Text
UNITED STATES NULLEAR REGULATORY COMMISSION RFGION 11 J101 MA[
I IA St., N.W., SUITE 3100 ATLANTA GEORGIA 30303 In Reply Refer To:
JUN 1 5 1979 RII:PJK 50-261 Carolina Power and Light Company ATTN:
J. A. Jones, Executive Vice President and Chief Operating Officer 411 Fayetteville Street Raleigh, North Carolina 27602 Gentlemen:
Subject:
Confirmation of Action This refers to my telephone conversation of June 15, 1979, with Mr. J. A.
Jones, Executive Vice President, regarding the indicated cracking in welds of the main feedwater piping system of the Robinson facility.
With regard to matters discussed, it is our understanding that your Robinson Nuclear Plant will not be returned to power operation without the concurrence of this office. Our concurrence will be based on a presentation to the NRC staff of the following:
- 1.
The results of your technical evaluation of the cause(s) of the defects in the feedwater piping.
- 2.
The corrective actions taken or to be taken to prevent recurrence of these or similar defects'in the feedwater piping systems.
Additionally, please provide for our analysis a representative sample of the defective area of one transition piece.
Please inform us imediately if your understanding of these items is different from that stated above.
Sincerely, ames P. O'Reil I. rector cc-fl.-R-Banks Manager, Nuclear Operations 411 Fayetteville Street Raleigh, North Carolina 27602 R. B. Starkey, Plant Manager P. 0. Box 790 Hartsville, South Carolina 29550 7907810579