MONTHYEARTSTF-15-11, TSTF Comments on Draft Model Safety Evaluation of Traveler TSTF-545, TS Inservice Testing Program & Clarify SR Usage Rule Application to Section 5.5 Testing and Transmittal of TSTF-545, Revision 32015-10-21021 October 2015 TSTF Comments on Draft Model Safety Evaluation of Traveler TSTF-545, TS Inservice Testing Program & Clarify SR Usage Rule Application to Section 5.5 Testing and Transmittal of TSTF-545, Revision 3 Project stage: Draft Request ML15181A0452016-03-18018 March 2016 Fr Notice of Availability Model SE for Traveler TSTF-545, Rev. 3, TS Inservice Testing Program Removal & Clarify SR Usage Rule Application to Section 5.5 Testing Using the CLIIP Project stage: Other 05000272/LER-2016-0012016-07-0505 July 2016 Unanalyzed Condition due to Degraded Reactor Baffle to Former Bolts, LER 16-001-00 for Salem, Unit 1, Regarding Unanalyzed Condition due to Degraded Reactor Baffle to Former Bolts Project stage: Request LR-N16-0138, Extension for License Amendment Request to Revise Technical Specifications to Adopt TSTF-545, Revision 32016-07-27027 July 2016 Extension for License Amendment Request to Revise Technical Specifications to Adopt TSTF-545, Revision 3 Project stage: Request ML16218A0052016-08-11011 August 2016 Request for Additional Information Concerning Request for an Extension to Enforcement Guidance Memorandum 12-001 Project stage: RAI LR-N16-0153, Response to Request for Additional Information Concerning Request for an Extension to Enforcement Guidance Memorandum 12-0012016-08-18018 August 2016 Response to Request for Additional Information Concerning Request for an Extension to Enforcement Guidance Memorandum 12-001 Project stage: Response to RAI ML16235A4712016-08-26026 August 2016 Request for an Extension to Enforcement Guidance Memorandum 12-001 Project stage: Other 2016-07-05
[Table View] |
|
---|
Category:Federal Register Notice
MONTHYEARML17297B7742017-10-27027 October 2017 E-mail Attachment Oct 27 2006 Notice of Availabilty TSTF-484 ML15181A0452016-03-18018 March 2016 Fr Notice of Availability Model SE for Traveler TSTF-545, Rev. 3, TS Inservice Testing Program Removal & Clarify SR Usage Rule Application to Section 5.5 Testing Using the CLIIP ML13036A3712013-05-30030 May 2013 Federal Register Notice of Availability Models for Plant-Specific Adoption of TSTF 426, Revision 5, Revise or Add Actions to Preclude Entry Into LCO 3.0.3 - RITSTF Initiatives 6B & 6C, Using the Consolidated Line Item Improvement Process ML12355A7672013-02-14014 February 2013 Models for Plant-Specific Adoption of Technical Specifications Task Force Traveler TSTF 535, Revision 0, Revise Shutdown Margin Definition to Address Advanced Fuel Designs, Using the Consolidated Line Item Improvement Process ML12097A5992013-01-0707 January 2013 TSTF-426 NRC FRN Proposed Models for Plant-Specific Adoption of Technical Specifications Task Force Traveler TSTF-426, Revision 5, Revise or Add Actions to Preclude Entry Into LCO 3.0.3 - RITSTF Initiatives 6B & 6C. ML12314A4402012-11-0202 November 2012 FRN for Proposed Model Safety Evaluation for Plant-Specific Adoption of Technical Specifications Task Force Traveler TSTF-535, Revision 0 ML12158A4902012-09-12012 September 2012 Federal Register Notice - Model Safety Evaluation for Plant-Specific Adoption of Technical Specifications Task Force Traveler TSTF-522, Revision 0, Revise Ventilation System Surveillance Requirements to Operate for 10 Hours Per Month, ..... ML12072A1692012-05-0202 May 2012 FRN: Notice of Availability for TSTF-432, Revision 1, Change in Technical Specifications End States (WCAP-16294) Using the Consolidated Line Item Improvement Process ML1135402642012-03-14014 March 2012 Proposed Models for Plant-Specific Adoption of Technical Specifications Task Force Traveler TSTF-522, Rev. 0, Revise Ventilation System Surveillance Requirements to Operate for 10 Hours Per Month ML1109802602012-01-17017 January 2012 Notice for Comment on the Proposed Models for Plant-Specific Adoption of Traveler TSTF-432, Rev 1, Change in Technical Specifications End States (WCAP-16294) ML1126902032011-11-0606 November 2011 FRN: General Notice. Notice of Opportunity for Public Comment on the Proposed Model Safety Evaluation for Plant Specific Adoption of Technical Specifications Task Force Traveler TSTF-505, Revision 1, Provide Risk-Informed Extended Completio ML1132202272011-11-0606 November 2011 FRN: General Notice. Notice of Opportunity for Public Comment on the Proposed Model SE for Plant-Specific Adoption of TSTF Traveler TSTF-505, Revision 1, Provide Risk-Informed Extended Completion Times. ML1125504502011-10-25025 October 2011 FRN: Correction to NOA TSTF-500, Rev 2, DC