ML14192A757

From kanterella
Jump to navigation Jump to search

Forwards Safety Evaluation Accepting Util 831107 Response to Generic Ltr 83-28,Items 3.1.1,3.1.2,3.2.1,3.2.2,4.1 & 4.5.1 Re post-trip Review,Equipment Classification,Vendor Interface & post-maint Testing
ML14192A757
Person / Time
Site: Robinson 
Issue date: 03/20/1986
From: Requa G
Office of Nuclear Reactor Regulation
To: Utley E
CAROLINA POWER & LIGHT CO.
Shared Package
ML14192A758 List:
References
GL-83-28, TAC-52956, TAC-53092, TAC-53793, TAC-54103, NUDOCS 8604110560
Download: ML14192A757 (3)


Text

March 20, 1986 Docket No.:

50-261 DISTRIBUTION Docket File G. Requa NRC PDR C. Vogan Local PDR ACRS (10)

Mr. E. E. Utley PAD#2 Rdg Tech Branch Senior Executive Vice President T. Novak Gray File Power Supply and Engineering & Construction OELD Carolina Power and Light Company E. Jordan Post Office Box 1551 B. Grimes Raleigh,-North Carolina 27602 J. Partlow

Dear Mr. Utley:

Subject:

Generic Letter 83-28, Items 3.1.1, 3.1.2, 3.2.1, 3.2.2, 4.1 and 4.5.1, H. B. Robinson Steam Electric Plant, Unit No. 2 (TAC Nos.

52956, 53793, 53092, and 54103)

We have completed our review of your response to Generic Letter (GL) 83-28 dated November 7, 1983.

Your response was evaluated for compliance to the staff's positions delineated in Generic Letter 83-28 for Action Items 3.1.1, 3.1.2, 3.2.1, 3.2.2, 4.1, and 4.5.1. Your responses to items 3.1.1, 3.1.2, 3.2.1, 3.2.2, 4.1, and 4.5.1 were found to be adequate and meet the intent of GL 83-28. Therefore, these items are considered closed. The enclosed Safety Evaluation provides our evaluation of your responses.

The reporting and/or recordkeeping requirements of this letter affect fewer than ten respondents; therefore, OMB clearance is not required under P.L 96-511.

Sincerely, Glode Requa, Project Manager PWR Project Directorate #2 Division of PWR Licensing-A Office of Nuclear Reactor Regulation

Enclosure:

Safety Evaluation for Generic Letter 83-28 cc:

See next page PM:P G~e,~L ubenstein 3

3//g/86 8604110560 860320 PDR ADOCK 05000261I P

PDR

-1 vs~

RE&,,,

o UNITED STATES C)

NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 March 20, 1986 Docket No.: 50-261 Mr. E. E. Utley Senior Executive Vice President Power Supply and Engineering & Construction Carolina Power and Light Company Post Office Box 1551 Raleigh, North Carolina 27602

Dear Mr. Utley:

Subject:

Generic Letter 83-28, Items 3.1.1, 3.1.2, 3.2.1, 3.2.2, 4.1 and 4.5.1, H. B. Robinson Steam Electric Plant, Unit No. 2 (TAC Nos.

52956, 53793, 53092, and 54103)

We have completed our review of your response to Generic Letter (GL) 83-28 dated November 7, 1983. Your response was evaluated for compliance to the staff's positions delineated in Generic Letter 83-28 for Action Items 3.1.1, 3.1.2, 3.2.1, 3.2.2, 4.1, and 4.5.1. Your responses to items 3.1.1, 3.1.2, 3.2.1, 3.2.2, 4.1, and 4.5.1 were found to be adequate and meet the intent of GL 83-28. Therefore, these items are considered closed. The enclosed Safety Evaluation provides our evaluation of your responses.

The reporting and/or recordkeeping requirements of this letter affect fewer than ten respondents; therefore, OMB clearance is not required under P.L 96-511.

Sincerely, Glode Requa, Project Manag r PWR Project Directorate #2 Division of PWR Licensing-A Office of Nuclear Reactor Regulation

Enclosure:

Safety Evaluation for Generic Letter 83-28 cc:

See next page

Mr. E. E. Utley Carolina Power & Light Company H. B. Robinson 2 cc:

G. F. Trowbridge, Esquire Mr. Dayne H. Brown, Chief Shaw, Pittman, Potts and Trowbridge Radiation Protection Branch 1800 M Street, N.W.

Division of Facility Services Washington, DC 20036 Department of Human Resources P.O. Box 12200 Raliegh, North Carolina 27605 Mr. McCuen Morrell, Chairman Darlington County Board of Supervisors County Courthouse Darlington, South Carolina 29535 State Clearinghouse Division of Policy Development 116 West Jones Street Raleigh, North Carolina 27603 Attorney General Department of Justice Justice Building Raleigh, North Carolina 27602 U.S. Nuclear Regulatory Commission Resident Inspector's Office H. B. Robinson Steam Electric Plant Route 5, Box 413 Hartsville, South Carolina 29550 Regional Administrator, Region II U.S. Nuclear Regulatory Commission Suite 2900 101 Marietta Street Atlanta, Georgia 30303 Mr. R. Morgan General Manager H. B. Robinson Steam Electric Plant Post Office Box 790 Hartsville, South Carolina 29550