124 pages follow ENCLOSURE 1 ATTACHMENT 1 SHINE MEDICAL TECHNOLOGIES, INC.

SHINE MEDICAL TECHNOLOGIES, INC. APPLICATION FOR CONSTRUCTION PERMIT RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION 11.1-9 ATKINS-NS-DAC-SHN-15-01, REVISION 0 ASSESSMENT OF DOSE TO THE PUBLIC DUE TO NORMAL GASEOUS EFFLUENT RELEASES

Design Analyses and Calculation Page 2 of 125 Form Atkins-NS-EN-13-03 R3 Rev.

Date Revision Description/Reason 0

3/20/2015 Original Issue

Design Analyses and Calculation Page 3 of 125 Form Atkins-NS-EN-13-03 R3 Table of Contents 1

INTRODUCTION............................................................................................................................. 4

1.1 BACKGROUND

/PURPOSE.................................................................................................................... 4 1.2 LIMITS OF APPLICABILITY.................................................................................................................... 4 2

CONCLUSIONS.............................................................................................................................. 4 3

ANALYSIS/PROCESS METHODOLOGY........................................................................................ 4 4

COMPUTER CODES USED IN DAC............................................................................................... 4 5

ASSUMPTIONS & OPEN ITEMS.................................................................................................... 5 5.1 ASSUMPTIONS................................................................................................................................... 5 5.2 OPEN ITEMS...................................................................................................................................... 6 6

ACCEPTANCE CRITERIA.............................................................................................................. 6 6.1 BIASES AND UNCERTAINTIES............................................................................................................... 6 6.2 AREA OF APPLICABILITY (AOA)............................................................................................................ 6 6.3 EFFLUENT RELEASE DOSE LIMITS....................................................................................................... 6 7

CALCULATIONS............................................................................................................................ 6 7.1 METHOD DISCUSSION........................................................................................................................ 6 7.1.1 SOURCE TERM.................................................................................................................................. 6 7.1.2 DISPERSION...................................................................................................................................... 7 7.1.3 DOSE CALCULATION........................................................................................................................... 7 7.2 INPUT............................................................................................................................................... 8 7.2.1 SOURCE TERM.................................................................................................................................. 8 7.2.2 DISPERSION...................................................................................................................................... 9 7.2.3 DOSE CALCULATION........................................................................................................................... 9 8

EVALUATIONS, ANALYSIS, AND DETAILED CALCULATIONS................................................. 15 9

REFERENCES.............................................................................................................................. 20 APPENDIX 1: REPRESENTATIVE INPUT FILES................................................................................. 21 APPENDIX 2: OUTPUT FILES............................................................................................................. 71

Design Analyses and Calculation Page 4 of 125 Form Atkins-NS-EN-13-03 R3 1

INTRODUCTION 1.1 Background/Purpose SHINE Medical Technologies has designed a system to generate molybdenum-99 (Mo-99) for use as a medical isotope. The SHINE facility generates gaseous effluents resulting from process operations and the ventilation of operating areas. All gaseous effluents from the production process are vented to the atmosphere through the main stack on the production facility building. As stated, in part, in 10 CFR 20.1301 (Ref. 1), operations shall be conducted so that the total effective dose equivalent (TEDE) to the individual members of the public from licensed operations does not exceed 0.1 rem (1 mSv) in a year. An additional ALARA requirement is also included in 10 CFR 20.1101 which requires TEDE due to air emissions be constrained to 0.01 rem. This calculation determines the TEDE to the maximally exposed individual (MEI) at or beyond the site boundary and the nearest resident for applicable environmental pathways for gaseous effluents due to normal operations.

1.2 Limits of Applicability The applicability of the calculations is limited to the magnitude and distribution of radionuclides provided in the source term reference and the assumptions given in Section 6.1.

2 CONCLUSIONS The annual airborne dose to the public from all pathways due to normal operations airborne effluents are below the 10 CFR 20.1301 operating TEDE limit of 0.1 rem and the ALARA requirement constraining the TEDE to 0.01 rem due to air emissions for the MEI and nearest resident. The tables in Section 8 summarize the doses to the MEI and nearest resident by age range, radionuclide, and pathway. Within five miles of the SHINE facility, there are both dairy and goat production; therefore the intake of goat milk versus cow milk was considered. The GENII2 code does not specifically allow for analysis of the grass-goat-milk-man pathway; therefore, the goat nuclide transfer parameters for iodine in milk were substituted for the cow nuclide transfer parameters and the goat consumption rates were adjusted to determine the effect of goat milk consumption on the total dose. In all cases, the potential doses due to consumption of goat milk exceeded doses due to consumption of cow milk; therefore, all dose consequences are reported for goat milk consumption.

3 ANALYSIS/PROCESS METHODOLOGY Gaseous effluents from the production process are released from the facility, dispersed into the atmosphere, deposited into the environment, and transported via air and biological activity.

The analysis methodology utilizes the quantity of material released into the effluent system (referred to as source term) based on previous source term work performed for the license application development. Utilizing this calculated source term and previously calculated dispersion factors, the GENII2 computer code calculates the quantity of material transported, deposited, inhaled, externally irradiated by, and ingested by the theoretical MEI at the site boundary and the nearest resident.

4 COMPUTER CODES USED IN DAC The GENII2 computer code was developed for the Environmental Protection Agency (EPA) at Pacific Northwest National Laboratory (PNNL) to incorporate the internal dosimetry models recommended by the International Commission on Radiological Protection (ICRP) and the radiological risk estimating procedures of Federal Guidance Report (FGR) 13 into updated versions of existing environmental pathway analysis models. The following describes the specifics of the GENII2 code to be employed:

Design Analyses and Calculation Page 5 of 125 Form Atkins-NS-EN-13-03 R3 Code:

GENII2 Version:

2.10.1 Users Manual:

GENII Version 2 Users Guide (PNNL-14583 Rev. 4) (Ref. 2)

Computer:

Dell Latitude E5520 Service Tag 6KQB6S1 NSA Tag NSA-228 Windows 7 Ultimate Service Pack 1 Product ID:

00426-OEM-8992662-0040 The GENII2 Computer Program was installed on the referenced equipment and the installation verification was performed successfully on 3/4/2014 and documented in NSA-TR-14-03, Installation and Verification of GENII2 Computer Program on NSA Computer NSA-228 (Ref.

3). The initial installation was verified by example cases illustrated in the GENII Version 2 Users Guide. Prior to execution of the code for the purposes of this calculation, the same example cases were executed with successful replication of the published results.

5 ASSUMPTIONS & OPEN ITEMS 5.1 Assumptions The following assumptions were made regarding the source term, dispersion, and dose calculations.

Source Term:

The source term utilized in the determination of dose due to gaseous effluents was based on Table 6.1-6, Summarized Gaseous Effluent Annual Average Activity Release Rates by Isotope, as documented in S&L 2012-08751 Rev. 2, Normal Gaseous Effluent Releases:

Radionuclide Concentrations and Dose Assessment (Ref. 4). The assumptions utilized in the development of this source term are described in the document.

Iodine in the atmosphere resulting from operational or incidental releases may be present as iodine bound with aerosol particles, as elemental iodine gas, and as organic gaseous iodine compounds. Prior GENII2 analysis work modeling iodine releases was performed by GENII2 author Bruce Napier in PNNL-20440, Dry Deposition Velocity Estimation for the Los Alamos Site (Ref. 5). The PNNL report summarized experimental studies which had been previously conducted in which iodine was released into the atmosphere in elemental form. These experimental studies report that releases of elemental gaseous iodine resulted in the presence of 30% of iodine in particulate form, 36% of iodine in gaseous organic form, and 34% of iodine in gaseous elemental form beyond a distance of 3 kilometers downwind. Although the MEI is located within a 3 kilometer distance, the I-131 source term released is assumed to be 30%

particulate and 70% gaseous for the purposes of this analysis.

As described in the Preliminary Safety Analysis Report (Ref. 6), decayed off-gases are released through a scrubber containing a sodium hydroxide caustic scrub solution which removes iodine from the effluent. The removal efficiency of the scrubber has not been taken into account in this analysis therefore the resulting doses reported are conservatively higher than expected due to the iodine removal capabilities of the scrubber.

Dispersion:

The gaseous effluent in the analysis is modeled as a point source release at an exit height of 10 m consistent with S&L 2012-03856, Long Term Diffusion Estimates for SHINE (Ref. 7).

The atmospheric dispersion factors (/Q) and deposition factors (D/Q) reported in S&L 2012-03856 (Ref. 7), Tables 6.1-1, 6.2-1 and 6.2-4 were entered directly into the GENII2 code.

Reference 7 assumes that the height of the vent release point is 10 m above plant grade. All

Design Analyses and Calculation Page 6 of 125 Form Atkins-NS-EN-13-03 R3 other assumptions associated with the generation of the dispersion and deposition factors are documented in Reference 7.

Dose Calculation:

All dose receptors analyzed are assumed to have continuous occupancy based on 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> per day and 365 days per year. Indoor and outdoor specific occupancy are based on GENII2 Users Guide recommendations.

5.2 Open Items There are no open items.

6 ACCEPTANCE CRITERIA 6.1 Biases and Uncertainties The code methodology benchmark bias and bias uncertainties are not used to determine a process limit or margin of safety in this analysis and are not used in this analysis.

6.2 Area of Applicability (AoA)

Not applicable 6.3 Effluent Release Dose Limits These analyses are performed to verify that operation of the facility meets the TEDE limits for individual members of the public as stated in 10 CFR 20 (Ref. 1). Specifically, the 10 CFR 20.1301 TEDE limit of 0.1 rem and the 10 CFR 20.1101 ALARA TEDE constraint due to air emissions of 10 mrem (0.01 rem) are compared for acceptance in this calculation. No specific dose limits are included for organ doses.

The analyses provide design basis dose calculations for the MEI and nearest resident, considering all age groups and all applicable pathways, examining, in particular, the closest recipients (i.e., at the site boundary) in each of the sixteen (16) meteorological sectors.

7 CALCULATIONS 7.1 Method Discussion The overall method requires the selection of the source term, the determination of the dispersion data to be utilized, and the construction and execution of the GENII2 code platform.

The output of the final dose determination is a product of the execution of the GENII2 code.

7.1.1 Source Term The source term is based on Table 6.1-6, Summarized Gaseous Effluent Annual Average Activity Release Rates by Isotope, as documented in S&L 2012-08751 Normal Gaseous Effluent Releases: Radionuclide Concentrations and Dose Assessment (Ref. 4). The source term as documented in Reference 4 assumed an iodine partition factor of 10% which is conservative with respect to data in Appendix B of WASH-1258, Numerical Guidelines for Design Objectives and Limiting Conditions for Operation to Meet the Criterion As Low as Practicable for Radioactive Material in Light Water Cooled Nuclear Power Effluents (Ref. 8).

WASH-1258 forms the underlying basis for 10 CFR 50, Domestic Licensing of Production and Utilization Facilities, Appendix I (Ref. 9) and Regulatory Guide 1.109, Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR 50, Appendix I (Ref. 10). As described in Section 5.1 the I-131

Design Analyses and Calculation Page 7 of 125 Form Atkins-NS-EN-13-03 R3 source term released is assumed to be 30% particulate and 70% gaseous for the purposes of this analysis.

7.1.2 Dispersion The GENII2 code allows for the use of pre-calculated atmospheric dispersion factors which are commonly known as (/Q) and deposition factors (D/Q). 7KH4DQG'4UHSRUWHGLQ6 /

2012-03856, Long Term Diffusion Estimates for SHINE (Ref. 7), Tables 6.1-1, 6.2-1 and 6.2-4 were therefore input directly into the GENII2 code. 7KH4DQG'4 factors for each of the 16 22.5° sectors relative to the center of the SHINE site, extending from the site boundary 50 miles outward were entered into the code. The GENII2 code then reports the MEI based on those 16 meteorological sectors.

7.1.3 Dose Calculation The GENII2 platform was constructed utilizing the following code components:

Constituent (con8) using the GENII2 Radionuclide Database Selection model allowing selection of constituents of concern.

AFF Air (usr9) using the GENII2 Air Module as the air emission rates are known based on the source term.

Air (air10) using the GENII2 Air XQ Chronic Module allowing input of estimates of potential ambient air concentration and dry and wet deposition rates.

Exposure Pathways (exp12) using the GENII2 Chronic Exposure Module to estimate concentrations in exposure media for atmospheric transport pathways. Exposure pathways include agricultural product consumption, soil contamination pathways, losses by leaching, harvest removal, and radioactive decay from the surface soil.

Receptor Intakes (rcp13) using the GENII2 Receptor Intake Module to estimate annual, time integrated intakes from exposure to contaminated soil and atmospheric transport pathways for four age groups.

Health Impacts (hei14) using the GENII2 Health Impacts Module to calculated health impacts from intake or exposure to radionuclides reported as dose using ICRP 30 dose conversion factors. The module includes consideration of farm product consumption, soil contact exposure, and air exposure.

Report Generator (nes15) using the GENII2 Air Dose Report Generator to generate output reports.

The effective dose equivalent is calculated using the following equation:

=

Equation 1

Design Analyses and Calculation Page 8 of 125 Form Atkins-NS-EN-13-03 R3 Where HE

=

effective dose equivalent wT

=

weighting factor HT

=

mean dose equivalent to organ T 7.2 Input The following technical input used was utilized in the analyses.

7.2.1 Source Term The source term is based on Table 6.1-6, Summarized Gaseous Effluent Annual Average Activity Release Rates by Isotope, as documented in S&L 2012-08751, Normal Gaseous Effluent Releases: Radionuclide Concentrations and Dose Assessment (Ref. 4).

The Ar-41 source is as stated in SHINE PSAR Section 11.1.1.1 (Ref. 6).

Table 7-1 Gaseous Effluent Source Term Radionuclide Source Term 1 (Ci/yr)

Ar-41 1.52E+01 I-131 9.498E-01 Kr-85 1.197E+02 Xe-131m 5.535E+02 Xe-133 1.076E+04 Xe-133m 4.706E-01

Design Analyses and Calculation Page 9 of 125 Form Atkins-NS-EN-13-03 R3 As discussed previously in Section 5.1, the I-131 source term was input as 70% gas and 30%

particulate to account for the potential downwind physical and chemical partition of iodine.

7.2.2 Dispersion The ground level 4DQG'4UHSRUWed in S&L 2012-03856, Long Term Diffusion Estimates for SHINE (Ref. 7), Tables 6.1-1, 6.2-1, and 6.2-4 are input directly into the GENII2 code.

7.2.3 Dose Calculation Site specific parameters, Regulatory Guide 1.109 (Ref. 10), and default GENII2 input parameters are utilized in the dose calculations. For selection of input parameters the following hierarchy was established: (1) site-specific data, (2) Regulatory Guide 1.109 (Ref.

10), and (3) GENII2 default parameters. Each of the following discussions defines the inputs required for each of the GENII2 modules and the associated reference for each input.

Constituent The following constituents were selected based on the source term:

x Ar-41 x

I-131 x

Kr-85 x

Xe-131m x

Xe-133 x

Xe-133m The properties of the constituents include a number of physical and chemical properties and a subset of the radiation dosimetry parameters such as inhalation and ingestion dose and risk conversion factors. Environmental transport parameters such as food bioaccumulation factors, soil-to-plant and feed-to-animal product transfer parameters, and various environmental rate parameters are included. This module contains a collection of the potential constituent characteristics utilized by the GENII2 code. Selected constituent parameters may not be used for this calculation such as aquatic bioaccumulation factor as the SHINE facility has no liquid effluents. With the exception of nuclide transfer parameters for cow and goats milk, the default GENII2 inputs were selected for all constituent properties. The input file is included in Appendix 1. The following table summarizes the transfer parameters for the grass-cow-milk-man pathway for I-131.

Table 7-2 Constituent Input Parameters Input Parameter Value Justification Feed to Meat Transfer Factor for I-131 2.9E-03 Regulatory Guide 1.109 Table E-1 Feed to Milk Transfer Factor for Iodine (Cow) 6.0E-03 Regulatory Guide 1.109 Table E-1 Feed to Milk Transfer Factor for Iodine (Goat) 0.06 Regulatory Guide 1.109 Table E-2 AFF Air

Design Analyses and Calculation Page 10 of 125 Form Atkins-NS-EN-13-03 R3 The following input parameters were utilized in the AFF Air module. As the 4 values are based on S&L 2012-03856 (Ref. 7), the AFF Air input values were selected for consistency.

GENII2 requires that a minimum of two time points are entered for the radionuclide release rates therefore, the annual release rate is entered at 0 years and 1 year. The I-131 release is treated as 70% gaseous and 30% particulate as described in Section 5.1. The GENII2 input file for the AFF Air module is included in Appendix 1.

Table 7-3 AFF Air Input Parameters Input Parameter Value Justification Type of Source Point The release is modeled as a ground release from a vent therefore it is assumed a point source.

Flux Types Gas; Particulate The I-131 release is assumed to have both a gas and particulate component; the remaining constituents are noble gases and therefore assumed to be only gas.

Reactive Gas Fraction for Iodine 0.5 Regulatory Guide 1.109 Appendix C (pg 1.109-26) indicates about half the radioiodine emissions may be considered non-elemental and therefore assumed non-reactive Exit Area of Source 0.1 m2 Per S&L 2012-03856 which assumes a vent diameter of 0 m2. GENII2 requires an exit area greater than 0 m2 therefore an exit area of 0.1 m2 is assumed.

Exit Height of Source 10 m Per S&L 2012-03856 Height of Adjacent Structure 10 m Assumed equivalent to the exit height of the vent.

Exit Velocity of Source 0 m/sec Per S&L 2012-03856 Exit Temperature of Source 9.3° C Assumed equivalent to ambient temperature to suppress plume rise.

Ambient Air Temperature 9.3° C Per PSAR Table 19.3.2-20 Ar-41 release rate Table 7-1 See Section 7.1.1 I-131 release rate Table 7-1 See Section 7.1.1 Kr-85 release rate Table 7-1 See Section 7.1.1 Xe-131m release rate Table 7-1 See Section 7.1.1 Xe-133 release rate Table 7-1 See Section 7.1.1

Design Analyses and Calculation Page 11 of 125 Form Atkins-NS-EN-13-03 R3 Input Parameter Value Justification Xe-133m release rate Table 7-1 See Section 7.1.1 Air S&L 2012-03856 (Ref. 7) calculation derived /Q and D/Q long term diffusion estimates for application to normal operations. The values were input directly into the GENII2 Air module.

The /Q values for each of 16 radial directions and 22 distances were input from Table 6.1-1 and 6.2-1 of S&L 2012-03856 (Ref. 7); the D/Q values for each of 16 radial directions and 22 distances were input from Table 6.1-1 and 6.2-4 of the same reference. The GENII2 input file for the Air module and the storexq.csv input file are included in Appendix 1.

Exposure Pathways As described previously, the hierarchy established for selecting input parameters was (1) site-specific data obtained from PSAR Chapter 19 (Ref. 6), (2) Regulatory Guide 1.109 guidance (Ref. 10), and (3) GENII2 default parameters. As the GENII2 default parameters establish the foundation for the GENII2 code, the following table summarizes the input parameters obtained from PSAR Chapter 19 and Regulatory Guide 1.109; all remaining input parameters were retained at the GENII2 default value. The parameters are organized by module input screen.

The GENII2 input file for the Exposure Pathways module is included in Appendix 1.

Table 7-4 Exposure Pathways Input Parameters Input Parameter Value Justification Main Control Tab Exposure Pathways Animal product ingestion Terrestrial food crop ingestion These are the pathways associated with airborne releases; the remaining pathways are associated with aquatic releases.

Duration of exposure period 1.0 yr The dose is calculated for an annual release therefore the duration of exposure is set at 1 yr End of release period 30 yrs Per PSAR Chapter 15.2, the operating license is expected to be a 30 year term Time from start to exposure 15 yrs Regulatory Guide 1.109 Table E-15 period of long-term buildup for activity in soil Average rain rate, when raining 34.79 in/yr Average rain rate from PSAR Tables 19.3.2-2 and 19.3.2-3 Soil - Surface Soil Surface soil areal density 240.0 kg/m2 Regulatory Guide 1.109 Table E-15 effective surface density of soil Surface soil layer thickness used for density 15.0 cm Regulatory Guide 1.109 Table E-15 assumes a 15 cm plow layer Surface soil density 1600.0 kg/m3 Derived from surface soil areal density and surface soil layer thickness

Design Analyses and Calculation Page 12 of 125 Form Atkins-NS-EN-13-03 R3 Input Parameter Value Justification Agriculture - General Dry deposition interception fraction to plants 1

Regulatory Guide 1.109 Table E-15 fraction of deposited activity retained on crops, leafy vegetables, or pasture grass value for iodine Weathering rate constant from plants 14.0 d Regulatory Guide 1.109 Table E-15 rate constant of 0.0021 hr-1 for removal of activity on plant or leaf surfaces by weathering (corresponds to 14-day half-life)

Agriculture - Animal Feed - Consumption Milk cow feed consumption rate (hay) - for goat analysis 1.5 kg/d Regulatory Guide 1.109 Table E-3 does not differentiate between feed and forage. The GENII2 default feed and forage consumption rates for milk cows of 14 kg/d and 41 kg/d for a total of 55 kg/d exceed the feed and forage total rate of 50 kg/d in Reg Guide 1.109 Table E-3. For cows, the GENII2 default values are retained. For goats, the 6 kg/day value from Reg Guide 1.109 Table E-3 is divided between feed and forage at a ratio consistent with the GENII2 cow default values. For goats, the feed rate is therefore (14/55)*6 kg/d=1.5 kg/d and the forage rate is therefore (41/55)*6 kg/d=4.5 kg/d.

Milk cow forage consumption rate (grass) -

for goat analysis 4.5 kg/d Agriculture - Animal Feed - Storage Time Storage time for meat animal feed 90 d Time delay between harvest of vegetation or crops and ingestion for ingestion of forage by animals for stored feed Agriculture - Animal Feed - Growing Period Growing period for milk animal feed 30 d Regulatory Guide 1.109 Table E-15 Period of crop, leafy vegetable, or pasture grass exposure during growing season

- 30 days for grass-cow-milk-man pathway Agriculture - Animal Feed - Yield Yield of milk animal feed 0.7 kg/m2 Regulatory Guide 1.109 Table E-15 agricultural productivity by unit area for grass-cow-milk-man pathway Yield of milk animal forage 0.7 kg/m2 Regulatory Guide 1.109 Table E-15 agricultural productivity by unit area for grass-cow-milk-man pathway Agriculture - Food Crop - Growing Period Growing period for leafy vegetables 60.0 d Regulatory Guide 1.109 Table E-15 period of crop, leafy vegetable, or pasture grass exposure during growing season

- 60 days for crop/vegetation-man pathway Growing period for root vegetables 60.0 d Regulatory Guide 1.109 Table E-15 period of crop, leafy vegetable, or pasture grass exposure during growing season

- 60 days for crop/vegetation-man pathway

Design Analyses and Calculation Page 13 of 125 Form Atkins-NS-EN-13-03 R3 Input Parameter Value Justification Growing period for fruits 60.0 d Regulatory Guide 1.109 Table E-15 period of crop, leafy vegetable, or pasture grass exposure during growing season

- 60 days for crop/vegetation-man pathway Growing period for grains 60.0 d Assumed same as crop/vegetation-man pathway.

Agriculture - Food Crop - Yield Yield of leafy vegetables 2.0 kg/m2 Regulatory Guide 1.109 Table E-15 agricultural productivity by unit area for produce or leafy vegetables ingested by man Yield of root vegetables 2.0 kg/m2 Regulatory Guide 1.109 Table E-15 agricultural productivity by unit area for produce or leafy vegetables ingested by man Yield of fruits 2.0 kg/m2 Regulatory Guide 1.109 Table E-15 agricultural productivity by unit area for produce or leafy vegetables ingested by man Yield of grains 2.0 kg/m2 Assumed same as produce or leafy vegetables ingested by man.

Agriculture - Intake Delays Time from harvest to ingestion of leafy vegetables 1.0 day Regulatory Guide 1.109 Table E-15 Time delay between harvest of vegetation or crops and ingestion - For ingestion of crops by man for leafy vegetables and maximum individual Time from harvest to ingestion of root vegetables 60.0 days Regulatory Guide 1.109 Table E-15 Time delay between harvest of vegetation or crops and ingestion - For ingestion of crops by man for produce and maximum individual Time from harvest to ingestion of fruits 60.0 days Regulatory Guide 1.109 Table E-15 Time delay between harvest of vegetation or crops and ingestion - For ingestion of crops by man for produce and maximum individual Time from harvest to ingestion of grains 60.0 days Assumed same as produce.

Time from harvest to ingestion of meat 20.0 days Regulatory Guide 1.109 Table E-15 average time from slaughter of meat animal to consumption Pathways Ingestion All available pathways selected N/A Inhalation All available pathways selected N/A External All available pathways selected Finite plume model not selected for conservatism

Design Analyses and Calculation Page 14 of 125 Form Atkins-NS-EN-13-03 R3 Receptor Intakes In accordance with Section B of Regulatory Guide 1.109 (Ref. 10), the exposed population is considered to be made up of four age groups: infants (0 to 1 year), children (1 to 11 years),

teenagers (11 to 17 years), and adults (17 years and older). The receptor intake input parameters are either applicable across all of the age groups or age specific. The following table summarizes the receptor intake input parameters and organized by applicability across age groups and age-group specific.

As the GENII2 default parameters establish the foundation for the GENII2 code, the following table summarizes the input parameters obtained from Regulatory Guide 1.109; all remaining input parameters were retained at the GENII2 default value.

As the effluent pathways do not include liquid releases, input parameters necessary to calculate dose due to liquid pathways have been retained at the GENII2 default values.

Table 7-5 Receptor Intakes Input Parameters Input Parameter Value Justification Input Parameters Applicable to All Age Groups External Ground Exposure Indoor shielding factor 0.7 Regulatory Guide 1.109 Table E-15 Attenuation factor accounting for shielding provided by residential structures -

0.7 for maximum individuals Input Parameters Specific to Age Group Input Parameter Value by Age Justification Infant Child Teen Adult Food Crop Ingestion Leaf vegetable consumption rate 0 kg/yr 26.0 kg/yr 42.0 kg/yr 64.0 kg/yr Regulatory Guide 1.109 Table E-5 Root vegetable consumption rate 0 kg/yr 280.8 kg/yr 340.2 kg/yr 280.8 kg/yr Regulatory Guide 1.109 Table E-5 Fruit consumption rate 0 kg/yr 114.4 kg/yr 138.6 kg/yr 114.4 kg/yr Regulatory Guide 1.109 Table E-5 Grain consumption rate 0 kg/yr 124.8 kg/yr 151.2 kg/yr 124.8 kg/yr Regulatory Guide 1.109 Table E-5 Meat consumption rate 0 kg/yr 41.0 kg/yr 65.0 kg/yr 110.0 kg/yr Regulatory Guide 1.109 Table E-5 Poultry consumption rate 0 kg/yr GENII2 default GENII2 default GENII2 default Regulatory Guide 1.109 Table E-5 for infant Milk consumption rate 0.904 kg/day 0.904 kg/day 1.10 kg/day 0.84 kg/day Regulatory Guide 1.109 Table E-5 (assumed 1 kg/l)

Egg consumption rate 0 kg/yr GENII2 default GENII2 default GENII2 default Regulatory Guide 1.109 Table E-5 for infant Air Inhalation

Design Analyses and Calculation Page 15 of 125 Form Atkins-NS-EN-13-03 R3 Input Parameter Value Justification Air inhalation rate 1400 m3/yr 3700 m3/yr 8000 m3/yr 8000 m3/yr Regulatory Guide 1.109 Table E-5 Indoor Inhalation Indoor inhalation rate 1400 m3/yr 3700 m3/yr 8000 m3/yr 8000 m3/yr Regulatory Guide 1.109 Table E-5 Health Impacts The radiation and dose and risk are calculated based on ICRP-30/48 (Federal Guidance Reports 11/12). The thickness and density of contaminated soil was assumed consistent with Table 7-2. The thyroid tissue weighting factor is 0.03 per ICRP 30, Limits for Intakes of Radionuclides by Workers (Ref. 11).

Report Generator The report generator input selection specified that only individual dose/risk results be reported along with results by pathway and radionuclide.

8 EVALUATIONS, ANALYSIS, AND DETAILED CALCULATIONS The following tables summarize the dose to the MEI and nearest resident by age group, radionuclide and pathway. The MEI considers the closest recipients in each of the 16 meteorological sectors reporting the maximum dose over all sectors and distances analyzed.

Within five miles of the SHINE facility, there are both dairy and goat production facilities; as the milk pathway is a dominant pathway, the intake of goat milk versus cow milk was considered.

The GENII2 code does not specifically allow for analysis of the grass-goat-milk-man pathway therefore, the goat nuclide transfer parameters for iodine in milk were substituted for the cow nuclide transfer parameters and the goat consumption rates were adjusted to determine the effect of goat milk consumption on the total dose. In all cases, the potential doses due to consumption of goat milk exceeded doses due to consumption of cow milk therefore, all dose consequences are reported for goat milk consumption.

The infant I-131 organ dose to the thyroid due to ingestion of milk is calculated using Equation 1 by dividing the I-131 effective dose equivalent for the milk ingestion pathway by the thyroid organ weighting factor of 0.03 to yield a mean dose equivalent to the thyroid of 0.08 rem/yr for milk ingestion.

Table 8-1 Annual Dose Summary by Age Group and Radionuclide Age Range Radionuclide MEI TEDE (rem/yr)

(all pathways)

Nearest Resident TEDE (rem/yr)

(all pathways) 0-1 yr Ar-41 2.61E-04 1.94E-05 I-131 2.42E-03 1.56E-04 Kr-85 3.74E-06 2.79E-07 Xe-131m 5.66E-05 4.22E-06 Xe-133 4.41E-03 3.29E-04 Xe-133m 1.47E-07 1.10E-08 Total 7.15E-03 5.09E-04 1-11 yr Ar-41 2.61E-04 1.94E-05 I-131 3.14E-03 2.02E-04 Kr-85 3.74E-06 2.79E-07 Xe-131m 5.66E-05 4.22E-06

Design Analyses and Calculation Page 16 of 125 Form Atkins-NS-EN-13-03 R3 Age Range Radionuclide MEI TEDE (rem/yr)

(all pathways)

Nearest Resident TEDE (rem/yr)

(all pathways)

Xe-133 4.41E-03 3.29E-04 Xe-133m 1.47E-07 1.10E-08 Total 7.87E-03 5.55E-04 11-17 yr Ar-41 2.61E-04 1.94E-05 I-131 4.28E-03 2.80E-04 Kr-85 3.74E-06 2.79E-07 Xe-131m 5.66E-05 4.22E-06 Xe-133 4.41E-03 3.29E-04 Xe-133m 1.47E-07 1.10E-08 Total 9.01E-03 6.33E-04 17-70 yr Ar-41 2.61E-04 1.94E-05 I-131 3.91E-03 2.55E-04 Kr-85 3.74E-06 2.79E-07 Xe-131m 5.66E-05 4.22E-06 Xe-133 4.41E-03 3.29E-04 Xe-133m 1.47E-07 1.10E-08 Total 8.64E-03 6.08E-04 Table 8-2 Annual Dose Summary by Age Range and Pathway Age Range Pathway MEI TEDE (individual pathways)

(rem/yr)

Nearest Resident TEDE (individual pathways)

(rem/yr) 0-1 yr Air-external 4.74E-03 3.53E-04 Air-inhalation 2.46E-05 1.84E-06 Eggs-ingestion 0.00E+00 0.00E+00 Fruit-ingestion 0.00E+00 0.00E+00 Grain-ingestion 0.00E+00 0.00E+00 Ground-external 2.12E-05 1.35E-06 Indoor air-inhalation 7.39E-05 5.51E-06 Leafy vegetables-ingestion 0.00E+00 0.00E+00 Meat-ingestion 0.00E+00 0.00E+00 Milk-ingestion 2.30E-03 1.47E-04 Poultry-ingestion 0.00E+00 0.00E+00 Root vegetables-ingestion 0.00E+00 0.00E+00 Soil-ingestion 9.94E-09 6.31E-10 Soil-inhalation 0.00E+00 0.00E+00 1-11 yr Air-external 4.74E-03 3.53E-04 Air-inhalation 6.51E-05 4.85E-06 Eggs-ingestion 1.28E-08 8.15E-10

Design Analyses and Calculation Page 17 of 125 Form Atkins-NS-EN-13-03 R3 Age Range Pathway MEI TEDE (individual pathways)

(rem/yr)

Nearest Resident TEDE (individual pathways)

(rem/yr)

Fruit-ingestion 9.22E-07 5.88E-08 Grain-ingestion 1.89E-06 1.21E-07 Ground-external 2.12E-05 1.35E-06 Indoor air-inhalation 1.96E-04 1.46E-05 Leafy vegetables-ingestion 5.08E-04 3.25E-05 Meat-ingestion 4.61E-05 2.94E-06 Milk-ingestion 2.29E-03 1.45E-04 Poultry-ingestion 2.23E-10 1.42E-11 Root vegetables-ingestion 3.40E-06 2.16E-07 Soil-ingestion 9.94E-09 6.31E-10 Soil-inhalation 0.00E+00 0.00E+00 11-17 yr Air-external 4.74E-03 3.53E-04 Air-inhalation 1.40E-04 1.05E-05 Eggs-ingestion 1.28E-08 8.15E-10 Fruit-ingestion 1.12E-06 7.11E-08 Grain-ingestion 2.29E-06 1.45E-07 Ground-external 2.12E-05 1.35E-06 Indoor air-inhalation 4.22E-04 3.15E-05 Leafy vegetables-ingestion 8.22E-04 5.26E-05 Meat-ingestion 7.32E-05 4.65E-06 Milk-ingestion 2.79E-03 1.79E-04 Poultry-ingestion 2.23E-10 1.42E-11 Root vegetables-ingestion 4.12E-06 2.62E-07 Soil-ingestion 9.94E-09 6.31E-10 Soil-inhalation 0.00E+00 0.00E+00 17-70 yr Air-external 4.74E-03 3.53E-04 Air-inhalation 1.40E-04 1.05E-05 Eggs-ingestion 1.28E-08 8.15E-10 Fruit-ingestion 9.22E-07 5.88E-08 Grain-ingestion 1.89E-06 1.21E-07 Ground-external 2.12E-05 1.35E-06 Indoor air-inhalation 4.22E-04 3.15E-05 Leafy vegetables-ingestion 1.06E-03 6.75E-05 Meat-ingestion 1.24E-04 7.88E-06 Milk-ingestion 2.13E-03 1.36E-04 Poultry-ingestion 2.23E-10 1.42E-11 Root vegetables-ingestion 3.40E-06 2.16E-07 Soil-ingestion 9.94E-09 6.31E-10 Soil-inhalation 0.00E+00 0.00E+00

Design Analyses and Calculation Page 18 of 125 Form Atkins-NS-EN-13-03 R3

Design Analyses and Calculation Page 19 of 125 Form Atkins-NS-EN-13-03 R3 Table 8-3 MEI Annual Dose Summary by Sector Sector TEDE (all pathways)

(rem/yr) 0-1 yr 1-11 yr 11-17 yr 17-70 yr N

5.0E-03 5.6E-03 6.4E-03 6.1E-03 NNE 4.3E-03 4.8E-03 5.5E-03 5.3E-03 NE 2.5E-03 2.8E-03 3.2E-03 3.1E-03 ENE 3.3E-03 3.6E-03 4.2E-03 4.0E-03 E

7.2E-03 7.9E-03 9.0E-03 8.6E-03 ESE 4.6E-03 5.1E-03 5.8E-03 5.6E-03 SE 4.1E-03 4.6E-03 5.3E-03 5.0E-03 SSE 3.2E-03 3.5E-03 4.1E-03 3.9E-03 S

3.6E-03 3.9E-03 4.5E-03 4.3E-03 SSW 2.0E-03 2.2E-03 2.5E-03 2.4E-03 SW 2.4E-03 2.6E-03 3.1E-03 2.9E-03 WSW 2.0E-03 2.2E-03 2.5E-03 2.4E-03 WSW 3.0E-03 3.3E-03 3.8E-03 3.7E-03 WNW 3.3E-03 3.6E-03 4.1E-03 4.0E-03 NW 3.0E-03 3.3E-03 3.7E-03 3.6E-03 NNW 2.9E-03 3.2E-03 3.6E-03 3.5E-03 Maximum 7.2E-03 7.9E-03 9.0E-03 8.6E-03

Design Analyses and Calculation Page 20 of 125 Form Atkins-NS-EN-13-03 R3 9

REFERENCES 1.

U.S. Nuclear Regulatory Commission, Standards for Protection Against Radiation, 10 CFR 20, Source 56 FR 23398, May 21, 1991.

2.

Pacific Northwest National Laboratory, GENII Version 2 Users Guide, PNNL-14583, Rev.

4, September 2012.

3.

Nuclear Safety Associates, Installation and Verification of GENII2 Computer Program on NSA Computer NSA-228, NSA-TR-14-03, Rev. 0, March 2014.

4.

Sargent and Lundy, Normal Gaseous Effluent Releases: Radionuclide Concentrations and Dose Assessment, S&L 2012-08751, Rev. 2, May 2013.

5.

PNNL-20440, Dry Deposition Velocity Estimation at the Los Alamos Site, Rev 0, May 2011.

6.

SHINE Medical Technologies, Inc., Preliminary Safety Analysis Report, Effective Date 2/6/15 7.