Electrical Rewrite - Update to TSTF-360. ML1121016042011-10-19019 October 2011 FRN: Notice of Availability of Models for Plant-Specific Adoption of TSTF-510, Rev 2, Revision to Steam Generator Program Inspection Frequencies and Tube Sample Selection ML1109806822011-08-22022 August 2011 FRN: Notice of Availability of Proposed Models for Plant-Specific Adoption of Traveler TSTF-500, Rev. 2, DC Electrical Rewrite - Update to TSTF-360 ML1108003302011-06-0606 June 2011 FRN: Notice for Comment on Traveler TSTF-510, Revision 2, Revision to Steam Generator Program Inspection Frequencies and Tube Sample Selection. ML1032701592011-03-22022 March 2011 NOA of TSTF Traveler TSTF-422, Rev 2, Change in Technical Specifications End States (CE NPSD-1186), for CE Plants ML1027305852011-02-0202 February 2011 FRN: General Notice. Notice of Availability of the Proposed Models for Plant Specific Adoption of Technical Specifications Task Force (TSTF) Traveler TSTF-423, Revision 1, Technical Specifications End States, NEDC-32988-A, for Boiling Water ML1013402672010-12-20020 December 2010 Federal Register Notice, Notice of Availability of TSTF-513, Revision 3 ML1023007332010-12-0707 December 2010 Federal Register Notice, Notice of Availability of Model Application and Model Safety Evaluation for Plant-Specific Adoption of TSTF-514, Revision 3 ML1023103672010-11-23023 November 2010 FRN: General Notice. Notice of Availability for TSTF-431, Revision 3 ML1008500882010-05-14014 May 2010 FRN: General Notice. Nuclear Regulatory Commission Notice of Availability of the Models for Plant-Specific Adoption of Technical Specifications Task Force Traveler TSTF-501, Revision 1, Relocate Stored Fuel Oil and Lube Oil Vol TSTF-501 FRN ML0934105812010-04-30030 April 2010 Notice of Availability of the Proposed Models for Plant-Specific Adoption of TSTF-493, Rev. 4, Clarify Application of Setpoint Methodology for LSSS Functions. ML0933404112010-04-27027 April 2010 Notice of Opportunity for Public Comment on the Proposed Models for Plant Specific Adoption of TSTF-500, DC Electrical Rewrite - Update to TSTF-360 ML0933403602010-04-0505 April 2010 Notice of Opportunity for Comment on the Proposed Models TSTF-514, Revision 1, Revise BWR Operability Requirements and Actions for RCS Leakage Instrument. ML0927801932009-10-30030 October 2009 Notice of Opportunity for Comment on the Proposed Models TSTF Traveler-493, Rev. 4, Clarify Application of Setpoint Methodology for LSSS Functions. ML0925705772009-10-0101 October 2009 Notice of Opportunity for Public Comment on the Proposed Models for Plant Specific Adoption of TSTF Traveler-508, Rev. 1, Revise Control Room Habitability Actions to Address Lessons Learned from TSTF-448 Implementation. ML0924606642009-09-24024 September 2009 Notice of Opportunity for Public Comment on the Proposed Model SE of TSTF Traveler-513, Revision 2, Revise PWR Operability Requirements and Actions for RCS Leakage Instrumentation ML0922606642009-09-0202 September 2009 FRN: Notice of Opportunity for Public Comment on the Proposed Model Safety Evaluation for Plant-Specific Adoption of Technical Specification Task Force Traveler-446 Rev 3, Risk Informed Evaluation of Extensions to Containment Isolation... ML0917302362009-08-12012 August 2009 FRN for Nfc of Proposed Model Safety Evaluation for Plant-Specific Adoption of Technical Specification Task Force Traveler-501, Revision 1, Relocate Stored Fuel Oil and Lube Oil Volume Values to Licensee Control. ML0909007162009-06-23023 June 2009 Fr Notice of Availability of Technical Specification Improvement to Relocate Surveillance Frequencies to Licensee Control - Risk-Informed Technical Specification Task Force Initiative 5b, Technical Specification Task Force-425, Revision 3 ML0627601092006-10-12012 October 2006 Notice of Availability of Model Safety Evaluation on Technical Specification Improvement to Modify Requirements Regarding LCO 3.10.1, Inservice Leak and Hydrostatic Testing Operation Using the Consolidated Line Item Improvement Process 2017-10-27
[Table view] |
Text
[7590-01-P]
NUCLEAR REGULATORY COMMISSION
[Project No. 753; NRC-2016-0063]
TS Inservice Testing Program Removal & Clarify SR Usage Rule Application to Section 5.5 Testing AGENCY: Nuclear Regulatory Commission.
ACTION: Technical specifications task force; issuance.
SUMMARY
- The U.S. Nuclear Regulatory Commission (NRC) is issuing Technical Specifications (TS) Task Force (TSTF) Traveler TSTF-545, Revision 3, TS Inservice Testing
[(IST)] Program Removal & Clarify [Surveillance Requirement] SR Usage Rule Application to Section 5.5 Testing, for plant-specific adoption using the Consolidated Line Item Improvement Process (CLIIP).
