Approves 901005 Request for Temporary Waiver of Compliance & Forwards Tech Spec 3.5.3.3,Table 3.5.7
ML14191A501
Person / Time
Site: Robinson 
Issue date: 10/09/1990
From: Lainas G
Office of Nuclear Reactor Regulation
To: Eury L
Carolina Power & Light Co
References
TAC-77728 NUDOCS 9010240318
Download: ML14191A501 (4)


Text

October 9, 1990 Docket No. 50-261 Mr. Lynn W. Eury Executive Vice President Power Supply Carolina Power & Light Co.

Post Office Box 1551 Raleigh, North Carolina 27602

Dear Mr. Eury:

SUBJECT:

TEMPORARY WAIVER OF COMPLIANCE - H. B. ROBINSON STEAM ELECTRIC STATION, UNIT NO. 2 (TAC NO. 77728)

By letter dated October 5, 1990, you requested an emergency Technical Specification (TS) Amendment related to Technical Specification 3.5.3.3, Table 3.5-7, Items 3.a and 3.b, Required Action b. for the H. B. Robinson Steam Electric Station, Unit No. 2 (HBR-2). Your proposed emergency TS amendment would add a footnote to Action b. This proposed footnote would provide a one time change during Refueling Outage 13 to allow continued effluent releases (purging from the reactor containment vessel) with radiation monitors RMS-11 and RMS-12 and their associated backup monitors RMS-14 and RMS-34 out of service. The amendment would allow containment purging only with no fuel in containment and containment integrity not required.

We have reviewed the Request for Temporary Waiver of Compliance in your October 5, 1990, letter and find it acceptable. Therefore, we confirm the requested Temporary Waiver of Compliance, which was verbally granted on October 5, 1990. A marked-up TS 3.5.3.3, Table 3.5-7, Item 3.a and 3.b.

with the footnote for HBR-2 is enclosed. This Temporary Waiver of Compliance shall be effective immediately and shall remain in effect until the NRC staff completes processing of Carolina Power & Light Company's request for an emergency TS Amendment dated October 5, 1990.

Sincerely, Original Signed By:

Gus C. Lainas, Assistant Director for Region II Reactors Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Enclosure:

As stated cc: See next page Q

DISTRIBUTION 91'010240318 901009 epage DR ADOCK 05000261.1.

OFC

LA
PM:PDII-1
D:

1

ADR NAME :PA on
RLo:sw,

/ EAdensam

GL as DATE
Docm RECORD 0

/90

10/

/90

10/

/90 Document Name:

LTR W. EURY

TABLE 3.5-7 (Continued)

ENCLOSURE RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION Release PathwayInstrumentation MCO*

Required Action

3. Containment Vessel Via
b. Effluent releases via this Pathway May Coninue provided that Plant Vent (Continued) either of the Plant Vent Radonoble Gas Monitors (RM-14 or RS-34) is operable; otherwise, suspend all releases via this pathway.*
b.

Radioparticulate Monitor With the number of channels operable less than the MCO requirement:

(RMS-11) provides automatic

a. Exert best efforts to return the instrumets to operable status termination of containment within 30 days and, if unsuccessful, explain in the next Semi vessel releases exceeding annual Radioactive Effluent Release Report why the inoperabili alarm/trip setpoints was not corrected in a timely manner in accordance with Specification 6.9.1.d and,
b. Effluent releases via this pathway may continue provided that either of the Plant Vent Radionoble Gas Monitors (RMS-14 or RMS-34) is operable; otherwise, suspend all releases via this pathway.
c. Sampler flow rate monitor I

With the number of channels operable less than the MCO oequirement:

(RMS-11)

a. Exert best efforts to return the instruments to operable status within 30 days and, if unsuccessful, explain in the next Semi annual Radioactive Effluent Release Report why the inoperability was not corrected in a timely manner in accordance with Specification 6.9.1.d and,
b. Effluent releases via this pathway may continue provided that flow rate is estimated once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.
4. Condenser Vacuum Pump Vent

(.

a. Radionoble gas monitor I

With the number of channels operable less than the MCO requirement:

(RMS-15) diverts effluents

a. Exert best efforts to return the instruments to operable status nfrom Condenser Vacuum Pump within 30 days and, if unsuccessful, explain in the next Semi Vent to the Plant Vent upon annual Radioactive Effluent Release Report why the inoperability exceeding alarm/trip was not corrected in a timely manner in accordance with setpoint.

Specification 6.9.1.d and,

    • For one time only during Refueling Outage 13 with no fuel in the containment and containment integrity not required, effluent releases via this pathway may continue with RMS-14 and RMS-34 inoperable, provided that grab samples of the containment vessel atmosphere are taken once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and analyzed for radionoble gases within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

Mr. L. W. Eury H. B. Robinson Steam Electric Carolina Power & Light Company Plant, Unit No. 2 cc:

Mr. R. E. Jones, General Counsel Mr. Dayne H. Brown, Director Carolina Power & Light Company Department of Environmental, P. 0. Box 1551 Health and Natural Resources Raleigh, North Carolina 27602 Division of Radiation Protection P. 0. Box 27687 Raleigh, North Carolina 27611-7687 Mr. H. A. Cole Special Deputy Attorney General Mr. Robert P. Gruber State of North Carolina Executive Director P. 0. Box 629 Public Staff - NCUC Raleigh, North Carolina 27602 P. 0. Box 29520 Raleigh, North Carolina 27626-0520 U.S. Nuclear Regulatory Commission Mr. C. R. Dietz Resident Inspector's Office Manager, Robinson Nuclear Project H. B. Robinson Steam Electric Plant Department Route 5, Box 413 H. B. Robinson Steam Electric Plant Hartsville, South Carolina 29550 P. 0. Box 790 Hartsville, South Carolina 29550 Regional Administrator, Region II U.S. Nuclear Regulatory Commission Mr. Heyward G. Shealy, Chief 101 Marietta Street Bureau of Radiological Health Suite 2900 South Carolina Department of Health Atlanta, Georgia 30323 and Environmental Control 2600 Bull Street Mr. R. Morgan Columbia, South Carolina 29201 General Manager H. B. Robinson Steam Electric Plant P. 0. Box 790 Hartsville, South Carolina 29550