ML15195A370
| ML15195A370 | |
| Person / Time | |
|---|---|
| Site: | LaSalle |
| Issue date: | 07/02/2015 |
| From: | Exelon Generation Co |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML15195A351 | List:
|
| References | |
| RS-15-179 | |
| Download: ML15195A370 (143) | |
Text
1 LaSalle Environmental Audit Response to Request for Additional Information Index #:
014 RAI #:
AQ-04 Category: Aquatic Ecology Statement of Question:
Section 4.6 of the ER considers the effects of impingement and entrainment on aquatic biota in the Illinois River. In its analysis, the NRC staff will consider the effects of impingement and entrainment on aquatic biota in both the Illinois River and the cooling pond. To support this analysis, please describe any impingement and entrainment studies that have been conducted on the cooling pond or in the Illinois River.
- a. Docket the following reference:
EA Engineering. 2015. Draft Impingement and Entrainment Characterization Study La Salle County Station. May 2015.
- b. Provide a summary of the results and assessment of the impacts to fish in the Illinois River based on the information collected in EA Engineering (2015). Within this discussion, compare the impingement and entrainment rates at LSCS relative to other nearby energy facilities that withdraw river water.
c.
Docket the final report of EA Engineering (2015) when available.
Response
- a. The requested reference document is being provided as Attachment 1 to this response.
- b. The volume of water drawn through the river intake structure at LSCS, which has a closed cycle cooling system, and associated rates of impingement and entrainment are substantially less than for open cycle generating stations that withdraw their entire cooling volume from a lake or river. In order to provide additional perspective, LSCS impingement and entrainment rates were compared to two open cycle stations and one dual mode station within the Upper Illinois Waterway and Illinois River Basin. The three stations include two NRG/Midwest Generation facilities, Will County and Joliet 29 Stations, as well as Exelons Dresden Nuclear Station.
Station Intake and Discharge Waterbody River Mile Will County Chicago Sanitary and Ship Canal 295.4 Joliet 29 Des Plaines River 284.6 Dresden Kankakee and Illinois Rivers 272.3 LaSalle Illinois River 249.5 Table 1 summarizes impingement and entrainment results from each of the four stations.
The Joliet 29 and Dresden studies were each conducted over two years while the Will County study, like LSCS, was a one year study. Will County and Joliet 29 are open cycle cooling stations, whereas Dresden operates under one of two modes of cooling depending on the time of year. From 15 June to 30 September (3.5 months), Dresden operates in an indirect-open cycle mode, where water is drawn in through the circulating water intake structure on the Kankakee River, conveyed to the condensers, and cycled through the Dresden cooling pond before being discharged into the Illinois River. The
2 remainder of the year (8.5 months), Dresden operates its cooling pond in a closed cycle, similar to LSCS.
In terms of water use, makeup water for LSCS (86 to 88 mgd) represents six to 10 percent of the daily cooling water volume at the two open cycle stations (Table 1). This is also true for Dresden Nuclear Station during the limited time that it operates in indirect-open cycle each year. Similarly, LSCS 12-month impingement estimates ranged from one to 25 percent and entrainment estimates represented 14 to 43 percent of the total impingement and entrainment observed at the two upstream open cycle stations and Dresden during its 3.5 month indirect-open cycle operating time. In other words, entrainment at the closed cycle LSCS was 57 to 86 percent lower than entrainment during open cycle operation at the other Illinois plants in this comparison. Also, impingement at LSCS was 75 to 99 percent lower than impingement during open cycle operation at the three upstream facilities. Those differences are consistent with U.S.
EPAs projections that closed cycle cooling would reduce impingement and entrainment losses by up to 95 percent.
Table 1.
Comparison of impingement and entrainment estimates between LSCS and generating stations within the Illinois River watershed Station Year Mode of Cooling Typical CW Flow (mgd)1 Estimated Impingement Estimated Entrainment Will County Station 2004-2005 Open Cycle 864 41,884 278,025,810 Joliet 29 Station 2004-2005 Open Cycle 1,018 - 1,023 355, 844 122,123,878 2005-2006 860 - 1,007 487,786 183,196,758 Dresden Nuclear Station2 2005-2006 Indirect-Open Cycle 1,330 - 1,400 1,016,975 88,289,628 2006-2007 1,285 - 1,402 181,274 137,264,687 LaSalle County Nuclear Station 2014-2015 Closed Cycle 86 - 883 10,673 38,078,968 NOTES:
1 Depending on availability of data, "typical" circulating water (CW) flow among the various studies may represent mean or median flow in millions of gallons per day (mgd) over the course of the study.
2 Dresden Nuclear Station operates as indirect-open cycle during 15 June to 30 September and closed cycle the remainder of the year. Data provided are based on collections only during the 3.5 months of indirect-open cycle operation each year.
3 LSCS flows represent make-up water pumping rates.
SOURCES:
EA Engineering, Science, and Technology, Inc. (EA). 2007a. Impingement Mortality and Entrainment Characterization Study, Will County Station. Prepared for Midwest Generation EME, LLC, Chicago IL.
EA Engineering, Science, and Technology, Inc. (EA). 2007b. Impingement Mortality Characterization Study, Joliet Station 29 (Units 7 and 8). Prepared for Midwest Generation EME, LLC, Chicago IL.
3 EA Engineering, Science, and Technology, Inc. (EA). 2007c. Entrainment Characterization Study, Joliet Station 29 (Units 7 and 8). Prepared for Midwest Generation EME, LLC, Chicago IL.
EA Engineering, Science, and Technology, Inc. (EA). 2007d. Impingement Mortality Characterization Study, 2005 - 2007, Dresden Station. Prepared for Exelon Nuclear, Warrenville, IL.
EA Engineering, Science, and Technology, Inc. (EA). 2007e. Entrainment Characterization Study, 2005 - 2007, Dresden Station. Prepared for Exelon Nuclear, Warrenville, IL.
- c. Exelon Generation needs additional time to respond to this RAI. The requested final report by EA Engineering, Science, and Technology, Inc. concerning the impingement and entrainment characterization studies at the LSCS river intake is expected to be available in August 2015. The final report will be provided to the NRC staff as a supplement to this RAI response when it becomes available.
List of Attachments:
- 1. EA Engineering. 2015. Draft Impingement Mortality and Entrainment Characterization Study La Salle County Station. Prepared for Exelon Generation Company, LLC. May 2015.
RAI # AQ-04 ATTACHMENT 1
DRAFT Impingement Mortality and Entrainment Characterization Study LaSalle County Station Prepared for Exelon Generation Company, LLC 200 Exelon Way Kennett Square, Pennsylvania Prepared by EA Engineering, Science, and Technology, Inc., PBC 444 Lake Cook Road, Suite 18 Deerfield, IL 60015 May 2015 15004.03 DRAFT
TABLE OF CONTENTS Page EXECUTIVE
SUMMARY
- 1.
INTRODUCTION...............................................................................................................1 1.1 STUDY OBJECTIVES............................................................................................1 1.1 SITE DESCRIPTION..............................................................................................2
- 2.
METHODS..........................................................................................................................3 2.1 SAMPLING FREQUENCY AND DURATION.....................................................3 2.1.1 Impingement.................................................................................................3 2.1.2 Entrainment...................................................................................................3 2.2 SAMPLE COLLECTION AND PROCESSING.....................................................3 2.2.1 Impingement.................................................................................................3 2.2.2 Entrainment...................................................................................................4 2.3 IMPINGEMENT DATA MANAGEMENT AND ANALYSIS.............................5 2.3.1 Data Management.......................................................................................5 2.3.2 Cooling Water Volume and Temperature....................................................6 2.3.3 Impingement Estimates................................................................................6 2.4 ENTRAINMENT DATA MANAGEMENT AND ANALYSIS............................7 2.4.1 Data Management..........................................................................................7 2.5 QUALITY ASSURANCE AND QUALITY CONTROL.......................................8
- 3.
RESULTS AND DISCUSSION............................................................................................
- 4.
DISCUSSION........................................................................................................................
- 5.
REFERENCES......................................................................................................................
Appendix A: Raw impingement data listing for impingement at LaSalle County Station by sampling date, April 2014-March 2015...................................................................................... A-1 Appendix B: Number, biomass, and relative abundance of shellfish and fish collected during impingement at LaSalle County Station by sampling date, April 2014-March 2015......B-1 i
DRAFT
Appendix C: CPE by number (No. per volume) and weight (Kg. per volume) for shellfish and fish collected during impingement at LaSalle County Station by sampling date, April 2014-March 2015..........................C-1 Appendix D: Raw Ichthyoplankton Entrainment Data Collected at LaSalle County Station, April 2014-August 2014..... D-1 ii DRAFT
LIST OF FIGURES Number 1 LaSalle County Station Intake and Discharge Area 2 Estimated Entrainment of Ichthyoplankton for Each Extrapolation Period at LaSalle County Station, 30 March -30 August 2014.
3 Estimated Entrainment of Dominant Ichthyoplankton Taxa for Each Extrapolation Period at LaSalle County Station, 30 March -30 August 2014 iii DRAFT
LIST OF TABLES Number 1
Summary of Water Use during Impingement Sampling and Extrapolation Periods, LaSalle County Station, April 2014 through March 2015.
2 Summary of Water Use during Entrainment Sampling and Extrapolation Periods, LaSalle County Station, April 2005 through August 2005.
3 Family, Common, and Scientific Names of Crayfish, Mussels, and Fishes Collected During Impingement Sampling at the LaSalle Station, April 2014 through March 2015.
4 Number and Biomass of Crayfish, Mussels, and Fish Collected During Impingement Sampling at the LaSalle, April 2014 through March 2015.
5 Impingement Estimates at LaSalle Station, April 2014 through March 2015.
6 Monthly Length Frequency Distribution for Gizzard Shad Impinged at LaSalle Station, April 2014 - March 2015.
7 Monthly Length Frequency Distribution for Threadfin Shad Impinged at LaSalle Station, April 2014 - March 2015.
8 Monthly Length Frequency Distribution for Bluegill Impinged at LaSalle Station, April 2014 - March 2015.
9 Monthly Length Frequency Distribution for Freshwater Drum Impinged at LaSalle Station, April 2014 - March 2015.
10 Monthly Length Frequency Distribution for Round Goby Impinged at LaSalle Station, April 2014 - March 2015.
11 Length Frequency Distribution for Five Abundant Species Impinged at LaSalle Station, April 2014 - March 2015.
12 Comparison of Length Data for Sportfish Impinged at LaSalle Station to Stock and Quality Length Categories.
13 Water Temperatures Recorded during Impingement Sampling Events, LaSalle Station, April 2014 through March 2015.
14 Number and Relative Abundance of Ichthyoplankton Taxa Collected during Entrainment Sampling at LaSalle County Station, 3 April - 26 August 2014.
15 Ichthyoplankton Taxa Entrainment Estimates for LaSalle County Station, 30 March-30 August 2014.
iv DRAFT
LIST OF TABLES (Continued)
Number 16 Diel Comparisons of the Number, Density, and Relative Abundance of Ichthyoplankton Collected during Entrainment Sampling at LaSalle County Station, 3 April - 26 August 2014.
17 Diel Comparisons of the Number, Density, and Relative Abundance of Ichthyoplankton Collected during Each Entrainment Sampling Event at LaSalle County Station, 3 April
- 26 August 2015.
18 Depth Comparisons of the Number, Density, and Relative Abundance of Ichthyoplankton Collected during Entrainment Sampling at LaSalle County Station, 3 April - 26 August 2014.
19 Depth Comparisons of the Number, Density, and Relative Abundance of Ichthyoplankton Collected during Each Entrainment Sampling Event at LaSalle County Station, 3 April - 26 August 2015.
20 Total Length (mm) Data for Fish Impinged at LaSalle Station, April 2014 through March 2015.
21 Fish Larvae Length and Fish Egg Diameter (millimeters) Statistics for Ichthyoplankton from Entrainment Samples Collected at LaSalle County Station, 3 April - 26 August 2014.
22 Water Temperatures Recorded during Entrainment Sampling Events, LaSalle County Station, April through August 2014.
23 Summary of Water Temperature, Dissolved Oxygen, and Current Velocity Measurements during Entrainment Sampling at LaSalle County Station, 3 April - 26 August 2014.
v DRAFT
- 1.
INTRODUCTION The impingement mortality and entrainment characterization study was conducted during 2014/
2015 for Exelons LaSalle County Nuclear Station (LSCS) to collect current aquatic biological information needed to support preparation of the Environmental Report as part of a U.S. Nuclear Regulatory Commission (NRC) license renewal application.
1.1 STUDY OBJECTIVES Exelon contracted EA Engineering, Science, and Technology, Inc., PBC (EA) to perform the LSCS Impingement Mortality and Entrainment Characterization Study (IMECS), which included a one-year impingement study that was conducted from April 2014 through March 2015 and a seasonal entrainment study conducted during the 2014 spawning season (April through August). The entrainment study was conducted during fish spawning and rearing periods typical for northern Illinois. Specific objectives of the study were to:
- Describe the fish and shellfish taxa composition in the impingement and entrainment samples collected from the LSCS makeup water intake structure under normal operations;
- Note the presence of any rare or listed species and the significance of such collections;
- As appropriate, note and discuss the presence of unusually large numbers of recreationally important species (e.g., black bass, temperate bass, channel catfish, etc.);
Provide size (length) distributions of the commonly impinged species;
- Characterize the entrainment of each taxon according to life stage
- Describe temporal patterns of the impingement and entrainment rates;
- Provide annual impingement estimates by number and weight for all species combined and for each species currently occurring at the LSCS makeup water intake structure under normal operations;
- Provide entrainment estimates for all taxa combined and by taxon and life stage currently occurring at the LSCS makeup water intake structure under normal operations;
- Describe the overall contribution of invasive species or taxa.
- Describe QA/QC procedures (including field audits) that were followed to ensure the accuracy of all data collected and calculations made; and
- Provide appendices that include all raw data collected, including plant operating and water temperature data.
1 DRAFT
1.2 SITE DESCRIPTION LSCS is located near the Illinois River in LaSalle County about 75 miles southwest of Chicago and 11 miles southeast of Ottawa, Illinois. LSCS is a two-unit, nuclear-powered, steam electric generating facility and both units began commercial operation in 1984. The annual mean net electrical power capacity rating for the Station is 2,327 megawatts electric (MWe).
Condenser cooling water and plant service water are provided by an approximately 833 hectare (ha) diked cooling pond adjacent to the plant. The River Screen House (RSH) on the Illinois River provides makeup water to the cooling pond (Figure 1). The discharge structure where blowdown from the cooling pond is returned enters the Illinois River approximately 275 meters downstream of the makeup water intake structure. The LSCS IMECS was conducted entirely in relation to makeup water operations at the RSH.
Makeup cooling water is withdrawn from the Illinois River at river mile 249.5, four miles north of LaSalle County Station and three miles upstream of the Marseilles Dam. Makeup water is withdrawn from the Illinois River at the RSH and conveyed approximately 3.5 miles to the cooling pond to replace losses due to evaporation, blowdown, and seepage using a combination of three makeup pumps. Makeup water requirements can be met by operating one or two pumps for normal operations with one pump for backup. Each pumps rated capacity is 30,000 gallons per minute (gpm). Maximum water withdrawal from the Illinois River is, therefore, approximately 90,000 gpm. Normal water withdrawal, with two pumps operating, is up to 60,000 gpm.
The makeup water intake system consists of an intake flume channeled into the bottom of the Illinois River and extending approximately 15 m out from the shoreline. Recessed seven meters from the shoreline is a 22 m wide funnel inlet. At the mouth of the inlet, a floating log boom diverts floating debris and, in the RSH forebay, a permanent floating oil boom prevents any oil spill from entering to the river. The inlet leads to two adjacent bar grills and traveling screens, with 3/8 inch screen openings, in the river screen house. When the cooling pond is at or near full pool, only one or two pumps are required to maintain the ponds water level. Velocities in the forebay range from 0.3 to 0.5 ft/second with one pump operating to 0.6 to 1.0 ft/second with two pumps operating, depending on river level. The velocity at the face of the travelling screens is 0.5 ft/second during one pump operation and 0.9 ft/second during occasional two pump operation. Debris removed from the traveling screens by a screen backwash system and from the bar grills by trash rakes is collected in a trash basket and disposed in an offsite permitted landfill. Consistent with State of Illinois regulations, trash basket contents are not returned to the Illinois River.
The following sections provide a description of the study methods (Section 2), the IMECS results (Section 3), which provide the basis for calculation of the estimate for LSCS (Section 4).
2 DRAFT
- 2.
METHODS The following sections provide details for the impingement and entrainment studies regarding sampling frequency and duration (Section 2.1), sample collection and processing procedures (Section 2.2), impingement (Section 2.3) and entrainment (Section 2.4) data management procedures, and quality assurance/quality control (QA/QC) measures (Section 2.5).
2.1 SAMPLING FREQUENCY AND DURATION 2.1.1 Impingement A total of 20 weekly impingement samples were collected between 2 April 2014 and 31 March 2015 from the makeup water intake (Table 1). Scheduled outages, maintenance outages, unworkable weather conditions resulted in the cancelling or postponement of multiple sampling events. When possible, missed sampling events were rescheduled. During each of the 20 weeks, a 24-hour sample was collected at the LSCS RSH. The 24-hour sampling duration goal was met for all 20 sampling events.
2.1.2 Entrainment Sampling was conducted at one location in forebay of the RSH every two weeks in April, once a week May through the week of 14 July, and once every two weeks through the end of the study in August. The sampling program represented 16 collection dates with duplicate samples collected from two depths (near surface and near bottom), twice (day/night) during each sampling event (duplicate samples x 2 depths x 2 sample times x 16 sampling dates) equals 128 samples (Table 2).
2.2 SAMPLE COLLECTION AND PROCESSING 2.2.1 Impingement The impingement study at LSCS focused on fish and shellfish, as this term has traditionally been interpreted by resource and regulatory agencies. Therefore, crayfish and native freshwater mussels were processed, but invasive taxa such as Corbicula (Asiatic clam) and Dreissena (zebra and quagga mussels) were excluded.
Exelon personnel were responsible for rotating the traveling screens and cleaning the collection basket (Figure 1) prior to initiating scheduled sampling events. During each 24-hour sampling period, facility personnel were responsible for monitoring the collection basket to prevent it from overflowing. If the traveling screens were in the continuous mode (always rotating), there was no need to manually operate the traveling screens either before or at the end of the sampling event.
However, when the traveling screens were being operated in other modes (e.g., manually, automatic, and/or on differential pressure), the traveling screens were manually operated at the start and end of each 24-hour collection period. The mesh size of the collection basket was the same size as the mesh size of the traveling screens (3/8-inch square mesh).
3 DRAFT
Impinged shellfish and fish were separated from the debris, identified, counted, weighed in grams (g) and total length (TL) was measured in millimeters (mm). Cyprinids (minnows), except for carp and goldfish, were measured and batch weighed. When 30 or fewer individuals of a single species were collected, all were individually measured and weighed, except as noted for minnows. When more than 30 individuals of a single species occurred in a sample and different size groups were obviously represented, fish were divided into small, medium, large size groups. Specimens were then randomly selected from each group in proportion to the contribution of that size group to the whole sample, so that at least 30 individuals were measured and weighed individually. The remainder of the individuals of species represented by more than 30 individuals were then counted and batch weighed by size group.
All fish and shellfish impinged during each sampling event were typically processed on site; however, specimens that could not be positively identified were returned to EAs Deerfield, Illinois laboratory for identification and processing. Deteriorated or damaged fish were identified to the lowest possible taxonomic level. Fish that were obviously dead longer than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> (e.g., those exhibiting advanced decomposition, missing scales and eyes, and excessive fungus relative to other fish in the sample) were not processed. A voucher collection of preserved specimens that were positively identified by an experienced taxonomist was compiled. The collection included unusual or taxonomically difficult species.
Operating conditions during each study were supplied by Exelon including intake water temperature, number, and duration of pumps operating, and makeup water (MW) volume pumped by hour for each sampling event, as well as daily, weekly, and monthly MW volume totals. MW volume data were used to extrapolate impingement sample densities to total impingement estimates based on per unit volume of MW pumped.
2.2.2 Entrainment Entrainment samples were collected during the 2014 spawning season from late April through August. Entrainment samples were collected using 0.5-meter conical plankton nets with 505µ mesh suspended from the forebay bridge, on the intake side of the log boom and within the hydraulic influence of the facility (Figure 1). It was assumed that organisms collected at that point would be entrained. Pairing of the nets provided replication at each depth (surface, and bottom) on each sampling date thereby increasing the reliability of the estimates. One set of samples (i.e., duplicate samples near the surface and near bottom) were collected during the day, at least one hour before sunset and the second set were collected at night, at least one hour after sunset to examine diel periodicity. Since barge traffic affected makeup water intake flow in the forebay, sampling was not conducted while barges passed the RSH.
A minimum of 50 cubic meters (m3) of water was filtered for each sample, with sampling duration ranging from 8 to 36 minutes. The volume of water sampled was determined by a General Oceanics (GO) Model 2030R flow meter placed at the mouth of each net. If the volume of water sampled was less than 50 m3 (less than 9,500 revolutions on the GO flow meter), the nets were redeployed and sampling continued until a minimum of 50 m3 of water was filtered.
4 DRAFT
At the conclusion of each tow, the nets were washed down to concentrate all debris, fish eggs, fish larvae, and early life stages of shellfish into the attached collection cups, and preserved in 5%-10%
formalin containing rose bengal.
Prior to sample collection, water temperature and velocity were measured at each sample depth.
The starting point for each tow was kept consistent throughout the study. Weather observations were also noted at the beginning of each sampling event, as well as significant changes (e.g., rapid rise/fall in air temperatures and thunderstorms) that may have occurred during the sampling event.
Ichthyoplankton (fish eggs, larvae, and juveniles) were hand sorted from the debris with the aid of illuminated magnifiers and/or dissecting microscopes. Ichthyoplankton were identified using a dissecting microscope equipped with polarizing lens.
Characters used to describe ichthyoplankton are qualitative, rather subjective, and change as early development progresses (e.g., pigmentation patterns). Quantitative characters such as myomere counts often show considerable overlap among species and can vary geographically and temporally for a given species (Bosley and Connor 1984). Thus, identifications for this study were made to the lowest practical taxon, which, for larval fish, sometimes was to the species level, but often to the genus level (e.g., Lepomis or Moxostoma cannot typically be separated to species), and occasionally higher levels (e.g., family). On occasion, species type identifications were made where a specimen agreed with the species to which it was assigned, but the taxonomist could not be 100 percent certain that it in fact it was that species. Thus, a species type designation may not be the species indicated, but rather a species that shares many of the same larval characteristics with that species. Fish eggs typically cannot be identified to species or genus, but family level egg identifications were provided when possible.
Identifications were made using current references and taxonomic keys (e.g., Auer 1982, Wallus et al. 1990, Kay et al. 1994, Simon and Wallus 2004) and selected specimens were verified by an outside consultant. Life stages of fish were categorized as egg, yolk-sac larvae, post yolk-sac larvae, and juveniles. Counts were made by taxon and life stage.
Operating conditions during each study were supplied by Exelon including intake water temperature, number, and duration of pumps operating, and makeup water (MW) volume pumped by hour for each sampling event, as well as daily, weekly, and monthly MW volume totals. MW volume data were used to extrapolate entrainment sample densities to total entrainment estimates based on per unit volume of MW pumped.
2.3 IMPINGEMENT DATA MANAGEMENT AND ANALYSIS 2.3.1 Data Management Field and laboratory data for each impingement sample were recorded on forms compatible for computer entry and all data processing activities were recorded on a log sheet for each batch of data.
Following serialization, diga-coding, and QA/QC checks, the data were manually entered into an Excel spreadsheet. All (i.e., 100 percent) of the manually entered data were then compared against 5
DRAFT
the hard copy field and laboratory data forms. All errors encountered were then corrected and the data managed in a SAS format (Version 8.2).
Data extrapolations and calculations were conducted to account for unmeasured (i.e., plus-counted) fish for generating length frequency distribution data for all fish occurring in any given sample.
Plus-counted fish were distributed equally among the representative individually measured fish by first assigning a length count of one to all measured fish in a given sample. Second, all plus-counted fish were distributed equally among the representative individually measured fish on a sample-specific and species-specific basis, by dividing the plus-counted fish by the number of fish measured to yield a length count adjustment factor. Third, the length count adjustment factor was then added to the length count to yield an extrapolated length count. The resultant length distributions were subsequently expanded based on weekly impingement extrapolations to provide annual and monthly distributions for the most commonly impinged species.
Appendix A provides a raw data listing by sampling event. The number, biomass, and relative abundance of shellfish and fish collected during each impingement sampling event are provided in Appendix B.
2.3.2 MakeupWater Volume and Water Temperature MW volumes and intake water temperatures provided by Exelon were summed on a per-sample event and period basis. Mean, minimum, and maximum water temperatures were calculated for each sampling period.
2.3.3 Impingement Estimates Tabular results were prepared that provided the number and weight of each taxon collected during each 24-hr impingement sampling event (Appendix B). These daily results were expanded based on makeup water flow for all operating units to yield weekly estimates, which when summed, yielded annual impingement estimates by species. The sampling period species-specific impingement estimates, both by number and by weight, were calculated using the following formula:
Volume MW Sampled Volume MW Collected (Biomass) or Weight Number Estimate Period x
=
The number and biomass extrapolations were based on the data summarized in Appendix B and were subsequently converted to catch per unit effort (CPE) or number/biomass impinged per MW use (Appendix C). These CPE data were then multiplied by the MW flows (Table 2-1) to yield estimates of the number and biomass of impinged organisms at LSCS over the course of the study (Appendix D).
Uncertainty in the resulting impingement estimate was addressed by computing 90% confidence intervals for each species expressed both as number of individuals and biomass. The impingement data for each period could not be fit to a parametric distribution; therefore nonparametric confidence intervals were computed using the Chebyshev Inequality (USEPA 2004).
6 DRAFT
The 90% confidence interval (CI) of the estimated average impingement was calculated using the Chebyshev Inequality (CI) as 1
CI 1
s n
=
where n
= number of samples (
)
52 n =
s
= standard deviation of the impingement estimates
= 0.10 for a 90% confidence interval The confidence limits on the total impingement during the 52-week study period were calculated as
(
)
(
)
(
)
(
)
0 if 0
(
)
if 0
(
)
tot tot n I CI LCL I n I CI n I CI UCL I n I CI
=
=
+
where
(
)
tot LCL I
= lower 90% confidence interval of total impingement
(
)
tot UCL I
= upper 90% confidence interval of total impingement 2.4 ENTRAINMENT DATA MANAGEMENT AND ANALYSIS 2.4.1 Data Management Management of entrainment data generally followed processing activities for the LSCS impingement study (Section 2.3.1). Field and laboratory data for each sample were recorded on forms compatible for computer entry and each data batch were recorded on a log sheet. Following serialization, diga-coding, and QA/QC checks, the data were manually entered into a spreadsheet.
All (i.e., 100 percent) of the manually entered data were then compared against the hard copy field and laboratory data forms. All errors encountered were then corrected and managed in a SAS format.
Tabular summaries that include total numbers, densities, and relative abundance by species or taxon were compiled from the laboratory data. MW volumes were summarized on a per-sample basis, as well as on a weekly (i.e., Sunday through Saturday), biweekly, and/or monthly basis.
Descriptive statistics (e.g., mean, minimum, and maximum values) were summarized for water temperature and DO. Tabular results were prepared for the average density of each taxon collected during each sampling event. These daily densities were then expanded based on MW volume to 7
DRAFT
yield period specific (i.e., weekly, biweekly, or monthly) estimates that were ultimately summed to yield total (i.e., April through August) estimates for 2014 (Table 2). The period-specific and taxon-specific entrainment estimates were calculated using the following formula:
Period Estimate = Daily Density x Period MW Volume 2.5 QUALITY ASSURANCE/QUALITY CONTROL Project specific QC activities included:
- Training - Staff collected and processed samples were adequately trained for their tasks.
This included familiarization with field and laboratory methods and any additional aspects that were required (e.g., equipment operation, processing/identification, site security and safety procedures);
- Equipment - All equipment used during this study were calibrated and maintained per the EA Quality Control and Procedures Manual or manufacturers recommendations.
Calibrations were appropriately documented;
- Laboratory - All samples were recorded on project-specific sample control sheets. Staff conducting identification of specimens had access to relevant taxonomic literature and a reference collection. A voucher collection of rare or unusual specimens was maintained with verification by a taxonomic expert; and
- Technical Assessments - An experienced senior staff member accompanied field personnel during the first sampling event to observe sampling activities and to verify that established methods were being followed. In addition, senior staff observed initial laboratory and data management activities to verify the same. Variances from approved procedures were corrected. Prior to the first scheduled sampling, a readiness review was conducted to ensure that trained personnel, and required equipment were in place.
8 DRAFT
9 DRAFT
FIGURES DRAFT
Figure 1. LaSalle County Station River Screen House (RSH) (Source Google Earth).
Illinois River Forebay Bridge and Log Boom Oil Boom Collection Basket LSCS RSH DRAFT
0 1
2 3
4 5
6 7
8 9
10 11 12 13 14 30 March-16 April 17 April-3 May 4-10 May 11-17 May 18-24 May 25-31 May 1-7 June 8-14 June 15-21 June 22-30 June 1-12 July 13-19 July 20-26 July 27 July-2 August 3-16 August 17-30 August Estimated Number Entrained x 1,000,000 Extrapolation Period Figure 2. Estimated Entrainment of Ichthyoplankton for Each Extrapolation Period at LaSalle County Station, 30 March - 30 August 2014.
Total Fish Eggs Total Fish Larvae Total Ichthyoplankton DRAFT
0 1
2 3
4 5
6 7
8 9
10 11 12 13 14 30 March-16 April 17 April-3 May 4-10 May 11-17 May 18-24 May 25-31 May 1-7 June 8-14 June 15-21 June 22-30 June 1-12 July 13-19 July 20-26 July 27 July-2 August 3-16 August 17-30 August Estimated Number Entrained x 1,000,000 Extrapolation Period Figure 3. Estimated Entrainment of Dominant Ichthyoplankton Taxa for Each Extrapolation Period at LaSalle County Station, 30 March - 30 August 2014.
Freshwater Drum Eggs Common Carp Eggs Other Fish Eggs Pimephales type Larvae Common Carp Larvae Other Cyprinidae Larvae Ictiobinae Larvae Other Larvae DRAFT
TABLES DRAFT
Table 1. Summary of Water Use during Impingement Sampling and Extrapolation Periods, LaSalle Station, April 2014 through March 2015.
Data for Impingment Sampling Events Extrapolation Data Sample Period Volume(a)
Period Volume(b)
Duration(c) 01-12 Apr 14 1,037 02-03 Apr 14 86.4 24.0 13-26 Apr 14 1,210 14-15 Apr 14 86.4 24.0 27 Apr-10 May 14 1,210 30 Apr-01 May 14 86.0 23.9 11-24 May 14 1,210 12-13 May 14 86.5 24.0 25 May-07 Jun 14 1,210 27-28 May 14 86.5 24.0 08-21 Jun 14 1,210 10-11 Jun 14 86.4 24.0 22 Jun-05 Jul 14 1,210 24-25 Jun 14 86.4 24.0 06-19 Jul 14 1,210 07-08 Jul 14 85.9 23.9 20 Jul-02 Aug 14 1,210 28-29 Jul 14 86.1 23.9 03-16 Aug 14 1,210 11-12 Aug 14 86.4 24.0 17-30 Aug 14 1,210 25-26 Aug 14 86.8 24.1 31 Aug-13 Sep 14 1,210 07-08 Sep 14 87.3 24.3 14 Sep-25 Oct 14 1,987 22-23 Sep 14 89.1 24.8 26 Oct-06 Dec 14 1,598 24-25 Nov 14 86.6 24.1 07-20 Dec 14 1,210 15-16 Dec 14 87.1 24.2 21 Dec-10 Jan 15 1,642 22-23 Dec 14 86.4 24.0 11-31 Jan 15 1,728 26-27 Jan 15 85.9 23.9 01-25 Feb 15 1,814 09-10 Feb 15 86.8 24.1 26 Feb-21 Mar 15 1,728 16-17 Mar 15 86.5 24.0 22-31 Mar 15 864 30-31 Mar 15 86.3 24.0 (a) Total makeup water volume, in millions of gallons, for each extrapolation period based on actual usage.
(b) Total sample volume, in millions of gallons for each 24-hour sampling period.
(c) Total sampling duration (hours) for each 24-hour sampling period.
DRAFT
Table 2. Summary of Makeup Water Use during Entrainment Sampling and Extrapolation Periods, LaSalle County Station, April through August 2014.
Data for Entrainment Sampling Events Extrapolation Data Sample No. Makeup Period Volume(a)
No. of Days(b)
Event Volume(c)
Pumps Volume(d) 30 March-16 April 1,555.2 18 3 April 0.120 2
86.4 17 April-03 May 1,468.8 17 24 April 0.127 2
86.4 4-10 May 604.8 7
6 May 0.134 2
86.4 11-17 May 604.8 7
13 May 0.121 2
86.4 18-24 May 604.8 7
20 May 0.142 2
86.4 25-31 May 604.8 7
28 May 0.115 2
86.4 1-7 June 604.8 7
3 June 0.116 2
86.4 8-14 June 604.8 7
11 June 0.116 2
86.4 15-21 June 604.8 7
17 June 0.111 2
86.4 22-30 June 777.6 9
24 June 0.121 2
86.4 1-12 July 1,036.8 12 9 July 0.125 2
86.4 13-19 July 604.8 7
15 July 0.120 2
86.4 20-26 July 604.8 7
22 July 0.116 2
86.4 27 July-2 August 604.8 7
29 July 0.140 2
86.4 3-16 August 1,209.6 14 12 August 0.117 2
86.4 17-30 August 1,209.6 14 26 August 0.120 2
86.4 (a) Total makeup water volume, in millions of gallons, for each extrapolation period.
(b) Number of days within extrapolation period.
(c) Total sample volume, in millions of gallons, for each event.
(d) Makeup water volume (MGD) during each sampling event.
DRAFT
24 Family Name Common Name Scientific Name(1)
Freshwater Crayfishes Orconectes Orconectes sp.
Northern Clearwater Orconectes propinquus Procambarus Procambarus sp.
Freshwater Mussels Fragile Papershell Leptodea fragilis Pink Heelsplitter Potamilus alatus Paper Pondshell Utterbackia imbecillis Freshwater Eels American Eel Anguilla rostrata Herrings Gizzard Shad Dorosoma cepedianum Threadfin Shad(2)
Dorosoma petenense Dorosoma Dorosoma sp.
Pikes And Central Mudminnow Umbra limi Grass Pickerel Esox americanus vermiculatus Carps And Minnows Goldfish(2)
Carassius auratus Common Carp(2)
Cyprinus carpio Hornyhead Chub Nocomis biguttatus Golden Shiner Notemigonus crysoleucas Emerald Shiner Notropis atherinoides Striped Shiner Luxilus chrysocephalus Spottail Shiner Notropis hudsonius Silverband Shiner Notropis shumardi Spotfin Shiner Cyprinella spiloptera Notropis Notropis sp.
Bluntnose Minnow Pimephales notatus Fathead Minnow Pimephales promelas Bullhead Minnow Pimephales vigilax Creek Chub Semotilus atromaculatus Cyprinidae Cyprinidae sp.
Suckers White Sucker Catostomus commersonii Smallmouth Buffalo Ictiobus bubalus Black Redhorse Moxostoma duquesnei Golden Redhorse Moxostoma erythrurum Loaches Oriental Weatherfish(2)
Misgurnus anguillicaudatus North American Black Bullhead Ameiurus melas Yellow Bullhead Ameiurus natalis Channel Catfish Ictalurus punctatus Freckled Madtom Noturus nocturnus Flathead Catfish Pylodictis olivaris New World Silversides Brook Silverside Labidesthes sicculus Temperate Basses Yellow Bass Morone mississippiensis Sunfishes Green Sunfish Lepomis cyanellus Warmouth Lepomis gulosus Orangespotted Sunfish Lepomis humilis Bluegill Lepomis macrochirus Lepomis Lepomis sp.
Smallmouth Bass Micropterus dolomieu Largemouth Bass Micropterus salmoides Black Crappie Pomoxis nigromaculatus Perches and Darters Banded Darter Etheostoma zonale Walleye Sander vitreus Sander Sander sp.
Drums and Croakers Freshwater Drum Aplodinotus grunniens Gobies Round Goby(2)
Neogobius melanostomus (1)Nomenclature follows Nelson et al. 2004.
(2)Introduced/Invasive species.
Table 3. Family, Common, and Scientific Names of Crayfish, Mussels, and Fishes Collected During Impingement Sampling at the LaSalle Station, April 2014 through March 2015 DRAFT
Table 4. Number and Biomass of Crayfish, Mussels, and Fish Collected During Impingement Sam at the LaSalle, April 2014 through March 2015.
Impingement Study Totals Number Caught Weight Caught Common Name No.
KG No.
Orconectes sp.
1 11.11%
0.003 7.89%
1 5.0%
Northern Clearwater Crayfish 7
77.78%
0.035 92.11%
5 25.0%
Procambarus sp.
1 11.11%
1 5.0%
Total Crayfish 9 100.00%
0.038 100.00%
Total Crayfish Species 2
Fragile Papershell 2
22.22%
0.003 17.65%
1 5.0%
Pink Heelsplitter 1
11.11%
0.001 5.88%
1 5.0%
Paper Pondshell 6
66.67%
0.013 76.47%
3 15.0%
Total Mussels 9 100.00%
0.017 100.00%
Total Mussel Species 3
American Eel 1
0.16%
0.746 8.36%
1 5.0%
Gizzard Shad 185 29.13%
1.614 18.09%
14 70.0%
Threadfin Shad(1) 59 9.29%
0.172 1.93%
8 40.0%
Dorosoma sp.
16 2.52%
0.027 0.30%
4 20.0%
Central Mudminnow 10 1.57%
0.050 0.56%
2 10.0%
Grass Pickerel 1
0.16%
0.008 0.09%
1 5.0%
Goldfish(1) 29 4.57%
0.173 1.94%
4 20.0%
Common Carp(1) 12 1.89%
0.832 9.32%
4 20.0%
Hornyhead Chub 1
0.16%
0.089 1.00%
1 5.0%
Golden Shiner 2
0.31%
0.011 0.12%
2 10.0%
Emerald Shiner 4
0.63%
0.016 0.18%
3 15.0%
Striped Shiner 2
0.31%
0.032 0.36%
2 10.0%
Spottail Shiner 12 1.89%
0.068 0.76%
4 20.0%
Silverband Shiner 1
0.16%
0.003 0.03%
1 5.0%
Spotfin Shiner 6
0.94%
0.020 0.22%
4 20.0%
Notropis sp.
1 0.16%
0.001 0.01%
1 5.0%
Bluntnose Minnow 33 5.20%
0.092 1.03%
4 20.0%
Fathead Minnow 2
0.31%
0.009 0.10%
2 10.0%
Bullhead Minnow 13 2.05%
0.042 0.47%
3 15.0%
Creek Chub 6
0.94%
0.022 0.25%
2 10.0%
Cyprinidae sp.
1 0.16%
0.001 0.01%
1 5.0%
White Sucker 5
0.79%
0.038 0.43%
1 5.0%
Smallmouth Buffalo 2
0.31%
1.268 14.21%
2 10.0%
Black Redhorse 1
0.16%
0.023 0.26%
1 5.0%
Golden Redhorse 2
0.31%
0.087 0.98%
2 10.0%
Oriental Weatherfish(1) 2 0.31%
0.063 0.71%
2 10.0%
Black Bullhead 9
1.42%
0.273 3.06%
4 20.0%
Yellow Bullhead 1
0.16%
0.005 0.06%
1 5.0%
Channel Catfish 10 1.57%
0.320 3.59%
7 35.0%
Freckled Madtom 1
0.16%
0.003 0.03%
1 5.0%
Flathead Catfish 2
0.31%
0.009 0.10%
2 10.0%
Brook Silverside 1
0.16%
0.002 0.02%
1 5.0%
Yellow Bass 3
0.47%
0.063 0.71%
3 15.0%
Green Sunfish 20 3.15%
0.083 0.93%
5 25.0%
Warmouth 1
0.16%
0.029 0.33%
1 5.0%
Orangespotted Sunfish 5
0.79%
0.031 0.35%
4 20.0%
Bluegill 41 6.46%
0.728 8.16%
14 70.0%
Lepomis sp.
1 0.16%
0.002 0.02%
1 5.0%
Smallmouth Bass 1
0.16%
0.204 2.29%
1 5.0%
Largemouth Bass 7
1.10%
0.034 0.38%
5 25.0%
Black Crappie 9
1.42%
0.037 0.41%
3 15.0%
Banded Darter 1
0.16%
0.001 0.01%
1 5.0%
Walleye 1
0.16%
0.382 4.28%
1 5.0%
Sander sp.
1 0.16%
0.001 0.01%
1 5.0%
Freshwater Drum 40 6.30%
0.717 8.04%
7 35.0%
Round Goby(1) 71 11.18%
0.492 5.51%
8 40.0%
Total Fish 635 100.00%
8.923 100.00%
Total Fish Species 41 Total Organisms 653 Total Species 46 Notes: Frequency of occurrence based on 20 sampling events.
(1) Introduced/Invasive species.
Frequency of Occurrence DRAFT
Table 5. Impingement Estimates at LaSalle Station, April 2014 through March 2015.
Common Name Estimated Count Estimated Weight (Kg)
Orconectes sp.
10 0.030 Northern Clearwater Crayfish 120 0.660 Procambarus sp.
14 Total Crayfish 144 0.690 Fragile Papershell 44 0.070 Pink Heelsplitter 14 0.010 Paper Pondshell 99 0.220 Total Mussels 157 0.300 American Eel 14 10.440 Gizzard Shad 3,245 29.650 Threadfin Shad(2) 985 3.020 Dorosoma sp.
242 0.430 Central Mudminnow 179 0.900 Grass Pickerel 14 0.110 Goldfish(2) 577 3.430 Common Carp(2) 174 12.110 Hornyhead Chub 13 1.240 Golden Shiner 23 0.140 Emerald Shiner 59 0.240 Striped Shiner 26 0.450 Spottail Shiner 195 1.120 Silverband Shiner 14 0.040 Spotfin Shiner 99 0.350 Notropis sp.
13 0.010 Bluntnose Minnow 459 1.290 Fathead Minnow 23 0.110 Bullhead Minnow 195 0.620 Creek Chub 91 0.350 CYPRINIDAE sp.
13 0.010 White Sucker 69 0.530 Smallmouth Buffalo 28 23.340 Black Redhorse 20 0.460 Golden Redhorse 26 1.220 Oriental Weatherfish(2) 27 0.880 Black Bullhead 152 5.090 Yellow Bullhead 13 0.070 Channel Catfish 151 4.490 Freckled Madtom 18 0.060 Flathead Catfish 26 0.130 Brook Silverside 10 0.020 Yellow Bass 45 0.910 Green Sunfish 365 1.440 Warmouth 18 0.540 Orangespotted Sunfish 75 0.460 Bluegill 695 13.370 Lepomis sp.
14 0.030 Smallmouth Bass 13 2.850 Largemouth Bass 111 0.580 Black Crappie 154 0.700 Banded Darter 13 0.010 Walleye 14 5.350 Sander sp.
14 0.010 Freshwater Drum 657 11.730 Round Goby(2) 991 6.890 Total Fish 10,372 147.220 Total Organisms 10,673 148.210 (1)Impingement estimates based on rated pump capacity.
(2) Introduced/invasive species.
DRAFT
Table 6. Monthly Length Frequency Distribution for Gizzard Shad Impinged at LaSalle Station, April 2014 - March 2015.
Length (mm)
APR 2014 MAY 2014 JUN 2014 JUL 2014 AUG 2014 SEP 2014 OCT 2014 NOV 2014 DEC 2014 JAN 2015 FEB 2015 MAR 2015 40 - 49 5
50 - 59 22 1
3 60 - 69 4
3 2
70 - 79 2
1 1
1 80 - 89 4
1 90 - 99 1
3 12 6
1 1
100 - 109 2
12 8
1 1
110 - 119 10 9
2 120 - 129 1
3 1
130 - 139 1
3 140 - 149 2
150 - 159 1
160 - 169 170 - 179 180 - 189 1
Total 2
33 7
9 1
41 31 4
4 Outage DRAFT
Table 7. Monthly Length Frequency Distribution for Threadfin Shad Impinged at LaSalle Station, April 2014 - March 2015.
Length (mm)
APR 2014 MAY 2014 JUN 2014 JUL 2014 AUG 2014 SEP 2014 OCT 2014 NOV 2014 DEC 2014 JAN 2015 FEB 2015 MAR 2015 50 - 59 3
6 9
60 - 69 9
3 3
11 70 - 79 8
80 - 89 2
90 - 99 1
100 - 109 1
1 Total 12 3
9 32 1
Outage DRAFT
Table 8. Monthly Length Frequency Distribution for Bluegill Impinged at LaSalle Station, April 2014 - March 2015.
Length (mm)
APR 2014 MAY 2014 JUN 2014 JUL 2014 AUG 2014 SEP 2014 OCT 2014 NOV 2014 DEC 2014 JAN 2015 FEB 2015 MAR 2015 30 - 39 2
40 - 49 1
1 3
1 50 - 59 1
1 1
1 1
1 2
60 - 69 1
1 1
1 1
1 70 - 79 1
2 80 - 89 1
1 1
90 - 99 1
100 - 109 1
110 - 119 1
1 1
120 - 129 130 - 139 1
1 1
140 - 149 2
1 150 - 159 1
160 - 169 1
Total 5
5 1
4 2
8 4
3 4
5 Outage DRAFT
Table 9. Monthly Length Frequency Distribution for Freswater Drum Impinged at LaSalle Station, April 2014 - March 2015.