DATES: March 28, 2016.
ADDRESSES: Please refer to Docket ID NRC-2016-0063 when contacting the NRC about the availability of information regarding this document. You may obtain publicly available information related to this document using any of the following methods:
- Federal Rulemaking Web Site: Go to http://www.regulations.gov and search for Docket ID NRC-2016-0063. Address questions about NRC dockets to Carol Gallagher; telephone: 301-415-3463; e-mail: Carol.Gallagher@nrc.gov. For technical questions, contact the individuals listed in the FOR FURTHER INFORMATION CONTACT section of this document.
- NRCs Agencywide Documents Access and Management System (ADAMS):
You may obtain publicly-available documents online in the ADAMS Public Documents collection at http://www.nrc.gov/reading-rm/adams.html. To begin the search, select ADAMS Public Documents and then select Begin Web-based ADAMS Search. For problems with ADAMS, please contact the NRCs Public Document Room (PDR) reference staff at 1-800-397-4209, 301-415-4737, or by e-mail to pdr.resource@nrc.gov. The ADAMS accession number for each document referenced (if it available in ADAMS) is provided the first time that a document is referenced. Traveler, TSTF-545, Revision 3, includes a model application and is available in ADAMS under Accession No. ML15294A555. The final model safety evaluation (SE) for plant-specific adoption of TSTF-545, Revision 3, is available in ADAMS under Accession No. ML15314A305.
- NRCs PDR: You may examine and purchase copies of public documents at the NRCs PDR, Room O1-F21, One White Flint North, 11555 Rockville Pike, Rockville, Maryland 20852.
FOR FURTHER INFORMATION CONTACT: Michelle C. Honcharik, telephone: 301-415-1774; e-mail: Michelle.Honcharik@nrc.gov. For technical questions please contact Caroline Tilton, telephone: 301-415-0990; e-mail: Caroline.Tilton@nrc.gov. Both are staff of the Office of Nuclear Reactor Regulation, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001.
SUPPLEMENTARY INFORMATION:
Traveler, TSTF-545, Revision 3, is applicable to all nuclear power plants. The proposed change revises the Standard TS (STS), NUREG-1430, Standard Technical Specifications Babcock and Wilcox Plants, NUREG-1431, Standard Technical Specifications Westinghouse Plants, NUREG-1432, Standard Technical Specifications Combustion Engineering Plants, NUREG-1433, Standard Technical Specifications General Electric Plants BWR/4, and NUREG-1434, Standard Technical Specifications General Electric Plants, BWR/6. This STS improvement is part of the CLIIP. NUREG-1430 through NUREG-1434, Volume 1, can be accessed in ADAMS under Accession Nos. ML12100A177, ML12100A222, ML12102A165, ML12104A192, and ML12104A195, respectively. NUREG-1430 through NUREG-1434, Volume 2, can be accessed in ADAMS under Accession Nos. ML12100A178, ML12100A228, ML12102A169, ML12104A193, and ML12104A196, respectively.
Specifically, the proposed change modifies the STS to eliminate the Chapter 5.0, Administrative Controls, specification Section 5.5, Inservice Testing Program, to remove requirements duplicated in American Society of Mechanical Engineers (ASME) Code for Operation and Maintenance of Nuclear Power Plants (OM Code), Case OMN-20, Inservice Test Frequency. The ASME Code Case, OMN-20, provides similar definitions and allowances as in the current STS Inservice Testing Program. A new defined term, Inservice Testing Program (IST), is added to STS Section 1.1, Definitions. The STS Section 3.0, Surveillance Requirement (SR) Applicability, Bases are revised to explain the application of the usage rules to the Section 5.5 testing requirements. Existing uses of the term Inservice Testing Program in the STS and STS Bases are capitalized to indicate that it is now a defined term.
The NRC staff has reviewed the model application for TSTF-545, Revision 3, and has found it acceptable for use by licensees. Licensees opting to apply for this TS change are responsible for reviewing the NRC's staff SE and the applicable technical bases, providing any necessary plant-specific information, and assessing the completeness and accuracy of their license amendment request (LAR). The NRC will process each amendment application responding to the Notice of Availability according to applicable NRC rules and procedures.
The proposed change does not prevent licensees from requesting an alternate approach or proposing changes other than those proposed in TSTF-545, Revision 3. However, significant deviations from the approach recommended in this notice or the inclusion of additional changes to the license will require additional NRC staff review. This may increase the time and resources needed for the review and/or result in NRC staff rejection of the LAR. Licensees desiring significant deviations or additional changes should instead submit an LAR that does not claim to adopt TSTF-545, Revision 3.
Dated at Rockville, Maryland, this 18th day of March 2016.
For the Nuclear Regulatory Commission,
/RA/
Kevin Hsueh, Chief, Licensing Processes Branch, Division of Policy and Rulemaking, Office of Nuclear Reactor Regulation.