Entergy Entergy Nuclear Operations, Inc.
Pilgrim Nuclear Power Station 600 Rocky Hill Road Plymouth, MA 02360 John A Dent, Jr.
Site Vice President February 27, 2015 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001
SUBJECT:
Pilgrim Nuclear Power Station's Fourth Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051)
Pilgrim Nuclear Power Station Docket No. 50-293 License No. DPR-35 LETTER NUMBER 2.15.006
REFERENCE:
- 1. NRC Order Number EA-12-051, "Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation", dated March 12, 2012 (PNPS Letter 1.12.015) (ADAMS Accession No. ML12054A679)
- 2. NRC Interim Staff Guidance JLD-ISG-2012-03, Compliance with Order EA-12-051, Reliable Spent Fuel Pool Instrumentation, Revision 0, dated August 29, 2012 (ADAMS Accession No. ML12221A339)
- 3. Nuclear Energy Institute (NEI) 12-02, Revision 1, "Industry Guidance for Compliance with NRC Order EA-12-051, "To Modify Licenses with Regard to Reliable Spent Fuel Pool Instrumentation",
dated August 2012 (ADAMS Accession No. ML12240A307)
- 4. Pilgrim Nuclear Power Station Letter to NRC, "Initial Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051)", dated October 29, 2012 (PNPS Letter 2.12.074) (ADAMS Accession No, ML12312A469)
- 5. Pilgrim Nuclear Power Station Letter to NRC, "Overall Integrated Plan in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051)", dated February 28, 2013 (PNPS Letter 2.13.014) (ADAMS Accession No. ML13063A097)
Ab)
PNPS Letter 2.15.006 Page 2 of 4
Dear Sir or Madam:
On March 12, 2012, the Nuclear Regulatory Commission ("NRC" or "Commission")
issued an order (Reference 1) to Entergy. Reference 1 was immediately effective and directs Entergy to install reliable spent fuel pool level instrumentation. Specific requirements are outlined in Attachment 2 of Reference 1.
Reference 1 required submission of an initial status report 60 days following issuance of the final interim staff guidance (Reference 2) and an overall integrated plan pursuant to Section IV, Condition C. Reference 1 requires submission of a status report at six-month intervals following submittal of the overall integrated plan. Reference 3 provides direction regarding the content of the status reports. Reference 2 endorses industry guidance document NEI 12-02, Revision 1 (Reference 3) with clarifications and exceptions. Reference 4 provided the Pilgrim Station initial status report regarding spent fuel pool instrumentation. Reference 5 provided the Pilgrim Station Overall Integrated Plan.
The purpose of this letter is to provide the fourth six-month status report pursuant to Section IV, Condition C.2, of Reference 1, that delineates progress made in implementing the requirements of Reference 1. The attached report provides an update of milestone accomplishments since the last status report, including any changes to the compliance method, schedule, or need for relief and the basis, if any.
Should you have any questions concerning the content of this letter, please contact Mr.
Everett (Chip) Perkins Jr. at (508) 830-8323.
This letter contains no new regulatory commitments.
I declare under penalty of perjury that the foregoing is true and correct; executed on February 27, 2015.
Sincerely, John A. Dent Jr.
JAD/rmb
Attachment:
Pilgrim Nuclear Power Station's Fourth Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051)
PNPS Letter 2.15.006 Page 3 of 4 cc:
Mr. Daniel H. Dorman Regional Administrator, Region 1 U.S. Nuclear Regulatory Commission 2100 Renaissance Boulevard, Suite 100 King of Prussia, PA 19406-1415 NRC Resident Inspector Pilgrim Nuclear Power Station U. S. Nuclear Regulatory Commission Director, Office of Nuclear Reactor Regulation One White Flint North 11555 Rockville Pike Washington, DC 20555-0001 Ms. Nadiyah Morgan, Project Manager Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Mail Stop O-8C2A Washington, DC 20555 Mr. John Giarrusso Jr.
Planning, Preparedness & Nuclear Section Chief Mass. Emergency Management Agency 400 Worcester Road Framingham, MA 01702 U. S. Nuclear Regulatory Commission Attn: Robert J. Fretz Jr.
