1 LaSalle Environmental Audit Response to Request for Additional Information Index #:

044 RAI #: GW-02 Category: Water Resources Statement of Question:

Provide currently available 2015 tritium concentration data from monitor wells, used to monitor the cleanup of the spill from the Unit 1 Cycled Condensate Tank.

Response

Currently available 2015 results for the Unit 1 Cycled Condensate Storage Tank remediation monitoring are being provided as Attachment 1 to this RAI response.

List of Attachments

1. Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring

RAI # GW-02 ATTACHMENT 1

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 1 of 31 Date/Time pCi/L 1/13/15 8:30 8.17E-07 8.17E+02 1/26/15 11:28 9.17E-07 9.17E+02 2/7/15 11:19 1.30E-06 1.30E+03 2/21/15 11:50 1.30E-06 1.30E+03 3/6/15 9:00 9.64E-07 9.64E+02 3/11/15 7:50 9.94E-07 9.94E+02 3/26/15 10:16 9.17E-07 9.17E+02 3/31/15 7:55 8.23E-07 8.23E+02 4/28/15 8:10 8.95E-07 8.95E+02 5/12/15 7:25 8.76E-07 8.76E+02 5/29/15 10:35 8.75E-07 8.75E+02 6/9/15 8:30 8.82E-07 8.82E+02 Storm Drain Oil Sep Pit Compositor Sample Results

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 2 of 31 SW-LS-101 Sample Results Exelon ENV LLD Water Level Date/Time Activity (pCi/L)

(ft) 3/12/15 13:30 8.29E+02 699.5

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 3 of 31 SW-LS-102 Sample Results Exelon ENV LLD Water Level Date/Time Activity (pCi/L)

(ft) 3/11/15 11:00 8.29E+02 699.5

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 4 of 31 SW-LS-103 Sample Results Exelon ENV LLD Water Level Date/Time Activity (pCi/L)

(ft) 3/11/15 11:10 8.29E+02 699.5

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 5 of 31 Exelon ENV LLD Water Level Date/Time Activity (pCi/L)

(ft) 3/11/15 9:05 8.29E+02 699.5 SW-LS-106 Sample Results

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 6 of 31 HP-2 Sample Results Exelon ENV LLD Date/Time Activity (pCi/L) 1/31/15 10:15 8.15E+02

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 7 of 31 HP-5 Sample Results Exelon ENV LLD Date/Time Activity (pCi/L) 1/31/15 10:40 8.15E+02

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 8 of 31 HP-7 Sample Results Exelon ENV LLD Date/Time Activity (pCi/L) 1/31/15 10:55 8.15E+02

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 9 of 31 HP-10 Sample Results Exelon ENV LLD Date/Time Activity (pCi/L) 1/31/15 10:50 8.15E+02

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 10 of31 MW-LS-104s Sample Results Exelon ENV LLD Water Level Well Bottom Level Water Column Date/Time Activity (pCi/L)

(ft)

(ft)

(ft) 1/13/15 9:05 2.96E+04 9.3 16.8 7.5 1/27/15 8:05 2.75E+04 9.0 17.0 8.0 2/7/15 11:41 2.79E+04 8.9 16.9 8.0 2/21/15 10:58 2.93E+04 9.2 17.1 7.9 3/6/15 11:00 2.86E+04 9.5 17.1 7.6 3/11/15 8:10 2.98E+04 9.3 17.2 7.9 3/31/15 10:15 2.53E+04 9.0 17.0 8.0 4/14/15 10:45 1.91E+04 8.7 17.0 8.3 4/28/15 7:40 2.14E+04 8.7 17.0 8.3 5/12/15 8:45 2.18E+04 8.4 17.0 8.6 5/29/15 11:25 2.61E+04 8.2 17.0 8.8 6/9/15 9:00 1.92E+04 7.0 17.0 10.0

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 11 of 31 MW-LS-105s Sample Result Exelon ENV LLD Date/Time Activity (pCi/L) 1/31/15 11:25 8.15E+02

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 12 of 31 MW-LS-106s Sample Results Exelon ENV LLD Water Level Well Bottom Level Water Column Date/Time Activity (pCi/L)

(ft)

(ft)

(ft) 3/12/15 13:15 8.29E+02 6

15.7 9.7

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 13 of 31 MW-LS-107s Sample Results Exelon ENV LLD Water Level Well Bottom Level Water Column Date/Time Activity (pCi/L)

(ft)

(ft)

(ft) 1/31/15 11:05 8.15E+02

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 14 of 31 MW-LS-111s Sample Results Exelon ENV LLD Water Level Well Bottom Level Water Column Date/Time Activity (pCi/L)

(ft)

(ft)

(ft) 3/11/15 10:50 8.29E-07 0

13.9 13.9

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 15 of 31 TW-LS-115s Sample Results Exelon ENV LLD Water Level Well Bottom Level Water Column Date/Time Activity (pCi/L)

(ft)

(ft)

(ft) 2/3/15 13:35 8.18E+02 2/21/15 10:34 1.30E+03 8.8 18.1 9.3

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 16 of 31 TW-LS-116s Sample Results Exelon ENV LLD Exelon ENV LLD Water Level Well Bottom Level Water Column Date/Time Activity (pCi/L)

Activity (pCi/L)

(ft)

(ft)

(ft) 1/13/15 8:55 9.21E+03 9.21E+03 10.30 17.80 7.50 1/26/15 13:35 8.06E+03 8.06E+12 9.30 17.80 8.50 2/3/15 13:20 8.24E+03 8.24E+12 2/7/15 11:33 9.44E+03 9.44E+12 9.50 17.90 8.40 2/21/15 10:55 9.24E+03 9.24E+12 9.00 17.90 8.90 3/6/15 10:20 7.89E+03 7.89E+12 9.00 17.90 8.90 3/26/15 10:31 8.66E+03 8.66E+12 8.70 17.90 9.20 3/31/15 8:15 1.24E+04 1.24E+13 8.70 17.90 9.20 4/14/15 11:00 7.70E+03 7.70E+12 9.30 17.90 8.60 5/12/15 7:55 1.07E+04 1.07E+13 9.00 18.00 9.00 5/29/15 10:55 1.19E+04 1.19E+13 8.40 17.80 9.40 6/9/15 8:56 1.14E+04 1.14E+13 8.80 17.90 9.10

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 17 of 31 TW-LS-118s Sample Results Exelon ENV LLD Water Level Well Bottom Level Water Column Date/Time Activity (pCi/L)

(ft)

(ft)

(ft) 1/13/15 8:45 2.27E+04 9.2 18.1 8.9 1/27/15 7:45 2.54E+04 9.3 18.3 9.0 2/3/15 13:25 2.47E+04 2/7/15 11:28 2.46E+04 9.1 18.4 9.3 2/21/15 10:50 2.60E+04 9.2 18.5 9.3 3/6/15 10:10 2.33E+04 9.3 18.4 9.1 3/26/15 10:27 2.36E+04 9.0 18.3 9.3 3/31/15 8:10 2.63E+04 9.0 18.4 9.4 4/14/15 11:05 2.68E+04 8.9 18.3 9.4 5/12/15 7:45 2.32E+04 8.8 18.3 9.5 5/29/15 10:50 1.90E+04 8.8 17.2 8.4 6/9/15 8:49 1.72E+04 8.8 17.5 8.7

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 18 of 31 TW-LS-119s Sample Results Exelon ENV LLD Water Level Well Bottom Level Water Column Date/Time Activity (pCi/L)

(ft)

(ft)

(ft) 1/13/15 8:15 8.17E+02 6.0 13.8 7.8 1/26/15 13:20 9.17E+11 5.8 14.1 8.3 2/3/15 13:10 8.18E+11 2/7/15 10:48 1.30E+12 5.4 14.1 8.7 2/21/15 10:20 1.30E+12 5.5 14.1 8.6 3/6/15 13:30 9.16E+11 6.0 14.3 8.3 3/31/15 10:20 8.23E+11 5.1 14.0 8.9 4/14/15 12:53 9.20E+11 5.1 14.1 9.0 4/28/15 9:10 8.95E+11 5.0 14.1 9.1 5/12/15 8:15 8.76E+11 4.6 14.0 9.4 5/29/15 10:45 8.75E+11 4.4 14.0 9.6 6/9/15 9:17 8.82E+11 4.8 14.0 9.2

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 19 of 31 TW-LS-120s Sample Results Exelon ENV LLD Water Level Well Bottom Level Water Column Date/Time Activity (pCi/L)

