Informs Licensee That Subject Methodologies Audit Scheduled for 950306-10 & Provides List of Info to Be Reviewed
ML15238A031
Person / Time
Site: Oconee, Mcguire, Catawba, McGuire  
Issue date: 02/13/1995
From: Wiens L
Office of Nuclear Reactor Regulation
To: Tuckman M
DUKE POWER CO.
References
TAC-M89554, TAC-M89555, TAC-M89556, NUDOCS 9502170128
Download: ML15238A031 (5)


Text

February 13, 1995 Mr. M. S. Tuckman Senior Vice President Nuclear Generation Duke Power Company P. 0. Box 1006 Charlotte, North Carolina 28201-1006

SUBJECT:

NRC AUDIT OF DUKE POWER COMPANY'S USE OF TACO-3 AND THE FUEL ROD GAS PRESSURE CRITERION (FRGPC) FOR THE OCONEE, MCGUIRE, AND CATAWBA NUCLEAR STATIONS (TAC NOS. M89554, M89555, AND M89556)

Dear Mr. Tuckman:

Your letter dated August 24, 1994, informed us that the documentation supporting Duke Power Company's (DPC) application of the subject methodologies would be available for audit by September 19, 1994. This audit is scheduled to be conducted March 6 through 10, 1995, in the DPC general offices. The audit team will consist of Shih-Liang Wu of the Reactor Systems Branch of NRR and Carl Beyer of Pacific Northwest Laboratories. A list of the information to be reviewed is.enclosed with this letter. The need to review additional information may be identified during the audit. This information has been previously provided to Scott Gewehr of your staff.

If you have questions regarding this matter, contact me at (301) 415-1495.

Sincerely,

/s/

Leonard A. Wiens, Senior Project Manager Project Directorate 11-3 Division of Reactor Projects -

I/II Office of Nuclear Reactor Regulation Docket Nos. 50-269, 50-270, 50-287 50-369, 50-370, and 50-413, 50-414

Enclosure:

As stated cc w/enclosure: See next page DISTRIBUTION:

D k FITIe RMartin PUBLIC VNerses PDII-3 R/F

OGC, 15Bl8 SVarga ACRS (4)

JZwolinski EMerschoff, RH RCrlenjak, RII LWiens DOCUMENT NAME: G:\\OCONEE\\TACOAUDI To receive a copy of this document, indicate in the box: "C" = Copy without attachment/enclosure;1 "E" = Copy with attachment/enclosure "N"

= No copy OFFICE LA:PD23:DRPE

\\

E PM:PD23: RPE If D:PD I

NAME LBERRY LWIENS

~

HBER W

DATE

/95

/1-/

/

/95 1

/95 9502170128 950213 ICIAL RECORQ QX PDR ADOCK 05000269 P

PDR V 9 q~ort CO

REG(Z UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 February 13, 1995 Mr. M. S. Tuckman Senior Vice President Nuclear Generation Duke Power Company P. 0. Box 1006 Charlotte, North Carolina 28201-1006

SUBJECT:

NRC AUDIT OF DUKE POWER COMPANY'S USE OF TACO-3 AND THE FUEL ROD GAS PRESSURE CRITERION (FRGPC) FOR THE OCONEE, MCGUIRE, AND CATAWBA NUCLEAR STATIONS (TAC NOS. M89554, M89555, AND M89556)

Dear Mr. Tuckman:

Your letter dated August 24, 1994, informed us that the documentation supporting Duke Power Company's (DPC) application of the subject methodologies would be available for audit by September 19, 1994. This audit is scheduled to be conducted March 6 through 10, 1995, in the DPC general offices. The audit team will consist of Shih-Liang Wu of the Reactor Systems Branch of NRR and Carl Beyer of Pacific Northwest Laboratories. A list of the information to be reviewed is enclosed with this letter. The need to review additional information may be identified during the audit. This information has been previously provided to Scott Gewehr of your staff.

If you have questions regarding this matter, contact me at (301) 415-1495.

Sincerely, Leonard A. Wiens, Senior Project Manager Project Directorate 11-3 Division of Reactor Projects -

I/Il Office of Nuclear Reactor Regulation Docket Nos. 50-269, 50-270, 50-287 50-369, 50-370, and 50-413, 50-414

Enclosure:

As stated cc w/enclosure:

See next page

m0 Issues to be Discussed with Duke Power on Application of BWFC TACO-3 and Rod Pressure Analysis Methods The following are examples of the areas that will be discussed with Duke Power during the audits at Duke Power Company (DPC) but are not intended to be the only areas of inquiry.

I.

Code Applications

1. Define the analysis applications for which the TACO-3 code will be applied by DPC.
2. How are code, manufacturing, and power uncertainties determined?

How are they applied for each code application? Please provide examples.

3. How are power histories determined for each code application?

Please provide examples.

