003 2.351 0.264 0.071 0.004 8500 .0 0.325 35.049 1.574 951.241 0.048 0.003 2.449 0.291 0.082 0.005 5000.0 0.323 34.548 1.782 951.002 0.052 0.004 2.541 0.318 0.093 0.006 5500.0 0.321 34.052 1.849 950.764 0.056 0.004 2. 629 0.345 0.104 0.007 10000.0 0.320 33.560 1.934 950.525 0.060 0.004 2.713 0.373 0.116 0.008 10500.0 0.318 33.073 2.019 950.287 0.064 0.005 2.792 0.402 0.129 0.010 11000.0 0.315 32.589 2.103 950.048 0.068 0.006 2.867 0.430 0.142 0.011 11500.0 0.315 32.109 2.185 949.810 0.073 0.006 2.938 0.459 0.155 0.013 12000.0 0.313 31.633 2.267 949.572 0.077 0.007 3.005 0.489 0.168 0.015 12500.0 0.311 31.161 2.348 949.334 0.082 0.008 3.068 0.519 0.182 0.017 13000.0 0.310 30.693 2.427 949.096 0.087 0.008 3.127 0.548 0.196 0.019 13500.0 0.308 30.228 2.506 949.859 0.092 0.009 3.183 0.579 0.211 0.021 14000.0 0.306 29.767 2.584 948.621 0.096 0.010 3.236 0.609 0.225 0.024 14500.0 0.305 29.309 2.681 848.384 0.101 0.011 3.285 0.640 0.240 0.027 15000.0 0.303 28.854 2.738 948.147 0.106 0.012 3.330 0 .670 0.255 0.030 15500.0 0.301 28.403 2.813 947.911 0.111 0.013 3.373 0.701 0.269 0.033 16000.0 0.300 27.954 2.888 947.675 0.116 0.014 3.412 0.732 0.284 0.036 16500.0 0.298 27.509 2.962 947.439 0.121 0.015 3.449 0.763 0.299 0.039 17000.0 0.297 27.067 3.035 947.203 0.126 0.016 3.483 0.794 0.314 0.043 17500.0 0.295 26.828 3.107 946.966 0.131 0.017 3.515 0.825 0.328 0.047 18000.0 0.293 26.192 3.179 946.730 0.136 0.018 3.544 0.856 0.343 0.051 18500.0 0.292 25.759 3.249 946.493 0.141 0.019 3.572 0.887 0.358 0.055 15000.0 0.290 26.330 3.319 946.255 0.147 0.020 3.597 0.918 0.373 0.059 15500.0 0.289 24.903 3.388 846.017 0.152 0.022 3.620 0 949 0.387 0.064 20000.0 0.297 24.480 3.457 945.777 0.157 0.023 3.642 0.980 0.402 0.069 20500.0 0.286 24.060 3.525 945.537 0.163 0.024 3.663 1.011 0.417 0.074 22500.0 0.279 22.412 3.788 944.559 0.185 0.030 3.731 1.132 0.477 0.095 25000.0 0.271 20.427 4.101 943.304 0.214 0.039 3.789 1.281 0.550 0.128 27500.0 0.283 18.526 4.394 942.008 0.244 0.050 3.819 1.425 0.620 0.166 30000.0 0.255 16.711 4.668 940.670 0.275 0.062 3.827 1.564 0.686 0.210 32500.0 0.247 14.983 4.923 939.285 0.307 0.075 3.816 1 .698 0.747 0.260 35000.0 0.239 13.345 5.158 937.849 0.340 0.090 3.788 1.824 0.802 0.316 37500.0 0.231 11.799 5.373 936.359 0.372 0.107 3.748 1. 943 0.950 0.378 40000.0 0.223 10.350 5.568 934.810 0.405 0.125 3.697 2.055 0.892 0.447 42500.0 0.214 8.998 5.741 933.198 0.438 0.145 3.638 2.157 0.927 0.521 45000.0 0.206 7.750 5.894 931.517 0.470 0.186 3.575 2.251 0.956 0.601 47500.0 0.198 6.606 6.024 929.764 0.502 0.187 3.509 2.334 0.978 0.687 50000.0 0.1899 5.570 6.132 927.934 0.532 0.210 3.442 2.408 0.995 0.779 52500.0 0.181 4.642 6.218 926.025 0.561 0.232 3.376 2.472 1.007 0.875 58000.0 0.172 3.824 6.283 924.035 0.588 0.254 3.313 2.527 1.014 0.976 57500.0 0.164 3.113 8.326 921.963 0.614 0.276 3.254 2.571 1.018 1.080 60000.0 0.156 2.504 6.349 919.812 0.637 0.297 3.200 2.607 1.018 1.188 82500.0 0.149 1.993 6.353 917.585 0.659 0.317 3.151 2.635 1 .017 1.297 65000.0 0.140 1.589 8.340 915.289 0.677 0.335 3.109 2.656 1.013 1.408 87500.0 0.132 1.225 6.313 912.929 0.693 0.352 3.072 2.670 1 .009 1.518 70000.0 0.125 0.949 6.272 910.516 0.707 0.367 3.041 2.679 1.004 1. 629 AREVA Inc.