Sargent and Lundy, Long-Term Diffusion Estimates for SHINE, S&L 2012-03856, Rev. 0, August 2012.

8.

USAEC, Numerical Guidelines for Design Objectives and Limiting Conditions for Operation to Meet the Criterion As Low as Practicable for Radioactive Material in Light Water Cooled Nuclear Power Effluents, WASH-1258, July 1973.

9.

U.S. Nuclear Regulatory Commission, Domestic Licensing of Production and Utilization Facilities 10 CFR 50, Source 79 FR 62344, October 2014

10. U.S. Nuclear Regulatory Commission, Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10 CFR 50, Appendix I, Regulatory Guide 1.109, Rev. 1, October 1977.
11. International Council on Radiological Protection, Limits for Intakes of Radionuclides by Workers, ICRP-30, 1979.

Design Analyses and Calculation Page 21 of 125 Form Atkins-NS-EN-13-03 R3 APPENDIX 1: REPRESENTATIVE INPUT FILES

Design Analyses and Calculation Page 22 of 125 Form Atkins-NS-EN-13-03 R3 CONSTITUENT MODULE INPUT

  • File: c:\\frames\\shine\\nrgoat30.gid
  • Section: con8
  • Date: 3/18/2015 5:55:59 PM CDBE Version for Site 1 (Version): 1.7 Number of Constituents for Site 1 (NumCon): 6 The Chemical Abstracts Service Identification number for Site 1 for FSCASID 1 (FSCASID): AR41 Constituent Name for Site 1 for AR41 (FSCNAME): AR41 Number of straight chain decay products for Site 1 for AR41 (NDS): 0 The Chemical Abstracts Service Identification number for Site 1 for FSCASID 1 (FSCASID): I131 Constituent Name for Site 1 for I131 (FSCNAME): I131 Number of straight chain decay products for Site 1 for I131 (NDS): 1 The Chemical Abstracts Service Identification number for Site 1 for FSCASID 1 (FSCASID): XE131m Constituent Name for Site 1 for XE131m (FSCNAME): XE131m First dregration product fraction for Site 1 for XE131m (FSFRACTION): 0.011 fraction The Chemical Abstracts Service Identification number for Site 1 for FSCASID 1 (FSCASID): KR85 Constituent Name for Site 1 for KR85 (FSCNAME): KR85 Number of straight chain decay products for Site 1 for KR85 (NDS): 0 The Chemical Abstracts Service Identification number for Site 1 for FSCASID 1 (FSCASID): XE131m Constituent Name for Site 1 for XE131m (FSCNAME): XE131m Number of straight chain decay products for Site 1 for XE131m (NDS): 0 The Chemical Abstracts Service Identification number for Site 1 for FSCASID 1 (FSCASID): XE133 Constituent Name for Site 1 for XE133 (FSCNAME): XE133 Number of straight chain decay products for Site 1 for XE133 (NDS): 0 The Chemical Abstracts Service Identification number for Site 1 for FSCASID 1 (FSCASID): XE133m Constituent Name for Site 1 for XE133m (FSCNAME): XE133m Number of straight chain decay products for Site 1 for XE133m (NDS): 1 The Chemical Abstracts Service Identification number for Site 1 for FSCASID 1 (FSCASID): XE133 Constituent Name for Site 1 for XE133 (FSCNAME): XE133 First dregration product fraction for Site 1 for XE133 (FSFRACTION): 1 fraction Inhalation Volatilization Factor for Indoors for Site 1 for AR41 (CLANDF): 1 m^3/L Reference for CLANDF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Fish from Freshwater for Site 1 for AR41 (CLBFF): 0 L/kg Reference for CLBFF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Crustacea from Freshwater for Site 1 for AR41 (CLBFI): 0 L/kg Reference for CLBFI Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Mollusk from Freshwater for Site 1 for AR41 (CLBFM): 0 L/kg Reference for CLBFM Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Plants from Freshwater for Site 1 for AR41 (CLBFP): 0 L/kg Reference for CLBFP Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Fish from Saltwater for Site 1 for AR41 (CLBMF): 0 L/kg Reference for CLBMF Reference ID #1

Design Analyses and Calculation Page 23 of 125 Form Atkins-NS-EN-13-03 R3

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Crustacea from Saltwater for Site 1 for AR41 (CLBMI): 0 L/kg Reference for CLBMI Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Mollusk from Saltwater for Site 1 for AR41 (CLBMM): 0 L/kg Reference for CLBMM Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Plants from Saltwater for Site 1 for AR41 (CLBMP): 0 L/kg Reference for CLBMP Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Animal Forage from Soil for Site 1 for AR41 (CLBVAF): 0 kg/kg Reference for CLBVAF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Animal Grain from Soil for Site 1 for AR41 (CLBVAG): 0 kg/kg Reference for CLBVAG Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Animal Hay from Soil for Site 1 for AR41 (CLBVAH): 0 kg/kg Reference for CLBVAH Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Cereal from Soil for Site 1 for AR41 (CLBVCL): 0 kg/kg Reference for CLBVCL Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in Dry Fruit from Soil for Site 1 for AR41 (CLBVFR): 0 kg/kg Reference for CLBVFR Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Leafy Vegetables from Soil for Site 1 for AR41 (CLBVLV): 0 kg/kg Reference for CLBVLV Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in Dry Other Vegetables from Soil for Site 1 for AR41 (CLBVOV): 0 kg/kg Reference for CLBVOV Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Root Vegetables from Soil for Site 1 for AR41 (CLBVRV): 0 kg/kg Reference for CLBVRV Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Constituent classification type for Site 1 for AR41 (CLCHEM): 0 External Dose Factor, Air Immersion for Site 1 for AR41 (CLDEX): 0.0000000008658 rem/hr per pCi/m^3 Reference for CLDEX Reference ID #1

Design Analyses and Calculation Page 24 of 125 Form Atkins-NS-EN-13-03 R3

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Dose Factor, class Day for Site 1 for AR41 (CLDFAD): 0 rem/pCi Reference for CLDFAD Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Dose Factor, class Week for Site 1 for AR41 (CLDFAW): 0 rem/pCi Reference for CLDFAW Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Dose Factor, class Year for Site 1 for AR41 (CLDFAY): 0 rem/pCi Reference for CLDFAY Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Water Immersion for Site 1 for AR41 (CLDIMR): 0.00000000187812 rem/hr per pCi/L Reference for CLDIMR Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Ground Surface for Site 1 for AR41 (CLDSH): 0.000000000015984 rem/hr per pCi/m^2 Reference for CLDSH Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Ground Contaminated to 15cm for Site 1 for AR41 (CLDSH15): 4.95504E-13 rem/hr per pCi/m^3 Reference for CLDSH15 Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Ground Contaminated to 5cm for Site 1 for AR41 (CLDSH5): 1.03763E-13 rem/hr per pCi/m^3 Reference for CLDSH5 Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Constituent exposure type for Site 1 for AR41 (CLETYPE): 1 Feed to Egg Transfer Factor for Site 1 for AR41 (CLFEG): 0 day/kg Reference for CLFEG Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Feed to Milk Transfer Factor for Site 1 for AR41 (CLFMK): 0 day/L Reference for CLFMK Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Feed to Meat Transfer Factor for Site 1 for AR41 (CLFMT): 0 day/kg Reference for CLFMT Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Feed to Poultry Transfer Factor for Site 1 for AR41 (CLFPL): 0 day/kg Reference for CLFPL Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The dry soil-water partition coefficient for Site 1 for AR41 (CLKD): 0 mL/g Reference for CLKD Reference ID #1

Design Analyses and Calculation Page 25 of 125 Form Atkins-NS-EN-13-03 R3

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Radionclide flag for Site 1 for AR41 (CLKTYPE): 1 Periodic Table type for Site 1 for AR41 (CLPTYPE): 1 Ingestion Dose Factor, insoluble for Site 1 for AR41 (CLRDFGI): 0 rem/pCi Reference for CLRDFGI Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Ingestion Dose Factor, soluble for Site 1 for AR41 (CLRDFGS): 0 rem/pCi Reference for CLRDFGS Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

RAAS classification type for Site 1 for AR41 (CLRTYPE): 14 External Slope Factor for Site 1 for AR41 (CLSFEX): 7.63631E-11 risk/yr per pCi/m^2 Reference for CLSFEX Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Ingestion Slope Factor, Water for Site 1 for AR41 (CLSFG): 0 risk/pCi Reference for CLSFG Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Slope Factor for Site 1 for AR41 (CLSFH): 0 risk/pCi Reference for CLSFH Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The decay half-life in Soil for Site 1 for AR41 (CLSHALF): 316.463 day Reference for CLSHALF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The atmospheric deposition velocity for Site 1 for AR41 (CLVD): 0 m/s Reference for CLVD Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The water purification factor for Site 1 for AR41 (CLWPF): 0 fraction Reference for CLWPF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The lung solubility class ICRP72 for Site 1 for AR41 (SOLUBIL): G Reference for SOLUBIL Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Volatilization Factor for Indoors for Site 1 for I131 (CLANDF): 0 m^3/L Reference for CLANDF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Fish from Freshwater for Site 1 for I131 (CLBFF): 40 L/kg Reference for CLBFF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Crustacea from Freshwater for Site 1 for I131 (CLBFI): 100 L/kg

Design Analyses and Calculation Page 26 of 125 Form Atkins-NS-EN-13-03 R3 Reference for CLBFI Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Mollusk from Freshwater for Site 1 for I131 (CLBFM): 100 L/kg Reference for CLBFM Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Plants from Freshwater for Site 1 for I131 (CLBFP): 300 L/kg Reference for CLBFP Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Fish from Saltwater for Site 1 for I131 (CLBMF): 10 L/kg Reference for CLBMF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Crustacea from Saltwater for Site 1 for I131 (CLBMI): 50 L/kg Reference for CLBMI Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Mollusk from Saltwater for Site 1 for I131 (CLBMM): 50 L/kg Reference for CLBMM Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Plants from Saltwater for Site 1 for I131 (CLBMP): 1500 L/kg Reference for CLBMP Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Animal Forage from Soil for Site 1 for I131 (CLBVAF): 0.04 kg/kg Reference for CLBVAF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Animal Grain from Soil for Site 1 for I131 (CLBVAG): 0.04 kg/kg Reference for CLBVAG Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Animal Hay from Soil for Site 1 for I131 (CLBVAH): 0.04 kg/kg Reference for CLBVAH Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Cereal from Soil for Site 1 for I131 (CLBVCL): 0.04 kg/kg Reference for CLBVCL Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in Dry Fruit from Soil for Site 1 for I131 (CLBVFR): 0.04 kg/kg Reference for CLBVFR Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Leafy Vegetables from Soil for Site 1 for I131 (CLBVLV): 0.04 kg/kg Reference for CLBVLV

Design Analyses and Calculation Page 27 of 125 Form Atkins-NS-EN-13-03 R3 Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in Dry Other Vegetables from Soil for Site 1 for I131 (CLBVOV): 0.04 kg/kg Reference for CLBVOV Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Root Vegetables from Soil for Site 1 for I131 (CLBVRV): 0.04 kg/kg Reference for CLBVRV Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Constituent classification type for Site 1 for I131 (CLCHEM): 0 External Dose Factor, Air Immersion for Site 1 for I131 (CLDEX): 0.000000000242424 rem/hr per pCi/m^3 Reference for CLDEX Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Dose Factor, class Day for Site 1 for I131 (CLDFAD): 0.000000032893 rem/pCi Reference for CLDFAD Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Dose Factor, class Week for Site 1 for I131 (CLDFAW): 0 rem/pCi Reference for CLDFAW Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Dose Factor, class Year for Site 1 for I131 (CLDFAY): 0 rem/pCi Reference for CLDFAY Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Dose Factor Particle Diameter for Site 1 for I131 (CLDIAM): 1 um Reference for CLDIAM Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Water Immersion for Site 1 for I131 (CLDIMR): 0.000000000530136 rem/hr per pCi/L Reference for CLDIMR Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Ground Surface for Site 1 for I131 (CLDSH): 5.00832E-12 rem/hr per pCi/m^2 Reference for CLDSH Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Ground Contaminated to 15cm for Site 1 for I131 (CLDSH15): 1.42524E-13 rem/hr per pCi/m^3 Reference for CLDSH15 Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Ground Contaminated to 5cm for Site 1 for I131 (CLDSH5): 3.23676E-14 rem/hr per pCi/m^3 Reference for CLDSH5 Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Constituent exposure type for Site 1 for I131 (CLETYPE): 1 Feed to Egg Transfer Factor for Site 1 for I131 (CLFEG): 4.4 day/kg

Design Analyses and Calculation Page 28 of 125 Form Atkins-NS-EN-13-03 R3 Reference for CLFEG Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Feed to Milk Transfer Factor for Site 1 for I131 (CLFMK): 0.06 day/L Feed to Meat Transfer Factor for Site 1 for I131 (CLFMT): 0.0029 day/kg Reference for CLFMT Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Feed to Poultry Transfer Factor for Site 1 for I131 (CLFPL): 0.05 day/kg Reference for CLFPL Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The dry soil-water partition coefficient for Site 1 for I131 (CLKD): 15 mL/g Reference for CLKD Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Radionclide flag for Site 1 for I131 (CLKTYPE): 1 Periodic Table type for Site 1 for I131 (CLPTYPE): 2 Ingestion Dose Factor, insoluble for Site 1 for I131 (CLRDFGI): 0.00000005328 rem/pCi Reference for CLRDFGI Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Ingestion Dose Factor, soluble for Site 1 for I131 (CLRDFGS): 0 rem/pCi Reference for CLRDFGS Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

RAAS classification type for Site 1 for I131 (CLRTYPE): 14 External Slope Factor for Site 1 for I131 (CLSFEX): 2.31191E-11 risk/yr per pCi/m^2 Reference for CLSFEX Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Ingestion Slope Factor, Water for Site 1 for I131 (CLSFG): 0.000000000006845 risk/pCi Reference for CLSFG Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Slope Factor for Site 1 for I131 (CLSFH): 0.000000000005476 risk/pCi Reference for CLSFH Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The decay half-life in Soil for Site 1 for I131 (CLSHALF): 14557.3 day Reference for CLSHALF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The atmospheric deposition velocity for Site 1 for I131 (CLVD): 0.01 m/s Reference for CLVD Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The water purification factor for Site 1 for I131 (CLWPF): 1 fraction Reference for CLWPF Reference ID #1

Design Analyses and Calculation Page 29 of 125 Form Atkins-NS-EN-13-03 R3

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The dose factor for Freshwater Algae for Site 1 for I131 (FALGDF): 0.0000001968 rad/day per Bq/kg Reference for FALGDF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The dose factor for Freshwater Crustacea for Site 1 for I131 (FCRUDF): 0.0000002064 rad/day per Bq/kg Reference for FCRUDF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The dose factor for Freshwater Fish for Site 1 for I131 (FFISDF): 0.000000336 rad/day per Bq/kg Reference for FFISDF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The dose factor for Freshwater Mollusc for Site 1 for I131 (FMOLDF): 0.000000288 rad/day per Bq/kg Reference for FMOLDF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The dose factor for Marine Algae for Site 1 for I131 (MALGDF): 0.000000288 rad/day per Bq/kg Reference for MALGDF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The dose factor for Marine Crustacea for Site 1 for I131 (MCRUDF): 0.0000004216 rad/day per Bq/kg Reference for MCRUDF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The dose factor for Marine Fish for Site 1 for I131 (MFISDF): 0.000000312 rad/day per Bq/kg Reference for MFISDF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The dose factor for Marine Mollusc for Site 1 for I131 (MMOLDF): 0.000000288 rad/day per Bq/kg Reference for MMOLDF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The dose factor for Riparian Bird for Site 1 for I131 (RBIRDF): 0.000000336 rad/day per Bq/kg Reference for RBIRDF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The dose factor for Riparian Mammal for Site 1 for I131 (RMAMDF): 0.000000312 rad/day per Bq/kg Reference for RMAMDF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The lung solubility class ICRP72 for Site 1 for I131 (SOLUBIL): F Reference for SOLUBIL Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The dose factor for Terrestrial Bird for Site 1 for I131 (TBIRDF): 0.0000004688 rad/day per Bq/kg Reference for TBIRDF Reference ID #1

Reference:

Napier 2002

Design Analyses and Calculation Page 30 of 125 Form Atkins-NS-EN-13-03 R3 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The dose factor for Terrestrial Egg for Site 1 for I131 (TEGGDF): 0.000000288 rad/day per Bq/kg Reference for TEGGDF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The dose factor for Terrestrial Mammal for Site 1 for I131 (TMAMDF): 0.0000006 rad/day per Bq/kg Reference for TMAMDF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The dose factor for Terrestrial Plant for Site 1 for I131 (TPLADF): 0.000000264 rad/day per Bq/kg Reference for TPLADF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Volatilization Factor for Indoors for Site 1 for XE131m (CLANDF): 1 m^3/L Reference for CLANDF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Fish from Freshwater for Site 1 for XE131m (CLBFF): 0 L/kg Reference for CLBFF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Crustacea from Freshwater for Site 1 for XE131m (CLBFI): 0 L/kg Reference for CLBFI Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Mollusk from Freshwater for Site 1 for XE131m (CLBFM): 0 L/kg Reference for CLBFM Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Plants from Freshwater for Site 1 for XE131m (CLBFP): 0 L/kg Reference for CLBFP Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Fish from Saltwater for Site 1 for XE131m (CLBMF): 0 L/kg Reference for CLBMF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Crustacea from Saltwater for Site 1 for XE131m (CLBMI): 0 L/kg Reference for CLBMI Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Mollusk from Saltwater for Site 1 for XE131m (CLBMM): 0 L/kg Reference for CLBMM Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Plants from Saltwater for Site 1 for XE131m (CLBMP): 0 L/kg Reference for CLBMP Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Design Analyses and Calculation Page 31 of 125 Form Atkins-NS-EN-13-03 R3 Bioconcentration in dry Animal Forage from Soil for Site 1 for XE131m (CLBVAF): 0 kg/kg Reference for CLBVAF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Animal Grain from Soil for Site 1 for XE131m (CLBVAG): 0 kg/kg Reference for CLBVAG Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Animal Hay from Soil for Site 1 for XE131m (CLBVAH): 0 kg/kg Reference for CLBVAH Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Cereal from Soil for Site 1 for XE131m (CLBVCL): 0 kg/kg Reference for CLBVCL Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in Dry Fruit from Soil for Site 1 for XE131m (CLBVFR): 0 kg/kg Reference for CLBVFR Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Leafy Vegetables from Soil for Site 1 for XE131m (CLBVLV): 0 kg/kg Reference for CLBVLV Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in Dry Other Vegetables from Soil for Site 1 for XE131m (CLBVOV): 0 kg/kg Reference for CLBVOV Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Root Vegetables from Soil for Site 1 for XE131m (CLBVRV): 0 kg/kg Reference for CLBVRV Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Constituent classification type for Site 1 for XE131m (CLCHEM): 0 External Dose Factor, Air Immersion for Site 1 for XE131m (CLDEX): 5.18148E-12 rem/hr per pCi/m^3 Reference for CLDEX Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Dose Factor, class Day for Site 1 for XE131m (CLDFAD): 0 rem/pCi Reference for CLDFAD Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Dose Factor, class Week for Site 1 for XE131m (CLDFAW): 0 rem/pCi Reference for CLDFAW Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Dose Factor, class Year for Site 1 for XE131m (CLDFAY): 0 rem/pCi Reference for CLDFAY Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Design Analyses and Calculation Page 32 of 125 Form Atkins-NS-EN-13-03 R3 External Dose Factor, Water Immersion for Site 1 for XE131m (CLDIMR): 1.18948E-11 rem/hr per pCi/L Reference for CLDIMR Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Ground Surface for Site 1 for XE131m (CLDSH): 2.74392E-13 rem/hr per pCi/m^2 Reference for CLDSH Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Ground Contaminated to 15cm for Site 1 for XE131m (CLDSH15): 1.58508E-15 rem/hr per pCi/m^3 Reference for CLDSH15 Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Ground Contaminated to 5cm for Site 1 for XE131m (CLDSH5): 7.64568E-16 rem/hr per pCi/m^3 Reference for CLDSH5 Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Constituent exposure type for Site 1 for XE131m (CLETYPE): 1 Feed to Egg Transfer Factor for Site 1 for XE131m (CLFEG): 0 day/kg Reference for CLFEG Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Feed to Milk Transfer Factor for Site 1 for XE131m (CLFMK): 0 day/L Reference for CLFMK Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Feed to Meat Transfer Factor for Site 1 for XE131m (CLFMT): 0 day/kg Reference for CLFMT Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Feed to Poultry Transfer Factor for Site 1 for XE131m (CLFPL): 0 day/kg Reference for CLFPL Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The dry soil-water partition coefficient for Site 1 for XE131m (CLKD): 0 mL/g Reference for CLKD Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Radionclide flag for Site 1 for XE131m (CLKTYPE): 1 Periodic Table type for Site 1 for XE131m (CLPTYPE): 1 Ingestion Dose Factor, insoluble for Site 1 for XE131m (CLRDFGI): 0 rem/pCi Reference for CLRDFGI Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Ingestion Dose Factor, soluble for Site 1 for XE131m (CLRDFGS): 0 rem/pCi Reference for CLRDFGS Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

RAAS classification type for Site 1 for XE131m (CLRTYPE): 14 External Slope Factor for Site 1 for XE131m (CLSFEX): 8.0333E-13 risk/yr per pCi/m^2 Reference for CLSFEX

Design Analyses and Calculation Page 33 of 125 Form Atkins-NS-EN-13-03 R3 Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Ingestion Slope Factor, Water for Site 1 for XE131m (CLSFG): 0 risk/pCi Reference for CLSFG Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Slope Factor for Site 1 for XE131m (CLSFH): 0 risk/pCi Reference for CLSFH Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The decay half-life in Soil for Site 1 for XE131m (CLSHALF): 316.463 day Reference for CLSHALF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The atmospheric deposition velocity for Site 1 for XE131m (CLVD): 0 m/s Reference for CLVD Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The water purification factor for Site 1 for XE131m (CLWPF): 0 fraction Reference for CLWPF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The lung solubility class ICRP72 for Site 1 for XE131m (SOLUBIL): G Reference for SOLUBIL Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Volatilization Factor for Indoors for Site 1 for KR85 (CLANDF): 1 m^3/L Reference for CLANDF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Fish from Freshwater for Site 1 for KR85 (CLBFF): 0 L/kg Reference for CLBFF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Crustacea from Freshwater for Site 1 for KR85 (CLBFI): 0 L/kg Reference for CLBFI Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Mollusk from Freshwater for Site 1 for KR85 (CLBFM): 0 L/kg Reference for CLBFM Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Plants from Freshwater for Site 1 for KR85 (CLBFP): 0 L/kg Reference for CLBFP Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Fish from Saltwater for Site 1 for KR85 (CLBMF): 0 L/kg Reference for CLBMF Reference ID #1

Design Analyses and Calculation Page 34 of 125 Form Atkins-NS-EN-13-03 R3

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Crustacea from Saltwater for Site 1 for KR85 (CLBMI): 0 L/kg Reference for CLBMI Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Mollusk from Saltwater for Site 1 for KR85 (CLBMM): 0 L/kg Reference for CLBMM Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Plants from Saltwater for Site 1 for KR85 (CLBMP): 0 L/kg Reference for CLBMP Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Animal Forage from Soil for Site 1 for KR85 (CLBVAF): 0 kg/kg Reference for CLBVAF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Animal Grain from Soil for Site 1 for KR85 (CLBVAG): 0 kg/kg Reference for CLBVAG Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Animal Hay from Soil for Site 1 for KR85 (CLBVAH): 0 kg/kg Reference for CLBVAH Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Cereal from Soil for Site 1 for KR85 (CLBVCL): 0 kg/kg Reference for CLBVCL Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in Dry Fruit from Soil for Site 1 for KR85 (CLBVFR): 0 kg/kg Reference for CLBVFR Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Leafy Vegetables from Soil for Site 1 for KR85 (CLBVLV): 0 kg/kg Reference for CLBVLV Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in Dry Other Vegetables from Soil for Site 1 for KR85 (CLBVOV): 0 kg/kg Reference for CLBVOV Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Root Vegetables from Soil for Site 1 for KR85 (CLBVRV): 0 kg/kg Reference for CLBVRV Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Constituent classification type for Site 1 for KR85 (CLCHEM): 0 External Dose Factor, Air Immersion for Site 1 for KR85 (CLDEX): 1.58508E-12 rem/hr per pCi/m^3 Reference for CLDEX Reference ID #1

Design Analyses and Calculation Page 35 of 125 Form Atkins-NS-EN-13-03 R3

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Dose Factor, class Day for Site 1 for KR85 (CLDFAD): 0 rem/pCi Reference for CLDFAD Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Dose Factor, class Week for Site 1 for KR85 (CLDFAW): 0 rem/pCi Reference for CLDFAW Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Dose Factor, class Year for Site 1 for KR85 (CLDFAY): 0 rem/pCi Reference for CLDFAY Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Water Immersion for Site 1 for KR85 (CLDIMR): 3.3966E-12 rem/hr per pCi/L Reference for CLDIMR Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Ground Surface for Site 1 for KR85 (CLDSH): 3.51648E-14 rem/hr per pCi/m^2 Reference for CLDSH Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Ground Contaminated to 15cm for Site 1 for KR85 (CLDSH15): 9.28404E-16 rem/hr per pCi/m^3 Reference for CLDSH15 Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Ground Contaminated to 5cm for Site 1 for KR85 (CLDSH5): 2.17116E-16 rem/hr per pCi/m^3 Reference for CLDSH5 Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Constituent exposure type for Site 1 for KR85 (CLETYPE): 1 Feed to Egg Transfer Factor for Site 1 for KR85 (CLFEG): 0 day/kg Reference for CLFEG Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Feed to Milk Transfer Factor for Site 1 for KR85 (CLFMK): 0 day/L Reference for CLFMK Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Feed to Meat Transfer Factor for Site 1 for KR85 (CLFMT): 0 day/kg Reference for CLFMT Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Feed to Poultry Transfer Factor for Site 1 for KR85 (CLFPL): 0 day/kg Reference for CLFPL Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The dry soil-water partition coefficient for Site 1 for KR85 (CLKD): 0 mL/g Reference for CLKD Reference ID #1

Design Analyses and Calculation Page 36 of 125 Form Atkins-NS-EN-13-03 R3

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Radionclide flag for Site 1 for KR85 (CLKTYPE): 1 Periodic Table type for Site 1 for KR85 (CLPTYPE): 1 Ingestion Dose Factor, insoluble for Site 1 for KR85 (CLRDFGI): 0 rem/pCi Reference for CLRDFGI Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Ingestion Dose Factor, soluble for Site 1 for KR85 (CLRDFGS): 0 rem/pCi Reference for CLRDFGS Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

RAAS classification type for Site 1 for KR85 (CLRTYPE): 14 External Slope Factor for Site 1 for KR85 (CLSFEX): 2.51041E-13 risk/yr per pCi/m^2 Reference for CLSFEX Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Ingestion Slope Factor, Water for Site 1 for KR85 (CLSFG): 0 risk/pCi Reference for CLSFG Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Slope Factor for Site 1 for KR85 (CLSFH): 0 risk/pCi Reference for CLSFH Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The decay half-life in Soil for Site 1 for KR85 (CLSHALF): 316.463 day Reference for CLSHALF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The atmospheric deposition velocity for Site 1 for KR85 (CLVD): 0 m/s Reference for CLVD Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The water purification factor for Site 1 for KR85 (CLWPF): 0 fraction Reference for CLWPF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The lung solubility class ICRP72 for Site 1 for KR85 (SOLUBIL): G Reference for SOLUBIL Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Volatilization Factor for Indoors for Site 1 for XE131m (CLANDF): 1 m^3/L Reference for CLANDF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Fish from Freshwater for Site 1 for XE131m (CLBFF): 0 L/kg Reference for CLBFF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Crustacea from Freshwater for Site 1 for XE131m (CLBFI): 0 L/kg

Design Analyses and Calculation Page 37 of 125 Form Atkins-NS-EN-13-03 R3 Reference for CLBFI Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Mollusk from Freshwater for Site 1 for XE131m (CLBFM): 0 L/kg Reference for CLBFM Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Plants from Freshwater for Site 1 for XE131m (CLBFP): 0 L/kg Reference for CLBFP Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Fish from Saltwater for Site 1 for XE131m (CLBMF): 0 L/kg Reference for CLBMF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Crustacea from Saltwater for Site 1 for XE131m (CLBMI): 0 L/kg Reference for CLBMI Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Mollusk from Saltwater for Site 1 for XE131m (CLBMM): 0 L/kg Reference for CLBMM Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Plants from Saltwater for Site 1 for XE131m (CLBMP): 0 L/kg Reference for CLBMP Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Animal Forage from Soil for Site 1 for XE131m (CLBVAF): 0 kg/kg Reference for CLBVAF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Animal Grain from Soil for Site 1 for XE131m (CLBVAG): 0 kg/kg Reference for CLBVAG Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Animal Hay from Soil for Site 1 for XE131m (CLBVAH): 0 kg/kg Reference for CLBVAH Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Cereal from Soil for Site 1 for XE131m (CLBVCL): 0 kg/kg Reference for CLBVCL Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in Dry Fruit from Soil for Site 1 for XE131m (CLBVFR): 0 kg/kg Reference for CLBVFR Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Leafy Vegetables from Soil for Site 1 for XE131m (CLBVLV): 0 kg/kg Reference for CLBVLV

Design Analyses and Calculation Page 38 of 125 Form Atkins-NS-EN-13-03 R3 Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in Dry Other Vegetables from Soil for Site 1 for XE131m (CLBVOV): 0 kg/kg Reference for CLBVOV Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Root Vegetables from Soil for Site 1 for XE131m (CLBVRV): 0 kg/kg Reference for CLBVRV Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Constituent classification type for Site 1 for XE131m (CLCHEM): 0 External Dose Factor, Air Immersion for Site 1 for XE131m (CLDEX): 5.18148E-12 rem/hr per pCi/m^3 Reference for CLDEX Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Dose Factor, class Day for Site 1 for XE131m (CLDFAD): 0 rem/pCi Reference for CLDFAD Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Dose Factor, class Week for Site 1 for XE131m (CLDFAW): 0 rem/pCi Reference for CLDFAW Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Dose Factor, class Year for Site 1 for XE131m (CLDFAY): 0 rem/pCi Reference for CLDFAY Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Water Immersion for Site 1 for XE131m (CLDIMR): 1.18948E-11 rem/hr per pCi/L Reference for CLDIMR Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Ground Surface for Site 1 for XE131m (CLDSH): 2.74392E-13 rem/hr per pCi/m^2 Reference for CLDSH Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Ground Contaminated to 15cm for Site 1 for XE131m (CLDSH15): 1.58508E-15 rem/hr per pCi/m^3 Reference for CLDSH15 Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Ground Contaminated to 5cm for Site 1 for XE131m (CLDSH5): 7.64568E-16 rem/hr per pCi/m^3 Reference for CLDSH5 Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Constituent exposure type for Site 1 for XE131m (CLETYPE): 1 Feed to Egg Transfer Factor for Site 1 for XE131m (CLFEG): 0 day/kg Reference for CLFEG Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Feed to Milk Transfer Factor for Site 1 for XE131m (CLFMK): 0 day/L

Design Analyses and Calculation Page 39 of 125 Form Atkins-NS-EN-13-03 R3 Reference for CLFMK Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Feed to Meat Transfer Factor for Site 1 for XE131m (CLFMT): 0 day/kg Reference for CLFMT Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Feed to Poultry Transfer Factor for Site 1 for XE131m (CLFPL): 0 day/kg Reference for CLFPL Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The dry soil-water partition coefficient for Site 1 for XE131m (CLKD): 0 mL/g Reference for CLKD Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Radionclide flag for Site 1 for XE131m (CLKTYPE): 1 Periodic Table type for Site 1 for XE131m (CLPTYPE): 1 Ingestion Dose Factor, insoluble for Site 1 for XE131m (CLRDFGI): 0 rem/pCi Reference for CLRDFGI Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Ingestion Dose Factor, soluble for Site 1 for XE131m (CLRDFGS): 0 rem/pCi Reference for CLRDFGS Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

RAAS classification type for Site 1 for XE131m (CLRTYPE): 14 External Slope Factor for Site 1 for XE131m (CLSFEX): 8.0333E-13 risk/yr per pCi/m^2 Reference for CLSFEX Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Ingestion Slope Factor, Water for Site 1 for XE131m (CLSFG): 0 risk/pCi Reference for CLSFG Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Slope Factor for Site 1 for XE131m (CLSFH): 0 risk/pCi Reference for CLSFH Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The decay half-life in Soil for Site 1 for XE131m (CLSHALF): 316.463 day Reference for CLSHALF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The atmospheric deposition velocity for Site 1 for XE131m (CLVD): 0 m/s Reference for CLVD Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The water purification factor for Site 1 for XE131m (CLWPF): 0 fraction Reference for CLWPF Reference ID #1

Reference:

Napier 2002

Design Analyses and Calculation Page 40 of 125 Form Atkins-NS-EN-13-03 R3 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The lung solubility class ICRP72 for Site 1 for XE131m (SOLUBIL): G Reference for SOLUBIL Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Volatilization Factor for Indoors for Site 1 for XE133 (CLANDF): 1 m^3/L Reference for CLANDF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Fish from Freshwater for Site 1 for XE133 (CLBFF): 0 L/kg Reference for CLBFF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Crustacea from Freshwater for Site 1 for XE133 (CLBFI): 0 L/kg Reference for CLBFI Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Mollusk from Freshwater for Site 1 for XE133 (CLBFM): 0 L/kg Reference for CLBFM Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Plants from Freshwater for Site 1 for XE133 (CLBFP): 0 L/kg Reference for CLBFP Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Fish from Saltwater for Site 1 for XE133 (CLBMF): 0 L/kg Reference for CLBMF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Crustacea from Saltwater for Site 1 for XE133 (CLBMI): 0 L/kg Reference for CLBMI Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Mollusk from Saltwater for Site 1 for XE133 (CLBMM): 0 L/kg Reference for CLBMM Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Plants from Saltwater for Site 1 for XE133 (CLBMP): 0 L/kg Reference for CLBMP Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Animal Forage from Soil for Site 1 for XE133 (CLBVAF): 0 kg/kg Reference for CLBVAF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Animal Grain from Soil for Site 1 for XE133 (CLBVAG): 0 kg/kg Reference for CLBVAG Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Design Analyses and Calculation Page 41 of 125 Form Atkins-NS-EN-13-03 R3 Bioconcentration in dry Animal Hay from Soil for Site 1 for XE133 (CLBVAH): 0 kg/kg Reference for CLBVAH Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Cereal from Soil for Site 1 for XE133 (CLBVCL): 0 kg/kg Reference for CLBVCL Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in Dry Fruit from Soil for Site 1 for XE133 (CLBVFR): 0 kg/kg Reference for CLBVFR Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Leafy Vegetables from Soil for Site 1 for XE133 (CLBVLV): 0 kg/kg Reference for CLBVLV Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in Dry Other Vegetables from Soil for Site 1 for XE133 (CLBVOV): 0 kg/kg Reference for CLBVOV Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Root Vegetables from Soil for Site 1 for XE133 (CLBVRV): 0 kg/kg Reference for CLBVRV Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Constituent classification type for Site 1 for XE133 (CLCHEM): 0 External Dose Factor, Air Immersion for Site 1 for XE133 (CLDEX): 2.07792E-11 rem/hr per pCi/m^3 Reference for CLDEX Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Dose Factor, class Day for Site 1 for XE133 (CLDFAD): 0 rem/pCi Reference for CLDFAD Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Dose Factor, class Week for Site 1 for XE133 (CLDFAW): 0 rem/pCi Reference for CLDFAW Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Dose Factor, class Year for Site 1 for XE133 (CLDFAY): 0 rem/pCi Reference for CLDFAY Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Water Immersion for Site 1 for XE133 (CLDIMR): 4.71528E-11 rem/hr per pCi/L Reference for CLDIMR Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Ground Surface for Site 1 for XE133 (CLDSH): 6.14052E-13 rem/hr per pCi/m^2 Reference for CLDSH Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Design Analyses and Calculation Page 42 of 125 Form Atkins-NS-EN-13-03 R3 External Dose Factor, Ground Contaminated to 15cm for Site 1 for XE133 (CLDSH15): 7.15284E-15 rem/hr per pCi/m^3 Reference for CLDSH15 Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Ground Contaminated to 5cm for Site 1 for XE133 (CLDSH5): 2.8638E-15 rem/hr per pCi/m^3 Reference for CLDSH5 Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Constituent exposure type for Site 1 for XE133 (CLETYPE): 1 Feed to Egg Transfer Factor for Site 1 for XE133 (CLFEG): 0 day/kg Reference for CLFEG Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Feed to Milk Transfer Factor for Site 1 for XE133 (CLFMK): 0 day/L Reference for CLFMK Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Feed to Meat Transfer Factor for Site 1 for XE133 (CLFMT): 0 day/kg Reference for CLFMT Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Feed to Poultry Transfer Factor for Site 1 for XE133 (CLFPL): 0 day/kg Reference for CLFPL Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The dry soil-water partition coefficient for Site 1 for XE133 (CLKD): 0 mL/g Reference for CLKD Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Radionclide flag for Site 1 for XE133 (CLKTYPE): 1 Periodic Table type for Site 1 for XE133 (CLPTYPE): 1 Ingestion Dose Factor, insoluble for Site 1 for XE133 (CLRDFGI): 0 rem/pCi Reference for CLRDFGI Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Ingestion Dose Factor, soluble for Site 1 for XE133 (CLRDFGS): 0 rem/pCi Reference for CLRDFGS Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