(ft)

(ft)

(ft) 1/13/15 7:45 8.17E+02 6.3 11.3 5.0 1/26/15 13:20 9.17E-07 9.17E+02 6.1 11.3 5.2 2/3/15 13:10 8.18E-07 8.18E+02 2/7/15 10:48 1.30E-06 1.30E+03 5.8 11.3 5.5 2/21/15 10:25 1.30E-06 1.30E+03 5.9 11.3 5.4 3/6/15 10:25 9.64E-07 9.64E+02 6.6 11.6 5.0 3/26/15 11:03 9.17E-07 9.17E+02 6.1 11.3 5.2 3/31/15 10:35 8.23E-07 8.23E+02 6.1 11.4 5.3 4/14/15 12:59 9.20E-07 9.20E+02 5.9 11.3 5.4 4/28/15 9:15 8.95E-07 8.95E+02 5.9 11.4 5.5 5/12/15 8:25 8.76E-07 8.76E+02 5.5 11.5 6.0 5/29/15 11:15 8.75E-07 8.75E+02 5.4 11.4 6.0 6/9/15 9:22 8.82E-07 8.82E+02 5.0 11.3 6.3

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 20 of 31 TW-LS-121s Sample Results Exelon ENV LLD Water Level Well Bottom Level Water Column Date/Time Activity (pCi/L)

(ft)

(ft)

(ft) 1/13/15 8:35 8.17E+02 8.3 11.6 3.3 1/27/15 7:35 9.17E+11 8.3 11.7 3.4 2/3/15 13:45 8.18E+11 2/7/15 11:06 1.30E+12 8.0 12.0 4.0 2/21/15 10:36 1.30E+12 8.1 11.8 3.7 3/6/15 9:00 9.64E+11 8.5 11.9 3.4 3/26/15 10:21 9.17E+11 8.0 11.8 3.8 3/31/15 8:05 8.23E+11 8.2 12.0 3.8 4/14/15 11:15 9.20E+11 7.8 11.8 4.0 4/28/15 8:25 8.95E+11 7.9 11.9 4.0 5/12/15 8:05 8.76E+11 7.4 11.8 4.4 5/29/15 10:45 8.75E+11 7.5 11.8 4.3 6/9/15 8:45 8.82E+11 7.2 11.8 4.6

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 21 of 31 RW-LS-100s Sample Results Exelon ENV LLD Date/Time Activity (pCi/L)

Totalizer 1 Totalizer 2 Discharge Flow (gpm)

Water Discharge Volume (gal)

Activity discharged (pCi)

Activity discharged (Ci) 100s Cumulative Activity discharged (Ci) 101s Cumulative Activity discharged (Ci)

Total Cumulative Activity discharged (Ci) 01/03/15 14:08 5.82E-05 5.82E+04 848526 848526 1.52 2275 5.012E+08 5.01E-04 3.29E-01 6.51E-02 3.94E-01 01/04/15 14:23 5.47E-05 5.47E+04 850801 850801 1.59 1944 4.025E+08 4.03E-04 3.29E-01 6.52E-02 3.94E-01 01/05/15 10:55 5.42E-05 5.42E+04 852745 852745 1.58 1945 3.991E+08 3.99E-04 3.30E-01 6.52E-02 3.95E-01 01/06/15 07:15 5.35E-05 5.35E+04 854690 854690 1.60 2465 4.992E+08 4.99E-04 3.30E-01 6.53E-02 3.95E-01 01/07/15 08:25 5.26E-05 5.26E+04 857155 857155 1.64 2664 5.304E+08 5.30E-04 3.31E-01 6.54E-02 3.96E-01 01/08/15 11:00 5.15E-05 5.15E+04 859819 859819 1.67 2121 4.135E+08 4.13E-04 3.31E-01 6.54E-02 3.96E-01 01/09/15 07:55 4.67E-05 4.67E+04 861940 861940 1.69 3214 5.682E+08 5.68E-04 3.32E-01 6.54E-02 3.97E-01 01/10/15 15:15 4.75E-05 4.75E+04 865154 865154 1.72 2343 4.213E+08 4.21E-04 3.32E-01 6.55E-02 3.97E-01 01/11/15 14:30 4.56E-05 4.56E+04 867497 867497 1.68 2013 3.475E+08 3.47E-04 3.32E-01 6.55E-02 3.98E-01 01/12/15 10:10 4.52E-05 4.52E+04 869510 869510 1.71 2343 4.009E+08 4.01E-04 3.33E-01 6.56E-02 3.98E-01 01/13/15 08:00 4.67E-05 4.67E+04 871853 871753 1.72 2442 4.317E+08 4.32E-04 3.33E-01 6.57E-02 3.99E-01 01/14/15 08:50 4.75E-05 4.75E+04 874295 874295 1.73 2071 3.724E+08 3.72E-04 3.34E-01 6.57E-02 3.99E-01 01/15/15 05:00 4.68E-05 4.68E+04 876366 876366 1.71 2669 4.728E+08 4.73E-04 3.34E-01 6.59E-02 4.00E-01 01/16/15 07:30 4.70E-05 4.70E+04 879035 879035 1.69 3151 5.606E+08 5.61E-04 3.35E-01 6.61E-02 4.01E-01 01/17/15 14:41 4.66E-05 4.66E+04 882186 882186 1.70 2499 4.408E+08 4.41E-04 3.35E-01 6.62E-02 4.01E-01 01/18/15 14:51 4.60E-05 4.60E+04 884685 884685 1.71 2589 4.508E+08 4.51E-04 3.35E-01 6.64E-02 4.02E-01 01/19/15 15:28 4.71E-05 4.71E+04 887274 887274 1.75 1826 3.256E+08 3.26E-04 3.36E-01 6.65E-02 4.02E-01 01/20/15 08:42 4.94E-05 4.94E+04 889100 889100 1.77 2455 4.591E+08 4.59E-04 3.36E-01 6.66E-02 4.03E-01 01/21/15 07:45 4.61E-05 4.61E+04 891555 891555 1.78 2578 4.499E+08 4.50E-04 3.37E-01 6.67E-02 4.03E-01 01/22/15 07:10 4.55E-05 4.55E+04 894133 894133 1.84 2810 4.840E+08 4.84E-04 3.37E-01 6.69E-02 4.04E-01 01/23/15 08:25 4.47E-05 4.47E+04 896943 896943 1.94 3396 5.746E+08 5.75E-04 3.38E-01 6.71E-02 4.05E-01 01/24/15 14:32 4.41E-05 4.41E+04 900339 900339 1.89 2687 4.486E+08 4.49E-04 3.38E-01 6.72E-02 4.05E-01 01/25/15 14:35 4.32E-05 4.32E+04 903026 903026 1.86 1970 3.222E+08 3.22E-04 3.39E-01 6.73E-02 4.06E-01 01/26/15 08:21 4.37E-05 4.37E+04 904996 904996 1.85 2566 4.245E+08 4.24E-04 3.39E-01 6.75E-02 4.06E-01 01/27/15 07:20 4.29E-05 4.29E+04 907562 907562 1.87 2786 4.524E+08 4.52E-04 3.39E-01 6.76E-02 4.07E-01 01/28/15 07:56 3.95E-05 3.95E+04 910348 910348 1.89 2792 4.175E+08 4.17E-04 3.40E-01 6.78E-02 4.08E-01 01/29/15 08:12 3.95E-05 3.95E+04 913140 913140 1.92 2660 3.977E+08 3.98E-04 3.40E-01 6.79E-02 4.08E-01 01/30/15 07:00 3.95E-05 3.95E+04 915800 915800 1.93 3305 4.942E+08 4.94E-04 3.41E-01 6.80E-02 4.09E-01 01/31/15 11:17 4.15E-05 4.15E+04 919105 919105 1.96 2293 3.602E+08 3.60E-04 3.41E-01 6.82E-02 4.09E-01 02/01/15 08:30 4.15E-05 4.15E+04 921398 921398 1.78 5476 8.602E+08 8.60E-04 3.42E-01 6.85E-02 4.10E-01 02/03/15 10:20 4.22E-05 4.22E+04 926874 926874 1.86 2619 4.184E+08 4.18E-04 3.42E-01 6.87E-02 4.11E-01 02/04/15 10:43 4.22E-05 4.22E+04 929493 929493 1.79 2697 4.308E+08 4.31E-04 3.43E-01 6.89E-02 4.12E-01 02/05/15 11:28 4.22E-05 4.22E+04 932190 932190 1.82 5608 8.958E+08 8.96E-04 3.44E-01 6.93E-02 4.13E-01 02/07/15 13:42 4.22E-05 4.22E+04 937798 937798 1.86 2357 3.765E+08 3.77E-04 3.44E-01 6.95E-02 4.14E-01 02/08/15 10:25 4.22E-05 4.22E+04 940155 940155 1.89 2386 3.811E+08 3.81E-04 3.44E-01 6.96E-02 4.14E-01

