February 26, 2015 Dr. David E. Moncton, Director of the Nuclear Reactor Laboratory Massachusetts Institute of Technology 138 Albany Street Mail Stop NW 12-208 Cambridge, MA 02139
SUBJECT:
EXAMINATION REPORT NO. 50-020/OL-15-01, MASSACHUSETTS INSTITUTE OF TECHNOLOGY
Dear Dr. Moncton:
During the week of February 2, 2015, the U.S. Nuclear Regulatory Commission (NRC) administered an operator licensing examination at your Massachusetts Institute of Technology reactor. The examinations were conducted according to NUREG-1478, "Operator Licensing Examiner Standards for Research and Test Reactors," Revision 2. Examination questions and preliminary findings were discussed with those members of your staff identified in the enclosed report at the conclusion of the examination.
In accordance with Title 10 of the Code of Federal Regulations, Section 2.390, a copy of this letter and the enclosures will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records component of NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html. The NRC is forwarding the individual grades to you in a separate letter which will not be released publicly. Should you have any questions concerning this examination, please contact Mr. John T. Nguyen at (301) 415-4007 or via internet e-mail John.Nguyen@nrc.gov.
Sincerely,
/RA/
Kevin Hsueh, Chief Research and Test Reactors Oversight Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No.50-020
Enclosures:
- 1. Examination Report No. 50-020/OL-15-01
- 2. Facility Comments with NRC Resolution
- 3. Written Examination cc: w/o encl: See next page
Dr. David E. Moncton, Director February 26, 2015 of the Nuclear Reactor Laboratory Massachusetts Institute of Technology 138 Albany Street Mail Stop NW 12-208 Cambridge, MA 02139
SUBJECT:
EXAMINATION REPORT NO. 50-020/OL-15-01, MASSACHUSETTS INSTITUTE OF TECHNOLOGY
Dear Dr. Moncton:
During the week of February 2, 2015, the U.S. Nuclear Regulatory Commission (NRC) administered an operator licensing examination at your Massachusetts Institute of Technology reactor. The examinations were conducted according to NUREG-1478, "Operator Licensing Examiner Standards for Research and Test Reactors," Revision 2. Examination questions and preliminary findings were discussed with those members of your staff identified in the enclosed report at the conclusion of the examination.
In accordance with Title 10 of the Code of Federal Regulations, Section 2.390, a copy of this letter and the enclosures will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records component of NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html. The NRC is forwarding the individual grades to you in a separate letter which will not be released publicly. Should you have any questions concerning this examination, please contact Mr. John T. Nguyen at (301) 415-4007 or via internet e-mail John.Nguyen@nrc.gov.
Sincerely,
/RA/
Kevin Hsueh, Chief Research and Test Reactors Oversight Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No.50-020
Enclosures:
- 1. Examination Report No. 50-020/OL-15-01
- 2. Facility Comments with NRC Resolution
- 3. Written Examination cc: w/o encl: See next page DISTRIBUTION w/ encls.:
PUBLIC RidsNRRDPRPRTA RidsNRRDPRPRTB Facility File (CRevelle) O-07 F-08 ADAMS ACCESSION NO.: ML15043A745 OFFICE NRR/DPR/PROB NRR/DPR/PROB NRR/DPR/PROB NAME JNguyen CRevelle KHsueh DATE 02/18/2015 02/24/2015 02/26/2015 OFFICIAL RECORD COPY
Massachusetts Institute of Technology Docket No.50-020 cc:
City Manager City Hall Cambridge, MA 02139 Department of Environmental Protection One Winter Street Boston, MA 02108 Beverly Anderson, Interim Director Radiation Control Program Department of Public Health Schrafft Center, Suite 1M2A 529 Main Street Charlestown, MA 02129 John Giarrusso, Planning and Preparedness Division Chief Massachusetts Emergency Management Agency 400 Worcester Road Framingham, MA 01702-5399 Test, Research and Training Reactor Newsletter P.O. Box 118300 University of Florida Gainesville, FL 32611-8300
ENCLOSURE 1 U. S. NUCLEAR REGULATORY COMMISSION OPERATOR LICENSING INITIAL EXAMINATION REPORT REPORT NO.:
50-020/OL-15-01 FACILITY DOCKET NO.:
50-020 FACILITY LICENSE NO.:
R-37 FACILITY:
MITR-II EXAMINATION DATES:
February 3 -4, 2015 SUBMITTED BY:
John T. Nguyen, Chief Examiner Date
SUMMARY
During the week of February 2, 2015, the NRC administered operator licensing examinations to one Senior Reactor Operator-Instant, one Senior Reactor Operator-Upgrade, and one Reactor Operator-Retake candidates. The Reactor Operator-Retake candidate failed the Section A, Reactor Theory, Thermo-hydraulics and Facility Operating Characteristics, of the written examination. The other two candidates passed all applicable portions of the examinations.
REPORT DETAILS
- 1.
Examiners:
John T. Nguyen, Chief Examiner, NRC Michele C. DeSouza, Examiner Trainee, NRC
- 2.
Results:
RO PASS/FAIL SRO PASS/FAIL TOTAL PASS/FAIL Written 0/1 1/0 1/1 Operating Tests 0/0 2/0 2/0 Overall 0/1 2/0 2/1
- 3.
Exit Meeting:
Kevin Hsueh, Chief, RTR, NRC John T. Nguyen, Chief Examiner, NRC Michele C. DeSouza, Examiner Trainee, NRC Frank Warmsley, Asst. Superintendent and Training Supervisor, MIT Edward Lau, Assistant Director of Operations, MIT Susan Tucker, Quality Assurance Supervisor, MIT Upon completion of the examinations, the NRC Examiners met with facility staff representatives to discuss the results. The facility licensee had various comments on the written examination that were incorporated in the examination report (see enclosure 2). At the conclusion of the meeting, the NRC examiners thanked the facility for their support in the administration of the examinations.