Length (mm)
APR 2014 MAY 2014 JUN 2014 JUL 2014 AUG 2014 SEP 2014 OCT 2014 NOV 2014 DEC 2014 JAN 2015 FEB 2015 MAR 2015 90 - 99 2
1 2
100 - 109 1
4 2
1 1
110 - 119 1
5 4
120 - 129 1
2 2
130 - 139 3
1 1
140 - 149 3
150 - 159 1
1 160 - 169 1
Total 9
1 14 10 3
3 Outage DRAFT
Table 10. Monthly Length Frequency Distribution for Round Goby Impinged at LaSalle Station, April 2014 - March 2015.
Length (mm)
APR 2014 MAY 2014 JUN 2014 JUL 2014 AUG 2014 SEP 2014 OCT 2014 NOV 2014 DEC 2014 JAN 2015 FEB 2015 MAR 2015 50 - 59 1
60 - 69 5
3 1
70 - 79 14 6
1 1
80 - 89 10 8
1 90 - 99 2
7 Total 31 24 2
2 1
Outage DRAFT
Table 11. Length Frequency Distribution for Five Abundant Species Impinged at LaSalle Sta April 2014 - March 2015.
Length (mm)
Gizzard Shad Threadfin Shad Bluegill Freshwater Drum Round Goby 30 - 39 2
40 - 49 5
6 50 - 59 26 18 8
1 60 - 69 9
26 6
9 70 - 79 5
8 3
22 80 - 89 5
2 3
19 90 - 99 24 1
1 5
9 100 - 109 24 2
1 9
110 - 119 21 3
10 120 - 129 5
5 130 - 139 4
3 5
140 - 149 2
3 3
150 - 159 1
1 2
160 - 169 1
1 170 - 179 180 - 189 1
DRAFT
Table 12. Comparison of Length Data for Sportfish Impinged at LaSalle Station to Stock and Quality Length Categories.(1)
Length of Impinged Fish Length Categories Species N
Maximum Average Stock Quality Black Bullhead 9
163 112 122 218 Yellow Bullhead 1
69 69 81 147 Channel Catfish 10 293 128 239 432 Flathead Catfish 2
84 76 224 401 Bluegill 41 161 81 76 137 Smallmouth Bass 1
245 245 137 246 Largemouth Bass 7
83 67 165 297 Black Crappie 9
89 65 102 183 Walleye 1
355 355 208 376 Freshwater Drum 40 167 119 160 287 (1)Source for Stock and Quality Length Categories: Gablehouse 1984.
DRAFT
Table 13. Water Temperatures Recorded during Impingement Sampling Events, LaSalle Station, April 2014 through March 2015.
Intake Dissolved Temperature (C)
Oxygen (mg/L)
Period Min.
Mean Max.
Min.
Mean Max.
02-03 Apr 14 9.0 9.4 9.8 10.8 11.3 11.8 14-15 Apr 14 12.4 13.9 14.7 9.1 9.9 10.8 30 Apr-01 May 14 14.3 14.7 15.1 8.4 9.3 9.9 12-13 May 14 19.8 20.8 21.5 7.0 7.8 9.1 27-28 May 14 22.7 23.8 24.5 6.2 7.3 8.1 10-11 Jun 14 21.6 23.1 24.6 7.6 8.7 11.3 24-25 Jun 14 24.5 25.2 26.0 07-08 Jul 14 24.6 25.7 26.6 7.5 7.9 8.2 28-29 Jul 14 26.2 26.9 27.3 11-12 Aug 14 27.2 27.6 28.0 7.0 7.7 8.5 25-26 Aug 14 25.7 26.8 27.6 6.3 7.0 7.2 07-08 Sep 14 25.8 26.3 26.7 6.9 7.2 7.6 22-23 Sep 14 20.1 20.6 21.0 8.3 8.7 9.2 24-25 Nov 14 4.4 5.6 7.3 11.5 12.3 13.2 15-16 Dec 14 6.0 6.5 6.8 22-23 Dec 14 4.9 5.6 6.8 26-27 Jan 15 1.6 1.8 2.2 13.9 14.3 14.4 09-10 Feb 15 3.3 3.7 4.0 13.8 14.0 14.4 16-17 Mar 15 8.1 9.1 9.9 11.6 11.9 12.1 30-31 Mar 15 7.2 8.2 9.2 12.6 13.2 13.5 DRAFT
Table 14. Number and Relative Abundance of Ichthyoplankton Taxa Collected during Entrainment Sampling at LaSalle County Station, 3 April - 26 August 2014.
Common Occurrence(3)
Family Name Taxa Life Stage No.
No.
GARS GAR sp.(1)
Post Yolk-sac 3
0.04 2
13%
HERRINGS Dorosoma sp.
Yolk-sac 19 0.27 4
25%
Post Yolk-sac 230 3.23 12 75%
GIZZARD SHAD(1)
Juvenile 5
0.07 3
19%
CARPS and MINNOWS CYPRINIDAE sp.
Egg 22 0.31 1
6%
Yolk-sac 1,618 22.74 13 81%
Post Yolk-sac 25 0.35 2
13%
COMMON CARP(1)
Egg 431 6.06 8
50%
Yolk-sac 895 12.58 10 63%
Post Yolk-sac 2
0.03 2
13%
Juvenile 1
0.01 1
6%
Hypophthalmichthys type(1)
Egg 35 0.49 3
19%
Notropis sp.(1)
Juvenile 4
0.06 1
6%
Pimephales sp.
Juvenile 1
0.01 1
6%
BLUNTNOSE MINNOW(1)
Post Yolk-sac 1
0.01 1
6%
Juvenile 4
0.06 2
13%
BULLHEAD MINNOW(1)
Juvenile 2
0.03 1
6%
Pimephales type(1)
Yolk-sac 693 9.74 10 63%
Post Yolk-sac 4
0.06 2
13%
Semotilus type(1)
Yolk-sac 32 0.45 3
19%
Post Yolk-sac 8
0.11 2
13%
SUCKERS CATOSTOMIDAE sp.
Yolk-sac 4
0.06 2
13%
ICTIOBINAE sp.(2)
Yolk-sac 1,750 24.60 10 63%
Post Yolk-sac 52 0.73 5
31%
Juvenile 2
0.03 1
6%
Moxostoma sp.(1)
Yolk-sac 28 0.39 2
13%
Post Yolk-sac 19 0.27 6
38%
NORTH AMERICAN CATFISHES CHANNEL CATFISH(1)
Juvenile 16 0.22 2
13%
NEW WORLD SILVERSIDES BROOK SILVERSIDE(1)
Yolk-sac 2
0.03 1
6%
TOPMINNOWS BLACKSTRIPE TOPMINNOW(1)
Yolk-sac 1
0.01 1
6%
Juvenile 1
0.01 1
6%
BANDED KILLIFISH(1)
Juvenile 1
0.01 1
6%
TEMPERATE BASSES Morone sp.(1)
Yolk-sac 7
0.10 3
19%
SUNFISHES ROCK BASS(1)
Post Yolk-sac 2
0.03 1
6%
Lepomis sp.
Yolk-sac 1
0.01 1
6%
Post Yolk-sac 8
0.11 5
31%
Juvenile 19 0.27 1
6%
GREEN SUNFISH(1)
Juvenile 1
0.01 1
6%
PUMPKINSEED type(1)
Yolk-sac 44 0.62 9
56%
Post Yolk-sac 6
0.08 4
25%
Juvenile 2
0.03 1
6%
BLUEGILL type(1)
Post Yolk-sac 3
0.04 1
6%
LARGEMOUTH BASS(1)
Juvenile 1
0.01 1
6%
PERCHES AND DARTERS DARTER sp.(1)
Yolk-sac 125 1.76 8
50%
Post Yolk-sac 30 0.42 7
44%
Juvenile 2
0.03 1
6%
LOGPERCH type(1)
Yolk-sac 166 2.33 11 69%
Post Yolk-sac 2
0.03 1
6%
Sander sp.
Yolk-sac 40 0.56 5
31%
Post Yolk-sac 1
0.01 1
6%
WALLEYE(1)
Post Yolk-sac 1
0.01 1
6%
DRUMS AND CROAKERS FRESHWATER DRUM(1)
Egg 480 6.75 10 63%
Yolk-sac 15 0.21 6
38%
Post Yolk-sac 20 0.28 3
19%
Juvenile 1
0.01 1
6%
GOBIES ROUND GOBY(1)
Juvenile 147 2.07 7
44%
UNIDENTIFIED UNIDENTIFIED Egg 42 0.59 4
25%
Yolk-sac 26 0.37 9
56%
Larvae 2
0.03 1
6%
Morone /Pomoxis type Egg 9
0.13 2
13%
TOTAL ICHTHYOPLANKTON 7,114 100.00 TOTAL TAXA 27 (1) Counted as one taxa.
(2) Counted as two taxa.
(3)Occurences based on 16 sampling events.
DRAFT
Table 15. Ichthyoplankton Taxa Entrainment Estimates for LaSalle County Station, 30 March-30 August 2014.
Common Family Name Taxa Life Stage No.
GARS GAR sp.(1)
Post Yolk-sac 21,847 0.06 HERRINGS Dorosoma sp.
Yolk-sac 102,868 0.27 Post Yolk-sac 1,280,881 3.36 GIZZARD SHAD(1)
Juvenile 32,604 0.09 CARPS and MINNOWS CYPRINIDAE sp.
Egg 115,919 0.30 Yolk-sac 8,694,914 22.83 Post Yolk-sac 201,993 0.53 COMMON CARP(1)
Egg 2,258,280 5.93 Yolk-sac 4,606,691 12.10 Post Yolk-sac 9,514 0.02 Juvenile 5,023 0.01 Hypophthalmichthys type(1)
Egg 236,214 0.62 Notropis sp.(1)
Juvenile 40,367 0.11 Pimephales sp.
Juvenile 10,092 0.03 BLUNTNOSE MINNOW(1)
Post Yolk-sac 5,203 0.01 Juvenile 23,377 0.06 BULLHEAD MINNOW(1)
Juvenile 20,183 0.05 Pimephales type(1)
Yolk-sac 4,015,245 10.54 Post Yolk-sac 27,047 0.07 Semotilus type(1)
Yolk-sac 156,787 0.41 Post Yolk-sac 34,918 0.09 SUCKERS CATOSTOMIDAE sp.
Yolk-sac 20,064 0.05 ICTIOBINAE sp.(2)
Yolk-sac 8,787,557 23.08 Post Yolk-sac 244,824 0.64 Juvenile 12,839 0.03 Moxostoma sp.(1)
Yolk-sac 127,322 0.33 Post Yolk-sac 97,426 0.26 NORTH AMERICAN CATFISHES CHANNEL CATFISH(1)
Juvenile 93,570 0.25 NEW WORLD SILVERSIDES BROOK SILVERSIDE(1)
Yolk-sac 12,839 0.03 TOPMINNOWS BLACKSTRIPE TOPMINNOW(1)
Yolk-sac 6,419 0.02 Juvenile 6,419 0.02 BANDED KILLIFISH(1)
Juvenile 5,023 0.01 TEMPERATE BASSES Morone sp.(1)
Yolk-sac 67,537 0.18 SUNFISHES ROCK BASS(1)
Post Yolk-sac 10,402 0.03 Lepomis sp.
Yolk-sac 5,023 0.01 Post Yolk-sac 48,267 0.13 Juvenile 95,441 0.25 GREEN SUNFISH(1)
Juvenile 5,436 0.01 PUMPKINSEED type(1)
Yolk-sac 246,922 0.65 Post Yolk-sac 44,029 0.12 Juvenile 16,646 0.04 BLUEGILL type(1)
Post Yolk-sac 15,610 0.04 LARGEMOUTH BASS(1)
Juvenile 6,419 0.02 PERCHES AND DARTERS DARTER sp.(1)
Yolk-sac 637,264 1.67 Post Yolk-sac 161,981 0.43 Juvenile 12,839 0.03 LOGPERCH type(1)
Yolk-sac 983,554 2.58 Post Yolk-sac 10,538 0.03 Sander sp.
Yolk-sac 376,707 0.99 Post Yolk-sac 5,014 0.01 WALLEYE(1)
Post Yolk-sac 5,014 0.01 DRUMS AND CROAKERS FRESHWATER DRUM(1)
Egg 2,501,615 6.57 Yolk-sac 80,355 0.21 Post Yolk-sac 122,255 0.32 Juvenile 6,419 0.02 GOBIES ROUND GOBY(1)
Juvenile 874,780 2.30 UNIDENTIFIED UNIDENTIFIED Egg 215,261 0.57 Yolk-sac 154,989 0.41 Larvae 10,027 0.03 Morone /Pomoxis type Egg 44,351 0.12 TOTAL ICHTHYOPLANKTON 38,078,968 100.00 TOTAL TAXA 27 (1) Counted as one taxa.
(2) Counted as two taxa.
DRAFT
Table 16. Diel Comparisons of the Number, Density, and Relative Abundance of Ichthyoplankton Collected during Entrainment Sampling at LaSalle County Station, 3 April - 26 August 2014.
Day Night Taxa Life Stage No.
Den.
No.
Den.
GAR sp.
Post Yolk-sac 1
1.0 0.04 2
2.0 0.05 GIZZARD SHAD Juvenile 1
1.0 0.04 4
4.0 0.09 Dorosoma sp.
Yolk-sac 18 18.5 0.64 1
1.0 0.02 Post Yolk-sac 111 114.3 3.95 119 120.1 2.76 COMMON CARP Egg 319 328.5 11.35 112 113.0 2.60 Yolk-sac 228 234.8 8.11 667 672.9 15.50 Post Yolk-sac 1
1.0 0.04 1
1.0 0.02 Juvenile 1
1.0 0.02 Hypophthalmichthys type Egg 24 24.7 0.85 11 11.1 0.26 Notropis sp.
Juvenile 1
1.0 0.04 3
3.0 0.07 BLUNTNOSE MINNOW Post Yolk-sac 1
1.0 0.02 Juvenile 4
4.0 0.09 BULLHEAD MINNOW Juvenile 2
2.0 0.05 Pimephales type Yolk-sac 169 174.0 6.01 524 528.6 12.17 Post Yolk-sac 2
2.1 0.07 2
2.0 0.05 Pimephales sp.
Juvenile 1
1.0 0.02 Semotilus type Yolk-sac 7
7.2 0.25 25 25.2 0.58 Post Yolk-sac 8
8.1 0.19 CYPRINIDAE sp.
Egg 22 22.7 0.78 Yolk-sac 982 1,011.2 34.95 636 641.6 14.78 Post Yolk-sac 11 11.3 0.39 14 14.1 0.33 Moxostoma sp.
Yolk-sac 2
2.1 0.07 26 26.2 0.60 Post Yolk-sac 4
4.1 0.14 15 15.1 0.35 ICTIOBINAE sp.
Yolk-sac 429 441.8 15.27 1,321 1,332.7 30.69 Post Yolk-sac 6
6.2 0.21 46 46.4 1.07 Juvenile 2
2.0 0.05 CATOSTOMIDAE sp.
Yolk-sac 4
4.1 0.14 CHANNEL CATFISH Juvenile 16 16.1 0.37 BANDED KILLIFISH Juvenile 1
1.0 0.02 BLACKSTRIPE TOPMINNOW Yolk-sac 1
1.0 0.04 Juvenile 1
1.0 0.02 BROOK SILVERSIDE Yolk-sac 2
2.0 0.05 Morone sp.
Yolk-sac 6
6.2 0.21 1
1.0 0.02 ROCK BASS Post Yolk-sac 1
1.0 0.04 1
1.0 0.02 GREEN SUNFISH Juvenile 1
1.0 0.02 BLUEGILL type Post Yolk-sac 3
3.0 0.07 PUMPKINSEED type Yolk-sac 12 12.4 0.43 32 32.3 0.74 Post Yolk-sac 6
6.1 0.14 Juvenile 2
2.0 0.05 Lepomis sp.
Yolk-sac 1
1.0 0.04 Post Yolk-sac 3
3.1 0.11 5
5.0 0.12 Juvenile 19 19.2 0.44 LARGEMOUTH BASS Juvenile 1
1.0 0.02 WALLEYE Post Yolk-sac 1
1.0 0.02 Sander sp.
Yolk-sac 2
2.1 0.07 38 38.3 0.88 Post Yolk-sac 1
1.0 0.04 LOGPERCH type Yolk-sac 63 64.9 2.24 103 103.9 2.39 Post Yolk-sac 2
2.1 0.07 DARTER sp.
Yolk-sac 37 38.1 1.32 88 88.8 2.04 Post Yolk-sac 10 10.3 0.36 20 20.2 0.46 Juvenile 2
2.0 0.05 FRESHWATER DRUM Egg 286 294.5 10.18 194 195.7 4.51 Yolk-sac 8
8.2 0.28 7
7.1 0.16 Post Yolk-sac 2
2.1 0.07 18 18.2 0.42 Juvenile 1
1.0 0.02 ROUND GOBY Juvenile 1
1.0 0.04 146 147.3 3.39 Morone /Pomoxis type Egg 2
2.1 0.07 7
7.1 0.16 UNIDENTIFIED Egg 19 19.6 0.68 23 23.2 0.53 Yolk-sac 11 11.3 0.39 15 15.1 0.35 Larvae 2
2.0 0.05 TOTAL ICHTHYOPLANKTON 2,810 2,893.6 100.00 4,304 4,342.1 100.00 Note: Density (Den.) is No. per million gallons.
DRAFT
Table 17. Diel Comparisons of the Number, Density, and Relative Abundance of Ichthyoplankton Collected during Each Entrainment Sampling Event at LaSalle County Station, 3 April - 26 August 2015.
3 April Day Night Taxa Life Stage No.
Den.
No.
Den.
FRESHWATER DRUM Egg 1
16.0 100.00 24 April Day Night Taxa Life Stage No.
Den.
No.
Den.
Dorosoma sp.
Post Yolk-sac 3
46.2 14.29 ICTIOBINAE sp.
Yolk-sac 1
16.1 2.5 Morone sp.
Yolk-sac 4
61.6 19.05 1
16.1 2.5 Sander sp.
Yolk-sac 27 433.8 67.5 LOGPERCH type Yolk-sac 13 200.3 61.9 10 160.7 25 UNIDENTIFIED Yolk-sac 1
15.4 4.76 1
16.1 2.5 TOTAL ICHTHYOPLANKTON 21 323.6 100.00 40 642.7 100.00 6 May Day Night Taxa Life Stage No.
Den.
No.
Den.
Dorosoma sp.
Yolk-sac 1
16.4 1.47 Post Yolk-sac 7
95.5 35.00 ICTIOBINAE sp.
Yolk-sac 7
95.5 35.00 62 1,015.2 91.18 Morone sp.
Yolk-sac 1
13.6 5.00 Sander sp.
Yolk-sac 1
13.6 5.00 1
16.4 1.47 LOGPERCH type Yolk-sac 4
54.6 20.00 UNIDENTIFIED Yolk-sac 4
65.5 5.88 TOTAL ICHTHYOPLANKTON 20 272.8 100.00 68 1,113.5 100.00 13 May Day Night Taxa Life Stage No.
Den.
No.
Den.
Dorosoma sp.
Post Yolk-sac 7
118.6 0.98 6
97.4 0.31 COMMON CARP Egg 5
84.7 0.70 7
113.6 0.37 Yolk-sac 187 3,169.6 26.15 490 7,950.4 25.67 Semotilus type Yolk-sac 6
101.7 0.84 20 324.5 1.05 CYPRINIDAE sp.
Yolk-sac 12 203.4 1.68 133 2,158.0 6.97 Moxostoma sp.
Yolk-sac 1
16.9 0.14 10 162.3 0.52 Post Yolk-sac 2
33.9 0.28 1
16.2 0.05 ICTIOBINAE sp.
Yolk-sac 351 5,949.4 49.09 1,009 16,371.4 52.85 Post Yolk-sac 6
101.7 0.84 20 324.5 1.05 CATOSTOMIDAE sp.
Yolk-sac 3
50.8 0.42 PUMPKINSEED type Yolk-sac 3
48.7 0.16 WALLEYE Post Yolk-sac 1
16.2 0.05 Sander sp.
Yolk-sac 9
146.0 0.47 Post Yolk-sac 1
16.9 0.14 LOGPERCH type Yolk-sac 31 525.4 4.34 71 1,152.0 3.72 DARTER sp.
Yolk-sac 15 254.2 2.10 45 730.1 2.36 Post Yolk-sac 2
33.9 0.28 FRESHWATER DRUM Egg 71 1,203.4 9.93 52 843.7 2.72 UNIDENTIFIED Egg 12 203.4 1.68 23 373.2 1.20 Yolk-sac 3
50.8 0.42 7
113.6 0.37 Larvae 2
32.5 0.10 TOTAL ICHTHYOPLANKTON 715 12,119.2 100.00 1,909 30,974.2 100.00 DRAFT
Table 17 (cont.)
20 May Day Night Taxa Life Stage No.
Den.
No.
Den.
COMMON CARP Egg 1
14.7 2.94 1
13.4 0.72 Yolk-sac 2
26.8 1.45 Post Yolk-sac 1
13.4 0.72 Semotilus type Yolk-sac 1
14.7 2.94 4
53.6 2.90 Post Yolk-sac 7
93.9 5.07 CYPRINIDAE sp.
Yolk-sac 4
58.9 11.76 10 134.1 7.25 Moxostoma sp.
Yolk-sac 1
14.7 2.94 16 214.5 11.59 Post Yolk-sac 2
26.8 1.45 ICTIOBINAE sp.
Yolk-sac 14 206.2 41.18 46 616.8 33.33 Post Yolk-sac 23 308.4 16.67 LOGPERCH type Yolk-sac 6
88.4 17.65 7
93.9 5.07 DARTER sp.
Yolk-sac 4
58.9 11.76 17 227.9 12.32 Post Yolk-sac 1
13.4 0.72 FRESHWATER DRUM Egg 1
14.7 2.94 Morone /Pomoxis type Egg 2
29.5 5.88 1
13.4 0.72 TOTAL ICHTHYOPLANKTON 34 500.9 100.00 138 1,850.4 100.00 28 May Day Night Taxa Life Stage No.
Den.
No.
Den.
Dorosoma sp.
Post Yolk-sac 11 192.2 4.72 6
104.3 1.54 COMMON CARP Yolk-sac 19 332.0 8.15 95 1,650.8 24.42 Post Yolk-sac 1
17.5 0.43 BLUNTNOSE MINNOW Juvenile 2
34.8 0.51 CYPRINIDAE sp.
Egg 22 384.4 9.44 Yolk-sac 115 2,009.3 49.36 36 625.6 9.25 Moxostoma sp.
Post Yolk-sac 2
34.8 0.51 ICTIOBINAE sp.
Yolk-sac 40 698.9 17.17 184 3,197.3 47.30 Morone sp.
Yolk-sac 1
17.5 0.43 PUMPKINSEED type Yolk-sac 2
34.8 0.51 LOGPERCH type Yolk-sac 3
52.4 1.29 4
69.5 1.03 Post Yolk-sac 2
34.9 0.86 DARTER sp.
Yolk-sac 2
34.9 0.86 3
52.1 0.77 FRESHWATER DRUM Egg 17 297.0 7.30 9
156.4 2.31 ROUND GOBY Juvenile 40 695.1 10.28 Morone /Pomoxis type Egg 6
104.3 1.54 TOTAL ICHTHYOPLANKTON 233 4,070.9 100.00 389 6,759.5 100.00 3 June Day Night Taxa Life Stage No.
Den.
No.
Den.
Dorosoma sp.
Yolk-sac 2
33.8 0.33 Post Yolk-sac 22 371.9 3.61 25 438.0 6.14 COMMON CARP Yolk-sac 3
50.7 0.49 5
87.6 1.23 BLUNTNOSE MINNOW Post Yolk-sac 1
17.5 0.25 Pimephales type Yolk-sac 51 893.5 12.53 Semotilus type Yolk-sac 1
17.5 0.25 CYPRINIDAE sp.
Yolk-sac 439 7,421.4 72.09 157 2,750.6 38.57 Moxostoma sp.
Post Yolk-sac 2
35.0 0.49 ICTIOBINAE sp.
Yolk-sac 1
17.5 0.25 Post Yolk-sac 1
17.5 0.25 BLUEGILL type Post Yolk-sac 3
52.6 0.74 PUMPKINSEED type Yolk-sac 2
33.8 0.33 2
35.0 0.49 Lepomis sp.
Post Yolk-sac 1
16.9 0.16 Sander sp.
Yolk-sac 1
16.9 0.16 LOGPERCH type Yolk-sac 1
17.5 0.25 DARTER sp.
Yolk-sac 3
50.7 0.49 6
105.1 1.47 Post Yolk-sac 1
17.5 0.25 FRESHWATER DRUM Egg 135 2,282.2 22.17 114 1,997.3 28.01 Yolk-sac 3
52.6 0.74 Post Yolk-sac 1
16.9 0.16 ROUND GOBY Juvenile 30 525.6 7.37 UNIDENTIFIED Yolk-sac 3
52.6 0.74 TOTAL ICHTHYOPLANKTON 609 10,295.3 100.00 407 7,130.7 100.00 DRAFT
Table 17 (cont.)
11 June Day Night Taxa Life Stage No.
Den.
No.
Den.
GAR sp.
Post Yolk-sac 1
17.5 0.23 Dorosoma sp.
Post Yolk-sac 17 297.7 3.99 22 371.7 8.98 COMMON CARP Egg 274 4,799.0 64.32 71 1,199.4 28.98 Yolk-sac 5
87.6 1.17 21 354.8 8.57 Pimephales type Yolk-sac 9
157.6 2.11 31 523.7 12.65 Post Yolk-sac 2
35.0 0.47 Semotilus type Post Yolk-sac 1
16.9 0.41 CYPRINIDAE sp.
Yolk-sac 44 770.6 10.33 56 946.0 22.86 Post Yolk-sac 11 192.7 2.58 Moxostoma sp.
Post Yolk-sac 2
35.0 0.47 4
67.6 1.63 ICTIOBINAE sp.
Post Yolk-sac 1
16.9 0.41 ROCK BASS Post Yolk-sac 1
17.5 0.23 1
16.9 0.41 PUMPKINSEED type Yolk-sac 3
52.5 0.70 1
16.9 0.41 LOGPERCH type Yolk-sac 5
87.6 1.17 1
16.9 0.41 DARTER sp.
Yolk-sac 1
17.5 0.23 2
33.8 0.82 Post Yolk-sac 5
87.6 1.17 5
84.5 2.04 FRESHWATER DRUM Egg 44 770.6 10.33 8
135.1 3.27 ROUND GOBY Juvenile 1
17.5 0.23 20 337.9 8.16 UNIDENTIFIED Yolk-sac 1
17.5 0.23 TOTAL ICHTHYOPLANKTON 426 7,461.2 100.00 245 4,138.9 100.00 17 June Day Night Taxa Life Stage No.
Den.
No.
Den.
Dorosoma sp.
Yolk-sac 15 273.4 2.79 Post Yolk-sac 25 455.6 4.66 28 496.6 8.24 COMMON CARP Egg 17 309.8 3.17 22 390.2 6.47 Yolk-sac 3
54.7 0.56 Pimephales type Yolk-sac 111 2,022.9 20.67 123 2,181.4 36.18 CYPRINIDAE sp.
Yolk-sac 324 5,904.8 60.34 103 1,826.7 30.29 Moxostoma sp.
Post Yolk-sac 4
70.9 1.18 ICTIOBINAE sp.
Yolk-sac 15 273.4 2.79 9
159.6 2.65 GREEN SUNFISH Juvenile 1
17.7 0.29 PUMPKINSEED type Yolk-sac 3
54.7 0.56 4
70.9 1.18 Post Yolk-sac 2
35.5 0.59 Lepomis sp.
Post Yolk-sac 1
18.2 0.19 Sander sp.
Yolk-sac 1
17.7 0.29 LOGPERCH type Yolk-sac 2
35.5 0.59 DARTER sp.
Yolk-sac 7
127.6 1.30 10 177.3 2.94 Post Yolk-sac 2
36.4 0.37 9
159.6 2.65 FRESHWATER DRUM Egg 12 218.7 2.23 4
70.9 1.18 Yolk-sac 1
18.2 0.19 1
17.7 0.29 Post Yolk-sac 5
88.7 1.47 ROUND GOBY Juvenile 12 212.8 3.53 UNIDENTIFIED Yolk-sac 1
18.2 0.19 TOTAL ICHTHYOPLANKTON 537 9,786.6 100.00 340 6,029.8 100.00 24 June Day Night Taxa Life Stage No.
Den.
No.
Den.
GIZZARD SHAD Juvenile 3
45.4 1.02 Dorosoma sp.
Yolk-sac 1
18.2 0.84 Post Yolk-sac 17 308.7 14.29 22 333.0 7.48 COMMON CARP Egg 2
36.3 1.68 6
90.8 2.04 Yolk-sac 11 199.8 9.24 47 711.3 15.99 Hypophthalmichthys type Egg 19 345.1 15.97 11 166.5 3.74 BLUNTNOSE MINNOW Juvenile 2
30.3 0.68 Pimephales type Yolk-sac 36 653.8 30.25 100 1,513.5 34.01 CYPRINIDAE sp.
Yolk-sac 19 345.1 15.97 40 605.4 13.61 ICTIOBINAE sp.
Yolk-sac 6
90.8 2.04 Post Yolk-sac 1
15.1 0.34 Juvenile 2
30.3 0.68 BLACKSTRIPE TOPMINNOW Yolk-sac 1
18.2 0.84 Juvenile 1
15.1 0.34 DRAFT
Table 17 (cont.)
24 June (cont.)
Day Night Taxa (cont.)
Life Stage No.
Den.
No.
Den.
BROOK SILVERSIDE Yolk-sac 2
30.3 0.68 PUMPKINSEED type Yolk-sac 3
54.5 2.52 6
90.8 2.04 Post Yolk-sac 1
15.1 0.34 Lepomis sp.
Post Yolk-sac 3
45.4 1.02 LARGEMOUTH BASS Juvenile 1
15.1 0.34 LOGPERCH type Yolk-sac 4
60.5 1.36 DARTER sp.
Yolk-sac 4
72.6 3.36 5
75.7 1.70 Post Yolk-sac 1
18.2 0.84 3
45.4 1.02 Juvenile 2
30.3 0.68 FRESHWATER DRUM Egg 3
54.5 2.52 Post Yolk-sac 1
18.2 0.84 13 196.8 4.42 Juvenile 1
15.1 0.34 ROUND GOBY Juvenile 12 181.6 4.08 UNIDENTIFIED Yolk-sac 1
18.2 0.84 TOTAL ICHTHYOPLANKTON 119 2,161.2 100.00 294 4,449.7 100.00 9 July Day Night Taxa Life Stage No.
Den.
No.
Den.
GAR sp.
Post Yolk-sac 2
30.6 1.90 GIZZARD SHAD Juvenile 1
16.9 8.33 Dorosoma sp.
Post Yolk-sac 3
45.9 2.86 COMMON CARP Egg 2
33.7 16.67 1
15.3 0.95 Yolk-sac 1
15.3 0.95 Hypophthalmichthys type Egg 4
67.5 33.33 Pimephales type Yolk-sac 1
16.9 8.33 31 474.8 29.52 Post Yolk-sac 2
30.6 1.90 CYPRINIDAE sp.
Yolk-sac 20 306.3 19.05 ICTIOBINAE sp.
Yolk-sac 1
16.9 8.33 3
45.9 2.86 CHANNEL CATFISH Juvenile 4
61.3 3.81 PUMPKINSEED type Post Yolk-sac 2
30.6 1.90 Juvenile 2
30.6 1.90 Lepomis sp.
Post Yolk-sac 1
16.9 8.33 LOGPERCH type Yolk-sac 1
16.9 8.33 DARTER sp.
Yolk-sac 1
16.9 8.33 FRESHWATER DRUM Egg 4
61.3 3.81 Yolk-sac 1
15.3 0.95 ROUND GOBY Juvenile 29 444.1 27.62 TOTAL ICHTHYOPLANKTON 12 202.4 100.00 105 1,608.1 100.00 15 July Day Night Taxa Life Stage No.
Den.
No.
Den.
GIZZARD SHAD Juvenile 1
16.2 0.54 Dorosoma sp.
Post Yolk-sac 2
34.2 5.00 4
64.7 2.17 COMMON CARP Egg 13 222.0 32.50 4
64.7 2.17 Yolk-sac 5
80.8 2.72 Juvenile 1
16.2 0.54 Pimephales type Yolk-sac 6
102.5 15.00 87 1,406.6 47.28 CYPRINIDAE sp.
Yolk-sac 12 205.0 30.00 29 468.9 15.76 CATOSTOMIDAE sp.
Yolk-sac 1
17.1 2.50 CHANNEL CATFISH Juvenile 12 194.0 6.52 BANDED KILLIFISH Juvenile 1
16.2 0.54 PUMPKINSEED type Yolk-sac 10 161.7 5.43 Lepomis sp.
Yolk-sac 1
17.1 2.50 Post Yolk-sac 2
32.3 1.09 Juvenile 19 307.2 10.33 LOGPERCH type Yolk-sac 3
48.5 1.63 DARTER sp.
Post Yolk-sac 1
16.2 0.54 FRESHWATER DRUM Egg 3
51.2 7.50 2
32.3 1.09 Yolk-sac 2
34.2 5.00 ROUND GOBY Juvenile 3
48.5 1.63 TOTAL ICHTHYOPLANKTON 40 683.2 100.00 184 2,974.9 100.00 DRAFT
Table 17 (cont.)
22 July Day Night Taxa (cont.)
Life Stage No.
Den.
No.
Den.
Pimephales type Yolk-sac 5
87.1 31.25 25 424.0 75.76 CYPRINIDAE sp.
Yolk-sac 1
17.4 6.25 6
101.8 18.18 FRESHWATER DRUM Yolk-sac 4
69.6 25.00 2
33.9 6.06 UNIDENTIFIED Egg 4
69.6 25.00 Yolk-sac 2
34.8 12.50 TOTAL ICHTHYOPLANKTON 16 278.6 100.00 33 559.7 100.00 29 July Day Night Taxa Life Stage No.
Den.
No.
Den.
Dorosoma sp.
Post Yolk-sac 2
27.3 2.56 COMMON CARP Egg 5
75.3 23.81 Yolk-sac 1
13.6 1.28 Pimephales type Yolk-sac 1
15.1 4.76 47 640.5 60.26 CYPRINIDAE sp.
Yolk-sac 10 150.7 47.62 26 354.3 33.33 ICTIOBINAE sp.
Yolk-sac 1
15.1 4.76 PUMPKINSEED type Yolk-sac 1
15.1 4.76 2
27.3 2.56 FRESHWATER DRUM Yolk-sac 1
15.1 4.76 UNIDENTIFIED Egg 2
30.1 9.52 TOTAL ICHTHYOPLANKTON 21 316.4 100.00 78 1,063.0 100.00 12 August Day Night Taxa Life Stage No.
Den.
No.
Den.
Dorosoma sp.
Post Yolk-sac 1
17.2 1.54 Hypophthalmichthys type Egg 1
17.0 25.00 Pimephales type Yolk-sac 28 480.5 43.08 CYPRINIDAE sp.
Yolk-sac 20 343.2 30.77 Post Yolk-sac 14 240.2 21.54 PUMPKINSEED type Yolk-sac 2
34.3 3.08 UNIDENTIFIED Egg 1
17.0 25.00 Yolk-sac 2
34.1 50.00 TOTAL ICHTHYOPLANKTON 4
68.2 100.00 65 1,115.4 100.00 26 August Day Night Taxa Life Stage No.
Den.
No.
Den.
Notropis sp.
Juvenile 1
15.4 33.33 3
54.4 37.50 BULLHEAD MINNOW Juvenile 2
36.3 25.00 Pimephales type Yolk-sac 1
18.1 12.50 Pimephales sp.
Juvenile 1
18.1 12.50 CYPRINIDAE sp.
Yolk-sac 2
30.9 66.67 PUMPKINSEED type Post Yolk-sac 1
18.1 12.50 TOTAL ICHTHYOPLANKTON 3
46.3 100.00 8
145.1 100.00 Note: Density (Den.) is No. per million gallons.
DRAFT
Table 18. Depth Comparisons of the Number, Density, and Relative Abundance of Ichthyoplankton Collected during Entrainment Sampling at LaSalle County Station, 3 April - 26 August 2014.
Surface Bottom Taxa Life Stage No.
Den.
No.
Den.
GAR sp.
Post Yolk-sac 2
2.0 0.05 1
1.0 0.03 GIZZARD SHAD Juvenile 5
5.1 0.12 Dorosoma sp.
Yolk-sac 16 16.2 0.39 3
3.1 0.10 Post Yolk-sac 123 124.9 3.01 107 109.4 3.54 COMMON CARP Egg 238 241.7 5.82 193 197.4 6.39 Yolk-sac 565 573.8 13.81 330 337.5 10.92 Post Yolk-sac 1
1.0 0.02 1
1.0 0.03 Juvenile 1
1.0 0.02 Hypophthalmichthys type Egg 18 18.3 0.44 17 17.4 0.56 Notropis sp.
Juvenile 3
3.0 0.07 1
1.0 0.03 BLUNTNOSE MINNOW Post Yolk-sac 1
1.0 0.03 Juvenile 2
2.0 0.05 2
2.0 0.07 BULLHEAD MINNOW Juvenile 2
2.0 0.05 Pimephales type Yolk-sac 341 346.3 8.33 352 360.1 11.65 Post Yolk-sac 4
4.1 0.10 Pimephales sp.
Juvenile 1
1.0 0.03 Semotilus type Yolk-sac 28 28.4 0.68 4
4.1 0.13 Post Yolk-sac 3
3.0 0.07 5
5.1 0.17 CYPRINIDAE sp.
Egg 10 10.2 0.24 12 12.3 0.40 Yolk-sac 845 858.1 20.65 773 790.7 25.58 Post Yolk-sac 10 10.2 0.24 15 15.3 0.50 Moxostoma sp.
Yolk-sac 20 20.3 0.49 8
8.2 0.26 Post Yolk-sac 10 10.2 0.24 9
9.2 0.30 ICTIOBINAE sp.
Yolk-sac 1,180 1,198.4 28.84 570 583.0 18.86 Post Yolk-sac 34 34.5 0.83 18 18.4 0.60 Juvenile 1
1.0 0.02 1
1.0 0.03 CATOSTOMIDAE sp.
Yolk-sac 4
4.1 0.10 CHANNEL CATFISH Juvenile 8
8.1 0.20 8
8.2 0.26 BANDED KILLIFISH Juvenile 1
1.0 0.02 BLACKSTRIPE TOPMINNOW Yolk-sac 1
1.0 0.03 Juvenile 1
1.0 0.02 BROOK SILVERSIDE Yolk-sac 1
1.0 0.02 1
1.0 0.03 Morone sp.
Yolk-sac 3
3.0 0.07 4
4.1 0.13 ROCK BASS Post Yolk-sac 1
1.0 0.02 1
1.0 0.03 GREEN SUNFISH Juvenile 1
1.0 0.03 BLUEGILL type Post Yolk-sac 3
3.0 0.07 PUMPKINSEED type Yolk-sac 20 20.3 0.49 24 24.5 0.79 Post Yolk-sac 6
6.1 0.15 Juvenile 2
2.0 0.07 Lepomis sp.
Yolk-sac 1
1.0 0.02 Post Yolk-sac 8
8.1 0.20 Juvenile 9
9.1 0.22 10 10.2 0.33 LARGEMOUTH BASS Juvenile 1
1.0 0.03 WALLEYE Post Yolk-sac 1
1.0 0.02 Sander sp.
Yolk-sac 24 24.4 0.59 16 16.4 0.53 Post Yolk-sac 1
1.0 0.03 LOGPERCH type Yolk-sac 93 94.4 2.27 73 74.7 2.42 Post Yolk-sac 2
2.0 0.05 DARTER sp.
Yolk-sac 73 74.1 1.78 52 53.2 1.72 Post Yolk-sac 13 13.2 0.32 17 17.4 0.56 Juvenile 2
2.0 0.07 FRESHWATER DRUM Egg 247 250.8 6.04 233 238.3 7.71 Yolk-sac 9
9.1 0.22 6
6.1 0.20 Post Yolk-sac 15 15.2 0.37 5
5.1 0.17 Juvenile 1
1.0 0.03 ROUND GOBY Juvenile 48 48.7 1.17 99 101.3 3.28 Morone /Pomoxis type Egg 8
8.1 0.20 1
1.0 0.03 UNIDENTIFIED Egg 13 13.2 0.32 29 29.7 0.96 Yolk-sac 16 16.2 0.39 10 10.2 0.33 Larvae 2
2.0 0.05 TOTAL ICHTHYOPLANKTON 4,092 4,155.6 100.00 3,022 3,091.1 100.00 Note: Density (Den.) is No. per million gallons.
DRAFT
Table 19. Depth Comparisons of the Number, Density, and Relative Abundance of Ichthyoplankton Collected during Each Entrainment Sampling Event at LaSalle County Station, 3 April - 26 August 2015.
3 April Surface Bottom Taxa Life Stage No.
Den.
No.
Den.
FRESHWATER DRUM Egg 1
16.2 100.00 24 April Surface Bottom Taxa Life Stage No.
Den.
No.
Den.
Dorosoma sp.
Post Yolk-sac 3
49.6 8.57 ICTIOBINAE sp.
Yolk-sac 1
16.5 2.86 Morone sp.
Yolk-sac 2
30 7.69 3
49.6 8.57 Sander sp.
Yolk-sac 14 210.2 53.85 13 214.8 37.14 LOGPERCH type Yolk-sac 8
120.1 30.77 15 247.9 42.86 UNIDENTIFIED Yolk-sac 2
30 7.69 TOTAL ICHTHYOPLANKTON 26 390.3 100.00 35 578.3 100.00 6 May Surface Bottom Taxa Life Stage No.
Den.
No.
Den.
Dorosoma sp.
Yolk-sac 1
16.6 2.94 Post Yolk-sac 5
67.6 9.26 2
33.1 5.88 ICTIOBINAE sp.
Yolk-sac 42 567.9 77.78 27 446.9 79.41 Morone sp.
Yolk-sac 1
13.5 1.85 Sander sp.
Yolk-sac 2
33.1 5.88 LOGPERCH type Yolk-sac 2
27.0 3.70 2
33.1 5.88 UNIDENTIFIED Yolk-sac 4
54.1 7.41 TOTAL ICHTHYOPLANKTON 54 730.1 100.00 34 562.8 100.00 13 May Surface Bottom Taxa Life Stage No.
Den.
No.
Den.
Dorosoma sp.
Post Yolk-sac 8
138.6 0.45 5
79.5 0.58 COMMON CARP Egg 5
86.6 0.28 7
111.3 0.82 Yolk-sac 451 7,812.3 25.54 226 3,593.0 26.34 Semotilus type Yolk-sac 23 398.4 1.30 3
47.7 0.35 CYPRINIDAE sp.
Yolk-sac 79 1,368.5 4.47 66 1,049.3 7.69 Moxostoma sp.
Yolk-sac 8
138.6 0.45 3
47.7 0.35 Post Yolk-sac 2
34.6 0.11 1
15.9 0.12 ICTIOBINAE sp.
Yolk-sac 990 17,148.9 56.06 370 5,882.4 43.12 Post Yolk-sac 19 329.1 1.08 7
111.3 0.82 CATOSTOMIDAE sp.
Yolk-sac 3
52.0 0.17 PUMPKINSEED type Yolk-sac 3
47.7 0.35 WALLEYE Post Yolk-sac 1
17.3 0.06 Sander sp.
Yolk-sac 8
138.6 0.45 1
15.9 0.12 Post Yolk-sac 1
15.9 0.12 LOGPERCH type Yolk-sac 62 1,074.0 3.51 40 635.9 4.66 DARTER sp.
Yolk-sac 31 537.0 1.76 29 461.1 3.38 Post Yolk-sac 2
34.6 0.11 FRESHWATER DRUM Egg 56 970.0 3.17 67 1,065.2 7.81 UNIDENTIFIED Egg 9
155.9 0.51 26 413.4 3.03 Yolk-sac 7
121.3 0.40 3
47.7 0.35 Larvae 2
34.6 0.11 TOTAL ICHTHYOPLANKTON 1,766 30,590.9 100.00 858 13,640.8 100.00 DRAFT
Table 19 (cont.)
20 May Surface Bottom Taxa Life Stage No.
Den.
No.
Den.
COMMON CARP Egg 1
14.2 0.87 1
13.9 1.75 Yolk-sac 1
14.2 0.87 1
13.9 1.75 Post Yolk-sac 1
14.2 0.87 Semotilus type Yolk-sac 5
70.9 4.35 Post Yolk-sac 2
28.4 1.74 5
69.5 8.77 CYPRINIDAE sp.
Yolk-sac 13 184.4 11.30 1
13.9 1.75 Moxostoma sp.
Yolk-sac 12 170.2 10.43 5
69.5 8.77 Post Yolk-sac 2
28.4 1.74 ICTIOBINAE sp.
Yolk-sac 37 524.7 32.17 23 319.7 40.35 Post Yolk-sac 14 198.5 12.17 9
125.1 15.79 LOGPERCH type Yolk-sac 9
127.6 7.83 4
55.6 7.02 DARTER sp.