RAAS classification type for Site 1 for XE133 (CLRTYPE): 14 External Slope Factor for Site 1 for XE133 (CLSFEX): 2.28856E-12 risk/yr per pCi/m^2 Reference for CLSFEX Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Ingestion Slope Factor, Water for Site 1 for XE133 (CLSFG): 0 risk/pCi Reference for CLSFG Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Slope Factor for Site 1 for XE133 (CLSFH): 0 risk/pCi Reference for CLSFH

Design Analyses and Calculation Page 43 of 125 Form Atkins-NS-EN-13-03 R3 Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The decay half-life in Soil for Site 1 for XE133 (CLSHALF): 316.463 day Reference for CLSHALF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The atmospheric deposition velocity for Site 1 for XE133 (CLVD): 0 m/s Reference for CLVD Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The water purification factor for Site 1 for XE133 (CLWPF): 0 fraction Reference for CLWPF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The lung solubility class ICRP72 for Site 1 for XE133 (SOLUBIL): G Reference for SOLUBIL Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Volatilization Factor for Indoors for Site 1 for XE133m (CLANDF): 1 m^3/L Reference for CLANDF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Fish from Freshwater for Site 1 for XE133m (CLBFF): 0 L/kg Reference for CLBFF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Crustacea from Freshwater for Site 1 for XE133m (CLBFI): 0 L/kg Reference for CLBFI Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Mollusk from Freshwater for Site 1 for XE133m (CLBFM): 0 L/kg Reference for CLBFM Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Plants from Freshwater for Site 1 for XE133m (CLBFP): 0 L/kg Reference for CLBFP Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Fish from Saltwater for Site 1 for XE133m (CLBMF): 0 L/kg Reference for CLBMF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Crustacea from Saltwater for Site 1 for XE133m (CLBMI): 0 L/kg Reference for CLBMI Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Mollusk from Saltwater for Site 1 for XE133m (CLBMM): 0 L/kg Reference for CLBMM Reference ID #1

Design Analyses and Calculation Page 44 of 125 Form Atkins-NS-EN-13-03 R3

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Plants from Saltwater for Site 1 for XE133m (CLBMP): 0 L/kg Reference for CLBMP Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Animal Forage from Soil for Site 1 for XE133m (CLBVAF): 0 kg/kg Reference for CLBVAF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Animal Grain from Soil for Site 1 for XE133m (CLBVAG): 0 kg/kg Reference for CLBVAG Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Animal Hay from Soil for Site 1 for XE133m (CLBVAH): 0 kg/kg Reference for CLBVAH Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Cereal from Soil for Site 1 for XE133m (CLBVCL): 0 kg/kg Reference for CLBVCL Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in Dry Fruit from Soil for Site 1 for XE133m (CLBVFR): 0 kg/kg Reference for CLBVFR Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Leafy Vegetables from Soil for Site 1 for XE133m (CLBVLV): 0 kg/kg Reference for CLBVLV Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in Dry Other Vegetables from Soil for Site 1 for XE133m (CLBVOV): 0 kg/kg Reference for CLBVOV Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Root Vegetables from Soil for Site 1 for XE133m (CLBVRV): 0 kg/kg Reference for CLBVRV Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Constituent classification type for Site 1 for XE133m (CLCHEM): 0 External Dose Factor, Air Immersion for Site 1 for XE133m (CLDEX): 1.82484E-11 rem/hr per pCi/m^3 Reference for CLDEX Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Dose Factor, class Day for Site 1 for XE133m (CLDFAD): 0 rem/pCi Reference for CLDFAD Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Dose Factor, class Week for Site 1 for XE133m (CLDFAW): 0 rem/pCi Reference for CLDFAW Reference ID #1

Design Analyses and Calculation Page 45 of 125 Form Atkins-NS-EN-13-03 R3

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Dose Factor, class Year for Site 1 for XE133m (CLDFAY): 0 rem/pCi Reference for CLDFAY Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Water Immersion for Site 1 for XE133m (CLDIMR): 4.04928E-11 rem/hr per pCi/L Reference for CLDIMR Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Ground Surface for Site 1 for XE133m (CLDSH): 5.42124E-13 rem/hr per pCi/m^2 Reference for CLDSH Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Ground Contaminated to 15cm for Site 1 for XE133m (CLDSH15): 8.89776E-15 rem/hr per pCi/m^3 Reference for CLDSH15 Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Ground Contaminated to 5cm for Site 1 for XE133m (CLDSH5): 2.49084E-15 rem/hr per pCi/m^3 Reference for CLDSH5 Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Constituent exposure type for Site 1 for XE133m (CLETYPE): 1 Feed to Egg Transfer Factor for Site 1 for XE133m (CLFEG): 0 day/kg Reference for CLFEG Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Feed to Milk Transfer Factor for Site 1 for XE133m (CLFMK): 0 day/L Reference for CLFMK Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Feed to Meat Transfer Factor for Site 1 for XE133m (CLFMT): 0 day/kg Reference for CLFMT Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Feed to Poultry Transfer Factor for Site 1 for XE133m (CLFPL): 0 day/kg Reference for CLFPL Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The dry soil-water partition coefficient for Site 1 for XE133m (CLKD): 0 mL/g Reference for CLKD Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Radionclide flag for Site 1 for XE133m (CLKTYPE): 1 Periodic Table type for Site 1 for XE133m (CLPTYPE): 1 Ingestion Dose Factor, insoluble for Site 1 for XE133m (CLRDFGI): 0 rem/pCi Reference for CLRDFGI Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Ingestion Dose Factor, soluble for Site 1 for XE133m (CLRDFGS): 0 rem/pCi

Design Analyses and Calculation Page 46 of 125 Form Atkins-NS-EN-13-03 R3 Reference for CLRDFGS Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

RAAS classification type for Site 1 for XE133m (CLRTYPE): 14 External Slope Factor for Site 1 for XE133m (CLSFEX): 2.03168E-12 risk/yr per pCi/m^2 Reference for CLSFEX Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Ingestion Slope Factor, Water for Site 1 for XE133m (CLSFG): 0 risk/pCi Reference for CLSFG Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Slope Factor for Site 1 for XE133m (CLSFH): 0 risk/pCi Reference for CLSFH Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The decay half-life in Soil for Site 1 for XE133m (CLSHALF): 316.463 day Reference for CLSHALF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The atmospheric deposition velocity for Site 1 for XE133m (CLVD): 0 m/s Reference for CLVD Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The water purification factor for Site 1 for XE133m (CLWPF): 0 fraction Reference for CLWPF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The lung solubility class ICRP72 for Site 1 for XE133m (SOLUBIL): G Reference for SOLUBIL Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Volatilization Factor for Indoors for Site 1 for XE133 (CLANDF): 1 m^3/L Reference for CLANDF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Fish from Freshwater for Site 1 for XE133 (CLBFF): 0 L/kg Reference for CLBFF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Crustacea from Freshwater for Site 1 for XE133 (CLBFI): 0 L/kg Reference for CLBFI Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Mollusk from Freshwater for Site 1 for XE133 (CLBFM): 0 L/kg Reference for CLBFM Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Plants from Freshwater for Site 1 for XE133 (CLBFP): 0 L/kg

Design Analyses and Calculation Page 47 of 125 Form Atkins-NS-EN-13-03 R3 Reference for CLBFP Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Fish from Saltwater for Site 1 for XE133 (CLBMF): 0 L/kg Reference for CLBMF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Crustacea from Saltwater for Site 1 for XE133 (CLBMI): 0 L/kg Reference for CLBMI Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Mollusk from Saltwater for Site 1 for XE133 (CLBMM): 0 L/kg Reference for CLBMM Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioaccumulation in Wet Plants from Saltwater for Site 1 for XE133 (CLBMP): 0 L/kg Reference for CLBMP Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Animal Forage from Soil for Site 1 for XE133 (CLBVAF): 0 kg/kg Reference for CLBVAF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Animal Grain from Soil for Site 1 for XE133 (CLBVAG): 0 kg/kg Reference for CLBVAG Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Animal Hay from Soil for Site 1 for XE133 (CLBVAH): 0 kg/kg Reference for CLBVAH Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Cereal from Soil for Site 1 for XE133 (CLBVCL): 0 kg/kg Reference for CLBVCL Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in Dry Fruit from Soil for Site 1 for XE133 (CLBVFR): 0 kg/kg Reference for CLBVFR Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Leafy Vegetables from Soil for Site 1 for XE133 (CLBVLV): 0 kg/kg Reference for CLBVLV Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in Dry Other Vegetables from Soil for Site 1 for XE133 (CLBVOV): 0 kg/kg Reference for CLBVOV Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Bioconcentration in dry Root Vegetables from Soil for Site 1 for XE133 (CLBVRV): 0 kg/kg Reference for CLBVRV

Design Analyses and Calculation Page 48 of 125 Form Atkins-NS-EN-13-03 R3 Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Constituent classification type for Site 1 for XE133 (CLCHEM): 0 External Dose Factor, Air Immersion for Site 1 for XE133 (CLDEX): 2.07792E-11 rem/hr per pCi/m^3 Reference for CLDEX Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Dose Factor, class Day for Site 1 for XE133 (CLDFAD): 0 rem/pCi Reference for CLDFAD Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Dose Factor, class Week for Site 1 for XE133 (CLDFAW): 0 rem/pCi Reference for CLDFAW Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Dose Factor, class Year for Site 1 for XE133 (CLDFAY): 0 rem/pCi Reference for CLDFAY Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Water Immersion for Site 1 for XE133 (CLDIMR): 4.71528E-11 rem/hr per pCi/L Reference for CLDIMR Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Ground Surface for Site 1 for XE133 (CLDSH): 6.14052E-13 rem/hr per pCi/m^2 Reference for CLDSH Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Ground Contaminated to 15cm for Site 1 for XE133 (CLDSH15): 7.15284E-15 rem/hr per pCi/m^3 Reference for CLDSH15 Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

External Dose Factor, Ground Contaminated to 5cm for Site 1 for XE133 (CLDSH5): 2.8638E-15 rem/hr per pCi/m^3 Reference for CLDSH5 Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Constituent exposure type for Site 1 for XE133 (CLETYPE): 1 Feed to Egg Transfer Factor for Site 1 for XE133 (CLFEG): 0 day/kg Reference for CLFEG Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Feed to Milk Transfer Factor for Site 1 for XE133 (CLFMK): 0 day/L Reference for CLFMK Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Feed to Meat Transfer Factor for Site 1 for XE133 (CLFMT): 0 day/kg Reference for CLFMT Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Feed to Poultry Transfer Factor for Site 1 for XE133 (CLFPL): 0 day/kg

Design Analyses and Calculation Page 49 of 125 Form Atkins-NS-EN-13-03 R3 Reference for CLFPL Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The dry soil-water partition coefficient for Site 1 for XE133 (CLKD): 0 mL/g Reference for CLKD Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Radionclide flag for Site 1 for XE133 (CLKTYPE): 1 Periodic Table type for Site 1 for XE133 (CLPTYPE): 1 Ingestion Dose Factor, insoluble for Site 1 for XE133 (CLRDFGI): 0 rem/pCi Reference for CLRDFGI Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Ingestion Dose Factor, soluble for Site 1 for XE133 (CLRDFGS): 0 rem/pCi Reference for CLRDFGS Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

RAAS classification type for Site 1 for XE133 (CLRTYPE): 14 External Slope Factor for Site 1 for XE133 (CLSFEX): 2.28856E-12 risk/yr per pCi/m^2 Reference for CLSFEX Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Ingestion Slope Factor, Water for Site 1 for XE133 (CLSFG): 0 risk/pCi Reference for CLSFG Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Inhalation Slope Factor for Site 1 for XE133 (CLSFH): 0 risk/pCi Reference for CLSFH Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The decay half-life in Soil for Site 1 for XE133 (CLSHALF): 316.463 day Reference for CLSHALF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The atmospheric deposition velocity for Site 1 for XE133 (CLVD): 0 m/s Reference for CLVD Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The water purification factor for Site 1 for XE133 (CLWPF): 0 fraction Reference for CLWPF Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

The lung solubility class ICRP72 for Site 1 for XE133 (SOLUBIL): G Reference for SOLUBIL Reference ID #1

Reference:

Napier 2002 Reference

Description:

BA Napier et al. 2002. GENII Version 2 Software Design Document.

Design Analyses and Calculation Page 50 of 125 Form Atkins-NS-EN-13-03 R3 AFF AIR MODULE INPUT

  • File: c:\\frames\\shine\\nrgoat30.gid
  • Section: usr9
  • Date: 3/18/2015 5:58:43 PM CVT format (CVTFormat): General Number Use progeny (progeny): False Concentration/Flux use flag (useMult): False Concentration/Flux multiplier (irMult): 1 Concentration/Flux group muiltiplier for Periodic table type, for index subtract 1 from -> 1 (irGrpMult): 1 Concentration/Flux group muiltiplier for Periodic table type, for index subtract 1 from -> 2 (irGrpMult): 1 Concentration/Flux group muiltiplier for Periodic table type, for index subtract 1 from -> 3 (irGrpMult): 1 Concentration/Flux group muiltiplier for Periodic table type, for index subtract 1 from -> 4 (irGrpMult): 1 Concentration/Flux group muiltiplier for Periodic table type, for index subtract 1 from -> 5 (irGrpMult): 1 Concentration/Flux group muiltiplier for Periodic table type, for index subtract 1 from -> 6 (irGrpMult): 1 Concentration/Flux group muiltiplier for Periodic table type, for index subtract 1 from -> 7 (irGrpMult): 1 Concentration/Flux group muiltiplier for Periodic table type, for index subtract 1 from -> 8 (irGrpMult): 1 Concentration/Flux group muiltiplier for Periodic table type, for index subtract 1 from -> 9 (irGrpMult): 1 Concentration/Flux group muiltiplier for Periodic table type, for index subtract 1 from -> 10 (irGrpMult): 1 Concentration/Flux group muiltiplier for Periodic table type, for index subtract 1 from -> 11 (irGrpMult): 1 Concentration/Flux group muiltiplier for Periodic table type, for index subtract 1 from -> 12 (irGrpMult): 1 Type of release for media 1 (media): Point Dataset and file extension (dataset): aff:Air Exit area of source for Point (one): 0.1 m^2 Reference for one Reference ID #2

Reference:

S&L 2012-03856 assumed 0 Reference

Description:

GENII requires exit area of source >0 m^2; S&L assumed 0 m^2. GENII exit area assumed to be 10 cm^2 (0.1 m^2).

Exit height of source for Point (two): 10 m Reference for two Reference ID #3

Reference:

S&L 2012-03856 assumed exit height of 10 m.

Reference

Description:

Exit height assumed consistent with S&L 2012-03856 Height of adjacent structure for Point (three): 10 m Reference for three Reference ID #4

Reference:

Assumed equivalent to exit height of source Reference

Description:

Exit velocity for Point (four): 0 m/sec Reference for four Reference ID #5

Reference:

Assumed 0 m/s consistent with S&L 2012-03856 Reference

Description:

Exit temperature of source for Point (five): 9.3 C Reference for five Reference ID #6

Reference:

Set equal to ambient temperature for non-heated release Reference

Description:

Ambient air temperature for Point (six): 9.3 C Reference for six Reference ID #7

Reference:

Assume average of average temperatures reported in PSAR Table 19.3.2-20 Reference

Description:

Use suspended particle/gas for Flux index # 0 (fluxtypes): True Use suspended particle/gas for Flux index # 1 (fluxtypes): True Use suspended particle/gas for Flux index # 2 (fluxtypes): False

Design Analyses and Calculation Page 51 of 125 Form Atkins-NS-EN-13-03 R3 Use suspended particle/gas for Flux index # 3 (fluxtypes): False Reactive gas density for Gas 1 (reactivedensity): 0.01 g/cm^3 Reactive gas fraction for Gas 1 (reactivefrac): 0.5 fraction Reference for reactivefrac Reference ID #13

Reference:

RG 1.109 Eq C-6: half the radioiodine emissions considered nonelemental.

Reference

Description:

Density for Particle 1 (density): 1.5 g/cm^3 Radius for Particle 1 (radius): 3 um Chemical Abstract System Identification for Point for AR41 (CASID): AR41 yr Time for Point for AR41 for ctime 1 (ctime): 0 yr Constituent flux for Point for AR41 for 0 for flux type # 1 (cval): 15.2 Ci/yr Constituent flux for Point for AR41 for 0 for flux type # 2 (cval): 0 pCi/yr Time for Point for AR41 for ctime 2 (ctime): 1 yr Constituent flux for Point for AR41 for 1 for flux type # 1 (cval): 15.2 Ci/yr Constituent flux for Point for AR41 for 1 for flux type # 2 (cval): 0 pCi/yr Chemical Abstract System Identification for Point for I131 (CASID): I131 yr Time for Point for I131 for ctime 1 (ctime): 0 yr Constituent flux for Point for I131 for 0 for flux type # 1 (cval): 0.66486 Ci/yr Constituent flux for Point for I131 for 0 for flux type # 2 (cval): 0.28494 Ci/yr Time for Point for I131 for ctime 2 (ctime): 1 yr Constituent flux for Point for I131 for 1 for flux type # 1 (cval): 0.66486 Ci/yr Constituent flux for Point for I131 for 1 for flux type # 2 (cval): 0.28494 Ci/yr Chemical Abstract System Identification for Point for KR85 (CASID): KR85 yr Time for Point for KR85 for ctime 1 (ctime): 0 yr Constituent flux for Point for KR85 for 0 for flux type # 1 (cval): 119.7 Ci/yr Constituent flux for Point for KR85 for 0 for flux type # 2 (cval): 0 Ci/yr Time for Point for KR85 for ctime 2 (ctime): 1 yr Constituent flux for Point for KR85 for 1 for flux type # 1 (cval): 119.7 Ci/yr Constituent flux for Point for KR85 for 1 for flux type # 2 (cval): 0 Ci/yr Chemical Abstract System Identification for Point for XE131m (CASID): XE131m yr Time for Point for XE131m for ctime 1 (ctime): 0 yr Constituent flux for Point for XE131m for 0 for flux type # 1 (cval): 553.5 Ci/yr Constituent flux for Point for XE131m for 0 for flux type # 2 (cval): 0 Ci/yr Time for Point for XE131m for ctime 2 (ctime): 1 yr Constituent flux for Point for XE131m for 1 for flux type # 1 (cval): 553.5 Ci/yr Constituent flux for Point for XE131m for 1 for flux type # 2 (cval): 0 Ci/yr Chemical Abstract System Identification for Point for XE133 (CASID): XE133 yr Time for Point for XE133 for ctime 1 (ctime): 0 yr Constituent flux for Point for XE133 for 0 for flux type # 1 (cval): 10760 Ci/yr Constituent flux for Point for XE133 for 0 for flux type # 2 (cval): 0 Ci/yr Time for Point for XE133 for ctime 2 (ctime): 1 yr Constituent flux for Point for XE133 for 1 for flux type # 1 (cval): 10760 Ci/yr Constituent flux for Point for XE133 for 1 for flux type # 2 (cval): 0 Ci/yr Chemical Abstract System Identification for Point for XE133m (CASID): XE133m yr Time for Point for XE133m for ctime 1 (ctime): 0 yr Constituent flux for Point for XE133m for 0 for flux type # 1 (cval): 0.4076 Ci/yr Constituent flux for Point for XE133m for 0 for flux type # 2 (cval): 0 Ci/yr Time for Point for XE133m for ctime 2 (ctime): 1 yr Constituent flux for Point for XE133m for 1 for flux type # 1 (cval): 0.4076 Ci/yr Constituent flux for Point for XE133m for 1 for flux type # 2 (cval): 0 Ci/yr

Design Analyses and Calculation Page 52 of 125 Form Atkins-NS-EN-13-03 R3 AIR MODULE INPUT - MEI

  • File: c:\\frames\\shine\\sbgoat30.gid
  • Section: air10
  • Date: 3/18/2015 5:05:19 PM CVT format (CVTFormat): General Number Number of distances (distances): 23 m Number of directions (directions): 16 deg XQ file name and path (filename): C:\\FRAMES\\SHINE\\storexq.csv

Design Analyses and Calculation Page 54 of 126 Form Atkins-NS-EN-13-03 R3

Design Analyses and Calculation Page 54 of 125 Form Atkins-NS-EN-13-03 R3 AIR MODULE INPUT - NEAREST RESIDENT

  • File: c:\\frames\\shine\\nrgoat30.gid
  • Section: air10
  • Date: 3/18/2015 5:59:19 PM CVT format (CVTFormat): General Number Number of distances (distances): 1 m Number of directions (directions): 1 deg XQ file name and path (filename): C:\\FRAMES\\SHINE\\nrxq.csv nrqx.csv file:

X/Q products 3 chronic Distances and units 1 m Distances 788 Directions and units 1 deg Directions 0

Concentration (GAS) s/m^3 0.0000053 Concentration s/m^3 0.0000053 Dry Deposition 1/m^2 8.9E-09

Design Analyses and Calculation Page 55 of 125 Form Atkins-NS-EN-13-03 R3 EXPOSURE PATHWAYS MODULE INPUT

  • File: c:\\frames\\shine\\nrgoat30.gid
  • Section: exp12
  • Date: 3/18/2015 6:06:06 PM Type of resuspension model (IRES): 0 Source of animal feed irrigation for meat animal feed (IRRSA): 0 Source of animal feed irrigation for poultry animal feed (IRRSA): 0 Source of animal feed irrigation for milk animal feed (IRRSA): 0 Source of animal feed irrigation for egg animal feed (IRRSA): 0 Source of animal feed irrigation for meat animal forage (IRRSA): 0 Source of animal feed irrigation for milk animal forage (IRRSA): 0 Source of irrigation for leafy vegetables (IRRST): 0 Source of irrigation for root vegetables (IRRST): 0 Source of irrigation for fruits (IRRST): 0 Source of irrigation for grains (IRRST): 0 Source of residential irrigation (IRRSR): 0 Type of leach rate constant (LEACHOPTION): 1 Source of domestic water (DWSRC): 0 Air (INHAL): True Animal product ingestion (ANFOOD): True Terrestrial food crop ingestion (TFOOD): True Aquatic food ingestion (AQFOOD): False Recreational surface water (RECRE): False Debug testing (DEBUG): False Treatment plant purification of domestic water (DWTRET): True Residential irrigation (RESIRR): True Finite plume model (FINITE): False External air (AIREXT): True Ingestion pathway for meat animal (ANF): True Ingestion pathway for poultry animal (ANF): True Ingestion pathway for milk animal (ANF): True Ingestion pathway for egg animal (ANF): True Ingestion pathway for leafy vegetables (TFD): True Ingestion pathway for root vegetables (TFD): True Ingestion pathway for fruits (TFD): True Ingestion pathway for grains (TFD): True Ingestion pathway for fish (AQF): False Ingestion pathway for mollusca (AQF): False Ingestion pathway for crustacea (AQF): False Ingestion pathway for aquatic plants (AQF): False Drinking water (DRINK): False Inadvertent shower water (SHING): False Inadvertent swimming water (SWING): False Inadvertent soil (SLING): True Indoor or showering (SHINDR): True Suspended or resuspended soil (SLINH): True External pathway for fish (REC): False External pathway for mollusca (REC): False External pathway for crustacea (REC): False Soil external (GROUND): True Aquatic foods from salt water (versus fresh water) (ISALT): True User defined dry deposition interception fraction to plants (DRYSET): True User defined wet deposition interception fraction to plants (WETSET): False Radionuclide removal due to harvesting (HARVST): True Loss of institutional control time prior to exposure (LOIC): 0 mn Irrigation water deposition time prior to exposure (BEFIRR): 0 yr Air deposition time prior to exposure (BEFAIR): 0 yr Duration of exposure period (NTKEND): 1 yr

Design Analyses and Calculation Page 56 of 125 Form Atkins-NS-EN-13-03 R3 Reference for NTKEND Reference ID #8

Reference:

Reg Guide 1.109 stipulates 1 year duration Reference

Description:

End of release period (RELEND): 30 yr Reference for RELEND Reference ID #12

Reference:

Duration of release period set at lifetime of operating license per PSAR Reference

Description:

Time from start to exposure (BEFORE): 15 yr Reference for BEFORE Reference ID #11

Reference:

Reg Guide 1.109 stipulates 15 year accumulation Reference

Description:

Absolute humidity, used only for tritium model (ABSHUM): 0.008 kg/m^3 Fraction of plants roots in surface soil (RF1): 1 fraction Mass loading factor for resuspension model (XMLF): 0.01 g/m^3 Depth of top soil available for resuspension (AVALSL): 1 cm Yield for animal feed for meat animal feed (YELDA): 0.8 kg/m^2 Yield for animal feed for poultry animal feed (YELDA): 0.8 kg/m^2 Yield for animal feed for milk animal feed (YELDA): 0.7 kg/m^2 Reference for YELDA Reference ID #20

Reference:

Reg Guide 1.109 Table E-15 Agricultural Productivity Reference

Description:

0.7 kg/m^2 for grass-cow-milk-man pathway; 2.0 kg/m^2 for produce or leafy vegetables ingested by man Yield for animal feed for egg animal feed (YELDA): 0.8 kg/m^2 Yield for animal feed for meat animal forage (YELDA): 2 kg/m^2 Yield for animal feed for milk animal forage (YELDA): 0.7 kg/m^2 Reference for YELDA Reference ID #20

Reference:

Reg Guide 1.109 Table E-15 Agricultural Productivity Reference

Description:

0.7 kg/m^2 for grass-cow-milk-man pathway; 2.0 kg/m^2 for produce or leafy vegetables ingested by man Time from harvest to animal ingestion for meat animal (HLDUPA): 20 day Reference for HLDUPA Reference ID #22

Reference:

Reg Guide 1.109 Table E-15 Ave time from slaughter of meat animal to consumption Reference

Description:

Time from harvest to animal ingestion for poultry animal (HLDUPA): 1 day Time from harvest to animal ingestion for milk animal (HLDUPA): 1 day Time from harvest to animal ingestion for egg animal (HLDUPA): 1 day Animal feed growing period for meat animal feed (GRWPA): 90 day Animal feed growing period for poultry animal feed (GRWPA): 90 day Animal feed growing period for milk animal feed (GRWPA): 30 day Reference for GRWPA Reference ID #19

Reference:

Reg Guide 1.109 Table E-15 Period of Growing Season Reference

Description:

30 days grass-cow-milk pathway; 60 days crops/vegetation-man pathway Animal feed growing period for egg animal feed (GRWPA): 90 day Animal feed growing period for meat animal forage (GRWPA): 45 day Animal feed growing period for milk animal forage (GRWPA): 30 day Storage time for meat animal feed (STORTM): 90 day Reference for STORTM Reference ID #17

Reference:

Reg Guide 1.109 Table E-15 Time Delay between harvest and ingestion Reference

Description:

For ingestion by meat animal and milk animal: 90 days for stored feed and 0 for forage.

Storage time for poultry animal feed (STORTM): 180 day Storage time for milk animal feed (STORTM): 90 day Storage time for egg animal feed (STORTM): 180 day Storage time for meat animal forage (STORTM): 0 day

Design Analyses and Calculation Page 57 of 125 Form Atkins-NS-EN-13-03 R3 Storage time for milk animal forage (STORTM): 0 day Fraction of diet for meat animal feed (DIETFR): 1 fraction Fraction of diet for poultry animal feed (DIETFR): 1 fraction Fraction of diet for milk animal feed (DIETFR): 1 fraction Fraction of diet for egg animal feed (DIETFR): 1 fraction Fraction of diet for meat animal forage (DIETFR): 1 fraction Fraction of diet for milk animal forage (DIETFR): 1 fraction Yield for leafy vegetables (YELD): 2 kg/m^2 Reference for YELD Reference ID #20

Reference:

Reg Guide 1.109 Table E-15 Agricultural Productivity Reference

Description:

0.7 kg/m^2 for grass-cow-milk-man pathway; 2.0 kg/m^2 for produce or leafy vegetables ingested by man Yield for root vegetables (YELD): 2 kg/m^2 Reference for YELD Reference ID #20

Reference:

Reg Guide 1.109 Table E-15 Agricultural Productivity Reference

Description:

0.7 kg/m^2 for grass-cow-milk-man pathway; 2.0 kg/m^2 for produce or leafy vegetables ingested by man Yield for fruits (YELD): 2 kg/m^2 Reference for YELD Reference ID #20

Reference:

Reg Guide 1.109 Table E-15 Agricultural Productivity Reference

Description:

0.7 kg/m^2 for grass-cow-milk-man pathway; 2.0 kg/m^2 for produce or leafy vegetables ingested by man Yield for grains (YELD): 2 kg/m^2 Reference for YELD Reference ID #20

Reference:

Reg Guide 1.109 Table E-15 Agricultural Productivity Reference

Description:

0.7 kg/m^2 for grass-cow-milk-man pathway; 2.0 kg/m^2 for produce or leafy vegetables ingested by man Time from harvest to ingestion for leafy vegetables (HLDUP): 1 day Reference for HLDUP Reference ID #21

Reference:

Reg Guide 1.109 Table E-15 Time deal ingestion of crops by man Reference

Description:

1 day for leafy vegetables and maximum individual; 60 days for produce and maximum individual Time from harvest to ingestion for root vegetables (HLDUP): 60 day Reference for HLDUP Reference ID #21

Reference:

Reg Guide 1.109 Table E-15 Time deal ingestion of crops by man Reference

Description:

1 day for leafy vegetables and maximum individual; 60 days for produce and maximum individual Time from harvest to ingestion for fruits (HLDUP): 60 day Reference for HLDUP Reference ID #21

Reference:

Reg Guide 1.109 Table E-15 Time deal ingestion of crops by man Reference

Description:

1 day for leafy vegetables and maximum individual; 60 days for produce and maximum individual Time from harvest to ingestion for grains (HLDUP): 60 day Reference for HLDUP Reference ID #21

Reference:

Reg Guide 1.109 Table E-15 Time deal ingestion of crops by man Reference

Description:

1 day for leafy vegetables and maximum individual; 60 days for produce and maximum individual Growing period for leafy vegetables (GRWP): 60 day Reference for GRWP Reference ID #19

Reference:

Reg Guide 1.109 Table E-15 Period of Growing Season Reference

Description:

30 days grass-cow-milk pathway; 60 days crops/vegetation-man pathway Growing period for root vegetables (GRWP): 60 day

Design Analyses and Calculation Page 58 of 125 Form Atkins-NS-EN-13-03 R3 Reference for GRWP Reference ID #19

Reference:

Reg Guide 1.109 Table E-15 Period of Growing Season Reference

Description:

30 days grass-cow-milk pathway; 60 days crops/vegetation-man pathway Growing period for fruits (GRWP): 60 day Reference for GRWP Reference ID #19

Reference:

Reg Guide 1.109 Table E-15 Period of Growing Season Reference

Description:

30 days grass-cow-milk pathway; 60 days crops/vegetation-man pathway Growing period for grains (GRWP): 60 day Reference for GRWP Reference ID #19

Reference:

Reg Guide 1.109 Table E-15 Period of Growing Season Reference

Description:

30 days grass-cow-milk pathway; 60 days crops/vegetation-man pathway Animal feed irrigation rate for meat animal feed (RIRRA): 35 in/yr Animal feed irrigation rate for poultry animal feed (RIRRA): 0 in/yr Animal feed irrigation rate for milk animal feed (RIRRA): 47 in/yr Animal feed irrigation rate for egg animal feed (RIRRA): 0 in/yr Animal feed irrigation rate for meat animal forage (RIRRA): 47 in/yr Animal feed irrigation rate for milk animal forage (RIRRA): 47 in/yr Animal feed irrigation time for meat animal feed (IRTIMA): 6 mon/yr Animal feed irrigation time for poultry animal feed (IRTIMA): 0 mon/yr Animal feed irrigation time for milk animal feed (IRTIMA): 6 mon/yr Animal feed irrigation time for egg animal feed (IRTIMA): 0 mon/yr Animal feed irrigation time for meat animal forage (IRTIMA): 6 mon/yr Animal feed irrigation time for milk animal forage (IRTIMA): 6 mon/yr Irrigation rate for leafy vegetables (RIRR): 35 in/yr Irrigation rate for root vegetables (RIRR): 40 in/yr Irrigation rate for fruits (RIRR): 35 in/yr Irrigation rate for grains (RIRR): 0 in/yr Irrigation time for leafy vegetables (IRTIMT): 6 mon/yr Irrigation time for root vegetables (IRTIMT): 6 mon/yr Irrigation time for fruits (IRTIMT): 6 mon/yr Irrigation time for grains (IRTIMT): 0 mon/yr Time from harvest to ingestion for fish (HLDUP2): 1 day Time from harvest to ingestion for mollusca (HLDUP2): 0 day Time from harvest to ingestion for crustacea (HLDUP2): 0 day Time from harvest to ingestion for aquatic plants (HLDUP2): 0 day Animal water contaminated fraction for meat animal (DWFACA): 1 fraction Animal water contaminated fraction for poultry animal (DWFACA): 1 fraction Animal water contaminated fraction for milk animal (DWFACA): 1 fraction Animal water contaminated fraction for egg animal (DWFACA): 1 fraction Surface soil density (SSLDN): 1600 kg/m^3 Reference for SSLDN Reference ID #16

Reference:

Based on assumed values for areal density and surface soil layer thickness Reference

Description:

[(240 kg/m^2)*(100 cm/m)]/(15 cm)

Irrigation rate for residential land (RIRRR): 35 in/yr Irrigation time for residential land (IRTIMR): 6 mon/yr Delay time in water distribution system (HOLDDW): 1 day Resuspension factor (RESFAC): 0.000000001 1/m Weathering rate constant from plants (WTIM): 14 d Reference for WTIM Reference ID #15

Reference:

Reg Guide 1.109 Table E-15 Reference

Description:

Dry deposition retention fraction to plants (DEPFR1): 1 fraction Reference for DEPFR1 Reference ID #15

Reference:

Reg Guide 1.109 Table E-15 Reference

Description:

Design Analyses and Calculation Page 59 of 125 Form Atkins-NS-EN-13-03 R3 Average daily rain rate (RAIN): 34.79 in/yr Reference for RAIN Reference ID #14

Reference:

Average from PSAR Tables 19.3.2-2 and 19.3.2-3 Reference

Description:

Average normal precipitation rates in in/yr from referenced tables.

Indoor volatilization factor for radon (ANDKRN): 0.1 l/m^3 Indoor volatilization factor for radionuclides (ANDKR): 0 l/m^3 Shoreline sediment density (SEDDN): 15 kg/m^2 Surface soil thickness (THICK): 15 cm Surface soil moisture content (MOISTC): 0.08 fraction Surface soil bulk density (BULKD): 1.5 g/cm^3 Total infiltration rate (VLEACH): 20 cm/yr Wet deposition retention fraction to plant surfaces (DEPFR2): 0.25 fraction Resuspension factor from soil to plant surfaces (LEAFRS): 0.000000001 1/m Deposition velocity from soil to plant surfaces (DPVRES): 0.001 m/s Surface soil areal density (SLDN): 240 kg/m^2 Reference for SLDN Reference ID #15

Reference:

Reg Guide 1.109 Table E-15 Reference

Description:

Surface soil layer thickness used for density (SURCM): 15 cm Reference for SURCM Reference ID #15

Reference:

Reg Guide 1.109 Table E-15 Reference

Description:

Intake rate of water for meat animal (DWATER): 50 L/d Intake rate of water for poultry animal (DWATER): 0.3 L/d Intake rate of water for milk animal (DWATER): 60 L/d Intake rate of water for egg animal (DWATER): 0.3 L/d Standing animal feed biomass (wet) for meat animal feed (BIOMA2): 1.6 kg/m^2 Standing animal feed biomass (wet) for poultry animal feed (BIOMA2): 1.6 kg/m^2 Standing animal feed biomass (wet) for milk animal feed (BIOMA2): 1 kg/m^2 Standing animal feed biomass (wet) for egg animal feed (BIOMA2): 1.6 kg/m^2 Standing animal feed biomass (wet) for meat animal forage (BIOMA2): 1 kg/m^2 Standing animal feed biomass (wet) for milk animal forage (BIOMA2): 1.5 kg/m^2 Consumption rate for meat animal feed (CONSUM): 17 kg/d Consumption rate for poultry animal feed (CONSUM): 0.12 kg/d Consumption rate for milk animal feed (CONSUM): 1.5 kg/d Reference for CONSUM Reference ID #28

Reference:

Regulatory Guide 1.109 Table E-3 goat consumption rate Reference

Description:

The Reg Guide 1.109 Table E-3 feed or forage rate of 6 kg/day for goats is divided between feed (hay) at 1.5 kg/d and forage (grass) at 4.5 kg/d for consistency with the GENII2 default split between feed and forage for cows of 14 kg/d and 41 kg/d.

Consumption rate for egg animal feed (CONSUM): 0.12 kg/d Consumption rate for meat animal forage (CONSUM): 51 kg/d Consumption rate for milk animal forage (CONSUM): 4.5 kg/d Reference for CONSUM Reference ID #28

Reference:

Regulatory Guide 1.109 Table E-3 goat consumption rate Reference

Description:

The Reg Guide 1.109 Table E-3 feed or forage rate of 6 kg/day for goats is divided between feed (hay) at 1.5 kg/d and forage (grass) at 4.5 kg/d for consistency with the GENII2 default split between feed and forage for cows of 14 kg/d and 41 kg/d.