ENCLOSURE 2 FACILITY COMMENTS ON THE WRITTEN EXAM WITH NRC RESOLUTION QUESTION A.06
[1.0 point]
Which ONE of the following correctly describes the SIX-FACTOR FORMULA?
- a.
K = Keff
- the utilization factor
- b.
Keff = K
- the total leakage probability
- c.
K = Keff
- the total leakage probability
- d.
Keff = K
- the total non-leakage probability Answer:
- d.
REF:
Burn, R., Introduction of Nuclear Reactor Operations, © 1988, Sec 3.3 Facility Comments:
The answer key has D as the correct answer, and it is.
However when one of the candidates was receiving training on this very item, the notes that he was given by the instructor contained an error. This error was found and corrected after the training was completed for this candidate. However the correction was never passed along to the candidate. After the exam was taken, it was discovered that he was never informed of the correction in his notes and hence his knowledge.
Facility Recommendation: We ask if any consideration can be given for this particular candidate only in such that if the material that was later corrected, was in fact passed along to the candidate, we believe he would have correctly answered the question. This is evidenced by the other candidate who did take the later course with the corrected information choosing the correct answer.
Reference:
None NRC Resolution: The NRC does NOT accept the comment and accepts only d. as the correct answer.
QUESTION A.17
[1.0 point]
Which ONE of the following has the largest neutron capture cross section?
- a.
B-10
- b.
Sm-149
- c.
Xe-135
- d.
Answer: c
Reference:
Burn, R., Introduction to Nuclear Reactor Operations, © 1988, Sec 8.1 Facility Comments: The answer key has C. as the correct answer, however, both candidates answered A. They answered A because they know that the reactor uses Boron as the neutron absorbing substance in the shim blades and that in power reactors that insert a poison in the water, it is also boron used. Without a chart that shows the relative neutron absorption cross sections for the isotopes given, they chose the answer that they knew.
Facility Recommendation: We request that answer A be accepted as a correct answer for this test. If the question is used in future tests, that a chart be provided that can be used for identifying the cross sections for the various isotopes.
Reference:
None NRC Resolution: This is a standard NRC question and the NRC accepts only c as the correct answer.
ENCLOSURE 3 U. S. NUCLEAR REGULATORY COMMISSION NON-POWER REACTOR LICENSE EXAMINATION FACILITY:
Massachusetts Institute of Technology REACTOR TYPE:
MITR II Research DATE ADMINISTERED:
2/4/2015 CANDIDATE:
INSTRUCTIONS TO CANDIDATE:
Answers are to be written on the Answer sheet provided. Attach all Answer sheets to the examination. Point values are indicated in parentheses for each question. A 70% in each category is required to pass the examination. Examinations will be picked up three (3) hours after the examination starts.
% OF CATEGORY % OF CANDIDATE'S CATEGORY VALUE TOTAL SCORE VALUE CATEGORY 20.00 33.3 A. REACTOR THEORY, THERMODYNAMICS AND FACILITY OPERATING CHARACTERISTICS 20.00 33.3 B. NORMAL AND EMERGENCY OPERATING PROCEDURES AND RADIOLOGICAL CONTROLS 20.00 33.3 C. FACILITY AND RADIATION MONITORING SYSTEMS 60.00 % TOTALS FINAL GRADE All work done on this examination is my own. I have neither given nor received aid.
Candidate's Signature
A. RX THEORY, THERMO & FAC OP CHARS A N S W E R S H E E T Multiple Choice (Circle or X your choice)
If you change your Answer, write your selection in the blank.
A01 a b c d ___
A02 a b c d ___
A03 a b c d ___
A04 a b c d ___
A05 a b c d ___
A06 a b c d ___
A07 a b c d ___
A08 a b c d ___
A09 a b c d ___
A10 a b c d ___
A11 a b c d ___
A12 a b c d ___
A13 a b c d ___
A14 a b c d ___
A15 a b c d ___
A16 a b c d ___
A17 a b c d ___
A18 a b c d ___
A19 a b c d ___
A20 a b c d ___
(***** END OF CATEGORY A *****)
B. NORMAL/EMERG PROCEDURES & RAD CON A N S W E R S H E E T Multiple Choice (Circle or X your choice)
If you change your Answer, write your selection in the blank.
B01 a b c d ___
B02 a ___ b ___ c ___ d ___ (0.25 each)
B03 a ___ b ___ c ___ d ___ (0.25 each)
B04 a b c d ___
B05 a b c d ___
B06 a b c d ___
B07 a b c d ___
B08 a b c d ___
B09 a b c d ___
B10 a b c d ___
B11 a b c d ___
B12 a b c d ___
B13 a b c d ___
B14 a b c d ___
B15 a b c d ___
B16 a b c d ___
B17 a b c d ___
B18 a b c d ___
B19 a b c d ___
B20 a b c d ___
(***** END OF CATEGORY B *****)
C. PLANT AND RAD MONITORING SYSTEMS A N S W E R S H E E T Multiple Choice (Circle or X your choice)
If you change your Answer, write your selection in the blank.
C01 a b c d ___
C02 a b c d ___
C03 a b c d ___
C04 a ___ b ___ c ___ d ___ (0.25 each)
C05 a b c d ___
C06 a b c d ___
C07 a b c d ___
C08 a b c d ___
C09 a b c d ___
C10 a ___ b ___ c ___ d ___ (0.25 each) e ___ f ___ g ___ h ___
C11 a b c d ___
C12 a b c d ___
C13 a b c d ___
C14 a b c d ___
C15 a b c d ___
C16 a b c d ___
C17 a b c d ___
C18 a b c d ___
C19 a b c d ___
(***** END OF CATEGORY C *****)
(********** END OF EXAMINATION **********)
NRC RULES AND GUIDELINES FOR LICENSE EXAMINATIONS During the administration of this examination the following rules apply:
- 1.