Yolk-sac 15 212.7 13.04 6
83.4 10.53 Post Yolk-sac 1
13.9 1.75 FRESHWATER DRUM Egg 1
13.9 1.75 Morone /Pomoxis type Egg 3
42.5 2.61 TOTAL ICHTHYOPLANKTON 115 1,630.8 100.00 57 792.3 100.00 28 May Surface Bottom Taxa Life Stage No.
Den.
No.
Den.
Dorosoma sp.
Post Yolk-sac 4
71.0 1.48 13 222.5 3.69 COMMON CARP Yolk-sac 48 851.7 17.78 66 1,129.7 18.75 Post Yolk-sac 1
17.1 0.28 BLUNTNOSE MINNOW Juvenile 2
34.2 0.57 CYPRINIDAE sp.
Egg 10 177.4 3.70 12 205.4 3.41 Yolk-sac 68 1,206.5 25.19 83 1,420.7 23.58 Moxostoma sp.
Post Yolk-sac 2
35.5 0.74 ICTIOBINAE sp.
Yolk-sac 89 1,579.1 32.96 135 2,310.7 38.35 Morone sp.
Yolk-sac 1
17.1 0.28 PUMPKINSEED type Yolk-sac 1
17.7 0.37 1
17.1 0.28 LOGPERCH type Yolk-sac 3
53.2 1.11 4
68.5 1.14 Post Yolk-sac 2
35.5 0.74 DARTER sp.
Yolk-sac 5
88.7 1.85 FRESHWATER DRUM Egg 12 212.9 4.44 14 239.6 3.98 ROUND GOBY Juvenile 21 372.6 7.78 19 325.2 5.40 Morone /Pomoxis type Egg 5
88.7 1.85 1
17.1 0.28 TOTAL ICHTHYOPLANKTON 270 4,790.6 100.00 352 6,025.0 100.00 3 June Surface Bottom Taxa Life Stage No.
Den.
No.
Den.
Dorosoma sp.
Yolk-sac 2
33.3 0.36 Post Yolk-sac 24 427.9 5.19 23 382.4 4.15 COMMON CARP Yolk-sac 4
71.3 0.87 4
66.5 0.72 BLUNTNOSE MINNOW Post Yolk-sac 1
16.6 0.18 Pimephales type Yolk-sac 10 178.3 2.16 41 681.6 7.40 Semotilus type Yolk-sac 1
16.6 0.18 CYPRINIDAE sp.
Yolk-sac 274 4,885.8 59.31 322 5,353.3 58.12 Moxostoma sp.
Post Yolk-sac 1
17.8 0.22 1
16.6 0.18 ICTIOBINAE sp.
Yolk-sac 1
17.8 0.22 Post Yolk-sac 1
16.6 0.18 BLUEGILL type Post Yolk-sac 3
53.5 0.65 PUMPKINSEED type Yolk-sac 1
17.8 0.22 3
49.9 0.54 Lepomis sp.
Post Yolk-sac 1
17.8 0.22 Sander sp.
Yolk-sac 1
17.8 0.22 LOGPERCH type Yolk-sac 1
16.6 0.18 DARTER sp.
Yolk-sac 3
53.5 0.65 6
99.8 1.08 Post Yolk-sac 1
16.6 0.18 FRESHWATER DRUM Egg 136 2,425.0 29.44 113 1,878.7 20.40 Yolk-sac 2
35.7 0.43 1
16.6 0.18 Post Yolk-sac 1
17.8 0.22 ROUND GOBY Juvenile 30 498.8 5.42 UNIDENTIFIED Yolk-sac 3
49.9 0.54 TOTAL ICHTHYOPLANKTON 462 8,238.0 100.00 554 9,210.4 100.00 DRAFT
Table 19 (cont.)
11 June Surface Bottom Taxa Life Stage No.
Den.
No.
Den.
GAR sp.
Post Yolk-sac 1
17.4 0.32 Dorosoma sp.
Post Yolk-sac 18 305.2 5.04 21 366.4 6.69 COMMON CARP Egg 194 3,289.2 54.34 151 2,634.8 48.09 Yolk-sac 13 220.4 3.64 13 226.8 4.14 Pimephales type Yolk-sac 23 390.0 6.44 17 296.6 5.41 Post Yolk-sac 2
33.9 0.56 Semotilus type Post Yolk-sac 1
17.0 0.28 CYPRINIDAE sp.
Yolk-sac 43 729.1 12.04 57 994.6 18.15 Post Yolk-sac 10 169.5 2.80 1
17.4 0.32 Moxostoma sp.
Post Yolk-sac 3
50.9 0.84 3
52.3 0.96 ICTIOBINAE sp.
Post Yolk-sac 1
17.0 0.28 ROCK BASS Post Yolk-sac 1
17.0 0.28 1
17.4 0.32 PUMPKINSEED type Yolk-sac 1
17.0 0.28 3
52.3 0.96 LOGPERCH type Yolk-sac 4
67.8 1.12 2
34.9 0.64 DARTER sp.
Yolk-sac 2
33.9 0.56 1
17.4 0.32 Post Yolk-sac 3
50.9 0.84 7
122.1 2.23 FRESHWATER DRUM Egg 34 576.5 9.52 18 314.1 5.73 ROUND GOBY Juvenile 4
67.8 1.12 17 296.6 5.41 UNIDENTIFIED Yolk-sac 1
17.4 0.32 TOTAL ICHTHYOPLANKTON 357 6,052.8 100.00 314 5,479.0 100.00 17 June Surface Bottom Taxa Life Stage No.
Den.
No.
Den.
Dorosoma sp.
Yolk-sac 15 271.8 3.66 Post Yolk-sac 29 525.5 7.07 24 428.0 5.14 COMMON CARP Egg 21 380.5 5.12 18 321.0 3.85 Yolk-sac 1
18.1 0.24 2
35.7 0.43 Pimephales type Yolk-sac 58 1051.0 14.15 176 3138.8 37.69 CYPRINIDAE sp.
Yolk-sac 241 4367.1 58.78 186 3317.2 39.83 Moxostoma sp.
Post Yolk-sac 4
71.3 0.86 ICTIOBINAE sp.
Yolk-sac 12 217.4 2.93 12 214.0 2.57 GREEN SUNFISH Juvenile 1
17.8 0.21 PUMPKINSEED type Yolk-sac 2
36.2 0.49 5
89.2 1.07 Post Yolk-sac 2
36.2 0.49 Lepomis sp.
Post Yolk-sac 1
18.1 0.24 Sander sp.
Yolk-sac 1
18.1 0.24 LOGPERCH type Yolk-sac 2
36.2 0.49 DARTER sp.
Yolk-sac 11 199.3 2.68 6
107.0 1.28 Post Yolk-sac 5
90.6 1.22 6
107.0 1.28 FRESHWATER DRUM Egg 3
54.4 0.73 13 231.8 2.78 Yolk-sac 1
18.1 0.24 1
17.8 0.21 Post Yolk-sac 5
90.6 1.22 ROUND GOBY Juvenile 12 214.0 2.57 UNIDENTIFIED Yolk-sac 1
17.8 0.21 TOTAL ICHTHYOPLANKTON 410 7429.5 100.00 467 8328.6 100.00 24 June Surface Bottom Taxa Life Stage No.
Den.
No.
Den.
GIZZARD SHAD Juvenile 3
46.5 1.00 Dorosoma sp.
Yolk-sac 1
15.5 0.33 Post Yolk-sac 28 434.5 9.36 11 194.1 9.65 COMMON CARP Egg 8
124.1 2.68 Yolk-sac 41 636.2 13.71 17 299.9 14.91 Hypophthalmichthys type Egg 16 248.3 5.35 14 247.0 12.28 BLUNTNOSE MINNOW Juvenile 2
31.0 0.67 Pimephales type Yolk-sac 109 1,691.3 36.45 27 476.3 23.68 CYPRINIDAE sp.
Yolk-sac 43 667.2 14.38 16 282.3 14.04 ICTIOBINAE sp.
Yolk-sac 6
93.1 2.01 Post Yolk-sac 1
17.6 0.88 Juvenile 1
15.5 0.33 1
17.6 0.88 BLACKSTRIPE TOPMINNOW Yolk-sac 1
17.6 0.88 Juvenile 1
15.5 0.33 DRAFT
Table 19 (cont.)
24 June (cont.)
Surface Bottom Taxa (cont.)
Life Stage No.
Den.
No.
Den.
BROOK SILVERSIDE Yolk-sac 1
15.5 0.33 1
17.6 0.88 PUMPKINSEED type Yolk-sac 7
108.6 2.34 2
35.3 1.75 Post Yolk-sac 1
15.5 0.33 Lepomis sp.
Post Yolk-sac 3
46.5 1.00 LARGEMOUTH BASS Juvenile 1
17.6 0.88 LOGPERCH type Yolk-sac 2
31.0 0.67 2
35.3 1.75 DARTER sp.
Yolk-sac 5
77.6 1.67 4
70.6 3.51 Post Yolk-sac 2
31.0 0.67 2
35.3 1.75 Juvenile 2
35.3 1.75 FRESHWATER DRUM Egg 2
31.0 0.67 1
17.6 0.88 Post Yolk-sac 9
139.6 3.01 5
88.2 4.39 Juvenile 1
17.6 0.88 ROUND GOBY Juvenile 7
108.6 2.34 5
88.2 4.39 UNIDENTIFIED Yolk-sac 1
15.5 0.33 TOTAL ICHTHYOPLANKTON 299 4,639.4 100.00 114 2,011.1 100.00 9 July Surface Bottom Taxa Life Stage No.
Den.
No.
Den.
GAR sp.
Post Yolk-sac 2
30.8 2.63 GIZZARD SHAD Juvenile 1
15.4 1.32 Dorosoma sp.
Post Yolk-sac 3
46.2 3.95 COMMON CARP Egg 3
50.3 7.32 Yolk-sac 1
16.8 2.44 Hypophthalmichthys type Egg 1
15.4 1.32 3
50.3 7.32 Pimephales type Yolk-sac 23 354.5 30.26 9
150.8 21.95 Post Yolk-sac 2
30.8 2.63 CYPRINIDAE sp.
Yolk-sac 19 292.9 25.00 1
16.8 2.44 ICTIOBINAE sp.
Yolk-sac 2
30.8 2.63 2
33.5 4.88 CHANNEL CATFISH Juvenile 3
46.2 3.95 1
16.8 2.44 PUMPKINSEED type Post Yolk-sac 2
30.8 2.63 Juvenile 2
33.5 4.88 Lepomis sp.
Post Yolk-sac 1
15.4 1.32 LOGPERCH type Yolk-sac 1
15.4 1.32 DARTER sp.
Yolk-sac 1
15.4 1.32 FRESHWATER DRUM Egg 2
30.8 2.63 2
33.5 4.88 Yolk-sac 1
16.8 2.44 ROUND GOBY Juvenile 13 200.4 17.11 16 268.0 39.02 TOTAL ICHTHYOPLANKTON 76 1,171.6 100.00 41 686.8 100.00 15 July Surface Bottom Taxa Life Stage No.
Den.
No.
Den.
GIZZARD SHAD Juvenile 1
18.1 0.81 Dorosoma sp.
Post Yolk-sac 2
36.1 1.61 4
61.5 4.00 COMMON CARP Egg 6
108.4 4.84 11 169.1 11.00 Yolk-sac 5
90.4 4.03 Juvenile 1
18.1 0.81 Pimephales type Yolk-sac 56 1,012.0 45.16 37 568.7 37.00 CYPRINIDAE sp.
Yolk-sac 25 451.8 20.16 16 245.9 16.00 CATOSTOMIDAE sp.
Yolk-sac 1
18.1 0.81 CHANNEL CATFISH Juvenile 5
90.4 4.03 7
107.6 7.00 BANDED KILLIFISH Juvenile 1
18.1 0.81 PUMPKINSEED type Yolk-sac 4
72.3 3.23 6
92.2 6.00 Lepomis sp.
Yolk-sac 1
18.1 0.81 Post Yolk-sac 2
36.1 1.61 Juvenile 9
162.6 7.26 10 153.7 10.00 LOGPERCH type Yolk-sac 3
46.1 3.00 DARTER sp.
Post Yolk-sac 1
18.1 0.81 FRESHWATER DRUM Egg 1
18.1 0.81 4
61.5 4.00 Yolk-sac 2
30.7 2.00 ROUND GOBY Juvenile 3
54.2 2.42 TOTAL ICHTHYOPLANKTON 124 2,240.8 100.00 100 1,537.0 100.00 DRAFT
Table 19 (cont.)
22 July Surface Bottom Taxa (cont.)
Life Stage No.
Den.
No.
Den.
Pimephales type Yolk-sac 16 268.9 55.17 14 246.0 70.00 CYPRINIDAE sp.
Yolk-sac 5
84.0 17.24 2
35.1 10.00 FRESHWATER DRUM Yolk-sac 5
84.0 17.24 1
17.6 5.00 UNIDENTIFIED Egg 1
16.8 3.45 3
52.7 15.00 Yolk-sac 2
33.6 6.90 TOTAL ICHTHYOPLANKTON 29 487.4 100.00 20 351.5 100.00 29 July Surface Bottom Taxa Life Stage No.
Den.
No.
Den.
Dorosoma sp.
Post Yolk-sac 2
29.5 3.77 COMMON CARP Egg 3
44.2 5.66 2
27.8 4.35 Yolk-sac 1
14.7 1.89 Pimephales type Yolk-sac 24 353.5 45.28 24 334.0 52.17 CYPRINIDAE sp.
Yolk-sac 16 235.7 30.19 20 278.3 43.48 ICTIOBINAE sp.
Yolk-sac 1
14.7 1.89 PUMPKINSEED type Yolk-sac 3
44.2 5.66 FRESHWATER DRUM Yolk-sac 1
14.7 1.89 UNIDENTIFIED Egg 2
29.5 3.77 TOTAL ICHTHYOPLANKTON 53 780.7 100.00 46 640.2 100.00 12 August Surface Bottom Taxa Life Stage No.
Den.
No.
Den.
Dorosoma sp.
Post Yolk-sac 1
16.9 3.85 Hypophthalmichthys type Egg 1
17.3 2.33 Pimephales type Yolk-sac 21 363.2 48.84 7
118.4 26.92 CYPRINIDAE sp.
Yolk-sac 19 328.6 44.19 1
16.9 3.85 Post Yolk-sac 14 236.7 53.85 PUMPKINSEED type Yolk-sac 1
17.3 2.33 1
16.9 3.85 UNIDENTIFIED Egg 1
17.3 2.33 Yolk-sac 2
33.8 7.69 TOTAL ICHTHYOPLANKTON 43 743.7 100.00 26 439.6 100.00 26 August Surface Bottom Taxa Life Stage No.
Den.
No.
Den.
Notropis sp.
Juvenile 3
52.1 42.86 1
16.1 25.00 BULLHEAD MINNOW Juvenile 2
34.7 28.57 Pimephales type Yolk-sac 1
17.4 14.29 Pimephales sp.
Juvenile 1
16.1 25.00 CYPRINIDAE sp.
Yolk-sac 2
32.1 50.00 PUMPKINSEED type Post Yolk-sac 1
17.4 14.29 TOTAL ICHTHYOPLANKTON 7
121.5 100.00 4
64.2 100.00 Note: Density (Den.) is No. per million gallons.
DRAFT
Common Name Min Length Max Length Mean Length American Eel 692 692 692 Gizzard Shad 47 183 91 Threadfin Shad 51 108 65 Dorosoma Sp.
38 71 53 Central Mudminnow 63 83 74 Grass Pickerel 101 101 101 Goldfish 53 93 70 Common Carp 46 399 109 Hornyhead Chub Golden Shiner 72 98 85 Emerald Shiner 96 96 96 Striped Shiner 72 72 72 Spottail Shiner 73 91 82 Silverband Shiner Spotfin Shiner 38 38 38 Notropis Sp.
Bluntnose Minnow 52 61 57 Fathead Minnow 60 60 60 Bullhead Minnow 56 61 58 Creek Chub Cyprinidae Sp.
White Sucker 67 99 85 Smallmouth Buffalo 71 423 247 Black Redhorse 128 128 128 Golden Redhorse 67 180 124 Oriental Weatherfish 147 179 163 Black Bullhead 48 163 112 Yellow Bullhead 69 69 69 Channel Catfish 56 293 128 Freckled Madtom 63 63 63 Flathead Catfish 68 84 76 Brook Silverside 66 66 66 Yellow Bass 84 143 104 Green Sunfish 39 99 54 Warmouth 95 95 95 Orangespotted Sunfish 50 83 66 Bluegill 36 161 81 Lepomis Sp.
50 50 50 Smallmouth Bass 245 245 245 Largemouth Bass 46 83 67 Black Crappie 45 89 65 Banded Darter Walleye 355 355 355 Sander Sp.
57 57 57 Freshwater Drum 94 167 119 Round Goby 55 97 79
-- Indicates not measured.
Table 20. Total Length (mm) Data for Fish Impinged at LaSalle Station, April 2014 through March 2015.
DRAFT
Table 21. Fish Larvae Length and Fish Egg Diameter (millimeters) Statistics for Ichthyoplankton From Entrainment Samples Collected at LaSalle County Station, 3 April - 26 August 2014.
Minimum Mean Maximum Length/ Length/ Length/
TAXA LIFE STAGE Diameter Diameter Diameter GAR sp. Post Yolk-sac 25.2 25.8 26.1 GIZZARD SHAD Juvenile 18.7 24.2 36.0 Dorosoma sp. Yolk-sac 3.7 6.2 8.6 Dorosoma sp. Post Yolk-sac 4.3 8.6 17.2 COMMON CARP Egg 1.0 1.4 1.9 COMMON CARP Yolk-sac 1.0 6.7 8.8 COMMON CARP Post Yolk-sac 9.3 11.6 13.8 COMMON CARP Juvenile 29.0 29.0 29.0 Hypophthalmichthys type Egg 2.1 3.8 4.8 Notropis sp. Juvenile 11.7 13.9 18.3 BLUNTNOSE MINNOW Post Yolk-sac 16.6 16.6 16.6 BLUNTNOSE MINNOW Juvenile 13.4 18.0 24.1 BULLHEAD MINNOW Juvenile 12.2 18.7 25.1 Pimephales type Yolk-sac 3.8 5.6 7.0 Pimephales type Post Yolk-sac 6.0 8.1 10.4 Pimephales sp. Juvenile 9.8 9.8 9.8 Semotilus type Yolk-sac 6.4 8.5 10.0 Semotilus type Post Yolk-sac 7.9 10.1 12.7 CYPRINIDAE sp. Egg 1.1 1.6 2.0 CYPRINIDAE sp. Yolk-sac 1.2 4.2 8.7 CYPRINIDAE sp. Post Yolk-sac 5.0 7.9 13.6 Moxostoma sp. Yolk-sac 10.7 13.3 14.4 Moxostoma sp. Post Yolk-sac 12.2 14.0 17.0 ICTIOBINAE sp. Yolk-sac 5.7 7.5 10.1 ICTIOBINAE sp. Post Yolk-sac 7.9 10.0 20.2 ICTIOBINAE sp. Juvenile 19.8 22.2 24.5 CATOSTOMIDAE sp. Yolk-sac 3.6 4.8 5.5 CHANNEL CATFISH Juvenile 10.2 14.9 18.7 BANDED KILLIFISH Juvenile 17.5 17.5 17.5 BLACKSTRIPE TOPMINNOW Yolk-sac 6.1 6.1 6.1 BLACKSTRIPE TOPMINNOW Juvenile 10.2 10.2 10.2 BROOK SILVERSIDE Yolk-sac 5.2 5.4 5.6 Morone sp. Yolk-sac 2.7 2.9 3.2 ROCK BASS Post Yolk-sac 7.5 8.9 10.3 GREEN SUNFISH Juvenile 15.2 15.2 15.2 BLUEGILL type Post Yolk-sac 5.3 5.5 5.7 PUMPKINSEED type Yolk-sac 3.7 5.2 6.7 PUMPKINSEED type Post Yolk-sac 7.2 8.5 10.0 PUMPKINSEED type Juvenile 13.8 14.3 14.7 Lepomis sp. Yolk-sac 5.5 5.5 5.5 Lepomis sp. Post Yolk-sac 6.1 9.5 15.6 Lepomis sp. Juvenile 9.6 13.7 18.3 LARGEMOUTH BASS Juvenile 35.5 35.5 35.5 WALLEYE Post Yolk-sac 15.1 15.1 15.1 DRAFT
Table 21 (cont.)
Minimum Mean Maximum Length/ Length/ Length/
TAXA LIFE STAGE Diameter Diameter Diameter Sander sp. Yolk-sac 5.1 8.2 10.3 Sander sp. Post Yolk-sac 10.0 10.0 10.0 LOGPERCH type Yolk-sac 4.0 6.2 9.0 LOGPERCH type Post Yolk-sac 9.8 10.0 10.2 DARTER sp. Yolk-sac 4.9 7.2 10.2 DARTER sp. Post Yolk-sac 6.9 11.1 16.5 DARTER sp. Juvenile 13.1 13.4 13.7 FRESHWATER DRUM Egg 0.8 1.4 2.1 FRESHWATER DRUM Yolk-sac 2.5 4.1 6.6 FRESHWATER DRUM Post Yolk-sac 4.8 8.5 15.8 FRESHWATER DRUM Juvenile 26.1 26.1 26.1 ROUND GOBY Juvenile 6.5 7.9 21.5 Morone/Pomoxis type Egg 0.7 0.9 1.1 UNIDENTIFIED Egg 0.9 1.3 1.8 UNIDENTIFIED Yolk-sac 1.9 4.4 7.1 UNIDENTIFIED Larvae 2.6 2.6 2.6 DRAFT
Table 22. Water Temperatures Recorded during Entrainment Sampling Events, LaSalle County Station, April through August 2014.
Intake Temperature (F)
Period Minimum Mean Maximum 3 April 47.5 47.6 47.7 24 April 59.7 60.1 60.6 6 May 59.7 60.2 60.8 13 May 67.3 67.6 68.0 20 May 61.9 62.2 62.6 28 May 74.8 75.1 75.2 3 June 77.2 77.5 77.9 11 June 71.4 71.7 72.1 17 June 77.2 77.5 77.9 24 June 76.6 77.0 77.5 9 July 79.0 79.5 80.1 15 July 74.3 74.8 75.2 22 July 82.4 82.8 83.3 29 July 78.8 79.4 80.4 12 August 80.4 80.6 80.8 26 August 80.6 80.8 81.1 DRAFT
Table 23. Summary of Water Temperature, Dissolved Oxygen, and Current Velocity Measurements during Entrainment Sampling at LaSalle County Station, 3 April - 26 August 2014.
Surface Bottom Water Dissolved Current Water Dissolved Current Sampling Diel Temperature Oxygen Velocity Temperature Oxygen Velocity Date Period (F)
(mg/L)
(ft/sec)
(F)
(mg/L)
(ft/sec) 3 April Day 47.5 11.4 1.5 47.5 11.4 1.3 Night 47.5 11.2 1.5 47.7 11.2 1.3 24 April Day 60.6 14.0 1.6 60.4 12.9 1.5 Night 59.7 11.5 1.6 59.7 11.2 1.3 6 May Day 60.8 13.6 0.9 60.6 13.6 1.5 Night 59.7 10.2 1.2 59.7 10.2 1.5 13 May Day 68.0 8.2 1.4 67.8 8.2 1.3 Night 67.5 8.1 1.4 67.3 8.1 1.5 20 May Day 62.6 10.4 1.0 62.4 9.8 1.3 Night 62.1 9.5 1.3 61.9 10.0 1.4 28 May Day 75.2 8.5 1.7 75.2 8.5 1.5 Night 74.8 7.7 1.7 75.0 7.8 1.5 3 June Day 77.9 9.7 1.3 77.9 9.7 1.7 Night 77.2 8.5 1.8 77.2 8.4 1.7 11 June Day 72.1 7.7 1.0 71.8 7.8 1.5 Night 71.4 7.4 1.0 71.4 7.3 1.6 17 June Day 77.9 9.5 1.0 77.5 9.5 1.5 Night 77.2 8.3 1.0 77.2 8.4 1.5 24 June Day 77.5 8.2 1.3 77.2 8.2 1.5 Night 76.6 6.8 1.5 76.6 6.8 1.5 9 July Day 80.1 9.0 1.1 80.1 8.9 1.4 Night 79.0 8.1 0.9 79.0 8.0 1.5 15 July Day 75.2 7.6 1.6 75.0 7.6 1.6 Night 74.5 7.3 1.4 74.3 7.3 1.4 22 July Day 83.3 10.5 1.6 82.9 10.4 1.6 Night 82.6 9.4 1.6 82.4 9.1 1.6 29 July Day 80.4 11.0 1.2 79.5 10.6 1.5 Night 79.0 9.6 1.6 78.8 9.4 1.6 12 August Day 80.8 7.6 1.6 80.8 7.9 1.7 Night 80.4 7.3 1.5 80.4 7.3 1.6 26 August Day 81.1 7.1 1.3 80.8 6.9 1.6 Night 80.6 7.0 1.2 80.6 7.0 1.4 Combined Day Min.
47.5 7.1 0.9 47.5 6.9 1.3 Mean 72.6 9.6 1.3 72.3 9.5 1.5 Max.
83.3 14.0 1.7 82.9 13.6 1.7 Combined Night Min.
47.5 6.8 0.9 47.7 6.8 1.3 Mean 71.9 8.6 1.4 71.8 8.6 1.5 Max.
82.6 11.5 1.8 82.4 11.2 1.7 DRAFT
APPENDIX A Raw impingement data listing for impingement at LaSalle County Station by sampling date, April 2014-March 2015 DRAFT
APPENDIX A - RAW IMPINGEMENT DATA LISTING START DATE AND TIME:
4/2/14 13:30 END DATE AND TIME:
4/3/14 13:30 SAMPLING DURATIONS (hrs):
24.00 CW VOLUME SAMPLED (gals x 10^6):
86.4 SAMPLING PERIOD:
02-03 Apr MINIMUM= 9.0 MEAN= 9.4 MAXIMUM= 9.8 INTAKE TEMPERATURES (C):
EXTRAPOLATION PERIOD:
01-12 Apr CW EXTRAPOLATION VOLUME (gals x 10^6):
1,037 SPECIES LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 183 49 GIZZARD SHAD 86 11 BLUEGILL 114 27 BLUEGILL 132 46 BLUEGILL 76 5
SPOTTAIL SHINER 79 5
SPOTTAIL SHINER 38 1
SPOTFIN SHINER 49 2
NORTHERN CLEARWATER CRAYFISH START DATE AND TIME:
4/14/14 13:20 END DATE AND TIME:
4/15/14 13:20 SAMPLING DURATIONS (hrs):
24.00 CW VOLUME SAMPLED (gals x 10^6):
86.4 SAMPLING PERIOD:
14-15 Apr MINIMUM= 12.4 MEAN= 13.9 MAXIMUM= 14.7 INTAKE TEMPERATURES (C):
EXTRAPOLATION PERIOD:
13-26 Apr CW EXTRAPOLATION VOLUME (gals x 10^6):
1,210 SPECIES LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 78 7
ROUND GOBY 77 6
ROUND GOBY 67 5
ROUND GOBY 75 6
ROUND GOBY 72 5
ROUND GOBY 67 4
ROUND GOBY 86 8
ROUND GOBY 93 11 ROUND GOBY 90 10 ROUND GOBY 78 7
ROUND GOBY 63 4
ROUND GOBY 69 5
ROUND GOBY 81 8
ROUND GOBY 71 5
ROUND GOBY 82 6
ROUND GOBY 64 4
ROUND GOBY 83 7
ROUND GOBY 78 6
ROUND GOBY 77 7
ROUND GOBY 76 7
ROUND GOBY 82 7
ROUND GOBY 86 9
ROUND GOBY 87 9
ROUND GOBY 78 7
ROUND GOBY 77 7
ROUND GOBY 77 7
ROUND GOBY 84 8
ROUND GOBY 72 5
ROUND GOBY 80 7
ROUND GOBY 77 6
ROUND GOBY 11 58 ROUND GOBY 140 17 CHANNEL CATFISH 52 2
BLUEGILL 47 2
BLUEGILL 81 10 ORANGESPOTTED SUNFISH 99 7
GIZZARD SHAD A-1 DRAFT
355 382 WALLEYE START DATE AND TIME:
4/30/14 14:08 END DATE AND TIME:
5/1/14 14:01 SAMPLING DURATIONS (hrs):
23.88 CW VOLUME SAMPLED (gals x 10^6):
86.0 SAMPLING PERIOD:
30 Apr-01 MINIMUM= 14.3 MEAN= 14.7 MAXIMUM= 15.1 INTAKE TEMPERATURES (C):
EXTRAPOLATION PERIOD:
27 Apr-10 CW EXTRAPOLATION VOLUME (gals x 10^6):
1,210 SPECIES LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 83 8
ROUND GOBY START DATE AND TIME:
5/12/14 13:40 END DATE AND TIME:
5/13/14 13:42 SAMPLING DURATIONS (hrs):
24.03 CW VOLUME SAMPLED (gals x 10^6):
86.5 SAMPLING PERIOD:
12-13 Ma MINIMUM= 19.8 MEAN= 20.8 MAXIMUM= 21.5 INTAKE TEMPERATURES (C):
EXTRAPOLATION PERIOD:
11-24 Ma CW EXTRAPOLATION VOLUME (gals x 10^6):
1,210 SPECIES LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 80 7
WHITE SUCKER 92 9
WHITE SUCKER 86 8
WHITE SUCKER 67 3
WHITE SUCKER 99 11 WHITE SUCKER 68 3
FLATHEAD CATFISH 71 6
BLUEGILL 87 11 BLUEGILL 96 15 BLUEGILL 67 5
BLUEGILL 55 3
BLUEGILL 91 7
SPOTTAIL SHINER 81 6
SPOTTAIL SHINER 89 7
SPOTTAIL SHINER 73 5
SPOTTAIL SHINER 91 12 ROUND GOBY 90 11 ROUND GOBY 83 8
ROUND GOBY 91 12 ROUND GOBY 88 10 ROUND GOBY 88 11 ROUND GOBY 78 6
ROUND GOBY 81 7
ROUND GOBY 70 5
ROUND GOBY 92 11 ROUND GOBY 90 12 ROUND GOBY 73 6
ROUND GOBY 82 8
ROUND GOBY 85 11 ROUND GOBY 91 10 ROUND GOBY 63 3
ROUND GOBY 68 6
ROUND GOBY 70 5
ROUND GOBY 84 9
ROUND GOBY 83 8
ROUND GOBY 76 6
ROUND GOBY 71 6
ROUND GOBY 69 4
ROUND GOBY 83 12 ORANGESPOTTED SUNFISH 56 3
ORANGESPOTTED SUNFISH 1
3 BLUNTNOSE MINNOW 5
17 CREEK CHUB 245 204 SMALLMOUTH BASS A-2 DRAFT
167 45 FRESHWATER DRUM 153 40 FRESHWATER DRUM 118 14 FRESHWATER DRUM 147 30 FRESHWATER DRUM 135 23 FRESHWATER DRUM 137 23 FRESHWATER DRUM 134 24 FRESHWATER DRUM 145 33 FRESHWATER DRUM 140 25 FRESHWATER DRUM 179 46 ORIENTAL WEATHERFISH 29 83 BLUNTNOSE MINNOW 1
3 EMERALD SHINER 69 5
YELLOW BULLHEAD 62 4
BLACK BULLHEAD 180 83 GOLDEN REDHORSE 1
6 FATHEAD MINNOW 1
28 STRIPED SHINER 1
89 HORNYHEAD CHUB 48 2
BLACK BULLHEAD 1
1 BANDED DARTER 1
1 CYPRINIDAE SP.
START DATE AND TIME:
5/27/14 13:35 END DATE AND TIME:
5/28/14 13:37 SAMPLING DURATIONS (hrs):
24.03 CW VOLUME SAMPLED (gals x 10^6):
86.5 SAMPLING PERIOD:
27-28 Ma MINIMUM= 22.7 MEAN= 23.8 MAXIMUM= 24.5 INTAKE TEMPERATURES (C):
EXTRAPOLATION PERIOD:
25 May-0 CW EXTRAPOLATION VOLUME (gals x 10^6):
1,210 SPECIES LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 97 10 ROUND GOBY 96 7
EMERALD SHINER 1
4 EMERALD SHINER 61 2
BLUNTNOSE MINNOW 72 4
STRIPED SHINER 84 6
FLATHEAD CATFISH 56 2
BLACK BULLHEAD START DATE AND TIME:
6/10/14 13:45 END DATE AND TIME:
6/11/14 13:45 SAMPLING DURATIONS (hrs):
24.00 CW VOLUME SAMPLED (gals x 10^6):
86.4 SAMPLING PERIOD:
10-11 Jun MINIMUM= 21.6 MEAN= 23.1 MAXIMUM= 24.6 INTAKE TEMPERATURES (C):
EXTRAPOLATION PERIOD:
08-21 Jun CW EXTRAPOLATION VOLUME (gals x 10^6):
1,210 SPECIES LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 692 746 AMERICAN EEL 8
28 BULLHEAD MINNOW 1
5 SPOTFIN SHINER 50 2
ORANGESPOTTED SUNFISH 100 8
CHANNEL CATFISH 179 34 CHANNEL CATFISH 1
3 SILVERBAND SHINER START DATE AND TIME:
6/24/14 15:15 END DATE AND TIME:
6/25/14 15:15 SAMPLING DURATIONS (hrs):
24.00 CW VOLUME SAMPLED (gals x 10^6):
86.4 SAMPLING PERIOD:
24-25 Jun MINIMUM= 24.5 MEAN= 25.2 MAXIMUM= 26.0 INTAKE TEMPERATURES (C):
EXTRAPOLATION PERIOD:
22 Jun-05 CW EXTRAPOLATION VOLUME (gals x 10^6):
1,210 SPECIES LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 116 14 CHANNEL CATFISH 134 18 CHANNEL CATFISH 99 22 GREEN SUNFISH 147 17 ORIENTAL WEATHERFISH A-3 DRAFT
78 7
ROUND GOBY 55 2
ROUND GOBY 101 8
GRASS PICKEREL 57 1
SANDER SP.
2 7
BULLHEAD MINNOW 65 3
THREADFIN SHAD 66 2
THREADFIN SHAD 63 2
THREADFIN SHAD 67 3
THREADFIN SHAD 58 2
THREADFIN SHAD 60 2
THREADFIN SHAD 59 2
THREADFIN SHAD 60 3
THREADFIN SHAD 53 1
THREADFIN SHAD 62 2
THREADFIN SHAD 46 1
LARGEMOUTH BASS 65 3
THREADFIN SHAD 63 3
THREADFIN SHAD 1
3 SPOTFIN SHINER 57 3
COMMON CARP 46 2
COMMON CARP START DATE AND TIME:
7/7/14 13:35 END DATE AND TIME:
7/8/14 13:26 SAMPLING DURATIONS (hrs):
23.85 CW VOLUME SAMPLED (gals x 10^6):
85.9 SAMPLING PERIOD:
07-08 Jul MINIMUM= 24.6 MEAN= 25.7 MAXIMUM= 26.6 INTAKE TEMPERATURES (C):
EXTRAPOLATION PERIOD:
06-19 Jul CW EXTRAPOLATION VOLUME (gals x 10^6):
1,210 SPECIES LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 76 8
ROUND GOBY 68 3
THREADFIN SHAD 68 2
THREADFIN SHAD 63 3
THREADFIN SHAD 59 2
GIZZARD SHAD 59 2
GIZZARD SHAD 61 2
GIZZARD SHAD 73 3
GIZZARD SHAD 63 2
GIZZARD SHAD 61 4
BLUEGILL 54 3
COMMON CARP 57 3
COMMON CARP 47 2
COMMON CARP 47 1
COMMON CARP 46 2
COMMON CARP 53 2
COMMON CARP 58 3
COMMON CARP 49 1
BLACK CRAPPIE 49 2
BLACK CRAPPIE 51 2
BLACK CRAPPIE 45 1
BLACK CRAPPIE 58 3
LARGEMOUTH BASS 57 3
LARGEMOUTH BASS 50 2
LEPOMIS SP.
1 PROCAMBARUS SP.
A-4 DRAFT
START DATE AND TIME:
7/28/14 13:45 END DATE AND TIME:
7/29/14 13:40 SAMPLING DURATIONS (hrs):
23.92 CW VOLUME SAMPLED (gals x 10^6):
86.1 SAMPLING PERIOD:
28-29 Jul MINIMUM= 26.2 MEAN= 26.9 MAXIMUM= 27.3 INTAKE TEMPERATURES (C):
EXTRAPOLATION PERIOD:
20 Jul-02 CW EXTRAPOLATION VOLUME (gals x 10^6):
1,210 SPECIES LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 399 580 COMMON CARP 285 170 COMMON CARP 85 8
ROUND GOBY 64 3
GIZZARD SHAD 47 1
GIZZARD SHAD 56 2
GIZZARD SHAD 53 1
GIZZARD SHAD 51 1
GIZZARD SHAD 52 1
GIZZARD SHAD 51 2
GIZZARD SHAD 49 1
GIZZARD SHAD 56 2
GIZZARD SHAD 55 2
GIZZARD SHAD 63 3
GIZZARD SHAD 52 1
GIZZARD SHAD 51 2
GIZZARD SHAD 53 2
GIZZARD SHAD 74 4
GIZZARD SHAD 57 2
GIZZARD SHAD 50 2
GIZZARD SHAD 50 2
GIZZARD SHAD 55 2
GIZZARD SHAD 55 2
GIZZARD SHAD 49 1
GIZZARD SHAD 51 1
GIZZARD SHAD 49 1
GIZZARD SHAD 53 2
GIZZARD SHAD 53 2
GIZZARD SHAD 47 1
GIZZARD SHAD 57 1
GIZZARD SHAD 50 1
GIZZARD SHAD 2
2 GIZZARD SHAD START DATE AND TIME:
8/11/14 13:45 END DATE AND TIME:
8/12/14 13:45 SAMPLING DURATIONS (hrs):
24.00 CW VOLUME SAMPLED (gals x 10^6):
86.4 SAMPLING PERIOD:
11-12 Aug MINIMUM= 27.2 MEAN= 27.6 MAXIMUM= 28.0 INTAKE TEMPERATURES (C):
EXTRAPOLATION PERIOD:
03-16 Aug CW EXTRAPOLATION VOLUME (gals x 10^6):
1,210 SPECIES LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 53 1
THREADFIN SHAD 62 2
THREADFIN SHAD 51 1
THREADFIN SHAD 53 1
THREADFIN SHAD 52 1
THREADFIN SHAD 41 1
GREEN SUNFISH 1
3 BLUNTNOSE MINNOW 1
1 DOROSOMA SP.
51 1
BLUEGILL 38 1
BLUEGILL 1
1 PINK HEELSPLITTER A-5 DRAFT
START DATE AND TIME:
8/25/14 13:30 END DATE AND TIME:
8/26/14 13:36 SAMPLING DURATIONS (hrs):
24.10 CW VOLUME SAMPLED (gals x 10^6):
86.8 SAMPLING PERIOD:
25-26 Aug MINIMUM= 25.7 MEAN= 26.8 MAXIMUM= 27.6 INTAKE TEMPERATURES (C):
EXTRAPOLATION PERIOD:
17-30 Aug CW EXTRAPOLATION VOLUME (gals x 10^6):
1,210 SPECIES LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 293 212 CHANNEL CATFISH 65 2
THREADFIN SHAD 53 1
THREADFIN SHAD 62 3
THREADFIN SHAD 57 2
THREADFIN SHAD 57 2
GIZZARD SHAD 74 4
GIZZARD SHAD 68 3
GIZZARD SHAD 103 9
GIZZARD SHAD 106 10 GIZZARD SHAD 66 2
GIZZARD SHAD 62 3
GIZZARD SHAD 41 1
DOROSOMA SP.
62 2
DOROSOMA SP.
53 1
DOROSOMA SP.
54 1
DOROSOMA SP.
61 2
DOROSOMA SP.
52 2
DOROSOMA SP.
71 2
DOROSOMA SP.
65 4
ROUND GOBY 44 1
BLUEGILL 36 1
BLUEGILL 67 4
GOLDEN REDHORSE 1
1 NOTROPIS SP.
143 49 YELLOW BASS START DATE AND TIME:
9/7/14 13:15 END DATE AND TIME:
9/8/14 13:30 SAMPLING DURATIONS (hrs):
24.25 CW VOLUME SAMPLED (gals x 10^6):
87.3 SAMPLING PERIOD:
07-08 Sep MINIMUM= 25.8 MEAN= 26.3 MAXIMUM= 26.7 INTAKE TEMPERATURES (C):
EXTRAPOLATION PERIOD:
31 Aug-13 CW EXTRAPOLATION VOLUME (gals x 10^6):
1,210 SPECIES LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 85 7
YELLOW BASS 98 8
GOLDEN SHINER 117 10 CHANNEL CATFISH 72 4
CHANNEL CATFISH 105 16 FRESHWATER DRUM 50 2
BLUEGILL 52 1
BLUNTNOSE MINNOW 94 8
THREADFIN SHAD 63 2
THREADFIN SHAD 88 5
THREADFIN SHAD 61 2
THREADFIN SHAD 58 2
THREADFIN SHAD 55 2
THREADFIN SHAD 83 4
THREADFIN SHAD 57 2
THREADFIN SHAD 56 1
THREADFIN SHAD 65 2
THREADFIN SHAD 58 2
THREADFIN SHAD 54 1
THREADFIN SHAD 63 2
THREADFIN SHAD 57 2
THREADFIN SHAD A-6 DRAFT
90 6
GIZZARD SHAD 65 3
GIZZARD SHAD 66 3
GIZZARD SHAD 70 3
GIZZARD SHAD 48 1
DOROSOMA SP.
38 1
DOROSOMA SP.
46 1
DOROSOMA SP.
52 1
DOROSOMA SP.