Standing biomass (wet) for leafy vegetables (BIOMAS): 2 kg/m^2 Standing biomass (wet) for root vegetables (BIOMAS): 2 kg/m^2 Standing biomass (wet) for fruits (BIOMAS): 3 kg/m^2 Standing biomass (wet) for grains (BIOMAS): 1.6 kg/m^2 Translocation factor for animal feed for meat animal feed (TRANSA): 0.1 fraction Translocation factor for animal feed for poultry animal feed (TRANSA): 0.1 fraction Translocation factor for animal feed for milk animal feed (TRANSA): 1 fraction Translocation factor for animal feed for egg animal feed (TRANSA): 0.1 fraction

Design Analyses and Calculation Page 60 of 125 Form Atkins-NS-EN-13-03 R3 Translocation factor for animal feed for meat animal forage (TRANSA): 1 fraction Translocation factor for animal feed for milk animal forage (TRANSA): 1 fraction Translocation factor for leafy vegetables (TRANS): 1 fraction Translocation factor for root vegetables (TRANS): 0.1 fraction Translocation factor for fruits (TRANS): 0.1 fraction Translocation factor for grains (TRANS): 0.1 fraction Animal feed dry/wet ratio for meat animal feed (DRYFA2): 0.88 fraction Animal feed dry/wet ratio for poultry animal feed (DRYFA2): 0.88 fraction Animal feed dry/wet ratio for milk animal feed (DRYFA2): 0.2 fraction Animal feed dry/wet ratio for egg animal feed (DRYFA2): 0.88 fraction Animal feed dry/wet ratio for meat animal forage (DRYFA2): 0.2 fraction Animal feed dry/wet ratio for milk animal forage (DRYFA2): 0.2 fraction Dry/wet ratio for leafy vegetables (DRYFAC): 0.1 fraction Dry/wet ratio for root vegetables (DRYFAC): 0.2 fraction Dry/wet ratio for fruits (DRYFAC): 0.2 fraction Dry/wet ratio for grains (DRYFAC): 0.88 fraction Animal daily soil consumption rate for meat animal feed (SLCONA): 1 kg/d Animal daily soil consumption rate for poultry animal feed (SLCONA): 0.001 kg/d Animal daily soil consumption rate for milk animal feed (SLCONA): 1 kg/d Animal daily soil consumption rate for egg animal feed (SLCONA): 0.001 kg/d Number of constituents (NUMCON): 6 Chemical Abstract System Identification for I131 (CASID): I131 Soil adsorbtion coefficient for I131 (SOILKD): 15 ml/g Leach rate constant for I131 (LEACHR): 0 1/yr Progeny count for I131 (NDS): 1 Chemical Abstract System Identification for XE131m (CASID): XE131m Soil adsorbtion coefficient for XE131m (SOILKD): 0 ml/g Leach rate constant for XE131m (LEACHR): 0 1/yr Chemical Abstract System Identification for KR85 (CASID): KR85 Soil adsorbtion coefficient for KR85 (SOILKD): 0 ml/g Leach rate constant for KR85 (LEACHR): 0 1/yr Progeny count for KR85 (NDS): 0 Chemical Abstract System Identification for XE131m (CASID): XE131m Soil adsorbtion coefficient for XE131m (SOILKD): 0 ml/g Leach rate constant for XE131m (LEACHR): 0 1/yr Progeny count for XE131m (NDS): 0 Chemical Abstract System Identification for XE133 (CASID): XE133 Soil adsorbtion coefficient for XE133 (SOILKD): 0 ml/g Leach rate constant for XE133 (LEACHR): 0 1/yr Progeny count for XE133 (NDS): 0 Chemical Abstract System Identification for XE133m (CASID): XE133m Soil adsorbtion coefficient for XE133m (SOILKD): 0 ml/g Leach rate constant for XE133m (LEACHR): 0 1/yr Progeny count for XE133m (NDS): 1 Chemical Abstract System Identification for XE133 (CASID): XE133 Soil adsorbtion coefficient for XE133 (SOILKD): 0 ml/g Leach rate constant for XE133 (LEACHR): 0 1/yr Chemical Abstract System Identification for AR41 (CASID): AR41 Soil adsorbtion coefficient for AR41 (SOILKD): 0 ml/g Leach rate constant for AR41 (LEACHR): 0 1/yr Progeny count for AR41 (NDS): 0 Terrestrial animal product constant for Index# 1 (ANFLabel): meat animal Terrestrial animal product constant for Index# 2 (ANFLabel): poultry animal Terrestrial animal product constant for Index# 3 (ANFLabel): milk animal Terrestrial animal product constant for Index# 4 (ANFLabel): egg animal Plant product constant for Index# 1 (TFDLabel): leafy vegetables Plant product constant for Index# 2 (TFDLabel): root vegetables Plant product constant for Index# 3 (TFDLabel): fruits Plant product constant for Index# 4 (TFDLabel): grains Aquatic animal product constant for Index# 1 (AQFLabel): fish Aquatic animal product constant for Index# 2 (AQFLabel): mollusca

Design Analyses and Calculation Page 61 of 125 Form Atkins-NS-EN-13-03 R3 Aquatic animal product constant for Index# 3 (AQFLabel): crustacea Aquatic animal product constant for Index# 4 (AQFLabel): aquatic plants Feed animal constant for Index# 1 (FdFrLabel): meat animal feed Feed animal constant for Index# 2 (FdFrLabel): poultry animal feed Feed animal constant for Index# 3 (FdFrLabel): milk animal feed Feed animal constant for Index# 4 (FdFrLabel): egg animal feed Feed animal constant for Index# 5 (FdFrLabel): meat animal forage Feed animal constant for Index# 6 (FdFrLabel): milk animal forage

Design Analyses and Calculation Page 62 of 125 Form Atkins-NS-EN-13-03 R3 RECEPTOR INTAKES MODULE INPUT

  • File: c:\\frames\\shine\\nrgoat30.gid
  • Section: rcp13
  • Date: 3/18/2015 6:06:53 PM Number of age groups (NAGES): 4 Lower ager limit for age group # 1 (LOWAGE): 0 yr Upper age limit for age group # 1 (UPAGE): 1 yr Daily plume immersion exposure time for age group # 1 (UEXAIR): 24 hr Yearly plume immersion exposure time for age group # 1 (TEXAIR): 365 day Indoor shielding factor for age group # 0 (SHIN): 0.7 none Reference for SHIN Reference ID #23

Reference:

Reg Guide 1.109 TAble E-15 Attenuation Factor for shielding provided by residential structure Reference

Description:

Outdoor shielding factor for age group # 0 (SHOUT): 1 none Daily external ground exposure time for age group # 1 (UEXGRD): 24 hr Yearly external ground exposure time for age group # 1 (TEXGRD): 182.5 day Fraction of time spent indoors for age group # 1 (FTIN): 0.7 fraction Fraction of time spent outdoors for age group # 1 (FTOUT): 0.3 fraction Frequency of swimming event for age group # 1 (EVSWIM): 1 evt/day Duration of swimming event for age group # 1 (TESWIM): 2 hr Swimming days for age group # 1 (TSWIM): 50 day Ingestion rate of water while swimming for age group # 1 (USWIM): 0.02 L/hr Shielding factor for age group # 0 (SFBOAT): 1 none Frequency of boating event for age group # 1 (EVBOAT): 1 evt/day Duration of boating event for age group # 1 (TEBOAT): 2 hr Boating days for age group # 1 (TBOAT): 50 day Frequency of shoreline use for age group # 1 (EVSHOR): 1 evt/day Duration of shoreline use events for age group # 1 (TESHOR): 5 hr Shoreline days for age group # 1 (TSHOR): 100 day Shoreline width factor for age group # 0 (SWFAC): 0.2 none Crop consumption rate for leafy vegetables for age group # 1 (UCRP): 0 kg/day Reference for UCRP Reference ID #24

Reference:

Reg Guide 1.109 Table E-5 Infant Intake Reference

Description:

Milk: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d; Water: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d Crop consumption period for leafy vegetables for age group # 1 (TCRP): 0 day/yr Reference for TCRP Reference ID #24

Reference:

Reg Guide 1.109 Table E-5 Infant Intake Reference

Description:

Milk: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d; Water: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d Crop consumption rate for root vegetables for age group # 1 (UCRP): 0 kg/day Reference for UCRP Reference ID #24

Reference:

Reg Guide 1.109 Table E-5 Infant Intake Reference

Description:

Milk: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d; Water: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d Crop consumption period for root vegetables for age group # 1 (TCRP): 0 day/yr Reference for TCRP Reference ID #24

Reference:

Reg Guide 1.109 Table E-5 Infant Intake Reference

Description:

Milk: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d; Water: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d Crop consumption rate for fruits for age group # 1 (UCRP): 0 kg/day Reference for UCRP Reference ID #24

Design Analyses and Calculation Page 63 of 125 Form Atkins-NS-EN-13-03 R3

Reference:

Reg Guide 1.109 Table E-5 Infant Intake Reference

Description:

Milk: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d; Water: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d Crop consumption period for fruits for age group # 1 (TCRP): 0 day/yr Reference for TCRP Reference ID #24

Reference:

Reg Guide 1.109 Table E-5 Infant Intake Reference

Description:

Milk: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d; Water: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d Crop consumption rate for grains for age group # 1 (UCRP): 0 kg/day Reference for UCRP Reference ID #24

Reference:

Reg Guide 1.109 Table E-5 Infant Intake Reference

Description:

Milk: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d; Water: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d Crop consumption period for grains for age group # 1 (TCRP): 0 day/yr Reference for TCRP Reference ID #24

Reference:

Reg Guide 1.109 Table E-5 Infant Intake Reference

Description:

Milk: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d; Water: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d Animal product consumption rate for meat animal for age group # 1 (UANM): 0 kg/day Reference for UANM Reference ID #24

Reference:

Reg Guide 1.109 Table E-5 Infant Intake Reference

Description:

Milk: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d; Water: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d Animal product consumption period for meat animal for age group # 1 (TANM): 0 day/yr Reference for TANM Reference ID #24

Reference:

Reg Guide 1.109 Table E-5 Infant Intake Reference

Description:

Milk: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d; Water: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d Animal product consumption rate for poultry animal for age group # 1 (UANM): 0 kg/day Reference for UANM Reference ID #24

Reference:

Reg Guide 1.109 Table E-5 Infant Intake Reference

Description:

Milk: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d; Water: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d Animal product consumption period for poultry animal for age group # 1 (TANM): 0 day/yr Reference for TANM Reference ID #24

Reference:

Reg Guide 1.109 Table E-5 Infant Intake Reference

Description:

Milk: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d; Water: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d Animal product consumption rate for milk animal for age group # 1 (UANM): 0.904 kg/day Reference for UANM Reference ID #24

Reference:

Reg Guide 1.109 Table E-5 Infant Intake Reference

Description:

Milk: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d; Water: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d Animal product consumption period for milk animal for age group # 1 (TANM): 365 day/yr Animal product consumption rate for egg animal for age group # 1 (UANM): 0 kg/day Reference for UANM Reference ID #24

Reference:

Reg Guide 1.109 Table E-5 Infant Intake Reference

Description:

Milk: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d; Water: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d Animal product consumption period for egg animal for age group # 1 (TANM): 0 day/yr Reference for TANM Reference ID #24

Design Analyses and Calculation Page 64 of 125 Form Atkins-NS-EN-13-03 R3

Reference:

Reg Guide 1.109 Table E-5 Infant Intake Reference

Description:

Milk: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d; Water: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d Aquatic food consumption rate for fish for age group # 1 (UAQU): 1 kg/day Fish consumption period for fish for age group # 1 (TAQU): 365 day/yr Aquatic food consumption rate for mollusks for age group # 1 (UAQU): 0.019 kg/day Fish consumption period for mollusks for age group # 1 (TAQU): 365 day/yr Aquatic food consumption rate for crustacea for age group # 1 (UAQU): 0.019 kg/day Fish consumption period for crustacea for age group # 1 (TAQU): 365 day/yr Aquatic food consumption rate for aquatic plants for age group # 1 (UAQU): 0.019 kg/day Fish consumption period for aquatic plants for age group # 1 (TAQU): 365 day/yr Drinking water ingestion rate for age group # 1 (UDW): 0.904 L/day Reference for UDW Reference ID #24

Reference:

Reg Guide 1.109 Table E-5 Infant Intake Reference

Description:

Milk: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d; Water: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d Drinking water ingestion period for age group # 1 (TDW): 365 day/yr Freqency of showering event for age group # 1 (EVSHWR): 1 evt/day Duration of showering event for age group # 1 (TESHWR): 0.167 hr Showering days for age group # 1 (TSHWR): 365 day Ingestion rate of water while showering for age group # 1 (USHIN): 0.06 L/hr Soil contact days for age group # 1 (TSOIL): 365 day Inadvertent soil ingestion rate for age group # 1 (USOIL): 100 mg/day Air inhalation rate for age group # 1 (UINH): 1400 m^3/yr Reference for UINH Reference ID #24

Reference:

Reg Guide 1.109 Table E-5 Infant Intake Reference

Description:

Milk: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d; Water: 330 l/yr*1 kg/l*1 yr/365 days=0.904 kg/d Air inhalation period for age group # 1 (TINH): 365 day/yr Fraction of a day indoor inhalation occurs for age group # 1 (FRINH): 0.25 fraction Resuspended soil inhalation rate for age group # 1 (UINHR): 23 m^3/day Resuspended soil inhalation period for age group # 1 (TINHR): 365 day/yr Fraction of a day inhalation occurs for age group # 1 (FRINHR): 1 fraction Indoor air inhalation rate for age group # 1 (UINDRH): 1400 m^3/yr Indoor air inhalation period for age group # 1 (TINDRH): 365 day/yr Fraction of a day indoor inhalation occurs for age group # 1 (FRINDR): 0.75 fraction Lower ager limit for age group # 2 (LOWAGE): 1 yr Upper age limit for age group # 2 (UPAGE): 11 yr Daily plume immersion exposure time for age group # 2 (UEXAIR): 24 hr Yearly plume immersion exposure time for age group # 2 (TEXAIR): 365 day Daily external ground exposure time for age group # 2 (UEXGRD): 24 hr Yearly external ground exposure time for age group # 2 (TEXGRD): 182.5 day Fraction of time spent indoors for age group # 2 (FTIN): 0.7 fraction Fraction of time spent outdoors for age group # 2 (FTOUT): 0.3 fraction Frequency of swimming event for age group # 2 (EVSWIM): 1 evt/day Duration of swimming event for age group # 2 (TESWIM): 2 hr Swimming days for age group # 2 (TSWIM): 50 day Ingestion rate of water while swimming for age group # 2 (USWIM): 0.02 L/hr Frequency of boating event for age group # 2 (EVBOAT): 1 evt/day Duration of boating event for age group # 2 (TEBOAT): 2 hr Boating days for age group # 2 (TBOAT): 50 day Frequency of shoreline use for age group # 2 (EVSHOR): 1 evt/day Duration of shoreline use events for age group # 2 (TESHOR): 5 hr Shoreline days for age group # 2 (TSHOR): 100 day Crop consumption rate for leafy vegetables for age group # 2 (UCRP): 26 kg/yr Reference for UCRP Reference ID #25

Reference:

Reg Guide 1.109 Table E-5 Child Consumption

Design Analyses and Calculation Page 65 of 125 Form Atkins-NS-EN-13-03 R3 Reference

Description:

Fruit: 0.22*520 kg/yr=114.4 kg/yr; Grain: 0.24*520 kg/yr=124.8 kg/yr; Vegetables: 0.54*520 kg/yr=280.8 kg/yr Crop consumption period for leafy vegetables for age group # 2 (TCRP): 365 day/yr Crop consumption rate for root vegetables for age group # 2 (UCRP): 280.8 kg/yr Reference for UCRP Reference ID #25

Reference:

Reg Guide 1.109 Table E-5 Child Consumption Reference

Description:

Fruit: 0.22*520 kg/yr=114.4 kg/yr; Grain: 0.24*520 kg/yr=124.8 kg/yr; Vegetables: 0.54*520 kg/yr=280.8 kg/yr Crop consumption period for root vegetables for age group # 2 (TCRP): 365 day/yr Crop consumption rate for fruits for age group # 2 (UCRP): 114.4 kg/yr Reference for UCRP Reference ID #25

Reference:

Reg Guide 1.109 Table E-5 Child Consumption Reference

Description:

Fruit: 0.22*520 kg/yr=114.4 kg/yr; Grain: 0.24*520 kg/yr=124.8 kg/yr; Vegetables: 0.54*520 kg/yr=280.8 kg/yr Crop consumption period for fruits for age group # 2 (TCRP): 365 day/yr Crop consumption rate for grains for age group # 2 (UCRP): 124.8 kg/yr Reference for UCRP Reference ID #25

Reference:

Reg Guide 1.109 Table E-5 Child Consumption Reference

Description:

Fruit: 0.22*520 kg/yr=114.4 kg/yr; Grain: 0.24*520 kg/yr=124.8 kg/yr; Vegetables: 0.54*520 kg/yr=280.8 kg/yr Crop consumption period for grains for age group # 2 (TCRP): 365 day/yr Animal product consumption rate for meat animal for age group # 2 (UANM): 41 kg/yr Reference for UANM Reference ID #25

Reference:

Reg Guide 1.109 Table E-5 Child Consumption Reference

Description:

Fruit: 0.22*520 kg/yr=114.4 kg/yr; Grain: 0.24*520 kg/yr=124.8 kg/yr; Vegetables: 0.54*520 kg/yr=280.8 kg/yr Animal product consumption period for meat animal for age group # 2 (TANM): 365 day/yr Animal product consumption rate for poultry animal for age group # 2 (UANM): 0.049 kg/day Animal product consumption period for poultry animal for age group # 2 (TANM): 365 day/yr Animal product consumption rate for milk animal for age group # 2 (UANM): 0.9 kg/day Reference for UANM Reference ID #25

Reference:

Reg Guide 1.109 Table E-5 Child Consumption Reference

Description:

Fruit: 0.22*520 kg/yr=114.4 kg/yr; Grain: 0.24*520 kg/yr=124.8 kg/yr; Vegetables: 0.54*520 kg/yr=280.8 kg/yr Animal product consumption period for milk animal for age group # 2 (TANM): 365 day/yr Animal product consumption rate for egg animal for age group # 2 (UANM): 0.032 kg/day Animal product consumption period for egg animal for age group # 2 (TANM): 365 day/yr Aquatic food consumption rate for fish for age group # 2 (UAQU): 0.11 kg/day Fish consumption period for fish for age group # 2 (TAQU): 365 day/yr Aquatic food consumption rate for mollusks for age group # 2 (UAQU): 0.019 kg/day Fish consumption period for mollusks for age group # 2 (TAQU): 365 day/yr Aquatic food consumption rate for crustacea for age group # 2 (UAQU): 0.019 kg/day Fish consumption period for crustacea for age group # 2 (TAQU): 365 day/yr Aquatic food consumption rate for aquatic plants for age group # 2 (UAQU): 0.019 kg/day Fish consumption period for aquatic plants for age group # 2 (TAQU): 365 day/yr Drinking water ingestion rate for age group # 2 (UDW): 2 L/day Drinking water ingestion period for age group # 2 (TDW): 365 day/yr Freqency of showering event for age group # 2 (EVSHWR): 1 evt/day Duration of showering event for age group # 2 (TESHWR): 0.167 hr Showering days for age group # 2 (TSHWR): 365 day Ingestion rate of water while showering for age group # 2 (USHIN): 0.06 L/hr Soil contact days for age group # 2 (TSOIL): 365 day Inadvertent soil ingestion rate for age group # 2 (USOIL): 100 mg/day Air inhalation rate for age group # 2 (UINH): 3700 m^3/yr Reference for UINH Reference ID #25

Design Analyses and Calculation Page 66 of 125 Form Atkins-NS-EN-13-03 R3

Reference:

Reg Guide 1.109 Table E-5 Child Consumption Reference

Description:

Fruit: 0.22*520 kg/yr=114.4 kg/yr; Grain: 0.24*520 kg/yr=124.8 kg/yr; Vegetables: 0.54*520 kg/yr=280.8 kg/yr Air inhalation period for age group # 2 (TINH): 365 day/yr Fraction of a day indoor inhalation occurs for age group # 2 (FRINH): 0.25 fraction Resuspended soil inhalation rate for age group # 2 (UINHR): 23 m^3/day Resuspended soil inhalation period for age group # 2 (TINHR): 365 day/yr Fraction of a day inhalation occurs for age group # 2 (FRINHR): 1 fraction Indoor air inhalation rate for age group # 2 (UINDRH): 3700 m^3/yr Reference for UINDRH Reference ID #25

Reference:

Reg Guide 1.109 Table E-5 Child Consumption Reference

Description:

Fruit: 0.22*520 kg/yr=114.4 kg/yr; Grain: 0.24*520 kg/yr=124.8 kg/yr; Vegetables: 0.54*520 kg/yr=280.8 kg/yr Indoor air inhalation period for age group # 2 (TINDRH): 365 day/yr Fraction of a day indoor inhalation occurs for age group # 2 (FRINDR): 0.75 fraction Lower ager limit for age group # 3 (LOWAGE): 11 yr Upper age limit for age group # 3 (UPAGE): 17 yr Daily plume immersion exposure time for age group # 3 (UEXAIR): 24 hr Yearly plume immersion exposure time for age group # 3 (TEXAIR): 365 day Daily external ground exposure time for age group # 3 (UEXGRD): 24 hr Yearly external ground exposure time for age group # 3 (TEXGRD): 182.5 day Fraction of time spent indoors for age group # 3 (FTIN): 0.7 fraction Fraction of time spent outdoors for age group # 3 (FTOUT): 0.3 fraction Frequency of swimming event for age group # 3 (EVSWIM): 1 evt/day Duration of swimming event for age group # 3 (TESWIM): 2 hr Swimming days for age group # 3 (TSWIM): 50 day Ingestion rate of water while swimming for age group # 3 (USWIM): 0.02 L/hr Frequency of boating event for age group # 3 (EVBOAT): 1 evt/day Duration of boating event for age group # 3 (TEBOAT): 2 hr Boating days for age group # 3 (TBOAT): 50 day Frequency of shoreline use for age group # 3 (EVSHOR): 1 evt/day Duration of shoreline use events for age group # 3 (TESHOR): 5 hr Shoreline days for age group # 3 (TSHOR): 100 day Crop consumption rate for leafy vegetables for age group # 3 (UCRP): 42 kg/yr Reference for UCRP Reference ID #26

Reference:

Reg Guide 1.109 Table E-5 Teen Consumption Reference

Description:

Fruit: 0.22*630 kg/yr=138.6 kg/yr; Grain 0.24*630 kg/yr=151.2 kg/yr; Vegetables 0.54*630 kg/yr=340.2 kg/yr (assumed to be root vegetables)

Crop consumption period for leafy vegetables for age group # 3 (TCRP): 365 day/yr Crop consumption rate for root vegetables for age group # 3 (UCRP): 340.2 kg/yr Reference for UCRP Reference ID #26

Reference:

Reg Guide 1.109 Table E-5 Teen Consumption Reference

Description:

Fruit: 0.22*630 kg/yr=138.6 kg/yr; Grain 0.24*630 kg/yr=151.2 kg/yr; Vegetables 0.54*630 kg/yr=340.2 kg/yr (assumed to be root vegetables)

Crop consumption period for root vegetables for age group # 3 (TCRP): 365 day/yr Crop consumption rate for fruits for age group # 3 (UCRP): 138.6 kg/yr Reference for UCRP Reference ID #26

Reference:

Reg Guide 1.109 Table E-5 Teen Consumption Reference

Description:

Fruit: 0.22*630 kg/yr=138.6 kg/yr; Grain 0.24*630 kg/yr=151.2 kg/yr; Vegetables 0.54*630 kg/yr=340.2 kg/yr (assumed to be root vegetables)

Crop consumption period for fruits for age group # 3 (TCRP): 365 day/yr Crop consumption rate for grains for age group # 3 (UCRP): 151.2 kg/yr Reference for UCRP Reference ID #26

Reference:

Reg Guide 1.109 Table E-5 Teen Consumption Reference

Description:

Fruit: 0.22*630 kg/yr=138.6 kg/yr; Grain 0.24*630 kg/yr=151.2 kg/yr; Vegetables 0.54*630 kg/yr=340.2 kg/yr (assumed to be root vegetables)

Design Analyses and Calculation Page 67 of 125 Form Atkins-NS-EN-13-03 R3 Crop consumption period for grains for age group # 3 (TCRP): 365 day/yr Animal product consumption rate for meat animal for age group # 3 (UANM): 65 kg/yr Reference for UANM Reference ID #26

Reference:

Reg Guide 1.109 Table E-5 Teen Consumption Reference

Description:

Fruit: 0.22*630 kg/yr=138.6 kg/yr; Grain 0.24*630 kg/yr=151.2 kg/yr; Vegetables 0.54*630 kg/yr=340.2 kg/yr (assumed to be root vegetables)

Animal product consumption period for meat animal for age group # 3 (TANM): 365 day/yr Animal product consumption rate for poultry animal for age group # 3 (UANM): 0.049 kg/day Animal product consumption period for poultry animal for age group # 3 (TANM): 365 day/yr Animal product consumption rate for milk animal for age group # 3 (UANM): 1.1 kg/day Reference for UANM Reference ID #26

Reference:

Reg Guide 1.109 Table E-5 Teen Consumption Reference

Description:

Fruit: 0.22*630 kg/yr=138.6 kg/yr; Grain 0.24*630 kg/yr=151.2 kg/yr; Vegetables 0.54*630 kg/yr=340.2 kg/yr (assumed to be root vegetables)

Animal product consumption period for milk animal for age group # 3 (TANM): 365 day/yr Animal product consumption rate for egg animal for age group # 3 (UANM): 0.032 kg/day Animal product consumption period for egg animal for age group # 3 (TANM): 365 day/yr Aquatic food consumption rate for fish for age group # 3 (UAQU): 0.11 kg/day Fish consumption period for fish for age group # 3 (TAQU): 365 day/yr Aquatic food consumption rate for mollusks for age group # 3 (UAQU): 0.019 kg/day Fish consumption period for mollusks for age group # 3 (TAQU): 365 day/yr Aquatic food consumption rate for crustacea for age group # 3 (UAQU): 0.019 kg/day Fish consumption period for crustacea for age group # 3 (TAQU): 365 day/yr Aquatic food consumption rate for aquatic plants for age group # 3 (UAQU): 0.019 kg/day Fish consumption period for aquatic plants for age group # 3 (TAQU): 365 day/yr Drinking water ingestion rate for age group # 3 (UDW): 2 L/day Drinking water ingestion period for age group # 3 (TDW): 365 day/yr Freqency of showering event for age group # 3 (EVSHWR): 1 evt/day Duration of showering event for age group # 3 (TESHWR): 0.167 hr Showering days for age group # 3 (TSHWR): 365 day Ingestion rate of water while showering for age group # 3 (USHIN): 0.06 L/hr Soil contact days for age group # 3 (TSOIL): 365 day Inadvertent soil ingestion rate for age group # 3 (USOIL): 100 mg/day Air inhalation rate for age group # 3 (UINH): 8000 m^3/yr Reference for UINH Reference ID #26

Reference:

Reg Guide 1.109 Table E-5 Teen Consumption Reference

Description:

Fruit: 0.22*630 kg/yr=138.6 kg/yr; Grain 0.24*630 kg/yr=151.2 kg/yr; Vegetables 0.54*630 kg/yr=340.2 kg/yr (assumed to be root vegetables)

Air inhalation period for age group # 3 (TINH): 365 day/yr Fraction of a day indoor inhalation occurs for age group # 3 (FRINH): 0.25 fraction Resuspended soil inhalation rate for age group # 3 (UINHR): 23 m^3/day Resuspended soil inhalation period for age group # 3 (TINHR): 365 day/yr Fraction of a day inhalation occurs for age group # 3 (FRINHR): 1 fraction Indoor air inhalation rate for age group # 3 (UINDRH): 8000 m^3/yr Reference for UINDRH Reference ID #26

Reference:

Reg Guide 1.109 Table E-5 Teen Consumption Reference

Description:

Fruit: 0.22*630 kg/yr=138.6 kg/yr; Grain 0.24*630 kg/yr=151.2 kg/yr; Vegetables 0.54*630 kg/yr=340.2 kg/yr (assumed to be root vegetables)

Indoor air inhalation period for age group # 3 (TINDRH): 365 day/yr Fraction of a day indoor inhalation occurs for age group # 3 (FRINDR): 0.75 fraction Lower ager limit for age group # 4 (LOWAGE): 17 yr Upper age limit for age group # 4 (UPAGE): 70 yr Daily plume immersion exposure time for age group # 4 (UEXAIR): 24 hr Yearly plume immersion exposure time for age group # 4 (TEXAIR): 365 day Daily external ground exposure time for age group # 4 (UEXGRD): 24 hr Yearly external ground exposure time for age group # 4 (TEXGRD): 182.5 day Fraction of time spent indoors for age group # 4 (FTIN): 0.7 fraction

Design Analyses and Calculation Page 68 of 125 Form Atkins-NS-EN-13-03 R3 Fraction of time spent outdoors for age group # 4 (FTOUT): 0.3 fraction Frequency of swimming event for age group # 4 (EVSWIM): 1 evt/day Duration of swimming event for age group # 4 (TESWIM): 2 hr Swimming days for age group # 4 (TSWIM): 50 day Ingestion rate of water while swimming for age group # 4 (USWIM): 0.02 L/hr Frequency of boating event for age group # 4 (EVBOAT): 1 evt/day Duration of boating event for age group # 4 (TEBOAT): 2 hr Boating days for age group # 4 (TBOAT): 50 day Frequency of shoreline use for age group # 4 (EVSHOR): 1 evt/day Duration of shoreline use events for age group # 4 (TESHOR): 5 hr Shoreline days for age group # 4 (TSHOR): 100 day Crop consumption rate for leafy vegetables for age group # 4 (UCRP): 54 kg/yr Reference for UCRP Reference ID #27

Reference:

Reg Guide 1.109 Table E-15 Adult Consumption Reference

Description:

Fruit: 0.22*520 kg/yr=114.4 kg/yr; Grain 0.24*520 kg/yr=124.8 kg/yr; Vegetables 0.54*520 kg/yr=280.8 kg/yr (assumed to be root vegetables)

Crop consumption period for leafy vegetables for age group # 4 (TCRP): 365 day/yr Crop consumption rate for root vegetables for age group # 4 (UCRP): 280.8 kg/yr Reference for UCRP Reference ID #27

Reference:

Reg Guide 1.109 Table E-15 Adult Consumption Reference

Description:

Fruit: 0.22*520 kg/yr=114.4 kg/yr; Grain 0.24*520 kg/yr=124.8 kg/yr; Vegetables 0.54*520 kg/yr=280.8 kg/yr (assumed to be root vegetables)

Crop consumption period for root vegetables for age group # 4 (TCRP): 365 day/yr Crop consumption rate for fruits for age group # 4 (UCRP): 114.4 kg/yr Reference for UCRP Reference ID #27

Reference:

Reg Guide 1.109 Table E-15 Adult Consumption Reference

Description:

Fruit: 0.22*520 kg/yr=114.4 kg/yr; Grain 0.24*520 kg/yr=124.8 kg/yr; Vegetables 0.54*520 kg/yr=280.8 kg/yr (assumed to be root vegetables)

Crop consumption period for fruits for age group # 4 (TCRP): 365 day/yr Crop consumption rate for grains for age group # 4 (UCRP): 124.8 kg/yr Reference for UCRP Reference ID #27

Reference:

Reg Guide 1.109 Table E-15 Adult Consumption Reference

Description:

Fruit: 0.22*520 kg/yr=114.4 kg/yr; Grain 0.24*520 kg/yr=124.8 kg/yr; Vegetables 0.54*520 kg/yr=280.8 kg/yr (assumed to be root vegetables)

Crop consumption period for grains for age group # 4 (TCRP): 365 day/yr Animal product consumption rate for meat animal for age group # 4 (UANM): 110 kg/yr Reference for UANM Reference ID #27

Reference:

Reg Guide 1.109 Table E-15 Adult Consumption Reference

Description:

Fruit: 0.22*520 kg/yr=114.4 kg/yr; Grain 0.24*520 kg/yr=124.8 kg/yr; Vegetables 0.54*520 kg/yr=280.8 kg/yr (assumed to be root vegetables)

Animal product consumption period for meat animal for age group # 4 (TANM): 365 day/yr Animal product consumption rate for poultry animal for age group # 4 (UANM): 0.049 kg/day Animal product consumption period for poultry animal for age group # 4 (TANM): 365 day/yr Animal product consumption rate for milk animal for age group # 4 (UANM): 0.84 kg/day Animal product consumption period for milk animal for age group # 4 (TANM): 365 day/yr Animal product consumption rate for egg animal for age group # 4 (UANM): 0.032 kg/day Animal product consumption period for egg animal for age group # 4 (TANM): 365 day/yr Aquatic food consumption rate for fish for age group # 4 (UAQU): 0.11 kg/day Fish consumption period for fish for age group # 4 (TAQU): 365 day/yr Aquatic food consumption rate for mollusks for age group # 4 (UAQU): 0.019 kg/day Fish consumption period for mollusks for age group # 4 (TAQU): 365 day/yr Aquatic food consumption rate for crustacea for age group # 4 (UAQU): 0.019 kg/day Fish consumption period for crustacea for age group # 4 (TAQU): 365 day/yr Aquatic food consumption rate for aquatic plants for age group # 4 (UAQU): 0.019 kg/day Fish consumption period for aquatic plants for age group # 4 (TAQU): 365 day/yr Drinking water ingestion rate for age group # 4 (UDW): 2 L/day

Design Analyses and Calculation Page 69 of 125 Form Atkins-NS-EN-13-03 R3 Drinking water ingestion period for age group # 4 (TDW): 365 day/yr Freqency of showering event for age group # 4 (EVSHWR): 1 evt/day Duration of showering event for age group # 4 (TESHWR): 0.167 hr Showering days for age group # 4 (TSHWR): 365 day Ingestion rate of water while showering for age group # 4 (USHIN): 0.06 L/hr Soil contact days for age group # 4 (TSOIL): 365 day Inadvertent soil ingestion rate for age group # 4 (USOIL): 100 mg/day Air inhalation rate for age group # 4 (UINH): 8000 m^3/yr Reference for UINH Reference ID #27

Reference:

Reg Guide 1.109 Table E-15 Adult Consumption Reference

Description:

Fruit: 0.22*520 kg/yr=114.4 kg/yr; Grain 0.24*520 kg/yr=124.8 kg/yr; Vegetables 0.54*520 kg/yr=280.8 kg/yr (assumed to be root vegetables)

Air inhalation period for age group # 4 (TINH): 365 day/yr Fraction of a day indoor inhalation occurs for age group # 4 (FRINH): 0.25 fraction Resuspended soil inhalation rate for age group # 4 (UINHR): 23 m^3/day Resuspended soil inhalation period for age group # 4 (TINHR): 365 day/yr Fraction of a day inhalation occurs for age group # 4 (FRINHR): 1 fraction Indoor air inhalation rate for age group # 4 (UINDRH): 8000 m^3/yr Reference for UINDRH Reference ID #27

Reference:

Reg Guide 1.109 Table E-15 Adult Consumption Reference

Description:

Fruit: 0.22*520 kg/yr=114.4 kg/yr; Grain 0.24*520 kg/yr=124.8 kg/yr; Vegetables 0.54*520 kg/yr=280.8 kg/yr (assumed to be root vegetables)

Indoor air inhalation period for age group # 4 (TINDRH): 365 day/yr Fraction of a day indoor inhalation occurs for age group # 4 (FRINDR): 0.75 fraction Terrestrial animal product constant for Index# 1 (ANFLabel): meat animal Terrestrial animal product constant for Index# 2 (ANFLabel): poultry animal Terrestrial animal product constant for Index# 3 (ANFLabel): milk animal Terrestrial animal product constant for Index# 4 (ANFLabel): egg animal Plant product constant for Index# 1 (TFDLabel): leafy vegetables Plant product constant for Index# 2 (TFDLabel): root vegetables Plant product constant for Index# 3 (TFDLabel): fruits Plant product constant for Index# 4 (TFDLabel): grains Aquatic animal product constant for Index# 1 (AQFLabel): fish Aquatic animal product constant for Index# 2 (AQFLabel): mollusks Aquatic animal product constant for Index# 3 (AQFLabel): crustacea Aquatic animal product constant for Index# 4 (AQFLabel): aquatic plants

Design Analyses and Calculation Page 70 of 125 Form Atkins-NS-EN-13-03 R3 HEALTH IMPACTS MODULE INPUT

  • File: c:\\frames\\shine\\nrgoat30.gid
  • Section: hei14
  • Date: 3/18/2015 6:07:30 PM

? (FGR13): False

? (METHOD): 0

? (IHEAST): 0 Calculate lifetime cancer incidence (HEINC): False Calculate cancer fatalities (HEFAT): False Calculate radiation effective dose equivalent commitment (HECEDE): True Thickness of contaminated soil/sediment layer (SOILT): 0.15 m Reference for SOILT Reference ID #15

Reference:

Reg Guide 1.109 Table E-15 Reference

Description:

Density of contaminated soil/sediment layer (SLDN): 1600 kg/m^3 Reference for SLDN Reference ID #16

Reference:

Based on assumed values for areal density and surface soil layer thickness Reference

Description:

[(240 kg/m^2)*(100 cm/m)]/(15 cm)

Number of constituents (NUMCON): 6

Design Analyses and Calculation Page 71 of 125 Form Atkins-NS-EN-13-03 R3 APPENDIX 2: OUTPUT FILES

Design Analyses and Calculation Page 72 of 125 Form Atkins-NS-EN-13-03 R3 GOAT MILK OUTPUT FILE - MEI

  • File: c:\\frames\\shine\\sbgoat30.epa
  • Section: nes15
  • Date: 3/18/2015 6:15:42 PM GENII VERSION 2

SUMMARY

REPORT FOR CASE: c:\\frames\\shine\\sbgoat30 -----------------------------

FOR IMPACT ICON: hei14 THE HEALTH IMPACTS FILE FOR THIS CASE CONTAINS INFORMATION ON:

4 AGE GROUP(S) 6 RADIONUCLIDES (COUNTING DECAY PROGENY SEPARATELY IN CHAINS) 1 ORGAN(S)/TISSUE(S) FOR RADIATION DOSE 1 POTENTIAL CANCER SITES

SUMMARY

OF CASE INPUT DATA ---------------------------------------------------------------------------

SUMMARY

OF INPUT DATA FOR ATMOSPHERIC RELEASES -------------------------------------------------------

FOR LOCATION usr9 THE RELEASE IS Point EXIT AREA, M2: 1.00E-01 EXIT HEIGHT, M: 1.00E+01 HEIGHT OF ADJACENT BUILDING, M: 1.00E+01 EXIT VELOCITY, M/S: 0.00E+00 EXIT TEMPERATURE, DEGREE C: 9.30E+00 AMBIENT TEMPERATURE, DEGREE C; 9.30E+00 RELEASE MEDIUM 1 IS A GAS WITH NON-DEPOSITING FRACTION 5.00E-01 RELEASE PARTICLE 2 HAS RADIUS 3.00E+00 um RADIONUCLIDE TIME GAS PARTICLE 1 PARTICLE 2 PARTICLE 3 RELEASE RATE (yr) (pCi/yr) (pCi/yr) (pCi/yr) (pCi/yr)

AR41 0.00E+00 1.52E+13 0.00E+00 0.00E+00 0.00E+00 1.00E+00 1.52E+13 0.00E+00 0.00E+00 0.00E+00 I131 0.00E+00 6.65E+11 2.85E+11 0.00E+00 0.00E+00 1.00E+00 6.65E+11 2.85E+11 0.00E+00 0.00E+00 KR85 0.00E+00 1.20E+14 0.00E+00 0.00E+00 0.00E+00 1.00E+00 1.20E+14 0.00E+00 0.00E+00 0.00E+00 XE131m 0.00E+00 5.53E+14 0.00E+00 0.00E+00 0.00E+00 1.00E+00 5.53E+14 0.00E+00 0.00E+00 0.00E+00 XE133 0.00E+00 1.08E+16 0.00E+00 0.00E+00 0.00E+00 1.00E+00 1.08E+16 0.00E+00 0.00E+00 0.00E+00 XE133m 0.00E+00 4.08E+11 0.00E+00 0.00E+00 0.00E+00 1.00E+00 4.08E+11 0.00E+00 0.00E+00 0.00E+00

SUMMARY

OF ATMOSPHERIC TRANSPORT RESULTS FOR MODULE air10 ------------------

METEOROLOGICAL DATA TAKEN FROM FILE: NOT FOUND DISPERSION PARAMETERIZATION 0 data set was not found, NLINES =$__7 MINIMUM WIND SPEED DURING PLUME RISE 0.00 M/S

Design Analyses and Calculation Page 73 of 125 Form Atkins-NS-EN-13-03 R3 SIGMA TO SHIFT TO SEMI-INFINITE CLOUD SHINE 0.00 M TRANSFER RESISTENCE FOR IODINE 0.00 S/M TRANSFER RESISTENCE FOR PARTICLES 0.00 S/M MAXIMUM WIND SPEED FOR CALM 0.00 M/S

SUMMARY

OF INPUT DATA FOR EXPOSURE MODULE exp12 ------------------------

TERRESTRIAL ACCUMULATION TIME LINE:

START OF RELEASE (YEARS BEFORE INITIAL EXPOSURE): 15.

