MONTHYEARML23285A0922023-10-12012 October 2023 Inservice Testing Program for Pumps and Valves Sixth Interval Update and Associated Relief and Alternative Requests ML23244A0142023-08-30030 August 2023 Inservice Inspection Owner'S Activity Report ML23073A1822023-03-14014 March 2023 Inservice Inspection Owner'S Activity Report (OAR) ML22108A2242022-04-14014 April 2022 Steam Generator Tube Inspection Report for the Fall 2021 Refueling Outage ML22048B8192022-02-17017 February 2022 Inservice Inspection Owner'S Activity Report (OAR) ML21243A3132021-08-27027 August 2021 Steam Generating Tube Inspection Report for the Spring 2021 Refueling Outage ML21235A0912021-08-23023 August 2021 Inservice Inspection Owner'S Activity Report Ended on June 1, 2021 ML20304A1542020-08-25025 August 2020 Inservice Inspection Owner'S Activity Report ML20101H3072020-03-26026 March 2020 Annual Changes, Tests, and Experiments Report Regulatory Commitment Evaluation Report ML20087H0092020-03-11011 March 2020 Steam Generator Tube Inspection Report for the Fall 2019 Refueling Outage ML20136A2532020-02-18018 February 2020 Submittal of Inservice Inspection Owner'S Activity Report for Surry Unit 1 Refueling Outgae s1R29 Which Ended on 11/29/2019 ML19331A9162019-11-27027 November 2019 ASME Section XI Inservice Inspection Program Proposed Alternative Request S2-15-ISI-05 to Use a Mechanical Clamping Device for a One-Inch Main Steam Line Pipe Repair ML19071A1072019-03-0404 March 2019 Inservice Inspection Owner'S Activity Report ML18331A1622018-11-19019 November 2018 Steam Generator Tube Inspection Report for the Spring 2018 Refueling Outage ML18229A0622018-08-10010 August 2018 Inservice Inspection Owner'S Activity Report ML17251A8952017-08-31031 August 2017 Proposed Alternative to ASME Section XI Requirements for Repair/Replacement of Buried Circulating and Service Water Class 3 Piping with Carbon Fiber Reinforced Polymer Response to Request for Additional Information ML17261A1872017-08-29029 August 2017 Inservice Inspection Owner'S Activity Report ML17121A3782017-04-24024 April 2017 Submittal of Steam Generator Tube Inspection Report for the Fall 2016 Refueling Outage ML17040A4072017-02-0606 February 2017 Inservice Inspection Owner'S Activity Report 1-5-1-2, for Refueling Outage S1R27, First Period of the Fifth ISI Interval ML16355A3462016-12-14014 December 2016 Proposed Alternative to ASME Section XI Requirements for Repair/Replacement of Circulating and Service Water Class 3 Buried Piping in Accordance with 10 CFR 50.55a(Z)(1) ML16141A1172016-05-10010 May 2016 Inspection Report for the Fall 2015 Refueling Outage ML16131A6352016-05-0505 May 2016 ASME Section XI Inservice Inspection Program Relief Requests for Limited Coverage Examinations Preformed in the Fourth 10-Year Insevice Inspection Interval ML16081A1672016-03-0101 March 2016 Inservice Inspection Owner'S Activity Report ML15324A0142015-11-0606 November 2015 Steam Generator Tube Inspection Report for the Spring 2015 Refueling Outage ML15293A1242015-10-0909 October 2015 ASME Section XI Inservice Inspection Program Relief Requests for Limited Coverage Examinations Performed in the Fourth 10-Year Inservice Inspection Interval ML15224B3602015-07-31031 July 2015 Inservice Inspection Owner'S Activity Report (OAR) ML14335A6062014-11-19019 November 2014 Response to Request for Additional Information Re 2013 Steam Generator Inservice Inspection Report ML14294A4492014-10-16016 October 2014 Steam Generator Tube Inservice Inspection Report for the