Initial Exam 2015-301 Final Administrative JPMs
ML15079A128
Person / Time
Site: Browns Ferry  
(DPR-033, DPR-052, DPR-068)
Issue date: 03/20/2015
From:
NRC/RGN-II
To:
Tennessee Valley Authority
Shared Package
ML15079A140 List:
References
50-259/15-301, 50-260/15-301, 50-296/15-301
Download: ML15079A128 (108)


Text

{{#Wiki_filter:liml Job Performance Measure (JPM) SITE: I BFN JPM TITLE: Work Hour Limitations - RO Only JPM NUMBER: 551 REVISION: I 2 TASKAPPLICABILITY: I DSRO I DSTA I

  • uo I

DNAUO TASK NUMBER I TASK TITLE(S): I KIA RATINGS: I RO 2.9* SRO 3.9 KIA STATEMENT:, 2. ! -~Ability to use procedures rel~ted ~o ~hi~ staffing, such as m1mmum crew complement, overtime llm1tat1ons, etc. RELATED PRA INFORMATION: I N/A SAFETY FUNCTION: I Admin - Conduct of Operations EVALUATION LOCATION: D In-Plant D Simulator ID Control Room I D Lab

  • Other-Classroom List APPLICABLE METHOD OF TESTING: 0 Discussion 0Simulate/Walkthrough *Perform TIME FOR COMPLETION:_N_IA ___ TIME CRITICAL (Y/N) N ALTERNATE PATH (YIN) N Developed by:

Developer Date (Ensure validator is briefed on exam security per NPG-SPP-17.8.1) (See JPM Validation Checklist in NPG-SPP-17.8.2) Validated by: Validator Date Approved by: Site Training Management Date Approved by: Site Training Program Owner Date 1

I ID]I Job Performance Measure (JPM) OPERATOR: JPM Number 551 RO DATE: __ TASK STANDARD: Evaluates Schedule and determines that the work hour limit requiring a continuous break of at least 34 hours in any 9 day period is not met. Determines that the schedule needs to be revised or a waiver granted IAW NPG-SPP-03.21. PRA: NA REFERENCES/PROCEDURES NEEDED: NPG-SPP-03.21, Fatigue Management and Work Hour Limits VALIDATION TIME: 15 Minutes PERFORMANCE TIME: __ COMMENTS: ------------------------- Additional comment sheets attached? YES NO RESULTS: SATISFACTORY UNSATISFACTORY SIGNATURE: __________ DATE: ___ EXAMINER 2 (Retain entire JPM for records)

I mill Job Performance Measure (JPM) INITIAL CONDITIONS: You are a Reactor Operator. Unit 1 is operating at 100%, Unit 3 is coming out of a Refuel Outage and startup is planned for tomorrow. Unit 2 has just pulled critical after a forced outage. You were on Annual Leave Friday 11/07 and Saturday 11/08 but were called in today 11/09 to support the U2 Startup. You were in compliance with all work hour limits during your last shift cycle. Below is your proposed work schedule for the 5 week shift cycle starting today. You are assigned to Unit 2 for this shift cycle. Assume that you will arrive 30 minutes prior to the start of your shift for shift turnover each work day. The eSOMS NFR program is not available. INITIATING CUES: Review the proposed work schedule to verify all work hour limits will be met. If any limits are not met, then identify what administrative measures are required. 3

I UEI Job Performance Measure (JPM) START TIME STEP/STANDARD Step 1: Applicant reviews proposed schedule against 1 OCFR26 limits. 3.2 Requirements 3.2.1 10 Code of Federal Regulations (CFR) 26 Overtime Limits [R.21] A The following limits apply to covered individuals regardless of unit status [R.22, 23]:

1. No more than 16 work hours in any 24 hour period
2. No more than 26 work hours in any 48 hour period
3. No more than 72 work hours in any 7 day (168 hour) period
4. At least a 10 hour break between successive work periods.
5. A continuous break of at least 34 hours in any 9 day (216 hour) period.

B. Online Requirements [R.24] I. During on line operations and without issuance of a waiver, an individual's required average minimum days off shall adhere to the requirements listed in Table 1 below (averaged over the shift cycle): Table 1. Required Average Minimum Days Off (MOO) for Various Shift Cycle Schedules Group 8 Hour Shift 10 Hour Shift 12 Hour Shift Maintenance 'I day off/weelc 2 days -0ff/wee1< 2 days off/week Operations, Radiation Protection, 1 day off/week 2 days off/week 2.5 days off/week Chemistry, Fire Brigade (Incident Commander) Security f 1 day off/week 2 days off/week 3 days off/week

2. For the purposes of calculating an average number of days off, the duration of the shift cycle may not exceed six weeks nor be less than one week.
3. Online rules will be applied for a shift when any portion of the shift where the unit is defined to be online.

4 SAT/ UNSAT Critical Step SAT UNSAT N/A

llml Job Performance Measure (JPM) STEP/STANDARD SAT/ UNSAT Step 1 Standard: Evaluates schedule and determines that only the work hour limit requiring a continuous break of at least 34 hours in any 9 day period is not met. Step 2: Critical Step Applicant determines required actions. SAT Standard: UNSAT Determines that the schedule needs to be revised or a waiver granted. NIA STOP TIME --- END OF TASK 5

I ii!D I Job Performance Measure (JPM) Provide to Applicant INITIAL CONDITIONS: You are a Reactor Operator. Unit 1 is operating at 100%, Unit 3 is coming out of a Refuel Outage and startup is planned for tomorrow. Unit 2 has just pulled critical after a forced outage. You were on Annual Leave Friday 11/07 and Saturday 11/08 but were called in today 11/09 to support the U2 Startup. You were in compliance with all work hour limits during your last shift cycle. Below is your proposed work schedule for the 5 week shift cycle starting today. You are assigned to Unit 2 for this shift cycle. Assume that you will arrive 30 minutes prior to the start of your shift for shift turnover each work day. The eSOMS NFR program is not available. INITIATING CUES: Review the proposed work schedule to verify all work hour limits will be met. If any limits are not met, then identify what administrative measures are required. 6

I U!ll Job Performance Measure (JPM) SITE: I BFN JPM TITLE: Work Hour Limitations - SRO Only JPM NUMBER: 641 REVISION: I 1 TASKAPPLICABILITY: J

  • SRO I

DSTA I DUO I DNAUO TASK NUMBER I TASK TITLE(S): I KIA RATINGS: I RO 2.9* SRO 3.9 KIA STATEMENT:, 2. ~.~Ability to use procedures rel~ted ~o ~hi~ staffing, such as m1mmum crew complement, overtime llm1tat1ons, etc. RELATED PRA INFORMATION: I N/A SAFETY FUNCTION: J Admin - Conduct of Operations EVALUATION LOCATION: Din-Plant D Simulator ID Control Room I D Lab

  • Other-Classroom List APPLICABLE METHOD OF TESTING: 0 Discussion 0Simulate/Walkthrough *Perform TIME FOR COMPLETION:_N_IA ___ TIME CRITICAL (Y/N) N ALTERNATE PATH (Y/N) N Developed by:

Developer Date (Ensure validator is briefed on exam security per NPG-SPP-17.8.1) (See JPM Validation Checklist in NPG-SPP-17.8.2) Validated by: Validator Date Approved by: Site Training Management Date Approved by: Site Training Program Owner Date 1

I IIEI Job Performance Measure (JPM) OPERATOR: JPM Number 641 RO DATE: --- TASK STANDARD: Evaluates Schedule and determines that the work hour limit requiring a continuous break of at least 34 hours in any 9 day period is not met. Determines that the schedule needs to be revised or a waiver granted IAW NPG-SPP-03.21. PRA: NA REFERENCES/PROCEDURES NEEDED: NPG-SPP-03.21, Fatigue Management and Work Hour Limits VALIDATION TIME: 20 Minutes PERFORMANCE TIME: __ COMMENTS: ------------------------- Additional comment sheets attached? YES NO RESULTS: SATISFACTORY UNSATISFACTORY SIGNATURE: DATE: EXAMINER 2 (Retain entire JPM for records)

I U!ll Job Performance Measure (JPM) INITIAL CONDITIONS: You are a Senior Reactor Operator. Unit 1 is operating at 100%, Unit 3 is coming out of a Refuel Outage and startup is planned for tomorrow. Unit 2 has just pulled critical after a forced outage. The BOP operator was on Annual Leave Friday 11 /07 and Saturday 11 /08 but was called in today 11/09 to support the U2 Startup. He was in compliance with all work hour limits during his last shift cycle. Below is his proposed work schedule for the 5 week shift cycle starting today. He will be assigned to Unit 2 for this shift cycle. Assume that he will arrive 30 minutes prior to the start of his shift for shift turnover each work day. The eSOMS NFR program is not available. INITIATING CUES: Review the proposed work schedule to verify all work hour limits will be met. If any limits are not met, then identify what administrative measures are required. 3

llml Job Performance Measure (JPM) START TIME STEP/STANDARD Step 1: Applicant reviews proposed schedule against 1 OCFR26 limits 3.2 Requirements 3.2.1 10 Code of Federal Regulations (CFR) 26 Overtime Limits [R.21] A. The following limits apply to covered individuals regardless of unit status [R.22, 23]:

1. No more than 16 work hours in any 24 hour period
2. No more than 26 work hours in any 48 hour period
3. No more than 72 work hours in any 7 day (168 hour) period
4. At least a 10 hour break between successive work periods.
5. A continuous break of at least 34 hours in any 9 day (216 hour) period.

B. Online Requirements [R.24]

1. During online operations and without issuance of a waiver, an individual's required average minimum days off shall adhere to the requirements listed in Table 1 below (averaged over the shift cycle):

Table 1. Required Average Minimum Days Off (MOO) for Various Shift Cycle Schedules Group 8 Hour Shift 10 Hour Shift 12 Hour Shift Maintenance 1 day off/week 2 days -0fflweel< 2 days off/week Operations, Radiation Protection, Chemistry, Fire Brigade (Incident Commander) 1 day off/week 2 days-0ff/week 2.5 days off/week Security 1 day off/week 2 days -0fflweek 3 days off/week

2. For the purposes of calculating an average number of days off, the duration of the shift cycle may not exceed six weeks nor be less than one week.
3. Online rules will be applied for a shift when any portion of the shift where the unit is defined to be online.

4 SAT/ UNSAT Critical Step SAT UNSAT NIA

I n!DI Job Performance Measure (JPM) STEP/STANDARD Step 1 Standard: Step 2: Evaluates Schedule and determines that only the work hour limit requiring a continuous break of at least 34 hours in any 9 day period is not met. Applicant determines required actions. Standard: Determines that the schedule needs to be revised or a waiver granted. Step 3: Applicant reviews NPG-SPP-03.21 and determines the required actions and authorizing authority. Standard: Determines that a 10CFR26 Overtime Limits Waiver (attachment 2) and A Fatigue Assessment (attachment 1) must be performed prior to Exceeding overtime limits and that the Site Vice President (SVP) or Senior-level manager with SVP signature authority must approve the Waiver. STOP TIME --- END OF TASK 5 SAT/ UNSAT Critical Step SAT UNSAT N/A Critical Step SAT UNSAT N/A

Job Performance Measure (JPM) Provide to Applicant INITIAL CONDITIONS: You are a Senior Reactor Operator. Unit 1 is operating at 100%, Unit 3 is coming out of a Refuel Outage and startup is planned for tomorrow. Unit 2 has just pulled critical after a forced outage. The BOP operator was on Annual Leave Friday 11 /07 and Saturday 11 /08 but was called in today 11 /09 to support the U2 Startup. He was in compliance with all work hour limits during his last shift cycle. Below is his proposed work schedule for the 5 week shift cycle starting today. He will be assigned to Unit 2 for this shift cycle. Assume that he will arrive 30 minutes prior to the start of his shift for shift turnover each workday. The eSOMS NFR program is not available. 11/09 11/12 0700-1900 1900-0700 12/06 1900-0700 INITIATING CUES: Review the proposed work schedule to verify all work hour limits will be met. If any limits are not met, then identify what administrative measures are required. 6

liml Job Performance Measure (JPM) SITE: BFN JPM TITLE: 3-SR-3.4.9.3&4 Reactor Recirculation Pump Start Limitations JPM NUMBER: 639 REVISION: I 0 TASK APPLICABILITY: I

  • SRO I

OSTA I

  • uo I

DNAUO TASK NUMBER / TASK TITLE(S): I U-068-.S~-O~ I Perform Reactor Recirculation Pump Start L1m1tations SI KIA RATINGS: 12.1.20 R04.6 SR04.6 KIA STATEMENT: I Ability to interpret and execute procedure steps RELATED PRA INFORMATION: I N/A SAFETY FUNCTION: / Admin - Conduct of Operations EVALUATION LOCATION: Din-Plant D Simulator ID Control Room I D Lab

  • Other - List Classroom APPLICABLE METHOD OF TESTING: 0 Discussion 0Simulate/Walkthrough
  • Perform TIME FOR COMPLETION:_N_IA ___ TIME CRITICAL (Y/N) N ALTERNATE PATH (Y/N) N Developed by:

Developer Date (Ensure validator is briefed on exam security per NPG-SPP-17.8.1) (See JPM Validation Checklist in NPG-SPP-17.8.2) Validated by: Validator Date Approved by: Site Training Management Date Approved by: Site Training Program Owner Date 1

I II!l I Job Performance Measure (JPM) OPERATOR: JPM Number 639 RO SRO DATE: --- TASK STANDARD: Upon performing 3-SR-3.4.9.3&4, determine that Recirculation Pump 3A can be started and that Recirculation Pump 38 can NOT be started PRA: NA REFERENCES/PROCEDURES NEEDED: 3-SR-3.4.9.3&4 Reactor Recirculation Pump Start Limitations and STS Sheet attached. VALIDATION TIME: 15 Minutes PERFORMANCE TIME: COMMENTS: ------------------------ Additional comment sheets attached? YES NO RESULTS: SATISFACTORY UNSATISFACTORY SIGNATURE: __________ DATE: ___ EXAMINER 2 (Retain entire JPM for records)

I lllll Job Performance Measure (JPM) INITIAL CONDITIONS: You are the Unit 3 Unit Operator. Unit 3 is in Mode 4 preparing for startup. Forced reactor coolant circulation has been lost. It is required to restore forced circulation. RWCU is in service. INITIATING CUE: Perform 3-SR-3.4.9.3&4 Reactor Recirculation Pump Start Limitations. 3

I ll!D I Job Performance Measure (JPM) KEY Table 1 (Page 1of1) R t R. I f P Start L. "taf D ta eac or ec1rcu a ion ump 1m1 ions a STEP PARAMETER Panel NO. INSTRUMENT OR COMPUTER LOG UNITS NO. 7.0[3] Recirc Loop A Temp. Computer 68-6A, Recirc Pmp A Suet Temp OR Computer 68-68, Recirc Pmp A Suet Temp OR Computer 68-2, Recirc Pmp A Discharge Temp OR 3-9-4 3-XR-68-2/5, 3-TE-68-2 (Point 003) 172.2or164.4°F RED-Pump A Recirc Loop B Temp. Computer 68-83A, Recirc Pmp B Suet Temp OR Computer 68-838, Recirc Pmp B Suet Temp OR Computer 68-78, Recirc Pmp B Discharge Temp OR 3-9-4 3-XR-68-2/5, 3-TE-68-78 (Point 004) 160or151.8 °F GRN-Pump B 7.0[4] Reactor Steam 3-9-5 3-Pl-3-54, Press A Dome Press. OR 3-9-5 3-Pl-3-61, Press B OR _O_psig Computer 3-54, Reactor Press 7.0[5] RPV Coolant Temp. As DETERMINED in Step 7.0[5] 212 OF 7.0[6] Reactor Bottom Head Drain Temp. As DETERMINED in Step 7.0[6] 123.2 OF 7.0[7] Dome/Drain !::::.. T AND ~145°F) Step (7.0[5] - 7.0[6]) 88.8 °F(AC) 7.0[8] Dome/Loop !::::.. T 39.8 or 47.6 °F(AC) 7.0[9] _:s50°F AND [In Mode 2 with Step (7.0[5] - 7.0[3]) Loop A 7.0[10] BOTH pumps NOT 52 or 60.2 °F(AC) in operation ~75°F)] Loop B NOTE Where applicable circle the instrument used. May N/A EITHER loop that is NOT being started. 4