Cont odled Documert Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM IOXM Fuel Page C-39 Table C.38 [ ] Exposure-Dependent 40% Void Isotopics (kg/MTU Initial)
Exposure M49d/MTU 0-234 0-235 0-236 0-238 N4P-237 P0-238 P0-239 PU-240 P0-241 P0-242 0.0 0.355 44.360 0.000 955.285 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.354 44.240 0.023 955.231 0.000 0.000 0.019 0.000 0.000 0.O000 500.0 0.353 43.764 0.114 955.013 0.002 0.000 0.194 0.001 0.000 0.000 1000.0 0.351 43.176 0.226 954.740 0.004 0.000 0.420 0.006 0.000 0.000 1500.0 0.349 42.596 0.336 954.468 0.006 0.000 0.635 0.015 0.001 0.000 2000.0 0.347 42.025 0.445 954.195 0.008 0.000 0.840 0.026 0.002 0.000 2500.0 0.345 41.461 0.551 953.922 0.011 0.000 1.035 0.040 0.005 0.000 3000.0 0.343 40.904 0.656 953.650 0.014 0.000 1.222 0.055 0.008 0.000 3600.0 0.341 40.354 0.760 953.377 0.017 0.001 1.401 0.073 0.012 0.000 4000.0 0.339 39.812 0.862 953.104 0.020 0.001 1.571 0.093 0.017 0.000 4500.0 0.337 38.275 0.962 552.832 0.024 0.001 1.734 0.113 0.023 0.001 5000.0 0.335 38.745 1.061 952.559 0.028 0.001 1.889 0.136 0.030 0.001 5500.0 0.333 38.220 1.159 952.287 0.031 0.002 2.038 0.159 0.037 0.001 6000.0 0.331 37.702 1.255 952.015 0.035 0.002 2.179 0.183 0.046 0.002 6500.0 0.329 37.189 1.350 951.742 0.039 0.002 2.315 0.209 0.056 0.002 7000.0 0.327 36.682 1.443 951.470 0.044 0.003 2.444 0.235 0.067 0.003 7500.0 0.325 36.180 1.935 951.198 0.048 0.003 2.567 0.262 0.079 0.004 8000.0 0.323 35.683 1.626 950.927 0.053 0.004 2.684 0.289 0.090 0.005 8500.0 0.321 35.291 1.716 950.655 0.057 0.004 2.796 0.319 0.103 0.006 9000.0 0.218 34.704 1.804 950.383 0.062 0.005 2.902 0.346 0.117 0.007 9900.0 0.317 34.222 1.891 950.112 0.067 0.005 3.003 0.376 0.131 0.008 10000.0 0.315 33.744 1.977 949.841 0.072 0.006 3.099 0.406 0.145 0.010 10500.0 0.314 33.271 2.062 949.570 0.077 0.007 3.181 0.436 0.160 0.012 11000.0 0.312 32.802 2.146 949.300 0.082 0.007 3.279 0.466 0.176 0.014 11500.0 0.310 32.338 2.228 949.029 0.088 0.008 3.360 0.497 0.192 0.016 12000.0 0.308 31.878 2.310 948.759 0.093 0.009 3.439 0.528 0.208 0.018 12500.0 0.306 31.421 2.391 948.490 0.099 0.010 3.512 0.560 0.225 0.020 13000.0 0.304 30.969 2.471 948.220 0.104 0.011 3.581 0.592 0.241 0.023 13500.0 0.303 30.521 2.549 947.951 0.110 0.012 3.647 0.624 0.258 0.025 14000.0 0.301 30.076 2.627 947.682 0.116 0.013 3.709 0.656 0.275 0.028 14500.0 0.299 29.635 2.704 947.414 0.221 0.014 3.767 0.688 0.293 0.031 15000.0 0.297 29.198 2.779 947.146 0.227 0.015 3.821 0.721 0.310 0.035 15500.0 0.296 28.754 2.894 846.879 0.133 0.017 3.873 0.753 0.327 0.038 16000.0 0.294 28.333 2.929 946.612 0.139 0.018 3.920 0.786 0.345 0.042 16500.0 0.292 27.906 3.001 946.345 0.144 0.019 3.965 0.819 0.362 0.046 17000.0 0.291 27.482 3.073 946.079 0.150 0.021 4.005 0.852 0.379 0.050 17500.0 0.289 27.061 3.145 945.813 0.156 0.022 4.045 0.994 0.397 0.054 18000.0 0.287 26.644 3.215 945.547 0.162 0.024 4.081 0.917 0.414 0.059 18500.0 0.295 26.229 3.285 945.281 0.168 0.025 4.115 0.950 0.431 0.063 19000.0 0.284 25.818 3.354 945.014 0.174 0.027 4.147 0.983 0.449 0.068 19500.0 0.282 25.410 3.422 944.747 0.180 0.028 4.175 1.015 0.465 0.073 20000.0 0.280 25.005 3.489 944.478 0.187 0.030 4.204 1.048 0.483 0.078 20500.0 0.279. 24.604 3.556 944.209 0.193 0.032 4.230 1.080 0.500 0.093 21000.0 0.277 24.206 3.621 943.939 0.199 0.034 4.254 1.112 0.517 0.089 21500.0 0.275 23.811 3.696 943.668 0.205 0.036 4.277 1.144 0.534 0.095 22500.0 0.272 23.031 3.914 943.121 0.218 0.040 4.319 1.208 0.558 0.107 25000.0 0.264 21.139 4.119 941.729 0.252 0.051 4.400 1.364 0.652 0.142 27500.0 0.256 19.332 4.403 940.302 0.296 0.064 4.452 1.514 0.733 0.181 30000.0 0.247 17.608 4.669 938.836 0.321 0.079 4.480 1.659 0.810 0.227 32500.0 0.239 15.968 4.914 937.329 0.357 0.096 4.486 1.798 0.891 0.278 35000.0 0.231 14.412 5.141 935.780 0.393 0.115 4.474 1.931 0.946 0.334 37500.0 0.223 12.942 5.348 934.186 0.429 0.135 4.447 2.056 1.004 0.395 40000.0 0.215 11.558 5.036 932.544 0.465 0.157 4.407 2.172 1.055 0.462 42500.0 0.207 10.262 5.704 930.852 0.500 0.182 4.357 2.291 1.100 0.533 45000.0 0.199 9.053 5.853 929.106 0.535 0.206 4.300 2.381 1.137 0.610 47500.0 0.191 7.933 5.982 927.306 0.569 0.232 4.237 2.472 1.169 0.690 50000.0 0.194 6.903 6.092 925.447 0.601 0.258 4.171 2.593 1.194 0.775 52500.0 0.176 5.962 6.192 923.530 0.632 0.285 4.103 2.625 1.213 0.863 55000.0 0.168 5.111 6.254 921.552 0.662 0.313 4.036 2.698 1.227 0.955 57500.0 0.161 4.347 6.307 919.513 0.690 0.340 3.969 2.743 1.236 1.050 60000.0 0.154 3.669 6.342 917.414 0.716 0.366 3.906 2.788 1.242 1.147 62500.0 0.146 3.073 6.361 915.255 0.739 0.392 3.946 2.825 1.243 1.246 65000.0 0.139 2.554 6.363 913.039 0.761 0.416 3.790 2.555 1.243 1.346 67500.0 0.133 2.108 6.351 910.759 0.780 0.439 3.739 2.979 1.240 1.447 70000.0 0.126 1.729 6.326 908.449 0.797 0.460 3.693 2.895 1.235 1.547 AREVA Inc.