DURATION OF RELEASE (YEARS SINCE INITIAL RELEASE): 30.

DURATION OF EXPOSURE (YEARS): 1.

GENERAL ENVIRONMENTAL BEHAVIOR CONTROLS:

TYPE OF RESUSPENSION MODEL: None TYPE OF SOIL LEACHING MODEL: Calculated From User Input TYPE OF AIR SUBMERSION MODEL: Infinite Plume INADVERTANT SOIL INGESTION PATHWAY: ON ESTIMATION OF INDOOR AIR CONCENTRATIONS: ON ESTIMATION OF OUTDOOR SOIL EXTERNAL DOSE RATES: ON HARVEST REMOVAL OF CONTAMINANTS FROM SOIL: ON ABSOLUTE HUMIDITY FOR H-3 CALCULATIONS, KG/M3: 8.00E-03 FRACTION OF ROOTS IN SURFACE SOILS: 1.00E+00 SURFACE SOIL DENSITY, KG/M3: 1.60E+03 WEATHERING RATE HALF-TIME FOR VEGETATION, DAYS: 1.40E+01 AVERAGE RAINFALL RATE (WHEN RAINING), MM/DAY: 2.42E+00 RESUSPENSION FACTOR FOR SOIL-TO-PLANT, 1/M: 1.00E-09 LOCAL DEPOSITION VELOCITY FOR RESUSPENDED SOIL, M/S: 1.00E-03 SURFACE SOIL AREAL DENSITY, KG/M2: 2.40E+02 SURFACE SOIL LAYER THICKNESS, M: 1.50E+01 GROW STANDING YIELD INTAKE DRY-TO-WET TRANSLOCATION TIME BIOMASS (KG/M2) DELAY RATIO FACTOR TERRESTRIAL FOODS (DAYS) (KG/M2) (DAYS)

LEAFY VEG 60. 2.00 2.00 1.00 0.10 1.00 OTHER VEG 60. 2.00 2.00 60.00 0.20 0.10 FRUIT 60. 3.00 2.00 60.00 0.20 0.10 GRAIN 60. 1.60 2.00 60.00 0.88 0.10 GROW STANDING YIELD STORAGE DRY-TO-WET TRANSLOCATION DIET CONSUMPTION SOIL INTAKE TIME BIOMASS (KG/M2) TIME RATIO FACTOR FRACTION RATE INTAKE DELAY ANIMAL PRODUCTS (DAYS) (KG/M2) (DAYS) (KG/D) (KG/D) (DAYS)

STORED FEED MEAT 90. 1.60 0.80 90.00 0.88 0.10 1.00 17.00 1.00 20.00 POULTRY 90. 1.60 0.80 180.00 0.88 0.10 1.00 0.12 0.00 1.00 MILK 30. 1.00 0.70 90.00 0.20 1.00 1.00 1.50 1.00 1.00 EGGS 90. 1.60 0.80 180.00 0.88 0.10 1.00 0.12 0.00 1.00 FRESH FORAGE MEAT ANIMAL 45. 1.00 2.00 0.00 0.20 1.00 1.00 51.00 MILK COW 30. 1.50 0.70 0.00 0.20 1.00 1.00 4.50

SUMMARY

OF INPUT DATA FROM RECEPTOR MODULE rcp13 -------------------------

Design Analyses and Calculation Page 74 of 125 Form Atkins-NS-EN-13-03 R3 FOR AGE GROUP 1 THE LOWER AGE LIMIT IS 0.0 AND THE UPPER AGE LIMIT IS 1.0 YEARS.

FOR AGE GROUP 2 THE LOWER AGE LIMIT IS 1.0 AND THE UPPER AGE LIMIT IS 11.0 YEARS.

FOR AGE GROUP 3 THE LOWER AGE LIMIT IS 11.0 AND THE UPPER AGE LIMIT IS 17.0 YEARS.

FOR AGE GROUP 4 THE LOWER AGE LIMIT IS 17.0 AND THE UPPER AGE LIMIT IS 70.0 YEARS.

FOR AGE GROUP 1 DAILY PLUME IMMERSION EXPOSURE TIME IS 24.0 HOURS/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 2 DAILY PLUME IMMERSION EXPOSURE TIME IS 24.0 HOURS/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 DAILY PLUME IMMERSION EXPOSURE TIME IS 24.0 HOURS/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 DAILY PLUME IMMERSION EXPOSURE TIME IS 24.0 HOURS/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 DAILY SOIL EXTERNAL EXPOSURE TIME IS 24.0 HOURS/DAY FOR 182.5 DAYS/YEAR, WITH FRACTIONS OF TIME INDOORS/OUTDOORS OF 0.700/0.300 FOR AGE GROUP 2 DAILY SOIL EXTERNAL EXPOSURE TIME IS 24.0 HOURS/DAY FOR 182.5 DAYS/YEAR, WITH FRACTIONS OF TIME INDOORS/OUTDOORS OF 0.700/0.300 FOR AGE GROUP 3 DAILY SOIL EXTERNAL EXPOSURE TIME IS 24.0 HOURS/DAY FOR 182.5 DAYS/YEAR, WITH FRACTIONS OF TIME INDOORS/OUTDOORS OF 0.700/0.300 FOR AGE GROUP 4 DAILY SOIL EXTERNAL EXPOSURE TIME IS 24.0 HOURS/DAY FOR 182.5 DAYS/YEAR, WITH FRACTIONS OF TIME INDOORS/OUTDOORS OF 0.700/0.300 THE SHIELDING FACTORS FOR INDOOR AND OUTDOOR EXPOSURE ARE 0.700 AND 1.000 FOR AGE GROUP 1 CONSUMPTION OF LEAFY VEG IS 0.000 KG/DAY FOR 0.0 DAYS/YEAR FOR AGE GROUP 2 CONSUMPTION OF LEAFY VEG IS 0.071 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 CONSUMPTION OF LEAFY VEG IS 0.115 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 CONSUMPTION OF LEAFY VEG IS 0.148 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 CONSUMPTION OF OTHER VEG IS 0.000 KG/DAY FOR 0.0 DAYS/YEAR FOR AGE GROUP 2 CONSUMPTION OF OTHER VEG IS 0.769 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 CONSUMPTION OF OTHER VEG IS 0.931 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 CONSUMPTION OF OTHER VEG IS 0.769 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 CONSUMPTION OF FRUIT IS 0.000 KG/DAY FOR 0.0 DAYS/YEAR FOR AGE GROUP 2 CONSUMPTION OF FRUIT IS 0.313 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 CONSUMPTION OF FRUIT IS 0.379 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 CONSUMPTION OF FRUIT IS 0.313 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 CONSUMPTION OF GRAIN IS 0.000 KG/DAY FOR 0.0 DAYS/YEAR FOR AGE GROUP 2 CONSUMPTION OF GRAIN IS 0.342 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 CONSUMPTION OF GRAIN IS 0.414 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 CONSUMPTION OF GRAIN IS 0.342 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 CONSUMPTION OF MEAT IS 0.000 KG/DAY FOR 0.0 DAYS/YEAR FOR AGE GROUP 2 CONSUMPTION OF MEAT IS 0.112 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 CONSUMPTION OF MEAT IS 0.178 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 CONSUMPTION OF MEAT IS 0.301 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 CONSUMPTION OF POULTRY IS 0.000 KG/DAY FOR 0.0 DAYS/YEAR FOR AGE GROUP 2 CONSUMPTION OF POULTRY IS 0.049 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 CONSUMPTION OF POULTRY IS 0.049 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 CONSUMPTION OF POULTRY IS 0.049 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 CONSUMPTION OF MILK IS 0.904 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 2 CONSUMPTION OF MILK IS 0.900 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 CONSUMPTION OF MILK IS 1.100 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 CONSUMPTION OF MILK IS 0.840 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 CONSUMPTION OF EGGS IS 0.000 KG/DAY FOR 0.0 DAYS/YEAR FOR AGE GROUP 2 CONSUMPTION OF EGGS IS 0.032 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 CONSUMPTION OF EGGS IS 0.032 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 CONSUMPTION OF EGGS IS 0.032 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 CONSUMPTION OF SOIL IS 1.00E+02 MILLIGRAMS/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 2 CONSUMPTION OF SOIL IS 1.00E+02 MILLIGRAMS/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 CONSUMPTION OF SOIL IS 1.00E+02 MILLIGRAMS/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 CONSUMPTION OF SOIL IS 1.00E+02 MILLIGRAMS/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 OUTDOOR INHALATION RATE IS 3.83 M3/DAY FOR 365.0 DAYS/YEAR, WITH A FRACTION OF A DAY OUTDOORS OF 0.250 FOR AGE GROUP 2 OUTDOOR INHALATION RATE IS 10.13 M3/DAY FOR 365.0 DAYS/YEAR, WITH A FRACTION OF A DAY OUTDOORS OF 0.250 FOR AGE GROUP 3 OUTDOOR INHALATION RATE IS 21.90 M3/DAY FOR 365.0 DAYS/YEAR, WITH A FRACTION OF A DAY OUTDOORS OF 0.250 FOR AGE GROUP 4 OUTDOOR INHALATION RATE IS 21.90 M3/DAY FOR 365.0 DAYS/YEAR, WITH A FRACTION OF A DAY OUTDOORS OF 0.250

Design Analyses and Calculation Page 75 of 125 Form Atkins-NS-EN-13-03 R3 FOR AGE GROUP 1 INDOOR INHALATION RATE IS 3.83 M3/DAY FOR 365.0 DAYS/YEAR, WITH A FRACTION OF A DAY INDOORS OF 0.750 FOR AGE GROUP 2 INDOOR INHALATION RATE IS 10.13 M3/DAY FOR 365.0 DAYS/YEAR, WITH A FRACTION OF A DAY INDOORS OF 0.750 FOR AGE GROUP 3 INDOOR INHALATION RATE IS 21.90 M3/DAY FOR 365.0 DAYS/YEAR, WITH A FRACTION OF A DAY INDOORS OF 0.750 FOR AGE GROUP 4 INDOOR INHALATION RATE IS 21.90 M3/DAY FOR 365.0 DAYS/YEAR, WITH A FRACTION OF A DAY INDOORS OF 0.750 ADDITIONAL NOTES:

Napier 2002 S&L 2012-03856 assumed 0 S&L 2012-03856 assumed exit height of 10 m.

Assumed equivalent to exit height of source Assumed 0 m/s consistent with S&L 2012-03856 Set equal to ambient temperature for non-heated release Assume average of average temperatures reported in PSAR Table 19.3.2-20 Reg Guide 1.109 stipulates 1 year duration Reg Guide 1-109 stipulates 1 year exposure Reg Guide 1.109 accumulation time + exposure time Reg Guide 1.109 stipulates 15 year accumulation Duration of release period set at lifetime of operating license per PSAR RG 1.109 Eq C-6: half the radioiodine emissions considered nonelemental.

Average from PSAR Tables 19.3.2-2 and 19.3.2-3 Reg Guide 1.109 Table E-15 Based on assumed values for areal density and surface soil layer thickness Reg Guide 1.109 Table E-15 Time Delay between harvest and ingestion Reg Guide 1.109 Table E-15 Agricultural productivity by unit area Reg Guide 1.109 Table E-15 Period of Growing Season Reg Guide 1.109 Table E-15 Agricultural Productivity Reg Guide 1.109 Table E-15 Time deal ingestion of crops by man Reg Guide 1.109 Table E-15 Ave time from slaughter of meat animal to consumption Reg Guide 1.109 TAble E-15 Attenuation Factor for shielding provided by residential structure Reg Guide 1.109 Table E-5 Infant Intake Reg Guide 1.109 Table E-5 Child Consumption Reg Guide 1.109 Table E-5 Teen Consumption Reg Guide 1.109 Table E-15 Adult Consumption Regulatory Guide 1.109 Table E-3 goat consumption rate 1 EXPOSURE PERIOD(S).

INDIVIDUAL DOSE CALCULATION ONLY, NO POPULATION TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

MAXIMUM POINT = 277 CORRESPONDING TO DIRECTION 13 AND DISTANCE 1 AT LOCATION X= 0.0 KM; Y=

0.0 KM INDIVIDUAL AGE RANGE 0 TO 1 YEARS MAXIMUM EXPOSED INDIVIDUAL LOCATION ORGAN MAX. DOSE (rem )

total body 7.16E-03 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

INDIVIDUAL AGE RANGE 0 TO 1 YEARS INDIVIDUAL EFFECTIVE DOSE BY DISTANCE AND DIRECTION (rem )

241. 402. 805. 1207. 1609. 2414. 3219. 4023. 4828. 5633. 6437. 7242. 8047. 12070. 16093. 24140.

32187. 40234. 48280. 56327. 64374. 72420. 80467.

0. 3.6E-03 1.7E-03 5.4E-04 2.7E-04 1.7E-04 8.8E-05 5.6E-05 3.9E-05 3.0E-05 2.3E-05 1.9E-05 1.6E-05 1.4E-05 7.5E-06 5.0E-06 2.9E-06 1.9E-06 1.4E-06 1.1E-06 9.0E-07 7.6E-07 6.5E-07 5.6E-07
22. 2.0E-03 9.2E-04 3.0E-04 1.5E-04 9.4E-05 4.8E-05 3.1E-05 2.2E-05 1.6E-05 1.3E-05 1.0E-05 8.6E-06 7.3E-06 4.0E-06 2.7E-06 1.5E-06 1.0E-06 7.4E-07 5.7E-07 4.6E-07 3.9E-07 3.3E-07 2.8E-07

Design Analyses and Calculation Page 76 of 125 Form Atkins-NS-EN-13-03 R3

45. 2.4E-03 1.1E-03 3.6E-04 1.8E-04 1.1E-04 5.8E-05 3.6E-05 2.6E-05 1.9E-05 1.5E-05 1.2E-05 1.0E-05 8.7E-06 4.8E-06 3.2E-06 1.8E-06 1.2E-06 8.7E-07 6.8E-07 5.5E-07 4.6E-07 3.9E-07 3.4E-07
68. 2.0E-03 1.3E-03 4.4E-04 2.2E-04 1.4E-04 7.1E-05 4.5E-05 3.2E-05 2.4E-05 1.9E-05 1.5E-05 1.3E-05 1.1E-05 6.1E-06 4.1E-06 2.3E-06 1.6E-06 1.2E-06 9.1E-07 7.4E-07 6.2E-07 5.3E-07 4.6E-07
90. 3.0E-03 2.1E-03 6.9E-04 3.5E-04 2.2E-04 1.1E-04 7.3E-05 5.2E-05 3.9E-05 3.1E-05 2.5E-05 2.1E-05 1.8E-05 1.0E-05 6.9E-06 3.9E-06 2.7E-06 2.0E-06 1.6E-06 1.3E-06 1.1E-06 9.2E-07 8.0E-07 112. 3.3E-03 1.7E-03 5.7E-04 2.9E-04 1.8E-04 9.5E-05 6.1E-05 4.3E-05 3.3E-05 2.6E-05 2.1E-05 1.8E-05 1.5E-05 8.7E-06 5.9E-06 3.4E-06 2.3E-06 1.7E-06 1.4E-06 1.1E-06 9.3E-07 8.0E-07 7.0E-07 135. 3.0E-03 1.5E-03 4.9E-04 2.5E-04 1.6E-04 8.1E-05 5.2E-05 3.7E-05 2.8E-05 2.2E-05 1.8E-05 1.6E-05 1.3E-05 7.5E-06 5.1E-06 2.9E-06 2.0E-06 1.5E-06 1.2E-06 9.7E-07 8.1E-07 6.9E-07 6.1E-07 158. 2.9E-03 1.3E-03 4.3E-04 2.2E-04 1.4E-04 7.1E-05 4.5E-05 3.2E-05 2.4E-05 1.9E-05 1.6E-05 1.3E-05 1.1E-05 6.1E-06 4.1E-06 2.4E-06 1.6E-06 1.2E-06 9.1E-07 7.4E-07 6.2E-07 5.3E-07 4.6E-07 180. 5.0E-03 2.2E-03 7.3E-04 3.7E-04 2.3E-04 1.2E-04 7.5E-05 5.3E-05 4.0E-05 3.1E-05 2.6E-05 2.1E-05 1.8E-05 1.0E-05 6.7E-06 3.8E-06 2.6E-06 1.9E-06 1.5E-06 1.2E-06 1.0E-06 8.6E-07 7.5E-07 202. 4.3E-03 1.9E-03 6.4E-04 3.2E-04 2.0E-04 1.0E-04 6.5E-05 4.6E-05 3.4E-05 2.7E-05 2.2E-05 1.8E-05 1.6E-05 8.6E-06 5.7E-06 3.2E-06 2.2E-06 1.6E-06 1.2E-06 1.0E-06 8.4E-07 7.2E-07 6.3E-07 225. 2.5E-03 1.5E-03 4.9E-04 2.5E-04 1.5E-04 7.9E-05 5.0E-05 3.5E-05 2.6E-05 2.1E-05 1.7E-05 1.4E-05 1.2E-05 6.5E-06 4.3E-06 2.5E-06 1.6E-06 1.2E-06 9.5E-07 7.6E-07 6.4E-07 5.4E-07 4.7E-07 248. 3.3E-03 1.5E-03 4.9E-04 2.5E-04 1.5E-04 8.0E-05 5.1E-05 3.6E-05 2.7E-05 2.1E-05 1.8E-05 1.5E-05 1.3E-05 6.9E-06 4.6E-06 2.6E-06 1.8E-06 1.3E-06 1.0E-06 8.4E-07 7.0E-07 6.0E-07 5.2E-07 270. 7.2E-03 3.1E-03 1.0E-03 5.2E-04 3.2E-04 1.7E-04 1.1E-04 7.6E-05 5.8E-05 4.6E-05 3.7E-05 3.2E-05 2.7E-05 1.5E-05 1.0E-05 5.8E-06 4.0E-06 3.0E-06 2.3E-06 1.9E-06 1.6E-06 1.4E-06 1.2E-06 292. 4.6E-03 2.1E-03 7.0E-04 3.5E-04 2.2E-04 1.1E-04 7.3E-05 5.2E-05 3.9E-05 3.1E-05 2.5E-05 2.1E-05 1.8E-05 1.0E-05 6.8E-06 3.9E-06 2.7E-06 2.0E-06 1.5E-06 1.3E-06 1.1E-06 9.1E-07 8.0E-07 315. 4.1E-03 1.9E-03 6.3E-04 3.2E-04 2.0E-04 1.0E-04 6.5E-05 4.6E-05 3.4E-05 2.7E-05 2.2E-05 1.9E-05 1.6E-05 8.7E-06 5.8E-06 3.3E-06 2.3E-06 1.7E-06 1.3E-06 1.1E-06 8.9E-07 7.6E-07 6.6E-07 338. 3.2E-03 1.5E-03 4.8E-04 2.4E-04 1.5E-04 7.8E-05 4.9E-05 3.5E-05 2.6E-05 2.1E-05 1.7E-05 1.4E-05 1.2E-05 6.6E-06 4.4E-06 2.5E-06 1.7E-06 1.2E-06 9.7E-07 7.9E-07 6.6E-07 5.6E-07 4.9E-07 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

MAXIMUM LOCATION = 277 INDIVIDUAL EFFECTIVE DOSE AND RISK BY NUCLIDE NUCLIDE DOSE (rem ) CANCER INCIDENCE CANCER FATALITIES INDIVIDUAL AGE RANGE 0 TO 1 YEARS AR41 2.61E-04 0.00E+00 0.00E+00 I131 2.42E-03 0.00E+00 0.00E+00 KR85 3.74E-06 0.00E+00 0.00E+00 XE131m 5.66E-05 0.00E+00 0.00E+00 XE133 4.41E-03 0.00E+00 0.00E+00 XE133m 1.47E-07 0.00E+00 0.00E+00 EFFECTIVE DOSE (rem )BY RELEASE CATEGORY AT MAXIMUM INDIVIDUAL LOCATION:

TRITIUM (PLUS OBT) : 0.00E+00 CARBON-14 : 0.00E+00 NOBLE GASES : 4.73E-03 IODINE RADIONUCLIDES: 2.42E-03 PARTICULATE NUCLIDES: 0.00E+00 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

INDIVIDUAL AGE RANGE 0 TO 1 YEARS MAXIMUM LOCATION = 277 INDIVIDUAL EFFECTIVE DOSE AND RISK BY EXPOSURE PATHWAY PATHWAY ROUTE DOSE (rem ) CANCER INCIDENCE CANCER FATALITIES Air external 4.74E-03 0.00E+00 0.00E+00 Air inhalation 2.46E-05 0.00E+00 0.00E+00 Eggs ingestion 0.00E+00 0.00E+00 0.00E+00 Fruit ingestion 0.00E+00 0.00E+00 0.00E+00 Grain ingestion 0.00E+00 0.00E+00 0.00E+00 Ground external 2.12E-05 0.00E+00 0.00E+00 Indoor air inhalation 7.39E-05 0.00E+00 0.00E+00

Design Analyses and Calculation Page 77 of 125 Form Atkins-NS-EN-13-03 R3 Leafy vegetables ingestion 0.00E+00 0.00E+00 0.00E+00 Meat ingestion 0.00E+00 0.00E+00 0.00E+00 Milk ingestion 2.30E-03 0.00E+00 0.00E+00 Poultry ingestion 0.00E+00 0.00E+00 0.00E+00 Root vegetables ingestion 0.00E+00 0.00E+00 0.00E+00 Soil ingestion 9.94E-09 0.00E+00 0.00E+00 Soil inhalation 0.00E+00 0.00E+00 0.00E+00 INDIVIDUAL EFFECTIVE DOSE AND RISK BY PATHWAY BY RADIONUCLIDE INDIVIDUAL DOSE FOR PATHWAY: Air external DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 2.61E-04 5.51%

I131 4.54E-06 0.10%

KR85 3.74E-06 0.08%

XE131m 5.66E-05 1.20%

XE133 4.41E-03 93.12%

XE133m 1.47E-07 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Air inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 2.46E-05 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Eggs ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Fruit ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Grain ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Ground external DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 2.12E-05 99.94%

KR85 0.00E+00 0.00%

XE131m 1.18E-08 0.06%

Design Analyses and Calculation Page 78 of 125 Form Atkins-NS-EN-13-03 R3 XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Indoor air inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 7.39E-05 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Leafy vegetables ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Meat ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Milk ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 2.30E-03 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Poultry ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Root vegetables ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Soil ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 9.94E-09 100.00%

Design Analyses and Calculation Page 79 of 125 Form Atkins-NS-EN-13-03 R3 KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Soil inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

1 EXPOSURE PERIOD(S).

INDIVIDUAL DOSE CALCULATION ONLY, NO POPULATION TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

MAXIMUM POINT = 277 CORRESPONDING TO DIRECTION 13 AND DISTANCE 1 AT LOCATION X= 0.0 KM; Y=

0.0 KM INDIVIDUAL AGE RANGE 1 TO 11 YEARS MAXIMUM EXPOSED INDIVIDUAL LOCATION ORGAN MAX. DOSE (rem )

total body 7.87E-03 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

INDIVIDUAL AGE RANGE 1 TO 11 YEARS INDIVIDUAL EFFECTIVE DOSE BY DISTANCE AND DIRECTION (rem )

241. 402. 805. 1207. 1609. 2414. 3219. 4023. 4828. 5633. 6437. 7242. 8047. 12070. 16093. 24140.

32187. 40234. 48280. 56327. 64374. 72420. 80467.

0. 3.9E-03 1.8E-03 6.0E-04 3.0E-04 1.9E-04 9.7E-05 6.2E-05 4.3E-05 3.3E-05 2.6E-05 2.1E-05 1.7E-05 1.5E-05 8.2E-06 5.4E-06 3.1E-06 2.1E-06 1.5E-06 1.2E-06 9.6E-07 8.0E-07 6.9E-07 6.0E-07
22. 2.2E-03 1.0E-03 3.4E-04 1.7E-04 1.0E-04 5.4E-05 3.4E-05 2.4E-05 1.8E-05 1.4E-05 1.1E-05 9.4E-06 8.1E-06 4.4E-06 2.9E-06 1.6E-06 1.1E-06 7.9E-07 6.1E-07 4.9E-07 4.1E-07 3.5E-07 3.0E-07
45. 2.6E-03 1.2E-03 4.0E-04 2.0E-04 1.2E-04 6.4E-05 4.0E-05 2.8E-05 2.1E-05 1.7E-05 1.3E-05 1.1E-05 9.5E-06 5.2E-06 3.4E-06 1.9E-06 1.3E-06 9.4E-07 7.3E-07 5.9E-07 4.9E-07 4.2E-07 3.6E-07
68. 2.2E-03 1.5E-03 4.8E-04 2.4E-04 1.5E-04 7.8E-05 5.0E-05 3.5E-05 2.6E-05 2.1E-05 1.7E-05 1.4E-05 1.2E-05 6.6E-06 4.4E-06 2.5E-06 1.7E-06 1.2E-06 9.6E-07 7.8E-07 6.5E-07 5.6E-07 4.8E-07
90. 3.3E-03 2.3E-03 7.6E-04 3.9E-04 2.4E-04 1.3E-04 7.9E-05 5.6E-05 4.2E-05 3.4E-05 2.8E-05 2.3E-05 2.0E-05 1.1E-05 7.4E-06 4.2E-06 2.8E-06 2.1E-06 1.7E-06 1.4E-06 1.1E-06 9.7E-07 8.4E-07 112. 3.6E-03 1.9E-03 6.3E-04 3.2E-04 2.0E-04 1.0E-04 6.6E-05 4.7E-05 3.5E-05 2.8E-05 2.3E-05 1.9E-05 1.7E-05 9.3E-06 6.3E-06 3.6E-06 2.4E-06 1.8E-06 1.4E-06 1.2E-06 9.8E-07 8.4E-07 7.4E-07 135. 3.3E-03 1.6E-03 5.4E-04 2.7E-04 1.7E-04 8.9E-05 5.7E-05 4.0E-05 3.1E-05 2.4E-05 2.0E-05 1.7E-05 1.4E-05 8.0E-06 5.4E-06 3.1E-06 2.1E-06 1.6E-06 1.2E-06 1.0E-06 8.5E-07 7.3E-07 6.4E-07 158. 3.2E-03 1.5E-03 4.8E-04 2.4E-04 1.5E-04 7.8E-05 5.0E-05 3.5E-05 2.6E-05 2.1E-05 1.7E-05 1.4E-05 1.2E-05 6.6E-06 4.4E-06 2.5E-06 1.7E-06 1.2E-06 9.7E-07 7.9E-07 6.6E-07 5.6E-07 4.9E-07 180. 5.6E-03 2.5E-03 8.1E-04 4.1E-04 2.6E-04 1.3E-04 8.3E-05 5.8E-05 4.4E-05 3.5E-05 2.8E-05 2.3E-05 2.0E-05 1.1E-05 7.3E-06 4.1E-06 2.8E-06 2.0E-06 1.6E-06 1.3E-06 1.1E-06 9.1E-07 7.9E-07 202. 4.8E-03 2.2E-03 7.1E-04 3.6E-04 2.2E-04 1.1E-04 7.2E-05 5.0E-05 3.8E-05 3.0E-05 2.4E-05 2.0E-05 1.7E-05 9.3E-06 6.2E-06 3.5E-06 2.3E-06 1.7E-06 1.3E-06 1.1E-06 9.0E-07 7.7E-07 6.7E-07 225. 2.8E-03 1.7E-03 5.5E-04 2.8E-04 1.7E-04 8.9E-05 5.6E-05 3.9E-05 2.9E-05 2.3E-05 1.9E-05 1.5E-05 1.3E-05 7.1E-06 4.7E-06 2.7E-06 1.8E-06 1.3E-06 1.0E-06 8.1E-07 6.8E-07 5.8E-07 5.0E-07 248. 3.6E-03 1.7E-03 5.5E-04 2.8E-04 1.7E-04 8.9E-05 5.6E-05 4.0E-05 3.0E-05 2.3E-05 1.9E-05 1.6E-05 1.4E-05 7.5E-06 5.0E-06 2.8E-06 1.9E-06 1.4E-06 1.1E-06 8.9E-07 7.5E-07 6.4E-07 5.5E-07 270. 7.9E-03 3.4E-03 1.1E-03 5.7E-04 3.6E-04 1.9E-04 1.2E-04 8.3E-05 6.3E-05 5.0E-05 4.1E-05 3.4E-05 2.9E-05 1.6E-05 1.1E-05 6.2E-06 4.2E-06 3.1E-06 2.5E-06 2.0E-06 1.7E-06 1.4E-06 1.3E-06 292. 5.1E-03 2.3E-03 7.7E-04 3.9E-04 2.4E-04 1.3E-04 8.0E-05 5.6E-05 4.3E-05 3.4E-05 2.8E-05 2.3E-05 2.0E-05 1.1E-05 7.3E-06 4.2E-06 2.8E-06 2.1E-06 1.6E-06 1.3E-06 1.1E-06 9.6E-07 8.4E-07

Design Analyses and Calculation Page 80 of 125 Form Atkins-NS-EN-13-03 R3 315. 4.6E-03 2.1E-03 7.0E-04 3.5E-04 2.2E-04 1.1E-04 7.1E-05 5.0E-05 3.8E-05 3.0E-05 2.4E-05 2.0E-05 1.7E-05 9.5E-06 6.3E-06 3.6E-06 2.4E-06 1.8E-06 1.4E-06 1.1E-06 9.4E-07 8.1E-07 7.0E-07 338. 3.5E-03 1.6E-03 5.3E-04 2.7E-04 1.7E-04 8.6E-05 5.4E-05 3.8E-05 2.9E-05 2.3E-05 1.8E-05 1.5E-05 1.3E-05 7.2E-06 4.8E-06 2.7E-06 1.8E-06 1.3E-06 1.0E-06 8.4E-07 7.0E-07 6.0E-07 5.2E-07 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

MAXIMUM LOCATION = 277 INDIVIDUAL EFFECTIVE DOSE AND RISK BY NUCLIDE NUCLIDE DOSE (rem ) CANCER INCIDENCE CANCER FATALITIES INDIVIDUAL AGE RANGE 1 TO 11 YEARS AR41 2.61E-04 0.00E+00 0.00E+00 I131 3.14E-03 0.00E+00 0.00E+00 KR85 3.74E-06 0.00E+00 0.00E+00 XE131m 5.66E-05 0.00E+00 0.00E+00 XE133 4.41E-03 0.00E+00 0.00E+00 XE133m 1.47E-07 0.00E+00 0.00E+00 EFFECTIVE DOSE (rem )BY RELEASE CATEGORY AT MAXIMUM INDIVIDUAL LOCATION:

TRITIUM (PLUS OBT) : 0.00E+00 CARBON-14 : 0.00E+00 NOBLE GASES : 4.73E-03 IODINE RADIONUCLIDES: 3.14E-03 PARTICULATE NUCLIDES: 0.00E+00 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

INDIVIDUAL AGE RANGE 1 TO 11 YEARS MAXIMUM LOCATION = 277 INDIVIDUAL EFFECTIVE DOSE AND RISK BY EXPOSURE PATHWAY PATHWAY ROUTE DOSE (rem ) CANCER INCIDENCE CANCER FATALITIES Air external 4.74E-03 0.00E+00 0.00E+00 Air inhalation 6.51E-05 0.00E+00 0.00E+00 Eggs ingestion 1.28E-08 0.00E+00 0.00E+00 Fruit ingestion 9.22E-07 0.00E+00 0.00E+00 Grain ingestion 1.89E-06 0.00E+00 0.00E+00 Ground external 2.12E-05 0.00E+00 0.00E+00 Indoor air inhalation 1.96E-04 0.00E+00 0.00E+00 Leafy vegetables ingestion 5.08E-04 0.00E+00 0.00E+00 Meat ingestion 4.61E-05 0.00E+00 0.00E+00 Milk ingestion 2.29E-03 0.00E+00 0.00E+00 Poultry ingestion 2.23E-10 0.00E+00 0.00E+00 Root vegetables ingestion 3.40E-06 0.00E+00 0.00E+00 Soil ingestion 9.94E-09 0.00E+00 0.00E+00 Soil inhalation 0.00E+00 0.00E+00 0.00E+00 INDIVIDUAL EFFECTIVE DOSE AND RISK BY PATHWAY BY RADIONUCLIDE INDIVIDUAL DOSE FOR PATHWAY: Air external DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 2.61E-04 5.51%

I131 4.54E-06 0.10%

KR85 3.74E-06 0.08%

XE131m 5.66E-05 1.20%

XE133 4.41E-03 93.12%

XE133m 1.47E-07 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Air inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 6.51E-05 100.00%

KR85 0.00E+00 0.00%

Design Analyses and Calculation Page 81 of 125 Form Atkins-NS-EN-13-03 R3 XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Eggs ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.28E-08 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Fruit ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 9.22E-07 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Grain ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.89E-06 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Ground external DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 2.12E-05 99.94%

KR85 0.00E+00 0.00%

XE131m 1.18E-08 0.06%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Indoor air inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.96E-04 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Leafy vegetables ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 5.08E-04 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Meat ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

Design Analyses and Calculation Page 82 of 125 Form Atkins-NS-EN-13-03 R3 I131 4.61E-05 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Milk ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 2.29E-03 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Poultry ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 2.23E-10 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Root vegetables ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 3.40E-06 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Soil ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 9.94E-09 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Soil inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

1 EXPOSURE PERIOD(S).

INDIVIDUAL DOSE CALCULATION ONLY, NO POPULATION TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

MAXIMUM POINT = 277 CORRESPONDING TO DIRECTION 13 AND DISTANCE 1 AT LOCATION X= 0.0 KM; Y=

0.0 KM INDIVIDUAL AGE RANGE 11 TO 17 YEARS MAXIMUM EXPOSED INDIVIDUAL LOCATION

Design Analyses and Calculation Page 83 of 125 Form Atkins-NS-EN-13-03 R3 ORGAN MAX. DOSE (rem )

total body 9.01E-03 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

INDIVIDUAL AGE RANGE 11 TO 17 YEARS INDIVIDUAL EFFECTIVE DOSE BY DISTANCE AND DIRECTION (rem )

241. 402. 805. 1207. 1609. 2414. 3219. 4023. 4828. 5633. 6437. 7242. 8047. 12070. 16093. 24140.