I U!1 I Job Performance Measure (JPM) START TIME STEP/STANDARD Step 1: 7.0 PROCEDURE STEPS NOTE Notification of the US AND UO upon start AND finish of this SR is NOT required since it involves only data recording AND calculations. [1] VERIFY that the following initial conditions are satisfied: [1.1] VERIFY ALL precautions AND limitations in Section 3.0 have been reviewed. [1.2] VERIFY ALL prerequisites listed in Section 4.0 are satisfied. Standard: Reviews P&L's in Section 3.0 Verifies all prerequisites in section 4.0 are satisfied. Step 2: [2] RECORD the start date AND time started, reason for test, plant conditions, AND ANY pre-test remarks on the Surveillance Task Sheet (STS). Standard: Records the start date, time started on the STS. 5 SAT/UNSAT _SAT _UNSAT _N/A _SAT _UNSAT _N/A

I Im I Job Performance Measure (JPM) STEP/STANDARD Step 3: NOTE The following steps are required to be completed within 15 minutes of starting a recirc pump. On occasions where RWCU is out of service, the Bottom Head Drain temperature is required to be obtained using a Contact Pyrometer (Step 7.0(6.2.2]). This is required to be coordinated in advance AND the data taker is required to be in place SAT/UNSAT AND ready to record the temperature prior to continuing with Step 7.0[3]. Critical Step [3] RECORD Recirc Loop temperature(s) in Table 1 AND RECORD the time the Recirc Loop temperature(s) data was taken (IF applicable, THEN N/A the loop temperature for the loop NOT being started). Record time ---- Standard: Step 4: Records the recirc loop 3A temperature of 172.2 °F and/or 164.4°F in table 1, records recirc loop 38 temperature of 160 °F and/or 151.8°F and records current time. [4] RECORD Reactor Steam Dome pressure in Table 1. Standard: Records Reactor Steam Dome Pressure of 0 psig in Table 1. Step 5: [5] DETERMINE Reactor Coolant temperature as follows using the first step that satisfies its conditional requirement: (N/A the steps NOT used.): [5.1] If the Reactor Coolant System is producing steam, (in a saturated steam condition. Standard: Step 5.1 is NA 6 _SAT _UNSAT _N/A Critical Step _SAT _UNSAT _N/A _SAT _UNSAT _N/A

I U!lJ I Job Performance Measure (JPM) STEP/STANDARD SAT /UNSAT Step 6: [5.2] IF one Recirculation Loop is in operation AND the reactor is SAT NOT in Mode 1, THEN UNSAT Standard: N/A Step is N/A. Step 7: SAT [5.3] IF Shutdown Cooling is in service, THEN UNSAT Standard: N/A Step is N/A. Step 8: Critical Step [5.4] IF the reactor is in cold shutdown at zero pressure with NO forced circulation, THEN RECORD 212°F in Table 1. SAT Standard: UNSAT Records 212°F in Table 1. N/A Step 9: [6] DETERMINE Reactor Bottom Head Drain temperature as follows using EITHER step that satisfies its conditional requirement (NIA the step NOT used): Critical Step [6.1] IF RWCU is in service, THEN RECORD 3-TR-56-4, Point 7 (3-TE-56-8) OR RECORD Integrated Computer System SAT (ICS) Point 56-8 as the bottom Head Drain temperature in Table 1. UNSAT Standard: N/A Records Bottom Head Drain temperature of 123.2°F in Table 1 using the Integrated Computer System (ICS) Point 56-8. 7

I U!lil I Job Performance Measure (JPM) STEP/STANOARD SAT/UNSAT Step 10: [6.2] IF RWCU is out of service, or Step [6.1] cannot be SAT performed, THEN PERFORM the following (OTHERWISE, N/A): UNSAT Standard: N/A Step is N/A. Step 11: [7] CALCULATE the difference between Bottom Head Coolant Critical Step temperature AND the RPV Coolant Temperature by SUBTRACTING Reactor Bottom Head Drain temperature from SAT RPV coolant temperature AND RECORD this value in Table 1. Standard: UNSAT Subtracts 123.2°F from 212°F and records 88.8°F in Table 1. N/A Step 12: [8] VERIFY the difference between the Bottom Head Coolant Critical Step temperature AND the RPV Coolant temperature is S145°F, AND RECORD the time of verification. SAT Record time UNSAT Standard: N/A Verifies the temperature difference is less than 145°F. 8

I UEI Job Performance Measure (JPM) STEP/STANDARD SAT/UNSAT Step 13: [9] CALCULATE the difference between the Coolant temperature in the Recirculation Loop to be started AND the RPV Coolant temperature by SUBTRACTING the Recirculation Loop to be Critical Step started from the RPV Coolant temperature AND RECORD this value in Table 1. (N/A the other loop on occasions where only SAT one loop is being started). Standard: UNSAT Subtracts recirc loop 3A temperature of either 172.2°F or 164.4°F N/A from 212°F and records 39.8°F or 47.6°F for Loop A and then subtracts loop 38 temperature of either 160°F or 151.8°F from 212°F and records 52°F or 60.2°F for Loop B. Step 14: [10] VERIFY the difference between the Coolant temperature in the Recirculation Loop to be started the AND the RPV Coolant is Critical Step S50°F. OR In Mode 2 AND Both Recirc Pumps are NOT in operation, the difference may be S75°F. SAT Standard: UNSAT Determines that the 3A recirc pump can be started (< 50°F /1 N/A Temp) and that the 38 recirc pump can NOT be started{> 50°F /1 Temp). STOP TIME __ END OF TASK 9

I rnil I Job Performance Measure (JPM) Provide to Applicant INITIAL CONDITIONS: You are the Unit 3 Unit Operator. Unit 3 is in Mode 4 preparing for startup. Forced reactor coolant circulation has been lost. It is required to restore forced circulation. RWCU is in service. INITIATING CUE: Perform 3-SR-3.4.9.3&4 Reactor Recirculation Pump Start Limitations. 10

I II!l I Job Performance Measure (JPM) Provide to Applicant SURVEILLANCE TASK SHEET (STS) Wor1< Order#: Page1 1 of 1 PM#: P04284 Procedure: 3-SR-3.4.9.3&4

Title:

Rx Recirc Pumo Start Limitations Data Sheets Attached: No SelliM tJfJe'tatM Today Now Perf Grp: Ooerations Authorization to Begin: SRO Date Time Unit: 3 Loop/Div: Both Test Reason: Recirc Pumo Start Due Date: Todav Start Date & Time Completion Date & Time Frequency:; See Comments below Tech Spec: ASMEXI: Applicable Modes: Was this a complete or partial Perf Modes: perfomiance? Clearance Required: (Explain "Partial" in Remar1<s) Complete !&I Partial D EQ: Were all Tech Spec I Tech Req LCO Entered: / ISFSI Coe I ODCM I Fire Dry-Cask Storage: Protection Req I AMSAC acceptance criteria satisfied? YesD No D N/A D Were all other acceptance Criteria satisfied? YesD No D N/A D Perfomied By Print Name Sianature Initial Section If all Tech Spec /Tech Req YesD No D N/A D / ISFSI Coe I ODCM I Fire Protection Req I AMSAC criteria were not satisfied, was an LCO /TR I ODCM I OR action required? (Explain in Remar1<s) Service Request#: Alert Wor1< Control Required? D

  • PWRonly Subsequent Reviews:

Group: Siqnature Date Copy of STS sent to Wor1< Control I (next business day) Initials Date Test Coard/Lead Date PERMANENT COMMENTS: Acceptance Criteria Review: SRO Date Time Required once within 15 minutes prior to each start up of the Independent Reviewer Date Time Recirc Pumps. REMARKS: TVA40753 Page 1 of4 NPG-SPP-06.9.2-1 [06-14-13] 11

[fi!I-- --- ----------- J~bPerl;;~Measure(JPM) I GROUP DISPLAY FOR @3493.&4 RECIRC: PUMP STMT LIMITATIONS PID 3, 54 3-61 CALC046 56-8 CALC074 68-2 68-78 CAl.£080 CALC081 68*6.A 68-68 68-83A 68-838 CALC293 CALC294

CALC295, CALC2'96 QUAL VALUE 0

LOLO 0 .4 LOLO 151.8 LOLO 172.2 LOLO 172.2 LOLO 160. LOLO 160.0 Provide to Applicant UNITS PSIG PSIG DEG F DEG F DEG F DEG F DEG F DEG F DEG F DEG F DEG F DEG F DEG F DEG F DEG F DEG F DEG F Today's Date and Time Page l of 2 Update ra.te

l. o seooods DESCRIPTION RX PRESSURE-WIDE RANGE RX PRESSURE-WIDE RANGE IRX STE.AH TEMP (IF PRESS>10 PS IG)

REACTOR VESSEL DRAIN TO RWOJ RX DOHE TO BOTT<>I ffEPD DELTA-T RECIRC PMP A DISCHARGE TEMP 'l't' RECIRC PMP B DISCHAllGE TEMP RX 0Clt1E TO RECIRC A OSCH DELTA-T RX DOHE TO RECIRC B DSCH OELTA-T iREC IRC PHP A_ SUCT TEHP ( l OF 2) RECIRC PHP A SUCT TEMP (2 OF 2) RECIRC PHP B SUCT TEHP (1 OIF 2) RECIRC PHP B SUCT TEHP (2 OF 2) RX DOME TO REC A SUCT DEL TA-T 1. RX OOOE TO REC A SUCT DEL TA.-T 2 RX DOOE TO REC B SUCT DEL TA-T l RX OOOE TO REC B SUCT DEL TA-T.2 12

SURVEILLANCE TASK SHEET (STS) Work Order#: Page1 1 of 1 PM#: P04284 Procedure: 3-SR-3.4.9.3&4

Title:

Rx Recirc Pumo Start Limitations Data Sheets Attached: No Se<<UnO~ Today Now Perf Grp: Ooerations Authorization to Begin: SRO Date Time Unit: 3 Loop/Div: Both Test Reason: Due Date: Start Date & Time Completion Date & Time Frequency:; Tech Spec: ASMEXI: Applicable Modes: Was this a complete or partial Perf Modes: performance? Clearance Required: (Explain "Partial" in Remarks) Complete (g] Partial D EQ: Were all Tech Spec I Tech Req LCO Entered: / ISFSI CoC I ODCM I Fire Dry-Cask Storage: Protection Req I AMSAC acceptance criteria satisfied? YesD No D N/A D Were all other acceptance Criteria satisfied? Yes D No D N/A D Performed By Print Name Signature Initial Section If all Tech Spec I Tech Req Yes D No D N/A D / ISFSI CoC I ODCM I Fire Protection Req I AMSAC criteria were not satisfied, was an LCO /TR I ODCM I OR action required? (Explain in Remarks) Service Request#: Alert Work Control Reau ired? D

  • PWR only Subseauent Reviews:

Graue: Signature Date Copy of STS sent to Work Control I (next business day) Initials Date Test Coard/Lead Date PERMANENT COMMENTS: Acceptance Criteria Review: SRO Date Time Independent Reviewer Date Time REMARKS: TVA40753 Page 1of4 NPG-SPP-06.9.2-1 [06-14-13]

Browns Ferry Nuclear Plant Unit 3 Surveillance Procedure 3-SR-3.4.9.3&4 Reactor Recirculation Pump Start Limitations Revision 0015 Quality Related Level of Use: Continuous Use Effective Date: 08-03-2012 Responsible Organization: PGM, Engineering Program Group Prepared By: Victor D. Schiavone Approved By: John E. Colvin

I ilEI Job Performance Measure (JPM) SITE: BFN JPM TITLE: 1-Sl-4.7.A.2.A Primary Containment Nitrogen Consumption and Leakage JPM NUMBER: 638 REVISION: I 0 TASK

  • SRO D STA
  • uo D NAUO APPLICABILITY:

TASK NUMBER I TASK TITLE(S):j U~064-SU-05 / Perf?rm Primary Containment Nitrogen Consumption and Leakage SI KIA RATINGS: I R03.7 SRO 4.1 KIA STATEMENT: I 2.2.12 I Knowledge of surveillance procedures RELATED PRA INFORMATION:! N/A SAFETY FUNCTION: I Admin - Equipment Control EVALUATION LOCATION: D In-Plant D Simulator ID Control Room I D Lab

  • Other - List Classroom APPLICABLE METHOD OF TESTING: D Discussion D Simulate/Walkthrough
  • Perform TIME FOR COMPLETION: NA TIME CRITICAL (Y/N)N ALTERNATE PATH (Y/N) N Developed by:

Developer Date (Ensure validator is briefed on exam security per NPG-SPP-17.8.1) (See JPM Validation Checklist in NPG-SPP-17.8.2) Validated by: Validator Date Approved by: Site Training Management Date Approved by: Site Training Program Owner Date 1

I il!D I Job Performance Measure (JPM) OPERATOR: JPM Number 638 RO SRO DATE: --- TASK STANDARD: Perform sections 7.3 through 7.8of1-Sl-4.7.A.2.A and determines Average Leakage meets the Acceptance Criteria PRA: NA REFERENCES/PROCEDURES NEEDED: Procedure 1-Sl-4.7.A.2.A VERIFICATION TIME: 20 Min PERFORMANCE TIME: COMMENTS: Additional comment sheets attached? YES NO RESULTS: SATISFACTORY UNSATISFACTORY SIGNATURE: __________ DATE: ___ EXAMINER 2 (Retain entire JPM for records)

I ll!D I Job Performance Measure (JPM) CLASSROOM: INITIAL CONDITIONS: You are an Operator. The Unit is at 100% power. The time is 2400 hours on 10/2/2014. 1-Sl-4.7.A.2.A, Primary Containment Nitrogen Consumption and Leakage, is in progress. INITIATING CUE: The Unit Supervisor (US) directs you to complete 1-SR-4.7.A.2.A, Primary Containment Nitrogen Consumption and Leakage (provided), by incorporating the 10/02/2014, Midnight 24:00 readings (attached) into the appropriate attachments, and determine whether the acceptance criteria is met. 3

I II!fil I BFN Unit 1 Job Performance Measure (JPM) Primary Containment Nitrogen Consumption and Leakage (Page 1of1) 1 *Sl-4.7.A.2.A Rev.0012 , Page 30 of 43 Suppression Chamber Level Correction KEY Date 1.0 SUPPRESSION CHAMBER LEVEL CORRECTION DATA NOTES

1)

If both Instruments are Operable, then calculate the average of BOTH Operable Instruments by Dividing the sum of their SUPPRESSION CHAMBER LEVEL CORRECTION (column 5) by 2 (two) and record as the TOTAL SUPPRESSION CHAMBER LEVEL CORRECTION.

2)

If one of the instruments is INOP, then use only the Operable Instrumentation Correction Factor for the TOTAL SUPPRESSION CHAMBER LEVEL CORRECTION. A. Suppression Chamber Level Correction Data (Section 7.3.1) ( 1) (2) (3} (4) (5) Initial Ending SupprChbr ' Surpr Chhr SupprChbr Change in Conversion Level Level (IN.) LEVEL (IN.) Suppr Chbr Factor Correction Instrument (0000 Hours} (2400 Hours) Level (IN.) 909.8 FT3/IN. (FT3) 1-Ll-64-54A -s?3 -so= -o,3 x 909.8 = -272. 94 1-Ll-64-66 I - *-1, o 3,7 -0.3 x 909.8 = - 222.91--

8.

Total Suppression Chamber Level Correction Calculation (Section 7.3.2) Column 5(ft3 ) Column 5(ft3) + for 1-Ll-64-54A for 1-Ll-64-66 2-------- =Average Suppression Chamber Level 272. q4 (ft 3 ) +- 272.14(ft 3 ) 1-LI-54-54.A. l-Ll-64-66 =- 272.'J4(ft 3 ) 2 KEY 4 uo !NIT 1//). /("} ti uo

I ll!l I BFN Unit 1 Job Performance Measure (JPM) Primary Containment Nitrogen Consumption and Leakage (Page 1of1) Drywell Control Air Leakage 1-S 1-4. 7.A.2.A Rev.0012 Pa~e 31 of43 A.

