e ile-ORB#4 Rdg HOrnstein NRC PDR DEisenhut EBlackwood L PDR JStolz OELD TERA-3 PWagner AEOD Dockets Nos 4-269, 50-270 IE-3 and 50-287 ACRS-10 Gray File MChatterton Wdohnston Mr. William 0. Parker, Jr.

Vice President - Steam Production Duke Power Company P. 0. Box 33189 422 South Church Street Charlotte, North Carolina 2824:

Dear Mr. Parker:

The NRC staff has recently completed the review of the "Oconee Nuclear Station Generic Start-up Testing Prgram" whch6 was submitted by letter dated June 4, 1980 and revised-letters dated June 11, July 11 a.d August 15, 1980.

The proposed programwhi6 describes the physics test program for the start-up of subsequent reload cores at the Oconee Nuclear Units was reviewed against the saff's endrsedfo level accepi nce criteria and remedial actions.e The staff finds the proposed start-up testing program to adequately address the NRC concerns.

We,. therefore, ncoclude that the program des cribed above is acceptable for all three Oconee Units for all future start-ups unless a reload involves significant changes which would require additional confirmatory testing.

Sincerely, Original signed by John F. Stolz, Chief Operating Reactors Branch #4 Division of Licensing cc:

See next page 8 104 02 0&

OFFICE B

C-B D4 L

SURNAMEO Pgner/c, DATEj 3/to/81 f4_i NRC FORM 318410/80)NRCM0240 OFFICIAL RECORD COPY.

USGPO: 1980-329-e

05 UNITED STATES A..

1~0 NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 March 23, 1981 Dockets Nos. 50-269, 50-270 and 50-287 Mr. William 0. Parker, Jr.

Vice President -

Steam Production Duke Power Company P. 0. Box 33189 422 South.Church Street Charlotte, North Carolina 28242

Dear Mr. Parker:

The NRC staff has recently completed the review of the "Oconee Nuclear Station Generic Start-up Testing Program" which was submitted by letter dated June 4, 1980 and revised by letters dated June 11, July 11 and August 15, 1980. The proposed program, which describes the physics test program for the start-up of subsequent reload cores at the Oconee Nuclear Units, was reviewed against the staff's endorsed policy for tests, two level acceptance criteria and remedial actions.

The staff finds the proposed start-up. testing program to adequately address the NRC concerns. We, therefore, conclude that the program des cribed above is acceptable for all three Oconee Units for all future start-ups unless a reload involves significant changes which would require additional confirmatory testing.

Sincerely, J n F. Stolz, Chief perating Reactors Branch #4 Division of Licensing cc:

See next page

Duke Power Company cc w/enclosure(s):

Mr. William L. Porter Duke Power Company P. 0. Box 33189 422 South Church Street Office of Intergovernmental Relations Charlotte, North Carolina 28242 116 West Jones Street Raleigh, North Carolina 27603 Oconee County Library 501 West Southbroad Street Walhalla, South Carolina 29691 Honorable James M. Phinney County Supervisor of Oconee County Walhalla, South Carolina 29621 Director, Criteria and Standards Division.

Office of Radiation Programs (ANR-460)

U. S. Environmental Protection Agency Washington, D. C. 20460 U. S. Environmental Protection Agency Region IV Office ATTN:

EIS COORDINATOR 345 Courtland Street, N.E.

Atlanta, Georgia 30308 Mr. Francis Jape U.S. Nuclear Regulatory Commission Route 2, Box 610 Seneca, South Carolina 29678 Mr. Robert B. Borsum Babcock & Wilcox Nuclear Power Generation Division Suite 420, 7735 Old Georgetown Road Bethesda, Maryland 20014 Manager, LIS NUS Corporation 2536 Countryside Boulevard Clearwater, Florida 33515 J. Michael McGarry, III, Esq.

DeBevoise & Liberman 1200 17th Street, N.W.

Washington, D. C. 20036