ControIIed Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page C-40 Table C.39 [ ] Exposure-Dependent 80% Void Isotopics (kg/MTU Initial)
Exposure iWd/iSTO U-234 U-235 U-236 U-238 N19-237 PU-238 PU-239 PU-24 0 PU-241 50-242 0.0 0.355 44.360 0.000 955.285 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.354 44.241 0.024 955.221 0.000 0.000 0.023 0.000 0.000 0.000 500.0 0.352 43.768 0.120 954.963 0.002 0.000 0.228 0.002 0.000 0.000 1000.0 0.350 43.185 0.238 954.640 0.005 0.000 0.492 0.008 0.000 0.000 1500.0 0.348 42.612 0.353 954.317 0.007 0.000 0.743 0.017 0.001 0.000 2000.0 0.345 42.048 0.467 953.995 0.011 0.000 0.983 0.030 0.003 0.000 2500.0 0.343 41.493 0.578 953.673 0.014 0.000 1.213 0.045 0.006 0.000 3000.0 0.340 40.946 0.587 953.351 0.018 0.001 1.432 0.063 0.011 0.000 3500.0 0.338 40.407 0.795 953.030 0.022 0.001 1.641 0.082 0.016 0.000 4000.0 0.336 39.875 0.901 952.709 0.026 0.001 1 .841 0.104 0.023 0.001 4500.0 0.333 39.350 1.005 952.388 0.030 0.001 2.033 0.126 0.031 0.001 5000.0 0.331 38.833 1.107 952.067 0.035 0.002 2.216 0.150 0.040 0.001 5500.0 0.329 38.322 1.208 951.746 0.039 0.002 2.391 0.176 0.050 0.002 5000.0 0.327 37.817 1.307 951.426 0.044 0.003 2.559 0.202 0.061 0.002 6500.0 0.324 37.319 1.404 951.106 0.050 0.003 2.720 0.229 0.074 0.003 7000.0 0.322 36.827 1.600 950.786 0.055 0.004 2.8674 0.257 0.087 0.004 7500.0 0.320 36.340 1.594 950.467 0.061 0.004 3.021 0.286 0.101 0.005 5000.0 0.318 35.859 1.687 950.147 0.066 0.005 3.161 0.315 0.116 0.006 5500.0 0.316 35.384 1.779 949.829 0.072 0.006 3.296 0.346 0.132 0.007 9000.0 0.313 34.914 1.869 949.510 0.078 0.007 3.425 0.376 0.149 0.009 5500.0 0.311 34.449 1.958 949.192 0.084 0.008 3.547 0.408 0.166 0.010 10000.0 0.309 33.589 2.046 948.874 0.091 0.009 3. 665 0.440 0.183 0.012 10500.0 0.307 33.535 2.132 948.557 0.097 0.010 3.777 0.472 0.202 0.014 11000.0 0.305 33.084 2.217 949.240 0.103 0.011 3.884 0.504 0.220 0.016 11500.0 0.303 32.639 2.301 947.923 0.110 0.012 3.986 0.538 0.239 0.018 12000.0 0.301 32.198 2.384 947.607 0.117 0.013 4.083 0.571 0.259 0.021 12500.0 0.299 31.761 2.465 947.291 0.123 0.015 4.176 0. 605 0.278 0.023 13000.0 0.297 31.329 2.545 946.976 0.130 0.016 4.264 0. 639 0.298 0.026 13500.0 0.295 30.901 2.624 946.661 0.137 0.018 4.347 0. 673 0.319 0.029 14000.0 0.293 30.477 2.703 946.347 0.144 0.019 4 .427 0.708 0.339 0.033 14500.0 0.291 30.057 2.779 946.033 0.151 0.021 4 .502 0.742 0.359 0.036 15000.0 0.289 29.641 2.855 945.719 0.158 0.022 4 .574 0.777 0.380 0.040 15500.0 0.287 29.229 2.930 945.406 0.165 0.024 4. 641 0.812 0.400 0.043 16000.0 0.285 28.821 3.004 945.094 0.172 0.026 4.705 0.848 0.421 0.047 16500.0 0.283 28.416 3.077 944.782 0.179 0.028 4.766 0.883 0.441 0.051 17000.0 0.281 28.014 3.149 944.471 0.187 0.030 4.822 0. 918 0.4 62 0.056 17500.0 0.280 27.617 3.219 944.160 0.194 0.032 4.876 0.954 0.482 0.060 18000.0 0.278 27.222 3.289 943.849 0.201 0.034 4.927 0. 990 0.503 0.065 15500.0 0.276 26.831 3.358 943.538 0.209 0.036 4 .975 1.025 0.523 0.070 19000.0 0.274 26.443 3.426 943.228 0.216 0.039 5.020 1.061 0.54 3 0.075 19500.0 0.272 26.059 3.493 942.917 0.223 0.041 5.062 1.096 0.563 0.080 20000.0 0.270 25.678 3.560 942.606 0.231 0.043 5.103 1.131 0.583 0.086 20500.0 0.269 25.300 3.825 942.294 0.238 0.046 5.141 1.167 0. 