Cheating on the examination means an automatic denial of your application and could result in more severe penalties.
- 2.
After the examination has been completed, you must sign the statement on the cover sheet indicating that the work is your own and you have neither received nor given assistance in completing the examination. This must be done after you complete the examination.
- 3.
Restroom trips are to be limited and only one candidate at a time may leave. You must avoid all contacts with anyone outside the examination room to avoid even the appearance or possibility of cheating.
- 4.
Use black ink or dark pencil only to facilitate legible reproductions.
- 5.
Print your name in the blank provided in the upper right-hand corner of the examination cover sheet and each Answer sheet.
- 6.
Mark your Answers on the Answer sheet provided. USE ONLY THE PAPER PROVIDED AND DO NOT WRITE ON THE BACK SIDE OF THE PAGE.
- 7.
The point value for each question is indicated in [brackets] after the question.
- 8.
If the intent of a question is unclear, ask questions of the examiner only.
- 9.
When turning in your examination, assemble the completed examination with examination questions, examination aids and Answer sheets. In addition turn in all scrap paper.
- 10.
Ensure all information you wish to have evaluated as part of your Answer is on your Answer sheet. Scrap paper will be disposed of immediately following the examination.
- 11.
To pass the examination you must achieve a grade of 70 percent or greater in each category.
- 12.
There is a time limit of three (3) hours for completion of the examination.
EQUATION SHEET eff = 0.1/sec T
=
H m
=
T c
m
=
Q p
(k) 2
)
(
=
P 2
max seconds 10 x 1
=
-4 sec
-1 eff 0.1
=
)
K (1
CR
=
)
K (1
CR eff 2
eff 1
2 1
K 1
S
=
SCR eff
26.06
=
SUR eff K
1 K
1
=
M eff eff 1
0 CR CR
=
K 1
1
=
M 2
1 eff 10 P
=
P SUR(t) 0 e
P
=
P t
0 P
)
(1
=
P 0
=
eff
+
=
K
)
K (1
=
SDM eff eff K
x k
K K
=
eff eff eff eff 2
1 1
2
0.693
=
T K
1)
K
(
=
eff eff
e DR
=
DR t
0 R
6CiE(n)
=
DR 2
d DR
=
d DR 2
2 2
1 2
1
1 Curie = 3.7x1010 dps 1 kg = 2.21 lbm 1 hp = 2.54x103 BTU/hr 1 Mw = 3.41x106 BTU/hr 1 BTU = 778 ft-lbf EF = 9/5EC + 32 931 Mev = 1 amu EC = 5/9 (EF - 32)
Section A L Theory, Thermo & Fac. Operating Characteristics QUESTION A.01
[1.0 point]
Elastic Scattering is the process whereby a neutron collides with a nucleus and:
- a.
recoils with the same kinetic energy it had prior to the collision.
- b.
recoils with the lower kinetic energy, with the nucleus emitting a gamma ray.
- c.
is absorbed by the nucleus, with the nucleus emitting a gamma ray.
- d.
recoils with the higher kinetic energy, with the nucleus emitting a beta particle.
QUESTION A.02
[1.0 point]
Reactor is increasing power from 10 W to 1 MW when the reactor operator accidently inserted a sample worth of 1.0 % K/K into the reactor core. Which ONE of the following best describes the values of Keff and during the power increment?
- a.
Keff = 1 and 0 < < 1
- b.
Keff > 1 and 0 < < -eff
- c.
Keff > 1 and -eff < < 1
- d.
Keff > 1 and 1 < < infinity ()
QUESTION A.03
[1.0 point]
Few minutes following a reactor scram, the reactor period has stabilized and the power level is decreasing at a CONSTANT rate. What is the reactor power one minute later from 50 kW?
- a.
106 kW
- b.
5 kW
- c.
24 kW
- d.
38 kW
Section A L Theory, Thermo & Fac. Operating Characteristics QUESTION A.04
[1.0 point]
Which ONE of the following elements will slow down fast neutron LEAST quickly, produces the smallest energy loss per collision?
- a.
Hydrogen-1
- b.
Boron-10
- c.
Oxygen-16
- d.
Uranium-238 QUESTION A.05
[1.0 point]
Reactor A with a Keff of 0.1 and reactor B with a Keff of 0.6, Keff is increased by 0.1 for each reactor. The amount of reactivity added in reactor A is ______ in reactor B for the same increment.
- a.
less than
- b.
same
- c.
six times
- d.
twenty-one times QUESTION A.06
[1.0 point]
Which ONE of the following correctly describes the SIX-FACTOR FORMULA?
- a.
K = Keff
- the utilization factor
- b.
Keff = K
- the total leakage probability
- c.
K = Keff
- the total leakage probability
- d.
Keff = K
- the total non-leakage probability
Section A L Theory, Thermo & Fac. Operating Characteristics QUESTION A.07
[1.0 point]
Which ONE of the following describes the term PROMPT JUMP?
- a.
A reactor is increasing power at a constant rate of +80 second period
- b.
The instantaneous change in power level due to inserting control rods
- c.
The instantaneous change in power level due to inserting negative worth, - 0.3 %k/k, of experiment
- d.
The instantaneous change in power level due to removing negative worth,- 0.3 %k/k, of experiment QUESTION A.08
[1.0 point]
Given the associated graph, which of the following answers best describe the neutron behavior within Region III?
- a.
The neutron cross section is inversely proportional to the neutron velocity (1/V)
- b.
The neutron cross section decreases steadily with increasing neutron energy (1/E)
- c.
Neutrons in this region have more likely to be fissionable than neutrons in region II
- d.
Neutrons in this region are more likely to be absorbed than neutrons in region I
Section A L Theory, Thermo & Fac. Operating Characteristics
Section A L Theory, Thermo & Fac. Operating Characteristics QUESTION A.09
[1.0 point]
Which ONE of the following is a number of neutrons in the Uranium-235 nucleus (92U235 )?