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 22 of 31 RW-LS-100s Sample Results Exelon ENV LLD Date/Time Activity (pCi/L)

Totalizer 1 Totalizer 2 Discharge Flow (gpm)

Water Discharge Volume (gal)

Activity discharged (pCi)

Activity discharged (Ci) 100s Cumulative Activity discharged (Ci) 101s Cumulative Activity discharged (Ci)

Total Cumulative Activity discharged (Ci) 02/09/15 07:00 4.22E-05 4.22E+04 942541 942541 1.92 2762 4.412E+08 4.41E-04 3.45E-01 6.99E-02 4.15E-01 02/10/15 07:00 3.72E-05 3.72E+04 945303 945303 1.94 2832 3.988E+08 3.99E-04 3.45E-01 7.01E-02 4.15E-01 02/11/15 07:48 3.72E-05 3.72E+04 948135 948135 1.91 3454 4.864E+08 4.86E-04 3.46E-01 7.04E-02 4.16E-01 02/12/15 13:21 3.72E-05 3.72E+04 951589 951589 1.95 2549 3.589E+08 3.59E-04 3.46E-01 7.06E-02 4.17E-01 02/13/15 10:57 3.72E-05 3.72E+04 954138 954138 1.98 2512 3.537E+08 3.54E-04 3.46E-01 7.08E-02 4.17E-01 02/14/15 07:51 3.72E-05 3.72E+04 956650 956650 2.01 2909 4.096E+08 4.10E-04 3.47E-01 7.11E-02 4.18E-01 02/15/15 08:00 3.72E-05 3.72E+04 959559 959559 2.00 2851 4.015E+08 4.01E-04 3.47E-01 7.13E-02 4.19E-01 02/16/15 07:30 3.72E-05 3.72E+04 962410 962410 2.01 2897 4.079E+08 4.08E-04 3.48E-01 7.15E-02 4.19E-01 02/17/15 07:14 3.75E-05 3.75E+04 965307 965307 2.03 547 7.765E+07 7.76E-05 3.48E-01 7.17E-02 4.20E-01 02/18/15 08:10 3.75E-05 3.75E+04 965854 965854 2.19 7

9.937E+05 9.94E-07 3.48E-01 7.19E-02 4.20E-01 02/19/15 07:10 3.75E-05 3.75E+04 965861 965861 1.22 1

1.420E+05 1.42E-07 3.48E-01 7.21E-02 4.20E-01 02/20/15 11:05 3.75E-05 3.75E+04 965862 965862 0.00 2913 4.135E+08 4.14E-04 3.48E-01 7.24E-02 4.21E-01 02/21/15 11:25 3.75E-05 3.75E+04 968775 968775 2.00 2773 3.936E+08 3.94E-04 3.49E-01 7.25E-02 4.21E-01 02/22/15 10:06 3.75E-05 3.75E+04 971548 971548 2.06 2870 4.074E+08 4.07E-04 3.49E-01 7.27E-02 4.22E-01 02/23/15 09:00 3.75E-05 3.75E+04 974418 974418 2.11 3054 4.335E+08 4.34E-04 3.49E-01 7.28E-02 4.22E-01 02/24/15 08:00 3.48E-05 3.48E+04 977472 977472 2.25 3659 4.820E+08 4.82E-04 3.50E-01 7.30E-02 4.23E-01 02/25/15 11:07 3.48E-05 3.48E+04 981131 981131 2.28 2751 3.624E+08 3.62E-04 3.50E-01 7.31E-02 4.23E-01 02/26/15 07:00 3.48E-05 3.48E+04 983882 983882 2.33 4033 5.313E+08 5.31E-04 3.51E-01 7.33E-02 4.24E-01 02/27/15 11:12 3.48E-05 3.48E+04 987915 987915 2.41 3478 4.582E+08 4.58E-04 3.51E-01 7.34E-02 4.25E-01 02/28/15 10:40 3.48E-05 3.48E+04 991393 991393 2.50 3223 4.246E+08 4.25E-04 3.52E-01 7.35E-02 4.25E-01 03/01/15 08:43 3.48E-05 3.48E+04 994616 994616 2.46 4241 5.587E+08 5.59E-04 3.52E-01 7.36E-02 4.26E-01 03/02/15 12:40 3.48E-05 3.48E+04 998857 998857 2.55 3103 4.088E+08 4.09E-04 3.53E-01 7.38E-02 4.26E-01 03/03/15 08:40 3.52E-05 3.52E+04 1001960 1001960 2.62 4020 5.357E+08 5.36E-04 3.53E-01 7.39E-02 4.27E-01 03/04/15 10:10 3.52E-05 3.52E+04 1005980 1005980 2.67 5460 7.275E+08 7.28E-04 3.54E-01 7.40E-02 4.28E-01 03/05/15 19:30 3.52E-05 3.52E+04 1011440 1011440 2.77 2550 3.398E+08 3.40E-04 3.54E-01 7.41E-02 4.28E-01 03/06/15 10:45 3.52E-05 3.52E+04 1013990 1013990 2.81 4870 6.489E+08 6.49E-04 3.55E-01 7.42E-02 4.29E-01 03/07/15 15:13 3.52E-05 3.52E+04 1018860 1018860 2.86 3910 5.210E+08 5.21E-04 3.55E-01 7.43E-02 4.30E-01 03/08/15 14:45 3.52E-05 3.52E+04 1022770 1022770 2.92 2930 3.904E+08 3.90E-04 3.56E-01 7.44E-02 4.30E-01 03/09/15 07:30 3.52E-05 3.52E+04 1025700 1025700 2.91 4120 5.490E+08 5.49E-04 3.56E-01 7.45E-02 4.31E-01 03/10/15 07:00 3.65E-05 3.65E+04 1029820 1029820 2.92 4070 5.623E+08 5.62E-04 3.57E-01 7.46E-02 4.32E-01 03/11/15 07:35 3.65E-05 3.65E+04 1033890 1033890 2.80 1970 2.722E+08 2.72E-04 3.57E-01 7.47E-02 4.32E-01 03/12/15 07:00 3.65E-05 3.65E+04 1035860 1035860 2.70 6840 9.451E+08 9.45E-04 3.58E-01 7.48E-02 4.33E-01 03/13/15 10:40 3.65E-05 3.65E+04 1042700 1042700 2.78 4290 5.927E+08 5.93E-04 3.59E-01 7.49E-02 4.34E-01 03/14/15 13:15 3.65E-05 3.65E+04 1046990 1046990 2.83 3560 4.919E+08 4.92E-04 3.59E-01 7.49E-02 4.34E-01 03/15/15 10:25 3.65E-05 3.65E+04 1050550 1050550 2.75 3630 5.015E+08 5.02E-04 3.60E-01 7.50E-02 4.35E-01

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 23 of 31 RW-LS-100s Sample Results Exelon ENV LLD Date/Time Activity (pCi/L)

Totalizer 1 Totalizer 2 Discharge Flow (gpm)

Water Discharge Volume (gal)

Activity discharged (pCi)

Activity discharged (Ci) 100s Cumulative Activity discharged (Ci) 101s Cumulative Activity discharged (Ci)