3 6
PAPER PONDSHELL START DATE AND TIME:
9/22/14 14:00 END DATE AND TIME:
9/23/14 14:45 SAMPLING DURATIONS (hrs):
24.75 CW VOLUME SAMPLED (gals x 10^6):
89.1 SAMPLING PERIOD:
22-23 Sep MINIMUM= 20.1 MEAN= 20.6 MAXIMUM= 21.0 INTAKE TEMPERATURES (C):
EXTRAPOLATION PERIOD:
14 Sep-25 CW EXTRAPOLATION VOLUME (gals x 10^6):
1,987 SPECIES LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 95 7
GIZZARD SHAD 97 8
GIZZARD SHAD 59 2
GIZZARD SHAD 56 1
GIZZARD SHAD 57 2
GIZZARD SHAD 103 9
THREADFIN SHAD 73 4
THREADFIN SHAD 67 3
THREADFIN SHAD 78 4
THREADFIN SHAD 56 2
THREADFIN SHAD 63 2
THREADFIN SHAD 74 4
THREADFIN SHAD 61 2
THREADFIN SHAD 72 3
THREADFIN SHAD 74 4
THREADFIN SHAD 73 4
THREADFIN SHAD 71 3
THREADFIN SHAD 63 2
THREADFIN SHAD 59 2
THREADFIN SHAD 60 2
THREADFIN SHAD 62 3
THREADFIN SHAD 65 3
THREADFIN SHAD 56 1
CHANNEL CATFISH 61 4
BLUEGILL 1
5 CREEK CHUB 74 4
THREADFIN SHAD 1
1 PAPER PONDSHELL 2
3 FRAGILE PAPERSHELL START DATE AND TIME:
11/24/14 13:30 END DATE AND TIME:
11/25/14 13:33 SAMPLING DURATIONS (hrs):
24.05 CW VOLUME SAMPLED (gals x 10^6):
86.6 SAMPLING PERIOD:
24-25 Nov MINIMUM= 4.4 MEAN= 5.6 MAXIMUM= 7.3 INTAKE TEMPERATURES (C):
EXTRAPOLATION PERIOD:
26 Oct-06 CW EXTRAPOLATION VOLUME (gals x 10^6):
1,598 SPECIES LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 423 1260 SMALLMOUTH BUFFALO 95 29 WARMOUTH 154 49 FRESHWATER DRUM 94 9
FRESHWATER DRUM 119 17 FRESHWATER DRUM 113 13 FRESHWATER DRUM 112 14 FRESHWATER DRUM 101 10 FRESHWATER DRUM A-7 DRAFT
107 13 FRESHWATER DRUM 120 20 FRESHWATER DRUM 110 13 FRESHWATER DRUM 110 16 FRESHWATER DRUM 97 11 FRESHWATER DRUM 109 12 FRESHWATER DRUM 133 24 FRESHWATER DRUM 106 11 FRESHWATER DRUM 122 13 GIZZARD SHAD 1
6 GIZZARD SHAD 77 7
LARGEMOUTH BASS 71 6
LARGEMOUTH BASS 148 65 BLUEGILL 147 66 BLUEGILL 115 32 BLUEGILL 43 1
BLUEGILL 44 2
BLUEGILL 43 2
BLUEGILL 88 12 BLUEGILL 56 4
BLUEGILL 108 12 THREADFIN SHAD 1
8 THREADFIN SHAD 92 14 GOLDFISH 75 8
GOLDFISH 55 3
GOLDFISH 86 10 GOLDFISH 70 6
GOLDFISH 145 47 BLACK BULLHEAD 163 76 BLACK BULLHEAD 137 37 BLACK BULLHEAD 143 48 BLACK BULLHEAD 67 7
GREEN SUNFISH 70 7
GREEN SUNFISH 63 6
GREEN SUNFISH 66 7
GREEN SUNFISH 50 3
GREEN SUNFISH 51 3
GREEN SUNFISH 39 1
GREEN SUNFISH 48 2
GREEN SUNFISH 55 4
GREEN SUNFISH 50 3
GREEN SUNFISH 43 2
GREEN SUNFISH 47 2
GREEN SUNFISH 47 2
GREEN SUNFISH 46 2
GREEN SUNFISH 89 9
BLACK CRAPPIE 76 6
BLACK CRAPPIE 56 2
BULLHEAD MINNOW 61 3
BULLHEAD MINNOW 56 2
BULLHEAD MINNOW 63 3
FRECKLED MADTOM 40 2
NORTHERN CLEARWATER CRAYFISH 2
6 PAPER PONDSHELL A-8 DRAFT
START DATE AND TIME:
12/15/14 13:35 END DATE AND TIME:
12/16/14 13:47 SAMPLING DURATIONS (hrs):
24.20 CW VOLUME SAMPLED (gals x 10^6):
87.1 SAMPLING PERIOD:
15-16 Dec MINIMUM= 6.0 MEAN= 6.5 MAXIMUM= 6.8 INTAKE TEMPERATURES (C):
EXTRAPOLATION PERIOD:
07-20 Dec CW EXTRAPOLATION VOLUME (gals x 10^6):
1,210 SPECIES LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 111 13 FRESHWATER DRUM 112 14 FRESHWATER DRUM 105 11 FRESHWATER DRUM 117 16 FRESHWATER DRUM 102 9
GIZZARD SHAD 92 7
GIZZARD SHAD 89 6
GIZZARD SHAD 118 14 GIZZARD SHAD 117 14 GIZZARD SHAD 100 9
GIZZARD SHAD 93 8
GIZZARD SHAD 104 8
GIZZARD SHAD 113 13 GIZZARD SHAD 118 14 GIZZARD SHAD 103 9
GIZZARD SHAD 77 6
LARGEMOUTH BASS 101 21 BLUEGILL 1
6 SPOTTAIL SHINER 39 2
NORTHERN CLEARWATER CRAYFISH START DATE AND TIME:
12/22/14 13:35 END DATE AND TIME:
12/23/14 13:35 SAMPLING DURATIONS (hrs):
24.00 CW VOLUME SAMPLED (gals x 10^6):
86.4 SAMPLING PERIOD:
22-23 Dec MINIMUM= 4.9 MEAN= 5.6 MAXIMUM= 6.8 INTAKE TEMPERATURES (C):
EXTRAPOLATION PERIOD:
21 Dec-10 CW EXTRAPOLATION VOLUME (gals x 10^6):
1,642 SPECIES LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 93 8
GIZZARD SHAD 89 7
GIZZARD SHAD 96 8
GIZZARD SHAD 98 8
GIZZARD SHAD 156 31 GIZZARD SHAD 91 8
GIZZARD SHAD 97 9
GIZZARD SHAD 112 12 GIZZARD SHAD 104 10 GIZZARD SHAD 106 11 GIZZARD SHAD 104 10 GIZZARD SHAD 101 9
GIZZARD SHAD 99 9
GIZZARD SHAD 97 8
GIZZARD SHAD 99 10 GIZZARD SHAD 104 10 GIZZARD SHAD 115 13 GIZZARD SHAD 113 13 GIZZARD SHAD 110 12 GIZZARD SHAD 94 7
GIZZARD SHAD 116 15 GIZZARD SHAD 132 19 GIZZARD SHAD 115 14 GIZZARD SHAD 87 5
GIZZARD SHAD 72 3
GIZZARD SHAD 107 10 GIZZARD SHAD 101 8
GIZZARD SHAD A-9 DRAFT
89 6
GIZZARD SHAD 97 8
GIZZARD SHAD 102 10 GIZZARD SHAD 48 475 GIZZARD SHAD 122 17 FRESHWATER DRUM 98 10 FRESHWATER DRUM 106 10 FRESHWATER DRUM 120 16 FRESHWATER DRUM 132 20 FRESHWATER DRUM 117 15 FRESHWATER DRUM 60 4
BLUEGILL 53 2
BLUEGILL 46 2
BLUEGILL 4
11 DOROSOMA SP.
84 7
YELLOW BASS 70 8
NORTHERN CLEARWATER CRAYFISH START DATE AND TIME:
1/26/15 13:40 END DATE AND TIME:
1/27/15 13:31 SAMPLING DURATIONS (hrs):
23.85 CW VOLUME SAMPLED (gals x 10^6):
85.9 SAMPLING PERIOD:
26-27 Jan MINIMUM= 1.6 MEAN= 1.8 MAXIMUM= 2.2 INTAKE TEMPERATURES (C):
EXTRAPOLATION PERIOD:
11-31 Jan CW EXTRAPOLATION VOLUME (gals x 10^6):
1,728 SPECIES LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 83 8
LARGEMOUTH BASS 86 11 GOLDFISH 67 5
GOLDFISH 66 5
GOLDFISH 67 4
GOLDFISH 58 3
GOLDFISH 67 5
GOLDFISH 66 5
GOLDFISH 66 5
GOLDFISH 54 3
GOLDFISH 62 3
GOLDFISH 56 3
GOLDFISH 77 7
BLUEGILL 62 4
BLUEGILL 71 6
BLUEGILL 3
11 SPOTFIN SHINER 46 2
GREEN SUNFISH 61 4
ORANGESPOTTED SUNFISH 128 23 BLACK REDHORSE 2
12 GIZZARD SHAD 147 26 GIZZARD SHAD 136 22 GIZZARD SHAD 104 10 GIZZARD SHAD 114 15 GIZZARD SHAD 127 21 GIZZARD SHAD 124 20 GIZZARD SHAD 146 28 GIZZARD SHAD 113 14 GIZZARD SHAD 106 12 GIZZARD SHAD 113 10 GIZZARD SHAD 92 7
GIZZARD SHAD 104 11 GIZZARD SHAD 132 21 GIZZARD SHAD 126 18 GIZZARD SHAD 108 11 GIZZARD SHAD A-10 DRAFT
102 9
GIZZARD SHAD 91 7
GIZZARD SHAD 107 11 GIZZARD SHAD 131 20 GIZZARD SHAD 96 9
GIZZARD SHAD 118 14 GIZZARD SHAD 103 5
GIZZARD SHAD 112 12 GIZZARD SHAD 99 9
GIZZARD SHAD 97 8
GIZZARD SHAD 105 9
GIZZARD SHAD 113 12 GIZZARD SHAD 116 14 GIZZARD SHAD 113 12 GIZZARD SHAD 116 15 GIZZARD SHAD 95 9
GIZZARD SHAD 46 2
GREEN SUNFISH 1
5 THREADFIN SHAD START DATE AND TIME:
2/9/15 13:30 END DATE AND TIME:
2/10/15 13:36 SAMPLING DURATIONS (hrs):
24.10 CW VOLUME SAMPLED (gals x 10^6):
86.8 SAMPLING PERIOD:
09-10 Feb MINIMUM= 3.3 MEAN= 3.7 MAXIMUM= 4.0 INTAKE TEMPERATURES (C):
EXTRAPOLATION PERIOD:
01-25 Feb CW EXTRAPOLATION VOLUME (gals x 10^6):
1,814 SPECIES LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 155 87 BLUEGILL 131 43 BLUEGILL 110 26 BLUEGILL 161 88 BLUEGILL 104 13 FRESHWATER DRUM 124 18 FRESHWATER DRUM 122 16 FRESHWATER DRUM 159 61 COMMON CARP 5
27 SPOTTAIL SHINER 76 5
BLACK CRAPPIE 79 6
BLACK CRAPPIE 74 5
BLACK CRAPPIE 97 9
GIZZARD SHAD 110 13 GIZZARD SHAD 119 15 GIZZARD SHAD 100 8
GIZZARD SHAD 56 3
GOLDFISH 84 10 GOLDFISH 69 5
GOLDFISH 74 6
GOLDFISH 58 3
GOLDFISH 60 3
GOLDFISH START DATE AND TIME:
3/16/15 13:30 END DATE AND TIME:
3/17/15 13:32 SAMPLING DURATIONS (hrs):
24.03 CW VOLUME SAMPLED (gals x 10^6):
86.5 SAMPLING PERIOD:
16-17 Ma MINIMUM= 8.1 MEAN= 9.1 MAXIMUM= 9.9 INTAKE TEMPERATURES (C):
EXTRAPOLATION PERIOD:
26 Feb-21 CW EXTRAPOLATION VOLUME (gals x 10^6):
1,728 SPECIES LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 138 50 BLUEGILL 140 53 BLUEGILL 64 4
BLUEGILL 57 3
BLUEGILL 50 2
BLUEGILL A-11 DRAFT
86 11 GOLDFISH 93 12 GOLDFISH 93 12 GOLDFISH 73 5
GOLDFISH 56 2
GOLDFISH 53 2
GOLDFISH 71 4
CENTRAL MUDMINNOW 83 7
CENTRAL MUDMINNOW 83 6
CENTRAL MUDMINNOW 71 4
CENTRAL MUDMINNOW 77 6
CENTRAL MUDMINNOW 73 4
CENTRAL MUDMINNOW 72 4
CENTRAL MUDMINNOW 73 5
CENTRAL MUDMINNOW 1
6 GOLDFISH 73 2
CHANNEL CATFISH 128 16 GIZZARD SHAD 122 21 BLACK BULLHEAD 134 36 BLACK BULLHEAD 52 3
GREEN SUNFISH 49 2
GREEN SUNFISH 1
2 EMERALD SHINER 3
21 NORTHERN CLEARWATER CRAYFISH START DATE AND TIME:
3/30/15 13:30 END DATE AND TIME:
3/31/15 13:28 SAMPLING DURATIONS (hrs):
23.97 CW VOLUME SAMPLED (gals x 10^6):
86.3 SAMPLING PERIOD:
30-31 Ma MINIMUM= 7.2 MEAN= 8.2 MAXIMUM= 9.2 INTAKE TEMPERATURES (C):
EXTRAPOLATION PERIOD:
22-31 Ma CW EXTRAPOLATION VOLUME (gals x 10^6):
864 SPECIES LENGTH WEIGHT PLUS COUNT BATCH WEIGHT 73 6
CENTRAL MUDMINNOW 63 4
CENTRAL MUDMINNOW 60 3
FATHEAD MINNOW 66 2
BROOK SILVERSIDE 94 8
FRESHWATER DRUM 107 10 FRESHWATER DRUM 96 5
FRESHWATER DRUM 98 7
GIZZARD SHAD 100 8
GIZZARD SHAD 89 4
GIZZARD SHAD 72 3
GOLDEN SHINER 71 8
SMALLMOUTH BUFFALO 49 3
ORCONECTES SP.
A-12 DRAFT
APPENDIX B Number, biomass, and relative abundance of shellfish and fish collected during impingement at LaSalle County Station by sampling date, April 2014-March 2015 DRAFT
B-1 APPENDIX B. NUMBER, BIOMASS, AND RELATIVE ABUNDANCE OF CRAYFISH, MUSSELS, AND FISH COLLECTED DURING IMPINGEMENT AT LASALLE STATION FOR EACH SAMPLING DATE, APRIL 2014 - MARCH 2015.
02-03 Apr 14 14-15 Apr 14 30 Apr-01 May 14 12-13 May 14 SPECIES
___KG__
___KG__
___KG__
___KG__
Orconectes sp.
Northern Clearwater Crayfish 1
12.50%
0.002 1.37%
Procambarus sp.
Fragile Papershell Pink Heelsplitter Paper Pondshell American Eel Gizzard Shad 1
12.50%
0.049 33.56%
1 2.13%
0.007 1.03%
Threadfin Shad Dorosoma sp.
Central Mudminnow Grass Pickerel Goldfish Common Carp Hornyhead Chub 1
1.04%
0.089 7.81%
Golden Shiner Emerald Shiner 1
1.04%
0.003 0.26%
Striped Shiner 1
1.04%
0.028 2.46%
Spottail Shiner 2
25.00%
0.010 6.85%
4 4.17%
0.025 2.19%
Silverband Shiner Spotfin Shiner 1
12.50%
0.001 0.68%
Notropis sp.
Bluntnose Minnow 30 31.25%
0.086 7.54%
Fathead Minnow 1
1.04%
0.006 0.53%
Bullhead Minnow Creek Chub 5
5.21%
0.017 1.49%
Cyprinidae sp.
1 1.04%
0.001 0.09%
White Sucker 5
5.21%
0.038 3.33%
Smallmouth Buffalo Black Redhorse Golden Redhorse 1
1.04%
0.083 7.28%
Oriental Weatherfish 1
1.04%
0.046 4.04%
Black Bullhead 2
2.08%
0.006 0.53%
Yellow Bullhead 1
1.04%
0.005 0.44%
Channel Catfish 1
2.13%
0.017 2.51%
Freckled Madtom Flathead Catfish 1
1.04%
0.003 0.26%
Brook Silverside Yellow Bass Green Sunfish Warmouth Orangespotted Sunfish 1
2.13%
0.010 1.47%
2 2.08%
0.015 1.32%
Bluegill 3
37.50%
0.084 57.53%
2 4.26%
0.004 0.59%
5 5.21%
0.040 3.51%
Lepomis sp.
Smallmouth Bass 1
1.04%
0.204 17.89%
Largemouth Bass Black Crappie Banded Darter 1
1.04%
0.001 0.09%
Walleye 1
2.13%
0.382 56.34%
Sander sp.
Freshwater Drum 9
9.38%
0.257 22.54%
Round Goby 41 87.23%
0.258 38.05%
1 100.00%
0.008 100.00%
23 23.96%
0.187 16.40%
Total Organisms 8
100.00%
0.146 100.00%
47 100.00%
0.678 100.00%
1 100.00%
0.008 100.00%
96 100.00%
1.140 100.00%
DRAFT
B-2 SPECIES Orconectes sp.
Northern Clearwater Crayfish Procambarus sp.
Fragile Papershell Pink Heelsplitter Paper Pondshell American Eel Gizzard Shad Threadfin Shad Dorosoma sp.
Central Mudminnow Grass Pickerel Goldfish Common Carp Hornyhead Chub Golden Shiner Emerald Shiner Striped Shiner Spottail Shiner Silverband Shiner Spotfin Shiner Notropis sp.
Bluntnose Minnow Fathead Minnow Bullhead Minnow Creek Chub Cyprinidae sp.
White Sucker Smallmouth Buffalo Black Redhorse Golden Redhorse Oriental Weatherfish Black Bullhead Yellow Bullhead Channel Catfish Freckled Madtom Flathead Catfish Brook Silverside Yellow Bass Green Sunfish Warmouth Orangespotted Sunfish Bluegill Lepomis sp.
Smallmouth Bass Largemouth Bass Black Crappie Banded Darter Walleye Sander sp.
Freshwater Drum Round Goby Total Organisms APPENDIX B (continued) 27-28 May 14 10-11 Jun 14 24-25 Jun 14 07-08 Jul 14
___KG__
___KG__
___KG__
___KG__
1 4.00%
0.000 1
7.14%
0.746 90.31%
5 20.00%
0.011 18.03%
12 46.15%
0.028 21.05%
3 12.00%
0.008 13.11%
1 3.85%
0.008 6.02%
2 7.69%
0.005 3.76%
7 28.00%
0.016 26.23%
2 28.57%
0.011 31.43%
1 14.29%
0.004 11.43%
1 7.14%
0.003 0.36%
1 7.14%
0.005 0.61%
1 3.85%
0.003 2.26%
1 14.29%
0.002 5.71%
8 57.14%
0.028 3.39%
2 7.69%
0.007 5.26%
1 3.85%
0.017 12.78%
1 14.29%
0.002 5.71%
2 14.29%
0.042 5.08%
2 7.69%
0.032 24.06%
1 14.29%
0.006 17.14%
1 3.85%
0.022 16.54%
1 7.14%
0.002 0.24%
1 4.00%
0.004 6.56%
1 4.00%
0.002 3.28%
1 3.85%
0.001 0.75%
2 8.00%
0.006 9.84%
4 16.00%
0.006 9.84%
1 3.85%
0.001 0.75%
1 14.29%
0.010 28.57%
2 7.69%
0.009 6.77%
1 4.00%
0.008 13.11%
7 100.00%
0.035 100.00%
14 100.00%
0.826 100.00%
26 100.00%
0.133 100.00%
25 100.00%
0.061 100.00%
DRAFT
B-3 SPECIES Orconectes sp.
Northern Clearwater Crayfish Procambarus sp.
Fragile Papershell Pink Heelsplitter Paper Pondshell American Eel Gizzard Shad Threadfin Shad Dorosoma sp.
Central Mudminnow Grass Pickerel Goldfish Common Carp Hornyhead Chub Golden Shiner Emerald Shiner Striped Shiner Spottail Shiner Silverband Shiner Spotfin Shiner Notropis sp.
Bluntnose Minnow Fathead Minnow Bullhead Minnow Creek Chub Cyprinidae sp.
White Sucker Smallmouth Buffalo Black Redhorse Golden Redhorse Oriental Weatherfish Black Bullhead Yellow Bullhead Channel Catfish Freckled Madtom Flathead Catfish Brook Silverside Yellow Bass Green Sunfish Warmouth Orangespotted Sunfish Bluegill Lepomis sp.
Smallmouth Bass Largemouth Bass Black Crappie Banded Darter Walleye Sander sp.
Freshwater Drum Round Goby Total Organisms APPENDIX B (continued) 28-29 Jul 14 11-12 Aug 14 25-26 Aug 14 07-08 Sep 14
___KG__
___KG__
___KG__
___KG__
1 9.09%
0.001 7.14%
3 9.38%
0.006 5.45%
30 90.91%
0.050 6.19%
7 28.00%
0.033 10.19%
4 12.50%
0.015 13.64%
5 45.45%
0.006 42.86%
4 16.00%
0.008 2.47%
14 43.75%
0.037 33.64%
1 9.09%
0.001 7.14%
7 28.00%
0.011 3.40%
4 12.50%
0.004 3.64%
2 6.06%
0.750 92.82%
1 3.13%
0.008 7.27%
1 4.00%
0.001 0.31%
1 9.09%
0.003 21.43%
1 3.13%
0.001 0.91%
1 4.00%
0.004 1.23%
1 4.00%
0.212 65.43%
2 6.25%
0.014 12.73%
1 4.00%
0.049 15.12%
1 3.13%
0.007 6.36%
1 9.09%
0.001 7.14%
2 18.18%
0.002 14.29%
2 8.00%
0.002 0.62%
1 3.13%
0.002 1.82%
1 3.13%
0.016 14.55%
1 3.03%
0.008 0.99%
1 4.00%
0.004 1.23%
33 100.00%
0.808 100.00%
11 100.00%
0.014 100.00%
25 100.00%
0.324 100.00%
32 100.00%
0.110 100.00%
DRAFT
B-4 SPECIES Orconectes sp.
Northern Clearwater Crayfish Procambarus sp.
Fragile Papershell Pink Heelsplitter Paper Pondshell American Eel Gizzard Shad Threadfin Shad Dorosoma sp.
Central Mudminnow Grass Pickerel Goldfish Common Carp Hornyhead Chub Golden Shiner Emerald Shiner Striped Shiner Spottail Shiner Silverband Shiner Spotfin Shiner Notropis sp.
Bluntnose Minnow Fathead Minnow Bullhead Minnow Creek Chub Cyprinidae sp.
White Sucker Smallmouth Buffalo Black Redhorse Golden Redhorse Oriental Weatherfish Black Bullhead Yellow Bullhead Channel Catfish Freckled Madtom Flathead Catfish Brook Silverside Yellow Bass Green Sunfish Warmouth Orangespotted Sunfish Bluegill Lepomis sp.
Smallmouth Bass Largemouth Bass Black Crappie Banded Darter Walleye Sander sp.
Freshwater Drum Round Goby Total Organisms APPENDIX B (continued) 22-23 Sep 14 24-25 Nov 14 15-16 Dec 14 22-23 Dec 14
___KG__
___KG__
___KG__
___KG__
1 1.61%
0.002 0.10%
1 5.26%
0.002 1.00%
1 1.08%
0.008 0.88%
2 6.90%
0.003 3.19%
1 3.45%
0.001 1.06%
2 3.23%
0.006 0.29%
5 17.24%
0.020 21.28%
2 3.23%
0.019 0.91%
11 57.89%
0.111 55.50%
78 83.87%
0.786 86.56%
18 62.07%
0.060 63.83%
2 3.23%
0.020 0.96%
4 4.30%
0.011 1.21%
5 8.06%
0.041 1.96%
1 5.26%
0.006 3.00%
3 4.84%
0.007 0.33%
1 3.45%
0.005 5.32%
1 1.61%
1.260 60.29%
4 6.45%
0.208 9.95%
1 3.45%
0.001 1.06%
1 1.61%
0.003 0.14%
1 1.08%
0.007 0.77%
14 22.58%
0.051 2.44%
1 1.61%
0.029 1.39%
1 3.45%
0.004 4.26%
8 12.90%
0.184 8.80%
1 5.26%
0.021 10.50%
3 3.23%
0.008 0.88%
2 3.23%
0.013 0.62%
1 5.26%
0.006 3.00%
2 3.23%
0.015 0.72%
14 22.58%
0.232 11.10%
4 21.05%
0.054 27.00%
6 6.45%
0.088 9.69%
29 100.00%
0.094 100.00%
62 100.00%
2.090 100.00%
19 100.00%
0.200 100.00%
93 100.00%
0.908 100.00%
DRAFT
B-5 SPECIES Orconectes sp.
Northern Clearwater Crayfish Procambarus sp.
Fragile Papershell Pink Heelsplitter Paper Pondshell American Eel Gizzard Shad Threadfin Shad Dorosoma sp.
Central Mudminnow Grass Pickerel Goldfish Common Carp Hornyhead Chub Golden Shiner Emerald Shiner Striped Shiner Spottail Shiner Silverband Shiner Spotfin Shiner Notropis sp.
Bluntnose Minnow Fathead Minnow Bullhead Minnow Creek Chub Cyprinidae sp.
White Sucker Smallmouth Buffalo Black Redhorse Golden Redhorse Oriental Weatherfish Black Bullhead Yellow Bullhead Channel Catfish Freckled Madtom Flathead Catfish Brook Silverside Yellow Bass Green Sunfish Warmouth Orangespotted Sunfish Bluegill Lepomis sp.
Smallmouth Bass Largemouth Bass Black Crappie Banded Darter Walleye Sander sp.
Freshwater Drum Round Goby Total Organisms APPENDIX B (continued) 26-27 Jan 15 09-10 Feb 15 16-17 Mar 15 30-31 Mar 15
___KG__
___KG__
___KG__
___KG__
1 7.69%
0.003 4.23%
3 10.00%
0.021 6.89%
33 58.93%
0.433 77.74%
4 15.38%
0.045 9.57%
1 3.33%
0.016 5.25%
3 23.08%
0.019 26.76%
1 1.79%
0.005 0.90%
8 26.67%
0.040 13.11%
2 15.38%
0.010 14.08%
11 19.64%
0.052 9.34%
6 23.08%
0.030 6.38%
7 23.33%
0.050 16.39%
1 3.85%
0.061 12.98%
1 7.69%
0.003 4.23%
1 3.33%
0.002 0.66%
5 19.23%
0.027 5.74%
3 5.36%
0.011 1.97%
1 7.69%
0.003 4.23%
1 7.69%
0.008 11.27%
1 1.79%
0.023 4.13%
2 6.67%
0.057 18.69%
1 3.33%
0.002 0.66%
1 7.69%
0.002 2.82%
2 3.57%
0.004 0.72%
2 6.67%
0.005 1.64%
1 1.79%
0.004 0.72%
3 5.36%
0.017 3.05%
4 15.38%
0.244 51.91%
5 16.67%
0.112 36.72%
1 1.79%
0.008 1.44%
3 11.54%
0.016 3.40%
3 11.54%
0.047 10.00%
3 23.08%
0.023 32.39%
56 100.00%
0.557 100.00%
26 100.00%
0.470 100.00%
30 100.00%
0.305 100.00%
13 100.00%
0.071 100.00%
DRAFT
APPENDIX C CPE by number (No. per volume) and weight (Kg. per volume) for shellfish and fish collected during impingement at LaSalle County Station by sampling date, April 2014-March 2015 DRAFT
C-1 APPENDIX C. CPE BY NUMBER (No. per million gallons) AND WEIGHT (Kg. per million gallons) FOR CRAYFISH, MUSSELS, AND FISH COLLECTED DURING IMPINGEMENT AT LASALLE STATION FOR EACH SAMPLING DATE, APRIL 2014 - MARCH 2015.
02-03 Apr 14 14-15 Apr 14 30 Apr-01 May 14 12-13 May 14 27-28 May 14 SPECIES
___#/MG___
__KG/MG___
___#/MG___
__KG/MG___
___#/MG___
__KG/MG___
___#/MG___
__KG/MG___
___#/MG___
__KG/MG___
Orconectes sp.
Northern Clearwater Crayfish 0.01157407 0.00002315 Procambarus sp.
Fragile Papershell Pink Heelsplitter Paper Pondshell American Eel Gizzard Shad 0.01157407 0.00056713 0.01157407 0.00008102 Threadfin Shad Dorosoma sp.
Central Mudminnow Grass Pickerel Goldfish Common Carp Hornyhead Chub 0.01155802 0.00102866 Golden Shiner Emerald Shiner 0.01155802 0.00003467 0.02311604 0.00012714 Striped Shiner 0.01155802 0.00032362 0.01155802 0.00004623 Spottail Shiner 0.02314815 0.00011574 0.04623209 0.00028895 Silverband Shiner Spotfin Shiner 0.01157407 0.00001157 Notropis sp.
Bluntnose Minnow 0.34674064 0.00099399 0.01155802 0.00002312 Fathead Minnow 0.01155802 0.00006935 Bullhead Minnow Creek Chub 0.05779011 0.00019649 Cyprinidae sp.
0.01155802 0.00001156 White Sucker 0.05779011 0.00043920 Smallmouth Buffalo Black Redhorse Golden Redhorse 0.01155802 0.00095932 Oriental Weatherfish 0.01155802 0.00053167 Black Bullhead 0.02311604 0.00006935 0.01155802 0.00002312 Yellow Bullhead 0.01155802 0.00005779 Channel Catfish 0.01157407 0.00019676 Freckled Madtom Flathead Catfish 0.01155802 0.00003467 0.01155802 0.00006935 Brook Silverside Yellow Bass Green Sunfish Warmouth Orangespotted Sunfish 0.01157407 0.00011574 0.02311604 0.00017337 Bluegill 0.03472222 0.00097222 0.02314815 0.00004630 0.05779011 0.00046232 Lepomis sp.
Smallmouth Bass 0.01155802 0.00235784 Largemouth Bass Black Crappie Banded Darter 0.01155802 0.00001156 Walleye 0.01157407 0.00442130 Sander sp.
Freshwater Drum 0.10402219 0.00297041 Round Goby 0.47453704 0.00298611 0.01163061 0.00009304 0.26583449 0.00216135 0.01155802 0.00011558 TOTAL ORGANISMS 0.09259259 0.00168981 0.54398148 0.00784722 0.01163061 0.00009304 1.10957004 0.01317614 0.08090615 0.00040453 DRAFT
C-2 SPECIES Orconectes sp.
Northern Clearwater Crayfish Procambarus sp.
Fragile Papershell Pink Heelsplitter Paper Pondshell American Eel Gizzard Shad Threadfin Shad Dorosoma sp.
Central Mudminnow Grass Pickerel Goldfish Common Carp Hornyhead Chub Golden Shiner Emerald Shiner Striped Shiner Spottail Shiner Silverband Shiner Spotfin Shiner Notropis sp.
Bluntnose Minnow Fathead Minnow Bullhead Minnow Creek Chub Cyprinidae sp.
White Sucker Smallmouth Buffalo Black Redhorse Golden Redhorse Oriental Weatherfish Black Bullhead Yellow Bullhead Channel Catfish Freckled Madtom Flathead Catfish Brook Silverside Yellow Bass Green Sunfish Warmouth Orangespotted Sunfish Bluegill Lepomis sp.
Smallmouth Bass Largemouth Bass Black Crappie Banded Darter Walleye Sander sp.
Freshwater Drum Round Goby TOTAL ORGANISMS APPENDIX C (continued) 10-11 Jun 14 24-25 Jun 14 07-08 Jul 14 28-29 Jul 14 11-12 Aug 14
___#/MG___
__KG/MG___
___#/MG___
__KG/MG___
___#/MG___
__KG/MG___
___#/MG___
__KG/MG___
___#/MG___
__KG/MG___
0.01164687 0.00000000 0.01157407 0.00001157 0.01157407 0.00863426 0.05823433 0.00012812 0.34843206 0.00058072 0.13888889 0.00032407 0.03494060 0.00009317 0.05787037 0.00006944 0.01157407 0.00001157 0.01157407 0.00009259 0.02314815 0.00005787 0.08152807 0.00018635 0.02322880 0.00871080 0.01157407 0.00003472 0.01157407 0.00005787 0.01157407 0.00003472 0.01157407 0.00003472 0.09259259 0.00032407 0.02314815 0.00008102 0.01157407 0.00019676 0.02314815 0.00048611 0.02314815 0.00037037 0.01157407 0.00025463 0.01157407 0.00001157 0.01157407 0.00002315 0.01164687 0.00004659 0.02314815 0.00002315 0.01164687 0.00002329 0.01157407 0.00001157 0.02329373 0.00006988 0.04658747 0.00006988 0.01157407 0.00001157 0.02314815 0.00010417 0.01164687 0.00009317 0.01161440 0.00009292 0.16203704 0.00956019 0.30092593 0.00153935 0.29117167 0.00071046 0.38327526 0.00938444 0.12731481 0.00016204 DRAFT
C-3 SPECIES Orconectes sp.
Northern Clearwater Crayfish Procambarus sp.
Fragile Papershell Pink Heelsplitter Paper Pondshell American Eel Gizzard Shad Threadfin Shad Dorosoma sp.
Central Mudminnow Grass Pickerel Goldfish Common Carp Hornyhead Chub Golden Shiner Emerald Shiner Striped Shiner Spottail Shiner Silverband Shiner Spotfin Shiner Notropis sp.
Bluntnose Minnow Fathead Minnow Bullhead Minnow Creek Chub Cyprinidae sp.
White Sucker Smallmouth Buffalo Black Redhorse Golden Redhorse Oriental Weatherfish Black Bullhead Yellow Bullhead Channel Catfish Freckled Madtom Flathead Catfish Brook Silverside Yellow Bass Green Sunfish Warmouth Orangespotted Sunfish Bluegill Lepomis sp.
Smallmouth Bass Largemouth Bass Black Crappie Banded Darter Walleye Sander sp.
Freshwater Drum Round Goby TOTAL ORGANISMS APPENDIX C (continued) 25-26 Aug 14 07-08 Sep 14 22-23 Sep 14 24-25 Nov 14 15-16 Dec 14
___#/MG___
__KG/MG___
___#/MG___
__KG/MG___
___#/MG___
__KG/MG___
___#/MG___
__KG/MG___
___#/MG___
__KG/MG___
0.01155001 0.00002310 0.01147842 0.00002296 0.02244669 0.00003367 0.03436426 0.00006873 0.01122334 0.00001122 0.02310002 0.00006930 0.08068234 0.00038036 0.04581901 0.00017182 0.05611672 0.00022447 0.02310002 0.00021945 0.12626263 0.00127410 0.04610420 0.00009221 0.16036655 0.00042383 0.20202020 0.00067340 0.02310002 0.00023100 0.08068234 0.00012679 0.04581901 0.00004582 0.05775006 0.00047355 0.01145475 0.00009164 0.01147842 0.00006887 0.01152605 0.00001153 0.01145475 0.00001145 0.03465003 0.00008085 0.01122334 0.00005612 0.01155001 0.01455301 0.01152605 0.00004610 0.04620005 0.00240240 0.01152605 0.00244352 0.02290951 0.00016037 0.01122334 0.00001122 0.01155001 0.00003465 0.01152605 0.00056478 0.01145475 0.00008018 0.16170016 0.00058905 0.01155001 0.00033495 0.02305210 0.00002305 0.01145475 0.00002291 0.01122334 0.00004489 0.09240009 0.00212520 0.01147842 0.00024105 0.02310002 0.00015015 0.01147842 0.00006887 0.02310002 0.00017325 0.01145475 0.00018328 0.16170016 0.00267960 0.04591368 0.00061983 0.01152605 0.00004610 0.28815122 0.00373444 0.36655212 0.00126002 0.32547699 0.00105499 0.71610072 0.02413952 0.21808999 0.00229568 DRAFT
C-4 SPECIES Orconectes sp.
Northern Clearwater Crayfish Procambarus sp.
Fragile Papershell Pink Heelsplitter Paper Pondshell American Eel Gizzard Shad Threadfin Shad Dorosoma sp.
Central Mudminnow Grass Pickerel Goldfish Common Carp Hornyhead Chub Golden Shiner Emerald Shiner Striped Shiner Spottail Shiner Silverband Shiner Spotfin Shiner Notropis sp.
Bluntnose Minnow Fathead Minnow Bullhead Minnow Creek Chub Cyprinidae sp.
White Sucker Smallmouth Buffalo Black Redhorse Golden Redhorse Oriental Weatherfish Black Bullhead Yellow Bullhead Channel Catfish Freckled Madtom Flathead Catfish Brook Silverside Yellow Bass Green Sunfish Warmouth Orangespotted Sunfish Bluegill Lepomis sp.
Smallmouth Bass Largemouth Bass Black Crappie Banded Darter Walleye Sander sp.
Freshwater Drum Round Goby TOTAL ORGANISMS APPENDIX C (continued) 22-23 Dec 14 26-27 Jan 15 09-10 Feb 15 16-17 Mar 15 30-31 Mar 15
___#/MG___
__KG/MG___
___#/MG___
__KG/MG___
___#/MG___
__KG/MG___
___#/MG___
__KG/MG___
___#/MG___
__KG/MG___
0.01159017 0.00003477 0.01157407 0.00009259 0.03467406 0.00024272 0.90277778 0.00909722 0.38434661 0.00504309 0.04610420 0.00051867 0.01155802 0.00018493 0.03477051 0.00022021 0.01164687 0.00005823 0.04629630 0.00012731 0.09246417 0.00046232 0.02318034 0.00011590 0.12811554 0.00060564 0.06915629 0.00034578 0.08090615 0.00057790 0.01152605 0.00070309 0.01159017 0.00003477 0.01155802 0.00002312 0.05763024 0.00031120 0.03494060 0.00012812 0.01159017 0.00003477 0.01159017 0.00009272 0.01164687 0.00026788 0.02311604 0.00065881 0.01155802 0.00002312 0.01159017 0.00002318 0.01157407 0.00008102 0.02329373 0.00004659 0.02311604 0.00005779 0.01164687 0.00004659 0.03472222 0.00009259 0.03494060 0.00019800 0.04610420 0.00281236 0.05779011 0.00129450 0.01164687 0.00009317 0.03457815 0.00018442 0.06944444 0.00101852 0.03457815 0.00054172 0.03477051 0.00026657 1.07638889 0.01050926 0.65222455 0.00648730 0.29967727 0.00541724 0.34674064 0.00352520 0.15067223 0.00082290 DRAFT
APPENDIX D Raw Ichthyoplankton Entrainment Data Collected at LaSalle County Station, April 2014-August 2014 DRAFT
APPENDIX D - RAW ENTRAINMENT DATA LISTING, LASALLE COUNTY STATION, 2014.
SAMPLE DATE: 3 April START DATE and TIME: 03APR14:18:02 SAMPLE DURATION (minutes): 23.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.013674 STUDY GRAB TEMPERATURE (F): 47.5 STUDY GRAB DISSOLVED OXYGEN (mg/L): 11.4 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 30 March-16 April MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1555.2 LIFE PLUS TAXA STAGE LENGTH COUNT NO ICHTHYOPLANKTON.. 0 SAMPLE DATE: 3 April START DATE and TIME: 03APR14:18:02 SAMPLE DURATION (minutes): 20.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.014106 STUDY GRAB TEMPERATURE (F): 47.5 STUDY GRAB DISSOLVED OXYGEN (mg/L): 11.4 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 30 March-16 April MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1555.2 LIFE PLUS TAXA STAGE LENGTH COUNT NO ICHTHYOPLANKTON.. 0 SAMPLE DATE: 3 April START DATE and TIME: 03APR14:18:53 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.014829 STUDY GRAB TEMPERATURE (F): 47.5 STUDY GRAB DISSOLVED OXYGEN (mg/L): 11.4 FOREBAY CURRENT VELOCITY (ft/sec): 1.30 EXTRAPOLATION PERIOD: 30 March-16 April MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1555.2 LIFE PLUS TAXA STAGE LENGTH COUNT NO ICHTHYOPLANKTON.. 0 SAMPLE DATE: 3 April START DATE and TIME: 03APR14:18:53 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.014950 STUDY GRAB TEMPERATURE (F): 47.5 STUDY GRAB DISSOLVED OXYGEN (mg/L): 11.4 FOREBAY CURRENT VELOCITY (ft/sec): 1.30 EXTRAPOLATION PERIOD: 30 March-16 April MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1555.2 LIFE PLUS TAXA STAGE LENGTH COUNT NO ICHTHYOPLANKTON.. 0 SAMPLE DATE: 3 April START DATE and TIME: 03APR14:20:51 SAMPLE DURATION (minutes): 20.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.015076 STUDY GRAB TEMPERATURE (F): 47.5 STUDY GRAB DISSOLVED OXYGEN (mg/L): 11.2 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 30 March-16 April MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1555.2 LIFE PLUS TAXA STAGE LENGTH COUNT FRESHWATER DRUM Egg 1.5.
SAMPLE DATE: 3 April START DATE and TIME: 03APR14:20:51 SAMPLE DURATION (minutes): 20.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.018947 STUDY GRAB TEMPERATURE (F): 47.5 STUDY GRAB DISSOLVED OXYGEN (mg/L): 11.2 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 30 March-16 April MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1555.2 LIFE PLUS TAXA STAGE LENGTH COUNT NO ICHTHYOPLANKTON.. 0 SAMPLE DATE: 3 April START DATE and TIME: 03APR14:21:30 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.013705 STUDY GRAB TEMPERATURE (F): 47.7 STUDY GRAB DISSOLVED OXYGEN (mg/L): 11.2 FOREBAY CURRENT VELOCITY (ft/sec): 1.30 EXTRAPOLATION PERIOD: 30 March-16 April MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1555.2 LIFE PLUS TAXA STAGE LENGTH COUNT NO ICHTHYOPLANKTON.. 0 SAMPLE DATE: 3 April START DATE and TIME: 03APR14:21:30 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.014804 STUDY GRAB TEMPERATURE (F): 47.7 STUDY GRAB DISSOLVED OXYGEN (mg/L): 11.2 FOREBAY CURRENT VELOCITY (ft/sec): 1.30 EXTRAPOLATION PERIOD: 30 March-16 April MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1555.2 LIFE PLUS TAXA STAGE LENGTH COUNT NO ICHTHYOPLANKTON.. 0 D-1 DRAFT
APPENDIX D (cont.)
SAMPLE DATE: 24 April START DATE and TIME: 24APR14:17:40 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.015063 STUDY GRAB TEMPERATURE (F): 60.6 STUDY GRAB DISSOLVED OXYGEN (mg/L): 14.3 FOREBAY CURRENT VELOCITY (ft/sec): 1.60 EXTRAPOLATION PERIOD: 17 April-3 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1468.8 LIFE PLUS TAXA STAGE LENGTH COUNT Morone sp. Yolk-sac 3.0.
LOGPERCH type Yolk-sac 6.9.
LOGPERCH type Yolk-sac 6.4.
SAMPLE DATE: 24 April START DATE and TIME: 24APR14:18:10 SAMPLE DURATION (minutes): 14.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.018359 STUDY GRAB TEMPERATURE (F): 60.6 STUDY GRAB DISSOLVED OXYGEN (mg/L): 13.6 FOREBAY CURRENT VELOCITY (ft/sec): 1.60 EXTRAPOLATION PERIOD: 17 April-3 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1468.8 LIFE PLUS TAXA STAGE LENGTH COUNT UNIDENTIFIED Yolk-sac 5.9.
SAMPLE DATE: 24 April START DATE and TIME: 24APR14:18:40 SAMPLE DURATION (minutes): 22.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.015395 STUDY GRAB TEMPERATURE (F): 60.4 STUDY GRAB DISSOLVED OXYGEN (mg/L): 12.9 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 17 April-3 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1468.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 7.2.
Dorosoma sp. Post Yolk-sac 6.0.
LOGPERCH type Yolk-sac 6.2.
LOGPERCH type Yolk-sac 5.8.
LOGPERCH type Yolk-sac 6.2.
LOGPERCH type Yolk-sac 9.0.
LOGPERCH type Yolk-sac 6.4.
LOGPERCH type Yolk-sac 6.5.
LOGPERCH type Yolk-sac 6.4.
LOGPERCH type Yolk-sac 8.5.
SAMPLE DATE: 24 April START DATE and TIME: 24APR14:18:40 SAMPLE DURATION (minutes): 12.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.016079 STUDY GRAB TEMPERATURE (F): 60.4 STUDY GRAB DISSOLVED OXYGEN (mg/L): 12.9 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 17 April-3 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1468.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 5.7.
Morone sp. Yolk-sac 2.7.
Morone sp. Yolk-sac 3.0.
Morone sp. Yolk-sac 2.8.
LOGPERCH type Yolk-sac 6.5.
LOGPERCH type Yolk-sac 6.0.
LOGPERCH type Yolk-sac 8.0.
SAMPLE DATE: 24 April START DATE and TIME: 24APR14:21:45 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.017476 STUDY GRAB TEMPERATURE (F): 59.7 STUDY GRAB DISSOLVED OXYGEN (mg/L): 11.5 FOREBAY CURRENT VELOCITY (ft/sec): 1.60 EXTRAPOLATION PERIOD: 17 April-3 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1468.8 LIFE PLUS TAXA STAGE LENGTH COUNT Morone sp. Yolk-sac 3.1.
Sander sp. Yolk-sac 8.1.
Sander sp. Yolk-sac 8.5.
Sander sp. Yolk-sac 7.9.
Sander sp. Yolk-sac 8.2.
Sander sp. Yolk-sac 8.0.
Sander sp. Yolk-sac 9.4.
Sander sp. Yolk-sac 7.8.
LOGPERCH type Yolk-sac 6.0.
LOGPERCH type Yolk-sac 7.2.
LOGPERCH type Yolk-sac 6.7.
LOGPERCH type Yolk-sac 6.5.
UNIDENTIFIED Yolk-sac 5.7.
D-2 DRAFT
APPENDIX D (cont.)
SAMPLE DATE: 24 April START DATE and TIME: 24APR14:21:45 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.015715 STUDY GRAB TEMPERATURE (F): 59.7 STUDY GRAB DISSOLVED OXYGEN (mg/L): 11.5 FOREBAY CURRENT VELOCITY (ft/sec): 1.60 EXTRAPOLATION PERIOD: 17 April-3 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1468.8 LIFE PLUS TAXA STAGE LENGTH COUNT Sander sp. Yolk-sac 8.7.
Sander sp. Yolk-sac 8.2.
Sander sp. Yolk-sac 7.9.
Sander sp. Yolk-sac 7.9.
Sander sp. Yolk-sac 8.2.
Sander sp. Yolk-sac 8.1.
Sander sp. Yolk-sac 8.0.
LOGPERCH type Yolk-sac 6.4.
LOGPERCH type Yolk-sac 7.3.
SAMPLE DATE: 24 April START DATE and TIME: 24APR14:22:17 SAMPLE DURATION (minutes): 12.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.013408 STUDY GRAB TEMPERATURE (F): 59.7 STUDY GRAB DISSOLVED OXYGEN (mg/L): 11.2 FOREBAY CURRENT VELOCITY (ft/sec): 1.30 EXTRAPOLATION PERIOD: 17 April-3 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1468.8 LIFE PLUS TAXA STAGE LENGTH COUNT Sander sp. Yolk-sac 8.3.
Sander sp. Yolk-sac 7.9.
Sander sp. Yolk-sac 7.8.
Sander sp. Yolk-sac 8.4.
Sander sp. Yolk-sac 7.6.
Sander sp. Yolk-sac 7.0.
LOGPERCH type Yolk-sac 7.0.
SAMPLE DATE: 24 April START DATE and TIME: 24APR14:22:17 SAMPLE DURATION (minutes): 12.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.015636 STUDY GRAB TEMPERATURE (F): 59.7 STUDY GRAB DISSOLVED OXYGEN (mg/L): 11.2 FOREBAY CURRENT VELOCITY (ft/sec): 1.30 EXTRAPOLATION PERIOD: 17 April-3 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1468.8 LIFE PLUS TAXA STAGE LENGTH COUNT ICTIOBINAE sp. Yolk-sac 5.7.
Sander sp. Yolk-sac 8.0.
Sander sp. Yolk-sac 7.5.
Sander sp. Yolk-sac 8.2.
Sander sp. Yolk-sac 8.2.
Sander sp. Yolk-sac 9.3.
Sander sp. Yolk-sac 8.0.
Sander sp. Yolk-sac 7.8.
LOGPERCH type Yolk-sac 6.8.
LOGPERCH type Yolk-sac 6.7.
LOGPERCH type Yolk-sac 6.6.
