ML15078A386

From kanterella
Jump to navigation Jump to search

Transmittal of Draft Safety Evaluation Regarding License Amendment Request License Amendment Request for Technical Specification (TS) 3.1.3, Moderator Temperature Coefficient and TS 5.6.5, Core Operating Limits Report
ML15078A386
Person / Time
Site: Mcguire, Catawba, McGuire  
(NPF-009, NPF-017, NPF-035, NPF-052)
Issue date: 04/06/2015
From: Geoffrey Miller
Plant Licensing Branch II
To: Capps S, Henderson K
Duke Energy Carolinas
Miller G
References
TAC ME8829, TAC ME8830, TAC ME8831, TAC ME8832
Download: ML15078A386 (3)


Text

OFFICIAL USE ONLY PROPRIETARY INFORMATION UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Mr. K. Henderson Site Vice President Catawba Nuclear Station Duke Energy Carolinas, LLC 4800 Concord Road York, SC 29745 Mr. Steven D. Capps Vice President McGuire Nuclear Station Duke Energy Carolinas, LLC 12700 Hagers Ferry Road Huntersville, NC 28078 April 6, 2015

SUBJECT:

CATAWBA NUCLEAR STATION, UNITS 1AND2 AND MCGUIRE NUCLEAR STATION, UNITS 1AND2-TRANSMITTAL OF DRAFT SAFETY EVALUATION REGARDING LICENSE AMENDMENT REQUEST RE: LICENSE AMENDMENT REQUEST FOR TECHNICAL SPECIFICATION (TS) 3.1.3, "MODERATOR TEMPERATURE COEFFICIENT" AND TS 5.6.5, "CORE OPERATING LIMITS REPORT" (TAC NOS. ME8829, ME8830, ME8831, AND ME8832)

Dear Mr. Henderson and Mr. Capps:

By letter dated May 31, 2012 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML12153A328), Duke Energy Carolinas, LLC (Duke, the licensee),

submitted a license amendment request for Catawba Nuclear Station, Units 1 and 2, and McGuire Nuclear Station, Units 1 and 2. The proposed amendment requested review and approval of a conditional exception to the end-of-cycle Moderator Temperature Coefficient Surveillance Requirements. By letters dated March 13, 2013, and November 25, 2014 (ADAMS Accession No. ML13074A304 and ML14332A301, respectively), Duke provided a response to NRC staff RAls on the subject amendment request.

Enclosed is the draft Safety Evaluation (SE) that the Nuclear Regulatory Commission (NRC) staff has prepared to support the proposed license amendment. Pursuant to Section 2.390 of Title 10 of the Code of Federal Regulations (10 CFR), we have made a preliminary determination that the enclosed draft SE does not contain proprietary information, the NRC staff requests that the licensee confirm that the draft SE does not contain any information that is considered proprietary. If you believe that any information is proprietary, please identify such information line-by-line and define the basis pursuant to the criteria of 10 CFR 2.390. The NRC staff requests that Duke provide comments regarding the proprietary content in the draft SE OFFICIAL USE ONLY PROPRIETARY INFORMATION Enclosure transmitted herewith contains sensitive unclassified information When separated from enclosure, this transmittal document Is decontrolled

OFFICIAL USE ONLY PROPRIETARY INFORMATION K. Henderson and within 5 business days from the date of this letter. The response timeframe was discussed with Mr. Lawrence Rudy of your staff on April 6, 2015.

Since the NRC review is not yet complete, this letter and the enclosure do not convey or represent an NRC staff position regarding Duke's request. Should the amendment be approved, the NRC staff will issue a publicly-available, nonproprietary version of the SE.

If you have any questions regarding this matter, I may be reached at (301) 415-2481 or by e-mail at ed.miller@nrc.gov.

Sincerely,

/

"",,/

(__.. _J.7._;1..; / ('"~

G. Edward Miller, Project Manager Plant Licensing Branch 11-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-369, 50-370, 50-413, and 50-414

Enclosure:

Draft SE cc w/o encl: Distribution via Listserv OFFICIAL USE ONLY PROPRIETARY INFORMATION Enclosure transmitted herewith contains sensitive unclassified information When separated from enclosure, this transmittal document is decontrolled

ML15078A386 OFFICE NRR/DORL/LPL2-1 /PM NAME GE Miller DATE 4/6/15 RidsNrrLASFigueroa Resource RidsNrrPMMcGuire Resource RidsOgcMailCenter Resource RidsRgn2MailCenter Resource NRR/DORULPL2-1/LA NRR/DORL/LPL2-1/BC SFigueroa RPascarelli (VSreenivas for) 3/28/15 4/6/15