Jrywell Control Air Leakage {Section 7.4)

Drywell Control Air Line A. FLOW UW CONT AIRTO X-50, 1-flQ-032-0092 f 1) (2) (3) ENDING (2400 hours) 1252'103 INITIAL (0000 houra) I") 1.,-, 11 -{ )~ _,J I A I Drywell control Air Line B Flow OW CONT AIR TO X-22, 1-FIQ-032-0075 {1) EN[')ING (2400 !mun;) (2) INITIAi (*)000 huu11S) Drywell Control Air Leakage 1-FI0-032-0092 1-FI0-032-0075 Difference (Column 3) + Difference (Column 3) 413 5 = Direrence (3) nitten=mr:P. Total uo

0\\ [ BFN Primary Contai11ment Nitrogen 1~Sl-4.7.A.2.A Unit 1 Consumption and Leakage Rev. 0012 Pa e 33of43 A. Drywell and Suppression Chamber Data (Page 2 of 4} Containment Air Temperature Correction ( ;., t;'y Date t 1 A/ DRYWELL i Differential Suppression Chaml::e* 0000 hours 2400 hours Pressure Temp ("F~ (1) (2} (3l 1-Tl-64-52.AB 1-Pl-64-135 1-Pl-64-136 or ~* (psig) {psig) Po, /. L/ (! P1<1

', 3£1 PA, t44 p{\\l (B)

DRYlflfELL VENTING CORRECTIOl'J /.40 1-XR-64-50 T,., /'j( T., I (9) SUPRESSION CHMBR VENTING CORRE Clim~ I Pressure i I (4) (5) 1-PDl*64*13t 1*PDl*64*138 {psid) (paid) IP... 1,17 P ** /, :2,. 'j l pA, r.2g P,.. I. (10) Total VENTING CORRECTION __ =:_ __ FT3 + --F=--- FT 3 = _ __.:.;. __ FT'.l Air Temp Level -- (S) (7) '-XR-64-52 Point WF) or 1*1R-64-161 1 *Ll-64-54A (Point 10) or 66 '/'i ) Tei NIA T.02 .2 LA - 5, 0 uo ~ c... 0 C" "tJ CD ~ ... 3 m

,:::, n CD 3:

CD m c Cll - c... "tJ 3: -

I U!l I Job Performance Measure (JPM) BFN Unit 1 Primary Containment Nitrogen Consumption and Leakage {Page 1 of2} 1-81-4.7.A.2.A Rev.0012 Paae 42 of 43 Average Nitrogen Consumption and Leakage Date A. Net Nitrogen Leakage (Section 7.8}

1.

SUM all Gas additions to obtain the Total Addition: Gas Addnion to the Drywell Total Drywell Control Air Leakage 21 &,~ ft~ Attachment 2, Section A Cumulative Nitrogen Makeup + 0 ft3-Attachment 4, Section A Total Gas Addition = 2Lb. CJ ft3

2.

Air Temperature Correction Air Temperature Total DW and SC Temperature Correction I of ft3 Attachment 3, Section A

3.

SUM all the Correction Factors to obtain a Total Correction Factor: Correction Factor Total Supp Chamber Level Correction 272. ~ 4fl3 Attachment 1, Section B Total Venting Correction using 1-FIC 84-20 l(..,0() ft3 Attachment 5, Section A Total Alternate Venting Correction + 0 ft3 Attachment 6, Section B Total Correction Factor - 23 2 7.0'7 ft3

4.

CALCULATE Net Nitrogen leak.age: Total Gas Addition - Total OW and SC Tempe Correction -Total Correction Factor Nitrogen Leakage Total Gas Addition 2l'21 ft3 (Step 1 above) Total DW and SC Temperature Correction 0 ft3(Slep 2 above) I Total Correction Factor - 232'7.D!oif(Step 3 above) Net Nitrogen leakage = - f5B.Obtt3 7 l

I ll!l I I BFN UnU 1 Job Performance Measure (JPM) Primary Containment Nitrogen Consumption and Leakage (Page 2 of 2) 1-Sl-4. 7.A.2.A Rev.0012 Paae43 of 43 Average Nitrogen Consumption and Leakage Date NOTES

1)

For calculation purposes, a day consist of 24*hours. During the days when the time changes to Daylight Savings Time (DST) 23-hours will be used. When returning to Central Standard Time (CST) 25-hours will ba used.

2)

The average nitrogen leakage (adjusted) must be <542 SCFH (Step 6.0A.1 ). NOTIFY the Unit Supervisor (US) if the nitrogen leakage exceeds 542 SCFH (REFER TO 1-AOl-64-7 and Tech Specs 3.6.1.1). B. Average Nitrogen Leakage (Section 7.8.2) Calculate the Average Nitrogen Leakage N. L k Net nitrogen leakagex 1.136 Avg. 1trogen ea *age=---~--~- Hours during tlte cay ttSS.o{:. ft 3 )x l.136 Avg. Nitrogen Leakage= ( 4 ) Avg. Nitrogen Leakage _2. __ Hours -14B {AC) SCFH EY 8 [&?(AC} .UP o)// IV

I ll!fil I Job Performance Measure (JPM) START TIME ___ STEP/STANDARD SAT/ UNSAT Step 1: 7.8.1 Attachment 7 - Section A - Net Nitrogen Leakage [1] Total Drywell Control Air Leakage, - RECORD the Total Critical Step Drywell Control Air Leakage from Attachment 2 Section A SAT in the Gas Addition to the Drywell table. UN SAT Standard: N/A Refers to Attachment 2 and records 2169 +/- 0 ft3for Total Drywell Control Air Leakage on Attachment 7. Step 2: [2] Cumulative Nitrogen Makeup, - RECORD the total Critical Step cumulative nitrogen makeup from Attachment 4 Section A in the Gas Addition to the Drywell table. SAT Standard: UNSAT Refers to Attachment 4 and records 0+/- 0 ft3 for cumulative N/A nitrogen makeup on attachment 7. Step 3: [3] CALCULATE the Total Gas Addition as follows: ADD all the Gas addition types together from the Gas Critical Step Addition Table an RECORD the sum as the Total Gas SAT Addition in the Gas Addition to the Drywell table. Standard: UNSAT Adds the Total Drywell Control Air Leakage and the Cumulative N/A Nitrogen Makeup and determines the Total Gas Addition is 2169 +/- 0 ft3. 9

I rl!l I Job Performance Measure (JPM) STEP/STANDARD SAT/ UNSAT Step 4: [4] Total Drywell and Suppression Chamber Temperature Critical Step Correction, - RECORD the TOTAL VENTING CORRECTION from Attachment 3, Section A in the SAT Correction Factor table. Standard: UN SAT Refers to Attachment 3 and records 0 +/- 0 ft3 for Total OW and SC NIA Temperature Correction on Attachment 7. Step 5: [5] Total Suppression Chamber Level Correction, - RECORD Critical Step the total Suppression Chamber level correction from, Section A in the Correction Factor table. SAT Standard: UNSAT Refers to Attachment 1 and records -272.94 OR -272.9 ft3 for NIA Total Suppression Chamber Level Correction on Attachment 7. Step 6: [6] Total Venting Correction using 1-FIC 84-20, - RECORD Critical Step the total Drywell Venting Correction from Attachment 5, Section A in the Correction Factor table SAT Standard: UN SAT Refers to Attachment 5 and records 2600 +/- 0 ft3 for Total Venting NIA Correction. 10

liml Job Performance Measure (JPM) STEP/STANDARD SAT I UNSAT Step 7: [8] CALCULATE the Total Correction Factor as follows ADD all the Correction Factor Types together from the Critical Step Correction Factor Table and RECORD the sum as the Total Correction Factor in the Correction Factor table. SAT Standard: UNSAT Adds the Total Suppression Chamber Level Correction, the Total N/A Venting Correction, and the Total Alternate Venting Correction together and determines the Total Correction Factor is 2327.06 OR 2327.1 ft3. Step 8: [9] CALCULATE the Net Nitrogen Leakage as follows Total Gas Addition for the Net Nitrogen Leakage and Critical Step SUBTRACT the Air Temperature calculation and SAT SUBTRACT the Total Correction Factor. Standard: UNSAT Subtracts the Total DW and SC Temperature Correction and the N/A Total Correction Factor from the Total Gas Addition and determines the Net Nitrogen Leakage is -158.06 OR -158.1 ft3. 11

liml Job Performance Measure (JPM) STEP I STANDARD Step 9: NOTE Leakage rates, for comparison purposes, should always be converted to standard flow rate conditions (flow at 70°F, one standard atmosphere). Since nitrogen gas is supplied by evaporating liquid nitrogen and heating it to approximately 70°F then reducing the pressure to 2.0 psig the conversion is:

14. 7psia + 2.0psig X 460°R + 70° = 1.136 14.7psi 460°R + 70°F Where: 14. 7 psia = 1 standard atmosphere 2.0 psig = nitrogen supply pressure 460°R = Fahrenheit to Rankine conversion factor 70°F = degrees Fahrenheit of nitrogen, actual and standard For calculation purposes, a day consists of 24-hours. During the days when the time changes to Daylight Savings Time (DST) 23-hours will be used. When returning to Central Standard Time (CST) 25-hours will be used. To average the net nitrogen usage (in ft3) for a day, a 24 hour period is normally used and the results are expressed in standard cubic feet per hour. The net nitrogen leakage is multiplied by a conversion factor 1.136, then divided by the number of hours in the day. The result gives the average nitrogen leakage in standard cubic feet per hour for that day. When Daylight Savings Time and Central Standard Time changes take place, the appropriate number of hours will be used instead of 24 (hours).

[1] MULTIPLY the net nitrogen leakage from Attachment 6, Section A, (Nitrogen Leakage table) by (1.136/Hours during the day). [2] RECORD the result on the Average Nitrogen Leakage line. Standard: Multiplies Net Nitrogen Leakage of -158.06 OR -158.1ft3 by 1.136 and divides by 24 hours to determine an Average Nitrogen Leakage of -7.48 OR -7.5 SCFH. Determines that the Average Nitrogen Leakage is less than 542 SCFH (AC) and initials for the Acceptance Criteria. 12 SAT/ UN SAT Critical Step _SAT _UNSAT _N/A

IUEI Job Performance Measure (JPM) STEP/STANDARD SAT/ UNSAT Step 19: Critical Step The applicant determines and indicates whether the surveillance SAT acceptance criterion is met or not. Standard: UNSAT The applicant indicates the surveillance acceptance criterion is N/A met. CUE: ANOTHEROPERATOR WILL COt<fTINUE FROM HERE STOP TIME --- END OF TASK 13

I nE I Job Performance Measure (JPM) Provide to Applicant INITIAL CONDITIONS: You are an Operator. The Unit is at 100% power. The time is 2400 hours on 10/2/2014. 1-Sl-4.7.A.2.A, Primary Containment Nitrogen Consumption and Leakage, is in progress. INITIATING CUE: The Unit Supervisor (US) directs you to complete 1-SR-4.7.A.2.A, Primary Containment Nitrogen Consumption and Leakage, by incorporating the 10/02/2014, Midnight 24:00 readings (attached) into the appropriate attachments, and determine whether the acceptance criteria is met. 14

I rmll Job Performance Measure (JPM) Provide to Applicant Data recorded at 2400 on 10/02/2014 To be used to complete 1-Sl-4.7.A.2.A Primary Containment Nitrogen Consumption and Leakage Suppression Chamber Level 1-Ll-64-159A 14.8 Ft 1-Ll-64-54A (-) 5.0 inches 1-IL-64-66 (-) 3.7 inches Drywall Control Air Line Flow 1-FIQ-032-0092 1252903 Ft3 1-FIQ-032-0075 347673 Ft3 Drywell Pressure 1-P 1-64-135 1.44 psig 1-Pl-64-136 1.40 psig 1-Pl-64-678 0 psig Drywell Temperature 1-XR-64-50 133°F 1-Tl-64-52AB 141°F Drywell-Suppression Chamber Differential Pressure 1-PDl-64-137 1.28 psid 1-PDl-64-138 1.25 psid Suppression Chamber Air Temperature 1-TR-64-161 Point 10 90.8°F 1-XR-64-52 Point 1 94.2°F Containment venting data was recorded in Attachment 5 when venting was completed. 15

Surveillance Task Sheet (STS) I Work Order#: 115277270 I PM#: P1402 Procedure: 1-Sl-4.7.A 2.A Page __l_ of __ nue: 1*Sl-4.7.A 2.A* PRIMARY CONTAINMENT NITROGEN CONSUMPTION & LEAKAGE /0A ~{_ 1°/L i J<f. Data Sheets Attached: !};r: Authorization to Begin: SRO Date & Time Port Grp: OPS Unit: 1 Loop/Div: /NA Test Reason: Periodic /D /1_ /_/1_ 0000 Due Date: 1010V14 Start Date & Time Completion Date & Time Frequency: 1 DAYS Tech Spec: Y ASME XI: Applicable Modes: Pert Modes: Clearance Required: N EQ: LCO Entered: N Dry-Cask Storage: N Was this a complete or partial performance? (Explain "Partial" in Remarks below) Complete [ l P;irt\\;11 Performed By: Print Name Signature Initial Section Were all Tech Spec I Tech Req 1 ISFSI CoC I ODCM I ),,hn J.:e .~v~ 30 0 p<; Fire Protection Req I AMSAC* acceptance criteria satisfied? Yes [ J No ( J NIA [) Were all other acceptance criteria satisifed? Yes [ l No (I NIA [ l If all Toch Spoc I Tech Req I ISFSI CoC I ODCM I Fire Protection Req I AMSAc* criteria were not satisfied. was an LCO I TR t OOCM r OR action roquired? (Explain in Remarks) Yes ( J No (I N/A [ l Service Request#: Alert Work Control Requlrad? [I "PWR only. Subsequent Reviews: Group Signature Date Copy of STS sent to Work Control (next business day) I OF Initials Date NSS!': Test Coord/Lead Dato Acceptance Criteria Review: SRO Date & Time Permanent Comments: Remarks: SHALL BE PERFORMED EACH DAY 'M-ilLE THE REACTOR IS IN THE RUN MODE (MODE 1) AND PRIMARY CONTAINMENT IS Independent Reviewer Date & Time INERTED.

  • B!lWi!C~:i; I llllll lllll lllll lllll lllll lllll lllll lllll lllll llll llll TVA RESTRICTED INFORMATION

Browns Ferry Nuclear Plant Unit 1 Surveillance Instruction 1-51-4. 7.A.2.A Primary Containment Nitrogen Consumption and Leakage Revision 0012 Quality Related Level of Use: Continuous Use Level of Use or Other Information: Key Number P1402 Effective Date: 11-24-2014 Responsible Organization: OPS, Operations Prepared By: David Threadgill Approved By: Walter R. Miller

BFN Primary Containment Nitrogen 1-Sl-4. 7.A.2.A Unit 1 Consumption and Leakage Rev.0012 PaQe 2of43 Current Revision Description Type of Change: Enhancement Tracking Number: 013 PC Rs: None Documentation: None In Step 7.8.2[1], corrected Attachment reference. Changed Attachment 6 to Attachment 7 This change is a Minor/Editorial change as defined in NPG-SPP 01.2 (Administration of Site Technical Procedures) and NPG-SPP 03.14 Section 3.2.11 (Licensing Compliance review) Section 3.2.1 and does not require a 10 CFR 50.59 evaluation or a Licensing Compliance Review.