SAMPLE DATE: 6 May START DATE and TIME: 06MAY14:18:23 SAMPLE DURATION (minutes): 16.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.021023 STUDY GRAB TEMPERATURE (F): 60.8 STUDY GRAB DISSOLVED OXYGEN (mg/L): 13.6 FOREBAY CURRENT VELOCITY (ft/sec): 0.90 EXTRAPOLATION PERIOD: 4-10 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 7.4.
Dorosoma sp. Post Yolk-sac 8.3.
Dorosoma sp. Post Yolk-sac 7.4.
ICTIOBINAE sp. Yolk-sac 8.1.
ICTIOBINAE sp. Yolk-sac 7.5.
Morone sp. Yolk-sac 3.2.
LOGPERCH type Yolk-sac 6.9.
LOGPERCH type Yolk-sac 5.6.
SAMPLE DATE: 6 May START DATE and TIME: 06MAY14:18:23 SAMPLE DURATION (minutes): 16.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.020882 STUDY GRAB TEMPERATURE (F): 60.8 STUDY GRAB DISSOLVED OXYGEN (mg/L): 13.6 FOREBAY CURRENT VELOCITY (ft/sec): 0.90 EXTRAPOLATION PERIOD: 4-10 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 7.5.
Dorosoma sp. Post Yolk-sac 7.3.
ICTIOBINAE sp. Yolk-sac 7.1.
ICTIOBINAE sp. Yolk-sac 6.7.
D-3 DRAFT
APPENDIX D (cont.)
SAMPLE DATE: 6 May START DATE and TIME: 06MAY14:18:56 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.016915 STUDY GRAB TEMPERATURE (F): 60.6 STUDY GRAB DISSOLVED OXYGEN (mg/L): 13.6 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 4-10 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT ICTIOBINAE sp. Yolk-sac 8.0.
ICTIOBINAE sp. Yolk-sac 7.2.
Sander sp. Yolk-sac 9.5.
LOGPERCH type Yolk-sac 6.3.
LOGPERCH type Yolk-sac 6.5.
SAMPLE DATE: 6 May START DATE and TIME: 06MAY14:18:56 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.014484 STUDY GRAB TEMPERATURE (F): 60.6 STUDY GRAB DISSOLVED OXYGEN (mg/L): 13.6 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 4-10 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 8.1.
Dorosoma sp. Post Yolk-sac 9.3.
ICTIOBINAE sp. Yolk-sac 7.7.
SAMPLE DATE: 6 May START DATE and TIME: 06MAY14:21:01 SAMPLE DURATION (minutes): 12.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.015896 STUDY GRAB TEMPERATURE (F): 59.7 STUDY GRAB DISSOLVED OXYGEN (mg/L): 10.2 FOREBAY CURRENT VELOCITY (ft/sec): 1.20 EXTRAPOLATION PERIOD: 4-10 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.7.
ICTIOBINAE sp. Yolk-sac 7.4.
ICTIOBINAE sp. Yolk-sac 7.8.
ICTIOBINAE sp. Yolk-sac 7.6.
ICTIOBINAE sp. Yolk-sac 7.1.
ICTIOBINAE sp. Yolk-sac 7.4.
ICTIOBINAE sp. Yolk-sac 7.9.
ICTIOBINAE sp. Yolk-sac 7.1.
ICTIOBINAE sp. Yolk-sac 8.2.
ICTIOBINAE sp. Yolk-sac 7.4.
ICTIOBINAE sp. Yolk-sac 7.5.
ICTIOBINAE sp. Yolk-sac 7.7.
ICTIOBINAE sp. Yolk-sac 7.8.
ICTIOBINAE sp. Yolk-sac 8.0.
ICTIOBINAE sp. Yolk-sac 6.8.
ICTIOBINAE sp. Yolk-sac 8.3.
ICTIOBINAE sp. Yolk-sac 7.9.
ICTIOBINAE sp. Yolk-sac 7.8.
ICTIOBINAE sp. Yolk-sac 6.8.
ICTIOBINAE sp. Yolk-sac 7.7.
ICTIOBINAE sp. Yolk-sac 7.5.
UNIDENTIFIED Yolk-sac 5.5.
UNIDENTIFIED Yolk-sac 5.4.
SAMPLE DATE: 6 May START DATE and TIME: 06MAY14:21:01 SAMPLE DURATION (minutes): 12.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.016160 STUDY GRAB TEMPERATURE (F): 59.7 STUDY GRAB DISSOLVED OXYGEN (mg/L): 10.2 FOREBAY CURRENT VELOCITY (ft/sec): 1.20 EXTRAPOLATION PERIOD: 4-10 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT ICTIOBINAE sp. Yolk-sac 7.0.
ICTIOBINAE sp. Yolk-sac 7.6.
ICTIOBINAE sp. Yolk-sac 7.5.
ICTIOBINAE sp. Yolk-sac 7.7.
ICTIOBINAE sp. Yolk-sac 7.6.
ICTIOBINAE sp. Yolk-sac 7.4.
ICTIOBINAE sp. Yolk-sac 7.5.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.6.
ICTIOBINAE sp. Yolk-sac 7.5.
ICTIOBINAE sp. Yolk-sac 7.8.
ICTIOBINAE sp. Yolk-sac 7.6.
ICTIOBINAE sp. Yolk-sac 8.0.
ICTIOBINAE sp. Yolk-sac 7.9.
ICTIOBINAE sp. Yolk-sac 6.7.
ICTIOBINAE sp. Yolk-sac 6.8.
UNIDENTIFIED Yolk-sac 5.4.
UNIDENTIFIED Yolk-sac 5.3.
D-4 DRAFT
APPENDIX D (cont.)
SAMPLE DATE: 6 May START DATE and TIME: 06MAY14:21:26 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.013851 STUDY GRAB TEMPERATURE (F): 59.7 STUDY GRAB DISSOLVED OXYGEN (mg/L): 10.2 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 4-10 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 9.0.
ICTIOBINAE sp. Yolk-sac 7.6.
ICTIOBINAE sp. Yolk-sac 7.8.
ICTIOBINAE sp. Yolk-sac 8.4.
ICTIOBINAE sp. Yolk-sac 8.2.
ICTIOBINAE sp. Yolk-sac 7.7.
ICTIOBINAE sp. Yolk-sac 7.8.
ICTIOBINAE sp. Yolk-sac 7.0.
SAMPLE DATE: 6 May START DATE and TIME: 06MAY14:21:26 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.015163 STUDY GRAB TEMPERATURE (F): 59.7 STUDY GRAB DISSOLVED OXYGEN (mg/L): 10.2 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 4-10 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Yolk-sac 8.6.
ICTIOBINAE sp. Yolk-sac 8.5.
ICTIOBINAE sp. Yolk-sac 8.6.
ICTIOBINAE sp. Yolk-sac 7.6.
ICTIOBINAE sp. Yolk-sac 7.8.
ICTIOBINAE sp. Yolk-sac 8.1.
ICTIOBINAE sp. Yolk-sac 8.3.
ICTIOBINAE sp. Yolk-sac 7.8.
ICTIOBINAE sp. Yolk-sac 7.9.
ICTIOBINAE sp. Yolk-sac 7.1.
ICTIOBINAE sp. Yolk-sac 7.6.
ICTIOBINAE sp. Yolk-sac 8.0.
ICTIOBINAE sp. Yolk-sac 8.3.
ICTIOBINAE sp. Yolk-sac 8.3.
ICTIOBINAE sp. Yolk-sac 8.2.
ICTIOBINAE sp. Yolk-sac 7.9.
Sander sp. Yolk-sac 9.3.
SAMPLE DATE: 13 May START DATE and TIME: 13MAY14:18:37 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.015182 STUDY GRAB TEMPERATURE (F): 68.0 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.2 FOREBAY CURRENT VELOCITY (ft/sec): 1.40 EXTRAPOLATION PERIOD: 11-17 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT COMMON CARP Yolk-sac 7.0.
COMMON CARP Yolk-sac 7.1.
COMMON CARP Yolk-sac 7.1.
COMMON CARP Yolk-sac 6.8.
COMMON CARP Yolk-sac 6.8.
COMMON CARP Yolk-sac 6.8.
COMMON CARP Yolk-sac 7.2.
COMMON CARP Yolk-sac 6.8.
COMMON CARP Yolk-sac 7.1.
COMMON CARP Yolk-sac 7.2.
COMMON CARP Yolk-sac 6.8.
COMMON CARP Yolk-sac 6.4.
COMMON CARP Yolk-sac 6.8.
COMMON CARP Yolk-sac 7.4.
COMMON CARP Yolk-sac 6.8.
COMMON CARP Yolk-sac 6.6.
COMMON CARP Yolk-sac 7.2.
COMMON CARP Yolk-sac 7.0.
COMMON CARP Yolk-sac 6.8.
COMMON CARP Yolk-sac 6.4.
COMMON CARP Egg 1.8.
COMMON CARP Egg 1.8.
COMMON CARP Egg 1.8.
COMMON CARP Yolk-sac. 41 Moxostoma sp. Post Yolk-sac 14.2.
Moxostoma sp. Post Yolk-sac 13.6.
Moxostoma sp. Yolk-sac 10.8.
ICTIOBINAE sp. Yolk-sac 9.1.
ICTIOBINAE sp. Yolk-sac 9.3.
ICTIOBINAE sp. Yolk-sac 8.7.
ICTIOBINAE sp. Yolk-sac 8.8.
ICTIOBINAE sp. Yolk-sac 8.5.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.6.
ICTIOBINAE sp. Yolk-sac 7.2.
D-5 DRAFT
APPENDIX D (cont.)
ICTIOBINAE sp. Yolk-sac 7.3.
ICTIOBINAE sp. Yolk-sac 7.3.
ICTIOBINAE sp. Yolk-sac 7.4.
ICTIOBINAE sp. Yolk-sac 6.9.
ICTIOBINAE sp. Yolk-sac 7.3.
ICTIOBINAE sp. Yolk-sac 6.9.
ICTIOBINAE sp. Yolk-sac 6.7.
ICTIOBINAE sp. Yolk-sac 6.9.
ICTIOBINAE sp. Yolk-sac 6.7.
ICTIOBINAE sp. Yolk-sac 7.7.
ICTIOBINAE sp. Yolk-sac 6.8.
ICTIOBINAE sp. Yolk-sac 6.8.
ICTIOBINAE sp. Yolk-sac 7.4.
ICTIOBINAE sp. Yolk-sac. 52 ICTIOBINAE sp. Yolk-sac. 13 LOGPERCH type Yolk-sac 6.2.
LOGPERCH type Yolk-sac 6.9.
LOGPERCH type Yolk-sac 6.1.
DARTER sp. Post Yolk-sac 10.1.
DARTER sp. Post Yolk-sac 7.8.
DARTER sp. Yolk-sac 7.7.
DARTER sp. Yolk-sac 6.0.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.4.
UNIDENTIFIED Yolk-sac 6.0.
SAMPLE DATE: 13 May START DATE and TIME: 13MAY14:18:11 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.014277 STUDY GRAB TEMPERATURE (F): 68.0 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.2 FOREBAY CURRENT VELOCITY (ft/sec): 1.40 EXTRAPOLATION PERIOD: 11-17 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 8.5.
Dorosoma sp. Post Yolk-sac 5.3.
Dorosoma sp. Post Yolk-sac 5.6.
Dorosoma sp. Post Yolk-sac 5.3.
COMMON CARP Yolk-sac 6.2.
COMMON CARP Yolk-sac 6.2.
COMMON CARP Yolk-sac 6.1.
COMMON CARP Yolk-sac 7.1.
COMMON CARP Yolk-sac 6.7.
COMMON CARP Yolk-sac 7.2.
COMMON CARP Yolk-sac 6.2.
COMMON CARP Yolk-sac 6.8.
COMMON CARP Yolk-sac 7.6.
COMMON CARP Yolk-sac 7.0.
COMMON CARP Yolk-sac 6.3.
COMMON CARP Yolk-sac 6.7.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 5.9.
COMMON CARP Yolk-sac 6.4.
COMMON CARP Yolk-sac 6.3.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 6.2.
COMMON CARP Yolk-sac 7.1.
COMMON CARP Yolk-sac 6.0.
COMMON CARP Yolk-sac. 28 Semotilus type Yolk-sac 9.0.
Semotilus type Yolk-sac 9.3.
Semotilus type Yolk-sac 9.2.
ICTIOBINAE sp. Yolk-sac 6.2.
ICTIOBINAE sp. Yolk-sac 7.4.
ICTIOBINAE sp. Yolk-sac 8.7.
ICTIOBINAE sp. Yolk-sac 6.9.
ICTIOBINAE sp. Yolk-sac 7.1.
ICTIOBINAE sp. Yolk-sac 7.5.
ICTIOBINAE sp. Yolk-sac 6.4.
ICTIOBINAE sp. Yolk-sac 7.4.
ICTIOBINAE sp. Yolk-sac 6.8.
ICTIOBINAE sp. Yolk-sac 7.6.
ICTIOBINAE sp. Yolk-sac 7.4.
ICTIOBINAE sp. Yolk-sac 7.6.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.5.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.9.
ICTIOBINAE sp. Yolk-sac 6.8.
ICTIOBINAE sp. Yolk-sac 7.0.
ICTIOBINAE sp. Yolk-sac 6.9.
D-6 DRAFT
APPENDIX D (cont.)
ICTIOBINAE sp. Yolk-sac 6.7.
ICTIOBINAE sp. Yolk-sac 7.1.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac. 48 ICTIOBINAE sp. Yolk-sac 10.0.
ICTIOBINAE sp. Yolk-sac 9.8.
ICTIOBINAE sp. Yolk-sac 9.7.
ICTIOBINAE sp. Yolk-sac 8.3.
ICTIOBINAE sp. Yolk-sac. 3 ICTIOBINAE sp. Yolk-sac. 9 ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 5.9.
CATOSTOMIDAE sp. Yolk-sac 3.6.
CATOSTOMIDAE sp. Yolk-sac 5.5.
CATOSTOMIDAE sp. Yolk-sac 5.4.
LOGPERCH type Yolk-sac 5.6.
LOGPERCH type Yolk-sac 5.9.
LOGPERCH type Yolk-sac 6.2.
LOGPERCH type Yolk-sac 5.2.
LOGPERCH type Yolk-sac 6.2.
LOGPERCH type Yolk-sac 6.8.
DARTER sp. Yolk-sac 6.0.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
UNIDENTIFIED Yolk-sac 5.4.
UNIDENTIFIED Yolk-sac 5.3.
UNIDENTIFIED Egg 1.1.
UNIDENTIFIED Egg 1.2.
UNIDENTIFIED Egg 1.1.
SAMPLE DATE: 13 May START DATE and TIME: 13MAY14:18:55 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.014638 STUDY GRAB TEMPERATURE (F): 67.8 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.2 FOREBAY CURRENT VELOCITY (ft/sec): 1.30 EXTRAPOLATION PERIOD: 11-17 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 5.8.
Dorosoma sp. Post Yolk-sac 5.7.
COMMON CARP Yolk-sac 6.8.
COMMON CARP Yolk-sac 5.9.
COMMON CARP Yolk-sac 6.9.
COMMON CARP Yolk-sac 7.1.
COMMON CARP Yolk-sac 7.0.
COMMON CARP Yolk-sac 6.9.
COMMON CARP Yolk-sac 7.4.
COMMON CARP Yolk-sac 6.7.
COMMON CARP Yolk-sac 6.6.
COMMON CARP Yolk-sac 6.3.
COMMON CARP Yolk-sac 6.8.
COMMON CARP Yolk-sac 6.3.
COMMON CARP Yolk-sac 6.6.
COMMON CARP Yolk-sac 6.7.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 7.1.
COMMON CARP Yolk-sac 7.6.
COMMON CARP Yolk-sac 6.9.
COMMON CARP Yolk-sac 6.2.
COMMON CARP Yolk-sac 7.2.
COMMON CARP Yolk-sac. 38 COMMON CARP Egg 1.4.
COMMON CARP Egg 1.5.
Semotilus type Yolk-sac 9.4.
Semotilus type Yolk-sac 9.3.
Semotilus type Yolk-sac 9.8.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 6.6.
CYPRINIDAE sp. Yolk-sac 5.8.
ICTIOBINAE sp. Yolk-sac 9.1.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.6.
ICTIOBINAE sp. Yolk-sac 7.3.
ICTIOBINAE sp. Yolk-sac 7.1.
ICTIOBINAE sp. Yolk-sac 7.4.
D-7 DRAFT
APPENDIX D (cont.)
ICTIOBINAE sp. Yolk-sac 8.0.
ICTIOBINAE sp. Yolk-sac 7.9.
ICTIOBINAE sp. Yolk-sac 7.3.
ICTIOBINAE sp. Yolk-sac 7.1.
ICTIOBINAE sp. Yolk-sac 7.6.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.0.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.1.
ICTIOBINAE sp. Yolk-sac 7.9.
ICTIOBINAE sp. Yolk-sac 7.1.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.1.
ICTIOBINAE sp. Yolk-sac 7.4.
ICTIOBINAE sp. Yolk-sac 7.5.
ICTIOBINAE sp. Yolk-sac. 36 ICTIOBINAE sp. Yolk-sac. 1 Sander sp. Post Yolk-sac 10.0.
LOGPERCH type Yolk-sac 6.2.
LOGPERCH type Yolk-sac 5.9.
LOGPERCH type Yolk-sac 6.6.
LOGPERCH type Yolk-sac 4.5.
DARTER sp. Yolk-sac 6.2.
DARTER sp. Yolk-sac 6.0.
DARTER sp. Yolk-sac 6.3.
DARTER sp. Yolk-sac 5.8.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.8.
FRESHWATER DRUM Egg 1.7.
FRESHWATER DRUM Egg 1.7.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.7.
FRESHWATER DRUM Egg 1.9.
UNIDENTIFIED Egg 1.0.
UNIDENTIFIED Egg 1.0.
UNIDENTIFIED Egg 1.1.
UNIDENTIFIED Egg 0.9.
UNIDENTIFIED Egg 0.9.
SAMPLE DATE: 13 May START DATE and TIME: 13MAY14:18:55 SAMPLE DURATION (minutes): 18.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.014900 STUDY GRAB TEMPERATURE (F): 67.8 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.2 FOREBAY CURRENT VELOCITY (ft/sec): 1.30 EXTRAPOLATION PERIOD: 11-17 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 5.1.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 5.9.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 6.0.
COMMON CARP Yolk-sac 6.6.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 7.0.
COMMON CARP Yolk-sac 6.8.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 5.6.
COMMON CARP Yolk-sac 6.6.
COMMON CARP Yolk-sac 6.7.
COMMON CARP Yolk-sac 6.3.
COMMON CARP Yolk-sac 6.0.
COMMON CARP Yolk-sac 6.6.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 6.2.
COMMON CARP Yolk-sac 6.0.
COMMON CARP Yolk-sac 6.8.
COMMON CARP Yolk-sac 6.1.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 5.5.
CYPRINIDAE sp. Yolk-sac 6.1.
D-8 DRAFT
APPENDIX D (cont.)
CYPRINIDAE sp. Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 5.7.
ICTIOBINAE sp. Post Yolk-sac 9.5.
ICTIOBINAE sp. Post Yolk-sac 9.0.
ICTIOBINAE sp. Post Yolk-sac 8.6.
ICTIOBINAE sp. Post Yolk-sac 8.8.
ICTIOBINAE sp. Post Yolk-sac 8.6.
ICTIOBINAE sp. Post Yolk-sac 9.7.
ICTIOBINAE sp. Yolk-sac 7.3.
ICTIOBINAE sp. Yolk-sac 7.6.
ICTIOBINAE sp. Yolk-sac 7.3.
ICTIOBINAE sp. Yolk-sac 7.4.
ICTIOBINAE sp. Yolk-sac 7.6.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.1.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.1.
ICTIOBINAE sp. Yolk-sac 7.3.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.4.
ICTIOBINAE sp. Yolk-sac 7.0.
ICTIOBINAE sp. Yolk-sac 7.4.
ICTIOBINAE sp. Yolk-sac 7.3.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.3.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.3.
ICTIOBINAE sp. Yolk-sac 7.0.
ICTIOBINAE sp. Yolk-sac. 93 ICTIOBINAE sp. Yolk-sac 8.7.
ICTIOBINAE sp. Yolk-sac 9.1.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 9.2.
ICTIOBINAE sp. Yolk-sac. 1 LOGPERCH type Yolk-sac 5.9.
LOGPERCH type Yolk-sac 6.6.
LOGPERCH type Yolk-sac 5.8.
LOGPERCH type Yolk-sac 6.2.
LOGPERCH type Yolk-sac 5.8.
LOGPERCH type Yolk-sac 6.0.
LOGPERCH type Yolk-sac 5.7.
LOGPERCH type Yolk-sac 5.8.
LOGPERCH type Yolk-sac 6.2.
LOGPERCH type Yolk-sac 6.2.
LOGPERCH type Yolk-sac 5.8.
LOGPERCH type Yolk-sac 5.7.
LOGPERCH type Yolk-sac 6.7.
LOGPERCH type Yolk-sac 6.2.
LOGPERCH type Yolk-sac 6.6.
LOGPERCH type Yolk-sac 6.1.
LOGPERCH type Yolk-sac 6.6.
LOGPERCH type Yolk-sac 5.8.
DARTER sp. Yolk-sac 8.0.
DARTER sp. Yolk-sac 7.2.
DARTER sp. Yolk-sac 7.2.
DARTER sp. Yolk-sac 6.5.
DARTER sp. Yolk-sac 6.3.
DARTER sp. Yolk-sac 6.7.
DARTER sp. Yolk-sac 8.2.
DARTER sp. Yolk-sac 8.9.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.0.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.5.
D-9 DRAFT
APPENDIX D (cont.)
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.6.
UNIDENTIFIED Egg 1.1.
UNIDENTIFIED Egg 1.2.
UNIDENTIFIED Egg 1.1.
UNIDENTIFIED Egg 1.1.
SAMPLE DATE: 13 May START DATE and TIME: 13MAY14:21:24 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.014510 STUDY GRAB TEMPERATURE (F): 67.5 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.1 FOREBAY CURRENT VELOCITY (ft/sec): 1.40 EXTRAPOLATION PERIOD: 11-17 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 10.7.
Dorosoma sp. Post Yolk-sac 5.2.
COMMON CARP Yolk-sac 6.9.
COMMON CARP Yolk-sac 6.2.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 6.0.
COMMON CARP Yolk-sac 6.4.
COMMON CARP Yolk-sac 7.6.
COMMON CARP Yolk-sac 6.0.
COMMON CARP Yolk-sac 6.7.
COMMON CARP Yolk-sac 6.7.
COMMON CARP Yolk-sac 6.3.
COMMON CARP Yolk-sac 7.2.
COMMON CARP Yolk-sac 6.4.
COMMON CARP Yolk-sac 6.9.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 6.8.
COMMON CARP Yolk-sac 6.4.
COMMON CARP Yolk-sac 7.7.
COMMON CARP Yolk-sac 6.2.
COMMON CARP Yolk-sac 6.4.
COMMON CARP Yolk-sac 6.7.
COMMON CARP Yolk-sac. 101 Semotilus type Yolk-sac 7.0.
Semotilus type Yolk-sac 9.7.
Semotilus type Yolk-sac 9.2.
Semotilus type Yolk-sac 9.2.
Semotilus type Yolk-sac 9.0.
Semotilus type Yolk-sac 9.4.
Semotilus type Yolk-sac 9.6.
Semotilus type Yolk-sac 8.7.
Semotilus type Yolk-sac 9.7.
Semotilus type Yolk-sac 8.8.
Semotilus type Yolk-sac 8.7.
Semotilus type Yolk-sac 7.5.
Semotilus type Yolk-sac 6.5.
Semotilus type Yolk-sac 6.6.
Semotilus type Yolk-sac 6.7.
Semotilus type Yolk-sac 6.6.
Semotilus type Yolk-sac 6.4.
Semotilus type Yolk-sac 8.7.
Semotilus type Yolk-sac 8.2.
Semotilus type Yolk-sac 7.9.
CYPRINIDAE sp. Yolk-sac 8.6.
CYPRINIDAE sp. Yolk-sac 8.5.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 5.8.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 7.2.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 5.1.
CYPRINIDAE sp. Yolk-sac 5.1.
CYPRINIDAE sp. Yolk-sac 5.1.
CYPRINIDAE sp. Yolk-sac 5.7.
Moxostoma sp. Yolk-sac 14.2.
Moxostoma sp. Yolk-sac 12.2.
Moxostoma sp. Yolk-sac 13.1.
Moxostoma sp. Yolk-sac 10.7.
ICTIOBINAE sp. Yolk-sac 8.9.
ICTIOBINAE sp. Yolk-sac 9.1.
ICTIOBINAE sp. Yolk-sac 9.2.
ICTIOBINAE sp. Yolk-sac 9.1.
ICTIOBINAE sp. Yolk-sac 9.1.
ICTIOBINAE sp. Yolk-sac 7.1.
ICTIOBINAE sp. Yolk-sac 7.7.
ICTIOBINAE sp. Yolk-sac 7.2.
D-10 DRAFT
APPENDIX D (cont.)
ICTIOBINAE sp. Yolk-sac 8.2.
ICTIOBINAE sp. Yolk-sac 7.4.
ICTIOBINAE sp. Yolk-sac 7.7.
ICTIOBINAE sp. Yolk-sac 7.3.
ICTIOBINAE sp. Yolk-sac 6.9.
ICTIOBINAE sp. Yolk-sac 7.7.
ICTIOBINAE sp. Yolk-sac 8.3.
ICTIOBINAE sp. Yolk-sac 7.4.
ICTIOBINAE sp. Yolk-sac 7.7.
ICTIOBINAE sp. Yolk-sac 8.1.
ICTIOBINAE sp. Yolk-sac 7.7.
ICTIOBINAE sp. Yolk-sac 7.5.
ICTIOBINAE sp. Yolk-sac. 191 ICTIOBINAE sp. Yolk-sac. 5 Sander sp. Yolk-sac 6.9.
Sander sp. Yolk-sac 6.7.
LOGPERCH type Yolk-sac 6.0.
LOGPERCH type Yolk-sac 6.3.
LOGPERCH type Yolk-sac 6.0.
LOGPERCH type Yolk-sac 6.1.
LOGPERCH type Yolk-sac 6.1.
LOGPERCH type Yolk-sac 6.4.
LOGPERCH type Yolk-sac 6.6.
LOGPERCH type Yolk-sac 6.5.
DARTER sp. Yolk-sac 7.0.
DARTER sp. Yolk-sac 6.6.
DARTER sp. Yolk-sac 9.2.
DARTER sp. Yolk-sac 9.2.
DARTER sp. Yolk-sac 9.2.
DARTER sp. Yolk-sac 5.9.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.7.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.8.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.5.
UNIDENTIFIED Larvae 2.6.
UNIDENTIFIED Egg 1.1.
UNIDENTIFIED Egg 1.2.
UNIDENTIFIED Egg 1.2.
UNIDENTIFIED Egg 1.4.
UNIDENTIFIED Egg 1.1.
SAMPLE DATE: 13 May START DATE and TIME: 13MAY14:21:04 SAMPLE DURATION (minutes): 22.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.013761 STUDY GRAB TEMPERATURE (F): 67.5 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.1 FOREBAY CURRENT VELOCITY (ft/sec): 1.40 EXTRAPOLATION PERIOD: 11-17 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 5.1.
Dorosoma sp. Post Yolk-sac 8.8.
COMMON CARP Yolk-sac 6.3.
COMMON CARP Yolk-sac 7.1.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 7.4.
COMMON CARP Yolk-sac 6.3.
COMMON CARP Yolk-sac 6.7.
COMMON CARP Yolk-sac 7.0.
COMMON CARP Yolk-sac 7.2.
COMMON CARP Yolk-sac 6.1.
COMMON CARP Yolk-sac 6.3.
COMMON CARP Yolk-sac 6.4.
COMMON CARP Yolk-sac 7.5.
COMMON CARP Yolk-sac 6.6.
COMMON CARP Yolk-sac 6.0.
COMMON CARP Yolk-sac 6.6.
COMMON CARP Yolk-sac 7.2.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 6.0.
COMMON CARP Yolk-sac 6.2.
COMMON CARP Yolk-sac 6.3.
COMMON CARP Yolk-sac. 51 D-11 DRAFT
APPENDIX D (cont.)
COMMON CARP Yolk-sac. 14 COMMON CARP Yolk-sac. 136 COMMON CARP Egg 1.6.
COMMON CARP Egg 1.7.
CYPRINIDAE sp. Yolk-sac 7.0.
CYPRINIDAE sp. Yolk-sac 6.7.
CYPRINIDAE sp. Yolk-sac 7.8.
CYPRINIDAE sp. Yolk-sac 8.6.
CYPRINIDAE sp. Yolk-sac 7.7.
CYPRINIDAE sp. Yolk-sac 8.2.
CYPRINIDAE sp. Yolk-sac 8.7.
CYPRINIDAE sp. Yolk-sac 8.6.
CYPRINIDAE sp. Yolk-sac 7.8.
CYPRINIDAE sp. Yolk-sac 8.1.
CYPRINIDAE sp. Yolk-sac 7.6.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 6.8.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 5.5.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 5.8.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 5.4.
CYPRINIDAE sp. Yolk-sac. 35 CYPRINIDAE sp. Yolk-sac. 4 Moxostoma sp. Yolk-sac 11.9.
Moxostoma sp. Yolk-sac 14.4.
Moxostoma sp. Yolk-sac 14.3.
ICTIOBINAE sp. Yolk-sac 9.7.
ICTIOBINAE sp. Yolk-sac 8.8.
ICTIOBINAE sp. Yolk-sac 8.7.
ICTIOBINAE sp. Yolk-sac 8.9.
ICTIOBINAE sp. Post Yolk-sac 9.5.
ICTIOBINAE sp. Post Yolk-sac 10.0.
ICTIOBINAE sp. Post Yolk-sac 8.6.
ICTIOBINAE sp. Yolk-sac 8.1.
ICTIOBINAE sp. Post Yolk-sac 9.7.
ICTIOBINAE sp. Post Yolk-sac 9.6.
ICTIOBINAE sp. Post Yolk-sac 8.7.
ICTIOBINAE sp. Post Yolk-sac 9.1.
ICTIOBINAE sp. Post Yolk-sac 9.2.
ICTIOBINAE sp. Post Yolk-sac 9.3.
ICTIOBINAE sp. Post Yolk-sac 8.7.
ICTIOBINAE sp. Post Yolk-sac 8.9.
ICTIOBINAE sp. Post Yolk-sac 8.2.
ICTIOBINAE sp. Post Yolk-sac 9.1.
ICTIOBINAE sp. Post Yolk-sac 8.7.
ICTIOBINAE sp. Post Yolk-sac 9.0.
ICTIOBINAE sp. Post Yolk-sac 8.8.
ICTIOBINAE sp. Post Yolk-sac 8.7.
ICTIOBINAE sp. Post Yolk-sac 8.4.
ICTIOBINAE sp. Yolk-sac. 146 ICTIOBINAE sp. Post Yolk-sac 13.6.
ICTIOBINAE sp. Yolk-sac. 446 ICTIOBINAE sp. Yolk-sac. 2 WALLEYE Post Yolk-sac 15.1.
Sander sp. Yolk-sac 7.2.
Sander sp. Yolk-sac 10.2.
Sander sp. Yolk-sac 9.9.
Sander sp. Yolk-sac 10.3.
Sander sp. Yolk-sac 9.5.
Sander sp. Yolk-sac 9.1.
LOGPERCH type Yolk-sac 5.8.
LOGPERCH type Yolk-sac 5.4.
LOGPERCH type Yolk-sac 5.6.
LOGPERCH type Yolk-sac 6.1.
LOGPERCH type Yolk-sac 6.2.
LOGPERCH type Yolk-sac 6.2.
LOGPERCH type Yolk-sac 6.7.
LOGPERCH type Yolk-sac 6.1.
LOGPERCH type Yolk-sac 5.9.
LOGPERCH type Yolk-sac 6.3.
LOGPERCH type Yolk-sac 6.2.
LOGPERCH type Yolk-sac 6.2.
LOGPERCH type Yolk-sac 6.0.
LOGPERCH type Yolk-sac 6.1.
LOGPERCH type Yolk-sac 6.3.
LOGPERCH type Yolk-sac 6.1.
LOGPERCH type Yolk-sac 5.7.
LOGPERCH type Yolk-sac 6.2.
LOGPERCH type Yolk-sac 6.4.
D-12 DRAFT
APPENDIX D (cont.)
LOGPERCH type Yolk-sac 5.7.
LOGPERCH type Yolk-sac. 14 LOGPERCH type Yolk-sac. 2 LOGPERCH type Yolk-sac. 9 DARTER sp. Yolk-sac 7.2.
DARTER sp. Yolk-sac 7.2.
DARTER sp. Yolk-sac 7.0.
DARTER sp. Yolk-sac 6.1.
DARTER sp. Yolk-sac 6.6.
DARTER sp. Yolk-sac 9.1.
DARTER sp. Yolk-sac 6.5.
DARTER sp. Yolk-sac 6.2.
DARTER sp. Yolk-sac 6.1.
DARTER sp. Yolk-sac 6.2.
DARTER sp. Yolk-sac 6.6.
DARTER sp. Yolk-sac 7.0.
DARTER sp. Yolk-sac 7.1.
DARTER sp. Yolk-sac 8.1.
DARTER sp. Yolk-sac 7.6.
DARTER sp. Yolk-sac 7.4.
DARTER sp. Yolk-sac 7.5.
DARTER sp. Yolk-sac 6.1.
DARTER sp. Yolk-sac 7.0.
DARTER sp. Yolk-sac 7.1.
DARTER sp. Yolk-sac 5.9.
DARTER sp. Yolk-sac 6.1.
FRESHWATER DRUM Egg 1.8.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.7.
FRESHWATER DRUM Egg 1.7.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.7.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.7.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.8.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.6.
UNIDENTIFIED Larvae. 1 UNIDENTIFIED Yolk-sac 7.1.
UNIDENTIFIED Yolk-sac. 3 UNIDENTIFIED Egg 1.1.
SAMPLE DATE: 13 May START DATE and TIME: 13MAY14:21:47 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.016856 STUDY GRAB TEMPERATURE (F): 67.3 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.1 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 11-17 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 6.8.
COMMON CARP Yolk-sac 6.7.
COMMON CARP Yolk-sac 6.9.
COMMON CARP Yolk-sac 6.6.
COMMON CARP Yolk-sac 6.7.
COMMON CARP Yolk-sac 6.7.
COMMON CARP Yolk-sac 7.2.
COMMON CARP Yolk-sac 7.1.
COMMON CARP Yolk-sac 7.0.
COMMON CARP Yolk-sac 7.2.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 6.2.
COMMON CARP Yolk-sac 6.1.
COMMON CARP Yolk-sac 7.0.
COMMON CARP Yolk-sac 7.0.
COMMON CARP Yolk-sac 6.7.
COMMON CARP Yolk-sac 6.8.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 6.6.
COMMON CARP Yolk-sac. 108 COMMON CARP Egg 1.5.
CYPRINIDAE sp. Yolk-sac 5.6.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 5.4.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 6.3.
D-13 DRAFT
APPENDIX D (cont.)
CYPRINIDAE sp. Yolk-sac 5.6.
CYPRINIDAE sp. Yolk-sac 6.7.
CYPRINIDAE sp. Yolk-sac 6.2.
Moxostoma sp. Post Yolk-sac 14.7.
Moxostoma sp. Yolk-sac 13.3.
ICTIOBINAE sp. Yolk-sac 7.5.
ICTIOBINAE sp. Yolk-sac 7.4.
ICTIOBINAE sp. Yolk-sac 7.5.
ICTIOBINAE sp. Yolk-sac 6.9.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.7.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.4.
ICTIOBINAE sp. Yolk-sac 7.0.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.4.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.5.
ICTIOBINAE sp. Yolk-sac 7.7.
ICTIOBINAE sp. Yolk-sac 7.0.
ICTIOBINAE sp. Yolk-sac 7.6.
ICTIOBINAE sp. Yolk-sac 7.9.
ICTIOBINAE sp. Yolk-sac 8.6.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.1.
ICTIOBINAE sp. Yolk-sac. 154 LOGPERCH type Yolk-sac 6.5.
LOGPERCH type Yolk-sac 6.2.
LOGPERCH type Yolk-sac 6.0.
LOGPERCH type Yolk-sac 6.1.
LOGPERCH type Yolk-sac 5.5.
DARTER sp. Yolk-sac 6.1.
DARTER sp. Yolk-sac 6.3.
DARTER sp. Yolk-sac 9.9.
DARTER sp. Yolk-sac 7.9.
DARTER sp. Yolk-sac 8.2.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.7.
UNIDENTIFIED Egg 1.7.
UNIDENTIFIED Egg 1.6.
UNIDENTIFIED Egg 1.6.
UNIDENTIFIED Egg 1.5.
UNIDENTIFIED Egg 1.6.
UNIDENTIFIED Egg 1.5.
UNIDENTIFIED Egg 1.4.
UNIDENTIFIED Egg 1.3.
UNIDENTIFIED Egg 1.6.
UNIDENTIFIED Egg 1.6.
UNIDENTIFIED Egg 1.6.
UNIDENTIFIED Egg 1.4.
UNIDENTIFIED Egg 1.5.
SAMPLE DATE: 13 May START DATE and TIME: 13MAY14:21:42 SAMPLE DURATION (minutes): 18.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.016505 STUDY GRAB TEMPERATURE (F): 67.3 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.1 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 11-17 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 6.1.
Dorosoma sp. Post Yolk-sac 11.0.
COMMON CARP Yolk-sac 6.6.
COMMON CARP Yolk-sac 6.7.
COMMON CARP Yolk-sac 6.1.
COMMON CARP Yolk-sac 6.7.
COMMON CARP Yolk-sac 6.2.
COMMON CARP Yolk-sac 6.6.
COMMON CARP Yolk-sac 6.4.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 6.0.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 6.3.
COMMON CARP Yolk-sac 6.7.
COMMON CARP Yolk-sac 6.4.
COMMON CARP Yolk-sac 5.7.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 6.2.
COMMON CARP Yolk-sac 6.2.
COMMON CARP Yolk-sac 6.2.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 6.2.
COMMON CARP Egg 1.7.
COMMON CARP Egg 1.6.
COMMON CARP Egg 1.5.
D-14 DRAFT
APPENDIX D (cont.)
COMMON CARP Egg 1.6.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 5.1.
CYPRINIDAE sp. Yolk-sac 5.4.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 5.8.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 5.4.
CYPRINIDAE sp. Yolk-sac 6.1.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 5.5.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 5.6.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac. 22 Moxostoma sp. Yolk-sac 13.3.
Moxostoma sp. Yolk-sac 12.9.
ICTIOBINAE sp. Post Yolk-sac 13.7.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 6.9.
ICTIOBINAE sp. Yolk-sac 7.4.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.3.
ICTIOBINAE sp. Yolk-sac 7.5.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.1.
ICTIOBINAE sp. Yolk-sac 7.0.
ICTIOBINAE sp. Yolk-sac 6.9.
ICTIOBINAE sp. Yolk-sac 7.0.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 6.8.
ICTIOBINAE sp. Yolk-sac 7.3.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.1.
PUMPKINSEED type Yolk-sac 4.3.
PUMPKINSEED type Yolk-sac 6.3.
PUMPKINSEED type Yolk-sac 4.7.
Sander sp. Yolk-sac 9.1.
LOGPERCH type Yolk-sac 6.7.
LOGPERCH type Yolk-sac 6.0.
LOGPERCH type Yolk-sac 6.0.
LOGPERCH type Yolk-sac 6.2.
LOGPERCH type Yolk-sac 5.8.
LOGPERCH type Yolk-sac 6.1.
LOGPERCH type Yolk-sac 6.8.
LOGPERCH type Yolk-sac 6.4.
LOGPERCH type Yolk-sac 6.6.
LOGPERCH type Yolk-sac 6.5.
LOGPERCH type Yolk-sac 6.1.
LOGPERCH type Yolk-sac 6.2.
LOGPERCH type Yolk-sac 6.4.
DARTER sp. Yolk-sac 6.2.
DARTER sp. Yolk-sac 6.0.
DARTER sp. Yolk-sac 5.9.
DARTER sp. Yolk-sac 5.0.
DARTER sp. Yolk-sac 5.1.
DARTER sp. Yolk-sac 5.7.
DARTER sp. Yolk-sac 10.2.
DARTER sp. Yolk-sac 6.0.
DARTER sp. Yolk-sac 6.2.
DARTER sp. Yolk-sac 5.2.
DARTER sp. Yolk-sac 6.0.
DARTER sp. Yolk-sac 6.1.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.4.
UNIDENTIFIED Yolk-sac 5.8.
D-15 DRAFT
APPENDIX D (cont.)
UNIDENTIFIED Yolk-sac 5.5.
UNIDENTIFIED Yolk-sac 5.5.
UNIDENTIFIED Egg 1.1.
UNIDENTIFIED Egg 1.0.
UNIDENTIFIED Egg 1.1.
UNIDENTIFIED Egg 1.0.
SAMPLE DATE: 20 May START DATE and TIME: 20MAY14:17:18 SAMPLE DURATION (minutes): 17.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.016534 STUDY GRAB TEMPERATURE (F): 62.6 STUDY GRAB DISSOLVED OXYGEN (mg/L): 10.4 FOREBAY CURRENT VELOCITY (ft/sec): 0.96 EXTRAPOLATION PERIOD: 18-24 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Semotilus type Yolk-sac 7.7.
CYPRINIDAE sp. Yolk-sac 7.1.
CYPRINIDAE sp. Yolk-sac 6.7.
CYPRINIDAE sp. Yolk-sac 6.5.
Moxostoma sp. Yolk-sac 13.5.
ICTIOBINAE sp. Yolk-sac 8.2.
ICTIOBINAE sp. Yolk-sac 8.2.
ICTIOBINAE sp. Yolk-sac 7.8.
ICTIOBINAE sp. Yolk-sac 8.8.
ICTIOBINAE sp. Yolk-sac 8.7.
ICTIOBINAE sp. Yolk-sac 8.2.
LOGPERCH type Yolk-sac 6.1.
LOGPERCH type Yolk-sac 6.0.
LOGPERCH type Yolk-sac 6.1.
DARTER sp. Yolk-sac 6.4.
DARTER sp. Yolk-sac 9.4.
DARTER sp. Yolk-sac 8.0.
Morone/Pomoxis type Egg 0.8.
Morone/Pomoxis type Egg 0.8.
SAMPLE DATE: 20 May START DATE and TIME: 20MAY14:17:18 SAMPLE DURATION (minutes): 17.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.016931 STUDY GRAB TEMPERATURE (F): 62.6 STUDY GRAB DISSOLVED OXYGEN (mg/L): 10.4 FOREBAY CURRENT VELOCITY (ft/sec): 0.96 EXTRAPOLATION PERIOD: 18-24 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT COMMON CARP Egg 1.7.
CYPRINIDAE sp. Yolk-sac 5.8.
ICTIOBINAE sp. Yolk-sac 7.1.
SAMPLE DATE: 20 May START DATE and TIME: 20MAY14:17:58 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.015820 STUDY GRAB TEMPERATURE (F): 62.4 STUDY GRAB DISSOLVED OXYGEN (mg/L): 9.8 FOREBAY CURRENT VELOCITY (ft/sec): 1.34 EXTRAPOLATION PERIOD: 18-24 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT ICTIOBINAE sp. Yolk-sac 6.8.
ICTIOBINAE sp. Yolk-sac 6.8.
ICTIOBINAE sp. Yolk-sac 9.0.
ICTIOBINAE sp. Yolk-sac 9.1.
ICTIOBINAE sp. Yolk-sac 8.7.
LOGPERCH type Yolk-sac 6.2.
LOGPERCH type Yolk-sac 5.9.
LOGPERCH type Yolk-sac 6.4.
SAMPLE DATE: 20 May START DATE and TIME: 20MAY14:17:58 SAMPLE DURATION (minutes): 23.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.018595 STUDY GRAB TEMPERATURE (F): 62.4 STUDY GRAB DISSOLVED OXYGEN (mg/L): 9.8 FOREBAY CURRENT VELOCITY (ft/sec): 1.34 EXTRAPOLATION PERIOD: 18-24 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT ICTIOBINAE sp. Yolk-sac 7.0.
ICTIOBINAE sp. Yolk-sac 8.3.
DARTER sp. Yolk-sac 7.8.
FRESHWATER DRUM Egg 1.8.
SAMPLE DATE: 20 May START DATE and TIME: 20MAY14:21:11 SAMPLE DURATION (minutes): 16.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.016802 STUDY GRAB TEMPERATURE (F): 62.1 STUDY GRAB DISSOLVED OXYGEN (mg/L): 9.5 FOREBAY CURRENT VELOCITY (ft/sec): 1.30 EXTRAPOLATION PERIOD: 18-24 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Semotilus type Yolk-sac 10.0.
Semotilus type Yolk-sac 9.2.
D-16 DRAFT
APPENDIX D (cont.)
Semotilus type Yolk-sac 8.8.
Semotilus type Yolk-sac 9.7.
CYPRINIDAE sp. Yolk-sac 5.8.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 6.6.
CYPRINIDAE sp. Yolk-sac 7.0.
CYPRINIDAE sp. Yolk-sac 7.5.
CYPRINIDAE sp. Yolk-sac 7.4.
Moxostoma sp. Yolk-sac 13.1.
Moxostoma sp. Yolk-sac 13.4.
Moxostoma sp. Yolk-sac 13.3.
Moxostoma sp. Yolk-sac 13.9.