- a.
92
- b.
143
- c.
235
- d.
The U-235 doesnt have a constant number of neutrons, it fluctuates between 95 and 140.
QUESTION A.10
[1.0 point]
A reactor is slightly supercritical with the following values for each of the factors in the six-factor formula:
Fast fission factor 1.03 Fast non-leakage probability 0.84 Resonance escape probability 0.96 Thermal non-leakage probability 0.88 Thermal utilization factor 0.70 Reproduction factor 1.96 A control rod is inserted to bring the reactor back to critical. Assuming all other factors remain unchanged, the new value for the thermal utilization factor is:
- a.
0.698
- b.
0.702
- c.
0.074
- d.
0.076 QUESTION A.11 [1.0 point]
The reactor is on a CONSTANT positive period. Which ONE of the following power changes will take the longest time to complete?
- a.
5%, from 95% to 100%
- b.
10%, from 80% to 90%
- c.
15%, from 15% to 30%
- d.
20%, from 60% to 80%
Section A L Theory, Thermo & Fac. Operating Characteristics QUESTION A.12
[1.0 point]
Delayed neutrons are produced by:
- a.
decay of gamma
- b.
Photoelectric Effect
- c.
decay of fission fragments
- d.
directly from the fission process QUESTION A.13
[1.0 point]
Which ONE of the following is the MAIN reason for operating reactor with thermal neutrons instead of fast neutrons?
- a.
The fission cross section of the fuel is much higher for fast neutrons than thermal energy neutrons. Since fast neutrons are easier to cause fission, a reactor cannot control with fast neutrons.
- b.
The neutron lifetime of thermal neutrons is longer than fast neutrons, so the fuel has enough time to capture thermal neutrons.
- c.
The fission cross section of the fuel is much higher for thermal energy neutrons than fast neutrons, so thermal neutrons are easier to cause fission.
- d.
The atomic weight of thermal neutrons is larger than fast neutrons, so thermal neutrons are easily to slow down and be captured by the fuel.
QUESTION A.14
[1.0 point]
A reactor is subcritical with Keff of 0.955. Which ONE of the following is the MINIMUM reactivity (DK/K) that must be added to produce a PROMPT criticality? Given eff=0.0078
- a.
0.0450
- b.
0.0078
- c.
0.0548
- d.
0.1000
Section A L Theory, Thermo & Fac. Operating Characteristics QUESTION A.15
[1.0 point]
Following a positive reactivity addition to a shutdown reactor, the neutron power will increase even though k-effective is less than 1. The MAIN reason is due to:
- a.
Subcritical multiplication process
- b.
Neutron moderation in the fuel
- c.
Production of fast neutrons
- d.
Void temperature coefficient in the moderator QUESTION A.16
[1.0 point]
The RESONANCE ESCAPE PROBABILITY is defined as a ratio of:
- a.
the number of thermal neutrons absorbed in fuel over the number of thermal neutrons absorbed in fuel and core materials.
- b.
the number of fast neutrons produced by fission in a generation over the number of total neutrons produced by fission in the previous generation.
- c.
the number of fast neutrons produced by U-238 over the number of thermal neutrons absorbed in fuel.
- d.
the number of neutrons that reach thermal energy over the number of fast neutrons that start to slow down.
QUESTION A.17
[1.0 point]
Which ONE of the following has the largest neutron capture cross section?
- a.
B-10
- b.
Sm-149
- c.
Xe-135
- d.
Section A L Theory, Thermo & Fac. Operating Characteristics QUESTION A.18
[1.0 point]
Reactor is at 100 % power. The following graph shows the reactor time behavior following a reactor scram. Which ONE of the following best describes the transition of power between point C and D after the initial insertion?.
- a.
An immediate decrease in the prompt neutron fraction due to leakage, absorption, and a reduction in the fission rate
- b.
Fission product gases such as xenon begin to buildup causing the expansion of fuel density
- c.
The longest lived delayed neutron precursor begins to effect
- d.
The short lived delayed neutron precursors begin to effect
Section A L Theory, Thermo & Fac. Operating Characteristics
Section A L Theory, Thermo & Fac. Operating Characteristics QUESTION A.19 [1.0 point]
Which ONE of the following best describes the alpha decay of a nuclide?
- a.
The atomic mass number increases by 2, and the number of protons increase by 1
- b.
The atomic mass number decreases by 2, and the number of protons decrease by 2
- c.
The atomic mass number decreases by 4, and the number of protons decrease by 2
- d.
The atomic mass number increases by 4, and the number of protons increase by 2 QUESTION A.20
[1.0 point]
As primary coolant temperature increases, a control blade worth:
- a.
increases due to the increase in thermal diffusion length
- b.
decreases due to higher neutron adsorption in the moderator
- c.
decreases due to a water density in the primary tank increases
- d.
remains the same due to same amount of poison in the control blade
(***** END OF CATEGORY A *****)
Section B Facility and Radiation Monitoring Systems QUESTION B.01
[1.0 point]
Per MITR Technical Specifications, which ONE of the following statements is NOT true for reactor operations?
- a.
Reactor Operator at the console has the authority and duty to shutdown the reactor at any time if he feels it necessary.
- b.
Whenever the reactor is NOT secured, two persons shall be onsite, one of whom shall be a licensed senior reactor operator.
- c.
The Radiation Protection Officer shall be onsite at all time when the reactor is NOT shutdown.
- d.
The shift supervisor shall be present in the control room during the startups and increase in power of greater than 10%.
QUESTION B.02
[1.0 points, 0.25 each]
Match the following 10CFR parts:
Column A Column B
- a.
Operators Licenses
- 1. Part 19
- b.
Standards for Protection against Radiation
- 2. Part 20
- c.
Notices, Instructions, and Reports to Workers
- 3. Part 50
- d.
