ML15112A752

From kanterella
Jump to navigation Jump to search

Forwards SE Accepting Licensee 990806 Request for Relief to Use Alternative Rules of ASME B&PV Code on Certain Weld Matls in Replacement SGs Being Manufactured for Plant
ML15112A752
Person / Time
Site: Oconee  
Issue date: 09/10/1999
From: Emch R
NRC (Affiliation Not Assigned)
To: Mccollum W
DUKE POWER CO.
Shared Package
ML15112A753 List:
References
TAC-MA6209, TAC-MA6210, TAC-MA6211, NUDOCS 9909160162
Download: ML15112A752 (3)


Text

September 10, 1999 Mr. W. R. McCollum, Jr.

Vice President, Oconee Site Duke Energy Corporation P. 0. Box 1439 Seneca, SC 29679

SUBJECT:

OCONEE NUCLEAR STATION, UNITS 1, 2 AND 3 RE: USE OF ALTERNATIVE WELD MATERIALS IN REPLACEMENT STEAM GENERATORS (TAC NOS. MA6209, MA6210, AND MA6211)

Dear Mr. McCollum:

By letter dated August 6, 1999, Duke Energy Corporation requested relief to use the alternative rules of the American Society of Mechanical Engineers (ASME) Boiling and Pressure Vessel Code on certain weld materials in replacement steam generators that are being manufactured for the Oconee Nuclear Station, Units 1, 2, and 3. As an alternative to the Code requirements, your relief request proposed use of ASME Code Cases 2142-1 and 2143-1.

On the basis of the enclosed safety evaluation, the staff has determined that the proposed alternative would provide an acceptable level of quality and safety. Pursuant to 10 CFR 50.55a(a)(3)(i), the staff hereby authorizes the use of the proposed alternative.

Sincerely, Original signed by:

Richard L. Emch,3b, Section Chief, Section 1 Project'Directorate 11 Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-269, 50-270, and 50-287

Enclosure:

Safety Evaluation cc w/encl: See next page Distribution:

(Docket File CHawes MTschlitz F Ca op PUBLIC DLaBarge COgle, RII PDII-1 Reading RScholl (e-mail SE)

HBerkow OGC REmch ACRS Document Name: G:\\PDII-1\\OCONEE\\OA6209LTR.WPD To receive a copy of this document, indicate in the box:

"C" = Copy without attachment/enclosure "E" = Copy with attachment/enclosure "N" = No copy

  • S revious concurrence OFFICE PM P'I 1

LA:PDII/S1 OGC*

SC:PDII/S1 NAME D

ge:mw CHawes fti4 SUttal REmch DATE

/o /99..

/10 /99 9/2/99

/(0/99 OFFICIAL RECORD COPY 9909160162 990910 PDR ADOCK 05000269 P

PDR

pSREG1,'J UNITED STATE.

NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 September 10, 1999 Mr. W. R. McCollum, Jr.

Vice President, Oconee Site Duke Energy Corporation P. 0. Box 1439 Seneca, SC 29679

SUBJECT:

OCONEE NUCLEAR STATION, UNITS 1, 2 AND 3 RE: USE OF ALTEHNATIVE WELD MATERIALS IN REPLACEMENT STEAM GENERATORS (TAC NOS. MA6209, MA6210, AND MA6211)

Dear Mr. McCollum:

By letter dated August 6, 1999, Duke Energy Corporation requested relief to use the alternative rules of the American Society of Mechanical Engineers (ASME) Boiling and Pressure Vessel Code on certain weld materials in replacement steam generators that are being manufactured for the Oconee Nuclear Station, Units 1, 2, and 3. As an alternative to the Code requirements, your relief request proposed use of ASME Code Cases 2142-1 and 214 1,.

On the basis of the enclosed safety evaluation, the staff has determined that the proposed alternative would provide an acceptable level of quality and safety. Pursuant to 10 CFR 50.55a(a)(3)(i), the staff hereby authorizes the use of the proposed alternative.

Sincerely, Richard L. Emch, Jr., Section Chief, Section 1 Project Directorate II Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-269, 50-270, and 50-287

Enclosure:

Safety Evaluation cc w/encl: See next page 7/i

Oconee Nuclear Station cc:

Ms. Lisa F. Vaughn Mr. L. E. Nicholson Legal Department (PBO5E)

Compliance Manager Duke Energy Corporation Duke Energy Corporation 422 South Church Street Oconee Nuclear Site Charlotte, North Carolina 28201-1006 7800 Rochester Highway Seneca, South Carolina 29672 Mr. Rick N. Edwards Framatome Technologies Ms. Karen E. Long Suite 525 Assistant Attorney General 1700 Rockville Pike North Carolina Department of Rockville, Maryland 20852-1631 Justice P. O. Box 629 Manager, LIS Raleigh, North Carolina 27602 NUS Corporation 2650 McCormick Drive, 3rd Floor L. A. Keller Clearwater, Florida 34619-1035 Manager - Nuclear Regulatory Licensing Senior Resident Inspector Duke Energy Corporation U. S. Nuclear Regulatory 526 South Church Street Commission Charlotte, North Carolina 28201-1006 7812B Rochester Highway Seneca, South Carolina 29672 Mr. Richard M. Fry, Director Division of Radiation Protection Virgil R. Autry, Director North Carolina Department of Division of Radioactive Waste Management Environment, Health, and Bureau of Land and Waste Management Natural Resources Department of Health and Environmental 3825 Barrett Drive Control Raleigh, North Carolina 27609-7721 2600 Bull Street Columbia, South Carolina 29201-1708 Mr. Steven P. Shaver Senior Sales Engineer Honorable Harrison Orr Westinghouse Electric Company County Supervisor of Oconee County 5929 Carnegie Blvd.

Walhalla, South Carolina 29691 Suite 500 Charlotte, North Carolina 28209