Spring 2014 Refueling Outage ML14216A3452014-07-24024 July 2014 Inservice Inspection Owner'S Activity Report ML14133A0062014-05-0707 May 2014 Fifth 10-Year Interval Inservice Inspection Program and Alternative Requests ML14135A3652014-05-0606 May 2014 Steam Generator Tube Inspection Report for the Fall 2013 Refueling Outage ML14056A1942014-02-18018 February 2014 Inservice Inspection Owner'S Activity Report ML13336A1422013-11-26026 November 2013 Fifth 10-Year Interval Inservice Inspection Program and Alternative Requests ML13149A2292013-05-10010 May 2013 Steam Generator Tube Inservice Inspection Report for the Fall 2012 Refueling Outage ML13128A1042013-05-0101 May 2013 Inservice Testing Program for Pumps and Valves Fifth Ten Year Interval Update and Associated Relief Requests ML13056A4122013-02-15015 February 2013 Inservice Inspection Owner'S Activity Report (OAR) ML12321A0472012-10-30030 October 2012 Steam Generator Tube Inservice Inspection Report for the Spring 2012 Refueling Outage ML12242A3472012-08-16016 August 2012 Inservice Inspection Owner'S Activity Report (OAR) ML11291A0582011-10-0505 October 2011 Steam Generator Tube Inservice Inspection Report for the 2011 Refueling Outrage ML11264A0362011-09-0606 September 2011 Inservice Inspection Owner'S Activity Report (OAR) ML11154A1012011-05-24024 May 2011 Steam Generator Tube Inservice Inspection Report for the 2010 Refueling Outage ML1130802582011-02-21021 February 2011 Inservice Inspection Owner'S Activity Report ML1015305332010-05-24024 May 2010 Steam Generator Tube Inservice Inspection Report for 2009 Refueling Outage ML1006804222010-02-25025 February 2010 Inservice Inspection Owner'S Activity Report (OAR) ML0932002072009-11-0404 November 2009 Steam Generator Tube Inservice Inspection Report for 2009 Refueling Outage ML0923002302009-08-0707 August 2009 Inservice Inspection Owner'S Activity Report ML0900601112008-11-14014 November 2008 Steam Generator Tube Inservice Inspection Report for the 2008 Refueling Outage ML0824603182008-08-12012 August 2008 Inservice Inspection Owner'S Activity Report ML0815602162008-05-21021 May 2008 Steam Generator Tube Inservice Inspection Report for the 2007 Refueling Outage ML0806406572008-02-22022 February 2008 Inservice Inspection Owner'S Activity Report (Form OAR-1), Refueling Outage S1R21, Second Period of the Fourth Ten-Year ISI Interval 2023-08-30
[Table view] Category:Letter
MONTHYEARIR 05000280/20244012024-02-0606 February 2024 Security Baseline Inspection Report 05000280/2024401, 05000281/2024401 and 07200002/2024401 IR 05000280/20230102024-01-18018 January 2024 Age Related Degradation Inspection Report 05000280-2023010 and 05000281-2023010 ML23312A1922024-01-18018 January 2024 Issuance of Amendment Nos. 316 & 316 Regarding a Risk Informed Approach for Tornado Classification of the Fuel Handling Trolley Support Structure ML24003A9022024-01-0303 January 2024 Stations, Units 1 and 2, Emergency Plan Revision - Relocation of the Technical Support Center (TSC) - Editorial Correction IR 05000280/20233012023-12-28028 December 2023 NRC Operator License Examination Report 05000280/2023301 and 05000281/2023301 ML23283A3052023-12-20020 December 2023 Review of Appendix F to DOM-NAF2, Qualification of the Framatome ORFEO-GAIA and ORFEO-NMGRID CHF Correlations in the Dominion Energy VIPRE-D Computer Code (EPID L-2022-LLT-0003) (Nonproprietary) ML23352A3692023-12-18018 December 2023 Associated Independent Spent Fuel Storage Installation, Revision to Emergency Plan Report of Change