Domestic Licensing of Production and Utilization Facilities
- 4. Part 55 QUESTION B.03
[1.0 point, 0.25 each]
Match the Plans and Procedures listed in Column A with its corresponding Classifications listed in column B. Answer in Column B can be used once, more than once, or not at all.
Column A Column B
- a.
- 1. Class A
- b.
Abnormal Operating Procedure
- 2. Class B
- c.
Technical Specification Tests
- 3. Class C
- d.
Scram Tests
Section B Facility and Radiation Monitoring Systems QUESTION B.04
[1.0 point]
During continuous power operation with the automatic control system, it may be necessary for the operator to reshim the control blades to maintain the regulating rod within its useful range.
Which ONE of the following describes the requirements associated with this reshim of control blades?
- a.
The duty supervisor must approve all reshims prior to performance.
- b.
Reactor power is to be maintained within 2.5% of the desired level while reshimming.
- c.
All shim blades must be maintained within 2.5 inches of each other during the reshim and within 1.0 inch following the reshim.
- d.
The first motion of any control absorber during a reshim should be inward so as to lower reactor power.
QUESTION B.05
[1.0 point]
Per MITR Technical Specification, Shim blade and Regulating rod drive shall be inspected
________ for proper operation.
- a.
Monthly
- b.
Quarterly
- c.
Semi-annually
- d.
Annually QUESTION B.06
[1.0 point]
Assume an individual has received whole body occupational exposures of:
10 mrads of beta 10 mrads of alpha 10 mrads of gamma What would be the cumulative dose equivalent (HT) in mrem for this individual?
- a.
30 mrem
- b.
220 mrem
- c.
260 mrem
- d.
310 mrem
Section B Facility and Radiation Monitoring Systems QUESTION B.07
[1.0 point]
Per MITR Technical Specifications, which ONE of the following will violate the Limiting Safety System Settings with ONE pump operation?
- a.
Primary Coolant Flow = 1800 gpm
- b.
Core Outlet Water Temperature = 65 °C
- c.
Steady State Power = 3.0 MW
- d.
Coolant height of 11 feet above top of fuel plates QUESTION B.08
[1.0 point]
A biennial test of the nuclear instrument was performed. Per MITR Technical Specifications, which ONE of the following is the latest the test that must be performed again without overdue?
- a.
7.5 months after
- b.
26 months after
- c.
29 months after
- d.
31 months after QUESTION B.09
[1.0 point]
Per MITR Technical Specifications, the MINIMUM number of radiation area monitors required during reactor operations is:
- a.
One
- b.
Two
- c.
Three
- d.
No requirement
Section B Facility and Radiation Monitoring Systems QUESTION B.10
[1.0 point]
What class of emergency would be declared, If 100 mrem/hour for 1-hour whole body or 500 mrem thyroid dose at the site boundary?
- a.
Unusual Event
- b.
Alert
- c.
Site Area
- d.
General QUESTION B.11
[1.0 point]
The individual authorized to terminate or downgrade the emergency and to initiate recovery operation is the:
- a.
Emergency Coordinator
- b.
Radiation Protection Officer
- c.
MIT Campus Police Chief
- d.
Emergency Director QUESTION B.12
[1.0 point]
A one-curie source, emitted 100% of 1 Mev gamma, is to be stored in the reactor building. How far from the source should a HIGH RADIATION AREA sign be posted?
- a.
5 feet
- b.
8 feet
- c.
11 feet
- d.
16 feet
Section B Facility and Radiation Monitoring Systems QUESTION B.13
[1.0 point]
A 20-ml sample of primary water is brought to the spectrum analyzer for nuclide identification.
What is the dominant nuclide you would expect in that sample, assuming it is a routine (normal) operation (no fuel leak)?
- a.
Na-24
- b.
- c.
Xe-135
- d.
I-131 QUESTION B.14
[1.0 point]
Which ONE of the following is the definition of Total Effective Dose Equivalent (TEDE) specified in 10 CFR Part 20?
- a.
The sum of thyroid dose and external dose
- b.
The sum of the external deep dose and the organ dose
- c.
The sum of the deep dose equivalent and the committed effective dose equivalent
- d.
The dose that your whole body is received from the source, but excluded from the deep dose QUESTION B.15
[1.0 point]
The MAIN purpose of limit deuterium concentration in the helium blanket is to prevent:
- a.
pressure build up in the helium blanket
- b.
flammability of deuterium in the helium blanket
- c.
high level of deuterium hazards in the reactor bay
- d.
fuel cladding damage due to deuterium interacting with aluminum
Section B Facility and Radiation Monitoring Systems QUESTION B.16
[1.0 point]
Select the list that gives the order of types of radiation from the LEAST penetrating to the MOST penetrating (i.e. travels the further in air).
- a.
neutron, gamma, beta, alpha
- b.
alpha, beta, neutron, gamma
- c.
beta, alpha, gamma, neutron
- d.
alpha, neutron, beta, gamma QUESTION B.17
[1.0 point]
The MITR shall notify the U.S. NRC within 30 days when the licensed operator or senior operator terminates his or her license. This requirement can be found in:
- a.
10 CFR Part 19
- b.
10 CFR Part 20
- c.
10 CFR Part 50
- d.
10 CFR Part 55 QUESTION B.18
[1.0 point]
Which ONE of the following statements describes the requirement that must be observed when "locking out" facility equipment after permission is granted?
- a.
SRO witness lockout; SRO will verify safe system condition; Superintendent must be notified; the system must be tagged out and a notation as to the system being locked out shall be made on the status board.
- b.
RO will witness lockout; RO will verify safe system condition; SRO must be notified; the system must be tagged out and a notation as to the system being locked out shall be made on the status board.
- c.
SRO will witness lockout; person performing the work will perform lockout; person performing the work will retain the key on their person; the system must be tagged out and a notation as to the system being locked out shall be made on the status board.