Total Cumulative Activity discharged (Ci) 03/16/15 08:05 3.65E-05 3.65E+04 1054180 1054180 2.77 3840 5.306E+08 5.31E-04 3.60E-01 7.51E-02 4.35E-01 03/17/15 07:10 3.51E-05 3.51E+04 1058020 1058020 2.72 4540 6.032E+08 6.03E-04 3.61E-01 7.52E-02 4.36E-01 03/18/15 00:07 3.51E-05 3.51E+04 1062560 1062560 2.61 3940 5.235E+08 5.23E-04 3.61E-01 7.53E-02 4.37E-01 03/19/15 13:25 3.51E-05 3.51E+04 1066500 1066500 2.64 3010 3.999E+08 4.00E-04 3.62E-01 7.54E-02 4.37E-01 03/20/15 08:10 3.51E-05 3.51E+04 1069510 1069510 2.68 6200 8.238E+08 8.24E-04 3.63E-01 7.57E-02 4.38E-01 03/22/15 15:56 3.51E-05 3.51E+04 1075710 1075710 1.79 1870 2.485E+08 2.48E-04 3.63E-01 7.58E-02 4.39E-01 03/23/15 09:00 3.51E-05 3.51E+04 1077580 1077580 1.81 2530 3.362E+08 3.36E-04 3.63E-01 7.59E-02 4.39E-01 03/24/15 09:00 3.30E-05 3.30E+04 1080110 1080110 1.73 2400 2.998E+08 3.00E-04 3.63E-01 7.60E-02 4.39E-01 03/25/15 08:15 3.30E-05 3.30E+04 1082510 1082510 1.65 2490 3.110E+08 3.11E-04 3.64E-01 7.61E-02 4.40E-01 03/26/15 09:00 3.30E-05 3.30E+04 1085000 1085000 1.66 2230 2.786E+08 2.79E-04 3.64E-01 7.63E-02 4.40E-01 03/27/15 07:30 3.30E-05 3.30E+04 1087230 1087230 1.60 3020 3.773E+08 3.77E-04 3.64E-01 7.64E-02 4.41E-01 03/28/15 15:15 3.30E-05 3.30E+04 1090250 1090250 1.57 2260 2.823E+08 2.82E-04 3.65E-01 7.66E-02 4.41E-01 03/29/15 15:35 3.30E-05 3.30E+04 1092510 1092510 1.52 1580 1.974E+08 1.97E-04 3.65E-01 7.67E-02 4.42E-01 03/30/15 08:54 3.30E-05 3.30E+04 1094090 1094090 1.51 2060 2.573E+08 2.57E-04 3.65E-01 7.68E-02 4.42E-01 03/31/15 07:20 3.08E-05 3.08E+04 1096150 1096150 1.48 2410 2.810E+08 2.81E-04 3.65E-01 7.69E-02 4.42E-01 04/01/15 09:15 3.08E-05 3.08E+04 1098560 1098560 1.52 2140 2.495E+08 2.50E-04 3.66E-01 7.71E-02 4.43E-01 04/02/15 08:35 3.08E-05 3.08E+04 1100700 1100700 1.49 2210 2.577E+08 2.58E-04 3.66E-01 7.73E-02 4.43E-01 04/03/15 09:05 3.08E-05 3.08E+04 1102910 1102910 1.49 2630 3.066E+08 3.07E-04 3.66E-01 7.75E-02 4.44E-01 04/04/15 15:00 3.08E-05 3.08E+04 1105540 1105540 1.47 2100 2.448E+08 2.45E-04 3.67E-01 7.76E-02 4.44E-01 04/05/15 14:50 3.08E-05 3.08E+04 1107640 1107640 1.46 1520 1.772E+08 1.77E-04 3.67E-01 7.77E-02 4.44E-01 04/06/15 08:20 3.08E-05 3.08E+04 1109160 1109160 1.42 2050 2.390E+08 2.39E-04 3.67E-01 7.79E-02 4.45E-01 04/07/15 08:20 2.82E-05 2.82E+04 1111210 1111210 1.39 2090 2.231E+08 2.23E-04 3.67E-01 7.81E-02 4.45E-01 04/08/15 07:15 2.82E-05 2.82E+04 1113300 1113300 1.50 2520 2.690E+08 2.69E-04 3.67E-01 7.83E-02 4.46E-01 04/09/15 11:19 2.82E-05 2.82E+04 1115820 1115820 1.48 1900 2.028E+08 2.03E-04 3.68E-01 7.85E-02 4.46E-01 04/10/15 08:25 2.82E-05 2.82E+04 1117720 1117720 1.43 2960 3.160E+08 3.16E-04 3.68E-01 7.87E-02 4.47E-01 04/11/15 14:25 2.82E-05 2.82E+04 1120680 1120680 1.67 2420 2.583E+08 2.58E-04 3.68E-01 7.89E-02 4.47E-01 04/12/15 14:45 2.82E-05 2.82E+04 1123100 1123100 1.64 1890 2.018E+08 2.02E-04 3.68E-01 7.90E-02 4.47E-01 04/13/15 10:10 2.82E-05 2.82E+04 1124990 1124990 1.60 2130 2.274E+08 2.27E-04 3.69E-01 7.92E-02 4.48E-01 04/14/15 08:30 2.59E-05 2.59E+04 1127120 1127120 1.56 2320 2.275E+08 2.27E-04 3.69E-01 7.93E-02 4.48E-01 04/15/15 09:10 2.59E-05 2.59E+04 1129440 1129440 1.54 2050 2.010E+08 2.01E-04 3.69E-01 7.95E-02 4.49E-01 04/16/15 07:20 2.59E-05 2.59E+04 1131490 1131490 1.52 2300 2.255E+08 2.25E-04 3.69E-01 7.97E-02 4.49E-01 04/17/15 08:04 2.59E-05 2.59E+04 1133790 1133790 1.52 3180 3.118E+08 3.12E-04 3.70E-01 8.00E-02 4.50E-01 04/18/15 18:40 2.59E-05 2.59E+04 1136970 1136970 1.51 1770 1.735E+08 1.74E-04 3.70E-01 8.01E-02 4.50E-01 04/19/15 14:30 2.59E-05 2.59E+04 1138740 1138740 1.50 1560 1.529E+08 1.53E-04 3.70E-01 8.03E-02 4.50E-01 04/20/15 08:00 2.59E-05 2.59E+04 1140300 1140300 1.44 2250 2.206E+08 2.21E-04 3.70E-01 8.05E-02 4.51E-01

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 24 of 31 RW-LS-100s Sample Results Exelon ENV LLD Date/Time Activity (pCi/L)

Totalizer 1 Totalizer 2 Discharge Flow (gpm)

Water Discharge Volume (gal)

Activity discharged (pCi)

Activity discharged (Ci) 100s Cumulative Activity discharged (Ci) 101s Cumulative Activity discharged (Ci)