603 0.091 21000.0 0.267 24.925 3.690 941.982 0.246 0.048 5.177 1.202 0.623 0.097 21500.0 0.265 24.554 3.753 941.669 0.253 0.051 5.211 1.237 0.643 0.103 22000.0 0.263 24.186 3.818 941.355 0.261 0.054 5.244 1.272 0.663 0.109 22500.0 0.261 23.821 3.878 941.040 0.268 0.057 5.275 1.307 0.682 0.116 23000.0 0.260 23.460 3.940 940.723 0.276 0.060 5.305 1.341 0.702 0.122 23500.0 0.258 23.102 4.000 940.406 0.283 0.063 5.333 1.376 0.722 0.129 25000.0 0.253 22.048 4.176 939.446 0.307 0.072 5.409 1.478 0.780 0.151 27500.0 0.244 20.357 4.454 937.820 0.346 0.090 5.511 1.644 0.876 0.190 30000.0 0.236 18.748 4.712 936.160 0.385 0.110 5.586 1.805 0.968 0.234 32500.0 0.227 17.219 4.950 934.466 0.425 0.132 5.636 1.959 1.054 0.283 35000.0 0.219 15.768 5.168 932.737 0.465 0.157 5. 665 2.108 1.136 0.336 37500.0 0.211 14.398 5.367 930.972 0.505 0.183 5. 676 2.249 1.211 0.393 40000.0 0.203 13.104 5.548 929.169 0.545 0.212 5. 671 2.383 1.279 0.455 42500.0 0.195 11.887 5.709 927.328 0.584 0.242 5. 653 2.509 1.342 0.520 45000.0 0.188 10.746 5.853 925.449 0.622 0.274 5. 623 2.628 1.398 0.58 8 47500.0 0.181 9.680 5.979 923.530 0.659 0.308 5.585 2.738 1.448 0.660 50000.0 0.173 8.667 6.087 921.570 0.694 0.342 5.540 2.840 1.491 0.736 52500.0 0.166 7.767 6.178 919.571 0.729 0.377 5.489 2.934 1.529 0.813 55000.0 0.160 6.917 6.254 917.531 0.761 0.413 5.434 3.019 1.561 0.893 57500.0 0.153 6.136 6.313 915.451 0.792 0.450 5.377 3.096 1.588 0.975 60000.0 0.147 5.422 6.357 913.330 0.821 0.486 5.319 3.164 1.610 1.060 52500.0 0.141 4.773 6.387 911.171 0.848 0.521 5.260 3.225 1.627 1.146 65000.0 0.135 4.185 6.403 908.974 0.872 0.556 9.202 3.279 1.641 1.234 67500.0 0.129 3.656 6.406 906.740 0.895 0.590 5.146 3.325 1.651 1.323 70000.0 0.124 3.182 0.397 904.471 0.915 0.622 5.091 3.364 1 .658 1.413 AREVA Inc.
Control ed Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 1OXM Fuel Page C-41 Table C.40 ( ] Exposure-Dependent 0% Void Isotopics (kgIMTU Initial)
Exposure XWd/MTU0 U-234 0-235 U-236 U-238 N4P-237 2U-238 PU-239 P0-24 0 PU-241 2U-242 0.0 0.355 44.359 0.000 955.286 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.355 44.239 0.022 955.240 0.000 0.000 0.017 0.000 0.000 0.000 500 .0 0.353 43.760 0.110 955.052 0.001 0.000 0.169 0.001 0.000 0.000 1000.0 0.351 43.169 0.218 954.816 0.003 0.000 0.365 0 .006 0.000 0.000 1500.0 0.349 42.585 0.324 954.581 0.005 0.000 0.552 0.013 0.001 0.000 2000.0 0.348 42.009 0.429 954.345 0.007 0.000 0.730 0.023 0.002 0.000 2500.0 0.346 41.439 0.532 954.110 0.009 0.000 0.900 0.035 0.003 0.000 3000.0 0.244 40.875 0.634 953.874 0.012 0.000 1.062 0.049 0.006 0.000 3500.0 0.342 40.317 0.735 953.639 0.014 0.000 1.217 0.065 0.009 0.000 4000.0 0.340 39.766 0.834 953.404 0.017 0.001 1.364 0.062 0.012 0.000 4500.0 0.335 39.220 0.932 953.169 0.020 0.001 1 .505 0.101 0.017 0.000 5000.0 0.337 38.679 1.029 952.934 0.023 0.001 1 .638 0 .122 0.022 0.001 5500.0 0.335 28.144 1.124 952.700 0.026 0.001 1 .766 0.143 0.028 0.001 6000.0 0.333 37.514 1.219 952.465 0.029 0.001 1.887 0.165 