- d.
SRO will verify safe system condition; any member of the Radiation Protection Office Staff will witness lockout; person performing the work will perform lockout; the person performing the work will retain the key on their person and the system must be tagged out.
Section B Facility and Radiation Monitoring Systems QUESTION B.19
[1.0 point]
Corrosive materials that could affect or react with another material present in the reactor system shall be:
- a.
limited to 1 millicurie
- b.
limited to 1 milligram
- c.
limited to 1 milliliter
- d.
doubly encapsulated QUESTION B.20
[1.0 point]
How long will it take a 50 curie source, with a half-life of 5.27 years, to decay to 2 Curie?
- a.
10 Years
- b.
15 Years
- c.
25 Years
- d.
35 Years
(***** END OF CATEGORY B *****)
Section C Facility and Radiation Monitoring Systems QUESTION C.01
[1.0 point]
Auto control system will prevent reactor switching to auto control mode when:
- a.
The regulating rod is at 2-in position
- b.
Period channel exceeds 60 second period
- c.
One of the SHIM blades is at 8-in position
- d.
The deviation between the power-set and the actual power exceeds 1.5%
QUESTION C.02
[1.0 point]
Which ONE of the following is the correct operation for the reactor MAIN exhaust damper of the ventilation system?
- a.
Air to open/spring to close/butterfly valves
- b.
Spring to open/Air to close/ ball valves
- c.
hydraulic to open/spring to close/ ball valves
- d.
hydraulic to open/hydraulic to close/ butterfly valves QUESTION C.03
[1.0 point]
The MAIN function of the fixed, absorber plates on the absorber spider assembly is to
- a.
MINIMIZE neutron flux in the lower half of the core and MAXIMIZE power peaking at the top of the core.
- b.
MINIMIZE the fuel burn-up in the lower half of the core and MINIMIZE Nitrogen-16 peaking at the top of the core.
- c.
MAXIMIZE neutron flux in the lower half of the core and MINIMIZE power peaking at the top of the core.
- d.
MINIMIZE the fuel burn-up in the lower half of the core and MAXIMIZE power peaking at the top of the core.
Section C Facility and Radiation Monitoring Systems QUESTION C.04
[1.0 point, 0.25 each]
Reactor is at full power. Match the input signals listed in column A with their AUTOMATIC responses listed in column B. (Items in column B can be used once, more than once or not at all.)
Column A Column B
- a.
Intake damper oil pressure = 680 psig
- 1.
Normal
- b.
Reg rod reaches near-in limit position and no operator action for 30 sec
- 2.
Interlock
- c.
Voltage Chamber power supply = 0 V
- 3.
Rod Run down
- d.
Temperature Reactor Outlet = 40 °C
- 4.
Scram QUESTION C.05
[1.0 point]
Which ONE of the following is the correct reason for the Main Personnel Airlock Gaskets Deflated alarm and reactor scram?
- a.
The Utility Room (UR) air compressor supplied air to door gaskets exceeds 40 psig.
- b.
Both the UR and the Nuclear Engineering Building (NEB) air compressors are inoperable. No air is supplied to door gaskets.
- c.
The UR air compressor is NOT operable, only the Nuclear Engineering Building air compressor is supplied air to door gaskets.
- d.
A check valve fails; causing the UR air compressor stops supplying air to door gaskets; but directly vented air to the NEB air compressor.
Section C Facility and Radiation Monitoring Systems QUESTION C.06
[1.0 point]
Which ONE of the following reasons could cause a High Temperature HE-1 Primary Outlet alarm?
- a.
A temperature detector located at the outlet of the main primary heat exchanged exceeds its setpoint.
- b.
A temperature detector located at the inlet of the main primary heat exchanged exceeds its setpoint.
- c.
Shutdown the auxiliary pump MM-2, so no surge volume is available to compensate for volume changes due to heatup and cooldown.
- d.
A temperature detector located at the outlet of the cooling tower is disconnected.
QUESTION C.07
[1.0 point]
Which ONE of following actions should the reactor operator perform immediately when the rabbit station radiation monitor alarms during rabbit irradiation (AUTO Transfer 1PH1 >
NW13)?
- a.
Commence an unscheduled Shutdown and dump the reflector
- b.
Eject the sample into hot cell using the Abort Auto Transfer pushbutton
- c.
Eject the sample into hot cell using the OPERATE RESET pushbutton
- d.
Immediately shutdown the reactor. When radiation levels are less than the permissible limit, push the 1PH1 Eject pushbutton to remove the sample.
QUESTION C.8
[1.0 point]
The primary concern associated with the pressure relief system when charcoal filters becoming submersed during a large leak of primary coolant is:
- a.
loss of efficiency in moving particulates.
- b.
possible spontaneous combustion during dryout.
- c.
reduction in relief flow capability to relieve pressure.
- d.
possible spread of contaminants previously trapped in the charcoal.
Section C Facility and Radiation Monitoring Systems QUESTION C.9
[1.0 point]
In the event of a loss of building power, the emergency battery will DIRECTLY provide
- a.
120V-AC power to the Emergency Lightning Panel
- b.
120V-DC power to the Emergency Lightning Panel
- c.
120V-DC power to the reactor control room light and medical facility room light
- d.
There are no systems directly received a 120V-DC power from the emergency battery QUESTION C.10
[2.0 points, 0.25 each]
Match each monitor and instrument (channel) listed in column A with a specific purpose in column B. Items in column B is to be used only once.
Column A Column B
- a.
Channel 3.
- 1.
Monitor radiation level in the reactor top.
- b.
Channel 4.
- 2.
Detect radioisotopes released due to fuel failure.
- c.
High Level Emergency Power Channel
- 3.
Determine the effluent of Ar-41.
(HLEPC)
- d.
Portable monitor.
- 4.
Survey of laboratory.
e Log Count-Rate channel.