4. How are code input values determined for each application?

Determine whether inputs are conservative or best-estimate values.

Provide examples for each application.

5. How does DPC apply the TACO-3 release model for transient power excursions for calculating fission gas release and end-of-life (EOL) rod pressures?
6. What is the maximum differential pressure allowed for the EOL rod pressure analysis and how is this determined? Provide an example.
7. Is the response surface used by BWFC for DNB propagation in BAW-10183P-A applicable to DPC cores?
8. What are the limiting performance criteria for the linear heat generation rate of the fuel during normal operation and anticipated operational occurrences at rod average burnups greater than 40 GWd/MTU? Provide an example.

II. Technical Staff Qualifications And Training That Includes Maintaining Continuity III.

Quality Assurance IV.

Interaction With B&W And Future Plans ENCLOSURE

Duke Power Company Catawba Nuclear Station McGuire Nuclear Station Oconee Nuclear Station cc:

Dr. John M. Barry Mr. Ed Burchfield Mecklenburg County Compliance Department of Environmental Duke Power Company Protection Oconee Nuclear Site 700 N Tryon Street P. 0. Box 1439 Charlotte, North Carolina 29202 Seneca, South Carolina 29679 County Manager of Mecklenburg County Mr. Robert B. Borsum 720 East Fourth Street Babcock & Wilcox Charlotte, North Carolina 28202 Nuclear Power Division Suite 525 Mr. J. E. Snyder 1700 Rockville Pike Regulatory Compliance Manager Rockville, Maryland 20852 Duke Power Company McGuire Nuclear Site Manager, LIS 12700 Hagers Ferry Road NUS Corporation Huntersville, North Carolina 28078 2650 McCormick Drive, 3rd Floor Clearwater, Flordia 34619-1035 Senior Resident Inspector c/o U.S. Nuclear Regulatory Senior Resident Inspector Commission U.S. Nuclear Regulatory Commissions 12700 Hagers Ferry Road Route 2, Box 610 Huntersville, North Carolina 28078 Seneca, South Carolina 29678 Mr. Dayne H. Brown, Director Mr. David L. Rehn Department of Environmental Vice President, Catawba Site Health and Natural Resources Duke Power Company Division of Radiation Protection 4800 Concord Road P. 0. Box 27687 York, South Carolina 29745 Raleigh, North Carolina 27611 Mr. T. C. McMeekin County Supervisor of Oconee County Vice President, McGuire Site Walhalla, South Carolina 27621 Duke Power Company 12700 Hagers Ferry Road Mr. J. W. Hampton Huntersville, North Carolina 28078 Vice President, Oconee Site Duke Power Company Elaine Wathen, Lead REP Planner P. 0. Box 1439 Division of Emergency Management Seneca, South Carolina 29679 116 West Jones Street Raleigh, North Carolina 27603-1335

0 Duke Power Company Catawba Nuclear Station McGuire Nuclear Station Oconee Nuclear Station cc:

Mr. Z. L. Taylor Regulatory Compliance Manager North Carolina Electric Membership Duke Power Company Corporation 4800 Concord Road P. 0. Box 27306 York, South Carolina 29745 Raleigh, North Carolina 27611 A. V. Carr, Esquire Saluda River Electric Cooperative, Duke Power Company Inc.

422 South Church Street P. 0. Box 929 Charlotte, North Carolina 28242 Laurens, South Carolina 29360 J. Michael McGarry, III, Esquire Senior Resident Inspector Winston and Strawn 4830 Concord Road 1400 L Street, NW.

York, South Carolina 29745 Washington, DC 20005 Regional Administrator, Region II North Carolina Municipal Power U.S. Nuclear Regulatory Commission, Agency Number 1 101 Marietta Street, NW Suite 2900 1427 Meadowwood Boulevard Atlanta, Georgia 30323 P. 0. Box 29513 Raleigh, North Carolina 27626 Max Batavia, Chief Bureau of Radiological Health Mr. T. Richard Puryear South Carolina Department of Health Nuclear Technical Services Manager and Environmental Control Westinghouse Electric Corporation 2600 Bull Street Carolinas District Columbia, South Carolina 29201 2709 Water Ridge Parkway, Suite 430 Charlotte, North Carolina 28217 Ms. Karen E. Long Assistant Attorney General County Manager of York County North Carolina Department of Justice York County Courthouse P. 0. Box 629 York, South Carolina 29745 Raleigh, North Carolina 27602 Richard P. Wilson, Esquire Mr. G. A. Copp Assistant Attorney General Licensing -

EC050 S.C. Attorney General's Office Duke Power Company P. 0. Box 11549 526 South Church Street Columbia, South Carolina 29211 Charlotte, North Carolina 28242-0001 Piedmont Municipal Power Agency 121 Village Drive Greer, South Carolina 29651