BFN Primary Containment Nitrogen 1-Sl-4. 7.A.2.A Unit 1 Consumption and Leakage Rev.0012 Page 3of43 Table of Contents

1.0 INTRODUCTION

.......................................................................................................... 5 1.1 Purpose........................................................................................................................ 5 1.2 Scope............................................................................................................................ 5 1.3 Frequency..................................................................................................................... 5

2.0 REFERENCES

............................................................................................................. 6 2.1 Technical Specifications............................................................................................... 6 2.2 Technical Requirements Manual - TRM........................................................................ 6 2.3 Final Safety Analysis Report......................................................................................... 6 2.4 Plant Instructions.......................................................................................................... 6 2.5 Plant Drawings.............................................................................................................. 7 2.6 Plant Generated Calculations....................................................................................... 7

2. 7 Miscellaneous............................................................................................................... 7 3.0 PRECAUTIONS AND LIMITATIONS........................................................................... 8 3.1 General Precautions..................................................................................................... 8 3.2 Operability and LCO's................................................................................................... 8 3.3 Equipment..................................................................................................................... 8 3.4 Initiation/Isolation/Trips................................................................................................. 8 3.5 Interlocks...................................................................................................................... 8 3.6 Performance Testing.................................................................................................... 9 4.0 PREREQUISITES....................................................................................................... 12 5.0 SPECIAL TOOLS AND EQUIPMENT RECOMMENDED.......................................... 12 6.0 ACCEPTANCE CRITERIA......................................................................................... 12 7.0 PROCEDURE STEPS................................................................................................ 13 7.1 Initial Requirements and Notifications......................................................................... 13 7.2 Data Collection As Close to Midnight (0000 Hour) As Possible.................................. 14 7.3 Suppression Chamber Level....................................................................................... 16 7.3.1 - Section A - Suppression Chamber Level Corrections Data........................................................................................... 16 7.3.2 - Section B - Total Suppression Chamber Level Correction..................................................................................................... 16 7.4 Calculating the Drywell Control Air Leakage............................................................... 17

BFN Primary Containment Nitrogen 1-Sl-4. 7.A.2.A Unit 1 Consumption and Leakage Rev.0012 Page 4of43 Table of Contents (continued) 7.4.1 - Calculate the Drywell Control Air Line A Leakage........................................................................................................ 17 7.4.2 - Calculate the Drywell Control Air Line B Leakage........................................................................................................ 17 7.4.3 Calculate The Total Drywell Control Air Leakage.......................................... 17 7.5 Air Temperature Correction........................................................................................ 18 7.5.1 - Section A - Drywell and Suppression Chamber Data.............................................................................................................. 18 7.6 Nitrogen Makeup........................................................................................................ 20 7.6.1 - Section A - Nitrogen Makeup Data....................................... 20 7.7 Containment Venting.................................................................................................. 23 7.7.1 - Section A - Containment Venting Data using 1-FIC-84-20.................................................................................................. 23

7. 7.2 - Section A - Alternate Containment Venting Data................................................................................................. 24 7.7.3 Section B Alternate Containment Venting Correction..................................................................................................... 26 7.8 Average Nitrogen Consumption and Leakage............................................................ 27 7.8.1 - Section A - Net Nitrogen Leakage........................................ 27 7.8.2 - Section B - Average Nitrogen Leakage................................. 28
7. 9 Completion and Notifications...................................................................................... 29 8.0 ILLUSTRATIONS/ATTACHMENTS........................................................................... 29 : Suppression Chamber Level Correction................................................ 30 : Drywell Control Air Leakage.................................................................... 31 : Containment Air Temperature Correction.............................................. 32 : Nitrogen Makeup/Suppression Chamber Level..................................... 36 : Containment Venting Correction............................................................. 37 : Alternate Venting Correction................................................................... 38 : Average Nitrogen Consumption and Leakage....................................... 42

BFN Primary Containment Nitrogen 1-51-4. 7.A.2.A Unit 1 Consumption and Leakage Rev.0012 Paqe 5of43

1.0 INTRODUCTION

1.1 Purpose This Surveillance Instruction provides the necessary steps to monitor the primary containment nitrogen consumption rate (i.e.. primary containment system leakage) in compliance with the requirements in Technical Specification 3.6.1.1 and TRM 3.6.2, and 3.6.5. 1.2 Scope Primary containment nitrogen consumption is monitored to determine the average daily nitrogen consumption. Corrections are made for Suppression Chamber level changes and Drywell/Suppression Chamber venting that may occur. The average nitrogen leakage is calculated using data gathered during the day of this test. For calculation purposes, a day consists of 24-hours. During the days when the time changes to Daylight Savings Time (DST) 23-hours will be used. When returning to Central Standard Time (CST) 25-hours will be used. 1.3 Frequency This Surveillance Instruction shall be performed each day (24-hour duration except the days converting to Daylight Saving Time and returning to Central Standard Time) and reviewed each shift while the reactor is in the RUN mode (Mode 1) and primary containment is inerted. This procedure is initially started when the conditions are met during Reactor Startup and remains in process until the following Midnight (2400 Hours). This procedure should be initiated at Midnight (0000 Hours) and remain in process for a 24 Hour period (until the following Midnight (2400 Hours)) or when conditions are no longer met during Reactor Shutdown per Tech Specs.

BFN Primary Containment Nitrogen 1-Sl-4. 7.A.2.A Unit 1 Consumption and Leakage Rev.0012 Paqe 6 of 43

2.0 REFERENCES

2.1 Technical Specifications Section 3.6.1.1, Primary Containment 2.2 Technical Requirements Manual - TRM Section 3.6.2, Oxygen Concentration Monitors Section 3.6.5, Nitrogen Makeup to Containment 2.3 Final Safety Analysis Report Section 5.2.2.8, Primary Containment-Safety Design Basis Section 5.2.3.8, Containment lnerting System Section 5.2.4.5, Primary Containment Leakage Analysis Section 5.2.5.1, Primary Containment Integrity and Leak-Tightness Table 5.2-1, Principal Design Parameters and Characteristics of Primary Containment 2.4 Plant Instructions 1-AOl-64-7, Primary Containment N2 Usage High Abnormal Operating Instructions O-Ol-57C, 208/120V AC Electrical System Operating Instructions 1-01-64, Primary Containment System Operating Instructions 1-01-84, Containment Atmosphere Dilution System Operating Instructions NPG-SPP-06.9.1, Conduct of Testing NPG-SPP-06.9.2, Surveillance Test Program

BFN Primary Containment Nitrogen 1-Sl-4. 7.A.2.A Unit 1 Consumption and Leakage Rev.0012 Page 7of43 2.5 Plant Drawings 0-47E610-76-1, Mechanical Control Diagram Containment lnerting System 1-47E610-76-1, Mechanical Control Diagram Containment lnerting System 1-4 7E610-64-1, 2, and 3, Mechanical Control Diagram Primary Containment System 1-47E610-84-1, Mechanical Control Diagram Containment Atmosphere Dilution System 1-4 7E860-1, Flow Diagram Containment lnerting System 1-4 7E862-1, Flow Diagram Containment Atmosphere Dilution System 1-4 7E865-1, Flow Diagram Heating and Ventilating Air Flow 2.6 Plant Generated Calculations PGC-001-064-0, Change in Torus Free Volume per 1" of Water Level 2.7 Miscellaneous BFPER970886, Calculating Leakage when CAD is cross-tied to Drywell Control Air

BFN Primary Containm~nt Nitrogen 1-Sl-4. 7.A.2.A Unit 1 Consumption and Leakage Rev.0012 Page 8 of 43 3.0 PRECAUTIONS AND LIMITATIONS 3.1 General Precautions A. This procedure should be initiated at Midnight (0000 Hours) and remain in process for a 24 Hour period (until the following Midnight (2400 Hours)). B. If it is necessary to begin a new revision of the procedure before the time period is completed, then the appropriate data must be transferred to the new document and the two procedures maintained together. C. For an INDEPENDENT REVIEWER signature, the STA or SRO cannot perform any actions or signoffs in the body of the procedure. This will ensure an adequate review of the procedure. 3.2 Operability and LCO's A. If Nitrogen leakage exceeds 542 SCFH, 1-AOl-64-7, and TECH SPECS must be referred to for further action.

1.

If 24-Hour average Nz makeup to the primary containment is > 542 SCFH then Primary Containment must be declared INOP immediately. (Refer to LCO 3.6.1.1.) B. If the nitrogen consumption demonstrates a trend that will be greater than 542 SCFH for the 24-hour period, notify the Unit Supervisor (US) immediately. 3.3 Equipment A. When a Drywell Control Air Totalizer is INOP, the OWCA System Engineer will use the AUO rounds to determine the average flow to be used for N2 Drywell Control Air Flow. B. When a Drywell Control Air Totalizer is INOP and a break or a leak occurs in the drywell from an air line, the number of times the drywell is vented will rise based on the severity of the leak or break. System Engineering should monitor and address any rise in Venting Requirements to determine if it is caused by a Drywall Control Air Line leak or due to atmospheric conditions. 3.4 Initiation/Isolation/Trips None 3.5 Interlocks None

BFN Primary Containment Nitrogen 1-Sl-4. 7.A.2.A Unit 1 Consumption and Leakage Rev.0012 Page 9of43 3.6 Performance Testing A. Since changes in Suppression Chamber level change the Suppression Chamber free volume, the Torus atmospheric pressure will change, although nitrogen may not have been lost or added.

1.

The Suppression Chamber level may change for any number or events such as venting the Orywell/Suppression Chamber, pumping down the Suppression Chamber, MRSVs Leakage or testing Core Spray, RHR, HPCI, or RCIC Systems.

2.

The correction for level changes is based on the assumption that the Suppression Chamber level change is relatively small {-1" to -7.25" indicated level) allowing the effect of Suppression Chamber curvature to be neglected. Therefore, the 909.8 cubic feet change in volume per one inch change in Suppression Chamber level is assumed constant. B. Changes in either the Orywell or Suppression Chamber Air Temperature would cause a change in Containment Pressure under ideal conditions. Due to the continuous Drywell Control Air addition and possible venting during the 24 hour period the changes in containment pressures may not be as expected. Therefore when a change of more than 2 °F in either area occurs a Temperature Correction will be performed for that area's Air Temperature, otherwise zero "O" will be used for the correction factor. C. For Sections 7.5 and 7. 7.1 if one pressure indicator and/or differential indicator is inoperable, then the appropriate column on the Attachment is to be marked NIA, the INOP indicator noted on Attachment 1, and dividing by 2 is to be omitted for that particular term in the equation. D., Section B should be used to calculate the venting correction factor when any of the following instrumentation is unavailable.

1.

Both DRYWELL PRESSURE, 1-Pl-64-135 and 1-Pl-64-136

2.

DRYWELL TEMPERATURE, 1-Tl-64-52AB E., Section B should be used to calculate the venting correction factor when any of the following instrumentation is unavailable.

1.

Both DRYWELL PRESSURE, 1-Pl-64-135 and 1-Pl-64-136

2.

Both OW/SUPPR CHBR DIFF PRESS, 1-PDl-64-137 and 1-PDl-64-138

3.

DRYWELL TEMPERATURE, 1-XR-64-52

4.

SU PPR POOL WATER LEVEL, 1-Ll-64-54A and 1-Ll-64-66.

BFN Primary Containment Nitrogen 1-Sl-4. 7.A.2.A Unit 1 Consumption and Leakage Rev.0012 PaQe 10 of 43 3.6 Performance Testing (continued) F. Drywell/Suppression Chamber venting may be required to maintain Drywell pressure within limits during changes in barometric pressure, maintenance on Drywell Delta P Air Compressor, or other similar events. When using the Alternate Venting Correction equation in Attachment 6, the following assumptions are used.

1.

The Drywell free volume is 159,000 cubic feet.

2.

The Suppression Chamber free volume is 126,200 cubic feet at -1 inches (SUPPR POOL WATER LEVEL, 1-Ll-64-54A, or SUPPR POOL WATER LEVEL, 1-Ll-64-66), and an additional 909.8 cubic feet of free volume for each inch that water level is lowered.

3.

The actual venting process is a rapid event so barometric pressure changes can be neglected.

4.

The average Drywell temperature change is represented by DRYWELL TEMPERATURE, 1-Tl-64-52AB, and DRYWELL TEMPERATURE/PRESSURE 1-XR-64-50.

5.

Orywell and Suppression Chamber nitrogen pressures are low enough to use the ideal gas law as a model, i.e. v = 1 -[ PB TA ] x v c p T t A B Where: Ve= Venting Correction P6= Drywall or Suppression Chamber pressure before venting PA= Drywell or Suppression Chamber pressure after venting T 6= Drywell or Suppression Chamber temperature before venting TA= Drywell or Suppression Chamber temperature after venting V1= Total free volume of Drywall or Suppression Chamber

6.

The Suppression Chamber water and atmospheric temperatures are in equilibrium.

BFN Primary Containment Nitrogen 1-Sl-4. 7.A.2.A Unit 1 Consumption and Leakage Rev.0012 Page 11 of 43 3.6 Performance Testing (continued) G. Drywell/Suppression Chamber Venting Correction Factor are absolute values. (No Negative totals) H. TSB 3.3.3.1 (PAM instrumentation) states that for OW temperature that two wide range drywell atmosphere temperature signals are transmitted from separate temperature sensors and are continuously recorded and displayed on one CR recorder (XR-64-50) and one control room indicator (Tl-64-52AB). Therefore, it's reasonable that either indicator should be adequate for use in the calculation of N2 consumption.

BFN Primary Containment Nitrogen 1-Sl-4. 7.A.2.A Unit 1 Consumption and Leakage Rev.0012 Page 12 of 43 Date I 0 / 2. /; 'l 4.0 PREREQUISITES VERIFY this copy of 1-Sl-4. 7.A.2.A is the most current revision. OBTAIN a Surveillance Task Sheet {STS) for this procedure and Work Activity. (Key Number P1402) VERIFY that Cabinet 2, Panel 9-9 is energized in accordance with 0-01-57C, 208/120V AC Electrical System Operating Instruction. 5.0 SPECIAL TOOLS AND EQUIPMENT RECOMMENDED A. Calculator 6.0 ACCEPTANCE CRITERIA JJ) 5D A. Responses which fail to meet the following acceptance criteria constitute unsatisfactory surveillance instruction results and require the immediate notification of the Unit Super\\tisor at the time of failure:

1.

Nitrogen makeup to the primary containment, averaged over 24 hours (corrected for Suppression Chamber level changes and Drywall/Suppression Chamber venting) is less than 542 standard cubic feet per hour (SCFH). B. Steps which determine the above criteria are designated by (AC) next to the initials blank.

BFN Primary Containment Nitrogen 1-Sl-4.7.A.2.A Unit 1 Consumption and Leakage Rev.0012 Paqe 13of43 Date /0,/2/;y NOTES

1)

This procedure is required to be initiated at Midnight which is represented as (0000 Hours) and remain in process for a 24 Hour period (until the following Midnight which is represented as (2400 Hours)). These times are used to represent the difference from the start and the completion of this SR and may not match the proper military time that is used by the electronic narrative logs.

2)

If it is necessary to begin a new revision to the procedure before the time period is completed, the appropriate data must be transferred to the new document and the two procedures maintained together. 7.0 PROCEDURE STEPS 7.1 Initial Requirements and Notifications (~ (~ i ($> VERIFY the Precautions and Limitations in Section 3.0 have been reviewed. VERIFY the Prerequisites in Section 4.0 are satisfied. On the Surveillance Task Sheet (STS) OBTAIN Authorization Signature and Date/Time from the Unit Supervisor to perform this surveillance. On the Surveillance Task Sheet (STS) RECORD the Start Date & Time. RECORD the date on each data sheet, Attachments 1 through 7. -so .JD

1)
2) 7.2 BFN Primary Containment Nitrogen 1-Sl-4. 7.A.2.A Unit 1 Consumption and Leakage Rev.0012 Page 14 of 43 Date

/0 lz ); 7 NOTES This procedure should be initiated by the midnight shift Unit Supervisor or by the Unit Supervisor of any shift meeting the requirements in Section 1.3. For the first run of the 24-hour period, the previous cumulative total is zero since totals are not carried over from the previous 24-hour test. Data Collection As Close to Midnight (0000 Hour) As Possible ~ ~ RECORD on Attachment 1 Part A, the initial Suppression Pool Level (0000 Hour), in column (1) for each of the following instruments (if available) on Panel 1-9-3. rp SUPPR POOL WATER LEVEL, 1-Ll-64-54A rj) SUPPR POOL WATER LEVEL, 1-Ll-64-66 RECORD on Attachment 2 in the "INITIAL" column, the Orywell Control Air Loop A flow from the N2 Containment lnerting System, from one of the following: (:/J OW CONT AIR TO X-50, 1-FIQ-032-0092 OR Average flow as determined by the OWCA System Engineer if OW CONT AIR TO X-50, 1-FIQ-032-0092, is INOP. (REFERENCE Step 3.3A) .:5[) RECORD on Attachment 2 in the "INITIAL" column, the Orywell Control Air Loop B flow from the N2 Containment lnerting System, from one of the following: r:t OW CONT AIR TO X-22, 1-FIQ-032-0075 OR Average flow as determined by the OWCA System Engineer if OW CONT AIR TO X-22, 1-FIQ-032-0075, is INOP. (Reference Step 3.3A) 5!)