- 5.
Monitor neutron level during the reactor startup.
- f.
Area radiation monitor.
- 6.
Provide a period scram.
- g.
Stack Gas monitor.
- 7.
Provide a high power level scram.
- h.
Plenum Particulate monitor. 8.
Provide indication of the reactor power level when all off-site electrical power has been lost.
Section C Facility and Radiation Monitoring Systems QUESTION C.11
[1.0 point]
When the core tank and the reflector tank simultaneously ruptured, which ONE of the following is the proper procedure to add the city water to the reactor core?
- a.
Manually connect the quick-connect hoses to a pair of valves (MV-67 and 68), then open MV-69 and MV-70.
- b.
Turn the MM-1 ON, open the reflector valve (DV-1), and thus providing city water to the core with pressure.
- c.
Low pool water level automatically opens check valves, thus providing city water to the core.
- d.
There is no way for city water to be sent directly to the reactor core; the only source is the makeup water tank.
QUESTION C.12
[1.0 point]
When the off-gas system is isolated and H2 concentration exceeds 1% in the air space above the primary water pool system, the MAXIMUM reactor power level shall be less than:
- a.
1000 kW
- b.
300 kW
- c.
200 kW
- d.
100kW QUESTION C.13
[1.0 point]
Which ONE of the following is the correct formula for calculating the thermal power hourly on the reactor operating data log?
- a.
Primary power + Reflector power + Shield power
- b.
Primary power - Secondary power + Reflector power + Shield power
- c.
Primary power + Secondary power + Reflector power + Shield power
- d.
(Primary power + Secondary power)/2 + Reflector power + Shield power
Section C Facility and Radiation Monitoring Systems QUESTION C.14
[1.0 point]
Which ONE of the following is considered a NORMAL range of the pH primary coolant?
- a.
6.0 - 7.0
- b.
7.0 - 8.0
- c.
8.0 - 9.0
- d.
9.0 - 10.0 QUESTION C.15
[1.0 point]
All free surfaces of the D2O in the reflector system are blanketed with helium. Which ONE of the following is NOT the intent of this system? The intent of this system is NOT to:
- a.
Provide an inert, non-radioactive vehicle to circulate the disassociated D2 and O2 from the reflector tank to the re-combiner.
- b.
Prevent the corrosion that would be caused by nitrous-oxide formation from air in the presence of high radiation fields.
- c.
Prevent air with entrained H2O moisture from entering the system, coming in contact with the D2O, and degrading it.
- d.
Prevent O2 in air coming in contact with N16, and could cause flammability.
QUESTION C.16
[1.0 point]
The primary function of the discriminator in the Channel 1 is to:
- a.
amplify pulses produced by alpha particles resulting from the natural decay of fission fragment.
- b.
distinguish the pulses created by neutron-induced fissions from pulses produced by the gamma rays for the true signal.
- c.
convert pulses created by neutron-induced fissions into a d.c. current
- d.
filter out ALL pulses created by neutron-induced fissions and select ONLY pulses produced by the gamma rays for the true signal.
Section C Facility and Radiation Monitoring Systems QUESTION C.17
[1.0 point]
The following figure depicts:
- a.
MITR Limiting Safety System Settings for forced convection operation with two pumps
- b.
MITR Limiting Safety System Settings for forced convection operation with one pump
- c.
MITR Limiting Safety System Settings for natural convection operation with no pump
- d.
MITR Safety Limit for forced convection operation 4
5 6
7 8
9 50 55 60 65 70 75 80 Reactor Outlet Temperature, Tout (°C)
Coolant Height, H =10 feet Primary Flow Rate, Wp=1800 gpm Ffdf = 0.8 FH = 1.173 FT = 1.275 FcoreFr = 2.0
Section C Facility and Radiation Monitoring Systems QUESTION C.18
[1.0 point]
Figure 8-1 depicts the MIT normal and emergency electrical distribution. In the event of a loss of off-site power, which ONE of the following will distribute power to the Panel 2A?
- a.
Panel 2 Circuits
- b.
5-kW generator
- c.
Main power distribution
- d.
There are no systems that provide power to the Panel 2A during a loss of off-site power
Section C Facility and Radiation Monitoring Systems
Section C Facility and Radiation Monitoring Systems QUESTION C.19
[1.0 points]
Which ONE of the following figures best describes the operation of the inlet plenum siphon break when a rupture occurs in the inlet piping?
- a.
Figure 1
- b.
Figure 2
- c.
Figure 3
- d.
Figure 4
Section C Facility and Radiation Monitoring Systems
Section C Facility and Radiation Monitoring Systems
Section C Facility and Radiation Monitoring Systems
(***** END OF CATEGORY C *****)
(***** END OF EXAMINATION *****)
Section A L Theory, Thermo & Fac. Operating Characteristics A.01 Answer a
Reference:
Burn, R., Introduction to Nuclear Reactor Operations, © 1988, Sec 2.4.5, page 2-
- 29.
A.02 Answer:
c
Reference:
Burn, R., Introduction of Nuclear Reactor Operations, © 1988, Sec 4.2 A.03 Answer:
c
Reference:
P = P0 et/T = 50 kW
- e(60sec/-80sec) = 50 kW
- e-0.75 = 0.472
- 50 kW = 23.6 kW A.04 Answer:
d
Reference:
Burn, R., Introduction to Nuclear Reactor Operations, © 1988, Sec 2.5.3, page 2-
- 45.
A.05 Answer:
d
Reference:
Burn, R., Introduction to Nuclear Reactor Operations, © 1982, Sec 3.3.3, page 3-21.
reactor A = (Keff1-Keff2)/(Keff1*Keff2). (0.2-0.1)/(0.2*0.1) = 5 k/k reactor B = (Keff1-Keff2)/(Keff1*Keff2). (0.7-0.6)/(0.7*0.6) = 0.2381 k/k 5/0.2381 = 21 A.06 Answer:
d
Reference:
Burn, R., Introduction of Nuclear Reactor Operations, © 1988, Sec 3.3 A.07 Answer:
d
Reference:
Burn, R., Introduction to Nuclear Reactor Operations, © 1982, Page 4-21.