0.035 0.001 6500.0 0.332 37.089 1.312 952.231 0.032 0.002 2.003 0.189 0.043 0.002 7000.0 0.330 36.569 1.404 951.997 0.036 0.002 2.113 0.213 0.051 0.002 7500.0 0.328 36.054 1.494 951.763 0.039 0.002 2.217 0.238 0.060 0.003 8000.0 0.327 35.542 1.584 951.530 0.043 0.003 2.317 0.264 0.070 0.004 8500.0 0.325 35.036 1.673 951.297 0.047 0.003 2.411 0.280 0.080 0.005 9000.0 0.323 34.534 1.760 951.065 0.051 0.003 2.500 0.317 0 .090 0.006 9500.0 0.322 34.035 1.847 950.932 0.054 0.004 2.584 0.344 0.102 0.007 10000.0 0.320 33.541 1.933 950.601 0.058 0.004 2. 664 0 .372 0.113 0.008 10500.0 0.318 33.051 2.017 950.369 0.063 0.005 2.740 0.400 0.125 0.009 11000.0 0.317 32.564 2.101 950.138 0.067 0.005 2.811 0.426 0.138 0.011 11500.0 0.315 32.081 2.183 949.908 0.071 0.006 2.879 0.457 0.150 0.013 12000.0 0.313 31.602 2.265 949.678 0.075 0.007 2.942 0.486 0.163 0.014 12500.0 0.312 31.126 2.346 949.449 0.080 0.007 3.001 0.516 0.176 0.016 13000.0 0.310 30.654 2.426 949.220 0.084 0.008 3.057 0.545 0.190 0.018 13500.0 0.309 30.185 2.505 948.991 0.089 0.009 3.110 0.575 0.203 0.021 14000.0 0.307 29.719 2.583 948.763 0.093 0.009 3.159 0.605 0.217 0.023 14500.0 0.305 29.256 2.660 948.534 0.098 0.010 3.206 0.635 0.231 0.026 15000.0 0.304 28.797 2.737 948.305 0.103 0.011 3.250 0.665 0.245 0.028 15500.0 0.302 28.341 2.813 948.075 0.107 0.012 3.291 0 .695 0.259 0.031 15000.0 0.301 27.888 2.888 947.845 0.112 0.013 3.330 0.726 0.273 0.034 16500.0 0.299 27.439 2.962 947.614 0.117 0.014 3.367 0.756 0.288 0.038 17000.0 0.298 26.893 3.035 947.381 0.122 0.015 3.402 0.786 0.302 0.041 17500.0 0.296 26.550 3.108 947.148 0.127 0.016 3.435 0.817 0.317 0.045 20000.0 0.288 24.389 3.460 945.960 0.153 0.022 3.575 0. 968 0.392 0.066 22500.0 0.280 22.312 3.792 944.738 0.191 0.029 3.676 1.118 0.468 0.092 25000.0 0.272 20.321 4.105 943.478 0.210 0.038 3.744 1.265 0.542 0.124 27500.0 0.264 18.415 4.399 942.180 0.241 0.048 3.783 1. 409 0.612 0.162 30000.0 0.256 16.597 4.673 940.837 0.272 0.060 3.787 1.548 0.678 0.206 32500.0 0.248 14.868 4.928 939.447 0.304 0.074 3.791 1.682 0.739 0.256 35000.0 0.240 13.231 5.163 938.007 0.337 0.0899 3.768 1.810 0.794 0.312 37500.0 0.231 11.687 5.377 936.511 0.370 0.106 3.730 1.930 0.943 0.374 40000.0 0.223 10.240 5.571 934.956 0.403 0.124 3.682 2.043 0.885 0.442 42500.0 0.215 8.893 5.744 933.337 0.438 0.144 3.626 2.146 0.921 0.517 45000.0 0.206 7.649 5.895 931.649 0.469 0.165 3.564 2.241 0.950 0.597 47500.0 0.198 6.511 6.024 929.887 0.500 0.186 3.499 2.326 0.973 0. 683 50000.0 0.189 5.482 6.130 928.049 0.531 0.209 3.433 2.401 0.990 0.775 52500.0 0.181 4.563 6.215 926.131 0.560 0.231 3.369 2.466 1 .002 0.871 55000.0 0.172 3.753 6.278 924.132 0.597 0.254 3.305 2.522 1.010 0. 972 57500.0 0.184 3.050 6.319 922.051 0.613 0.276 3.247 2.567 1.014 1.077 60000.0 0.156 2.450 6.340 919.891 0.636 0.297 3.194 2.604 1.015 1.166 62500.0 0.148 1.947 6.343 917.655 0.657 0.317 3.147 2.632 1.014 1.294 65000.0 0.140 1.532 6.329 915.351 0.676 0.335 3.105 2.653 1.011 1.405 67500.0 0.132 1.194 6.300 912.984 0.692 0.352 3.069 2.668 1.007 1.516 70000.0 0.124 0.924 6.258 910.564 0.706 0.366 3.038 2.678 1.002 1.626 AREVA Inc.