ML23334A2342023-11-30030 November 2023 Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation ML23242A2292023-11-0707 November 2023 Issuance of Amendment Nos. 315 and 315, Regarding Emergency Procedure Relocation of the Technical Support Center ML23200A2622023-11-0202 November 2023 Issuance of Amendment Nos. 314 and 314, Regarding Technical Specification and Spent Fuel Pool Criticality Change IR 05000280/20230032023-10-25025 October 2023 Integrated Inspection Report 05000280/2023003 and 05000281/2023003 ML23286A0372023-10-13013 October 2023 Annual Submittal of Technical Specifications Bases Changes Pursuant to Technical Specification 6.4.J ML23285A0922023-10-12012 October 2023 Inservice Testing Program for Pumps and Valves Sixth Interval Update and Associated Relief and Alternative Requests ML23277A1172023-10-0303 October 2023 Operator Licensing Examination Approval 05000280/2023301 and 05000281/2023301 ML23230A0502023-10-0202 October 2023 5 of the Quality Assurance Topical Report - Review of Program Changes ML23256A2672023-09-21021 September 2023 Review of the Fall 2022 Steam Generator Tube Inspection Report ML23244A2352023-09-18018 September 2023 Request to Use a Subsequent Edition of the ASME Code, Section XI ML23230A0012023-09-15015 September 2023 Request to Use a Provision of a Previous Edition of the ASME Boiler and Pressure Vessel Code, Section XI, for Non-Destructive Examinations IR 05000280/20220042023-09-0101 September 2023 Reissue - Surry Power Station - Integrated Inspection Report 05000280/2022004 and 05000281/2022004 ML23244A0142023-08-30030 August 2023 Inservice Inspection Owner'S Activity Report IR 05000280/20230052023-08-23023 August 2023 Updated Inspection Plan for Surry Power Station, Units 1 and 2 (Report 05000280/2023005 and 05000281/2023005) ML23226A1862023-08-10010 August 2023 Proposed License Amendment Request - Reclassification of Regulatory Guide 1.97 Variable for Low Head Safety Injection Flow Instrumentation ML23220A1492023-08-0707 August 2023 Independent Spent Fuel Storage Installation - Submittal of Cask Registrations for Spent Fuel Storage ML23220A1482023-08-0707 August 2023 Proposed Emergency Plan Revision - Relocation of the Technical Support Center (TSC) Response to Request for Additional Information IR 05000280/20230022023-08-0404 August 2023 Integrated Inspection Report 05000280/2023002 and 05000281/2023002 ML23208A0922023-07-26026 July 2023 Request for Approval of Appendix F of Fleet Report DOM-NAF-2-P Qualification of Framatome ORFEO-GAIA and OORFE-NMGRID CHF Correlations in the Dominion Energy Vipre-D Computer Code Response ML23207A1102023-07-26026 July 2023 NRC Regulatory Issues Summary 2023-01 Preparation and Scheduling of Operator Licensing Examinations ML23198A0322023-07-18018 July 2023 Regulatory Audit Report Regarding Review of License Amendment to Modify Emergency Plan Staff Augmentation Times ML23193A9382023-07-18018 July 2023 Closeout of Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at Pressurized-Water Reactors ML23173A0602023-07-11011 July 2023 Audit Summary for License Amendment Request Revision of the Emergency Plan to Support Relocation of the Technical Support Center ML23136B1392023-06-29029 June 2023 Issuance of Amendment No. 313 Administrative Changes to Subsequent Renewed Operating Licenses and Technical Specifications ML23178A1682023-06-26026 June 2023 2022 Annual Report of Emergency Core Cooling System (ECCS) Model Changes Pursuant to the Requirements of 10 CFR 50.46 ML23152A0432023-06-22022 