Total Cumulative Activity discharged (Ci) 04/21/15 09:30 2.35E-05 2.35E+04 1142550 1142550 1.47 2110 1.877E+08 1.88E-04 3.70E-01 8.07E-02 4.51E-01 04/22/15 08:30 2.35E-05 2.35E+04 1144660 1144660 1.51 2200 1.957E+08 1.96E-04 3.71E-01 8.09E-02 4.51E-01 04/23/15 09:00 2.35E-05 2.35E+04 1146860 1146860 1.45 2160 1.921E+08 1.92E-04 3.71E-01 8.11E-02 4.52E-01 04/24/15 08:40 2.35E-05 2.35E+04 1149020 1149020 1.50 2600 2.313E+08 2.31E-04 3.71E-01 8.13E-02 4.52E-01 04/25/15 13:02 2.35E-05 2.35E+04 1151620 1151620 1.49 2170 1.930E+08 1.93E-04 3.71E-01 8.16E-02 4.53E-01 04/26/15 13:05 2.35E-05 2.35E+04 1153790 1153790 1.53 1680 1.494E+08 1.49E-04 3.71E-01 8.18E-02 4.53E-01 04/27/15 07:40 2.35E-05 2.35E+04 1155470 1155470 1.47 2260 2.010E+08 2.01E-04 3.72E-01 8.21E-02 4.54E-01 04/28/15 08:45 2.29E-05 2.29E+04 1157730 1157730 1.46 2080 1.803E+08 1.80E-04 3.72E-01 8.24E-02 4.54E-01 04/29/15 07:50 2.29E-05 2.29E+04 1159810 1159810 1.46 2390 2.072E+08 2.07E-04 3.72E-01 8.27E-02 4.55E-01 04/30/15 10:30 2.29E-05 2.29E+04 1162200 1162200 1.47 1720 1.491E+08 1.49E-04 3.72E-01 8.29E-02 4.55E-01 05/01/15 06:00 2.29E-05 2.29E+04 1163920 1163920 1.43 2890 2.505E+08 2.51E-04 3.72E-01 8.33E-02 4.56E-01 05/02/15 14:15 2.29E-05 2.29E+04 1166810 1166810 1.57 2160 1.872E+08 1.87E-04 3.72E-01 8.36E-02 4.56E-01 05/03/15 14:16 2.29E-05 2.29E+04 1168970 1168970 1.50 2110 1.829E+08 1.83E-04 3.73E-01 8.39E-02 4.57E-01 05/04/15 13:50 2.29E-05 2.29E+04 1171080 1171080 1.51 1730 1.500E+08 1.50E-04 3.73E-01 8.41E-02 4.57E-01 05/05/15 09:05 1.75E-05 1.75E+04 1172810 1172810 1.45 1830 1.212E+08 1.21E-04 3.73E-01 8.45E-02 4.57E-01 05/06/15 12:45 1.75E-05 1.75E+04 1174640 1174640 1.15 1600 1.060E+08 1.06E-04 3.73E-01 8.49E-02 4.58E-01 05/07/15 12:00 1.75E-05 1.75E+04 1176240 1176240 1.16 1380 9.142E+07 9.14E-05 3.73E-01 8.52E-02 4.58E-01 05/08/15 08:00 1.75E-05 1.75E+04 1177620 1177620 1.14 2150 1.424E+08 1.42E-04 3.73E-01 8.57E-02 4.59E-01 05/09/15 00:07 1.75E-05 1.75E+04 1179770 1179770 1.16 1620 1.073E+08 1.07E-04 3.73E-01 8.61E-02 4.60E-01 05/10/15 15:10 1.75E-05 1.75E+04 1181390 1181390 1.15 1480 9.804E+07 9.80E-05 3.73E-01 8.65E-02 4.60E-01 05/11/15 12:45 1.75E-05 1.75E+04 1182870 1182870 1.14 1450 9.605E+07 9.61E-05 3.74E-01 8.69E-02 4.60E-01 05/12/15 10:16 1.23E-05 1.23E+04 1184320 1184320 1.12 1620 7.543E+07 7.54E-05 3.74E-01 8.73E-02 4.61E-01 05/13/15 10:10 1.23E-05 1.23E+04 1185940 1185940 1.13 1520 7.077E+07 7.08E-05 3.74E-01 8.77E-02 4.61E-01 05/14/15 08:05 1.23E-05 1.23E+04 1187460 1187460 1.14 2080 9.685E+07 9.68E-05 3.74E-01 8.83E-02 4.62E-01 05/15/15 12:45 1.23E-05 1.23E+04 1189540 1189540 1.86 3230 1.504E+08 1.50E-04 3.74E-01 8.88E-02 4.63E-01 05/16/15 17:36 1.23E-05 1.23E+04 1192770 1192770 1.89 2310 1.076E+08 1.08E-04 3.74E-01 8.92E-02 4.63E-01 05/17/15 14:25 1.23E-05 1.23E+04 1195080 1195080 1.88 2080 9.685E+07 9.68E-05 3.74E-01 8.95E-02 4.64E-01 05/18/15 09:00 1.23E-05 1.23E+04 1197160 1197160 1.68 2320 1.080E+08 1.08E-04 3.74E-01 8.99E-02 4.64E-01 05/19/15 07:50 1.31E-05 1.31E+04 1199480 1199480 1.67 0

0.000E+00 0.00E+00 3.74E-01 9.03E-02 4.65E-01 05/20/15 09:50 1.31E-05 1.31E+04 1199480 1199480 0.00 2150 1.066E+08 1.07E-04 3.74E-01 9.07E-02 4.65E-01 05/21/15 10:25 1.31E-05 1.31E+04 1201630 1201630 1.46 1910 9.471E+07 9.47E-05 3.74E-01 9.10E-02 4.65E-01 05/22/15 08:20 1.31E-05 1.31E+04 1203540 1203540 1.42 2520 1.250E+08 1.25E-04 3.75E-01 9.14E-02 4.66E-01 05/23/15 14:44 1.31E-05 1.31E+04 1206060 1206060 1.33 1960 9.719E+07 9.72E-05 3.75E-01 9.18E-02 4.67E-01 05/24/15 16:23 1.31E-05 1.31E+04 1208020 1208020 1.23 1360 6.744E+07 6.74E-05 3.75E-01 9.21E-02 4.67E-01 05/25/15 11:30 1.31E-05 1.31E+04 1209380 1209380 1.15 2460 1.220E+08 1.22E-04 3.75E-01 9.25E-02 4.67E-01

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 25 of 31 RW-LS-100s Sample Results Exelon ENV LLD Date/Time Activity (pCi/L)

Totalizer 1 Totalizer 2 Discharge Flow (gpm)

Water Discharge Volume (gal)

Activity discharged (pCi)

Activity discharged (Ci) 100s Cumulative Activity discharged (Ci) 101s Cumulative Activity discharged (Ci)

Total Cumulative Activity discharged (Ci) 05/26/15 11:08 1.25E-05 1.25E+04 1211840 1211840 1.83 3230 1.528E+08 1.53E-04 3.75E-01 9.29E-02 4.68E-01 05/27/15 11:30 1.25E-05 1.25E+04 1215070 1215070 2.18 3030 1.434E+08 1.43E-04 3.75E-01 9.30E-02 4.68E-01 05/28/15 10:50 1.25E-05 1.25E+04 1218100 1218100 2.13 3050 1.443E+08 1.44E-04 3.75E-01 9.33E-02 4.69E-01 05/29/15 11:35 1.25E-05 1.25E+04 1221150 1221150 2.06 3630 1.718E+08 1.72E-04 3.76E-01 9.36E-02 4.69E-01 05/30/15 17:40 1.25E-05 1.25E+04 1224780 1224780 1.89 2350 1.112E+08 1.11E-04 3.76E-01 9.40E-02 4.70E-01 05/31/15 14:13 1.25E-05 1.25E+04 1227130 1227130 1.88 2260 1.069E+08 1.07E-04 3.76E-01 9.42E-02 4.70E-01 06/01/15 10:10 1.25E-05 1.25E+04 1229390 1229390 1.85 2470 1.169E+08 1.17E-04 3.76E-01 9.44E-02 4.70E-01 06/02/15 08:20 1.23E-05 1.23E+04 1231860 1231860 1.85 2710 1.262E+08 1.26E-04 3.76E-01 9.46E-02 4.71E-01 06/03/15 10:10 1.23E-05 1.23E+04 1234570 1234570 1.73 2510 1.169E+08 1.17E-04 3.76E-01 9.49E-02 4.71E-01 06/04/15 10:25 1.23E-05 1.23E+04 1237080 1237080 1.69 2130 9.917E+07 9.92E-05 3.76E-01 9.51E-02 4.71E-01 06/05/15 07:30 1.23E-05 1.23E+04 1239210 1239210 1.65 3200 1.490E+08 1.49E-04 3.76E-01 9.55E-02 4.72E-01 06/06/15 14:40 1.23E-05 1.23E+04 1242410 1242410 1.70 2480 1.155E+08 1.15E-04 3.76E-01 9.58E-02 4.72E-01 06/07/15 15:35 1.23E-05 1.23E+04 1244890 1244890 1.65 1710 7.962E+07 7.96E-05 3.77E-01 9.60E-02 4.73E-01 06/08/15 09:00 1.23E-05 1.23E+04 1246600 1246600 1.62 2170 1.010E+08 1.01E-04 3.77E-01 9.63E-02 4.73E-01 06/09/15 07:25 1.12E-05 1.12E+04 1248770 1248770 1.57 2300 9.751E+07 9.75E-05 3.77E-01 9.65E-02 4.73E-01 06/10/15 07:55 1.12E-05 1.12E+04 1251070 1251070 1.49 2240 9.497E+07 9.50E-05 3.77E-01 9.68E-02 4.74E-01 06/11/15 08:50 1.12E-05 1.12E+04 1253310 1253310 1.44 2190 9.285E+07 9.28E-05 3.77E-01 9.71E-02 4.74E-01 06/12/15 10:30 1.12E-05 1.12E+04 1255500 1255500 1.41 2390 1.013E+08 1.01E-04 3.77E-01 9.74E-02 4.74E-01 06/13/15 15:00 1.12E-05 1.12E+04 1257890 1257890 1.39 1930 8.183E+07 8.18E-05 3.77E-01 9.76E-02 4.75E-01 06/14/15 14:10 1.12E-05 1.12E+04 1259820 1259820 1.47 1760 7.462E+07 7.46E-05 3.77E-01 9.78E-02 4.75E-01 06/15/15 10:30 1.12E-05 1.12E+04 1261580 1261580 1.39 1710 7.250E+07 7.25E-05 3.77E-01 9.80E-02 4.75E-01 06/16/15 07:10 1.14E-05 1.14E+04 1263290 1263290 1.34 2000 8.631E+07 8.63E-05 3.77E-01 9.82E-02 4.76E-01

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 26 of 31 RW-LS-101s Sample Results Exelon ENV LLD Date/Time Activity (pCi/L)

