FSAR CHAPTER 4 - PRIMARY COOLANT SYSTEM TABLE 4-18 Revision 21 Page 1 of 3 PRIMARY COOLANT SYSTEM PRESERVICE QUALITY ASSURANCE PROGRAM

1.

Reactor Vessel Forgings Flanges UT, MT Studs UT, MT Cladding UT(a), PT(a)

Nozzles UT, MT Plates UT(b), MT Cladding UT(a), PT(a)

Welds Main Seams RT, MT CRD Head Nozzle Connection PT(a)

Instrumentation Nozzles PT(a)

Main Nozzles RT, MT Cladding UT(a), PT Nozzle Safe Ends RT, MT Vessel Support Buildup UT(a), MT All Welds - After Hydrostatic Test MT

2.

Steam Generator Tube Sheet Forging UT, MT Cladding UT(a), PT(a)

Primary Head Plate UT(b), MT Cladding UT(a), PT(a)

Secondary Shell and Head Plates UT(b), MT Tubes UT, ET Nozzles (Forgings)

UT, MT Studs UT, MT

FSAR CHAPTER 4 - PRIMARY COOLANT SYSTEM TABLE 4-18 Revision 21 Page 2 of 3 PRIMARY COOLANT SYSTEM PRESERVICE QUALITY ASSURANCE PROGRAM Welds Shell, Longitudinal RT, MT Shell, Circumferential RT, MT, UT Cladding UT(a), PT Nozzles to Shell RT, MT, UT, PT Tube-to-Tube Sheet PT, GT(a)

Instrument Connections MT, RT Temporary Attachments After Removal MT All Welds - After Hydrostatic Test MT Nozzle Safe Ends RT, MT

3.

Pressurizer Heads Plates UT(b), MT Cladding UT(a), PT(a)

Shell Plates UT(b), MT Cladding UT(a), PT(a)

Heaters Tubing UT, PT Centering of Elements RT(a)

Nozzle UT, PT, MT Studs UT, MT Welds Shell, Longitudinal RT, MT Shell, Circumferential RT, MT Cladding UT(a), PT Nozzles RT, MT Nozzle Safe Ends RT, MT, PT Instrument Connections PT Support Skirt RT, MT Temporary Attachments After Removal MT All Welds After Hydrostatic Test MT

FSAR CHAPTER 4 - PRIMARY COOLANT SYSTEM TABLE 4-18 Revision 21 Page 3 of 3 PRIMARY COOLANT SYSTEM PRESERVICE QUALITY ASSURANCE PROGRAM (a) Above code (ASME B&PV Code,Section III, 1965, W65a).

(b) A 100% volumetric ultrasonic test of plate for both two-directional shear wave and longitudinal wave is performed. The ASME Code requires that Section III, Class A plate receive only a longitudinal wave ultrasonic test on a 9-inch by 9-inch grid.

The 100% volumetric ultrasonic test assures that plate used in the primary system is of the highest quality.

4.

Pumps Castings RT, PT Forgings UT, PT Welds Circumferential RT, PT Instrument Connections PT All Welds After Hydrostatic Test PT

5.

Piping Fittings (Mill Clad Plate)

UT, PT(a)

Pipe (Mill Clad Plate)

UT, PT(a)

Welds Longitudinal RT, MT Circumferential RT, MT Nozzle to Run Pipe RT, MT (or PT)

Instrument Connections PT Cladding PT RT - Radiographic MT-Magnetic Particle UT - Ultrasonic ET - Eddy Current PT - Dye Penetrant GT - Gas Leak Test