June 2023 Audit Plan License Amendment Requests to Change Emergency Plan Staff Augmentation Times ML23153A1732023-06-16016 June 2023 Correction to Amendment Nos. 346 & 286 Millstone, 294 & 277 North Anna, 311 & 311 Surry, and 225 Summer to Revise Technical Specifications to Adopt TSTF-554,Rev Reactor Coolant Leakage Requirement ML23163A2352023-06-12012 June 2023 Request to Use a Later Edition of the ASME Boiler and Pressure Vessel Code, Section XI, for the SPS Sixth Inservice Inspection (Isi) Intervals and VCSNS Fifth ISI Interval ML23151A6612023-05-31031 May 2023 ES-2.1-1, Surry 2023-301 Corporate Notification Letter (Revised) ML23167B0072023-05-31031 May 2023 Proposed Emergency Plan Revision - Relocation of the Technical Support Center (TSC) Supplemental Information - LOCA Dose Calculation Summary ML23117A0952023-05-10010 May 2023 Audit Plan License Amendment Request to Support Relocation of the Technical Support Center ML23130A3742023-05-10010 May 2023 Request to Delay NRC Intial Licensing Examination 2024-02-06
[Table view] |
Text
VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 Juiy 31, 2015 United States Nuclear Regulatory Commission Serial No.15-373 Attention: Document Control Desk SPS-LIC/CGL R0 Washington, DC 20555-0001 Docket No. 50-280 License No. DPR-32 VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNIT 1 INSERVICE INSPECTION OWNER'S ACTIVITY REPORT (OAR)
In accordance with the requirements of ASME Code Case N-532-5, Virginia Electric and Power Company (Dominion) submits the Inservice Inspection (ISI) Owner's Activity Report (Form OAR-I) for the Surry Unit I refueling outage S1R26, which ended on May 27, 2015. This document addresses the reporting requirements for Surry Unit I for the portion of the third period in the fourth ten-year ISI interval from November 21, 2013 to October 13, 2014 and through the duration of the first refueling outage of the first period in the fifth ten-year inservice inspection interval. In our December 9, 2013 letter (Serial No.13-639), Revised Relief Request SPT-003 stated that the Surry Unit I fourth ISI interval was being extended to October 13, 2014, and our November 26, 2013 letter (Serial No.13-611) identified the fifth ISI interval start date as December 14, 2013.
If you have any questions concerning this information, please contact Mrs. Candee G. Lovett at (757) 365-2178.
Douglas C. L13wr~nce Director Station Safety & Licensing Surry Power Station
Attachment:
Owner's Activity Report (Form OAR-I), Surry Unit I Refueling Outage $1R26, First Period of the Fifth ISI Interval Commitments made in this letter: None 1 LVj47
Serial No.: 15-373 Docket No.: 50-280 Page 2 of 2 cc: U.S. Nuclear Regulatory Commission Region II Marquis One Tower 245 Peachtree Center Avenue NE Suite 1200 Atlanta, Georgia 30303-1257 NRC Senior Resident Inspector Surry Power Station Ms. K. Cotton Gross NRC Project Manager - Surry
-U. S. Nuclear Regulatory Commission One White Flint North Mail Stop 08 G9A 11555 Rockville Pike Rockville, Maryland 20852-2738 Dr. V. Sreenivas NRC Project Manager - North Anna U. S. Nuclear Regulatory Commission
,;One White Flint North
- Mail Stop 08 G9A 11555 Rockville Pike Rockville, Maryland 20852-2738 Mr. R. A. Smith Authorized Nuclear Inspector Surry Power Station
Serial No.: 15-373 Docket No.: 50-280 ATTACHMENT OWNER'S ACTIVITY REPORT (FORM OAR-I),
SURRY UNIT 1 REFUELING OUTAGE $1 R26, FIRST PERIOD OF THE FIFTH ISI INTERVAL VIRGINIA ELECTRIC AND POWER COMPANY (DOMINION)
