September 20, 1999 Mr. W. R. McCollum, Jr.
Vice President, Oconee Site Duke Energy Corporation P.O. Box 1439 Seneca, SC 29679
SUBJECT:
OCONEE NUCLEAR STATION, UNITS 1, 2 AND 3 RE: RELIEF REQUESTS FOR THE PUMP AND VALVE INSERVICE TESTING PROGRAM (TAC NOS.
MA5898, MA5899, AND MA5900)
Dear Mr. McCollum:
By letter dated May 26, 1999, Duke Energy Corporation submitted Revision 25 of the Pump and Valve Inservice Testing Program, third 10-year interval for the Oconee Nuclear Station, Units 1, 2, and 3. The revision contained four new relief requests. As a result of a conference call held on August 24, 1999, you submitted a revision to relief request ON-SRP-LPI-06 by letter dated August 26, 1999.
On the basis of the enclosed safety evaluation, pursuant tol 0 CFR 50.55a(f)(6)(i), relief is granted for request ON-SRP-LPI-06. In making this determination, the staff has considered the impracticality of performing the required testing and the burden if the requirements were imposed.
On the basis of the enclosed safety evaluation, pursuant tol 0 CFR 50.55a(a)(3)(i), relief is granted for requests ON-GRV-12, ON-GRV-13, and ON-GRV-14. In making this determination, the staff finds that the proposed alternatives to the Code requirements for will provide an acceptable level of quality and safety.
Sincerely, Original signed by:
Richard L. Emch, Jr., Section Chief, Section 1 Project Directorate 11 Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-269, 50-270, and 50-287
Enclosure:
Safety Evaluation cc w/encl: See next page Distribution:
Docket File CHawes OGC GHiII(6)
PUBLIC DLaBarge ACRS HBerkow PDII-1 Reading RScholl (e-mail SE)
COgle, RII MSatorius, RGN II DOCUMENT NAME: G:\\PDII-1\\OCONEE\\OA5898LTR.wpd To receive a copy of this document, indicate in the box C=Copy w/o attachment/enclosure E=Copy with attachment/enclosure N= No copy OFFICE PD - /P PDII-1/LA OGC PDII-1/SC L
NAME D
a e:mw CHawes [le A ( 0 REmch DATE
/
199 1'/99
/fI 199
/12-/199
_41
-909 99092 -
OFFICIAL RE:CORD COPY 9909230003 990920 PDR ADOCK 05000269 P
1 REou4 UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 September 20, 1999 Mr. W. R. McCollum, Jr.
Vice President, Oconee Site Duke Energy Corporation P. 0. Box 1439 Seneca, SC 29679
SUBJECT:
OCONEE NUCLEAR STATION, UNITS 1, 2 AND 3 RE: RELIEF REQUESTS FOR THE PUMP AND VALVE INSERVICE TESTING PROGRAM (TAC NOS.
MA5898, MA5899, AND MA5900)
Dear Mr. McCollum:
By letter dated May 26, 1999, Duke Energy Corporation submitted Revision 25 of the Pump and Valve Inservice T esting Program, third 10-year interval for the Oconee Nuclear Station, Units 1, 2, and 3. The revision contained four new relief requests. As a result of a conference call held on August 24, 1999, you submitted a revision to relief request ON-SRP-LPI-06 by letter dated August 26, 1999.
On the basis of the enclosed safety evaluation, pursuant to10 CFR 50.55a(f)(6)(i), relief is granted for request ON-SRP-LPI-06. In making this determination, the staff has considered the impracticality of performing the required testing and the burden if the requirements were imposed.
On the basis of the enclosed safety evaluation, pursuant tol 0 CFR 50.55a(a)(3)(i), relief is granted for requests ON-GRV-12, ON-GRV-13, and ON-GRV-14. In making this determination, the staff finds that the proposed alternatives to the Code requirements for will provide an acceptable level of quality and safety.
Sincerely, Richard L. Emch, Jr., Section Chief, Section 1 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-269, 50-270, and 50-287
Enclosure:
Safety Evaluation cc w/encl: See next page
Oconee Nuclear Station cc:
Ms. Lisa F. Vaughn Mr. L. E. Nicholson Legal Department (PBO5E)
Compliance Manager Duke Energy Corporation Duke Energy Corporation 422 South Church Street Oconee Nuclear Site Charlotte, North Carolina 28201-1006 7800 Rochester Highway Seneca, South Carolina 29672 Mr. Rick N. Edwards Framatome Technologies Ms. Karen E. Long Suite 525 Assistant Attorney General 1700 Rockville Pike North Carolina Department of Rockville, Maryland 20852-1631 Justice P. O. Box 629 Manager, LIS Raleigh, North Carolina 27602 NUS Corporation 2650 McCormick Drive, 3rd Floor L. A. Keller Clearwater, Florida 34619-1035 Manager - Nuclear Regulatory Licensing Senior Resident Inspector Duke Energy Corporation U. S. Nuclear Regulatory 526 South Church Street Commission Charlotte, North Carolina 28201-1006 7812B Rochester Highway Seneca, South Carolina 29672 Mr. Richard M. Fry, Director Division of Radiation Protection Virgil R. Autry, Director North Carolina Department of Division of Radioactive Waste Management Environment, Health, and Bureau of Land and Waste Management Natural Resources Department of Health and Environmental 3825 Barrett Drive Control Raleigh, North Carolina 27609-7721 2600 Bull Street Columbia, South Carolina 29201-1708 Mr. Steven P. Shaver Senior Sales Engineer Honorable Harrison Orr Westinghouse Electric Company County Supervisor of Oconee County 5929 Carnegie Blvd.