Son roiled Doecumert Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page C-42 Table C.41 [ ] Exposure-Dependent 40% Void Isotopics (kgIMTU Initial)
Exposure MWd/MTUJ 0-334 0-235 0-236 0-236 NP-237 P0-238 2U-239 PU-240 P0-241 PU-242 0.0 0.355 44.359 0.000 955.266 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.364 44.239 0.023 955.233 0.000 0.000 0.019 0.000 0.000 0.000 500.0 0.353 43.762 0.114 965.016 0.002 0.000 0.193 0.001 0.000 0.000 1000.0 0.351 43.174 0.226 954.746 0.004 0.000 0.417 0.006 0.000 0.000 1500.0 0.349 42.594 0.336 954.475 0.006 0.000 0.630 0.015 0.001 0.000 2000.0 0.347 42.022 0.444 954.205 0.008 0.000 0.633 0.026 0.002 0.000 2500.0 0.345 41.458 0.551 953.935 0.011 0.000 1.026 0.040 0.005 0.000 3000.0 0.343 40.901 0.656 953.666 0.014 0.000 1.210 0.055 0.008 0.000 3500.0 0.341 40.351 0.759 953.397 0.017 0.001 1.386 0.073 0.012 0.000 4000.0 0.339 39.806 0.861 953.128 0.020 0.001 1.554 0.092 0.016 0.000 4500.0 0.337 39.271 0.961 952.659 0.024 0.001 1.713 0.113 0.022 0.001 5000.0 0.335 38.740 1.060 952.591 0.027 0.001 1.8656 0.135 0.029 0.001 5500.0 0.333 35.214 1.157 952.323 0.031 0.001 2.011 0.159 0.037 0.001 6000.0 0.331 37.655 1.253 952.056 0.035 0.002 2.149 0:183 0.046 0.002 6500.0 0.329 37.181 1.348 951.788 0.039 0.002 2.281 0.209 0.055 0.002 7000.0 0.327 36.572 1.441 951.522 0.043 0.003 2.406 0.234 0.066 0.003 7500.0 0.325 36.169 1.533 951.256 0.047 0.003 2.525 0.261 0.077 0.004 8000.0 0.323 35.671 1.624 950.990 0.051 0.003 2.639 0.299 0.088 0.005 8500.0 0.321 35.177 1.713 950.725 0.056 0.004 2.746 0.317 0.101 0.006 9000.0 0.320 34.698 1.802 950.460 0.061 0.005 2.849 0.345 0.114 0.007 9500.0 0.319 34.203 1.889 950.196 0.060 0.005 2.945 0.375 0.128 0.009 10000.0 0.316 33.723 1.975 949.933 0.070 0.006 3.038 0.404 0.142 0.010 10500.0 0.314 33.248 2.059 949.670 0.075 0.006 3.125 0.434 0.156 0.011 11000.0 0.312 32.776 2.143 949.408 0.080 0.007 3.207 0.455 0.171 0.013 11500.0 0.311 32.308 2.226 949.146 0.085 0.008 3.285 0.495 0.186 0.015 12000.0 0.309 31.845 2.307 948.885 0.091 0.009 3.359 0.526 0.202 0.017 12500.0 0.307 31.385 2.388 948.625 0.096 0.010 3.428 0.558 0.218 0.019 13000.0 0.305 30.928 2.468 948.365 0.101 0.011 3.494 0.599 0.233 0.022 13500.0 0.304 30.475 2.545 948.105 0.107 0.012 3.555 0.621 0.250 0.025 14000.0 0.302 30.026 2.624 947.847 0.112 0.013 3.613 0.552 0.256 0.027 14500.0 0.300 29.580 2.701 947.988 0.117 0.014 3.668 0.684 0.292 0.030 15000.0 0.298 29.138 2.777 947.330 0.123 0.015 3.720 0.716 0.299 0.033 15500.0 0.297 28.699 2.852 947.070 0.128 0.018 3.769 0.748 0.315 0.037 16000.0 0.295 28.264 2.926 946.811 0.134 0.017 3.816 0.780 0.332 0.040 16500.0 0.293 27.832 3.000 946.550 0.140 0.018 3.860 0.812 0.349 0.044 17000.0 0.292 27.404 3.072 946.289 0.146 0.020 3.902 0.844 0.386 0.048 17500.0 0.290 26.979 3.144 946.027 0.151 0.021 3.942 0.876 0.383 0.052 18000.0 0.288 26.557 3.215 945.764 0.157 0.023 3.980 0.908 0.400 0.056 18500.0 0.287 28.139 3.285 945.499 0.153 0.024 4.016 0.940 0.417 0.061 20000.0 0.281 24.906 3.481 944.598 0.182 0.029 4.113 1.035 0.469 0.079 22500.0 0.273 22.921 3.816 943.337 0.214 0.038 4.243 1.192 0.556 0.104 25000.0 0.265 21.022 4.122 941.940 0.247 0.049 4.336 1.346 0.641 0.138 27500.0 0.256 19.209 4.407 940.508 0.282 0.062 4.399 1.496 0.723 0.178 30000.0 0.248 17.481 4.873 939.037 0.318 0.077 4.435 1.541 0.799 0.2233 32500.0 0.240 15.839 4.919 937.526 0.354 0.094 4.448 1.780 0.871 0.373 30000.0 0.232 14.283 5.145 935.971 0.390 0.113 4.441 1.913 0.936 0.329 37500.0 0.224 12.914 5.352 934.371 0.427 0.133 4.419 2.039 0.994 0.391 40000.0 0.216 11.432 5.538 932.722 0.463 0.155 4.382 2.157 1.046 0.457 42500.0 0.208 10.139 5.706 931.023 0.498 0.179 4.335 2.267 1.091 0.529 45000.0 0.200 8.935 5.853 929.271 0.533 0.204 4.281 2.368 1.129 0.605 47500.0 0.192 7.820 5.981 927.462 0.567 0.230 4.220 2.460 1.160 0.656 50000.0 0.184 6.796 6.090 925.596 0.600 0.257 4.155 2.543 1.186 0.771 52500.0 0.176 5.863 6.179 923.670 0.631 0.284 4.089 2.616 1.206 0.859 55000.0 0.168 5.019 5.249 921.583 0.561 0.311 4.023 2.680 1.220 0.951 57500.0 0.161 4.263 6.300 919.635 0.688 0.339 3.958 2.735 1.230 1.046 60000.0 0.154 3.593 6.334 917.526 0.714 0.365 3.895 2.781 1.238 1.143 62500.0 0.145 3.005 6.350 915.359 0.738 0.391 3.836 2.819 1.238 1.243 65000.0 0.139 2.495 6.351 913.134 0.760 0.419 3.782 2.850 1.238 1.343 67500.0 0.132 2.057 6.338 910.955 0.779 0.438 3.732 2.873 1.235 1.444 70000.0 0.126 1.685 6.311 908.527 0.796 0.459 3.686 2.891 1.232 1.544 AREVA Inc.