BFN Primary Containment Nitrogen 1-51-4.7.A.2.A Unit 1 Consumption and Leakage Rev.0012 Paqe 15 of 43 Date lo/z/;y 7.2 Data Collection As Close to Midnight (0000 Hour) As Possible (continued) NOTE It is assumed in 3.6F.6 that the suppression chamber water and atmospheric temperatures are in equilibrium, therefore the use of the average suppression pool water temperature is an acceptable substitute in place of the suppression chamber air temperature. IF SUPP CHBR TEMP,1-TE-64-52B on SUPPRESSION CHAMBER TEMPERATURE/PRESSURE, 1-XR-64-52 (point 1), is unavailable, THEN Suppression Pool Water Temperature, 1-TR-64-161 (Point 10) can be substituted. [BFNPER 607653-002] RECORD on Attachment 3 in the 0000 Hours column the following data. 0 At the beginning of the surveillance (0000 hours), RECORD the OW CONT AIR TO X-22, 1-FIQ-032-0075, (Orywell Control Air Loop B) in the column (2) "INITIAL" (0000 hours). [2] At the end of the surveillance (2400 hours), RECORD the OW CONT AIR TO X-22, 1-FIQ-032-0075, (Orywell Control Air Loop B) in the column (1) "ENDING" (2400 hours). [3] CALCULATE the daily difference for OW CONT AIR TO X-22, 1-FIQ-032-0075, (Orywell Control Air Loop B) Column (1) - Column (2) =Difference (Column 3). 7.4.3 Calculate The Total Drywall Control Air Leakage SUM the OW CONT AIR TO X-50, 1-FIQ-032-0092, (Drywell Control Air Loop A) Difference and OW CONT AIR TO X-22, 1-FIQ-032-0075, (Orywell Control Air Loop B) Difference. 1-FIQ-032-0092 (Difference)+ 1-FIQ-032-0075 (Difference)= Total.

BFN Primary Containment Nitrogen 1-Sl-4. 7.A.2.A Unit 1 Consumption and Leakage Rev.0012 Paae 18 of 43 Date 1°/z/;y 7.5 Air Temperature Correction NOTES

1)

Drywell/Suppression Chamber Venting Correction Factor are absolute values. (No Negative totals)

2)

TSB 3.3.3.1 (PAM instrumentation) states that for OW temperature that two wide range drywell atmosphere temperature signals are transmitted from separate temperature sensors and are continuously recorded and displayed on one CR recorder (XR-64-50) and one control room indicator (Tl-64-52A8). Therefore, it's reasonable that either indicator should be adequate for use in the calculation of N2 consumption.

3)

It is assumed in 3.6F.6 that the suppression chamber water and atmospheric temperatures are in equilibrium, therefore the use of the average suppression pool water temperature is an acceptable substitute in place of the suppression chamber air temperature. IF SUPP CHBR TEMP,1-TE-64-528 on SUPPRESSION CHAMBER TEMPERATURE/PRESSURE, 1-XR-64-52 (point 1 ), is unavailable, THEN Suppression Pool Water Temperature, 1-TR-64-161 (Point 10) can be substituted. [BFNPER 607653-002) ~:£~j_> Attachment 3 - Section A - Drywell and Suppression Chamber Data At the beginning of the surveillance (0000 hours), RECORD on in the 0000 Hours column the following data. DRYWELL PRESSURE 1-Pl-64-135 DRYWELL PRESSURE 1-Pl-64-136 DRYWELL TEMPERATURE 1-Tl-64-52A8 or 1-XR-64-50 DW/SUPPR CHBR DIFF PRESS 1-DPl-64-137 DW/SUPPR CHBR DIFF PRESS 1-DPl-64-138 SUPP CHBR TEMP,1-TE-64-528 on SUPPRESSION CHAMBER TEMPERATURE/PRESSURE, 1-XR-64-52 (point 1) OR IF SUPP CHBR TEMP, 1-TE-64-528 on SUPPRESSION CHAMBER TEMPERATURE/PRESSURE, 1-XR-64-52 (point 1), is unavailable, THEN Suppression Pool Water Temperature, 1-TR-64-161(Point10) can be substituted. [BFNPER 607653-002]

BFN Primary Containment Nitrogen 1-Sl-4.7.A.2.A Unit 1 Consumption and leakage Rev.0012 Page 19 of 43 Date / o /z,J1y 7.5.1 - Section A - Drywell and Suppression Chamber Data (continued) [2] At the end of the surveillance (2400 hours), RECORD on in the 2400 Hours column the following data. DRYWELL PRESSURE 1-Pl-64-135 DRYWELL PRESSURE 1-Pl-64-136 DRYWELL TEMPERATURE 1-Tl-64-52AB or 1-XR-64-50 DW/SUPPR CHBR DIFF PRESS 1-DPl-64-137 DW/SUPPR CHBR DIFF PRESS 1-DPl-64-138 SUPP CHBR TEMP, 1-TE-64-528 on SUPPRESSION CHAMBER TEMPERATURE/PRESSURE, 1-XR-64-52 {point 1) OR IF SUPP CHBR TEMP, 1-TE-64-528 on SUPPRESSION CHAMBER TEMPERATURE/PRESSURE, 1-XR-64-52 (point 1), is unavailable, THEN Suppression Pool Water Temperature, 1-TR-64-161 (Point 10) can be substituted. [BFNPER 607653-002) Suppression Pool Level 1-Ll-64-54A or 1-Ll-64-66 [3] IF the Drywell Temperature has changed by 2°F or more, THEN PERFORM the calculation using Section B for Drywell and enter the result in column (8) of Section A. (Otherwise enter "O" (Zero) for the calculation.) [4] IF the Suppression Chamber Air Temperature has changed by 2°F or more, THEN PERFORM the calculation using Section C for Suppression Chamber and enter the result in column (9) of Section A. (Otherwise enter "O" (Zero) for the calculation.) [5] Calculate the Total Correction Factor as follows SUM the Drywell (Column 8) and Suppression Chamber {Column 9) and entering the results in Column (10).

BFN Primary Containment Nitrogen 1-Sl-4. 7.A.2.A Unit 1 Consumption and Leakage Rev.0012 PaQe 20 of 43 NOTES 1 ) A Stopwatch may be used to perform Section 7.3.1.

2)

Nitrogen flow is required to be less than 60 SCFM in accordance with 1-01-64, Primary Containment System Operating Instructions, when performing Section 7.3.1. 7.6 Nitrogen Makeup 7.6.1 - Section A - Nitrogen Makeup Data [1] IF Makeup is from the Nitrogen Storage Tank, THEN PERFORM the following during Nitrogen additions: [1.1] In EVENT column, - RECORD "N2 Tank". [1.2] In column (1 ), - RECORD the time each nitrogen addition begins. [1.3] In column (2), - RECORD the nitrogen makeup duration, in minutes, from the chart of DW/SUPPR CHBR N2 MAKEUP FLOW/PRESS, 1-XR-76-14 on Panel 1-9-3 or from stopwatch. [1.4] In column (3), - RECORD the nitrogen makeup flow in cubic feet per minute as indicated by the Red Pen on DW/SUPPR CHBR N2 MAKEUP FLOW/PRESS, 1-XR-76-14 on Panel 1-9-3. [1.5] CALCULATE the amount of nitrogen, in cubic feet (ft3), added during the run by multiplying column (2) by column (3) and RECORD in column (4). [1.6] CALCULATE the total cumulative nitrogen use in cubic feet for the 24-hour period of this test by adding the latest entry in column ( 4) to the previous cumulative total in column (5) and RECORD the new cumulative total in column (5).

BFN Primary Containment Nitrogen 1-Sl-4. 7.A.2.A Unit 1 Consumption and Leakage Rev.0012 Page 21of43 7.6.1 - Section A - Nitrogen Makeup Data (continued) [2] 1oc1q IF the CAD is cross-tied to Drywell Control Air, THEN PERFORM the following: (REFER TO 1-01-84, Containment Atmosphere Dilution System). [BFPER9soa35J (2.1] In EVENT Column, RECORD "CAD/DCA". [2.2J In Column (1 ), RECORD the time CAD was cross-tied to Drywell Control Air on the CAD/DCA line provided. (2.3] In Column (2), RECORD the duration in minutes that CAD was cross-tied to Drywell control air. [2.4] OBTAIN calculated Total Leakage (CFM) from Site Engineering. [2.5] In Column (3), RECORD the calculated Total Leakage (CFM) obtained from Site Engineering [2.6] CALCULATE the amount of nitrogen added during the period by multiplying columns (2) and (3) and RECORD in column (4). (2.7] CALCULATE the total cumulative nitrogen use in cubic feet for the 24-hour period of this test by adding the latest entry in column ( 4) to the previous cumulative total in column (5) and RECORD the new cumulative total in column (5).

BFN Primary Containment Nitrogen 1-Sl-4.7.A.2.A Unit 1 Consumption and Leakage Rev.0012 Page 22 of 43 7.6.1 - Section A - Nitrogen Makeup Data (continued) NOTES

1)

Measure the CAD addition using a stopwatch.

2)

A separate Event Column is required for each CAD TRAIN if both trains are being used at the same time. [3] IF CAD is aligned to the Containment other than Sections 7.6.1 [2], THEN PERFORM the following for CAD additions: [3.1] In EVENT Column, RECORD "CAD/CONT" [3.2] In column (1 ), RECORD the time each CAD addition begins. [3.3] In column (2), RECORD the CAD addition duration, in minutes from the stopwatch. [3.4] In column (3), RECORD the CAO makeup flow in cubic feet per minute for each CAD train being used: CAD A N2 SYSTEM FLOW O-Fl-84-7/3, CAD A N2 SYSTEM FLOW, on 3-PNL-9-54. OR O-Fl-84-7, CAD LINE A N2 FLOW, on (Unit 1) PNL-9-54 CAD B N2 SYSTEM FLOW O-Fl-84-18/3, CAD B N2 SYSTEM FLOW, on 3-PNL-9-55. OR O-Fl-84-18, CAD B N2 SYSTEM FLOW, on (Unit 1) PNL-9-55. (3.5] CALCULATE the amount of nitrogen, in cubic feet (ft3), added during the run by multiplying column (2) by column (3) and RECORD in column (4). [3.6] CALCULATE the total cumulative nitrogen use in cubic feet for the 24-hour period of this test by adding the latest entry in column (4) to the previous cumulative total in column (5) and RECORD the new cumulative total in column (5).

BFN Primary Containment Nitrogen 1-51-4.7.A.2.A Unit 1 Consumption and Leakage Rev.0012 Page 23of43 7.7 Containment Venting NOTE Drywell/Suppression Chamber Venting Correction Factor are absolute values. (No Negative totals) - Section A - Containment Venting Data using 1-FIC-84-20 (~ In column (1 ), RECORD the time the venting begins. In column (4), RECORD the vent flow rate indicated on PATH A VENT FLOW CONT, 1-FIC-84-20 on Panel 1-9-55. ~ In column (2), RECORD the time the venting ends. In column (3}, RECORD the elapsed venting time in minutes by subtracting column (1) from column (2}. In column (5), RECORD the Drywell Venting Correction Factor by multiplying column (3) by column (4). In column (6), Total Cumulative Correction - RECORD the SUM of the previous event column (6) and the current event column (5).

BFN Primary Containment Nitrogen 1-51-4. 7.A.2.A Unit 1 Consumption and Leakage Rev.0012 Page 24 of 43 NOTES

1)

Alternate Containment Venting Data is performed when 1-FIC-84-20 indication is not available.

2)

It is assumed in 3.6F.6 that the suppression chamber water and atmospheric temperatures are in equilibrium, therefore the use of the average suppression pool water temperature is an acceptable substitute in place of the suppression chamber air temperature. IF SUPP CHBR TEMP,1-TE-64-528 on SUPPRESSION CHAMBER TEMPERATURE/PRESSURE, 1-XR-64-52 (point 1), is unavailable, THEN Suppression Pool Water Temperature, 1-TR-64-161 (Point 10) can be substituted. [BFNPER 607653-002] 7.7.2 - Section A -Alternate Containment Venting Data [1] PRIOR to Venting PERFORM the following using instruments on Panel 9-3: A. In column (1 ), RECORD the time the venting begins and ends. B. In column (2), block Ps1. RECORD the DRYWELL PRESSURE, 1-Pl-64-135 indication. C. In column (3), block Ps2, RECORD the DRYWELL PRESSURE, 1-Pl-64-136 indication.

0.

In column (4), block Ts1 RECORD the Drywell temperature, using 1-Tl-64-52AB or 1-XR-64-50. E. In column (5), block Ps3, RECORD the OW/SUPPR CHBR DIFF PRESS, 1-PDl-64-137 indication. F. In column (6), block Ps4, RECORD the DW/SUPPR CHBR DIFF PRESS, 1-PDl-64-138 indication.

BFN Primary Containment Nitrogen 1-Sl-4. 7.A.2.A Unit 1 Consumption and Leakage Rev.0012 Page 25of43 7.7.2 - Section A-Alternate Containment Venting Data (continued) G. In column (7), block Ts2 RECORD the SUPP CHBR TEMP, 1-TE-64-52B on SUPPRESSION CHAMBER TEMPERATURE/PRESSURE, 1-XR-64-52 (point 1 ). OR IF SUPP CHBR TEMP,1-TE-64-528 on SUPPRESSION CHAMBER TEMPERATURE/PRESSURE, 1-XR-64-52 (point 1 ), is unavailable, THEN Suppression Pool Water Temperature, 1-TR-64-161 (Point 10) can be substituted. [BFNPER 607653-002] [2] AFTER the Venting Event is completed, A. In column (2), block PA1. RECORD the Drywell pressure from DRYWELL PRESSURE, 1-Pl-64-135 indication. B. In column (3), block PA2, RECORD the Drywell pressure from DRYWELL PRESSURE, 1-Pl-064-136 indication. C. In column (4), block TA1 - RECORD the Drywell temperature, 1-Tl-64-52AB or 1-XR-64-50. D. In column (5), block PA3. RECORD the DW/SUPPR CHBR DIFF PRESS, 1-PDl-64-137 indication. E. In column (6), block PA4. RECORD the DW/SUPPR CHBR DIFF PRESS, 1-PDl-64-138 indication. F. In column (7), block TA, RECORD the SUPP CHBR TEMP,1-TE-64-52B on SUPPRESSION CHAMBER TEMPERATURE/PRESSURE, 1-XR-64-52 (point 1 ). OR IF SUPP CHBR TEMP,1-TE-64-528 on SUPPRESSION CHAMBER TEMPERATURE/PRESSURE, 1-XR-64-52 (point 1 ), is unavailable, THEN Suppression Pool Water Temperature, 1-TR-64-161 (Point 10) can be substituted. [BFNPER 607653-002]

BFN Primary Containment Nitrogen 1-Sl-4. 7.A.2.A Unit 1 Consumption and Leakage Rev.0012 PaQe 26of43 7.7.2 - Section A -Alternate Containment Venting Data (continued) G. In column (8), block LA, RECORD the SUPPR POOL WATER LEVEL, 1-Ll-64-54A. (Use 1-Ll-64-66if1-Ll-64-54A is INOP.) H. In column (9), - CALCULATE the DRYWELL VENTING CORRECTION using the Orywell Venting Correction Formula in Section C. I. In column (10), - CALCULATE the SUPPRESSION CHAMBER VENTING CORRECTION using the Suppression Chamber Venting Correction Formula in Section C. J. In column (11 ), - RECORD the sum the ORYWELL VENTING CORRECTION Column (9) and SUPPRESSION CHAMBER VENTING CORRECTION Column (10). 7.7.3 Section B Alternate Containment Venting Correction [1] At the completion of the 24-hour period In column (12) - RECORD the Total Venting Correction, Attachment 6, Section B by ADDING all the TOTAL VENTING CORRECTION from Section A, Column (11 ).

BFN Primary Containment Nitrogen 1-Sl-4. 7.A.2.A Unit 1 Consumption and Leakage Rev.0012 Page 27 of 43 7.8 Average Nitrogen Consumption and Leakage 7.8.1 - Section A - Net Nitrogen Leakage [1] Total Drywell Control Air Leakage, - RECORD the Total Drywell Control Air Leakage from Attachment 2 Section A in the Gas Addition to the Drywell table. [2] Cumulative Nitrogen Makeup, - RECORD the total cumulative nitrogen makeup from Attachment 4 Section A in the Gas Addition to the Drywell table. [3] CALCULATE the Total Gas Addition as follows: ADD all the Gas addition types together from the Gas Addition table and RECORD the sum as the Total Gas Addition in the Gas Addition to the Drywell Table. [4] Total Drywell and Suppression Chamber Temperature Correction, - RECORD the TOTAL VENTING CORRECTION from Attachment 3, Section A in the Correction Factor table. [5] Total Suppression Chamber Level Correction - RECORD the total Suppression Chamber level correction from Attachment 1, Section A in the Correction Factor table. [6] Total Venting Correction using 1-FIC 84-20, - RECORD the total Drywall Venting Correction from Attachment 5, Section A in the Correction Factor table [7] Total Alternate Venting Correction, - RECORD the total Drywall Venting Correction from Attachment 6, Section Bin the Correction Factor table. [8] CALCULATE the Correction Factor as follows ADD all the Correction Factor Types together from the Correction Factor Table and RECORD the sum as the Total Correction Factor in the Correction Factor table. [9] CALCULATE the Net Nitrogen Leakage as follows Total Gas Addition for the Net Nitrogen Leakage and SUBTRACT the Air Temperature calculation and SUBTRACT the Total Correction Factor.