Moxostoma sp. Yolk-sac 13.9.
Moxostoma sp. Post Yolk-sac 14.8.
Moxostoma sp. Post Yolk-sac 14.8.
Moxostoma sp. Yolk-sac 14.1.
Moxostoma sp. Yolk-sac 14.2.
Moxostoma sp. Yolk-sac 14.1.
Moxostoma sp. Yolk-sac 13.8.
Moxostoma sp. Yolk-sac 13.4.
ICTIOBINAE sp. Yolk-sac 7.5.
ICTIOBINAE sp. Yolk-sac 7.7.
ICTIOBINAE sp. Yolk-sac 7.7.
ICTIOBINAE sp. Yolk-sac 8.3.
ICTIOBINAE sp. Yolk-sac 7.4.
ICTIOBINAE sp. Post Yolk-sac 10.1.
ICTIOBINAE sp. Yolk-sac 8.2.
ICTIOBINAE sp. Yolk-sac 8.1.
ICTIOBINAE sp. Yolk-sac 8.2.
ICTIOBINAE sp. Yolk-sac 9.0.
ICTIOBINAE sp. Yolk-sac 6.8.
ICTIOBINAE sp. Yolk-sac 9.4.
ICTIOBINAE sp. Yolk-sac 8.6.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 8.9.
ICTIOBINAE sp. Yolk-sac 6.7.
ICTIOBINAE sp. Yolk-sac 6.8.
ICTIOBINAE sp. Yolk-sac 8.2.
ICTIOBINAE sp. Yolk-sac 7.7.
ICTIOBINAE sp. Post Yolk-sac 10.6.
ICTIOBINAE sp. Post Yolk-sac 9.9.
ICTIOBINAE sp. Post Yolk-sac 9.4.
ICTIOBINAE sp. Post Yolk-sac 10.6.
ICTIOBINAE sp. Yolk-sac 8.2.
ICTIOBINAE sp. Yolk-sac 8.7.
ICTIOBINAE sp. Yolk-sac 8.4.
ICTIOBINAE sp. Yolk-sac 8.3.
ICTIOBINAE sp. Yolk-sac. 2 ICTIOBINAE sp. Post Yolk-sac. 5 LOGPERCH type Yolk-sac 6.2.
LOGPERCH type Yolk-sac 6.3.
LOGPERCH type Yolk-sac 7.0.
LOGPERCH type Yolk-sac 6.3.
LOGPERCH type Yolk-sac 7.0.
DARTER sp. Yolk-sac 9.4.
DARTER sp. Yolk-sac 10.2.
DARTER sp. Yolk-sac 10.2.
DARTER sp. Yolk-sac 6.7.
DARTER sp. Yolk-sac 7.2.
DARTER sp. Yolk-sac 9.4.
DARTER sp. Yolk-sac 8.9.
DARTER sp. Yolk-sac 7.0.
DARTER sp. Yolk-sac 7.7.
DARTER sp. Yolk-sac 7.8.
DARTER sp. Yolk-sac 7.8.
DARTER sp. Yolk-sac 8.2.
Morone/Pomoxis type Egg 0.7.
SAMPLE DATE: 20 May START DATE and TIME: 20MAY14:21:11 SAMPLE DURATION (minutes): 16.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.020249 STUDY GRAB TEMPERATURE (F): 62.1 STUDY GRAB DISSOLVED OXYGEN (mg/L): 9.5 FOREBAY CURRENT VELOCITY (ft/sec): 1.30 EXTRAPOLATION PERIOD: 18-24 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT COMMON CARP Yolk-sac 6.7.
COMMON CARP Post Yolk-sac 13.8.
Semotilus type Post Yolk-sac 12.7.
Semotilus type Post Yolk-sac 10.1.
CYPRINIDAE sp. Yolk-sac 7.6.
CYPRINIDAE sp. Yolk-sac 7.3.
CYPRINIDAE sp. Yolk-sac 6.8.
Moxostoma sp. Yolk-sac 13.4.
ICTIOBINAE sp. Yolk-sac 10.0.
ICTIOBINAE sp. Yolk-sac 10.0.
ICTIOBINAE sp. Yolk-sac 10.1.
D-17 DRAFT
APPENDIX D (cont.)
ICTIOBINAE sp. Post Yolk-sac 10.5.
ICTIOBINAE sp. Yolk-sac 7.5.
ICTIOBINAE sp. Post Yolk-sac 10.4.
ICTIOBINAE sp. Post Yolk-sac 10.4.
ICTIOBINAE sp. Post Yolk-sac 10.3.
ICTIOBINAE sp. Yolk-sac. 2 LOGPERCH type Yolk-sac 6.8.
SAMPLE DATE: 20 May START DATE and TIME: 20MAY14:21:42 SAMPLE DURATION (minutes): 16.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.021624 STUDY GRAB TEMPERATURE (F): 61.9 STUDY GRAB DISSOLVED OXYGEN (mg/L): 10.0 FOREBAY CURRENT VELOCITY (ft/sec): 1.40 EXTRAPOLATION PERIOD: 18-24 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT COMMON CARP Yolk-sac 7.1.
Semotilus type Post Yolk-sac 9.8.
Semotilus type Post Yolk-sac 9.0.
Semotilus type Post Yolk-sac 7.9.
Semotilus type Post Yolk-sac 7.9.
Semotilus type Post Yolk-sac 10.9.
CYPRINIDAE sp. Yolk-sac 6.5.
Moxostoma sp. Yolk-sac 14.1.
Moxostoma sp. Yolk-sac 14.2.
Moxostoma sp. Yolk-sac 13.8.
ICTIOBINAE sp. Yolk-sac 6.2.
ICTIOBINAE sp. Yolk-sac 7.6.
ICTIOBINAE sp. Post Yolk-sac 9.6.
ICTIOBINAE sp. Post Yolk-sac 10.0.
ICTIOBINAE sp. Yolk-sac 8.7.
ICTIOBINAE sp. Yolk-sac 7.9.
ICTIOBINAE sp. Yolk-sac 8.5.
ICTIOBINAE sp. Yolk-sac 6.7.
ICTIOBINAE sp. Post Yolk-sac 10.1.
ICTIOBINAE sp. Post Yolk-sac 10.4.
ICTIOBINAE sp. Yolk-sac 8.7.
ICTIOBINAE sp. Post Yolk-sac 9.5.
ICTIOBINAE sp. Post Yolk-sac 10.2.
ICTIOBINAE sp. Yolk-sac 8.0.
ICTIOBINAE sp. Yolk-sac 8.7.
ICTIOBINAE sp. Yolk-sac 7.7.
ICTIOBINAE sp. Yolk-sac 7.5.
ICTIOBINAE sp. Yolk-sac 7.6.
ICTIOBINAE sp. Yolk-sac 8.1.
LOGPERCH type Yolk-sac 7.0.
DARTER sp. Yolk-sac 7.2.
DARTER sp. Yolk-sac 7.8.
DARTER sp. Yolk-sac 9.1.
DARTER sp. Yolk-sac 10.2.
DARTER sp. Yolk-sac 8.7.
SAMPLE DATE: 20 May START DATE and TIME: 20MAY14:21:42 SAMPLE DURATION (minutes): 23.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.015906 STUDY GRAB TEMPERATURE (F): 61.9 STUDY GRAB DISSOLVED OXYGEN (mg/L): 10.0 FOREBAY CURRENT VELOCITY (ft/sec): 1.40 EXTRAPOLATION PERIOD: 18-24 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT COMMON CARP Egg 1.9.
Moxostoma sp. Yolk-sac 12.2.
Moxostoma sp. Yolk-sac 12.7.
ICTIOBINAE sp. Yolk-sac 8.2.
ICTIOBINAE sp. Yolk-sac 8.0.
ICTIOBINAE sp. Yolk-sac 7.1.
ICTIOBINAE sp. Post Yolk-sac 9.9.
ICTIOBINAE sp. Post Yolk-sac 11.0.
ICTIOBINAE sp. Post Yolk-sac 10.2.
DARTER sp. Post Yolk-sac 10.2.
SAMPLE DATE: 28 May START DATE and TIME: 28MAY14:18:55 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.015019 STUDY GRAB TEMPERATURE (F): 75.2 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.5 FOREBAY CURRENT VELOCITY (ft/sec): 1.70 EXTRAPOLATION PERIOD: 25-31 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 6.2.
Dorosoma sp. Post Yolk-sac 5.1.
COMMON CARP Yolk-sac 6.7.
COMMON CARP Yolk-sac 6.9.
COMMON CARP Yolk-sac 5.7.
COMMON CARP Yolk-sac 6.8.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 1.9.
D-18 DRAFT
APPENDIX D (cont.)
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 2.0.
CYPRINIDAE sp. Yolk-sac 2.2.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 1.6.
CYPRINIDAE sp. Yolk-sac 2.1.
CYPRINIDAE sp. Yolk-sac 2.2.
CYPRINIDAE sp. Yolk-sac 1.9.
CYPRINIDAE sp. Yolk-sac 2.4.
CYPRINIDAE sp. Yolk-sac 2.5.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 1.3.
CYPRINIDAE sp. Yolk-sac 1.8.
CYPRINIDAE sp. Yolk-sac 1.2.
CYPRINIDAE sp. Yolk-sac 1.2.
CYPRINIDAE sp. Yolk-sac 1.8.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac. 5 CYPRINIDAE sp. Egg 2.0.
CYPRINIDAE sp. Egg 1.8.
CYPRINIDAE sp. Egg 1.8.
ICTIOBINAE sp. Yolk-sac 7.0.
ICTIOBINAE sp. Yolk-sac 7.7.
ICTIOBINAE sp. Yolk-sac 7.5.
ICTIOBINAE sp. Yolk-sac 7.8.
ICTIOBINAE sp. Yolk-sac 7.4.
ICTIOBINAE sp. Yolk-sac 7.4.
LOGPERCH type Yolk-sac 5.8.
LOGPERCH type Post Yolk-sac 9.8.
LOGPERCH type Post Yolk-sac 10.2.
DARTER sp. Yolk-sac 7.1.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.7.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.4.
SAMPLE DATE: 28 May START DATE and TIME: 28MAY14:18:55 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.014093 STUDY GRAB TEMPERATURE (F): 75.2 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.5 FOREBAY CURRENT VELOCITY (ft/sec): 1.70 EXTRAPOLATION PERIOD: 25-31 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT COMMON CARP Yolk-sac 7.7.
COMMON CARP Yolk-sac 6.6.
COMMON CARP Yolk-sac 7.0.
COMMON CARP Yolk-sac 7.2.
CYPRINIDAE sp. Yolk-sac 1.2.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 1.8.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 2.0.
CYPRINIDAE sp. Egg 1.1.
CYPRINIDAE sp. Egg 1.4.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 2.2.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 2.1.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Egg 1.5.
CYPRINIDAE sp. Egg 1.7.
CYPRINIDAE sp. Egg 1.6.
CYPRINIDAE sp. Egg 1.7.
CYPRINIDAE sp. Egg 1.8.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 1.8.
CYPRINIDAE sp. Yolk-sac 1.2.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac. 7 ICTIOBINAE sp. Yolk-sac 6.5.
ICTIOBINAE sp. Yolk-sac 7.6.
ICTIOBINAE sp. Yolk-sac 8.0.
ICTIOBINAE sp. Yolk-sac 7.9.
D-19 DRAFT
APPENDIX D (cont.)
ICTIOBINAE sp. Yolk-sac 8.6.
ICTIOBINAE sp. Yolk-sac 7.4.
DARTER sp. Yolk-sac 6.2.
FRESHWATER DRUM Egg 1.7.
FRESHWATER DRUM Egg 2.0.
FRESHWATER DRUM Egg 1.7.
SAMPLE DATE: 28 May START DATE and TIME: 28MAY14:19:19 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.014447 STUDY GRAB TEMPERATURE (F): 75.2 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.5 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 25-31 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 10.3.
Dorosoma sp. Post Yolk-sac 10.0.
Dorosoma sp. Post Yolk-sac 7.7.
Dorosoma sp. Post Yolk-sac 7.4.
COMMON CARP Yolk-sac 6.3.
COMMON CARP Yolk-sac 7.0.
COMMON CARP Yolk-sac 7.0.
COMMON CARP Yolk-sac 6.9.
COMMON CARP Yolk-sac 6.6.
COMMON CARP Yolk-sac 6.7.
COMMON CARP Yolk-sac 7.7.
CYPRINIDAE sp. Yolk-sac 2.3.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 1.6.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 1.3.
CYPRINIDAE sp. Egg 1.3.
CYPRINIDAE sp. Egg 1.6.
CYPRINIDAE sp. Egg 1.3.
CYPRINIDAE sp. Egg 1.7.
CYPRINIDAE sp. Yolk-sac 1.6.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 1.3.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 2.1.
CYPRINIDAE sp. Yolk-sac 2.2.
CYPRINIDAE sp. Yolk-sac 2.0.
CYPRINIDAE sp. Yolk-sac 1.6.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac. 8 ICTIOBINAE sp. Yolk-sac 7.4.
ICTIOBINAE sp. Yolk-sac 7.7.
ICTIOBINAE sp. Yolk-sac 7.6.
ICTIOBINAE sp. Yolk-sac 7.1.
ICTIOBINAE sp. Yolk-sac 7.4.
ICTIOBINAE sp. Yolk-sac 6.8.
ICTIOBINAE sp. Yolk-sac 7.0.
ICTIOBINAE sp. Yolk-sac 7.6.
ICTIOBINAE sp. Yolk-sac 8.0.
ICTIOBINAE sp. Yolk-sac 7.9.
ICTIOBINAE sp. Yolk-sac 7.5.
ICTIOBINAE sp. Yolk-sac 6.4.
Morone sp. Yolk-sac 2.7.
FRESHWATER DRUM Egg 1.1.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.4.
SAMPLE DATE: 28 May START DATE and TIME: 28MAY14:19:19 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.013676 STUDY GRAB TEMPERATURE (F): 75.2 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.5 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 25-31 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 10.2.
Dorosoma sp. Post Yolk-sac 5.8.
Dorosoma sp. Post Yolk-sac 8.1.
Dorosoma sp. Post Yolk-sac 5.0.
Dorosoma sp. Post Yolk-sac 5.0.
COMMON CARP Yolk-sac 7.1.
COMMON CARP Yolk-sac 6.9.
COMMON CARP Yolk-sac 7.0.
COMMON CARP Yolk-sac 7.1.
COMMON CARP Post Yolk-sac 9.3.
CYPRINIDAE sp. Yolk-sac 5.5.
D-20 DRAFT
APPENDIX D (cont.)
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Egg 1.7.
CYPRINIDAE sp. Egg 1.8.
CYPRINIDAE sp. Egg 1.7.
CYPRINIDAE sp. Egg 1.5.
CYPRINIDAE sp. Egg 1.6.
CYPRINIDAE sp. Egg 1.6.
CYPRINIDAE sp. Egg 1.8.
CYPRINIDAE sp. Egg 1.7.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 1.3.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 1.2.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 2.0.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 1.6.
CYPRINIDAE sp. Yolk-sac 1.2.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 2.1.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 1.8.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac. 10 ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 6.7.
ICTIOBINAE sp. Yolk-sac 7.1.
ICTIOBINAE sp. Yolk-sac 7.0.
ICTIOBINAE sp. Yolk-sac 7.0.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.1.
ICTIOBINAE sp. Yolk-sac 7.5.
ICTIOBINAE sp. Yolk-sac 7.7.
ICTIOBINAE sp. Yolk-sac 7.0.
ICTIOBINAE sp. Yolk-sac 6.7.
ICTIOBINAE sp. Yolk-sac 6.8.
ICTIOBINAE sp. Yolk-sac 7.3.
ICTIOBINAE sp. Yolk-sac 7.0.
ICTIOBINAE sp. Yolk-sac 7.3.
ICTIOBINAE sp. Yolk-sac 6.6.
LOGPERCH type Yolk-sac 4.0.
LOGPERCH type Yolk-sac 5.9.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
SAMPLE DATE: 28 May START DATE and TIME: 28MAY14:21:19 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.013593 STUDY GRAB TEMPERATURE (F): 74.8 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.7 FOREBAY CURRENT VELOCITY (ft/sec): 1.70 EXTRAPOLATION PERIOD: 25-31 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 10.1.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 6.4.
COMMON CARP Yolk-sac 6.9.
COMMON CARP Yolk-sac 6.9.
COMMON CARP Yolk-sac 6.9.
COMMON CARP Yolk-sac 7.2.
COMMON CARP Yolk-sac 7.0.
COMMON CARP Yolk-sac 7.1.
COMMON CARP Yolk-sac 7.2.
COMMON CARP Yolk-sac 6.8.
COMMON CARP Yolk-sac 7.0.
COMMON CARP Yolk-sac 7.4.
COMMON CARP Yolk-sac 6.6.
COMMON CARP Yolk-sac 7.0.
COMMON CARP Yolk-sac 7.2.
COMMON CARP Yolk-sac 6.7.
COMMON CARP Yolk-sac 7.2.
COMMON CARP Yolk-sac 6.7.
COMMON CARP Yolk-sac 7.2.
COMMON CARP Yolk-sac 6.8.
COMMON CARP Yolk-sac. 6 CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 1.9.
CYPRINIDAE sp. Yolk-sac 2.1.
CYPRINIDAE sp. Yolk-sac 1.8.
D-21 DRAFT
APPENDIX D (cont.)
Moxostoma sp. Post Yolk-sac 14.1.
Moxostoma sp. Post Yolk-sac 14.7.
ICTIOBINAE sp. Yolk-sac 6.2.
ICTIOBINAE sp. Yolk-sac 6.5.
ICTIOBINAE sp. Yolk-sac 6.6.
ICTIOBINAE sp. Yolk-sac 8.1.
ICTIOBINAE sp. Yolk-sac 6.3.
ICTIOBINAE sp. Yolk-sac 6.6.
ICTIOBINAE sp. Yolk-sac 7.9.
ICTIOBINAE sp. Yolk-sac 7.1.
ICTIOBINAE sp. Yolk-sac 6.9.
ICTIOBINAE sp. Yolk-sac 6.6.
ICTIOBINAE sp. Yolk-sac 7.9.
ICTIOBINAE sp. Yolk-sac 7.8.
ICTIOBINAE sp. Yolk-sac 7.0.
ICTIOBINAE sp. Yolk-sac 6.9.
ICTIOBINAE sp. Yolk-sac 8.2.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 6.6.
ICTIOBINAE sp. Yolk-sac 8.2.
ICTIOBINAE sp. Yolk-sac 6.7.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac. 24 LOGPERCH type Yolk-sac 5.9.
DARTER sp. Yolk-sac 8.7.
DARTER sp. Yolk-sac 4.9.
DARTER sp. Yolk-sac 5.3.
FRESHWATER DRUM Egg 1.7.
FRESHWATER DRUM Egg 1.5.
ROUND GOBY Juvenile 7.2.
ROUND GOBY Juvenile 8.2.
ROUND GOBY Juvenile 7.1.
ROUND GOBY Juvenile 7.4.
ROUND GOBY Juvenile 7.5.
ROUND GOBY Juvenile 7.4.
ROUND GOBY Juvenile 7.2.
ROUND GOBY Juvenile 7.7.
ROUND GOBY Juvenile 7.1.
ROUND GOBY Juvenile 8.7.
ROUND GOBY Juvenile 7.5.
ROUND GOBY Juvenile 7.0.
SAMPLE DATE: 28 May START DATE and TIME: 28MAY14:21:19 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.013655 STUDY GRAB TEMPERATURE (F): 74.8 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.7 FOREBAY CURRENT VELOCITY (ft/sec): 1.70 EXTRAPOLATION PERIOD: 25-31 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 7.7.
COMMON CARP Yolk-sac 6.7.
COMMON CARP Yolk-sac 7.2.
COMMON CARP Yolk-sac 7.4.
COMMON CARP Yolk-sac 7.6.
COMMON CARP Yolk-sac 6.8.
COMMON CARP Yolk-sac 6.9.
COMMON CARP Yolk-sac 6.4.
COMMON CARP Yolk-sac 7.9.
COMMON CARP Yolk-sac 6.4.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 6.6.
COMMON CARP Yolk-sac 7.2.
COMMON CARP Yolk-sac 6.7.
COMMON CARP Yolk-sac 8.0.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 1.8.
CYPRINIDAE sp. Yolk-sac 2.6.
CYPRINIDAE sp. Yolk-sac 2.7.
CYPRINIDAE sp. Yolk-sac 2.1.
CYPRINIDAE sp. Yolk-sac 1.2.
ICTIOBINAE sp. Yolk-sac 6.3.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 6.7.
ICTIOBINAE sp. Yolk-sac 7.3.
ICTIOBINAE sp. Yolk-sac 6.2.
ICTIOBINAE sp. Yolk-sac 7.0.
ICTIOBINAE sp. Yolk-sac 6.3.
ICTIOBINAE sp. Yolk-sac 7.6.
ICTIOBINAE sp. Yolk-sac 7.4.
ICTIOBINAE sp. Yolk-sac 7.6.
ICTIOBINAE sp. Yolk-sac 7.0.
ICTIOBINAE sp. Yolk-sac 7.1.
ICTIOBINAE sp. Yolk-sac 7.7.
D-22 DRAFT
APPENDIX D (cont.)
ICTIOBINAE sp. Yolk-sac 6.6.
ICTIOBINAE sp. Yolk-sac 6.7.
ICTIOBINAE sp. Yolk-sac 6.3.
ICTIOBINAE sp. Yolk-sac 6.8.
ICTIOBINAE sp. Yolk-sac 7.9.
ICTIOBINAE sp. Yolk-sac 6.7.
ICTIOBINAE sp. Yolk-sac 6.7.
ICTIOBINAE sp. Yolk-sac. 13 PUMPKINSEED type Yolk-sac 4.5.
LOGPERCH type Yolk-sac 6.4.
ROUND GOBY Juvenile 7.0.
ROUND GOBY Juvenile 7.8.
ROUND GOBY Juvenile 7.1.
ROUND GOBY Juvenile 7.5.
ROUND GOBY Juvenile 7.6.
ROUND GOBY Juvenile 7.2.
ROUND GOBY Juvenile 7.5.
ROUND GOBY Juvenile 7.1.
ROUND GOBY Juvenile 7.3.
Morone/Pomoxis type Egg 0.9.
Morone/Pomoxis type Egg 1.1.
Morone/Pomoxis type Egg 1.0.
Morone/Pomoxis type Egg 0.9.
Morone/Pomoxis type Egg 1.1.
SAMPLE DATE: 28 May START DATE and TIME: 28MAY14:21:44 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.015853 STUDY GRAB TEMPERATURE (F): 75.0 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.8 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 25-31 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 7.2.
Dorosoma sp. Post Yolk-sac 9.0.
Dorosoma sp. Post Yolk-sac 9.1.
COMMON CARP Yolk-sac 7.1.
COMMON CARP Yolk-sac 7.2.
COMMON CARP Yolk-sac 6.6.
COMMON CARP Yolk-sac 7.5.
COMMON CARP Yolk-sac 6.9.
COMMON CARP Yolk-sac 6.4.
COMMON CARP Yolk-sac 6.7.
COMMON CARP Yolk-sac 7.5.
COMMON CARP Yolk-sac 7.0.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 7.1.
COMMON CARP Yolk-sac 6.6.
COMMON CARP Yolk-sac 7.8.
COMMON CARP Yolk-sac 7.5.
COMMON CARP Yolk-sac 7.4.
COMMON CARP Yolk-sac 7.7.
COMMON CARP Yolk-sac 7.2.
COMMON CARP Yolk-sac 7.6.
COMMON CARP Yolk-sac 7.7.
COMMON CARP Yolk-sac 7.5.
COMMON CARP Yolk-sac. 9 COMMON CARP Yolk-sac. 2 CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 2.0.
CYPRINIDAE sp. Yolk-sac 2.1.
CYPRINIDAE sp. Yolk-sac 2.0.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 1.8.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 3.0.
CYPRINIDAE sp. Yolk-sac 2.6.
CYPRINIDAE sp. Yolk-sac 2.7.
CYPRINIDAE sp. Yolk-sac 1.6.
ICTIOBINAE sp. Yolk-sac 7.5.
ICTIOBINAE sp. Yolk-sac 6.3.
ICTIOBINAE sp. Yolk-sac 7.4.
ICTIOBINAE sp. Yolk-sac 7.6.
ICTIOBINAE sp. Yolk-sac 7.0.
ICTIOBINAE sp. Yolk-sac 7.1.
ICTIOBINAE sp. Yolk-sac 7.4.
ICTIOBINAE sp. Yolk-sac 7.4.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.7.
ICTIOBINAE sp. Yolk-sac 6.7.
ICTIOBINAE sp. Yolk-sac 7.4.
ICTIOBINAE sp. Yolk-sac 7.3.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.0.
ICTIOBINAE sp. Yolk-sac 7.2.
D-23 DRAFT
APPENDIX D (cont.)
ICTIOBINAE sp. Yolk-sac 7.3.
ICTIOBINAE sp. Yolk-sac 6.6.
ICTIOBINAE sp. Yolk-sac. 50 LOGPERCH type Yolk-sac 5.2.
LOGPERCH type Yolk-sac 5.6.
ROUND GOBY Juvenile 7.7.
ROUND GOBY Juvenile 7.1.
ROUND GOBY Juvenile 7.9.
ROUND GOBY Juvenile 7.9.
ROUND GOBY Juvenile 8.8.
ROUND GOBY Juvenile 7.7.
ROUND GOBY Juvenile 7.1.
ROUND GOBY Juvenile 7.5.
ROUND GOBY Juvenile 7.4.
ROUND GOBY Juvenile 7.3.
SAMPLE DATE: 28 May START DATE and TIME: 28MAY14:21:44 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.014447 STUDY GRAB TEMPERATURE (F): 75.0 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.8 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 25-31 May MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 7.1.
COMMON CARP Yolk-sac 7.5.
COMMON CARP Yolk-sac 7.7.
COMMON CARP Yolk-sac 6.8.
COMMON CARP Yolk-sac 7.1.
COMMON CARP Yolk-sac 6.2.
COMMON CARP Yolk-sac 6.8.
COMMON CARP Yolk-sac 7.1.
COMMON CARP Yolk-sac 7.5.
COMMON CARP Yolk-sac 6.9.
COMMON CARP Yolk-sac 7.2.
COMMON CARP Yolk-sac 7.2.
COMMON CARP Yolk-sac 7.0.
COMMON CARP Yolk-sac 7.0.
COMMON CARP Yolk-sac 6.6.
COMMON CARP Yolk-sac 6.8.
COMMON CARP Yolk-sac 7.1.
COMMON CARP Yolk-sac 7.2.
COMMON CARP Yolk-sac 6.6.
COMMON CARP Yolk-sac 7.1.
COMMON CARP Yolk-sac 7.7.
COMMON CARP Yolk-sac 6.9.
COMMON CARP Yolk-sac. 2 COMMON CARP Yolk-sac 7.5.
BLUNTNOSE MINNOW Juvenile 13.4.
BLUNTNOSE MINNOW Juvenile 16.4.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 2.4.
CYPRINIDAE sp. Yolk-sac 2.5.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 2.1.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 2.4.
CYPRINIDAE sp. Yolk-sac 2.7.
CYPRINIDAE sp. Yolk-sac 2.3.
CYPRINIDAE sp. Yolk-sac 2.4.
CYPRINIDAE sp. Yolk-sac 2.3.
ICTIOBINAE sp. Yolk-sac 6.3.
ICTIOBINAE sp. Yolk-sac 6.7.
ICTIOBINAE sp. Yolk-sac 7.5.
ICTIOBINAE sp. Yolk-sac 6.7.
ICTIOBINAE sp. Yolk-sac 7.1.
ICTIOBINAE sp. Yolk-sac 7.6.
ICTIOBINAE sp. Yolk-sac 7.6.
ICTIOBINAE sp. Yolk-sac 7.7.
ICTIOBINAE sp. Yolk-sac 7.1.
ICTIOBINAE sp. Yolk-sac 6.7.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.0.
ICTIOBINAE sp. Yolk-sac 6.4.
ICTIOBINAE sp. Yolk-sac 6.9.
ICTIOBINAE sp. Yolk-sac 7.3.
ICTIOBINAE sp. Yolk-sac 7.9.
ICTIOBINAE sp. Yolk-sac 7.3.
ICTIOBINAE sp. Yolk-sac 8.0.
ICTIOBINAE sp. Yolk-sac 8.6.
ICTIOBINAE sp. Yolk-sac 7.9.
ICTIOBINAE sp. Yolk-sac. 17 PUMPKINSEED type Yolk-sac 4.6.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
D-24 DRAFT
APPENDIX D (cont.)
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.2.
ROUND GOBY Juvenile 7.6.
ROUND GOBY Juvenile 7.0.
ROUND GOBY Juvenile 7.3.
ROUND GOBY Juvenile 6.5.
ROUND GOBY Juvenile 7.7.
ROUND GOBY Juvenile 7.2.
ROUND GOBY Juvenile 7.2.
ROUND GOBY Juvenile 7.5.
ROUND GOBY Juvenile 8.0.
Morone/Pomoxis type Egg 0.8.
SAMPLE DATE: 3 June START DATE and TIME: 03JUN14:17:52 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.013974 STUDY GRAB TEMPERATURE (F): 77.9 STUDY GRAB DISSOLVED OXYGEN (mg/L): 9.7 FOREBAY CURRENT VELOCITY (ft/sec): 1.27 EXTRAPOLATION PERIOD: 1-7 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 6.7.
Dorosoma sp. Post Yolk-sac 7.0.
Dorosoma sp. Post Yolk-sac 5.8.
Dorosoma sp. Post Yolk-sac 4.7.
Dorosoma sp. Post Yolk-sac 9.2.
Dorosoma sp. Post Yolk-sac 5.2.
Dorosoma sp. Post Yolk-sac 5.8.
Dorosoma sp. Post Yolk-sac 7.2.
Dorosoma sp. Post Yolk-sac 6.0.
Dorosoma sp. Post Yolk-sac 6.9.
Dorosoma sp. Post Yolk-sac 5.7.
Dorosoma sp. Post Yolk-sac 6.7.
Dorosoma sp. Post Yolk-sac 5.3.
Dorosoma sp. Post Yolk-sac 5.5.
CYPRINIDAE sp. Yolk-sac 4.8.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 2.1.
CYPRINIDAE sp. Yolk-sac 2.2.
CYPRINIDAE sp. Yolk-sac 2.3.
CYPRINIDAE sp. Yolk-sac 2.2.
CYPRINIDAE sp. Yolk-sac 1.8.
CYPRINIDAE sp. Yolk-sac 2.2.
CYPRINIDAE sp. Yolk-sac 2.0.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 1.6.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 2.2.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 1.6.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac. 121 Lepomis sp. Post Yolk-sac 7.8.
Sander sp. Yolk-sac 8.2.
FRESHWATER DRUM Post Yolk-sac 4.8.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.7.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg. 33 D-25 DRAFT
APPENDIX D (cont.)
SAMPLE DATE: 3 June START DATE and TIME: 03JUN14:17:52 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.014854 STUDY GRAB TEMPERATURE (F): 77.9 STUDY GRAB DISSOLVED OXYGEN (mg/L): 9.7 FOREBAY CURRENT VELOCITY (ft/sec): 1.27 EXTRAPOLATION PERIOD: 1-7 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT COMMON CARP Yolk-sac 8.0.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 1.2.
CYPRINIDAE sp. Yolk-sac 1.3.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 1.9.
CYPRINIDAE sp. Yolk-sac 2.2.
CYPRINIDAE sp. Yolk-sac 2.0.
CYPRINIDAE sp. Yolk-sac 2.3.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 1.2.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 1.2.
CYPRINIDAE sp. Yolk-sac 1.9.
CYPRINIDAE sp. Yolk-sac 1.8.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 1.3.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac. 53 FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.7.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg. 5 SAMPLE DATE: 3 June START DATE and TIME: 03JUN14:18:18 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.016012 STUDY GRAB TEMPERATURE (F): 77.9 STUDY GRAB DISSOLVED OXYGEN (mg/L): 9.7 FOREBAY CURRENT VELOCITY (ft/sec): 1.71 EXTRAPOLATION PERIOD: 1-7 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 5.3.
Dorosoma sp. Post Yolk-sac 5.1.
Dorosoma sp. Post Yolk-sac 4.7.
Dorosoma sp. Post Yolk-sac 4.5.
Dorosoma sp. Post Yolk-sac 4.4.
Dorosoma sp. Post Yolk-sac 4.7.
Dorosoma sp. Post Yolk-sac 4.6.
Dorosoma sp. Post Yolk-sac 4.5.
COMMON CARP Yolk-sac 7.7.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 2.2.
CYPRINIDAE sp. Yolk-sac 2.3.
CYPRINIDAE sp. Yolk-sac 2.5.
CYPRINIDAE sp. Yolk-sac 2.4.
CYPRINIDAE sp. Yolk-sac 2.3.
CYPRINIDAE sp. Yolk-sac 1.8.
CYPRINIDAE sp. Yolk-sac 1.3.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 1.9.
CYPRINIDAE sp. Yolk-sac 1.6.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 1.2.
CYPRINIDAE sp. Yolk-sac 1.3.
CYPRINIDAE sp. Yolk-sac 1.5.
D-26 DRAFT
APPENDIX D (cont.)
CYPRINIDAE sp. Yolk-sac 1.2.
CYPRINIDAE sp. Yolk-sac 1.2.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac. 73 CYPRINIDAE sp. Yolk-sac. 29 CYPRINIDAE sp. Yolk-sac. 49 PUMPKINSEED type Yolk-sac 4.2.
DARTER sp. Yolk-sac 9.5.
DARTER sp. Yolk-sac 9.7.
DARTER sp. Yolk-sac 6.4.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg. 12 SAMPLE DATE: 3 June START DATE and TIME: 03JUN14:18:18 SAMPLE DURATION (minutes): 9.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.014314 STUDY GRAB TEMPERATURE (F): 77.9 STUDY GRAB DISSOLVED OXYGEN (mg/L): 9.7 FOREBAY CURRENT VELOCITY (ft/sec): 1.71 EXTRAPOLATION PERIOD: 1-7 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Yolk-sac 4.7.
Dorosoma sp. Yolk-sac 4.9.
COMMON CARP Yolk-sac 7.6.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 5.0.
CYPRINIDAE sp. Yolk-sac 5.1.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 1.8.
CYPRINIDAE sp. Yolk-sac 2.2.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 2.4.
CYPRINIDAE sp. Yolk-sac 2.5.
CYPRINIDAE sp. Yolk-sac 2.2.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 1.8.
CYPRINIDAE sp. Yolk-sac 2.6.
CYPRINIDAE sp. Yolk-sac 2.4.
CYPRINIDAE sp. Yolk-sac 2.2.
CYPRINIDAE sp. Yolk-sac 2.5.
CYPRINIDAE sp. Yolk-sac 2.2.
CYPRINIDAE sp. Yolk-sac 2.6.
CYPRINIDAE sp. Yolk-sac 2.2.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 2.7.
CYPRINIDAE sp. Yolk-sac 2.0.
CYPRINIDAE sp. Yolk-sac 2.3.
CYPRINIDAE sp. Yolk-sac 2.0.
CYPRINIDAE sp. Yolk-sac. 25 PUMPKINSEED type Yolk-sac 4.0.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.7.
FRESHWATER DRUM Egg 1.5.
D-27 DRAFT
APPENDIX D (cont.)
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg. 5 SAMPLE DATE: 3 June START DATE and TIME: 03JUN14:20:38 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.013872 STUDY GRAB TEMPERATURE (F): 77.2 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.5 FOREBAY CURRENT VELOCITY (ft/sec): 1.80 EXTRAPOLATION PERIOD: 1-7 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 7.2.
Dorosoma sp. Post Yolk-sac 7.8.
Dorosoma sp. Post Yolk-sac 10.2.
Dorosoma sp. Post Yolk-sac 5.5.
Dorosoma sp. Post Yolk-sac 8.9.
Dorosoma sp. Post Yolk-sac 8.1.
Dorosoma sp. Post Yolk-sac 9.1.
Dorosoma sp. Post Yolk-sac 5.8.
Dorosoma sp. Post Yolk-sac 5.1.
COMMON CARP Yolk-sac 6.8.
COMMON CARP Yolk-sac 7.5.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 4.7.
Pimephales type Yolk-sac 6.1.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 5.8.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 5.4.
CYPRINIDAE sp. Yolk-sac 2.1.
CYPRINIDAE sp. Yolk-sac 2.8.
CYPRINIDAE sp. Yolk-sac 2.9.
CYPRINIDAE sp. Yolk-sac 2.1.
CYPRINIDAE sp. Yolk-sac 2.6.
CYPRINIDAE sp. Yolk-sac 2.6.
CYPRINIDAE sp. Yolk-sac 2.9.
CYPRINIDAE sp. Yolk-sac 2.8.
CYPRINIDAE sp. Yolk-sac 2.4.
CYPRINIDAE sp. Yolk-sac 2.8.
CYPRINIDAE sp. Yolk-sac 2.9.
CYPRINIDAE sp. Yolk-sac 2.7.
CYPRINIDAE sp. Yolk-sac 2.5.
CYPRINIDAE sp. Yolk-sac 2.1.
CYPRINIDAE sp. Yolk-sac 2.7.
CYPRINIDAE sp. Yolk-sac 2.3.
CYPRINIDAE sp. Yolk-sac 2.8.
CYPRINIDAE sp. Yolk-sac 2.3.
CYPRINIDAE sp. Yolk-sac 3.2.
CYPRINIDAE sp. Yolk-sac 2.9.
CYPRINIDAE sp. Yolk-sac. 6 Moxostoma sp. Post Yolk-sac 12.6.
BLUEGILL type Post Yolk-sac 5.3.
BLUEGILL type Post Yolk-sac 5.7.
BLUEGILL type Post Yolk-sac 5.4.
DARTER sp. Yolk-sac 6.9.
DARTER sp. Yolk-sac 7.4.
DARTER sp. Yolk-sac 6.6.
FRESHWATER DRUM Yolk-sac 3.8.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg. 14 FRESHWATER DRUM Yolk-sac 3.8.
D-28 DRAFT
APPENDIX D (cont.)
SAMPLE DATE: 3 June START DATE and TIME: 03JUN14:20:36 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.013382 STUDY GRAB TEMPERATURE (F): 77.2 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.5 FOREBAY CURRENT VELOCITY (ft/sec): 1.80 EXTRAPOLATION PERIOD: 1-7 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 5.0.
COMMON CARP Yolk-sac 8.8.
CYPRINIDAE sp. Yolk-sac 5.6.
CYPRINIDAE sp. Yolk-sac 2.9.
CYPRINIDAE sp. Yolk-sac 2.7.
CYPRINIDAE sp. Yolk-sac 2.8.
CYPRINIDAE sp. Yolk-sac 2.6.
CYPRINIDAE sp. Yolk-sac 3.1.
CYPRINIDAE sp. Yolk-sac 2.6.
CYPRINIDAE sp. Yolk-sac 3.2.
CYPRINIDAE sp. Yolk-sac 2.8.
CYPRINIDAE sp. Yolk-sac 2.6.
CYPRINIDAE sp. Yolk-sac 2.7.
CYPRINIDAE sp. Yolk-sac 2.7.
CYPRINIDAE sp. Yolk-sac 2.9.
CYPRINIDAE sp. Yolk-sac 2.8.
CYPRINIDAE sp. Yolk-sac 2.6.
CYPRINIDAE sp. Yolk-sac 2.4.
CYPRINIDAE sp. Yolk-sac 3.2.
CYPRINIDAE sp. Yolk-sac 2.3.
CYPRINIDAE sp. Yolk-sac 2.6.
CYPRINIDAE sp. Yolk-sac 2.4.
CYPRINIDAE sp. Yolk-sac 3.2.
CYPRINIDAE sp. Yolk-sac. 7 ICTIOBINAE sp. Yolk-sac 9.7.
PUMPKINSEED type Yolk-sac 6.5.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg. 4 SAMPLE DATE: 3 June START DATE and TIME: 03JUN14:21:02 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.015820 STUDY GRAB TEMPERATURE (F): 77.2 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.4 FOREBAY CURRENT VELOCITY (ft/sec): 1.70 EXTRAPOLATION PERIOD: 1-7 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 8.3.
Dorosoma sp. Post Yolk-sac 5.9.
Dorosoma sp. Post Yolk-sac 5.2.
Dorosoma sp. Post Yolk-sac 8.7.
Dorosoma sp. Post Yolk-sac 8.9.
Dorosoma sp. Post Yolk-sac 5.4.
Dorosoma sp. Post Yolk-sac 8.2.
Dorosoma sp. Post Yolk-sac 4.5.
Dorosoma sp. Post Yolk-sac 7.9.
Dorosoma sp. Post Yolk-sac 7.9.
Dorosoma sp. Post Yolk-sac 7.9.
Dorosoma sp. Post Yolk-sac 6.6.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 4.9.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 5.7.
D-29 DRAFT
APPENDIX D (cont.)
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 4.8.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 4.8.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac. 11 Semotilus type Yolk-sac 8.0.
CYPRINIDAE sp. Yolk-sac 5.0.
CYPRINIDAE sp. Yolk-sac 5.1.
CYPRINIDAE sp. Yolk-sac 5.0.
CYPRINIDAE sp. Yolk-sac 5.0.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 4.9.
CYPRINIDAE sp. Yolk-sac 5.0.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 4.8.
CYPRINIDAE sp. Yolk-sac 2.9.
CYPRINIDAE sp. Yolk-sac 2.9.
CYPRINIDAE sp. Yolk-sac 2.7.
CYPRINIDAE sp. Yolk-sac 2.5.
CYPRINIDAE sp. Yolk-sac 2.5.
CYPRINIDAE sp. Yolk-sac 2.0.
CYPRINIDAE sp. Yolk-sac 3.0.
CYPRINIDAE sp. Yolk-sac 3.0.
CYPRINIDAE sp. Yolk-sac 3.1.
CYPRINIDAE sp. Yolk-sac 2.8.
CYPRINIDAE sp. Yolk-sac 2.9.
CYPRINIDAE sp. Yolk-sac 2.7.
CYPRINIDAE sp. Yolk-sac 2.7.
CYPRINIDAE sp. Yolk-sac 2.8.
CYPRINIDAE sp. Yolk-sac 3.0.
CYPRINIDAE sp. Yolk-sac 2.7.
CYPRINIDAE sp. Yolk-sac 1.9.
CYPRINIDAE sp. Yolk-sac 2.4.
CYPRINIDAE sp. Yolk-sac 2.9.
CYPRINIDAE sp. Yolk-sac 2.5.
CYPRINIDAE sp. Yolk-sac. 43 PUMPKINSEED type Yolk-sac 5.0.
LOGPERCH type Yolk-sac 5.5.
DARTER sp. Post Yolk-sac 13.4.
DARTER sp. Yolk-sac 7.2.
DARTER sp. Yolk-sac 6.9.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.1.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.1.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg. 11 ROUND GOBY Juvenile 7.3.
ROUND GOBY Juvenile 7.6.
ROUND GOBY Juvenile 7.2.
ROUND GOBY Juvenile 7.4.
ROUND GOBY Juvenile 7.4.
ROUND GOBY Juvenile 7.8.
ROUND GOBY Juvenile 7.7.
ROUND GOBY Juvenile 7.6.
ROUND GOBY Juvenile 7.4.
ROUND GOBY Juvenile 7.4.
ROUND GOBY Juvenile 7.7.
ROUND GOBY Juvenile 7.7.
ROUND GOBY Juvenile 7.4.
ROUND GOBY Juvenile 7.6.
ROUND GOBY Juvenile 7.1.
ROUND GOBY Juvenile 7.5.
ROUND GOBY Juvenile 6.9.
ROUND GOBY Juvenile 7.4.
ROUND GOBY Juvenile 7.4.
D-30 DRAFT
APPENDIX D (cont.)
SAMPLE DATE: 3 June START DATE and TIME: 03JUN14:21:01 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.014004 STUDY GRAB TEMPERATURE (F): 77.2 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.4 FOREBAY CURRENT VELOCITY (ft/sec): 1.70 EXTRAPOLATION PERIOD: 1-7 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 5.0.
Dorosoma sp. Post Yolk-sac 7.2.
Dorosoma sp. Post Yolk-sac 5.1.
COMMON CARP Yolk-sac 7.0.
COMMON CARP Yolk-sac 7.0.
BLUNTNOSE MINNOW Post Yolk-sac 16.6.
Pimephales type Yolk-sac 5.3.
Pimephales type Yolk-sac 4.9.
Pimephales type Yolk-sac 5.5.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 4.9.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 4.9.
Pimephales type Yolk-sac 5.1.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 6.7.
CYPRINIDAE sp. Yolk-sac 2.9.
CYPRINIDAE sp. Yolk-sac 2.4.
CYPRINIDAE sp. Yolk-sac 2.9.
CYPRINIDAE sp. Yolk-sac 2.6.
CYPRINIDAE sp. Yolk-sac 2.8.
CYPRINIDAE sp. Yolk-sac 2.4.
CYPRINIDAE sp. Yolk-sac 2.7.
CYPRINIDAE sp. Yolk-sac 2.7.
CYPRINIDAE sp. Yolk-sac 2.8.
CYPRINIDAE sp. Yolk-sac 2.9.
CYPRINIDAE sp. Yolk-sac 2.6.
CYPRINIDAE sp. Yolk-sac 2.9.
CYPRINIDAE sp. Yolk-sac 3.2.
CYPRINIDAE sp. Yolk-sac 2.6.