Totalizer 1 Totalizer 2 Discharge Flow (gpm)

Water Discharge Volume (gal)

Activity discharged (pCi)

Activity discharged (Ci)

Cumulative Activity discharged (Ci) 01/01/15 15:40 1.63E-05 1.63E+04 27699 27699 1.00 1025 6.324E+07 6.32E-05 6.49E-02 01/02/15 08:55 1.80E-05 1.80E+04 28724 28724 0.95 1542 1.051E+08 1.05E-04 6.50E-02 01/03/15 14:06 1.79E-05 1.79E+04 30266 30266 0.80 1159 7.854E+07 7.85E-05 6.51E-02 01/04/15 14:25 1.74E-05 1.74E+04 31426 31426 0.80 975 6.419E+07 6.42E-05 6.52E-02 01/05/15 10:55 0.00E+00 32400 32400 0.80 1187 0.000E+00 0.00E+00 6.52E-02 01/06/15 07:15 1.72E-05 1.72E+04 33587 33587 0.98 1362 8.866E+07 8.87E-05 6.53E-02 01/07/15 08:25 1.84E-05 1.84E+04 34948 34948 0.88 1401 9.759E+07 9.76E-05 6.54E-02 01/08/15 11:00 0.00E+00 36349 36349 0.86 1060 0.000E+00 0.00E+00 6.54E-02 01/09/15 07:55 0.00E+00 37410 37410 0.83 1622 0.000E+00 0.00E+00 6.54E-02 01/10/15 15:15 1.70E-05 1.70E+04 39032 39032 0.90 1215 7.819E+07 7.82E-05 6.55E-02 01/11/15 14:30 1.53E-05 1.53E+04 40247 40247 0.85 1021 5.913E+07 5.91E-05 6.55E-02 01/12/15 10:10 1.76E-05 1.76E+04 41268 41268 0.83 1163 7.751E+07 7.75E-05 6.56E-02 01/13/15 08:00 1.76E-05 1.76E+04 42431 42431 0.86 1273 8.478E+07 8.48E-05 6.57E-02 01/14/15 08:50 1.53E-05 1.53E+04 43704 43704 0.92 321 1.858E+07 1.86E-05 6.57E-02 01/15/15 05:00 1.53E-05 1.53E+04 44025 44025 0.90 3340 1.935E+08 1.93E-04 6.59E-02 01/16/15 07:30 1.71E-05 1.71E+04 47365 47365 1.64 3118 2.018E+08 2.02E-04 6.61E-02 01/17/15 14:41 1.61E-05 1.61E+04 50483 50483 1.72 2273 1.385E+08 1.39E-04 6.62E-02 01/18/15 14:51 1.63E-05 1.63E+04 52756 52756 1.49 2146 1.324E+08 1.32E-04 6.64E-02 01/19/15 15:32 1.69E-05 1.69E+04 54902 54902 1.53 1567 1.003E+08 1.00E-04 6.65E-02 01/20/15 08:44 1.69E-05 1.69E+04 56469 56469 1.46 1999 1.279E+08 1.28E-04 6.66E-02 01/21/15 07:45 1.87E-05 1.87E+04 58468 58468 1.42 2014 1.425E+08 1.43E-04 6.67E-02 01/22/15 07:10 1.77E-05 1.77E+04 60482 60482 1.44 2180 1.461E+08 1.46E-04 6.69E-02 01/23/15 08:25 1.70E-05 1.70E+04 62662 62662 96.00 2952 1.900E+08 1.90E-04 6.71E-02 01/24/15 14:32 1.65E-05 1.65E+04 65614 65614 1.78 2379 1.486E+08 1.49E-04 6.72E-02 01/25/15 14:35 1.85E-05 1.85E+04 67993 67993 1.57 1605 1.124E+08 1.12E-04 6.73E-02 01/26/15 08:22 1.83E-05 1.83E+04 69598 69598 1.58 2156 1.494E+08 1.49E-04 6.75E-02 01/27/15 07:21 1.73E-05 1.73E+04 71755 71755 1.45 2122 1.389E+08 1.39E-04 6.76E-02 01/28/15 07:58 1.63E-05 1.63E+04 73876 73876 1.49 2386 1.472E+08 1.47E-04 6.78E-02 01/29/15 08:12 1.63E-05 1.63E+04 76263 76263 1.63 1992 1.229E+08 1.23E-04 6.79E-02 01/30/15 07:00 1.63E-05 1.63E+04 78255 78255 1.40 2470 1.524E+08 1.52E-04 6.80E-02 01/31/15 11:17 1.63E-05 1.63E+04 80725 80725 1.55 2062 1.273E+08 1.27E-04 6.82E-02

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 27 of 31 RW-LS-101s Sample Results Exelon ENV LLD Date/Time Activity (pCi/L)

Totalizer 1 Totalizer 2 Discharge Flow (gpm)

Water Discharge Volume (gal)

Activity discharged (pCi)

Activity discharged (Ci)

Cumulative Activity discharged (Ci) 02/01/15 08:30 1.63E-05 1.63E+04 82787 82787 1.70 5226 3.225E+08 3.22E-04 6.85E-02 02/03/15 10:20 1.81E-05 1.81E+04 88013 88013 1.87 2836 1.943E+08 1.94E-04 6.87E-02 02/04/15 10:43 1.81E-05 1.81E+04 90849 90849 1.85 2711 1.857E+08 1.86E-04 6.89E-02 02/05/15 11:28 1.81E-05 1.81E+04 93560 93560 1.80 6031 4.132E+08 4.13E-04 6.93E-02 02/07/15 13:42 1.81E-05 1.81E+04 99591 99591 2.12 2684 1.839E+08 1.84E-04 6.95E-02 02/08/15 10:25 1.81E-05 1.81E+04 102274 102274 2.16 2687 1.841E+08 1.84E-04 6.96E-02 02/09/15 07:00 1.81E-05 1.81E+04 104961 104961 2.16 3185 2.182E+08 2.18E-04 6.99E-02 02/10/15 07:00 1.91E-05 1.91E+04 108146 108146 2.30 3585 2.592E+08 2.59E-04 7.01E-02 02/11/15 07:48 1.91E-05 1.91E+04 111731 111731 2.43 4072 2.944E+08 2.94E-04 7.04E-02 02/12/15 13:21 1.91E-05 1.91E+04 115803 115803 2.12 2859 2.067E+08 2.07E-04 7.06E-02 02/13/15 10:57 1.91E-05 1.91E+04 118662 118662 2.32 2987 2.160E+08 2.16E-04 7.08E-02 02/14/15 07:51 1.91E-05 1.91E+04 121649 121649 2.35 3009 2.176E+08 2.18E-04 7.11E-02 02/15/15 08:00 1.91E-05 1.91E+04 124658 124658 2.01 2962 2.142E+08 2.14E-04 7.13E-02 02/16/15 07:30 1.91E-05 1.91E+04 127620 127620 2.21 3202 2.315E+08 2.32E-04 7.15E-02 02/17/15 07:14 1.80E-05 1.80E+04 130822 130822 2.24 3335 2.272E+08 2.27E-04 7.17E-02 02/18/15 08:10 1.80E-05 1.80E+04 134157 134157 2.15 2781 1.895E+08 1.89E-04 7.19E-02 02/19/15 07:10 1.80E-05 1.80E+04 136938 136938 1.92 3324 2.265E+08 2.26E-04 7.21E-02 02/20/15 11:05 1.80E-05 1.80E+04 140262 140262 2.09 2978 2.029E+08 2.03E-04 7.24E-02 02/21/15 11:25 1.80E-05 1.80E+04 143240 143240 1.91 2403 1.637E+08 1.64E-04 7.25E-02 02/22/15 10:06 1.80E-05 1.80E+04 145643 145643 1.61 2158 1.470E+08 1.47E-04 7.27E-02 02/23/15 09:00 1.80E-05 1.80E+04 147801 147801 1.57 2440 1.663E+08 1.66E-04 7.28E-02 02/24/15 08:00 1.50E-05 1.50E+04 150241 150241 1.96 3095 1.757E+08 1.76E-04 7.30E-02 02/25/15 11:07 1.50E-05 1.50E+04 153336 153336 1.78 2044 1.161E+08 1.16E-04 7.31E-02 02/26/15 07:00 1.50E-05 1.50E+04 155380 155380 1.22 2540 1.442E+08 1.44E-04 7.33E-02 02/27/15 11:12 1.50E-05 1.50E+04 157920 157920 1.64 1982 1.125E+08 1.13E-04 7.34E-02 02/28/15 10:40 1.50E-05 1.50E+04 159902 159902 1.57 2025 1.150E+08 1.15E-04 7.35E-02 03/01/15 08:43 1.50E-05 1.50E+04 161927 161927 1.50 2495 1.417E+08 1.42E-04 7.36E-02 03/02/15 12:40 1.50E-05 1.50E+04 164422 164422 1.77 2241 1.272E+08 1.27E-04 7.38E-02 03/03/15 08:40 1.42E-05 1.42E+04 166663 166663 2241 1.204E+08 1.20E-04 7.39E-02 03/04/15 10:10 1.42E-05 1.42E+04 168903 168903 1.65 2672 1.436E+08 1.44E-04 7.40E-02 03/05/15 19:31 1.42E-05 1.42E+04 171575 171575 1.39 1213 6.520E+07 6.52E-05 7.41E-02

