Forwards SER Based on Review of Mechanical Response to Primary Coolant Sys Subjected to Asymmetric LOCA Loads. Util Assessment of Asymmetric Loads Problem Acceptable
ML15238A802
Person / Time
Site: Oconee  
Issue date: 05/20/1983
From: Stolz J
Office of Nuclear Reactor Regulation
To: Tucker H
DUKE POWER CO.
Shared Package
ML15238A803 List:
References
NUDOCS 8305310083
Download: ML15238A802 (2)


Text

Gistributin M~

,NChokshi GLear VBrownlee, R:II ORB#4 DEisenhut ORAB RIngram Docket Nos. 50-269 Rlngra 550-270 OELD and 50-287 Edordan TBarnhart 4 ACRS 10 OPS, CMiles NS IC Mr. H. B. Tucker JTaylor Vice President -

Nuclear -

SECY Production Department RDigg s Duke Power Company Gray P. 0. Box 33189 422 South Church Street Charlotte, North Carolina 28242

Dear Mr. Tucker:

The staff and its consultants have completed the review of the mechanical response of the primary coolant system subjected to asymmetric loss-of coolant accident loads for Oconee Nuclear Station, Unit Nos. 1, 2 and 3 which was submitted by report dated July, 1980 and revised by report dated June, 1981.

The results of our review are contained in the en closed Safety Evaluation.

The review included ain evaluation of plant cavity pressure, sabeooled blowdown and structural analyses. The staff has concluded that your assessment of the asymmetric loads problem is acceptable, and a re sonable assurancd has, been demonstrated that the reactor can be brought safely to a cold shutdown condition.

If you have any cpestions on this subject, please contact your NRC Project Manager.

Sincerely, John F. Stolz, Chief Operating Reactors Branch #4 Division of Licensing

Enclosure:

Safety Evaluation cc w/enclosure:

See next page 830531008 PDR ADoCXo o3oo20 PDR OFFICE RB#4.

DL:ORB#4

.DL:ORB#4 T.

SURNAME.

R JSuermann..

JStolz NRC..

FORM.....

318....

(10-0).RCM0240O.F.ICIA.LRE.O.R.C NRC FORM 318 (10-80) NRCM 0240 OFFICIAL RECORD COPY USGPO: 1981-335-960

0j0 Duke Power Company cc w/enclosure(s):

Mr. William L. Porter Duke Power Company P. 0. Box 33189 422 South Church Street Office of Intergovernmental Relations Charlotte, North Carolina 28242 116 West Jones Street Raleigh, North Carolina 27603 Honorable James M. Phinney County Supervisor of Oconee County Walhalla, South Carolina 29621 Mr. James P. O'Reilly, Regional Administrator U. S. Nuclear Regulatory Commission, Region II 101 Marietta Street, Suite 3100 Atlanta, Georgia 30303 Reqional Radiation Representative EPA Region IV 345 Courtland Street, N.E.

Atlanta, Georgia 30308 Mr. J. C. Bryant Senior Resident Inspector U.S. Nuclear Regulatory Commission Route 2, Box 610 Seneca, South Carolina 29678 Mr. Robert B. Borsum Babcock & Wilcox Nuclear Power Generation Division Suite 220, 7910 Woodmont Avenue Bethesda, Maryland 20814 Manager, LIS NUS Corporation 2536 Countryside Boulevard Clearwater, Florida 33515 J. Michael McGarry,*III, Esq.

DeBevoise & Liberman 1200 17th Street, N.W.