BFN Primary Containment Nitrogen 1-51-4. 7.A.2.A Unit 1 Consumption and Leakage Rev.0012 Paae 28 of 43 7.8.2 - Section B -Average Nitrogen Leakage NOTE Leakage rates, for comparison purposes, should always be converted to standard flow rate conditions (flow at 70°F, one standard atmosphere). Since nitrogen gas is supplied by evaporating liquid nitrogen and heating it to approximately 70°F then reducing the pressure to 2.0 psig the conversion is:

14. 7psia + 2.0psig x 460°R + 70°F = I.136 Where:

14.7psia 460°R + 70°F

14. 7 psia = 1 standard atmosphere 2.0 psig = nitrogen supply pressure 460°R = Fahrenheit to Rankine conversion factor 70°F = degrees Fahrenheit of nitrogen, actual and standard For calculation purposes, a day consist of 24-hours. During the days when the time changes to Daylight Savings Time (OST) 23-hours will be used. When returning to Central Standard Time (CST) 25-hours will be used.

To average the net nitrogen usage (in ft3>for a day, a 24 hour period is normally used and the result are expressed in standard cubic feet per hour. The net nitrogen leakage is multiplied by a conversion factor 1.136, then divided by the number of hours in the day. The result gives the average nitrogen leakage in standard cubic feet per hour for that day. When Daylight Savings Time and Central Standard Time changes take place, the appropriate number of hours will be used instead of 24 (hours). [1] MULTIPLY the net nitrogen leakage from Attachment 7, Section A, (Nitrogen Leakage table) by (1.136/Hours during the day). [2] RECORD the result on the Average Nitrogen Leakage line.

BFN Primary Containment Nitrogen 1-Sl-4.7.A.2.A Unit 1 Consumption and leakage Rev.0012 Page 29 of 43 Date / 0 / Z /;y 7.9 Completion and Notifications [1] On the Surveillance Task Sheet (STS), [1.1] RECORD the Completion Date & Time. [1.2] REVIEW and COMPLETE the Surveillance Task Sheet (STS) through the Test Director/lead Performer & Date fields. [2] NOTIFY the Unit Supervisor that this Surveillance Instruction is complete. 8.0 ILLUSTRATIONS/ATTACHMENTS : Suppression Chamber Water Level : Drywell Control Air Leakage : Containment Air Temperature Correction : Nitrogen Makeup Correction : Containment Venting Corrections : Alternate Venting Corrections : Average Nitrogen Consumption and Leakage

BFN Unit 1 Primary Containment Nitrogen Consumption and Leakage (Page 1 of 1) 1-Sl-4. 7.A.2.A Rev.0012 Page 30 of 43 Suppression Chamber Level Correction Date / 0 /z /Ii 1.0 SUPPRESSION CHAMBER LEVEL CORRECTION DATA NOTES

1)

If both Instruments are Operable, then calculate the average of BOTH Operable Instruments by Dividing the sum of their SUPPRESSION CHAMBER LEVEL CORRECTION (column 5) by 2 (two) and record as the TOTAL SUPPRESSION CHAMBER LEVEL CORRECTION.

2)

If one of the instruments is INOP, then use only the Operable Instrumentation Correction Factor for the TOTAL SUPPRESSION CHAMBER LEVEL CORRECTION. A. Suppression Chamber Level Correction Data (Section 7.3.1) (1) (2) (3) (4) (5) Initial Ending Suppr Chbr Suppr Chbr Suppr Chbr Change in Conversion Level Level (IN.) LEVEL (IN.) Suppr Chbr Factor Correction Instrument (0000 Hours) (2400 Hours) Level (IN.) 909.8 FT3/IN. (FT3) 1-Ll-64-54A -s~3 = x 909.8 = 1-Ll-64-66 - 'i.o = x 909.8 = B. Total Suppression Chamber Level Correction Calculation (Section 7.3.2) Column 5(ft3) Column 5(ft3) + for 1-Ll-64-54A for 1-Ll-64-66


= Average Suppression Chamber Level 2

(fl3) (ft3) + 1-LI-64-54A l-LI-64-66 = ___ (ft3) 2 uo INIT uo

BFN Unit 1 Primary Containment Nitrogen Consumption and Leakage (Page 1 of 1) Drywell Control Air Leakage 1-Sl-4.7.A.2.A Rev.0012 Page 31of43 Date Jo/ :Z. /;lj A. Drywell Control Air Leakage (Section 7.4) Drywell Control Air Line A FLOW OW CONT AIR TO X-50, 1-FIQ-032-0092 (1) (2) (3) ENDING (2400 hours} (FT) INITIAL (0000 hours) Drywell Control Air Line B Flow = DW CONT AIR TO X-22, 1-FIQ-032-0075 Difference (1) (2) (3) ENDING (2400 hours) (FT) INITIAL (0000 hours) 317130 Drywell Control Air Leakage 1-FIQ-032-0092 1-FIQ-032-0075 Difference (Column 3) + Difference (Column 3) Difference = Total = uo

BFN Unit 1 Primary Containment Nitrogen Consumption and Leakage (Page 1 of 4) 1-Sl-4.7.A.2.A Rev.0012 Page 32 of 43 Containment Air Temperature Correction Date /_:, / 2/1 I NOTES

1)

If Drywell Temperature changed less than 2 °F, enter zero (0) in Column 8.

2)

If Suppression Chamber Air Temperature changed less than 2 °F, enter zero (0) in Column 9

3)

Drywell/Suppr~ssion Chamber Venting Correction Factor are absolute values. (No Negative totals)

4)

Drywell Temperature can be obtained using 1-Tl-64-52AB or 1-XR-64-50.

5)

It is assumed in 3.6F.6 that the suppression chamber water and atmospheric temperatures are in equilibrium, therefore the use of the average suppression pool water temperature is an acceptable substitute in place of the suppression chamber air temperature. IF SUPP CHBR TEMP,1-TE-64-528 on SUPPRESSION CHAMBER TEMPERATURE/PRESSURE, 1-XR-64-52(point1), is unavailable, THEN Suppression Pool Water Temperature, 1-TR-64-161 (Point 10) can be substituted. [BFNPER 607653-0021

BFN Unit 1 A. Drywell and Suppression Chamber Data Primary Containment Nitrogen Consumption and Leakage (Page 2 of 4) 1-Sl-4. 7.A.2.A Rev.0012 Page 33 of 43 Containment Air Temperature Correction Date 10/2/1( DRYWELL Differential Suppression Chamber 0000 hours 2400 hours Pressure Temp (°F) Pressure (1) (2) (3) (4) (5) 1-Tl-64-52AB 1-Pl-64-135 1-Pl-64-136 or 1-PDl-64-137 1-PDl-64-138 (psig) (psig) Pu1 /, LJO Pe.i J.3b PAI PA.2 (8) DRYWELL VENTING CORRECTION FT3 + 1-XR-64-50 Tu, J ~ { TAI (9) SUPRESSION CHMBR VENTING CORRECTION (psid) Pro /, 1._7 p"' FT3 = (psid) Pu* /, 2._ ~ p,.. (10) Total VENTING CORRECTION FT 3 Air Temp Level (6) (7) 1-XR-64-52 Point 1 (°F) or 1-TR-64-161 1-Ll-64-54A {Point 10) or66 Tll2 C/lf, 1_ NIA T., LA uo

BFN Unit 1 Primary Containment Nitrogen Consumption and Leakage (Page 3 of 4) 1-Sl-4. 7.A.2.A Rev.0012 Paae 34 of 43 Containment Air Temperature Correction B. Containment Air Temperature Correction

1.

Drywell Air Temperature Correction Equation Drywell Temperature Correction where: Orywell pressure before venting taken from DRYWELL PRESSURE indicator 1-Pl-64-135 Drywell pressure before venting taken from DRYWELL PRESSURE indicator 1-Pl-64-136 Orywell pressure after venting taken from ORYWELL PRESSURE indicator 1-Pl-64-135 Orywell pressure after venting taken from DRYWELL PRESSURE indicator 1-Pl-64-136 Drywell temperature before venting taken from DRYWELL TEMPERATURE indicator 1-Tl-64-52AB or 1-XR-64-50 and corrected to absolute temperature (Rankine) Drywell temperature after venting taken from DRYWELL TEMPERATURE indicator 1-Tl-64-52AB or 1-XR-64-50 and corrected to absolute temperature (Rankine)

BFN Unit 1 Primary Containment Nitrogen Consumption and Leakage (Page 4 of 4) 1-51-4.7.A.2.A Rev.0012 Page 35 of 43 Containment Air Temperature Correction

2.

Suppression Chamber Air Temperature Correction Equation where: P01 Ps2 P03 Ps4 Ts2 + 460 TA2 + 460 = Suppression Chamber Temperature Correction Drywell pressure berore venting taken from ORYWELL PRESSURE indicator 1-Pl-64-135 Drywell pressure before venting taken from DRYWELL PRESSURE indicator 1-Pl-64-136 Drywall/Suppression Chamber differential pressure before venting taken from OW/SUPPR CHBR DIFF PRESS indicator 1-PDl-64-137 Drywall/Suppression Chamber differential pressure before venting taken from OW/SUPPR CHBR DIFF PRESS indicator 1-PDl-64-138 Suppression Chamber temperature before venting taken from SUPPRESSION CHAMBER TEMPERATURE/PRESSURE recorder, (1-XR-64-52 Point 1) OR Suppression Pool Water Temperature, 1-TR-64-161 (Point 10) IF (1-XR-64-52 Point 1) is unavailable and corrected to absolute temperature (Rankine) IBFNPER 60765J.-002J Suppression Chamber temperature after venting taken from SUPPRESSION CHAMBER TEMPERATURE/PRESSURE recorder, 1-XR-64-52 (Point 1) OR Suppression Pool Water Temperature, 1-TR-64-161 (Point 10) IF (1-XR-64-52 Point 1) is unavailable and corrected to absolute temperature (Rankine) tBFNPERso1ssJ.-0021 Drywell pressure after venting taken from DRYWELL PRESSURE indicator 1-Pl-64-135 Drywell pressure after venting taken from DRYWELL PRESSURE indicator 1-Pl-64-136 = Drywell/Suppression Chamber differential pressure after venting taken from DW/SUPPR CHBR DIFF PRESS indicator 1-PDl-64-137 Drywall/Suppression Chamber differential pressure after venting taken from DW/SUPPR CHBR DIFF PRESS indicator 1-PDl-64-138 Suppression Chamber water level taken from SUPPR POOL WATER LEVEL indicator 1-Ll-64-54A or 66.

BFN Unit 1 Primary Containment Nitrogen Consumption and Leakage (Page 1 of 1) 1-Sl-4. 7.A.2.A Rev.0012 Page 36 of 43 Nitrogen Makeup/Suppression Chamber Level A. Nitrogen Makeup Data (Section 7.6.1)

1.
2.
3.
4.
5.
6.
7.

8 EVENT Remarks: ( 1) TIME (2) MAKEUP DURATION (MINUTES) x x x x x x x x (3) N2MAKEUP FLOW (CFM) = = = = = = = = (4) N2 ADDED (2) x (3) (FT3) Date /o /z./1r (5) CUMULATIVE N2 MAKEUP (4) +PREVIOUS (5) (FT3) UNIT OPER INITIAL

BFN Primary Containment Nitrogen 1-Sl-4. 7.A.2.A Unit 1 Consumption and Leakage Rev.0012 Page 37 of 43 (Page 1 of 1) Containment Venting Correction Date !0/2/ ;y A. Venting Data using 1-FIC 84-20, NOTES

1)

Enter data for each venting event: (ie. flow started and stopped through vent valves)

2)

Drywell/Suppression Chamber Venting Correction Factor are absolute values. (No Negative totals) EVENT Calculations ( 1) (2) (3) (4) (5) {6) ELAPSED Event Total VENT FLOW RATE Total Cumulative START END TIME 1-FIC-84-20 (SCF) Correction uo TIME TIME (MIN) (SCFM) (Note 1) (Note2) 1 2322 2~35 13 /OD /]DO !}oo so 2 13'-IZ 135,;- I 2, /OD /3 cro 2/:,Do -SD 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Note 1 Column (3) x Column (4) Note 2 Previous Event Column (6) + Current Event Column (5)

BFN Primary Containment Nitrogen 1-Sl-4. 7.A.2.A Unit 1 Consumption and Leakage Rev.0012 Page 38 of 43 (Page 1 of 4) Alternate Venting Correction Date /o/z/;y NOTES

1)

Alternate Containment Venting Data is performed when 1-FIC-84-20 indication is not available.

2)

In this table the BEFORE is prior to establishing flow through the vent valves.

3)

The AFTER is when venting is completed, regardless of the number of times for the event. It can also be taken either before or after the DP Air Compressor pumps up the drywell, but do not take data while the DP is running.

4)

Use 1-Ll-64-54A unless INOP then use 1-Ll-64-66.

5)

Drywell/Suppression Chamber Venting Correction Factor are absolute values. (No Negative totals)

6)

It is assumed in 3.6F.6 that the suppression chamber water and atmospheric temperatures are in equilibrium, therefore the use of the average suppression pool water temperature is an acceptable substitute in place of the suppression chamber air temperature. IF SUPP CHBR TEMP,1-TE-64-528 on SUPPRESSION CHAMBER TEMPERATURE/PRESSURE, 1-XR-64-52 (point 1), is unavailable, THEN Suppression Pool Water Temperature, 1-TR-64-161 (Point 10) can be substituted. [BFNPER607653-002i

BFN Unit 1 Primary Containment Nitrogen Consumption and Leakage (Page 2 of 4) Date A. Alternate Venting Data (Section 7.7.2) DRYWELL Pressure Temp (°F) (1) (2) (3) (4) 1-Tl-64-52AB 1-Pl-64-135 1-Pl-64-136 or EVENT TIME (psig) (psig) 1-XR-64-50 (BEFORE) Pa1 Pai To1 1 (AFTER) PA, PAZ T.. (BEFORE) Ps1 pill Ta1 2 (AFTER) PA, PAZ TA, (BEFORE) Pu1 PEil Ts1 3 (AFTER) PA1 PA2 T., (BEFORE) Pa1 PEil Tu1 4 (AFTER) PA1 PA2 TA1 (BEFORE) Pu, pll2 To1 5 (AFTER) PA1 p"' TA, 1-Sl-4.7.A.2.A Rev.0012 Page 39 of 43 /o/2/1y Differential Suppression Chamber Pressure Air Temp Level (5) (6) (7) (8) 1-XR-64-52 Point 1(°F) or 1-PDl-64-137 1-PDl-64-138 1-TR-64-161 1-Ll-64-54A (psid) (psid) (Point 10) or66 PUJ P,.. Tll2 NJA PAJ PA. T"" LA P,., Pa* Tai NJA PAJ PM TA2 LA P.,, P,.. Tai NJA PAJ PM TA2 LA pill P,.. Tw NJA PAJ P,... T.., LA pill pa.< Tai N/A PAJ P,,. TA2 LA

2 3 4 5 B. BFN Unit 1 (9) ORYWELL VENTING CORRECTION Primary Containment Nitrogen ft3 ft3 ft3 ft3 ft3 Consumption and Leakage + + + + + (Page 3 of 4) (10) SUPRESSION CHMBR VENTING CORRECTION ft3 ft3 ft3 ft3 ft3 = = = = = Total Alternate Venting Correction 1-51-4. 7.A.2.A Rev.0012 PaQe 40 of 43 Date (11) TOTAL VENTING CORRECTION ft3 ft3 ft3 ft3 ft3 Sum all of the Total Venting Corrections from Section A, Column 11 (12) TOTAL VENTING CORRECTION FT3 uo Initial /o Jz/1<-1 uo Initials

BFN Primary Containment Nitrogen 1-51-4.7.A.2.A Unit 1 Consumption and Leakage Rev.0012 (Page 4 of 4) Page 41 of 43 C. Alternate Venting Correction Formulas( Section 7.7.2)

1.