CASE CASES OF ASME BOILER AND PRESSURE VESSEL CODE N-532-5 FORM OAR-i OWNER'S ACTIVITY REPORT R~nnrt Niimh~r qtlrrv VA 7*4RRq
- nnrl gq[TN Hnn fqlnncl
£11rrv Pnwor qf*finn Plant ~rIrru Prn,,,r-~r ~1~linn ~c7fl I-Inn kIn,1 Pnrri C~Irni VA 9~RR~
I Init Nn 1 Commercial service date 12/22/1972 Refueling outage no. S1R26 (if applicable)
Current inspection interval 5th (1st, 2nd, 3rd, 4th, other)
Current inspection period 1st (1st, 2nd, 3rd)
Edition and Addenda of Section XI applicable to the inspection plans 4th Tnf_ 1qqR F-2000* A and Sth Int. 2004 F Date and revision of inspection plans Surry Unit 1, 4th Int. ISI Plan, Rev 12, Aug. 25, 2014 / 5th Int. ISI Plan, Revision 1, Mar. 12, 2015 Edition and Addenda of Section XI applicable to repair/replacement activities, if different than the inspection plans N/A Code Cases used for inspection and evaluation: N-586-1 (if applicable, including cases modified by Case N-532 and later revisions)
CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in this report are correct; (b) the examinations and tests meet the Inspection Plan as required by the ASME Code, Section XL and (c) the repair/replacement activities and evaluations supporting the completion of $1R26 conform to the/eqi, ments of Section XI. (refueling outage number)
Signed J'ir] ..... / 1S1Progam Owner Date y/2-6 /I5 "
~Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and employed by HSB-GS of Hartford, CT have inspected the items described in this Owner's Activity Report, and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair/replacement activities and evaluation described in this report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
Commissions NB-7933 NS, IS; VA883(R)
Inspector's Signature National Board, State, Province, and Endorsements Date
/ /
Page 1 of 2 CASE CASES OF ASME BOILER AND PRESSURE VESSEL CODE N- 25 FORM OAR-i OWNER'S ACTIVITY REPORT Table 1 Items with Flaws or Relevant Conditions That Required Evaluation for Continued Service Examination Category and Item Number JjItem Description Evaluation Description None Note: There were no items requiring analytical evaluation to include on this table for interval 4 or interval 5 during this reporting cycle.
Page 2 of.2 CASE N-532-5 CASES OASME BOILER' ANDPRSSREVESSE COEPR FORM OAR-i OWNER'S ACTIV~~Y REPORT Table 2 Abstract of Repair/replacement Activities Required for Continued Service Code Class Item Description Date Repair/Replacement Description of Work Completed Plan Number 1 1-CH-H001 Repair pipe support on line 5/9/2015 2015-086 12"RC-i199-1502 and 2" CH-9-1 502 for
- 2-RC-HCV-1 556B.
I1-SI-H005-1 Repair NDE rejected indications on 5/4/2015 2015-088 integral attachment on line 2" SI-74-1 502 using the guidance of Nuclear Code Case N-586-1.
1 2" RC-56-1502 Replace piping for NDE rejected 5/5/2015 2015-082 indications.
21-RS-MEJ-2A-PIPE Weld repair expansion joint for though- 5/13/2015 2015-098 wall leak.
21 -RS-MEJ-2B-PIPE Replace expansion joint for 5/20/2015 2015-095 through-wall leak.
301 -SW-269 Replace pipe tee upstream of 11/24/2014 2014-126 01-SW-269 on line number 2" WS-171-9107.
301-SW-P-lOB Replace discharge spool piece for 6/17/2014 2014-097 through-wall leak 32" WS-314-9107 Repair fiberglass piping for through- 5/28/2015 2015-113 wall leak.
348" WC-2-10 Weld repair piping for through-wall 4/28/2015 2015-079 corrosion.
396" WC-3-10 Weld repair piping for through-wall 4/28/2015 201 5-080 corrosion.
Note: There were no interval 4 items to be included on this table during this reporting cycle.