April 2, 1990 Docket No. 50-261 Mr. Lynn W. Eury Executive Vice President Power Supply Carolina Power & Light Company Post Office Box 1551 Raleigh, North Carolina 27602

Dear Mr. Eury:

SUBJECT:

INSERVICE INSPECTION RELIEF REQUESTS NO. 19 and 20 - H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 (TAC NO 72250)

By letter dated February 1, 1989, Carolina Power & Light Company (CP&L) requested relief from certain inservice examination requirements at H. B.

Robinson Steam Electric Plant, Unit No. 2. Specifically, CP&L requested relief from the examination requirements of Section XI of the ASME Code for certain items of the reactor vessel, the pressurize, steam generator cladding and the regeneration heat exchanger welds.

CP&L has stated that conformance with the Code requirements is impractical because of radiation exposure considerations. We have determined, pursuant to 10 CFR 50.55 a(g)(6)(i), that granting of relief is authorized by law, will not endanger life or property or the common defense and security, and is otherwise in the public interest. In makeing this determination, the staff has given due consideration to the burden upon the licensee that could result if the requirements were imposed on the facility. This letter grants the relief.

Enclosed is our related Safety Evaluation.

Sincerely, Lester L. Kintner/for Elinor G. Adensam, Director Project Directorate II-1 Division of Reactor Projects -

I/II Office of Nuclear Reactor Regulation cc w/enclosures.

See next page 9004110079 900402 PDR ADOCK 05000261 G:4 F:C

  • SEE PREVIOUS CONCURRENCES OFC
  • LA:PD21-1
  • PM:PD21-1
  • OGC P

------------ ---- -----I NAME :PAnderson RLo:dt CBarth Eensam DATE :3/6/90

3/6/90
3/15/90 4/Z-190 OFFICIAL RECORD COPY Document Name: MR. EURY

Mr. L. W. Eury H. B. Robinson Steam Electric Carolina Power & Light Company Plant, Unit No. 2 cc:

Mr. R. E. Jones, General Counsel Mr. Dayne H. Brown, Director Carolina Power & Light Company Department of Environmental, P. 0. Box 1551 Health and Natural Resources Raleigh, North Carolina 27602 Division of Radiation Protection P. 0. Box 27687 Raleigh, North Carolina 27611-7687 Mr. H. A. Cole Special Deputy Attorney General Mr. Robert P. Gruber State of North Carolina Executive Director P. 0. Box 629 Public Staff - NCUC Raleigh, North Carolina 27602 P. 0. Box 29520 Raleigh, North Carolina 27626-0520 U.S. Nuclear Regulatory Commission Mr. C. R. Dietz Resident Inspector's Office Manager, Robinson Nuclear Project H. B. Robinson Steam Electric Plant Department Route 5, Box 413 H. B. Robinson Steam Electric Plant Hartsville, South Carolina 29550 P. 0. Box 790 Hartsville, South Carolina 29550 Regional Administrator, Region II U.S. Nuclear Regulatory Commission Mr. Heyward G. Shealy, Chief 101 Marietta Street Bureau of Radiological Health Suite 2900 South Carolina Department of Health Atlanta, Georgia 30323 and Environmental Control 2600 Bull Street Mr. R. Morgan Columbia, South Carolina 29201 General Manager H. B. Robinson Steam Electric Plant P. 0. Box 790 Hartsville, South Carolina 29550