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 28 of 31 RW-LS-101s Sample Results Exelon ENV LLD Date/Time Activity (pCi/L)

Totalizer 1 Totalizer 2 Discharge Flow (gpm)

Water Discharge Volume (gal)

Activity discharged (pCi)

Activity discharged (Ci)

Cumulative Activity discharged (Ci) 03/06/15 10:45 1.42E-05 1.42E+04 172788 172788 1.35 2584 1.389E+08 1.39E-04 7.42E-02 03/07/15 15:13 1.42E-05 1.42E+04 175372 175372 1.39 1867 1.004E+08 1.00E-04 7.43E-02 03/08/15 14:45 1.42E-05 1.42E+04 177239 177239 1.63 1251 6.724E+07 6.72E-05 7.44E-02 03/09/15 07:30 1.42E-05 1.42E+04 178490 178490 1.30 1735 9.326E+07 9.33E-05 7.45E-02 03/10/15 07:00 1.48E-05 1.48E+04 180225 180225 1.03 1661 9.306E+07 9.31E-05 7.46E-02 03/11/15 07:35 1.48E-05 1.48E+04 181886 181886 1.20 1429 8.006E+07 8.01E-05 7.47E-02 03/12/15 07:00 1.48E-05 1.48E+04 183315 183315 1.20 1761 9.866E+07 9.87E-05 7.48E-02 03/13/15 10:40 1.48E-05 1.48E+04 185076 185076 0.94 1877 1.052E+08 1.05E-04 7.49E-02 03/14/15 13:15 1.48E-05 1.48E+04 186953 186953 1.17 1424 7.978E+07 7.98E-05 7.49E-02 03/15/15 10:25 1.48E-05 1.48E+04 188377 188377 1.35 1538 8.617E+07 8.62E-05 7.50E-02 03/16/15 08:05 1.48E-05 1.48E+04 189915 189915 1.20 1675 9.384E+07 9.38E-05 7.51E-02 03/17/15 07:10 1.61E-05 1.61E+04 191590 191590 0.93 1845 1.124E+08 1.12E-04 7.52E-02 03/18/15 12:35 1.61E-05 1.61E+04 193435 193435 0.96 1669 1.017E+08 1.02E-04 7.53E-02 03/19/15 13:25 1.61E-05 1.61E+04 195104 195104 1.18 1332 8.118E+07 8.12E-05 7.54E-02 03/20/15 08:10 1.61E-05 1.61E+04 196436 196436 1.17 4191 2.554E+08 2.55E-04 7.57E-02 03/22/15 15:55 1.61E-05 1.61E+04 200627 200627 1.35 1318 8.033E+07 8.03E-05 7.58E-02 03/23/15 09:00 1.61E-05 1.61E+04 201945 201945 1.27 1850 1.127E+08 1.13E-04 7.59E-02 03/24/15 09:00 1.70E-05 1.70E+04 203795 203795 1.34 1994 1.283E+08 1.28E-04 7.60E-02 03/25/15 08:15 1.70E-05 1.70E+04 205789 205789 1.33 2080 1.339E+08 1.34E-04 7.61E-02 03/26/15 09:00 1.70E-05 1.70E+04 207869 207869 1.41 1930 1.242E+08 1.24E-04 7.63E-02 03/27/15 07:30 1.70E-05 1.70E+04 209799 209799 1.35 2611 1.680E+08 1.68E-04 7.64E-02 03/28/15 15:15 1.70E-05 1.70E+04 212410 212410 1.42 2112 1.359E+08 1.36E-04 7.66E-02 03/29/15 15:35 1.70E-05 1.70E+04 214522 214522 1.56 1550 9.975E+07 9.97E-05 7.67E-02 03/30/15 08:53 1.70E-05 1.70E+04 216072 216072 1.43 2051 1.320E+08 1.32E-04 7.68E-02 03/31/15 07:20 1.82E-05 1.82E+04 218123 218123 1.50 2278 1.569E+08 1.57E-04 7.69E-02 04/01/15 09:15 1.82E-05 1.82E+04 220401 220401 1.47 2148 1.480E+08 1.48E-04 7.71E-02 04/02/15 08:35 1.82E-05 1.82E+04 222549 222549 1.61 2339 1.611E+08 1.61E-04 7.73E-02 04/03/15 09:05 1.82E-05 1.82E+04 224888 224888 1.56 2820 1.943E+08 1.94E-04 7.75E-02 04/04/15 15:00 1.82E-05 1.82E+04 227708 227708 1.63 2370 1.633E+08 1.63E-04 7.76E-02 04/05/15 14:50 1.82E-05 1.82E+04 230078 230078 1.69 1771 1.220E+08 1.22E-04 7.77E-02 04/06/15 08:19 1.82E-05 1.82E+04 231849 231849 1.69 2400 1.653E+08 1.65E-04 7.79E-02

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 29 of 31 RW-LS-101s Sample Results Exelon ENV LLD Date/Time Activity (pCi/L)

Totalizer 1 Totalizer 2 Discharge Flow (gpm)

Water Discharge Volume (gal)

Activity discharged (pCi)

Activity discharged (Ci)

Cumulative Activity discharged (Ci) 04/07/15 08:20 2.07E-05 2.07E+04 234249 234249 1.59 2245 1.759E+08 1.76E-04 7.81E-02 04/08/15 07:15 2.07E-05 2.07E+04 236494 236494 1.62 2812 2.203E+08 2.20E-04 7.83E-02 04/09/15 11:18 2.07E-05 2.07E+04 239306 239306 1.62 2165 1.696E+08 1.70E-04 7.85E-02 04/10/15 08:25 2.07E-05 2.07E+04 241471 241471 1.58 2623 2.055E+08 2.06E-04 7.87E-02 04/11/15 14:25 2.07E-05 2.07E+04 244094 244094 1.43 2296 1.799E+08 1.80E-04 7.89E-02 04/12/15 14:45 2.07E-05 2.07E+04 246390 246390 1.73 1963 1.538E+08 1.54E-04 7.90E-02 04/13/15 10:10 2.07E-05 2.07E+04 248353 248353 1.52 2067 1.620E+08 1.62E-04 7.92E-02 04/14/15 08:30 2.03E-05 2.03E+04 250420 250420 1.50 2275 1.748E+08 1.75E-04 7.93E-02 04/15/15 09:10 2.03E-05 2.03E+04 252695 252695 1.59 2149 1.651E+08 1.65E-04 7.95E-02 04/16/15 07:19 2.03E-05 2.03E+04 254844 254844 1.63 2412 1.853E+08 1.85E-04 7.97E-02 04/17/15 08:03 2.03E-05 2.03E+04 257256 257256 1.62 3363 2.584E+08 2.58E-04 8.00E-02 04/18/15 18:40 2.03E-05 2.03E+04 260619 260619 1.54 2070 1.591E+08 1.59E-04 8.01E-02 04/19/15 14:30 2.03E-05 2.03E+04 262689 262689 1.85 2024 1.555E+08 1.56E-04 8.03E-02 04/20/15 08:00 2.03E-05 2.03E+04 264713 264713 1.85 2647 2.034E+08 2.03E-04 8.05E-02 04/21/15 09:30 2.27E-05 2.27E+04 267360 267360 4.21 2397 2.060E+08 2.06E-04 8.07E-02 04/22/15 08:30 2.27E-05 2.27E+04 269757 269757 1.55 2416 2.076E+08 2.08E-04 8.09E-02 04/23/15 09:00 2.27E-05 2.27E+04 272173 272173 1.53 2307 1.982E+08 1.98E-04 8.11E-02 04/24/15 08:40 2.27E-05 2.27E+04 274480 274480 1.66 3079 2.646E+08 2.65E-04 8.13E-02 04/25/15 13:00 2.27E-05 2.27E+04 277559 277559 2.02 2890 2.483E+08 2.48E-04 8.16E-02 04/26/15 13:06 2.27E-05 2.27E+04 280449 280449 1.68 2370 2.037E+08 2.04E-04 8.18E-02 04/27/15 07:40 2.27E-05 2.27E+04 282819 282819 2.15 3282 2.820E+08 2.82E-04 8.21E-02 04/28/15 08:45 2.40E-05 2.40E+04 286101 286101 2.19 3158 2.869E+08 2.87E-04 8.24E-02 04/29/15 07:50 2.40E-05 2.40E+04 289259 289259 2.29 3726 3.385E+08 3.39E-04 8.27E-02 04/30/15 10:30 2.40E-05 2.40E+04 292985 292985 2.31 2529 2.298E+08 2.30E-04 8.29E-02 05/01/15 06:00 2.40E-05 2.40E+04 295514 295514 2.14 4176 3.794E+08 3.79E-04 8.33E-02 05/02/15 14:14 2.40E-05 2.40E+04 299690 299690 2.18 3178 2.887E+08 2.89E-04 8.36E-02 05/03/15 14:15 2.40E-05 2.40E+04 302868 302868 2.21 3025 2.748E+08 2.75E-04 8.39E-02 05/04/15 13:51 2.40E-05 2.40E+04 305893 305893 1.96 2322 2.110E+08 2.11E-04 8.41E-02 05/05/15 09:05 2.52E-05 2.52E+04 308215 308215 2.07 4099 3.910E+08 3.91E-04 8.45E-02 05/06/15 12:45 2.52E-05 2.52E+04 312314 312314 2.62 3888 3.709E+08 3.71E-04 8.49E-02 05/07/15 12:00 2.52E-05 2.52E+04 316202 316212 2.84 3512 3.350E+08 3.35E-04 8.52E-02