32187. 40234. 48280. 56327. 64374. 72420. 80467.

0. 4.5E-03 2.1E-03 7.0E-04 3.5E-04 2.2E-04 1.1E-04 7.1E-05 5.0E-05 3.7E-05 2.9E-05 2.4E-05 2.0E-05 1.7E-05 9.2E-06 6.1E-06 3.4E-06 2.3E-06 1.7E-06 1.3E-06 1.1E-06 8.8E-07 7.5E-07 6.5E-07
22. 2.5E-03 1.2E-03 3.9E-04 2.0E-04 1.2E-04 6.3E-05 3.9E-05 2.8E-05 2.1E-05 1.6E-05 1.3E-05 1.1E-05 9.2E-06 5.0E-06 3.3E-06 1.8E-06 1.2E-06 8.8E-07 6.8E-07 5.5E-07 4.5E-07 3.8E-07 3.3E-07
45. 3.1E-03 1.4E-03 4.6E-04 2.4E-04 1.5E-04 7.5E-05 4.7E-05 3.3E-05 2.4E-05 1.9E-05 1.5E-05 1.3E-05 1.1E-05 5.9E-06 3.9E-06 2.2E-06 1.4E-06 1.0E-06 8.1E-07 6.5E-07 5.4E-07 4.6E-07 3.9E-07
68. 2.5E-03 1.7E-03 5.6E-04 2.8E-04 1.8E-04 9.0E-05 5.7E-05 4.0E-05 3.0E-05 2.4E-05 1.9E-05 1.6E-05 1.4E-05 7.4E-06 4.9E-06 2.8E-06 1.9E-06 1.4E-06 1.1E-06 8.6E-07 7.1E-07 6.1E-07 5.3E-07
90. 3.8E-03 2.6E-03 8.7E-04 4.4E-04 2.8E-04 1.4E-04 9.0E-05 6.4E-05 4.8E-05 3.8E-05 3.1E-05 2.6E-05 2.2E-05 1.2E-05 8.2E-06 4.7E-06 3.1E-06 2.3E-06 1.8E-06 1.5E-06 1.2E-06 1.1E-06 9.1E-07 112. 4.1E-03 2.1E-03 7.1E-04 3.6E-04 2.3E-04 1.2E-04 7.4E-05 5.3E-05 4.0E-05 3.2E-05 2.6E-05 2.2E-05 1.9E-05 1.0E-05 6.9E-06 4.0E-06 2.7E-06 2.0E-06 1.6E-06 1.3E-06 1.1E-06 9.1E-07 8.0E-07 135. 3.7E-03 1.8E-03 6.1E-04 3.1E-04 1.9E-04 1.0E-04 6.4E-05 4.5E-05 3.4E-05 2.7E-05 2.2E-05 1.9E-05 1.6E-05 8.9E-06 6.0E-06 3.4E-06 2.3E-06 1.7E-06 1.4E-06 1.1E-06 9.2E-07 7.9E-07 6.9E-07 158. 3.6E-03 1.7E-03 5.6E-04 2.8E-04 1.8E-04 9.0E-05 5.7E-05 4.0E-05 3.0E-05 2.4E-05 1.9E-05 1.6E-05 1.4E-05 7.5E-06 5.0E-06 2.8E-06 1.9E-06 1.4E-06 1.1E-06 8.7E-07 7.2E-07 6.2E-07 5.4E-07 180. 6.4E-03 2.9E-03 9.5E-04 4.8E-04 3.0E-04 1.5E-04 9.6E-05 6.7E-05 5.0E-05 4.0E-05 3.2E-05 2.7E-05 2.3E-05 1.2E-05 8.2E-06 4.6E-06 3.1E-06 2.3E-06 1.8E-06 1.4E-06 1.2E-06 1.0E-06 8.7E-07 202. 5.5E-03 2.5E-03 8.3E-04 4.2E-04 2.6E-04 1.3E-04 8.3E-05 5.8E-05 4.4E-05 3.4E-05 2.8E-05 2.3E-05 2.0E-05 1.1E-05 7.0E-06 3.9E-06 2.6E-06 1.9E-06 1.5E-06 1.2E-06 9.9E-07 8.4E-07 7.3E-07 225. 3.2E-03 2.0E-03 6.5E-04 3.3E-04 2.0E-04 1.0E-04 6.5E-05 4.5E-05 3.4E-05 2.6E-05 2.1E-05 1.8E-05 1.5E-05 8.1E-06 5.4E-06 3.0E-06 2.0E-06 1.4E-06 1.1E-06 9.0E-07 7.5E-07 6.4E-07 5.5E-07 248. 4.2E-03 1.9E-03 6.3E-04 3.2E-04 2.0E-04 1.0E-04 6.5E-05 4.5E-05 3.4E-05 2.7E-05 2.2E-05 1.8E-05 1.5E-05 8.5E-06 5.6E-06 3.2E-06 2.1E-06 1.6E-06 1.2E-06 9.8E-07 8.2E-07 7.0E-07 6.0E-07 270. 9.0E-03 3.9E-03 1.3E-03 6.6E-04 4.1E-04 2.1E-04 1.3E-04 9.5E-05 7.1E-05 5.6E-05 4.6E-05 3.8E-05 3.3E-05 1.8E-05 1.2E-05 6.9E-06 4.6E-06 3.4E-06 2.7E-06 2.2E-06 1.8E-06 1.6E-06 1.4E-06 292. 5.8E-03 2.7E-03 8.8E-04 4.5E-04 2.8E-04 1.4E-04 9.1E-05 6.4E-05 4.8E-05 3.8E-05 3.1E-05 2.6E-05 2.2E-05 1.2E-05 8.2E-06 4.6E-06 3.1E-06 2.3E-06 1.8E-06 1.5E-06 1.2E-06 1.0E-06 9.2E-07 315. 5.3E-03 2.4E-03 8.1E-04 4.1E-04 2.5E-04 1.3E-04 8.2E-05 5.8E-05 4.3E-05 3.4E-05 2.8E-05 2.3E-05 2.0E-05 1.1E-05 7.1E-06 4.0E-06 2.7E-06 2.0E-06 1.5E-06 1.2E-06 1.0E-06 8.8E-07 7.7E-07 338. 4.1E-03 1.9E-03 6.2E-04 3.1E-04 1.9E-04 1.0E-04 6.3E-05 4.4E-05 3.3E-05 2.6E-05 2.1E-05 1.8E-05 1.5E-05 8.1E-06 5.4E-06 3.0E-06 2.0E-06 1.5E-06 1.1E-06 9.2E-07 7.7E-07 6.5E-07 5.7E-07 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

MAXIMUM LOCATION = 277 INDIVIDUAL EFFECTIVE DOSE AND RISK BY NUCLIDE NUCLIDE DOSE (rem ) CANCER INCIDENCE CANCER FATALITIES INDIVIDUAL AGE RANGE 11 TO 17 YEARS AR41 2.61E-04 0.00E+00 0.00E+00 I131 4.28E-03 0.00E+00 0.00E+00 KR85 3.74E-06 0.00E+00 0.00E+00 XE131m 5.66E-05 0.00E+00 0.00E+00 XE133 4.41E-03 0.00E+00 0.00E+00 XE133m 1.47E-07 0.00E+00 0.00E+00 EFFECTIVE DOSE (rem )BY RELEASE CATEGORY AT MAXIMUM INDIVIDUAL LOCATION:

TRITIUM (PLUS OBT) : 0.00E+00 CARBON-14 : 0.00E+00 NOBLE GASES : 4.73E-03 IODINE RADIONUCLIDES: 4.28E-03 PARTICULATE NUCLIDES: 0.00E+00

Design Analyses and Calculation Page 84 of 125 Form Atkins-NS-EN-13-03 R3 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

INDIVIDUAL AGE RANGE 11 TO 17 YEARS MAXIMUM LOCATION = 277 INDIVIDUAL EFFECTIVE DOSE AND RISK BY EXPOSURE PATHWAY PATHWAY ROUTE DOSE (rem ) CANCER INCIDENCE CANCER FATALITIES Air external 4.74E-03 0.00E+00 0.00E+00 Air inhalation 1.40E-04 0.00E+00 0.00E+00 Eggs ingestion 1.28E-08 0.00E+00 0.00E+00 Fruit ingestion 1.12E-06 0.00E+00 0.00E+00 Grain ingestion 2.29E-06 0.00E+00 0.00E+00 Ground external 2.12E-05 0.00E+00 0.00E+00 Indoor air inhalation 4.22E-04 0.00E+00 0.00E+00 Leafy vegetables ingestion 8.22E-04 0.00E+00 0.00E+00 Meat ingestion 7.32E-05 0.00E+00 0.00E+00 Milk ingestion 2.79E-03 0.00E+00 0.00E+00 Poultry ingestion 2.23E-10 0.00E+00 0.00E+00 Root vegetables ingestion 4.12E-06 0.00E+00 0.00E+00 Soil ingestion 9.94E-09 0.00E+00 0.00E+00 Soil inhalation 0.00E+00 0.00E+00 0.00E+00 INDIVIDUAL EFFECTIVE DOSE AND RISK BY PATHWAY BY RADIONUCLIDE INDIVIDUAL DOSE FOR PATHWAY: Air external DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 2.61E-04 5.51%

I131 4.54E-06 0.10%

KR85 3.74E-06 0.08%

XE131m 5.66E-05 1.20%

XE133 4.41E-03 93.12%

XE133m 1.47E-07 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Air inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.40E-04 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Eggs ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.28E-08 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Fruit ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.12E-06 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Grain ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

Design Analyses and Calculation Page 85 of 125 Form Atkins-NS-EN-13-03 R3 I131 2.29E-06 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Ground external DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 2.12E-05 99.94%

KR85 0.00E+00 0.00%

XE131m 1.18E-08 0.06%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Indoor air inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 4.22E-04 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Leafy vegetables ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 8.22E-04 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Meat ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 7.32E-05 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Milk ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 2.79E-03 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Poultry ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 2.23E-10 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Root vegetables ingestion

Design Analyses and Calculation Page 86 of 125 Form Atkins-NS-EN-13-03 R3 DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 4.12E-06 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Soil ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 9.94E-09 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Soil inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

1 EXPOSURE PERIOD(S).

INDIVIDUAL DOSE CALCULATION ONLY, NO POPULATION TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

MAXIMUM POINT = 277 CORRESPONDING TO DIRECTION 13 AND DISTANCE 1 AT LOCATION X= 0.0 KM; Y=

0.0 KM INDIVIDUAL AGE RANGE 17 TO 70 YEARS MAXIMUM EXPOSED INDIVIDUAL LOCATION ORGAN MAX. DOSE (rem )

total body 8.64E-03 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

INDIVIDUAL AGE RANGE 17 TO 70 YEARS INDIVIDUAL EFFECTIVE DOSE BY DISTANCE AND DIRECTION (rem )

241. 402. 805. 1207. 1609. 2414. 3219. 4023. 4828. 5633. 6437. 7242. 8047. 12070. 16093. 24140.

32187. 40234. 48280. 56327. 64374. 72420. 80467.

0. 4.3E-03 2.0E-03 6.6E-04 3.4E-04 2.1E-04 1.1E-04 6.8E-05 4.8E-05 3.6E-05 2.8E-05 2.3E-05 1.9E-05 1.6E-05 8.9E-06 5.9E-06 3.3E-06 2.2E-06 1.6E-06 1.3E-06 1.0E-06 8.6E-07 7.4E-07 6.4E-07
22. 2.4E-03 1.1E-03 3.7E-04 1.9E-04 1.2E-04 6.0E-05 3.8E-05 2.6E-05 2.0E-05 1.5E-05 1.2E-05 1.0E-05 8.8E-06 4.8E-06 3.2E-06 1.8E-06 1.2E-06 8.6E-07 6.6E-07 5.3E-07 4.4E-07 3.8E-07 3.2E-07
45. 2.9E-03 1.4E-03 4.4E-04 2.2E-04 1.4E-04 7.1E-05 4.5E-05 3.1E-05 2.3E-05 1.8E-05 1.5E-05 1.2E-05 1.0E-05 5.7E-06 3.7E-06 2.1E-06 1.4E-06 1.0E-06 7.9E-07 6.3E-07 5.3E-07 4.5E-07 3.9E-07
68. 2.4E-03 1.6E-03 5.3E-04 2.7E-04 1.7E-04 8.6E-05 5.5E-05 3.8E-05 2.9E-05 2.3E-05 1.9E-05 1.5E-05 1.3E-05 7.2E-06 4.8E-06 2.7E-06 1.8E-06 1.3E-06 1.0E-06 8.4E-07 7.0E-07 6.0E-07 5.2E-07
90. 3.7E-03 2.5E-03 8.4E-04 4.2E-04 2.6E-04 1.4E-04 8.7E-05 6.1E-05 4.6E-05 3.7E-05 3.0E-05 2.5E-05 2.1E-05 1.2E-05 8.0E-06 4.5E-06 3.1E-06 2.3E-06 1.8E-06 1.4E-06 1.2E-06 1.0E-06 9.0E-07 112. 4.0E-03 2.1E-03 6.9E-04 3.5E-04 2.2E-04 1.1E-04 7.2E-05 5.1E-05 3.9E-05 3.1E-05 2.5E-05 2.1E-05 1.8E-05 1.0E-05 6.8E-06 3.9E-06 2.6E-06 2.0E-06 1.5E-06 1.3E-06 1.1E-06 9.0E-07 7.9E-07 135. 3.6E-03 1.8E-03 5.9E-04 3.0E-04 1.9E-04 9.7E-05 6.2E-05 4.4E-05 3.3E-05 2.6E-05 2.2E-05 1.8E-05 1.6E-05 8.7E-06 5.8E-06 3.4E-06 2.3E-06 1.7E-06 1.3E-06 1.1E-06 9.1E-07 7.8E-07 6.8E-07 158. 3.5E-03 1.6E-03 5.3E-04 2.7E-04 1.7E-04 8.6E-05 5.5E-05 3.8E-05 2.9E-05 2.3E-05 1.9E-05 1.5E-05 1.3E-05 7.2E-06 4.8E-06 2.7E-06 1.8E-06 1.3E-06 1.0E-06 8.5E-07 7.1E-07 6.1E-07 5.3E-07

Design Analyses and Calculation Page 87 of 125 Form Atkins-NS-EN-13-03 R3 180. 6.1E-03 2.7E-03 9.0E-04 4.5E-04 2.8E-04 1.5E-04 9.2E-05 6.4E-05 4.8E-05 3.8E-05 3.1E-05 2.6E-05 2.2E-05 1.2E-05 7.9E-06 4.5E-06 3.0E-06 2.2E-06 1.7E-06 1.4E-06 1.2E-06 9.8E-07 8.5E-07 202. 5.3E-03 2.4E-03 7.9E-04 4.0E-04 2.5E-04 1.3E-04 7.9E-05 5.6E-05 4.2E-05 3.3E-05 2.7E-05 2.2E-05 1.9E-05 1.0E-05 6.8E-06 3.8E-06 2.5E-06 1.9E-06 1.4E-06 1.2E-06 9.7E-07 8.3E-07 7.2E-07 225. 3.1E-03 1.9E-03 6.1E-04 3.1E-04 1.9E-04 9.8E-05 6.2E-05 4.3E-05 3.2E-05 2.5E-05 2.0E-05 1.7E-05 1.4E-05 7.8E-06 5.2E-06 2.9E-06 1.9E-06 1.4E-06 1.1E-06 8.8E-07 7.3E-07 6.2E-07 5.4E-07 248. 4.0E-03 1.8E-03 6.0E-04 3.0E-04 1.9E-04 9.8E-05 6.2E-05 4.3E-05 3.3E-05 2.6E-05 2.1E-05 1.8E-05 1.5E-05 8.2E-06 5.5E-06 3.1E-06 2.1E-06 1.5E-06 1.2E-06 9.6E-07 8.0E-07 6.8E-07 5.9E-07 270. 8.6E-03 3.7E-03 1.2E-03 6.3E-04 3.9E-04 2.0E-04 1.3E-04 9.1E-05 6.9E-05 5.4E-05 4.4E-05 3.7E-05 3.2E-05 1.8E-05 1.2E-05 6.7E-06 4.6E-06 3.4E-06 2.6E-06 2.2E-06 1.8E-06 1.5E-06 1.3E-06 292. 5.6E-03 2.6E-03 8.4E-04 4.3E-04 2.7E-04 1.4E-04 8.7E-05 6.2E-05 4.7E-05 3.7E-05 3.0E-05 2.5E-05 2.1E-05 1.2E-05 7.9E-06 4.5E-06 3.1E-06 2.3E-06 1.8E-06 1.4E-06 1.2E-06 1.0E-06 9.0E-07 315. 5.0E-03 2.3E-03 7.7E-04 3.9E-04 2.4E-04 1.2E-04 7.9E-05 5.5E-05 4.2E-05 3.3E-05 2.7E-05 2.2E-05 1.9E-05 1.0E-05 6.9E-06 3.9E-06 2.6E-06 1.9E-06 1.5E-06 1.2E-06 1.0E-06 8.7E-07 7.5E-07 338. 3.9E-03 1.8E-03 5.9E-04 3.0E-04 1.8E-04 9.5E-05 6.0E-05 4.2E-05 3.2E-05 2.5E-05 2.0E-05 1.7E-05 1.4E-05 7.8E-06 5.2E-06 2.9E-06 2.0E-06 1.4E-06 1.1E-06 9.0E-07 7.6E-07 6.4E-07 5.6E-07 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

MAXIMUM LOCATION = 277 INDIVIDUAL EFFECTIVE DOSE AND RISK BY NUCLIDE NUCLIDE DOSE (rem ) CANCER INCIDENCE CANCER FATALITIES INDIVIDUAL AGE RANGE 17 TO 70 YEARS AR41 2.61E-04 0.00E+00 0.00E+00 I131 3.91E-03 0.00E+00 0.00E+00 KR85 3.74E-06 0.00E+00 0.00E+00 XE131m 5.66E-05 0.00E+00 0.00E+00 XE133 4.41E-03 0.00E+00 0.00E+00 XE133m 1.47E-07 0.00E+00 0.00E+00 EFFECTIVE DOSE (rem )BY RELEASE CATEGORY AT MAXIMUM INDIVIDUAL LOCATION:

TRITIUM (PLUS OBT) : 0.00E+00 CARBON-14 : 0.00E+00 NOBLE GASES : 4.73E-03 IODINE RADIONUCLIDES: 3.91E-03 PARTICULATE NUCLIDES: 0.00E+00 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

INDIVIDUAL AGE RANGE 17 TO 70 YEARS MAXIMUM LOCATION = 277 INDIVIDUAL EFFECTIVE DOSE AND RISK BY EXPOSURE PATHWAY PATHWAY ROUTE DOSE (rem ) CANCER INCIDENCE CANCER FATALITIES Air external 4.74E-03 0.00E+00 0.00E+00 Air inhalation 1.40E-04 0.00E+00 0.00E+00 Eggs ingestion 1.28E-08 0.00E+00 0.00E+00 Fruit ingestion 9.22E-07 0.00E+00 0.00E+00 Grain ingestion 1.89E-06 0.00E+00 0.00E+00 Ground external 2.12E-05 0.00E+00 0.00E+00 Indoor air inhalation 4.22E-04 0.00E+00 0.00E+00 Leafy vegetables ingestion 1.06E-03 0.00E+00 0.00E+00 Meat ingestion 1.24E-04 0.00E+00 0.00E+00 Milk ingestion 2.13E-03 0.00E+00 0.00E+00 Poultry ingestion 2.23E-10 0.00E+00 0.00E+00 Root vegetables ingestion 3.40E-06 0.00E+00 0.00E+00 Soil ingestion 9.94E-09 0.00E+00 0.00E+00 Soil inhalation 0.00E+00 0.00E+00 0.00E+00 INDIVIDUAL EFFECTIVE DOSE AND RISK BY PATHWAY BY RADIONUCLIDE INDIVIDUAL DOSE FOR PATHWAY: Air external DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION

Design Analyses and Calculation Page 88 of 125 Form Atkins-NS-EN-13-03 R3 AR41 2.61E-04 5.51%

I131 4.54E-06 0.10%

KR85 3.74E-06 0.08%

XE131m 5.66E-05 1.20%

XE133 4.41E-03 93.12%

XE133m 1.47E-07 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Air inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.40E-04 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Eggs ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.28E-08 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Fruit ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 9.22E-07 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Grain ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.89E-06 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Ground external DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 2.12E-05 99.94%

KR85 0.00E+00 0.00%

XE131m 1.18E-08 0.06%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Indoor air inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 4.22E-04 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

Design Analyses and Calculation Page 89 of 125 Form Atkins-NS-EN-13-03 R3 INDIVIDUAL DOSE FOR PATHWAY: Leafy vegetables ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.06E-03 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Meat ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.24E-04 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Milk ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 2.13E-03 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Poultry ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 2.23E-10 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Root vegetables ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 3.40E-06 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Soil ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 9.94E-09 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Soil inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

Design Analyses and Calculation Page 90 of 125 Form Atkins-NS-EN-13-03 R3 XE133m 0.00E+00 0.00%

Design Analyses and Calculation Page 91 of 125 Form Atkins-NS-EN-13-03 R3 COW MILK OUTPUT FILE - MEI

  • File: c:\\frames\\shine\\sbcows30.epa
  • Section: nes15
  • Date: 3/18/2015 6:13:53 PM GENII VERSION 2

SUMMARY

REPORT FOR CASE: c:\\frames\\shine\\sbcows30 -----------------------------

FOR IMPACT ICON: hei14 THE HEALTH IMPACTS FILE FOR THIS CASE CONTAINS INFORMATION ON:

4 AGE GROUP(S) 6 RADIONUCLIDES (COUNTING DECAY PROGENY SEPARATELY IN CHAINS) 1 ORGAN(S)/TISSUE(S) FOR RADIATION DOSE 1 POTENTIAL CANCER SITES

SUMMARY

OF CASE INPUT DATA ---------------------------------------------------------------------------

SUMMARY

OF INPUT DATA FOR ATMOSPHERIC RELEASES -------------------------------------------------------

FOR LOCATION usr9 THE RELEASE IS Point EXIT AREA, M2: 1.00E-01 EXIT HEIGHT, M: 1.00E+01 HEIGHT OF ADJACENT BUILDING, M: 1.00E+01 EXIT VELOCITY, M/S: 0.00E+00 EXIT TEMPERATURE, DEGREE C: 9.30E+00 AMBIENT TEMPERATURE, DEGREE C; 9.30E+00 RELEASE MEDIUM 1 IS A GAS WITH NON-DEPOSITING FRACTION 5.00E-01 RELEASE PARTICLE 2 HAS RADIUS 3.00E+00 um RADIONUCLIDE TIME GAS PARTICLE 1 PARTICLE 2 PARTICLE 3 RELEASE RATE (yr) (pCi/yr) (pCi/yr) (pCi/yr) (pCi/yr)

AR41 0.00E+00 1.52E+13 0.00E+00 0.00E+00 0.00E+00 1.00E+00 1.52E+13 0.00E+00 0.00E+00 0.00E+00 I131 0.00E+00 6.65E+11 2.85E+11 0.00E+00 0.00E+00 1.00E+00 6.65E+11 2.85E+11 0.00E+00 0.00E+00 KR85 0.00E+00 1.20E+14 0.00E+00 0.00E+00 0.00E+00 1.00E+00 1.20E+14 0.00E+00 0.00E+00 0.00E+00 XE131m 0.00E+00 5.53E+14 0.00E+00 0.00E+00 0.00E+00 1.00E+00 5.53E+14 0.00E+00 0.00E+00 0.00E+00 XE133 0.00E+00 1.08E+16 0.00E+00 0.00E+00 0.00E+00 1.00E+00 1.08E+16 0.00E+00 0.00E+00 0.00E+00 XE133m 0.00E+00 4.08E+11 0.00E+00 0.00E+00 0.00E+00 1.00E+00 4.08E+11 0.00E+00 0.00E+00 0.00E+00

SUMMARY

OF ATMOSPHERIC TRANSPORT RESULTS FOR MODULE air10 ------------------

METEOROLOGICAL DATA TAKEN FROM FILE: NOT FOUND DISPERSION PARAMETERIZATION 0 data set was not found, NLINES =$__7 MINIMUM WIND SPEED DURING PLUME RISE 0.00 M/S SIGMA TO SHIFT TO SEMI-INFINITE CLOUD SHINE 0.00 M

Design Analyses and Calculation Page 92 of 125 Form Atkins-NS-EN-13-03 R3 TRANSFER RESISTENCE FOR IODINE 0.00 S/M TRANSFER RESISTENCE FOR PARTICLES 0.00 S/M MAXIMUM WIND SPEED FOR CALM 0.00 M/S

SUMMARY

OF INPUT DATA FOR EXPOSURE MODULE exp12 ------------------------

TERRESTRIAL ACCUMULATION TIME LINE:

START OF RELEASE (YEARS BEFORE INITIAL EXPOSURE): 15.

DURATION OF RELEASE (YEARS SINCE INITIAL RELEASE): 30.

DURATION OF EXPOSURE (YEARS): 1.

GENERAL ENVIRONMENTAL BEHAVIOR CONTROLS:

TYPE OF RESUSPENSION MODEL: None TYPE OF SOIL LEACHING MODEL: Calculated From User Input TYPE OF AIR SUBMERSION MODEL: Infinite Plume INADVERTANT SOIL INGESTION PATHWAY: ON ESTIMATION OF INDOOR AIR CONCENTRATIONS: ON ESTIMATION OF OUTDOOR SOIL EXTERNAL DOSE RATES: ON HARVEST REMOVAL OF CONTAMINANTS FROM SOIL: ON ABSOLUTE HUMIDITY FOR H-3 CALCULATIONS, KG/M3: 8.00E-03 FRACTION OF ROOTS IN SURFACE SOILS: 1.00E+00 SURFACE SOIL DENSITY, KG/M3: 1.60E+03 WEATHERING RATE HALF-TIME FOR VEGETATION, DAYS: 1.40E+01 AVERAGE RAINFALL RATE (WHEN RAINING), MM/DAY: 2.42E+00 RESUSPENSION FACTOR FOR SOIL-TO-PLANT, 1/M: 1.00E-09 LOCAL DEPOSITION VELOCITY FOR RESUSPENDED SOIL, M/S: 1.00E-03 SURFACE SOIL AREAL DENSITY, KG/M2: 2.40E+02 SURFACE SOIL LAYER THICKNESS, M: 1.50E+01 GROW STANDING YIELD INTAKE DRY-TO-WET TRANSLOCATION TIME BIOMASS (KG/M2) DELAY RATIO FACTOR TERRESTRIAL FOODS (DAYS) (KG/M2) (DAYS)

LEAFY VEG 60. 2.00 2.00 1.00 0.10 1.00 OTHER VEG 60. 2.00 2.00 60.00 0.20 0.10 FRUIT 60. 3.00 2.00 60.00 0.20 0.10 GRAIN 60. 1.60 2.00 60.00 0.88 0.10 GROW STANDING YIELD STORAGE DRY-TO-WET TRANSLOCATION DIET CONSUMPTION SOIL INTAKE TIME BIOMASS (KG/M2) TIME RATIO FACTOR FRACTION RATE INTAKE DELAY ANIMAL PRODUCTS (DAYS) (KG/M2) (DAYS) (KG/D) (KG/D) (DAYS)

STORED FEED MEAT 90. 1.60 0.80 90.00 0.88 0.10 1.00 17.00 1.00 20.00 POULTRY 90. 1.60 0.80 180.00 0.88 0.10 1.00 0.12 0.00 1.00 MILK 30. 1.00 0.70 90.00 0.20 1.00 1.00 14.00 1.00 1.00 EGGS 90. 1.60 0.80 180.00 0.88 0.10 1.00 0.12 0.00 1.00 FRESH FORAGE MEAT ANIMAL 45. 1.00 2.00 0.00 0.20 1.00 1.00 51.00 MILK COW 30. 1.50 0.70 0.00 0.20 1.00 1.00 41.00

SUMMARY

OF INPUT DATA FROM RECEPTOR MODULE rcp13 -------------------------

FOR AGE GROUP 1 THE LOWER AGE LIMIT IS 0.0 AND THE UPPER AGE LIMIT IS 1.0 YEARS.

Design Analyses and Calculation Page 93 of 125 Form Atkins-NS-EN-13-03 R3 FOR AGE GROUP 2 THE LOWER AGE LIMIT IS 1.0 AND THE UPPER AGE LIMIT IS 11.0 YEARS.

FOR AGE GROUP 3 THE LOWER AGE LIMIT IS 11.0 AND THE UPPER AGE LIMIT IS 17.0 YEARS.

FOR AGE GROUP 4 THE LOWER AGE LIMIT IS 17.0 AND THE UPPER AGE LIMIT IS 70.0 YEARS.

FOR AGE GROUP 1 DAILY PLUME IMMERSION EXPOSURE TIME IS 24.0 HOURS/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 2 DAILY PLUME IMMERSION EXPOSURE TIME IS 24.0 HOURS/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 DAILY PLUME IMMERSION EXPOSURE TIME IS 24.0 HOURS/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 DAILY PLUME IMMERSION EXPOSURE TIME IS 24.0 HOURS/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 DAILY SOIL EXTERNAL EXPOSURE TIME IS 24.0 HOURS/DAY FOR 182.5 DAYS/YEAR, WITH FRACTIONS OF TIME INDOORS/OUTDOORS OF 0.700/0.300 FOR AGE GROUP 2 DAILY SOIL EXTERNAL EXPOSURE TIME IS 24.0 HOURS/DAY FOR 182.5 DAYS/YEAR, WITH FRACTIONS OF TIME INDOORS/OUTDOORS OF 0.700/0.300 FOR AGE GROUP 3 DAILY SOIL EXTERNAL EXPOSURE TIME IS 24.0 HOURS/DAY FOR 182.5 DAYS/YEAR, WITH FRACTIONS OF TIME INDOORS/OUTDOORS OF 0.700/0.300 FOR AGE GROUP 4 DAILY SOIL EXTERNAL EXPOSURE TIME IS 24.0 HOURS/DAY FOR 182.5 DAYS/YEAR, WITH FRACTIONS OF TIME INDOORS/OUTDOORS OF 0.700/0.300 THE SHIELDING FACTORS FOR INDOOR AND OUTDOOR EXPOSURE ARE 0.700 AND 1.000 FOR AGE GROUP 1 CONSUMPTION OF LEAFY VEG IS 0.000 KG/DAY FOR 0.0 DAYS/YEAR FOR AGE GROUP 2 CONSUMPTION OF LEAFY VEG IS 0.071 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 CONSUMPTION OF LEAFY VEG IS 0.115 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 CONSUMPTION OF LEAFY VEG IS 0.148 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 CONSUMPTION OF OTHER VEG IS 0.000 KG/DAY FOR 0.0 DAYS/YEAR FOR AGE GROUP 2 CONSUMPTION OF OTHER VEG IS 0.769 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 CONSUMPTION OF OTHER VEG IS 0.931 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 CONSUMPTION OF OTHER VEG IS 0.769 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 CONSUMPTION OF FRUIT IS 0.000 KG/DAY FOR 0.0 DAYS/YEAR FOR AGE GROUP 2 CONSUMPTION OF FRUIT IS 0.313 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 CONSUMPTION OF FRUIT IS 0.379 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 CONSUMPTION OF FRUIT IS 0.313 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 CONSUMPTION OF GRAIN IS 0.000 KG/DAY FOR 0.0 DAYS/YEAR FOR AGE GROUP 2 CONSUMPTION OF GRAIN IS 0.342 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 CONSUMPTION OF GRAIN IS 0.414 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 CONSUMPTION OF GRAIN IS 0.342 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 CONSUMPTION OF MEAT IS 0.000 KG/DAY FOR 0.0 DAYS/YEAR FOR AGE GROUP 2 CONSUMPTION OF MEAT IS 0.112 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 CONSUMPTION OF MEAT IS 0.178 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 CONSUMPTION OF MEAT IS 0.301 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 CONSUMPTION OF POULTRY IS 0.000 KG/DAY FOR 0.0 DAYS/YEAR FOR AGE GROUP 2 CONSUMPTION OF POULTRY IS 0.049 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 CONSUMPTION OF POULTRY IS 0.049 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 CONSUMPTION OF POULTRY IS 0.049 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 CONSUMPTION OF MILK IS 0.904 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 2 CONSUMPTION OF MILK IS 0.900 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 CONSUMPTION OF MILK IS 1.100 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 CONSUMPTION OF MILK IS 0.840 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 CONSUMPTION OF EGGS IS 0.000 KG/DAY FOR 0.0 DAYS/YEAR FOR AGE GROUP 2 CONSUMPTION OF EGGS IS 0.032 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 CONSUMPTION OF EGGS IS 0.032 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 CONSUMPTION OF EGGS IS 0.032 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 CONSUMPTION OF SOIL IS 1.00E+02 MILLIGRAMS/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 2 CONSUMPTION OF SOIL IS 1.00E+02 MILLIGRAMS/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 CONSUMPTION OF SOIL IS 1.00E+02 MILLIGRAMS/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 CONSUMPTION OF SOIL IS 1.00E+02 MILLIGRAMS/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 OUTDOOR INHALATION RATE IS 3.83 M3/DAY FOR 365.0 DAYS/YEAR, WITH A FRACTION OF A DAY OUTDOORS OF 0.250 FOR AGE GROUP 2 OUTDOOR INHALATION RATE IS 10.13 M3/DAY FOR 365.0 DAYS/YEAR, WITH A FRACTION OF A DAY OUTDOORS OF 0.250 FOR AGE GROUP 3 OUTDOOR INHALATION RATE IS 21.90 M3/DAY FOR 365.0 DAYS/YEAR, WITH A FRACTION OF A DAY OUTDOORS OF 0.250 FOR AGE GROUP 4 OUTDOOR INHALATION RATE IS 21.90 M3/DAY FOR 365.0 DAYS/YEAR, WITH A FRACTION OF A DAY OUTDOORS OF 0.250 FOR AGE GROUP 1 INDOOR INHALATION RATE IS 3.83 M3/DAY FOR 365.0 DAYS/YEAR,

Design Analyses and Calculation Page 94 of 125 Form Atkins-NS-EN-13-03 R3 WITH A FRACTION OF A DAY INDOORS OF 0.750 FOR AGE GROUP 2 INDOOR INHALATION RATE IS 10.13 M3/DAY FOR 365.0 DAYS/YEAR, WITH A FRACTION OF A DAY INDOORS OF 0.750 FOR AGE GROUP 3 INDOOR INHALATION RATE IS 21.90 M3/DAY FOR 365.0 DAYS/YEAR, WITH A FRACTION OF A DAY INDOORS OF 0.750 FOR AGE GROUP 4 INDOOR INHALATION RATE IS 21.90 M3/DAY FOR 365.0 DAYS/YEAR, WITH A FRACTION OF A DAY INDOORS OF 0.750 ADDITIONAL NOTES:

Napier 2002 S&L 2012-03856 assumed 0 S&L 2012-03856 assumed exit height of 10 m.

Assumed equivalent to exit height of source Assumed 0 m/s consistent with S&L 2012-03856 Set equal to ambient temperature for non-heated release Assume average of average temperatures reported in PSAR Table 19.3.2-20 Reg Guide 1.109 stipulates 1 year duration Reg Guide 1-109 stipulates 1 year exposure Reg Guide 1.109 accumulation time + exposure time Reg Guide 1.109 stipulates 15 year accumulation Duration of release period set at lifetime of operating license per PSAR RG 1.109 Eq C-6: half the radioiodine emissions considered nonelemental.

Average from PSAR Tables 19.3.2-2 and 19.3.2-3 Reg Guide 1.109 Table E-15 Based on assumed values for areal density and surface soil layer thickness Reg Guide 1.109 Table E-15 Time Delay between harvest and ingestion Reg Guide 1.109 Table E-15 Agricultural productivity by unit area Reg Guide 1.109 Table E-15 Period of Growing Season Reg Guide 1.109 Table E-15 Agricultural Productivity Reg Guide 1.109 Table E-15 Time deal ingestion of crops by man Reg Guide 1.109 Table E-15 Ave time from slaughter of meat animal to consumption Reg Guide 1.109 TAble E-15 Attenuation Factor for shielding provided by residential structure Reg Guide 1.109 Table E-5 Infant Intake Reg Guide 1.109 Table E-5 Child Consumption Reg Guide 1.109 Table E-5 Teen Consumption Reg Guide 1.109 Table E-15 Adult Consumption 1 EXPOSURE PERIOD(S).

INDIVIDUAL DOSE CALCULATION ONLY, NO POPULATION TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

MAXIMUM POINT = 277 CORRESPONDING TO DIRECTION 13 AND DISTANCE 1 AT LOCATION X= 0.0 KM; Y=

0.0 KM INDIVIDUAL AGE RANGE 0 TO 1 YEARS MAXIMUM EXPOSED INDIVIDUAL LOCATION ORGAN MAX. DOSE (rem )

total body 6.95E-03 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

INDIVIDUAL AGE RANGE 0 TO 1 YEARS INDIVIDUAL EFFECTIVE DOSE BY DISTANCE AND DIRECTION (rem )

388498.