OWFN, Mailstop # 4A1 5A 11555 Rockville Pike Rockville, MD 20852-2378 U. S. Nuclear Regulatory Commission Attn: Robert L. Dennig OWFN, Mailstop # 10E1 11555 Rockville Pike Rockville, MD 20852-2378 U. S. Nuclear Regulatory Commission Attn: Ms. Lisa M. Regner OWFN, Mailstop # 11 F1 11555 Rockville Pike Rockville, MD 20852-2378 U. S. Nuclear Regulatory Commission Attn: Mr. Blake A. Purnell OWFN, Mailstop # 12D20 11555 Rockville Pike Rockville, MD 20852-2378
PNPS Letter 2.15.006 Page 4 of 4 U. S. Nuclear Regulatory Commission Attn: Mr. Steven R. Jones OWFN, Mailstop # 1OA1 11555 Rockville Pike Rockville, MD 20852-2378 U. S. Nuclear Regulatory Commission ATTN: Jessica A. Kratchman OWFN - Mailstop 9 D2 11555 Rockville Pike Rockville, MD 20852-2378
ATTACHMENT To PNPS Letter 2.15.006 PILGRIM NUCLEAR POWER STATION'S FOURTH SIX-MONTH STATUS REPORT IN RESPONSE TO MARCH 12, 2012 COMMISSION ORDER MODIFYING LICENSES WITH REGARD TO RELIABLE SPENT FUEL POOL INSTRUMENTATION (ORDER NUMBER EA-12-051)
PNPS's Fourth Six-Month Status Report for the Implementation of SFPI February 2015 Attachment Pilgrim Nuclear Power Station's Fourth Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051) 1 Introduction PNPS developed an Overall Integrated Plan (Reference 1), documenting the requirements to install reliable spent fuel pool level instrumentation (SFPI), in response to Reference 2. This attachment provides an update of milestone accomplishments since the last status report, including any changes to the compliance method, schedule, or need for relief/relaxation and the basis, if any.
2 Milestone Accomplishments The following milestone(s) have been completed since July 31, 2014 and are current as of January 31, 2015.
ISE RAIs dated December 5, 2013 (Reference 3) - Submitted 3
Milestone Schedule Status The following provides an update to milestone schedule to support the Overall Integrated Plan. This section provides the activity status of each item, and the expected completion date noting any change. The dates are planning dates subject to change as design and implementation details are developed.
Revised Target Milestone Target Completion Activity Status Completion Date Date Reliable SFPI Installed Spring 2015 Refueling In Progress N/A Outage NRC RAls dated June 20, July 19, 2013 Submitted N/A 2013 (Reference 5)
July 19, 2013 ISE RAls dated December 5, September 30, 2014 Submitted N/A 2013 (Reference 3)
September, 2014 4 Changes to Compliance Method There are no additional changes to the compliance method.
5 Need for Relief/Relaxation and Basis for the Relief/Relaxation PNPS expects to comply with the NRC Order implementation date and no relief/relaxation is required at this time.
Page 2 of 4
PNPS's Fourth Six-Month Status Report for the Implementation of SFPI February 2015 6
Open Items from Overall Integrated Plan and Interim Staff Evaluation PNPS has received an Interim Staff Evaluation that includes 16 RAIs. The following table provides a status of the RAIs.
RAI #
Response Status 1
Submitted in Reference 6 2
Uploaded to e-portal September 30, 2014 3
Uploaded to e-portal September 30, 2014 4
Uploaded to e-portal September 30, 2014 5
Uploaded to e-portal September 30, 2014 6
Uploaded to e-portal September 30, 2014 7
Uploaded to e-portal September 30, 2014 8
Uploaded to e-portal September 30, 2014 9
Uploaded to e-portal September 30, 2014 10 Submitted in Reference 6 11 Uploaded to e-portal September 30, 2014 12 Uploaded to e-portal September 30, 2014 13 Uploaded to e-portal September 30, 2014 14 Uploaded to e-portal September 30, 2014 15 Uploaded to e-portal September 30, 2014 16 Uploaded to e-portal September 30, 2014 7
Potential Interim Staff Evaluation Impacts There are no potential impacts to the Interim Staff Evaluation identified at this time.
Page 3 of 4
PNPS's Fourth Six-Month Status Report for the Implementation of SFPI February 2015 8 References The following references support the updates to the Overall Integrated Plan described in this attachment.
- 1. "PNPS's Overall Integrated Plan in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051)," dated February 28, 2013. (ADAMS Accession No. ML13063A097)
- 2. NRC Order Number EA-12-051, "Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation," dated March 12, 2012. (ADAMS Accession No. ML12054A679)
- 3. "Pilgrim Nuclear Power Station - Interim Staff Evaluation and Request for Additional Information Regarding the Overall Integrated Plan for Implementation of Order EA-12-051, "Issuance of Order to Modify Licenses with Regard to Reliable Spent Fuel Pool Instrumentation" (TAC NO. MF0778)," dated December 5, 2013. (ADAMS Accession No. ML13333A910)
- 4. "November 26, 2013, Public Meeting Summary for the Discussion Between the NRC Staff and Industry Concerning Responses to Staff Interim Evaluations for Spent Fuel Pool Instrumentation," dated December 26, 2013. (ADAMS Accession No. ML13347B030)
- 5. "Pilgrim Nuclear Power Station - Request for Additional Information RE: Overall Integrated Plan for Reliable Spent Fuel Pool Instrumentation (Order EA-12-051)(TAC NO. MF0778),"
dated June 20, 2013. (ADAMS Accession No. ML13165A276)
- 6. "Pilgrim Nuclear Power Station's Third Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051), dated August 28, 2014, (2.14.062) (ADAMS Accession No. ML14253A189)
Page 4 of 4