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 30 of 31 RW-LS-101s Sample Results Exelon ENV LLD Date/Time Activity (pCi/L)

Totalizer 1 Totalizer 2 Discharge Flow (gpm)

Water Discharge Volume (gal)

Activity discharged (pCi)

Activity discharged (Ci)

Cumulative Activity discharged (Ci) 05/08/15 08:00 2.52E-05 2.52E+04 319714 319714 2.90 5564 5.308E+08 5.31E-04 8.57E-02 05/09/15 15:17 2.52E-05 2.52E+04 325278 325278 3.00 4372 4.171E+08 4.17E-04 8.61E-02 05/10/15 15:10 2.52E-05 2.52E+04 329650 329650 3.08 4057 3.870E+08 3.87E-04 8.65E-02 05/11/15 12:45 2.52E-05 2.52E+04 333707 333707 3.18 3983 3.799E+08 3.80E-04 8.69E-02 05/12/15 10:15 2.64E-05 2.64E+04 337690 337690 2.95 4140 4.137E+08 4.14E-04 8.73E-02 05/13/15 10:10 2.64E-05 2.64E+04 341830 341830 2.79 3936 3.933E+08 3.93E-04 8.77E-02 05/14/15 08:05 2.64E-05 2.64E+04 345766 345766 3.00 5546 5.542E+08 5.54E-04 8.83E-02 05/15/15 12:45 2.64E-05 2.64E+04 351312 351312 3.14 5395 5.391E+08 5.39E-04 8.88E-02 05/16/15 17:36 2.64E-05 2.64E+04 356707 356707 3.24 3850 3.847E+08 3.85E-04 8.92E-02 05/17/15 14:25 2.64E-05 2.64E+04 360557 360557 3.24 3307 3.305E+08 3.30E-04 8.95E-02 05/18/15 09:00 2.64E-05 2.64E+04 363864 363864 3.06 3700 3.698E+08 3.70E-04 8.99E-02 05/19/15 07:50 2.47E-05 2.47E+04 367564 367564 2.57 4154 3.884E+08 3.88E-04 9.03E-02 05/20/15 09:50 2.47E-05 2.47E+04 371718 371718 2.66 4077 3.812E+08 3.81E-04 9.07E-02 05/21/15 10:25 2.47E-05 2.47E+04 375795 375795 2.97 3637 3.401E+08 3.40E-04 9.10E-02 05/22/15 08:20 2.47E-05 2.47E+04 379432 379432 2.52 4658 4.355E+08 4.36E-04 9.14E-02 05/23/15 14:45 2.47E-05 2.47E+04 384090 384090 2.53 4157 3.887E+08 3.89E-04 9.18E-02 05/24/15 16:23 2.47E-05 2.47E+04 388247 388247 2.96 3288 3.074E+08 3.07E-04 9.21E-02 05/25/15 11:30 2.47E-05 2.47E+04 391535 391535 2.73 3843 3.593E+08 3.59E-04 9.25E-02 05/26/15 11:08 2.56E-05 2.56E+04 395378 395378 2.68 4223 4.092E+08 4.09E-04 9.29E-02 05/27/15 11:30 2.56E-05 2.56E+04 399601 399601 3.00 1553 1.505E+08 1.50E-04 9.30E-02 05/28/15 10:50 2.56E-05 2.56E+04 401154 401154 2.00 2800 2.713E+08 2.71E-04 9.33E-02 05/29/15 11:36 2.56E-05 2.56E+04 401154 401154 2.00 2972 2.880E+08 2.88E-04 9.36E-02 05/30/15 17:40 2.56E-05 2.56E+04 401154 401154 2.00 3608 3.496E+08 3.50E-04 9.40E-02 05/31/15 14:12 2.56E-05 2.56E+04 401154 401154 2.00 2464 2.388E+08 2.39E-04 9.42E-02 06/01/15 10:10 2.56E-05 2.56E+04 401154 401154 2.47 1644 1.593E+08 1.59E-04 9.44E-02 06/02/15 08:20 2.49E-05 2.49E+04 402798 402798 2.00 2660 2.507E+08 2.51E-04 9.46E-02 06/03/15 10:10 2.49E-05 2.49E+04 402799 402799 2.00 3100 2.922E+08 2.92E-04 9.49E-02 06/04/15 10:25 2.49E-05 2.49E+04 405592 405592 2.04 2598 2.449E+08 2.45E-04 9.51E-02 06/05/15 07:30 2.49E-05 2.49E+04 408190 408190 2.03 3767 3.551E+08 3.55E-04 9.55E-02 06/06/15 14:40 2.49E-05 2.49E+04 411957 411957 2.07 3151 2.970E+08 2.97E-04 9.58E-02 06/07/15 15:35 2.49E-05 2.49E+04 415108 415108 2.12 2159 2.035E+08 2.04E-04 9.60E-02

2015 Unit 1 Cycled Condensate Storage Tank Tritium Remediation Monitoring 31 of 31 RW-LS-101s Sample Results Exelon ENV LLD Date/Time Activity (pCi/L)

Totalizer 1 Totalizer 2 Discharge Flow (gpm)

Water Discharge Volume (gal)

Activity discharged (pCi)

Activity discharged (Ci)

Cumulative Activity discharged (Ci) 06/08/15 09:00 2.49E-05 2.49E+04 417267 417267 2.01 2754 2.596E+08 2.60E-04 9.63E-02 06/09/15 07:25 2.26E-05 2.26E+04 420021 420021 2.12 3102 2.654E+08 2.65E-04 9.65E-02 06/10/15 07:55 2.26E-05 2.26E+04 423123 423123 2.10 3132 2.679E+08 2.68E-04 9.68E-02 06/11/15 08:50 2.26E-05 2.26E+04 426255 426255 2.09 3199 2.737E+08 2.74E-04 9.71E-02 06/12/15 10:30 2.26E-05 2.26E+04 429454 429454 2.05 3493 2.988E+08 2.99E-04 9.74E-02 06/13/15 15:00 2.26E-05 2.26E+04 432947 432947 2.00 2789 2.386E+08 2.39E-04 9.76E-02 06/14/15 14:10 2.26E-05 2.26E+04 435736 435736 2.02 2491 2.131E+08 2.13E-04 9.78E-02 06/15/15 10:30 2.26E-05 2.26E+04 438227 438227 2.01 2495 2.134E+08 2.13E-04 9.80E-02 06/16/15 07:10 1.74E-05 1.74E+04 440722 440722 2.00 2996 1.973E+08 1.97E-04 9.82E-02