647497.1294994.1942491.2589988.3884982.5179976.6474970.7769964.9064958.*************************************

0. 3.4E-03 1.6E-03 5.2E-04 2.7E-04 1.7E-04 8.5E-05 5.4E-05 3.8E-05 2.9E-05 2.3E-05 1.9E-05 1.6E-05 1.3E-05 7.4E-06 4.9E-06 2.8E-06 1.9E-06 1.4E-06 1.1E-06 8.9E-07 7.5E-07 6.4E-07 5.6E-07
22. 1.9E-03 8.9E-04 2.9E-04 1.5E-04 9.1E-05 4.7E-05 3.0E-05 2.1E-05 1.6E-05 1.2E-05 1.0E-05 8.4E-06 7.1E-06 3.9E-06 2.6E-06 1.5E-06 9.9E-07 7.2E-07 5.6E-07 4.6E-07 3.8E-07 3.2E-07 2.8E-07

Design Analyses and Calculation Page 95 of 125 Form Atkins-NS-EN-13-03 R3

45. 2.3E-03 1.1E-03 3.5E-04 1.7E-04 1.1E-04 5.6E-05 3.5E-05 2.5E-05 1.8E-05 1.5E-05 1.2E-05 9.9E-06 8.5E-06 4.6E-06 3.1E-06 1.7E-06 1.2E-06 8.6E-07 6.7E-07 5.4E-07 4.5E-07 3.9E-07 3.4E-07
68. 1.9E-03 1.3E-03 4.2E-04 2.1E-04 1.3E-04 6.9E-05 4.4E-05 3.1E-05 2.3E-05 1.8E-05 1.5E-05 1.3E-05 1.1E-05 6.0E-06 4.0E-06 2.3E-06 1.5E-06 1.1E-06 8.9E-07 7.3E-07 6.1E-07 5.2E-07 4.5E-07
90. 3.0E-03 2.1E-03 6.8E-04 3.4E-04 2.1E-04 1.1E-04 7.1E-05 5.0E-05 3.8E-05 3.0E-05 2.5E-05 2.1E-05 1.8E-05 1.0E-05 6.8E-06 3.9E-06 2.6E-06 2.0E-06 1.5E-06 1.3E-06 1.1E-06 9.1E-07 7.9E-07 112. 3.3E-03 1.7E-03 5.6E-04 2.8E-04 1.8E-04 9.3E-05 5.9E-05 4.2E-05 3.2E-05 2.6E-05 2.1E-05 1.8E-05 1.5E-05 8.6E-06 5.8E-06 3.3E-06 2.3E-06 1.7E-06 1.3E-06 1.1E-06 9.3E-07 7.9E-07 7.0E-07 135. 2.9E-03 1.4E-03 4.8E-04 2.4E-04 1.5E-04 7.9E-05 5.1E-05 3.6E-05 2.8E-05 2.2E-05 1.8E-05 1.5E-05 1.3E-05 7.4E-06 5.0E-06 2.9E-06 2.0E-06 1.5E-06 1.2E-06 9.6E-07 8.0E-07 6.9E-07 6.0E-07 158. 2.8E-03 1.3E-03 4.2E-04 2.1E-04 1.3E-04 6.9E-05 4.4E-05 3.1E-05 2.3E-05 1.8E-05 1.5E-05 1.3E-05 1.1E-05 6.0E-06 4.0E-06 2.3E-06 1.6E-06 1.2E-06 9.0E-07 7.3E-07 6.2E-07 5.3E-07 4.6E-07 180. 4.9E-03 2.1E-03 7.0E-04 3.6E-04 2.2E-04 1.1E-04 7.3E-05 5.1E-05 3.9E-05 3.1E-05 2.5E-05 2.1E-05 1.8E-05 9.9E-06 6.6E-06 3.8E-06 2.5E-06 1.9E-06 1.5E-06 1.2E-06 1.0E-06 8.5E-07 7.4E-07 202. 4.2E-03 1.9E-03 6.1E-04 3.1E-04 1.9E-04 9.9E-05 6.3E-05 4.4E-05 3.3E-05 2.6E-05 2.1E-05 1.8E-05 1.5E-05 8.3E-06 5.6E-06 3.2E-06 2.1E-06 1.6E-06 1.2E-06 1.0E-06 8.3E-07 7.1E-07 6.2E-07 225. 2.4E-03 1.5E-03 4.8E-04 2.4E-04 1.5E-04 7.7E-05 4.8E-05 3.4E-05 2.6E-05 2.0E-05 1.6E-05 1.4E-05 1.2E-05 6.4E-06 4.2E-06 2.4E-06 1.6E-06 1.2E-06 9.3E-07 7.5E-07 6.3E-07 5.4E-07 4.7E-07 248. 3.2E-03 1.4E-03 4.7E-04 2.4E-04 1.5E-04 7.8E-05 4.9E-05 3.5E-05 2.6E-05 2.1E-05 1.7E-05 1.4E-05 1.2E-05 6.8E-06 4.6E-06 2.6E-06 1.8E-06 1.3E-06 1.0E-06 8.3E-07 7.0E-07 5.9E-07 5.2E-07 270. 6.9E-03 3.0E-03 1.0E-03 5.0E-04 3.1E-04 1.6E-04 1.0E-04 7.4E-05 5.6E-05 4.5E-05 3.7E-05 3.1E-05 2.6E-05 1.5E-05 1.0E-05 5.8E-06 3.9E-06 2.9E-06 2.3E-06 1.9E-06 1.6E-06 1.4E-06 1.2E-06 292. 4.5E-03 2.0E-03 6.7E-04 3.4E-04 2.1E-04 1.1E-04 7.1E-05 5.0E-05 3.8E-05 3.0E-05 2.5E-05 2.1E-05 1.8E-05 1.0E-05 6.7E-06 3.9E-06 2.6E-06 1.9E-06 1.5E-06 1.3E-06 1.1E-06 9.0E-07 7.9E-07 315. 4.0E-03 1.9E-03 6.1E-04 3.1E-04 1.9E-04 9.9E-05 6.3E-05 4.4E-05 3.3E-05 2.6E-05 2.2E-05 1.8E-05 1.5E-05 8.5E-06 5.7E-06 3.3E-06 2.2E-06 1.6E-06 1.3E-06 1.0E-06 8.8E-07 7.5E-07 6.6E-07 338. 3.1E-03 1.4E-03 4.6E-04 2.3E-04 1.5E-04 7.5E-05 4.8E-05 3.4E-05 2.5E-05 2.0E-05 1.6E-05 1.4E-05 1.2E-05 6.5E-06 4.3E-06 2.5E-06 1.7E-06 1.2E-06 9.6E-07 7.8E-07 6.5E-07 5.6E-07 4.9E-07 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

MAXIMUM LOCATION = 277 INDIVIDUAL EFFECTIVE DOSE AND RISK BY NUCLIDE NUCLIDE DOSE (rem ) CANCER INCIDENCE CANCER FATALITIES INDIVIDUAL AGE RANGE 0 TO 1 YEARS AR41 2.61E-04 0.00E+00 0.00E+00 I131 2.21E-03 0.00E+00 0.00E+00 KR85 3.74E-06 0.00E+00 0.00E+00 XE131m 5.66E-05 0.00E+00 0.00E+00 XE133 4.41E-03 0.00E+00 0.00E+00 XE133m 1.47E-07 0.00E+00 0.00E+00 EFFECTIVE DOSE (rem )BY RELEASE CATEGORY AT MAXIMUM INDIVIDUAL LOCATION:

TRITIUM (PLUS OBT) : 0.00E+00 CARBON-14 : 0.00E+00 NOBLE GASES : 4.73E-03 IODINE RADIONUCLIDES: 2.21E-03 PARTICULATE NUCLIDES: 0.00E+00 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

INDIVIDUAL AGE RANGE 0 TO 1 YEARS MAXIMUM LOCATION = 277 INDIVIDUAL EFFECTIVE DOSE AND RISK BY EXPOSURE PATHWAY PATHWAY ROUTE DOSE (rem ) CANCER INCIDENCE CANCER FATALITIES Air external 4.74E-03 0.00E+00 0.00E+00 Air inhalation 2.46E-05 0.00E+00 0.00E+00 Eggs ingestion 0.00E+00 0.00E+00 0.00E+00 Fruit ingestion 0.00E+00 0.00E+00 0.00E+00 Grain ingestion 0.00E+00 0.00E+00 0.00E+00 Ground external 2.12E-05 0.00E+00 0.00E+00 Indoor air inhalation 7.39E-05 0.00E+00 0.00E+00

Design Analyses and Calculation Page 96 of 125 Form Atkins-NS-EN-13-03 R3 Leafy vegetables ingestion 0.00E+00 0.00E+00 0.00E+00 Meat ingestion 0.00E+00 0.00E+00 0.00E+00 Milk ingestion 2.09E-03 0.00E+00 0.00E+00 Poultry ingestion 0.00E+00 0.00E+00 0.00E+00 Root vegetables ingestion 0.00E+00 0.00E+00 0.00E+00 Soil ingestion 9.94E-09 0.00E+00 0.00E+00 Soil inhalation 0.00E+00 0.00E+00 0.00E+00 INDIVIDUAL EFFECTIVE DOSE AND RISK BY PATHWAY BY RADIONUCLIDE INDIVIDUAL DOSE FOR PATHWAY: Air external DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 2.61E-04 5.51%

I131 4.54E-06 0.10%

KR85 3.74E-06 0.08%

XE131m 5.66E-05 1.20%

XE133 4.41E-03 93.12%

XE133m 1.47E-07 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Air inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 2.46E-05 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Eggs ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Fruit ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Grain ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Ground external DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 2.12E-05 99.94%

KR85 0.00E+00 0.00%

XE131m 1.18E-08 0.06%

Design Analyses and Calculation Page 97 of 125 Form Atkins-NS-EN-13-03 R3 XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Indoor air inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 7.39E-05 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Leafy vegetables ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Meat ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Milk ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 2.09E-03 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Poultry ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Root vegetables ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Soil ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 9.94E-09 100.00%

Design Analyses and Calculation Page 98 of 125 Form Atkins-NS-EN-13-03 R3 KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Soil inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

1 EXPOSURE PERIOD(S).

INDIVIDUAL DOSE CALCULATION ONLY, NO POPULATION TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

MAXIMUM POINT = 277 CORRESPONDING TO DIRECTION 13 AND DISTANCE 1 AT LOCATION X= 0.0 KM; Y=

0.0 KM INDIVIDUAL AGE RANGE 1 TO 11 YEARS MAXIMUM EXPOSED INDIVIDUAL LOCATION ORGAN MAX. DOSE (rem )

total body 7.67E-03 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

INDIVIDUAL AGE RANGE 1 TO 11 YEARS INDIVIDUAL EFFECTIVE DOSE BY DISTANCE AND DIRECTION (rem )

388498.

647497.1294994.1942491.2589988.3884982.5179976.6474970.7769964.9064958.*************************************

0. 3.8E-03 1.8E-03 5.8E-04 3.0E-04 1.8E-04 9.5E-05 6.0E-05 4.2E-05 3.2E-05 2.5E-05 2.1E-05 1.7E-05 1.5E-05 8.0E-06 5.3E-06 3.0E-06 2.0E-06 1.5E-06 1.2E-06 9.5E-07 7.9E-07 6.8E-07 5.9E-07
22. 2.1E-03 9.9E-04 3.3E-04 1.6E-04 1.0E-04 5.2E-05 3.3E-05 2.3E-05 1.7E-05 1.4E-05 1.1E-05 9.2E-06 7.9E-06 4.3E-06 2.8E-06 1.6E-06 1.1E-06 7.8E-07 6.0E-07 4.9E-07 4.1E-07 3.5E-07 3.0E-07
45. 2.6E-03 1.2E-03 3.9E-04 2.0E-04 1.2E-04 6.2E-05 3.9E-05 2.7E-05 2.0E-05 1.6E-05 1.3E-05 1.1E-05 9.3E-06 5.1E-06 3.4E-06 1.9E-06 1.3E-06 9.2E-07 7.2E-07 5.8E-07 4.8E-07 4.1E-07 3.6E-07
68. 2.1E-03 1.4E-03 4.7E-04 2.4E-04 1.5E-04 7.6E-05 4.8E-05 3.4E-05 2.6E-05 2.0E-05 1.7E-05 1.4E-05 1.2E-05 6.5E-06 4.3E-06 2.5E-06 1.7E-06 1.2E-06 9.5E-07 7.7E-07 6.5E-07 5.5E-07 4.8E-07
90. 3.3E-03 2.3E-03 7.4E-04 3.8E-04 2.3E-04 1.2E-04 7.8E-05 5.5E-05 4.2E-05 3.3E-05 2.7E-05 2.3E-05 1.9E-05 1.1E-05 7.2E-06 4.2E-06 2.8E-06 2.1E-06 1.6E-06 1.3E-06 1.1E-06 9.6E-07 8.3E-07 112. 3.6E-03 1.8E-03 6.1E-04 3.1E-04 1.9E-04 1.0E-04 6.4E-05 4.6E-05 3.5E-05 2.8E-05 2.3E-05 1.9E-05 1.6E-05 9.2E-06 6.2E-06 3.6E-06 2.4E-06 1.8E-06 1.4E-06 1.2E-06 9.7E-07 8.3E-07 7.3E-07 135. 3.2E-03 1.6E-03 5.3E-04 2.7E-04 1.7E-04 8.7E-05 5.6E-05 3.9E-05 3.0E-05 2.4E-05 2.0E-05 1.6E-05 1.4E-05 7.9E-06 5.3E-06 3.1E-06 2.1E-06 1.6E-06 1.2E-06 1.0E-06 8.4E-07 7.2E-07 6.3E-07 158. 3.1E-03 1.4E-03 4.7E-04 2.4E-04 1.5E-04 7.6E-05 4.8E-05 3.4E-05 2.6E-05 2.0E-05 1.7E-05 1.4E-05 1.2E-05 6.5E-06 4.4E-06 2.5E-06 1.7E-06 1.2E-06 9.6E-07 7.8E-07 6.5E-07 5.6E-07 4.9E-07 180. 5.4E-03 2.4E-03 7.9E-04 4.0E-04 2.5E-04 1.3E-04 8.1E-05 5.7E-05 4.3E-05 3.4E-05 2.7E-05 2.3E-05 2.0E-05 1.1E-05 7.2E-06 4.0E-06 2.7E-06 2.0E-06 1.6E-06 1.3E-06 1.1E-06 9.0E-07 7.9E-07 202. 4.6E-03 2.1E-03 6.9E-04 3.5E-04 2.1E-04 1.1E-04 7.0E-05 4.9E-05 3.7E-05 2.9E-05 2.4E-05 2.0E-05 1.7E-05 9.1E-06 6.1E-06 3.4E-06 2.3E-06 1.7E-06 1.3E-06 1.1E-06 8.9E-07 7.6E-07 6.6E-07 225. 2.7E-03 1.6E-03 5.3E-04 2.7E-04 1.7E-04 8.6E-05 5.4E-05 3.8E-05 2.8E-05 2.2E-05 1.8E-05 1.5E-05 1.3E-05 7.0E-06 4.6E-06 2.6E-06 1.7E-06 1.3E-06 1.0E-06 8.0E-07 6.7E-07 5.7E-07 5.0E-07 248. 3.5E-03 1.6E-03 5.3E-04 2.7E-04 1.7E-04 8.6E-05 5.5E-05 3.9E-05 2.9E-05 2.3E-05 1.9E-05 1.6E-05 1.3E-05 7.3E-06 4.9E-06 2.8E-06 1.9E-06 1.4E-06 1.1E-06 8.8E-07 7.4E-07 6.3E-07 5.5E-07 270. 7.7E-03 3.3E-03 1.1E-03 5.5E-04 3.5E-04 1.8E-04 1.1E-04 8.1E-05 6.1E-05 4.9E-05 4.0E-05 3.3E-05 2.9E-05 1.6E-05 1.1E-05 6.1E-06 4.2E-06 3.1E-06 2.4E-06 2.0E-06 1.7E-06 1.4E-06 1.2E-06 292. 4.9E-03 2.3E-03 7.5E-04 3.8E-04 2.3E-04 1.2E-04 7.8E-05 5.5E-05 4.2E-05 3.3E-05 2.7E-05 2.3E-05 1.9E-05 1.1E-05 7.2E-06 4.1E-06 2.8E-06 2.1E-06 1.6E-06 1.3E-06 1.1E-06 9.5E-07 8.4E-07

Design Analyses and Calculation Page 99 of 125 Form Atkins-NS-EN-13-03 R3 315. 4.4E-03 2.1E-03 6.8E-04 3.4E-04 2.1E-04 1.1E-04 6.9E-05 4.9E-05 3.7E-05 2.9E-05 2.4E-05 2.0E-05 1.7E-05 9.3E-06 6.2E-06 3.5E-06 2.4E-06 1.7E-06 1.4E-06 1.1E-06 9.3E-07 8.0E-07 6.9E-07 338. 3.4E-03 1.6E-03 5.2E-04 2.6E-04 1.6E-04 8.4E-05 5.3E-05 3.7E-05 2.8E-05 2.2E-05 1.8E-05 1.5E-05 1.3E-05 7.0E-06 4.7E-06 2.7E-06 1.8E-06 1.3E-06 1.0E-06 8.3E-07 6.9E-07 5.9E-07 5.1E-07 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

MAXIMUM LOCATION = 277 INDIVIDUAL EFFECTIVE DOSE AND RISK BY NUCLIDE NUCLIDE DOSE (rem ) CANCER INCIDENCE CANCER FATALITIES INDIVIDUAL AGE RANGE 1 TO 11 YEARS AR41 2.61E-04 0.00E+00 0.00E+00 I131 2.94E-03 0.00E+00 0.00E+00 KR85 3.74E-06 0.00E+00 0.00E+00 XE131m 5.66E-05 0.00E+00 0.00E+00 XE133 4.41E-03 0.00E+00 0.00E+00 XE133m 1.47E-07 0.00E+00 0.00E+00 EFFECTIVE DOSE (rem )BY RELEASE CATEGORY AT MAXIMUM INDIVIDUAL LOCATION:

TRITIUM (PLUS OBT) : 0.00E+00 CARBON-14 : 0.00E+00 NOBLE GASES : 4.73E-03 IODINE RADIONUCLIDES: 2.94E-03 PARTICULATE NUCLIDES: 0.00E+00 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

INDIVIDUAL AGE RANGE 1 TO 11 YEARS MAXIMUM LOCATION = 277 INDIVIDUAL EFFECTIVE DOSE AND RISK BY EXPOSURE PATHWAY PATHWAY ROUTE DOSE (rem ) CANCER INCIDENCE CANCER FATALITIES Air external 4.74E-03 0.00E+00 0.00E+00 Air inhalation 6.51E-05 0.00E+00 0.00E+00 Eggs ingestion 1.28E-08 0.00E+00 0.00E+00 Fruit ingestion 9.22E-07 0.00E+00 0.00E+00 Grain ingestion 1.89E-06 0.00E+00 0.00E+00 Ground external 2.12E-05 0.00E+00 0.00E+00 Indoor air inhalation 1.96E-04 0.00E+00 0.00E+00 Leafy vegetables ingestion 5.08E-04 0.00E+00 0.00E+00 Meat ingestion 4.61E-05 0.00E+00 0.00E+00 Milk ingestion 2.09E-03 0.00E+00 0.00E+00 Poultry ingestion 2.23E-10 0.00E+00 0.00E+00 Root vegetables ingestion 3.40E-06 0.00E+00 0.00E+00 Soil ingestion 9.94E-09 0.00E+00 0.00E+00 Soil inhalation 0.00E+00 0.00E+00 0.00E+00 INDIVIDUAL EFFECTIVE DOSE AND RISK BY PATHWAY BY RADIONUCLIDE INDIVIDUAL DOSE FOR PATHWAY: Air external DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 2.61E-04 5.51%

I131 4.54E-06 0.10%

KR85 3.74E-06 0.08%

XE131m 5.66E-05 1.20%

XE133 4.41E-03 93.12%

XE133m 1.47E-07 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Air inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 6.51E-05 100.00%

KR85 0.00E+00 0.00%

Design Analyses and Calculation Page 100 of 125 Form Atkins-NS-EN-13-03 R3 XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Eggs ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.28E-08 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Fruit ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 9.22E-07 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Grain ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.89E-06 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Ground external DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 2.12E-05 99.94%

KR85 0.00E+00 0.00%

XE131m 1.18E-08 0.06%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Indoor air inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.96E-04 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Leafy vegetables ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 5.08E-04 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Meat ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

Design Analyses and Calculation Page 101 of 125 Form Atkins-NS-EN-13-03 R3 I131 4.61E-05 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Milk ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 2.09E-03 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Poultry ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 2.23E-10 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Root vegetables ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 3.40E-06 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Soil ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 9.94E-09 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Soil inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

1 EXPOSURE PERIOD(S).

INDIVIDUAL DOSE CALCULATION ONLY, NO POPULATION TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

MAXIMUM POINT = 277 CORRESPONDING TO DIRECTION 13 AND DISTANCE 1 AT LOCATION X= 0.0 KM; Y=

0.0 KM INDIVIDUAL AGE RANGE 11 TO 17 YEARS MAXIMUM EXPOSED INDIVIDUAL LOCATION

Design Analyses and Calculation Page 102 of 125 Form Atkins-NS-EN-13-03 R3 ORGAN MAX. DOSE (rem )

total body 8.77E-03 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

INDIVIDUAL AGE RANGE 11 TO 17 YEARS INDIVIDUAL EFFECTIVE DOSE BY DISTANCE AND DIRECTION (rem )

388498.

647497.1294994.1942491.2589988.3884982.5179976.6474970.7769964.9064958.*************************************

0. 4.4E-03 2.0E-03 6.7E-04 3.4E-04 2.1E-04 1.1E-04 6.9E-05 4.8E-05 3.6E-05 2.9E-05 2.3E-05 1.9E-05 1.6E-05 9.0E-06 6.0E-06 3.4E-06 2.3E-06 1.7E-06 1.3E-06 1.0E-06 8.7E-07 7.4E-07 6.4E-07
22. 2.5E-03 1.2E-03 3.8E-04 1.9E-04 1.2E-04 6.1E-05 3.8E-05 2.7E-05 2.0E-05 1.6E-05 1.3E-05 1.1E-05 9.0E-06 4.8E-06 3.2E-06 1.8E-06 1.2E-06 8.6E-07 6.7E-07 5.4E-07 4.5E-07 3.8E-07 3.3E-07
45. 3.0E-03 1.4E-03 4.5E-04 2.3E-04 1.4E-04 7.2E-05 4.5E-05 3.2E-05 2.4E-05 1.9E-05 1.5E-05 1.2E-05 1.1E-05 5.7E-06 3.8E-06 2.1E-06 1.4E-06 1.0E-06 7.9E-07 6.4E-07 5.3E-07 4.5E-07 3.9E-07
68. 2.5E-03 1.6E-03 5.4E-04 2.7E-04 1.7E-04 8.8E-05 5.6E-05 3.9E-05 2.9E-05 2.3E-05 1.9E-05 1.6E-05 1.3E-05 7.3E-06 4.8E-06 2.7E-06 1.8E-06 1.4E-06 1.0E-06 8.5E-07 7.1E-07 6.0E-07 5.2E-07
90. 3.7E-03 2.6E-03 8.5E-04 4.3E-04 2.7E-04 1.4E-04 8.8E-05 6.2E-05 4.7E-05 3.7E-05 3.0E-05 2.5E-05 2.2E-05 1.2E-05 8.0E-06 4.6E-06 3.1E-06 2.3E-06 1.8E-06 1.5E-06 1.2E-06 1.0E-06 9.0E-07 112. 4.0E-03 2.1E-03 7.0E-04 3.5E-04 2.2E-04 1.1E-04 7.3E-05 5.2E-05 3.9E-05 3.1E-05 2.5E-05 2.1E-05 1.8E-05 1.0E-05 6.8E-06 3.9E-06 2.6E-06 2.0E-06 1.5E-06 1.3E-06 1.1E-06 9.0E-07 7.9E-07 135. 3.6E-03 1.8E-03 6.0E-04 3.0E-04 1.9E-04 9.8E-05 6.3E-05 4.4E-05 3.4E-05 2.7E-05 2.2E-05 1.8E-05 1.6E-05 8.8E-06 5.9E-06 3.4E-06 2.3E-06 1.7E-06 1.3E-06 1.1E-06 9.1E-07 7.8E-07 6.8E-07 158. 3.5E-03 1.6E-03 5.4E-04 2.7E-04 1.7E-04 8.8E-05 5.5E-05 3.9E-05 2.9E-05 2.3E-05 1.9E-05 1.6E-05 1.3E-05 7.3E-06 4.9E-06 2.8E-06 1.9E-06 1.4E-06 1.1E-06 8.6E-07 7.2E-07 6.1E-07 5.3E-07 180. 6.2E-03 2.8E-03 9.1E-04 4.6E-04 2.9E-04 1.5E-04 9.3E-05 6.5E-05 4.9E-05 3.8E-05 3.1E-05 2.6E-05 2.2E-05 1.2E-05 8.0E-06 4.5E-06 3.0E-06 2.2E-06 1.7E-06 1.4E-06 1.2E-06 9.9E-07 8.6E-07 202. 5.4E-03 2.4E-03 8.0E-04 4.0E-04 2.5E-04 1.3E-04 8.1E-05 5.7E-05 4.2E-05 3.3E-05 2.7E-05 2.2E-05 1.9E-05 1.0E-05 6.8E-06 3.8E-06 2.6E-06 1.9E-06 1.5E-06 1.2E-06 9.8E-07 8.3E-07 7.2E-07 225. 3.1E-03 1.9E-03 6.2E-04 3.2E-04 1.9E-04 1.0E-04 6.3E-05 4.4E-05 3.3E-05 2.6E-05 2.1E-05 1.7E-05 1.5E-05 7.9E-06 5.2E-06 2.9E-06 1.9E-06 1.4E-06 1.1E-06 8.9E-07 7.4E-07 6.3E-07 5.4E-07 248. 4.1E-03 1.9E-03 6.1E-04 3.1E-04 1.9E-04 9.9E-05 6.3E-05 4.4E-05 3.3E-05 2.6E-05 2.1E-05 1.8E-05 1.5E-05 8.3E-06 5.5E-06 3.1E-06 2.1E-06 1.5E-06 1.2E-06 9.7E-07 8.1E-07 6.9E-07 6.0E-07 270. 8.8E-03 3.8E-03 1.3E-03 6.4E-04 4.0E-04 2.1E-04 1.3E-04 9.2E-05 7.0E-05 5.5E-05 4.5E-05 3.8E-05 3.2E-05 1.8E-05 1.2E-05 6.8E-06 4.6E-06 3.4E-06 2.7E-06 2.2E-06 1.8E-06 1.6E-06 1.4E-06 292. 5.6E-03 2.6E-03 8.6E-04 4.3E-04 2.7E-04 1.4E-04 8.9E-05 6.3E-05 4.7E-05 3.7E-05 3.0E-05 2.6E-05 2.2E-05 1.2E-05 8.0E-06 4.6E-06 3.1E-06 2.3E-06 1.8E-06 1.5E-06 1.2E-06 1.0E-06 9.1E-07 315. 5.1E-03 2.4E-03 7.8E-04 4.0E-04 2.4E-04 1.3E-04 8.0E-05 5.6E-05 4.2E-05 3.3E-05 2.7E-05 2.3E-05 1.9E-05 1.0E-05 6.9E-06 3.9E-06 2.6E-06 1.9E-06 1.5E-06 1.2E-06 1.0E-06 8.7E-07 7.6E-07 338. 4.0E-03 1.8E-03 6.0E-04 3.0E-04 1.9E-04 9.7E-05 6.1E-05 4.3E-05 3.2E-05 2.5E-05 2.0E-05 1.7E-05 1.5E-05 7.9E-06 5.3E-06 3.0E-06 2.0E-06 1.4E-06 1.1E-06 9.1E-07 7.6E-07 6.5E-07 5.6E-07 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

MAXIMUM LOCATION = 277 INDIVIDUAL EFFECTIVE DOSE AND RISK BY NUCLIDE NUCLIDE DOSE (rem ) CANCER INCIDENCE CANCER FATALITIES INDIVIDUAL AGE RANGE 11 TO 17 YEARS AR41 2.61E-04 0.00E+00 0.00E+00 I131 4.04E-03 0.00E+00 0.00E+00 KR85 3.74E-06 0.00E+00 0.00E+00 XE131m 5.66E-05 0.00E+00 0.00E+00 XE133 4.41E-03 0.00E+00 0.00E+00 XE133m 1.47E-07 0.00E+00 0.00E+00 EFFECTIVE DOSE (rem )BY RELEASE CATEGORY AT MAXIMUM INDIVIDUAL LOCATION:

TRITIUM (PLUS OBT) : 0.00E+00 CARBON-14 : 0.00E+00 NOBLE GASES : 4.73E-03 IODINE RADIONUCLIDES: 4.04E-03 PARTICULATE NUCLIDES: 0.00E+00

Design Analyses and Calculation Page 103 of 125 Form Atkins-NS-EN-13-03 R3 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

INDIVIDUAL AGE RANGE 11 TO 17 YEARS MAXIMUM LOCATION = 277 INDIVIDUAL EFFECTIVE DOSE AND RISK BY EXPOSURE PATHWAY PATHWAY ROUTE DOSE (rem ) CANCER INCIDENCE CANCER FATALITIES Air external 4.74E-03 0.00E+00 0.00E+00 Air inhalation 1.40E-04 0.00E+00 0.00E+00 Eggs ingestion 1.28E-08 0.00E+00 0.00E+00 Fruit ingestion 1.12E-06 0.00E+00 0.00E+00 Grain ingestion 2.29E-06 0.00E+00 0.00E+00 Ground external 2.12E-05 0.00E+00 0.00E+00 Indoor air inhalation 4.22E-04 0.00E+00 0.00E+00 Leafy vegetables ingestion 8.22E-04 0.00E+00 0.00E+00 Meat ingestion 7.32E-05 0.00E+00 0.00E+00 Milk ingestion 2.55E-03 0.00E+00 0.00E+00 Poultry ingestion 2.23E-10 0.00E+00 0.00E+00 Root vegetables ingestion 4.12E-06 0.00E+00 0.00E+00 Soil ingestion 9.94E-09 0.00E+00 0.00E+00 Soil inhalation 0.00E+00 0.00E+00 0.00E+00 INDIVIDUAL EFFECTIVE DOSE AND RISK BY PATHWAY BY RADIONUCLIDE INDIVIDUAL DOSE FOR PATHWAY: Air external DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 2.61E-04 5.51%

I131 4.54E-06 0.10%

KR85 3.74E-06 0.08%

XE131m 5.66E-05 1.20%

XE133 4.41E-03 93.12%

XE133m 1.47E-07 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Air inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.40E-04 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Eggs ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.28E-08 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Fruit ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.12E-06 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Grain ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION

Design Analyses and Calculation Page 104 of 125 Form Atkins-NS-EN-13-03 R3 AR41 0.00E+00 0.00%

I131 2.29E-06 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Ground external DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 2.12E-05 99.94%

KR85 0.00E+00 0.00%

XE131m 1.18E-08 0.06%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Indoor air inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 4.22E-04 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Leafy vegetables ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 8.22E-04 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Meat ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 7.32E-05 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Milk ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 2.55E-03 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Poultry ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 2.23E-10 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

Design Analyses and Calculation Page 105 of 125 Form Atkins-NS-EN-13-03 R3 INDIVIDUAL DOSE FOR PATHWAY: Root vegetables ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 4.12E-06 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Soil ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 9.94E-09 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Soil inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

1 EXPOSURE PERIOD(S).

INDIVIDUAL DOSE CALCULATION ONLY, NO POPULATION TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

MAXIMUM POINT = 277 CORRESPONDING TO DIRECTION 13 AND DISTANCE 1 AT LOCATION X= 0.0 KM; Y=

0.0 KM INDIVIDUAL AGE RANGE 17 TO 70 YEARS MAXIMUM EXPOSED INDIVIDUAL LOCATION ORGAN MAX. DOSE (rem )

total body 8.45E-03 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

INDIVIDUAL AGE RANGE 17 TO 70 YEARS INDIVIDUAL EFFECTIVE DOSE BY DISTANCE AND DIRECTION (rem )

388498.