Drywell Correction Equation 1-t 7.,.. where: < (T" *.11\\0 ) ix 159000 , x (T,., + *l60 ) 1 P01 Ps2 PA1 P,\\2 T B1+460 TA1+460 Drywall Temperature Correction Drywetl pressure before venting taken from DRYWELL PRESSURE indicator 1-Pl-64-135 Drywall pressure before venting taken from DRYWELL PRESSURE indicator 1-Pl-64-136 Drywall pressure after venting taken from DRYWELL PRESSURE indicator 1-Pl-64-135 Drywell pressure after venting taken from DRYWELL PRESSURE indicator 1-Pl-64-136 Drywall temperature before venting taken from DRYWELL TEMPERATURE indicator 1-Tl-64-52AB or 1-XR-64-50 and corrected to absolute temperature (Rankine) Drywell temperature after venting taken from DRYWELL TEMPERATURE indicator 1-Tl-64-52AB or 1-XR-64-50 and corrected to absolute temperature (Rankine)

2.

Suppression Chamber Correction Equation where: P01 Ps2 P03 Pe4 T02 + 460 TA2 + 460 = - [(L, + I)>< 909.8 IJ = Suppression Chamber Temperature Correction Drywetl pressure before venting taken from DRYWELL PRESSURE indicator 1-Pl-64-135 Drywetl pressure before venting taken from DRYWELL PRESSURE indicator 1-Pl-64-136 Drywall/Suppression Chamber differential pressure before venting taken from DW/SUPPR CHBR DIFF PRESS indicator 1-PDl-64-137 Drywall/Suppression Chamber differential pressure before venting taken from DW/SUPPR CHBR DIFF PRESS indicator 1-PDl-64-138 Suppression Chamber temperature before venting taken from SUPPRESSION CHAMBER TEMPERATURE/PRESSURE recorder, (1-XR-64*52 Point 1) OR Suppression Pool Water Temperature, 1-TR-64-161(Point10) IF (1-XR-64-52Point1) is unavailable and corrected to absolute temperature (Rankine) lBFNPER 001es:J.0021 Suppression Chamber temperature after venting taken from SUPPRESSION CHAMBER TEMPERATURE/PRESSURE recorder, 1-XR-64-52 (Point 1) OR Suppression Pool Water Temperature. 1-TR-64-161 (Point 10) IF (1-XR-64-52 Point 1) is unavailable and corrected to absolute temperature (Rankine) lBFNPER 607653.0021 Drywell pressure after venting taken from DRYWELL PRESSURE indicator 1-Pl-64-135 Drywell pressure after venting taken from DRYWELL PRESSURE indicator 1-Pl-64-136 = Drywell/Suppression Chamber differential pressure after venting taken from DW/SUPPR CHBR DIFF PRESS indicator 1-PDl-64-137 Drywall/Suppression Chamber differential pressure after venting taken from DW/SUPPR CHBR DIFF PRESS indicator 1-PDl-64-138 Suppression Chamber water level taken from SUPPR POOL WATER LEVEL indicator 1-Ll-64-54A or 66.

BFN Unit 1 Primary Containment Nitrogen Consumption and Leakage (Page 1 of 2) 1-51-4.7.A.2.A Rev.0012 Page 42 of 43 Average Nitrogen Consumption and Leakage Date / 0 / 2 ) I Y A. Net Nitrogen Leakage (Section 7.8)

1.

SUM all Gas additions to obtain the Total Addition: Gas Addition to the Drywell Total Drywell Control Air Leakage ft3 Attachment 2, Section A Cumulative Nitrogen Makeup + ft3 Attachment 4, Section A Total Gas Addition = ft3

2.

Air Temperature Correction Air Temperature Total DW and SC Temperature Correction I ft3 Attachment 3, Section A

3.

SUM all the Correction Factors to obtain a Total Correction Factor: Correction Factor Total Supp Chamber Level Correction ft3 Attachment 1, Section B Total Venting Correction using 1-FIC 84-20 ft3 Attachment 5, Section A Total Alternate Venting Correction + ft3 Attachment 6, Section B Total Correction Factor = ft3

4.

CALCULATE Net Nitrogen leakage: Total Gas Addition - Total DW and SC Tempe Correction - Total Correction Factor Nitrogen Leakage Total Gas Addition ft3 (Step 1 above) Total DW and SC Temperature Correction ft3(Step 2 above) Total Correction Factor ft3(Step 3 above) Net Nitrogen Leakage = ft3

BFN Unit 1 Primary Containment Nitrogen Consumption and Leakage (Page 2 of 2) 1-51-4. 7.A.2.A Rev.0012 Paae 43 of 43 Average Nitrogen Consumption and Leakage Date /o /2 /1+/- NOTES

1)

For calculation purposes, a day consist of 24-hours. During the days when the time changes to Daylight Savings Time (DST) 23-hours will be used. When returning to Central Standard Time (CST) 25-hours will be used.

2)

The average nitrogen leakage (adjusted) must be <542 SCFH (Step 6.0A.1 ). NOTIFY the Unit Supervisor (US) if the nitrogen leakage exceeds 542 SCFH (REFER TO 1-AOl-64-7 and Tech Specs 3.6.1.1 ). B. Average Nitrogen Leakage (Section 7.8.2) Calculate the Average Nitrogen Leakage \\ N. L k Net nitrogen leakage x I. L 36 , vg. 1trogen ea age= = Hours during the day Avg. Nitrogen Leakage= ( __ Hours) Avg. Nitrogen Leakage----SCFH (AC) (AC) uo IV

IUSll Job Performance Measure (JPM) SITE: I BFN JPM TITLE: Perform a Loss of Safety Function Determination JPM NUMBER: 633 REVISION: I 0 TASK

  • SRO D STA DUO D NAUO APPLICABILITY:

TASK NUMBER /TASK TITLE(S):I S-000-AD-27; Ass~ss LCO/TRM Actions Required for Inoperable Equipment KIA RATINGS: JSRO 4.7 KIA STATEMENT: \\ ~.2.. ~5 - Kno~_ledge of the b~ses in Technica! ~pecification for hm1tmg conditions for operations and safety hm1ts. RELATED PRA INFORMATION:/ N/A SAFETY FUNCTION: J Admin - Equipment Control EVALUATION LOCATION: D In-Plant D Simulator ID Control Room I D Lab

  • Other - List Classroom APPLICABLE METHOD OF TESTING: 0 Discussion 0 Simulate/Walkthrough
  • Perform TIME FOR COMPLETION: NA TIME CRITICAL (Y/N)N ALTERNATE PATH (Y/N) N Developed by:

Developer Date (Ensure validator is briefed on exam security per NPG-SPP-17.8.1) (See JPM Validation Checklist in NPG-SPP-17.8.2) Validated by: Validator Date Approved by: Site Training Management Date Approved by: Site Training Program Owner Date 1

I llll I Job Performance Measure (JPM) OPERATOR: JPM Number 633 SRO DATE: --- TASK STANDARD: Performs a Loss of Safety Function Evaluation for the inoperable equipment in accordance with OPDP-8 Attachment 7 Step 3.1, Initiating an LOSF Evaluation. PRA: NA REFERENCES/PROCEDURES NEEDED: OPDP-8 - Safety Function Determination Program (SFDP) BFN Only. Unit 2 Tech Specs VERIFICATION TIME: 20 Min PERFORMANCE TIME: COMMENTS: ------------------------ Additional comment sheets attached? YES NO RESULTS: SATISFACTORY UNSATISFACTORY SIGNATURE: DATE: EXAMINER 2 (Retain entire JPM for records)

I ii11 I Job Performance Measure (JPM) CLASSROOM: INITIAL CONDITIONS: Units 1 and 3 are at 100% power. Unit 2 is at 40% power with 2-GOl-100-1A Unit Startup and Power Operation in progress following a refueling outage. The B Train of Standby Gas Treatment (SGT) is INOP for scheduled maintenance and is in day 2 of a planned 5 day outage. All LCO actions were taken. Subsequently, The IM Forman reports that review of: 2-SR-3.3.1.1.13(4A) and 2-SR-3.3.1.1.13(4C) Reactor Protection and Primary Containment Isolation Systems Low Reactor Water Level Instrument Channel A 1 (A2) Calibration (2-L-3-203A) and (2-L-3-203C), indicate that 2-LIS-3-203A and 2-LIS-3-203C were calibrated incorrectly and that they would not produce a trip output until Reactor Water Level lowered to (-) 10 inches. The appropriate Tech Spec LCO(s) were entered. INITIATING CUE: The Shift Manager directs you to perform a Loss of Safety Function Determination. 3

I UEI Job Performance Measure (JPM) START TIME ___ STEP/STANDARD SAT I UNSAT Step 1: A. Upon determining that a SSC is in a degraded or nonconforming condition and has been declared inoperable, an LOSF evaluation shall be initiated. A flow chart of the process is depicted in Figure 1.

8. Determine if the inoperable SSC is directly addressed by a TS LCO.

If the SSC is addressed in TS, then go to Step 3.1 D, otherwise continue with Step C. C. If the inoperable SSC is not addressed in TS, then determine if it renders another SSC directly addressed in TS inoperable. If the initially inoperable SSC does not render a SSC addressed in TS SAT inoperable, then no further action is required, and no further LOSF evaluation is required. UN SAT D. Enter the applicable TS Conditions and Required Actions for the N/A inoperable TS SSCs determined in Steps 3.18 and/or 3.1 C, above. Standard: Evaluates Step 3. 1 A and determines a LOSF Evaluation shall be initiated. Determines the inoperable SSC is directly addressed by a TS LCO and continues to step 3.1.D. Determines that step C is N/A and continues to step D. NOTE: the initial conditions state The appropriate Tech Spec LCO(s) were entered. 4

I n!D I Job Performance Measure (JPM) STEP/STANDARD Step 2: E. Determine if any active LCO applies to any of the Support System(s) listed on Attachment 1. Standard: SAT I UNSAT Critical Step _SAT Determines that the Support Systems from Attachment 1 is LCO _UNSAT 3.3.6.1, PCIS INSTRUMENTATION _N/A 3.3.6.2, SECONDARY CONTAINMENT INSTRUMENTATION. And continues at step F. Step 3: F. Using Attachment 1, determine all Supported System(s) associated with the Support Systems identified in Step 3.1 E. (The identified supported system may in turn also be a support system in which case this evaluation would need to be repeated.) Standard: Determines the Supported Systems associated with the Support Critical Step _SAT _UNSAT System identified in Step 3.1 E are _N/A LCO 3.6.1.3 PCIVs LCO 3.6.4.2 SCIVs LCO 3.6.4.3 SGTs. Step 4: G. Do any current inoperabilities exist against the Supported Systems identified in Step 3.1 F? If no, no further evaluations are required. If yes, go to Step 3.1 H. Standard: Determines that current inoperabilities exist against the Supported Systems identified in Step 3.1 F (SGT) Answers yes, and goes to Step 3.1 H. 5 Critical Step _SAT _UNSAT _N/A

I U!DI Job Performance Measure (JPM) STEP/STANDARD Step 5: H. Review Attachment 2 to determine if an LOSF exists. If no LOSF exists, then no further actions are required. If an LOSF exists, then go to Step 3.11. Standard: Reviews Attachment 2 and determines a LOSF exists because, SAT I UNSAT Critical Step _SAT _UNSAT for Tech Spec 3.3.6.2, Function1 (Reactor Low Level), loss of all _N/A required channels in a trip system OR for Tech Spec 3.6.4.3, (Standby Gas Treatment System) two or more SGT subsystems inoperable. STOP TIME __ END OF TASK 6

liml Job Performance Measure (JPM) Provide to Applicant INITIAL CONDITIONS: Units 1 and 3 are at 100% power. Unit 2 is at 40% power with 2-GOl-100-1A Unit Startup and Power Operation in progress following a refueling outage. The 8 Train of Standby Gas Treatment (SGT) is INOP for scheduled maintenance and is in day 2 of a planned 5 day outage. All LCO actions were taken. Subsequently, The IM Forman reports that review of: 2-SR-3.3.1.1.13(4A) and 2-SR-3.3.1.1.13(4C) Reactor Protection and Primary Containment Isolation Systems Low Reactor Water Level Instrument Channel A1 (A2) Calibration (2-L-3-203A) and (2-L-3-203C), indicate that 2-LIS-3-203A and 2-LIS-3-203C were calibrated incorrectly and that they would not produce a trip output until Reactor Water Level lowered to(-) 10 inches. The appropriate Tech Spec LCO(s) were entered. INITIATING CUE: The Shift Manager directs you to perform a Loss of Safety Function Determination. 7

liml Job Performance Measure (JPM) SITE: I BFN JPM TITLE: Review a Radiological Survey Map JPM NUMBER: 544 REVISION: 12 TASK

  • SRO D STA
  • uo D NAUO APPLICABILITY:

TASK NUMBER I TASK TITLE(S):I A-000-AD-35 /Use a Radiation Work Permit KIA RATINGS: I 2.3.7 KIA RATING: RO 3.5 SRO 3.6 KIA STATEMENT: I Ability to comply ~i~h radiation work permit requirements during normal or abnormal cond1t1ons. RELATED PRA INFORMATION:! N/A SAFETY FUNCTION: IN/A EVALUATION LOCATION: D In-Plant D Simulator ID Control Room I D Lab

  • Other - List Classroom APPLICABLE METHOD OF TESTING: 0 Discussion 0 Simulate/Walkthrough
  • Perform TIME FOR COMPLETION:

N/A TIME CRITICAL (Y/N) N ALTERNATE PATH (Y/N) N Developed by: Developer Date (Ensure validator is briefed on exam security per NPG-SPP-17.8.1) (See JPM Validation Checklist in NPG-SPP-17.8.2) Validated by: Validator Date Approved by: Site Training Management Date Approved by: Site Training Program Owner Date 1

llml Job Performance Measure (JPM) JPM Number 544 RO SRO DATE: --- TASK STANDARD: Review a Radiological Survey Map to determine if a task can be completed without exceeding exposure limits PRA: NA REFERENCES/PROCEDURES NEEDED: None VALIDATION TIME: 10 Minutes PERFORMANCE TIME: COMMENTS: ------------------------ Additional comment sheets attached? YES NO RESULTS: SATISFACTORY UNSATISFACTORY SIGNATURE: DATE: EXAMINER 2 (Retain entire JPM for records)

IUEI Job Performance Measure (JPM) Classroom INITIAL CONDITIONS: You are a Browns Ferry employee who has obtained a cumulative yearly dose of 850 mrem. The job will require you to vent the RWCU Regenerative Hx and to manually close the 3-FCV-69-2 (RWCU OUTBD SUCT ISOLATION) valve and place a mechanical restraining device on the valve. You are expected to stay at the vent valve the entire duration of the vent and will require 30 minutes for venting. Then proceed to 3-FCV-69-2 (RWCU OUTBD SUCT ISOLATION) valve to manually close and install the mechanical restraining device, it will require 10 minutes to close the valve and another 10 minutes to install the mechanical restraining device. The map of the room has radiological survey information you must interpret to successfully complete this JPM. Assume the 30cm reading will be the whole body dose rate received at each location. Assume that any transit time has NO dose. INITIATING CUE: Given the following survey map, DETERMINE if you can complete the assigned task in the area without exceeding limits. 3

I U!l I Job Performance Measure (JPM) ANSWER: Hx Vent at 30 min 30/60 =.5 hrs .5 x 250 = 125 mrem to vent Hx EXAMINER KEY 10 min to close valve + 10 min to install device = 20 min 20160 =. 33 hrs .33 x 100 = 33.3mrem to close valve & install device 125 + 33.3 = 158.3 (Between 155.0 to 160.0) (Critical) 158.3 + 850 = 1008.3 (NO - not within TVA annual limit of 1 Rem) (Critical) Work areas at 30cm dose rate 250 & 100 are both < 500mrem rate alarm 4

llml Job Performance Measure (JPM) Provide to Applicant Classroom INITIAL CONDITIONS: You are a Browns Ferry employee who has obtained a cumulative yearly dose of 850 mrem. The job will require you to vent the RWCU Regenerative Hx and to manually close the 3-FCV-69-2 (RWCU OUTBD SUCT ISOLATION) valve and place a mechanical restraining device on the valve. You are expected to stay at the vent valve the entire duration of the vent and will require 30 minutes for venting. Then proceed to 3-FCV-69-2 (RWCU OUTBD SUCT ISOLATION) valve to manually close and install the mechanical restraining device, it will require 10 minutes to close the valve and another 10 minutes to install the mechanical restraining device. The map of the room has radiological survey information you must interpret to successfully complete this JPM. Assume the 30cm reading will be the whole body dose rate received at each location. Assume that any transit time has NO dose. INITIATING CUE: Given the following survey map, DETERMINE if you can complete the assigned task in the area without exceeding limits. 5