CYPRINIDAE sp. Yolk-sac 3.0.
CYPRINIDAE sp. Yolk-sac 2.6.
CYPRINIDAE sp. Yolk-sac 1.8.
CYPRINIDAE sp. Yolk-sac 2.6.
CYPRINIDAE sp. Yolk-sac. 8 CYPRINIDAE sp. Yolk-sac 2.4.
CYPRINIDAE sp. Yolk-sac 2.3.
Moxostoma sp. Post Yolk-sac 17.0.
ICTIOBINAE sp. Post Yolk-sac 7.9.
DARTER sp. Yolk-sac 6.5.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg. 5 FRESHWATER DRUM Yolk-sac 2.5.
ROUND GOBY Juvenile 7.4.
ROUND GOBY Juvenile 7.5.
ROUND GOBY Juvenile 7.3.
ROUND GOBY Juvenile 7.6.
ROUND GOBY Juvenile 7.4.
ROUND GOBY Juvenile 7.7.
ROUND GOBY Juvenile 7.2.
ROUND GOBY Juvenile 7.0.
ROUND GOBY Juvenile 7.3.
ROUND GOBY Juvenile 7.4.
ROUND GOBY Juvenile 7.3.
UNIDENTIFIED Yolk-sac 1.9.
UNIDENTIFIED Yolk-sac 2.3.
UNIDENTIFIED Yolk-sac 1.9.
D-31 DRAFT
APPENDIX D (cont.)
SAMPLE DATE: 11 June START DATE and TIME: 11JUN14:18:00 SAMPLE DURATION (minutes): 14.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.013635 STUDY GRAB TEMPERATURE (F): 72.1 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.7 FOREBAY CURRENT VELOCITY (ft/sec): 1.00 EXTRAPOLATION PERIOD: 8-14 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT COMMON CARP Egg 1.5.
COMMON CARP Egg 1.3.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.3.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.0.
COMMON CARP Egg 1.6.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.6.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.0.
COMMON CARP Egg 1.1.
COMMON CARP Egg 1.7.
COMMON CARP Egg. 46 Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.1.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 6.2.
Pimephales type Post Yolk-sac 9.6.
Pimephales type Post Yolk-sac 10.4.
CYPRINIDAE sp. Yolk-sac 5.4.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 6.4.
CYPRINIDAE sp. Yolk-sac 5.4.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 6.1.
Moxostoma sp. Post Yolk-sac 12.2.
ROCK BASS Post Yolk-sac 10.3.
LOGPERCH type Yolk-sac 5.2.
SAMPLE DATE: 11 June START DATE and TIME: 11JUN14:17:32 SAMPLE DURATION (minutes): 15.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.014296 STUDY GRAB TEMPERATURE (F): 72.1 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.7 FOREBAY CURRENT VELOCITY (ft/sec): 1.00 EXTRAPOLATION PERIOD: 8-14 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 10.7.
Dorosoma sp. Post Yolk-sac 15.1.
Dorosoma sp. Post Yolk-sac 10.6.
Dorosoma sp. Post Yolk-sac 7.1.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.6.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.6.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.6.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.6.
COMMON CARP Egg. 58 CYPRINIDAE sp. Post Yolk-sac 6.7.
CYPRINIDAE sp. Post Yolk-sac 5.9.
CYPRINIDAE sp. Post Yolk-sac 6.3.
CYPRINIDAE sp. Post Yolk-sac 6.3.
CYPRINIDAE sp. Post Yolk-sac 6.6.
D-32 DRAFT
APPENDIX D (cont.)
CYPRINIDAE sp. Post Yolk-sac 5.8.
CYPRINIDAE sp. Post Yolk-sac 6.6.
CYPRINIDAE sp. Post Yolk-sac 6.9.
CYPRINIDAE sp. Post Yolk-sac 5.8.
CYPRINIDAE sp. Post Yolk-sac 6.3.
CYPRINIDAE sp. Yolk-sac 4.8.
CYPRINIDAE sp. Yolk-sac 4.6.
CYPRINIDAE sp. Yolk-sac 4.8.
Moxostoma sp. Post Yolk-sac 13.0.
LOGPERCH type Yolk-sac 5.7.
LOGPERCH type Yolk-sac 5.8.
DARTER sp. Post Yolk-sac 13.4.
DARTER sp. Post Yolk-sac 9.7.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.7.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.1.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg. 9 SAMPLE DATE: 11 June START DATE and TIME: 11JUN14:18:05 SAMPLE DURATION (minutes): 16.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.013728 STUDY GRAB TEMPERATURE (F): 71.8 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.8 FOREBAY CURRENT VELOCITY (ft/sec): 1.46 EXTRAPOLATION PERIOD: 8-14 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT GAR sp. Post Yolk-sac 26.1.
Dorosoma sp. Post Yolk-sac 6.2.
Dorosoma sp. Post Yolk-sac 10.2.
Dorosoma sp. Post Yolk-sac 13.5.
Dorosoma sp. Post Yolk-sac 8.3.
Dorosoma sp. Post Yolk-sac 8.2.
Dorosoma sp. Post Yolk-sac 15.2.
Dorosoma sp. Post Yolk-sac 10.2.
COMMON CARP Yolk-sac 5.5.
COMMON CARP Yolk-sac 6.6.
COMMON CARP Yolk-sac 4.5.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.6.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.6.
COMMON CARP Egg 1.6.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.0.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.1.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.2.
COMMON CARP Egg 1.2.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.6.
COMMON CARP Egg 1.5.
COMMON CARP Egg. 31 CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 5.8.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 5.0.
CYPRINIDAE sp. Yolk-sac 5.0.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Post Yolk-sac 8.2.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 5.8.
PUMPKINSEED type Yolk-sac 5.7.
D-33 DRAFT
APPENDIX D (cont.)
LOGPERCH type Yolk-sac 6.1.
LOGPERCH type Yolk-sac 5.0.
DARTER sp. Yolk-sac 8.5.
DARTER sp. Post Yolk-sac 7.5.
DARTER sp. Post Yolk-sac 10.8.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 0.8.
FRESHWATER DRUM Egg 0.9.
FRESHWATER DRUM Egg 1.1.
FRESHWATER DRUM Egg 1.2.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.3.
ROUND GOBY Juvenile 7.7.
UNIDENTIFIED Yolk-sac 2.9.
SAMPLE DATE: 11 June START DATE and TIME: 11JUN14:18:33 SAMPLE DURATION (minutes): 14.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.015437 STUDY GRAB TEMPERATURE (F): 71.8 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.8 FOREBAY CURRENT VELOCITY (ft/sec): 1.46 EXTRAPOLATION PERIOD: 8-14 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 7.6.
Dorosoma sp. Post Yolk-sac 15.2.
Dorosoma sp. Post Yolk-sac 13.7.
Dorosoma sp. Post Yolk-sac 10.5.
Dorosoma sp. Post Yolk-sac 8.7.
Dorosoma sp. Post Yolk-sac 8.8.
COMMON CARP Yolk-sac 7.4.
COMMON CARP Yolk-sac 5.1.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.1.
COMMON CARP Egg 1.0.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.0.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.2.
COMMON CARP Egg 1.3.
COMMON CARP Egg 1.2.
COMMON CARP Egg 1.2.
COMMON CARP Egg 1.3.
COMMON CARP Egg 1.0.
COMMON CARP Egg 1.0.
COMMON CARP Egg 1.3.
COMMON CARP Egg 1.0.
COMMON CARP Egg 1.1.
COMMON CARP Egg 1.1.
COMMON CARP Egg. 59 Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 6.6.
CYPRINIDAE sp. Yolk-sac 7.0.
CYPRINIDAE sp. Yolk-sac 6.6.
CYPRINIDAE sp. Yolk-sac 8.2.
CYPRINIDAE sp. Yolk-sac 6.6.
CYPRINIDAE sp. Yolk-sac 6.7.
CYPRINIDAE sp. Yolk-sac 6.6.
CYPRINIDAE sp. Yolk-sac 6.4.
CYPRINIDAE sp. Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 5.8.
CYPRINIDAE sp. Yolk-sac 6.8.
CYPRINIDAE sp. Yolk-sac 6.4.
CYPRINIDAE sp. Yolk-sac 7.9.
CYPRINIDAE sp. Yolk-sac 6.3.
CYPRINIDAE sp. Yolk-sac 6.7.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 6.5.
CYPRINIDAE sp. Yolk-sac 6.8.
CYPRINIDAE sp. Yolk-sac 7.0.
CYPRINIDAE sp. Yolk-sac 5.5.
CYPRINIDAE sp. Yolk-sac 5.7.
PUMPKINSEED type Yolk-sac 4.7.
PUMPKINSEED type Yolk-sac 5.2.
DARTER sp. Post Yolk-sac 13.8.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
D-34 DRAFT
APPENDIX D (cont.)
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.4.
SAMPLE DATE: 11 June START DATE and TIME: 11JUN14:20:43 SAMPLE DURATION (minutes): 15.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.013742 STUDY GRAB TEMPERATURE (F): 71.4 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.4 FOREBAY CURRENT VELOCITY (ft/sec): 1.00 EXTRAPOLATION PERIOD: 8-14 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 4.3.
Dorosoma sp. Post Yolk-sac 5.2.
Dorosoma sp. Post Yolk-sac 6.6.
Dorosoma sp. Post Yolk-sac 10.1.
Dorosoma sp. Post Yolk-sac 10.7.
COMMON CARP Yolk-sac 7.2.
COMMON CARP Yolk-sac 7.5.
COMMON CARP Yolk-sac 7.3.
COMMON CARP Yolk-sac 5.7.
COMMON CARP Yolk-sac 6.4.
COMMON CARP Yolk-sac 6.3.
COMMON CARP Yolk-sac 5.9.
COMMON CARP Egg 1.2.
COMMON CARP Egg 1.3.
COMMON CARP Egg 1.2.
COMMON CARP Egg 1.3.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.0.
COMMON CARP Egg 1.1.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.0.
COMMON CARP Egg 1.0.
COMMON CARP Egg 1.0.
COMMON CARP Egg 1.2.
COMMON CARP Egg 1.1.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.3.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.3.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.4.
COMMON CARP Egg. 11 Pimephales type Yolk-sac 6.1.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 4.9.
Pimephales type Yolk-sac 5.1.
Pimephales type Yolk-sac 5.1.
Pimephales type Yolk-sac 4.8.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 6.1.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 6.3.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 6.1.
CYPRINIDAE sp. Yolk-sac 6.5.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 6.1.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 6.3.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 6.1.
CYPRINIDAE sp. Yolk-sac 5.6.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 5.0.
CYPRINIDAE sp. Yolk-sac 5.4.
CYPRINIDAE sp. Yolk-sac 5.4.
Moxostoma sp. Post Yolk-sac 14.7.
ICTIOBINAE sp. Post Yolk-sac 20.2.
PUMPKINSEED type Yolk-sac 5.8.
LOGPERCH type Yolk-sac 5.3.
DARTER sp. Yolk-sac 8.7.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.3.
ROUND GOBY Juvenile 8.9.
D-35 DRAFT
APPENDIX D (cont.)
SAMPLE DATE: 11 June START DATE and TIME: 11JUN14:20:43 SAMPLE DURATION (minutes): 15.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.017308 STUDY GRAB TEMPERATURE (F): 71.4 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.4 FOREBAY CURRENT VELOCITY (ft/sec): 1.00 EXTRAPOLATION PERIOD: 8-14 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 7.2.
Dorosoma sp. Post Yolk-sac 7.0.
Dorosoma sp. Post Yolk-sac 9.2.
Dorosoma sp. Post Yolk-sac 10.2.
Dorosoma sp. Post Yolk-sac 12.0.
Dorosoma sp. Post Yolk-sac 15.7.
Dorosoma sp. Post Yolk-sac 8.3.
Dorosoma sp. Post Yolk-sac 12.2.
Dorosoma sp. Post Yolk-sac 9.1.
COMMON CARP Yolk-sac 6.0.
COMMON CARP Yolk-sac 6.9.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 5.8.
COMMON CARP Yolk-sac 5.4.
COMMON CARP Yolk-sac 5.3.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.1.
COMMON CARP Egg 1.6.
COMMON CARP Egg 1.3.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.1.
COMMON CARP Egg 1.1.
COMMON CARP Egg 1.2.
COMMON CARP Egg 1.3.
COMMON CARP Egg 1.6.
COMMON CARP Egg 1.2.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.3.
COMMON CARP Egg 1.3.
COMMON CARP Egg 1.3.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.6.
Pimephales type Yolk-sac 4.7.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 4.9.
Semotilus type Post Yolk-sac 12.2.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 4.5.
CYPRINIDAE sp. Yolk-sac 4.7.
CYPRINIDAE sp. Yolk-sac 1.6.
CYPRINIDAE sp. Yolk-sac 1.2.
CYPRINIDAE sp. Yolk-sac 1.2.
CYPRINIDAE sp. Yolk-sac 1.3.
CYPRINIDAE sp. Yolk-sac 1.6.
CYPRINIDAE sp. Yolk-sac 1.2.
CYPRINIDAE sp. Yolk-sac 1.3.
DARTER sp. Yolk-sac 8.2.
DARTER sp. Post Yolk-sac 16.5.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
ROUND GOBY Juvenile 7.2.
ROUND GOBY Juvenile 13.4.
ROUND GOBY Juvenile 11.8.
SAMPLE DATE: 11 June START DATE and TIME: 11JUN14:21:12 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.014231 STUDY GRAB TEMPERATURE (F): 71.4 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.3 FOREBAY CURRENT VELOCITY (ft/sec): 1.55 EXTRAPOLATION PERIOD: 8-14 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 13.6.
Dorosoma sp. Post Yolk-sac 8.9.
Dorosoma sp. Post Yolk-sac 8.2.
Dorosoma sp. Post Yolk-sac 11.7.
Dorosoma sp. Post Yolk-sac 13.3.
COMMON CARP Yolk-sac 6.6.
COMMON CARP Yolk-sac 6.4.
D-36 DRAFT
APPENDIX D (cont.)
COMMON CARP Yolk-sac 5.6.
COMMON CARP Yolk-sac 5.5.
COMMON CARP Yolk-sac 7.4.
COMMON CARP Egg 1.1.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.1.
COMMON CARP Egg 1.3.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.2.
COMMON CARP Egg 1.3.
COMMON CARP Egg 1.3.
COMMON CARP Egg 1.2.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 6.1.
Pimephales type Yolk-sac 4.9.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 4.8.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 7.2.
CYPRINIDAE sp. Yolk-sac 6.6.
CYPRINIDAE sp. Yolk-sac 5.6.
CYPRINIDAE sp. Yolk-sac 6.6.
CYPRINIDAE sp. Yolk-sac 6.4.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 5.6.
CYPRINIDAE sp. Yolk-sac 5.4.
CYPRINIDAE sp. Yolk-sac 6.7.
CYPRINIDAE sp. Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 1.2.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 1.3.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 2.1.
CYPRINIDAE sp. Yolk-sac 1.2.
Moxostoma sp. Post Yolk-sac 12.4.
Moxostoma sp. Post Yolk-sac 13.7.
Moxostoma sp. Post Yolk-sac 14.9.
DARTER sp. Post Yolk-sac 9.8.
FRESHWATER DRUM Egg 1.4.
ROUND GOBY Juvenile 7.7.
ROUND GOBY Juvenile 6.9.
ROUND GOBY Juvenile 7.9.
ROUND GOBY Juvenile 7.4.
ROUND GOBY Juvenile 7.7.
ROUND GOBY Juvenile 7.5.
ROUND GOBY Juvenile 15.3.
ROUND GOBY Juvenile 17.7.
SAMPLE DATE: 11 June START DATE and TIME: 11JUN14:21:12 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.013914 STUDY GRAB TEMPERATURE (F): 71.4 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.3 FOREBAY CURRENT VELOCITY (ft/sec): 1.55 EXTRAPOLATION PERIOD: 8-14 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 10.7.
Dorosoma sp. Post Yolk-sac 11.3.
Dorosoma sp. Post Yolk-sac 8.2.
COMMON CARP Yolk-sac 5.6.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 6.7.
COMMON CARP Egg 1.1.
COMMON CARP Egg 1.0.
COMMON CARP Egg 1.0.
COMMON CARP Egg 1.3.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.1.
COMMON CARP Egg 1.1.
COMMON CARP Egg 1.3.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.3.
Pimephales type Yolk-sac 4.8.
Pimephales type Yolk-sac 4.9.
Pimephales type Yolk-sac 5.5.
CYPRINIDAE sp. Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 7.2.
CYPRINIDAE sp. Yolk-sac 2.4.
CYPRINIDAE sp. Yolk-sac 1.7.
D-37 DRAFT
APPENDIX D (cont.)
CYPRINIDAE sp. Yolk-sac 1.2.
CYPRINIDAE sp. Yolk-sac 2.0.
CYPRINIDAE sp. Yolk-sac 1.5.
ROCK BASS Post Yolk-sac 7.5.
DARTER sp. Post Yolk-sac 13.1.
DARTER sp. Post Yolk-sac 12.3.
DARTER sp. Post Yolk-sac 10.0.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.3.
ROUND GOBY Juvenile 7.2.
ROUND GOBY Juvenile 7.0.
ROUND GOBY Juvenile 7.3.
ROUND GOBY Juvenile 7.0.
ROUND GOBY Juvenile 8.0.
ROUND GOBY Juvenile 7.9.
ROUND GOBY Juvenile 7.7.
ROUND GOBY Juvenile 21.5.
SAMPLE DATE: 17 June START DATE and TIME: 17JUN14:17:30 SAMPLE DURATION (minutes): 21.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.013897 STUDY GRAB TEMPERATURE (F): 77.9 STUDY GRAB DISSOLVED OXYGEN (mg/L): 9.5 FOREBAY CURRENT VELOCITY (ft/sec): 1.00 EXTRAPOLATION PERIOD: 15-21 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 5.4.
Dorosoma sp. Post Yolk-sac 5.3.
Dorosoma sp. Post Yolk-sac 5.2.
Dorosoma sp. Post Yolk-sac 6.0.
Dorosoma sp. Post Yolk-sac 5.5.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.2.
COMMON CARP Egg 1.2.
Pimephales type Yolk-sac 6.4.
Pimephales type Yolk-sac 7.0.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 6.1.
Pimephales type Yolk-sac 4.9.
Pimephales type Yolk-sac 5.3.
Pimephales type Yolk-sac 6.1.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 6.3.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 5.3.
Pimephales type Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 5.8.
CYPRINIDAE sp. Yolk-sac 6.4.
CYPRINIDAE sp. Yolk-sac 7.0.
CYPRINIDAE sp. Yolk-sac 6.3.
CYPRINIDAE sp. Yolk-sac 6.3.
CYPRINIDAE sp. Yolk-sac 6.1.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 1.3.
CYPRINIDAE sp. Yolk-sac 1.8.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 1.3.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 2.1.
CYPRINIDAE sp. Yolk-sac 1.3.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 1.3.
CYPRINIDAE sp. Yolk-sac 1.3.
CYPRINIDAE sp. Yolk-sac 1.8.
CYPRINIDAE sp. Yolk-sac 1.2.
CYPRINIDAE sp. Yolk-sac 1.8.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 1.3.
CYPRINIDAE sp. Yolk-sac 1.8.
CYPRINIDAE sp. Yolk-sac 2.1.
CYPRINIDAE sp. Yolk-sac 2.8.
CYPRINIDAE sp. Yolk-sac. 71 DARTER sp. Yolk-sac 7.1.
DARTER sp. Yolk-sac 6.8.
D-38 DRAFT
APPENDIX D (cont.)
SAMPLE DATE: 17 June START DATE and TIME: 17JUN14:17:30 SAMPLE DURATION (minutes): 17.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.013677 STUDY GRAB TEMPERATURE (F): 77.9 STUDY GRAB DISSOLVED OXYGEN (mg/L): 9.5 FOREBAY CURRENT VELOCITY (ft/sec): 1.00 EXTRAPOLATION PERIOD: 15-21 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Yolk-sac 6.6.
Dorosoma sp. Yolk-sac 6.5.
Dorosoma sp. Yolk-sac 7.4.
Dorosoma sp. Yolk-sac 6.7.
Dorosoma sp. Yolk-sac 7.7.
Dorosoma sp. Post Yolk-sac 11.8.
Dorosoma sp. Post Yolk-sac 9.1.
Dorosoma sp. Yolk-sac 5.7.
Dorosoma sp. Post Yolk-sac 11.9.
Dorosoma sp. Yolk-sac 6.2.
Dorosoma sp. Yolk-sac 6.7.
Dorosoma sp. Yolk-sac 6.6.
Dorosoma sp. Yolk-sac 5.6.
Dorosoma sp. Yolk-sac 5.9.
Dorosoma sp. Yolk-sac 7.0.
Dorosoma sp. Yolk-sac 6.1.
Dorosoma sp. Yolk-sac 5.2.
Dorosoma sp. Yolk-sac 5.9.
COMMON CARP Yolk-sac 7.3.
COMMON CARP Egg 1.2.
COMMON CARP Egg 1.3.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 6.3.
Pimephales type Yolk-sac 5.3.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 5.0.
CYPRINIDAE sp. Yolk-sac 6.3.
CYPRINIDAE sp. Yolk-sac 6.5.
CYPRINIDAE sp. Yolk-sac 6.6.
CYPRINIDAE sp. Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac. 4 CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 1.6.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 2.1.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 2.1.
CYPRINIDAE sp. Yolk-sac 1.3.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 1.6.
CYPRINIDAE sp. Yolk-sac 1.9.
CYPRINIDAE sp. Yolk-sac 2.1.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 1.6.
CYPRINIDAE sp. Yolk-sac 2.4.
CYPRINIDAE sp. Yolk-sac 1.9.
CYPRINIDAE sp. Yolk-sac. 49 ICTIOBINAE sp. Yolk-sac 6.2.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 7.5.
ICTIOBINAE sp. Yolk-sac 6.2.
ICTIOBINAE sp. Yolk-sac 6.3.
ICTIOBINAE sp. Yolk-sac 6.6.
ICTIOBINAE sp. Yolk-sac 7.3.
ICTIOBINAE sp. Yolk-sac 6.1.
Lepomis sp. Post Yolk-sac 6.1.
DARTER sp. Yolk-sac 6.6.
FRESHWATER DRUM Yolk-sac 3.9.
SAMPLE DATE: 17 June START DATE and TIME: 17JUN14:18:07 SAMPLE DURATION (minutes): 18.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.013563 STUDY GRAB TEMPERATURE (F): 77.5 STUDY GRAB DISSOLVED OXYGEN (mg/L): 9.5 FOREBAY CURRENT VELOCITY (ft/sec): 1.53 EXTRAPOLATION PERIOD: 15-21 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 7.2.
Dorosoma sp. Post Yolk-sac 6.3.
Dorosoma sp. Post Yolk-sac 10.1.
D-39 DRAFT
APPENDIX D (cont.)
Dorosoma sp. Post Yolk-sac 12.1.
Dorosoma sp. Post Yolk-sac 10.9.
Dorosoma sp. Post Yolk-sac 16.5.
COMMON CARP Egg 1.3.
COMMON CARP Egg 1.2.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.3.
COMMON CARP Yolk-sac 7.6.
COMMON CARP Yolk-sac 6.4.
Pimephales type Yolk-sac 5.5.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 6.1.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 6.1.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 6.1.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 6.5.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac. 36 Pimephales type Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 1.2.
CYPRINIDAE sp. Yolk-sac 1.2.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 1.3.
CYPRINIDAE sp. Yolk-sac 1.2.
CYPRINIDAE sp. Yolk-sac 1.2.
CYPRINIDAE sp. Yolk-sac 1.8.
CYPRINIDAE sp. Yolk-sac 1.2.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 1.8.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 1.2.
CYPRINIDAE sp. Yolk-sac 1.3.
CYPRINIDAE sp. Yolk-sac 2.0.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac. 15 CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 5.0.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 5.8.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 5.5.
CYPRINIDAE sp. Yolk-sac 5.6.
CYPRINIDAE sp. Yolk-sac 5.6.
CYPRINIDAE sp. Yolk-sac 5.8.
CYPRINIDAE sp. Yolk-sac 5.5.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 6.1.
CYPRINIDAE sp. Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 5.5.
CYPRINIDAE sp. Yolk-sac. 5 ICTIOBINAE sp. Yolk-sac 6.3.
ICTIOBINAE sp. Yolk-sac 6.8.
ICTIOBINAE sp. Yolk-sac 6.6.
PUMPKINSEED type Yolk-sac 5.7.
PUMPKINSEED type Yolk-sac 5.3.
DARTER sp. Post Yolk-sac 13.4.
DARTER sp. Yolk-sac 8.8.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.4.
D-40 DRAFT
APPENDIX D (cont.)
FRESHWATER DRUM Egg 2.1.
FRESHWATER DRUM Egg 1.9.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.7.
UNIDENTIFIED Yolk-sac 3.9.
SAMPLE DATE: 17 June START DATE and TIME: 17JUN14:18:07 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.013734 STUDY GRAB TEMPERATURE (F): 77.5 STUDY GRAB DISSOLVED OXYGEN (mg/L): 9.5 FOREBAY CURRENT VELOCITY (ft/sec): 1.53 EXTRAPOLATION PERIOD: 15-21 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 11.1.
Dorosoma sp. Post Yolk-sac 10.0.
Dorosoma sp. Post Yolk-sac 6.6.
Dorosoma sp. Post Yolk-sac 6.1.
Dorosoma sp. Post Yolk-sac 10.1.
Dorosoma sp. Post Yolk-sac 6.8.
Dorosoma sp. Post Yolk-sac 6.4.
Dorosoma sp. Post Yolk-sac 6.2.
Dorosoma sp. Post Yolk-sac 4.7.
Dorosoma sp. Post Yolk-sac 6.8.
Dorosoma sp. Post Yolk-sac 9.5.
COMMON CARP Egg 1.3.
COMMON CARP Egg 1.4.
Pimephales type Yolk-sac 5.3.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 4.7.
Pimephales type Yolk-sac 6.4.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 4.9.
Pimephales type Yolk-sac 4.7.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 6.1.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac. 11 CYPRINIDAE sp. Yolk-sac 5.6.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 6.1.
CYPRINIDAE sp. Yolk-sac 6.3.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 5.5.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 5.8.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 1.2.
CYPRINIDAE sp. Yolk-sac 2.1.
CYPRINIDAE sp. Yolk-sac 1.9.
CYPRINIDAE sp. Yolk-sac 2.1.
CYPRINIDAE sp. Yolk-sac 2.2.
CYPRINIDAE sp. Yolk-sac 1.8.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 2.2.
CYPRINIDAE sp. Yolk-sac 1.3.
CYPRINIDAE sp. Yolk-sac 1.3.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 1.9.
CYPRINIDAE sp. Yolk-sac 1.7.
CYPRINIDAE sp. Yolk-sac 1.2.
CYPRINIDAE sp. Yolk-sac 1.2.
CYPRINIDAE sp. Yolk-sac 2.5.
CYPRINIDAE sp. Yolk-sac 1.6.
CYPRINIDAE sp. Yolk-sac 1.3.
CYPRINIDAE sp. Yolk-sac 1.5.
D-41 DRAFT
APPENDIX D (cont.)
CYPRINIDAE sp. Yolk-sac. 51 ICTIOBINAE sp. Yolk-sac 6.4.
ICTIOBINAE sp. Yolk-sac 6.7.
ICTIOBINAE sp. Yolk-sac 6.9.
ICTIOBINAE sp. Yolk-sac 6.4.
PUMPKINSEED type Yolk-sac 5.7.
DARTER sp. Yolk-sac 7.4.
DARTER sp. Yolk-sac 7.2.
DARTER sp. Yolk-sac 6.9.
DARTER sp. Post Yolk-sac 10.0.
SAMPLE DATE: 17 June START DATE and TIME: 17JUN14:20:32 SAMPLE DURATION (minutes): 15.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.013794 STUDY GRAB TEMPERATURE (F): 77.2 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.3 FOREBAY CURRENT VELOCITY (ft/sec): 1.00 EXTRAPOLATION PERIOD: 15-21 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 6.1.
Dorosoma sp. Post Yolk-sac 9.4.
Dorosoma sp. Post Yolk-sac 8.5.
Dorosoma sp. Post Yolk-sac 7.7.
Dorosoma sp. Post Yolk-sac 8.1.
Dorosoma sp. Post Yolk-sac 6.4.
COMMON CARP Egg 1.2.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.3.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 4.7.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 4.8.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 5.3.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 5.1.
Pimephales type Yolk-sac 6.3.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 5.5.
Pimephales type Yolk-sac 5.1.
Pimephales type Yolk-sac 5.3.
Pimephales type Yolk-sac 6.1.
Pimephales type Yolk-sac 6.1.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 6.1.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 5.1.
CYPRINIDAE sp. Yolk-sac 5.6.
CYPRINIDAE sp. Yolk-sac 5.1.
CYPRINIDAE sp. Yolk-sac 6.4.
CYPRINIDAE sp. Yolk-sac 6.3.
CYPRINIDAE sp. Yolk-sac 6.3.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 5.6.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 2.2.
CYPRINIDAE sp. Yolk-sac 2.7.
CYPRINIDAE sp. Yolk-sac 3.0.
CYPRINIDAE sp. Yolk-sac 2.8.
CYPRINIDAE sp. Yolk-sac 1.8.
CYPRINIDAE sp. Yolk-sac 2.6.
CYPRINIDAE sp. Yolk-sac 2.8.
CYPRINIDAE sp. Yolk-sac 2.5.
CYPRINIDAE sp. Yolk-sac 1.5.
CYPRINIDAE sp. Yolk-sac 2.2.
CYPRINIDAE sp. Yolk-sac 2.7.
CYPRINIDAE sp. Yolk-sac 2.5.
CYPRINIDAE sp. Yolk-sac 1.9.
CYPRINIDAE sp. Yolk-sac 2.7.
CYPRINIDAE sp. Yolk-sac 2.3.
CYPRINIDAE sp. Yolk-sac 2.4.
CYPRINIDAE sp. Yolk-sac 2.8.
ICTIOBINAE sp. Yolk-sac 7.7.
PUMPKINSEED type Yolk-sac 5.6.
LOGPERCH type Yolk-sac 6.7.
LOGPERCH type Yolk-sac 6.3.
DARTER sp. Yolk-sac 7.5.
DARTER sp. Yolk-sac 7.0.
DARTER sp. Yolk-sac 7.2.
DARTER sp. Yolk-sac 7.2.
D-42 DRAFT
APPENDIX D (cont.)
DARTER sp. Yolk-sac 6.8.
DARTER sp. Yolk-sac 6.1.
DARTER sp. Yolk-sac 6.3.
FRESHWATER DRUM Post Yolk-sac 9.7.
FRESHWATER DRUM Post Yolk-sac 7.3.
FRESHWATER DRUM Post Yolk-sac 7.4.
FRESHWATER DRUM Egg 1.3.
FRESHWATER DRUM Egg 1.4.
FRESHWATER DRUM Egg 1.5.
SAMPLE DATE: 17 June START DATE and TIME: 17JUN14:20:32 SAMPLE DURATION (minutes): 17.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.013818 STUDY GRAB TEMPERATURE (F): 77.2 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.3 FOREBAY CURRENT VELOCITY (ft/sec): 1.00 EXTRAPOLATION PERIOD: 15-21 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 9.7.
Dorosoma sp. Post Yolk-sac 10.3.
Dorosoma sp. Post Yolk-sac 5.1.
Dorosoma sp. Post Yolk-sac 10.0.
Dorosoma sp. Post Yolk-sac 7.6.
Dorosoma sp. Post Yolk-sac 5.2.
Dorosoma sp. Post Yolk-sac 11.5.
Dorosoma sp. Post Yolk-sac 16.7.
Dorosoma sp. Post Yolk-sac 7.1.
Dorosoma sp. Post Yolk-sac 9.2.
Dorosoma sp. Post Yolk-sac 10.0.
Dorosoma sp. Post Yolk-sac 12.4.
Dorosoma sp. Post Yolk-sac 17.2.
Dorosoma sp. Post Yolk-sac 6.1.
Dorosoma sp. Post Yolk-sac 5.3.
COMMON CARP Egg 1.3.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.3.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.0.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.3.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.5.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 6.1.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 6.3.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 6.4.
Pimephales type Yolk-sac 4.9.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 6.3.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 5.1.
Pimephales type Yolk-sac 5.5.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 7.8.
CYPRINIDAE sp. Yolk-sac 7.0.
CYPRINIDAE sp. Yolk-sac 5.5.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 6.1.
CYPRINIDAE sp. Yolk-sac 5.8.
CYPRINIDAE sp. Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 6.4.
CYPRINIDAE sp. Yolk-sac 7.1.
CYPRINIDAE sp. Yolk-sac 6.4.
CYPRINIDAE sp. Yolk-sac 6.3.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 5.1.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 5.1.
CYPRINIDAE sp. Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 3.0.
CYPRINIDAE sp. Yolk-sac 2.6.
CYPRINIDAE sp. Yolk-sac 2.5.
CYPRINIDAE sp. Yolk-sac 2.4.
CYPRINIDAE sp. Yolk-sac 2.8.
CYPRINIDAE sp. Yolk-sac 2.6.
D-43 DRAFT
APPENDIX D (cont.)
CYPRINIDAE sp. Yolk-sac 1.8.
CYPRINIDAE sp. Yolk-sac 2.8.
CYPRINIDAE sp. Yolk-sac 1.3.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 6.8.
ICTIOBINAE sp. Yolk-sac 7.5.
PUMPKINSEED type Post Yolk-sac 8.4.
PUMPKINSEED type Post Yolk-sac 8.1.
PUMPKINSEED type Yolk-sac 5.2.
Sander sp. Yolk-sac 5.1.
DARTER sp. Post Yolk-sac 12.2.
DARTER sp. Post Yolk-sac 7.8.
DARTER sp. Post Yolk-sac 6.9.
DARTER sp. Post Yolk-sac 8.2.
DARTER sp. Yolk-sac 5.7.
DARTER sp. Post Yolk-sac 7.0.
FRESHWATER DRUM Post Yolk-sac 10.1.
FRESHWATER DRUM Post Yolk-sac 15.8.
SAMPLE DATE: 17 June START DATE and TIME: 17JUN14:21:04 SAMPLE DURATION (minutes): 15.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.013972 STUDY GRAB TEMPERATURE (F): 77.2 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.4 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 15-21 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 6.3.
Dorosoma sp. Post Yolk-sac 8.4.
Dorosoma sp. Post Yolk-sac 12.7.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.2.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.0.
COMMON CARP Egg 1.3.
Pimephales type Yolk-sac 5.1.
Pimephales type Yolk-sac 4.9.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 4.9.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 6.1.
Pimephales type Yolk-sac 4.9.
Pimephales type Yolk-sac 4.8.
Pimephales type Yolk-sac. 5 Pimephales type Yolk-sac. 30 CYPRINIDAE sp. Yolk-sac 6.7.
CYPRINIDAE sp. Yolk-sac 4.9.
CYPRINIDAE sp. Yolk-sac 4.4.
CYPRINIDAE sp. Yolk-sac 6.4.
CYPRINIDAE sp. Yolk-sac 6.8.
CYPRINIDAE sp. Yolk-sac 5.8.
CYPRINIDAE sp. Yolk-sac 6.3.
CYPRINIDAE sp. Yolk-sac 4.9.
CYPRINIDAE sp. Yolk-sac 5.1.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 6.1.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 6.5.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 5.4.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 2.6.
CYPRINIDAE sp. Yolk-sac 2.4.
CYPRINIDAE sp. Yolk-sac 1.4.
Moxostoma sp. Post Yolk-sac 13.3.
Moxostoma sp. Post Yolk-sac 12.7.
ICTIOBINAE sp. Yolk-sac 7.0.
ICTIOBINAE sp. Yolk-sac 7.1.
ICTIOBINAE sp. Yolk-sac 6.8.
ICTIOBINAE sp. Yolk-sac 7.6.
DARTER sp. Yolk-sac 8.1.
DARTER sp. Post Yolk-sac 15.1.
DARTER sp. Post Yolk-sac 14.0.
FRESHWATER DRUM Egg 1.3.
ROUND GOBY Juvenile 7.7.
D-44 DRAFT
APPENDIX D (cont.)
ROUND GOBY Juvenile 7.5.
ROUND GOBY Juvenile 7.3.
ROUND GOBY Juvenile 6.7.
SAMPLE DATE: 17 June START DATE and TIME: 17JUN14:21:04 SAMPLE DURATION (minutes): 12.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.014803 STUDY GRAB TEMPERATURE (F): 77.2 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.4 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 15-21 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 10.9.
Dorosoma sp. Post Yolk-sac 10.6.
Dorosoma sp. Post Yolk-sac 10.2.
Dorosoma sp. Post Yolk-sac 7.3.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.2.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 6.1.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 4.9.
Pimephales type Yolk-sac 5.5.
Pimephales type Yolk-sac 5.1.
Pimephales type Yolk-sac 4.9.
Pimephales type Yolk-sac 4.5.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 6.1.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac. 15 CYPRINIDAE sp. Yolk-sac 6.4.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 5.8.
CYPRINIDAE sp. Yolk-sac 6.1.
CYPRINIDAE sp. Yolk-sac 6.3.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 6.7.
CYPRINIDAE sp. Yolk-sac 5.1.
CYPRINIDAE sp. Yolk-sac 6.6.
CYPRINIDAE sp. Yolk-sac 2.3.
CYPRINIDAE sp. Yolk-sac 2.6.
CYPRINIDAE sp. Yolk-sac 1.4.
CYPRINIDAE sp. Yolk-sac 2.6.
CYPRINIDAE sp. Yolk-sac 2.2.
CYPRINIDAE sp. Yolk-sac 2.6.
CYPRINIDAE sp. Yolk-sac 2.9.
CYPRINIDAE sp. Yolk-sac 2.5.
CYPRINIDAE sp. Yolk-sac 2.9.
Moxostoma sp. Post Yolk-sac 12.7.
Moxostoma sp. Post Yolk-sac 15.2.
ICTIOBINAE sp. Yolk-sac 7.7.
GREEN SUNFISH Juvenile 15.2.
PUMPKINSEED type Yolk-sac 5.1.
PUMPKINSEED type Yolk-sac 5.2.
DARTER sp. Yolk-sac 8.3.
DARTER sp. Post Yolk-sac 15.1.
DARTER sp. Post Yolk-sac 9.9.
FRESHWATER DRUM Yolk-sac 6.6.
ROUND GOBY Juvenile 7.4.
ROUND GOBY Juvenile 7.6.
ROUND GOBY Juvenile 7.6.
ROUND GOBY Juvenile 7.5.
ROUND GOBY Juvenile 8.1.
ROUND GOBY Juvenile 7.1.
ROUND GOBY Juvenile 7.3.
ROUND GOBY Juvenile 7.0.
D-45 DRAFT
APPENDIX D (cont.)
SAMPLE DATE: 24 June START DATE and TIME: 24JUN14:18:29 SAMPLE DURATION (minutes): 36.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.013515 STUDY GRAB TEMPERATURE (F): 77.5 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.2 FOREBAY CURRENT VELOCITY (ft/sec): 1.30 EXTRAPOLATION PERIOD: 22-30 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 777.6 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 12.8.
Dorosoma sp. Post Yolk-sac 13.4.
Dorosoma sp. Post Yolk-sac 10.6.
Dorosoma sp. Post Yolk-sac 13.8.
Dorosoma sp. Post Yolk-sac 11.2.
Dorosoma sp. Post Yolk-sac 12.2.
Dorosoma sp. Post Yolk-sac 9.8.
Dorosoma sp. Post Yolk-sac 7.5.
Dorosoma sp. Yolk-sac 3.7.
COMMON CARP Yolk-sac 6.1.
COMMON CARP Yolk-sac 6.0.
COMMON CARP Yolk-sac 6.4.
COMMON CARP Yolk-sac 6.7.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 5.1.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 5.3.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 6.1.
Pimephales type Yolk-sac 5.6.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 7.6.
CYPRINIDAE sp. Yolk-sac 5.1.
CYPRINIDAE sp. Yolk-sac 4.9.
CYPRINIDAE sp. Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 6.7.
CYPRINIDAE sp. Yolk-sac 4.2.
CYPRINIDAE sp. Yolk-sac 5.6.
CYPRINIDAE sp. Yolk-sac 5.6.
CYPRINIDAE sp. Yolk-sac 5.3.
PUMPKINSEED type Yolk-sac 5.5.
PUMPKINSEED type Yolk-sac 5.4.
DARTER sp. Yolk-sac 6.0.
DARTER sp. Yolk-sac 6.7.
FRESHWATER DRUM Post Yolk-sac 4.9.
FRESHWATER DRUM Egg 1.3.
UNIDENTIFIED Yolk-sac 3.1.
SAMPLE DATE: 24 June START DATE and TIME: 24JUN14:18:29 SAMPLE DURATION (minutes): 27.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.014211 STUDY GRAB TEMPERATURE (F): 77.5 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.2 FOREBAY CURRENT VELOCITY (ft/sec): 1.30 EXTRAPOLATION PERIOD: 22-30 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 777.6 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 5.4.
Dorosoma sp. Post Yolk-sac 10.4.
Dorosoma sp. Post Yolk-sac 9.7.
COMMON CARP Yolk-sac 7.1.
COMMON CARP Yolk-sac 7.1.
COMMON CARP Yolk-sac 5.3.
COMMON CARP Yolk-sac 6.0.
COMMON CARP Yolk-sac 5.5.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.2.
Hypophthalmichthys type Egg 3.2.
Hypophthalmichthys type Egg 3.7.
Hypophthalmichthys type Egg 2.1.
Hypophthalmichthys type Egg 3.8.
Hypophthalmichthys type Egg 3.8.
Hypophthalmichthys type Egg 3.4.
Hypophthalmichthys type Egg 3.6.
Hypophthalmichthys type Egg 2.8.
Hypophthalmichthys type Egg 2.9.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.5.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 6.1.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 6.2.
D-46 DRAFT
APPENDIX D (cont.)
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 5.5.
Pimephales type Yolk-sac 5.3.
Pimephales type Yolk-sac 5.5.
Pimephales type Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 5.0.
CYPRINIDAE sp. Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 5.3.
PUMPKINSEED type Yolk-sac 5.7.
DARTER sp. Post Yolk-sac 10.2.
FRESHWATER DRUM Egg 1.3.
SAMPLE DATE: 24 June START DATE and TIME: 24JUN14:19:17 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.013968 STUDY GRAB TEMPERATURE (F): 77.2 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.2 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 22-30 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 777.6 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 11.3.
Dorosoma sp. Post Yolk-sac 16.1.
COMMON CARP Yolk-sac 5.6.
Hypophthalmichthys type Egg 4.3.
Hypophthalmichthys type Egg 4.6.
Hypophthalmichthys type Egg 3.8.
Hypophthalmichthys type Egg 3.1.
Pimephales type Yolk-sac 6.3.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 6.8.
CYPRINIDAE sp. Yolk-sac 6.6.
CYPRINIDAE sp. Yolk-sac 5.3.
BLACKSTRIPE TOPMINNOW Yolk-sac 6.1.
DARTER sp. Yolk-sac 6.9.
SAMPLE DATE: 24 June START DATE and TIME: 24JUN14:19:17 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.013368 STUDY GRAB TEMPERATURE (F): 77.2 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.2 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 22-30 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 777.6 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 10.0.
Dorosoma sp. Post Yolk-sac 7.2.
Dorosoma sp. Post Yolk-sac 9.6.
Dorosoma sp. Post Yolk-sac 10.1.
COMMON CARP Yolk-sac 5.9.
Hypophthalmichthys type Egg 4.5.
Hypophthalmichthys type Egg 3.2.
Hypophthalmichthys type Egg 4.1.
Hypophthalmichthys type Egg 4.2.
Hypophthalmichthys type Egg 4.7.
Hypophthalmichthys type Egg 4.3.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 5.4.
CYPRINIDAE sp. Yolk-sac 6.4.
CYPRINIDAE sp. Yolk-sac 6.4.
DARTER sp. Yolk-sac 6.9.
FRESHWATER DRUM Egg 1.8.
SAMPLE DATE: 24 June START DATE and TIME: 24JUN14:21:41 SAMPLE DURATION (minutes): 21.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.013720 STUDY GRAB TEMPERATURE (F): 76.6 STUDY GRAB DISSOLVED OXYGEN (mg/L): 6.8 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 22-30 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 777.6 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 12.1.
Dorosoma sp. Post Yolk-sac 7.4.
Dorosoma sp. Post Yolk-sac 10.0.
Dorosoma sp. Post Yolk-sac 11.2.
Dorosoma sp. Post Yolk-sac 12.8.
Dorosoma sp. Post Yolk-sac 9.2.
Dorosoma sp. Post Yolk-sac 8.7.
Dorosoma sp. Post Yolk-sac 12.5.
Dorosoma sp. Post Yolk-sac 13.7.
COMMON CARP Yolk-sac 6.2.
COMMON CARP Yolk-sac 6.1.
D-47 DRAFT
APPENDIX D (cont.)
COMMON CARP Yolk-sac 7.4.
COMMON CARP Yolk-sac 5.8.
COMMON CARP Yolk-sac 6.3.
COMMON CARP Yolk-sac 6.8.
COMMON CARP Yolk-sac 6.8.
COMMON CARP Yolk-sac 6.3.
COMMON CARP Yolk-sac 7.9.
COMMON CARP Yolk-sac 8.2.
COMMON CARP Yolk-sac 6.0.
COMMON CARP Yolk-sac 5.9.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.3.
Hypophthalmichthys type Egg. 1 Hypophthalmichthys type Egg 4.0.