Controlled Doeurnent Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page C-43 Table C.42 [ ] Exposure-Dependent 80% Void Isotopics (kg/MTU Initial)
Exposure f4WdffTU 0-224 0-235 0-226 17-238 NP-237 90-238 PU-239 P0-240 PU-241 P0-242 0.0 0.355 44.359 0.000 955.286 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.354 44.240 0.024 955.223 0.000 0.000 0.023 0.000 0.000 0.000 000.0 0.352 43.766 0.120 954.967 0.002 0.000 0.226 0.002 0.000 0.000 1000.0 0.350 43.183 0.237 954.647 0.000 0.000 0.487 0.008 0.000 0.000 1500.0 0.348 42.610 0.303 954.328 0.007 0.000 0.736 0.017 0.001 0.000 2000.0 0.346 42.046 0.466 964.009 0.010 0.000 0.973 0.030 0.003 0.000 2500.0 0.343 41.490 0.577 953.691 0.014 0.000 1.199 0.045 0.006 0.000 3000.0 0.340 40.943 0.686 963.373 0.027 0.001 1.414 0.063 0.011 0.000 3000.0 0.338 40.403 0.794 953.056 0.021 0.001 1.620 0.082 0.016 0.000 4000.0 0.336 38.871 0.899 952.740 0.026 0.001 1.817 0.104 0.023 0.001 4500.0 0.334 39.346 1.003 052.424 0.030 0.001 2.004 0.126 0.030 0.001 0000.0 0.331 38.827 1.105 952.108 0.034 0.002 2.183 0.100 0.039 0.001 0500.0 0.329 38.316 1.205 951.793 0.039 0.002 2.355 0.176 0.049 12002 6000.0 0.327 37.810 1.304 951.419 0.044 0.003 2.518 0.202 0.061 0.002 6900.0 0.320 37.311 1.401 951.165 0.049 0.003 2.674 0.229 0.073 0.003 7000.0 0.322 36.817 1.487 950.852 0.004 0.004 2.823 0.297 0.086 0.004 7000.0 0.320 36.330 1.591 950.538 0.059 0.004 2.966 0.286 0.100 0.005 8000.0 0.318 35.847 1.664 990.227 0.065 0.000 3.101 0.310 0.114 0.006 8000.0 0.316 35.370 1.775 949.916 0.071 0.006 3.231 0.345 0.130 0.007 9000.0 0.314 34.898 1.866 949.605 0.077 0.007 3.305 0.376 0.146 0.008 9500.0 0.312 34.431 1.904 949.290 0.083 0.008 3.472 0.407 0.162 0.010 10000.0 0.310 33.968 2.041 948.986 0.089 0.009 3.585 0.439 0.180 0.012 10500.0 0.308 33.512 2.127 948.677 0.095 0.010 3.681 0.471 0.197 0.014 11000.0 0.306 33.059 2.212 948.369 0.101 0.011 3.793 0.504 0.210 0.016 11000.0 0.304 32.611 2.296 948.062 0.107 0.012 3.880 0.037 0.233 0.018 12000.0 0.302 32.167 2.378 947.706 0.114 0.013 3.982 0.570 0.252 0.020 12500.0 0.300 31.727 2.460 947.450 0.120 0.014 4.069 0.604 0.271 0.023 13000.0 0.298 31.291 2.540 947.140 0.127 0.016 4.152 0.637 0.290 0.026 13000.0 0.206 30.859 2.619 946.841 0.133 0.017 4.231 0.671 0.309 0.029 14000.0 0.204 30.430 2.697 946.537 0.140 0.018 4.300 0.706 0.329 0.032 14500.0 0.202 30.006 2.774 946.234 0.147 0.020 4.376 0.740 0.348 0.030 10000.0 0.250 29.080 2.800 945.931 0.153 0.021 4.444 0.774 0.367 0.038 15500.0 0.268 29.169 2.925 945.628 0.160 0.023 4.508 0.809 0.387 0.042 16000.0 0.296 28.700 2.999 946.324 0.167 0.020 4.560 0.844 0.407 0.046 16500.0 0.284 28.345 3.072 945.021 0.174 0.027 4.628 0.878 0.427 0.0500 17000.0 0.253 27.939 3.144 944.717 0.181 0.029 4.683 0.913 0.446 0.054 17000.0 0.281 27.536 3.226 944.412 0.188 0.031 4.737 0.948 0.466 0.009 18000.0 0.279 27.137 3.286 944.106 0.190 0.033 4.788 0.982 0.486 0.063 18000.0 0.277 26.742 3.305 943.800 0.203 0.030 4.835 1.017 0.506 0.068 19000.0 0.275 26.350 3.424 943.492 0.210 0.037 4.883 1.052 0.026 0.073 19500.0 0.273 20.962 3.491 943.194 0.217 0.039 4.928 1.086 0.546 0.079 20000.0 0.272 20.077 3.558 942.874 0.225 0.042 4.971 1.121 0.966 0.083 22500.0 0.263 23.707 3.878 941.307 0.263 0.055 0.160 1.291 0.667 0.113 20000.0 0.254 21.924 4.177 938.708 0.301 0.070 5.300 1.409 0.767 0.147 27000.0 0.245 20.226 4.406 938.076 0.341 0.086 5.425 1.623 0.863 0.187 30000.0 ,0.236 18.612 4.714 936.411 0.381 0.107 5.510 1.783 0.995 0.231 32500.0 0.228 17.079 4.952 934.712 0.421 0.130 5.070 1.937 1.041 0.279 36000.0 0.220 15.628 0.170 932.977 0.462 0.154 0.607 2.086 1.122 0.332 37500.0 0.212 14.256 5.369 931.205 0.502 0.181 0.624 2.227 1.198 0.389 40000.0 0.204 12.963 5.049 929.396 0.541 0.209 5.620 2.362 1.266 0.451 42000.0 0.196 11.748 5.710 927.549 0.581 0.239 0.611 2.490 1.328 0.010 45000.0 0.189 10.610 5.852 920.662 0.619 0.272 0.586 2.609 1.380 0.594 47500.0 0.181 9.548 0.977 923.730 0.656 0.300 5.551 2.720 1.435 0.606 50000.0 0.174 9.560 6.084 921.769 0.692 0.340 5.508 2.823 1.479 0.731 02000.0 0.167 7.640 6.174 919.760 0.726 0.370 0.460 2.918 1.517 0.808 55000.0 0.260 6.802 6.247 917.712 0.709 0.421 5.408 3.004 1.040 0.899 07000.0 0.153 6.027 6.305 915.624 0.790 0.447 0.302 2.082 1.577 0.971 60000.0 0.147 0.320 6.348 913.495 0.819 0.483 5.296 3.102 1.599 1.056 62500.0 0.141 4.677 6.376 911.327 0.846 0.519 5.230 3.214 1.617 1.142 65000.0 0.135 4.097 6.390 909.121 0.871 0.504 5.182 3.268 1.631 1.230 67500.0 0.129 3.575 6.392 906.879 0.893 0.588 0.128 3.315 1.642 1.319 70000.0 0.124 3.108 6.381 904.601 0.913 0.620 0.070 3.355 1.640 1.409 AREVA Inc.
