ML15244A308

From kanterella
Jump to navigation Jump to search
Clarifies Ref to Order Stating That Implementation of SPDS Complete.Review of SPDS Still Ongoing & Has Not Yet Been Resolved
ML15244A308
Person / Time
Site: Oconee  
Issue date: 09/24/1987
From: Pastis H
Office of Nuclear Reactor Regulation
To: Tucker H
DUKE POWER CO.
References
NUDOCS 8709290205
Download: ML15244A308 (3)


Text

Docket Nos.:

50-269, 50-270 and 50-287 Mr. H. B. Tucker, Vice President Nuclear Production Department SEP 24 17 Duke Power Company 422 South Church Street Charlotte, North Carolina 28242

Dear Mr. Tucker:

Subject:

Emergency Response Capability

Reference:

Oconee Nuclear Station, Units 1, 2 and 3 In a letter dated June 22, 1987, we stated that "the Orders confirm that the Technical Support Center and the Operational Support Center are complete in all respects except for Regulatory Guide 1.97 instrumentation; the Safety Parameters Display System (SPDS) is also complete". We would like to clarify the reference to the SPDS. The Order states that the implementation of the SPDS is complete. Our review, however, is still ongoing. Therefore, the SPDS issue has not yet been resolved. If you have any questions, please call me at (301) 492-7377.

Sincerely, Helen N. Pastis, Project Manager Project Directorate 11-3 Division of Reactor Projects, I/II cc:

See next page D15lil11ION:

NRC Local PDR PRC System PD#23 Reading MDuncan HPastis OGC-Bethesda 6-O924 ACRS (10) 97092996 D0269 JPartlow PDR EJordan F

SVarga GLai PD

/DRP-I/II PD 3/DRP-I/II PD#II-RP -I/II HPa s/mac u can KJabbour, Acting PD 09/11/87 09/ 1/87 09/<&/87

oj UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 z

SEP 87 Docket Nos.:

50-269, 50-270 and 50-287 Mr. H. B. Tucker, Vice President Nuclear Production Department Duke Power Company 422 South Church Street Charlotte, North Carolina 28242

Dear Mr. Tucker:

Subject:

Emergency Response Capability

Reference:

Oconee Nuclear Station, Units 1, 2 and 3 In a letter dated June 22, 1987, we stated that "the Orders confirm that the Technical Support Center and the Operational Support Center are complete in all respects except for Regulatory Guide 1.97 instrumentation; the Safety Parameters Display System (SPDS) is also complete". We would like to clarify the reference to the SPDS. The Order states that the implementation of the SPDS is complete. Our review, however, is still ongoing. Therefore, the SPDS issue has not yet been resolved. If you have any questions, please call me at (301) 492-7377.

Sincerely, Helen N. Pastis, Project Manager Project Directorate 11-3 Division of Reactor Projects, I/II cc:

See next page

Mr. H. B. Tucker Oconee Nuclear Station Duke Power Company Units Nos. 1, 2 and 3 cc:

Mr. A. V. Carr, Esq.

Mr. Paul Guill Duke Power Company Duke Power Company P. 0. Box 33189 Post Office Box 33189 422 South Church Street 422 South Church Street Charlotte, North Carolina 28242 Charlotte, North Carolina 28242 J. Michael McGarry, III, Esq.

Bishop, Liberman, Cook, Purcell & Reynolds 1200 Seventeenth Street, N.W.

Washington, D.C. 20036 Mr. Robert B. Borsum Babcock & Wilcox Nuclear Power Generation Division Suite 220, 7910 Woodmont Avenue Bethesda, Maryland 20814 Manager, LIS NUS Corporation 2536 Countryside Boulevard Clearwater, Florida 33515 Senior Resident Inspector U.S. Nuclear Regulatory Commission Route 2, Box 610 Seneca, South Carolina 29678 Regional Administrator, Region II U.S. Nuclear Regulatory Commission 101 Marietta Street, N.W., Suite 2900 Atlanta, Georgia 30323 Mr. Heyward G. Shealy, Chief Bureau of Radiological Health South Carolina Department of Health and Environmental Control 2600 Bull Street Columbia, South Carolina 29201 Office of Intergovernmental Relations 116 West Jones Street Raleigh, North Carolina 27603 Honorable James M. Phinney County Supervisor of Oconee County Walhalla, South Carolina 29621