Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555 April 28, 1992 Docket No. 50-261 Mr. R. A. Watson Senior Vice President Nuclear Generation Carolina Power & Light Company P. 0. Box 1551 Raleigh, North Carolina 27602
Dear Mr. Watson:
SUBJECT:
SECOND TEN-YEAR INTERVAL HYDROSTATIC TEST PROGRAM, H. B. ROBINSON STEAM ELECTRIC PLANT, UNIT NO. 2 (TAC NO. M82217)
By letter dated November 15, 1991, you submitted a request for relief from certain hydrostatic testing requirements of Section XI of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code) for the H. B. Robinson Steam Electric Plant, Unit No. 2 (HBR-2). This relief request pertains to the Second Ten-Year Interval Inservice Inspection Program.
Although the second ten-year interval for HBR-2 expired in February 1992, the ASME Code permits you to complete the test program within one year of the expiration date. Your letter states that you intend to perform the tests during refueling outage No. 14 which is in progress.
We have completed the review of your request and our Safety Evaluation is enclosed. Our disposition of your relief requests is summarized as follows:
(1) Relief Request No. 1 is granted pursuant to 10 CFR 50.55a(a)(3)(i); the alternative examination would provide an acceptable level of quality and safety.
(2) Relief Request No. 2 has two items:
(a) Relief from IWC-5222(c) of the ASME Code is not required according to the later Editions of the ASME Code (Winter 1980 Addenda).
(b) Relief from the requirements of IWA-5244(b) of the ASME Code is granted pursuant to 10 CFR 50.55a(g)(6)(i).
The performance of the annulus leakage test is impractical at your facility and the imposition of this requirement would cause a burden that would not be compensated for by an increase in quality or safety.
(3) Relief Request No. 3 relates to the use of later Editions and Addenda to the ASME Code. We have approved the use of IWA-1320(e) 1986 Edition. With this approval, the relief is not needed.
,_9205070120 920428 PDR ADOCK ;05000261 P
PDR SC F LECETR S
-2 (4) Relief Request No. 4 is granted pursuant to 10 CFR 50.55a(g)(6)(i);
the ASME Code required hold-time and hydrostatic test pressure are impractical to perform at your facility. The alternative examination that you proposed provides adequate assurance of continued inservice integrity.
Sincerely, Orignal signed by:
Elinor G. Adensam, Director Project Directorate II-1 Division of Reactor Projects -
I/II Office of Nuclear Reactor Regulation
Enclosure:
Safety Evaluation cc:
See next page DISTRIBUTION:
_Docket_ ile NRC & Local PDRs PD21 Reading S. Varga G. Lainas E. Adensam R. Lo P. Anderson J. Wiggins, EMCB OGC J. Wiggins T. McLellan ACRS (10)
L. Reyes, RH
- See previous concurrence OFFICE LA:PDII -
_M:.PD 1-1
- OGC NAME PAnderso FRLo:dbW JHull EAnsam DATE 04/47/92 04/-13 /92 04/14/92 04/q 4/92 FILENAME: ROB82217.LTR
Mr. R. A. Watson H. B. Robinson Steam Electric Carolina Power & Light Company Plant, Unit No. 2 cc:
Mr. H. Ray Starling Mr. Dayne H. Brown, Director Manager - Legal Department Department of Environmental, Carolina Power & Light Company Health and Natural Resources P. 0. Box 1551 Division of Radiation Protection Raleigh, North Carolina 27602 P. 0. Box 27687 Raleigh, North Carolina 27611-7687 Mr. H. A. Cole Special Deputy Attorney General Mr. Robert P. Gruber State of North Carolina Executive Director P. 0. Box 629 Public Staff -
NCUC Raleigh, North Carolina 27602 P. 0. Box 29520 Raleigh, North Carolina 27626-0520 U.S. Nuclear Regulatory Commission Mr. C. R. Dietz Resident Inspector's Office Vice President H. B. Robinson Steam Electric Plant Robinson Nuclear Department Route 5, Box 413 H. B. Robinson Steam Electric Plant Hartsvillle, South Carolina 29550 P. 0. Box 790 Hartsville, South Carolina 29550 Regional Administrator, Region II U.S. Nuclear Regulatory Commission Mr. Heyward G. Shealy, Chief 101 Marietta Street Bureau of Radiological Health Suite 2900 South Carolina Department of Health Atlanta, Georgia 30323 and Environmental Control 2600 Bull Street Mr. Ray H. Chambers, Jr.
Columbia, South Carolina 29201 General Manager H. B. Robinson Steam Electric Plant P. 0. Box 790 Hartsville, South Carolina 29550