647497.1294994.1942491.2589988.3884982.5179976.6474970.7769964.9064958.*************************************

0. 4.2E-03 2.0E-03 6.5E-04 3.3E-04 2.0E-04 1.0E-04 6.6E-05 4.7E-05 3.5E-05 2.8E-05 2.3E-05 1.9E-05 1.6E-05 8.7E-06 5.8E-06 3.3E-06 2.2E-06 1.6E-06 1.3E-06 1.0E-06 8.5E-07 7.3E-07 6.3E-07
22. 2.4E-03 1.1E-03 3.6E-04 1.8E-04 1.1E-04 5.8E-05 3.7E-05 2.6E-05 1.9E-05 1.5E-05 1.2E-05 1.0E-05 8.6E-06 4.7E-06 3.1E-06 1.7E-06 1.2E-06 8.4E-07 6.5E-07 5.3E-07 4.4E-07 3.7E-07 3.2E-07
45. 2.8E-03 1.3E-03 4.3E-04 2.2E-04 1.3E-04 6.9E-05 4.3E-05 3.0E-05 2.3E-05 1.8E-05 1.4E-05 1.2E-05 1.0E-05 5.6E-06 3.7E-06 2.1E-06 1.4E-06 1.0E-06 7.8E-07 6.3E-07 5.2E-07 4.4E-07 3.8E-07
68. 2.4E-03 1.6E-03 5.2E-04 2.6E-04 1.6E-04 8.4E-05 5.3E-05 3.8E-05 2.8E-05 2.2E-05 1.8E-05 1.5E-05 1.3E-05 7.1E-06 4.7E-06 2.7E-06 1.8E-06 1.3E-06 1.0E-06 8.3E-07 7.0E-07 5.9E-07 5.2E-07
90. 3.6E-03 2.5E-03 8.2E-04 4.1E-04 2.6E-04 1.3E-04 8.5E-05 6.0E-05 4.6E-05 3.6E-05 3.0E-05 2.5E-05 2.1E-05 1.2E-05 7.9E-06 4.5E-06 3.0E-06 2.2E-06 1.8E-06 1.4E-06 1.2E-06 1.0E-06 8.9E-07 112. 3.9E-03 2.0E-03 6.7E-04 3.4E-04 2.1E-04 1.1E-04 7.1E-05 5.0E-05 3.8E-05 3.0E-05 2.5E-05 2.1E-05 1.8E-05 9.9E-06 6.7E-06 3.8E-06 2.6E-06 1.9E-06 1.5E-06 1.2E-06 1.0E-06 8.9E-07 7.8E-07 135. 3.5E-03 1.7E-03 5.8E-04 2.9E-04 1.8E-04 9.5E-05 6.1E-05 4.3E-05 3.3E-05 2.6E-05 2.1E-05 1.8E-05 1.5E-05 8.6E-06 5.8E-06 3.3E-06 2.3E-06 1.7E-06 1.3E-06 1.1E-06 9.0E-07 7.8E-07 6.8E-07

Design Analyses and Calculation Page 106 of 125 Form Atkins-NS-EN-13-03 R3 158. 3.4E-03 1.6E-03 5.2E-04 2.6E-04 1.6E-04 8.4E-05 5.3E-05 3.8E-05 2.8E-05 2.2E-05 1.8E-05 1.5E-05 1.3E-05 7.1E-06 4.7E-06 2.7E-06 1.8E-06 1.3E-06 1.0E-06 8.4E-07 7.0E-07 6.0E-07 5.2E-07 180. 6.0E-03 2.7E-03 8.8E-04 4.4E-04 2.7E-04 1.4E-04 8.9E-05 6.3E-05 4.7E-05 3.7E-05 3.0E-05 2.5E-05 2.2E-05 1.2E-05 7.8E-06 4.4E-06 3.0E-06 2.2E-06 1.7E-06 1.4E-06 1.1E-06 9.7E-07 8.5E-07 202. 5.1E-03 2.3E-03 7.6E-04 3.9E-04 2.4E-04 1.2E-04 7.7E-05 5.4E-05 4.1E-05 3.2E-05 2.6E-05 2.2E-05 1.8E-05 1.0E-05 6.6E-06 3.7E-06 2.5E-06 1.8E-06 1.4E-06 1.1E-06 9.6E-07 8.2E-07 7.1E-07 225. 3.0E-03 1.8E-03 6.0E-04 3.0E-04 1.9E-04 9.6E-05 6.0E-05 4.2E-05 3.1E-05 2.5E-05 2.0E-05 1.7E-05 1.4E-05 7.7E-06 5.1E-06 2.8E-06 1.9E-06 1.4E-06 1.1E-06 8.7E-07 7.2E-07 6.2E-07 5.3E-07 248. 3.9E-03 1.8E-03 5.9E-04 3.0E-04 1.8E-04 9.5E-05 6.0E-05 4.3E-05 3.2E-05 2.5E-05 2.1E-05 1.7E-05 1.5E-05 8.0E-06 5.4E-06 3.0E-06 2.0E-06 1.5E-06 1.2E-06 9.5E-07 8.0E-07 6.8E-07 5.9E-07 270. 8.4E-03 3.7E-03 1.2E-03 6.1E-04 3.8E-04 2.0E-04 1.3E-04 8.9E-05 6.7E-05 5.3E-05 4.4E-05 3.7E-05 3.1E-05 1.7E-05 1.2E-05 6.7E-06 4.5E-06 3.3E-06 2.6E-06 2.1E-06 1.8E-06 1.5E-06 1.3E-06 292. 5.4E-03 2.5E-03 8.2E-04 4.2E-04 2.6E-04 1.4E-04 8.6E-05 6.0E-05 4.6E-05 3.6E-05 2.9E-05 2.5E-05 2.1E-05 1.2E-05 7.8E-06 4.5E-06 3.0E-06 2.2E-06 1.8E-06 1.4E-06 1.2E-06 1.0E-06 9.0E-07 315. 4.9E-03 2.3E-03 7.5E-04 3.8E-04 2.3E-04 1.2E-04 7.7E-05 5.4E-05 4.1E-05 3.2E-05 2.6E-05 2.2E-05 1.8E-05 1.0E-05 6.8E-06 3.8E-06 2.6E-06 1.9E-06 1.5E-06 1.2E-06 1.0E-06 8.6E-07 7.5E-07 338. 3.8E-03 1.7E-03 5.7E-04 2.9E-04 1.8E-04 9.3E-05 5.8E-05 4.1E-05 3.1E-05 2.4E-05 2.0E-05 1.7E-05 1.4E-05 7.7E-06 5.1E-06 2.9E-06 1.9E-06 1.4E-06 1.1E-06 8.9E-07 7.5E-07 6.4E-07 5.5E-07 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

MAXIMUM LOCATION = 277 INDIVIDUAL EFFECTIVE DOSE AND RISK BY NUCLIDE NUCLIDE DOSE (rem ) CANCER INCIDENCE CANCER FATALITIES INDIVIDUAL AGE RANGE 17 TO 70 YEARS AR41 2.61E-04 0.00E+00 0.00E+00 I131 3.72E-03 0.00E+00 0.00E+00 KR85 3.74E-06 0.00E+00 0.00E+00 XE131m 5.66E-05 0.00E+00 0.00E+00 XE133 4.41E-03 0.00E+00 0.00E+00 XE133m 1.47E-07 0.00E+00 0.00E+00 EFFECTIVE DOSE (rem )BY RELEASE CATEGORY AT MAXIMUM INDIVIDUAL LOCATION:

TRITIUM (PLUS OBT) : 0.00E+00 CARBON-14 : 0.00E+00 NOBLE GASES : 4.73E-03 IODINE RADIONUCLIDES: 3.72E-03 PARTICULATE NUCLIDES: 0.00E+00 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

INDIVIDUAL AGE RANGE 17 TO 70 YEARS MAXIMUM LOCATION = 277 INDIVIDUAL EFFECTIVE DOSE AND RISK BY EXPOSURE PATHWAY PATHWAY ROUTE DOSE (rem ) CANCER INCIDENCE CANCER FATALITIES Air external 4.74E-03 0.00E+00 0.00E+00 Air inhalation 1.40E-04 0.00E+00 0.00E+00 Eggs ingestion 1.28E-08 0.00E+00 0.00E+00 Fruit ingestion 9.22E-07 0.00E+00 0.00E+00 Grain ingestion 1.89E-06 0.00E+00 0.00E+00 Ground external 2.12E-05 0.00E+00 0.00E+00 Indoor air inhalation 4.22E-04 0.00E+00 0.00E+00 Leafy vegetables ingestion 1.06E-03 0.00E+00 0.00E+00 Meat ingestion 1.24E-04 0.00E+00 0.00E+00 Milk ingestion 1.94E-03 0.00E+00 0.00E+00 Poultry ingestion 2.23E-10 0.00E+00 0.00E+00 Root vegetables ingestion 3.40E-06 0.00E+00 0.00E+00 Soil ingestion 9.94E-09 0.00E+00 0.00E+00 Soil inhalation 0.00E+00 0.00E+00 0.00E+00 INDIVIDUAL EFFECTIVE DOSE AND RISK BY PATHWAY BY RADIONUCLIDE

Design Analyses and Calculation Page 107 of 125 Form Atkins-NS-EN-13-03 R3 INDIVIDUAL DOSE FOR PATHWAY: Air external DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 2.61E-04 5.51%

I131 4.54E-06 0.10%

KR85 3.74E-06 0.08%

XE131m 5.66E-05 1.20%

XE133 4.41E-03 93.12%

XE133m 1.47E-07 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Air inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.40E-04 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Eggs ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.28E-08 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Fruit ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 9.22E-07 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Grain ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.89E-06 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Ground external DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 2.12E-05 99.94%

KR85 0.00E+00 0.00%

XE131m 1.18E-08 0.06%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Indoor air inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 4.22E-04 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

Design Analyses and Calculation Page 108 of 125 Form Atkins-NS-EN-13-03 R3 XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Leafy vegetables ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.06E-03 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Meat ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.24E-04 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Milk ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.94E-03 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Poultry ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 2.23E-10 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Root vegetables ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 3.40E-06 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Soil ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 9.94E-09 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Soil inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

Design Analyses and Calculation Page 109 of 125 Form Atkins-NS-EN-13-03 R3 XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

Design Analyses and Calculation Page 110 of 125 Form Atkins-NS-EN-13-03 R3 GOAT MILK OUTPUT FILE - NEAREST RESIDENT

  • File: c:\\frames\\shine\\nrgoat30.epa
  • Section: nes15
  • Date: 3/18/2015 6:12:40 PM GENII VERSION 2

SUMMARY

REPORT FOR CASE: c:\\frames\\shine\\nrgoat30 -----------------------------

FOR IMPACT ICON: hei14 THE HEALTH IMPACTS FILE FOR THIS CASE CONTAINS INFORMATION ON:

4 AGE GROUP(S) 6 RADIONUCLIDES (COUNTING DECAY PROGENY SEPARATELY IN CHAINS) 1 ORGAN(S)/TISSUE(S) FOR RADIATION DOSE 1 POTENTIAL CANCER SITES

SUMMARY

OF CASE INPUT DATA ---------------------------------------------------------------------------

SUMMARY

OF INPUT DATA FOR ATMOSPHERIC RELEASES -------------------------------------------------------

FOR LOCATION usr9 THE RELEASE IS Point EXIT AREA, M2: 1.00E-01 EXIT HEIGHT, M: 1.00E+01 HEIGHT OF ADJACENT BUILDING, M: 1.00E+01 EXIT VELOCITY, M/S: 0.00E+00 EXIT TEMPERATURE, DEGREE C: 9.30E+00 AMBIENT TEMPERATURE, DEGREE C; 9.30E+00 RELEASE MEDIUM 1 IS A GAS WITH NON-DEPOSITING FRACTION 5.00E-01 RELEASE PARTICLE 2 HAS RADIUS 3.00E+00 um RADIONUCLIDE TIME GAS PARTICLE 1 PARTICLE 2 PARTICLE 3 RELEASE RATE (yr) (pCi/yr) (pCi/yr) (pCi/yr) (pCi/yr)

AR41 0.00E+00 1.52E+13 0.00E+00 0.00E+00 0.00E+00 1.00E+00 1.52E+13 0.00E+00 0.00E+00 0.00E+00 I131 0.00E+00 6.65E+11 2.85E+11 0.00E+00 0.00E+00 1.00E+00 6.65E+11 2.85E+11 0.00E+00 0.00E+00 KR85 0.00E+00 1.20E+14 0.00E+00 0.00E+00 0.00E+00 1.00E+00 1.20E+14 0.00E+00 0.00E+00 0.00E+00 XE131m 0.00E+00 5.53E+14 0.00E+00 0.00E+00 0.00E+00 1.00E+00 5.53E+14 0.00E+00 0.00E+00 0.00E+00 XE133 0.00E+00 1.08E+16 0.00E+00 0.00E+00 0.00E+00 1.00E+00 1.08E+16 0.00E+00 0.00E+00 0.00E+00 XE133m 0.00E+00 4.08E+11 0.00E+00 0.00E+00 0.00E+00 1.00E+00 4.08E+11 0.00E+00 0.00E+00 0.00E+00

SUMMARY

OF ATMOSPHERIC TRANSPORT RESULTS FOR MODULE air10 ------------------

METEOROLOGICAL DATA TAKEN FROM FILE: NOT FOUND DISPERSION PARAMETERIZATION 0 data set was not found, NLINES =$__7 MINIMUM WIND SPEED DURING PLUME RISE 0.00 M/S SIGMA TO SHIFT TO SEMI-INFINITE CLOUD SHINE 0.00 M

Design Analyses and Calculation Page 111 of 125 Form Atkins-NS-EN-13-03 R3 TRANSFER RESISTENCE FOR IODINE 0.00 S/M TRANSFER RESISTENCE FOR PARTICLES 0.00 S/M MAXIMUM WIND SPEED FOR CALM 0.00 M/S

SUMMARY

OF INPUT DATA FOR EXPOSURE MODULE exp12 ------------------------

TERRESTRIAL ACCUMULATION TIME LINE:

START OF RELEASE (YEARS BEFORE INITIAL EXPOSURE): 15.

DURATION OF RELEASE (YEARS SINCE INITIAL RELEASE): 30.

DURATION OF EXPOSURE (YEARS): 1.

GENERAL ENVIRONMENTAL BEHAVIOR CONTROLS:

TYPE OF RESUSPENSION MODEL: None TYPE OF SOIL LEACHING MODEL: Calculated From User Input TYPE OF AIR SUBMERSION MODEL: Infinite Plume INADVERTANT SOIL INGESTION PATHWAY: ON ESTIMATION OF INDOOR AIR CONCENTRATIONS: ON ESTIMATION OF OUTDOOR SOIL EXTERNAL DOSE RATES: ON HARVEST REMOVAL OF CONTAMINANTS FROM SOIL: ON ABSOLUTE HUMIDITY FOR H-3 CALCULATIONS, KG/M3: 8.00E-03 FRACTION OF ROOTS IN SURFACE SOILS: 1.00E+00 SURFACE SOIL DENSITY, KG/M3: 1.60E+03 WEATHERING RATE HALF-TIME FOR VEGETATION, DAYS: 1.40E+01 AVERAGE RAINFALL RATE (WHEN RAINING), MM/DAY: 2.42E+00 RESUSPENSION FACTOR FOR SOIL-TO-PLANT, 1/M: 1.00E-09 LOCAL DEPOSITION VELOCITY FOR RESUSPENDED SOIL, M/S: 1.00E-03 SURFACE SOIL AREAL DENSITY, KG/M2: 2.40E+02 SURFACE SOIL LAYER THICKNESS, M: 1.50E+01 GROW STANDING YIELD INTAKE DRY-TO-WET TRANSLOCATION TIME BIOMASS (KG/M2) DELAY RATIO FACTOR TERRESTRIAL FOODS (DAYS) (KG/M2) (DAYS)

LEAFY VEG 60. 2.00 2.00 1.00 0.10 1.00 OTHER VEG 60. 2.00 2.00 60.00 0.20 0.10 FRUIT 60. 3.00 2.00 60.00 0.20 0.10 GRAIN 60. 1.60 2.00 60.00 0.88 0.10 GROW STANDING YIELD STORAGE DRY-TO-WET TRANSLOCATION DIET CONSUMPTION SOIL INTAKE TIME BIOMASS (KG/M2) TIME RATIO FACTOR FRACTION RATE INTAKE DELAY ANIMAL PRODUCTS (DAYS) (KG/M2) (DAYS) (KG/D) (KG/D) (DAYS)

STORED FEED MEAT 90. 1.60 0.80 90.00 0.88 0.10 1.00 17.00 1.00 20.00 POULTRY 90. 1.60 0.80 180.00 0.88 0.10 1.00 0.12 0.00 1.00 MILK 30. 1.00 0.70 90.00 0.20 1.00 1.00 1.50 1.00 1.00 EGGS 90. 1.60 0.80 180.00 0.88 0.10 1.00 0.12 0.00 1.00 FRESH FORAGE MEAT ANIMAL 45. 1.00 2.00 0.00 0.20 1.00 1.00 51.00 MILK COW 30. 1.50 0.70 0.00 0.20 1.00 1.00 4.50

SUMMARY

OF INPUT DATA FROM RECEPTOR MODULE rcp13 -------------------------

FOR AGE GROUP 1 THE LOWER AGE LIMIT IS 0.0 AND THE UPPER AGE LIMIT IS 1.0 YEARS.

Design Analyses and Calculation Page 112 of 125 Form Atkins-NS-EN-13-03 R3 FOR AGE GROUP 2 THE LOWER AGE LIMIT IS 1.0 AND THE UPPER AGE LIMIT IS 11.0 YEARS.

FOR AGE GROUP 3 THE LOWER AGE LIMIT IS 11.0 AND THE UPPER AGE LIMIT IS 17.0 YEARS.

FOR AGE GROUP 4 THE LOWER AGE LIMIT IS 17.0 AND THE UPPER AGE LIMIT IS 70.0 YEARS.

FOR AGE GROUP 1 DAILY PLUME IMMERSION EXPOSURE TIME IS 24.0 HOURS/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 2 DAILY PLUME IMMERSION EXPOSURE TIME IS 24.0 HOURS/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 DAILY PLUME IMMERSION EXPOSURE TIME IS 24.0 HOURS/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 DAILY PLUME IMMERSION EXPOSURE TIME IS 24.0 HOURS/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 DAILY SOIL EXTERNAL EXPOSURE TIME IS 24.0 HOURS/DAY FOR 182.5 DAYS/YEAR, WITH FRACTIONS OF TIME INDOORS/OUTDOORS OF 0.700/0.300 FOR AGE GROUP 2 DAILY SOIL EXTERNAL EXPOSURE TIME IS 24.0 HOURS/DAY FOR 182.5 DAYS/YEAR, WITH FRACTIONS OF TIME INDOORS/OUTDOORS OF 0.700/0.300 FOR AGE GROUP 3 DAILY SOIL EXTERNAL EXPOSURE TIME IS 24.0 HOURS/DAY FOR 182.5 DAYS/YEAR, WITH FRACTIONS OF TIME INDOORS/OUTDOORS OF 0.700/0.300 FOR AGE GROUP 4 DAILY SOIL EXTERNAL EXPOSURE TIME IS 24.0 HOURS/DAY FOR 182.5 DAYS/YEAR, WITH FRACTIONS OF TIME INDOORS/OUTDOORS OF 0.700/0.300 THE SHIELDING FACTORS FOR INDOOR AND OUTDOOR EXPOSURE ARE 0.700 AND 1.000 FOR AGE GROUP 1 CONSUMPTION OF LEAFY VEG IS 0.000 KG/DAY FOR 0.0 DAYS/YEAR FOR AGE GROUP 2 CONSUMPTION OF LEAFY VEG IS 0.071 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 CONSUMPTION OF LEAFY VEG IS 0.115 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 CONSUMPTION OF LEAFY VEG IS 0.148 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 CONSUMPTION OF OTHER VEG IS 0.000 KG/DAY FOR 0.0 DAYS/YEAR FOR AGE GROUP 2 CONSUMPTION OF OTHER VEG IS 0.769 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 CONSUMPTION OF OTHER VEG IS 0.931 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 CONSUMPTION OF OTHER VEG IS 0.769 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 CONSUMPTION OF FRUIT IS 0.000 KG/DAY FOR 0.0 DAYS/YEAR FOR AGE GROUP 2 CONSUMPTION OF FRUIT IS 0.313 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 CONSUMPTION OF FRUIT IS 0.379 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 CONSUMPTION OF FRUIT IS 0.313 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 CONSUMPTION OF GRAIN IS 0.000 KG/DAY FOR 0.0 DAYS/YEAR FOR AGE GROUP 2 CONSUMPTION OF GRAIN IS 0.342 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 CONSUMPTION OF GRAIN IS 0.414 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 CONSUMPTION OF GRAIN IS 0.342 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 CONSUMPTION OF MEAT IS 0.000 KG/DAY FOR 0.0 DAYS/YEAR FOR AGE GROUP 2 CONSUMPTION OF MEAT IS 0.112 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 CONSUMPTION OF MEAT IS 0.178 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 CONSUMPTION OF MEAT IS 0.301 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 CONSUMPTION OF POULTRY IS 0.000 KG/DAY FOR 0.0 DAYS/YEAR FOR AGE GROUP 2 CONSUMPTION OF POULTRY IS 0.049 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 CONSUMPTION OF POULTRY IS 0.049 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 CONSUMPTION OF POULTRY IS 0.049 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 CONSUMPTION OF MILK IS 0.904 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 2 CONSUMPTION OF MILK IS 0.900 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 CONSUMPTION OF MILK IS 1.100 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 CONSUMPTION OF MILK IS 0.840 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 CONSUMPTION OF EGGS IS 0.000 KG/DAY FOR 0.0 DAYS/YEAR FOR AGE GROUP 2 CONSUMPTION OF EGGS IS 0.032 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 CONSUMPTION OF EGGS IS 0.032 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 CONSUMPTION OF EGGS IS 0.032 KG/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 CONSUMPTION OF SOIL IS 1.00E+02 MILLIGRAMS/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 2 CONSUMPTION OF SOIL IS 1.00E+02 MILLIGRAMS/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 3 CONSUMPTION OF SOIL IS 1.00E+02 MILLIGRAMS/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 4 CONSUMPTION OF SOIL IS 1.00E+02 MILLIGRAMS/DAY FOR 365.0 DAYS/YEAR FOR AGE GROUP 1 OUTDOOR INHALATION RATE IS 3.83 M3/DAY FOR 365.0 DAYS/YEAR, WITH A FRACTION OF A DAY OUTDOORS OF 0.250 FOR AGE GROUP 2 OUTDOOR INHALATION RATE IS 10.13 M3/DAY FOR 365.0 DAYS/YEAR, WITH A FRACTION OF A DAY OUTDOORS OF 0.250 FOR AGE GROUP 3 OUTDOOR INHALATION RATE IS 21.90 M3/DAY FOR 365.0 DAYS/YEAR, WITH A FRACTION OF A DAY OUTDOORS OF 0.250 FOR AGE GROUP 4 OUTDOOR INHALATION RATE IS 21.90 M3/DAY FOR 365.0 DAYS/YEAR, WITH A FRACTION OF A DAY OUTDOORS OF 0.250 FOR AGE GROUP 1 INDOOR INHALATION RATE IS 3.83 M3/DAY FOR 365.0 DAYS/YEAR,

Design Analyses and Calculation Page 113 of 125 Form Atkins-NS-EN-13-03 R3 WITH A FRACTION OF A DAY INDOORS OF 0.750 FOR AGE GROUP 2 INDOOR INHALATION RATE IS 10.13 M3/DAY FOR 365.0 DAYS/YEAR, WITH A FRACTION OF A DAY INDOORS OF 0.750 FOR AGE GROUP 3 INDOOR INHALATION RATE IS 21.90 M3/DAY FOR 365.0 DAYS/YEAR, WITH A FRACTION OF A DAY INDOORS OF 0.750 FOR AGE GROUP 4 INDOOR INHALATION RATE IS 21.90 M3/DAY FOR 365.0 DAYS/YEAR, WITH A FRACTION OF A DAY INDOORS OF 0.750 ADDITIONAL NOTES:

Napier 2002 S&L 2012-03856 assumed 0 S&L 2012-03856 assumed exit height of 10 m.

Assumed equivalent to exit height of source Assumed 0 m/s consistent with S&L 2012-03856 Set equal to ambient temperature for non-heated release Assume average of average temperatures reported in PSAR Table 19.3.2-20 Reg Guide 1.109 stipulates 1 year duration Reg Guide 1-109 stipulates 1 year exposure Reg Guide 1.109 accumulation time + exposure time Reg Guide 1.109 stipulates 15 year accumulation Duration of release period set at lifetime of operating license per PSAR RG 1.109 Eq C-6: half the radioiodine emissions considered nonelemental.

Average from PSAR Tables 19.3.2-2 and 19.3.2-3 Reg Guide 1.109 Table E-15 Based on assumed values for areal density and surface soil layer thickness Reg Guide 1.109 Table E-15 Time Delay between harvest and ingestion Reg Guide 1.109 Table E-15 Agricultural productivity by unit area Reg Guide 1.109 Table E-15 Period of Growing Season Reg Guide 1.109 Table E-15 Agricultural Productivity Reg Guide 1.109 Table E-15 Time deal ingestion of crops by man Reg Guide 1.109 Table E-15 Ave time from slaughter of meat animal to consumption Reg Guide 1.109 TAble E-15 Attenuation Factor for shielding provided by residential structure Reg Guide 1.109 Table E-5 Infant Intake Reg Guide 1.109 Table E-5 Child Consumption Reg Guide 1.109 Table E-5 Teen Consumption Reg Guide 1.109 Table E-15 Adult Consumption Regulatory Guide 1.109 Table E-3 goat consumption rate 1 EXPOSURE PERIOD(S).

INDIVIDUAL DOSE CALCULATION ONLY, NO POPULATION TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

MAXIMUM POINT = 1 CORRESPONDING TO DIRECTION 1 AND DISTANCE 1 AT LOCATION X= 0.0 KM; Y= 0.0 KM INDIVIDUAL AGE RANGE 0 TO 1 YEARS MAXIMUM EXPOSED INDIVIDUAL LOCATION ORGAN MAX. DOSE (rem )

total body 5.09E-04 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

MAXIMUM LOCATION = 1 INDIVIDUAL EFFECTIVE DOSE AND RISK BY NUCLIDE NUCLIDE DOSE (rem ) CANCER INCIDENCE CANCER FATALITIES INDIVIDUAL AGE RANGE 0 TO 1 YEARS AR41 1.94E-05 0.00E+00 0.00E+00 I131 1.56E-04 0.00E+00 0.00E+00 KR85 2.79E-07 0.00E+00 0.00E+00 XE131m 4.22E-06 0.00E+00 0.00E+00 XE133 3.29E-04 0.00E+00 0.00E+00

Design Analyses and Calculation Page 114 of 125 Form Atkins-NS-EN-13-03 R3 XE133m 1.10E-08 0.00E+00 0.00E+00 EFFECTIVE DOSE (rem )BY RELEASE CATEGORY AT MAXIMUM INDIVIDUAL LOCATION:

TRITIUM (PLUS OBT) : 0.00E+00 CARBON-14 : 0.00E+00 NOBLE GASES : 3.53E-04 IODINE RADIONUCLIDES: 1.56E-04 PARTICULATE NUCLIDES: 0.00E+00 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

INDIVIDUAL AGE RANGE 0 TO 1 YEARS MAXIMUM LOCATION = 1 INDIVIDUAL EFFECTIVE DOSE AND RISK BY EXPOSURE PATHWAY PATHWAY ROUTE DOSE (rem ) CANCER INCIDENCE CANCER FATALITIES Air external 3.53E-04 0.00E+00 0.00E+00 Air inhalation 1.84E-06 0.00E+00 0.00E+00 Eggs ingestion 0.00E+00 0.00E+00 0.00E+00 Fruit ingestion 0.00E+00 0.00E+00 0.00E+00 Grain ingestion 0.00E+00 0.00E+00 0.00E+00 Ground external 1.35E-06 0.00E+00 0.00E+00 Indoor air inhalation 5.51E-06 0.00E+00 0.00E+00 Leafy vegetables ingestion 0.00E+00 0.00E+00 0.00E+00 Meat ingestion 0.00E+00 0.00E+00 0.00E+00 Milk ingestion 1.47E-04 0.00E+00 0.00E+00 Poultry ingestion 0.00E+00 0.00E+00 0.00E+00 Root vegetables ingestion 0.00E+00 0.00E+00 0.00E+00 Soil ingestion 6.31E-10 0.00E+00 0.00E+00 Soil inhalation 0.00E+00 0.00E+00 0.00E+00 INDIVIDUAL EFFECTIVE DOSE AND RISK BY PATHWAY BY RADIONUCLIDE INDIVIDUAL DOSE FOR PATHWAY: Air external DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 1.94E-05 5.49%

I131 3.39E-07 0.10%

KR85 2.79E-07 0.08%

XE131m 4.22E-06 1.19%

XE133 3.29E-04 93.14%

XE133m 1.10E-08 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Air inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.84E-06 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Eggs ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Fruit ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION

Design Analyses and Calculation Page 115 of 125 Form Atkins-NS-EN-13-03 R3 AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Grain ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Ground external DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.35E-06 99.94%

KR85 0.00E+00 0.00%

XE131m 7.46E-10 0.06%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Indoor air inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 5.51E-06 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Leafy vegetables ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Meat ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Milk ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.47E-04 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

Design Analyses and Calculation Page 116 of 125 Form Atkins-NS-EN-13-03 R3 INDIVIDUAL DOSE FOR PATHWAY: Poultry ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Root vegetables ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Soil ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 6.31E-10 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Soil inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

1 EXPOSURE PERIOD(S).

INDIVIDUAL DOSE CALCULATION ONLY, NO POPULATION TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

MAXIMUM POINT = 1 CORRESPONDING TO DIRECTION 1 AND DISTANCE 1 AT LOCATION X= 0.0 KM; Y= 0.0 KM INDIVIDUAL AGE RANGE 1 TO 11 YEARS MAXIMUM EXPOSED INDIVIDUAL LOCATION ORGAN MAX. DOSE (rem )

total body 5.55E-04 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

MAXIMUM LOCATION = 1 INDIVIDUAL EFFECTIVE DOSE AND RISK BY NUCLIDE NUCLIDE DOSE (rem ) CANCER INCIDENCE CANCER FATALITIES INDIVIDUAL AGE RANGE 1 TO 11 YEARS AR41 1.94E-05 0.00E+00 0.00E+00 I131 2.02E-04 0.00E+00 0.00E+00 KR85 2.79E-07 0.00E+00 0.00E+00 XE131m 4.22E-06 0.00E+00 0.00E+00 XE133 3.29E-04 0.00E+00 0.00E+00 XE133m 1.10E-08 0.00E+00 0.00E+00

Design Analyses and Calculation Page 117 of 125 Form Atkins-NS-EN-13-03 R3 EFFECTIVE DOSE (rem )BY RELEASE CATEGORY AT MAXIMUM INDIVIDUAL LOCATION:

TRITIUM (PLUS OBT) : 0.00E+00 CARBON-14 : 0.00E+00 NOBLE GASES : 3.53E-04 IODINE RADIONUCLIDES: 2.02E-04 PARTICULATE NUCLIDES: 0.00E+00 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

INDIVIDUAL AGE RANGE 1 TO 11 YEARS MAXIMUM LOCATION = 1 INDIVIDUAL EFFECTIVE DOSE AND RISK BY EXPOSURE PATHWAY PATHWAY ROUTE DOSE (rem ) CANCER INCIDENCE CANCER FATALITIES Air external 3.53E-04 0.00E+00 0.00E+00 Air inhalation 4.85E-06 0.00E+00 0.00E+00 Eggs ingestion 8.15E-10 0.00E+00 0.00E+00 Fruit ingestion 5.88E-08 0.00E+00 0.00E+00 Grain ingestion 1.21E-07 0.00E+00 0.00E+00 Ground external 1.35E-06 0.00E+00 0.00E+00 Indoor air inhalation 1.46E-05 0.00E+00 0.00E+00 Leafy vegetables ingestion 3.25E-05 0.00E+00 0.00E+00 Meat ingestion 2.94E-06 0.00E+00 0.00E+00 Milk ingestion 1.45E-04 0.00E+00 0.00E+00 Poultry ingestion 1.42E-11 0.00E+00 0.00E+00 Root vegetables ingestion 2.16E-07 0.00E+00 0.00E+00 Soil ingestion 6.31E-10 0.00E+00 0.00E+00 Soil inhalation 0.00E+00 0.00E+00 0.00E+00 INDIVIDUAL EFFECTIVE DOSE AND RISK BY PATHWAY BY RADIONUCLIDE INDIVIDUAL DOSE FOR PATHWAY: Air external DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 1.94E-05 5.49%

I131 3.39E-07 0.10%

KR85 2.79E-07 0.08%

XE131m 4.22E-06 1.19%

XE133 3.29E-04 93.14%

XE133m 1.10E-08 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Air inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 4.85E-06 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Eggs ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 8.15E-10 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Fruit ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 5.88E-08 100.00%

Design Analyses and Calculation Page 118 of 125 Form Atkins-NS-EN-13-03 R3 KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Grain ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.21E-07 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Ground external DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.35E-06 99.94%

KR85 0.00E+00 0.00%

XE131m 7.46E-10 0.06%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Indoor air inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.46E-05 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Leafy vegetables ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 3.25E-05 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Meat ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 2.94E-06 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Milk ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.45E-04 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Poultry ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION

Design Analyses and Calculation Page 119 of 125 Form Atkins-NS-EN-13-03 R3 AR41 0.00E+00 0.00%

I131 1.42E-11 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Root vegetables ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 2.16E-07 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Soil ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 6.31E-10 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Soil inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

1 EXPOSURE PERIOD(S).

INDIVIDUAL DOSE CALCULATION ONLY, NO POPULATION TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

MAXIMUM POINT = 1 CORRESPONDING TO DIRECTION 1 AND DISTANCE 1 AT LOCATION X= 0.0 KM; Y= 0.0 KM INDIVIDUAL AGE RANGE 11 TO 17 YEARS MAXIMUM EXPOSED INDIVIDUAL LOCATION ORGAN MAX. DOSE (rem )

total body 6.33E-04 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

MAXIMUM LOCATION = 1 INDIVIDUAL EFFECTIVE DOSE AND RISK BY NUCLIDE NUCLIDE DOSE (rem ) CANCER INCIDENCE CANCER FATALITIES INDIVIDUAL AGE RANGE 11 TO 17 YEARS AR41 1.94E-05 0.00E+00 0.00E+00 I131 2.80E-04 0.00E+00 0.00E+00 KR85 2.79E-07 0.00E+00 0.00E+00 XE131m 4.22E-06 0.00E+00 0.00E+00 XE133 3.29E-04 0.00E+00 0.00E+00 XE133m 1.10E-08 0.00E+00 0.00E+00 EFFECTIVE DOSE (rem )BY RELEASE CATEGORY AT MAXIMUM INDIVIDUAL LOCATION:

TRITIUM (PLUS OBT) : 0.00E+00

Design Analyses and Calculation Page 120 of 125 Form Atkins-NS-EN-13-03 R3 CARBON-14 : 0.00E+00 NOBLE GASES : 3.53E-04 IODINE RADIONUCLIDES: 2.80E-04 PARTICULATE NUCLIDES: 0.00E+00 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

INDIVIDUAL AGE RANGE 11 TO 17 YEARS MAXIMUM LOCATION = 1 INDIVIDUAL EFFECTIVE DOSE AND RISK BY EXPOSURE PATHWAY PATHWAY ROUTE DOSE (rem ) CANCER INCIDENCE CANCER FATALITIES Air external 3.53E-04 0.00E+00 0.00E+00 Air inhalation 1.05E-05 0.00E+00 0.00E+00 Eggs ingestion 8.15E-10 0.00E+00 0.00E+00 Fruit ingestion 7.11E-08 0.00E+00 0.00E+00 Grain ingestion 1.45E-07 0.00E+00 0.00E+00 Ground external 1.35E-06 0.00E+00 0.00E+00 Indoor air inhalation 3.15E-05 0.00E+00 0.00E+00 Leafy vegetables ingestion 5.26E-05 0.00E+00 0.00E+00 Meat ingestion 4.65E-06 0.00E+00 0.00E+00 Milk ingestion 1.79E-04 0.00E+00 0.00E+00 Poultry ingestion 1.42E-11 0.00E+00 0.00E+00 Root vegetables ingestion 2.62E-07 0.00E+00 0.00E+00 Soil ingestion 6.31E-10 0.00E+00 0.00E+00 Soil inhalation 0.00E+00 0.00E+00 0.00E+00 INDIVIDUAL EFFECTIVE DOSE AND RISK BY PATHWAY BY RADIONUCLIDE INDIVIDUAL DOSE FOR PATHWAY: Air external DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 1.94E-05 5.49%

I131 3.39E-07 0.10%

KR85 2.79E-07 0.08%

XE131m 4.22E-06 1.19%

XE133 3.29E-04 93.14%

XE133m 1.10E-08 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Air inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.05E-05 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Eggs ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 8.15E-10 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Fruit ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 7.11E-08 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

Design Analyses and Calculation Page 121 of 125 Form Atkins-NS-EN-13-03 R3 XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Grain ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.45E-07 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Ground external DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.35E-06 99.94%

KR85 0.00E+00 0.00%

XE131m 7.46E-10 0.06%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Indoor air inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 3.15E-05 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Leafy vegetables ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 5.26E-05 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Meat ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 4.65E-06 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Milk ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.79E-04 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Poultry ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.42E-11 100.00%

Design Analyses and Calculation Page 122 of 125 Form Atkins-NS-EN-13-03 R3 KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Root vegetables ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 2.62E-07 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Soil ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 6.31E-10 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Soil inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

1 EXPOSURE PERIOD(S).

INDIVIDUAL DOSE CALCULATION ONLY, NO POPULATION TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

MAXIMUM POINT = 1 CORRESPONDING TO DIRECTION 1 AND DISTANCE 1 AT LOCATION X= 0.0 KM; Y= 0.0 KM INDIVIDUAL AGE RANGE 17 TO 70 YEARS MAXIMUM EXPOSED INDIVIDUAL LOCATION ORGAN MAX. DOSE (rem )

total body 6.08E-04 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

MAXIMUM LOCATION = 1 INDIVIDUAL EFFECTIVE DOSE AND RISK BY NUCLIDE NUCLIDE DOSE (rem ) CANCER INCIDENCE CANCER FATALITIES INDIVIDUAL AGE RANGE 17 TO 70 YEARS AR41 1.94E-05 0.00E+00 0.00E+00 I131 2.55E-04 0.00E+00 0.00E+00 KR85 2.79E-07 0.00E+00 0.00E+00 XE131m 4.22E-06 0.00E+00 0.00E+00 XE133 3.29E-04 0.00E+00 0.00E+00 XE133m 1.10E-08 0.00E+00 0.00E+00 EFFECTIVE DOSE (rem )BY RELEASE CATEGORY AT MAXIMUM INDIVIDUAL LOCATION:

TRITIUM (PLUS OBT) : 0.00E+00 CARBON-14 : 0.00E+00 NOBLE GASES : 3.53E-04

Design Analyses and Calculation Page 123 of 125 Form Atkins-NS-EN-13-03 R3 IODINE RADIONUCLIDES: 2.55E-04 PARTICULATE NUCLIDES: 0.00E+00 TIME PERIOD NUMBER 1, CORRESPONDING TO TIME 15.0000 YEARS ------------------------------------------------

INDIVIDUAL AGE RANGE 17 TO 70 YEARS MAXIMUM LOCATION = 1 INDIVIDUAL EFFECTIVE DOSE AND RISK BY EXPOSURE PATHWAY PATHWAY ROUTE DOSE (rem ) CANCER INCIDENCE CANCER FATALITIES Air external 3.53E-04 0.00E+00 0.00E+00 Air inhalation 1.05E-05 0.00E+00 0.00E+00 Eggs ingestion 8.15E-10 0.00E+00 0.00E+00 Fruit ingestion 5.88E-08 0.00E+00 0.00E+00 Grain ingestion 1.21E-07 0.00E+00 0.00E+00 Ground external 1.35E-06 0.00E+00 0.00E+00 Indoor air inhalation 3.15E-05 0.00E+00 0.00E+00 Leafy vegetables ingestion 6.75E-05 0.00E+00 0.00E+00 Meat ingestion 7.88E-06 0.00E+00 0.00E+00 Milk ingestion 1.36E-04 0.00E+00 0.00E+00 Poultry ingestion 1.42E-11 0.00E+00 0.00E+00 Root vegetables ingestion 2.16E-07 0.00E+00 0.00E+00 Soil ingestion 6.31E-10 0.00E+00 0.00E+00 Soil inhalation 0.00E+00 0.00E+00 0.00E+00 INDIVIDUAL EFFECTIVE DOSE AND RISK BY PATHWAY BY RADIONUCLIDE INDIVIDUAL DOSE FOR PATHWAY: Air external DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 1.94E-05 5.49%

I131 3.39E-07 0.10%

KR85 2.79E-07 0.08%

XE131m 4.22E-06 1.19%

XE133 3.29E-04 93.14%

XE133m 1.10E-08 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Air inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.05E-05 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Eggs ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 8.15E-10 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Fruit ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 5.88E-08 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

Design Analyses and Calculation Page 124 of 125 Form Atkins-NS-EN-13-03 R3 INDIVIDUAL DOSE FOR PATHWAY: Grain ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.21E-07 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Ground external DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.35E-06 99.94%

KR85 0.00E+00 0.00%

XE131m 7.46E-10 0.06%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Indoor air inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 3.15E-05 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Leafy vegetables ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 6.75E-05 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Meat ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 7.88E-06 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Milk ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.36E-04 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Poultry ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 1.42E-11 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

Design Analyses and Calculation Page 125 of 125 Form Atkins-NS-EN-13-03 R3 XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Root vegetables ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 2.16E-07 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Soil ingestion DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 6.31E-10 100.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%

INDIVIDUAL DOSE FOR PATHWAY: Soil inhalation DOSE (rem ) INCIDENCE FATALITIES CONTRIBUTION AR41 0.00E+00 0.00%

I131 0.00E+00 0.00%

KR85 0.00E+00 0.00%

XE131m 0.00E+00 0.00%

XE133 0.00E+00 0.00%

XE133m 0.00E+00 0.00%