I [I!] I Job Performance Measure (JPM) Provide to Applicant BROWNS FERRY NUCLEAR PLANT Unit: 3 Permit Number: Training Page: 1 RADIOLOGICAL WORK PERMIT BRIEFING REQUIRED EVERY ENTRY GENERAL DESCRIPTION Status: Active Start Date: 01-Jan-This year End Date: 01-Jan-Next year Type: SPECIFIC MAP ID: Outage: Y Name: Task: ROUTINE PLANT MAINTENANCE PSE: N HP CONTINUOUS Authorization Type: INDIVIDUAL ALARA Review Number: OA-0010 Primary Work Doc: Person-mrem Estimate: 1904 Person-Hrs Estimate: 1082 Dose Alarm: 200 Dose Rate Alarm: 500 DAC-Hrs Tracked: N Work Area

Description:

Unit 3 Areas All Elevations DESCRIPTION OF WORK TO BE PERFORMED I Unit 3 Maintenance on RWCU (69) Systems (LHRA VARIOUS DRESS) 200/2501500 ANTI-CONTAMINATION CLOTHING REQUIREMENTS 1 LAB COAT 1,2 BOOTIES, CLOTH, ONE PAIR 1,2 GLOVES, RUBBER, ONE PAIR 1,2,3 CLOTH INSERTS 1,2,3 SHOE COVERS, ONE PAIR 1,2,3 MODESTY CLOTHING 1,2,3 NO PERSONAL OUTER CLOTHING 1,2,3 SURGEON'S CAP 2,3 COVERALLS, ONE PAIR 3 BOOTIES, PLASTIC, TWO PAIR 3 FACE SHIELD 3 RAIN SUIT 3 GLOVES, RUBBER, TWO PAIR 3,4 HOOD DOSIMETRY REQUIREMENTS I ELECTRONIC DOSIMETER I TLD BRIEFING REQUIREMENTS I PRE-JOB BRIEFING EQUIS WORK STEPS 1 MANAGEMENT I WO WALKDOWN 2 3-Cl-412 3 OPS VALVE LINEUP 01-69 & HX VENTING 4 07 -712928-000 5 06-722560-000 6

I ii!! I Job Performance Measure (JPM) Provide to Applicant BROWNS FERRY NUCLEAR PLANT Unit: 3 Permit Number: Training Page: 1 RADIOLOGICAL WORK PERMIT BRIEFING REQUIRED EVERY ENTRY WORKER INSTRUCTIONS 1 DRESSOUT CODE APPLICATIONS

1) FLOOR LEVEL INSP, LOW TO MODERATE CONTAMINATION.
2) MINOR MAINTENANCE, NO PRIMARY SYSTEM BREACH.
3) PRIMARY SYSTEM BREACH, HEAT EXCHANGER VENTING.
4) ANY WORK ABOVE FLOOR LEVEL REQUIRES SAFETY BELT W/ LIFELINE.
5) REQUIRED TO WEAR HEADGEAR OTHER THAN PERSONAL HARDHAT.

2 MONITOR YOUR ED (DAD) FREQUENTLY, EXIT THE AREA PRIOR TO REACHING THE DOSE ALARM SET POINT OR UPON RECEIVING ANY UNEXPECTED ALARMS. 3 DO NOT EXCEED 250 mrem PER ENTRY OR DOSE MARGIN (RAD-REMAINING ALLOWABLE DOSE). 4 REMOTE MONITORING, PEA, OR SIMILAR DEVICE REQUIRED. 5 ED (DAD) TO BE BAGGED (WRAPPED) AND WORN OUTSIDE OF C-ZONE CLOTHING. 6 REVIEW PLANNED WORK OR INSPECTIONS WITH RAD PROTECTION PRIOR TO ENTRY. 7 UTILIZE TIME, DISTANCE, AND SHIELDING ALARA PRINCIPLES. 8 REVIEW APPROPRIATE SURVEY DATA PRIOR TO ENTRY. NOTE AND AVOID POSTED HOT SPOTS. LOCATE AND UTILIZE LOW DOSE WAITING AREAS. 9 RADWORKER SHALL ADHERE TO ANY SPECIAL INSTRUCTIONS (APR, ETC) ON WHICH HE/SHE HAS BEE~IEFED BY RAD PROTECTION. 10 NOTIFY RADCON PRIOR TO ANY SYSTEM BREACH. 11 RAD PROTECTION COVERAGE MAY BE PROVIDED FROM OUTSIDE THE C-ZONE. 12 SECURE ALL HOSES, ELECTRICAL CORDS, WELDING LEADS AND OTHER SERVICES ENTERING THE C-ZONE AT THE C-ZONE BOUNDRY AND NOTIFY RAD PROTECTION. 13 NOTIFY RAD PROTECTION OF ANY UNUSUAL RADIOLOGICAL CONDITIONS (FOR EXAMPLE: WATER, LEAKS, RADIATION MONITOR ALARMS). 14 RAD PROTECTION PERMISSION REQUIRED PRIOR TO WELDING, GRINDING, BUFFING OR OTHER SURFACE DISTURBING ACTIVITIES. APPROVAL Prepaired by: T JFRANK Approved by: MJHAZEL Final Aooroval: JWSMITH3 End of RWP 7

I UE I Job Performance Measure (JPM) Provide to Applicant Browns Ferry Radlologlcal survey 8 20000 DPM/100 40000 DPM/100 cm2 300000 DPM/100 cm2, 1300000 mradJhrtl 00 cmlli 200000 DPM/100 cm2. 250000 DPM/100 cm2 400000 DPM/100 cm2 80000 DPM/100 cm2 200000 DPM/100 cm2

llml Job Performance Measure (JPM) SITE: BFN JPM TITLE: Classify the event per REP (Uncontrolled water level decrease in SFSP) JPM NUMBER: 621TC REVISION: i 1 TASK

  • SRO D STA DUO D NAUO APPLICABILITY:

TASK NUMBER I TASK TITLE(S):I S-000-EM-21 /Classify and Declare an Abnormal/Emergency Event KIA RATINGS: I 2.4.41 KIA RATING: SRO 4.6 KIA STATEMENT: I Knowledge of the emergency action level thresholds and classifications RELATED PRA INFORMATION:! N/A SAFETY FUNCTION: I NIA EVALUATION LOCATION: D In-Plant D Simulator JD Control Room J D Lab Other - List Classroom APPLICABLE METHOD OF TESTING: 0Discussion 0 Simulate/Walkthrough

  • Perform TIME FOR COMPLETION: 15+15 TIME CRITICAL (Y/N) Y ALTERNATE PATH (Y/N) N Developed by:

Developer Date (Ensure validator is briefed on exam security per NPG-SPP-17.8.1) (See JPM Validation Checklist in NPG-SPP-17.8.2) Validated by: Validator Date Approved by: Site Training Management Date Approved by: Site Training Program Owner Date 1

I [11] I Job Performance Measure (JPM) JPM Number: 621TC RO SRO X DATE: --- TASK STANDARD: The event is classified as an ALERT based on uncontrolled water level decrease in the spent fuel pool with irradiated fuel assemblies expected to result in irradiated fuel assemblies being uncovered PRA: NA REFERENCES/PROCEDURES NEEDED: EPIP-1, EPIP-3 VALIDATION TIME: 15 min. to classify and 15 minutes to complete Appendix A PERFORMANCE TIME: COMMENTS: ------------------------- Additional comment sheets attached? YES NO RESULTS: SATISFACTORY UNSATISFACTORY SIGNATURE: DATE: EXAMINER 2 (Retain entire JPM for records)

llml Job Performance Measure (JPM) CLASSROOM INITIAL CONDITIONS: You are the Shift Manager. Units 1, 2, and 3 were operating at 100% power when Unit 1 received Start of Strong Motion Accelerograph (9-22C, W5) and personnel in the Control Room felt the floor shake. The Condensate makeup valve 2-SHV-078-0532 is danger tagged closed. Unit 2 received Fuel Pool Skimmer Surge Tank Level Lo/Lo-Lo (9-4C, W4). Compensatory hoses connected to demin water connections are not maintaining Fuel Pool level. Unit 2 received Fuel Pool System Abnormal (9-4C, W1) AND Fuel Pool Floor Area Radiation High (9-3A, W1) The Fuel Pool liner is leaking and Fuel Pool level is lowering. Unit 2 entered 2-AOl-78-1, Fuel Pool Cleanup System Failure Loss of Offsite Power occurred and the C and D Diesel Generators failed to start. Unit 2 attempted to restore Fuel Pool level using EECW however, 1-SHV-067-0792 North Header supply to Emergency Fuel Pool Make Up will not open and the South EECW header is depressurized. Unit 2 attempted to align RHRSW to inject to the Fuel Pool; however, 1-FCV-23-57, Standby Coolant valve would not open electrically. The Fuel Pool leak is progressively getting larger and the Fuel Pool level will be at the top of the fuel bundles within 15 minutes. CURRENT CONDITIONS: Reactor Water Level (-) 20 inches and rising Reactor Pressure 650 psig and lowering OW Pressure 1.35 psig and steady OW Temperature 148 °F and steady SP Temperature 115 °F and slowly rising Torus Level +1 inch on narrow range and slowly rising Fuel Pool Level 15 feet below the ventilation duct opening 2-Rl-90-1A Fuel Pool Area El 664 250 mR/HR and slowly rising 2-Rl-90-2A Service Floor Area El 664 200 mR/HR and slowly rising Wind Direction 105° Wind Speed 10 mph O-Sl-4.8.b.1.a.1, Airborne Effluent Release Rate, Release Fraction 0.91 INITIATING CUE: Identify the HIGHEST REQUIRED emergency classification, and complete the required actions. Raise your hand immediately once you have classified the event, and the examiner will provide you with the EPIP associated with the classification you have declared. THIS JPM IS TIME CRITICAL 3

liml Job Performance Measure (JPM) BFN EMERGENCY CLASSIFICATION PROCEDURE EPIP-1 Rev.0049 UnitO EVENT CLASSIFICATION MATRIX PAGE 19 OF 205 Uncontrolled water level decrease in Reactor Cavity with irradiated fuel assemblies expected to remain covered by water. OPERATING CONDITION: Mode5 1 Uncontrolled water level decrease in Reactor Cavity expected to result in irradiated fuel assemblies being uncovered. OPERATING CONDITION: Mode5 Reactor water level can NOT be maintained above -162 inches. (TAF) OPERATING CONDITION: ALL Reactor water level can NOT be restored and maintained above -180 inches. OPERATING CONDITION: Mode 1 or 2 or 3 Uncontrolled water level decrease in Spent Fuel Pool with irradiated fuel assemblies expected to remain covered by water. OPERATING CONDITION ALL Uncontrolled water level decrease in Spent Fuel Storage Pool expected to result in irradiated fuel assemblies being uncovered. OPERATING CONDITION: ALL Key Reactor water level can NOT be determined. OPERATING CONDITION: Mode 1 or 2 or 3 Either of the following exists:

  • The reactor will remain subcritical without boron under all conditions, and

> Less than 4 MSRVs can be opened, or > Reactor pressure can NOT be restored and maintained above Suppression Chamber pressure by at least 70 psi.

  • It has NOT been determined that the reactor will remain subcritical without boron under all conditions and unable to restore and maintain MARFP in Table 1.1-G2.

OPERATING CONDITION: Mode 1 or 2 or 3 4 c: z c: (I) c: > r ~ m z -t r-m ~ (I) =i m m s: m

0 Ci) m z

0 -< Q m z m ~ r-m m ~ m z (")

liml Job Performance Measure (JPM) BFN ALERT EPIP-3 Rev 0036 UnitO Paae8 of23 APPENDIX A Page 1of1 ALERT INITIAL NOTIFICATION FORM

1.

i:gJ This is a Drill D This is an Actual Event - Repeat - This is an Actual Event

2. The SEO at Browns Ferry has declared an ALERT.
3. EAL Designator: ___

1_._1-_A_2 _____ (USE ONLY ONE EAL DESIGNATOR)

4. Radiological Conditions:

(Check one under both Airborne and Liquid column.) Airborne Releases Offsite ~ Minor releases within federally approved limits 1 D Releases above federally approved limits 1 D Release information not known ( 1Tech Specs/ODCM) Liquid Releases Offsite ~Minor releases within federally approved limits1 D Releases above federally approved limits 1 D Release information not known ( 1Tech Specs/ODCM)

5. Event Declared: Time: __

N_o_w ____ Date: __ T_o_d_a_.y.__ __ Central Time

6. Protective Action Recommendation:

(gl None Completed By : Student's signature Peer Checked By: 5

llml Job Performance Measure (JPM) START TIME: --- STEP/STANDARD Step 1: Refers to EPIP-1 to classify the event Standard: Classifies an ALERT, EAL 1.1-A2, based on uncontrolled water level decrease in Spent Fuel Storage Pool expected to result in irradiated fuel assemblies being uncovered. TIME CLASSIFIED: --- START TIME: __ STEP/STANDARD Step 2: Refers to EPIP-3 Standard: Completes Appendix A of EPIP-3, with the following critical items

  • Item 3 (EAL Designator)
  • Item 4 o Airborne Releases Offsite (Minor releases within federally approved limits) o Liquid Releases Offsite (Minor releases within federally approved limits)
  • Item 5 (Current time and date)
  • Signature TIME APPENDIX COMPLETE: ---

End of Task 6 SAT/UNSAT Critical Step SAT UNSAT N/A SAT/UNSAT Critical Step SAT _UNSAT N/A

IUEI Job Performance Measure (JPM) Provide to Applicant INITIAL CONDITIONS: You are the Shift Manager. Units 1, 2, and 3 were operating at 100% power when Unit 1 received Start of Strong Motion Accelerograph (9-22C, W5) and personnel in the Control Room felt the floor shake. The Condensate makeup valve 2-SHV-078-0532 is danger tagged closed. Unit 2 received Fuel Pool Skimmer Surge Tank Level Lo/Lo-Lo (9-4C, W4). Compensatory hoses connected to demin water connections are not maintaining Fuel Pool level. Unit 2 received Fuel Pool System Abnormal (9-4C, W1) AND Fuel Pool Floor Area Radiation High (9-3A, W1) The Fuel Pool liner is leaking and Fuel Pool level is lowering. Unit 2 entered 2-AOl-78-1, Fuel Pool Cleanup System Failure Loss of Offsite Power occurred and the C and D Diesel Generators failed to start. Unit 2 attempted to restore Fuel Pool level using EECW however, 1-SHV-067-0792 North Header supply to Emergency Fuel Pool Make Up will not open and the South EECW header is depressurized. Unit 2 attempted to align RHRSW to inject to the Fuel Pool; however, 1-FCV-23-57, Standby Coolant valve would not open electrically. The Fuel Pool leak is progressively getting larger and the Fuel Pool level will be at the top of the fuel bundles within 15 minutes. CURRENT CONDITIONS: Reactor Water Level (-) 20 inches and rising Reactor Pressure 650 psig and lowering OW Pressure 1.35 psig and steady OW Temperature 148 °F and steady SP Temperature 115 °F and slowly rising Torus Level +1 inch on narrow range and slowly rising Fuel Pool Level 15 feet below the ventilation duct opening 2-Rl-90-1A Fuel Pool Area El 664 250 mR/HR and slowly rising 2-Rl-90-2A Service Floor Area El 664 200 mR/HR and slowly rising Wind Direction 105° Wind Speed 10 mph O-Sl-4.8.b.1.a.1, Airborne Effluent Release Rate, Release Fraction 0.91 INITIATING CUE: Identify the HIGHEST REQUIRED emergency classification, and complete the required actions. Raise your hand immediately once you have classified the event, and the examiner will provide you with the EPIP associated with the classification you have declared. THIS JPM IS TIME CRITICAL 7}}