Controlled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 0-1 Appendix 0 Lattice Enrichment Distribution Maps AREVA Inc.
ContPo ld Docume~nt Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 0-2 c
I Figure D.1[ ] Enrichment Distribution AREVA Inc.
Controlled Document Nuclear Fuel Design Report AN P-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page D-3 Figure 0.2 ] Enrichment Distribution AREVA Inc.
Controlled Document Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page D-4
[
]
Figure 0.3[ ] Enrichment Distribution AREVA Inc.
Contr&olld Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page 0-5
[
Figure D.4 i[ ] Enrichment Distribution AREVA Inc.
Controlled Docum ,n*
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page D-6 C
I Figure 0.5 [ ] Enrichment Distribution AREVA Inc.
Controlled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page D-7
]
Figure D.6[ I Enrichment Distribution AREVA Inc.
Nuclear Fuei Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page D-8
]
Figure D.7 [ ] Enrichment Distribution AREVA Inc.
Con:roQed Documer*
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page D-9 E
I Figure 0.8[ J Enrichment Distribution AREVA Inc.
Cov*ro! ed Docvmen(
Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page D-1O Figure D.9 i J Enrichment Distribution AREVA Inc.
Controlled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 10XM Fuel Page D-11
[
]
Figure 0.10 [ ] Enrichment Distribution AREVA Inc.
Controil ed Docu ment Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Paqe D-12 v
[
Figure 0.11[ ]Enrichment Distribution AREVA Inc.
Controlled Documnent Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 1OXM Fuel Page D-13
]
Figure 0.12 [ ] Enrichment Distribution AREVA Inc.
n> ~ed o~urnent Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page D-14 I
]
Figure D.13 [ ]Enrichment Distribution AREVA Inc.
Cont ol ed Documnent Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page D-.15
[
I Figure D.14 [ ] Enrichment Distribution AREVA Inc.
Controlled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page D-16 Figure 0.15 [ J Enrichment Distribution AREVA Inc.
C*ontrailed Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 1OXM Fuel Page D-17
[
]
Figure 0.16[ ] Enrichment Distribution AREVA Inc.
Cntrolled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page 0-18 Figure D.17 [ ] Enrichment Distribution AREVA Inc.
Controlled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page D-19 C
Figure 0.18 [ ]Enrichment Distribution AREVA Inc.
Controlied Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page D-20
[
I Figure 0.19 [ ] Enrichment Distribution AREVA Inc.
Controlled Documnent Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page D-21 Figure 0.20 [ ] Enrichment Distribution AREVA Inc.
Cont rolled Document Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 10XM Fuel PaeD2
[
]
Figure 0.21 ]Enrichment Distribution AREVA Inc.
Controlled Document Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page D-23
]
Figure D.22 [ ] Enrichment Distribution AREVA Inc.
Co ntrolled Document Nuclear Fuel Design Report AN P-3294N P Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 1OXM Fuel Page D-24
]
Figure 0.23 ] Enrichment Distribution AREVA Inc.
Controlled Document Nuclear FuelUnit Design Report ANP-3294NP Quad Cities 2 Cycle 24 Revision I Representative Cycle ATRIUM 10XM Fuel Page D-25 C
I Figure D.24 [ ] Enrichment Distribution AREVA Inc.
Controlled Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision I Representative Cycle ATRIUM 1OXM Fuel Page D-26 Figure D.25 [ J Enrichment Distribution AREVA Inc.
Controlled Documennt Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM 10XM Fuel Page D-27 I
Figure 0.26[ ] Enrichment Distribution AREVA Inc.
Control ed Document Nuclear Fuel Design Report ANP-3294NP Quad Cities Unit 2 Cycle 24 Revision 1 Representative Cycle ATRIUM IOXM Fuel Page 0-28
[
]
Figure D.27 [ ] Enrichment Distribution AREVA Inc.