BLUNTNOSE MINNOW Juvenile 17.9.
Pimephales type Yolk-sac 4.7.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 5.1.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.3.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 5.1.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 5.1.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac. 37 CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 5.1.
CYPRINIDAE sp. Yolk-sac 6.6.
CYPRINIDAE sp. Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 5.4.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 6.5.
CYPRINIDAE sp. Yolk-sac 5.6.
CYPRINIDAE sp. Yolk-sac 5.0.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 6.7.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 5.8.
CYPRINIDAE sp. Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 6.5.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 5.4.
CYPRINIDAE sp. Yolk-sac 5.4.
CYPRINIDAE sp. Yolk-sac 5.4.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 6.7.
ICTIOBINAE sp. Yolk-sac 6.1.
ICTIOBINAE sp. Yolk-sac 7.2.
ICTIOBINAE sp. Yolk-sac 6.7.
ICTIOBINAE sp. Yolk-sac 6.1.
BLACKSTRIPE TOPMINNOW Juvenile 10.2.
PUMPKINSEED type Post Yolk-sac 10.0.
PUMPKINSEED type Yolk-sac 6.0.
PUMPKINSEED type Yolk-sac 3.7.
LOGPERCH type Yolk-sac 5.7.
DARTER sp. Yolk-sac 8.0.
FRESHWATER DRUM Post Yolk-sac 10.4.
FRESHWATER DRUM Post Yolk-sac 6.6.
FRESHWATER DRUM Post Yolk-sac 7.6.
FRESHWATER DRUM Post Yolk-sac 8.7.
FRESHWATER DRUM Post Yolk-sac 9.7.
FRESHWATER DRUM Post Yolk-sac 6.7.
ROUND GOBY Juvenile 6.8.
D-48 DRAFT
APPENDIX D (cont.)
SAMPLE DATE: 24 June START DATE and TIME: 24JUN14:21:41 SAMPLE DURATION (minutes): 21.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.023002 STUDY GRAB TEMPERATURE (F): 76.6 STUDY GRAB DISSOLVED OXYGEN (mg/L): 6.8 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 22-30 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 777.6 LIFE PLUS TAXA STAGE LENGTH COUNT GIZZARD SHAD Juvenile 21.2.
GIZZARD SHAD Juvenile 21.0.
GIZZARD SHAD Juvenile 18.7.
Dorosoma sp. Post Yolk-sac 15.2.
Dorosoma sp. Post Yolk-sac 6.8.
Dorosoma sp. Post Yolk-sac 8.7.
Dorosoma sp. Post Yolk-sac 8.2.
Dorosoma sp. Post Yolk-sac 8.0.
Dorosoma sp. Post Yolk-sac 10.0.
Dorosoma sp. Post Yolk-sac 6.5.
Dorosoma sp. Post Yolk-sac 10.1.
COMMON CARP Yolk-sac 5.7.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 6.7.
COMMON CARP Yolk-sac 6.2.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 5.9.
COMMON CARP Yolk-sac 7.2.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 7.5.
COMMON CARP Yolk-sac 6.0.
COMMON CARP Yolk-sac 6.2.
COMMON CARP Yolk-sac 7.1.
COMMON CARP Yolk-sac 5.8.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 7.2.
COMMON CARP Yolk-sac 7.2.
COMMON CARP Yolk-sac 6.4.
COMMON CARP Yolk-sac 5.8.
COMMON CARP Yolk-sac 7.4.
COMMON CARP Yolk-sac 1.0.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.4.
Hypophthalmichthys type Egg 4.4.
Hypophthalmichthys type Egg 3.9.
Hypophthalmichthys type Egg 4.4.
Hypophthalmichthys type Egg 4.8.
Hypophthalmichthys type Egg 3.9.
BLUNTNOSE MINNOW Juvenile 24.1.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 4.8.
Pimephales type Yolk-sac 6.1.
Pimephales type Yolk-sac 5.1.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 5.1.
Pimephales type Yolk-sac 5.5.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 5.1.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.1.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 4.8.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac. 7 CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 5.6.
CYPRINIDAE sp. Yolk-sac 6.1.
CYPRINIDAE sp. Yolk-sac 5.8.
CYPRINIDAE sp. Yolk-sac 5.4.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 5.5.
ICTIOBINAE sp. Juvenile 19.8.
BROOK SILVERSIDE Yolk-sac 5.2.
PUMPKINSEED type Yolk-sac 5.2.
PUMPKINSEED type Yolk-sac 4.9.
Lepomis sp. Post Yolk-sac 9.0.
Lepomis sp. Post Yolk-sac 15.6.
Lepomis sp. Post Yolk-sac 10.2.
LOGPERCH type Yolk-sac 6.2.
DARTER sp. Yolk-sac 6.5.
DARTER sp. Yolk-sac 6.2.
DARTER sp. Post Yolk-sac 11.2.
D-49 DRAFT
APPENDIX D (cont.)
FRESHWATER DRUM Post Yolk-sac 6.1.
FRESHWATER DRUM Post Yolk-sac 8.0.
ROUND GOBY Juvenile 7.3.
ROUND GOBY Juvenile 7.8.
ROUND GOBY Juvenile 9.0.
ROUND GOBY Juvenile 7.7.
ROUND GOBY Juvenile 7.7.
ROUND GOBY Juvenile 7.5.
SAMPLE DATE: 24 June START DATE and TIME: 24JUN14:22:17 SAMPLE DURATION (minutes): 14.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.015147 STUDY GRAB TEMPERATURE (F): 76.6 STUDY GRAB DISSOLVED OXYGEN (mg/L): 6.8 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 22-30 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 777.6 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 13.4.
Dorosoma sp. Post Yolk-sac 14.7.
COMMON CARP Yolk-sac 6.8.
COMMON CARP Yolk-sac 5.5.
COMMON CARP Yolk-sac 7.0.
COMMON CARP Yolk-sac 6.0.
COMMON CARP Yolk-sac 7.1.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 6.4.
Hypophthalmichthys type Egg 4.8.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 5.3.
Pimephales type Yolk-sac 5.3.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 6.1.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 4.8.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 4.9.
CYPRINIDAE sp. Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 7.0.
CYPRINIDAE sp. Yolk-sac 6.7.
CYPRINIDAE sp. Yolk-sac 6.5.
CYPRINIDAE sp. Yolk-sac 5.5.
CYPRINIDAE sp. Yolk-sac 6.1.
CYPRINIDAE sp. Yolk-sac 7.0.
CYPRINIDAE sp. Yolk-sac 5.6.
ICTIOBINAE sp. Juvenile 24.5.
BROOK SILVERSIDE Yolk-sac 5.6.
LARGEMOUTH BASS Juvenile 35.5.
LOGPERCH type Yolk-sac 5.5.
DARTER sp. Yolk-sac 7.0.
DARTER sp. Yolk-sac 8.4.
DARTER sp. Juvenile 13.1.
DARTER sp. Juvenile 13.7.
DARTER sp. Post Yolk-sac 10.3.
FRESHWATER DRUM Post Yolk-sac 7.7.
FRESHWATER DRUM Post Yolk-sac 7.9.
FRESHWATER DRUM Post Yolk-sac 11.3.
ROUND GOBY Juvenile 8.0.
ROUND GOBY Juvenile 14.5.
ROUND GOBY Juvenile 15.5.
SAMPLE DATE: 24 June START DATE and TIME: 24JUN14:22:17 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.014204 STUDY GRAB TEMPERATURE (F): 76.6 STUDY GRAB DISSOLVED OXYGEN (mg/L): 6.8 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 22-30 June MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 777.6 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 9.6.
Dorosoma sp. Post Yolk-sac 10.4.
Dorosoma sp. Post Yolk-sac 14.3.
COMMON CARP Yolk-sac 6.5.
COMMON CARP Yolk-sac 6.3.
COMMON CARP Yolk-sac 5.3.
COMMON CARP Yolk-sac 5.7.
COMMON CARP Yolk-sac 6.4.
COMMON CARP Yolk-sac 7.2.
COMMON CARP Yolk-sac 7.6.
COMMON CARP Yolk-sac 6.1.
Hypophthalmichthys type Egg 4.8.
Hypophthalmichthys type Egg 4.2.
Hypophthalmichthys type Egg. 1 Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 5.5.
Pimephales type Yolk-sac 4.4.
Pimephales type Yolk-sac 4.7.
D-50 DRAFT
APPENDIX D (cont.)
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 5.1.
CYPRINIDAE sp. Yolk-sac 6.4.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 5.4.
ICTIOBINAE sp. Post Yolk-sac 13.4.
PUMPKINSEED type Yolk-sac 5.5.
PUMPKINSEED type Yolk-sac 4.8.
LOGPERCH type Yolk-sac 6.0.
DARTER sp. Post Yolk-sac 13.0.
FRESHWATER DRUM Juvenile 26.1.
FRESHWATER DRUM Post Yolk-sac 13.2.
FRESHWATER DRUM Post Yolk-sac 5.2.
ROUND GOBY Juvenile 7.6.
ROUND GOBY Juvenile 13.0.
SAMPLE DATE: 9 July START DATE and TIME: 09JUL14:18:08 SAMPLE DURATION (minutes): 22.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.013343 STUDY GRAB TEMPERATURE (F): 80.1 STUDY GRAB DISSOLVED OXYGEN (mg/L): 9.0 FOREBAY CURRENT VELOCITY (ft/sec): 1.10 EXTRAPOLATION PERIOD: 1-12 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1036.8 LIFE PLUS TAXA STAGE LENGTH COUNT Lepomis sp. Post Yolk-sac 7.6.
LOGPERCH type Yolk-sac 6.2.
DARTER sp. Yolk-sac 8.6.
SAMPLE DATE: 9 July START DATE and TIME: 09JUL14:18:08 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.015999 STUDY GRAB TEMPERATURE (F): 80.1 STUDY GRAB DISSOLVED OXYGEN (mg/L): 9.0 FOREBAY CURRENT VELOCITY (ft/sec): 1.10 EXTRAPOLATION PERIOD: 1-12 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1036.8 LIFE PLUS TAXA STAGE LENGTH COUNT GIZZARD SHAD Juvenile 36.0.
Hypophthalmichthys type Egg 3.2.
SAMPLE DATE: 9 July START DATE and TIME: 09JUL14:18:40 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.014534 STUDY GRAB TEMPERATURE (F): 80.1 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.9 FOREBAY CURRENT VELOCITY (ft/sec): 1.40 EXTRAPOLATION PERIOD: 1-12 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1036.8 LIFE PLUS TAXA STAGE LENGTH COUNT COMMON CARP Egg 1.4.
Hypophthalmichthys type Egg 2.8.
Hypophthalmichthys type Egg 2.6.
SAMPLE DATE: 9 July START DATE and TIME: 09JUL14:18:40 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.015402 STUDY GRAB TEMPERATURE (F): 80.1 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.9 FOREBAY CURRENT VELOCITY (ft/sec): 1.40 EXTRAPOLATION PERIOD: 1-12 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1036.8 LIFE PLUS TAXA STAGE LENGTH COUNT COMMON CARP Egg 1.3.
Hypophthalmichthys type Egg 3.0.
Pimephales type Yolk-sac 5.6.
ICTIOBINAE sp. Yolk-sac 6.0.
SAMPLE DATE: 9 July START DATE and TIME: 09JUL14:21:31 SAMPLE DURATION (minutes): 14.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.018442 STUDY GRAB TEMPERATURE (F): 79.0 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.1 FOREBAY CURRENT VELOCITY (ft/sec): 0.90 EXTRAPOLATION PERIOD: 1-12 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1036.8 LIFE PLUS TAXA STAGE LENGTH COUNT GAR sp. Post Yolk-sac 25.2.
GAR sp. Post Yolk-sac 26.1.
Dorosoma sp. Post Yolk-sac 17.1.
Dorosoma sp. Post Yolk-sac 8.5.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 5.3.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 6.0.
D-51 DRAFT
APPENDIX D (cont.)
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 4.9.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 5.0.
Pimephales type Post Yolk-sac 6.0.
Pimephales type Post Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 6.3.
CYPRINIDAE sp. Yolk-sac 6.7.
CYPRINIDAE sp. Yolk-sac 4.7.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 5.1.
CYPRINIDAE sp. Yolk-sac 5.1.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 6.3.
CYPRINIDAE sp. Yolk-sac 5.6.
CYPRINIDAE sp. Yolk-sac 6.2.
ICTIOBINAE sp. Yolk-sac 6.2.
ICTIOBINAE sp. Yolk-sac 6.7.
PUMPKINSEED type Post Yolk-sac 8.1.
PUMPKINSEED type Post Yolk-sac 7.2.
FRESHWATER DRUM Egg 1.2.
ROUND GOBY Juvenile 6.9.
ROUND GOBY Juvenile 7.3.
ROUND GOBY Juvenile 6.7.
ROUND GOBY Juvenile 6.8.
ROUND GOBY Juvenile 6.7.
ROUND GOBY Juvenile 7.0.
ROUND GOBY Juvenile 6.9.
ROUND GOBY Juvenile 7.0.
ROUND GOBY Juvenile 6.8.
SAMPLE DATE: 9 July START DATE and TIME: 09JUL14:21:31 SAMPLE DURATION (minutes): 14.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.017087 STUDY GRAB TEMPERATURE (F): 79.0 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.1 FOREBAY CURRENT VELOCITY (ft/sec): 0.90 EXTRAPOLATION PERIOD: 1-12 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1036.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 12.2.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 6.4.
Pimephales type Yolk-sac 6.4.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 6.7.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 6.5.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 6.3.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 6.7.
CHANNEL CATFISH Juvenile 18.0.
CHANNEL CATFISH Juvenile 17.6.
CHANNEL CATFISH Juvenile 16.0.
FRESHWATER DRUM Egg 1.5.
ROUND GOBY Juvenile 7.5.
ROUND GOBY Juvenile 7.4.
ROUND GOBY Juvenile 7.6.
ROUND GOBY Juvenile 7.2.
SAMPLE DATE: 9 July START DATE and TIME: 09JUL14:21:55 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.014709 STUDY GRAB TEMPERATURE (F): 79.0 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.0 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 1-12 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1036.8 LIFE PLUS TAXA STAGE LENGTH COUNT COMMON CARP Egg 1.4.
Pimephales type Yolk-sac 6.4.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 5.8.
CYPRINIDAE sp. Yolk-sac 6.6.
CHANNEL CATFISH Juvenile 17.0.
PUMPKINSEED type Juvenile 13.8.
PUMPKINSEED type Juvenile 14.7.
D-52 DRAFT
APPENDIX D (cont.)
FRESHWATER DRUM Egg 1.6.
FRESHWATER DRUM Egg 1.5.
ROUND GOBY Juvenile 6.9.
ROUND GOBY Juvenile 7.3.
ROUND GOBY Juvenile 7.1.
ROUND GOBY Juvenile 7.8.
ROUND GOBY Juvenile 7.2.
ROUND GOBY Juvenile 8.5.
ROUND GOBY Juvenile 6.9.
ROUND GOBY Juvenile 7.0.
ROUND GOBY Juvenile 7.4.
ROUND GOBY Juvenile 7.5.
ROUND GOBY Juvenile 7.5.
ROUND GOBY Juvenile 7.7.
ROUND GOBY Juvenile 7.4.
SAMPLE DATE: 9 July START DATE and TIME: 09JUL14:21:55 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.015056 STUDY GRAB TEMPERATURE (F): 79.0 STUDY GRAB DISSOLVED OXYGEN (mg/L): 8.0 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 1-12 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1036.8 LIFE PLUS TAXA STAGE LENGTH COUNT COMMON CARP Yolk-sac 5.8.
Pimephales type Yolk-sac 5.5.
ICTIOBINAE sp. Yolk-sac 6.8.
FRESHWATER DRUM Yolk-sac 4.9.
ROUND GOBY Juvenile 7.2.
ROUND GOBY Juvenile 7.5.
ROUND GOBY Juvenile 7.2.
SAMPLE DATE: 15 July START DATE and TIME: 15JUL14:18:03 SAMPLE DURATION (minutes): 12.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.013773 STUDY GRAB TEMPERATURE (F): 75.2 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.6 FOREBAY CURRENT VELOCITY (ft/sec): 1.60 EXTRAPOLATION PERIOD: 13-19 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT COMMON CARP Egg 1.4.
COMMON CARP Egg 1.1.
COMMON CARP Egg 1.4.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 5.1.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 6.2.
CATOSTOMIDAE sp. Yolk-sac 4.8.
SAMPLE DATE: 15 July START DATE and TIME: 15JUL14:18:03 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.013440 STUDY GRAB TEMPERATURE (F): 75.2 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.6 FOREBAY CURRENT VELOCITY (ft/sec): 1.60 EXTRAPOLATION PERIOD: 13-19 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT COMMON CARP Egg 1.2.
Pimephales type Yolk-sac 4.9.
CYPRINIDAE sp. Yolk-sac 5.6.
Lepomis sp. Yolk-sac 5.5.
FRESHWATER DRUM Egg 1.2.
SAMPLE DATE: 15 July START DATE and TIME: 15JUL14:18:30 SAMPLE DURATION (minutes): 12.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.014907 STUDY GRAB TEMPERATURE (F): 75.0 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.6 FOREBAY CURRENT VELOCITY (ft/sec): 1.60 EXTRAPOLATION PERIOD: 13-19 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 9.3.
Dorosoma sp. Post Yolk-sac 7.8.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.4.
Pimephales type Yolk-sac 6.5.
Pimephales type Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 4.7.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 5.2.
FRESHWATER DRUM Yolk-sac 5.4.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.5.
D-53 DRAFT
APPENDIX D (cont.)
SAMPLE DATE: 15 July START DATE and TIME: 15JUL14:18:30 SAMPLE DURATION (minutes): 12.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.016430 STUDY GRAB TEMPERATURE (F): 75.0 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.6 FOREBAY CURRENT VELOCITY (ft/sec): 1.60 EXTRAPOLATION PERIOD: 13-19 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT COMMON CARP Egg 1.4.
COMMON CARP Egg 1.3.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.5.
COMMON CARP Egg 1.4.
COMMON CARP Egg 1.3.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 5.3.
Pimephales type Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 6.7.
CYPRINIDAE sp. Yolk-sac 5.6.
CYPRINIDAE sp. Yolk-sac 4.9.
CYPRINIDAE sp. Yolk-sac 4.7.
FRESHWATER DRUM Yolk-sac 5.4.
SAMPLE DATE: 15 July START DATE and TIME: 15JUL14:21:37 SAMPLE DURATION (minutes): 12.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.014132 STUDY GRAB TEMPERATURE (F): 74.5 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.3 FOREBAY CURRENT VELOCITY (ft/sec): 1.40 EXTRAPOLATION PERIOD: 13-19 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT GIZZARD SHAD Juvenile 24.1.
Dorosoma sp. Post Yolk-sac 10.3.
COMMON CARP Yolk-sac 6.2.
COMMON CARP Yolk-sac 7.0.
COMMON CARP Yolk-sac 7.0.
COMMON CARP Yolk-sac 6.6.
COMMON CARP Egg 1.5.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 4.8.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 4.8.
Pimephales type Yolk-sac 4.8.
Pimephales type Yolk-sac 6.1.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac. 18 CYPRINIDAE sp. Yolk-sac 6.4.
CYPRINIDAE sp. Yolk-sac 6.5.
CYPRINIDAE sp. Yolk-sac 6.5.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 6.6.
CYPRINIDAE sp. Yolk-sac 6.4.
CYPRINIDAE sp. Yolk-sac 5.1.
CYPRINIDAE sp. Yolk-sac 5.6.
CYPRINIDAE sp. Yolk-sac 6.4.
CYPRINIDAE sp. Yolk-sac 6.1.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 5.1.
CYPRINIDAE sp. Yolk-sac 6.7.
CYPRINIDAE sp. Yolk-sac 5.4.
CHANNEL CATFISH Juvenile 16.0.
BANDED KILLIFISH Juvenile 17.5.
PUMPKINSEED type Yolk-sac 5.8.
PUMPKINSEED type Yolk-sac 5.8.
PUMPKINSEED type Yolk-sac 4.8.
PUMPKINSEED type Yolk-sac 6.0.
Lepomis sp. Post Yolk-sac 10.7.
Lepomis sp. Post Yolk-sac 8.8.
Lepomis sp. Juvenile 15.0.
Lepomis sp. Juvenile 15.3.
Lepomis sp. Juvenile 16.2.
Lepomis sp. Juvenile 16.4.
ROUND GOBY Juvenile 6.7.
D-54 DRAFT
APPENDIX D (cont.)
SAMPLE DATE: 15 July START DATE and TIME: 15JUL14:21:37 SAMPLE DURATION (minutes): 15.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.013992 STUDY GRAB TEMPERATURE (F): 74.5 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.3 FOREBAY CURRENT VELOCITY (ft/sec): 1.40 EXTRAPOLATION PERIOD: 13-19 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 9.7.
COMMON CARP Yolk-sac 7.3.
COMMON CARP Juvenile 29.0.
COMMON CARP Egg 1.7.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 4.9.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 5.5.
Pimephales type Yolk-sac 4.4.
Pimephales type Yolk-sac 4.8.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 6.5.
Pimephales type Yolk-sac 5.3.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 5.5.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.5.
Pimephales type Yolk-sac 4.8.
Pimephales type Yolk-sac 5.6.
CYPRINIDAE sp. Yolk-sac 6.4.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 5.8.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 6.0.
CHANNEL CATFISH Juvenile 16.9.
CHANNEL CATFISH Juvenile 18.7.
CHANNEL CATFISH Juvenile 15.4.
CHANNEL CATFISH Juvenile 16.8.
Lepomis sp. Juvenile 10.4.
Lepomis sp. Juvenile 13.2.
Lepomis sp. Juvenile 14.0.
Lepomis sp. Juvenile 14.2.
Lepomis sp. Juvenile 13.9.
DARTER sp. Post Yolk-sac 10.3.
ROUND GOBY Juvenile 7.8.
ROUND GOBY Juvenile 7.6.
SAMPLE DATE: 15 July START DATE and TIME: 15JUL14:22:11 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.016009 STUDY GRAB TEMPERATURE (F): 74.3 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.3 FOREBAY CURRENT VELOCITY (ft/sec): 1.40 EXTRAPOLATION PERIOD: 13-19 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 8.2.
COMMON CARP Egg 1.1.
COMMON CARP Egg 1.1.
Pimephales type Yolk-sac 4.8.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.3.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 5.3.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 4.7.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac. 1 Pimephales type Yolk-sac. 3 CYPRINIDAE sp. Yolk-sac 6.7.
CYPRINIDAE sp. Yolk-sac 5.4.
CYPRINIDAE sp. Yolk-sac 6.1.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 6.5.
CYPRINIDAE sp. Yolk-sac 6.0.
D-55 DRAFT
APPENDIX D (cont.)
CYPRINIDAE sp. Yolk-sac 5.9.
CYPRINIDAE sp. Yolk-sac 6.2.
CHANNEL CATFISH Juvenile 15.6.
CHANNEL CATFISH Juvenile 16.1.
PUMPKINSEED type Yolk-sac 4.6.
PUMPKINSEED type Yolk-sac 5.4.
PUMPKINSEED type Yolk-sac 5.2.
PUMPKINSEED type Yolk-sac 5.1.
Lepomis sp. Juvenile 14.1.
Lepomis sp. Juvenile 11.2.
SAMPLE DATE: 15 July START DATE and TIME: 15JUL14:22:11 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.017717 STUDY GRAB TEMPERATURE (F): 74.3 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.3 FOREBAY CURRENT VELOCITY (ft/sec): 1.40 EXTRAPOLATION PERIOD: 13-19 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 8.9.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 6.1.
Pimephales type Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 7.2.
CHANNEL CATFISH Juvenile 10.2.
CHANNEL CATFISH Juvenile 10.4.
CHANNEL CATFISH Juvenile 10.6.
CHANNEL CATFISH Juvenile 12.7.
CHANNEL CATFISH Juvenile 10.6.
PUMPKINSEED type Yolk-sac 5.6.
PUMPKINSEED type Yolk-sac 4.7.
Lepomis sp. Juvenile 9.6.
Lepomis sp. Juvenile 10.6.
Lepomis sp. Juvenile 11.0.
Lepomis sp. Juvenile 10.0.
Lepomis sp. Juvenile 15.5.
Lepomis sp. Juvenile 14.8.
Lepomis sp. Juvenile 16.2.
Lepomis sp. Juvenile 18.3.
LOGPERCH type Yolk-sac 6.2.
LOGPERCH type Yolk-sac 6.3.
LOGPERCH type Yolk-sac 5.6.
FRESHWATER DRUM Egg 1.5.
FRESHWATER DRUM Egg 1.6.
SAMPLE DATE: 22 July START DATE and TIME: 22JUL14:18:11 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.014226 STUDY GRAB TEMPERATURE (F): 83.3 STUDY GRAB DISSOLVED OXYGEN (mg/L): 10.5 FOREBAY CURRENT VELOCITY (ft/sec): 1.60 EXTRAPOLATION PERIOD: 20-26 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Pimephales type Yolk-sac 4.8.
FRESHWATER DRUM Yolk-sac 4.2.
FRESHWATER DRUM Yolk-sac 3.2.
FRESHWATER DRUM Yolk-sac 4.2.
UNIDENTIFIED Yolk-sac 2.7.
UNIDENTIFIED Yolk-sac 2.9.
SAMPLE DATE: 22 July START DATE and TIME: 22JUL14:18:11 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.015016 STUDY GRAB TEMPERATURE (F): 83.3 STUDY GRAB DISSOLVED OXYGEN (mg/L): 10.5 FOREBAY CURRENT VELOCITY (ft/sec): 1.60 EXTRAPOLATION PERIOD: 20-26 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Pimephales type Yolk-sac 3.8.
UNIDENTIFIED Egg 1.2.
SAMPLE DATE: 22 July START DATE and TIME: 22JUL14:18:34 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.013453 STUDY GRAB TEMPERATURE (F): 82.9 STUDY GRAB DISSOLVED OXYGEN (mg/L): 10.4 FOREBAY CURRENT VELOCITY (ft/sec): 1.60 EXTRAPOLATION PERIOD: 20-26 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 5.6.
CYPRINIDAE sp. Yolk-sac 6.6.
D-56 DRAFT
APPENDIX D (cont.)
FRESHWATER DRUM Yolk-sac 3.8.
UNIDENTIFIED Egg 1.3.
UNIDENTIFIED Egg 1.4.
UNIDENTIFIED Egg 1.4.
SAMPLE DATE: 22 July START DATE and TIME: 22JUL14:18:34 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.014740 STUDY GRAB TEMPERATURE (F): 82.9 STUDY GRAB DISSOLVED OXYGEN (mg/L): 10.4 FOREBAY CURRENT VELOCITY (ft/sec): 1.60 EXTRAPOLATION PERIOD: 20-26 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Pimephales type Yolk-sac 5.0.
SAMPLE DATE: 22 July START DATE and TIME: 22JUL14:21:23 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.015126 STUDY GRAB TEMPERATURE (F): 82.6 STUDY GRAB DISSOLVED OXYGEN (mg/L): 9.4 FOREBAY CURRENT VELOCITY (ft/sec): 1.60 EXTRAPOLATION PERIOD: 20-26 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 6.3.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 5.1.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 6.3.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 6.7.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 5.0.
FRESHWATER DRUM Yolk-sac 3.6.
SAMPLE DATE: 22 July START DATE and TIME: 22JUL14:21:23 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.015126 STUDY GRAB TEMPERATURE (F): 82.6 STUDY GRAB DISSOLVED OXYGEN (mg/L): 9.4 FOREBAY CURRENT VELOCITY (ft/sec): 1.60 EXTRAPOLATION PERIOD: 20-26 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Pimephales type Yolk-sac 5.5.
Pimephales type Yolk-sac 6.4.
CYPRINIDAE sp. Yolk-sac 6.6.
CYPRINIDAE sp. Yolk-sac 6.5.
FRESHWATER DRUM Yolk-sac 3.1.
SAMPLE DATE: 22 July START DATE and TIME: 22JUL14:21:53 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.014890 STUDY GRAB TEMPERATURE (F): 82.4 STUDY GRAB DISSOLVED OXYGEN (mg/L): 9.1 FOREBAY CURRENT VELOCITY (ft/sec): 1.60 EXTRAPOLATION PERIOD: 20-26 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT NO ICHTHYOPLANKTON.. 0 SAMPLE DATE: 22 July START DATE and TIME: 22JUL14:21:53 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.013822 STUDY GRAB TEMPERATURE (F): 82.4 STUDY GRAB DISSOLVED OXYGEN (mg/L): 9.1 FOREBAY CURRENT VELOCITY (ft/sec): 1.60 EXTRAPOLATION PERIOD: 20-26 July MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 4.8.
Pimephales type Yolk-sac 5.1.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 6.1.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 5.4.
CYPRINIDAE sp. Yolk-sac 6.1.
D-57 DRAFT
APPENDIX D (cont.)
SAMPLE DATE: 29 July START DATE and TIME: 29JUL14:18:12 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.018102 STUDY GRAB TEMPERATURE (F): 80.4 STUDY GRAB DISSOLVED OXYGEN (mg/L): 11.0 FOREBAY CURRENT VELOCITY (ft/sec): 1.20 EXTRAPOLATION PERIOD: 27 July-2 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT CYPRINIDAE sp. Yolk-sac 5.5.
CYPRINIDAE sp. Yolk-sac 1.9.
CYPRINIDAE sp. Yolk-sac 2.7.
FRESHWATER DRUM Yolk-sac 2.5.
UNIDENTIFIED Egg 1.2.
SAMPLE DATE: 29 July START DATE and TIME: 29JUL14:18:12 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.014622 STUDY GRAB TEMPERATURE (F): 80.4 STUDY GRAB DISSOLVED OXYGEN (mg/L): 11.0 FOREBAY CURRENT VELOCITY (ft/sec): 1.20 EXTRAPOLATION PERIOD: 27 July-2 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT COMMON CARP Egg 1.2.
COMMON CARP Egg 1.3.
COMMON CARP Egg 1.2.
Pimephales type Yolk-sac 4.9.
CYPRINIDAE sp. Yolk-sac 5.3.
CYPRINIDAE sp. Yolk-sac 3.0.
ICTIOBINAE sp. Yolk-sac 8.2.
PUMPKINSEED type Yolk-sac 5.2.
UNIDENTIFIED Egg 1.2.
SAMPLE DATE: 29 July START DATE and TIME: 29JUL14:18:40 SAMPLE DURATION (minutes): 12.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.016894 STUDY GRAB TEMPERATURE (F): 79.5 STUDY GRAB DISSOLVED OXYGEN (mg/L): 10.6 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 27 July-2 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT CYPRINIDAE sp. Yolk-sac 6.8.
CYPRINIDAE sp. Yolk-sac 6.3.
CYPRINIDAE sp. Yolk-sac 6.4.
CYPRINIDAE sp. Yolk-sac 6.3.
SAMPLE DATE: 29 July START DATE and TIME: 29JUL14:18:40 SAMPLE DURATION (minutes): 12.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.016752 STUDY GRAB TEMPERATURE (F): 79.5 STUDY GRAB DISSOLVED OXYGEN (mg/L): 10.6 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 27 July-2 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT COMMON CARP Egg 1.4.
COMMON CARP Egg 1.3.
CYPRINIDAE sp. Yolk-sac 7.2.
SAMPLE DATE: 29 July START DATE and TIME: 29JUL14:21:15 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.018989 STUDY GRAB TEMPERATURE (F): 79.0 STUDY GRAB DISSOLVED OXYGEN (mg/L): 9.6 FOREBAY CURRENT VELOCITY (ft/sec): 1.60 EXTRAPOLATION PERIOD: 27 July-2 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 8.2.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 6.1.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 5.1.
Pimephales type Yolk-sac 6.7.
Pimephales type Yolk-sac 4.8.
Pimephales type Yolk-sac 5.5.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 4.9.
CYPRINIDAE sp. Yolk-sac 6.8.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 6.3.
CYPRINIDAE sp. Yolk-sac 6.4.
CYPRINIDAE sp. Yolk-sac 6.8.
CYPRINIDAE sp. Yolk-sac 7.5.
CYPRINIDAE sp. Yolk-sac 6.1.
PUMPKINSEED type Yolk-sac 5.7.
D-58 DRAFT
APPENDIX D (cont.)
SAMPLE DATE: 29 July START DATE and TIME: 29JUL14:21:15 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.016178 STUDY GRAB TEMPERATURE (F): 79.0 STUDY GRAB DISSOLVED OXYGEN (mg/L): 9.6 FOREBAY CURRENT VELOCITY (ft/sec): 1.60 EXTRAPOLATION PERIOD: 27 July-2 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 7.2.
COMMON CARP Yolk-sac 7.3.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 6.1.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 5.5.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 5.3.
Pimephales type Yolk-sac 4.9.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 5.8.
CYPRINIDAE sp. Yolk-sac 6.0.
CYPRINIDAE sp. Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 6.5.
CYPRINIDAE sp. Yolk-sac 6.4.
PUMPKINSEED type Yolk-sac 5.0.
SAMPLE DATE: 29 July START DATE and TIME: 29JUL14:21:41 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.019218 STUDY GRAB TEMPERATURE (F): 78.8 STUDY GRAB DISSOLVED OXYGEN (mg/L): 9.4 FOREBAY CURRENT VELOCITY (ft/sec): 1.60 EXTRAPOLATION PERIOD: 27 July-2 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Pimephales type Yolk-sac 5.5.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 4.5.
Pimephales type Yolk-sac 5.3.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 5.4.
CYPRINIDAE sp. Yolk-sac 7.2.
CYPRINIDAE sp. Yolk-sac 6.1.
CYPRINIDAE sp. Yolk-sac 6.1.
CYPRINIDAE sp. Yolk-sac 6.3.
CYPRINIDAE sp. Yolk-sac 5.0.
CYPRINIDAE sp. Yolk-sac 6.4.
CYPRINIDAE sp. Yolk-sac 6.9.
SAMPLE DATE: 29 July START DATE and TIME: 29JUL14:21:41 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.018993 STUDY GRAB TEMPERATURE (F): 78.8 STUDY GRAB DISSOLVED OXYGEN (mg/L): 9.4 FOREBAY CURRENT VELOCITY (ft/sec): 1.60 EXTRAPOLATION PERIOD: 27 July-2 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 604.8 LIFE PLUS TAXA STAGE LENGTH COUNT Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.3.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 5.1.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 6.2.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 4.9.
Pimephales type Yolk-sac 6.2.
CYPRINIDAE sp. Yolk-sac 5.6.
CYPRINIDAE sp. Yolk-sac 6.4.
CYPRINIDAE sp. Yolk-sac 6.5.
CYPRINIDAE sp. Yolk-sac 6.4.
CYPRINIDAE sp. Yolk-sac 6.5.
CYPRINIDAE sp. Yolk-sac 6.1.
CYPRINIDAE sp. Yolk-sac 6.6.
CYPRINIDAE sp. Yolk-sac 7.1.
D-59 DRAFT
APPENDIX D (cont.)
SAMPLE DATE: 12 August START DATE and TIME: 12AUG14:18:03 SAMPLE DURATION (minutes): 8.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.014289 STUDY GRAB TEMPERATURE (F): 80.8 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.6 FOREBAY CURRENT VELOCITY (ft/sec): 1.60 EXTRAPOLATION PERIOD: 3-16 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1209.6 LIFE PLUS TAXA STAGE LENGTH COUNT Hypophthalmichthys type Egg 3.1.
UNIDENTIFIED Egg 1.8.
SAMPLE DATE: 12 August START DATE and TIME: 12AUG14:18:03 SAMPLE DURATION (minutes): 8.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.015501 STUDY GRAB TEMPERATURE (F): 80.8 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.6 FOREBAY CURRENT VELOCITY (ft/sec): 1.60 EXTRAPOLATION PERIOD: 3-16 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1209.6 LIFE PLUS TAXA STAGE LENGTH COUNT NO ICHTHYOPLANKTON.. 0 SAMPLE DATE: 12 August START DATE and TIME: 12AUG14:18:28 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.014557 STUDY GRAB TEMPERATURE (F): 80.8 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.9 FOREBAY CURRENT VELOCITY (ft/sec): 1.70 EXTRAPOLATION PERIOD: 3-16 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1209.6 LIFE PLUS TAXA STAGE LENGTH COUNT UNIDENTIFIED Yolk-sac 3.2.
UNIDENTIFIED Yolk-sac 3.1.
SAMPLE DATE: 12 August START DATE and TIME: 12AUG14:18:28 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.014343 STUDY GRAB TEMPERATURE (F): 80.8 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.9 FOREBAY CURRENT VELOCITY (ft/sec): 1.70 EXTRAPOLATION PERIOD: 3-16 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1209.6 LIFE PLUS TAXA STAGE LENGTH COUNT NO ICHTHYOPLANKTON.. 0 SAMPLE DATE: 12 August START DATE and TIME: 12AUG14:21:05 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.014348 STUDY GRAB TEMPERATURE (F): 80.4 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.3 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 3-16 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1209.6 LIFE PLUS TAXA STAGE LENGTH COUNT Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 4.3.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 5.0.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 5.4.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 5.8.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 4.8.
CYPRINIDAE sp. Yolk-sac 5.6.
CYPRINIDAE sp. Yolk-sac 7.6.
CYPRINIDAE sp. Yolk-sac 8.1.
CYPRINIDAE sp. Yolk-sac 6.6.
CYPRINIDAE sp. Yolk-sac 5.1.
CYPRINIDAE sp. Yolk-sac 5.7.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 6.3.
PUMPKINSEED type Yolk-sac 5.1.
SAMPLE DATE: 12 August START DATE and TIME: 12AUG14:21:05 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.013684 STUDY GRAB TEMPERATURE (F): 80.4 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.3 FOREBAY CURRENT VELOCITY (ft/sec): 1.50 EXTRAPOLATION PERIOD: 3-16 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1209.6 LIFE PLUS TAXA STAGE LENGTH COUNT Pimephales type Yolk-sac 4.6.
Pimephales type Yolk-sac 4.8.
Pimephales type Yolk-sac 5.7.
Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 4.7.
Pimephales type Yolk-sac 4.8.
D-60 DRAFT
APPENDIX D (cont.)
Pimephales type Yolk-sac 4.5.
Pimephales type Yolk-sac 4.8.
CYPRINIDAE sp. Yolk-sac 4.9.
CYPRINIDAE sp. Yolk-sac 4.8.
CYPRINIDAE sp. Yolk-sac 6.9.
CYPRINIDAE sp. Yolk-sac 7.0.
CYPRINIDAE sp. Yolk-sac 5.2.
CYPRINIDAE sp. Yolk-sac 6.7.
CYPRINIDAE sp. Yolk-sac 7.9.
CYPRINIDAE sp. Yolk-sac 6.3.
CYPRINIDAE sp. Yolk-sac 7.6.
CYPRINIDAE sp. Yolk-sac 6.5.
CYPRINIDAE sp. Yolk-sac 5.1.
SAMPLE DATE: 12 August START DATE and TIME: 12AUG14:21:32 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.014978 STUDY GRAB TEMPERATURE (F): 80.4 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.3 FOREBAY CURRENT VELOCITY (ft/sec): 1.60 EXTRAPOLATION PERIOD: 3-16 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1209.6 LIFE PLUS TAXA STAGE LENGTH COUNT Dorosoma sp. Post Yolk-sac 5.8.
Pimephales type Yolk-sac 4.8.
CYPRINIDAE sp. Post Yolk-sac 9.3.
CYPRINIDAE sp. Post Yolk-sac 7.9.
CYPRINIDAE sp. Post Yolk-sac 10.0.
CYPRINIDAE sp. Post Yolk-sac 6.2.
CYPRINIDAE sp. Post Yolk-sac 11.6.
CYPRINIDAE sp. Post Yolk-sac 10.5.
CYPRINIDAE sp. Post Yolk-sac 10.5.
CYPRINIDAE sp. Post Yolk-sac 7.8.
CYPRINIDAE sp. Post Yolk-sac 7.7.
CYPRINIDAE sp. Post Yolk-sac 13.6.
CYPRINIDAE sp. Post Yolk-sac 5.0.
SAMPLE DATE: 12 August START DATE and TIME: 12AUG14:21:32 SAMPLE DURATION (minutes): 10.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.015262 STUDY GRAB TEMPERATURE (F): 80.4 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.3 FOREBAY CURRENT VELOCITY (ft/sec): 1.60 EXTRAPOLATION PERIOD: 3-16 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1209.6 LIFE PLUS TAXA STAGE LENGTH COUNT Pimephales type Yolk-sac 5.6.
Pimephales type Yolk-sac 5.2.
Pimephales type Yolk-sac 6.0.
Pimephales type Yolk-sac 5.9.
Pimephales type Yolk-sac 5.1.
Pimephales type Yolk-sac 5.1.
CYPRINIDAE sp. Post Yolk-sac 8.7.
CYPRINIDAE sp. Post Yolk-sac 9.5.
CYPRINIDAE sp. Post Yolk-sac 7.1.
CYPRINIDAE sp. Yolk-sac 4.6.
PUMPKINSEED type Yolk-sac 6.7.
SAMPLE DATE: 26 August START DATE and TIME: 26AUG14:16:30 SAMPLE DURATION (minutes): 25.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.015189 STUDY GRAB TEMPERATURE (F): 81.1 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.1 FOREBAY CURRENT VELOCITY (ft/sec): 1.30 EXTRAPOLATION PERIOD: 17-30 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1209.6 LIFE PLUS TAXA STAGE LENGTH COUNT NO ICHTHYOPLANKTON.. 0 SAMPLE DATE: 26 August START DATE and TIME: 26AUG14:16:30 SAMPLE DURATION (minutes): 25.00 DIEL PERIOD: Day DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.014638 STUDY GRAB TEMPERATURE (F): 81.1 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.1 FOREBAY CURRENT VELOCITY (ft/sec): 1.30 EXTRAPOLATION PERIOD: 17-30 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1209.6 LIFE PLUS TAXA STAGE LENGTH COUNT Notropis sp. Juvenile 18.3.
SAMPLE DATE: 26 August START DATE and TIME: 26AUG14:17:19 SAMPLE DURATION (minutes): 15.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.019048 STUDY GRAB TEMPERATURE (F): 80.8 STUDY GRAB DISSOLVED OXYGEN (mg/L): 6.9 FOREBAY CURRENT VELOCITY (ft/sec): 1.60 EXTRAPOLATION PERIOD: 17-30 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1209.6 LIFE PLUS TAXA STAGE LENGTH COUNT CYPRINIDAE sp. Yolk-sac 5.8.
CYPRINIDAE sp. Yolk-sac 3.1.
D-61 DRAFT
APPENDIX D (cont.)
SAMPLE DATE: 26 August START DATE and TIME: 26AUG14:17:12 SAMPLE DURATION (minutes): 15.00 DIEL PERIOD: Day DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.015857 STUDY GRAB TEMPERATURE (F): 80.8 STUDY GRAB DISSOLVED OXYGEN (mg/L): 6.9 FOREBAY CURRENT VELOCITY (ft/sec): 1.60 EXTRAPOLATION PERIOD: 17-30 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1209.6 LIFE PLUS TAXA STAGE LENGTH COUNT NO ICHTHYOPLANKTON.. 0 SAMPLE DATE: 26 August START DATE and TIME: 26AUG14:20:37 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.013773 STUDY GRAB TEMPERATURE (F): 80.6 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.0 FOREBAY CURRENT VELOCITY (ft/sec): 1.20 EXTRAPOLATION PERIOD: 17-30 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1209.6 LIFE PLUS TAXA STAGE LENGTH COUNT Notropis sp. Juvenile 13.6.
Notropis sp. Juvenile 11.7.
Pimephales type Yolk-sac 5.2.
SAMPLE DATE: 26 August START DATE and TIME: 26AUG14:20:37 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Night DEPTH: SUR REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.013993 STUDY GRAB TEMPERATURE (F): 80.6 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.0 FOREBAY CURRENT VELOCITY (ft/sec): 1.20 EXTRAPOLATION PERIOD: 17-30 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1209.6 LIFE PLUS TAXA STAGE LENGTH COUNT BULLHEAD MINNOW Juvenile 25.1.
BULLHEAD MINNOW Juvenile 12.2.
PUMPKINSEED type Post Yolk-sac 9.1.
SAMPLE DATE: 26 August START DATE and TIME: 26AUG14:21:08 SAMPLE DURATION (minutes): 11.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: A VOLUME SAMPLED (gals x 10^6): 0.013304 STUDY GRAB TEMPERATURE (F): 80.6 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.0 FOREBAY CURRENT VELOCITY (ft/sec): 1.35 EXTRAPOLATION PERIOD: 17-30 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1209.6 LIFE PLUS TAXA STAGE LENGTH COUNT Notropis sp. Juvenile 12.1.
SAMPLE DATE: 26 August START DATE and TIME: 26AUG14:21:08 SAMPLE DURATION (minutes): 13.00 DIEL PERIOD: Night DEPTH: BOT REPLICATE: B VOLUME SAMPLED (gals x 10^6): 0.014060 STUDY GRAB TEMPERATURE (F): 80.6 STUDY GRAB DISSOLVED OXYGEN (mg/L): 7.0 FOREBAY CURRENT VELOCITY (ft/sec): 1.35 EXTRAPOLATION PERIOD: 17-30 August MAKEUP WATER VOLUME FOR EXTRAPOLATION PERIOD (gals x 10^6): 1209.6 LIFE PLUS TAXA STAGE LENGTH COUNT Pimephales sp. Juvenile 9.8.
D-62 DRAFT