A.08 Answer b
Reference:
DOE Fundamentals Handbook Nuclear Physics and Reactor Theory Vol. 2 A.09 Answer:
b
Reference:
Nuclides and Isotopes N = A - Z 235-92 = 143 A.10 Answer:
a K eff = 1.03*0.84*0.96*0.88*1.96*x X= 1/1.4326 = 0.698
Reference:
Burn, R., Introduction of Nuclear Reactor Operations, © 1988, Sec 3.3
Section A L Theory, Thermo & Fac. Operating Characteristics A.11 Answer:
c
Reference:
Time is related to ratio of final power to initial power. 2:1 is the largest ratio.
A.12 Answer:
c
Reference:
Burn, R., Introduction to Nuclear Reactor Operations, © 1982, Sec 3.2.
A.13 Answer:
c
Reference:
Burn, R., Introduction of Nuclear Reactor Operations, © 1982, Figure 2.6, page 2-39 A.14 Answer:
c
Reference:
from k=0.955 to criticality (k=1), D = (k-1)/k = -0.047 Dk/k or D = 0.047 Dk/k needed to reach criticality. From criticality to JUST prompt, Dk/k = eff required, so minimum reactivity added to produce prompt criticality will be: 0.047+0.0078= 0.0548 A.15 Answer:
a
Reference:
Burn, R., Introduction to Nuclear Reactor Operations, © 1988, subcritical Multiplication process.
A.16 Answer:
d
Reference:
Burn, R., Introduction of Nuclear Reactor Operations, © 1982, Sec 3.3.1 A.17 Answer c
Reference:
Burn, R., Introduction to Nuclear Reactor Operations, © 1988, Sec 8.1 A.18 Answer:
c
Reference:
Burn, R., Introduction to Nuclear Reactor Operations, ©4.5, 1988 A.19 Answer:
c
Reference:
Chart of the Nuclides A.20 Answer:
a
Reference:
Burn, R., Introduction to Nuclear Reactor Operations, © 1982, Sec 7.6
Section B Facility and Radiation Monitoring Systems B.01 Answer:
c
Reference:
PM 1.3 and TS 7.1 B.02 Answer:
a (4), b (2), c (1), d (3)
Reference:
10 CFR B.03 Answer:
a(1) b(2) c(2) d(3)
Reference:
PM 1.4 B.04 Answer:
d
Reference:
PM 2.4, Step 3(a)
B.05 Answer:
d
Reference:
TS 4.2.9 B.06 Answer:
b
Reference:
10 CFR 20 B.07 Answer:
b
Reference:
TS 2.2 B.08 Answer:
c
Reference:
TS Definition, Frequency Not exceed: 25% of 2 years + 2 years = 6 months + 24 months = 30 months B.09 Answer:
a
Reference:
TS 3.7.1 B.10 Answer:
c
Reference:
EP 4.4.1.3
Section B Facility and Radiation Monitoring Systems B.11 Answer:
d
Reference:
Emergency Plan 4.3.2.1 B.12 Answer:
b
Reference:
6CEN = R/hr @ 1 ft. -> 6 x 1 x 1 x 1 = 6 R/hr at 1ft. I0D02 = I*D2 6 R/hr*(1 ft) 2 = 0.1 R/hr *D 2 D= sqrt(6/0.1) = 7.7 ft.
B.13 Answer:
a
Reference:
NRC Standard Questions B.14 Answer:
c
Reference:
10 CFR 20.1003 B.15 Answer:
b
Reference:
TS 3.3.3 B.16 Answer:
b
Reference:
NRC standard question B.17 Answer:
c
Reference:
10 CFR 50.74 B.18 Answer:
c
Reference:
PM 1.14.3 B.19 Answer:
d
Reference:
TS 6.3 B.20 Answer:
c
Reference:
T A = A*e -t 2Ci = 50Ci* e -(t)
Ln(2/50) = -ln2/5.27 yr*(t) --> -3.2189/-0.1315 solve for t: 24.47 years
Section C Facility and Radiation Monitoring Systems C.01 Answer:
d
Reference:
RSM 4.3 C.02 Answer:
d
Reference:
RSM 8.3.6 C.03 Answer:
c
Reference:
RSM 1.2 C.04 Answer:
a(2) b(3) c(4) d(1)
Reference:
RSM 9.3, 9.4 C.05 Answer:
b
Reference:
RSM 8.2.1 C.06 Answer:
a
Reference:
RSM 3.4.2 C.07 Answer:
b
Reference:
RSM 1.10, step 4.14B C.08 Answer:
b
Reference:
PM 5.2.14, Follow-up Action C.9 Answer:
b
Reference:
RSM, Figure 8.14, Emergency Power system Block Diagram C.10 Answer:
a(6) b(7) c(8) d(4) e(5) f(1) g(3) h(2) (0.25 each)
Reference:
RSM 5-3 and TS 4.3 C.11 Answer:
a
Reference:
SAR 6-4, page 6-4 and SAR, page 5-18 C.12 Answer:
c
Reference:
RSM 3.2.5
Section C Facility and Radiation Monitoring Systems C.13 Answer:
a
Reference:
PM 2.4.2 C.14 Answer:
a
Reference:
TS 3.3.6 C.15 Answer:
d
Reference:
RSM 3.7.1 C.16 Answer:
b
Reference:
RSM 5.2.1 C.17 Answer:
a
Reference:
TS 2.2, Figure 2.2-1 C.18 Answer:
d
Reference:
RSM, Emergency Power C.19 Answer:
a
Reference:
RSM, Coolant Systems